HomeMy WebLinkAboutA454 Wall SectionsEWS-1
EWS-2
CS-1FWS-1
EWS-1
FS-2SIMRS-1EWS-2
SIM
EWS-2
EWS-2
EWS-1
ECW-1
CS-1EWS-2EWS-2
EWS-1
FS-2SIMRS-1CS-1ECW-1
ECW-1
SIM
EWS-2
SIM
EWS-2
FIRST FLOOR
100' -0"
SECOND FLOOR
114' -0"
THIRD FLOOR
128' -6"
FOURTH FLOOR
144' -0"
1
A501
A5
A501
D7
FOURTH FLOOR
144' -0"
FIFTH FLOOR
158' -0"
1
5/8" GYPSUM BOARD
NON-STRUCTURAL METAL
FRAMING
POLYISOCYANURATE BOARD
INSULATION
CLOSED -CELL SPRAY-
APPLIED INSULATION
5/8" GYPSUM BOARD ON
METAL FRAMING
NON-STRUCTURAL METAL
FRAMING
SEE STRUCTURAL DRAWINGS
FOR CFMF FRAMING
SUBSTRATE BOARD
SEE REFLECTED CEILING
PLAN FOR CEILING
CRICKET
REFER TO B9/A002 FOR
UL ASSEMBLY AT BEAM
INTUMESENT FIREPROOFING
AT STEEL BEAM AND PLATE
9
' - 11
1
/4"
JOINT AT GYPSUM
SHEATHING IN THIS
LOCATION, LAP DRAINAGE
PLANE MATERIAL OVER JOINT
FIRST FLOOR
100' -0"
SECOND FLOOR
114' -0"
THIRD FLOOR
128' -6"
FOURTH FLOOR
144' -0"
1
A501
D7
A503
F10
A503
A2
CURTAIN WALL
ANCHOR
METAL COMPOSITE
MATERIAL WALL PANELS
(MCP-1), BEYOND
HORIZONTAL JOINTS TO
ALIGN WITH HORIZONTAL
JOINTS IN SOUTH
ELEVATION
A501
A5
FOURTH FLOOR
144' -0"
FIFTH FLOOR
158' -0"
1
A503
F10
A503
F10
CLOSED -CELL SPRAY-
APPLIED INSULATION
5/8" GYPSUM BOARD ON
METAL FRAMING
?
CURTAIN WALL
ANCHOR
CURTAIN WALL
ANCHOR
SEE STRUCTURAL DRAWINGS
FOR CFMF FRAMING
POLYISOCYANURATE BOARD
INSULATION
A503
G6
SEE REFLECTED CEILING
PLAN FOR CEILING
CRICKET
6"2' - 0"
METAL COMPOSITE
MATERIAL WALL PANELS
(MCP-1), BEYOND
HORIZONTAL JOINTS TO
ALIGN WITH HORIZONTAL
JOINTS IN SOUTH
ELEVATION
VERTICAL JOINTS TO
ALIGN WITH HORIZONTAL
SOFFIT JOINTS ABOVE
METAL COMPOSITE
MATERIAL WALL PANELS
(MCP-1), BEYOND
INTUMESENT FIREPROOFING
AT STEEEL BEAM AND PLATE
DATE:
PROJECT:
OTHER:
DRAWN BY:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Architecture
Planning
Interior Design
11 12
H
I
11 12
H
I
619 West State Street
Ithaca, New York 14850
132 E. Jefferson Street
Syracuse, New York 13202
p 607 273 7600 www.holt.com
WARNING: It is a violation of New
York State Law for any person,
unless acting under the direction of
a licensed Architect, to alter this
document in any way. If a document
bearing the seal of an Architect is
altered, the altering Architect shall
affix to such document his seal and
the notation "altered by" followed by
his signature, the date of such
alteration, and a specific description
of the alteration.2/5/2021 4:52:27 PMA454
WALL
SECTIONS
02/05/2021
2018089
CRB/GLM Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1/2" = 1'-0"A1 WALL SECTION @ BRICK-TO-METAL PANEL WRAPPER - BASE
1/2" = 1'-0"A7 WALL SECTION @ BRICK-TO-METAL PANEL WRAPPER
REVISION SCHEDULE
NAME DATE
Received by DiMarco 2/15/2021