HomeMy WebLinkAboutA251 Fifth Floor Reflected Ceiling Plan Sector 1SD
OS
M M M
F
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
OS
OS
OS
OS
OS
OS
OS
LINEAR PENDANT
LIGHT FIXTURE
LINEAR SURFACE MOUNTED
LIGHT FIXTURE
LAY-IN/RECESSED
DIRECT/INDIRECT LIGHT
FIXTURES
RECESSED
LIGHT FIXTURE
RETURN AIR/ EXHAUST GRILLE
SUPPLY AIR GRILLE
PROJECTION SCREEN -
MANUAL
DATA/VIDEO PROJECTOR.
CENTER MOUNT ON
PROJECTION SCREEN
PENDANT
LIGHT FIXTURESURFACE
MOUNTED LIGHT
FIXTURES
PROJECTION SCREEN -
MOTORIZED
SURFACE MOUNTED
TRACK LIGHT FIXTURE
SPRINKLER HEAD
EXIT SIGN
SMOKE DETECTOR
OCCUPANCY SENSOR
RECESSED COVE
LIGHT FIXTURE
LAY-IN/ RECESSED
TROFFER LIGHT
FIXTURES
LAY-IN/ RECESSED
PARABOLIC LIGHT
FIXTURES
WALL WASHER
LIGHT FIXTURE
SPEAKER
WOOD PANEL CEILING
2' X 4' ACOUSTICAL
PANEL CEILING SYSTEM
LINEAR METAL CEILING
LINEAR RECESSED LIGHT
FIXTURE
(W) - WALL WASH
GYPSUM BOARD
CEILINGS AND
SOFFITS
2' X 2' ACOUSTICAL
PANEL CEILING SYSTEM
ACCESS PANEL
W
LINEAR DIFFUSER
GYPSUM BOARD
CEILINGS AND
SOFFITS
DOME SAFETY MIRROR
1'-0"CEILING HEIGHT/ MATERIAL(APC#)
FIRE ALARM STROBE
CUBICLE CURTAIN
PS
NOTE: REFER TO FINISH/MATERIAL LEGEND FOR CEILING TYPES KEYED INTO CEILING
HEIGHT/MATERIAL TAG.
RECESSED WINDOW SHADE
LINEAR GRID
MOUNTED LIGHT
FIXTURES
GEOMETRIC
ACOUSTICAL PANEL
CEILING SYSTEM
2' X 4' CLEANROOM
ACOUSTICAL PANEL
CEILING SYSTEM
WOOD SIDINGACCESSIBLE WOOD
CEILING
SECTOR 1 SECTOR 2
OPEN
522
EXAM/CONSULT
521
EXAM/CONSULT
520
EXAM/CONSULT
519
EXAM/CONSULT
518
EXAM/CONSULT
517E
NURSE WORK
AREA
517F
PROVIDER
OFFICE
523
IT/ELEC
524
TRIAGE NURSE
526A
PATIENT TOILET 525
STAFF TOILET
526
SPECIALTY
EXAM/
TREATMENT
527
PATIENT TOILET
504
CIRCULATION
517
STAFF
CIRCULATION
504BB
CIRCULATION
514
EXAM/CONSULT
513
EXAM/CONSULT
512
CENTRAL CLEAN
WORK
515
EXAM/CONSULT
516
EXAM/CONSULT
533
SPECIMEN
COLLECTION532
LAB DRAW
530
EVS
538
EXAM/CONSULT
531
EXAM/CONSULT529
EXAM/CONSULT
528
EXAM/CONSULT
ST2-5
STAIR 2
517C
CIRCULATION
539A
PROVIDER
OFFICE
537
EXAM/CONSULT
539B
TRIAGE NURSE
536
PATIENT TOILET
535
SPECIALTY
EXAM/TREATMENT/
TELEMED
535A
PATIENT TOILET
534
LAB 500
ELEVATOR
CONTROL ROOM
APC2
9' -6"
9' -4"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"APC2
9' -6"
APC1
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC1
9' -6"
APC2
9' -6"
APC1
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
8' -0"
APC2
9' -6"
APC1
9' -6"
10' -0"
APC2
9' -6"
8' -0"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
7' -6"
APC2
9' -0"SECTOR 1SECTOR 2SECTOR 2SECTOR 17' -2"
F7
A561
________________________________________________
7' -2"
7' -2"
F7
A561
________________________________________________
F7
A561
________________________________________________
7' -2"F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
D9
A561
________________________________________________
D9
A561
________________________________________________
7' -2"
F4
A561
________________________________________________
535B
STORAGE
D9
A561
________________________________________________
F4
A561
________________________________________________7' -2"
D9
A561
________________________________________________
F7
A561
________________________________________________
7' -2"
9' -4"
9' -4"
9' -4"
F1
A561
SIM
________________________________________________
F1
A561
SIM
________________________________________________
F1
A561
SIM
________________________________________________
F1
A561
SIM
________________________________________________
F4
A561
________________________________________________
7' -2"
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
539C
STORAGE
F7
A561
________________________________________________
8' -0"
F7
A561
________________________________________________
APC2
7' -2"
D9
A561
________________________________________________
7' -2"
F4
A561
________________________________________________
D9
A561
________________________________________________
D9
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
7' -2"
F7
A561
________________________________________________
F7
A561
________________________________________________
7' -2"F4
A561
________________________________________________
7' -2"
F10
A561
________________________________________________
F4
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
F7
A561
________________________________________________
9' -4"F1
A561
SIM
________________________________________________
ALIGN
EQ EQEQEQ
1' - 0"ALIGNALIGNEQEQEQ 6' - 0"EQ
ALIGNALIGNEQ EQ
EQ5' - 8"EQALIGNALIGNALIGNALIGN4 7/8"EQ EQ 4 7/8"EQ3' - 6"3' - 6"EQ2' - 6"4 7/8"2' - 6 1/4"4 7/8"ALIGN4 7/8"EQ EQEQ
EQ2' - 2"1' - 6"1' - 11"P15 P15
SIDES
P15 P15
SIDES
P15P15SIDESP15P15SIDESP15P15SIDESP15P15SIDESP15P15SIDES P15
SIDES
P15
SIDES
P15SIDESP15SIDESP15P15SIDESP15P15SIDESP15P15
SIDES
P15P15SIDESP15P15SIDESP15P15P15P15P15SIDESP15P15
SIDES
P15
P15SIDESP15SIDESP15SIDES13 EQUAL PANELS @ 5' - 0"
2
9' -4"
ALIGN
9' -6"
ALIGN
F7
A561
________________________________________________
SIM
9' -6"
ALIGN
9' -6"
F7
A561
________________________________________________
SIM
F7
A561
________________________________________________
SIM
P18
P18
APC2
7' -11"4
6"6"P2P2
SIDESP2
P2
SIDES
P2P2
SIDES P2P2
SIDES
P15
P15SIDESP2
SIDESP2
P18
P2P2P2
SIDESP2SIDES P2P2SIDES6"
JOINTS TO ALIGN WITH VERTICAL
JOINTS AT SOUTH ELEVATION
2' - 0"
ALIGN JOINTS WITH VERTICAL
JOINTS ABOVE IN EAST ELEVATION
13 EQUAL PANELS @ 5' - 0"
ALIGN JOINTS WITH VERTICAL
JOINTS ABOVE IN WEST ELEVATION
2' - 0"
5' - 7 1/2" ± VIF
METAL COMPOSITE MATERIAL
WALL PANELS (MCP-1)
METAL COMPOSITE MATERIAL
WALL PANELS (MCP-1)
METAL COMPOSITE MATERIAL
WALL PANELS (MCP-1)
SLOPED WALL ABOVE
GYP. BD.
5' -9"
GYPSUM BOARD
AT STRUCTURAL
FRAMING
FINISHED FACE OF GYPSUM
BOARD TO ALIGN WITH
BOTTOM OF STEEL BEAM
STEEL PLATE AND BEAM
ABOVE WITH INTUMESCENT
FIREPROOFING AND
PAINTED FINISH
GYP. BD.
12' -4"
FINISHED FACE OF GYPSUM
BOARD TO ALIGN WITH
BOTTOM OF STEEL PLATE
± (VIF)
DATE:
PROJECT:
OTHER:
DRAWN BY:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Architecture
Planning
Interior Design
11 12
H
I
11 12
H
I
619 West State Street
Ithaca, New York 14850
132 E. Jefferson Street
Syracuse, New York 13202
p 607 273 7600 www.holt.com
WARNING: It is a violation of New
York State Law for any person,
unless acting under the direction of
a licensed Architect, to alter this
document in any way. If a document
bearing the seal of an Architect is
altered, the altering Architect shall
affix to such document his seal and
the notation "altered by" followed by
his signature, the date of such
alteration, and a specific description
of the alteration.2/5/2021 5:19:54 PMA251
FIFTH FLOOR
REFLECTED
CEILING PLAN -
SECTOR 1
02/05/2021
2018089
CRB, KAS, HRT Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGGENERAL REFLECTED CEILING PLAN NOTES
CEILING MATERIALS
KEY PLAN
LIGHT FIXTURES
0'1'2'4'8'
OTHER
KEYED REFLECTED CEILING PLAN NOTES #
1/4" = 1'-0"A1 FIFTH FLOOR REFLECTED CEILING PLAN - SECTOR 1
1 CENTER ACOUSTIC CEILING PANELS WITHIN FIELD UNLESS OTHERWISE NOTED.
PARTIAL PANELS AT ROOM PERIMETER SHALL NOT BE LESS THAN 6".
2 THE EDGE OF ALL CUT TEGULAR PANELS SHALL BE FIELD SHAPED AND PAINTED TO
MATCH FABRICATED TEGULAR EDGE. THE CUT EDGE OF ALL PANELS SHALL BE
POSITIONED OUT OF VIEW.
3 MOUNT ALL FIXTURES AND DEVICES IN THE CENTER OF ACOUSTIC CEILING PANEL
UNLESS OTHERWISE NOTED.
4 REFER TO MECHANICAL, ELECTRICAL, FIRE ALARM AND FIRE PROTECTION DRAWINGS
FOR FIXTURES NOT SHOWN ON THIS SHEET. COORDINATE LOCATIONS OF FIXTURES
NOT SHOWN WITH LAYOUT INDICATED ON THIS SHEET.
5 PROVIDE ACCESS PANELS IN ALL NON-ACCESSIBLE CEILINGS WHERE SERVICE OR
ADJUSTMENT TO MECHANICAL, PLUMBING OR ELECTRICAL ITEMS MAY BE REQUIRED.
ACCESS PANELS SHALL BE EQUAL TO THE RATING OF THE WALL OR CEILING IN WHICH
THEY OCCUR. PROVIDE COORDINATED SHOP DRAWING OF ALL REQUIRED ACCESS
PANELS FOR REVIEW.
6 PROVIDE COORDINATION DRAWINGS OF ALL EXPOSED MECHANICAL, ELECTRICAL,
PLUMBING, FIRE PROTECTION, AND AUDIO/VIDEO SYSTEMS FOR REVIEW.
7 ALL GYPSUM BOARD CEILINGS TO BE PAINTED P18 UNLESS OTHERWISE NOTED.
8 PAINT CEILING ACCESS PANELS AND MECHANICAL GRILLES / DIFFUSERS WHERE THEY
OCCUR IN GYPSUM BOARD CEILINGS TO MATCH ADJACENT CEILING FINISH.
1 COORDINATE WITH OWNER FOR SPECIALTY BLACKLIGHT PAINT FINISHES TO BE
INSTALLED IN THIS ROOM BY SEPARATE VENDOR.
2 NO CEILING.
3 X-RAY STATIONARY RAIL CROSS-MEMBERS. REFER TO STRUCTURAL FOR FURTHER
INFORMATION.
4 CEILING HEIGHT NOTED FROM ELEVATION ABOVE ROOF LEVEL
REVISION SCHEDULE
NAME DATE
Received by DiMarco 2/15/2021