Loading...
HomeMy WebLinkAboutA503 Exterior DetailsFINISHED FLOOR EWS-34AECW-1EWS-3 EWS-2FS-1EWS-3 ECW-1 4A ECW-1 EWS-3 ECW-1 2B5A 4C ECW-1 3A3AEWS -2 EWS-34 A 4AEWS-2EW S -2 ECW-1CS-1CS-1EWS-1EWS-1CW-1 EWS-3 1 CURTAIN WALL MULLION CURTAIN WALL MULLION STEEL BEAM, REFER TO STRUCTURAL DRAWINGS CURTAIN WALL BRACKET ALUMINUM TRIM FRY REGLET CORNER TRIM DMCT-1250; CLEAR ANODIZED FINISH ALIGN TUBE COLUMN ENCLOSURE BEYOND ALIGN ALUMINUM TRIM FRY REGLET CORNER TRIM DMCT-1250; CLEAR ANODIZED FINISH ALUMINUM BACKPAN TO MATCH CURTAIN WALL FINISH 2 1/2" CFMF @ 16" OC BACKER ROD AND SEALANT MINERAL WOOD BOARD INSULATION 5/8" GYPSUM BOARD, TYPICAL PROVIDE FINISHED 5/8" GYPSUM BOARD WHERE BACK SIDE OF TUBE IS EXPOSED. BACK ROD AND SEALANT 168° PREFINISHED ALUMINUM BREAK METAL TO MATCH CURTAIN WALL FINISH BACK ROD AND SEALANT CONTINUOUS SEALANT MINERAL-WOOL BATT INSULATION BREAK METAL FILLER TO MATCH CURTAIN WALL WOOD BLOCKING THERMAL ISOLATION MATERIAL BACK ROD AND SEALANT EXTEND AIR BARRIER SYSTEM AROUND CURTAIN WALL SUPPORT BENT PLATE D SEALANT SOLID SURFACE PLYWOOD BACKING PANEL A503 E1 SEALANT WOOD BLOCKING 9"WINDOW ROLLER SHADES WHERE SCHEDULED ACOUSTICAL PANEL CEILING 1 FR SEALANTEQEQOF MULLION FINISH AND PAINT END OF WALL EDGE OF SLAB, BELOW ALUMINUM TRIM AT FLOOR BELOW 2 1/2" 1 C ALIGN EXTEND AIR BARRIER SYSTEM INTO ROUGH OPENING AND SEAL CURTAIN WALL TEE ANCHOR BACK ROD AND SEALANT WOOD BLOCKING WEATHER BARRIER CONTINUOUS VAPOR-PERMEABLE AIR BARRIER SYSTEM CLOSED-CELL SPRAY APPLIED FOAM INSULATION CONTINUOUS VAPOR-PERMEABLE AIR BARRIER SYSTEM WEATHER BARRIER BACKER ROD AND SEALANT BOTH SIDES WOOD BLOCKING SEAL AIR BARRIER SYSTEM TO CURTAIN WALL 3.8 WEATHER BARRIER CONTINUOUS VAPOR-PERMEABLE AIR BARRIER SYSTEMBACK ROD AND SEALANT EXTEND AIR BARRIER SYSTEM INTO ROUGH OPENING AND SEAL WOOD BLOCKING ALIGN, CURTAIN WALL AND FACE OF GYPSUM BOARD 1' - 5 5/8"1' - 2" +/- TYP 1/2"1 1/2"2 3/4"1/2"3"PERFORATED ANODIZED ALUMINUM METAL GRATING, BASIS OF DESIGN MCNICHOLS ROUND, ALUMINUM, 20 GAUGE ROUND HOLES ON STAGGERED CENTERS, 51% OPEN AREA OR EQUAL BRUSHED ALUMINUM CHANNEL TRIM. BASIS OF DESIGN FRY REGLET J MOLDING OR EQUAL. CONTINUOUS CLEAR SEALANT BELOW SILL WALL BASE, SEE FINISH SCHEDULE SEALANT, ENTIRE PERIMETER 1/4"WALL PROTECTION OR RUB RAIL AS INDICATED ON FINISH PLANS. PROVIDE CONTINUOUS SEALANT JOINT AT ALL TRIM INTERSECTIONS 1' - 0" TYPICALPERFORATED ANODIZED ALUMINUM METAL GRATING, BASIS OF DESIGN MCNICHOLS ROUND, ALUMINUM, 20 GAUGE ROUND HOLES ON STAGGERED CENTERS, 51% OPEN AREA OR EQUAL BRUSHED ALUMINUM CHANNEL TRIM. BASIS OF DESIGN FRY REGLET J MOLDING OR EQUAL. NOTE: OMIT BASE CAVITY OPENING AT PLANTER LOCATIONS. THIS DETAIL ONLY APPLIES TO WINDOW OPENINGS ON FLOORS 3, 4 AND 5 D T/O CURTAIN WALL 176' -4" RUN AIR BARRIER INTO ROUGH OPENING AND SEAL TO CURTAIN WALL BACK ROD AND SEALANT WOOD BLOCKING, AS REQUIRED CURTAIN WALL TEE ANCHOR SEE STRUCTURAL FOR ANGLE SUPPORT @ 6'-0" OC TO ALIGN WITH CURTAIN WALL VERTICAL MULLIONS ALUMINUM VENT TURN AIR BARRIER SYSTEM INTO VENT, SEAL EDGES 4" 1 EXTEND AIR BARRIER SYSTEM INTO ROUGH OPENING AND SEAL CURTAIN WALL CURTAIN WALL TEE ANCHOR FIRE RETARDANT WOOD BLOCKING BACKER ROD AND SEALANT SEAL WEATHER BARRIER TO AIR BARRIER CLOSED-CELL SPRAY APPLIED FOAM INSULATION CONTINUOUS ALUMINUM TRIM WITH HEMMED EDGE TO MATCH CURTAIN WALL THIRD FLOOR 128' -6" 1 SLOPE 1/4" : 12" A502 A5 A503 C8 ALIGN DATE: PROJECT: OTHER: DRAWN BY: A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 11 12 H I 11 12 H I 619 West State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration.2/5/2021 4:54:23 PMA503 EXTERIOR DETAILS 02/05/2021 2018089 CRB, KAS Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3" = 1'-0"F10 CURTAIN WALL DETAIL @ BALCONY 1 1/2" = 1'-0"A11 CURTAIN WALL ANGLED MULLION 1 1/2" = 1'-0"A9 CURTAIN WALL BASE @ METAL PANEL - TYPICAL 1 1/2" = 1'-0"C8 CURTAINWALL STOOL 1 1/2" = 1'-0"E8 CURTAIN WALL HEAD/JAMB DETAIL @ WINDOW - TYPICAL 1 1/2" = 1'-0"D6 CURTAIN WALL MULLION - PLAN DETAIL 1 1/2" = 1'-0"E6 CURTAIN WALL - PLAN DETAIL 1 1/2" = 1'-0"A7 CURTAIN WALL JAMB DETAIL 1 1/2" = 1'-0"A5 CURTAIN WALL JAMB DETAIL 6" = 1'-0"E1 EXTERIOR WALL - PASSIVE CAVITY CONVECTION DETAIL AT WINDOWS 1 1/2" = 1'-0"G8 CURTAIN WALL HEAD DETAIL - TYPICAL, UNO (SIMILAR @ JAMB) 1 1/2" = 1'-0"G6 CURTAIN WALL HEAD DETAIL 1 1/2" = 1'-0"A2 CURTAIN WALL DETAIL@ BASE REVISION SCHEDULE NAME DATE Received by DiMarco 2/15/2021