HomeMy WebLinkAboutA160 Roof PlanFD
E7
A401
________________________________________________
E7
A401
________________________________________________
1 2 3
4
5
A
B
C
A5
A401
________________________________________________
A5
A401
________________________________________________
E
3.8
F
3.9
TAPERED ROOF INSULATION
AS REQUIRED TO PROVIDE
POSITIVE SLOPE OF MIN 1/4"
PER FOOT TO DRAIN
24" x 24" x 1"
SPLASH BLOCK
4" DIAMETER
PREFINISHED
ALUMINUM
DOWNSPOUT
4" DIAMETER
PREFINISHED
ALUMINUM
DOWNSPOUT
24" x 24" x 1"
SPLASH BLOCK
6" BACKUP
ROOF DRAIN
6" ROOF
DRAIN
6" BACKUP
ROOF DRAIN
6" ROOF DRAIN
SLOPED ROOF STRUCTURE
ROOF SYSTEM
TYPE 1 (RS-1)
HVAC EQUIPMENT
HVAC EQUIPMENT 10' - 4
3
/4"
1 3 ' - 6 "1 1 ' - 1 1 7 /8 "1
0' - 0"
MI
NSLOPE PARAPET 1/4"
PER FOOT FOR POSITIVE
DRAINAGE, TYPICAL
+5 1/8"±+5 5/8"±
+1 3/8"±
+3 1/2"
D
+1 1/2"±
+4 3/8"±
+4 3/8"±
+5 1/4"±
+6"±
5.5
5.6
4" BACKUP
ROOF DRAIN
4" ROOF DRAIN
4" BACKUP
ROOF DRAIN
4" ROOF
DRAIN
E.1
RB1
RB2
RB2
RB1
RB1
RB1
A
B
A: SMALL SANDSTONE ROCK
B: DRIFT WOOD
RB2
RB1
C
RB1
C: LARGE SHALE ROCK
RB1
ø 5 ' - 0 "ø 4' - 0"ø 2' - 0"RB2
RB1
RBI
B
B
A
SLOPED ROOF STRUCTURE
SLOPED ROOF STRUCTURE
E7
A502
A11
A502
TYP
TYP
E9
A502
________________________________________________
E9
A502
________________________________________________
A7
A502
________________________________________________
TYP
B11
A502
________________________________________________
B9
A502
________________________________________________
LOW
LOW
F11
A502
________________________________________________
VENT
VENT
VENT
VENT
A7
A502
________________________________________________
TYP
A465
E9
B.3
B.5
HVAC EQUIPMENT
HVAC EQUIPMENT 2' - 0"2' - 0"2' - 0"2' - 0"
ROOF WALKWAY
MEMBRANE
SLOPED ROOF STRUCTURE
A1
A453
________________________________________________
A7
A453
________________________________________________
A7
A454
________________________________________________
A1
A454
________________________________________________
A5
A452
________________________________________________
2' - 8" ±
3' - 0" ±PROPERTY LINEPROPERTY LINEST2-R
CRICKET
PROVIDE 4'-0" TALL X 3'-0" WIDE
ACCESS DOOR IN PARAPET WALL;
COORDINATION FINAL LOCATION
WITH STEEL FRAMING
PROVIDE 2'-0" TALL X 3'-0" WIDE
ACCESS DOOR IN PARAPET WALL;
COORDINATION FINAL LOCATION
WITH STEEL FRAMING
PROVIDE 4'-0" TALL X 3'-0" WIDE
ACCESS DOOR IN PARAPET WALL;
COORDINATION FINAL LOCATION
WITH STEEL FRAMING
VIF
2' - 0" ±VIF2' - 0" ±VIF2' - 0" ±E9
A502
________________________________________________
REFER TO EXTERIOR
FINISH SCHEDULE
SHEET A300 FOR
ROOF BALLAST
REFER TO EXTERIOR
FINISH SCHEDULE
SHEET A300 FOR
ROOF BALLAST
FPA
FPA
FPA
FPA
FPA
FPA
1
'
-
2
1/
2
"
2 ' - 8 1 /2 "2 0 ' - 2 1 /4 "2
' -
0
"
2 ' - 9 1 /4 "14
' - 11 1/4"
1 0 "1
' -
5
1/
2
"
1 1 ' - 6 "2' -
3
"
1 0 "20
' -
5
3/
4
"
PROVIDE TWO (2) FALL-
PROTECTION ANCHORS INSIDE
ROOF HATCH, REFER ALSO TO
STRUCTURAL DRAWINGS
PROVIDE TWO (2) FALL-
PROTECTION ANCHORS INSIDE
ROOF HATCH, REFER ALSO TO
STRUCTURAL DRAWINGS
1
B
PREFINISHED ALUMINUM
GUTTER WITH SLOPED
BOTTOM PITCHED FOR
POSITIVE TO DRAINAGE
HIGH POINT
OF GUTTER
SLOPE TO
DOWNSPOUT
SLOPE TO
DOWNSPOUT
ROOF SYSTEM
TYPE 1 (RS-1)
B.3
B.5
SLOPED ROOF
STRUCTURE
A7
A454
________________________________________________
A1
A454
________________________________________________
D11
A502
________________________________________________
CRICKET
DATE:
PROJECT:
OTHER:
DRAWN BY:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Architecture
Planning
Interior Design
11 12
H
I
11 12
H
I
619 West State Street
Ithaca, New York 14850
132 E. Jefferson Street
Syracuse, New York 13202
p 607 273 7600 www.holt.com
WARNING: It is a violation of New
York State Law for any person,
unless acting under the direction of
a licensed Architect, to alter this
document in any way. If a document
bearing the seal of an Architect is
altered, the altering Architect shall
affix to such document his seal and
the notation "altered by" followed by
his signature, the date of such
alteration, and a specific description
of the alteration.2/10/2021 4:52:32 PMA160
ROOF PLAN
02/05/2021
2018089
CRB/GLM Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING3/16" = 1'-0"A1 ROOF PLAN
0'2'4'8'16'
3/16" = 1'-0"H1 STAIR 2 PENTHOUSE ROOF PLAN
REVISION SCHEDULE
NAME DATE
Received by DiMarco 2/15/2021