HomeMy WebLinkAboutA231 Third Floor Reflected Ceiling Plan Sector 1SD
OS
M M M
F
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
OS
OS
OS
OS
OS
LINEAR PENDANT
LIGHT FIXTURE
LINEAR SURFACE MOUNTED
LIGHT FIXTURE
LAY-IN/RECESSED
DIRECT/INDIRECT LIGHT
FIXTURES
RECESSED
LIGHT FIXTURE
RETURN AIR/ EXHAUST GRILLE
SUPPLY AIR GRILLE
PROJECTION SCREEN -
MANUAL
DATA/VIDEO PROJECTOR.
CENTER MOUNT ON
PROJECTION SCREEN
PENDANT
LIGHT FIXTURESURFACE
MOUNTED LIGHT
FIXTURES
PROJECTION SCREEN -
MOTORIZED
SURFACE MOUNTED
TRACK LIGHT FIXTURE
SPRINKLER HEAD
EXIT SIGN
SMOKE DETECTOR
OCCUPANCY SENSOR
RECESSED COVE
LIGHT FIXTURE
LAY-IN/ RECESSED
TROFFER LIGHT
FIXTURES
LAY-IN/ RECESSED
PARABOLIC LIGHT
FIXTURES
WALL WASHER
LIGHT FIXTURE
SPEAKER
WOOD PANEL CEILING
2' X 4' ACOUSTICAL
PANEL CEILING SYSTEM
LINEAR METAL CEILING
LINEAR RECESSED LIGHT
FIXTURE
(W) - WALL WASH
GYPSUM BOARD
CEILINGS AND
SOFFITS
2' X 2' ACOUSTICAL
PANEL CEILING SYSTEM
ACCESS PANEL
W
LINEAR DIFFUSER
GYPSUM BOARD
CEILINGS AND
SOFFITS
DOME SAFETY MIRROR
1'-0"CEILING HEIGHT/ MATERIAL(APC#)
FIRE ALARM STROBE
CUBICLE CURTAIN
PS
NOTE: REFER TO FINISH/MATERIAL LEGEND FOR CEILING TYPES KEYED INTO CEILING
HEIGHT/MATERIAL TAG.
RECESSED WINDOW SHADE
LINEAR GRID
MOUNTED LIGHT
FIXTURES
GEOMETRIC
ACOUSTICAL PANEL
CEILING SYSTEM
2' X 4' CLEANROOM
ACOUSTICAL PANEL
CEILING SYSTEM
WOOD SIDINGACCESSIBLE WOOD
CEILING
SECTOR 1 SECTOR 2
323
ELEC/ DATA
ST2-3
STAIR 2
335A
PATIENT TOILET
322
EXAM/CONSULT
312
CENTRAL CLEAN
WORK
313
EXAM/CONSULT
314
EXAM/CONSULT
315
EXAM/CONSULT
316
EXAM/CONSULT
318
EXAM/CONSULT
319
EXAM/CONSULT
320
EXAM/CONSULT
321
EXAM/CONSULT
317
STAFF
CIRCULATION
326
SPECIALTY
EXAM/
TREATMENT
327
PATIENT TOILET
317F
PROVIDER
OFFICE
326A
PATIENT TOILET
325
STAFF TOILET
324
TRIAGE NURSE
317E
NURSE WORK
AREA
328
EXAM/CONSULT
331
EXAM/CONSULT
329
EXAM/CONSULT
329.1
EXAM/CONSULT
339B
TRIAGE NURSE
327
EXAM/CONSULT
330
EVS
339A
PROVIDER
OFFICE
339
NURSE WORK
333
SPECIMEN
COLLECTION332
LAB DRAW
334
LAB
335
SPECIALTY
EXAM/TREATMENT/
TELEMED336
PATIENT TOILET
APC2
9' -6"
9' -4"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC1
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC1
9' -6"
APC2
9' -6"
APC1
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
8' -0"
APC2
9' -6"
APC1
9' -6"
10' -0"
APC2
9' -6"
8' -0"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
9' -6"
APC2
7' -2"
APC2
9' -6"
APC2
7' -6"
APC2
9' -0"
APC2
9' -6"SECTOR 1SECTOR 2SECTOR 2SECTOR 1F7
A561
________________________________________________
7' -2"F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
D9
A561
________________________________________________
7' -2"
F4
A561
________________________________________________
8' -0"
F7
A561
________________________________________________
F7
A561
________________________________________________
D9
A561
________________________________________________
D9
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
APC2
9' -6"
F10
A561
________________________________________________
F7
A561
________________________________________________
7' -2"
7' -2"
F7
A561
________________________________________________
F7
A561
________________________________________________
7' -2"F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
D9
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
D9
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F4
A561
________________________________________________
D9
A561
________________________________________________
F4
A561
________________________________________________7' -2"
D9
A561
________________________________________________
F7
A561
________________________________________________
7' -2"
9' -4"9' -4"
9' -4"
9' -4"F1
A561
SIM
________________________________________________
F1
A561
SIM
________________________________________________
F1
A561
SIM
________________________________________________
F1
A561
SIM
________________________________________________
F4
A561
________________________________________________
7' -2"
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
7' -2"
F7
A561
________________________________________________
350
STORAGE
7' -2"
7' -2"
F7
A561
________________________________________________
F7
A561
________________________________________________ALIGNALIGNALIGNALIGN4 7/8"EQ EQ 4 7/8"2' - 6"4 7/8"2' - 6 1/4"4 7/8"EQ3' - 6"3' - 6"EQ1' - 0"ALIGNALIGNEQEQEQ 6' - 0"EQ ALIGNALIGN
EQ EQEQEQ
ALIGNALIGNEQ EQ
EQ5' - 8"EQP10 P10
SIDES
P10 P10
SIDES
P10P10SIDESP10P10SIDESP10P10SIDESP10
P10P10SIDESP10
SIDES
P10
SIDES
P10SIDESP10SIDESP10P10SIDESP10P10SIDESP10P10
SIDES
P10
P10SIDESP10P10SIDESP10P10SIDESP10P10P10P10P10P10
SIDES P10P10SIDESP10SIDESP10SIDESP10SIDESP10SIDES7' -4"7' -2"
2
2
ALIGN
9' -6"P18
F7
A561
________________________________________________
SIM
ALIGN
9' -6"P18
F7
A561
________________________________________________
SIM ALIGN
9' -6"
F7
A561
________________________________________________
SIM
P18
ALIGN
P2P2
SIDESP2
P2
SIDES
P2P2
SIDES P2P2
SIDES
P2
SIDES
P2P2P2P2SIDES P2P2SIDESGYP. BD.
13' -3"
ALIGN
ALUMINUM
TRIM
OPEN TO
ABOVE
PROVIDE FINSHED 5/8"
GYPSUM BOARD WHERE
BACK SIDE OF TUBE IS
EXPOSED. REFER ALSO
TO F10/A503
DATE:
PROJECT:
OTHER:
DRAWN BY:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Architecture
Planning
Interior Design
11 12
H
I
11 12
H
I
619 West State Street
Ithaca, New York 14850
132 E. Jefferson Street
Syracuse, New York 13202
p 607 273 7600 www.holt.com
WARNING: It is a violation of New
York State Law for any person,
unless acting under the direction of
a licensed Architect, to alter this
document in any way. If a document
bearing the seal of an Architect is
altered, the altering Architect shall
affix to such document his seal and
the notation "altered by" followed by
his signature, the date of such
alteration, and a specific description
of the alteration.2/11/2021 3:32:21 PMA231
THIRD FLOOR
REFLECTED
CEILING PLAN -
SECTOR 1
02/05/2021
2018089
CRB, KAS, HRT Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGGENERAL REFLECTED CEILING PLAN NOTES
CEILING MATERIALS
KEY PLAN
LIGHT FIXTURES
0'1'2'4'8'
OTHER
KEYED REFLECTED CEILING PLAN NOTES #
1/4" = 1'-0"A1 THIRD FLOOR - REFLECTED CEILING PLAN - SECTOR 1
1 CENTER ACOUSTIC CEILING PANELS WITHIN FIELD UNLESS OTHERWISE NOTED.
PARTIAL PANELS AT ROOM PERIMETER SHALL NOT BE LESS THAN 6".
2 THE EDGE OF ALL CUT TEGULAR PANELS SHALL BE FIELD SHAPED AND PAINTED TO
MATCH FABRICATED TEGULAR EDGE. THE CUT EDGE OF ALL PANELS SHALL BE
POSITIONED OUT OF VIEW.
3 MOUNT ALL FIXTURES AND DEVICES IN THE CENTER OF ACOUSTIC CEILING PANEL
UNLESS OTHERWISE NOTED.
4 REFER TO MECHANICAL, ELECTRICAL, FIRE ALARM AND FIRE PROTECTION DRAWINGS
FOR FIXTURES NOT SHOWN ON THIS SHEET. COORDINATE LOCATIONS OF FIXTURES
NOT SHOWN WITH LAYOUT INDICATED ON THIS SHEET.
5 PROVIDE ACCESS PANELS IN ALL NON-ACCESSIBLE CEILINGS WHERE SERVICE OR
ADJUSTMENT TO MECHANICAL, PLUMBING OR ELECTRICAL ITEMS MAY BE REQUIRED.
ACCESS PANELS SHALL BE EQUAL TO THE RATING OF THE WALL OR CEILING IN WHICH
THEY OCCUR. PROVIDE COORDINATED SHOP DRAWING OF ALL REQUIRED ACCESS
PANELS FOR REVIEW.
6 PROVIDE COORDINATION DRAWINGS OF ALL EXPOSED MECHANICAL, ELECTRICAL,
PLUMBING, FIRE PROTECTION, AND AUDIO/VIDEO SYSTEMS FOR REVIEW.
7 ALL GYPSUM BOARD CEILINGS TO BE PAINTED P18 UNLESS OTHERWISE NOTED.
8 PAINT CEILING ACCESS PANELS AND MECHANICAL GRILLES / DIFFUSERS WHERE THEY
OCCUR IN GYPSUM BOARD CEILINGS TO MATCH ADJACENT CEILING FINISH.
1 COORDINATE WITH OWNER FOR SPECIALTY BLACKLIGHT PAINT FINISHES TO BE
INSTALLED IN THIS ROOM BY SEPARATE VENDOR.
2 NO CEILING.
3 X-RAY STATIONARY RAIL CROSS-MEMBERS. REFER TO STRUCTURAL FOR FURTHER
INFORMATION.
4 CEILING HEIGHT NOTED FROM ELEVATION ABOVE ROOF LEVEL
REVISION SCHEDULE
NAME DATE
Received by DiMarco 2/15/2021