HomeMy WebLinkAboutA001 General Notes Exterior Wall & Roof SystemsEWS-1
EWS-2
RS-2EWS-3
ESF-1 RS-1ECW-1
FWS-1 FS-2CS-1CS-2101
ROOM NAME
A101
1
1
A101
1 DETAIL
ENLARGEMENT
WALL SECTION
BUILDING
SECTION
DETAIL SECTION
1
INTERIOR
ELEVATION
DOOR & INTERIOR
WINDOW TAG
WALL TAG
ROOM
IDENTIFICATION
EXTERIOR
STOREFRONT /
CURTAIN WALL
& LOUVER TAG
EXISTING DOOR
DOOR
FULL HEIGHT
PARTITION
PARTIAL HEIGHT
PARTITION
KEYED NOTE
FLOOR ELEVATION
1001
1
REVISION CLOUD
& TAG
PLAN ELEVATION50'-6"
WORKING POINTWP
A101
SIM
A1
A2
A3
A4
DIMENSION TO THE FACE
OF FRAMING AT NEW
CONSTRUCTION, TYP.
DIMENSION TO THE FACE
OF FINISH AT EXISTING
CONSTRUCTION
DIMENSION TO THE FACE
OF FINISH
EXISTING PARTITION
DD Addendum 1
4/9/2020
1
A101
1
A101
NAME
ELEVATION
AAP AREA ALARM PANEL
ACP ACOUSTICAL CEILING PANEL
AFF ABOVE FINISH FLOOR
CI CONTINUOUS INSULATION
CL CENTERLINE
CLL CONTRACT LIMIT LINE
CLR CLEAR
ETR EXISTING TO REMAIN
EJ EXPANSION JOINT
FEC FIRE EXTINGUISHER CABINET
GA GAUGE
HR HOUR
MAX MAXIMUM
MIN MINIMUM
MIR MIRRORED
ARCHITECTURAL SYMBOLS
NIC NOT IN CONTRACT
NPS NOMINAL PIPE SIZE
NR NOT REQUIRED
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFOI OWNER FURNISHED OWNER INSTALLED
VFCC VENDER FURNISHED, CONTRACTOR TO
COORDINATE WITH VENDOR AS REQUIRED
OPP OPPOSITE
RD ROOF DRAIN
SF SQUARE FOOT
SIM SIMILAR
SQ IN SQUARE INCHES
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
ZVB ZONE VALVE BOX
ABBREVIATIONS
CONTRACT LIMIT LINE
MATCHLINE
AREA NOT IN
CONTRACT (NIC)
ALTERNATE WORK
SCOPE AS INDICATED
#
5/8"
GYPSUM BOARD
CFMF STUDS 24" OC (18
GAUGE)
GLASS-MAT GYPSUM
SHEATHING
POLYISOCYANURATE BOARD
INSULATION
MASONRY UNIT, SEE
EXTERIOR ELEVATIONS FOR
TYPE
1' - 2 7/8"
CONTINUOUS
VAPOR-IMPERMEABLE AIR
BARRIER SYSTEM
6"
1/2"
3 1/2"
1 1/4"
3 5/8"
PROVIDED
0.027
REQUIRED
0.047U-FACTOR
2020 ECCCNYS-C402.1.4 OPAQUE THERMAL
ENVELOPE ASSEMBLY MAXIMUM
REQUIREMENTS - CLIMATE ZONE 6A - METAL
FRAMED WALL - OTHER THAN RESIDENTIAL
AIR SPACE, WEEPED AND
VENTED
MASONRY VENEER ANCHOR
STRETCH
0.047
3 1/2"
MINERAL WOOL
BATT INSULATION
• RATED AS REQUIRED BY CODE CONFORMANCE PLANS,
REFER TO UL DESIGN U425
5/8"
1' - 0 1/2"
GYPSUM BOARD
CFMF STUDS 24" OC (18
GAUGE)
GLASS-MAT GYPSUM
SHEATHING
CONTINUOUS
VAPOR-PERMEABLE AIR
BARRIER SYSTEM
COMPOSITE
POLYISOCYANURATE BOARD
INSULATION, FASTEN TO
STUD
CONTINUOUS FRAME AND
CLIP, FASTEN THROUGH
COMPOSITE BOARD ONLY
COMPOSITE METAL PANEL
RAINSCREEN
WEATHER BARRIER
PROVIDED
0.027
REQUIRED
0.064
U-FACTOR
2020 ECCCNYS-C402.1.4 OPAQUE THERMAL
ENVELOPE ASSEMBLY MAXIMUM
REQUIREMENTS - CLIMATE ZONE 6A - METAL
FRAMED WALL - OTHER THAN RESIDENTIAL
6"
1/2"
4 1/8"1 7/8"
3 1/2"5/8"
STRETCH
0.047
3 1/2"
MINERAL WOOL
BATT INSULATION
• RATED AS REQUIRED BY CODE CONFORMANCE PLANS,
REFER TO UL DESIGN U425
1/2"COVER BOARD
POLYISOCYANURATE BOARD
INSULATION
VAPOR RETARDER
SUBSTRATE BOARD
ROOF DECKMIN6"1/2"VARIESTAPERED INSULATION
WHERE INDICATED ON ROOF
PLAN
PROVIDEDREQUIREDU-VALUE
2020 ECCCNYS-C402.1.4 THERMAL ENVELOPE
INSULATION COMPONENT MINIMUM
REQUIREMENTS - CLIMATE ZONE 6A -
INSULATION ENTIRELY ABOVE ROOF DECK
CONTINUOUS .029.032
• REFER TO STRUCTURAL DRAWINGS FOR ROOF FRAMING
• 1-HOUR RATED PER UL DESIGN P819 (1-HOUR SPRAY-
APPLIED FIREPROOFING)
• ROOFING SYSTEM: SEE ROOF PLAN
SPRAY-APPLIED
FIREPROOFING
LAMINATED BASE ROOFING
SHEET
2"DECORATIVE ROOFING
AGGREGATE / BALLAST
COLOR AND DESIGN TBD
STRETCH
.029
FULLY ADHERED MEMBRANE
ROOFING
5/8"
GYPSUM BOARD
PROVIDED
0.026
REQUIRED
0.064
U-FACTOR
2020 ECCCNYS-C402.1.4 OPAQUE THERMAL
ENVELOPE ASSEMBLY MAXIMUM
REQUIREMENTS - CLIMATE ZONE 6A - METAL
FRAMED WALL - OTHER THAN RESIDENTIAL
CFMF STUDS 24" OC (18
GAUGE)
• RATED AS REQUIRED BY CODE CONFORMANCE PLANS, UL DESIGN CW-D-1044 OR
APPROVED EQUAL
• NOTE: MULLION SIZES MAY VARY BY MANUFACTURER, COORDINATE FINAL SIZES
AND STEEL REINFORCING REQUIREMENTS WITH MANUFACTURER.
6"3"
GLAZED ALUMINUM CURTAIN
WALL ASSEMBLY
MINERAL-WOOL BOARD
INSULATION
1' - 4 1/2"
7 1/2"
STRETCH
0.047
MINERAL-WOOL BOARD
INSULATION
IMPALING PINS @ 12" OC,
BOTH SIDE OF BACKPAN
ALUMINUM BACKPAN, TYPICAL, UON
STEEL BACKPAN, 22 GA AT RATED
EXTERIOR WALL LOCATIONS
10"
COLUMN
CENTERLINE
2"
3" AT RATED EXTERIOR
WALL LOCATIONS
MINERAL-WOOL BATT INSULATION AT
RATED EXTERIOR WALL LOCATIONS
• NOTE: MULLION SIZES MAY VARY BY MANUFACTURER,
COORDINATE FINAL SIZES AND STEEL REINFORCING
REQUIREMENTS WITH MANUFACTURER
• TOTAL U-FACTOR: 0.XX (0.34 MAXIMUM)
• SHGC: .XX (.40 MAXIMUM)
GLAZING
ALUMINUM
STOREFRONT
FRAMING2"2"4 1/2"
FULLY ADHERED MEMBRANE
ROOFING
COVER BOARD
POLYISOCYANURATE BOARD
INSULATION
VAPOR RETARDER
SUBSTRATE BOARD
ROOF DECK1/2"6"5/8"2020 ECCCNYS-C402.1.4 THERMAL ENVELOPE
INSULATION COMPONENT MINIMUM
REQUIREMENTS - CLIMATE ZONE 6A -
INSULATION ENTIRELY ABOVE ROOF DECK
• REFER TO STRUCTURAL DRAWINGS FOR ROOF FRAMING
• 1-HOUR RATED PER UL DESIGN P819 (1-HOUR SPRAY-
APPLIED FIREPROOFING)
• ROOFING SYSTEM: SEE ROOF PLAN
SPRAY-APPLIED
FIREPROOFING
LAMINATED BASE ROOFING
SHEET
PROVIDEDREQUIREDU-VALUE
CONTINUOUS .029.032
STRETCH
.029
GLAZING
ALUMINUM CURTAIN
WALL FRAMING
• NOTE: MULLION SIZES MAY VARY BY MANUFACTURER,
COORDINATE FINAL SIZES AND STEEL REINFORCING
REQUIREMENTS WITH MANUFACTURER
• TOTAL U-FACTOR: 0.XX (0.34 MAXIMUM)
• SHGC: 0.XX (.40 MAXIMUM)
7 1/2"2 1/2"2 1/2"2"VARIES
CAST-IN-PLACE CONCRETE
MODIFIED BITUMINOUS
SHEET WATERPROOFING
POLYSTYRENE BOARD
INSULATIONBELOW GRADE2' - 0" MINPROVIDED
0.095
REQUIRED
0.119U-FACTOR
2020 ECCCNYS-C402.1.4 OPAQUE THERMAL
ENVELOPE ASSEMBLY MAXIMUM
REQUIREMENTS - CLIMATE ZONE 6A -
FOUNDATION WALL UNHEATED SLAB -
OTHER THAN RESIDENTIAL
STRETCH
1 1/4"
3 5/8"
SOLID GROUT
0.092
UNDISTURBED EARTH
CONCRETE SLAB
REFER TO FINISH PLANS
FOR FLOOR FINISH
VAPOR RETARDER
REFER TO STRUCTURAL DRAWINGS FOR FLOOR SYSTEM
STRUCTURAL FILL5"1' - 0"CFMF STUDS 24" OC
GLASS-MAT GYPSUM
SHEATHING
CONTINUOUS
VAPOR-PERMEABLE AIR
BARRIER SYSTEM
COMPOSITE
POLYISOCYANURATE BOARD
INSULATION, FASTEN TO
STUD
CONTINUOUS FRAME AND
CLIP, FASTEN THROUGH
COMPOSITE BOARD ONLY
COMPOSITE METAL PANEL
RAINSCREEN
WEATHER BARRIER
MINERAL WOOL
BATT INSULATION
2020 ECCCNYS-C402.1.4 THERMAL ENVELOPE
INSULATION COMPONENT MINIMUM REQUIREMENTS -
CLIMATE ZONE 6A - FLOORS, JOIST/FRAMING
5/8"3 1/2"1/2"6"PROVIDED
0.027
REQUIRED
0.064
U-FACTOR STRETCH
0.047
CFMF STUDS 24" OC
GLASS-MAT GYPSUM
SHEATHING
CONTINUOUS
VAPOR-PERMEABLE AIR
BARRIER SYSTEM
COMPOSITE
POLYISOCYANURATE BOARD
INSULATION, FASTEN TO
STUD
WEATHER BARRIER
MINERAL WOOL
BATT INSULATION
2020 ECCCNYS-C402.1.4 THERMAL ENVELOPE
INSULATION COMPONENT MINIMUM REQUIREMENTS -
CLIMATE ZONE 6A - FLOORS, JOIST/FRAMING
2X FR WOOD
FURRING @ 16" OC
1X6 TONGUE & GROOVE
WOOD SIDING, PREFINISHED3/4"1 1/2"5/8"3 1/2"1/2"6"PROVIDED
0.027
REQUIRED
0.047U-FACTOR
STRETCH
0.047
DATE:
PROJECT:
OTHER:
DRAWN BY:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
Architecture
Planning
Interior Design
11 12
H
I
11 12
H
I
619 West State Street
Ithaca, New York 14850
132 E. Jefferson Street
Syracuse, New York 13202
p 607 273 7600 www.holt.com
WARNING: It is a violation of New
York State Law for any person,
unless acting under the direction of
a licensed Architect, to alter this
document in any way. If a document
bearing the seal of an Architect is
altered, the altering Architect shall
affix to such document his seal and
the notation "altered by" followed by
his signature, the date of such
alteration, and a specific description
of the alteration.2/10/2021 2:34:02 PMA001
GENERAL
NOTES,
EXTERIOR
WALL & ROOF
SYSTEMS
02/05/2021
2018089
CRB/GLM Cayuga Park, Ithaca, New York 14850Park Grove - Cayuga Medical CenterMEDICAL OFFICE BUILDING1 ALL WORK IS NEW UNLESS NOTED AS EXISTING.
2 ANY DISCREPANCY CONTAINED WITHIN ANY OF THE DOCUMENTS SHALL BE
UNDERSTOOD TO MEAN THAT THE GREATER QUANTITY AND OR THE BETTER QUALITY
SHALL BE PROVIDED IN THE FAVOR OF THE OWNER.
3 REFER TO CODE CONFORMANCE DRAWINGS FOR REQUIRED FIRE RATED
CONSTRUCTION.
4 CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN FIELD (EXISTING
AND SCHEDULED CONSTRUCTION) AND NOTIFY THE ARCHITECT OF ANY
DISCREPANCIES.
5 DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONS.
6 NOTES ON ONE DETAIL OR DRAWING APPLY TO ALL SIMILAR DETAILS AND DRAWINGS.
7 DIMENSIONS NOTED "EQ" ARE EQUAL TO EACH OTHER ONLY IF THEY ARE ON THE
SAME DIMENSION STRING AND IN THE SAME ROW.
8 ROOM NUMBERING IS FOR CONSTRUCTION PURPOSES ONLY, ACTUAL ROOM
NUMBERING TO BE COORDINATED WITH THE OWNER PRIOR TO ANY SCHEDULING OR
LABELING. ALL EQUIPMENT LABELING AND SCHEDULING SHALL BE FORMATTED AS
DIRECTED BY OWNER.
9 ANY PORTION OF THE PROJECT WHICH IS DAMAGED AS A RESULT OF CONSTRUCTION
ACTIVITY SHALL BE REPAIRED.
GENERAL NOTES
1 1/2" = 1'-0"G5 EXTERIOR WALL SYSTEM TYPE 1 (EWS-1)
1 1/2" = 1'-0"G7 EXTERIOR WALL SYSTEM TYPE 2 (EWS-2)
1 1/2" = 1'-0"D6 ROOF SYSTEM TYPE 2 (RS-2)
1 1/2" = 1'-0"G9 EXTERIOR WALL SYSTEM TYPE 3 (EWS-3)
1 1/2" = 1'-0"A4 EXTERIOR STOREFRONT SYSTEM (ESF-1)
1 1/2" = 1'-0"D9 ROOF SYSTEM TYPE 1 (RS-1)
1 1/2" = 1'-0"A5 EXTERIOR CURTAIN WALL SYSTEM (ECW-1)
1 1/2" = 1'-0"A7 FOUNDATION WALL SYSTEM TYPE 1 (FWS-1)
1 1/2" = 1'-0"A9 FLOOR SYSTEM 2 (FS-2)
1 1/2" = 1'-0"D1 EXTERIOR CEILING SYSTEM 1 (CS-1)
1 1/2" = 1'-0"D4 EXTERIOR CEILING SYSTEM 2 (CS-2)
REVISION SCHEDULE
NAME DATE
Received by DiMarco 2/15/2021