HomeMy WebLinkAboutA350 Typical Mounting Heights & ElevationsNC
FEC
SD
FP
FA
E D
TPP HO OS TVSH NC TC
EM
EMA CO NO O O V VS W
RESIN PANEL
MINERAL
PROFILE PANEL
SOUND ABSORBING WALL
UNIT OR FINISH
1. 4" BASE TYPICAL, UON, REFER TO FINISH PLANS FOR
TYPE
2. OUTLETS, SWITCHES, THERMOSTATS, ALARMS, ETC.
SHOWN FOR COORDINATION PURPOSES ONLY. REFER TO
MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS
FOR FULL SCOPE.
3. PROVIDE 1' - 0" TALL BY 5' - 0" WIDE (UON) BLOCKING
FOR ALL WALL MOUNTED EQUIPMENT AND ACCESSORIES
4. REFER TO FINISH PLANS FOR ADDITIONAL ROOM AND
MILLWORK FINISH INFORMATION
5. REFER TO INTERIOR ELEVATIONS FOR MATERIAL OF
WALL SURFACES AND WALL CABINETS, CABINET
DRAWERS, CABINET DOORS, COUNTERTOPS,
COUNTERTOP EDGES, SIDESPLASHES AND
BACKSPLASHES
6. ALL CABINETS/DRAWERS EXCEPT WASTE/SOILED LINIEN
RECEPTACLES TO RECEIVE KEYED LOCKS. CONTRACTOR
SHALL KEY MILLWORK LOCKS SIMILAR THROUGHOUT THE
ENTIRE DEPARTMENT AREA. EACH DEPARTMENT SHALL
BE KEYED SEPARATELY FROM THE OTHER.
INTERIOR ELEVATION GENERAL NOTES:
INTERIOR ELEVATION MATERIAL LEGEND:
?
???
CABINET DESIGN SERIES NO.
(CDS NO.) PER
ARCHITECTURAL WOODWORK
INSTITUTE (AWI), SEE A551
FOR CORRESPONDING
DETAILS
CABINET HEIGHT
CABINET DEPTHCABINET WIDTH
CASEWORK TAG:
PROTRUDING OBJECTS
CLEAR FLOOR SPACE
Unless otherwise specified may include knee
and toe clearances
CIRCULAR TURNING SPACE
May include knee and toe clearances
'T-TURN' TURNING SPACE
May include knee and toe clearances only at
the end of either the base or one arm.
Forward
Approach
Side
Approach
4" MAX
80"27"15"5"3"3' -4"2' -11"3' -4" 4' -0"4' -0"EXCEPTIONS:
(1) HANDRAILS MAY PROTRUDE 4-1/2"
MAX.
(2) DOOR CLOSERS & STOPS MAY BE 78"
MIN. ABOVE THE FLOOR
FIG. 307.2
FIG. 603.4
COAT HOOK & SHELF MOUNTING HEIGHTS
FIG. 603.3
MIRROR MOUNTING HEIGHTS
NOTE: SEE REACH RANGES FOR
COAT HOOK MOUNTING HEIGHTS
NOTE: HEIGHT TO EDGE OF
REFLECTIVE SURFACE
FIG 602.5
DRINKING FOUNTAIN SPOUT
LOCATION
FIG. 604.5.2
REAR WALL GRAB BAR FOR WATER
CLOSET2' -10"TYPICAL CLEARANCES AND REACH RANGES - ANSI 2009
1' - 6"
1' - 0"2' - 0"
TYPICAL MOUNTING HEIGHTS AND CLEARANCES FOR PLUMBING FIXTURES
6' - 9" MIN6' - 2" MINSHELF
36" MIN.
WALL PROTECTION
GLAZING FILM ON
TEMPERED GLASS
33" -36"7" -9"
1 1/2"
NURSE CALL
REAR WALL GRAB BAR FOR
BARIATRIC WATER CLOSET
SIDE WALL GRAB BAR FOR BARIATRIC
WATER CLOSET
24"
18"
24".
5 1/4"5 1/4"33" - 36"17" - 19"4' - 0"59"54"
42"12"
(UNLESS OTHERWISE NOTED)IJINTERIOR ELEVATION SYMBOLS AND TYPICAL MOUNTING HEIGHTS
102800 - TOILET AND BATH ACCESSORIES
210000 - FIRE SUPPRESSION 2' - 0"BCDETYPE 1TYPE 2FGHKLNO5' - 6"4' - 0" (ADA)7' - 2"4' - 0"7' - 2"4' - 0"6"4' - 0" UONCOAT HOOK
4' - 0"6' - 8" MIN4' - 6"FIRE EXTINGUISHER CABINET (FEC)FIRE ALARM PULLFIRE ALARMSTROBE FIRE SPEAKER DEVICE1 1/2" MIN1' - 0" MIN3' - 2"TYPE 1TYPE 2TYPE 3MA
B
D
E
F
G
I
J
SANITARY NAPKIN DISPENSER
PAPER TOWEL DISPENSER
SOAP DISPENSER, NIC
MIRROR (TOP)
LAVATORY
TOP OF WATER CLOSET SEAT
GRAB BAR
ITEM
WASTE RECEPTACLE
C
K
LTOILET PAPER DISPENSER
URINAL
MOUNTING
HEIGHT
CODE REF.
ICC/ANSI
A117.1-2009
6' -2" MIN
M
N
O
DRINKING FOUNTAIN
SHOWER CURTAIN ROD
FOLDING SHOWER SEAT
SHOWER CONTROLSGRAB BAR AT TUB
SOAP DISH AT TUB
TOILET SEAT COVER DISPENSER
TOILET PARTITION PUSH PLATE
1' -6"
2' -10"
1' -5"
2' -10"
3' -8"
(1) 3' -6" (2) 3' -0"
3' -6"
3' -6"
3' -6"
2' -3"
9"
606.3
604.4
604.5
604.7
605.2
602.4
HOLT STANDARDS
610.3
608.5HOLT STANDARDS
HOLT STANDARDS
HOLT STANDARDS
HOLT STANDARDS
HOLT STANDARDS
HOLT STANDARDS
HOLT STANDARDS
HOLT STANDARDS3' -0"
ITEM
CODE REF.
ICC/ANSI
A117.1-2009
H
MIRROR (BOTTOM)3' -4" MAX 603.3
1' -6" to 4' -0"
1' -6"
HAND DRYER 3' -6"HOLT STANDARDS
SOAP DISH/ CORNER BASKET AT SHOWER 3' -6"HOLT STANDARDS
Q
R
T
U
V
S3' -4"
3' -6"
6' -10"
MOUNTING
HEIGHT
HOLT STANDARDS
260000 - ELECTRICAL DEVICES
224000 - PLUMBING FIXTURES
270000 - COMMUNICATION SYSTEMSQRST(1)T(2)VW5' - 6" UON3' 10" UON6' - 8" UONPOWER OUTLETPOWER DOOR OPERATOR PUSH PLATEDOOR HOLD OPENOCCUPANCY SENSORLIGHT SWITCHTHERMOSTATWALL SCONCE LIGHT FIXTUREVALANCE LIGHT FIXTURECLOCK, NICWALL MOUNTED FLAT PANEL TELEVISIONDATA OUTLETUON1' - 6"WALL MOUNTED TELEPHONEHUMIDITY CONTROLANALOG PHONE OUTLETFAIL SAFE PHONE OUTLETPFS ANALOG FAX OUTLETF 4' - 0"5' - 1"2"
HINGED SIDE OF DOOR
ROOM SIGN, SEE
SCHEDULE
LATCH SIDE OF DOOR
EDGE OF DOOR FRAME
OR EDGE OF OPENINGSIGN MOUNTING ELEVATION
TACK BOARD MARKER
BOARD
MAGAZINE
RACK
CORNER
GUARD 3' - 2"GLOVE
DISPENSER
SHARPS
CONTAINER4' - 0"4' - 0"CODE BLUEEMERGENCY POWERMEDICAL AIRCARBON DIOXIDENITROGENNITROUS OXIDEOXYGENVACUUMVACUUM SLIDEWASTE ANESTHESIA GAS DISPOSAL4' - 0" UON5' - 6"5' - 6"226000 - MEDICAL GAS DEVICES
ZONE VALVE BOXAREA ALARM PANELNURSE CALLFIG. 308.2.1
UNOBSTRUCTED FORWARD REACH
FIG. 308.2.2
OBSTRUCTED HIGH FORWARD REACH
FIG. 308.3.1
UNOBSTRUCTED SIDE REACH
FIG. 308.3.2
OBSTRUCTED HIGH SIDE REACH
48" MAX48"15" MIN20" MAX
48" MAX25" MAX
44" MAX48" MAX15" MIN46" MAX24" MAX
34" MAX48" MAX10"34" MAXFIG 608.2.2
STANDARD ROLL-IN-TYPE SHOWER
COMPARTMENT SIZE AND CLEARANCE
FIG 608.3.2
GRAB BARS IN STANDARD ROLL-IN-
TYPE SHOWER
FIG 608.4.2
STANDARD ROLL-IN-TYPE SHOWER
CONTROL AND HANDSHOWER
LOCATION34"6" MAX
BACK WALL
6" MAX
6" MAX30" MIN60" MIN
UFAS3' - 0"BACK WALL36" MIN3' - 0"36" MIN
48" MINSEAT WALLCONTROL WALL48" MAX38" MINCONTROL
WALL
FIG 608.5.1
TRANSFER-TYPE SHOWER
CONTROLS AND HANDSHOWERS LOCATION
15" MAX
10" MAX
MAX
2' - 3"
MIN
1' - 4"MAX4' - 0"CONTROL
LOCATION
1' - 4" MAX
1' - 3" MIN
SEAT
SEAT
SEAT
5' - 0"2' - 0"3' - 0"1' - 0"1' - 0"3' - 0"
2' - 10 3/8"4' - 0"5' - 0"
FIG 608.2.1
TRANSFER-TYPE SHOWER COMPARTMENT
SIZE AND CLEARANCE
FIG. 604.4 & FIG. 604.5.1 & FIG. 604.7
WATER CLOSET HEIGHTS
9"1' - 7" MAX1' - 5" MIN2' - 10"1' - 6"3' - 3"3' - 5"
1' - 0"3' - 6"
4' - 6"MIN1' - 6"2' - 0" MIN
NOTE: REQUIRED CLEARANCE MAY
INCLUDE GRAB BARS, PAPER
DISPENSERS, SANITARY NAPKIN
RECEPTACLES, COAT HOOKS,
SHELVES, ACCESSIBLE ROUTES,
CLEAR FLOOR SPACE OF OTHER
FIXTURES AND TURNING SPACE. NO
OTHER FIXTURES OR OBSTRUCTIONS
SHALL BE WITHIN THE REQUIRED
WATER CLOSET CLEARANCE.
FIG 604.3
CLEARANCE AT WATER CLOSETS
5' -0"4' -8"PLAN VIEW
18"15" .1 1/2" MIN4' - 0"7' - 2"UON1' - 6"WALL COVERING
8' - 0" MAX7' - 6" MIN6" MINCEILING LINE
NOTE: COMBINATION FIRE
ALARM STROBE & SPEAKER
DEVICES SHALL MEET
MOUNTING REQUIREMENTS
FOR BOTH DEVICES
NOTE: REFER TO FINISH PLANS AND FINISH SCHEDULE FOR SPECIFIC PRODUCT TYPES
WALL TILE (COLOR
VARIES)TONGUE & GROOVE
WOOD SIDING/ PANELING
STRUCTURAL GLASS
CHANNEL
NOT ALL MAY APPLY
BACKPAINTED GLASS
PANELSUW
BOTTLE FILLER 3' -11"HOLT STANDARDS
DATE:
PROJECT:
OTHER:
DRAWN BY:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Architecture
Planning
Interior Design
11 12
H
I
11 12
H
I
619 West State Street
Ithaca, New York 14850
132 E. Jefferson Street
Syracuse, New York 13202
p 607 273 7600 www.holt.com
WARNING: It is a violation of New
York State Law for any person,
unless acting under the direction of
a licensed Architect, to alter this
document in any way. If a document
bearing the seal of an Architect is
altered, the altering Architect shall
affix to such document his seal and
the notation "altered by" followed by
his signature, the date of such
alteration, and a specific description
of the alteration.2/5/2021 4:49:04 PMA350
TYPICAL
MOUNTING
HEIGHTS AND
ELEVATIONS
02/05/2021
2018089
KAS Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGTYPICAL HANDRAIL ELEVATION
REVISION SCHEDULE
NAME DATE
Received by DiMarco 2/15/2021