Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A604 Borrowed Lites
CLEAR OPENING7' - 0"AFF2' - 6"OBSCURE GLASS PANEL - WF1 CLEAR OPENING6' - 10"AFF2' - 6"CLEAR OPENING 8' - 7" OBSCURE GLASS PANEL - WF1 C5 C5 A5 A5 CLEAR OPENING 9' - 0 1/2" EQ EQ EQ C5 C5 A5 A5 BL-LCLEAR OPENING6' - 4"AFF3' - 2"CLEAR OPENING 4' - 3" C5 C5 A5A5 BL-M BL-N OBSCURE GLASS PANEL - WF1 CLEAR OPENING3' - 8"AFF3' - 6"OBSCURE GLASS PANEL - WF1 CLEAR OPENING 8' - 6" EQ EQ EQ C5 C5 A5 A5 BL-JCLEAR OPENING6' - 0"AFF3' - 6"CLEAR OPENING 14' - 0" EQ EQ EQ EQ C5 C5 A5 BL-I A5 BL-HCLEAR OPENING5' - 10"AFF3' - 6"CLEAR OPENING 4' - 0" C1 C1 A1A1 OBSCURE GLASS PANEL - WF1 OBSCURE GLASS PANEL - WF1 BL-BCLEAR OPENING6' - 10"AFF2' - 6"2' - 8" C1 C1 A1 A1 OBSCURE GLASS PANEL - WF1 BL-ACLEAR OPENING6' - 10"AFF2' - 6"CLEAR OPENING 4' - 10" C1 C1 A1A1 OBSCURE GLASS PANEL - WF13' - 6" 1' - 4" GLAZED GLASS PANEL BL-GCLEAR OPENING6' - 10"AFF2' - 6"2' - 0" C5 C5 A5 A5 OBSCURE GLASS PANEL - WF1 BL-K2' - 0"AFF2' - 6"2' - 8" C5 C5 A5 A5 OBSCURE GLASS PANEL - WF1 CLEAR OPENING CLEAR OPENINGCLEAR OPENING CLEAR OPENINGCLEAR OPENING5' - 8"AFF3' - 8"CLEAR OPENING 5' - 0" BL-FCLEAR OPENING4' - 8"AFF2' - 6"2' - 0" C5 C5 A5A5 GLAZED GLASS PANEL CLEAR OPENING CLEAR OPENING7' - 4"AFF2' - 0"OBSCURE GLASS PANEL - WF1 CLEAR OPENING 9' - 0 1/2" C1 C1 BL-D CLEAR OPENING5' - 10"AFF3' - 6"OBSCURE GLASS PANEL - WF1 CLEAR OPENING 7' - 7" EQ EQ EQ C5 C5 A5 A5 BL-E CLEAR OPENING AFF9' - 6"CLEAR OPENING 11' - 0" EQ EQ EQ EQ C5 C5 A5 BL-O A5 OBSCURE GLASS PANEL - WF1 BL-CCLEAR OPENING6' - 10"AFF2' - 6"3' - 9" C1 C1 A1A1 OBSCURE GLASS PANEL - WF1 CLEAR OPENING CLEAR OPENING4' - 0"AFF2' - 10"CLEAR OPENING 4' - 0" C9 C9 A9A9 EQ EQ GLAZED GLASS PANEL BL-SG-CCLEAR OPENING6' - 10"AFF2' - 6"2' - 10" 2' - 2"4' - 0"1' - 8"5' - 2"1' - 8"BL-SG-BCLEAR OPENING5' - 8"AFF3' - 8"CLEAR OPENING 6' - 0" GLAZED GLASS PANEL CLEAR OPENING6' - 10"AFF2' - 6"3' - 0" 3' - 0"4' - 0"1' - 8"5' - 2"1' - 8"C9 C9 BL-SG-A A5A5 A9A9 C9 C9 C9 A5 A9 A5 A9 C9 GLAZED GLASS PANEL A11 BL-P4' - 0"AFF3' - 4"2' - 3" 3' - 0" 9" A11 A11 LEADED X-RAY SHIELD UNIT BY MFR 135 DEGREE ANGLE A11 FIXED FIXED FIXED 90 DEGREE ANGLE VARIES EQ EQ WALL CONSTRUCTION PONY WALL FRAMING SUPPORT CONNECTION TO FLOOR MODULAR X-RAY SHIELD PANEL LEAD SHIELDING, REFER TO FLOOR PLANS FOR WALL TYPE AND THICKNESS WOOD BLOCKING, AS REQUIRED 1/4" TEMPERED GLAZING, TYPICAL CLEAR BUMPERS, TYPICAL BOTH SIDES TYPESSEE PARTITIONCORNER BEAD, TYPICAL ALL EXPOSED CORNERSWOOD BLOCKING AS REQUIRED SHIM AS REQUIRED GYPSUM BOARD RETURN, TYPICAL TYPESSEE PARTITION2-1/2" BLACK FINISH ANODIZED ALUMINUM OVERHEAD TRACK, BASIS OF DESIGN CR LAURENCE SHARYN FRAMELESS PASS-THRU, FASTEN PER MANUFACTURER RECOMMENDATIONS 1/2" TEMPERED GLAZING 1-1/2" BLACK FINISH ANODIZED ALUMINUM DEEP CHANNEL, BASIS OF DESIGN CR LAURENCE CASCADE GLASS WALL, FASTEN PER MANUFACTURER RECOMMENDATIONS CONTINUOUS SEALANT ALL SIDES, TYPICAL GLAZING GASKET, PER MANUFACTURER RECOMMENDATIONS 1" BLACK FINISH ANODIZED ALUMINUM DEEP CHANNEL, BASIS OF DESIGN CR LAURENCE CASCADE GLASS WALL, FASTEN PER MANUFACTURER RECOMMENDATIONS NEOPRENE SETTING BLOCK, PER MANUFACTURER RECOMMENDATIONS CONTINUOUS BOX BEAM HEADER SEE REFLECTED CEILING PLAN FOR CEILING TYPE 2X2 BLACK FINISH ANODIZED ALUMINUM TUBE, BASIS OF DESIGN CR LAURENCE, MOUNT TO SIDE WALL WITH CONCEALED FASTENERS 1/4" TEMPERED GLAZING FIXED LITE SLIDING DOOR TYPES SEE PARTITION SURFACE APPLIED FIXED RAIL, PER MANUFACTURER SOLID SURFACE SILL OVER 3/4" PLYWOOD SURFACE APPLIED GUIDES, PER MANUFACTURER 1/2" TEMPERED GLAZING WITH APPLIED WINDOW FILM WF1 CLEAR COPOLYMER STRIP FOR 90 DEGREE ABUTMENT TO WALL, PER MANUFACTURER RECOMMENDATIONS TYPESSEE PARTITIONCORNER BEAD, TYPICAL ALL EXPOSED CORNERS WOOD BLOCKING AS REQUIRED SHIM AS REQUIRED GYPSUM BOARD RETURN, TYPICAL 1/2" TEMPERED GLAZING CLEAR COPOLYMER STRIP FOR 180 DEGREE GLASS-TO-GLASS JOINT, PER MANUFACTURER RECOMMENDATIONS LINE OF SOLID SURFACE SILL BELOW LINE OF SOLID SURFACE WATERFALL EDGE BELOW ALIGN EXPOSED EDGE OF TEMPERED GLAZING TO SOLID SURFACE EDGE BELOW 1/2" TEMPERED GLAZING WITH APPLIED WINDOW FILM WF1 1-1/2" BLACK FINISH ANODIZED ALUMINUM DEEP CHANNEL, BASIS OF DESIGN CR LAURENCE CASCADE GLASS WALL, FASTEN PER MANUFACTURER RECOMMENDATIONS CONTINUOUS SEALANT ALL SIDES, TYPICAL GLAZING GASKET, PER MANUFACTURER RECOMMENDATIONS CONTINUOUS BOX BEAM HEADER CONTINUOUS SEALANT ALL SIDES, TYPICAL GLAZING GASKET, PER MANUFACTURER RECOMMENDATIONS SHIM AS REQUIRED 1" BLACK FINISH ANODIZED ALUMINUM DEEP CHANNEL, BASIS OF DESIGN CR LAURENCE CASCADE GLASS WALL, FASTEN PER MANUFACTURER RECOMMENDATIONS NEOPRENE SETTING BLOCK, PER MANUFACTURER RECOMMENDATIONS SOLID SURFACE SILL OVER 3/4" PLYWOOD CONTINUOUS WOOD BLOCKING TYPES SEE PARTITION SEE REFLECTED CEILING PLAN FOR CEILING TYPE CLEAR COPOLYMER STRIP FOR 90 DEGREE ABUTMENT TO WALL, PER MANUFACTURER RECOMMENDATIONS TYPESSEE PARTITIONCORNER BEAD, TYPICAL ALL EXPOSED CORNERS WOOD BLOCKING AS REQUIRED SHIM AS REQUIRED GYPSUM BOARD RETURN, TYPICAL 1/2" TEMPERED GLAZING, SEE BORROWED LITE ELEVATION FOR GLAZING FINISH CLEAR COPOLYMER STRIP FOR 180 DEGREE OR 90 DEGREE GLASS-TO- GLASS JOINTS WHERE MULTIPLE PANELS OCCUR, PER MANUFACTURER RECOMMENDATIONS TYPESSEE PARTITION1/2" TEMPERED GLAZING WITH APPLIED WINDOW FILM WF1 1-1/2" BLACK FINISH ANODIZED ALUMINUM DEEP CHANNEL, BASIS OF DESIGN CR LAURENCE CASCADE GLASS WALL, FASTEN PER MANUFACTURER RECOMMENDATIONS CONTINUOUS SEALANT ALL SIDES, TYPICAL GLAZING GASKET, PER MANUFACTURER RECOMMENDATIONS CONTINUOUS BOX BEAM HEADER CONTINUOUS SEALANT ALL SIDES, TYPICAL GLAZING GASKET, PER MANUFACTURER RECOMMENDATIONS SHIM AS REQUIRED 1" BLACK FINISH ANODIZED ALUMINUM DEEP CHANNEL, BASIS OF DESIGN CR LAURENCE CASCADE GLASS WALL, FASTEN PER MANUFACTURER RECOMMENDATIONS NEOPRENE SETTING BLOCK, PER MANUFACTURER RECOMMENDATIONS CORNER BEAD, TYPICAL AT ALL EXPOSED CORNERS CONTINUOUS WOOD BLOCKING TYPES SEE PARTITION TYPES SEE PARTITION CORNER BEAD, TYPICAL AT ALL EXPOSED CORNERS SURFACE APPLIED GUIDES, PER MANUFACTURER WOOD BLOCKING AS REQUIRED TYPES SEE PARTITION 1/4" TEMPERED GLAZING TYPES SEE PARTITION CORNER BEAD, TYPICAL ALL EXPOSED CORNERS WOOD BLOCKING AS REQUIRED SHIM AS REQUIRED CONTINUOUS SEALANT ALL SIDES, TYPICAL GYPSUM BOARD RETURN, TYPICAL 2-1/2" BLACK FINISH ANODIZED ALUMINUM OVERHEAD TRACK, BASIS OF DESIGN CR LAURENCE SHARYN FRAMELESS PASS-THRU, FASTEN PER MANUFACTURER RECOMMENDATIONS FIXED LITE SLIDING DOOR SURFACE APPLIED FIXED RAIL, PER MANUFACTURERTYPESEE PARTITION2X2 BLACK FINISH ANODIZED ALUMINUM TUBE, BASIS OF DESIGN CR LAURENCE, MOUNT TO SIDE WALL WITH CONCEALED FASTENERS SUPPORT STUD FOR ALUMINUM TUBES TO FASTEN INTO, TYPICAL AT ALL LOCATIONS CONTINUOUS SEALANT ALL SIDES, TYPICAL DATE: PROJECT: OTHER: DRAWN BY: A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 11 12 H I 11 12 H I 619 West State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration.2/5/2021 4:55:35 PMA604 BORROWED LITES 02/05/2021 2018089 JDC/HRT/KAS Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3" = 1'-0"A11 LEAD LINED HM WINDOW HEAD / JAMB / SILL DETAIL 3" = 1'-0"A9 TRANSACTION WINDOW JAMB DETAIL 3" = 1'-0"C9 CHECK-IN TRANSACTION WINDOW HEAD/SILL DETAIL 3" = 1'-0"A1 CHECK-IN BORROWED LITE JAMB DETAIL 3" = 1'-0"C1 CHECK-IN BORROWED LITE HEAD/SILL DETAIL 3" = 1'-0"A5 BORROWED LITE JAMB DETAIL 3" = 1'-0"C5 BORROWED LITE HEAD/SILL DETAIL REVISION SCHEDULE NAME DATE 3" = 1'-0"C11 TRANSACTION WINDOW HEAD/SILL DETAIL 3" = 1'-0"D7 ALUMINUM HEADER JAMB SUPPORT DETAIL Received by DiMarco 2/15/2021