Loading...
HomeMy WebLinkAboutA222 Second Floor Reflected Ceiling Plan Sector 2SD OS M M M F SD SD SD SD SD SD SD SD SD SD SD SD SD SD OS OS OS OS OS OS OS OS SECTOR 1 SECTOR 2 SECTOR 3 LINEAR PENDANT LIGHT FIXTURE LINEAR SURFACE MOUNTED LIGHT FIXTURE LAY-IN/RECESSED DIRECT/INDIRECT LIGHT FIXTURES RECESSED LIGHT FIXTURE RETURN AIR/ EXHAUST GRILLE SUPPLY AIR GRILLE PROJECTION SCREEN - MANUAL DATA/VIDEO PROJECTOR. CENTER MOUNT ON PROJECTION SCREEN PENDANT LIGHT FIXTURESURFACE MOUNTED LIGHT FIXTURES PROJECTION SCREEN - MOTORIZED SURFACE MOUNTED TRACK LIGHT FIXTURE SPRINKLER HEAD EXIT SIGN SMOKE DETECTOR OCCUPANCY SENSOR RECESSED COVE LIGHT FIXTURE LAY-IN/ RECESSED TROFFER LIGHT FIXTURES LAY-IN/ RECESSED PARABOLIC LIGHT FIXTURES WALL WASHER LIGHT FIXTURE SPEAKER WOOD PANEL CEILING 2' X 4' ACOUSTICAL PANEL CEILING SYSTEM LINEAR METAL CEILING LINEAR RECESSED LIGHT FIXTURE (W) - WALL WASH GYPSUM BOARD CEILINGS AND SOFFITS 2' X 2' ACOUSTICAL PANEL CEILING SYSTEM ACCESS PANEL W LINEAR DIFFUSER GYPSUM BOARD CEILINGS AND SOFFITS DOME SAFETY MIRROR 1'-0"CEILING HEIGHT/ MATERIAL(APC#) FIRE ALARM STROBE CUBICLE CURTAIN PS NOTE: REFER TO FINISH/MATERIAL LEGEND FOR CEILING TYPES KEYED INTO CEILING HEIGHT/MATERIAL TAG. RECESSED WINDOW SHADE LINEAR GRID MOUNTED LIGHT FIXTURES GEOMETRIC ACOUSTICAL PANEL CEILING SYSTEM 2' X 4' CLEANROOM ACOUSTICAL PANEL CEILING SYSTEM WOOD SIDINGACCESSIBLE WOOD CEILING APC2 9' -6" APC2 9' -6" APC2 9' -6" APC2 9' -6" APC2 9' -6" APC2 9' -6" APC2 9' -6" APC2 9' -6" APC2 9' -6" APC2 9' -6"APC2 9' -6" APC2 9' -6"APC1 9' -6" APC2 8' -0" APC1 8' -0" APC2 8' -0" APC2 9' -0" APC2 9' -0" 200A PUBLIC TOILET 200EB ELEV B200EA ELEV A 200B PUBLIC TOILET 221 LAB 215 EXAM 216 EXAM 217 EXAM 233 TELMED APC2 9' -6" APC1 9' -6" 10' -0" LAP1 10' -6" APC2 8' -0" APC2 8' -0" APC2 9' -6" APC2 9' -6"9' -4" 9' -4" APC2 9' -6" APC2 9' -6" 9' -4" 7' -2" APC2 9' -6"8' -0" APC2 8' -0" 213 PHYSICIAN OFFICE/ DICTATION 212 EXAM 210 EXAM 209 MANAGER OFFICE 208 SHARED STAFF BREAK 201 WAITING 202 SHARED RECEPTION/ REGISTRATION 207 CIRCULATION 203 SHARED CLERICAL OFFICE 204 MULTIPURPOSE/ CONSULT/ TELEMED 205 STAFF TOILET 206 SHARED MULTIPURPOSE/ CONSULT/ TELEMED 214 NURSE 218 EXAM (GYN) 219 SHARED CLEAN WORK/ MED PREP 220 EXAM (GYN) PoS 222 PATIENT TOILET 224 VISITOR TOILET (PoS) 225 DENTAL TREATMENT ROOM 229 SHARED SOILED HOLDING 226 EVS 228 CIRCULATION 227 DENTAL EQUIPMENT STERILIZATION 231 SHARED EQUIPMENT STORAGE 223 VITALS ALCOVE 230 DENTAL OFFICE APC2 9' -6" APC2 8' -0"SECTOR 2SECTOR 1S E C T O R 2SECTOR 3 F7 A561 ________________________________________________ F7 A561 ________________________________________________ F7 A561 ________________________________________________ 7' -2" F7 A561 ________________________________________________ F7 A561 ________________________________________________ 7' -2" 7' -2" F4 A561 ________________________________________________ 7' -2" 7' -2" F4 A561 ________________________________________________ F4 A561 ________________________________________________ F7 A561 ________________________________________________ F7 A561 ________________________________________________ F7 A561 ________________________________________________ 7' -2"7' -2"7' -2" 7' -2" F7 A561 ________________________________________________ 7' -2" F7 A561 ________________________________________________ 7' -2" 7' -2" F7 A561 ________________________________________________ F7 A561 ________________________________________________ F1 A561 SIM ________________________________________________ H10 A561 ________________________________________________ ALIGN A L IG N 7' -2" F7 A561 ________________________________________________ 7' -2" F7 A561 ________________________________________________ 7' -2" F7 A561 ________________________________________________ 7' -2" F7 A561 ________________________________________________ A L IG N ALIGN F7 A561 ________________________________________________ D9 A561 ________________________________________________ D9 A561 ________________________________________________ 9' -4" A L IG N F7 A561 ________________________________________________ 9' -4" F7 A561 ________________________________________________ALI GN7' -2" F7 A561 ________________________________________________ 7' -2" F7 A561 ________________________________________________ APC2 9' -0" APC2 9' -0" APC2 9' -6" APC2 9' -6" D9 A561 ________________________________________________ D9 A561 ________________________________________________ GYP. BD. 7' -10" D9 A561 ________________________________________________ D9 A561 ________________________________________________ 7' -2" F7 A561 ________________________________________________ F1 A561 SIM ________________________________________________ F7 A561 ________________________________________________ F1 A561 SIM ________________________________________________ F1 A561 SIM ________________________________________________D9 A561 ________________________________________________ F1 A561 SIM ________________________________________________ F7 A561 ________________________________________________ F7 A561 ________________________________________________ 7' -2" 7' -2" 7' -2" F7 A561 ________________________________________________ F7 A561 ________________________________________________ D9 A561 ________________________________________________ D9 A561 ________________________________________________ 9' -4" F1 A561 SIM ________________________________________________ 9' -4" D5 A561 ________________________________________________5 1/2"ALIGN ALIGNALIGNALIGNEQEQ3' - 5"2' - 6"3' - 3"3' - 3"EQEQ3' - 6" 1 ' - 1 0 "3' - 2"3' - 2"EQEQ1 ' - 1 1 "1 ' - 1 1 "EQ6' - 7"EQE Q E Q ALIGN A L IG NALIGN5 1 /2 "5 1/ 2 "5 1 /2" 6 ' - 4 3/ 8 "4' - 11"EQEQEQ 2' - 6" E Q 2' - 6"E Q E Q SIM EQ EQEQ EQEQ8' -0" 8' -0" EQ D9 A561 ________________________________________________ P8 P 8 P 8 P8 SIDES P 8 P 8 S ID E S P8 SIDES P8 SIDES P8 P 8 P 8 S ID E S P8 P 8 P8 SIDES P 8 S ID E S P 8 P 8 S ID E S P8 P8 P 8 P 8 S ID E SP8 S ID E SP8 S ID E S P 8 P 8 S ID E S P 8 P 8 S ID E S P8 P 8 S ID E S P 8 S ID E S P8P8P8 SIDES P8 SIDES P8P8 SIDES P8P8 SIDES P8 P8 SIDES P8 P8 SIDES P8P8P8P8P8P8 SIDES P8 SIDES P8 SIDES P8 SIDES P8 P8 SIDES P 8 S ID E S P8 1 ' - 5 7 /8 "8' -3 1/2" EXTERIOR CEILING SYSTEM 1 (CS-1) EXTERIOR CEILING SYSTEM 1 (CS-1) FUTURE OVERHEAD FIXTURE 19' - 0 9/16"3' - 0"6' - 8"ROOF HATCH DATE: PROJECT: OTHER: DRAWN BY: A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 11 12 H I 11 12 H I 619 West State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration.2/10/2021 2:35:42 PMA222 SECOND FLOOR REFLECTED CEILING PLAN - SECTOR 2 02/05/2021 2018089 KAS, HRT Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGGENERAL REFLECTED CEILING PLAN NOTES CEILING MATERIALS KEY PLAN LIGHT FIXTURES 0'1'2'4'8' OTHER KEYED REFLECTED CEILING PLAN NOTES # 1/4" = 1'-0"A2 SECOND FLOOR REFLECTED CEILING PLAN - SECTOR 2 1 CENTER ACOUSTIC CEILING PANELS WITHIN FIELD UNLESS OTHERWISE NOTED. PARTIAL PANELS AT ROOM PERIMETER SHALL NOT BE LESS THAN 6". 2 THE EDGE OF ALL CUT TEGULAR PANELS SHALL BE FIELD SHAPED AND PAINTED TO MATCH FABRICATED TEGULAR EDGE. THE CUT EDGE OF ALL PANELS SHALL BE POSITIONED OUT OF VIEW. 3 MOUNT ALL FIXTURES AND DEVICES IN THE CENTER OF ACOUSTIC CEILING PANEL UNLESS OTHERWISE NOTED. 4 REFER TO MECHANICAL, ELECTRICAL, FIRE ALARM AND FIRE PROTECTION DRAWINGS FOR FIXTURES NOT SHOWN ON THIS SHEET. COORDINATE LOCATIONS OF FIXTURES NOT SHOWN WITH LAYOUT INDICATED ON THIS SHEET. 5 PROVIDE ACCESS PANELS IN ALL NON-ACCESSIBLE CEILINGS WHERE SERVICE OR ADJUSTMENT TO MECHANICAL, PLUMBING OR ELECTRICAL ITEMS MAY BE REQUIRED. ACCESS PANELS SHALL BE EQUAL TO THE RATING OF THE WALL OR CEILING IN WHICH THEY OCCUR. PROVIDE COORDINATED SHOP DRAWING OF ALL REQUIRED ACCESS PANELS FOR REVIEW. 6 PROVIDE COORDINATION DRAWINGS OF ALL EXPOSED MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION, AND AUDIO/VIDEO SYSTEMS FOR REVIEW. 7 ALL GYPSUM BOARD CEILINGS TO BE PAINTED P18 UNLESS OTHERWISE NOTED. 8 PAINT CEILING ACCESS PANELS AND MECHANICAL GRILLES / DIFFUSERS WHERE THEY OCCUR IN GYPSUM BOARD CEILINGS TO MATCH ADJACENT CEILING FINISH. 1 COORDINATE WITH OWNER FOR SPECIALTY BLACKLIGHT PAINT FINISHES TO BE INSTALLED IN THIS ROOM BY SEPARATE VENDOR. 2 NO CEILING. 3 X-RAY STATIONARY RAIL CROSS-MEMBERS. REFER TO STRUCTURAL FOR FURTHER INFORMATION. 4 CEILING HEIGHT NOTED FROM ELEVATION ABOVE ROOF LEVEL REVISION SCHEDULE NAME DATE Received by DiMarco 2/15/2021