Loading...
HomeMy WebLinkAboutA455 Wall SectionsRS-2FWS-1 FS-1FS-2CS-2EWS-1 ESF-1RS-2EWS-1 FWS-1FS-1FS-2CS-2ESF-1 RS-2RS-2FWS-1CS-2ESF-1 CS-2FIRST FLOOR 100' -0" SECOND FLOOR 114' -0" B/O LOW ROOF DECK 124' -6" 3.9 T/O LOW ROOF PARAPET 125' -11" A502 F11 A502 E9 A501 F1 A501 H3 A501 F3 SIM A501 F11 A501 D11 1' - 4" FIRST FLOOR 100' -0" SECOND FLOOR 114' -0" B/O LOW ROOF DECK 124' -6" E T/O LOW ROOF PARAPET 125' -11" A502 E9 OPP A501 F1 OPP A455 F2 A501 F3 OPP A2 A455 ________________________________________________COURSEBRICK HEADER66 BRICK COURSESD2 A455 ________________________________________________ MOCKUP AREA #3 MOCKUP AREA #3 - ROWLOCK BRICK COURSE TRANSITION TO WOOD RAINSCREEN SOFFIT - WOOD SOFFIT TRANSITION TO LIGHT FIXTURE - LIGHT FIXTURE TRANSITION TO STOREFRONT - WOOD SOFFIT TRANSITION TO WOOD SIDING - WOOD SIDING TRANSITION TO PRECAST SILL - SEALANT JOINT BETWEEN WOOD SIDING AND BRICK - PRECAST SILL AND KNEE WALL INSIDE CORNER - PRECAST KNEE WALL - ELECTRICAL JUNCTION BOX FOR CARD READER TO SHOW INSTALLATION AND SEALED CONDITIONS INTENT OF MOCKUP IS TO CONDUCT INTERMITTENT VISUAL ENVELOPE COMMISSIONING INSPECTIONS. ROOF 174' -0" PENTHOUSE 183' -4" A502 D11 A502 B11 STAIR LANDING FIRST FLOOR 100' -0"GROUT SOLID EXTEND WATERPROOFING OVER LEDGE AND UP FACE OF WALL UNDER EMBEDDED FLASHING CAST STONE PANEL TONGUE AND GROOVE WOOD SIDING (WD1); FINISHED FACE OF WOOD TO ALIGN WITH FACE OF BRICK 2X VERTICAL WOOD FURRING @ 12" OC 3/4" RAINSCREEN SIDING VENT BASIS-OF-DESIGN: CORAVENT INC. RAINSCREEN SIDING SYSTEM STURDI-STRIP MEMBRANE FLASHING WEATHER BARRIER EMBEDDED FLASHING CONTINUOUS FIBERGLASS INSECT SCREEN, EXTEND 3" MINIMUM VERTICALLY, WRAP AND FOLD AT ENDS CONTINUOUS ALUMINUM SUB SILL, TO ALIGN AN MATCH PROFILE OF ALUMINUM SUBSILL AT STOREFRONT; PROVIDE 90 DEGREE INSIDE CORNER AT STOREFRONT CONTINUOUS SEALANT COMPOSITE POLYISOCYANURATE BOARD INSULATION, FASTEN TO STUD 3 1/2" MINERAL WOOL BATT INSULATION 6" CFMS @ 24" OC (16 GA) 5/8" GYPSUM BOARD 1/2" GLASS-MAT GYPSUM SHEATHING CONTINUOUS VAPOR-PERMEABLE AIR BARRIER SYSTEM F3 A501 ________________________________________________ BACKER ROD AND SEALANT BOTH SIDES EXTEND AIR BARRIER SYSTEM INTO ROUGH OPENING AND SEAL BACK ROD AND SEALANT LINEAR LIGHT FIXTURE, SEE ELECTRICAL DRAWINGS AIR CURTAIN, SEE MECHANICAL DRAWINGS COMPOSITE POLYISOCYANURATE BOARD INSULATION, FASTEN TO STUD 3 1/2" MINERAL WOOL BATT INSULATION 6" CFMS @ 24" OC (16 GA) 5/8" GYPSUM BOARD 1/2" GLASS-MAT GYPSUM SHEATHING CONTINUOUS VAPOR-PERMEABLE AIR BARRIER SYSTEM TONGUE AND GROOVE WOOD SIDING (WD1) 2X VERTICAL WOOD FURRING @ 12" OC 3/4" RAINSCREEN SIDING VENT BASIS-OF-DESIGN: CORAVENT INC. RAINSCREEN SIDING SYSTEM STURDI-STRIP WEATHER BARRIER SOFFIT VENT BASIS-OF-DESIGN: FRY REGLET PERIMETER SOFFIT VENT 1680-V; BLACK POWDER-COAT FINISH ROUT BOARD EDGE TO FIT TRIM DATE: PROJECT: OTHER: DRAWN BY: A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 11 12 H I 11 12 H I 619 West State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration.2/5/2021 8:25:24 PMA455 WALL SECTIONS 02/05/2021 2018089 CRB, GLM Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1/2" = 1'-0"A9 WALL SECTION AT MAIN ENTRANCE 1/2" = 1'-0"A5 WALL SECTION AT MAIN LOBBY 1/2" = 1'-0"G5 WALL SECTION @ STAIR 2 ROOF REVISION SCHEDULE NAME DATE 1 1/2" = 1'-0"A2 SECTION @ WOOD RAINSCREEN 1 1/2" = 1'-0"F2 CEILING DETAIL @ AIR CURTAIN 1 1/2" = 1'-0"D2 WOOD RAINSCREEN SOFFIT VENT Received by DiMarco 2/15/2021