HomeMy WebLinkAboutE504 DetailsFFFFFFFFSSHHFSDSDFSSHHSSHHFSDSDFSSHHSSFTSECSSHHFSDSDFSSHHSSHHFSDSDFSSHHSSFTSECSSHHFSDSDFSSHHSSHHFSDSDFSSHHSSFTSECFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFSSHHFSDSDFSSHHSSHHFSDSDFSSHHSSFTSECSSHHFSDSDFSSHHSSHHFSDSDFSSHHSFTSECSDSDNOTE:WIRING ON RISER DIAGRAM IS DIAGRAMMATIC ONLY AND ISNOT INTENDED TO INDICATE ROUTING OR QUANTITIES OFCABLES. PROVIDE WIRING FOR A COMPLETE AND WORKINGSYSTEM AS REQUIRED BY THE SYSTEM MANUFACTURER. ALLDEVICES MAY NOT BE INDICATED ON THE RISER DIAGRAM.REFER TO FLOOR PLANS FOR LOCATIONS AND EXACTQUANTITIES OF DEVICES.SDSDACACSDSDACACSDSDACACNOTES:NOTES:A.B.C.D.E.PROVIDE INITIATION DEVICE CIRCUITS AS REQUIRED TO CONNECTALL DEVICES.PROVIDE DUCT SMOKE DETECTORS AND FAN SHUTDOWN RELAYSAS CALLED FOR ON THE DRAWINGS.THIS DETAIL IS DIAGRAMMATIC ONLY: ALL QUANTITIES AND LOCATIONSOF DEVICES ARE SHOWN ON DRAWINGS.ALL SMOKE AND HEAT DETECTORS ARE CEILING MOUNTED UNLESSOTHERWISE NOTED.PROVIDE NOTIFICATION APPLIANCE CIRCUIT POWER EXTENDERPANELS AS REQUIRED. LOCATE IN FIELD TO OPTIMIZE NAC WIRING.PROVIDE 120 VOLT, 20A BRANCH CIRCUIT FROM NEAREST BRANCHCIRCUIT PANEL TO EACH PANEL.MAIN ENTRANCETWO TELEPHONE LINESTWO TELEPHONE LINES1ST FLOOR INITIATION DEVICE CIRCUITELEV.LOBBYSMOKEDAMPER(TYPICAL)2ND FLOOR INITIATION DEVICE CIRCUITELEV.LOBBYSMOKEDAMPER(TYPICAL)3RD FLOOR INITIATION DEVICE CIRCUITELEV.LOBBYSMOKEDAMPER(TYPICAL)FAN SHUTDOWN RELAYPRINTERDIGITALCOMMUNICATOR24 VDCFAN SHUTDOWN RELAY24 VDC120 VOLTCONNECTIONREMOTEANNUNCIATORDOOR HOLD OPEN CIRCUIT1ST FLOORNAC #1120VFACP(1ST FL)120V120V2ND FLOORNAC #13RD FLOORNAC #15TH FLOORNAC #14TH FLOORNAC #1SDSDACACAC5TH FLOOR INITIATION DEVICE CIRCUITELEV.LOBBYSMOKEDAMPER(TYPICAL)4TH FLOOR INITIATION DEVICE CIRCUITELEV.LOBBY120VMMSSSS SSHTCTCSHTO INITIATINGDEVICECIRCUIT (VIAZAM)THIS DRAWING IS DIAGRAMMATIC ONLY. FUNCTIONS SHOWN ASHARDWIRED MAY BE ACCOMPLISHED THROUGH THE USE OFINTELLIGENT DEVICES AND SOFTWARE.ALL RELAYS ARE SHOWN IN THE DE-ENERGIZED STATE.ELEVATORCAB LIGHTS,FANS ETC.1.2.NOTES:20A/1PINSTALL 208V AC, 30A DOUBLEPOLE, FUSIBLE, SINGLE THROW SWITCH (HUBBELL CATALOG NO 1392 OR APPROVED EQUIVALENT)SUPERVISINGRELAYR22ND FLOOR LOBBYSMOKE DETECTORAS NOTEDAS NOTEDaaINSTALL 208V AC FUSIBLE DISCONNECTSWITCH WITH AUXILARY CONTACTS. FUSESSIZED PER ELEVATOR MANUFACTURER'SRECOMMENDATIONSLOSSOF ACLOSSOF ACELEVATORCONTROLLER1ST FLOOR LOBBYSMOKE DETECTORRECALLRECALL3RD FLOOR LOBBYSMOKE DETECTORLOSS OF AC CONTACTS & SWITCHES ONLYREQUIRED IF ELEVATOR EQUIPED WITH BATTERYLOWERING.G.C. TO PROVIDE PROGRAMMING FOR ONLY (1) ELEVATOR TO OPERATE DURING GENERATOR USE. ATS CONNECTION TO ELEVATOR CONTROLLERS BY E.C.WIRING BY OTHERSWIRING BY E.C.1.OFF-TIME DELAY RELAYLEGEND:R1ELEVATOR SHAFT HEATDETECTORDESIGNER NOTES:ELEVATOR5TH FLOOR LOBBYSMOKE DETECTORELEVATOR SHAFTSMOKE DETECTORSH2.S4TH FLOOR LOBBYSMOKE DETECTORADDRESSABLE SMOKE DETECTOR WITH AIR DUCTHOUSING, INTAKE AND EXHAUST TUBING, AND REMOTEAUXILARY CONTACT.CLOSED POSITION INDICATORELECTRIC FUSE LINKOPEN POSITION INDICATORDAMPER ACTUATORTHIS DRAWING IS DIAGRAMMATICONLY. FUNCTIONS SHOWN ASHARDWIRED MAY BEACCOMPLISHED THROUGH THEUSE OF INTELLIGENT DEVICESAND SOFTWARE.NOTES:1.COMBINATION SMOKE/FIREDAMPER PACKAGE WITHELECTRIC ACTUATOR ANDSWITCH PACKAGE, FUNISHEDAND INSTALLED BY MECHANICALCONTRACTOR (TYP, 15 TOTAL)120VCIRCUIT20A/1P6#14 (2 SPARE),1/2"C (TYPTO EMS FOR DAMPER POSITIONBY CONTROLS CONTRACTORN6#14 (2 SPARE),1/2"C (TYPTO EMS FOR DAMPER POSITIONBY CONTROLS CONTRACTORBDA24VBATTERYBACKUP120V120VCONNECT TO FIRE ALARM PANEL5 SUPERVISORY MODULES REQUIRED:• BDA ANTENNA FAILURE• BDA TROUBLE• BDA POWER LOSS• BDA CHARGER TROUBLE• BDA LOW BATTERY(2) EMERGENCY CIRCUITSBDA STATUS ANNUNCIATOR.LOCATE ADJACENT TO FACP8-CONDUCTOR 18-24GA CABLELIGHTNING ARRESTOR, GROUNDED. LOCATED OUTSIDE, BEFORE THE CABLE BUILDING ENTRYANTENNA MAST TO BE BONDED TO BUILDING STEELDONOR ANTENNA.AIM TOWARDS PUBLIC SAFETY CITY REPEATERA2A3T1A11/2" PLENUM RATED COAXIAL CABLELEVEL 02LEVEL 03ROOFLEVEL 01GENERAL NOTES:1. PROVIDE A FULLY CODE COMPLIANT BI-DIRECTIONAL AMPLIFICATION SYSTEM AS REQUIRED PER IFC, IBC, NFPA AND ANY LOCAL CODES. CONFIRM WITH LOCAL AHJ TO DETERMINE REQUIRED FREQUENCIES AND VERIFY IF OTHER FIRST RESPONDER AGENCIES REQUIRE TWO-WAY RADIO ENHANCEMENTS. 2. A RADIO FREQUENCY SURVEY SHALL BE CONDUCTED TO DETERMINE THE SIGNAL STRENGTH WITHIN THE BUILDING. THE MINIMUM SIGNAL STRENGTH OF -95DBM SHALL BE MAINTAIN INTO AND OUT OF THE BUILDING TO DETERMINE COVERAGE AS REQUIRED PER IFC. 3. THE APPROPRIATE DONOR ANTENNA SHALL BE PROVIDED BASED ON REQUIRED FREQUENCY AND FACING IN THE DIRECTION OF THE CITY REPEATER. THE LOCATION OF THE ANTENNA SHALL BE COORDINATED WITH OTHER TRADES AND SHALL NOT INTERFERE WITH WORKING CLEARANCES OF EQUIPMENT OR PERSONNEL ACCESS WALKWAYS. 4. MAINTAIN ISOLATION BETWEEN THE DONOR ANTENNA AND DAS ANTENNAS WITHIN THE BUILDING. 5. A LIGHTNING ARRESTOR SHALL BE PROVIDED BY THE DONOR ANTENNA PRIOR TO ENTERING THE BUILDING. 6. THE BDA UNIT SHALL BE UNOBSTRUCTED BY OBJECTS IN FRONT OF THE UNIT. A BATTERY ENCLOSURE SHALL BE PROVIDED TO MAINTAIN A MINIMUM OF 24 HRS OF BATTERY BACKUP. 7. PROVIDE REQUIRED QUANTITY OF DAS ANTENNAS WITHIN THE BUILDING TO INSURE PROPER COVERAGE THROUGHOUT THE FLOOR. THE DAS ANTENNAS SHALL BE SUITED FOR THE REQUIRED FREQUENCY AND SHALL NOT EXCEED MANUFACTURES RECOMMENDED SPACING AND INSTALLATION. 8. ALL COAXIAL CABLING SHALL BE PLENUM RATED, COLOR CODED RED AND SHALL BE PROPERLY SECURED IN AN APPROPRIATE PATHWAY TO MAINTAIN PROPER BEND RADIUS AND PREVENT SAGGING OR KINKING. MAIN VERTICAL RUN OF COAXIAL CABLE SHALL BE IN A 2 HR RATED ENCLOSURE. THE RATING SHALL BE MAINTAINED IF THE MAIN RUN REQUIRES TO BE OFFSET WITHIN FLOORS. FINAL QUANTITY OF REQUIRED COAXIAL CABLE, SPLITTERS AND CONNECTORS SHALL BE DETERMINED BY FINAL DAS DESIGN AFTER CONDUCTING RF SURVEY. 9. PROVIDE A DEDICATED ANNUNCIATOR PANEL SEPARATE FROM THE FACP TO MONITOR THE STATUS OF THE BDA. FINAL LOCATION OF THE ANNUNCIATOR PANEL SHALL BE DETERMINED BY THE LOCAL AHJ. 10. THE BDA SHALL BE FULLY SUPERVISED BY THE FACP VIA ADDRESSABLE MONITORING MODULES TO IDENTIFIED THE FOLLOWING CONDITIONS; DONOR ANTENNA MALFUNCTION, BDA FAILURE, LOW BATTERY CAPACITY, LOSS OF NORMAL AC POWER AND FAILURE OF A BATTERY CHARGER.11. THE BDA SHALL SUPPORT FREQUENCIES OF 806-824 Mhz AND 769-799 Mhz PER THE CITY OF ITHACA. CONTACT LEE SHURTLEFF, DIRECTOR OF THE COUNTY DEPARTMENT OF EMERGENCY RESPONSE, FOR FURTHER REQUIREMENTS.LEVEL 04LEVEL 05806-824 MHz769-799 MHzAND803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:59:11 PME504DETAILS02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1FIRE ALARM RISER DIAGRAM2FIRE ALARM ELEVATOR CONTROL WIRING DIAGRAM3FIRE/SMOKE DAMPER WIRING DIAGRAM4BDA RISER DIAGRAMREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021