Loading...
HomeMy WebLinkAboutE001 Legend & AbbreviationsC/PHDBMSMVFDMMJPBCBSDDCCR A A AT AFATSMTSSSSSVMMICPAPACCBPSOHADHDHDHECTSFCZIAPSFSDAMMTTTSWBSWBSWBSWBTVTVTELSWBTSVCRDCKPSMDSSERMLICELRELPSIDCCY12:00WSHSDSSFWPACSCHEMATIC SYMBOLSHEALTH CAREMISCELLANEOUSPUBLIC ADDRESSSECURITYLIGHTINGPOWERONE LINE SYMBOLSNOTE:ABBREVIATIONS:POWER DISTRIBUTIONFIRE ALARM SYSTEMCOMMUNICATIONS11AaACAACVALMAVRAVSBACVBFMCCCCTCSCTDCADCVDMD(E)EECECSESPBERLETRFFTGALGENIACVIFMLTSMCMPUNOPCPTS1S2SCSSHTCSILSSSTBSYNCTSVARWREWTD- NORMALLY OPEN AUXILIARY CONTACT-AC AMMETER-AC VOLTMETER-ALARM- AUTOMATIC VOLTAGE REGULATOR- AMMETER / VOLTMETER PHASE SELECTOR SWITCH- BUS AC VOLTMETER- BUS FREQUENCY METER- INDICATING LIGHT C.B. CLOSED- CROSS COUPLED CURRENT TRANSFORMER- CIRCUIT BREAKER CONTROL SWITCH- CURRENT TRANSFORMER-DC AMMETER-DC VOLTMETER- DIGITAL METERING DISPLAY-EXISTING- EMERGENCY SOURCE- ELECTRICAL CONTRACTOR- ENGINE CONTROL SWITCH- EMERGENCY STOP PUSHBUTTON- EXISTING TO BE RELOCATED- EXISTING TO REMANI-FUSE-FLEXITEST SWITCHES- GENERATOR AVAILABLE LIGHT- GENERATOR- INCOMING AC VOLTMETER- INCOMING FREQUENCY METER- LAMP TEST PUSHBUTTON- MECHANICAL CONTRACTOR- MAGNETIC PICK-UP- NORMAL SOURCE- INDICATING LIGHT C.B. OPEN- PLUMBING CONTRACTOR- POTENTIAL TRANSFORMER-SOURCE 1-SOURCE 2- SYSTEM CONTROL SWITCH- SHUNT TRIP COIL- ALARM SILENCE PUSHBUTTON- SYNCHRONIZING SWITCH- SHORTING TERMINAL BOARD- SYNCHROSCOPE- TEMPERATURE SCANNER- VOLTAGE ADJUST RHEOSTAT- WARNING RESET PUSHBUTTON- WATT TRANSDUCER1. NOT ALL SYMBOLS, ABBREVIATIONS AND LINE DESIGNATIONS ARE NECESSARILY USED ON THIS PROJECT.HAND-OFF-AUTO SELECTORN.C. RELAY CONTACTN.O. RELAY CONTACTN.C. PUSHBUTTONN.O. PUSHBUTTONSOLONOID VALVE COILN.O. FLOW SWITCHN.C. FLOW SWITCHN.O. TEMPERATUREN.C. PRESSURE SWITCHN.O. PRESSURE SWITCHN.C. LEVEL SWITCHN.O. LEVEL SWITCHN.O. LOW LIMIT SWITCHEMERGENCY STOPN.C. HIGH LIMIT SWITCHN.O. HIGH LIMIT SWITCHN.C. LOW LIMIT SWITCHN.C. TEMPERATURE SWITCHINDICATOR LIGHTMAGNETIC DOOR CONTACTSPECIAL INTRUSION DETECTION SENSORCONNECT TO SECURITY SYSTEMHARDWARE OR DEVICE PROVIDED BY OTHERS.ELECTRO MAGNETIC LOCKINTRUSSION DETECTION CONTROL CENTERCLOSED CIRCUIT TELEVISION CAMERA (FIXED)CLOSED CIRCUIT TELEVISION CAMERA (PAN-TILT-ZOOM)ELECTRIC LATCH RETRACTION BARKEYPAD POWER SUPPLYELECTRIC LATCH RETRACTION BAR POWER SUPPLYDOUBLE FACESINGLE FACEBATTERYDOUBLE FACESENSORCEILING MOUNTEDDESCRIPTIONSTATIONSTATION (MAKE/MODEL JERON 7919)NURSE CALL MASTERNURSE CALL DOME LIGHT/ROOM CONTROLLER(MAKE/MODEL JERON 7953)NURSE CALL CODE EMERGENCYWALL MOUNTED EXIT SIGN,WALL MOUNTED COMBINATIONEXIT SIGN/EMERGENCYEGRESS LIGHTING, SINGLECEILING MOUNTED EXIT SIGN,LIGHTING CONTACTORCEILING MOUNTED EXIT SIGN,EMERGENCY LIGHTINGFIXTURE WITH INTEGRALEMERGENCY LIGHTINGFIXTURE WITH REMOTEBATTERY (TWO HEADS)EMERGENCY LIGHTINGFIXTURE WITH REMOTEBATTERY (SINGLE HEAD)WALL MOUNTED OCCUPANCYOCCUPANCY SENSORNOTEDESCRIPTIONREFERENCE TO DRAWINGSCHEDULEREFERENCE TO FEEDERROOM NUMBERARROWHEAD LINESYMBOLTERMINATORSYMBOLWIRE SIZE, WIRE COUNT,AND CONDUIT SIZE ASNOTEDWIRE MOLD/ PLUG MOLDDROP CORDPOWER POLECORD REELBREAKERRECEPTACLEPOWER CONNECTIONSINGLE FACE PEDESTALDOUBLE FACE PEDESTALEMERGENCY POWERBOXBOXJUNCTION BOXELECTRIC METERENCLOSED CIRCUITBUSPLUGPULLBOXFACESPEAKER CLUSTERVOLUME CONTROLPUBLIC ADDRESS EQUIPMENTPUBLIC ADDRESS CONTROLPUBLIC ADDRESS SPEAKERWALL MOUNTED MICROPHONEFLOOR MOUNTEDMICROPHONE OUTLETWALL MOUNTED CLOCKLETTER REFERS TOTYPE IN SPECIFICATIONSCLOCK SYSTEM BOOSTERPUBLIC ADDRESS INTERCOMPOWER SUPPLYI - IMPULSE TYPES - SYNCHRONOUS TYPEOUTLETSTATIONCENTERRACKELRPSKPPSINTERCOMELECTRIC LOCKPOWER SUPPLYINDICATES TYPE:A - AMMETERV - VOLTMETERMANUAL TRANSFER SWITCHMETER DESIGNATIONKWH - KILOWATT-HOURAMMETER SELECTORGROUND FAULTVOLTMETER SELECTORDRAW OUT DEVICEDESCRIPTIONDESIGNATION REFERS TOTYPE IN SPECIFICATIONWALL MOUNTED SPEAKER,TYPE IN SPECIFICATIONPROFESSIONAL QUALITYDESIGNATION REFERS TOCEILING MOUNTED SPEAKER,SPEAKERSYMBOLSWITCHSWITCHMETERMOTION DETECTOREXIT REQUESTKEYPADCARD READERDESCRIPTIONSYMBOLRELAY COILDESCRIPTION- OCCUPANCY SENSOR OPERATEDSWITCHINGDIMMER SWITCHPHOTO CONTROLDOWNLIGHTDOWNLIGHT4 FT. TRACK LIGHTDESIGNATION REFERS TOFIXTURE SCHEDULESINGLE POLE LIGHT SWITCHTHREE WAY LIGHT SWITCHFOUR WAY LIGHT SWITCHTIME CLOCK / SWITCHSINGLE POLE LIGHT SWITCHINDICATES MULTI-LEVELRECESSED FIXTURE,INDICATES FIXTURE ONEMERGENCY CIRCUITROUND RECESSED12" SQUARE RECESSEDWALL MOUNTED FIXTURE,DESIGNATION REFERS TOFIXTURE SCHEDULEWALL MOUNTED EXIT SIGN,ROUND WALL SCONCESTRIP FIXTURESQUARE WALL SCONCESPECIAL PURPOSE OUTLET,DRIVE, DESIGNATION REFERSMOTOR CONNECTION,DESIGNATION REFERS TOELECTRIC EQUIPMENTCONTROL SCHEDULE.VARIABLE FREQUENCYTO ELECTRIC EQUIPMENTCONTROL SCHEDULE.MANUAL MOTOR STARTER,INTERGRAL HORSEPOWER,PUSH BUTTON OPERATORELECTRIC EQUIPMENTCONTROL SCHEDULE.MANUAL MOTOR STARTER,FRACTIONAL HORSEPOWER,TOGGLE OPERATORCOMBINATION MAGNETICMOTOR STARTER/DISCONNECT SWITCH,DESIGNATION REFERS TOELECTRIC EQUIPMENTCONTROL SCHEDULE.BELL OR BUZZERFUSED DISCONNECT,DESIGNATION REFERS TOELECTRIC EQUIPMENTCONTROL SCHEDULE.NONFUSED DISCONNECT,DESIGNATION REFERS TOELECTRIC EQUIPMENTCONTROL SCHEDULE.MAGNETIC MOTOR STARTER,DESIGNATION REFERS TOPUSHBUTTONSUBSCRIPT REFERS TOELECTRIC HAND DRYERELECTRIC EQUIPMENTCONTROL SCHEDULEPOWER / COMMUNICATIONPOLESYMBOLWEATHERPROOFFLOOR BOXSURGE SUPPRESSIONABOVE COUNTERFLOOR RECEPTACLEBOX (QUAD)RECEPTACLEINTERRUPTERDUPLEX RECEPTACLETWO DUPLEX IN TWO GANGSPLIT WIRED DUPLEXGROUND FAULTDESCRIPTIONSYMBOLSOLID STATE BREAKERDESIGNATIONS INDICATECL - CURRENT LIMITINGL - LONG TIME TRIPS - SHORT TIME TRIPG - GROUND FAULT TRIPI - INSTANTANEOUS TRIPSHUNT TRIP TYPE CIRCUITFUSED DISCONNECT SWITCHBRANCH CIRCUITDISTRIBUTION PANEL,REFER TO PANELBOARDGROUND CONNECTIONAUTOMATIC TRANSFEREMERGENCY GENERATORSCHEMATIC MOTORLIGHTNING ARRESTORSWITCHSCHEDULESBREAKERFUSEFUNCTIONS:PUSHBUTTONN.C. SWITCHN.O. SWITCHSWITCHTRANSFORMERCURRENT TRANSFORMERPOTENTIAL TRANSFORMERAMPERE RATINGDRAW-OUT TYPE,AMPERE RATINGTHERMAL MAGNETIC MOLDEDCASE CIRCUIT BREAKERDESIGNATION INDICATESTHERMAL MAGNETIC MOLDEDCASE CIRCUIT BREAKERDESIGNATION INDICATESSYMBOLDESCRIPTIONSWITCHDESCRIPTIONSYMBOLBRANCH CIRCUIT240/120V REFER TOPANELBOARD 208Y/120V ORPANELBOARD SCHEDULE1200A MAX REFER TO800A MAX REFER TODISTRIBUTION PANELBOARDPANELBOARD SCHEDULEDISTRIBUTION PANELBOARDPANELBOARD SCHEDULEMOTOR CONTROL CENTERSWITCHBOARD SECTION120V, (500 KVA SIZE3-45 KVA TRANSFORMER75-225 KVA TRANSFORMERTRANSFORMER 480-208Y/SHOWN) DESIGNATION REFERSTO TRANSFORMER SCHEDULE(800-2000AMP SIZE SHOWN)2500 AMP SWITCHBOARD3000 AMP SWITCHBOARD4000 AMP SWITCHBOARDDOOR HOLDERCONNECTION TO ROOFWALL MOUNTED LOUVERCAPTURE CONTROLSYSTEM TAMPER SWITCHFIRE ALARM SYSTEMEMERGENCY PHONEFLOOR MOUNTED MAGNETICCONNECTION TO MAGNETICDOOR HOLDER PROVIDED BYMOUNTED SMOKE HATCH ORCONNECTION TO SPRINKLERCONNECTION TO ELEVATORCONNECTION TO SPRINKLERFIRE ALARM REMOTEANNUNCIATOR PANELZONE ADDRESS MODULES - SIGNAL DEVICESD - DOOR HOLD OPENSINDIVIDUAL ADDRESS MODULEAUXILLARY POWER SUPPLYCOLLECTIVE ZONE INTERFACEFIRE ALARM CONTROL PANELFLOW SWITCHDOOR HOLDERTHE ARCHITECTSECTIONSECTIONSECTIONMANUAL PULL STATIONDUCT MOUNTED SMOKEWALL MOUNTED MAGNETICLETTER REFERS TO TYPEINDICATES AUXILLIARYVISUAL FIRE ALARM STROBECEILING MOUNTED SMOKECEILING MOUNTED THERMODETECTOR LETTER REFERSTO TYPE IN SPECIFICATIONSAUDIO-VISUAL FIRE ALARMCONTACTS ON FIRE ALARMDEVICEIN DESCRIPTIONDETECTORDETECTORDESCRIPTIONSYMBOLSECTIONSYMBOLDESCRIPTIONTELEPHONE SWITCHREMOTE TELEPHONE RINGERCOMMUNICATIONS EQUIPMENTCABLE TV SPLITTERVIDEO OUTLETRACK/ BUZZERCABLE TV TAPCOMPUTER/DATAWALL MOUNTED CABLECOMMUNICATION OUTLET,DESIGNATION REFERS TODATA COMMUNICATIONSCOMMUNICATION OUTLET, INDESIGNATION REFERS TODATA COMMUNICATIONSTELEPHONE OUTLET INTELEVISION SYSTEM OUTLETCEILING MOUNTED CABLETELEVISION SYSTEM OUTLETWIRING SCHEDULEFLUSH FLOOR BOX,WIRING SCHEDULETELEPHONE OUTLETFLUSH FLOOR BOXCOMPUTER/DATACOMPUTER/DATADESCRIPTIONSYMBOLCEILING MOUNTED CARBONMONOXIDE DETECTORFAN SHUTDOWNADDRESSABLE MONITOR MODULESMOKE DAMPERVOICE CONTROL CENTER PANELANNUNCIATOR PANELNOTIFICATION APPLIANCEEXTENDER PANEL- KEY OPERATEDSINGLE POLE LIGHT SWITCHORWALL MOUNTED DIGITALCLOCK LETTER REFERS TOTYPE IN SPECIFICATIONSWALL MOUNTED CLOCK ANDSPEAKER LETTER REFERS TOTYPE IN SPECIFICATIONSWIRELESS CLOCK TRANSMITTERNSDGFIMEOSOSLCEMPCTCa,bS4S3SKSosSSTGASVSGFFSSDFFHCOAUXFFACPRAPVCCPNAEPZAMIAMPPCCTVCCTVPTZCEILING MOUNTEDOCCUPANCY SENSORVSRAREA OF REFUGE CALL STATIONCEILING MOUNTED VISUAL FIRE ALARM STROBECEILING MOUNTED AUDIO-VISUAL FIRE ALARMFFGROUND FAULT INTERRUPTERDUPLEX RECEPTACLEREQUIRED 2020 IECC ENERGY CONSERVATION COMPLIANCECODE SECTIONCOMPLIANCEC303.3 OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO OWNER BY CONTRACTOR FOR ALL EQUIPMENTC401.2 BUILDING COMPLIES WITH THE APPLICABLE SECTIONS OF CODE BASED ON METHOD 2C402.5 REFERENCE ARCHITECTURAL PLANS FOR AIR LEAKAGE CRITERIA C403.2.1HVAC LOAD SIZING HAS BEEN PERFORMED IN THE CARRIER HAP PROGRAM, USING RTS (HEAT BALANCE) METHODOLOGYC403.2.3 ALL HVAC EQUIPMENT MEETS OR EXCEEDS MINIMUM EFFICIENCIES, REFERENCE MECHANICAL DOCUMENTSC403.2.4 REQUIRED HVAC CONTROLS SHALL BE PROVIDED, REFERENCE MECHANICAL DOCUMENTSC403.2.4.3MOTORIZED DAMPERS PROVIDED FOR EXHAUST AND OUTSIDE AIR INTAKES GREATER THAN 300 CFM OR IN BUILDINGS 3 STORIES OR LESSC403.2.9.1 DUCT IS REQUIRED TO BE INSULATED TO THE INDICATED MINIMUM LEVEL, REFERENCE MECHANICAL DOCUMENTSC403.2.9.3 INSTALLING CONTRACTOR SHALL ENSURE THAT ALL AIR DISTRIBUTION COMPONENTS ARE PROPERLY SEALEDC403.2.9.5 DUCT SIZING AND DUCT DESIGN HAS BEEN PERFORMED, REFERENCE MECHANICAL DOCUMENTSC403.2.10 ALL PIPING INSULATION CRITERIA HAS BEEN MET, REFERENCE MECHANICAL / PLUMBING DOCUMENTSC403.2.11 MECHANICAL SYSTEMS SHALL BE COMMISSIONED AS REQUIREDC404.2 ALL WATER HEATING EQUIPMENT MEETS OR EXCEEDS MINIMUM EFFICIENCIES, REFERENCE PLUMBING DOCUMENTSC404.4 ALL DOMESTIC HOT WATER PIPING INSULATION CRITERIA HAS BEEN MET, REFERENCE PLUMBING DOCUMENTSC405.2 LIGHTING CONTROL CRITERIA HAS BEEN MET, REFERENCE ELECTRICAL DOCUMENTSC405.5 EXTERIOR LIGHTING TOTAL POWER DOES NOT EXCEED THE ALLOWANCE, REFERENCE ELECTRICAL DOCUMENTSC405.6 ELECTRICAL POWER HAS BEEN PROVIDED PER THE CODE REQUIREMENTS, REFERENCE ELECTRICAL DOCUMENTSC408.2.2 INSTALLING CONTRACTOR SHALL TEST AND BALANCE ALL HVAC SYSTEMS AND PROVIDE REPORT TO ENGINEERMECHANICAL DESIGN CONFORMS TO 2020 IECC AND IMC CODE REQUIREMENTSC103.2.1REFERENCE ARCHITECTURAL PLANS FOR FENESTRATION U-FACTORS AND SOLAR HEAT GAIN COEFFICIENTSREFERENCE ARCHITECTURAL PLANS FOR AREA-WEIGHTED U-FACTORS AND SOLAR HEAT GAIN COEFFICIENTSC103.2.2C103.2.3C103.2.4C103.2.5C103.2.6C103.2.7C103.2.8C103.2.9C103.2.10C103.2.11C103.2.12REFERENCE MECHANICAL AND PLUMBING DOCUMENTS FOR DUCT AND PIPE INSULATION MATERIALS, ARCHITECTURAL DOCUMENTS FOR ALL OTHER INSULATION MATERIALSREFERENCE MECHANICAL AND PLUMBING DOCUMENTS FOR EQUIPMENT TYPES, SIZES AND EFFICIENCIESREFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENT TYPES, SIZES AND EFFICIENCIESREFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENTAMD SYSTEM CONTROLSREFERENCE MECHANICAL DOCUMENTS FOR EQUIPMENT HORSEPOWER AND CONTROLSREFERENCE MECHANICAL AND PLUMBING SPECIFICATIONS FOR SEALING AND INSULATION LOCATIONSREFERENCE ELECTRICAL DOCUMENTS FOR LIGHTING FIXTURE SCHEDULE AND CONTROLSREFERENCE ELECTRICAL DRAWINGS FOR DAYLIGHTING ZONESREFERENCE MECHANICAL SPECIFICATIONS FOR AIR SEALING DETAILSRPTWO WAY COMMUNICATION CALL BOXRATH MODEL 2100 CALL BOXNOTES:THE PROJECT IS DESIGNED UNDER THE 2020 NYS STRETCH CODES, 2020 NYS IECC, ASHRAE 90.1-2006, ITHACA GREEN BUILDING POLICY INITIATIVE,WELL BUILDING DESIGN CRITERIA VERSION 2, LEED VERSION 4.1, BASE TAX ABATEMENT AND ENHANCED ENERGY ABATEMENT AS WELL AS THE 2018 FGI REQUIREMENTS FOR OUTPATIENT FACILITIES.INCLUSIVE OF THE PROGRAMS LISTED ABOVE, LEED AND WELL BUILDING CREDITS ARE BEING PURSUED THAT SPECIFICALLY IMPACT THE ELECTRICAL SCOPE. MATERIALS, LIGHTING QUALITY, LIGHTING CONTROLS, LIGHTING POWER DENSITY, ETC. CONTRACTOR TO REVIEW ALL REQUIREMENTS PRIOR TO BID, ALL EQUIPMENT AND MATERIALS TO MEET OR EXCEED THE REQUIREMENTS OF THE PROGRAMS LISTED.THIS PROJECT WILL BE COMMISSIONED. REFERENCE SPECIFICATION SECTIONS 260800 AND 019113 FOR COMMISSIONING REQUIREMENTS.803573SNSEWYORKOFETAT SSOIANLEOFPRLI C E N S E DREENIGN ETRASS N EJ.CIRER EXCELSIOR°°°°°°°°DATE:PROJECT:OTHER:DRAWN BY:ABCDEFGABCDEFG1234567891012345678910ArchitecturePlanningInterior Design1112HI1112HI619 West State StreetIthaca, New York 14850132 E. Jefferson StreetSyracuse, New York 13202p 607 273 7600 www.holt.com2/10/2021 1:56:07 PME001LEGEND &ABBREVIATIONS02/05/20212018089RSCayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGTO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGMENT, THE PLANS AND SPECIFICATIONS ARE IN COMPLIANCE WITH THE INTERNATIONAL ENERGY CODE, AS ADOPTED BY THE STATE.ENERGY CONSERVATION CODE COMPLIANCE STATEMENTREVISION SCHEDULENAME DATEReceived by DiMarco 2/15/2021