Loading...
HomeMy WebLinkAboutA113 First Floor Plan Sector 3RAPUP A303 C5 3 4 E 3.8 F 3.9 EWS-1 100V1 VESTIBULE 100V2 VESTIBULE 3A A5 A455 ________________________________________________ A9 A455 ________________________________________________ 124A A301A3 125 EVS D A462 A1 A353 G4 G9 A501 G8 1 4 7 °SECTOR 3SECTOR 1S E C T O R 2SECTOR 3 125A 124 REGISTRATION 123 WAITING / CIRCULATION ST1-1 STAIR 1 2A 2B 1A 1A 12 A351 E11 13' - 0 1/4"5' - 6 1/2" 6 ' - 1 3 /4 " 2 2 ' - 4 1 /8 "ST1-1A A353 G11 2 ' - 4 "40 ' - 0 "PP1P P 1 P P 1 P P 1 CR100V1A A360 F9 F6 A360 F1 M O2' - 0 "1 1 ' - 0 "M O5' - 0 "8 ' - 0 "M O3' - 0 "5 ' - 0 "A562 G1 P P 1 6' - 2" A002 B5 A002 B7 E.1 1A1A 101 A353 H11 1 6 ' - 8 "A563 G1 1 05' -6" A353 H4 ESF-1 ESF-1 ESF-1 ESF-1 A002 B5 1 ' - 6 "A002 A7 SIM 6 3 /4" 9 7 /8 "5D 5D W33 W25 A353 H10 A353 H8 A353 H6 OPEN TO ABOVE 100V1B 100V2A ESF3 ESF110' - 1" MI NUMUM CLEARESF6 2A1' - 6" 96° 123A ESF3 ESF-1 ESF-1 2A A10 A501 ________________________________________________ P P 1 4D 4C 4D 2B ISF1 ISF3 PP1PP1 3' - 11 3/4"17' - 4 3/8"1' - 10" 6' - 8 1/4"7' - 6 1/8"5' - 10 1/8" 100 MAIN LOBBY A2 A455 ________________________________________________15 ' - 2 3/ 4 " SECTOR 1 SECTOR 2 SECTOR 3 FECFIRE EXTINGUISH CABINET/BRACKET INT CR INTERCOM, REFER TO ELECTRICAL CARD READER, REFER TO ELECTRICAL FDFLOOR DRAIN FCOFLOOR CLEAN OUT FLOOR RECEPTACLE FR EMGSEMERGENCY GAS SHUTOFF CABINET ELECELECTIC PANEL AUTOMATIC DOOR OPERATOR WAVE PLATE PP1 FACPFIRE ALARM CONTROL PANEL RAPREMOTE ANNOUNCIATOR PANEL DATE: PROJECT: OTHER: DRAWN BY: A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 11 12 H I 11 12 H I 619 West State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration.2/5/2021 4:44:50 PMA113 FIRST FLOOR PLAN - SECTOR 3 02/05/2021 2018089 SAH, CRB, KAS Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDINGGENERAL ARCHITECTURAL NOTES CONSTRUCTION LEGEND KEY PLAN KEYED CONSTRUCTION NOTES 0'1'2'4'8' 1/4" = 1'-0"B3 FIRST FLOOR PLAN - SECTOR 3 1 CONTRACTOR SHALL PROVIDE FIRE RETARDANT WOOD BLOCKING AT ALL FLOOR, WALL, AND CEILING MOUNTED EQUIPMENT, MILLWORK, AND ACCESSORIES PROVIDED UNDER THIS CONTRACT AND EQUIPMENT TO BE PROVIDED BY THE OWNER. 2 CONTRACTOR SHALL PROVIDE BRACING WHERE REQUIRED TO SUPPORT OR STABILIZE ALL NON-STRUCTURAL FRAMING. 3 PROVIDE ACCESS PANELS IN WALLS AND CEILINGS AS REQUIRED TO OBTAIN CONVENIENT MAINTENANCE ACCESS TO ALL VALVES, DAMPERS, CONCEALED JUNCTION BOXES, AND OTHER EQUIPMENT REQUIRING ADJUSTMENT, SERVICE, OR MAINTENANCE. PROVIDE PROPOSED LOCATION AND SIZE OF ALL ACCESS PANELS FOR REVIEW AND APPROVAL BY ARCHITECT PRIOR TO INSTALLATION. 4 PROVIDE EXPANSION JOINT COVERS/ASSEMBLIES AT ALL INTERIOR AND EXTERIOR EXPANSION JOINTS. 5 PROVIDE FIRE RATED ACCESSORIES AT ALL FIRE RATED PARTITIONS. 6 REFER TO CODE CONFORMANCE DRAWING FOR FIRE EXTINGUISHER CABINET LOCATIONS. 1 ADJUST LOCATION OF WINDOW FRAME WITHIN THE MASONRY OPENING TO AVOID STEEL CROSS-BRACING. 2 X-RAY ELEVATING TABLE. 3 X-RAY WALL STAND. 4 X-RAY SYSTEMS CABINET. 5 X-RAY TETHER INTERFACE BOX. 6 X-RAY GRID HOLDER. 7 X-RAY DISCONNECT PANEL. # REVISION SCHEDULE NAME DATE Received by DiMarco 2/15/2021