HomeMy WebLinkAboutA751 Fifth Floor Finish Plan Sector 1CORNER GUARD 7'-0"H U.O.N.
(TOP @ 7'-4" AFF).
TYPICAL AT ALL OUTSIDE
CORNERS. COORDINATE
WITH MILLWORK
3101
P1
CP1 RB1
ROOM NUMBER
WALL TREATMENT
FLOOR
TREATMENT
BASE TREATMENT
WINDOW SHADES
HANDRAIL. SEE
ELEVATIONS FOR
ADDITIONAL INFORMATION
P2 ACCENT WALL
PAINT COLOR
SS1
PL2
WC
CT
E
C
MILLWORK FINISH KEY:
PL1
WD1
WALL CABINET
FINISH
COUNTERTO
P FINISH
COUNTERTOP
EDGE
TALL OR BASE
CABINET FINISH
ROOM FINISH KEY:
NOTE: REFER TO FINISH SCHEDULE FOR MATERIALS.
SAW1 TACKABLE
ACOUSTIC
SURFACE
WS1
HR1
RESILIENT WALL BASE,
MATCH EXISTING (SHOWN
GRAPHICALLY ONLY
WHEN IN PATCHING
APPLICATIONS)
RB1
CG1 EG2
WALL COVERINGWC1
RIGID VINYL WALL
PROTECTION
WP1
MINARAL PROFILE
FEATURE PANEL
MP1
BACK-PAINTED
GLASS PANEL
PS1
PULL SIDE
* REFER TO ELEVATIONS
MATERIAL FINISH KEY: NOT ALL MAY APPLY
CERAMIC TILE ACCENT CT1
SECTOR 1 SECTOR 2
WP1
WP1
WP1
CG1
CG1 CG1
CG1CG1 CG2 CG2 CG2
CG1CG1
CG1
CG1
CG1CG1
CG1
CG2
CG1 CG1
CG2 CG2
CG2 CG2
CG1
CG1
CG1
CG1
CG2
CG1 CG1
CG1
CG2
WC
CT
E
C
PL2
E1
PL1
SS1
WC
CT
E
C
PL2
E1
PL1
SS1
WC
CT
E
C
PL2
E2
PL5
WC
CT
E
C
PL2
E2
PL5
WC
CT
E
C
PL2
E2
PL5
WC
CT
E
C
PL2
E1
PL1
SS1
WC
CT
E
C
PL2
E1
PL1
SS1
WC
CT
E
C
PL2
E2
PL5 SECTOR 1SECTOR 2SECTOR 2SECTOR 1EXAM/CONSULT
B1
P1
RT2
514
P14
SEE TYPICAL EXAM ACCENT WALL 1
P14
SEE TYPICAL EXAM ACCENT WALL 1
P14
SEE TYPICAL EXAM ACCENT WALL 1
P14
SEE TYPICAL EXAM ACCENT WALL 1
P14
P14
P14
P14
SEE TYPICAL EXAM ACCENT WALL 1 MIRRORED
P14
SEE TYPICAL EXAM ACCENT WALL 1
EXAM/CONSULT
B1
P1
RT2
513
EXAM/CONSULT
B1
P1
RT2
515
EXAM/CONSULT
B1
P1
RT2
519
EXAM/CONSULT
B1
P1
RT2
520
EXAM/CONSULT
B1
P1
RT2
521
EXAM/CONSULT
B1
P1
RT2
522
CENTRAL
CLEAN
WORK
B1
P1
RT2
512
WC
CT
E
C
PL2
E1
PL1
SS1
WC
CT
E
C
PL2
E1
PL1
SS1
WC
CT
E
C
PL2
E1
PL1
SS1
WC
CT
E
C
PL2
E1
PL1
SS1
WC
CT
E
C
PL2
E1
PL1
SS1
EXAM/CONSULT
B1
P1
RT2
516
EXAM/CONSULT
B1
P1
RT2
518
WC
CT
E
C
PL2
E1
PL1
SS1
WC
CT
E
C
PL2
E1
PL1
SS1
WC
CT
E
C
PL2
E1
PL1
SS1
WC
CT
E
C
PL2
E1
PL1
SS1
STAFF
CIRCULATION
B1
P1
RT2
517
NURSE
WORK AREA
B1
P1
RT3
517E
WC
CT
E
C
E2
PL5
PROVIDER
OFFICE
B1
P1
CPT3
517F
IT/ELEC
B1
P1
SC1
523
TRIAGE
NURSE
B1
P1
CPT3
524
PATIENT
TOILET
CT1
P1
CT1
526A
STAFF
TOILET
CT1
P1
CT1
525CT2CT2
SPECIALTY
EXAM/
TREATMENT
RS1
P1
RS1
526
WP1
WC
CT
E
C
PL2
E1
PL1
SS1
PATIENT
TOILET
CT1
P1
CT1
527
P14P14
EXAM/CONSULT
B1
P1
RT2
531
EXAM/CONSULT
B1
P1
RT2
538
EXAM/CONSULT
B1
P1
RT2
537
WC
CT
E
C
PL2
E1
PL1
SS1
WC
CT
E
C
PL2
E1
PL1
SS1
WC
CT
E
C
PL2
E1
PL1
SS1
EXAM/CONSULT
B1
P1
RT2
528
EXAM/CONSULT
B1
P1
RT2
529
WC
CT
E
C
PL2
E1
PL1
SS1
WC
CT
E
C
PL2
E1
PL1
SS1
WC
CT
E
C
PL2
E1
PL1
SS1
EVS
B1
P1
RT2
530
STORAGE
B1
P1
RT2
539C
NURSE
WORK
B1
P1
RT2
539
WC
CT
E
C
E2
PL5
WC
CT
E
C
PL2
E2
PL5
TRIAGE
NURSE
B1
P1
RT2
539B
PROVIDER
OFFICE
B1
P1
CPT3
539A
PATIENT
TOILET
CT1
P1
CT1
536
SPECIMEN
COLLECTION
CT1
P1
CT1
533
LAB DRAW
B1
P1/WP2
RT1
532
LAB
B1
P1
RT2
534
PATIENT
TOILET
CT1
P1
CT1
535A
STORAGE
RS1
P1
RS1
535B
SPECIALTY
EXAM/TREATMENT/
TELEMED
RS1
P1
RS1
535
WC
CT
E
C
PL2
E1
PL1
SS1
P14SEE TYPICAL EXAM ACCENT WALL 2P14SEE TYPICAL EXAM ACCENT WALL 2P14
SEE TYPICAL EXAM ACCENT WALL 2
P14
SEE TYPICAL EXAM ACCENT WALL 2
P14
SEE TYPICAL EXAM ACCENT WALL 2
CT2
CT2
ELEVATOR
CONTROL
ROOM
B1
P1
SC1
500
CT3
STAIR 2
B1
P1
ST1
ST2-5
CIRCULATION
B1
P1
RT1/2
504
CT3 CT3
P14P14
P15
P15
P14P14P14CG1
WS1WS1
WS1WS1WS1
WS1WS1
WS1WS1WS1WS1
CG1 CG1
A1
A550
________________________________________________
A4
A550
________________________________________________
A7
A550
________________________________________________
E7
A550
________________________________________________
A4
A550
________________________________________________RT2RT1RT2
RT1
RT1
RT2
A4
A550
________________________________________________
A7
A550
________________________________________________
A7
A550
________________________________________________
E7
A550
________________________________________________
A4
A550
________________________________________________RT3RT2RT3RT2A1
A550
________________________________________________
C1
A550
________________________________________________
A1
A550
________________________________________________
RT1
RT2
CT3
WP1
WP1
WP1
WP1
WP1
WP1 WP1
CT3
CT2
WP1
ALIGNALIGN1' - 0"11 7/8"1' - 0"
WP2WP2 WP2
WP2
WP2
WP2 WP2 WP2
WP2
WP2
WP2 WP2
WP2
WP2
WP2
WP2
WP2
WP2
WP2
WP2
WP2
WP2
WP2
WP2
WP2
WP2
WP2
WP2
WP1
WP1
WP2
WP2
WP2
WP2
WP2
WP2
WP2
WP1
P19 P19 P19 AT LOW WALL
P19 AT LOW WALLP19 AT LOW WALL
SEE TYPICAL EXAM ACCENT WALL 1 MIRRORED
SEE TYPICAL EXAM ACCENT WALL 1 MIRRORED
SEE TYPICAL EXAM ACCENT WALL 1 MIRRORED P17P2 AT EXPOSED STRUCTURAL
BRACING, COORDINATE WITH
MANUFACTURER REQUIREMENTS TO
COVER INTUMESCENT FIREPROOFING
P2 AT EXPOSED STRUCTURAL
BRACING, COORDINATE WITH
MANUFACTURER REQUIREMENTS TO
COVER INTUMESCENT FIREPROOFING
CT3
CT2
LK1
LK1
P2 (EXPOSED STRUCTURE)
ALUMINUM TRIM,
REFER TO
DETAIL A5/A502
SEAL GAP
PROVIDE EMSEAL
HORIZONTAL COLORSEAL;
COLOR TBD
OPEN TO
BELOW
ALUMINUM TRIM
FINISHED SURFACE OF
SEALANT, FLORING
AND SOLID SUFRAC
SILL TO ALIGN
DN UP
P2 (EXPOSED STRUCTURE)
CONTINUE ALL NOTED
FINISHES UP TO ROOF LEVEL
STAIR LANDING AND
CEILINGS ABOVE
RT1 -RESILIENT TILE FLOORING
NOTE: REFER TO FINISH PLANS AND FINISH SCHEDULE FOR SPECIFIC PRODUCT TYPES
RT2 -RESILIENT TILE FLOORING
RT3 -RESILIENT TILE FLOORING
CT1 -CERAMIC TILE
CPT2 -WALKOFF CARPET TILE
CPT3 -CARPET TILE
CPT4 -CARPET TILE
CPT1 -WALKOFF CARPET TILE
RS1 -RESILIENT SHEET FLOORING
TT1 -TERRAZZO TILE
DATE:
PROJECT:
OTHER:
DRAWN BY:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Architecture
Planning
Interior Design
11 12
H
I
11 12
H
I
619 West State Street
Ithaca, New York 14850
132 E. Jefferson Street
Syracuse, New York 13202
p 607 273 7600 www.holt.com
WARNING: It is a violation of New
York State Law for any person,
unless acting under the direction of
a licensed Architect, to alter this
document in any way. If a document
bearing the seal of an Architect is
altered, the altering Architect shall
affix to such document his seal and
the notation "altered by" followed by
his signature, the date of such
alteration, and a specific description
of the alteration.2/5/2021 4:58:15 PMA751
FIFTH FLOOR
FINISH PLAN -
SECTOR 1
02/05/2021
2018089
KAS/HRT Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGGENERAL FINISH NOTES
FINISH LEGEND
KEY PLAN
KEYED FINISH NOTES
1 ALL WALLS TO BE PAINTED P1 UNLESS OTHERWISE NOTED.
2 ALL HOLLOW METAL FRAMES TO BE PAINTED P17 UNLESS OTHERWISE NOTED.
3 REFER TO INTERIOR ELEVATIONS AND DETAILS FOR ADDITIONAL INFORMATION AND
CLARIFICATION ON EXTENT OF FINISH MATERIALS.
4 ALIGN FLOOR TILE GROUT LINES WITH WALL TILE GROUT LINES.
5 TILE AND PLANK FLOORING UNITS SHALL NOT BE CUT LESS THAN 6” ON ANY EDGE.
6 PROVIDE ARCHITECT WITH A MINIMUM OF (3) 8" X 10" BRUSH-OUTS OF EACH COLOR &
FINISH FOR ARCHITECT'S APPROVAL AT LEAST 2 WEEKS PRIOR TO SITE APPLICATION.
ONSITE APPLICATION WILL BE REQUIRED ONE WEEK PRIOR TO FINAL APPROVAL.
ARCHITECT RESERVES THE RIGHT TO ADJUST ANY COLOR/FINISH ONCE THE WALL
TEST HAS BEEN COMPLETE.
7 PATTERN NAME, COLOR AND NUMBER FOR EACH MATERIAL ARE GIVEN WHEREVER
POSSIBLE ON THE FINISH PLAN. IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO BRING ANY DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT
SO THAT THE CORRECT MATERIAL IS INSTALLED.
8 ALL FLOORING MATERIAL AND TRANSITIONS SHALL BE CENTERED UNDER THE DOOR IN
THE CLOSED POSITION UNLESS OTHERWISE NOTED.
9 EXTEND ALL FINISHES UNDER CABINETS, BENCHES, SHELVING, COUNTERTOPS AND
LAVATORIES.
10 ALL UNDER-COUNTER SUPPORT BRACKETS TO BE PAINTED TO MATCH ADJACENT WALL
COLOR.
11 CONTRACTOR SHALL BE RESPONSIBLE FOR ALLOWING FOR DELIVERY LEAD TIMES FOR
ALL FABRICS AND OTHER CUSTOM FINISHES WITHIN THE CONSTRUCTION SCHEDULE.
ALL DELIVERY TIMES MUST BE CONFIRMED, AND ANY EXCESSIVE LEAD TIME MUST BE
BROUGHT TO THE ARCHITECT'S ATTENTION IMMEDIATELY TO ALLOW FOR
RESPECIFICATION IF NECESSARY.
12 ALL COVER PLATES, SWITCHES, OUTLETS, RECEPTACLES AND DEVICES TO BE WHITE
UON.
13 OUTSIDE CORNERS TO RECEIVE CORNER GUARDS (U.O.N.).
14 PROVIDE (1) ROBE HOOK MOUNTED AT 5'-6" AFF AND (1) MOUNTED AT 4'-0" AFF AT EACH
TOILET ROOM DOOR. CENTER HOOK ON INSIDE OF DOOR.
15 REFER TO REFLECTED CEILING PLANS FOR SOFFIT AND CEILING MATERIALS AND
COLORS.
0'1'2'4'8'1/4" = 1'-0"A2 FIFTH FLOOR FINISH PLAN - SECTOR 1
#
REVISION SCHEDULE
NAME DATE
FLOOR FINISH LEGEND
Received by DiMarco 2/15/2021