HomeMy WebLinkAboutA562 Enlarged Plans Elevations & SectionsEWS-12' - 3 1/2"3' - 2"1B
1B 1' - 3"3 3 °
2' - 1
1
"
LINE OF
WALL BELOW
SOLID SURFACE
TRANSACTION
COUNTER
COUNTER
SUPPORT
BRACKETS @
3'-0" O.C. MAX
SOLID SURFACE
COUNTER
1 0 1 /4"A6
A562
________________________________________________
A10
A562
________________________________________________
SOLID SURFACE
RETURN, SOFT
EDGE ON ALL
OUTSIDE EDGES,
TYP
2' - 8 1/2"3' - 1 3/4"2' - 9 1/4"
52°
3' - 3"6' - 0"2' - 0"G11
A562
________________________________________________3' - 0"SOLID SURFACE BENCH
LINE OF P-LAM FACE BELOW
ALIGN P-LAM FACE TO
WALL, NO TOE KICK
AT THIS SIDE
2" RADIUS AT CORNERS
11' - 5 3/8"
4 ' - 8 1 /4 "9 1 /8 "VERIFY ALL DIMENSIONS IN
FIELD PRIOR TO FABRICATION
1 ' - 8 1 /2 "D11
A562
________________________________________________
A562
A1
C8
A562
________________________________________________
1
' -
1
0
5
/8"2' - 6"1' -
5 7/8"6' - 1
3
/4"2'
- 2 7/
8
"
1
' -
1
0
3
/8"
2 ' - 0 5 /8 "2 ' - 2 3 /4 "3 ' - 1 1 7 /8 "1' - 6" R12
'
-
0
"
8 ' - 3 1 /8 "13' - 8" R
4' - 0" R
12
' -
0
1/
4
"
10' - 0 3/4" R
8 ' - 9 7 /8 "1B
1B
TOP OF WALL
CAP @ 24" AFF
1B
BL-D
SOILID SURFACE WITH
BULLNOSE EDGE
2"4"1' - 6"WALL BASE AS
SCHEDULED, TYP.
(3) BUILT-UP 1/4"
BENDABLE PLYS FACED
WITH PLASTIC LAMINATE
FIXED PANEL
VARIES
2 3/4"
SEALANT
101BA
1B
1B
1B
1B
BL-SG-C
1 1 3 /4 "3 ' - 5 1 /4 "1' - 0 1/4"
2' - 0" 1' - 0"1' - 0"3' - 9 3/4"3 ' - 2 1 /4 "
3 ' - 1 1 1 /4 "2'
- 0 1/4"1'
- 0"8"1' - 8"3 ' - 8 "
4' - 8"
A L IG N
103°
103°1'
- 1 3/4"5 1/2"2' - 1"DAYGATE
101B
RECEPTION
101
LOBBY/WAITING
ALUMINUM
COLUMN
COVER
COUNTER
SUPPORT
BRACKETS @
3'-0" O.C. MAX
LINE OF WALL
BELOW
D10
A565
________________________________________________
6' - 0"7' - 10"2' - 0"1' - 0"10"10"8' - 8 1/4"102°A3
A562
________________________________________________
SOLID SURFACE BENCH
WITH SOFT EDGE ON ALL
OUTSIDE EDGES, TYP
1' - 2 1/2"3' - 9"2' - 1 1/4"1' - 4"3' - 5"3' - 10 1/4"
FIRST FLOOR
100' -0"
3/4" MARINE GRADE
PLYWOOD
FLUID APPLIED
WATERPROOFING BARRIER.
APPLY TO ENTIRE INNER
SURFACE OF PLYWOOD
PLANTER BOX AS SHOWN.
BASIS OF DESIGN GACOFLEX
LM60 SYSTEM BY GACO
PROVIDE A REMOVABLE
GALVANIZED METAL
PLANTER BOX, CUSTOM
FIT FOR PLANTER AREA 3"1/4"1' - 0"5/8" MARINE PLYWOOD
SOLID SURFACE STOOL
WITH SOFT EDGES AT ALL
OUTSIDE CORNERS, TYP
STIFFCLIP CL ANCHOR
@ 16"OC (OR
APPROVED EQUAL)
2X8 WOOD
BLOCKING AT 12" OC
PARTITION TYPE AS
SCHEDULED
3/4" MARINE GRADE
PLYWOOD
FLUID APPLIED
WATERPROOFING
BARRIER. APPLY TO
ENTIRE INNER SURFACE
OF PLYWOOD PLANTER
BOX AS SHOWN. BASIS
OF DESIGN GACOFLEX
LM60 SYSTEM BY GACO
PROVIDE A
REMOVABLE
GALVANIZED METAL
PLANTER BOX,
CUSTOM FIT FOR
PLANTER AREA
SOLID SURFACE STOOL
WITH SOFT EDGES AT ALL
OUTSIDE CORNERS, TYP
STIFFCLIP CL ANCHOR
@ 16"OC (OR
APPROVED EQUAL)
2X8 WOOD
BLOCKING AT 12" OC 2' - 0"1/2" TEMPERED
GLAZING WITH
WINDOW FILM (WF1)3"1' - 0"CONTINUOUS SEALANT ALL
SIDES, TYPICAL
GLAZING GASKET, PER MANUFACTURER
RECOMMENDATIONS
SHIM AS REQUIRED
1" BLACK FINISH ANODIZED ALUMINUM
DEEP CHANNEL, BASIS OF DESIGN CR
LAURENCE CASCADE GLASS WALL,
FASTEN PER MANUFACTURER
RECOMMENDATIONS
CONTINUOUS WOOD BLOCKING
1-1/2" BLACK FINISH ANODIZED
ALUMINUM DEEP CHANNEL, BASIS OF
DESIGN CR LAURENCE CASCADE
GLASS WALL, FASTEN PER
MANUFACTURER RECOMMENDATIONS
GLAZING GASKET, PER MANUFACTURER
RECOMMENDATIONS
CONTINUOUS BOX BEAM
HEADER
CONTINUOUS SEALANT ALL
SIDES, TYPICAL
OPEN CORNER FOR WIRE
MANAGEMENT
SUPPORT BRACKET
STIFFCLIP CL ANCHOR @ 16" OC
(OR APPROVED EQUAL)
PROVIDE PATHWAYS FOR
FUTURE ELECTRICAL/DATA RUNS
A552
G1
8"2' - 11"2' - 6"SOFT EDGE ON ALL
OUTSIDE EDGES, TYP
SOLID SURFACE
COUNTERTOP, RETURN
SOLID SURFACE AT ENDS
2"
WALL PROTECTION
CONTINUOUS BASE
SOLID SURFACE ON 3/4"
PLYWOOD BLOCKING
WALL BASE AS SCHEDULED
1' - 3"
1' - 11 1/2"
LED LIGHT TAPE
3 3/8"8 1/2"7 1/2"1 1/2"3" DIAMETER GROMMET,
MINIMUM ONE (1) PER 3' -0"
OC, COORDINATE LOCATIONS
WITH OWNER
3/4" CORE
SOLID SURFACE
COUNTERTOP, RETURN
SOLID SURFACE AT ENDS
SOFT EDGE ON ALL
OUTSIDE EDGES, TYP
TACKABLE PANEL
CONTINUOUS BASE
2"
PROVIDE PATHWAYS FOR
FUTURE ELECTRICAL/DATA RUNS
OPEN CORNER FOR WIRE
MANAGEMENT
2X4 WOOD BLOCKING
AT 12" OC
SUPPORT BRACKET
STIFFCLIP CL ANCHOR @ 16" OC
(OR APPROVED EQUAL) 2' - 6"3' - 6"2"
A552
G1
A552
G1
3' - 2 1/2"
2' - 11"
WALL PROTECTION
SOLID SURFACE
ON 3/4" PLYWOOD
BLOCKING
WALL BASE AS
SCHEDULED
D11
A562
________________________________________________
1/2" TEMPERED
GLAZING WITH
WF1
2' - 0"CONTINUOUS BASE
SOLID SURFACE CAP7' - 4"3"BL-D
5/8" PLYWOOD
FLUID APPLIED
WATERPROOFING
BARRIER. APPLY TO
ENTIRE INNER SURFACE
OF PLYWOOD PLANTER
BOX AS SHOWN. BASIS
OF DESIGN GACOFLEX
LM60 SYSTEM BY GACO
PROVIDE A REMOVABLE
GALVANIZED METAL
PLANTER BOX, CUSTOM
FIT FOR PLANTER AREA 3"11 1/4"2X4 WOOD
BLOCKING AT 12" OC
SOLID SURFACE BENCH
WITH SOFT EDGE ON
ALL OUTSIDE EDGES,
TYP
WALL BASE AS
SCHEDULED, TYP.
3/4" PLYWOOD
3 5/8"8"1' - 7"VARIES
DATE:
PROJECT:
OTHER:
DRAWN BY:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Architecture
Planning
Interior Design
11 12
H
I
11 12
H
I
619 West State Street
Ithaca, New York 14850
132 E. Jefferson Street
Syracuse, New York 13202
p 607 273 7600 www.holt.com
WARNING: It is a violation of New
York State Law for any person,
unless acting under the direction of
a licensed Architect, to alter this
document in any way. If a document
bearing the seal of an Architect is
altered, the altering Architect shall
affix to such document his seal and
the notation "altered by" followed by
his signature, the date of such
alteration, and a specific description
of the alteration.2/5/2021 4:54:48 PMA562
ENLARGED
PLANS,
ELEVATIONS
AND SECTIONS
02/05/2021
2018089
KAS Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1/2" = 1'-0"G1 ENLARGED PLAN - MAIN LOBBY 100 RECEPTION DESK
1/2" = 1'-0"G8 LOBBY/ WAITING 101 MILLWORK BENCH ENLARGED PLAN
1/2" = 1'-0"C4 LOBBY/WAITING 101 - ENLARGED PLANTER PLAN
1 1/2" = 1'-0"G11 DETAIL - SOLID SURFACE BENCH WITH P-LAM FACE
1/2" = 1'-0"C1 RECEPTION 101B ENLARGED PLAN
1/2" = 1'-0"G4 ENLARGED PLAN - MAIN LOBBY 100 STAIR PLANTER/BENCH
1 1/2" = 1'-0"C8 DETAIL - LOBBY/WAITING 101 PLANTER AT WINDOW
1 1/2" = 1'-0"D11 DETAIL - LOBBY/WAITING 101 PLANTER AT PANEL
1 1/2" = 1'-0"A10 DETAIL - SECTION @ MAIN LOBBY 100 DESK - COUNTER
1 1/2" = 1'-0"A6 DETAIL - SECTION @ MAIN LOBBY 100 DESK - TRANSACTION
1/2" = 1'-0"A1 LOBBY/WAITING 101 - ENLARGED PLANTER/PANEL ELEVATION
1 1/2" = 1'-0"A3 DETAIL - SECTION @ MAIN LOBBY 100 PLANTER/ BENCH
REVISION SCHEDULE
NAME DATE
Received by DiMarco 2/15/2021