Loading...
HomeMy WebLinkAboutA001 General Notes Exterior Wall & Roof SystemsEWS-1 EWS-2 RS-2EWS-3 ESF-1 RS-1ECW-1 FWS-1 FS-2CS-1CS-2101 ROOM NAME A101 1 1 A101 1 DETAIL ENLARGEMENT WALL SECTION BUILDING SECTION DETAIL SECTION 1 INTERIOR ELEVATION DOOR & INTERIOR WINDOW TAG WALL TAG ROOM IDENTIFICATION EXTERIOR STOREFRONT / CURTAIN WALL & LOUVER TAG EXISTING DOOR DOOR FULL HEIGHT PARTITION PARTIAL HEIGHT PARTITION KEYED NOTE FLOOR ELEVATION 1001 1 REVISION CLOUD & TAG PLAN ELEVATION50'-6" WORKING POINTWP A101 SIM A1 A2 A3 A4 DIMENSION TO THE FACE OF FRAMING AT NEW CONSTRUCTION, TYP. DIMENSION TO THE FACE OF FINISH AT EXISTING CONSTRUCTION DIMENSION TO THE FACE OF FINISH EXISTING PARTITION DD Addendum 1 4/9/2020 1 A101 1 A101 NAME ELEVATION AAP AREA ALARM PANEL ACP ACOUSTICAL CEILING PANEL AFF ABOVE FINISH FLOOR CI CONTINUOUS INSULATION CL CENTERLINE CLL CONTRACT LIMIT LINE CLR CLEAR ETR EXISTING TO REMAIN EJ EXPANSION JOINT FEC FIRE EXTINGUISHER CABINET GA GAUGE HR HOUR MAX MAXIMUM MIN MINIMUM MIR MIRRORED ARCHITECTURAL SYMBOLS NIC NOT IN CONTRACT NPS NOMINAL PIPE SIZE NR NOT REQUIRED OC ON CENTER OD OUTSIDE DIAMETER OFCI OWNER FURNISHED CONTRACTOR INSTALLED OFOI OWNER FURNISHED OWNER INSTALLED VFCC VENDER FURNISHED, CONTRACTOR TO COORDINATE WITH VENDOR AS REQUIRED OPP OPPOSITE RD ROOF DRAIN SF SQUARE FOOT SIM SIMILAR SQ IN SQUARE INCHES TYP TYPICAL UON UNLESS OTHERWISE NOTED ZVB ZONE VALVE BOX ABBREVIATIONS CONTRACT LIMIT LINE MATCHLINE AREA NOT IN CONTRACT (NIC) ALTERNATE WORK SCOPE AS INDICATED # 5/8" GYPSUM BOARD CFMF STUDS 24" OC (18 GAUGE) GLASS-MAT GYPSUM SHEATHING POLYISOCYANURATE BOARD INSULATION MASONRY UNIT, SEE EXTERIOR ELEVATIONS FOR TYPE 1' - 2 7/8" CONTINUOUS VAPOR-IMPERMEABLE AIR BARRIER SYSTEM 6" 1/2" 3 1/2" 1 1/4" 3 5/8" PROVIDED 0.027 REQUIRED 0.047U-FACTOR 2020 ECCCNYS-C402.1.4 OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM REQUIREMENTS - CLIMATE ZONE 6A - METAL FRAMED WALL - OTHER THAN RESIDENTIAL AIR SPACE, WEEPED AND VENTED MASONRY VENEER ANCHOR STRETCH 0.047 3 1/2" MINERAL WOOL BATT INSULATION • RATED AS REQUIRED BY CODE CONFORMANCE PLANS, REFER TO UL DESIGN U425 5/8" 1' - 0 1/2" GYPSUM BOARD CFMF STUDS 24" OC (18 GAUGE) GLASS-MAT GYPSUM SHEATHING CONTINUOUS VAPOR-PERMEABLE AIR BARRIER SYSTEM COMPOSITE POLYISOCYANURATE BOARD INSULATION, FASTEN TO STUD CONTINUOUS FRAME AND CLIP, FASTEN THROUGH COMPOSITE BOARD ONLY COMPOSITE METAL PANEL RAINSCREEN WEATHER BARRIER PROVIDED 0.027 REQUIRED 0.064 U-FACTOR 2020 ECCCNYS-C402.1.4 OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM REQUIREMENTS - CLIMATE ZONE 6A - METAL FRAMED WALL - OTHER THAN RESIDENTIAL 6" 1/2" 4 1/8"1 7/8" 3 1/2"5/8" STRETCH 0.047 3 1/2" MINERAL WOOL BATT INSULATION • RATED AS REQUIRED BY CODE CONFORMANCE PLANS, REFER TO UL DESIGN U425 1/2"COVER BOARD POLYISOCYANURATE BOARD INSULATION VAPOR RETARDER SUBSTRATE BOARD ROOF DECKMIN6"1/2"VARIESTAPERED INSULATION WHERE INDICATED ON ROOF PLAN PROVIDEDREQUIREDU-VALUE 2020 ECCCNYS-C402.1.4 THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS - CLIMATE ZONE 6A - INSULATION ENTIRELY ABOVE ROOF DECK CONTINUOUS .029.032 • REFER TO STRUCTURAL DRAWINGS FOR ROOF FRAMING • 1-HOUR RATED PER UL DESIGN P819 (1-HOUR SPRAY- APPLIED FIREPROOFING) • ROOFING SYSTEM: SEE ROOF PLAN SPRAY-APPLIED FIREPROOFING LAMINATED BASE ROOFING SHEET 2"DECORATIVE ROOFING AGGREGATE / BALLAST COLOR AND DESIGN TBD STRETCH .029 FULLY ADHERED MEMBRANE ROOFING 5/8" GYPSUM BOARD PROVIDED 0.026 REQUIRED 0.064 U-FACTOR 2020 ECCCNYS-C402.1.4 OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM REQUIREMENTS - CLIMATE ZONE 6A - METAL FRAMED WALL - OTHER THAN RESIDENTIAL CFMF STUDS 24" OC (18 GAUGE) • RATED AS REQUIRED BY CODE CONFORMANCE PLANS, UL DESIGN CW-D-1044 OR APPROVED EQUAL • NOTE: MULLION SIZES MAY VARY BY MANUFACTURER, COORDINATE FINAL SIZES AND STEEL REINFORCING REQUIREMENTS WITH MANUFACTURER. 6"3" GLAZED ALUMINUM CURTAIN WALL ASSEMBLY MINERAL-WOOL BOARD INSULATION 1' - 4 1/2" 7 1/2" STRETCH 0.047 MINERAL-WOOL BOARD INSULATION IMPALING PINS @ 12" OC, BOTH SIDE OF BACKPAN ALUMINUM BACKPAN, TYPICAL, UON STEEL BACKPAN, 22 GA AT RATED EXTERIOR WALL LOCATIONS 10" COLUMN CENTERLINE 2" 3" AT RATED EXTERIOR WALL LOCATIONS MINERAL-WOOL BATT INSULATION AT RATED EXTERIOR WALL LOCATIONS • NOTE: MULLION SIZES MAY VARY BY MANUFACTURER, COORDINATE FINAL SIZES AND STEEL REINFORCING REQUIREMENTS WITH MANUFACTURER • TOTAL U-FACTOR: 0.XX (0.34 MAXIMUM) • SHGC: .XX (.40 MAXIMUM) GLAZING ALUMINUM STOREFRONT FRAMING2"2"4 1/2" FULLY ADHERED MEMBRANE ROOFING COVER BOARD POLYISOCYANURATE BOARD INSULATION VAPOR RETARDER SUBSTRATE BOARD ROOF DECK1/2"6"5/8"2020 ECCCNYS-C402.1.4 THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS - CLIMATE ZONE 6A - INSULATION ENTIRELY ABOVE ROOF DECK • REFER TO STRUCTURAL DRAWINGS FOR ROOF FRAMING • 1-HOUR RATED PER UL DESIGN P819 (1-HOUR SPRAY- APPLIED FIREPROOFING) • ROOFING SYSTEM: SEE ROOF PLAN SPRAY-APPLIED FIREPROOFING LAMINATED BASE ROOFING SHEET PROVIDEDREQUIREDU-VALUE CONTINUOUS .029.032 STRETCH .029 GLAZING ALUMINUM CURTAIN WALL FRAMING • NOTE: MULLION SIZES MAY VARY BY MANUFACTURER, COORDINATE FINAL SIZES AND STEEL REINFORCING REQUIREMENTS WITH MANUFACTURER • TOTAL U-FACTOR: 0.XX (0.34 MAXIMUM) • SHGC: 0.XX (.40 MAXIMUM) 7 1/2"2 1/2"2 1/2"2"VARIES CAST-IN-PLACE CONCRETE MODIFIED BITUMINOUS SHEET WATERPROOFING POLYSTYRENE BOARD INSULATIONBELOW GRADE2' - 0" MINPROVIDED 0.095 REQUIRED 0.119U-FACTOR 2020 ECCCNYS-C402.1.4 OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM REQUIREMENTS - CLIMATE ZONE 6A - FOUNDATION WALL UNHEATED SLAB - OTHER THAN RESIDENTIAL STRETCH 1 1/4" 3 5/8" SOLID GROUT 0.092 UNDISTURBED EARTH CONCRETE SLAB REFER TO FINISH PLANS FOR FLOOR FINISH VAPOR RETARDER REFER TO STRUCTURAL DRAWINGS FOR FLOOR SYSTEM STRUCTURAL FILL5"1' - 0"CFMF STUDS 24" OC GLASS-MAT GYPSUM SHEATHING CONTINUOUS VAPOR-PERMEABLE AIR BARRIER SYSTEM COMPOSITE POLYISOCYANURATE BOARD INSULATION, FASTEN TO STUD CONTINUOUS FRAME AND CLIP, FASTEN THROUGH COMPOSITE BOARD ONLY COMPOSITE METAL PANEL RAINSCREEN WEATHER BARRIER MINERAL WOOL BATT INSULATION 2020 ECCCNYS-C402.1.4 THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS - CLIMATE ZONE 6A - FLOORS, JOIST/FRAMING 5/8"3 1/2"1/2"6"PROVIDED 0.027 REQUIRED 0.064 U-FACTOR STRETCH 0.047 CFMF STUDS 24" OC GLASS-MAT GYPSUM SHEATHING CONTINUOUS VAPOR-PERMEABLE AIR BARRIER SYSTEM COMPOSITE POLYISOCYANURATE BOARD INSULATION, FASTEN TO STUD WEATHER BARRIER MINERAL WOOL BATT INSULATION 2020 ECCCNYS-C402.1.4 THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS - CLIMATE ZONE 6A - FLOORS, JOIST/FRAMING 2X FR WOOD FURRING @ 16" OC 1X6 TONGUE & GROOVE WOOD SIDING, PREFINISHED3/4"1 1/2"5/8"3 1/2"1/2"6"PROVIDED 0.027 REQUIRED 0.047U-FACTOR STRETCH 0.047 DATE: PROJECT: OTHER: DRAWN BY: A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 11 12 H I 11 12 H I 619 West State Street Ithaca, New York 14850 132 E. Jefferson Street Syracuse, New York 13202 p 607 273 7600 www.holt.com WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration.2/10/2021 2:34:02 PMA001 GENERAL NOTES, EXTERIOR WALL & ROOF SYSTEMS 02/05/2021 2018089 CRB/GLM Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1 ALL WORK IS NEW UNLESS NOTED AS EXISTING. 2 ANY DISCREPANCY CONTAINED WITHIN ANY OF THE DOCUMENTS SHALL BE UNDERSTOOD TO MEAN THAT THE GREATER QUANTITY AND OR THE BETTER QUALITY SHALL BE PROVIDED IN THE FAVOR OF THE OWNER. 3 REFER TO CODE CONFORMANCE DRAWINGS FOR REQUIRED FIRE RATED CONSTRUCTION. 4 CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN FIELD (EXISTING AND SCHEDULED CONSTRUCTION) AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 5 DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONS. 6 NOTES ON ONE DETAIL OR DRAWING APPLY TO ALL SIMILAR DETAILS AND DRAWINGS. 7 DIMENSIONS NOTED "EQ" ARE EQUAL TO EACH OTHER ONLY IF THEY ARE ON THE SAME DIMENSION STRING AND IN THE SAME ROW. 8 ROOM NUMBERING IS FOR CONSTRUCTION PURPOSES ONLY, ACTUAL ROOM NUMBERING TO BE COORDINATED WITH THE OWNER PRIOR TO ANY SCHEDULING OR LABELING. ALL EQUIPMENT LABELING AND SCHEDULING SHALL BE FORMATTED AS DIRECTED BY OWNER. 9 ANY PORTION OF THE PROJECT WHICH IS DAMAGED AS A RESULT OF CONSTRUCTION ACTIVITY SHALL BE REPAIRED. GENERAL NOTES 1 1/2" = 1'-0"G5 EXTERIOR WALL SYSTEM TYPE 1 (EWS-1) 1 1/2" = 1'-0"G7 EXTERIOR WALL SYSTEM TYPE 2 (EWS-2) 1 1/2" = 1'-0"D6 ROOF SYSTEM TYPE 2 (RS-2) 1 1/2" = 1'-0"G9 EXTERIOR WALL SYSTEM TYPE 3 (EWS-3) 1 1/2" = 1'-0"A4 EXTERIOR STOREFRONT SYSTEM (ESF-1) 1 1/2" = 1'-0"D9 ROOF SYSTEM TYPE 1 (RS-1) 1 1/2" = 1'-0"A5 EXTERIOR CURTAIN WALL SYSTEM (ECW-1) 1 1/2" = 1'-0"A7 FOUNDATION WALL SYSTEM TYPE 1 (FWS-1) 1 1/2" = 1'-0"A9 FLOOR SYSTEM 2 (FS-2) 1 1/2" = 1'-0"D1 EXTERIOR CEILING SYSTEM 1 (CS-1) 1 1/2" = 1'-0"D4 EXTERIOR CEILING SYSTEM 2 (CS-2) REVISION SCHEDULE NAME DATE Received by DiMarco 2/15/2021