HomeMy WebLinkAboutA455 Wall SectionsRS-2FWS-1 FS-1FS-2CS-2EWS-1
ESF-1RS-2EWS-1
FWS-1FS-1FS-2CS-2ESF-1 RS-2RS-2FWS-1CS-2ESF-1
CS-2FIRST FLOOR
100' -0"
SECOND FLOOR
114' -0"
B/O LOW ROOF DECK
124' -6"
3.9
T/O LOW ROOF PARAPET
125' -11"
A502
F11
A502
E9
A501
F1
A501
H3
A501
F3
SIM
A501
F11
A501
D11
1' - 4"
FIRST FLOOR
100' -0"
SECOND FLOOR
114' -0"
B/O LOW ROOF DECK
124' -6"
E
T/O LOW ROOF PARAPET
125' -11"
A502
E9 OPP
A501
F1
OPP
A455
F2
A501
F3
OPP
A2
A455
________________________________________________COURSEBRICK HEADER66 BRICK COURSESD2
A455
________________________________________________
MOCKUP AREA #3
MOCKUP AREA #3
- ROWLOCK BRICK COURSE TRANSITION TO WOOD RAINSCREEN SOFFIT
- WOOD SOFFIT TRANSITION TO LIGHT FIXTURE
- LIGHT FIXTURE TRANSITION TO STOREFRONT
- WOOD SOFFIT TRANSITION TO WOOD SIDING
- WOOD SIDING TRANSITION TO PRECAST SILL
- SEALANT JOINT BETWEEN WOOD SIDING AND BRICK
- PRECAST SILL AND KNEE WALL INSIDE CORNER
- PRECAST KNEE WALL
- ELECTRICAL JUNCTION BOX FOR CARD READER TO
SHOW INSTALLATION AND SEALED CONDITIONS
INTENT OF MOCKUP IS TO CONDUCT INTERMITTENT VISUAL ENVELOPE
COMMISSIONING INSPECTIONS.
ROOF
174' -0"
PENTHOUSE
183' -4"
A502
D11
A502
B11
STAIR LANDING
FIRST FLOOR
100' -0"GROUT SOLID
EXTEND WATERPROOFING
OVER LEDGE AND UP FACE
OF WALL UNDER EMBEDDED
FLASHING
CAST STONE PANEL
TONGUE AND GROOVE WOOD SIDING
(WD1); FINISHED FACE OF WOOD TO
ALIGN WITH FACE OF BRICK
2X VERTICAL WOOD FURRING @ 12" OC
3/4" RAINSCREEN SIDING VENT
BASIS-OF-DESIGN: CORAVENT INC.
RAINSCREEN SIDING SYSTEM STURDI-STRIP
MEMBRANE FLASHING
WEATHER BARRIER
EMBEDDED FLASHING
CONTINUOUS FIBERGLASS
INSECT SCREEN, EXTEND 3" MINIMUM
VERTICALLY, WRAP AND FOLD AT ENDS
CONTINUOUS ALUMINUM SUB SILL, TO
ALIGN AN MATCH PROFILE OF ALUMINUM
SUBSILL AT STOREFRONT; PROVIDE 90
DEGREE INSIDE CORNER AT STOREFRONT
CONTINUOUS SEALANT
COMPOSITE POLYISOCYANURATE
BOARD INSULATION, FASTEN TO STUD
3 1/2" MINERAL WOOL
BATT INSULATION
6" CFMS @ 24" OC (16 GA)
5/8" GYPSUM BOARD
1/2" GLASS-MAT
GYPSUM SHEATHING
CONTINUOUS VAPOR-PERMEABLE
AIR BARRIER SYSTEM
F3
A501
________________________________________________
BACKER ROD AND SEALANT
BOTH SIDES
EXTEND AIR BARRIER
SYSTEM INTO ROUGH
OPENING AND SEAL
BACK ROD AND SEALANT
LINEAR LIGHT FIXTURE, SEE
ELECTRICAL DRAWINGS
AIR CURTAIN, SEE
MECHANICAL DRAWINGS
COMPOSITE POLYISOCYANURATE
BOARD INSULATION, FASTEN TO STUD
3 1/2" MINERAL WOOL
BATT INSULATION
6" CFMS @ 24" OC (16 GA)
5/8" GYPSUM BOARD
1/2" GLASS-MAT
GYPSUM SHEATHING
CONTINUOUS VAPOR-PERMEABLE
AIR BARRIER SYSTEM
TONGUE AND GROOVE WOOD SIDING (WD1)
2X VERTICAL WOOD FURRING @ 12" OC
3/4" RAINSCREEN SIDING VENT
BASIS-OF-DESIGN: CORAVENT INC.
RAINSCREEN SIDING SYSTEM STURDI-STRIP
WEATHER BARRIER
SOFFIT VENT
BASIS-OF-DESIGN: FRY REGLET PERIMETER
SOFFIT VENT 1680-V; BLACK POWDER-COAT FINISH
ROUT BOARD EDGE TO FIT TRIM
DATE:
PROJECT:
OTHER:
DRAWN BY:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Architecture
Planning
Interior Design
11 12
H
I
11 12
H
I
619 West State Street
Ithaca, New York 14850
132 E. Jefferson Street
Syracuse, New York 13202
p 607 273 7600 www.holt.com
WARNING: It is a violation of New
York State Law for any person,
unless acting under the direction of
a licensed Architect, to alter this
document in any way. If a document
bearing the seal of an Architect is
altered, the altering Architect shall
affix to such document his seal and
the notation "altered by" followed by
his signature, the date of such
alteration, and a specific description
of the alteration.2/5/2021 8:25:24 PMA455
WALL
SECTIONS
02/05/2021
2018089
CRB, GLM Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1/2" = 1'-0"A9 WALL SECTION AT MAIN ENTRANCE
1/2" = 1'-0"A5 WALL SECTION AT MAIN LOBBY
1/2" = 1'-0"G5 WALL SECTION @ STAIR 2 ROOF REVISION SCHEDULE
NAME DATE
1 1/2" = 1'-0"A2 SECTION @ WOOD RAINSCREEN
1 1/2" = 1'-0"F2 CEILING DETAIL @ AIR CURTAIN
1 1/2" = 1'-0"D2 WOOD RAINSCREEN SOFFIT VENT
Received by DiMarco 2/15/2021