HomeMy WebLinkAboutA463 Stair 1 SectionsFIRST FLOOR
100' -0"
SECOND FLOOR
114' -0"
ROOF
174' -0"
THIRD FLOOR
128' -6"
FOURTH FLOOR
144' -0"
FIFTH FLOOR
158' -0"
3 3.8
12 RISERS @ 7"7' - 0"12 RISERS @ 7"7' - 0"14 RISERS @ 6 7/8"7' - 5 1/2"13 RISERS @ 6 7/8"8' - 0 1/2"10' - 10"8' - 3"11' - 0"13' - 0"12' - 0"13 RISERS @ 6 7/8"7' - 6 1/2"12 RISERS @ 6 7/8"6' - 11 1/2"12 RISERS @ 7"7' - 7"11 RISERS @ 7"6' - 5"A469
D7 TYP
A469
E10 TYP
G1
A468
TYP
________________________________________________
CEILING SYSTEM,
REFER TO RCP
CEILING SYSTEM,
REFER TO RCP
CEILING SYSTEM,
REFER TO RCP11' - 6"TYPE 1 GUARDRAIL
AND HANDRAIL
EXTEND GUARDRAIL
AND HANDRAIL TO BE
CONTINUOUS TO
ADJACENT HANDRAIL &
GUARDRAIL
TYPE 1 GUARDRAIL
AND HANDRAIL
EXTEND GUARDRAIL
AND HANDRAIL TO BE
CONTINUOUS TO
ADJACENT HANDRAIL &
GUARDRAIL
TYPE 1 GUARDRAIL
AND HANDRAIL
TYPE 1 GUARDRAIL
AND HANDRAIL
EXTEND GUARDRAIL
AND HANDRAIL TO BE
CONTINUOUS TO
ADJACENT HANDRAIL &
GUARDRAIL
INTUMESCENT
COATED
STRUCTURE, TYP
NON-COMBUSTIBLE
CONCEALED SPACE
BELOW STAIR
TYPE 1A
GUARDRAIL AND
HANDRAIL
CAST-IN-PLACE
CONCRETE STAIR FROM
1ST TO 2ND FLOOR
CEILING SYSTEM,
REFER TO RCP,
TYP 10' - 6"9
2BALIGNALIGN9
2BALIGNALIGN9
2B
9
2B
2B
11' - 9"CEILING SYSTEM,
REFER TO RCP
FIRST FLOOR
100' -0"
SECOND FLOOR
114' -0"
ROOF
174' -0"
THIRD FLOOR
128' -6"
FOURTH FLOOR
144' -0"
FIFTH FLOOR
158' -0"
STAIR 1 -LANDING 1
106' -5"
NON-COMBUSTIBLE
CONCEALED SPACE
BELOW STAIR
CAST-IN-PLACE
CONCRETE STAIR FROM
1ST TO 2ND FLOOR
TYPE 3A HANDRAIL
TYPE 3 HANDRAIL
A469
A9 11' - 6"10' - 6"13' - 0"12' - 0"CEILING SYSTEM,
REFER TO RCP
CEILING SYSTEM,
REFER TO RCP
CEILING SYSTEM,
REFER TO RCP
11' - 0"8' - 3"A469
D7
TYP
G1
A468
TYP
________________________________________________
A1
A468
________________________________________________
A7
A468
________________________________________________
TYPE 1 GUARDRAIL AND
HANDRAIL
EXTEND GUARDRAIL
AND HANDRAIL TO BE
CONTINUOUS TO
ADJACENT HANDRAIL &
GUARDRAIL
TYPE 1 GUARDRAIL
AND HANDRAIL
EXTEND GUARDRAIL
AND HANDRAIL TO BE
CONTINUOUS TO
ADJACENT HANDRAIL &
GUARDRAIL
A468
G1 TYP
TYPE 1 GUARDRAIL
AND HANDRAIL 10' - 10"CEILING SYSTEM,
REFER TO RCP,
TYP
9
2BALIGNALIGNALIGNALIGN 9
2B
2B
9
9
2B
REFER TO A002 FOR
UL ASSEMBLY, TYP
FIRST FLOOR
100' -0"
SECOND FLOOR
114' -0"
ROOF
174' -0"
THIRD FLOOR
128' -6"
FOURTH FLOOR
144' -0"
FIFTH FLOOR
158' -0"
STAIR 1 -LANDING 1
106' -5"
PARAPET -LOW POINT
179' -4"1' - 8 1/2"SOLID SURFACE
SILL
9
2A ALIGNREFER TO A002 FOR
UL ASSEMBLY, TYP
FIRST FLOOR
100' -0"
SECOND FLOOR
114' -0"
ROOF
174' -0"
THIRD FLOOR
128' -6"
FOURTH FLOOR
144' -0"
FIFTH FLOOR
158' -0"
STAIR 1 -LANDING 1
106' -5"11 RISERS @ 7"6' - 5"12 RISERS @ 7"7' - 7"12 RISERS @ 6 7/8"6' - 11 1/2"13 RISERS @ 6 7/8"7' - 6 1/2"14 RISERS @ 6 7/8"8' - 0 1/2"13 RISERS @ 6 7/8"7' - 5 1/2"12 RISERS @ 7"7' - 0"12 RISERS @ 7"7' - 0"TYPE 1 GUARDRAIL
AND HANDRAIL
EXTEND GUARDRAIL AND
HANDRAIL TO BE
CONTINUOUS WITH
ADJACENT GUARDRAIL
AND HANDRAIL
G1
A468
TYP
________________________________________________
TYPE 1 GUARDRAIL
AND HANDRAIL
EXTEND GUARDRAIL AND
HANDRAIL TO BE
CONTINUOUS WITH
ADJACENT GUARDRAIL
AND HANDRAIL
CAST-IN-PLACE
CONCRETE STAIR
FROM 1ST TO 2ND
FLOOR WITH PRECAST
TERRAZZO TREADS,
RISERS & MID-LANDING
TYPE 1 GUARDRAIL
AND HANDRAIL
EXTEND GUARDRAIL AND
HANDRAIL TO BE
CONTINUOUS WITH
ADJACENT GUARDRAIL
AND HANDRAIL
TYPE 1A GUARDRAIL
AND HANDRAIL
NON-COMBUSTIBLE
CONCEALED SPACE
BELOW STAIRA469
A9
A469
D7 TYP
A469
E10 TYP
CEILING SYSTEM,
REFER TO RCP, TYP
CEILING SYSTEM,
REFER TO RCP,
TYP
9
2B ALIGNALIGNALIGNALIGN9
2B
9
2B
2B
9
DATE:
PROJECT:
OTHER:
DRAWN BY:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Architecture
Planning
Interior Design
11 12
H
I
11 12
H
I
619 West State Street
Ithaca, New York 14850
132 E. Jefferson Street
Syracuse, New York 13202
p 607 273 7600 www.holt.com
WARNING: It is a violation of New
York State Law for any person,
unless acting under the direction of
a licensed Architect, to alter this
document in any way. If a document
bearing the seal of an Architect is
altered, the altering Architect shall
affix to such document his seal and
the notation "altered by" followed by
his signature, the date of such
alteration, and a specific description
of the alteration.2/5/2021 4:53:02 PMA463
STAIR #1
SECTIONS
02/05/2021
2018089
AMW, KAS Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1/4" = 1'-0"A9 STAIR 1 SECTION - EAST/WEST 3
1/4" = 1'-0"A6 STAIR 1 SECTION - EAST/WEST 2
1/4" = 1'-0"A1 STAIR 1 SECTION - NORTH/SOUTH
1/4" = 1'-0"A3 STAIR #1 SECTION - EAST/WEST 1
REVISION SCHEDULE
NAME DATE
Received by DiMarco 2/15/2021