Loading...
HomeMy WebLinkAboutA121 Second Floor Plan Sector 1DN UP FECFIRE EXTINGUISH CABINET/BRACKET INT CR INTERCOM, REFER TO ELECTRICAL CARD READER, REFER TO ELECTRICAL FDFLOOR DRAIN FCOFLOOR CLEAN OUT FLOOR RECEPTACLE FR EMGSEMERGENCY GAS SHUTOFF CABINET ELECELECTIC PANEL AUTOMATIC DOOR OPERATOR WAVE PLATE PP1 FACPFIRE ALARM CONTROL PANEL RAPREMOTE ANNOUNCIATOR PANEL E7 A401 ________________________________________________ E7 A401 ________________________________________________ 1 2 A B C A302 E1 A5 A401 ________________________________________________ A5 A401 ________________________________________________ E SECTOR 1EWS-1 EWS-1 1B 3B 3B 3B 3B 1E 3A 4C9 3B 2A 232C ST2-2A 232B 243A 9 10' - 4 7/8"6' - 4 5/8"31' - 2"7' - 0 3/4"17' - 11 1/2"8' - 4 1/4"6' - 0 1/8"10' - 10 3/8"7' - 11 7/8"14' - 11 7/8"243 IT/ELEC A301 E1 A302 A1 234 EDUCATION/ CONFERENCE 235A STORAGE 236 STAFF TOILET 241 RESPITE/ MEDITATION 237 STAFF TOILET 238 OFFICE MANUALLY OPERABLE ROOM DIVIDER 239 RESPITE/ LACTATION240 RESPITE/ LACTATION 242 STAFF BREAK 1E 2A 2A2A 5A 2A 2A 3B 1B 239A 237A 238A 242A 3B2B 2A 241A A8 A451 ________________________________________________ A1 A454 ________________________________________________ D A465 E1 A1 A453 ________________________________________________ A7 A453 ________________________________________________95' - 4"2' - 4" MO 3' - 0"12' - 8" MO 3' - 0"6' - 8" MO 4' - 0"10' - 8" MO 3' - 0"7' - 0" MO 3' - 0" EWS-1 EWS-1 A7 A454 ________________________________________________ 235 MULTIPURPOSE/ ACTIVITY SECTOR 3A353 E11 E9 7 5/8" 8' - 5"8' - 6"5' - 7 1/2"5' - 0"25' - 4 7/8"SECTOR 2SECTOR 1240A 236A ST2-2 STAIR 232 CORRIDOR 2A 2A 2B 4A 1A 1B 2A 2A 1A 4A 4C 4C 4C 3B47' - 5 1/4"5' - 5 1/8"9' - 8 1/2"6' - 9 3/4"1' - 0"7' - 11 7/8"14' - 11 7/8"52' - 10 1/4"6' - 7 7/8"11 3/4"2' - 2 3/4"7' - 8"8' - 1 1/4"5' - 2"9' - 8 1/2"7 5/8" 8' - 5" 1' - 0 5/8" 3' - 10 7/8" 3' - 6 1/2" 5' - 7 1/2" 3' - 6 1/2" 3' - 10 7/8" 1' - 0 5/8"21' - 10 7/8" 235A 234A A353 E4 E6 A353 E9 OPP A353 E11OPP A353 D1 D3 A353 D1 A353 D3 A353G10 2B 2' - 4" MO 4' - 0"7' - 4" MO 6' - 0"15' - 0" MO 5' - 0"8' - 4" MO 5' - 0" 10' - 4 7/8"44' - 7 3/8" 4A 235AA FEC B.3 B.5 REFER TO FIREPROOFING SHEETS FOR PROTECTION OF EXPOSED STRUCTURAL MEMBERS 4A4A 4D 4D W21 W32W33W36W27 W25W26W28W24W25 A10 A565 ________________________________________________ 54' - 6 5/8" ±6"4A 8 1/2"A002 A7 SIM 8 1/2" 4A ALIGN 4A 8 1/2" 1' - 8 3/4" 7 7/8"7 5/8"1' - 5 3/4"55' - 4" A002 A11 SIM 4A 4A A002 A7 SIM 2A 21' - 4 3/4" 4D4A4A4A4A4A4A 4D 4D 4D 5A 4A5A 4D 4C 4D 5A A565 A1 CLEAR 4' - 0"CLEAR4' - 0"CR 4A ALIGN 6' - 0" REFEER ALSO TO ALTERNATE #8. SECTOR 1 SECTOR 2 SECTOR 3 DATE: PROJECT: OTHER: DRAWN BY: A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 11 12 H I 11 12 H I 619 West State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration.2/5/2021 4:44:57 PMA121 SECOND FLOOR PLAN - SECTOR 1 02/05/2021 2018089 SAH, CRB, KAS Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1 CONTRACTOR SHALL PROVIDE FIRE RETARDANT WOOD BLOCKING AT ALL FLOOR, WALL, AND CEILING MOUNTED EQUIPMENT, MILLWORK, AND ACCESSORIES PROVIDED UNDER THIS CONTRACT AND EQUIPMENT TO BE PROVIDED BY THE OWNER. 2 CONTRACTOR SHALL PROVIDE BRACING WHERE REQUIRED TO SUPPORT OR STABILIZE ALL NON-STRUCTURAL FRAMING. 3 PROVIDE ACCESS PANELS IN WALLS AND CEILINGS AS REQUIRED TO OBTAIN CONVENIENT MAINTENANCE ACCESS TO ALL VALVES, DAMPERS, CONCEALED JUNCTION BOXES, AND OTHER EQUIPMENT REQUIRING ADJUSTMENT, SERVICE, OR MAINTENANCE. PROVIDE PROPOSED LOCATION AND SIZE OF ALL ACCESS PANELS FOR REVIEW AND APPROVAL BY ARCHITECT PRIOR TO INSTALLATION. 4 PROVIDE EXPANSION JOINT COVERS/ASSEMBLIES AT ALL INTERIOR AND EXTERIOR EXPANSION JOINTS. 5 PROVIDE FIRE RATED ACCESSORIES AT ALL FIRE RATED PARTITIONS. 6 REFER TO CODE CONFORMANCE DRAWING FOR FIRE EXTINGUISHER CABINET LOCATIONS. GENERAL ARCHITECTURAL NOTES CONSTRUCTION LEGEND KEY PLAN KEYED CONSTRUCTION NOTES 1 ADJUST LOCATION OF WINDOW FRAME WITHIN THE MASONRY OPENING TO AVOID STEEL CROSS-BRACING. 2 X-RAY ELEVATING TABLE. 3 X-RAY WALL STAND. 4 X-RAY SYSTEMS CABINET. 5 X-RAY TETHER INTERFACE BOX. 6 X-RAY GRID HOLDER. 7 X-RAY DISCONNECT PANEL. 0'1'2'4'8'1/4" = 1'-0"A2 SECOND FLOOR PLAN - SECTOR 1 # REVISION SCHEDULE NAME DATE Received by DiMarco 2/15/2021