Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A111 First Floor Plan Sector 1
UP FD FECFIRE EXTINGUISH CABINET/BRACKET INT CR INTERCOM, REFER TO ELECTRICAL CARD READER, REFER TO ELECTRICAL FDFLOOR DRAIN FCOFLOOR CLEAN OUT FLOOR RECEPTACLE FR EMGSEMERGENCY GAS SHUTOFF CABINET ELECELECTIC PANEL AUTOMATIC DOOR OPERATOR WAVE PLATE PP1 FACPFIRE ALARM CONTROL PANEL RAPREMOTE ANNOUNCIATOR PANEL E7 A401 ________________________________________________ E7 A401 ________________________________________________ 1 2 A B C A302 E1 A5 A401 ________________________________________________ A5 A401 ________________________________________________ EQ EQ 9' - 8 3/8"9' - 5 1/2"7' - 1 7/8"1' - 4 5/8"2' - 4 1/4"19' - 7 7/8"3' - 3 1/2"6' - 6 3/4"18' - 8 7/8"14' - 5"7 3/4"9 9 ST2-1 STAIR 2 137 CLEAN LINEN HOLDING 145 MECHANICAL 140 MAIN SERVER 141 EMERGENCY EQUIPMENT ROOM 142 MAIN ELECTRICAL 138 SUPPLY CHAIN AREA 143 CORRIDOR 139 EVS SUPPLY & EQUIPMENT 138A BUILDING MAINTENANCE TOILET/SHOWER 146 WATER SERVICE 130 BLOOD DRAW 129 BLOOD DRAW 128 BLOOD DRAW (PoS) 126 LABORATORY133 STAFF BREAK 134 CLEAN SUPPLY 131 STAFF TOILET 127 SPECIMEN TOILET 132 SOILED EWS-1 EWS-1 EWS-1 136A 135B 137A 135A 138A 122B 139A 130A 129A 123B 131A 133A ST2-1A ST2-1B 142A 141A 145A146A 140A 105B 138B 139B 143A 128A 126A 122 CORRIDOR EWS-1 EWS-1 3B 3B 3B 2B 1A 1A 3B 3B 3B 1A 3B 1A 1A 1A 3A 3A 3A 1A 1A 1A 1A 1A 1A 1A 1A 1A 1A 3A 3B A465 A1 135 CORRIDOR 143B 138AA 8 3/4" 11' - 2 3/8"7' - 3 3/8"2' - 9"6' - 11 7/8"9' - 8 7/8"10' - 11 5/8" 7 1/2"9' - 6 1/4"11' - 0 1/4"8' - 6"13' - 9 3/8"6' - 8 1/2"CLEAR6' - 0" MINCLEAR6' - 0" MIN9' - 8 3/8"2' - 9"6' - 8 1/2"8' - 6 1/2"2' - 4 7/8"12' - 10 3/4"10' - 0 1/2"6' - 6 1/4"11' - 6 3/4"6' - 4 7/8"6' - 4 7/8"5' - 11 7/8"2' - 10 1/2"6 5/8"124A A301 E1 A302 A1 A8 A451 ________________________________________________ A1 A454 ________________________________________________ A353A9 A353 G2 D A11 A353 A8 A5 A351 C9 A351 A7 A4 A1 A351 C1 C3 A351 C7 C5 A1 A453 ________________________________________________ A7 A453 ________________________________________________ 144 STORAGE 144A 54' - 6 5/8" ± 13' - 4" MO 6' - 4"3' - 4" MO 5' - 0"19' - 0" MO 3' - 0"95' - 4"14' - 0"MO4' - 4"29' - 8"MO4' - 4"3' - 0"MO4' - 0"36' - 0"EWS-1 A7 A454 ________________________________________________SECTOR 2SECTOR 1SECTOR 3SECTOR 11E 3B 132A 136 WASTE HOLDING 3B 134A 1A 1A 127A 1A 3B 1A 1A 1A 3B 1A 1A 1A 5B 3B 124 REGISTRATION 123 WAITING / CIRCULATION C11 2' - 0"2' - 0"7 1/2" 4' - 7 1/2"6' - 0"5' - 3"17' - 0"6' - 4"10' - 3 7/8"12' - 7 3/4"6' - 6 1/8"30' - 2 7/8"3' - 7 3/4"6' - 6 1/4"10 1/2"10' - 5 7/8"6' - 7 1/4"2' - 10 7/8"5' - 1"7' - 10"8"11' - 3 1/8"7' - 3 3/8"9' - 11 5/8"4' - 6 7/8"6' - 10 7/8"9' - 0"CLEAR2' - 6"B.3 B.5 A353 G2 SIM A353 G2OPP 1A 1A 1A ROOF LEADER DOWNSPOUT 4A 4A 4A W25W32 8' - 11"7' - 4 3/4"17' - 0 1/2"6' - 8 1/2"6"6"4A4A PASS-THRU SPECIMEN CABINET W25 RECESSED WATER DISPENSER FEC FECFEC 4A BL-F 1B FD 1' - 4" 117 TREATMENT 52' - 0" 6" 6" EWS-1 A002 A5 A002 A7 SIM A002 A7 A002 A11 A002 A710 7/8"4A CLEAR 2' - 1" 3B 3A ALIGN 9 4A 1A 4D 4D 2B 4D 4D 5B 4D4D 4A FEC CR PP1 PP1PP1PP1 PP1 CRPP1CR 1 FD FECSECTOR 1 SECTOR 2 SECTOR 3 DATE: PROJECT: OTHER: DRAWN BY: A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 11 12 H I 11 12 H I 619 West State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration.2/5/2021 4:44:35 PMA111 FIRST FLOOR PLAN - SECTOR 1 02/05/2021 2018089 SAH, CRB, KAS Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1 CONTRACTOR SHALL PROVIDE FIRE RETARDANT WOOD BLOCKING AT ALL FLOOR, WALL, AND CEILING MOUNTED EQUIPMENT, MILLWORK, AND ACCESSORIES PROVIDED UNDER THIS CONTRACT AND EQUIPMENT TO BE PROVIDED BY THE OWNER. 2 CONTRACTOR SHALL PROVIDE BRACING WHERE REQUIRED TO SUPPORT OR STABILIZE ALL NON-STRUCTURAL FRAMING. 3 PROVIDE ACCESS PANELS IN WALLS AND CEILINGS AS REQUIRED TO OBTAIN CONVENIENT MAINTENANCE ACCESS TO ALL VALVES, DAMPERS, CONCEALED JUNCTION BOXES, AND OTHER EQUIPMENT REQUIRING ADJUSTMENT, SERVICE, OR MAINTENANCE. PROVIDE PROPOSED LOCATION AND SIZE OF ALL ACCESS PANELS FOR REVIEW AND APPROVAL BY ARCHITECT PRIOR TO INSTALLATION. 4 PROVIDE EXPANSION JOINT COVERS/ASSEMBLIES AT ALL INTERIOR AND EXTERIOR EXPANSION JOINTS. 5 PROVIDE FIRE RATED ACCESSORIES AT ALL FIRE RATED PARTITIONS. 6 REFER TO CODE CONFORMANCE DRAWING FOR FIRE EXTINGUISHER CABINET LOCATIONS. GENERAL ARCHITECTURAL NOTES CONSTRUCTION LEGEND KEY PLAN KEYED CONSTRUCTION NOTES 1 ADJUST LOCATION OF WINDOW FRAME WITHIN THE MASONRY OPENING TO AVOID STEEL CROSS-BRACING. 2 X-RAY ELEVATING TABLE. 3 X-RAY WALL STAND. 4 X-RAY SYSTEMS CABINET. 5 X-RAY TETHER INTERFACE BOX. 6 X-RAY GRID HOLDER. 7 X-RAY DISCONNECT PANEL. 0'1'2'4'8'1/4" = 1'-0"A2 FIRST FLOOR PLAN - SECTOR 1 # REVISION SCHEDULE NAME DATE Received by DiMarco 2/15/2021