HomeMy WebLinkAboutFP101 First Floor PlanREF.12345ABCE3.8F3.9WASTEHOLDING136STAFFBREAK133SOILED132CLEANSUPPLY134REGISTRATION124PUBLICTOILET100AEVS109EXAM121EXAM120SOILEDWORK111EXAM112EXAM115EXAM114PoSPATIENTTOILET105CCLEANLINENHOLDING137TRIAGE/INTERVIEW106STAFFTOILET103EXAM116STORAGE144WATERSERVICE146SUPPLYCHAINAREA138EVSSUPPLY&EQUIPMENT139EXAM118MAINELECTRICAL142EMERGENCYEQUIPMENTROOM141MAINSERVER140VESTIBULE100V2VESTIBULE100V1STAIR2ST2-1CORRIDOR122VITALSALCOVE105ACIRCULATION105SUB-WAITING105BCIRCULATION105CIRCULATION10588544569107CORRIDOR135WAITING/CIRCULATION123BLOODDRAW130BLOODDRAW129BLOODDRAW(PoS)128LABORATORY126SPECIMENTOILET127STAFFTOILET131CORRIDOR143BUILDINGMAINTENANCETOILET/SHOWER138ATREATMENT117CORRIDOR143RADIOLOGY(X-RAY)119STATLAB/MED110EXAM113MAINLOBBY100EVS125CLEANHOLDING107HOLDING/MAIL100CSTAFFBREAK102SHAREDPROVIDEROFFICE104111312FPFPFP123FPFP888MECHANICAL145WAITING/CIRCULATION123WAITING/CIRCULATION123CIRCULATION105RECEPTION101BVISITORTOILET101ALOBBY/WAITING101MAINLOBBY100803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:00:44 PMFP101FIRST FLOORPLAN02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNDRAWING NOTES:12PROVIDE UPRIGHT SPRINKLER HEAD UNDER LOWEST LANDING OF STAIRWELL.PROVIDE HEAD AT BOTTOM OF ELEVATOR SHAFT PER NFPA.34SPRINKLER CONTROL VALVE ASSEMBLY. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE AND EXPRESS DRAIN UP. REFER TO DETAIL DRAWING(S).5SPRINKLER STANDPIPE WITH HOSE STATION IN STAIRWELL. REFER TO DETAIL DRAWING(S).678FIRE SERVICE. REFER TO DETAIL DRAWING(S).FIRE DEPARTMENT CONNECTION (FDC). REFER TO DETAIL DRAWING(S). SLEEVE AND SEAL THROUGH WALL.9PROVIDE DRY SPRINLKER HEAD.TERMINATE 8" INDIRECT WASTE AT BLDG'S EXTERIOR 12" ABOVE FINISHED GRADE WITH TURNED DOWN ELBOW, 12x12 SPLASH BLOCK, BUG SCREEN AND FLAPPER VALVE. SLEEVE AND SEAL THROUGH WALL.GENERAL NOTES:A. COORDINATE ALL SPRINKLER MAINS, BRANCHES AND HEAD LOCATIONS WITH ALL OTHER TRADES.B. THE FIRE PROTECTION CONTRACTOR SHALL HYDRAULICALLY CALCULATE ALL SPRINKLER SYSTEMS AND SHALL SIZE THE PIPING ACCORDINGLY.C. PROVIDE FULL SPRINKLER COVERAGE FOR ALL CONCEALED SPACES PER NFPA 13.D. PROVIDE SPRINKLER HEAD UNDER ALL FIXED OBSTRUCTIONS WIDER THAN 4'-0" PER NFPA.E. FIRE PROTECTION CONTRACTOR TO COORDINATE COLOR(S) OF ALL CONCEALED SPRINKLER HEAD(S) WITH OWNER/ARCHITECT PRIOR TO ORDERING.F. PROVIDE DRY SPRINKLER HEADS(S) IN LOCATION WHERE TEMPERATURE CAN DROP BELOW 40 DEGREES UNLESS OTHERWISE NOTED.G. WHERE MAXIMUM CEILING TEMPERATURES CAN EXCEED 100 DEGREES PROVIDE SPRINKLER HEAD(S) WITH TEMPERATURE RATINGS PER NFPA 13.H. PROVIDE SPRINKLER HEADS IN ALL CLOSETS AND BATHROOMS (REGARDLESS OF SIZE) PER NFPA 13.I. PROVIDE STANDPIPE HOSE VALVES AT 4'-0" AFF ON INTERMEDIATE FLOORS. PROVIDE PRESSURE RESTRICTING HOSE VALVE ON ALL FLOORS WHERE STATIC SYSTEM PRESSURE EXCEEDS 100 PSI.J. COORDINATE SPRINKLER PIPING LOCATIONS WITH HEAT PUMPS. NO SPRINKLER PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.K. COORDINATE SPRINKLER PIPING LOCATIONS WITH DIFFUSERS AND REGISTERS. NO SPRINKLER PIPING SHALL BE RUN THRU LINEAR PLENUM BOXES. 3WATER SERVICE ROOM 3D VIEW10SLEEVE AND SEAL.11OPEN TO ABOVE.12WET FIRE PROTECTION LINE TO FEED FIRST FLOOR SPRINKLERS.13TO FIRE DEPARTMENT CONNECTION (FDC).3/16" = 1'-0"1FIRST FLOOR PLANREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021