HomeMy WebLinkAboutM001 Legend & AbbreviationsVDTSTGFSFZHHPSTSTXTVDTDNCCNONCCNOVDSIZEMINMAXCFMSIZEMARK30"x18"18"x18"30"x18"12"x12"12"ø12"x10"ø18"x18"12"ø18"ø12"ø12"x12"12"ø12"x10"ø30"x18"18"ø18"x18"30"x18"18"x18"30"x18"30"x18"18"ø18"x18"12"ø18"ø12"ø12"ø18"ø12"ø18"ø18"x18"18"x18"18"ø18"ø18"ø18"ø12"ø12"ø12"ø12"ø10"ø10"ø12"x18"12"x18"18"x18"18"x18"18"x18"12"x18"12"x18"12"x18"12"x18"18"x18"18"x18"12"ø12"øAADBDDFSFDMDSDDSDNICNOT IN CONTRACTPIPE GUIDEPIPE ANCHOREND CAPAIR SEPARATORDUCT SPLIT - RADIUS ELBOW(SIZE INDICATED)(SIZE INDICATED)DUCT SPLIT - SQUARE ELBOWAND BOURDON TUBEPRESSURE GAUGE WITH GAUGE COCKPRESSURE GAUGE WITH GAUGE COCKFLEXIBLE DUCT (SIZE PER TABLE,THIS SHEET)45° LATERAL, ROUND TO ROUND45° CONICAL LATERAL, ROUND TO ROUNDPUMP - GENERICFLOW METERHUMIDISTAT - WALL MOUNTEDTHERMOSTAT - DUCT MOUNTEDTRANSITION - RECTANGULAR TOSHORT RADIUS ELBOW - 90°RETURN/EXHAUST AIR REGISTER/GRILLESUPPLY AIR DIFFUSER/GRILLELINEAR DIFFUSERTRANSFER AIR DESIGNATIONSUPPLY AIR DESIGNATIONRETURN AIR DESIGNATIONEXHAUST AIR DESIGNATIONRETURN/EXHAUST REGISTER, CEILING ORDUCT MOUNTEDOUTSIDE AIR DUCT (UP AND DOWN)SUCTION DIFFUSERPUMP - END SUCTIONY-STRAINERTHERMOMETERPRESSURE/TEMPERATURE TEST FITTINGUNIONFLEXIBLE CONNECTIONTEE CONNECTION - STRAIGHT, DOWN, AND UPAIR VENT - (MANUAL)AUTOMATIC AIR VENTPIPE UP AND DOWNCONCENTRIC REDUCERPITCH OF PIPE, DROP (D) RISE (R)FLOW SWITCHSINGLE LINE DOUBLE LINEDESCRIPTIONSUPPLY/OUTSIDE AIR DUCTRETURN AIR DUCTSUPPLY/OUTSIDE AIR DUCT ELBOWRECTANGULAR (UP AND DOWN)DENOTES RECTANGULAR OR SQUAREDUCT, SIZE IN INCHESDENOTES ROUND DUCT, SIZE IN INCHESDENOTES FLAT OVAL DUCT, SIZEROUND OR FLAT OVAL DUCT SUPPLY/END OF DUCT (CAPPED)SUPPLY AIR TERMINAL, CEILING OR DUCTMOUNTED, SQUARE & RECTANGULAR(SHADED AREA(S) DENOTE # & DIRECTIONOF BLANKED OFF SECTION(S))SIDEWALL AIR TERMINAL WITH VD(ARROWS DENOTE THROW DIRECTION)IN INCHESRECTANGULAR (UP AND DOWN)RETURN DUCT BELOWSQUARE VANED ELBOW - 90°TRANSITION - CONCENTRICTRANSITION - ECCENTRICDUCT RISE (IN DIRECTION OF ARROW)FREEZESTAT (LOW TEMPERATURE DIRECTOR)THERMOSTAT - WALL MOUNTEDHUMIDISTAT - DUCT MOUNTEDCLOSED CELL FOAM ACOUSTICAL LINING -DUCT DIMENSIONS SHOWN INDICATEINSIDE CLEAR DIMENSIONSSYMBOLDESCRIPTIONNOT ALL SYMBOLS, ABBREVIATIONS AND LINE DESIGNATIONS°FDEGREES FAHRENHEITWITH PILOT LIGHTDDC DIRECT DIGITAL CONTROLSBAS BUILDING AUTOMATION SYSTEM(F) FUTURENEW(N)CRCSPOINT OF CONNECTION BETWEEN NEW AND EXISTING WORKPOINT OF DISCONNECT BETWEEN EXISTING AND TO BE REMOVED WORKSECTION LETTERSECTION DRAWING NUMBERWGWBVTRVRVVIBVIVELWATER GAUGEWET BULBVENT THROUGH ROOFVARIABLE REFRIGERANT VOLUMEVIBRATIONVIBRATION ISOLATORVELOCITYVARIABLE AIR VOLUMEVENT OR VOLTSUNIT VENTILATORUNOCCUPIEDUNLESS NOTED OTHERWISEUNIT HEATERUNDERCUTTOTAL STATIC PRESSURETOTAL PRESSURETOP OF STEELTOP OF PIPETOP OF DUCTTEMPERATURETOILET EXHAUST (FAN)TESTING AND BALANCINGTHERMOSTATSTAINLESS STEELVAVVUVUNOCCUNOUHUCTSPTPTOSTOPTODTEMPTE(F)TABTS.S.SQ FTRHRFREFRCPRASQUARE FEETRELATIVE HUMIDITYRETURN AIR FANREFRIGERANTRADIANT CEILING PANELRETURN AIRHORSEPOWER or HEAT PUMPHAND-OFF SELECTOR SWITCHHAND-OFF AUTOMATIC SELECTOR SWITCHARRESTANCE FILTERHIGH EFFICIENCY PARTICULATEHEAT EXCHANGERHEADHEATING COILHUMIDISTATGRAINS PER POUNDGENERAL CONTRACTORGALLONSGALLONS PER MINUTEGALLONS PER HOURGASFREEZESTATFACE VELOCITYFEET WATER GAUGEFEETFLOW SWITCHFEET PER SECONDFEET PER MINUTEHPH/OHOAHEPAHXHDHCHGR/LBGCGALGPMGPHGFZFVFT/WGFTFSFPSFPMPOLYVINYL CHLORIDEPOUNDS PER SQUARE INCH GAUGEPOUND PER SQUARE FOOTPRESSURE SENSOR DUCT STATICPRESSURE REDUCING VALVEPRESSURE REDUCING DEVICEPREHEAT COILPHASEPRESSURE DROPPLUMBING CONTRACTORPROPYLENE GLYCOLPUMPNATURAL GASOUTSIDE DIAMETEROCCUPIEDOPPOSED BLADE DAMPEROUTSIDE AIR INTAKEOUTSIDE AIRNOT TO SCALENORMALLY OPENNORMALLY CLOSEDPVCPSIGPSFPSPRVPRDPHCPHPDPCP.G.PNGODOCCOBDOAIOANTSNONCMOTOR CONTROL CENTERMECHANICAL CONTRACTOR1000 BTU PER HOURLEAVING WATER TEMPERATURELINEAR FEETPOUNDS PER HOURPOUND(S)LEAVING AIR TEMPERATUREKILOWATTINCHES WATER GAUGEINCHINSIDE DIAMETERHERTZHOT WATERHEATING, VENTILATING, AIR CONDITIONINGHUMIDITY OR HUMIDIFIERHEATERMCCMCMBHLWTLFLB/HRLBLATKWIN/WGINIDHzHWHVACHUMHTRFLAT ON TOPFLAT ON BOTTOMFLOW METERFULL LOAD AMPSFIRE DAMPERFAN COIL UNITFORWARD CURVEDFILTER or FANENTERING WATER TEMPERATUREEXPANSION TANKEXTERNAL STATIC PRESSUREEXHAUST FANELECTRIC DUCT HEATEREVAPORATIVE COOLERELECTRICAL CONTRACTOREXHAUST AIRENTERING AIR TEMPERATUREEXISTINGFOTFOBFMFLAFDFCUFCFEWTETESPEFEDHECECEAEAT(E)DIRECT EXPANSIONDUCT SMOKE DETECTORDOMESTICDOWNDIAMETERDEHUMIDIFIERDUST COLLECTORDRY BULBCONSTANT VOLUMECABINET UNIT HEATERCONDENSING UNITCOOLING TOWERCONDENSATE PUMPCHILLERDXDSDDOMDNDIA./ ØDHDCDBCVCUHCUCTCPCHCUBIC FEET PER MINUTECUBIC FEET PER HOURCOOLING COILCOMBUSTION AIRBRITISH THERMAL UNIT PER HOURBRITISH THERMAL UNITBOTTOM OF PIPEBOTTOM OF DUCTBACKWARD INCLINEBRAKE HORSEPOWERBLAST GATEBACKDRAFT DAMPERBOILERAIR SEPARATORACCESS PANELACOUSTICAL LININGAIR HANDLING UNITABOVE FINISHED FLOORACCESS DOORAIR CONDITIONING UNITCFMCFHCCCABTUHBTUBOPBODBIBHPBGBDDBASAPAL or (L)AHUAFFADACGWRGWSHPWRHPWSHWRHWSCWRCWSGLYCOL WATER RETURNGLYCOL WATER SUPPLYHEAT PUMP WATER RETURNHEAT PUMP WATER SUPPLYHOT WATER RETURNHOT WATER SUPPLYCONDENSER WATER RETURNCONDENSER WATER SUPPLYCHILLED WATER RETURNCHILLED WATER SUPPLYARE NECESSARILY USED ON THIS PROJECT.1.TEMPERATURE SWITCHPRESSURE SWITCHDIFFUSER TAGBUTTERFLY VALVEBALANCE VALVEBALL VALVEPRESSURE REGULATING VALVEPRESSURE RELIEF VALVEPRESSURE REDUCING VALVECHECK VALVETRIPLE DUTY VALVEGATE VALVE2-WAY ELECTRIC VALVE2-WAY PNEUMATIC VALVE3-WAY ELECTRIC VALVE3-WAY PNEUMATIC VALVEVACUUM BREAKERTEMPERATURE ELEMENTTEMPERATURE SENSORTHERMOSTAT W/ GUARD - WALL MOUNTEDTEMPERATURE SENSOR - WALL MOUNTEDEXISTING TO REMAINETRPACKAGED TERMINAL AIR CONDITIONERPTACMV12"Ø(L) 12"x12"(L)AUTOMATIC AIR DAMPERAADBOTTOM OF STEELBOSHEAT RECOVERY UNITHRUPACKAGED TERMINAL HEAT PUMPPTHPVRF VARIABLE REFRIGERANT FLOWSPSHSFSARTURPMRHCSTATIC PRESSURESENSIBLE HEATSUPPLY AIR FANSUPPLY AIRROOFTOP UNITREVOLUTIONS PER MINUTEREHEAT COILAUTO AIR DAMPERBACK DRAFT DAMPERFIRE DAMPERMOTORIZED DAMPERSMOKE DAMPERVOLUME DAMPERCOMBINATION FIRE/SMOKE DAMPERDUCT SMOKE DETECTOREXISTING PIPING/DUCTWORKREMOVAL PIPING/DUCTWORKNEW WORK PIPING/DUCTWORKVAV BOX TAGFUME HOODFHTEMPERATURE TRANSMITTERTTVACUUM BREAKERVBVP VACUUM PUMPEXHAUST AIR DUCT ELBOWRECTANGULAR (UP AND DOWN)EXHAUST AIR DUCT90° CONICAL TAKEOFF, ROUND TO90° TAKEOFF, ROUND TO ROUND,ROUND SHOE TAP90° TAKEOFF, RECTANGULAR TOSTRAIGHT SHOE TAPCFMRASAIR DUCT (UP AND DOWN)ROUND OR FLAT OVAL DUCT RETURNAIR DUCT (UP AND DOWN)ROUND OR FLAT OVAL DUCT EXHAUSTROUNDROUNDTS-00P/TFMRDNOTESMISC. SYMBOLSLINE DESIGNATIONSPIPING SYMBOLSDUCTWORK SYMBOLSABBREVIATIONSAVFCMINIMUM REQUIREDTE-00CONTROLS:A#SDA. UNLESS OTHERWISE SPECIFIED IN THESE DOCUMENTS, ALLEXHAUST AND RELIEF FANS SHALL BE CONTROLLED BY TIME CLOCK,TIME CLOCK PROVIDED BY HVAC CONTRACTOR, CONNECTED TOHAND-OFF-AUTO RELAYS OF FAN MOTOR STARTERS, OR START-STOPOF VFD'S. ALL POWER WIRING OF TIME CLOCK BY HVAC CONTRACT.B. ALL EXHAUST AND RELIEF FANS SHALL HAVE POSITIVE CLOSUREDAMPERS INTERLOCKED TO OPEN WHEN FAN IS ENERGIZED,EXCEPTING SMOKE MANAGEMENT SYSTEMS, DRYER VENTS ANDCOOKING EQUIPMENT.C.ALL DIRECT DRIVE FANS SHALL BE PROVIDED WITH SOLID STATEMOTOR CONTROLLERS OR ELECTRONICALLY COMMUTATED MOTORS(ECM) WITH ALL REQUIRED CONTROL DEVICES FOR SPEEDADJUSTMENT OF THE FAN MOTOR.D.FOR ALL HVAC EQUIPMENT (EXCLUDING SMOKE MANAGEMENTSYSTEMS AND COOKING APPLICATIONS) PROVIDE AN INTERLOCK TOTHE MOTORIZED DAMPER SUCH THAT THE DAMPERS WILL CLOSE UPONUNOCCUPIED CONDITION. HVAC CONTRACT TO PROVIDE TIME CLOCKOR DDC CONTROL.E. EACH ZONE SHALL HAVE A 7 DAY-4 FUNCTION PER DAYPROGRAMMABLE CONTROLLER WITH A 5°F DEADBAND AND SETPOINTOVERLAP RESTRICTIONS.F. MINIMUM AUTOMATIC CONTROLS SHALL SETBACK TO 55°F (HEAT)AND 85°F (COOL); 7-DAY CLOCK, 2-HOUR OCCUPANT OVERRIDE,10-HOUR BACKUP.G. PROVIDE ECONOMIZER AND RETURN SIDE DUCT SMOKEDETECTORS ON ALL HVAC EQUIPMENT OVER 2000 CFM.H.PROVIDE EXHAUST AIR ENERGY RECOVERY ON ALL HVACEQUIPMENT OVER 5000 CFM SUPPY.I.SEE SCHEDULES, SPECIFICATIONS, DETAILS AND NOTES WHICHMAY SUPERCEDE THESE MINIMUM PERFORMANCE REQUIREMENTS.TAP AND FLEX DUCT SIZING TABLETAP AND FLEX DUCT SIZE SUPPLY DIFFUSER CFM RANGE RETURN/EXHAUST REGISTER CFM RANGE6"Ø FLEX / DUCT 1 CFM THRU 100 CFM 1 CFM THRU 80 CFM8"Ø FLEX / DUCT 105 CFM THRU 200 CFM 85 CFM THRU 175 CFM10"Ø FLEX / DUCT 205 CFM THRU 400 CFM 180 CFM THRU 300 CFM12"Ø FLEX / DUCT 405 CFM THRU 600 CFM 305 CFM THRU 525 CFMNOTES: 1. PROVIDE A VOLUME DAMPER ON SUPPLY, RETURN, EXHAUST AND OUTSIDE AIR TAPS,BALANCE TO DIFFUSER/REGISTER TAG VOLUME.14"Ø FLEX / DUCT 605 CFM THRU 900 CFM 530 CFM THRU 800 CFMPIPE SIZING SCHEDULESIZEMIN GPM MAX GPM3/4"03.51" 3.6 7.51 1/4" 7.6131 1/2"13.5202"21402 1/2"41753"761204"1212505"2514506"451750NOTES: 1. PIPE SIZING TABLE SHALL BE UTILIZED IF PIPE TAG IS NOT PRESENT.REQUIRED 2020 IECC ENERGY CONSERVATION COMPLIANCECODE SECTIONCOMPLIANCEC303.3 OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO OWNER BY CONTRACTOR FOR ALL EQUIPMENTC401.2 BUILDING COMPLIES WITH THE APPLICABLE SECTIONS OF CODE BASED ON METHOD 2C402.5 REFERENCE ARCHITECTURAL PLANS FOR AIR LEAKAGE CRITERIA C403.2.1HVAC LOAD SIZING HAS BEEN PERFORMED IN THE CARRIER HAP PROGRAM, USING RTS (HEAT BALANCE) METHODOLOGYC403.2.3 ALL HVAC EQUIPMENT MEETS OR EXCEEDS MINIMUM EFFICIENCIES, REFERENCE MECHANICAL DOCUMENTSC403.2.4 REQUIRED HVAC CONTROLS SHALL BE PROVIDED, REFERENCE MECHANICAL DOCUMENTSC403.2.4.3MOTORIZED DAMPERS PROVIDED FOR EXHAUST AND OUTSIDE AIR INTAKES GREATER THAN 300 CFM OR IN BUILDINGS 3 STORIES OR LESSC403.2.9.1 DUCT IS REQUIRED TO BE INSULATED TO THE INDICATED MINIMUM LEVEL, REFERENCE MECHANICAL DOCUMENTSC403.2.9.3 INSTALLING CONTRACTOR SHALL ENSURE THAT ALL AIR DISTRIBUTION COMPONENTS ARE PROPERLY SEALEDC403.2.9.5 DUCT SIZING AND DUCT DESIGN HAS BEEN PERFORMED, REFERENCE MECHANICAL DOCUMENTSC403.2.10 ALL PIPING INSULATION CRITERIA HAS BEEN MET, REFERENCE MECHANICAL / PLUMBING DOCUMENTSC403.2.11 MECHANICAL SYSTEMS SHALL BE COMMISSIONED AS REQUIREDC404.2 ALL WATER HEATING EQUIPMENT MEETS OR EXCEEDS MINIMUM EFFICIENCIES, REFERENCE PLUMBING DOCUMENTSC404.4 ALL DOMESTIC HOT WATER PIPING INSULATION CRITERIA HAS BEEN MET, REFERENCE PLUMBING DOCUMENTSC405.2 LIGHTING CONTROL CRITERIA HAS BEEN MET, REFERENCE ELECTRICAL DOCUMENTSC405.5 EXTERIOR LIGHTING TOTAL POWER DOES NOT EXCEED THE ALLOWANCE, REFERENCE ELECTRICAL DOCUMENTSC405.6 ELECTRICAL POWER HAS BEEN PROVIDED PER THE CODE REQUIREMENTS, REFERENCE ELECTRICAL DOCUMENTSC408.2.2 INSTALLING CONTRACTOR SHALL TEST AND BALANCE ALL HVAC SYSTEMS AND PROVIDE REPORT TO ENGINEERMECHANICAL DESIGN CONFORMS TO 2020 IECC AND IMC CODE REQUIREMENTSC103.2.1REFERENCE ARCHITECTURAL PLANS FOR FENESTRATION U-FACTORS AND SOLAR HEAT GAIN COEFFICIENTSREFERENCE ARCHITECTURAL PLANS FOR AREA-WEIGHTED U-FACTORS AND SOLAR HEAT GAIN COEFFICIENTSC103.2.2C103.2.3C103.2.4C103.2.5C103.2.6C103.2.7C103.2.8C103.2.9C103.2.10C103.2.11C103.2.12REFERENCE MECHANICAL AND PLUMBING DOCUMENTS FOR DUCT AND PIPE INSULATION MATERIALS, ARCHITECTURAL DOCUMENTS FOR ALL OTHER INSULATION MATERIALSREFERENCE MECHANICAL AND PLUMBING DOCUMENTS FOR EQUIPMENT TYPES, SIZES AND EFFICIENCIESREFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENT TYPES, SIZES AND EFFICIENCIESREFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENTAMD SYSTEM CONTROLSREFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENT HORSEPOWER AND CONTROLSREFERENCE MECHANICAL AND PLUMBING SPECIFICATIONS FOR SEALING AND INSULATION LOCATIONSREFERENCE ELECTRICAL DOCUMENTS FOR LIGHTING FIXTURE SCHEDULE AND CONTROLSREFERENCE ELECTRICAL DRAWINGS FOR DAYLIGHTING ZONESREFERENCE MECHANICAL SPECIFICATIONS FOR AIR SEALING DETAILSJ.FOR SMOKE DAMPERS, MC SHALL INSTALL DUCT SMOKE DETECTORS FURNISHED BY OTHERS.RAD FIN TUBE RADIATIONFURNACEFURENERGY RECOVERY VENTILATORERVCCOIL CONDENSATE DRAINREF REFRIGERANT PIPINGCRDCEILING RADIATION DAMPERTO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGMENT, THE PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE INTERNATIONAL ENERGY CODE, AS ADOPTED BY THE STATE.ENERGY CONSERVATION CODE COMPLIANCE STATEMENTSYMBOLDESCRIPTIONPIPING SYMBOLS CONT.803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:02:11 PMM001LEGEND &ABBREVIATIONS02/05/20212018089JCC, CTLCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNOTES:THE PROJECT IS DESIGNED UNDER THE 2020 NYS STRETCH CODES, 2020 NYS IECC, ASHRAE 90.1-2006, ITHACA GREEN BUILDING POLICY INITIATIVE,WELL BUILDING DESIGN CRITERIA VERSION 2, LEED VERSION 4.1, BASE TAX ABATEMENT AND ENHANCED ENERGY ABATEMENT AS WELL AS THE 2018 FGI REQUIREMENTS FOR OUTPATIENT FACILITIES.INCLUSIVE OF THE PROGRAMS LISTED ABOVE, LEED AND WELL BUILDING CREDITS ARE BEING PURSUED THAT SPECIFICALLY IMPACT THE MECHANICAL SCOPE. PIPING, SEALANT AND INSULATION MATERIAL, EQUIPMENT EFFICIENCIES, SPACE PRESSURIZATION REQUIREMENTS, INDOOR AIR QUAILITY REQUIREMENTS, ENERGY STAR EQUIPMENT, ETC. CONTRACTOR TO REVIEW ALL REQUIREMENTS PRIOR TO BID, ALL EQUIPMENT AND MATERIALS TO MEET OR EXCEED THE REQUIREMENTS OF THE PROGRAMS LISTED.THIS PROJECT WILL BE COMMISSIONED. REFERENCE SPECIFICATION SECTIONS 230800 AND 019113 FOR COMMISSIONING REQUIREMENTS.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021