Loading...
HomeMy WebLinkAboutA212 First Floor Reflected Ceiling Plan Sector 2SD SD SD SD SD SD SD SD SD SD SD SD SD SD OS OS OS SD SD SD OS M M M F 100C HOLDING/MAIL 100EA ELEV A 121 EXAM 120 EXAM 119 RADIOLOGY (X-RAY) 118 EXAM 111 SOILED WORK112 EXAM113 EXAM 114 EXAM 115 EXAM 116 EXAM 117 TREATMENT 106 TRIAGE/ INTERVIEW 110 STAT LAB/ MED 109 EVS 108 NURSE CORE 105B SUB-WAITING 105C PoS PATIENT TOILET 101 LOBBY/WAITING 101A VISITOR TOILET 100B PUBLIC TOILET 100A PUBLIC TOILET 102 STAFF BREAK 104 SHARED PROVIDER OFFICE 103 STAFF TOILET 100EB ELEV B 100V2 VESTIBULE 105 CIRCULATION WD1 10' -9 1/2" APC2 9' -6" APC2 9' -6"APC2 9' -6" APC2 9' -6" APC2 9' -6" APC2 9' -6"APC2 9' -0" APC2 9' -0" APC1 9' -6" APC1 9' -6" LAP1 10' -6" 9' -4" APC2 9' -6" APC2 9' -6" APC1 9' -6" 10' -0" 9' -6" APC2 9' -0" APC2 9' -0" APC2 9' -6" APC2 9' -0" APC2 9' -0" APC2 9' -6" APC2 9' -6" APC2 9' -6" APC2 9' -6" APC2 9' -6" APC2 9' -6" APC2 9' -6" APC2 9' -6" LAP1 9' -6" APC2 9' -6" 107 CLEAN HOLDING APC2 9' -0" D11 A562 ________________________________________________ A7 A501 ________________________________________________SECTOR 2SECTOR 1S E C T O R 2SECTOR 3 7' -2" 128 BLOOD DRAW (PoS) 7' -2" F10 A561 ________________________________________________ F1 A561 SIM ________________________________________________ 9' -0" 7' -2" F7 A561 ________________________________________________ ALIGN ALIGN ALIGN 8' -0" F7 A561 ________________________________________________ 8' -0" F7 A561 ________________________________________________ 7' -2"F7 A561 ________________________________________________ 7' -2"F7 A561 ________________________________________________ 7' -2" F7 A561 ________________________________________________ 7' -2" F7 A561 ________________________________________________ 7' -2"F7 A561 ________________________________________________ 7' -2" F7 A561 ________________________________________________ 7' -2" F7 A561 ________________________________________________ 7' -2" F7 A561 ________________________________________________ 7' -2"F7 A561 ________________________________________________ H10 A561 ________________________________________________ F1 A561 SIM ________________________________________________ 9' -4" ALIGN A L IG N GYP. BD. 9' -4"ALIGN A L IG N A L IG N F1 A561 SIM ________________________________________________ 7' -2" F7 A561 ________________________________________________ 7' -2" F7 A561 ________________________________________________ 7' -2" D9 A561 ________________________________________________ D9 A561 ________________________________________________ D9 A561 ________________________________________________ 7' -2" F7 A561 ________________________________________________ D9 A561 ________________________________________________ D9 A561 ________________________________________________ D9 A561 ________________________________________________ D9 A561 ________________________________________________ D9 A561 ________________________________________________ D9 A561 ________________________________________________ F10 A561 ________________________________________________ 7' -2" 7' -2" F7 A561 ________________________________________________ 9' -4" F1 A561 SIM ________________________________________________ D11 A561 ________________________________________________ D9 A561 ________________________________________________ D9 A561 ________________________________________________ D9 A561 ________________________________________________ F7 A561 ________________________________________________ D9 A561 ________________________________________________ F7 A561 ________________________________________________ F1 A561 SIM ________________________________________________ 8' -0" F7 A561 ________________________________________________ 7' -2"F7 A561 ________________________________________________ 9' -4" D5 A561 ________________________________________________5 1/2"ALIGN 4 7 /8"ALIGN5 1/2"ALIGNALIGN WITH CORNER 2 ' - 6 "3' - 6"ALIGNALIGN7 1/4"1' - 8"7' - 6"EQ7' - 8"7' - 8"EQEQEQ2' - 1" E Q E Q 4' - 0" 4 ' - 0 "3' - 2" 4 ' - 6 "4 ' - 6 "2 ' - 9 "EQEQEQEQEQ EQ EQEQ EQEQ10"3' - 0"4' - 8"14' - 6"3 P6 P6 SIDES P6 SIDES P5 P5 SIDES P5 P5 SIDES P5 P5 SIDES P5 P5 SIDES P5 P5 SIDES P5P5 SIDES P5 P5 SIDES P5 P5 SIDES P5 P5 SIDES P5 P5 SIDES P5 P5 SIDES P5 P5 SIDES P5 P5 SIDES P5 SIDES P6P6 SIDES P 5 P 5 S ID E S P 5 P 5 S ID E S P 5 P 5 S ID E S P5P5 SIDES P17 SIDES D10 A501 ________________________________________________ A2 A561 ________________________________________________ P6 SIDES P6 9' -4"4 7/ 8 " 7 ' - 0 "APC3 9' -6" H1 A501 ________________________________________________ F2 A455 ________________________________________________ALI GNAL I GNA213 D7 LINEAR PENDANT LIGHT FIXTURE LINEAR SURFACE MOUNTED LIGHT FIXTURE LAY-IN/RECESSED DIRECT/INDIRECT LIGHT FIXTURES RECESSED LIGHT FIXTURE RETURN AIR/ EXHAUST GRILLE SUPPLY AIR GRILLE PROJECTION SCREEN - MANUAL DATA/VIDEO PROJECTOR. CENTER MOUNT ON PROJECTION SCREEN PENDANT LIGHT FIXTURESURFACE MOUNTED LIGHT FIXTURES PROJECTION SCREEN - MOTORIZED SURFACE MOUNTED TRACK LIGHT FIXTURE SPRINKLER HEAD EXIT SIGN SMOKE DETECTOR OCCUPANCY SENSOR RECESSED COVE LIGHT FIXTURE LAY-IN/ RECESSED TROFFER LIGHT FIXTURES LAY-IN/ RECESSED PARABOLIC LIGHT FIXTURES WALL WASHER LIGHT FIXTURE SPEAKER WOOD PANEL CEILING 2' X 4' ACOUSTICAL PANEL CEILING SYSTEM LINEAR METAL CEILING LINEAR RECESSED LIGHT FIXTURE (W) - WALL WASH GYPSUM BOARD CEILINGS AND SOFFITS 2' X 2' ACOUSTICAL PANEL CEILING SYSTEM ACCESS PANEL W LINEAR DIFFUSER GYPSUM BOARD CEILINGS AND SOFFITS DOME SAFETY MIRROR 1'-0"CEILING HEIGHT/ MATERIAL(APC#) FIRE ALARM STROBE CUBICLE CURTAIN PS NOTE: REFER TO FINISH/MATERIAL LEGEND FOR CEILING TYPES KEYED INTO CEILING HEIGHT/MATERIAL TAG. RECESSED WINDOW SHADE LINEAR GRID MOUNTED LIGHT FIXTURES GEOMETRIC ACOUSTICAL PANEL CEILING SYSTEM 2' X 4' CLEANROOM ACOUSTICAL PANEL CEILING SYSTEM WOOD SIDINGACCESSIBLE WOOD CEILING SECTOR 1 SECTOR 2 SECTOR 3 DATE: PROJECT: OTHER: DRAWN BY: A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 11 12 H I 11 12 H I 619 West State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration.2/5/2021 5:16:43 PMA212 FIRST FLOOR REFLECTED CEILING PLAN - SECTOR 2 02/05/2021 2018089 KAS, HRT Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGGENERAL REFLECTED CEILING PLAN NOTES CEILING MATERIALS KEY PLAN LIGHT FIXTURES 0'1'2'4'8' OTHER KEYED REFLECTED CEILING PLAN NOTES # 1/4" = 1'-0"A1 FIRST FLOOR REFLECTED CEILING PLAN - SECTOR 2 1 CENTER ACOUSTIC CEILING PANELS WITHIN FIELD UNLESS OTHERWISE NOTED. PARTIAL PANELS AT ROOM PERIMETER SHALL NOT BE LESS THAN 6". 2 THE EDGE OF ALL CUT TEGULAR PANELS SHALL BE FIELD SHAPED AND PAINTED TO MATCH FABRICATED TEGULAR EDGE. THE CUT EDGE OF ALL PANELS SHALL BE POSITIONED OUT OF VIEW. 3 MOUNT ALL FIXTURES AND DEVICES IN THE CENTER OF ACOUSTIC CEILING PANEL UNLESS OTHERWISE NOTED. 4 REFER TO MECHANICAL, ELECTRICAL, FIRE ALARM AND FIRE PROTECTION DRAWINGS FOR FIXTURES NOT SHOWN ON THIS SHEET. COORDINATE LOCATIONS OF FIXTURES NOT SHOWN WITH LAYOUT INDICATED ON THIS SHEET. 5 PROVIDE ACCESS PANELS IN ALL NON-ACCESSIBLE CEILINGS WHERE SERVICE OR ADJUSTMENT TO MECHANICAL, PLUMBING OR ELECTRICAL ITEMS MAY BE REQUIRED. ACCESS PANELS SHALL BE EQUAL TO THE RATING OF THE WALL OR CEILING IN WHICH THEY OCCUR. PROVIDE COORDINATED SHOP DRAWING OF ALL REQUIRED ACCESS PANELS FOR REVIEW. 6 PROVIDE COORDINATION DRAWINGS OF ALL EXPOSED MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION, AND AUDIO/VIDEO SYSTEMS FOR REVIEW. 7 ALL GYPSUM BOARD CEILINGS TO BE PAINTED P18 UNLESS OTHERWISE NOTED. 8 PAINT CEILING ACCESS PANELS AND MECHANICAL GRILLES / DIFFUSERS WHERE THEY OCCUR IN GYPSUM BOARD CEILINGS TO MATCH ADJACENT CEILING FINISH. 1 COORDINATE WITH OWNER FOR SPECIALTY BLACKLIGHT PAINT FINISHES TO BE INSTALLED IN THIS ROOM BY SEPARATE VENDOR. 2 NO CEILING. 3 X-RAY STATIONARY RAIL CROSS-MEMBERS. REFER TO STRUCTURAL FOR FURTHER INFORMATION. 4 CEILING HEIGHT NOTED FROM ELEVATION ABOVE ROOF LEVEL REVISION SCHEDULE NAME DATE Received by DiMarco 2/15/2021