HomeMy WebLinkAboutA502 Exterior DetailsRS-2RS-1EWS-3
EWS-2 RS-1RS-1FS-1EWS-2
RS-2RS-2EWS-1SIM
EWS-3EWS-3SIMEWS-3CS-1EWS-2
EWS-1FS-1ECW-1
EWS-2CS-1EWS-2
EWS-1 FS-1PRE-FORMED SEAMLESS
PIPE FLASHING BOOT
VENT PIPE OR STRUCTURAL
SUPPORT
ROOF SYSTEM STANDARD
JOINT SEALANT
STAINLESS STEEL CLAMPING
RING
WATER CUT-OFF MASTIC
ROOF SYSTEM
2'-0"
TAPER 1/2" PER FOOT
ROOF MEMBRANE
ROOF DRAIN
ROOF MEMBRANE
ROOF SYSTEM STANDARD
JOINT SEALANT
ROOF SYSTEM
PROVIDE GRAVEL GUARD AT RS-2
MINIMUM1' - 0"ROOF SYSTEM STANDARD
JOINT SEALANT
ROOF SYSTEM
ROOF SYSTEM FLASHING
MEMBRANE
EQUIPMENT CURB AND
INTEGRAL CAP FLASHING
MECHANICAL EQUIPMENT
ROOF MEMBRANE
ROOF HATCH
ROOF CURB
BLOCKING AS
REQUIRED
SEE STRUCTURAL
DRAWINGS FOR ROOF
OPENING FRAMING
5/8" GYPSUM BOARD ON
METAL FRAMING
5/8" GYPSUM BOARD ON
METAL FRAMING
CANT
FULLY ADHERED MEMBRANE
ROOFING
GLASS-MAT GYPSUM
SHEATHING
CANT
SIM
FULLY ADHERED
MEMBRANE ROOFING
EXTEND VAPOR
RETARDER UP
SHEATHING TO TOP
OF CANT
WOOD BLOCKING, AS
REQUIRED
FULLY ADHERED MEMBRANE
ROOFINGEXTEND ROOF MEMBRANE
DOWN FACE, AND
MECHANICALLY FASTEN TO
BLOCKING
JOIN AIR BARRIER SYSTEM
OF WALL TO AIR BARRIER
SYSTEM OF ROOF WITH
TRANSITION FLASHING
CONTINUOUS
VAPOR-PERMEABLE AIR
BARRIER SYSTEM
SEE STRUCTURAL
DRAWINGS FOR
STAIR ROOF
FRAMING
METAL FASCIA
ALUMINUM FLASHING WITH
DRIP TO MATCH METAL
COMPOSITE PANELS
CONTINUOUS SEALANT ENTIRE
PERIMETER OF DOOR FRAME
LAP WEATHER BARRIER UNDER
AND OVER FLASHING
ALUMINUM GUTTER
SLOPE, 1/4"/FT
FLASHING
CANT
THERMALLY BROKEN
EXTERIOR THRESHOLD
CONTINUOUS
SEALANT
ALUMINUM SUB SILL
EXTEND ROOF MEMBRANE UP
OVER BLOCKING AND UNDER
THRESHOLD
BENT PLATE
THERMAL ISOLATION
MATERIAL
MEMBRANE FLASHING
1' - 0"STAINLESS STEEL COUNTER
FLASHING WITH MIN 1/2" DRIP
FULLY ADHERED MEMBRANE
ROOFING
CANT
ROOFING MANUFACTURER'S
STANDARD TERMINATION
B/O LOW ROOF DECK
124' -6"
T/O LOW ROOF PARAPET
125' -11"6 1/2"CONTINUOUS
VAPOR-IMPERMEABLE AIR
BARRIER SYSTEM
EXTEND ROOF MEMBRANE
DOWN FACE, AND
MECHANICALLY FASTEN TO
BLOCKING
JOIN AIR BARRIER SYSTEM
OF WALL TO AIR BARRIER
SYSTEM OF ROOF WITH
TRANSITION FLASHING
METAL FASCIA
CANT
WOOD BLOCKING, AS
REQUIRED
W
FULLY ADHERED
MEMBRANE ROOFING
WEEP/VENT 24" OC
D
PLYWOOD SHEATHING
EXTEND MEMBRANE ROOFING DOWN
THE EXTERIOR FACE OF PARAPET
AND JOIN AIR BARRIER SYSTEM OF
WALL WITH TRANSITION FLASHING
SEAL AIR BARRIER SYSTEM
TO CURTAIN WALL
T/O CURTAIN WALL
176' -4"
METAL FASCIA6"5"3"1' - 4"
CFMF TRUSS, SEE STRUCTURAL DRAWINGS
SEE STRUCTURAL DRAWINGS
FOR TRUSS BEARING AND
BRACES
COMPOSITE METAL PANEL
RAINSCREEN
SEE STRUCTURAL DRAWINGS
FOR TRUSS BEARING
WITHOUT COVER BOARD AND ROOF MEMBRANEA502
A9
SIM
CONTINUOUS
VAPOR-PERMEABLE AIR
BARRIER SYSTEM
PLYWOOD SHEATHING
PLYWOOD SHEATHING
FULLY ADHERED MEMBRANE
ROOFING
SEE STRUCTURAL DRAWINGS
FOR THERMAL BREAK, LOCATE
WITHIN ROOF INSULATION
7' - 0"
FULLY ADHERED
MEMBRANE
ROOFING
FILL WITH CLOSED-CELL
INSULATION, TYPICAL
A503
G8
SEE STRUCTURAL FOR ANGLE
SUPPORT @ 6'-0" OC TO ALIGN WITH
CURTAIN WALL VERTICAL MULLIONS
FIRESTOP
SEALANT
FIRESAFING
INSULATION
3" CONTINUOUS LINEAR ALUMINUM SOFFIT VENT
NOTE: OMIT VENT AT AREAS OF RATED CONSTRUCTION;
SEE ROOF CODE CONFORMANCE PLAN
3" CONTINUOUS LINEAR ALUMINUM SOFFIT VENT
NOTE: OMIT VENT AT AREAS OF RATED CONSTRUCTION;
SEE ROOF CODE CONFORMANCE PLAN
TO MATCH
METAL COMPOSITE PANEL
RAINSCREEN SYSTEM
WOOD BLOCKING, AS REQUIRED
NOTE: FR BLOCKING AT AREAS OF
RATED CONSTRUCTION; SEE
ROOF CODE CONFORMANCE PLAN
5/8" GYPSUM BOARD
PROVIDE AT AREAS OF RATED CONSTRUCTION;
SEE ROOF CODE CONFORMANCE PLAN
5/8" GLASS-MAT GYPSUM
SHEATHING IN LIEU OF PLYWOOD
PROVIDE AT AREAS OF RATED
CONSTRUCTION; SEE ROOF CODE
CONFORMANCE PLANMETAL FRAMING OR FR WOOD BLOCKING, AT PANEL
JOINTS AT AREAS OF RATED CONSTRUCTION; SEE
ROOF CODE CONFORMANCE PLAN
THIRD FLOOR
128' -6"
1
WEATHER BARRIER
A501
H5
4" LEG AIR BARRIER STRIP
AT CORNER TO OVERLAP
HORIZONTAL AND VERTICAL
AIR BARRIER SYSTEM, TYP
JOIN AIR BARRIER SYSTEM
OF HORIZONTAL WALL TO
AIR BARRIER SYSTEM OF
VERTICAL WALL
SLOPE 1/4" : 12"
BACK ROD AND SEALANT
8"EXTEND AIR BARRIER INTO
ROUGH OPENING AND SEAL TO
CURTAIN WALL AND FLASHING
ALUMINUM FLASHING WITH DRIP
TO MATCH METAL COMPOSITE
MATERIAL WALL PANELS (MCP-1)
SINGLE-PIECE MULLION COVER
THERMAL ISOLATION MATERIAL
SEAL WEATHER
BARRIER TO AIR
BARRIER
FIRESTOP
SEALANT
ALUMINUM
TRIM
FIRESAFING
INSULATION
WEEP & BAFFLE
THIRD FLOOR
128' -6"
1
A501
H5
WEATHER BARRIER
CONTINUOUS
VAPOR-PERMEABLE AIR
BARRIER SYSTEM
WEEP & BAFFLE
DATE:
PROJECT:
OTHER:
DRAWN BY:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Architecture
Planning
Interior Design
11 12
H
I
11 12
H
I
619 West State Street
Ithaca, New York 14850
132 E. Jefferson Street
Syracuse, New York 13202
p 607 273 7600 www.holt.com
WARNING: It is a violation of New
York State Law for any person,
unless acting under the direction of
a licensed Architect, to alter this
document in any way. If a document
bearing the seal of an Architect is
altered, the altering Architect shall
affix to such document his seal and
the notation "altered by" followed by
his signature, the date of such
alteration, and a specific description
of the alteration.2/10/2021 2:36:49 PMA502
EXTERIOR
DETAILS
02/05/2021
2018089
CRB, GLM Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1 1/2" = 1'-0"A7 TYPICAL ROOF PENETRATION
1 1/2" = 1'-0"E7 ROOF DRAIN
1 1/2" = 1'-0"A11 EQUIPMENT CURB DETAIL
1 1/2" = 1'-0"F11 ROOF HATCH
1 1/2" = 1'-0"A9 ROOF CANT - TYPICAL
1 1/2" = 1'-0"D11 DOOR HEAD @ STAIR 2 ROOF
1 1/2" = 1'-0"B11 DOOR THRESHOLD @ STAIR 2 ROOF
1 1/2" = 1'-0"B9 ROOF BASE FLASHING @ METAL PANEL
1 1/2" = 1'-0"E9 FASCIA @ BRICK - TYPICAL
1 1/2" = 1'-0"E1 ROOF DETAIL @ TOP OF CURTAINWALL
1 1/2" = 1'-0"A5 CURTAIN WALL THRESHOLD @ BALCONY
1 1/2" = 1'-0"A1 SECTION DETAIL @ EWS-2 BASE
REVISION SCHEDULE
NAME DATE
DD
Addendum
1
4/9/2020
Received by DiMarco 2/15/2021