HomeMy WebLinkAbout!Binder1_Plumbing1. THE PLUMBING SYSTEM DESIGN, INSTALLATION AND MATERIALS SHALLCONFORM TO THE PLUMBING CODE AND AUTHORITIES HAVINGJURISDICTION. IN CASE OF CONFLICTS WITH CODES, DRAWINGS, ORSPECIFICATIONS, THE MOST STRINGENT SHALL PREVAIL.2. BEFORE COMMENCEMENT OF WORK, THE CONTRACTOR SHALL VERIFYTHE EXACT LOCATIONS, ELEVATIONS AND CHARACTERISTICS OF ALLUTILITIES AND PIPING, AND SHALL IMMEDIATELY NOTIFY THE ARCHITECTOF ANY DISCREPANCIES.3. THESE DRAWINGS DO NOT INCLUDE ALL NECESSARY SAFETYREQUIREMENTS. CONTRACTOR TO COMPLY TO THE SAFETYREQUIREMENTS SET FORTH BY THE LOCAL AUTHORITIES HAVINGJURISDICTION.4. THESE DRAWINGS ARE FOR BIDDING PURPOSES ONLY. THEY AREESSENTIALLY DIAGRAMMATIC TO THE EXTENT THAT MANY OFFSETS,BENDS, UNIONS, SPECIFIC FITTINGS AND EXACT LOCATIONS ARE NOTINDICATED.5. ALL PLUMBING WORK SHALL BE INSTALLED SO AS TO AVOIDINTERFERENCE WITH ELECTRICAL EQUIPMENT, MECHANICAL EQUIPMENTAND STRUCTURAL FRAMING, SKYLIGHTS, ETC.6. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILINGACCESS PANELS WITH THE ARCHITECTURAL REFLECTED CEILING PLANAND ELECTRICAL LIGHTING PLAN.7. COORDINATE ALL LOCATIONS, SIZES AND ELEVATIONS OF ALL SLEEVESTHROUGH WALLS, BEAMS, SLABS AND FOOTING WITH STRUCTURAL ANDARCHITECTURAL DRAWINGS. ALL PIPES SLEEVING THROUGH BEAMS ORFOOTINGS SHALL HAVE A SLEEVE DIAMETER OF TWO PIPE SIZES OVERTHE PIPE PASSING THROUGH THE FOOTING OR PER STRUCTURALDRAWING. THE MOST STRINGENT SHALL PREVAIL.8. BEFORE FABRICATION OR INSTALLATION, THE CONTRACTOR SHALL VERIFY EXACT LOCATIONS OF ALL MECHANICAL/PLUMBING EQUIPMENT AND EQUIPMENT PROVIDED UNDER ANOTHER SECTION OF SPECIFICATIONS. EXACT ROUGH-IN LOCATIONS AND REQUIREMENTS SHALL BE COORDINATED IN FIELD.9. PIPING SUPPORTS. ALL PIPING TO BE SUPPORTED WITH HANGERS ANDBRACKETS WHICH PROVIDE ISOLATION FROM FRAMING. CONTACTBETWEEN PIPE AND SUPPORT TO BE LINED WITH PLASTIC OR FELT.10. ALL FLOOR AND WALL PENETRATIONS MUST BE SEALED WATERTIGHT AND VERMIN PROOF.11. EXACT LOCATIONS AND MOUNTING HEIGHTS OF PLUMBING FIXTURESSHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS.12. SEE ARCHITECTURAL DRAWINGS FOR HANDICAP FIXTURE LOCATIONS AND MOUNTING HEIGHTS. INSULATE ALL EXPOSED HOT WATER AND DRAIN PIPING BELOW HANDICAP LAVATORIES AND SINKS WITH INSULATING WRAP AND OFFSET P-TRAP AGAINST WALL. ALL FLUSH VALVES FOR HANDICAP SHALL BE LOCATED ON HANDICAP WHEELCHAIR ACCESS SIDE OF STALL.13. ALL CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE. THECONTRACTOR SHALL COORDINATE ALL CLEANOUT LOCATIONS OFEQUIPMENT, CABINETS, ETC., WITH THE ARCHITECT PRIOR TO ANYINSTALLATION.14. ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS OR OTHEREQUIPMENT SHOWN IN WALLS OR ABOVE NON-ACCESSIBLE CEILINGSSHALL BE INSTALLED BEHIND AN ACCESS PANEL. COORDINATELOCATION AND SIZE WITH ARCHITECT.15. PLUMBING CONTRACTOR SHALL COORDINATE COMPLETE PLUMBINGINSTALLATION AND REQUIREMENTS PRIOR TO SUBMITTING BID WITH ALLLOCAL DISTRICTS AND GOVERNING AUTHORITIES. INCLUDE ALL FINDINGSWITHIN THE BASE BID.16. ALL DRY SYSTEM PIPING SHALL BE INSTALLED WITH PROPER PITCH FORDRAINING OF SYSTEM.17. DO NOT SHUT DOWN ANY SYSTEM WITHOUT BUILDING OWNER'S PRIOR WRITTEN APPROVAL. FOLLOW ALL OWNER REQUIREMENTS AND SHUT DOWN PROCEDURES AS WELL AS ALL REQUIREMENTS OF THIS PROJECT'S CONTRACT DOCUMENTS (PLANS AND SPECIFICATIONS).18. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ROOF WORKTHAT IS REQUIRED AS PART OF THIS CONTRACT. ALL ROOF WORKSHALL BE PERFORMED SUCH THAT ALL EXISTING ROOF WARRANTEESARE MAINTAINED.19. PROVIDE ALL WORK IN COMPLIANCE WITH ALL LOCAL, STATE ANDFEDERAL CODES. OBTAIN ALL REQUIRED PERMITS. COORDINATE ALLWORK WITH LOCAL FIRE MARSHAL.20. FIELD VERIFY EXACT LOCATION, COMPOSITION AND CONDITION OF ALLPIPING, VALVES AND SYSTEMS AS REQUIRED FOR WORK OF THECONTRACT.21. PROVIDE ALL REQUIRED EXCAVATION, BACKFILL AND COMPACTION FORALL UNDERGROUND WORK.22. REFER TO ARCHITECTURAL DRAWINGS AND THE PROJECT SPECIFICATIONS FOR PROJECT PHASING REQUIREMENTS.23. WHERE PIPING IS LOCATED OVER FOOTINGS AND/OR OTHERUNDERGROUND STRUCTURES, ROLL DOWN AS REQUIRED TO CONNECT TO SYSTEMS NOTED. PROVIDE ALL REQUIRED OFFSETS, FITTINGS ANDCONNECTIONS.24. PROVIDE BALANCING VALVE ARRANGEMENTS AT EACH LOCATION WHERE MULTIPLE RISERS OR HORIZONTAL LOOPS INTERSECT.25. PITCH ALL SANITARY/WASTE, INDIRECT WASTE AND STORM PIPING AS FOLLOWS: PIPING 2 1/2" AND SMALLER, PITCH AT 2 PERCENT (1/4" PER FOOT) MINIMUM,PIPING 4" AND LARGER, PITCH AT 1 PERCENT (1/8" PER FOOT) MINIMUM.26. SUBMITTALS AND SHOP DRAWINGS: AS SOON AS POSSIBLE AND WITHIN21 DAYS AFTER AWARD OF THE CONTRACT, AND BEFORE THEIRPURCHASE, THE CONTRACTOR SHALL SUBMIT TO THE ARCHITECT 6BOUND BOOKLETS FOR APPROVAL AND CONTAINING A COMPLETE LISTOF MATERIALS, SPECIALTIES AND EQUIPMENT HE IS TO FURNISH FORTHE INSTALLATION. ALL SUBMITTALS SHALL BE MADE AT ONE TIME. NODEVIATION OF PLUMBING FIXTURES WILL BE ACCEPTED. BASED ONAPPROVAL OF ALTERNATE PRIOR TO BID.27. COORDINATE PLUMBING SYSTEMS WITH WORK OF ALL OTHER TRADESPRIOR TO ANY FABRICATION OR INSTALLATION.28. COORDINATE LOCATIONS OF ALL ROOF OPENINGS WITH STRUCTURAL,MECHANICAL, AND ARCHITECTURAL PLANS PRIOR TO ANY INSTALLATION.29. COORDINATE ALL VENT TERMINATIONS ABOVE ROOF WITH HVACCONTRACTOR. ALL VENT TERMINATIONS ABOVE ROOF SHALL BE AMINIMUM 25'-0" (HEALTHCARE) AWAY FROM ANY HVAC OUTSIDE AIR INTAKE (ROOFTOP UNIT, LOUVER, ETC). OR AT LEAST 3 FEET ABOVE WINDOW, DOOR, OPENING, AIR INTAKE OR VENT SHAFT.30. PROVIDE HOSE BIBB (HB) UNDER LAVATORY IN ALL TOILET ROOMSWITH FLOOR DRAINS.31. PROVIDE SCHEDULE 40 BLACK STEEL PIPE SLEEVES FOR ALLUNDERGROUND PIPING PASSING THROUGH OR UNDER FOOTINGS, WALLS,FOUNDATION WALLS, SLABS FLOORS AND/OR UNDERGROUND STRUCTURES. REFER TO THE PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.32. PLATFORMS, CURBS, AND FLUSHINGS FOR PLUMBING EQUIPMENT SHALLBE AS INDICATED ON THE STRUCTURAL AND ARCHITECTURAL PLANS,UNLESS NOTED OTHERWISE, COORDINATE EXACT SIZES OF REQUIREDOPENINGS AND SUPPORTS FOR FURNISHED EQUIPMENT.33. MAINTENANCE LABEL SHALL BE AFFIXED TO ALL PLUMBING EQUIPMENTAND A MAINTENANCE MANUAL SHALL BE PROVIDED TO OWNER'SREPRESENTATIVE WITH A COPY PROVIDED TO BUILDING COMMISIONING AGENT AND INCLUDED IN PROJECT O&M MANUAL SUBMISSION AT COMPLETION OF PROJECT.34. ALL HOSE BIBBS, WALL HYDRANTS AND MOP SERVICE BASINS SHALLBE EQUIPPED WITH APPROVED, PROPERLY INSTALLED ATMOSPHERIC TYPEVACUUM BREAKERS.35. COORDINATE WITH ELECTRICAL TRADE PRIOR TO ORDERING ELECTRICALLY OPERATED EQUIPMENT FOR AVAILABLE VOLTAGES AT EQUIPMENTLOCATIONS.36. PIPE SIZE DISCREPANCIES BETWEEN FLOOR PLANS AND RISER DIAGRAMSLARGER PIPE SIZE INDICATED WILL TAKE PRECEDENCE.37. THESE PLANS INDICATE APPROXIMATE ROUGH-INS ONLY FOR EQUIPMENTNOT IN THIS SECTION (N.I.T.S.) EXACT ROUGH-IN DIMENSIONS MUST BEOBTAINED FROM THE EQUIPMENT MANUFACTURER.38. ALL VALVES, UNIONS, ETC. TO BE SAME SIZE AS PIPE UNLESSOTHERWISE INDICATED ON DRAWINGS.39. UNIONS SHALL BE PROVIDED AND INSTALLED AFTER EACH SCREW-TYPEVALVE AND PRIOR TO EQUIPMENT CONNECTIONS.40. THE PLUMBING CONTRACTOR SHALL COORDINATE ALL REQUIREMENTSFOR ALL POINTS OF CONNECTION WITH THE GENERAL CONTRACTOR ANDOTHER TRADES PRIOR TO BID.41. CONTRACTOR SHALL PROVIDE ALL VALVES AND BACKFLOW PREVENTIONDEVICES AS REQUIRED BY STATE AND LOCAL CODES.42. DRAINS SHALL BE INSTALLED AT THE LOW POINT OF THE FLOORS,UNLESS OTHERWISE NOTED.43. OFFSETS IN PIPING AROUND OBSTRUCTIONS SHALL BE PROVIDED AT NOADDITIONAL COST TO THE OWNER.44. PROVIDE RPZ TYPE BACKFLOW PREVENTER AND ISOLATION VALVES ONALL MAKE-UP WATER LINES EQUAL TO WATTS LF909 (SAME SIZE AS LINE).COORDINATE WITH MECHANICAL DRAWINGS. PROVIDE CAP DOWNSTREAMOF RPZ FOR HVAC CONTRACTOR. MOUNT DEVICE AS HIGH ASPOSSIBLE. PROVIDE DRAIN FROM RPZ'S RELIEF VALVE ANDTERMINATE AT NEAREST FLOOR DRAIN.45. PROVIDE CLEAN-OUTS AT THE BASE OF ALL STORM, SANITARY, ANDWASTE STACKS.46. MINIMUM SIZE OF SANITARY/WASTE PIPING BELOW SLAB SHALL BE 3".47. PROVIDE FLOOR DRAIN TRAP SEALER ON ALL FLOOR DRAINS ASSPECIFIED.48. COORDINATE AND SCHEDULE WORK AND SHUTDOWNS WITH THE OWNERAND OTHER TRADES PRIOR TO DEMOLITION.49. PLUMBING SYSTEMS AND ALL COMPONENTS THAT ARE DESIGNED AND/ORINTENDED TO DELIVER POTABLE WATER FOR HUMAN CONSUMPTION SHALL BE THIRD-PARTY TESTED AND CERTIFIED FOR NOT EXCEEDING THE MAXIMUM ALLOWABLE LEAD CONTENT PER THE NSF/ANSI 372 STANDARD.50. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THEEQUIPMENT MANUFACTURER'S RECOMMENDATIONS AND APPLICABLECODES, PROVIDE ALL FITTINGS, VALVES, AND OTHER DEVICES REQUIREDFOR A COMPLETE WORKABLE INSTALLATION.51. INSTALL PIPING SO THAT ALL VALVES, STRAINERS, UNIONS, TRAPS,FLANGES AND OTHER APPURTENANCES REQUIRING ACCESS AREACCESSIBLE.52. PROVIDE CUTTING, CORING AND PATCHING OF ALL WALLS, SLABS ANDDECKS AS REQUIRED FOR WORK SHOWN. COORDINATE ALL WORK WITHOWNER AND GENERAL CONTRACTOR.53. PIPES SHALL BE SUPPORTED AND BRACED PER SMACNA "GUIDELINESFOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEMS AND PLUMBINGPIPING SYSTEMS."GENERAL NOTES:GENERAL SITE/UTILITY NOTES:1. THE PLUMBING CONTRACTOR SHALL PROVIDE THE WATER, SEWER ANDSTORM DRAIN SYSTEMS TO A POINT OF CONNECTION 5'-0" OUTSIDE OFTHE BUILDING AND SHALL MEET THE INVERT ELEVATION SHOWN ON THECIVIL DRAWINGS. PIPING BEYOND THIS POINT IS SPECIFIED UNDERANOTHER SECTION OF THE SPECIFICATION AND SHALL BE AS SHOWNON THE CIVIL DRAWINGS.2. THE CONTRACTOR SHALL MAKE ALL ARRANGEMENTS WITH UTILITYCOMPANIES FOR SERVICE AND CONNECTION AND SHALL MAKEAPPLICATION FOR SERVICE AND PERMITS IN THE NAME OF THE OWNERAND SHALL PAY ALL FEES AND CHARGES INCLUDING THE COST OFVAULTS AND METERS. CONTRACTOR SHALL MAKE VARIATIONS PER UTILITYCOMPANY'S REQUIREMENTS WITHOUT CHARGING EXTRA TO THE BIDCONTRACT.3. ALL EXTERIOR GAS COCKS, WATER SHUTOFF VALVES AND/OR SEWERCLEAN OUTS BELOW GROUND SHALL BE INSTALLED IN YARD BOXESWITH THE COVERS CONSPICUOUSLY MARKED "GAS", "WATER", AND"SEWER" RESPECTIVELY.4. CONNECT TO SITE PIPING OUTSIDE BUILDING AS SHOWN. PROVIDE ALLREQUIRED OFFSETS, FITTINGS AND CONNECTIONS. FIELD VERIFY EXACTLOCATION, DEPTH AND COMPOSITION OF SITE SERVICES ANDCOORDINATE ALL WORK WITH SITE CONTRACTOR.5. FIELD VERIFY ALL UNDERGROUND VALVES AND PIPING AS REQUIRED FORWORK SHOWN.6. WATER OR WASTE PIPE BELOW GRADE OUTSIDE THE BUILDING SHALLHAVE MINIMUM COVER AS RECOMMENDED BY LOCAL AUTHORITIES.7. NO GAS PIPING SHALL BE INSTALLED IN OR ON THE GROUND UNDERANY BUILDING OR STRUCTURE AND ALL EXPOSED GAS PIPING SHALL BEKEPT AT LEAST 6" ABOVE GRADE.WHHBTSFSGIWAWAVSYMBOLACID WASTE PIPING (AW)ACID VENT PIPING (AV)NATURAL GAS PIPING (G)INDIRECT WASTE PIPING (IW)SANITARY/WASTE PIPING (SAN/W)VENT PIPING (V)DESCRIPTIONAGWO2N2VACVACUUM PIPING (VAC)NITROGEN PIPING (N2)OXYGEN PIPING (O2)GREASY WASTE PIPING (GW)COMPRESSED AIR PIPING (A)VALVE WITH TAMPER SWITCHFLOW SWITCHWALL HYDRANTHOSE BIBBTHERMOMETERCLEANOUT (CO)PLUMBING SYMBOLS LISTREMOVE TO THIS POINTNEW TO EXISTING CONNECTIONEXISTING PIPINGWORK TO BE REMOVEDHW RECIRCULATION PIPING (HWR)HOT WATER PIPING (H)COLD WATER PIPING (C)STORM PIPING (ST)P-TRAPDROP CONNECTIONELBOW UP, ELBOW DOWNUNIONCAP OR PLUGCHECK VALVESHUT OFF VALVEBALANCE VALVEPRESSURE GAGESTRAINERBACKFLOW PREVENTERFLOOR DRAIN (FD)SOLENOID VALVEREGULATING VALVEPIPE CONTINUATION (SINGLE LINE)PIPE CONTINUATION (DOUBLE LINE)BUTTERFLY VALVEMETERMROOF DRAIN (RD)PUMPPRESSURE REDUCING VALVEHCHWRVSTWVENT THROUGH ROOF (VTR)LIQUEFIED PETROLEUM GAS PIPING (LPG)LPGVTRDECKPLATE CLEANOUT (DPCO)NOTE: NOT ALL SYMBOLS ARE NECESSARILY USED SYMBOL DESCRIPTIONFILTERED COLD WATER PIPING (FC)FCNOTES:THE PROJECT IS DESIGNED UNDER THE 2020 NYS STRETCH CODES, 2020 NYS IECC, ASHRAE 90.1-2006, ITHACA GREEN BUILDING POLICY INITIATIVE,WELL BUILDING DESIGN CRITERIA VERSION 2, LEED VERSION 4.1, BASE TAX ABATEMENT AND ENHANCED ENERGY ABATEMENT AS WELL AS THE 2018 FGI REQUIREMENTS FOR OUTPATIENT FACILITIES.INCLUSIVE OF THE PROGRAMS LISTED ABOVE, LEED AND WELL BUILDING CREDITS ARE BEING PURSUED THAT SPECIFICALLY IMPACT THE PLUMBING SCOPE. PIPING MATERIAL, WATER QUALITY, HOT WATER HEATER EFFICIENCY, LEGIONELLA CONTROL, WATER SENSE FIXTURES, FIXTURE WATER CONSUMPTION, ENERGY STAR EQUIPMENT, ETC. CONTRACTOR TO REVIEW ALL REQUIREMENTS PRIOR TO BID, ALL EQUIPMENT AND MATERIALS TO MEET OR EXCEED THE REQUIREMENTS OF THE PROGRAMS LISTED.THIS PROJECT WILL BE COMMISSIONED. REFERENCE SPECIFICATION SECTIONS 220800 AND 019113 FOR COMMISSIONING REQUIREMENTS.REQUIRED 2020 IECC ENERGY CONSERVATION COMPLIANCECODE SECTIONCOMPLIANCEC303.3 OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO OWNER BY CONTRACTOR FOR ALL EQUIPMENTC401.2 BUILDING COMPLIES WITH THE APPLICABLE SECTIONS OF CODE BASED ON METHOD 2C402.5 REFERENCE ARCHITECTURAL PLANS FOR AIR LEAKAGE CRITERIA C403.2.1HVAC LOAD SIZING HAS BEEN PERFORMED IN THE CARRIER HAP PROGRAM, USING RTS (HEAT BALANCE) METHODOLOGYC403.2.3 ALL HVAC EQUIPMENT MEETS OR EXCEEDS MINIMUM EFFICIENCIES, REFERENCE MECHANICAL DOCUMENTSC403.2.4 REQUIRED HVAC CONTROLS SHALL BE PROVIDED, REFERENCE MECHANICAL DOCUMENTSC403.2.4.3MOTORIZED DAMPERS PROVIDED FOR EXHAUST AND OUTSIDE AIR INTAKES GREATER THAN 300 CFM OR IN BUILDINGS 3 STORIES OR LESSC403.2.9.1 DUCT IS REQUIRED TO BE INSULATED TO THE INDICATED MINIMUM LEVEL, REFERENCE MECHANICAL DOCUMENTSC403.2.9.3 INSTALLING CONTRACTOR SHALL ENSURE THAT ALL AIR DISTRIBUTION COMPONENTS ARE PROPERLY SEALEDC403.2.9.5 DUCT SIZING AND DUCT DESIGN HAS BEEN PERFORMED, REFERENCE MECHANICAL DOCUMENTSC403.2.10 ALL PIPING INSULATION CRITERIA HAS BEEN MET, REFERENCE MECHANICAL / PLUMBING DOCUMENTSC403.2.11 MECHANICAL SYSTEMS SHALL BE COMMISSIONED AS REQUIREDC404.2 ALL WATER HEATING EQUIPMENT MEETS OR EXCEEDS MINIMUM EFFICIENCIES, REFERENCE PLUMBING DOCUMENTSC404.4 ALL DOMESTIC HOT WATER PIPING INSULATION CRITERIA HAS BEEN MET, REFERENCE PLUMBING DOCUMENTSC405.2 LIGHTING CONTROL CRITERIA HAS BEEN MET, REFERENCE ELECTRICAL DOCUMENTSC405.5 EXTERIOR LIGHTING TOTAL POWER DOES NOT EXCEED THE ALLOWANCE, REFERENCE ELECTRICAL DOCUMENTSC405.6 ELECTRICAL POWER HAS BEEN PROVIDED PER THE CODE REQUIREMENTS, REFERENCE ELECTRICAL DOCUMENTSC408.2.2 INSTALLING CONTRACTOR SHALL TEST AND BALANCE ALL HVAC SYSTEMS AND PROVIDE REPORT TO ENGINEERMECHANICAL DESIGN CONFORMS TO 2020 IECC AND IMC CODE REQUIREMENTSC103.2.1REFERENCE ARCHITECTURAL PLANS FOR FENESTRATION U-FACTORS AND SOLAR HEAT GAIN COEFFICIENTSREFERENCE ARCHITECTURAL PLANS FOR AREA-WEIGHTED U-FACTORS AND SOLAR HEAT GAIN COEFFICIENTSC103.2.2C103.2.3C103.2.4C103.2.5C103.2.6C103.2.7C103.2.8C103.2.9C103.2.10C103.2.11C103.2.12REFERENCE MECHANICAL AND PLUMBING DOCUMENTS FOR DUCT AND PIPE INSULATION MATERIALS, ARCHITECTURAL DOCUMENTS FOR ALL OTHER INSULATION MATERIALSREFERENCE MECHANICAL AND PLUMBING DOCUMENTS FOR EQUIPMENT TYPES, SIZES AND EFFICIENCIESREFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENT TYPES, SIZES AND EFFICIENCIESREFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENTAMD SYSTEM CONTROLSREFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENT HORSEPOWER AND CONTROLSREFERENCE MECHANICAL AND PLUMBING SPECIFICATIONS FOR SEALING AND INSULATION LOCATIONSREFERENCE ELECTRICAL DOCUMENTS FOR LIGHTING FIXTURE SCHEDULE AND CONTROLSREFERENCE ELECTRICAL DRAWINGS FOR DAYLIGHTING ZONESREFERENCE MECHANICAL SPECIFICATIONS FOR AIR SEALING DETAILS803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:05:43 PMP001LEGEND &GENERALNOTES02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGTO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGMENT, THE PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE INTERNATIONAL ENERGY CODE, AS ADOPTED BY THE STATE.ENERGY CONSERVATION CODE COMPLIANCE STATEMENTREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 REF.12345ABCE3.8F3.914W3W5W67867W8113"1273"3"W888107123"3"8"867WV2"74"4"4"1313131313W1W3"98586764"4"4"5WW5W84"4"8764"WW3"3"888888884"4"4"7252228876884"8103"8567124"4"3"84"4"3"4"10104"8"8"V2"4"134"4"W74"154"1554168"6"STST6"STSTST4"ST4"14144"6"6"8"8"4186"17555VESTIBULE100V2LOBBY/WAITING101LOBBY/WAITING101RECEPTION101BTRIAGE/INTERVIEW106CLEANHOLDING107STAFFBREAK102STAFFTOILET103SHAREDPROVIDEROFFICE104PoSPATIENTTOILET105CSUB-WAITING105BEXAM114EXAM115EXAM116TREATMENT117STORAGE144MECHANICAL145WATERSERVICE146CIRCULATION105EXAM118RADIOLOGY(X-RAY)119EXAM113EXAM112EXAM121EXAM120SOILEDWORK111MAINSERVER140BUILDINGMAINTENANCETOILET/SHOWER138AEMERGENCYEQUIPMENTROOM141MAINELECTRICAL142SUPPLYCHAINAREA138EVSSUPPLY&EQUIPMENT139BLOODDRAW130BLOODDRAW129BLOODDRAW(PoS)128CORRIDOR122CLEANLINENHOLDING137WASTEHOLDING136STAFFBREAK133CLEANSUPPLY134STAFFTOILET131LABORATORY126REGISTRATION124WAITING/CIRCULATION123MAINLOBBY100EVS125PUBLICTOILET100APUBLICTOILET100BMAINLOBBY100CORRIDOR122CIRCULATION105STATLAB/MED110VITALSALCOVE105AVESTIBULE100V1CORRIDOR143CORRIDOR14358"8"4"4"24"W4"W3"3"4"2"4"134"3"803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:05:56 PMP100FOUNDATONPLAN02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1FOUNDATION PLANNDRAWING NOTES:1ELEVATOR SUMP PUMP (ESP-1). REFER TO DETAIL DRAWING(S).24" SANITARY/WASTE UP.3CONNECT 8" SANITARY SEWER TO 8" BY CIVIL CONTRACT AT INVERT -5.00'.4SLEEVE AND SEAL.5UP TO DECK PLATE CLEANOUT.64" SANITARY UP TO WATER CLOSET.72" VENT UP.81 1/2" WASTE UP TO SINK/LAVATORY. INCREASE TO 3" WASTE ON ALL UNDERGROUND HORIZONTAL RUNS.91 1/2" WASTE UP TO ELECTRIC WATER COOLER. INCREASE TO 3" WASTE ON ALL UNDERGROUND HORIZONTAL RUNS.101 1/2" WASTE UP TO BOTTLE FILLER. INCREASE TO 3" WASTE ON ALL UNDERGROUND HORIZONTAL RUNS.111 1/2" WASTE UP TO BACK-TO-BACK SINKS/LAVATORIES. CONNECT 1 1/2" WASTE TO EACK SINK/LAVATORY. INCREASE TO 3" WASTE ON ALL UNDERGROUND HORIZONTAL RUNS.123" WASTE (WITH TRAP) UP TO MOP SERVICE SINK.134" WASTE (WITH TRAP) UP TO FLOOR DRAIN.FEE = 0.00'144" STORM (PRIMARY SYSTEM) UP.156" STORM (PRIMARY SYSTEM) UP.16CONNECT 8" STORM TO 8" BY CIVIL CONTRACT AT INVERT -5.00'.176" COMBINED WATER SERVICE UP.18CONNECT 6" COMBINED WATER SERVICE TO 6" BY CIVIL CONTRACT.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 REF.12345ABCE3.8F3.9WASTEHOLDING136STAFFBREAK133SOILED132CLEANSUPPLY134REGISTRATION124PUBLICTOILET100AEVS109EXAM121EXAM120SOILEDWORK111EXAM112EXAM115EXAM114PoSPATIENTTOILET105CCLEANLINENHOLDING137TRIAGE/INTERVIEW106STAFFTOILET103EXAM116STORAGE144WATERSERVICE146SUPPLYCHAINAREA138EVSSUPPLY&EQUIPMENT139EXAM118MAINELECTRICAL142EMERGENCYEQUIPMENTROOM141MAINSERVER140VESTIBULE100V2VESTIBULE100V1HOLDING/MAIL100CCIRCULATION105CIRCULATION105VITALSALCOVE105ASUB-WAITING105BSTAIR2ST2-1CIRCULATION105CORRIDOR122SPECIMENTOILET127BLOODDRAW130BLOODDRAW129BLOODDRAW(PoS)128WAITING/CIRCULATION123CORRIDOR135LABORATORY126STAFFTOILET131MAINLOBBY100EVS125CORRIDOR143TREATMENT117EXAM113STATLAB/MED110CLEANHOLDING107SHAREDPROVIDEROFFICE104STAFFBREAK102BUILDINGMAINTENANCETOILET/SHOWER138A2DPCO4" FD-A4" FD-A4" FD-A 4" FD-A1212112DPCODPCODPCODPCODPCOW651 1/2"W44WWWW4441 1/2"2"1 1/2"2"1 1/2"1 1/2"2"1 1/2"4442"441 1/2"4101041 1/2"61 1/2"1 1/2"2"410441144W3"WW73"34"4"431043104" FD-ADPCODPCOW1 1/2"2"1 1/2"2"1 1/2"2"2"W1 1/2"444448833223104"1 1/2"34"4"4"4"4"S T 1418121314181913204"4"4"ST6"6"916181715318176"6"STST1621224" FD-ADPCODPCODPCODPCODPCO4"2"4"4"4"2"1 1/2"31 1/2"24"4" FD-A4"4"803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:06:08 PMP101FIRST FLOORPLAN -SANITARY/WASTE ANDSTORM02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1FIRST FLOOR PLAN - SANITARY/WASTE AND STORMDRAWING NOTES:124" SANITARY/WASTE DOWN.34" SANITARY/WASTE UP. GENERAL NOTES:1. PROVIDE WALL PLATE CLEANOUTS OR CLEANOUT TEES AT THE BASE OF ALL SANITARY/WASTE AND STORM STACKS.2. COORDINATE SANITARY/WASTE OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.41 1/2" WASTE UP TO SINK/LAVATORY. 51 1/2" WASTE UP TO ELECTRIC WATER COOLER. 61 1/2" WASTE UP TO BOTTLE FILLER.73" WASTE (WITH TRAP) UP TO MOP SERVICE SINK.82" WASTE (WITH TRAP) UP TO SHOWER.9104" SANITARY UP TO WATER CLOSET.2" VENT UP.111 1/2" WASTE UP TO BACK-TO-BACK SINKS/LAVATORIES. CONNECT 1 1/2" WASTE TO EACH SINK/LAVATORY.124" STORM STACK (PRIMARY SYSTEM) UP AND DOWN.134" STORM (SECONDARY SYSTEM) UP.14TERMINATE 4" STORM (SECONDARY SYSTEM) AT BUILDING'S EXTERIOR WITH ZURN ZARB199 DOWNSPOUT NOZZLE ON FACE OF BUILDING.15166" STORM (SECONDARY SYSTEM) UP.17TERMINATE 6" STORM (SECONDARY SYSTEM) AT BUILDING'S EXTERIOR WITH ZURN ZARB199 DOWNSPOUT NOZZLE ON FACE OF BUILDING.18SLEEVE AND SEAL.194" STORM (PRIMARY SYSTEM) UP.204" STORM (PRIMARY SYSTEM) DOWN.6" STORM (PRIMARY SYSTEM) UP.6" STORM (PRIMARY SYSTEM) DOWN.214" SANITARY/WASTE STACK UP AND DOWN.224" SANITARY UP WITHIN CHASE ON SECOND FLOOR.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABCE3.8F3.9PUBLICTOILET200APUBLICTOILET200BSTAFFTOILET205EXAM210EXAM211EXAM212EXAM215EXAM216EXAM217EXAM(GYN)218SHAREDCLEANWORK/MEDPREP219EXAM(GYN)PoS220PATIENTTOILET222VISITORTOILET(PoS)224DENTALTREATMENTROOM225DENTALEQUIPMENTSTERILIZATION227SHAREDSOILEDHOLDING229SHAREDEQUIPMENTSTORAGE231EVS226VITALSALCOVE223STAIRST2-2CORRIDOR232RESPITE/LACTATION240STAFFTOILET237STAIR2ST2-1MAINLOBBY100RESPITE/MEDITATION241OFFICE238UnoccupiedUnoccupiedCIRCULATION228DENTALOFFICE230WAITING201SHAREDMULTIPURPOSE/CONSULT/TELEMED206SHAREDRECEPTION/REGISTRATION202SHAREDCLERICALOFFICE203CIRCULATION207NURSE214PHYSICIANOFFICE/DICTATION213LAB221MANAGEROFFICE209SHAREDSTAFFBREAK208MULTIPURPOSE/CONSULT/TELEMED204EDUCATION/CONFERENCE234IT/ELEC2431121W3MULTIPURPOSE/ACTIVITY235RESPITE/LACTATION239STAFFTOILET236TELMED233WWW1 1/2"4"1 1/2"4"2"WW654666451 1/2"6661 1/2"1 1/2"2"66W2"2"W66W64"4"666544"4"5461 1/2"4"1 1/2"666W1 1/2"2"WW662"6645654W1 1/2"4"4"4"4566547131313STAFFBREAK242STAFFBREAK242CIRCULATION207CIRCULATION228WALKINGTRACK200ELEVA200EAELEVB200EBSTAIR1ST1-24"1415ST13STST4"4"1514STST1686"6"1110664559121 1/2"4"1 1/2"STST6"6"10111681 1/2"62"1 1/2"1 1/2"6WW66661 1/2"6W2"2"1 1/2"1 1/2"4"4"4"3"1 1/2"2"1 1/2"2"4"2"4"4"4"4"1 1/2"1 1/2"64"17803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:06:20 PMP102SECONDFLOOR PLAN -SANITARY/WASTE ANDSTORM02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1SECOND FLOOR PLAN - SANITARY/WASTE AND STORMDRAWING NOTES:1114" SANITARY/WASTE STACK UP AND DOWN.24" SANITARY/WASTE UP.34" SANITARY/WASTE DOWN.GENERAL NOTES:1. PROVIDE WALL PLATE CLEANOUTS OR CLEANOUT TEES AT THE BASE OF ALL SANITARY/WASTE AND STORM STACKS.2. COORDINATE SANITARY/WASTE OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.44" SANITARY UP TO WATER CLOSET.52" VENT UP.61 1/2" WASTE UP TO SINK/LAVATORY. 71 1/2" WASTE UP TO ELECTRIC WATER COOLER. 893" WASTE (WITH TRAP) UP TO MOP SERVICE SINK.10121 1/2" WASTE UP TO BACK-TO-BACK SINK/LAVATORY. CONNECT 1 1/2" WASTE TO EACH SINK/LAVATORY.134" STORM UP TO ROOF DRAIN (RD-A).144" STORM (PRIMARY SYSTEM) DOWN.154" STORM (SECONDARY SYSTEM) DOWN.166" STORM (PRIMARY SYSTEM) DOWN.6" STORM (SECONDARY SYSTEM) DOWN.6" STORM (PRIMARY SYSTEM) UP.6" STORM (SECONDARY SYSTEM) UP.17CONNECT 4" SANITARY/WASTE TO WALL MOUNTED WATER CLOSET. RUN 4" SANITARY/WASTE IN CHASE WALL (TO AVOID BEAM BELOW)AND DOWN TO FIRST FLOOR CEILING.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8ELEC/DATA323STAIR2ST2-1STAIR1ST1-3W3211STAFFBREAKAREA305STAFFTOILET305ASPECIMENCOLLECTION333876746W4"1 1/2"4"1 1/2"4"4"4"96765491 1/2"4"41 1/2"10741 1/2"1 1/2"92"41 1/2"4"44WW4467WW4"4"4"1 1/2"4"467674446741 1/2"W413111412EXAM/CONSULT327TRIAGENURSE339BPATIENTTOILET336SPECIALTYEXAM/TREATMENT/TELEMED335PATIENTTOILET335ALAB334LABDRAW332GUESTWAITING/CIRCULATION300PUBLICTOILET300BPUBLICTOILET300AREGISTRATION301CENTRALSOILEDWORK311PATIENTVITALSALCOVE310EXAM/CONSULT309SPECIALTYEXAM/TREATMENT303OFFICEMANAGER301APATIENTTOILET302EXAM/CONSULT307EXAM/CONSULT306EXAM/CONSULT308NURSEWORKAREA317BPROVIDEROFFICE317AEXAM/CONSULT316EXAM/CONSULT315EXAM/CONSULT314EXAM/CONSULT313CIRCULATION304EXAM/CONSULT318EXAM/CONSULT319EXAM/CONSULT320EXAM/CONSULT321EXAM/CONSULT322CENTRALCLEANWORK312EXAM/CONSULT328EXAM/CONSULT331EXAM/CONSULT328PROVIDEROFFICE339AEXAM/CONSULT329EVS330NURSEWORK339PATIENTTOILET327SPECIALTYEXAM/TREATMENT326PATIENTTOILET326ATRIAGENURSE324PROVIDEROFFICE317FNURSEWORKAREA317BCIRCULATION304CIRCULATION304STST6"6"14131211W4"1 1/2"4"4764"W476104"4"4"441 1/2"2"2"44152"NURSEWORKAREA317ECIRCULATION3044"4"WW2"4"41 1/2"4"3"21 1/2"1 1/2"4"2"1 1/2"W2"631 1/2"STAFFTOILET325803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:06:33 PMP103THIRD FLOORPLAN -SANITARY/WASTE ANDSTORM02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1THIRD FLOOR PLAN - SANITARY/WASTE AND STORMDRAWING NOTES:4GENERAL NOTES:1. PROVIDE WALL PLATE CLEANOUTS OR CLEANOUT TEES AT THE BASE OF ALL SANITARY/WASTE AND STORM STACKS.2. COORDINATE SANITARY/WASTE OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.1 1/2" WASTE UP TO SINK/LAVATORY. 1 1/2" WASTE UP TO ELECTRIC WATER COOLER. 564" SANITARY UP TO WATER CLOSET.72" VENT UP.14" SANITARY/WASTE STACK UP AND DOWN.24" SANITARY/WASTE UP.34" SANITARY/WASTE DOWN.81 1/2" WASTE UP TO BACK-TO-BACK LAVATORY/BOTTLE FILLER. CONNECT 1 1/2" WASTE TO LAVATORY AND BOTTLE FILLER.91 1/2" WASTE UP TO BACK-TO-BACK SINKS/LAVATORIES. CONNECT 1 1/2" WASTE TO EACH SINK/LAVATORY.103" WASTE (WITH TRAP) UP TO MOP SERVICE SINK.116" STORM (PRIMARY SYSTEM) DOWN.126" STORM (SECONDARY SYSTEM) DOWN.136" STORM (PRIMARY SYSTEM) UP.146" STORM (SECONDARY SYSTEM) UP.152" WASTE UP TO DISINFECTION UNIT.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8PATIENTTOILET444SHAREDCONFERENCE433PATIENTTOILET418BELEC/DATA430NURSE/TECHSTATION411PATIENTTOILET413MAMMOGRAPHY427STAFFTOILET414EQUIPMENTSTORAGE431APATIENTTOILET424APATIENTTOILET(PoS)423APATIENTTOILET415AHOLDINGBAY1412ACIRCULATION406PATIENTTOILET407BPUBLICTOILET400BPUBLICTOILET400ASTAFFTOILET445EVS439STAIR1ST1-3STAIR2ST2-1PROCEDUREROOM442STAFFBREAK443PROCEDUREROOM441CIRCULATION435SOILEDWORKROOM438PROCEDUREROOM440RECEPTION436WAITING434PROVIDEROFFICE436ACLEANWORKROOM&EQUIP.STORAGE437ELEVATORLOBBY&PUBLICCORRIDOR400IMAGINGGUESTLOUNGE/WAITING401WHEELCHAIRSTORAGE400CREGISTRATION402WOMEN'SCIRCULATION407GOWNING2407CGOWNING3407DSTAIR3ST3-4GOWNING1407AWOMEN'SCIRCULATION425ULTRASOUND(GUIDEDBIOPSY)415ULTRASOUND424ULTRASOUND(PoS)423DIAGNOSTICRADIOGRAPHY416SOILEDWORKROOM420CLEANWORKROOM419MEN'SCIRCULATION422DEXASCAN432MAMMOGRAPHY(STEREOTATICBIOPSY)431READINGROOM426EQUIPMENTSTORAGE&FLEXSPACE421GOWNING418ACIRCULATION412HOLDINGBAY2412BMEN'SSUB-WAIT418MULTIPURPOSE/CONSULT405PRACTICEMANAGER403OFFICE/READING428IMAGINGIT/DATA429EVS41723W1311 1/2"4"4"1 1/2"4"2"1 1/2"1 1/2"4"681154664"66452"661 1/2"4"WWWWW6544144"6W54"61 1/2"6WW66666WW6W1 1/2"4"4"5466WW4"4569544"4"7W1 1/2"4"45W1 1/2"2"6451 1/2"1312105STST131210116"6"ELEVATORLOBBY&PUBLICCORRIDOR400661 1/2"4"662"2"1 1/2"1 1/2"4"664"4"62"4"6W6661 1/2"64"62"2"4"4"4"WOMEN'SCIRCULATION4251 1/2"1 1/2"1 1/2"1 1/2"1 1/2"21 1/2"2"1 1/2"1 1/2"2"1 1/2"W4"4"61 1/2"WOMEN'SSUB-WAIT409RESULTSALCOVE410803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:06:46 PMP104FOURTHFLOOR PLAN -SANITARY/WASTE ANDSTORM02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1FOURTH FLOOR PLAN - SANITARY/WASTE AND STORMDRAWING NOTES:GENERAL NOTES:1. PROVIDE WALL PLATE CLEANOUTS OR CLEANOUT TEES AT THE BASE OF ALL SANITARY/WASTE AND STORM STACKS.2. COORDINATE SANITARY/WASTE OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.44" SANITARY UP TO WATER CLOSET.52" VENT UP.61 1/2" WASTE UP TO SINK/LAVATORY. 71 1/2" WASTE UP TO ELECTRIC WATER COOLER. 83" WASTE (WITH TRAP) UP TO MOP SERVICE SINK.14" VENT UP, 4" SANITARY/WASTE DOWN.24" VENT UP.34" SANITARY/WASTE DOWN.91 1/2" WASTE UP TO BACK-TO-BACK LAVATORY/BOTTLE FILLER. CONNECT 1 1/2" WASTE TO LAVATORY AND BOTTLE FILLER.106" STORM (PRIMARY SYSTEM) DOWN.116" STORM (SECONDARY SYSTEM) DOWN.126" STORM (PRIMARY SYSTEM) UP.136" STORM (SECONDARY SYSTEM) UP.141 1/2" WASTE UP TO BACK-TO-BACK SINKS/LAVATORIES. CONNECT 1 1/2" WASTE TO EACH SINK/LAVATORY.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8EXAM/CONSULT521EXAM/CONSULT507PROVIDEROFFICE539ANURSEWORK539EXAM/CONSULT528EXAM/CONSULT529PATIENTTOILET527CIRCULATION504SPECIALTYEXAM/TREATMENT526PATIENTTOILET526ASTAFFTOILET525TRIAGENURSE524IT/ELEC523PROVIDEROFFICE517FNURSEWORKAREA517EEXAM/CONSULT518EXAM/CONSULT519EXAM/CONSULT520EXAM/CONSULT522EXAM/CONSULT513CIRCULATION504BBEXAM/CONSULT514EXAM/CONSULT515EXAM/CONSULT516STAFFCIRCULATION517PROVIDEROFFICE517ANURSEWORKAREA517BEXAM/CONSULT509EXAM/CONSULT508SPECIALTYEXAM/TREATMENT506STAIRVESTIBULE504ASTAFFBREAKAREA505OFFICEMANAGER502APATIENTTOILET503REGISTRATION502PUBLICTOILET501APUBLICTOILET501BSPECIMENCOLLECTION533LABDRAW532LAB534PATIENTTOILET535ASPECIALTYEXAM/TREATMENT/TELEMED535ELEVATORCONTROLROOM500EXAM/CONSULT537PATIENTTOILET536TRIAGENURSE539BEXAM/CONSULT531REGISTRATION502STAIR1ST1-3PATIENTVITALSALCOVE510STAIRST2-2STAFFTOILET505AUnoccupiedUnoccupiedSTAFFCIRCULATION517CENTRALSOILEDWORK511EXAM/CONSULT5381111ST6"6"32236"6"GUESTWAITING/CIRCULATION501ELEVB500EBELEVA500EACIRCULATION504803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:06:57 PMP105FIFTH FLOORPLAN -SANITARY/WASTE ANDSTORM02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNDRAWING NOTES:1GENERAL NOTES:1. PROVIDE WALL PLATE CLEANOUTS OR CLEANOUT TEES AT THE BASE OF ALL SANITARY/WASTE AND STORM STACKS.2. COORDINATE SANITARY/WASTE OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.3/16" = 1'-0"1FIFTH FLOOR PLAN - SANITARY/WASTE AND STORM236" STORM UP TO ROOF DRAIN (RD-A).6" STORM (SECONDARY SYSTEM) DOWN.6" STORM (PRIMARY SYSTEM) DOWN.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 1235ABCEF3.94" RD-A4" RD-A6" RD-A6" RD-A4" VTR4" VTR4" VTR4" VTR123803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:07:14 PMP106ROOF PLAN02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1ROOF PLANDRAWING NOTES:1PROVIDE NON-FREEZE ROOF HYDRANT WITH GALVANIZED CASING AND ADJUSTABLE FLOW WHEEL LOCK HANDLE WITH DECK FLANGE AND UNDER DECK CLAMP EQUAL TO JAY R SMITH MODEL 5906-H. PROVIDE VACUUM BREAKER. 1/8”DRAIN HOLE MUST BE PIPED AND DISCHARGED TO AN ACCEPTABLE DISCHARGE POINT. REFER TO DETAIL DRAWING(S).2CONNECT 3/4" INDIRECT WASTE TO HEAT PUMP (BY MECHANICAL CONTRACTOR). REFER TO DETAIL DRAWING(S).3TERMINATE 3/4" INDIRECT WASTE 6" ABOVE FINISHED ROOF. SLEEVE AND SEAL THROUGH EXTERIOR WALL.1. COORDINATE ALL VENT THROUGH ROOF (VTR) WITH HVACCONTRACTOR. ALL VENT TERMINATIONS ABOVE ROOF SHALL BE A MINIMUM 25'-0" (HEALTHCARE) AWAY FROM ANY HVAC OUTSIDE AIR INTAKE (ROOFTOP UNIT, LOUVER, ETC). OR AT LEAST 3 FEET ABOVE WINDOW, DOOR, OPENING, AIR INTAKE OR VENT SHAFT.GENERAL NOTES:REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 REF.12345ABCE3.8F3.9WASTEHOLDING136STAFFBREAK133SOILED132CLEANSUPPLY134REGISTRATION124PUBLICTOILET100AEXAM121EXAM120SOILEDWORK111EXAM112EXAM115EXAM114PoSPATIENTTOILET105CCLEANLINENHOLDING137TRIAGE/INTERVIEW106STAFFTOILET103EXAM116STORAGE144WATERSERVICE146SUPPLYCHAINAREA138EVSSUPPLY&EQUIPMENT139EXAM118MAINELECTRICAL142EMERGENCYEQUIPMENTROOM141MAINSERVER140VESTIBULE100V2VESTIBULE100V1HOLDING/MAIL100CCIRCULATION105CIRCULATION105VITALSALCOVE105ASUB-WAITING105BSTAIR2ST2-1CIRCULATION105CORRIDOR122134WH5WH5WH5SPECIMENTOILET127BLOODDRAW130BLOODDRAW129BLOODDRAW(PoS)128WAITING/CIRCULATION123CORRIDOR135LABORATORY126STAFFTOILET131MAINLOBBY100EVS125RADIOLOGY(X-RAY)119CORRIDOR143TREATMENT117EXAM113STATLAB/MED110CLEANHOLDING107SHAREDPROVIDEROFFICE104STAFFBREAK102BUILDINGMAINTENANCETOILET/SHOWER138A4"3"HHWRVCC1"HHWRVC1 1/2"1"3/4"2"3/4"1 1/2"1 1/2"3/4"HHWRC2"3/4"HHWRCHHWRCV255127777PUBLICTOILET100BMECHANICAL145CORRIDOR143WAITING/CIRCULATION123134"4"2"WH3"VVHHWRCVHHWRCVVC3/4"2"14151416668173/4"6817661796661110178661789817661166817116666817966MSS-ALAV-AWC-ALAV-AWC-ALAV-AWC-ALAV-AWC-ABF-ASINK-BSINK-ASINK-ASINK-ABF-ASINK-ALAV-AEWC-ALAV-AWC-ASINK-ASINK-ASINK-ASINK-AMSS-ASINK-ABF-ASINK-ASINK-A6SINK-A6SINK-A6SINK-ASINK-A6SINK-ALAV-AWC-AMSS-ASINK-A11BF-A17CV6SINK-A6LAV-AWC-A3/4"C C3/4"3/4"2"V3"2"2"2"3/4"3/4"2"3/4"4"3/4"2"3/4"4"2"2"1 1/2"3/4"2"1"2"3/4"3"1 1/2"2"3/4"3/4"3/4"2"2"1"3/4"2"3/4"1 1/2"1/2"1/2"6817LAV-AWC-A61818181817V 2"1719SHR-B2"1 1/2"20183/4"3/4"3/4"2"LOBBY/WAITING101RECEPTION101BLOBBY/WAITING101WAITING/CIRCULATION123803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:08:04 PMP201FIRST FLOORPLAN -DOMESTIC02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNDRAWING NOTES:1DUPLEX BOOSTER PUMP (DBP-1). REFER TO DETAIL DRAWING(S).4" REDUCED PRESSURE ZONE (RPZ) MAKE: WATTS LF957. PROVIDE 6" DRAIN. PROVIDE FUNNEL FITTING CENTERED UNDER RPZ RELIEF VALVE. RPZ RELIEF GAP SHALL BE A MINIMUM OF TWO TIMES THE RPZ DISCHARGE OPENING. REFER TO DETAIL DRAWING(S).2346" COMBINED WATER SERVICE DOWN.5SLEEVE AND SEAL.3/16" = 1'-0"1FIRST FLOOR PLAN - DOMESTIC6DROP 1/2" HOT AND COLD AND 1 1/2" VENT TO SINK/LAVATORY. 1 1/2" WASTE DOWN.74" VENT UP.8DROP 1 1/2" COLD TO WATER CLOSET.9DROP 3/4" HOT AND COLD TO MOP SERVICE SINK. PROVIDE CHECK VALVES IN SUPPLY LINES.10DROP 1/2" COLD AND 1 1/2" VENT TO ELECTRIC WATER COOLER. 1 1/2" WASTE DOWN.11DROP 1/2" COLD AND 1 1/2" VENT TO BOTTLE FILLER. 1 1/2" WASTE DOWN.GENERAL NOTES:1. PROVIDE SHUT-OFF VALVES ON ALL COLD AND HOT BRANCH LINES, NOT ALL VALVES CAN BE SHOWN DUE TO SCALE OF DRAWINGS.2. PROVIDE A PRESSURE REDUCING VALVE (PRV) ON DOMESTIC RISERS WHEN PRESSURES EXCEED 65 PSI.3. COORDINATE DOMESTIC OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.2WATER SERVICE ROOM 3D VIEW2" REDUCED PRESSURE ZONE (RPZ) MAKE: WATTS LF909, PROVIDE 4" DRAIN. PROVIDE FUNNEL FITTING CENTERED UNDER RPZ RELIEF VALVE. RPZ RELIEF GAP SHALL BE A MINIMUM OF TWO TIMES THE RPZ DISCHARGE OPENING. REFER TO DETAIL DRAWING(S).12DOMESTIC BLADDER TANK (DBT-1). REFER TO DETAIL DRAWING(S).134" COLD UP.14PROVIDE DECK MOUNTED EYEWASH (EW-A) AT SINK AS SPECIFIED. REFER TO DETAIL DRAWING(S).15PROVIDE WALL MOUNTED EYEWASH (EW-B) AT MOP SINK AS SPECIFIED. REFER TO DETAIL DRAWING(S).16DOMESTIC WATER HEATER (HWH-1). COORDINATE WITH MECHANICAL CONTRACTOR (INLET/OUTLET DUCT CONNECTIONS) PRIOR TO START OF WORK. REFER TO DETAIL DRAWING(S).172" VENT DOWN.18PROVIDE BALANCING VALVE ARRANGEMENT. REFER TO DETAIL DRAWING(S).19DROP 1/2" HOT AND COLD TO SHOWER.20DROP 1/2" HOT & 1 1/2" COLD AND PROVIDE SHUT-OFF VALVES IN ACCESS PANEL (BY PLUMBING CONTRACTOR). ACCESS PANEL SHALL BE LOCATED IN WALL 48" ABOVE THE FINSHED FLOOR AND OPEN TO THE CORRIDOR.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABCE3.8F3.9PUBLICTOILET200APUBLICTOILET200BSTAFFTOILET205EXAM210EXAM211EXAM212EXAM215EXAM216EXAM217EXAM(GYN)218SHAREDCLEANWORK/MEDPREP219EXAM(GYN)PoS220PATIENTTOILET222VISITORTOILET(PoS)224DENTALTREATMENTROOM225DENTALEQUIPMENTSTERILIZATION227SHAREDSOILEDHOLDING229SHAREDEQUIPMENTSTORAGE231EVS226VITALSALCOVE223CORRIDOR232RESPITE/LACTATION240STAFFTOILET237STAIR2ST2-1MAINLOBBY100RESPITE/MEDITATION241OFFICE238UnoccupiedUnoccupiedCIRCULATION228DENTALOFFICE230WAITING201SHAREDMULTIPURPOSE/CONSULT/TELEMED206SHAREDRECEPTION/REGISTRATION202SHAREDCLERICALOFFICE203CIRCULATION207NURSE214PHYSICIANOFFICE/DICTATION213LAB221MANAGEROFFICE209SHAREDSTAFFBREAK208MULTIPURPOSE/CONSULT/TELEMED204EDUCATION/CONFERENCE234IT/ELEC24388872VMULTIPURPOSE/ACTIVITY235STAFFBREAK242RESPITE/LACTATION239STAFFTOILET236TELMED2339HHWRCHHWRCCHHWRH H W RC HHWRCVV10111LAV-B12WC-A12SHR-A131LAV-B1LAV-B12SHR-A1316WC-B1LAV-B1SINK-C1SINK-A1LAV-A1SINK-D1LAV-A12MSS-A1SINK-A1SINK-A1SINK-A1SINK-A1SINK-A1SINK-A1SINK-B6BF-A1SINK-AWC-A1LAV-B12125EWC-A3112WC-ALAV-A6BF-A1LAV-A3WC-A121231WC-ALAV-A4CHHWRVCH1SINK-A1SINK-A1SINK-A1SINK-AHHWRC1LAV-A32"1 1/2"HHWRCV3"HHWRCV3/4"2"1"1"1/2"1/2"2"1 1/2"33/4"3/4"3/4"1 1/2"VV2"1"3/4"3/4"1"2 1/2"1"1"3/4"2"1 1/2"3/4"3"2"2"2"1 1/2"3/4"3/4"2"3/4"1 1/2"2"2"1 1/2"3/4"2"2"3/4"3/4"3/4"2"2"3/4"3/4"1 1/2"1 1/2"3/4"3/4"1"3/4"2"2"2"3/4"3/4"2"14141414141415803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:08:19 PMP202SECONDFLOOR PLANS -DOMESTIC02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1SECOND FLOOR PLAN - DOMESTICDRAWING NOTES:1DROP 1/2" HOT AND COLD AND 1 1/2" VENT TO SINK/LAVATORY. 1 1/2" WASTE DOWN.24" VENT UP.3DROP 1 1/2" COLD TO WATER CLOSET.4DROP 3/4" HOT AND COLD TO MOP SERVICE SINK. PROVIDE CHECK VALVES IN SUPPLY LINES.5DROP 1/2" COLD AND 1 1/2" VENT TO ELECTRIC WATER COOLER. 1 1/2" WASTE DOWN.6DROP 1/2" COLD AND 1 1/2" VENT TO BOTTLE FILLER. 1 1/2" WASTE DOWN.GENERAL NOTES:1. PROVIDE SHUT-OFF VALVES ON ALL COLD AND HOT BRANCH LINES, NOT ALL VALVES CAN BE SHOWN DUE TO SCALE OF DRAWINGS.2. PROVIDE A PRESSURE REDUCING VALVE (PRV) ON DOMESTIC RISERS WHEN PRESSURES EXCEED 65 PSI.3. COORDINATE DOMESTIC OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.74" VENT DOWN.84" VENT STACK UP AND DOWN.94" COLD RISER UP AND DOWN.10PROVIDE DECK MOUNTED EYEWASH (EW-A) AT SINK AS SPECIFIED. REFER TO DETAIL DRAWING(S).11DOMESTIC WATER HEATER (HWH-1). COORDINATE WITH MECHANICAL CONTRACTOR (INLET/OUTLET DUCT CONNECTIONS) PRIOR TO START OF WORK. REFER TO DETAIL DRAWING(S).122" VENT DOWN.13DROP 1/2" HOT AND COLD TO SHOWER.14PROVIDE BALANCING VALVE ARRANGEMENT. REFER TO DETAIL DRAWING(S).15STANDARD WATER CLOSET WITH BARIATRIC SPACING (SEE ARCHITECTURAL DRAWINGS) AND BARIATRIC GRAB BAR SUPPORTS (BY GENERAL CONTRACTOR). BARIATRIC LAVATORY SUPPORTS, COORDINATE WITH GENERAL CONTRACTOR.16DROP 1 1/2" COLD AND 2" VENT TO WATER CLOSET.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8ELEC/DATA323NURSEWORKAREA317BSTAIR2ST2-1STAIR1ST1-388827PROVIDEROFFICE339ANURSEWORK339EXAM/CONSULT328EXAM/CONSULT329PATIENTTOILET327SPECIALTYEXAM/TREATMENT326STAFFTOILET325PATIENTTOILET326ATRIAGENURSE324PROVIDEROFFICE317FEXAM/CONSULT322EXAM/CONSULT321EXAM/CONSULT320EXAM/CONSULT319EXAM/CONSULT318EXAM/CONSULT316EXAM/CONSULT315EXAM/CONSULT314EXAM/CONSULT313CENTRALCLEANWORK312CIRCULATION304EXAM/CONSULT331EXAM/CONSULT328EXAM/CONSULT327TRIAGENURSE339BPATIENTTOILET336SPECIALTYEXAM/TREATMENT/TELEMED335PATIENTTOILET335ALAB334SPECIMENCOLLECTION333LABDRAW332CENTRALSOILEDWORK311PROVIDEROFFICE317AEXAM/CONSULT306EXAM/CONSULT307EXAM/CONSULT308EXAM/CONSULT309PATIENTVITALSALCOVE310CIRCULATION304PUBLICTOILET300BPUBLICTOILET300AGUESTWAITING/CIRCULATION300REGISTRATION301OFFICEMANAGER301APATIENTTOILET302SPECIALTYEXAM/TREATMENT303STAFFBREAKAREA305STAFFTOILET305A910111SINK-A1SINK-AMSS-A1SINK-A3WC-A1LAV-A121SINK-A1LAV-A123WC-A3WC-A1LAV-A1SINK-A1SINK-A121LAV-A11WC-A3SINK-A1LAV-A33WC-AWC-ALAV-A1SINK-A1SINK-A1SINK-DSINK-A3WC-A1LAV-A1SINK-C1SINK-A31WC-ALAV-A121212123WC-A121LAV-A123WC-A5EWC-A4VHWRCHHWRCHHWRCHHWRC1SINK-A1SINK-A1SINK-A1SINK-AHHWRCV1SINK-A1SINK-A1SINK-A111SINK-AHHWRCVV1SINK-AHHWRCVHHHWRCHHWRC1SINK-A1SINK-A1SINK-AV1SINK-A1SINK-A1SINK-A1VHHWRCVV1LAV-A101 1/2"3/4"1"2"3/4"2"1/2"1/2"3"1 1/2"2"3/4"1"2"1"3/4"3/4"2"2"2"3/4"3/4"2"1 1/2"2"3/4"1/2"1 1/2"2"2"3/4"2"2"2"4"VVHWRCH131313131313131313132"3/4"3/4"3/4"1"1"3/4"1"1"3/4"2"1 1/2"3/4"3/4"3"2"2"3/4"2"2 1/2"3/4"2"2 1/2"2"2"3/4"1"1"3/4"2"1 1/2"1 1/2"1"3/4"2"3/4"1 1/2"2"2"3/4"1"1"2"1/2"1/2"3/4"3/4"1 1/2"2"2"2"1 1/2"3/4"3/4"2 1/2"1SINK-A142"133/4"2"803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:08:35 PMP203THIRD FLOORPLAN -DOMESTIC02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1THIRD FLOOR PLAN - DOMESTICGENERAL NOTES:1. PROVIDE SHUT-OFF VALVES ON ALL COLD AND HOT BRANCH LINES, NOT ALL VALVES CAN BE SHOWN DUE TO SCALE OF DRAWINGS.2. PROVIDE A PRESSURE REDUCING VALVE (PRV) ON DOMESTIC RISERS WHEN PRESSURES EXCEED 65 PSI.3. COORDINATE DOMESTIC OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.DRAWING NOTES:1DROP 1/2" HOT AND COLD AND 1 1/2" VENT TO SINK/LAVATORY. 1 1/2" WASTE DOWN.24" VENT UP.3DROP 1 1/2" COLD TO WATER CLOSET.4DROP 3/4" HOT AND COLD TO MOP SERVICE SINK. PROVIDE CHECK VALVES IN SUPPLY LINES.5DROP 1/2" COLD AND 1 1/2" VENT TO ELECTRIC WATER COOLER. 1 1/2" WASTE DOWN.6DROP 1/2" COLD AND 1 1/2" VENT TO BOTTLE FILLER. 1 1/2" WASTE DOWN.74" VENT DOWN.84" VENT STACK UP AND DOWN.94" COLD RISER UP AND DOWN.10PROVIDE DECK MOUNTED EYEWASH (EW-A) AT SINK AS SPECIFIED. REFER TO DETAIL DRAWING(S).11DOMESTIC WATER HEATER (HWH-1). COORDINATE WITH MECHANICAL CONTRACTOR (INLET/OUTLET DUCT CONNECTIONS) PRIOR TO START OF WORK. REFER TO DETAIL DRAWING(S).122" VENT DOWN.13PROVIDE BALANCING VALVE ARRANGEMENT. REFER TO DETAIL DRAWING(S).14DROP 1/2" HOT & 1 1/2" COLD AND PROVIDE SHUT-OFF VALVES IN ACCESS PANEL (BY PLUMBING CONTRACTOR). ACCESS PANEL SHALL BE LOCATED IN WALL 48" ABOVE THE FINSHED FLOOR AND OPEN TO THE CORRIDOR.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8PATIENTTOILET444SHAREDCONFERENCE433PATIENTTOILET418BELEC/DATA430NURSE/TECHSTATION411PATIENTTOILET413MAMMOGRAPHY427STAFFTOILET414EQUIPMENTSTORAGE431APATIENTTOILET424APATIENTTOILET(PoS)423APATIENTTOILET415AHOLDINGBAY1412ACIRCULATION406PATIENTTOILET407BPUBLICTOILET400BPUBLICTOILET400ASTAFFTOILET445EVS439STAIR2ST2-1MAINLOBBY100PROCEDUREROOM442STAFFBREAK443PROCEDUREROOM441CIRCULATION435SOILEDWORKROOM438PROCEDUREROOM440RECEPTION436WAITING434PROVIDEROFFICE436ACLEANWORKROOM&EQUIP.STORAGE437ELEVATORLOBBY&PUBLICCORRIDOR400IMAGINGGUESTLOUNGE/WAITING401WHEELCHAIRSTORAGE400CREGISTRATION402WOMEN'SCIRCULATION407GOWNING2407CGOWNING3407DSTAIR3ST3-4GOWNING1407AWOMEN'SCIRCULATION425ULTRASOUND(GUIDEDBIOPSY)415ULTRASOUND424ULTRASOUND(PoS)423DIAGNOSTICRADIOGRAPHY416SOILEDWORKROOM420CLEANWORKROOM419MEN'SCIRCULATION422DEXASCAN432MAMMOGRAPHY(STEREOTATICBIOPSY)431READINGROOM426EQUIPMENTSTORAGE&FLEXSPACE421GOWNING418AHOLDINGBAY2412BMEN'SSUB-WAIT418MULTIPURPOSE/CONSULT405PRACTICEMANAGER403OFFICE/READING428IMAGINGIT/DATA429EVS4172888V4"79101011121SINK-A1SINK-AWC-ALAV-A311SINK-A1SINK-A4MSS-A131SINK-A1SINK-A1SINK-A1SINK-A1LAV-A3WC-A4MSS-A133WC-A131LAV-A133WC-A6BF-A1LAV-A5EWC-A13WC-A31LAV-A133WC-A1LAV-A1SINK-A1311SINK-ALAV-A3WC-A1SINK-A133WC-A1SINK-A1SINK-A1SINK-A1SINK-A1LAV-A3WC-A3WC-A1LAV-A13HHWRCHHWRCHHWRCHHWRC1SINK-A1SINK-AVHWRCH134"1SINK-AV1SINK-AVVHHWRCHHWRCVHCVVV1LAV-AHHWRCHHWRCVHWRCHHHWRCVV3/4"3/4"3/4"3/4"4"2"LAV-A12"1/2"1/2"V2"1 1/2"3/4"2"2"1/2"1/2"2"2"2"2"2"2"2"1 1/2"1 1/2"3/4"3/4"2"3/4"1 1/2"1/2"2"1 1/2"3/4"2"2"2"1 1/2"3/4"3/4"3/4"1 1/2"3/4"3/4"1/2"1/2"1 1/2"2"VV2"2"HWR1414141414141414142"2"1"1"3/4"1 1/2"3/4"2"3/4"1/2"1/2"2"1"3/4"2"1"1"3/4"2"1 1/2"3/4"1/2"1/2"3/4"1 1/2"2"2"1 1/2"3/4"2"3/4"2 1/2"2 1/2"3/4"2"2"2 1/2"1 1/2"3/4"1 1/2"2"1/2"3/4"1 1/2"1"3/4"1414WOMEN'SSUB-WAIT409RESULTSALCOVE410803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:08:52 PMP204FOURTHFLOOR PLAN -DOMESTIC02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1FOURTH FLOOR PLAN - DOMESTICGENERAL NOTES:1. PROVIDE SHUT-OFF VALVES ON ALL COLD AND HOT BRANCH LINES, NOT ALL VALVES CAN BE SHOWN DUE TO SCALE OF DRAWINGS.2. PROVIDE A PRESSURE REDUCING VALVE (PRV) ON DOMESTIC RISERS WHEN PRESSURES EXCEED 65 PSI.3. COORDINATE DOMESTIC OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.DRAWING NOTES:1DROP 1/2" HOT AND COLD AND 1 1/2" VENT TO SINK/LAVATORY. 1 1/2" WASTE DOWN.24" VENT UP.3DROP 1 1/2" COLD TO WATER CLOSET.4DROP 3/4" HOT AND COLD TO MOP SERVICE SINK. PROVIDE CHECK VALVES IN SUPPLY LINES.5DROP 1/2" COLD AND 1 1/2" VENT TO ELECTRIC WATER COOLER. 1 1/2" WASTE DOWN.6DROP 1/2" COLD AND 1 1/2" VENT TO BOTTLE FILLER. 1 1/2" WASTE DOWN.74" VENT DOWN.84" VENT STACK UP AND DOWN.94" COLD RISER UP AND DOWN.10PROVIDE DECK MOUNTED EYEWASH (EW-A) AT SINK AS SPECIFIED. REFER TO DETAIL DRAWING(S).11DROP 1/2" HOT AND COLD AND 1 1/2" VENT TO DISINFECTION UNIT (BY OTHER). 2" WASTE DOWN.12DOMESTIC WATER HEATER (HWH-1). COORDINATE WITH MECHANICAL CONTRACTOR (INLET/OUTLET DUCT CONNECTIONS) PRIOR TO START OF WORK. REFER TO DETAIL DRAWING(S).132" VENT DOWN.14PROVIDE BALANCING VALVE ARRANGEMENT. REFER TO DETAIL DRAWING(S).REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8EXAM/CONSULT521EXAM/CONSULT507PROVIDEROFFICE539ANURSEWORK539EXAM/CONSULT528EXAM/CONSULT529PATIENTTOILET527SPECIALTYEXAM/TREATMENT526PATIENTTOILET526ASTAFFTOILET525TRIAGENURSE524IT/ELEC523PROVIDEROFFICE517FNURSEWORKAREA517EEXAM/CONSULT518EXAM/CONSULT519EXAM/CONSULT520EXAM/CONSULT522EXAM/CONSULT513CIRCULATION504BBEXAM/CONSULT514EXAM/CONSULT515EXAM/CONSULT516STAFFCIRCULATION517PROVIDEROFFICE517ANURSEWORKAREA517BEXAM/CONSULT509EXAM/CONSULT508SPECIALTYEXAM/TREATMENT506STAIRVESTIBULE504ASTAFFBREAKAREA505OFFICEMANAGER502APATIENTTOILET503REGISTRATION502PUBLICTOILET501APUBLICTOILET501BSPECIMENCOLLECTION533LABDRAW532LAB534PATIENTTOILET535ASPECIALTYEXAM/TREATMENT/TELEMED535ELEVATORCONTROLROOM500EXAM/CONSULT537PATIENTTOILET536TRIAGENURSE539BEXAM/CONSULT531REGISTRATION502STAIR1ST1-3PATIENTVITALSALCOVE510CIRCULATION504STAIRST2-2STAFFTOILET505ASTAFFCIRCULATION517REGISTRATION502CENTRALSOILEDWORK511EXAM/CONSULT53812V4"277212GUESTWAITING/CIRCULATION5018910911SINK-A1SINK-AMSS-A1SINK-A3WC-A1LAV-A1SINK-A1LAV-A113WC-A3WC-A1LAV-A1SINK-ASINK-A111LAV-A11WC-A31SINK-ALAV-AWC-AWC-A1SINK-A1SINK-D1SINK-A3WC-A1LAV-A1SINK-CWC-ALAV-A31111113WC-A1LAV-A111LAV-A3WC-A5EWC-A411HHWRCHHWRCHHWRCHHWRC1331SINK-A1SINK-A1SINK-A11V1SINK-A1SINK-AVVHHWRC1SINK-A1SINK-ALAV-AHHWRCHHWRCV1SINK-A1SINK-A1SINK-A1SINK-A1SINK-AHHWRCV1SINK-A3/4"2"3/4"11111SINK-A1SINK-A1SINK-AV1116HHWRCVHCVHHWRC1/2"1/2"HCHCVHCVHC1/2"1/2"2"2"1/2"1/2"2"1 1/2"1 1/2"2"2"2"1/2"V2"1 1/2"2"HHWRCHCV1/2"2"1/2"2"3/4"HWH-12"3/4"1/2"2"3/4"1 1/2"1/2"1 1/2"2"1/2"2"1/2"2"3/4"HWR3/4"3/4"1/2"BF-A1SINK-AHWRV132"13131313131313131313V2"4"3/4"3/4"3/4"2"2"3/4"1 1/2"4"4"2"2"3/4"3/4"3/4"1 1/2"2"1 1/2"1"3/4"2"1/2"1/2"3"1"1"3/4"3/4"1"1"2"2"1/2"1/2"3/4"1/2"2"3/4"1/2"3/4"1/2"2"1 1/2"1"3/4"2"3/4"1 1/2"3/4"1/2"1 1/2"3"3/4"3/4"14133/4"C15REGISTRATION502REGISTRATION502803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:09:11 PMP205FIFTH FLOORPLAN -DOMESTIC02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGN3/16" = 1'-0"1FIFTH FLOOR PLAN - DOMESTICGENERAL NOTES:1. PROVIDE SHUT-OFF VALVES ON ALL COLD AND HOT BRANCH LINES, NOT ALL VALVES CAN BE SHOWN DUE TO SCALE OF DRAWINGS.2. PROVIDE A PRESSURE REDUCING VALVE (PRV) ON DOMESTIC RISERS WHEN PRESSURES EXCEED 65 PSI.3. COORDINATE DOMESTIC OR VENT PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.DRAWING NOTES:1DROP 1/2" HOT AND COLD AND 1 1/2" VENT TO SINK/LAVATORY. 1 1/2" WASTE DOWN.24" VENT DOWN.3DROP 1 1/2" COLD TO WATER CLOSET.4DROP 3/4" HOT AND COLD TO MOP SERVICE SINK. PROVIDE CHECK VALVES IN SUPPLY LINES.5DROP 1/2" COLD AND 1 1/2" VENT TO ELECTRIC WATER COOLER. 1 1/2" WASTE DOWN.6DROP 1/2" COLD AND 1 1/2" VENT TO BOTTLE FILLER. 1 1/2" WASTE DOWN.74" VENT DOWN, 4" VENT THROUGH ROOF.84" COLD DOWN.9PROVIDE DECK MOUNTED EYEWASH (EW-A) AT SINK AS SPECIFIED. REFER TO DETAIL DRAWING(S).10DOMESTIC WATER HEATER (HWH-1). REFER TO DETAIL DRAWING(S).112" VENT DOWN.124" VENT THROUGH ROOF.13PROVIDE BALANCING VALVE ARRANGEMENT. REFER TO DETAIL DRAWING(S).14DROP 1/2" HOT & 1 1/2" COLD AND PROVIDE SHUT-OFF VALVES IN ACCESS PANEL (BY PLUMBING CONTRACTOR). ACCESS PANEL SHALL BE LOCATED IN WALL 48" ABOVE THE FINSHED FLOOR AND OPEN TO THE CORRIDOR.153/4" COLD UP TO NON-FREEZE ROOF HYDRANT WITH GALVANIZED CASING AND ADJUSTABLE FLOW WHEEL LOCK HANDLE WITH DECK FLANGE AND UNDER DECK CLAMP EQUAL TO JAY R SMITH MODEL 5906-H. PROVIDE VACUUM BREAKER. 1/8”DRAIN HOLE MUST BE PIPED AND DISCHARGED TO AN ACCPETABLE DISHCARGE POINT.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 REF.12345ABCE3.8F3.9WASTEHOLDING136STAFFBREAK133SOILED132CLEANSUPPLY134REGISTRATION124PUBLICTOILET100AEVS109EXAM121EXAM120SOILEDWORK111EXAM112EXAM115EXAM114PoSPATIENTTOILET105CCLEANLINENHOLDING137TRIAGE/INTERVIEW106STAFFTOILET103EXAM116STORAGE144WATERSERVICE146SUPPLYCHAINAREA138EVSSUPPLY&EQUIPMENT139EXAM118MAINELECTRICAL142EMERGENCYEQUIPMENTROOM141MAINSERVER140VESTIBULE100V2VESTIBULE100V1HOLDING/MAIL100CCIRCULATION105CIRCULATION105VITALSALCOVE105ASUB-WAITING105BSTAIR2ST2-1CIRCULATION105CORRIDOR12222IW31111111111111111SPECIMENTOILET127BLOODDRAW130BLOODDRAW129BLOODDRAW(PoS)128WAITING/CIRCULATION123CORRIDOR135LABORATORY126STAFFTOILET131MAINLOBBY100EVS125RADIOLOGY(X-RAY)119CORRIDOR143TREATMENT117EXAM113STATLAB/MED110CLEANHOLDING107SHAREDPROVIDEROFFICE104STAFFBREAK102BUILDINGMAINTENANCETOILET/SHOWER138A1VISITORTOILET101ARECEPTION101BLOBBY/WAITING1011112"2"2"1111IWIWIW3/4"3/4"3/4"3/4"IW3/4"3/4"44IW3/4"3/4"443/4"3/4"4IW3/4"IW3/4"3/4"3/4"5IWIW3/4"3/4"3/4"4IW43/4"IW3/4"3/4"4IW3/4"IW 3/4"3/4"41IWIWIW3/4"3/4"3/4"443/4"4IW3/4"3/4"5PUBLICTOILET100BMECHANICAL145CORRIDOR1433/4"13/4"42"803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:09:24 PMP301FIRST FLOORPLAN -INDIRECTWASTE02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1FIRST FLOOR PLAN - INDIRECT WASTENDRAWING NOTES:1CONNECT 3/4" INDIRECT WASTE TO HEAT PUMP (BY MECHANICAL CONTRACTOR). REFER TO DETAIL DRAWING(S).2SUMP PUMP IN ELEVATOR SHAFT. REFER TO DETAIL DRAWING(S). PROVIDE 2" INDIRECT WASTE AS SHOWN.3TERMINATE 2" INDIRECT WASTE 6" ABOVE FLOOD RIM OF MOP SERVICE SINK.DROP 3/4" INDIRECT WASTE IN WALL AND CONNECT TO SINK/LAVATORY TAILPIECE UPSTREAM OF TRAP. REFER TO DETAIL DRAWING(S).45TERMINATE 3/4" INDIRECT WASTE 6" ABOVE FLOOD RIM OF MOP SERVICE SINK.GENERAL NOTES:1. COORDINATE CONDENSATE PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABCE3.8F3.9PUBLICTOILET200APUBLICTOILET200BSTAFFTOILET205EXAM210EXAM211EXAM212EXAM215EXAM216EXAM217EXAM(GYN)218SHAREDCLEANWORK/MEDPREP219EXAM(GYN)PoS220PATIENTTOILET222VISITORTOILET(PoS)224DENTALTREATMENTROOM225DENTALEQUIPMENTSTERILIZATION227SHAREDSOILEDHOLDING229SHAREDEQUIPMENTSTORAGE231EVS226VITALSALCOVE223STAIRST2-2CORRIDOR23211111111111111111111RESPITE/LACTATION240STAFFTOILET237STAIR2ST2-1MAINLOBBY100RESPITE/MEDITATION241OFFICE238UnoccupiedUnoccupiedCIRCULATION228DENTALOFFICE230WAITING201SHAREDMULTIPURPOSE/CONSULT/TELEMED206SHAREDRECEPTION/REGISTRATION202SHAREDCLERICALOFFICE203CIRCULATION207NURSE214PHYSICIANOFFICE/DICTATION213LAB221MANAGEROFFICE209SHAREDSTAFFBREAK208MULTIPURPOSE/CONSULT/TELEMED204EDUCATION/CONFERENCE234IT/ELEC2431111IWIW3/4"3/4"3/4"3/4"3/4"3/4"223/4"2IWIW3/4"3/4"IWIW23/4"3/4"23/4"2IW 3/4"3/4"2IW3/4"IW3/4"3/4"3/4"IW3/4"IW3/4"IW3/4"2IW3/4"IW3/4"3/4"3/4"3/4"2IWIWIW3/4"3/4"3/4"2IW23/4"2TELMED233STAFFBREAK242STAFFBREAK242RESPITE/LACTATION239STAFFTOILET236MULTIPURPOSE/ACTIVITY235WALKINGTRACK200STAIR1ST1-2803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:09:35 PMP302SECONDFLOOR PLAN -INDIRECTWASTE02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1SECOND FLOOR PLAN - INDIRECT WASTEDRAWING NOTES:1CONNECT 3/4" INDIRECT WASTE TO HEAT PUMP (BY MECHANICAL CONTRACTOR). REFER TO DETAIL DRAWING(S).2DROP 3/4" INDIRECT WASTE IN WALL AND CONNECT TO SINK/LAVATORY TAILPIECE UPSTREAM OF TRAP. REFER TO DETAIL DRAWING(S).NGENERAL NOTES:1. COORDINATE CONDENSATE PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8ELEC/DATA323NURSEWORKAREA317BSTAIR2ST2-1STAIR1ST1-31111111EXAM/CONSULT315EXAM/CONSULT314EXAM/CONSULT313CENTRALCLEANWORK312CENTRALSOILEDWORK311EXAM/CONSULT309EXAM/CONSULT308EXAM/CONSULT307EXAM/CONSULT306SPECIALTYEXAM/TREATMENT303PATIENTTOILET302REGISTRATION301OFFICEMANAGER301ASTAFFBREAKAREA305CIRCULATION304CIRCULATION304PUBLICTOILET300BPUBLICTOILET300AGUESTWAITING/CIRCULATION300REGISTRATION301CIRCULATION304CIRCULATION304EXAM/CONSULT322EXAM/CONSULT321EXAM/CONSULT320EXAM/CONSULT319EXAM/CONSULT318PROVIDEROFFICE317ATRIAGENURSE324PATIENTTOILET326ASTAFFTOILET325SPECIALTYEXAM/TREATMENT326PATIENTTOILET327CIRCULATION304EXAM/CONSULT329EXAM/CONSULT331LABDRAW332SPECIMENCOLLECTION333EXAM/CONSULT328NURSEWORK339EXAM/CONSULT328LAB334PATIENTTOILET335ASPECIALTYEXAM/TREATMENT/TELEMED335PATIENTTOILET336TRIAGENURSE339BEXAM/CONSULT327EVS330PROVIDEROFFICE339A11111111111111111111222111IW3/4"3/4"3/4"3/4"IWIW3/4"3/4"3/4"3/4"3/4"223/4"3/4"IW2IW3/4"2IW3/4"213/4"IW23/4"3/4"IW23/4"123/4"IW3/4"3/4"IW3/4"IW2IW3/4"223/4"23/4"IW3/4"3/4"3/4"3/4"3/4"3/4"IWIW22IW3/4"3/4"IW23/4"3/4"IWIW3/4"3/4"EXAM/CONSULT316STAFFCIRCULATION317STAFFTOILET305AREGISTRATION3013/4"13/4"803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:09:47 PMP303THIRD FLOORPLAN -INDIRECTWASTE02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1THIRD FLOOR PLAN - INDIRECT WASTENDRAWING NOTES:1CONNECT 3/4" INDIRECT WASTE TO HEAT PUMP (BY MECHANICAL CONTRACTOR). REFER TO DETAIL DRAWING(S).2DROP 3/4" INDIRECT WASTE IN WALL AND CONNECT TO SINK/LAVATORY TAILPIECE UPSTREAM OF TRAP. REFER TO DETAIL DRAWING(S).GENERAL NOTES:1. COORDINATE CONDENSATE PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8PATIENTTOILET444SHAREDCONFERENCE433PATIENTTOILET418BELEC/DATA430NURSE/TECHSTATION411PATIENTTOILET413MAMMOGRAPHY427STAFFTOILET414EQUIPMENTSTORAGE431APATIENTTOILET424APATIENTTOILET(PoS)423APATIENTTOILET415AHOLDINGBAY1412ACIRCULATION406PATIENTTOILET407BPUBLICTOILET400BPUBLICTOILET400ASTAFFTOILET445EVS439STAIR1ST1-3STAIR2ST2-111111111111111111111121PROCEDUREROOM442STAFFBREAK443PROCEDUREROOM441CIRCULATION435SOILEDWORKROOM438PROCEDUREROOM440RECEPTION436WAITING434PROVIDEROFFICE436ACLEANWORKROOM&EQUIP.STORAGE437ELEVATORLOBBY&PUBLICCORRIDOR400IMAGINGGUESTLOUNGE/WAITING401WHEELCHAIRSTORAGE400CREGISTRATION402WOMEN'SCIRCULATION407GOWNING2407CGOWNING3407DSTAIR3ST3-4GOWNING1407AWOMEN'SCIRCULATION425ULTRASOUND(GUIDEDBIOPSY)415ULTRASOUND424ULTRASOUND(PoS)423DIAGNOSTICRADIOGRAPHY416SOILEDWORKROOM420CLEANWORKROOM419MEN'SCIRCULATION422DEXASCAN432MAMMOGRAPHY(STEREOTATICBIOPSY)431READINGROOM426EQUIPMENTSTORAGE&FLEXSPACE421GOWNING418ACIRCULATION412HOLDINGBAY2412BMEN'SSUB-WAIT418MULTIPURPOSE/CONSULT405PRACTICEMANAGER403OFFICE/READING428IMAGINGIT/DATA429EVS417111111111IW3/4"3/4"3/4"3/4"3/4"2IW3/4"2IW3/4"3/4"3/4"3/4"3/4"23/4"3/4"IW3/4"2IW3/4"3/4"IW3/4"2IWIW3/4"3/4"3/4"3/4"IW23/4"3/4"3/4"IW2IW3/4"3/4"3/4"3/4"12IWIW3/4"3/4"3/4"2IW3/4"3/4"2IW3/4"3/4"3/4"2IW3/4"3/4"IW3/4"13/4"2IWIWIW3/4"3/4"3/4"3/4"23/4"IW3/4"3/4"ELEVATORLOBBY&PUBLICCORRIDOR400WOMEN'SSUB-WAIT409RESULTSALCOVE410803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:10:00 PMP304FOURTHFLOOR PLAN -INDIRECTWASTE02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1FOURTH FLOOR PLAN - INDIRECT WASTENDRAWING NOTES:1CONNECT 3/4" INDIRECT WASTE TO HEAT PUMP (BY MECHANICAL CONTRACTOR). REFER TO DETAIL DRAWING(S).2DROP 3/4" INDIRECT WASTE IN WALL AND CONNECT TO SINK/LAVATORY TAILPIECE UPSTREAM OF TRAP. REFER TO DETAIL DRAWING(S).GENERAL NOTES:1. COORDINATE CONDENSATE PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 12345ABC3.8EXAM/CONSULT521EXAM/CONSULT507PROVIDEROFFICE539ANURSEWORK539EXAM/CONSULT528EXAM/CONSULT529PATIENTTOILET527CIRCULATION504SPECIALTYEXAM/TREATMENT526PATIENTTOILET526ASTAFFTOILET525TRIAGENURSE524IT/ELEC523PROVIDEROFFICE517FNURSEWORKAREA517EEXAM/CONSULT518EXAM/CONSULT519EXAM/CONSULT520EXAM/CONSULT522EXAM/CONSULT513CIRCULATION504BBEXAM/CONSULT514EXAM/CONSULT515EXAM/CONSULT516STAFFCIRCULATION517PROVIDEROFFICE517ANURSEWORKAREA517BEXAM/CONSULT509EXAM/CONSULT508SPECIALTYEXAM/TREATMENT506STAIRVESTIBULE504ASTAFFBREAKAREA505OFFICEMANAGER502APATIENTTOILET503PUBLICTOILET501APUBLICTOILET501BSPECIMENCOLLECTION533LABDRAW532LAB534PATIENTTOILET535ASPECIALTYEXAM/TREATMENT/TELEMED535ELEVATORCONTROLROOM500EXAM/CONSULT537PATIENTTOILET536TRIAGENURSE539BEXAM/CONSULT531REGISTRATION502STAIR1ST1-3PATIENTVITALSALCOVE510STAIRST2-2STAFFTOILET505AUnoccupiedUnoccupiedSTAFFCIRCULATION517CENTRALSOILEDWORK511EXAM/CONSULT5381111111111111111111111111111111IW23/4"3/4"3/4"IWIW2123/4"IW23/4"23/4"IW3/4"213/4"IW23/4"3/4"IW3/4"3/4"3/4"3/4"3/4"23/4"IW3/4"2IW3/4"2IW3/4"IW3/4"2IW3/4"3/4"3/4"23/4"223/4"2IW3/4"23/4"3/4"1213/4"3/4"3/4"3/4"IWIWIW3/4"IW3/4"3/4"223/4"IWIWIW3/4"3/4"3/4"GUESTWAITING/CIRCULATION501CENTRALCLEANWORK512CIRCULATION504ELEVA500EAELEVB500EBSTAIR1ST1-5IW3/4"IW13/4"3/4"803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:10:13 PMP305FIFTH FLOORPLAN -INDIRECTWASTE02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"1FIFTH FLOOR PLAN - INDIRECT WASTENDRAWING NOTES:1CONNECT 3/4" INDIRECT WASTE TO HEAT PUMP (BY MECHANICAL CONTRACTOR). REFER TO DETAIL DRAWING(S).2DROP 3/4" INDIRECT WASTE IN WALL AND CONNECT TO SINK/LAVATORY TAILPIECE UPSTREAM OF TRAP. REFER TO DETAIL DRAWING(S).GENERAL NOTES:1. COORDINATE CONDENSATE PIPING LOCATIONS WITH HEAT PUMPS. NO PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 EXHIBIT "II" - EQUIPMENT INSULATION MATERIALS(NOTES ARE AT END OF EXHIBIT)SERVICEINSULATION MATERIALTHICKNESSREMARKSDOMESTIC HOT WATER TANKSCALCIUM SILICATEOR6 LB. FIBERGLASS SUITABLE FOR 450°SERVICE1-1/2" SEGMENTEDBLOCKS OR MOLDED SECTIONSSECURE BLOCKS WITH GALVANIZED STEEL BANDS, 12" O.C. SECURE FIBERGLASS WITH PINS, STUDS, OR CLIPS, THENAPPLY 2" GALVANIZED HEXAGON MESH WIRE. COVER WITH 1/4" LAYER INSULATING CEMENT. RECOVER - SEE NOTE 1DOMESTIC WATER PUMPSFLEXIBLE SHEETS1/2"INSTALL ON "BOX" FRAMING PER MANUFACTURER'S CONSTRUCTIONSPECIFICATIONS. ARRANGE FOR EASY REMOVAL AND REPLACEMENT. COAT WITH WHITE FINISHWHERE REQUIRED, PROVIDE WELDED STUDS, CLIPS OR ANGLES AS ANCHORS FOR BANDS, WIRES AND MESH.EXHIBIT "I" - PIPE INSULATION MATERIALS(NOTES ARE AT END OF EXHIBIT)SERVICEINSULATION MATERIALTHICKNESSREMARKSDOMESTIC COLD WATERGLASS FIBER ORFLEXIBLE1-1/2" AND LARGER.....1"1-1/4" AND SMALLER.....1/2"SEE NOTE 2DOMESTIC HOTAND CIRCULATION WATER(UP TO 140°)GLASS FIBER ORFLEXIBLE1-1/2" TO 8".....1-1/2"1-1/4" AND SMALLER.....1"RUNOUTS.....1"DOMESTIC HOTAND CIRCULATION WATER(OVER 140°)GLASS FIBER1-1/2" TO 8".....2"1-1/4" AND SMALLER.....1-1/2"RUNOUTS.....1-1/2"AC UNITS DRAINSAND OVERFLOWS(INDIRECT WASTE)ALL SIZES.....1/2"ROOF CONDUCTOR LINESGLASS FIBERALL SIZES.....1"INSULATE BODY OF DRAIN AND CONDUCTOR PIPING, HORIZONTAL [AND VERTICAL] DOWN TOCONNECTION BELOW GROUND FLOOR SLAB OR IN CRAWL SPACENOTES FOR EXHIBIT INOTE 1:EXPOSED INSULATION SHALL BE COVERED WITH A PVC JACKET.FLEXIBLE ALLOWED IN 1/2 IN. THICKNESS ONLY.NOTE 2:NOTES FOR EXHIBIT IINOTE 1:HANGER SPACINGPIPING MATERIALMAXIMUM HORIZONTALSPACING (FEET)MAXIMUM VERTICALSPACING (FEET)ACRYLONITRILE BUTADIENE STYRENE(ABS) PIPING410ALUMINUM TUBING1015BRASS PIPE1010CAST-IRON PIPE515CHLORINATED POLYVINYL CHLORIDE(CPVC) PIPE AND TUBING,1 INCH AND LARGER310CHLORINATED POLYVINYL CHLORIDE(CPVC) PIPE AND TUBING, 1 1/4" INCHES AND LARGER410COPPER OR COPPER-ALLOY PIPE 12 10COPPER OR COPPER-ALLOY TUBING,1 1/4 -INCH DIAMETER ANDSMALLER610COPPER OR COPPER-ALLOY TUBING 1 1/2 -INCH DIAMETER ANDLARGER10 10CROSS-LINKED POLYETHYLENE (PEX)PIPE2.67(32 INCHES)10CROSS-LINKED POLYETHYLENE/ALUMINUM/CROSS-LINKEDPOLYETHYLENE (PEX-AL-PEX) PIPE2.67(32 INCHES)4LEAD PIPECONTINUOUS4POLYETHYLENE/ALUMINUM/POLYETHYLENE (PE-AL-PE) PIPE2.67(32 INCHES)4POLYETHYLENE OF RAISEDTEMPERATURE (PE-RT) PIPE2.67(32 INCHES)10POLYPROPYLENE (PP) PIPE ORTUBING 1 INCH AND SMALLER2.67(32 INCHES)10POLYPROPYLENE (PP) PIPE ORTUBING, 1 1/4 INCHES AND LARGER410POLYVINYL CHLORIDE (PVC) PIPE410STAINLESS STEEL DRAINAGE SYSTEMS 10 10STEEL PIPE1215MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPESFIXTUREMINIMUM PIPE SIZE (INCH)BATHTUBS (60"x32" AND SMALLER)1/2BATHTUBS (LARGER THAN 60"x32") 1/2BIDET3/8COMBINATION SINK AND TRAY1/2DISHWASHER, DOMESTIC1/2DRINKING FOUNTAIN3/8HOSE BIBBS1/2KITCHEN SINK1/2LAUNDRY, 1, 2, OR 3 COMPARTMENTS1/2LAVATORY3/8SHOWER, SINGLE HEAD1/2SINKS, FLUSHING RIM3/4SINKS, SERVICE1/2URINAL, FLUSH TANK1/2URINAL, FLUSHOMETER VALVE3/4WALL HYDRANT1/2WATER CLOSET, FLUSH TANK3/8WATER CLOSET, FLUSHOMETER TANK3/8WATER CLOSET, FLUSHOMETER VALVE1WATER CLOSET, ONE PIECE1/2MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES ANDFIXTURE FITTINGSPLUMBING FIXTURE OR FIXTURE FITTINGMAXIMUM FLOW RATE ORQUANTITYLAVATORY, PUBLIC 0.5 GPM AT 60 PSISHOWER HEAD 1.8 GPM AT 80 PSISINK FAUCET 1.5 GPM AT 60 PSIURINAL0.5 GALLON PER FLUSHINGCYCLEWATER CLOSET1.28 GALLONS PER FLUSHINGCYCLEa. THE MAXIMUM HORIZONTAL SPACING OF CAST-IRON PIPE HANGERS SHALLBE INCREASED TO 10 FEET WHERE 10-FOOT LENGTHS OF PIPE AREINSTALLED.b. FOR SIZES 2 INCHES AND SMALLER, A GUIDE SHALL BE INSTALLED MIDWAYBETWEEN REQUIRED VERTICAL SUPPORTS. SUCH GUIDES SHALL PREVENTPIPE MOVEMENT IN A DIRECTION PERPENDICULAR TO THE AXIS OF THE PIPE.a.b.CONSUMPTION TOLERANCES SHALL BE DETERMINED FROM REFERENCED STANDARDS.a. WHERE THE DEVELOPED LENGTH OF THE DISTRIBUTION LINE IS 50FEET OR LESS, AND THE AVAILABLE PRESSURE AT THE METER IS 35PSI OR GREATER, THE MINIMUM SIZE OF AN INDIVIDUAL DISTRIBUTIONLINE SUPPLIED FROM A MANIFOLD AND INSTALLED AS PART OF APARALLEL WATER DISTRIBUTION SYSTEM SHALL BE ONE NOMINAL TUBESIZE SMALLER THAN THE SIZES INDICATED.CONDENSATE DRAIN SIZINGEQUIPMENT CAPACITYMINIMUM CONDENSATE PIPEDIAMETER (INCH)UP TO 20 TONS OF REFRIGERATION 3/4 INCHOVER 20 TONS TO 40 TONS OF REFRIGERATION 1 INCHOVER 40 TONS TO 90 TONS OF REFRIGERATION1 1/4 INCHOVER 90 TONS TO 125 TONS OF REFRIGERATION 1 1/2 INCHOVER 125 TONS TO 250 TONS OF REFRIGERATION 2 INCHSIZE OF PIPE IDENTIFICATIONPIPE DIAMETER(INCHES)LENGTHBACKGROUND COLORFIELD (INCHES)SIZE OF LETTERS(INCHES)3/4 TO 1 1/480.51 1/2 TO 280.752 1/2 TO 6 12 1.258 TO 10 24 2.5OVER 10 32 3.5WHERE USED, IDENTIFICATION TAPE SHALL BE AT LEAST 3 INCHES (76MM) WIDEAND HAVE WHITE OR BLACK LETTERING ON A PURPLE FIELD STATING "CAUTION:NONPOTABLE WATER - DO NOT DRINK" IDENTIFICATION TAPE SHALL BEINSTALLED ON TOP OF NONPOTABLE RAINWATER DISTRIBUTION PIPES, FASTENEDAT LEAST EVERY 10 FEET (3048 MM) TO EACH PIPE LENGTH AND RUNCONTINUOUSLY THE ENTIRE LENGTH OF THE PIPE.SLOPE OF HORIZONTAL DRAINAGE PIPESIZE(INCHES)MINIMUM SLOPE(INCH PER FOOT)2 1/2 OR LESS 1/43 TO 61/88 OR LARGER1/16MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENTSIZE OF TRAP(INCHES)SLOPE(INCHES PER FOOT)DISTANCE FROM TRAP(FEET)1 1/41/451 1/21/4621/4831/81241/816COMMON VENT SIZESPIPE SIZE(INCHES)MAXIMUM DISCHARGE FROM UPPER FIXTURE DRAIN(DFU)1 1/21242 1/2 TO 36WASTE STACK VENT SIZESTACK SIZE(INCHES)MAXIMUM NUMBER OF DRAINAGE FIXTURE UNITS(DFU)TOTAL DISCHARGE INTOONE BRANCH INTERVALTOTAL DISCHARGE FORSTACK1 1/2122242 1/2NO LIMIT83NO LIMIT244NO LIMIT505NO LIMIT756NO LIMIT100STORM DRAIN SIZINGPIPE SIZE(INCHES)CAPACITY (GPM)VERTICALDRAINSLOPE OF HORIZONTAL DRAIN1/16 INCH PER FOOT 1/8 INCH PER FOOT 1/4 INCH PER FOOT 1/2 INCH PER FOOT234152231443873955791114180811151632315311117165234331653824334448768981,1175057141,0101,42910 2,0509271,3111,8552,62312 3,2721,4802,0932,9604,18715 5,5432,5083, 5465,0167,093THE FLUSH VOLUME FOR A DUAL-FLUSH WATER CLOSET IS DEFINED AS THE COMPOSITE, AVERAGE FLUSH VOLUME OF TWO REDUCED FLUSHES AND ONE FULL FLUSHHOT WATER PIPING VOLUME AND MAXIMUM PIPING LENGTHSNOMINAL PIPE SIZE (INCHES)MAXIMUM PIPING LENGTH (FEET)VOLUME (LIQUID OUNCES PER FOOT LENGTH)PUBLIC LAVATORY FAUCETSOTHER FIXTURES AND APPLIANCES1/4 0.33 6 505/16 0.5 4 503/8 0.75 3 501/2 1.52435/821323/430.5217/840.516150.5131 1/480.581 1/2110.562 OR LARGER180.54NOTE:FIXTURE/EQUIPMENT SIZES NOTED ABOVE SHALL BE USED UNLESS OTHERWISE NOTED.FIXTURE CONNECTION SCHEDULEITEMHOT(H)COLD(C)SANITARY/WASTE(W)VENT(V)COMMENTSWATER CLOSET (VALVE)WATER CLOSET (TANK)URINALLAVATORYMOP SERVICE SINKSINKCLINICAL SERVICE SINKSHOWERTUBELECTRIC WATER COOLERHOSE BIBBWALL HYDRANTFLOOR DRAINWASHING MACHINE FITTING1 1/2"1/2"3/4"1/2"3/4"1/2" 1/2"1 1/2"1/2"1/2"1/2"3/4"3/4"1/2"1/2"3/4"1/2"1/2"4"4"2"1 1/2"3"1 1/2"3"2"2"3"1 1/2"2"2"2"2"1 1/2"1 1/2"2"2"2"2"PROVIDE CHECK VALVES ON SUPPLY LINES1 1/2"2"2"SANITARY/WASTE GLASS FIBER ALL SIZES.....1" INSULATE IN PARKING GARAGESGLASS FIBER ORFLEXIBLESEE NOTE 2EXHIBIT "A" - PIPING MATERIALS (PLUMBING)(NOTES AT END OF EXHIBIT "A")SERVICEPIPE MATERIALFITTINGSCONNECTIONSWATER SERVICEFIRE SERVICEDUCTILE IRONWITH CEMENT LININGBELL & SPIGOTMECHANICAL OR GROOVED RUBBER GASKETDOMESTIC WATER INTERIOR:LOW TEMP HOT (<120°), COLD ANDCIRCULATION (<120°) 3" AND SMALLERTYPE L COPPERWROUGHT COPPER (USE LONGRADIUS ELBOWS ONLY FOR HWRLINE; SHORT RADIUS ELBOW ARENOT ACCEPTABLE)NO-LEAD SOLDER, PRO-PRESSDOMESTIC WATER INTERIOR:HIGH TEMP HOT (>140°), COLD, ANDCIRCULATION (>140°) 3" AND SMALLERTYPE L COPPERWROUGHT COPPER (USE LONGRADIUS ELBOWS ONLY FOR HWRLINE; SHORT RADIUS ELBOW ARENOT ACCEPTABLE)NO-LEAD SOLDER, PRO-PRESSDOMESTIC WATER INTERIOR:HOT, COLD, AND CIRCULATION 4" AND LARGERSCHEDULE 40,GALVANIZED STEEL,TYPE L COPPERGALVANIZED STEEL,WROUGHT COPPERTHREADED, NO-LEAD SOLDERSANITARY, SANITARY VENT,AND STORM(BURIED)PVC PVC SOLVENT WELDEDSANITARY, AND SANITARY VENT, AND STORM (NOT BURIED)SERVICE WEIGHT ORHUBLESS CAST IRON SOIL PIPE OR TYPE DWV COPPER ORSCHEDULE 40, GALVANIZED STEEL (GROOVED)CAST IRON HUBAND SPIGOT, NO-HUBORWROUGHT COPPER;GALVANIZED DRAINAGELEAD AND OAKUM, NO-HUB NEOPRENE GASKET ANDSTAINLESS STEEL CLAMP ASSEMBLY OR NO-LEAD SOLDER; THREADED; GROOVED MECHANICALINDIRECTWASTETYPE DWV COPPER WROUGHT COPPER NO-LEAD SOLDERSUMP PUMP DISCHARGE(NON-SEWAGE MATERIAL)TYPE DWVCOPPERWROUGHT COPPERNO-LEAD SOLDERNOTES FOR EXHIBIT ANOTE 1: ALL EXPOSED PIPING WITHIN FINISHED AREAS SHALL BE PAINTED WITH A PRIMER COAT AND TWO FINISH COATS. COLOR PER ARCHITECT/OWNER.NOTE 2: USE LONG RADIUS ELBOWS ONLY FOR HOT WATER RETURN LINES. SHORT RADIUS ELBOWS ARE NOT ACCEPTABLE FOR HOT WATER RETURN LINES.NOTE 3: ON BURIED COATED STEEL PIPE, TAPE ALL JOINTS WITH SCOTCHWRAP #50, 2IN, WIDE, 50% OVERLAP. PROVIDE CATHODIC PROTECTION SYSTEM.NOTE 4: PVC, CPVC AND PEX PIPING SHALL NOT BE USED IN THE FOLLOWING LOCATIONS: MECHANICAL/BOILER ROOMS, COMMERCIAL KITCHENS, COMMERCIAL LAUNDRY ROOMS, CEILINGSPACES THAT ARE UTILIZED AS MECHANICAL SYSTEM RETURN AIR PLENUMS, ROOMS/CLOSETS WITH GAS FIRED EQUIPMENT.NOTES:THE PROJECT IS DESIGNED UNDER THE 2020 NYS STRETCH CODES, 2020 NYS IECC, ASHRAE 90.1-2006, ITHACA GREEN BUILDING POLICY INITIATIVE,WELL BUILDING DESIGN CRITERIA VERSION 2, LEED VERSION 4.1, BASE TAX ABATEMENT AND ENHANCED ENERGY ABATEMENT AS WELL AS THE 2018 FGI REQUIREMENTS FOR OUTPATIENT FACILITIES.INCLUSIVE OF THE PROGRAMS LISTED ABOVE, LEED AND WELL BUILDING CREDITS ARE BEING PURSUED THAT SPECIFICALLY IMPACT THE PLUMBING SCOPE. PIPING MATERIAL, WATER QUALITY, HOT WATER HEATER EFFICIENCY, LEGIONELLA CONTROL, WATER SENSE FIXTURES, FIXTURE WATER CONSUMPTION, ENERGY STAR EQUIPMENT, ETC. CONTRACTOR TO REVIEW ALL REQUIREMENTS PRIOR TO BID, ALL EQUIPMENT AND MATERIALS TO MEET OR EXCEED THE REQUIREMENTS OF THE PROGRAMS LISTED.THIS PROJECT WILL BE COMMISSIONED. REFERENCE SPECIFICATION SECTIONS 220800 AND 019113 FOR COMMISSIONING REQUIREMENTS.803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:10:16 PMP401SCHEDULES02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 FIXTURE SCHEDULEWATER CLOSETSMARKFIXTUREMAKEMODELMOUNTINGTYPEMAXIMUM GPFADAACCESSORIESWC-AELONGATEDWATER CLOSET3043.001FLOORFLUSH VALVEYES2. CHURCH MODEL 9500SSC SEAT (LESS COVER)LAVATORIESMARKFIXTUREMAKEMODELMOUNTINGNOMINAL DIMENSIONS(LxWxD)BOWL SIZE (LxWxD) ADAACCESSORIESLAV-AVITREOUSCHINA LAVATORYKOHLERK-2084WALL20"x18"18"x13"x4-1/8" YES2. JAY R. SMITH SERIES 0700 CARRIER3. MOUNT FIXTURE AT ADA HEIGHT AND PROVIDE BROCAR 500R INSULATION COVERINGSSINKSMARKFIXTUREMAKEMODELMOUNTINGNOMINAL DIMENSIONS(LxW)BOWL SIZE (LxWxD)ADA ACCESSORIESSINK-ASINGLE BOWLACRYLIC-POLYESTER (EXAM ROOMS)CORIAN ELEMENTS8254LAY-INCOUNTERTOP19-1/2x14-3/818x12-3/4x5 YES1. KOHLER "TAUT" MODEL K-46029-4, SINGLE HOLE DECK MOUNTED FAUCET, ADA, 0.5 GPMSINK-BSINGLE BOWLSTAINLESSSTEEL SINKELKAY"LUSTERTONE"LRAD-1918LAY-INCOUNTERTOP19x1816x11-1/2x6-1/2 YESSINK-CDOUBLE BOWLSTAINLESSSTEEL SINKELKAY"DAYTON"D2251925x19x6-5/1610x14x6-1/8MSS-AMOP SERVICESINKFIATMSB-2424FLOOR24x2424x24x10NO1. CHICAGO MODEL 897-CCP WALL MOUNTED FAUCET & VACUUM BREAKER & PAIL HOOK2. PROVIDE FIAT MODEL 889-CC MOP BRACKET3. PROVIDE FIAT MODEL E-77-AA RIGID VINYL BUMPER GUARDSELECTRIC WATER COOLERS & BOTTLE FILLERSMARK FIXTUREMAKEMODELSINGLE ORDOUBLEWALL ORFLOORRECESSED ORSURFACEHEIGHTWIDTHDEPTHGPH @80°FADA ACCESSORIES1. VOLTS - 1152. Hp - 1/53. Hz - 604. SINGLE PHASESHOWERS AND TUBSMARK FIXTURE MAKEMODELMATERIAL WIDTH DEPTH HEIGHT ADAACCESSORIESSHR-ASHOWERCOMFORT DESIGNSST 3838 TR RRF .75GEL COAT 38-1/2"37-3/16"79" YES2. AMERICAN STANDARD RU101SS FLASH ROUGH VALVE 1. AMERICAN STANDARD HAND HELD SHOWER SYSTEM MODEL TU662SG.213, ADA 1.5 GPMPUMPSMARKTYPEQTY. LOCATION SERVICE FLUIDGPM HEADHP VOLTS PHASE MAKE MODELREMARKSESP-1ELEVATOR SUMPPUMP(SUBMERSIBLE)2ELEVATORINDIRECT WASTESYSTEMWATER50 25 FT 3/41151ELV290WATER HEATERSMARK TYPEQTY. LOCATIONGAL. WIDTH HEIGHTVENTVOLT WATT H&C MAKE MODELREMARKS---2083/4"EXPANSION TANKSMARK SERVICE LOCATION TYPETANK VOLUME CONNECTION SIZE MAX PRESS MEAN OPERATING TEMP. CHARGEMAKE MODEL ASMEGALLON INCHES PSIDEG. FPSIMIXING VALVESMARK LOCATIONCvMIN. FLOW COLD EWT HOT EWT LWT MAX PDMAKE MODEL REMARKSGPM DEG. F DEG. F DEG. F@ HOT WATER HEATERSPOWERS LFLM492-23. PROVIDE 2" SHOWER DRAIN, SEAT, REINFORCED GRAB BARSMV-11. PROVIDE TWO (2) MIXING VALVES PIPED IN PARALLEL (PER FLOOR) AT EACH HOT WATER HEATER FOR BETTER FLOW RATE AND LOW FLOW CONTROL4500HPA082KDLOCHINVAR8027" 69"MINIMUM DIAMETER AND MAXIMUM LENGTH OF INDIVIDUAL BRANCH FIXTURE VENTS AND INDIVIDUAL FIXTURE HEADER VENTS FOR SMOOTH PIPESDIAMETER OFVENT PIPE(INCHES)INDIVIDUAL VENT AIRFLOW RATE (CUBIC FEET PER MINUTE)MAXIMUM DEVELOPED LENGTH OF VENT (FEET)12345678910 11 12 13 14 15 16 17 18 19 201/2 952513854321111111111113/4 100 88 47 30 20 15 1097654333222211--10094654837292420171412119877661 1/4-------1008773625346403632292623211 1/2-----------10096847565605449452-------------------100HWRP-1HOT WATERRECIRCULATIONMECHANICALROOMDOMESTIC WATERSYSTEMWATER 15 31 FT 1/6 1151MAGNA 1 32-100 FNEFFENERGY STARAMERICAN STANDARD"MADERA"1.28EWC-A8YES19"ELECTRICWATERCOOLERELKAY WALLSURFACELZSTL8WSVR DOUBLEH- 38-3/8"L- 32-7/8"35-3/4"1. SLOAN "SLOAN-OPTIMA" MODEL 111-YO-1.28 ES-S TMO (SENSOR, HARD WIRE), ADA , 1.28 GPFDBP-1DOMESTIC BOOSTER PUMP(DUPLEX SYSTEM)1MECHANICALROOMDOMESTIC WATERSYSTEMWATER 226 35 PSI7-1/2 2083GRUNDFOSMPC-E 2CRE32-2-11. PROVIDE GRUNDFOS CU352 ENERGY SAVING PUMP MANAGEMENT UNITHWH-1HEAT PUMP ELECTRICWATER HEATER5 REFER TO FLOOR PLANS (1 PER FLOOR)1. PROVIDE HEAT TRAPS AS REQUIRED BY CODE2. PROVIDE INLET AND OUTLET OUTDOOR AIR KIT AND DUCT ADAPTORS3. FINAL ELECTRICAL CONNECTIONS BY ELECTRICAL CONTRACTORDET-1 DOMESTICMECHANICALROOMVERTICAL 4.5WATTS DET-12-M1FIELD CHARGE TO MATCH SYSTEM PRESSURE140.01503/4"ASMENOREMARKSNO LIBERTY1. SUBMERSIBLE SUMP PUMP WITH OIL-TECTOR CONTROLGRUNDFOSEYEWASHESPOWERS ES150MV-24040110851401101. VOLTS - 1152. Hp - 1/53. Hz - 604. SINGLE PHASEBF-A8YES5-3/8"BOTTLE FILLERELKAY WALL SURFACELZWSSM SINGLEH- 25-7/16"L- 17-15/16"8-3/16"YES1. ELKAY ALLURE SATIN STAINLESS STEEL MODEL LK7921SSS DECK MOUNTED FAUCET, 1.5 GPM, ADA5 1. PROVIDE WHERE NOTED ON THE PLANS - HYDROGUARD XP SERIES EMERGENCY TEMPERING VALVE WITH COLD WATER BYPASS1. ULTRA HIGH EFFICIENCY PUMP WITH AQUASTAT AND PUMP TIMERLAV-B INTEGRAL INTEGRAL------YES2. PROVIDE BROCAR 500R INSULATION COVERINGS1. ELKAY ALLURE SATIN STAINLESS STEEL MODEL LK7921SSS DECK MOUNTED FAUCET, 1.5 GPM, ADA.BY GENERAL CONTRACTORBY GENERAL CONTRACTORSINK-ADEDUCT ALTERNATESINGLE BOWLSTAINLESSSTEEL SINK (EXAM ROOMS)ELKAY"LUSTERTONE"LRAD-221955LAY-INCOUNTERTOP22x19-1/2 18x14x5-3/8 YES1. KOHLER "TAUT" MODEL K-46029-4, SINGLE HOLE DECK MOUNTED FAUCET, ADA, 0.5 GPM1. KOHLER "TAUT" MODEL K-46029-4, SINGLE HOLE DECK MOUNTED FAUCET, ADA, 0.5 GPM1. KOHLER "TAUT" MODEL K-46029-4, SINGLE HOLE DECK MOUNTED FAUCET, ADA, 0.5 GPMLAY-INCOUNTERTOP2. PROVIDE 44 GALLON BLADDER TANK (DBT-1) EQUAL TO THRUSH MODEL WHV 165 0.515 PSI15 PSI13 GPM6.2 GPMSINK-DDOUBLE BOWLSTAINLESSSTEEL SINKDLR291810 29x18 12x12x10NO1. ELKAY ALLURE SATIN STAINLESS STEEL MODEL LK7921SSS DECK MOUNTED FAUCET, 1.5 GPM, ADALAY-INCOUNTERTOPELKAY"LUSTERTONE"SHR-B SHOWER --- --- --- YES2. AMERICAN STANDARD RU101SS FLASH ROUGH VALVE 1. AMERICAN STANDARD HAND HELD SHOWER SYSTEM MODEL TU662SG.213, ADA 1.5 GPM3. PROVIDE 2" SHOWER DRAIN, REINFORCED GRAB BARSTILE BY OTHERTILE BY OTHERTILE BY OTHER4. PROVIDE MUSTEE MODEL 99 DURAPAN UNDER WATER HEATERWC-BELONGATEDWATER CLOSETAMERICAN STANDARD"AFWALL"2257.101.020 WALL FLUSH VALVE 1.3 YES1. SLOAN "SLOAN-OPTIMA" MODEL 111-YO-1.28 ES-S TMO (SENSOR, HARD WIRE), ADA , 1.28 GPF2. CHURCH MODEL 9500SSC SEAT (LESS COVER)3. JAY R. SMITH SERIES 0200-0500 CARRIERNOTES:THE PROJECT IS DESIGNED UNDER THE 2020 NYS STRETCH CODES, 2020 NYS IECC, ASHRAE 90.1-2006, ITHACA GREEN BUILDING POLICY INITIATIVE,WELL BUILDING DESIGN CRITERIA VERSION 2, LEED VERSION 4.1, BASE TAX ABATEMENT AND ENHANCED ENERGY ABATEMENT AS WELL AS THE 2018 FGI REQUIREMENTS FOR OUTPATIENT FACILITIES.INCLUSIVE OF THE PROGRAMS LISTED ABOVE, LEED AND WELL BUILDING CREDITS ARE BEING PURSUED THAT SPECIFICALLY IMPACT THE PLUMBING SCOPE. PIPING MATERIAL, WATER QUALITY, HOT WATER HEATER EFFICIENCY, LEGIONELLA CONTROL, WATER SENSE FIXTURES, FIXTURE WATER CONSUMPTION, ENERGY STAR EQUIPMENT, ETC. CONTRACTOR TO REVIEW ALL REQUIREMENTS PRIOR TO BID, ALL EQUIPMENT AND MATERIALS TO MEET OR EXCEED THE REQUIREMENTS OF THE PROGRAMS LISTED.THIS PROJECT WILL BE COMMISSIONED. REFERENCE SPECIFICATION SECTIONS 220800 AND 019113 FOR COMMISSIONING REQUIREMENTS.803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:10:20 PMP402SCHEDULES02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021 NOTES:PVC PIPING SHALL NOT BE USED WITHIN CEILING SPACES THAT ARE UTILIZED AS MECHANICAL SYSTEM RETURN AIR PLENUMS.3.REFER TO SPECIFICATIONS FOR PIPING AND INSULATION REQUIREMENTS.PLUMBING CONTRACTOR SHALL CONNECT CONDENSATE PIPING TO EACHHVAC UNIT AND PROVIDE HARD PIPED TRAP, FITTINGS AND UNION, AS WELLAS ALL CONDENSATE PIPING.2.1.SLOPE AT 1/4" PER FOOTCONDENSATE DRAIN NIPPLE- FIELD VERIFY SIZE ANDCOORDINATE EXACT LOCATIONWITH HVAC CONTRACTORCONDENSATE WASTE ROUTE ASSHOWN ON PLANSFLEXIBLE TUBING FURNISHED WITH HVAC UNIT.CLAMP ONE END TO UNIT NIPPLE, CLAMP THEOTHER END TO CONDENSATE WASTE PIPING. PROVIDE CLAMPS.DRAIN PAN1" GREATER THAN HALF OFFAN TOTAL STATIC PRESSUREFAN STATICPRESSURE2" MIN.CONDENSATE DRAINS FOR TERMINAL HVAC UNITS SHALL BE PROVIDED BY THIS CONTRACT (UNLESS OTHERWISE NOTED). CONDENSATE DRAINS FOR ALL ROOF MOUNTED EQUIPMENT AND EQUIPMENT PROVIDED IN MECHANICAL ROOMS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR (UNLESS OTHERWISE NOTED).4.FSNOTE: PC TO PROVIDE EZ TRAP MODEL EZT-225 FLOW SWITCH TO SHUT DOWN SYSYTEM ON OVERFLOW.WALL3/4"1 1/2"P-TRAPSINK/LAVWALLFINISHED FLOOR1 1/2"VWIWCONNECT IW TO TAILPIECE (VIA AIR BREAK) UPSTREAM OF TRAPPROVIDE THIS BALANCING VALVE ARRANGEMENT AT EACH LOCATION WHERE MULTIPLE RISERS OR HORIZONTAL LOOPS INTERSECT ON HOT WATER RETURN LINES.FLOWNOTE:CHECK VALVEBALL VALVEBALANCE VALVESIZE AS NOTEDON FLOOR PLANSHWRBALANCING VALVE SIZE:GPM RANGE:3/4"1"1 1/4"1 1/2"2"2 1/2"3"UP TO 3.03.1 - 7.07.1 - 1213 - 2223 - 4546 - 7071 - 1404"141 - 2804" CONC. PADNOTE:P.C. SHALL WIRE LOW PRESSURE SUCTION SWITCH BACKTO PUMP CONTROL PANEL. SWITCH SHALL SHUT DOWNPUMPS IF INCOMING LINE PRESSURE FALLS BELOW 20 PSI4" GATE VALVE (TYP.)4" CHECK VALVE(RESILIENT SEAT)4" SUPPLYLOW PRESSURESUCTION SWITCH SET AT 20 PSIPRESSUREGAUGE (TYP.)ISOLATIONVALVE (TYP.)FLANGE (TYP.)CONTROL PANELALL WORK BY P.C.BALL VALVEUNIONDRAIN VALVEFINISHED FLOORDOMESTICBLADDER TANK(DBT-1)ALL WORK INSIDE BOXPROVIDED AS PART OFFACTORY PACKAGED UNIT4" DISCHARGEAQUASTAT2"4"PRVDBP-1PRV2"DBP-1LIFT CHECK VALVE1 1/2" IW3 3/8"COORDINATE HEIGHT OF PUMPDISCHARGE WITH ELEVATORCONTRACTOR AND FINISHED FLOORELEVATIONRECEPTACLE BY ELECTRIC CONTRACTORTURN ONLEVEL 1"BELOW PITFLOORTURN OFF LEVELELEVATOR SUMP PUMP (ESP-1)UNIONC.O.CAST IRONPIPE SLEEVESEAL WATERTIGHT2" IW. REFER TO PLANSFOR CONTINUATIONPROVIDE LINK-SEAL2"x2"x1 1/2" WYEELEVATORPIT FLOORSHUT OFF VALVE(GATE VALVE)TIGHT TO PIT WALL1 1/2" IW1.BACKFLOW PREVENTER(S) MUST BE A MINIMUM OF 30" ANDMAXIMUM OF 60" ABOVE THE FINISHED FLOOR.2.BACKFLOW PREVENTER(S) INSTALL ABOVE 60", MUST BEPROVIDED WITH AN OSHA APPROVED SCAFFOLD PLATFORM ONSITE FOR REQUIRED TESTING AND INSPECTION OF BACKFLOWDEVICE(S).3. BACKFLOW PREVENTER(S) CLEARANCES:- MINIMUM 36" CLEAR IN FRONT OF DEVICE(S)- MINIMUM 12" CLEAR BEHIND DEVICE(S)- MINIMUM 24" CLEAR ABOVE DEVICE(S)4. DOMESTIC METER HEIGHT LIMITS 18" MIN. - 40" MAX.5.THE BACKFLOW PREVENTER(S) ARE LOCATED IN AN ADEQUATELYHEATED AND LIGHTED AREA TO PREVENT FREEZING AND ALLOWFOR MAINTENANCE AND TESTING OF THE DEVICE(S).NOTES:6. ALL MATERIAL BEFORE BACKFLOW PREVENTER(S) TO BE BRASS, COPPER OR CEMENT LINED DUCTILE IRON. VICTAULIC GROOVED/ROLLED PIPING AND FITTINGS ARE NOT ACCEPTABLE UPSTREAM OF THE BACKFLOW PREVENTER(S).7. AIR GAP FITTINGS ARE NOT ALLOWED.6X4 TEE SLEEVE &SEAL (TYPICAL)6" COMBINEDWATER SERVICEBY FPC6" OS&Y VALVE WITHTAMPER SWITCH30"4" GATE VALVE(TYPICAL)3" METERW/UNIONSPLATESTRAINER4" BYPASSTO FIRESERVICE4"6"4" REDUCED PRESSURE ZONE (RPZ)MAKE: WATTS LF957. PROVIDE A 6x4FUNNEL FITTING CENTERED UNDERRPZ RELIEF VALVE. RPZ RELIEF GAPSHALL BE A MINIMUM OF TWO TIMESTHE RPZ DISCHARGE OPENING4" COLD TOBOOSTER PUMPSPIPESUPPORT TYPICAL)TERMINATE 6" IW AT BLDG'SEXTERIOR 12" ABOVEFINISHED GRADE WITHTURNED DOWN ELBOW,12x12 SPLASH BLOCK, BUGSCREEN AND FLAPPER VALVE.2" REDUCED PRESSURE ZONE (RPZ)MAKE: WATTS LF909. PROVIDE A 6x4FUNNEL FITTING CENTERED UNDERRPZ RELIEF VALVE. RPZ RELIEF GAPSHALL BE A MINIMUM OF TWO TIMESTHE RPZ DISCHARGE OPENING4"TERMINATE 4" IW AT BLDG'SEXTERIOR 12" ABOVEFINISHED GRADE WITHTURNED DOWN ELBOW,12x12 SPLASH BLOCK, BUGSCREEN AND FLAPPER VALVE.30"1. COORDINATE WITH ELECTRICAL CONTRACTOR FOR EXACT REQUIREMENTS.2. PROVIDE INLET AND OUTLET OUTDOOR AIR KIT.3. PROVIDE 24" DEEP HEAT TRAP ON HOT WATER SUPPLY.4. PROVIDE DRAIN PAN UNDER HEATER.5. COORDINATE WITH MECHANICAL CONTRACTOR (INLET/OUTLET DUCT CONNECTIONS).6. STORAGE TEMPERATURE SHALL BE 140 F.7. PROVIDE PRV ON COLD WATER INLET TO HEATER IF PRESSURE EXCEEDS 55 PSI.NOTES:DRAIN PANDRAIN VALVEFINISHED FLOORHEAT PUMP ELECTRIC HOT WATER HEATER(HWH-1)SHUT-OFF VALVE (TYP.)RUN T&P RELIEF VALVE TO ADJACENT MOP SERVICE SINKUNION (TYP.)THERMOMETER (TYP.)2"1"CH 115SPRING CHECK VALVE (TYP.)STRAINER WITHBLOWDOWN VALVEHWR PUMP(HWRP-1 )BALANCING VALVEHWRMIXING VALVE (MV-1)1"3/4"EXPANSION TANK (DET-1)MIXING VALVE (MV-1)1"CHT&P GAUGESET AT 110° F2"PROVIDE PRESSURE REDUCING VALVE (PRV) IF PRESSUVRE EXCEEDS 60 PSI. SET PRV TO 55 PSISPRAY SPRAY HEAD WITH FLIP-TOP DUST COVER, INTERNAL FLOW CONTROL AND FILTER (TYP.OF 2)NOTES:1. PROVIDE GUARDIAN MODEL G5022 DECK MOUNTED EYEWASH (EW-1)2. PROVIDE IN-LINE VACUUM BREAKEREW-ACOUNTERTOPSTAINLESS STEEL SQUEEZE HANDLE WITH PLASTIC COVERNYLON HANDLEPROVIDE SHUT-OFFAND CHECK VALVES AS SHOWN (TYP.)UNION (TYP.)PROVIDE POWERSHYDROGUARD ES150SERIES MIXING VALVE (MV-2)CHTEMPID WATER INLETPROVIDE 1/2" HOT AND 1/2" COLD FROM SINK PIPINGSPRAY SPRAY HEAD WITH FLIP-TOP DUST COVER, INTERNAL FLOW CONTROL AND FILTER (TYP.OF 2)NOTES:1. PROVIDE GUARDIAN MODEL G1819 WALL MOUNTED EYEWASH (EW-2)2. PROVIDE IN-LINE VACUUM BREAKEREW-BPROVIDE SHUT-OFFAND CHECK VALVES AS SHOWN (TYP.)UNION (TYP.)PROVIDE POWERSHYDROGUARD ES150SERIES MIXING VALVE (MV-2)CHTEMPID WATER INLET1/2" HOT AND 1/2" COLD FROM SINK PIPINGINSULATIONFLASHING CLAMPDECK FLANGEUNDER DECKCLAMPSET SCREWS3/4" COLDWATER LINEROOF DECKINGMETAL DECKWATERPROOFINGWATER TIGHTSEALANT53 1/2"17" MIN43" MAX1/8" NPTDRAIN HOLENOTES:1. PROVIDE HYDRANT WITH VACUUM BREAKER.2. DRAIN HOLE SHALL BE PIPED AND DISCHARGED TO ANACCEPTABLE DISCHARGE POINT.803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:10:23 PMP501DETAILS02/05/20212018089WABCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3CONDENSATE DRAIN CONNECTION2INDIRECT CONNECTION TO LAV/SINK4HWR BALANCE VALVE ARRANGEMENT5BOOSTER PUMP6ELEVATOR SUMP PUMP1DOMESTIC WATER SERVICE7HEAT PUMP HOT WATER HEATER8DECK MOUNTED EYEWASH AT SINK9WALL MOUNTED EYEWASH AT MSS10NON-FREEZE ROOF HYDRANTREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021