HomeMy WebLinkAboutA252 Fifth Floor Reflected Ceiling Plan Sector 2SD
OS
M M M
F
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
OS
OS
OS
OS
SECTOR 1 SECTOR 2
LINEAR PENDANT
LIGHT FIXTURE
LINEAR SURFACE MOUNTED
LIGHT FIXTURE
LAY-IN/RECESSED
DIRECT/INDIRECT LIGHT
FIXTURES
RECESSED
LIGHT FIXTURE
RETURN AIR/ EXHAUST GRILLE
SUPPLY AIR GRILLE
PROJECTION SCREEN -
MANUAL
DATA/VIDEO PROJECTOR.
CENTER MOUNT ON
PROJECTION SCREEN
PENDANT
LIGHT FIXTURESURFACE
MOUNTED LIGHT
FIXTURES
PROJECTION SCREEN -
MOTORIZED
SURFACE MOUNTED
TRACK LIGHT FIXTURE
SPRINKLER HEAD
EXIT SIGN
SMOKE DETECTOR
OCCUPANCY SENSOR
RECESSED COVE
LIGHT FIXTURE
LAY-IN/ RECESSED
TROFFER LIGHT
FIXTURES
LAY-IN/ RECESSED
PARABOLIC LIGHT
FIXTURES
WALL WASHER
LIGHT FIXTURE
SPEAKER
WOOD PANEL CEILING
2' X 4' ACOUSTICAL
PANEL CEILING SYSTEM
LINEAR METAL CEILING
LINEAR RECESSED LIGHT
FIXTURE
(W) - WALL WASH
GYPSUM BOARD
CEILINGS AND
SOFFITS
2' X 2' ACOUSTICAL
PANEL CEILING SYSTEM
ACCESS PANEL
W
LINEAR DIFFUSER
GYPSUM BOARD
CEILINGS AND
SOFFITS
DOME SAFETY MIRROR
1'-0"CEILING HEIGHT/ MATERIAL(APC#)
FIRE ALARM STROBE
CUBICLE CURTAIN
PS
NOTE: REFER TO FINISH/MATERIAL LEGEND FOR CEILING TYPES KEYED INTO CEILING
HEIGHT/MATERIAL TAG.
RECESSED WINDOW SHADE
LINEAR GRID
MOUNTED LIGHT
FIXTURES
GEOMETRIC
ACOUSTICAL PANEL
CEILING SYSTEM
2' X 4' CLEANROOM
ACOUSTICAL PANEL
CEILING SYSTEM
WOOD SIDINGACCESSIBLE WOOD
CEILING
OPEN
511
CENTRAL
SOILED WORK
517B
NURSE WORK
AREA
517A
PROVIDER
OFFICE
506
SPECIALTY
EXAM/
TREATMENT
507
EXAM/CONSULT
508
EXAM/CONSULT
509
EXAM/CONSULT
510
PATIENT VITALS
ALCOVE
504
CIRCULATION
500EA
ELEV A
500EB
ELEV B
517
STAFF
CIRCULATION
517C
CIRCULATION
517D
CIRCULATION
500
ELEVATOR
CONTROL ROOM
ST1-5
STAIR 1
501A
PUBLIC TOILET
501B
PUBLIC TOILET
501
GUEST WAITING/
CIRCULATION
505A
STAFF TOILET
503
PATIENT TOILET
ST3-5
STAIR 3
505
STAFF BREAK
AREA
504A
STAIR
VESTIBULE
9' -4"
11' -9"
APC2
9' -6"
APC1
9' -6"
LAP1
10' -6"
9' -3"
APC1
9' -6"
APC1
9' -6"
APC2
9' -0"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
LAP1
10' -6"
APC1
9' -6"
8' -0"
8' -0"
APC1
9' -6"
APC2
9' -0"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"SECTOR 1SECTOR 2SECTOR 2SECTOR 1F7
A561
________________________________________________
F7
A561
________________________________________________
F7
A561
________________________________________________
F7
A561
________________________________________________
D9
A561
________________________________________________
D9
A561
________________________________________________
F1
A561
SIM
________________________________________________
D9
A561
________________________________________________
8' -0"
F7
A561
________________________________________________
F1
A561
SIM
________________________________________________
F7
A561
________________________________________________
F7
A561
________________________________________________8' -0"
8' -0"
F7
A561
________________________________________________
F7
A561
________________________________________________
D9
A561
________________________________________________
D9
A561
________________________________________________
D9
A561
________________________________________________
D9
A561
________________________________________________
F1
A561
SIM
________________________________________________
F1
A561
SIM
________________________________________________
F1
A561
SIM
________________________________________________
D9
A561
________________________________________________
9' -4"
F1
A561
SIM
________________________________________________
F1
A561
SIM
________________________________________________F1
A561
SIM
________________________________________________
7' -2"
F7
A561
________________________________________________
D9
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
D9
A561
________________________________________________
D9
A561
________________________________________________
F7
A561
________________________________________________
F7
A561
________________________________________________
F7
A561
________________________________________________
7' -2"
7' -2"7' -2"
F7
A561
________________________________________________
F7
A561
________________________________________________F7
A561
________________________________________________
9' -4"
F1
A561
SIM
________________________________________________
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
APC2
9' -6"
D9
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
D11
A561
________________________________________________
9' -4"ALIGNALIGN4 7/8"ALIGN ALIGN
2' - 5"1' - 0"1 1 ' - 0 "
EQ EQEQ
EQ1' - 0"ALIGNALIGNEQ EQ
EQEQALIGNALIGN 3' - 11 1/2"10 1/4"ALIGNALIGN
ALIGNALIGNALIGNALIGN2' - 6"EQEQEQEQEQEQEQEQ
EQEQALIGNALIGNALIGN2' - 6"7' - 7 3/4"EQ EQ EQ EQ EQ EQ
ALIGNEQ1' - 6"
2' - 2"1' - 6"2' - 6"3' - 5"1' - 8"2' - 9"1' - 3"3' - 4"2' - 2"1' - 8"1' - 6"3' - 9"1' - 11"1' - 3"5' - 0"7"2' - 7"4' - 11"3' - 1"2' - 7"5 1/2"P15
P15
SIDES
P15P15SIDESP15P15SIDESP15P15SIDESP15 P15
SIDESP15P15P15P15SIDESP15SIDESP15SIDESP15
P15
SIDES P15P15SIDESP15
P15
SIDES
P15
SIDES
P15P15
P15
P15
P15
P15
SIDES
P15
SIDES
P14
P14
SIDES 6"4' - 6"7 1/2"9 EQUAL PANELS @ 5' - 0"EQEQ9 EQUAL PANELS @ 5' - 0"7 1/2"4' - 6"6"ALIGN
ALIGN
ALIGN
ALIGN
12 EQUAL PANELS @ 5' - 0"
4' - 6"6"
12 EQUAL PANELS @ 5' - 0"4' - 6"6"
P15
SIDES
---
-
A461
F7
EQ EQ
EQEQ9' -6"
ALIGN ALIGN
F7
A561
________________________________________________
SIM
P18
9' -4"
GYP. BD.
9' -6"
P18
CJ
1' - 0"
P18
P18
P18
ALIGN JOINTS WITH VERTICAL
JOINTS ABOVE IN EAST ELEVATION
3' - 10" ± VIF
3' - 10" ± VIF
ALIGN JOINTS WITH VERTICAL
JOINTS ABOVE IN WEST ELEVATION
ALIGN JOINTS WITH VERTICAL JOINTS
ABOVE IN NORTH ELEVATION
METAL COMPOSITE MATERIAL
WALL PANELS (MCP-1)
DATE:
PROJECT:
OTHER:
DRAWN BY:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Architecture
Planning
Interior Design
11 12
H
I
11 12
H
I
619 West State Street
Ithaca, New York 14850
132 E. Jefferson Street
Syracuse, New York 13202
p 607 273 7600 www.holt.com
WARNING: It is a violation of New
York State Law for any person,
unless acting under the direction of
a licensed Architect, to alter this
document in any way. If a document
bearing the seal of an Architect is
altered, the altering Architect shall
affix to such document his seal and
the notation "altered by" followed by
his signature, the date of such
alteration, and a specific description
of the alteration.2/5/2021 4:48:15 PMA252
FIFTH FLOOR
REFLECTED
CEILING PLAN -
SECTOR 2
02/05/2021
2018089
KAS, HRT Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGGENERAL REFLECTED CEILING PLAN NOTES
CEILING MATERIALS
KEY PLAN
LIGHT FIXTURES
0'1'2'4'8'
OTHER
KEYED REFLECTED CEILING PLAN NOTES #
1/4" = 1'-0"A1 FIFTH FLOOR REFLECTED CEILING PLAN - SECTOR 2
1 CENTER ACOUSTIC CEILING PANELS WITHIN FIELD UNLESS OTHERWISE NOTED.
PARTIAL PANELS AT ROOM PERIMETER SHALL NOT BE LESS THAN 6".
2 THE EDGE OF ALL CUT TEGULAR PANELS SHALL BE FIELD SHAPED AND PAINTED TO
MATCH FABRICATED TEGULAR EDGE. THE CUT EDGE OF ALL PANELS SHALL BE
POSITIONED OUT OF VIEW.
3 MOUNT ALL FIXTURES AND DEVICES IN THE CENTER OF ACOUSTIC CEILING PANEL
UNLESS OTHERWISE NOTED.
4 REFER TO MECHANICAL, ELECTRICAL, FIRE ALARM AND FIRE PROTECTION DRAWINGS
FOR FIXTURES NOT SHOWN ON THIS SHEET. COORDINATE LOCATIONS OF FIXTURES
NOT SHOWN WITH LAYOUT INDICATED ON THIS SHEET.
5 PROVIDE ACCESS PANELS IN ALL NON-ACCESSIBLE CEILINGS WHERE SERVICE OR
ADJUSTMENT TO MECHANICAL, PLUMBING OR ELECTRICAL ITEMS MAY BE REQUIRED.
ACCESS PANELS SHALL BE EQUAL TO THE RATING OF THE WALL OR CEILING IN WHICH
THEY OCCUR. PROVIDE COORDINATED SHOP DRAWING OF ALL REQUIRED ACCESS
PANELS FOR REVIEW.
6 PROVIDE COORDINATION DRAWINGS OF ALL EXPOSED MECHANICAL, ELECTRICAL,
PLUMBING, FIRE PROTECTION, AND AUDIO/VIDEO SYSTEMS FOR REVIEW.
7 ALL GYPSUM BOARD CEILINGS TO BE PAINTED P18 UNLESS OTHERWISE NOTED.
8 PAINT CEILING ACCESS PANELS AND MECHANICAL GRILLES / DIFFUSERS WHERE THEY
OCCUR IN GYPSUM BOARD CEILINGS TO MATCH ADJACENT CEILING FINISH.
1 COORDINATE WITH OWNER FOR SPECIALTY BLACKLIGHT PAINT FINISHES TO BE
INSTALLED IN THIS ROOM BY SEPARATE VENDOR.
2 NO CEILING.
3 X-RAY STATIONARY RAIL CROSS-MEMBERS. REFER TO STRUCTURAL FOR FURTHER
INFORMATION.
4 CEILING HEIGHT NOTED FROM ELEVATION ABOVE ROOF LEVEL
REVISION SCHEDULE
NAME DATE
Received by DiMarco 2/15/2021