HomeMy WebLinkAboutA121 Second Floor Plan Sector 1DN
UP
FECFIRE EXTINGUISH
CABINET/BRACKET
INT
CR
INTERCOM, REFER
TO ELECTRICAL
CARD READER, REFER
TO ELECTRICAL
FDFLOOR DRAIN
FCOFLOOR CLEAN OUT
FLOOR
RECEPTACLE
FR
EMGSEMERGENCY GAS
SHUTOFF CABINET
ELECELECTIC PANEL AUTOMATIC DOOR
OPERATOR WAVE
PLATE
PP1
FACPFIRE ALARM
CONTROL PANEL
RAPREMOTE
ANNOUNCIATOR
PANEL
E7
A401
________________________________________________
E7
A401
________________________________________________
1 2
A
B
C
A302 E1
A5
A401
________________________________________________
A5
A401
________________________________________________
E
SECTOR 1EWS-1
EWS-1 1B
3B
3B
3B
3B
1E
3A
4C9
3B
2A
232C
ST2-2A
232B
243A
9
10' - 4 7/8"6' - 4 5/8"31' - 2"7' - 0 3/4"17' - 11 1/2"8' - 4 1/4"6' - 0 1/8"10' - 10 3/8"7' - 11 7/8"14' - 11 7/8"243
IT/ELEC
A301
E1
A302
A1
234
EDUCATION/
CONFERENCE
235A
STORAGE
236
STAFF TOILET
241
RESPITE/
MEDITATION
237
STAFF TOILET
238
OFFICE
MANUALLY OPERABLE ROOM
DIVIDER
239
RESPITE/
LACTATION240
RESPITE/
LACTATION
242
STAFF BREAK
1E
2A
2A2A 5A
2A
2A
3B
1B
239A
237A
238A
242A
3B2B
2A
241A
A8
A451
________________________________________________
A1
A454
________________________________________________
D
A465
E1
A1
A453
________________________________________________
A7
A453
________________________________________________95' - 4"2' - 4"
MO
3' - 0"12' - 8"
MO
3' - 0"6' - 8"
MO
4' - 0"10' - 8"
MO
3' - 0"7' - 0"
MO
3' - 0"
EWS-1
EWS-1
A7
A454
________________________________________________
235
MULTIPURPOSE/
ACTIVITY SECTOR 3A353
E11
E9
7 5/8" 8' - 5"8' - 6"5' - 7 1/2"5' - 0"25' - 4 7/8"SECTOR 2SECTOR 1240A
236A
ST2-2
STAIR
232
CORRIDOR
2A
2A
2B
4A 1A
1B
2A
2A
1A 4A
4C
4C 4C
3B47' - 5 1/4"5' - 5 1/8"9' - 8 1/2"6' - 9 3/4"1' - 0"7' - 11 7/8"14' - 11 7/8"52' - 10 1/4"6' - 7 7/8"11 3/4"2' - 2 3/4"7' - 8"8' - 1 1/4"5' - 2"9' - 8 1/2"7 5/8" 8' - 5" 1' - 0 5/8" 3' - 10 7/8" 3' - 6 1/2" 5' - 7 1/2" 3' - 6 1/2" 3' - 10 7/8" 1' - 0 5/8"21' - 10 7/8"
235A
234A
A353 E4
E6
A353
E9 OPP
A353
E11OPP
A353
D1
D3
A353
D1
A353
D3
A353G10
2B
2' - 4"
MO
4' - 0"7' - 4"
MO
6' - 0"15' - 0"
MO
5' - 0"8' - 4"
MO
5' - 0"
10' - 4 7/8"44' - 7 3/8"
4A
235AA
FEC
B.3
B.5
REFER TO FIREPROOFING SHEETS FOR PROTECTION OF
EXPOSED STRUCTURAL MEMBERS
4A4A
4D
4D
W21
W32W33W36W27
W25W26W28W24W25
A10
A565
________________________________________________
54' - 6 5/8" ±6"4A
8 1/2"A002
A7
SIM
8 1/2"
4A
ALIGN
4A
8 1/2"
1' - 8 3/4" 7 7/8"7 5/8"1' - 5 3/4"55' - 4"
A002
A11
SIM
4A
4A
A002
A7
SIM
2A
21' - 4 3/4"
4D4A4A4A4A4A4A
4D 4D 4D
5A
4A5A
4D
4C
4D
5A
A565
A1
CLEAR
4' - 0"CLEAR4' - 0"CR
4A
ALIGN
6' - 0"
REFEER ALSO TO
ALTERNATE #8.
SECTOR 1 SECTOR 2
SECTOR 3 DATE:
PROJECT:
OTHER:
DRAWN BY:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Architecture
Planning
Interior Design
11 12
H
I
11 12
H
I
619 West State Street
Ithaca, New York 14850
132 E. Jefferson Street
Syracuse, New York 13202
p 607 273 7600 www.holt.com
WARNING: It is a violation of New
York State Law for any person,
unless acting under the direction of
a licensed Architect, to alter this
document in any way. If a document
bearing the seal of an Architect is
altered, the altering Architect shall
affix to such document his seal and
the notation "altered by" followed by
his signature, the date of such
alteration, and a specific description
of the alteration.2/5/2021 4:44:57 PMA121
SECOND
FLOOR PLAN -
SECTOR 1
02/05/2021
2018089
SAH, CRB, KAS Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1 CONTRACTOR SHALL PROVIDE FIRE RETARDANT WOOD BLOCKING AT ALL FLOOR,
WALL, AND CEILING MOUNTED EQUIPMENT, MILLWORK, AND ACCESSORIES PROVIDED
UNDER THIS CONTRACT AND EQUIPMENT TO BE PROVIDED BY THE OWNER.
2 CONTRACTOR SHALL PROVIDE BRACING WHERE REQUIRED TO SUPPORT OR STABILIZE
ALL NON-STRUCTURAL FRAMING.
3 PROVIDE ACCESS PANELS IN WALLS AND CEILINGS AS REQUIRED TO OBTAIN
CONVENIENT MAINTENANCE ACCESS TO ALL VALVES, DAMPERS, CONCEALED
JUNCTION BOXES, AND OTHER EQUIPMENT REQUIRING ADJUSTMENT, SERVICE, OR
MAINTENANCE. PROVIDE PROPOSED LOCATION AND SIZE OF ALL ACCESS PANELS FOR
REVIEW AND APPROVAL BY ARCHITECT PRIOR TO INSTALLATION.
4 PROVIDE EXPANSION JOINT COVERS/ASSEMBLIES AT ALL INTERIOR AND EXTERIOR
EXPANSION JOINTS.
5 PROVIDE FIRE RATED ACCESSORIES AT ALL FIRE RATED PARTITIONS.
6 REFER TO CODE CONFORMANCE DRAWING FOR FIRE EXTINGUISHER CABINET
LOCATIONS.
GENERAL ARCHITECTURAL NOTES
CONSTRUCTION LEGEND
KEY PLAN
KEYED CONSTRUCTION NOTES
1 ADJUST LOCATION OF WINDOW FRAME WITHIN THE MASONRY OPENING TO AVOID
STEEL CROSS-BRACING.
2 X-RAY ELEVATING TABLE.
3 X-RAY WALL STAND.
4 X-RAY SYSTEMS CABINET.
5 X-RAY TETHER INTERFACE BOX.
6 X-RAY GRID HOLDER.
7 X-RAY DISCONNECT PANEL.
0'1'2'4'8'1/4" = 1'-0"A2 SECOND FLOOR PLAN - SECTOR 1
#
REVISION SCHEDULE
NAME DATE
Received by DiMarco 2/15/2021