HomeMy WebLinkAboutA503 Exterior DetailsFINISHED FLOOR
EWS-34AECW-1EWS-3
EWS-2FS-1EWS-3
ECW-1
4A
ECW-1
EWS-3
ECW-1 2B5A
4C
ECW-1 3A3AEWS -2 EWS-34 A
4AEWS-2EW S -2
ECW-1CS-1CS-1EWS-1EWS-1CW-1
EWS-3
1
CURTAIN WALL MULLION
CURTAIN WALL MULLION
STEEL BEAM, REFER TO
STRUCTURAL DRAWINGS
CURTAIN WALL BRACKET
ALUMINUM TRIM
FRY REGLET CORNER TRIM
DMCT-1250; CLEAR
ANODIZED FINISH
ALIGN
TUBE COLUMN
ENCLOSURE BEYOND
ALIGN
ALUMINUM TRIM
FRY REGLET CORNER TRIM
DMCT-1250; CLEAR
ANODIZED FINISH
ALUMINUM BACKPAN TO
MATCH CURTAIN WALL FINISH
2 1/2" CFMF @ 16" OC
BACKER ROD
AND SEALANT
MINERAL WOOD BOARD
INSULATION
5/8" GYPSUM
BOARD, TYPICAL
PROVIDE FINISHED
5/8" GYPSUM
BOARD WHERE
BACK SIDE OF
TUBE IS EXPOSED.
BACK ROD AND SEALANT
168°
PREFINISHED ALUMINUM
BREAK METAL TO MATCH
CURTAIN WALL FINISH
BACK ROD AND SEALANT
CONTINUOUS SEALANT
MINERAL-WOOL BATT
INSULATION
BREAK METAL FILLER TO
MATCH CURTAIN WALL
WOOD BLOCKING
THERMAL ISOLATION
MATERIAL
BACK ROD AND SEALANT
EXTEND AIR BARRIER
SYSTEM AROUND CURTAIN
WALL SUPPORT
BENT PLATE
D
SEALANT
SOLID SURFACE
PLYWOOD
BACKING PANEL
A503
E1
SEALANT
WOOD BLOCKING 9"WINDOW ROLLER
SHADES WHERE
SCHEDULED
ACOUSTICAL
PANEL CEILING
1
FR SEALANTEQEQOF MULLION
FINISH AND
PAINT END
OF WALL
EDGE OF SLAB,
BELOW
ALUMINUM TRIM
AT FLOOR BELOW
2 1/2"
1
C
ALIGN
EXTEND AIR BARRIER
SYSTEM INTO ROUGH
OPENING AND SEAL
CURTAIN WALL TEE ANCHOR
BACK ROD AND SEALANT
WOOD BLOCKING
WEATHER BARRIER
CONTINUOUS
VAPOR-PERMEABLE AIR
BARRIER SYSTEM
CLOSED-CELL SPRAY
APPLIED FOAM INSULATION
CONTINUOUS
VAPOR-PERMEABLE AIR
BARRIER SYSTEM
WEATHER BARRIER
BACKER ROD AND SEALANT
BOTH SIDES
WOOD BLOCKING
SEAL AIR BARRIER SYSTEM
TO CURTAIN WALL
3.8
WEATHER BARRIER
CONTINUOUS
VAPOR-PERMEABLE AIR
BARRIER SYSTEMBACK ROD AND SEALANT
EXTEND AIR BARRIER
SYSTEM INTO ROUGH
OPENING AND SEAL
WOOD BLOCKING
ALIGN, CURTAIN WALL
AND FACE OF
GYPSUM BOARD 1' - 5 5/8"1' - 2" +/-
TYP
1/2"1 1/2"2 3/4"1/2"3"PERFORATED ANODIZED
ALUMINUM METAL GRATING, BASIS
OF DESIGN MCNICHOLS ROUND,
ALUMINUM, 20 GAUGE ROUND
HOLES ON STAGGERED CENTERS,
51% OPEN AREA OR EQUAL
BRUSHED ALUMINUM
CHANNEL TRIM. BASIS OF
DESIGN FRY REGLET J
MOLDING OR EQUAL.
CONTINUOUS CLEAR SEALANT
BELOW SILL
WALL BASE, SEE FINISH
SCHEDULE
SEALANT, ENTIRE
PERIMETER 1/4"WALL PROTECTION OR
RUB RAIL AS INDICATED
ON FINISH PLANS.
PROVIDE CONTINUOUS
SEALANT JOINT AT ALL
TRIM INTERSECTIONS
1' - 0" TYPICALPERFORATED ANODIZED
ALUMINUM METAL GRATING, BASIS
OF DESIGN MCNICHOLS ROUND,
ALUMINUM, 20 GAUGE ROUND
HOLES ON STAGGERED CENTERS,
51% OPEN AREA OR EQUAL
BRUSHED ALUMINUM
CHANNEL TRIM. BASIS OF
DESIGN FRY REGLET J
MOLDING OR EQUAL.
NOTE: OMIT BASE CAVITY
OPENING AT PLANTER
LOCATIONS. THIS DETAIL ONLY
APPLIES TO WINDOW OPENINGS
ON FLOORS 3, 4 AND 5
D
T/O CURTAIN WALL
176' -4"
RUN AIR BARRIER INTO
ROUGH OPENING AND
SEAL TO CURTAIN WALL
BACK ROD AND SEALANT
WOOD BLOCKING, AS
REQUIRED
CURTAIN WALL
TEE ANCHOR
SEE STRUCTURAL FOR ANGLE
SUPPORT @ 6'-0" OC TO ALIGN
WITH CURTAIN WALL VERTICAL
MULLIONS
ALUMINUM VENT
TURN AIR BARRIER SYSTEM
INTO VENT, SEAL EDGES
4"
1
EXTEND AIR BARRIER
SYSTEM INTO ROUGH
OPENING AND SEAL
CURTAIN WALL
CURTAIN WALL
TEE ANCHOR
FIRE RETARDANT
WOOD BLOCKING
BACKER ROD
AND SEALANT
SEAL WEATHER
BARRIER TO AIR
BARRIER
CLOSED-CELL SPRAY
APPLIED FOAM INSULATION
CONTINUOUS
ALUMINUM TRIM WITH
HEMMED EDGE TO
MATCH CURTAIN WALL
THIRD FLOOR
128' -6"
1
SLOPE 1/4" : 12"
A502
A5
A503
C8
ALIGN
DATE:
PROJECT:
OTHER:
DRAWN BY:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Architecture
Planning
Interior Design
11 12
H
I
11 12
H
I
619 West State Street
Ithaca, New York 14850
132 E. Jefferson Street
Syracuse, New York 13202
p 607 273 7600 www.holt.com
WARNING: It is a violation of New
York State Law for any person,
unless acting under the direction of
a licensed Architect, to alter this
document in any way. If a document
bearing the seal of an Architect is
altered, the altering Architect shall
affix to such document his seal and
the notation "altered by" followed by
his signature, the date of such
alteration, and a specific description
of the alteration.2/5/2021 4:54:23 PMA503
EXTERIOR
DETAILS
02/05/2021
2018089
CRB, KAS Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3" = 1'-0"F10 CURTAIN WALL DETAIL @ BALCONY
1 1/2" = 1'-0"A11 CURTAIN WALL ANGLED MULLION
1 1/2" = 1'-0"A9 CURTAIN WALL BASE @ METAL PANEL - TYPICAL
1 1/2" = 1'-0"C8 CURTAINWALL STOOL
1 1/2" = 1'-0"E8 CURTAIN WALL HEAD/JAMB DETAIL @ WINDOW - TYPICAL
1 1/2" = 1'-0"D6 CURTAIN WALL MULLION - PLAN DETAIL
1 1/2" = 1'-0"E6 CURTAIN WALL - PLAN DETAIL
1 1/2" = 1'-0"A7 CURTAIN WALL JAMB DETAIL
1 1/2" = 1'-0"A5 CURTAIN WALL JAMB DETAIL
6" = 1'-0"E1 EXTERIOR WALL - PASSIVE CAVITY CONVECTION DETAIL AT WINDOWS
1 1/2" = 1'-0"G8 CURTAIN WALL HEAD DETAIL - TYPICAL, UNO (SIMILAR @ JAMB)
1 1/2" = 1'-0"G6 CURTAIN WALL HEAD DETAIL
1 1/2" = 1'-0"A2 CURTAIN WALL DETAIL@ BASE
REVISION SCHEDULE
NAME DATE
Received by DiMarco 2/15/2021