HomeMy WebLinkAboutA301 Exterior ElevationsSD
FIRST FLOOR
100' -0"
SECOND FLOOR
114' -0"
THIRD FLOOR
128' -6"
FOURTH FLOOR
144' -0"
FIFTH FLOOR
158' -0"
E7
A401
________________________________________________
PENTHOUSE
183' -4"
B/O LOW ROOF DECK
124' -6"14'-0"14'-6"15'-6"14'-0"17'-10"7'-6"76' - 4" ± BUILDING HEIGHTT/O LOW ROOF PARAPET
125' -11"
METAL COMPOSITE MATERIAL
WALL PANELS (MCP-1)
CURTAIN WALL SYSTEM
BRICK (BRK-1)
SLOPED ROOF -HIGH
POINT
175' -9 21/32"
SLOPE OF ROOF BEYOND
T/O CURTAIN WALL
176' -4"
PARAPET -LOW POINT
179' -4"
CW5CW3
CW4
6"1' - 0"
WALL HYDRANT, REFER
TO PLUMBING DRAWINGS
CARD READER, REFER TO
ELECTRICAL DRAWINGS
RECESSED AUTOMATIC DOOR
OPERATOR PUSH PLATE, REFER
TO ELECTRICAL DRAWINGS
LIGHT FIXTURE, REFER TO
ELECTRICAL DRAWINGS
6' - 0"6' - 0"
TOTAL WALL AREA: 9876 SF
TOTAL WINDOW AREA: 2029 SF
WINDOW TO WALL AREA: 20%
W32
W33
W36 W27
W32W25 3' - 9 3/8"2' - 10 3/4" ±5 3/8"2' - 2 3/4" ±2' - 5 3/8"2' - 10 3/4" ±JOINTS TO ALIGN WITH
HORIZONTAL JOINTS IN
SOUTH ELEVATION
PREFINISHED
FASCIA (RF-2)
ALUMINUM-FRAMED
STOREFRONT WINDOW
PRECAST SILL (PS-1).BELT COURSE
ALIGN
ALIGN
ALIGN
ALIGN
PREFINISHED FASCIA (RF-1)
7 EQUAL PANELS @ 5' - 0"13 EQUAL PANELS @ 5' - 0"
STAIR 3 LANDING
146' -3"
ALIGN
1' - 2"
CONTROL JOINT
ALIGN ALIGNTOOTH MASONRY
E
13 EQUAL PANELS @ 5' - 0"
3' - 10" ± VIF
12 EQUAL PANELS @ 5' - 0"5' - 0"
ALIGN
FIRST FLOOR
100' -0"
SECOND FLOOR
114' -0"
THIRD FLOOR
128' -6"
FOURTH FLOOR
144' -0"
FIFTH FLOOR
158' -0"
PENTHOUSE
183' -4"
B/O LOW ROOF DECK
124' -6"
T/O LOW ROOF PARAPET
125' -11"
METAL COMPOSITE MATERIAL
WALL PANELS (MCP-1)
CURTAIN WALL SYSTEM
SLOPED ROOF -HIGH
POINT
175' -9 21/32"
ILLUMINATED SIGNAGE
A5
A452
________________________________________________
T/O CURTAIN WALL
176' -4"
SEE A303 FOR NON-OBLIQUE ELEVATION SEE A303 FOR NON-OBLIQUE ELEVATION
CW2
TOTAL WALL AREA: 7825.5 SF
TOTAL WINDOW AREA: 1577.5 SF
WINDOW TO WALL AREA: 20%
A652
F1
METAL COMPOSITE MATERIAL
WALL PANELS (MCP-2)
JOINTS TO ALIGN WITH
HORIZONTAL JOINTS IN EAST
AND SOUTH ELEVATIONS
METAL COMPOSITE MATERIAL
WALL PANELS (MCP-1)
CURTAIN WALL SYSTEM
PREFINISHED
FASCIA (RF-2)
METAL COMPOSITE MATERIAL
WALL PANELS (MCP-2)
4' - 2"18 EQUAL PANELS @ 5' - 0"
JOINTS TO ALIGN WITH
HORIZONTAL JOINTS IN EAST AND
WEST AND SOUTH ELEVATIONS
METAL COMPOSITE MATERIAL
WALL PANELS (MCP-1), BEYOND
ALIGN
ALIGN
ALIGN
PREFINISHED
FASCIA (RF-1)
5' - 0"7 1/2"9 EQUAL PANELS @ 5' - 0"EQ EQ 9 EQUAL PANELS @ 5' - 0"7 1/2"5' - 0"
JOINTS TO ALIGN WITH
HORIZONTAL JOINTS ABOVE
SEE A303 FOR MOCKUP AREA #2 SEE A455 FOR
MOCKUP AREA #3
A301
E1
A301A3
A301A1
A301A1
FIRST FLOOR
100' -0"
SECOND FLOOR
114' -0"
THIRD FLOOR
128' -6"
FOURTH FLOOR
144' -0"
FIFTH FLOOR
158' -0"
T/O CURTAIN WALL
176' -4"
JOINTS TO ALIGN WITH
HORIZONTAL JOINTS IN EAST
AND SOUTH ELEVATIONS
METAL COMPOSITE MATERIAL
WALL PANELS (MCP-1)
6"
DATE:
PROJECT:
OTHER:
DRAWN BY:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Architecture
Planning
Interior Design
11 12
H
I
11 12
H
I
619 West State Street
Ithaca, New York 14850
132 E. Jefferson Street
Syracuse, New York 13202
p 607 273 7600 www.holt.com
WARNING: It is a violation of New
York State Law for any person,
unless acting under the direction of
a licensed Architect, to alter this
document in any way. If a document
bearing the seal of an Architect is
altered, the altering Architect shall
affix to such document his seal and
the notation "altered by" followed by
his signature, the date of such
alteration, and a specific description
of the alteration.2/10/2021 2:36:14 PMA301
EXTERIOR
ELEVATIONS
02/05/2021
2018089
CRB, KAS Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1/8" = 1'-0"E1 WEST ELEVATION
1/8" = 1'-0"A3 NORTH ELEVATION
KEY PLAN0'2'4'8'16'
REVISION SCHEDULE
NAME DATE
1/8" = 1'-0"A1 NORTH ELEVATION - METAL PANELS
(PRINT IN COLOR)
Received by DiMarco 2/15/2021