HomeMy WebLinkAbout!Binder1_Fire ProtectionGENERAL NOTES:1. THE FIRE PROTECTION SYSTEM DESIGN, INSTALLATION AND MATERIALSSHALL CONFORM TO THE FIRE CODE AND AUTHORITIES HAVINGJURISDICTION. IN CASE OF CONFLICTS WITH CODES, DRAWINGS, ORSPECIFICATIONS, THE MOST STRINGENT SHALL PREVAIL.2. BEFORE COMMENCEMENT OF WORK, THE CONTRACTOR SHALL VERIFYTHE EXACT LOCATIONS, ELEVATIONS AND CHARACTERISTICS OF ALLUTILITIES AND PIPING, AND SHALL IMMEDIATELY NOTIFY THE ARCHITECTOF ANY DISCREPANCIES.3. THE DRAWINGS WERE PREPARED WITH THE BEST STRUCTURAL ANDARCHITECTURAL INFORMATION AVAILABLE. IT IS UNDERSTOOD THATEQUIPMENT LOCATIONS AND ROUTING OF PIPING MAY VARY FROM THATSHOWN ON THE PLANS AS CONSTRUCTION PROCEEDS.4. THESE DRAWINGS DO NOT INCLUDE ALL NECESSARY SAFETYREQUIREMENTS. CONTRACTOR TO COMPLY TO THE SAFETYREQUIREMENTS SET FORTH BY THE LOCAL AUTHORITIES HAVINGJURISDICTION.5. THESE DRAWINGS ARE FOR BIDDING PURPOSES ONLY. THEY AREESSENTIALLY DIAGRAMMATIC TO THE EXTENT THAT MANY OFFSETS,BENDS, UNIONS, SPECIFIC FITTINGS AND EXACT LOCATIONS ARE NOTINDICATED.6. ALL FIRE PROTECTION WORK SHALL BE INSTALLED SO AS TO AVOIDINTERFERENCE WITH ELECTRICAL EQUIPMENT, MECHANICALEQUIPMENTAND STRUCTURAL FRAMING, SKYLIGHTS, ETC.7. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILINGACCESS PANELS WITH THE ARCHITECTURAL REFLECTED CEILING PLANAND ELECTRICAL LIGHTING PLAN.8. COORDINATE ALL LOCATIONS, SIZES AND ELEVATIONS OF ALL SLEEVESTHROUGH WALLS, BEAMS, SLABS AND FOOTING WITH STRUCTURAL ANDARCHITECTURAL DRAWINGS. ALL PIPES SLEEVING THROUGH BEAMS ORFOOTINGS SHALL HAVE A SLEEVE DIAMETER OF TWO PIPE SIZES OVERTHE PIPE PASSING THROUGH THE FOOTING OR PER STRUCTURALDRAWING. THE MOST STRINGENT SHALL PREVAIL.9. PIPING SUPPORTS. ALL PIPING TO BE SUPPORTED WITH HANGERS ANDBRACKETS WHICH PROVIDE ISOLATION FROM FRAMING. CONTACTBETWEEN PIPE AND SUPPORT TO BE LINED WITH PLASTIC OR FELT.10.ALL FLOOR AND WALL PENETRATIONS MUST BE SEALED WATERTIGHTAND VERMIN PROOF.11.FIRE PROTECTION CONTRACTOR SHALL COORDINATE COMPLETE FIREPROTECTION INSTALLATION AND REQUIREMENTS PRIOR TO SUBMITTINGBID WITH ALL LOCAL DISTRICTS AND GOVERNING AUTHORITIES. INCLUDEALL FINDINGS WITHIN THE BASE BID.12.PROVIDE ALL WORK IN COMPLIANCE WITH ALL LOCAL, STATE ANDFEDERAL CODES. OBTAIN ALL REQUIRED PERMITS. COORDINATE ALLWORK WITH LOCAL FIRE MARSHAL.13. PROVIDE CUTTING, CORING AND PATCHING OF ALL WALLS, SLABS ANDDECKS AS REQUIRED FOR WORK SHOWN. COORDINATE ALL WORK WITHOWNER AND GENERAL CONTRACTOR.14. REFER TO ARCHITECTURAL DRAWINGS AND THE PROJECTSPECIFICATIONS FOR PROJECT PHASING REQUIREMENTS.15.PROVIDE FULL SPRINKLER COVERAGE FOR ALL SPACES WITHIN THEPROJECT AREA IN COMPLIANCE WITH LOCAL, STATE AND FEDERALCODES, NFPA-13 AND OWNER'S INSURANCE CARRIER/UNDERWRITER.16.PROVIDE FULL SPRINKLER COVERAGE FOR ALL SPACES WITHIN THEPROJECT AREA IN COMPLIANCE WITH LOCAL, STATE AND FEDERALCODES, NFPA-13 AND OWNER'S INSURANCE CARRIER/UNDERWRITER.17. PROVIDE SPRINKLER SHOP DRAWINGS AND HYDRAULIC CALCULATIONSWITH ALL INFORMATION NOTED BY NFPA-13. DO NOT START ANY WORKUNTIL DRAWINGS AND CALCULATIONS HAVE BEEN APPROVED BY THEPROJECT ENGINEER, OWNER'S AGENTS AND LOCAL FIRE MARSHAL.18.OBTAIN WATER FLOW TEST DATA (PRESSURES AND FLOWS) ASREQUIRED. PROVIDE ALL FLOW TESTS REQUIRED IF CURRENT TESTDATA IS UNAVAILABLE.19.COORDINATE SPRINKLER SYSTEM WITH ALL OTHER TRADES, BUILDINGCONDITIONS, ETC. OFFSET SPRINKLER SYSTEM PIPING AS REQUIRED(PROVIDE ALL FITTINGS, CONNECTIONS, ETC.)20.FOR ALL AREAS WITH LAY-IN CEILINGS, PROVIDE SPRINKLERS IN THECENTER OF CEILING TILES (2x2 PATTERN). REFER TO ARCHITECTURALPLAN FOR CEILING GRID LAYOUT.21. THE SPRINKLER/FIRE PROTECTION CONTRACTOR SHALL HYDRAULICALLYCALCULATE ALL SPRINKLER SYSTEMS SHOWN ON THE DRAWING ANDSHALL SIZE PIPING ACCORDINGLY.22.SUBMITTALS AND SHOP DRAWINGS: AS SOON AS POSSIBLE AND WITHIN21 DAYS AFTER AWARD OF THE CONTRACT, AND BEFORE THEIRPURCHASE, THE CONTRACTOR SHALL SUBMIT TO THE ARCHITECT 6BOUND BOOKLETS FOR APPROVAL AND CONTAINING A COMPLETE LISTOF MATERIALS, SPECIALTIES AND EQUIPMENT HE IS TO FURNISH FORTHE INSTALLATION. ALL SUBMITTALS SHALL BE MADE AT ONE TIME. NODEVIATION OF PLUMBING FIXTURES WILL BE ACCEPTED. BASED ONAPPROVAL OF ALTERNATE PRIOR TO BID.23. COORDINATE FIRE PROTECTION SYSTEMS WITH WORK OF ALL OTHERTRADES PRIOR TO ANY FABRICATION OR INSTALLATION.24.ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THEEQUIPMENT MANUFACTURER'S RECOMMENDATIONS AND APPLICABLECODES, PROVIDE ALL FITTINGS, VALVES, AND OTHER DEVICES REQUIREDFOR A COMPLETE WORKABLE INSTALLATION.25. MAINTENANCE LABEL SHALL BE AFFIXED TO ALL FIRE PROTECTIONEQUIPMENT AND A MAINTENANCE MANUAL SHALL BE PROVIDED TOOWNER'S REPRESENTATIVE.26.FIRE PROTECTION CONTRACTOR SHALL LAYOUT SPRINKLER SYSTEM.COORDINATE WITH ALL OTHER TRADES, AND SHALL PROVIDE SPRINKLERSHOP DRAWINGS AND HYDRAULIC CALCULATIONS. SPRINKLER PIPINGSHALL BE SIZED HYDRAULICALLY.27. SPRINKLERS SHALL BE INSTALLED UNDER FIXED OBSTRUCTIONS OVER 4FEET WIDE SUCH AS DUCTS, OPEN GRATE FLOORING AND OVERHEADDOORS.28. COORDINATE WITH ELECTRICAL TRADE PRIOR TO ORDERINGELECTRICALLY OPERATED EQUIPMENT FOR AVAILABLE VOLTAGES ATEQUIPMENT LOCATIONS.29.PIPE SIZE DISCREPANCIES BETWEEN FLOOR PLANS AND RISERDIAGRAMS LARGER PIPE SIZE INDICATED WILL TAKE PRECEDENCE.30.THESE PLANS INDICATE APPROXIMATE ROUGH-INS ONLY FOREQUIPMENT NOT IN THIS SECTION (N.I.T.S.) EXACT ROUGH-INDIMENSIONS MUST BE OBTAINED FROM THE EQUIPMENTMANUFACTURER.31. THE FIRE PROTECTION CONTRACTOR SHALL COORDINATE ALLREQUIREMENTS FOR ALL POINTS OF CONNECTION WITH THE GENERALCONTRACTOR AND OTHER TRADES PRIOR TO BID.32.FIRE PROTECTION CONTRACTOR SHALL LAYOUT SPRINKLER SYSTEM,COORDINATE WITH ALL OTHER TRADES, AND SHALL PROVIDE SPRINKLERSHOP DRAWINGS AND HYDRAULIC CALCULATIONS. SPRINKLER PIPINGSHALL BE SIZED HYDRAULICALLY.33.CONTRACTOR SHALL PROVIDE ALL VALVES AND BACKFLOW PREVENTIONDEVICES AS REQUIRED BY STATE AND LOCAL CODES.34.SPRINKLER HEADS WITHIN ATTIC SPACE SHALL BE 212 F.35. PROVIDE CORROSIVE COATING ON SPRINKLER HEADS IN POOL.APPLICABLE CODES:THE INTERNATIONAL FIRE CODE.NFPA 13: STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS.NFPA 14: STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEMS.NFPA 25: RECOMMENDED PRACTICE FOR THE INSPECTION, TESTING ANDMAINTENANCE OF WATER-BASED FIRE PROTECTION SYSTEMS.SPRINKLER SYSTEM DESCRIPTION:THE FIRE PROTECTION SYSTEM SHALL BE A WETPIPE AUTOMATICSPRINKLER SYSTEM ARRANGED TO PROPERLY PROTECT ALL SPACESAS INDICATED.STANDPIPE SYSTEM DESCRIPTION:THE STANDPIPE SYSTEM SHALL BE A WET MANUAL CLASS I STANDPIPESYSTEM.FLOW TEST DATA:STATIC PRESSURE94PSIRESIDUAL PRESSURE62PSIFLOW1900GPMCLASSIFICATION OF OCCUPANCIES:1.LIGHT HAZARD:WATER DENSITY:0.10 GPM/SQ. FT.HYDRAULIC REMOTE AREA:1500 SQ. FT.COMBINED HOSE DEMAND:100 GPMWATER DENSITY:0.15 GPM/SQ. FT.HYDRAULIC REMOTE AREA:1500 SQ. FT.COMBINED HOSE DEMAND:250 GPM2. ORDINARY GROUP I:SYSTEM PROTECTION AREA LIMITATIONS:LIGHT HAZARD:52,000 SQ. FT.ORDINARY HAZARD: 52,000 SQ. FT.TSSYMBOLDESCRIPTIONSHUT OFF VALVE WITH TAMPER SWITCH (TS)FLOW SWITCH (FS)FIRE PROTECTION SYMBOLS LISTREMOVE TO THIS POINTNEW TO EXISTING CONNECTIONEXISTING PIPINGPIPING TO BE REMOVEDDROP CONNECTIONELBOW UPDIRECTION OF FLOWCAP OR PLUGCHECK VALVEPRESSURE GAGEBACKFLOW PREVENTERDRY PIPE VALVEALARM CHECK VALVESIDEWALL SPRINKLER HEADPENDENT SPRINKLER HEADSEMI-RECESSED SPRINKLER HEADUPRIGHT SPRINKLER HEADCONCEALED SPRINKLER HEADFIRE DEPARTMENT CONNECTION (FDC)PIPE CONTINUATION (SINGLE LINE)PIPE CONTINUATION (DOUBLE LINE)BREAKBUTTERFLY VALVEPUMPFIRE HYDRANTELBOW DOWNFSNOTE: NOT ALL SYMBOLS ARE NECESSARILY USED ON THIS PROJECTNEW PIPINGEXHIBIT "B" - PIPING MATERIALS (FIRE PROTECTION)(NOTES AT END OF EXHIBIT "B")SERVICEPIPE MATERIALFITTINGSCONNECTIONSSPRINKLER(WET)SCHEDULE 40, BLACK STEEL2" AND SMALLERMALLEABLEORDUCTILE IRONTHREADEDSCHEDULE 10, BLACK STEEL 2 1/2" AND LARGERMALLEABLEORDUCTILE IRONROLL GROOVED MECHANICAL TYPE COUPLINGSFIRE STANDPIPESCHEDULE 40, BLACK STEEL2-1/2" AND SMALLERMALLEABLE IRONTHREADEDSCHEDULE 10, BLACK STEEL3" AND LARGERMALLEABLEORDUCTILE IRONROLL GROOVED MECHANICAL TYPE RIGID COUPLINGSFIRE SERVICEDUCTILE IRONW/CEMENT LININGBELL & SPIGOTMECHANICAL OR GROOVED RUBBER GASKETUSE GALVANIZED STEEL PIPE AND FITTINGS FOR ALL ABOVEGROUND EXTERIOR LOCATIONS PASSING THROUGH EXTERIOR WALLS AND WHERE CALLED FOR.NOTES FOR EXHIBIT BNOTE 1:ALL EXPOSED PIPING WITHIN FINISHED AREAS SHALL BE PAINTED WITH A PRIMER COAT AND TWO FINISH COATS. COLOR PER THE ARCHITECT/OWNER.NOTE 2:803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:59:41 PMFP001LEGEND &GENERALNOTES02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021
REF.12345ABCE3.8F3.9WASTEHOLDING136STAFFBREAK133SOILED132CLEANSUPPLY134REGISTRATION124PUBLICTOILET100AEVS109EXAM121EXAM120SOILEDWORK111EXAM112EXAM115EXAM114PoSPATIENTTOILET105CCLEANLINENHOLDING137TRIAGE/INTERVIEW106STAFFTOILET103EXAM116STORAGE144WATERSERVICE146SUPPLYCHAINAREA138EVSSUPPLY&EQUIPMENT139EXAM118MAINELECTRICAL142EMERGENCYEQUIPMENTROOM141MAINSERVER140VESTIBULE100V2VESTIBULE100V1STAIR2ST2-1CORRIDOR122VITALSALCOVE105ACIRCULATION105SUB-WAITING105BCIRCULATION105CIRCULATION10588544569107CORRIDOR135WAITING/CIRCULATION123BLOODDRAW130BLOODDRAW129BLOODDRAW(PoS)128LABORATORY126SPECIMENTOILET127STAFFTOILET131CORRIDOR143BUILDINGMAINTENANCETOILET/SHOWER138ATREATMENT117CORRIDOR143RADIOLOGY(X-RAY)119STATLAB/MED110EXAM113MAINLOBBY100EVS125CLEANHOLDING107HOLDING/MAIL100CSTAFFBREAK102SHAREDPROVIDEROFFICE104111312FPFPFP123FPFP888MECHANICAL145WAITING/CIRCULATION123WAITING/CIRCULATION123CIRCULATION105RECEPTION101BVISITORTOILET101ALOBBY/WAITING101MAINLOBBY100803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:00:44 PMFP101FIRST FLOORPLAN02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNDRAWING NOTES:12PROVIDE UPRIGHT SPRINKLER HEAD UNDER LOWEST LANDING OF STAIRWELL.PROVIDE HEAD AT BOTTOM OF ELEVATOR SHAFT PER NFPA.34SPRINKLER CONTROL VALVE ASSEMBLY. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE AND EXPRESS DRAIN UP. REFER TO DETAIL DRAWING(S).5SPRINKLER STANDPIPE WITH HOSE STATION IN STAIRWELL. REFER TO DETAIL DRAWING(S).678FIRE SERVICE. REFER TO DETAIL DRAWING(S).FIRE DEPARTMENT CONNECTION (FDC). REFER TO DETAIL DRAWING(S). SLEEVE AND SEAL THROUGH WALL.9PROVIDE DRY SPRINLKER HEAD.TERMINATE 8" INDIRECT WASTE AT BLDG'S EXTERIOR 12" ABOVE FINISHED GRADE WITH TURNED DOWN ELBOW, 12x12 SPLASH BLOCK, BUG SCREEN AND FLAPPER VALVE. SLEEVE AND SEAL THROUGH WALL.GENERAL NOTES:A. COORDINATE ALL SPRINKLER MAINS, BRANCHES AND HEAD LOCATIONS WITH ALL OTHER TRADES.B. THE FIRE PROTECTION CONTRACTOR SHALL HYDRAULICALLY CALCULATE ALL SPRINKLER SYSTEMS AND SHALL SIZE THE PIPING ACCORDINGLY.C. PROVIDE FULL SPRINKLER COVERAGE FOR ALL CONCEALED SPACES PER NFPA 13.D. PROVIDE SPRINKLER HEAD UNDER ALL FIXED OBSTRUCTIONS WIDER THAN 4'-0" PER NFPA.E. FIRE PROTECTION CONTRACTOR TO COORDINATE COLOR(S) OF ALL CONCEALED SPRINKLER HEAD(S) WITH OWNER/ARCHITECT PRIOR TO ORDERING.F. PROVIDE DRY SPRINKLER HEADS(S) IN LOCATION WHERE TEMPERATURE CAN DROP BELOW 40 DEGREES UNLESS OTHERWISE NOTED.G. WHERE MAXIMUM CEILING TEMPERATURES CAN EXCEED 100 DEGREES PROVIDE SPRINKLER HEAD(S) WITH TEMPERATURE RATINGS PER NFPA 13.H. PROVIDE SPRINKLER HEADS IN ALL CLOSETS AND BATHROOMS (REGARDLESS OF SIZE) PER NFPA 13.I. PROVIDE STANDPIPE HOSE VALVES AT 4'-0" AFF ON INTERMEDIATE FLOORS. PROVIDE PRESSURE RESTRICTING HOSE VALVE ON ALL FLOORS WHERE STATIC SYSTEM PRESSURE EXCEEDS 100 PSI.J. COORDINATE SPRINKLER PIPING LOCATIONS WITH HEAT PUMPS. NO SPRINKLER PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.K. COORDINATE SPRINKLER PIPING LOCATIONS WITH DIFFUSERS AND REGISTERS. NO SPRINKLER PIPING SHALL BE RUN THRU LINEAR PLENUM BOXES. 3WATER SERVICE ROOM 3D VIEW10SLEEVE AND SEAL.11OPEN TO ABOVE.12WET FIRE PROTECTION LINE TO FEED FIRST FLOOR SPRINKLERS.13TO FIRE DEPARTMENT CONNECTION (FDC).3/16" = 1'-0"1FIRST FLOOR PLANREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021
12345ABCE3.8F3.9PUBLICTOILET200APUBLICTOILET200BSTAFFTOILET205EXAM210EXAM211EXAM212EXAM215EXAM216EXAM217EXAM(GYN)218SHAREDCLEANWORK/MEDPREP219EXAM(GYN)PoS220PATIENTTOILET222VISITORTOILET(PoS)224DENTALTREATMENTROOM225DENTALEQUIPMENTSTERILIZATION227SHAREDSOILEDHOLDING229SHAREDEQUIPMENTSTORAGE231EVS226VITALSALCOVE223STAIR2ST2-1CORRIDOR23212STAFFBREAK242MULTIPURPOSE/ACTIVITY235TELMED233EDUCATION/CONFERENCE234RESPITE/LACTATION239STAFFTOILET236STAFFBREAK242RESPITE/LACTATION240STAFFTOILET237RESPITE/MEDITATION241OFFICE238UnoccupiedUnoccupiedIT/ELEC243MAINLOBBY100WAITING201SHAREDRECEPTION/REGISTRATION202SHAREDCLERICALOFFICE203MULTIPURPOSE/CONSULT/TELEMED204SHAREDMULTIPURPOSE/CONSULT/TELEMED206SHAREDSTAFFBREAK208MANAGEROFFICE209PHYSICIANOFFICE/DICTATION213NURSE214CIRCULATION2283CIRCULATION207LAB221TRIAGENURSEALCOVE207AWALKINGTRACK200DENTALOFFICE230WALKINGTRACK200STAIR1ST1-2803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:01:05 PMFP102SECONDFLOOR PLAN02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNGENERAL NOTES:A. COORDINATE ALL SPRINKLER MAINS, BRANCHES AND HEAD LOCATIONS WITH ALL OTHER TRADES.B. THE FIRE PROTECTION CONTRACTOR SHALL HYDRAULICALLY CALCULATE ALL SPRINKLER SYSTEMS AND SHALL SIZE THE PIPING ACCORDINGLY.C. PROVIDE FULL SPRINKLER COVERAGE FOR ALL CONCEALED SPACES PER NFPA 13.D. PROVIDE SPRINKLER HEAD UNDER ALL FIXED OBSTRUCTIONS WIDER THAN 4'-0" PER NFPA.E. FIRE PROTECTION CONTRACTOR TO COORDINATE COLOR(S) OF ALL CONCEALED SPRINKLER HEAD(S) WITH OWNER/ARCHITECT PRIOR TO ORDERING.F. PROVIDE DRY SPRINKLER HEADS(S) IN LOCATION WHERE TEMPERATURE CAN DROP BELOW 40 DEGREES UNLESS OTHERWISE NOTED.G. WHERE MAXIMUM CEILING TEMPERATURES CAN EXCEED 100 DEGREES PROVIDE SPRINKLER HEAD(S) WITH TEMPERATURE RATINGS PER NFPA 13.H. PROVIDE SPRINKLER HEADS IN ALL CLOSETS AND BATHROOMS (REGARDLESS OF SIZE) PER NFPA 13.I. PROVIDE STANDPIPE HOSE VALVES AT 4'-0" AFF ON INTERMEDIATE FLOORS. PROVIDE PRESSURE RESTRICTING HOSE VALVE ON ALL FLOORS WHERE STATIC SYSTEM PRESSURE EXCEEDS 100 PSI.J. COORDINATE SPRINKLER PIPING LOCATIONS WITH HEAT PUMPS. NO SPRINKLER PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.K. COORDINATE SPRINKLER PIPING LOCATIONS WITH DIFFUSERS AND REGISTERS. NO SPRINKLER PIPING SHALL BE RUN THRU LINEAR PLENUM BOXES. 4PROVIDE DRY SPRINKLER HEAD.DRAWING NOTES:123SPRINKLER CONTROL VALVE ASSEMBLY. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE AND EXPRESS DRAIN UP. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE WITH HOSE STATION IN STAIRWELL. REFER TO DETAIL DRAWING(S).3/16" = 1'-0"1SECOND FLOOR PLANREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021
12345ABC3.8ELEC/DATA323123PROVIDEROFFICE339ANURSEWORK339EXAM/CONSULT328EXAM/CONSULT329CIRCULATION304EVS330TRIAGENURSE339BEXAM/CONSULT327EXAM/CONSULT328EXAM/CONSULT331PATIENTTOILET336SPECIALTYEXAM/TREATMENT/TELEMED335CIRCULATION304PATIENTTOILET335ALAB334LABDRAW332SPECIMENCOLLECTION333STAIR1ST1-3GUESTWAITING/CIRCULATION300PUBLICTOILET300APUBLICTOILET300BREGISTRATION301REGISTRATION301OFFICEMANAGER301APATIENTTOILET302PATIENTVITALSALCOVE310CENTRALSOILEDWORK311EXAM/CONSULT309EXAM/CONSULT308EXAM/CONSULT307STAFFTOILET305ASTAFFBREAKAREA305SPECIALTYEXAM/TREATMENT303EXAM/CONSULT306PROVIDEROFFICE317ANURSEWORKAREA317BCENTRALCLEANWORK312EXAM/CONSULT313EXAM/CONSULT314EXAM/CONSULT315EXAM/CONSULT316EXAM/CONSULT322EXAM/CONSULT321EXAM/CONSULT320EXAM/CONSULT319EXAM/CONSULT318NURSEWORKAREA317EPROVIDEROFFICE317FTRIAGENURSE324SPECIALTYEXAM/TREATMENT326PATIENTTOILET327PATIENTTOILET326ASTAFFTOILET325??CIRCULATION304STAFFCIRCULATION317CIRCULATION304GUESTWAITING/CIRCULATION300STAIR2ST2-14444444803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:01:24 PMFP103THIRD FLOORPLAN02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNGENERAL NOTES:A. COORDINATE ALL SPRINKLER MAINS, BRANCHES AND HEAD LOCATIONS WITH ALL OTHER TRADES.B. THE FIRE PROTECTION CONTRACTOR SHALL HYDRAULICALLY CALCULATE ALL SPRINKLER SYSTEMS AND SHALL SIZE THE PIPING ACCORDINGLY.C. PROVIDE FULL SPRINKLER COVERAGE FOR ALL CONCEALED SPACES PER NFPA 13.D. PROVIDE SPRINKLER HEAD UNDER ALL FIXED OBSTRUCTIONS WIDER THAN 4'-0" PER NFPA.E. FIRE PROTECTION CONTRACTOR TO COORDINATE COLOR(S) OF ALL CONCEALED SPRINKLER HEAD(S) WITH OWNER/ARCHITECT PRIOR TO ORDERING.F. PROVIDE DRY SPRINKLER HEADS(S) IN LOCATION WHERE TEMPERATURE CAN DROP BELOW 40 DEGREES UNLESS OTHERWISE NOTED.G. WHERE MAXIMUM CEILING TEMPERATURES CAN EXCEED 100 DEGREES PROVIDE SPRINKLER HEAD(S) WITH TEMPERATURE RATINGS PER NFPA 13.H. PROVIDE SPRINKLER HEADS IN ALL CLOSETS AND BATHROOMS (REGARDLESS OF SIZE) PER NFPA 13.I. PROVIDE STANDPIPE HOSE VALVES AT 4'-0" AFF ON INTERMEDIATE FLOORS. PROVIDE PRESSURE RESTRICTING HOSE VALVE ON ALL FLOORS WHERE STATIC SYSTEM PRESSURE EXCEEDS 100 PSI.J. COORDINATE SPRINKLER PIPING LOCATIONS WITH HEAT PUMPS. NO SPRINKLER PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.K. COORDINATE SPRINKLER PIPING LOCATIONS WITH DIFFUSERS AND REGISTERS. NO SPRINKLER PIPING SHALL BE RUN THRU LINEAR PLENUM BOXES. DRAWING NOTES:123SPRINKLER CONTROL VALVE ASSEMBLY. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE AND EXPRESS DRAIN UP. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE WITH HOSE STATION IN STAIRWELL. REFER TO DETAIL DRAWING(S).3/16" = 1'-0"1THIRD FLOOR PLAN4DRY SPRINKLER HEAD.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021
12345ABC3.8PATIENTTOILET444SHAREDCONFERENCE433PATIENTTOILET418BELEC/DATA430NURSE/TECHSTATION411PATIENTTOILET413MAMMOGRAPHY427STAFFTOILET414EQUIPMENTSTORAGE431APATIENTTOILET424APATIENTTOILET(PoS)423APATIENTTOILET415AHOLDINGBAY1412ACIRCULATION406PATIENTTOILET407BPUBLICTOILET400BPUBLICTOILET400ASTAFFTOILET445EVS439STAIR2ST2-1STAIR1ST1-312PROCEDUREROOM442PROCEDUREROOM441PROCEDUREROOM440RECEPTION436PROVIDEROFFICE436AWAITING434CIRCULATION435STAFFBREAK443CLEANWORKROOM&EQUIP.STORAGE437SOILEDWORKROOM438ELEVATORLOBBY&PUBLICCORRIDOR400WHEELCHAIRSTORAGE400CIMAGINGGUESTLOUNGE/WAITING401DEXASCAN432EQUIPMENTSTORAGE&FLEXSPACE421SOILEDWORKROOM420CLEANWORKROOM419GOWNING418AMEN'SSUB-WAIT418EVS417MULTIPURPOSE/CONSULT405STORAGE404PRACTICEMANAGER403REGISTRATION402GOWNING1407AWOMEN'SCIRCULATION407GOWNING2407CGOWNING3407DSTAIR3ST3-4DIAGNOSTICRADIOGRAPHY416ULTRASOUND(PoS)423MAMMOGRAPHY(STEREOTATICBIOPSY)431WOMEN'SCIRCULATION425ULTRASOUND424ULTRASOUND(GUIDEDBIOPSY)415HOLDINGBAY2412BCIRCULATION412READINGROOM426OFFICE/READING428IMAGINGIT/DATA429WOMEN'SCIRCULATION425MEN'SCIRCULATION422ELEVATORLOBBY&PUBLICCORRIDOR40034IMAGINGGUESTLOUNGE/WAITING40155555556803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:01:40 PMFP104FOURTHFLOOR PLAN02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNGENERAL NOTES:A. COORDINATE ALL SPRINKLER MAINS, BRANCHES AND HEAD LOCATIONS WITH ALL OTHER TRADES.B. THE FIRE PROTECTION CONTRACTOR SHALL HYDRAULICALLY CALCULATE ALL SPRINKLER SYSTEMS AND SHALL SIZE THE PIPING ACCORDINGLY.C. PROVIDE FULL SPRINKLER COVERAGE FOR ALL CONCEALED SPACES PER NFPA 13.D. PROVIDE SPRINKLER HEAD UNDER ALL FIXED OBSTRUCTIONS WIDER THAN 4'-0" PER NFPA.E. FIRE PROTECTION CONTRACTOR TO COORDINATE COLOR(S) OF ALL CONCEALED SPRINKLER HEAD(S) WITH OWNER/ARCHITECT PRIOR TO ORDERING.F. PROVIDE DRY SPRINKLER HEADS(S) IN LOCATION WHERE TEMPERATURE CAN DROP BELOW 40 DEGREES UNLESS OTHERWISE NOTED.G. WHERE MAXIMUM CEILING TEMPERATURES CAN EXCEED 100 DEGREES PROVIDE SPRINKLER HEAD(S) WITH TEMPERATURE RATINGS PER NFPA 13.H. PROVIDE SPRINKLER HEADS IN ALL CLOSETS AND BATHROOMS (REGARDLESS OF SIZE) PER NFPA 13.I. PROVIDE STANDPIPE HOSE VALVES AT 4'-0" AFF ON INTERMEDIATE FLOORS. PROVIDE PRESSURE RESTRICTING HOSE VALVE ON ALL FLOORS WHERE STATIC SYSTEM PRESSURE EXCEEDS 100 PSI.J. COORDINATE SPRINKLER PIPING LOCATIONS WITH HEAT PUMPS. NO SPRINKLER PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.K. COORDINATE SPRINKLER PIPING LOCATIONS WITH DIFFUSERS AND REGISTERS. NO SPRINKLER PIPING SHALL BE RUN THRU LINEAR PLENUM BOXES. DRAWING NOTES:123SPRINKLER CONTROL VALVE ASSEMBLY. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE AND EXPRESS DRAIN UP. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE WITH HOSE STATION IN STAIRWELL. REFER TO DETAIL DRAWING(S).3/16" = 1'-0"1FOURTH FLOOR PLANPROVIDE SPRINKLER HEAD UNDER LANDING OF STAIRWELL.45DRY SPRINKLER HEAD.6OPEN TO ABOVE.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021
12345ABC3.8EXAM/CONSULT521EXAM/CONSULT507PROVIDEROFFICE539ANURSEWORK539EXAM/CONSULT528EXAM/CONSULT529EXAM/CONSULT531PATIENTTOILET527EXAM/CONSULT537TRIAGENURSE539BPATIENTTOILET536SPECIALTYEXAM/TREATMENT/TELEMED535PATIENTTOILET535ALAB534LABDRAW532SPECIMENCOLLECTION533ELEVATORCONTROLROOM500ELEVA500EAPUBLICTOILET501APUBLICTOILET501BOFFICEMANAGER502APATIENTTOILET503STAFFTOILET505ASTAFFBREAKAREA505STAIRVESTIBULE504ASPECIALTYEXAM/TREATMENT506EXAM/CONSULT508EXAM/CONSULT509NURSEWORKAREA517BPROVIDEROFFICE517ASTAFFCIRCULATION517EXAM/CONSULT516EXAM/CONSULT515EXAM/CONSULT514EXAM/CONSULT513CIRCULATION504BBEXAM/CONSULT522EXAM/CONSULT520EXAM/CONSULT519EXAM/CONSULT518SPECIALTYEXAM/TREATMENT526PATIENTTOILET526ASTAFFTOILET525TRIAGENURSE524IT/ELEC523PROVIDEROFFICE517FNURSEWORKAREA517E12STAIR1ST1-3CENTRALSOILEDWORK511PATIENTVITALSALCOVE510STAIRST2-244CIRCULATION517DSTAIR3ST3-5STAFFCIRCULATION517CIRCULATION504REGISTRATION502GUESTWAITING/CIRCULATION50135CIRCULATION504CIRCULATION504REGISTRATION502EVS530EXAM/CONSULT5385555555803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:02:01 PMFP105FIFTH FLOORPLAN02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGNGENERAL NOTES:A. COORDINATE ALL SPRINKLER MAINS, BRANCHES AND HEAD LOCATIONS WITH ALL OTHER TRADES.B. THE FIRE PROTECTION CONTRACTOR SHALL HYDRAULICALLY CALCULATE ALL SPRINKLER SYSTEMS AND SHALL SIZE THE PIPING ACCORDINGLY.C. PROVIDE FULL SPRINKLER COVERAGE FOR ALL CONCEALED SPACES PER NFPA 13.D. PROVIDE SPRINKLER HEAD UNDER ALL FIXED OBSTRUCTIONS WIDER THAN 4'-0" PER NFPA.E. FIRE PROTECTION CONTRACTOR TO COORDINATE COLOR(S) OF ALL CONCEALED SPRINKLER HEAD(S) WITH OWNER/ARCHITECT PRIOR TO ORDERING.F. PROVIDE DRY SPRINKLER HEADS(S) IN LOCATION WHERE TEMPERATURE CAN DROP BELOW 40 DEGREES UNLESS OTHERWISE NOTED.G. WHERE MAXIMUM CEILING TEMPERATURES CAN EXCEED 100 DEGREES PROVIDE SPRINKLER HEAD(S) WITH TEMPERATURE RATINGS PER NFPA 13.H. PROVIDE SPRINKLER HEADS IN ALL CLOSETS AND BATHROOMS (REGARDLESS OF SIZE) PER NFPA 13.I. PROVIDE STANDPIPE HOSE VALVES AT 4'-0" AFF ON INTERMEDIATE FLOORS. PROVIDE PRESSURE RESTRICTING HOSE VALVE ON ALL FLOORS WHERE STATIC SYSTEM PRESSURE EXCEEDS 100 PSI.J. COORDINATE SPRINKLER PIPING LOCATIONS WITH HEAT PUMPS. NO SPRINKLER PIPING SHALL BE RUN BELOW A HEAT PUMP TO ALLOW FOR DROPPING OF THE UNIT FOR SERVICE IF REQUIRED.K. COORDINATE SPRINKLER PIPING LOCATIONS WITH DIFFUSERS AND REGISTERS. NO SPRINKLER PIPING SHALL BE RUN THRU LINEAR PLENUM BOXES. 4PROVIDE UPRIGHT SPRINKLER HEAD AT THE TOP OF THE ELEVATOR SHAFT PER NFPA 13.DRAWING NOTES:123SPRINKLER CONTROL VALVE ASSEMBLY. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE AND EXPRESS DRAIN UP. REFER TO DETAIL DRAWING(S).SPRINKLER STANDPIPE WITH HOSE STATION IN STAIRWELL. REFER TO DETAIL DRAWING(S).3/16" = 1'-0"1FIFTH FLOOR PLAN5PROVIDE DRY SPRINKLER HEAD.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021
TSTSTSTSTSTSTSTSTO FEED 5TH FLOORSPRINKLERSTO FEED 4TH FLOORSPRINKLERSTO FEED 3TH FLOORSPRINKLERSTO FEED 2ND FLOORSPRINKLERS6" REDUCED PRESSURE DETECTORASSEMBLY MAKE: WATTS 957 RPDARUN DRAIN TO BUILDING'SEXTERIOR AND TERMINATE24" ABOVE GRADE WITH 45°GALVANIZED ELBOW TURNEDDOWNRISER VALVE FORFIRST FLOORTO FIRE DEPARTMENTCONNECTION (FDC)6" COMBINEDSERVICE2 1/2" HOSE VALVE AT 4'-0" AFF ONINTERMEDIATE FLOORS. PROVIDEPRESSURE RESTRICTING HOSE VALVEON ALL FLOORS WHERE STATIC SYSTEMPRESSURE EXCEEDS 100 PSI (TYPICAL)2 1/2" HOSE VALVE AT 4'-0" AFF ONINTERMEDIATE FLOORS. PROVIDEPRESSURE RESTRICTING HOSE VALVEON ALL FLOORS WHERE STATIC SYSTEMPRESSURE EXCEEDS 100 PSI (TYPICAL)2 1/2" HOSE VALVE AT 4'-0" AFF ONINTERMEDIATE FLOORS. PROVIDEPRESSURE RESTRICTING HOSE VALVEON ALL FLOORS WHERE STATIC SYSTEMPRESSURE EXCEEDS 100 PSI (TYPICAL)FIRST FLOORSECOND FLOORTHIRD FLOORFOURTH FLOORROOFFIFTH FLOORFSFSFSTSFSTS803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:02:04 PMFP301RISERDIAGRAM02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1FIRE PROTECTION SCHEMATICGENERAL NOTES:A. COORDINATE ALL SPRINKLER MAINS, BRANCHES AND HEAD LOCATIONS WITH ALL OTHER TRADES.B. THE FIRE PROTECTION CONTRACTOR SHALL HYDRAULICALLY CALCULATE ALL SPRINKLER SYSTEMS AND SHALL SIZE THE PIPING ACCORDINGLY.C. PROVIDE FULL SPRINKLER COVERAGE FOR ALL CONCEALED SPACES PER NFPA 13.D. PROVIDE STANDPIPE HOSE VALVES AT 4'-0" AFF ON INTERMEDIATE FLOORS. PROVIDE PRESSURE RESTRICTING HOSE VALVE ON ALL FLOORS WHERE STATIC SYSTEM PRESSURE EXCEEDS 100 PSI.REVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021
1.WATER SERVICE NOTES:BACKFLOW PREVENTER(S) MUST BE A MINIMUM OF 30" ANDMAXIMUM OF 60" ABOVE THE FINISHED FLOOR.2.BACKFLOW PREVENTER(S) INSTALL ABOVE 60", MUST BEPROVIDED WITH AN OSHA APPROVED SCAFFOLD PLATFORM ONSITE FOR REQUIRED TESTING AND INSPECTION OF BACKFLOWDEVICE(S).3.BACKFLOW PREVENTER(S) CLEARANCES:- MINIMUM 36" CLEAR IN FRONT OF DEVICE(S)- MINIMUM 12" CLEAR BEHIND DEVICE(S)- MINIMUM 24" CLEAR ABOVE DEVICE(S)4.DOMESTIC METER HEIGHT LIMITS 18" MIN. - 40" MAX.5.THE BACKFLOW PREVENTER(S) ARE LOCATED IN AN ADEQUATELYHEATED AND LIGHTED AREA TO PREVENT FREEZING AND ALLOWFOR MAINTENANCE AND TESTING OF THE DEVICE(S).6.ALL MATERIAL BEFORE BACKFLOW PREVENTER(S) TO BE BRASS,COPPER OR CEMENT LINED DUCTILE IRON. VICTAULIC GROOVED/ROLLED PIPING AND FITTINGS ARE NOT ACCEPTABLE UPSTREAM OF THE BACKFLOW PREVENTER(S).7.AIR GAP FITTINGS ARE NOT ALLOWED.FINISHED FLOOR60"8"PIPE SUPPORT(TYPICAL)~BY FPC6" REDUCED PRESSURE DETECTOR ASSEMBLY MAKE: WATTS 957 RPDA. PROVIDE A 8x6 FUNNEL FITTING CENTERED UNDER BOTH RPDA AND THE 3/4" DETECTOR RELIEF VALVES. RPZ RELIEF GAP SHALL BE A MINIMUM OF TWO TIMES THE RPZ DISCHARGE OPENING6" OS&Y VALVE WITH TAMPER SWITCH (TYPICAL OF 3)SLEEVE &SEAL (TYPICAL)6" COMBINED WATER SERVICE TO FIRST FLOOR WET SYSTEMTO FIRE DEPARTMENTCONNECTION (FDC)FLOW SWITCH(TYPICAL)4" RISER VALVEW/TRIM (TYPICAL)1" BALL VALVE FOR INSPECTORS TEST CONNECTION, PIPE TOEXTERIOR (TYPICAL)CHECK VALVETO STANDPIPES6" OS&Y VALVE WITHTAMPER SWITCH6X4 TEE TO DOMESTICSERVICETERMINATE 8" DRAIN AT BUILDING'S EXTERIOR, 12"ABOVE GRADE WITH TURNED DOWN ELBOW, 12x12 SPLASH BLOCK, BUG SCREEN AND FLAPPER VALVEBDAOBSTRUCTIONCEILINGWALLA>(D-8")+ BD<30"PER NFPA 13SPRINKLERS SHALL BE POSITIONED AWAYFROM OBSTRUCTIONS IN ACCORDANCEWITH NFPA 13.NOTES:1.NOTE:1. SLEEVE AND FIRE CAULK ALL FLOOR PENETRATIONS.2. PROVIDE HOE CONNECTION ON INTERMEDIATE FLOORS.4" CONTROL VALVE WITHTAMPER SWITCH. PROVIDEPRESSURE REDUCING VALVEWHERE PRESSURE EXCEEDS175 PSI2 1/2" HOSE VALVE AT 4'-0" AFF ON INTERMEDIATE FLOORS. PROVIDE PRESSURE RESTRICTINGHOSE VALVE ON ALL FLOORS WHERESTATIC SYSTEM PRESSURE EXCEEDS100 PSISTANDPIPE AND DRAINRISERS SHALL BEEXTENDED UPWARD FOREACH STORY ANDSECURELY CAPPED AT THETOPRUN 2 1/2" SPRINKLER SYSTEM DRAINDOWN THROUGH ALL FLOORS BELOW TOGROUND FLOOR. RUN DRAIN TO BUILDING'SEXTERIOR AND TERMINATE 24" ABOVEGRADE WITH 45° GALVANIZED ELBOWTURNED DOWN1" UNION WITHRESTRICTING ORIFICE2 1/2" DRAIN RISERAUX. DRAIN VALVEINSPECTOR'S TEST VALVEFLOW SWITCHPRESSURE GAUGE4" FP TO SPRINKLERSYSTEM AS SHOWN ONFLOOR PLANS6" COMBINED(SPRINKLER ANDSTANDPIPE) RISERCHECK VALVETEMPORARYCONN. PLUGVALVE ENDWHEN NOT IN USE1" SIGHT GLASS1" VALVE NOTOVER 7'-0"ABOVE FINISHEDFLOORWET SYSTEMBRANCH LINE1" BALL VALVEDRY ORPREACTIONSYSTEMEXTERIOR BLDG. WALLRETURN BEND FORDRY OR PREACTIONSYSTEMSMOOTH BORE, CORROSIONRESISTANT OUTLET GIVING FLOWEQUIVALENT TO ONE SPRINKLER1" THICK 24"x24"CONC. SPLASHBLOCKCAULKING SEALANT1" 45° ELBOWGRADE/ROOFC PIPE24"LFINISHED GRADEEXTERIOR BLDG. WALLCAULK AROUNDWALL ESCUTCHEONFIRE DEPARTMENTCONNECTION GRAPHICSIGNFDC APPROX. 3'-0"ABOVE FINISHEDGRADE3/4" BALL DRIP VALVE W/3/4"COPPER DRAIN TO EXTERIOR ORFLOOR DRAINCAULK SEALANTFIRE PROTECTIONFEED MAINANCHORPIPE TOWALLCHECK VALVENOTE:VERIFY SIZE AND TYPE OF FIRE DEPARTMENT CONNECTION (FDC) WITH LOCAL FIRE MARSHALL.FIN. FLOOR2 1/2" FPFROM SYSTEM48"2 1/2" ANGLE VALVESTANDPIPE IN STAIRWELL803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 2:02:07 PMFP501DETAILS02/05/20212018089AuthorCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1FIRE SERVICE2SPRINKLER OBSTRUCTION DETAIL3STANDPIPE (COMBINED SYSTEM)4INSPECTOR TEST DETAIL6FIRE DEPARTMENT CONNECTION5FIRE HOSE CABINETREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021