HomeMy WebLinkAboutA213 First Floor Reflected Ceiling Plan Sector 3SD
OS
M M M
F
SD
SD
SD
SD
SD
SD
OS
SD
SD
SD
OS
SECTOR 1 SECTOR 2
SECTOR 3
LINEAR PENDANT
LIGHT FIXTURE
LINEAR SURFACE MOUNTED
LIGHT FIXTURE
LAY-IN/RECESSED
DIRECT/INDIRECT LIGHT
FIXTURES
RECESSED
LIGHT FIXTURE
RETURN AIR/ EXHAUST GRILLE
SUPPLY AIR GRILLE
PROJECTION SCREEN -
MANUAL
DATA/VIDEO PROJECTOR.
CENTER MOUNT ON
PROJECTION SCREEN
PENDANT
LIGHT FIXTURESURFACE
MOUNTED LIGHT
FIXTURES
PROJECTION SCREEN -
MOTORIZED
SURFACE MOUNTED
TRACK LIGHT FIXTURE
SPRINKLER HEAD
EXIT SIGN
SMOKE DETECTOR
OCCUPANCY SENSOR
RECESSED COVE
LIGHT FIXTURE
LAY-IN/ RECESSED
TROFFER LIGHT
FIXTURES
LAY-IN/ RECESSED
PARABOLIC LIGHT
FIXTURES
WALL WASHER
LIGHT FIXTURE
SPEAKER
WOOD PANEL CEILING
2' X 4' ACOUSTICAL
PANEL CEILING SYSTEM
LINEAR METAL CEILING
LINEAR RECESSED LIGHT
FIXTURE
(W) - WALL WASH
GYPSUM BOARD
CEILINGS AND
SOFFITS
2' X 2' ACOUSTICAL
PANEL CEILING SYSTEM
ACCESS PANEL
W
LINEAR DIFFUSER
GYPSUM BOARD
CEILINGS AND
SOFFITS
DOME SAFETY MIRROR
1'-0"CEILING HEIGHT/ MATERIAL(APC#)
FIRE ALARM STROBE
CUBICLE CURTAIN
PS
NOTE: REFER TO FINISH/MATERIAL LEGEND FOR CEILING TYPES KEYED INTO CEILING
HEIGHT/MATERIAL TAG.
RECESSED WINDOW SHADE
LINEAR GRID
MOUNTED LIGHT
FIXTURES
GEOMETRIC
ACOUSTICAL PANEL
CEILING SYSTEM
2' X 4' CLEANROOM
ACOUSTICAL PANEL
CEILING SYSTEM
WOOD SIDINGACCESSIBLE WOOD
CEILING
OPEN TO ABOVE
100
MAIN LOBBY
100V1
VESTIBULE
ST1-1
STAIR 1
APC3
10' -10"
9' -4"
LAP1
10' -6"
APC2
9' -6"
LAP1
9' -6"
10' -10"
WD1
10' -10"
APC3
10' -10"
WD1
10' -9 1/2"SECTOR 3SECTOR 1S E C T O R 2SECTOR 3
7' -2"
F7
A561
________________________________________________
F7
A561
________________________________________________
D11
A561
________________________________________________
F1
A561
SIM
________________________________________________
9' -4"
D9
A561
________________________________________________
D9
A561
________________________________________________
D11
A501
________________________________________________H3
A501
________________________________________________
F2
A455
________________________________________________
9' -6"F7
A561
________________________________________________
D9
A561
________________________________________________
D5
A561
________________________________________________
9' -4"9"5 1/2"ALIGN5 7/8"1' -
5
"1' - 11"
A4
A561
________________________________________________
D9
A561
________________________________________________
SIM
P3
P3
SIDES
P3
SIDES
P3
P3SIDESP17
SIDES
P17
SIDES
2 ' - 9 "
2 ' - 9 "
4 ' - 0 "EQEQ66°2'
-
5"5'
-
6 3/8"
A10
A468
________________________________________________
D11
A501
________________________________________________ALIGN9' -0"
4 7/8"
A L IG N
7 1/2" / 12"EQEQH1
A501
________________________________________________
1 3 E Q U AL B O AR D S
ALIGN
D2
A455
________________________________________________
F2
A455
________________________________________________AL
I
GNALI
GNALI
GNSOFFIT VENT
SOFFIT VENT
90°6°72°
SIM
A1
A501
________________________________________________
APC2
8' -0"
125
EVS
5
B
CC
6
3.9
5.5
5.6
B.3B.3
106
TRIAGE/
INTERVIEW
101
LOBBY/WAITING
101A
VISITOR TOILET
102
STAFF BREAK
1
'
- 0"6'
-
9"5' - 0"10' - 1 5/8"
1 4 ' - 4 3 1 /3 2 "8' - 2 5/8"1 3 ' - 7 3 /4 "16' - 4 1/4"12' - 4 1/4"
7' - 2 1/2"
8' - 7 3/4"
4 7/8"
1 0 ' - 2 5 /8 "10'
-
4 1/4"
1 3 ' - 8 3 /8 "10'
-
4 3/4"10' - 6"1
2' - 3 3/4"12'
-
10 7/8"6' - 1 5/8"1' - 5"1
2' -
1
1
5
/
8
"13'
- 6 3/8"
4 ' - 2 "1 ' - 0 "7 "3 ' - 9 "1' - 4"1' - 10"4' - 5"2' - 9"1' - 3"1"11"6' - 1"1"1' - 3"4"1"5"
2"1"
2' - 6"
9' -6"9' -4"
DATE:
PROJECT:
OTHER:
DRAWN BY:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Architecture
Planning
Interior Design
11 12
H
I
11 12
H
I
619 West State Street
Ithaca, New York 14850
132 E. Jefferson Street
Syracuse, New York 13202
p 607 273 7600 www.holt.com
WARNING: It is a violation of New
York State Law for any person,
unless acting under the direction of
a licensed Architect, to alter this
document in any way. If a document
bearing the seal of an Architect is
altered, the altering Architect shall
affix to such document his seal and
the notation "altered by" followed by
his signature, the date of such
alteration, and a specific description
of the alteration.2/5/2021 4:46:47 PMA213
FIRST FLOOR
REFLECTED
CEILING PLAN -
SECTOR 3
02/05/2021
2018089
KAS, HRT Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGGENERAL REFLECTED CEILING PLAN NOTES
CEILING MATERIALS
KEY PLAN
LIGHT FIXTURES
0'1'2'4'8'
OTHER
KEYED REFLECTED CEILING PLAN NOTES #
1/4" = 1'-0"A1 FIRST FLOOR REFLECTED CEILING PLAN - SECTOR 3
1 CENTER ACOUSTIC CEILING PANELS WITHIN FIELD UNLESS OTHERWISE NOTED.
PARTIAL PANELS AT ROOM PERIMETER SHALL NOT BE LESS THAN 6".
2 THE EDGE OF ALL CUT TEGULAR PANELS SHALL BE FIELD SHAPED AND PAINTED TO
MATCH FABRICATED TEGULAR EDGE. THE CUT EDGE OF ALL PANELS SHALL BE
POSITIONED OUT OF VIEW.
3 MOUNT ALL FIXTURES AND DEVICES IN THE CENTER OF ACOUSTIC CEILING PANEL
UNLESS OTHERWISE NOTED.
4 REFER TO MECHANICAL, ELECTRICAL, FIRE ALARM AND FIRE PROTECTION DRAWINGS
FOR FIXTURES NOT SHOWN ON THIS SHEET. COORDINATE LOCATIONS OF FIXTURES
NOT SHOWN WITH LAYOUT INDICATED ON THIS SHEET.
5 PROVIDE ACCESS PANELS IN ALL NON-ACCESSIBLE CEILINGS WHERE SERVICE OR
ADJUSTMENT TO MECHANICAL, PLUMBING OR ELECTRICAL ITEMS MAY BE REQUIRED.
ACCESS PANELS SHALL BE EQUAL TO THE RATING OF THE WALL OR CEILING IN WHICH
THEY OCCUR. PROVIDE COORDINATED SHOP DRAWING OF ALL REQUIRED ACCESS
PANELS FOR REVIEW.
6 PROVIDE COORDINATION DRAWINGS OF ALL EXPOSED MECHANICAL, ELECTRICAL,
PLUMBING, FIRE PROTECTION, AND AUDIO/VIDEO SYSTEMS FOR REVIEW.
7 ALL GYPSUM BOARD CEILINGS TO BE PAINTED P18 UNLESS OTHERWISE NOTED.
8 PAINT CEILING ACCESS PANELS AND MECHANICAL GRILLES / DIFFUSERS WHERE THEY
OCCUR IN GYPSUM BOARD CEILINGS TO MATCH ADJACENT CEILING FINISH.
1 COORDINATE WITH OWNER FOR SPECIALTY BLACKLIGHT PAINT FINISHES TO BE
INSTALLED IN THIS ROOM BY SEPARATE VENDOR.
2 NO CEILING.
3 X-RAY STATIONARY RAIL CROSS-MEMBERS. REFER TO STRUCTURAL FOR FURTHER
INFORMATION.
4 CEILING HEIGHT NOTED FROM ELEVATION ABOVE ROOF LEVEL
REVISION SCHEDULE
NAME DATE
1/4" = 1'-0"D7 PARTIAL REFLECTED CEILING PLAN AT LOBBY/WAITING 101
Received by DiMarco 2/15/2021