Loading...
HomeMy WebLinkAboutA454 Wall SectionsEWS-1 EWS-2 CS-1FWS-1 EWS-1 FS-2SIMRS-1EWS-2 SIM EWS-2 EWS-2 EWS-1 ECW-1 CS-1EWS-2EWS-2 EWS-1 FS-2SIMRS-1CS-1ECW-1 ECW-1 SIM EWS-2 SIM EWS-2 FIRST FLOOR 100' -0" SECOND FLOOR 114' -0" THIRD FLOOR 128' -6" FOURTH FLOOR 144' -0" 1 A501 A5 A501 D7 FOURTH FLOOR 144' -0" FIFTH FLOOR 158' -0" 1 5/8" GYPSUM BOARD NON-STRUCTURAL METAL FRAMING POLYISOCYANURATE BOARD INSULATION CLOSED -CELL SPRAY- APPLIED INSULATION 5/8" GYPSUM BOARD ON METAL FRAMING NON-STRUCTURAL METAL FRAMING SEE STRUCTURAL DRAWINGS FOR CFMF FRAMING SUBSTRATE BOARD SEE REFLECTED CEILING PLAN FOR CEILING CRICKET REFER TO B9/A002 FOR UL ASSEMBLY AT BEAM INTUMESENT FIREPROOFING AT STEEL BEAM AND PLATE 9 ' - 11 1 /4" JOINT AT GYPSUM SHEATHING IN THIS LOCATION, LAP DRAINAGE PLANE MATERIAL OVER JOINT FIRST FLOOR 100' -0" SECOND FLOOR 114' -0" THIRD FLOOR 128' -6" FOURTH FLOOR 144' -0" 1 A501 D7 A503 F10 A503 A2 CURTAIN WALL ANCHOR METAL COMPOSITE MATERIAL WALL PANELS (MCP-1), BEYOND HORIZONTAL JOINTS TO ALIGN WITH HORIZONTAL JOINTS IN SOUTH ELEVATION A501 A5 FOURTH FLOOR 144' -0" FIFTH FLOOR 158' -0" 1 A503 F10 A503 F10 CLOSED -CELL SPRAY- APPLIED INSULATION 5/8" GYPSUM BOARD ON METAL FRAMING ? CURTAIN WALL ANCHOR CURTAIN WALL ANCHOR SEE STRUCTURAL DRAWINGS FOR CFMF FRAMING POLYISOCYANURATE BOARD INSULATION A503 G6 SEE REFLECTED CEILING PLAN FOR CEILING CRICKET 6"2' - 0" METAL COMPOSITE MATERIAL WALL PANELS (MCP-1), BEYOND HORIZONTAL JOINTS TO ALIGN WITH HORIZONTAL JOINTS IN SOUTH ELEVATION VERTICAL JOINTS TO ALIGN WITH HORIZONTAL SOFFIT JOINTS ABOVE METAL COMPOSITE MATERIAL WALL PANELS (MCP-1), BEYOND INTUMESENT FIREPROOFING AT STEEEL BEAM AND PLATE DATE: PROJECT: OTHER: DRAWN BY: A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 11 12 H I 11 12 H I 619 West State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration.2/5/2021 4:52:27 PMA454 WALL SECTIONS 02/05/2021 2018089 CRB/GLM Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1/2" = 1'-0"A1 WALL SECTION @ BRICK-TO-METAL PANEL WRAPPER - BASE 1/2" = 1'-0"A7 WALL SECTION @ BRICK-TO-METAL PANEL WRAPPER REVISION SCHEDULE NAME DATE Received by DiMarco 2/15/2021