Loading...
HomeMy WebLinkAboutA002 Interior Wall & Fireproofing Systems2_ 2A 2B 2C 2D 5_ 5A 5B 5C 5D 1_ 1A 1B 1C 1D 1E 3_ 3A 3B 3C 3D 4_ 4A 4B 4C 4D 7_ 7A 7B 7C 7D 7E 9 FS-1RS-1RS-2EWS-1EWS-1EWS-1 EWS-1EWS-18 6_ 6A 6B 6C 6D 6E 10 1211 EWS-1FS-1EWS-3 EWS-3 CEILING PLANE, SEE REFLECTED CEILING PLANS (2) 5/8"VARIES (2) 5/8" 6 1/8" • EXTEND TO UNDERSIDE OF DECK • RATED AS REQUIRED BY CODE CONFORMANCE PLANS, REFER TO UL DESIGN U419 • ACOUSTICAL PERFORMANCE - STC 50 • PROVIDE TILE BACKER PANEL, IN LIEU OF GYPSUM BOARD AT LOCATIONS TO BE TILED SEALANT, BOTH SIDES, ENTIRE PERIMETER UNDERSIDE OF DECK GYPSUM BOARD SOUND ATTENUATION BLANKET METAL STUDS @ 16" OC GYPSUM BOARD WALL BASE, SEE FINISH SCHEDULE SEALANT, BOTH SIDES, ENTIRE PERIMETER 3-5/8" STUD 6" STUD 2 1/2" STUD 1 5/8" STUD CEILING PLANE, SEE REFLECTED CEILING PLANS 4 7/8" VARIES (2) 5/8"SEALANT, ENTIRE PERIMETER UNDERSIDE OF DECK METAL STUDS @ 16" OC GYPSUM BOARD WALL BASE, SEE FINISH SCHEDULE • EXTEND TO UNDERSIDE OF DECK • PROVIDE TILE BACKER PANEL, IN LIEU OF GYPSUM BOARD AT LOCATIONS TO BE TILED SEALANT, ENTIRE PERIMETER 3-5/8" STUD 6" STUD 2 1/2" STUD 1 5/8" STUD • EXTEND TO UNDERSIDE OF DECK • RATED AS REQUIRED BY CODE CONFORMANCE PLANS, REFER TO UL DESIGN U419 • ACOUSTICAL PERFORMANCE - STC 40 • PROVIDE TILE BACKER PANEL, IN LIEU OF GYPSUM BOARD AT LOCATIONS TO BE TILED 5/8"VARIES 5/8" 4 7/8" CEILING PLANE, SEE REFLECTED CEILING PLANS SEALANT, BOTH SIDES, ENTIRE PERIMETER UNDERSIDE OF DECK GYPSUM BOARD SOUND ATTENUATION BLANKET GYPSUM BOARD SEALANT, BOTH SIDES, ENTIRE PERIMETER METAL STUDS @ 16" OC WALL BASE, SEE FINISH SCHEDULE 3-5/8" STUD 6" STUD 2 1/2" STUD 1 5/8" STUD 8" STUD CEILING PLANE, SEE REFLECTED CEILING PLANS 5/8"VARIES (2) 5/8" 5 1/2" • EXTEND TO UNDERSIDE OF DECK • RATED AS REQUIRED BY CODE CONFORMANCE PLANS, REFER TO UL DESIGN U419 • ACOUSTICAL PERFORMANCE -STC 45 • PROVIDE TILE BACKER PANEL, IN LIEU OF GYPSUM BOARD AT LOCATIONS TO BE TILED SEALANT, BOTH SIDES, ENTIRE PERIMETER UNDERSIDE OF DECK GYPSUM BOARD SOUND ATTENUATION BLANKET METAL STUDS @ 16" OC GYPSUM BOARD WALL BASE, SEE FINISH SCHEDULE SEALANT, BOTH SIDES, ENTIRE PERIMETER 3-5/8" STUD 6" STUD 2 1/2" STUD 1 5/8" STUD 5/8" CEILING PLANE, SEE REFLECTED CEILING PLANS VARIES 4 1/4" SEALANT, ENTIRE PERIMETER UNDERSIDE OF DECK METAL STUDS @ 16" OC GYPSUM BOARD WALL BASE, SEE FINISH SCHEDULE SEALANT, ENTIRE PERIMETER • EXTEND TO UNDERSIDE OF DECK • PROVIDE TILE BACKER PANEL, IN LIEU OF GYPSUM BOARD AT LOCATIONS TO BE TILED 3-5/8" STUD 6" STUD 2 1/2" STUD 1 5/8" STUD CEILING PLANE, SEE REFLECTED CEILING PLANS • EXTEND TO UNDERSIDE OF DECK • RATED AS REQUIRED BY CODE CONFORMANCE PLANS, REFER TO UL DESIGN U906 • ACOUSTICAL PERFORMANCE - STC 46 (HOLLOW CORE) 7 5/8"WITH STRUCTURAL1" TYPICALCOORDINATECOMPRESSIBLE FILLER UNDERSIDE OF DECK WALL BASE, SEE FINISH SCHEDULE VARIES 5/8" METAL FURRING GYPSUM BOARD 3-5/8" STUD 6" STUD 2 1/2" STUD 1 5/8" STUD 7/8" FURRING CEILING PLANE, SEE REFLECTED CEILING PLANS 3 3/4" 2 1/2"(2) 5/8" 1" SEALANT, ENTIRE PERIMETER UNDERSIDE OF DECK GYPSUM LINER METAL CH STUD GYPSUM BOARD WALL BASE, SEE FINISH SCHEDULE SEALANT, ENTIRE PERIMETER • EXTEND TO UNDERSIDE OF DECK • RATED AS REQUIRED BY CODE CONFORMANCE PLANS, REFER TO UL DESIGN U415, REFER TO NER-258 FOR HORIZONTAL APPLICATIONS • ACOUSTICAL PERFORMANCE - STC 52 • PROVIDE TILE BACKER PANEL, IN LIEU OF GYPSUM BOARD AT LOCATIONS TO BE TILED REFER TO FINISH PLANS FOR FLOOR FINISH CONCRETE SLAB METAL DECK6 1/4"• REFER TO STRUCTURAL DRAWINGS FOR FLOOR SYSTEM • 1-HOUR RATED PER UL DESIGN D902 • 2-HOUR RATED PER UL DESIGN D7992 5/8" MINSPRAY-APPLIED FIREPROOFING STEEL GIRDER/ BEAM/JOIST REFER ALSO TO STRUCTURAL DRAWINGS 2 HOUR FLOOR SYSTEM, SPRAYED FIREPROOFING ON BEAM AND DECK SPRAY-APPLIED FIREPROOFING ROOF SYSTEM • REFER TO STRUCTURAL DRAWINGS FOR FLOOR SYSTEM • 1-HOUR RATED PER UL DESIGN P819 (1-HOUR SPRAY- APPLIED FIREPROOFING) STEEL BEAM/JOIST (W6x16 MINIMUM)SIMSPRAY-APPLIED FIREPROOFING 5/8" GYPSUM BOARD 8 1/2"8 1/2"1' - 5"7 1/2" 7 1/2" 1' - 3" • 1-HOUR RATED UL DESIGN X829 2 1/2" NON- STRUCTURAL METAL FRAMING 2 1/2" NON- STRUCTURAL METAL FRAMING STEEL COLUMN 8"8" 1 5/8" NON-STRUCTURAL METAL FRAMING • 1-HOUR RATED UL DESIGN X8298 1/2"6"SPRAY-APPLIED FIREPROOFING STEEL COLUMN 2 1/2" NON-STRUCTURAL METAL FRAMING 5/8" GYPSUM BOARD1' - 2 1/2"1 5/8" NON-STRUCTURAL METAL FRAMING 8"8" 1 5/8" NON-STRUCTURAL METAL FRAMING • 1-HOUR RATED UL DESIGN X8298 3/4"6"SPRAY-APPLIED FIREPROOFING STEEL COLUMN 2 1/2" NON-STRUCTURAL METAL FRAMING 5/8" GYPSUM BOARD1' - 2 3/4"1 5/8" NON-STRUCTURAL METAL FRAMING CONTRACTOR OPTION TO USE SPRAY APPLIED FIREPROOFING AS SHOWN OR EXTERIOR FIREPROOFING BOARD. CAFCO OR APPROVED EQUAL. PROVIDE UL ASSEMBLY OR EQUIVALENT ENGINEERING JUDGEMENT CONTRACTOR OPTION TO USE SPRAY APPLIED FIREPROOFING AS SHOWN OR EXTERIOR FIREPROOFING BOARD. CAFCO OR APPROVED EQUAL. PROVIDE UL ASSEMBLY OR EQUIVALENT ENGINEERING JUDGEMENT 6"8" 1 5/8" NON-STRUCTURAL METAL FRAMING8 1/2"6"SPRAY-APPLIED FIREPROOFING STEEL COLUMN 5/8" GYPSUM BOARD 2 1/2" NON-STRUCTURAL METAL FRAMING1' - 2 1/2"1' - 2" • 1-HOUR RATED UL DESIGN X829 8"8" • 1-HOUR RATED UL DESIGN X8278 1/2"6"1 5/8" NON-STRUCTURAL METAL FRAMING SPRAY-APPLIED FIREPROOFING HSS STEEL TUBE COLUMN 2 1/2" NON-STRUCTURAL METAL FRAMING 5/8" GYPSUM BOARD1' - 2 1/2"1' - 4" 1 5/8" NON-STRUCTURAL METAL FRAMING CEILING PLANE, SEE REFLECTED CEILING PLANS SEALANT, ENTIRE PERIMETER UNDERSIDE OF DECK GYPSUM LINER METAL CH STUD WALL BASE, SEE FINISH SCHEDULE • EXTEND TO UNDERSIDE OF DECK • RATED AS REQUIRED BY CODE CONFORMANCE PLANS, REFER TO UL DESIGN U415, REFER TO NER-258 FOR HORIZONTAL APPLICATIONS • ACOUSTICAL PERFORMANCE - STC 37 • PROVIDE TILE BACKER PANEL, IN LIEU OF GYPSUM BOARD AT LOCATIONS TO BE TILED GYPSUM BOARD SEALANT, ENTIRE PERIMETER 1"5/8" 2 1/2" 3 1/8" CEILING PLANE, SEE REFLECTED CEILING PLANS • EXTEND TO UNDERSIDE OF DECK • RATED AS REQUIRED BY CODE CONFORMANCE PLANS, REFER TO UL DESIGN U906 • ACOUSTICAL PERFORMANCE - STC 46 (HOLLOW CORE) 7 5/8"WITH STRUCTURAL1" TYPICALCOORDINATECOMPRESSIBLE FILLER UNDERSIDE OF DECK WALL BASE, SEE FINISH SCHEDULE VARIES 5/8" METAL FURRING GYPSUM BOARD 3-5/8" STUD 6" STUD 2 1/2" STUD 1 5/8" STUD 7/8" FURRING CEILING PLANE, SEE REFLECTED CEILING PLANS • EXTEND TO UNDERSIDE OF SOFFITS AS NOTED PER PLANS • BASIS-OF-DESIGN: PILKINGTON PROFILIT; SURFACE TEXTURES: CLEAR, MACRO, SLIMLINE, STANDARD 2 23/64" ALUMINUM BASE CHANNEL STRUCTURAL GLASS CHANNEL ALUMINUM TOP CHANNEL STEEL-FRAMED FIRE-RATED GLASS AND FRAMING SYSTEM FIRE-RESISTIVE GLAZING (120 MIN) • EXTEND TO UNDERSIDE OF DECK, UON • RATED AS REQUIRED BY CODE CONFORMANCE PLANS • ACOUSTICAL PERFORMANCE - STC 44 • BASIS-OF-DESIGN: 1. CONTACT: MIKE AUGUSTINE | 415.230.6708 maugustine@safti.com 1. FRAMING SYSTEM: SAFTI FIRST GPX ARCHITECTURAL SERIES; FINISH CLEAR ANODIZED 2. GLAZING A. BASE BID: SUPERLITE II-XLB (CLEAR TEMPERED) B. ALTERNATE: SUPERLITE II-XL 120 (CLEAR TEMPERED) SEALANT, BOTH SIDES, ENTIRE PERIMETER ALUMINUM STOREFRONT FRAMING GLAZING • EXTEND TO UNDERSIDE OF SOFFITS, TYPICAL, UNO • BASIS-OF-DESIGN: 1. CONTACT: MJD ASSOCIATES OF CNY MARC DONAHUE AND PHIL DONAHUE | 315.432.8401 mdonahue@mjdcorp.com | pdonahue@mjdcorp.com 1. FRAMING SYSTEM: EFCO SERIES 403X 2" X 4 1/2" ALUMINUM STOREFRONT FRAMING; FINISH CLEAR ANODIZED 2. GLAZING A. 1/4" CLEAR TEMPERED, UON B. 3/8" CLEAR TEMPERED IF ONE DIMENSION IS GREATER THAN 5 FEET C. 1/2" CLEAR TEMPERED, IF ONE DIMENSION IS GREATER THAN 7 FEET OR BOTH DIMENSIONS ARE GREATER THAN 5 FEET 4 1/2"2"2"STEEL COLUMN INTUMESCENT COATING • 1-HOUR RATED UL DESIGN AS INDICATED • STEEL SHALL BE FREE OF DIRT, LOOSE SCALE AND OIL • PRIME WITH COMPATIBLE PRIMER PER MANUFACTURER'S RECOMMENDATION • INTUMESCENT COATING • TOPSEAL COATING • SCHEDULED PAINT COATING UL DESIGN Y615 (EXTERIOR) HSS TUBE STEEL COLUMN UL DESIGN Y616 (INTERIOR) UL DESIGN Y614 (EXTERIOR) STEEL BEAM INTUMESCENT COATING • 1-HOUR RATED UL DESIGN N634 • STEEL SHALL BE FREE OF DIRT, LOOSE SCALE AND OIL • PRIME WITH COMPATIBLE PRIMER PER MANUFACTURER'S RECOMMENDATION • INTUMESCENT COATING • TOPSEAL COATING • SCHEDULED PAINT COATING 1-5/8" STEEL STUDS, TYP STEEL COLUMN, REFER TO STRUCTURAL DRAWINGS 5/8" FIRE-RATED GYPSUM BOARD, TYP UL DESIGN X528 1 HR RATING SEE UL FIRE RESISTANCE DIRECTORY VOLUME 1 FOR SPECIFIC CONSTRUCTION INFORMATION NO. 28 MSG GALVANIZED STEEL CORNER BEAD STEEL COLUMN PREFINISHED ALUMINUM COLUMN COVER SPRAY-APPLIED FIREPROOFING • 1-HOUR RATED UL DESIGN X764 • BASIS-OF-DESIGN EXTERIOR FIREPROOFING SYSTEM: ISOLATEK CAFCO FENDOLITE M-II A. BASIS-OF-DESIGN COLUMN COVER SYSTEM: SEE EXTERIOR FINISH SCHEDULE STEEL BASE PLATE BELOW 9" RADIUSSTEEL TUBE PREFINISHED ALUMINUM COLUMN COVER SPRAY-APPLIED FIREPROOFING • 1-HOUR RATED UL DESIGN X768 • BASIS-OF-DESIGN EXTERIOR FIREPROOFING SYSTEM: ISOLATEK CAFCO FENDOLITE M-II • BASIS-OF-DESIGN COLUMN COVER SYSTEM: PAC-CLAD PAC-1000F FLUSH JOINT COLUMN COVER 1. MATERIAL: .125" ALUMINUM 2. FINISH: KYNAR 500 A. COLOR: MANUFACTURER'S PREMIUM COLORS; TBD STEEL BASE PLATE BELOW 9" RADIUS • 1-HOUR RATED UL DESIGN Y616 • STEEL SHALL BE FREE OF DIRT, LOOSE SCALE AND OIL • PRIME WITH COMPATIBLE PRIMER PER MANUFACTURER'S RECOMMENDATION • INTUMESCENT COATING • TOPSEAL COATING • SCHEDULED PAINT COATING6"INTUMESCENT COATING HSS STEEL TUBE COLUMN CONTINUOUS FIRE- RATED SEALANT, BOTH SIDES OF COLUMN MINERAL-WOOL BLANKET INSULATION MINERAL-WOOL BOARD INSULATION IMPALING PINS @ 12" OC STEEL BACKPAN, 22 GA FIRESTOP SEALANT FIRESAFING INSULATION MIN 3" UL DESIGN CW-D-1044 OR APPROVED EQUAL 2 1/2" @ SIM 3 1/2" 1-5/8" STEEL STUDS, TYP 5/8" FIRE-RATED GYPSUM BOARD, TYP UL DESIGN N873 1 HR RATING SEE UL FIRE RESISTANCE DIRECTORY VOLUME 1 FOR SPECIFIC CONSTRUCTION INFORMATION STEEL BEAM, REFER TO STRUCTURAL DRAWINGS NO. 28 MSG GALVANIZED STEEL CORNER BEAD SPRAY-APPLIED FIREPROOFING Z-CLIPS WELDED TO STEEL BEAM 1-5/8" STEEL STUDS, TYP 5/8" FIRE-RATED GYPSUM BOARD, TYP NO. 28 MSG GALVANIZED STEEL CORNER BEAD SPRAY-APPLIED FIREPROOFING STEEL GIRDER/ BEAM/JOIST REFER ALSO TO STRUCTURAL DRAWINGS 1 1/2" = 1'-0"F2 INTERIOR WALL SYSTEM TYPE 2 (IWS-2) 1 1/2" = 1'-0"F7 INTERIOR WALL SYSTEM TYPE 5 (IWS-5) 1 1/2" = 1'-0"F1 INTERIOR WALL SYSTEM TYPE 1 (IWS-1) 1 1/2" = 1'-0"F4 INTERIOR WALL SYSTEM TYPE 3 (IWS-3) 1 1/2" = 1'-0"F5 INTERIOR WALL SYSTEM TYPE 4 (IWS-4) 1 1/2" = 1'-0"F9 INTERIOR WALL SYSTEM TYPE 7 (IWS-7) 1 1/2" = 1'-0"D1 INTERIOR WALL SYSTEM TYPE 9 (IWS-9) 1 1/2" = 1'-0"E7 FLOOR SYSTEM 1 (FS-1) 1 1/2" = 1'-0"D9 TYPICAL ROOF FIREPROOFING 1 1/2" = 1'-0"A1 COLUMN ENCLOSURE DETAIL, TYPICAL 1 1/2" = 1'-0"A7 COLUMN ENCLOSURE DETAIL 1 1/2" = 1'-0"A11 COLUMN ENCLOSURE W10X39 EXTERIOR 1 1/2" = 1'-0"A3 COLUMN ENCLOSURE DETAIL 1 1/2" = 1'-0"F11 INTERIOR WALL SYSTEM TYPE 8 (IWS-8) 1 1/2" = 1'-0"F8 INTERIOR WALL SYSTEM TYPE 6 (IWS-6) 1 1/2" = 1'-0"D2 INTERIOR WALL SYSTEM TYPE 10 (IWS-10) 1 1/2" = 1'-0"D5 INTERIOR WALL SYSTEM TYPE 12 (IWS-12) 1 1/2" = 1'-0"D4 INTERIOR WALL SYSTEM TYPE 11 (IWS-11) 1 1/2" = 1'-0"B1 TYPICAL COLUMN - INTUMESCENT 1 1/2" = 1'-0"B3 TYPICAL BEAM/JOIST/GIRDER - INTUMESCENT 1 1/2" = 1'-0"B9 1 HOUR FIRE-RATED COLUMN WRAP DETAIL DATE: PROJECT: OTHER: DRAWN BY: A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 11 12 H I 11 12 H I 619 West State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration.2/5/2021 4:44:27 PMA002 INTERIOR WALL & FIREPROOFING SYSTEMS 02/05/2021 2018089 CRB/GLM Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1 1/2" = 1'-0"B7 COLUMN - W10 SPRAY FIREPROOFING WITH COLUMN COVER 1 1/2" = 1'-0"B5 COLUMN - HSS6X6 SPRAY FIREPROOFING WITH COLUMN COVER 1 1/2" = 1'-0"A5 COLUMN ENCLOSURE DETAIL 1 1/2" = 1'-0"D11 FLOOR SLAB FIRESTOPPING@CURTAIN WALL REVISION SCHEDULE NAME DATE 1 1/2" = 1'-0"B10 1 HOUR FIRE-RATED HSS BEAM WRAP DETAIL 1 1/2" = 1'-0"B11 1 HOUR FIRE-RATED BEAM WRAP DETAIL Received by DiMarco 2/15/2021