HomeMy WebLinkAboutC108 Utility PlanHV A C BUILDING A4 STORY APARTMENT BUILDING11,968 SF42 UNITSXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX0+001+002+003+004+005+00XXXXXASSUMED INV = 378.9Wc/oc/oPROPOSED INV. 12" HDPE W 382.61WWWW W W W W WWWWWWWWWWWWW W W W W WWWWWWWWWWWWWWWWWWWWW WWWPROPOSED 6" DIAMETER SDR-35 SANITARYLATERAL AT 1% MINIMUM. PROVIDE CLEANOUT5' FROM THE BUILDING AND AT CONNECTIONTO MAINPROPOSED 6" CLASS 52 DIP WATER SERVICE. PROVIDE KENNEDY RESILIENTSEAT M.J. GATE VALVE AT MAIN AND AT BUILDING. BACKFLOW AND METERTO BE INSTALLED IN MECHANICAL ROOM. CONNECT NEW SERVICE TOEXISTING MAIN WITH TAPPING SLEEVE AND VALVE. PROVIDE DISINFECTIONAND SAMPLING TAP AT MAIN AND AT BUILDINGCORE AND CONNECTNEW SANITARY LATERALTO EXISTING MANHOLE.UNDERGROUNDWATER QUALITY UNITADJUST VALVES TOGRADE AS NEEDED(TYP.)PROPOSED POTABLEWATER FOUNTAINCONNECT AT EXISTING VALVERELOCATE HYDRANT ASSEMBLYSEE DETAILPROPOSED YARDHYDRANT. SEEDETAIL2" K COPPER WATERSERVICE (TYP.)OS-0 (5' DIA DOGHOUSE MH)DA-10 (2'x2'CB)TG=385.30NW INV=382.40DA-9 (2'x2'CB)TG=385.20SE INV=382.35NW INV=382.58SW INV=382.35DA-8.1 (2'x2'CB)TG=386.90NW INV=383.90DA-6.1 (2'x2'CB)TG=388.50W INV=386.00DA-6 (4' DIA INLET MH)TG=388.50E INV=385.87NE INV=381.66S INV=381.66DD-3 (2'x2'CB)TG=385.40NE INV=382.80DD-2 (2'x2'CB)TG=385.60SW INV=382.70E INV=382.70DA-0 (WATER QUALITY UNIT)TG=389.10SW INV=381.02W INV=380.52DA-5 (4' DIA INLET MH)TG=389.40N INV=381.54S INV=381.54DA-9.2 (YARD INLET)TG=384.60SE INV=382.95DA-9.1 (YARD INLET)TG=384.70NW INV=382.89SE INV=382.8924 L F 1 2 " H D P E STM . @ 0 . 2 0 %24 LF 12" HDPESTM.@ 0.50%25 LF 12" HDPESTM.@ 0.50%44 LF 12" HDPESTM.@ 0.20%163 LF 12" HDPESTM.@ 0.25%85 LF 15" HDPESTM.@ 0.20%56 LF 18" HDPESTM.@ 0.20%50 LF 12" HDPESTM.@ 0.20%26 LF 6" PVCSTM.@ 0.20%6 LF 6" PVCSTM.@ 5.00%20 LF 24" HDPESTM.@ 0.08%68 LF 18" HDPESTM.@ 0.20%PROPOSED HYDRANTASSEMBLY SEE DETAIL12"X6" TAPPING SLEEVE. FORM CONC.THRUST BLOCK AGAINST UNDISTURBEDSOIL. SEE DETAILS (TYP.)CLASS 52 6" D.I. ANCHOR PIPE (TYP.)DISCHARGE TOGRADE PROVIDESPLASH BLOCKPROPOSED SEWER SERVICE CLEANOUT.SEE DETAILFORM CONC. THRUST BLOCK AGAINSTUNDISTURBED SOIL. SEE DETAIL (TYP.)PROPOSED 4"PERFORATED HDPEUNDERDRAIN (TYP.)DD-0 (2'x2' CB)TG=385.80NW INV=382.44POWER POLE RELOCATIONTO BE COORDINATED BYCONTRACTORDDA-4 (4' DIA STORM MH)TG=389.50N INV=381.40SW INV=381.4089 LF 18" HDPESTM.@ 0.20%CROSSING CHECK:INV. SAN. PIPE=371.18INV. STM. PIPE =385.49CROSSING CHECK:INV. SAN. PIPE=371.18INV. STM. PIPE =385.49REFER TO PUBLIC CONNECTIONNOTES FOR CONNECTIONS WITHINCITY EASEMENTS AND R.O.W.CONTRACTOR SHALL LOWER EXISTINGWATERMAIN AT LOCATION TO AVOIDCONFLICT AND PROVIDE 18" OFSEPARATION AS REQUIRED60 LF 18" HDPESTM.@ 0.20%CONTRACTOR SHALL LOWER EXISTINGWATERMAIN AT LOCATION TO AVOIDCONFLICT AND PROVIDE 18" OFSEPARATION AS REQUIRED32 L F 6 " P V C STM. @ 1 . 0 0 %2" GATE VALVE2"X1"X2" TEE2"X2"X1" TEEFP = 388.0PROPOSED INV. 6" PVC W 381.12PROPOSED INV. 6" PVC SE 382.66EPPPPS 35°56'24" W MAPTHI R D S T R E E T CARPENTER PARKMATCH LINEMATCH LINE DA-8 (4' DIA INLET MH)TG=386.90SE INV=383.78NE INV=381.95NW INV=383.78SW INV=381.95DA-7.1 (2'x2'CB)TG=388.50NW INV=385.5026 LF 12" HDPESTM.@ 0.50%13 LF 8" PVCSTM.@ 1.00%DA-7 (4' DIA INLET MH)TG=387.90NE INV=381.78SE INV=385.37SW INV=381.78PROPOSED YARDHYDRANT. SEE DETAILUTILITY NOTES:1.PRIOR TO THE START OF UTILITY INSTALLATION THE CONTRACTOR AND SUBCONTRACTOR IS RESPONSIBLE FORCOORDINATION OF ALL UTILITY CONNECTIONS WITH MECHANICAL/ARCHITECTURAL DRAWINGS FOR INCLUDING BUTNOT LIMITED TO VERTICAL AND HORIZONTAL LOCATION, PENETRATIONS, AND SIZES. THE CONTRACTOR SHALL OBTAINWRITTEN PERMISSION TO PROCEED WITH UTILITY INSTALLATION BY THE OWNERS ONSITE REPRESENTATIVE UPONCOMPLETION OF COORDINATION WITH CONTRACTORS, AND PLANS.2.THE DEVELOPER AND HIS/HER CONTRACTOR IS RESPONSIBLE FOR COORDINATING GAS, ELECTRICAL, CABLE,TELEPHONE AND ANY OTHER UTILITIES NOT SPECIFICALLY SHOWN WITHIN THIS PLAN SET WITH APPROPRIATE AGENCY.PASSERO ASSOCIATES ASSUMES NO RESPONSIBILITY FOR THE DESIGN OR PERFORMANCE OF UTILITIES NOTSPECIFICALLY SHOWN WITHIN THIS PLAN SET.3.PRIOR TO THE START OF UTILITY INSTALLATION THE CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES VERTICALLYAND HORIZONTALLY AND COORDINATE WITH EXISTING UTILITIES SHOWN ON THE PLANS AND REPORT ANYDISCREPANCIES TO THE DESIGN ENGINEER. THE CONTRACTOR SHALL OBTAIN WRITTEN PERMISSION TO PROCEED WITHUTILITY INSTALLATION BY THE OWNERS ONSITE REPRESENTATIVE UPON COMPLETION EXISTING UTILITY VERIFICATION.4.ALL PROPOSED UTILITIES SHALL BE CONSTRUCTED IN CONFORMANCE WITH THE LATEST REGULATIONS OF THE STATE,COUNTY AND LOCAL MUNICIPALITY OR PURVEYOR.STORM SEWER NOTES1.REGULATIONS - STORM SEWERS AND APPURTENANCES SHALL BE CONSTRUCTED IN CONFORMANCE WITH THE LATESTREGULATIONS OF THE MUNICIPALITY2.MATERIALS - THE CONTRACTOR MAY USE THE FOLLOWING PIPE MATERIAL FOR THE MAIN SEWER AS ALLOWED BY THEMUNICIPALITY, PROVIDING THAT THE ROUGHNESS COEFFICIENT ("N" FACTOR) IS 0.013 OR BETTER:·REINFORCED CONCRETE PIPE (RCP), CLASS III·CORRUGATED STEEL PIPE (CSP), 16 GAUGE·HIGH DENSITY CORRUGATED POLYETHYLENE PIPE (PE), AASHTO M-29, TYPE S, ASTM D-3350.3.ROOF DRAINAGE - ALL ROOF DRAINAGE SHALL BE COLLECTED AND PIPED TO THE STORM SEWER SYSTEM UNLESSSPECIFIED OTHERWISE.4.TESTING - UPON COMPLETION OF SYSTEM INSTALLATION, THE MAIN SEWER SYSTEM AND LEADS TO STRUCTURES SHALL BEFLUSHED AND LAMPED TO THE SATISFACTION OF THE MUNICIPALITY.GWEXIST. ELECTRIC LINEEXIST. LIGHT POLEEXIST. GAS MAINEXIST. WATER MAINEXISTING EASEMENT LINELPEMHHHGVCBEXIST. ELECTRIC MANHOLEEXIST. ELECTRIC HANDHOLEEXIST. GAS VALVEPROPOSED EASEMENT LINEEPROPOSED UNDERGROUND ELECTRICEPROPOSED BUILDINGPROPOSED STORM SEWER, INLETMH, CB & END SECTIONEXISTING SANITARY SEWER ANDMANHOLEPROPOSED WATER SERVICEW/ HYDRANT & VALVEPROPOSED SANITARY SEWERAND MANHOLEEXISTING WATER SERVICE& VALVESSMHEXISTING STORM SEWER & MHHYDEXISTING ELECTRIC LINE & POLEPPWEXISTING FENCEWVLEGEND:PROPERTY BOUNDARYEXISTING CENTER LINE ROADEXISTING BUILDINGR.O.W.R.O.W.PROPOSED SIGNPROPOSED LIGHTPROPOSED CONCRETEDOHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW No.RevisionsARTICLE 147 SECTION 7307. THESE PLANS ARE COPYRIGHT PROTECTEDVIOLATION OF STATE EDUCATION LAW ARTICLE 145 SECTION 7209 ANDUNAUTHORIZED ALTERATIONS OR ADDITIONS TO THIS DRAWING IS INcDateByDescriptionSheet No.Project No.DateDrawing No.Scale:Designed byProject ManagerPrincipal-in-ChargePASSERO ASSOCIATESClient:StampPASSERO ASSOCIATESEngineeringwww.passero.comArchitecture224 West Main Street, Suite 100(585) 325-1000Rochester, New York 14614Fax: (585) 325-1691PARK GROVE REALTY, LLC46 PRINCE STREETROCHESTER, NY 14607Jess Sudol, PEMatthew NewcombTrevor Haut, EITCAYUGA PARKCITY OF ITHACATOMPKINS COUNTYSTATE OF NEW YORK20172440.0001AUGUST 2020CITY OF ITHACASITECAYU G A I N L E T N M E A D O W S TCASCADILLA ST3R D S T E X N 3RD STADAMS STADAMS S T4TH ST5TH STHANCOCK S T MADISON S T MORR I SAVEN F U L T O N S T OLD TAUGHANNOCK BLVDDRAWING INDEXC101 COVERC102 - 104 EX. CONDITIONS & DEMO PLANC105 - 107 LAYOUT PLANC108 - 110 UTILITY PLANC111 - 113 GRADING PLANC114 PROFILESC115 - 117 LIGHTING PLANC201 - 203 DETAILSNOT FOR CONSTRUCTION00201040SCALE: 1"=20'HORIZONTAL SCALE20UTILITY PLANC 10881" = 20'HYDRANT FLOW DATA:Q OBSERVED = 1,900 gpmQ psi = 2,987 gpmLOCATION: CARPENTER PARK #G300P. STATIC = 94 psiP. RESIDUAL = 62 psiDATE: 2019ELEVATION: 387PUBLIC CONNECTION NOTES:1.PRIOR TO THE START OF UTILITY CONNECTIONS TO PUBLIC INFRASTRUCTURE THECONTRACTOR AND/OR SUBCONTRACTOR IS RESPONSIBLE FOR COMPLETING A WATER &SEWER TIE IN APPLICATION WITH THE CITY OF ITHACA THREE (3) WEEKS PRIOR TO THEANTICIPATED WORK DATE.2.CONTRACTOR WILL COORDINATE WITH CITY PERSONNEL IN INSTALLATION PROJECT.3.CITY WILL PERFORM WORK WITHIN PUBLIC EASEMENT / RIGHT-OF-WAY AT A NOMINAL RATE.CITY OF ITHACA WATER NOTES:GENERALDESCRIPTION OF WORK AND MATERIALS·THIS WORK SHALL CONSIST OF FILLING THE WATER MAIN AND APPURTENANCES WITH WATER AND BLEEDING OFF ALL ENTRAPPED AIR, ALLOWING THE PIPE LINE TO SOAK, MAKING ALLCONNECTIONS TO THE WATER MAIN FOR EXPELLING AIR AND FOR TESTING EQUIPMENT; RUNNING THE TEST, VISUALLY INSPECTING EXPOSED APPURTENANCES, LOCATING ANDREPAIRING ALL LEAKS, RETESTING, APPLICATION OF DISINFECTANT, AND FLUSHING OPERATIONS.·MATERIALS FURNISHED FOR THIS WORK SHALL INCLUDE, BUT NOT BE LIMITED TO, PIPE AND FITTINGS FOR CONNECTIONS TO THE MAIN, PUMPS, PRESSURE REGULATOR, A CALIBRATEDCONCENTRATION MIX TANK, DISINFECTANT, AND ALL OTHER MATERIALS, FITTINGS AND PIPELINES REQUIRED TO PERFORM THE TESTS AND MAKE THE NECESSARY REPAIRS.REQUIRED WORK SEQUENCE·THE PRESSURE TEST AND THE TEST FOR ALLOWABLE LEAKAGE SHALL BE PERFORMED SIMULTANEOUSLY. TESTING SHALL NOT COMMENCE UNTIL THE WATER MAIN AND ALLAPPURTENANCES HAVE BEEN COMPLETELY INSTALLED, UP TO AND INCLUDING COMPACTION OF ROAD AGGREGATE BASE. AFTER SUCCESSFULLY TESTING THE WATER MAIN ANDAPPURTENANCES, THEY MAY THEN BE FLUSHED AND DISINFECTED.SYSTEM OPERATIONS·ONLY WATER & SEWER PERSONNEL SHALL OPERATE VALVES AND APPURTENANCES THAT ARE A PART OF THE TREATED WATER SYSTEM IN ACTIVE SERVICE.BACKFLOW PREVENTION·ALL CONNECTION FROM THE TESTING AND DISINFECTION APPARATUS TO THE EXISTING DISTRIBUTION SYSTEM SHALL BE FITTED WITH A UL APPROVED BACKFLOW PREVENTION DEVICE(DOUBLE CHECK VALVE ASSEMBLY OR REDUCED PRESSURE PRINCIPLE TYPE) LOCATED AT THE EXISTING TREATED WATER MAIN OR APPURTENANCE.TESTINGHYDROSTATIC PRESSURE AND LEAK TESTING SHALL BE PERFORMED ON NEW WATER MAINS IN ACCORDANCE WITH AWWA C600 “INSTALLATION OF DUCTILE IRON MAINS AND THEIRAPPURTENANCES” (LATEST EDITION).IN GENERAL, THE TESTING EQUIPMENT CONFIGURATION SHALL CONSIST OF A DOUBLE CHECK VALVE FROM ANEXISTING TREATED WATER MAIN OR WATER SOURCE, A LENGTH OF FLEXIBLECOPPER PIPE, A PRESSURE TEST GAUGE WITH A RANGE OF AT LEAST 200 PSI, A PUMP, AND THE NECESSARY COMPRESSION COUPLINGS AND FITTINGS REQUIRED TO CONNECT THE LINETHROUGH A TAP IN THE MAIN OR APPURTENANCE. PRIOR TO TESTING, THE WATER MAIN SHALL BE SLOWLY AND CAREFULLY FILLED WITH WATER, PREFERABLY FILLING FROM THE LOWESTELEVATION POINT IN THE LINE TO ALLOW ALL AIR TO BE EXPELLED SLOWLY FROM THE PIPE AND APPURTENANCES AT THE TOP MOST ELEVATION POINT. ALL APPURTENANCES SHALL BE LEFT ONDURING THE TESTING PROCEDURE. THE TEST PRESSURE SHALL BE PROVIDED BY AN IN-LINE PUMP UNTIL 150% OF THE WORKING PRESSURE, AS CALCULATED FOR THE LOWEST ELEVATION OF THETEST SECTION, OR 150 PSI, WHICHEVER IS GREATEST, IS ACHIEVED. THE TEST DURATION SHALL BE A MINIMUM OF 2 HOURS. ALLOWABLE LEAKAGE PER TEST SECTION IS PERMITTED BASED ONTHE FORMULA BELOW. DIFFERENT SIZED WATER MAINS THAT MIGHT BE CONTAINED WITHIN THE SAME TEST SECTION AND SHALL BE CALCULATED SEPARATELY AND THEIR ALLOWABLE LEAKAGEADDED TOGETHER. THIS FORMULA REPRESENTS THE ALLOWABLE LEAKAGE REGARDLESS OF THE NUMBER OF JOINTS, COUPLINGS, FITTINGS, VALVES, PRESSURE REDUCING OR PUMP STATIONOR ANY OTHER APPURTENANCES ON THE WATER MAIN. THE LENGTH OF PIPE CONTAINED IN THESE APPURTENANCES SHALL NOT BE COUNTED AS ADDING TO THE LENGTH OF WATER MAINBEING TESTED.V = (L)(D)(P)^(12)/148,000V = ALLOWABLE LEAKAGE IN GALLONS PER HOURL = LENGTH OF WATER MAIN IN FEETD = NOMINAL DIAMETERP = AVERAGE TEST PRESSURE IN PSI****THE AVERAGE TEST PRESSURE SHALL BE CALCULATED AS THE TEST PRESSURE FOR THE LOWEST ELEVATION OF THE TEST SECTION LESS ONE-HALF THE ELEVATION CHANGE TO THE HIGHESTPOINT ON THE TEST SECTIONREPAIRSDURING THE PRESSURE AND LEAKAGE TEST, ALL ACCESSIBLE APPURTENANCES SHALL BE INSPECTED FOR VISUAL SIGNS OF LEAKAGE. ALL VISUAL LEAKS SHALL BE CORRECTED IMMEDIATELY, REGARDLESS OFTHE AMOUNT OF LEAKAGE AND THE TEST SHALL BE RUN AGAIN FOR ITS FULL DURATION. SHOULD THE PRESSURE AND LEAKAGE TEST FAIL, CITY WATER & SEWER SHALL BEGIN TO INVESTIGATE ALL AREAS OFSUSPECTED LEAKAGE AND SHALL MAKE ALL REPAIRS NECESSARY IN ORDER TO AFFECT A SUCCESSFUL TEST. ALL LEAKS DETECTED SHALL BE REPAIRED TO A WATER TIGHT CONDITION. ALL REPAIRS MADE SHALLBE RETESTED IN ACCORDANCE WITH THESE SPECIFICATIONS. ALL REPAIRS SHALL BE MADE AND A SUCCESSFUL TEST ACCOMPLISHED PRIOR TO TAKING BACTERIOLOGICAL SAMPLES.DISINFECTINGTHE INTERIOR OF ALL WATER MAINS AND APPURTENANCES SHALL BE DISINFECTED IN ACCORDANCE WITH AWWA C651 “DISINFECTING WATER MAINS” (LATEST EDITION) AND THESE SPECIFICATIONS.DISINFECTION REQUIREMENTS SHALL INCLUDE PREVENTIVE AND CORRECTIVE MEASURES DURING CONSTRUCTION, FORMS OF CHLORINE AND METHODS OF APPLICATION, FINAL FLUSHING, ANDBACTERIOLOGICAL TESTS.PRECAUTIONS SHALL BE TAKEN TO PROTECT THE INTERIOR OF WATER MAINS AND APPURTENANCES AGAINST CONTAMINATION. THE OPEN ENDS OF ALL WATER MAIN LAID IN THE TRENCH SHALL BE CLOSEDWITH WATER TIGHT PLUGS WHEN PIPE LAYING HAS STOPPED. STOCKPILED PIPE AND APPURTENANCES SHALL ALSO BE PROTECTEDFROM CONTAMINATION.IF DIRT OR OTHER CONTAMINANTS ENTER THE WATER MAIN OR APPURTENANCES AND, IN THE OPINION OF THE CITY WATER & SEWER ENGINEERS, THE CONTAMINATION WILL NOT BE REMOVED BY THEFLUSHING OPERATION, THE INTERIOR SURFACES SHALL BE CLEANED BY MECHANICAL MEANS.CITY WATER & SEWER UTILIZES A SLUG METHOD FOR DISINFECTION. IN GENERAL, THE DISINFECTION EQUIPMENT CONFIGURATION SHALL CONSIST OF A DOUBLE CHECK VALVE, FLEXIBLE COPPER PIPE, THENECESSARY COMPRESSION FITTINGS REQUIRED TO CONNECT AN EXISTING TREATED WATER MAIN OR SOURCE TO THE DISINFECTION EQUIPMENT AND TO THE NEW MAIN OR APPURTENANCE SUBJECT TODISINFECTION, CALIBRATED CONCENTRATION MIX DRUM, 12.5% SOLUTION OF SODIUM HYDROXIDE, AND A VENTURI BASED CONCENTRATION EDUCATOR.THE METHOD CONSISTS OF CALCULATING THE VOLUME OF THE MAIN TO BE DISINFECTED AND CREATING A SOLUTION OF SODIUM HYPOCHLORITE WHERE, USING A CALIBRATED EDUCATOR, DISTRIBUTESENOUGH CHLORINE SOLUTION INTO THE MAIN TO ACHIEVE A CONCENTRATION OF 100PPM. ONCE FILLED, THE MAIN IS ALLOWED TO SIT FOR A MINIMUM OF 24 HOURS.FINAL FLUSHINGTHE HEAVILY CHLORINATED WATER SHALL BE FLUSHED FROM THE MAINS AND APPURTENANCES AND SHALL NOT REMAIN IN THE MAINS MORE THAN 48 HOURS BEYOND THE TIMES REQUIRED IN THIS SECTION.THE HEAVILY CHLORINATED WATER SHALL PASS THROUGH A DECHLORINATOR FILLED WITH VITAMIN C TABLETS PRIOR TO DISPOSAL. THE MAIN SHALL BE FLUSHED UNTIL MEASUREMENTS SHOW THAT THECHLORINE CONCENTRATION IN THE PIPE IS NO HIGHER THAN THAT GENERALLY PREVAILING IN THE SYSTEM, BUT NOT MORE THAN 1.0 MG/L.BACTERIOLOGICAL SAMPLESUPON COMPLETION OF THE DISINFECTION PROCESS, WATER SAMPLES SHALL BE TESTED FOR BACTERIOLOGICAL QUALITY IN ACCORDANCE WITH AWWA "STANDARD METHODS FOR THE EXAMINATION OFWATER AND WASTEWATER" AND SHALL SHOW THE ABSENCE OF COLIFORM ORGANISMS. TESTING SHALL BE PERFORMED AT THE ITHACA WATER TREATMENT PLANT LABORATORY. SHOULD ANY OF THESAMPLES PROVE POSITIVE, CITY WATER & SEWER SHALL REPEAT THE DISINFECTING PROCESS AND ADDITIONAL SAMPLES WILL AGAIN BE COLLECTED FOR TESTING.CITY OF ITHACA SEWER MAIN AND APPURTENANCE NOTES:SCOPETHIS SECTION DESCRIBES THE SPECIFICATIONS FOR SEWER MAIN AND SERVICE DESIGN, PLANNING AND INSTALLATION.REFERENCES AND REGULATORY APPROVALSUNLESS OTHERWISE DIRECTED BY THE TOMPKINS COUNTY HEALTH DEPARTMENT (TCHD), SEWER COLLECTION SYSTEM PLANNING, DESIGN, INSTALLATION, AND TESTING SHALL FOLLOW TEN STATES STANDARDS. AT LEAST ANNUALLY, THE CITY WATER & SEWERDEPARTMENT WILL NOTIFY TCHD OF EACH PLANNED CAPITAL IMPROVEMENT PROJECT WHICH WILL INCLUDE A BRIEF NARRATIVE OF THE PURPOSE AND INTENT OF THE PROJECT AS WELL AS AN APPROXIMATION FOR SCHEDULING. TCHD SHALL ALSO BE NOTIFIEDWHEN INSTALLATION OF REPLACEMENT MAIN IS COMPLETE. IN THE CASE OF AN EMERGENCY MAIN REPLACEMENT, TCHD SHALL BE NOTIFIED IMMEDIATELY. SPECIFIC HEALTH DEPARTMENT PROJECT REVIEW AND APPROVAL BEYOND THIS INITIAL NOTIFICATIONSHALL BE REQUIRED IF ANY OF THE FOLLOWING CONDITIONS EXIST:1.ANY SEWER MAIN EXTENSION FOR WHICH THERE IS CURRENTLY NO COLLECTION SYSTEM INFRASTRUCTURE.2.ANY DESIGN INCREASE IN SEWER CAPACITY FOR WHICH TO SPECIFICALLY ACCOMMODATE FUTURE DEVELOPMENT, OR THAT WHICH IS ABOVE AND BEYOND MINIMUM CONSTRUCTION STANDARDS. FOR EXAMPLE, AN UPGRADE FROM AN 8” TO A 12”DIAMETER LINE IN ANTICIPATION OF FUTURE APARTMENT CONSTRUCTION WOULD BE REQUIRED FOR SUBMISSION TO THE HEALTH DEPARTMENT FOR APPROVAL. HOWEVER, A STANDARD UPGRADE FROM A 6” CLAY TILE TO AN 8” PVC DIAMETER LINE TO REPLACEAGING INFRASTRUCTURE AND MEET A TYPICAL CONSTRUCTION STANDARD WOULD NOT BE REQUIRED FOR REVIEW. IN THIS CASE, THE STANDARD NOTIFICATION PROCEDURE DESCRIBED ABOVE WILL BE FOLLOWED.GENERAL PLANNING, DESIGN AND INSTALLATIONCITY WATER & SEWER ENGINEERING STAFF PROVIDE FOR THE PLANNING AND DESIGN OF ALL SEWER RELATED INFRASTRUCTURE. A TYPICAL ENGINEERING PROFILE IS DEVELOPED IN PROJECTS WHERE EXCESSIVE SLOPE IS ANTICIPATED, WHERE THE LAYOUT ORNUMBER OF EXISTING OR PROPOSED UNDERGROUND UTILITIES COULD BE CAUSE FOR CONCERN OR INTERFERENCE, OR IF THE PROJECT IS WORKING CLOSELY WITH OTHER DEVELOPMENT AND CONSTRUCTION ACTIVITY. SANITARY PROJECTS LOCATED IN AREASOF MINIMAL SLOPE DO NOT TYPICALLY REQUIRE AN ENGINEERED PLAN PROFILE AND ARE INSTEAD GUIDED CAREFULLY IN THE FIELD BY SURVEY TEAMS.CITY WATER & SEWER CONSTRUCTION CREWS INSTALL COLLECTION SYSTEMS AND SERVICES AT OR BELOW FROST DEPTH (TYPICALLY A MINIMUM OF 4.5’ BELOW THE SURFACE) WITH CARE TO ENSURE THAT AT LEAST 10’ OF PARALLEL SEPARATION FROM OUTSIDEWALL TO OUTSIDE WALL OF ANY EXISTING OR PROPOSED WATER MAIN IS ACHIEVED. IN CASES WHERE IT IS IMPRACTICAL TO MAINTAIN 10’ OF SEPARATION, THE TOMPKINS COUNTY HEALTH DEPARTMENT WILL BE CONSULTED TO REVIEW A WAIVER OF THE RULEON A CASE-BY-CASE BASIS.SEWER MAINS CROSSING WATER MAINS SHALL BE LAID TO PROVIDE A MINIMUM VERTICAL DISTANCE OF 18” BETWEEN THE OUTSIDE OF THE SEWER MAIN AND THE OUTSIDE OF THE WATER MAIN.SPECIFICATIONS REGARDING MATERIAL, TRENCHING, BEDDING, SERVICES, AND GENERAL APPURTENANCE INSTALLATION MAY BE FOUND ON THE DETAIL SHEETS