Loading...
HomeMy WebLinkAboutA502 Exterior DetailsRS-2RS-1EWS-3 EWS-2 RS-1RS-1FS-1EWS-2 RS-2RS-2EWS-1SIM EWS-3EWS-3SIMEWS-3CS-1EWS-2 EWS-1FS-1ECW-1 EWS-2CS-1EWS-2 EWS-1 FS-1PRE-FORMED SEAMLESS PIPE FLASHING BOOT VENT PIPE OR STRUCTURAL SUPPORT ROOF SYSTEM STANDARD JOINT SEALANT STAINLESS STEEL CLAMPING RING WATER CUT-OFF MASTIC ROOF SYSTEM 2'-0" TAPER 1/2" PER FOOT ROOF MEMBRANE ROOF DRAIN ROOF MEMBRANE ROOF SYSTEM STANDARD JOINT SEALANT ROOF SYSTEM PROVIDE GRAVEL GUARD AT RS-2 MINIMUM1' - 0"ROOF SYSTEM STANDARD JOINT SEALANT ROOF SYSTEM ROOF SYSTEM FLASHING MEMBRANE EQUIPMENT CURB AND INTEGRAL CAP FLASHING MECHANICAL EQUIPMENT ROOF MEMBRANE ROOF HATCH ROOF CURB BLOCKING AS REQUIRED SEE STRUCTURAL DRAWINGS FOR ROOF OPENING FRAMING 5/8" GYPSUM BOARD ON METAL FRAMING 5/8" GYPSUM BOARD ON METAL FRAMING CANT FULLY ADHERED MEMBRANE ROOFING GLASS-MAT GYPSUM SHEATHING CANT SIM FULLY ADHERED MEMBRANE ROOFING EXTEND VAPOR RETARDER UP SHEATHING TO TOP OF CANT WOOD BLOCKING, AS REQUIRED FULLY ADHERED MEMBRANE ROOFINGEXTEND ROOF MEMBRANE DOWN FACE, AND MECHANICALLY FASTEN TO BLOCKING JOIN AIR BARRIER SYSTEM OF WALL TO AIR BARRIER SYSTEM OF ROOF WITH TRANSITION FLASHING CONTINUOUS VAPOR-PERMEABLE AIR BARRIER SYSTEM SEE STRUCTURAL DRAWINGS FOR STAIR ROOF FRAMING METAL FASCIA ALUMINUM FLASHING WITH DRIP TO MATCH METAL COMPOSITE PANELS CONTINUOUS SEALANT ENTIRE PERIMETER OF DOOR FRAME LAP WEATHER BARRIER UNDER AND OVER FLASHING ALUMINUM GUTTER SLOPE, 1/4"/FT FLASHING CANT THERMALLY BROKEN EXTERIOR THRESHOLD CONTINUOUS SEALANT ALUMINUM SUB SILL EXTEND ROOF MEMBRANE UP OVER BLOCKING AND UNDER THRESHOLD BENT PLATE THERMAL ISOLATION MATERIAL MEMBRANE FLASHING 1' - 0"STAINLESS STEEL COUNTER FLASHING WITH MIN 1/2" DRIP FULLY ADHERED MEMBRANE ROOFING CANT ROOFING MANUFACTURER'S STANDARD TERMINATION B/O LOW ROOF DECK 124' -6" T/O LOW ROOF PARAPET 125' -11"6 1/2"CONTINUOUS VAPOR-IMPERMEABLE AIR BARRIER SYSTEM EXTEND ROOF MEMBRANE DOWN FACE, AND MECHANICALLY FASTEN TO BLOCKING JOIN AIR BARRIER SYSTEM OF WALL TO AIR BARRIER SYSTEM OF ROOF WITH TRANSITION FLASHING METAL FASCIA CANT WOOD BLOCKING, AS REQUIRED W FULLY ADHERED MEMBRANE ROOFING WEEP/VENT 24" OC D PLYWOOD SHEATHING EXTEND MEMBRANE ROOFING DOWN THE EXTERIOR FACE OF PARAPET AND JOIN AIR BARRIER SYSTEM OF WALL WITH TRANSITION FLASHING SEAL AIR BARRIER SYSTEM TO CURTAIN WALL T/O CURTAIN WALL 176' -4" METAL FASCIA6"5"3"1' - 4" CFMF TRUSS, SEE STRUCTURAL DRAWINGS SEE STRUCTURAL DRAWINGS FOR TRUSS BEARING AND BRACES COMPOSITE METAL PANEL RAINSCREEN SEE STRUCTURAL DRAWINGS FOR TRUSS BEARING WITHOUT COVER BOARD AND ROOF MEMBRANEA502 A9 SIM CONTINUOUS VAPOR-PERMEABLE AIR BARRIER SYSTEM PLYWOOD SHEATHING PLYWOOD SHEATHING FULLY ADHERED MEMBRANE ROOFING SEE STRUCTURAL DRAWINGS FOR THERMAL BREAK, LOCATE WITHIN ROOF INSULATION 7' - 0" FULLY ADHERED MEMBRANE ROOFING FILL WITH CLOSED-CELL INSULATION, TYPICAL A503 G8 SEE STRUCTURAL FOR ANGLE SUPPORT @ 6'-0" OC TO ALIGN WITH CURTAIN WALL VERTICAL MULLIONS FIRESTOP SEALANT FIRESAFING INSULATION 3" CONTINUOUS LINEAR ALUMINUM SOFFIT VENT NOTE: OMIT VENT AT AREAS OF RATED CONSTRUCTION; SEE ROOF CODE CONFORMANCE PLAN 3" CONTINUOUS LINEAR ALUMINUM SOFFIT VENT NOTE: OMIT VENT AT AREAS OF RATED CONSTRUCTION; SEE ROOF CODE CONFORMANCE PLAN TO MATCH METAL COMPOSITE PANEL RAINSCREEN SYSTEM WOOD BLOCKING, AS REQUIRED NOTE: FR BLOCKING AT AREAS OF RATED CONSTRUCTION; SEE ROOF CODE CONFORMANCE PLAN 5/8" GYPSUM BOARD PROVIDE AT AREAS OF RATED CONSTRUCTION; SEE ROOF CODE CONFORMANCE PLAN 5/8" GLASS-MAT GYPSUM SHEATHING IN LIEU OF PLYWOOD PROVIDE AT AREAS OF RATED CONSTRUCTION; SEE ROOF CODE CONFORMANCE PLANMETAL FRAMING OR FR WOOD BLOCKING, AT PANEL JOINTS AT AREAS OF RATED CONSTRUCTION; SEE ROOF CODE CONFORMANCE PLAN THIRD FLOOR 128' -6" 1 WEATHER BARRIER A501 H5 4" LEG AIR BARRIER STRIP AT CORNER TO OVERLAP HORIZONTAL AND VERTICAL AIR BARRIER SYSTEM, TYP JOIN AIR BARRIER SYSTEM OF HORIZONTAL WALL TO AIR BARRIER SYSTEM OF VERTICAL WALL SLOPE 1/4" : 12" BACK ROD AND SEALANT 8"EXTEND AIR BARRIER INTO ROUGH OPENING AND SEAL TO CURTAIN WALL AND FLASHING ALUMINUM FLASHING WITH DRIP TO MATCH METAL COMPOSITE MATERIAL WALL PANELS (MCP-1) SINGLE-PIECE MULLION COVER THERMAL ISOLATION MATERIAL SEAL WEATHER BARRIER TO AIR BARRIER FIRESTOP SEALANT ALUMINUM TRIM FIRESAFING INSULATION WEEP & BAFFLE THIRD FLOOR 128' -6" 1 A501 H5 WEATHER BARRIER CONTINUOUS VAPOR-PERMEABLE AIR BARRIER SYSTEM WEEP & BAFFLE DATE: PROJECT: OTHER: DRAWN BY: A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 11 12 H I 11 12 H I 619 West State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration.2/10/2021 2:36:49 PMA502 EXTERIOR DETAILS 02/05/2021 2018089 CRB, GLM Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1 1/2" = 1'-0"A7 TYPICAL ROOF PENETRATION 1 1/2" = 1'-0"E7 ROOF DRAIN 1 1/2" = 1'-0"A11 EQUIPMENT CURB DETAIL 1 1/2" = 1'-0"F11 ROOF HATCH 1 1/2" = 1'-0"A9 ROOF CANT - TYPICAL 1 1/2" = 1'-0"D11 DOOR HEAD @ STAIR 2 ROOF 1 1/2" = 1'-0"B11 DOOR THRESHOLD @ STAIR 2 ROOF 1 1/2" = 1'-0"B9 ROOF BASE FLASHING @ METAL PANEL 1 1/2" = 1'-0"E9 FASCIA @ BRICK - TYPICAL 1 1/2" = 1'-0"E1 ROOF DETAIL @ TOP OF CURTAINWALL 1 1/2" = 1'-0"A5 CURTAIN WALL THRESHOLD @ BALCONY 1 1/2" = 1'-0"A1 SECTION DETAIL @ EWS-2 BASE REVISION SCHEDULE NAME DATE DD Addendum 1 4/9/2020 Received by DiMarco 2/15/2021