Loading...
HomeMy WebLinkAboutA451 Wall SectionsEWS-2 EWS-1 EWS-1FS-1FS-1FWS-1FS-2EWS-3 EWS-3 EWS-3 FS-1FS-1SIM EWS-3 EWS-3RS-1EWS-3 EWS-3 EWS-1RS-2FS-1ECW-1 ECW-1 EWS-3 EWS-2 RS-1ECW-1 EWS-3 FIRST FLOOR 100' -0" SECOND FLOOR 114' -0" THIRD FLOOR 128' -6" D 8" 1' - 3" A501 A5 A501 D7 A501 C5 A501 F5 A503 C8 A503 E8 ALL EXPOSED STRUCTURAL STEEL TO HAVE INTUMESCENT FIREPROOFING SEE REFLECTED CEILING PLAN FOR CEILING SEE REFLECTED CEILING PLAN FOR CEILING SEE REFLECTED CEILING PLAN FOR CEILING CURTAINWALL ANCHOR A503 A9 FOURTH FLOOR 144' -0" FIFTH FLOOR 158' -0" A502 E1 D A002 D11 T/O CURTAIN WALL 176' -4" 1' - 4" 1' - 4" 1' - 4" CFMF TRUSS, SEE STRUCTURAL DRAWINGS SEE STRUCTURAL DRAWINGS FOR TRUSS BEARING SEE REFLECTED CEILING PLAN FOR CEILING SEE REFLECTED CEILING PLAN FOR CEILING SEE REFLECTED CEILING PLAN FOR CEILING CURTAINWALL ANCHOR CURTAINWALL ANCHOR CURTAINWALL ANCHOR A503 C8 A503 C8 THIRD FLOOR 128' -6" FOURTH FLOOR 144' -0" FIFTH FLOOR 158' -0" B/O LOW ROOF DECK 124' -6" T/O LOW ROOF PARAPET 125' -11" D A502 E9 OPP A502 B9 SEE A8/A451 TYPICAL WALL SECTION FOR FIRST AND SECOND FLOOR INFORMATION ALL EXPOSED STRUCTURAL STEEL TO HAVE INTUMESCENT FIREPROOFING ALL EXPOSED STRUCTURAL STEEL TO HAVE INTUMESCENT FIREPROOFING CURTAINWALL ANCHOR CURTAINWALL ANCHOR SEE REFLECTED CEILING PLAN FOR CEILING ROOF 174' -0" FIFTH FLOOR 158' -0" D A502 E1 SIM T/O CURTAIN WALL 176' -4" ALL EXPOSED STRUCTURAL STEEL TO HAVE INTUMESCENT FIREPROOFING CFMF TRUSS, SEE STRUCTURAL DRAWINGS SEE STRUCTURAL DRAWINGS FOR TRUSS BEARING CURTAINWALL ANCHOR CURTAINWALL ANCHOR SEE REFLECTED CEILING PLAN FOR CEILING DATE: PROJECT: OTHER: DRAWN BY: A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 11 12 H I 11 12 H I 619 West State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration.2/5/2021 4:52:11 PMA451 WALL SECTIONS 02/05/2021 2018089 CRB/GLM Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1/2" = 1'-0"A8 TYPICAL WALL SECTION 1/2" = 1'-0"A1 WALL SECTION AT LOW ROOF & EXIT STAIR REVISION SCHEDULE NAME DATE Received by DiMarco 2/15/2021