HomeMy WebLinkAboutEC-003 Fire Rated Poke Throughs 053 - approvedSUBMITTAL COVER SHEET JOB: ITHACA COLLEGE PHYSICIAN’S ASSISTANT ROTHSCHILD RENOVATION SUBMITTAL NUMBER: 53 DATE: 2 MARCH 2021 SUBCONTRACTOR NAME: ARCHITECTURAL CONCRETE PLUS, LLC ARCHITECTURAL CONCRETE PLUS, LLC 69 HOLLISTER STREET DUNDEE, NY 14837 PHONE: 607-243-7113 FAX 315-423-0054 ACP PROJECT NO: 21-105 ARCHITECT: QPK 450 S SALINA ST STE 500, SYRACUSE, NY 13202 ARCHITECT PROJECT NO: 220157.00 (12/18/2020) TYPE OF SUBMITTAL: X PRODUCT DATA TEST REPORT SHOP DRAWING RECORD DOCUMENT SAMPLE CERTIFICATION MFGR COMPLIANCE CE CLOSEOUT DOCUMENT COLOR SELECTION MFGR DWG SUBSTITUTION MSDS SUBMITTAL DESCRIPTION 260533 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS SUPPLIER JOHN MILLS ELECTRIC MANUFACTURER HUBBELL SPEC SECTION NUMBER & TITLE 260533 SUB-PARAGRAPH DRAWING NO 1ST TIME SUBMISSION X REVISION PRIME CONTRACTOR’S STAMP/CERTIFICATION : I HEREBY CERTIFY THAT I HAVE REVIEWED THIS SUBMITTAL, VERIFIED THE PRODUCTS, VERIFIED FIELD MEASUREMENTS WHERE APPROPRIATE AND HAVE COORDINATED THE INFORMATION WITHIN THE SUBMITTAL WITH THE REQUIREMENTS OF CONTRACT DOCUMENTS. THE SUBMITTED ITEMS COMPLY IN EVERY RESPECT WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS AND SPECIFICATIONS ARCHITECT/ENGINEER REVIEW STAMP: PRIME CONTRACTOR/CONTRACT/BID PKG NO. SIGNED: POSITION: DATE: COMMENTS: 5HFHLYHG0&( X 3-12-21 SDM SUBMITTAL FORM Contractor: John Mills Electric, Inc. Address: 1836 Grand Central Ave. Elmira Heights, NY 14903 Ithaca College Physicians Assistance JME Job No. 20-2333 Submittal Number: EC-003 TYPE OF SUBMITTAL: DATE: 2/24/2021 Shop Drawing Schedule Sample Product Data Certificate Color Samples Test Report Warranty O & M Manual DESCRIPTION: Submittal Subject: Fire Rated Poke Throughs Spec. Section No.: Paragraph: Manufacturer: Hubble Supplier: ID Booth Contractor’s Comments: Contractor’s Stamp By Nick Wheeler Estimator / Project Manager Architect/Engineer’s Stamp Comments John Mills Electric 1836 Grand Central Ave. Elmira Heights, NY 14903 Table of Contents Ithaca College PA Program SKU Asset Type Page S1R8PTZZ1ALU Specifications 1 'LPHQVLRQVLQ,QFKHV PP +XEEHOO:LULQJ'HYLFH.HOOHPVs+XEEHOO,QFRUSRUDWHG 'HODZDUH s:DWHUYLHZ'ULYHs6KHOWRQ&7 3KRQH  s)D[  s6SHFLILFDWLRQVVXEMHFWWRFKDQJHZLWKRXWQRWLFH Fire-Rated Poke-Throughs SystemOne Recessed 8-Inch Diameter Core Hole Features One 3/4" EMT for Perimiter Power, One 1" EMT and One 1-1/2" EMT for Center Chamber S1R8CVRALU, Brushed Aluminum Cover Included Two S1R8PSPZ Pre-Wired Sub-Plates Included (not installed in Fitting) Junction Box Included Ordering Information Fire-Rated Poke-Through Fitting, (2) S1R8PSPZ and Cover Cover and Sub-Plates Installed Onsite Catalog Number UPC Number Cover Series Core Hole DiameterS1R8PTZZ1ALU783585443959 S1R8CVR 8-Inch Minimum Deck Thickness Connection Type2.25" Over Metal Deck Recessed Standards cULus & ULC ListedUL scrub water compliantADA Compliant Specifications Cover load rating 1000 lbs. static load through 3" diameter mandral Access cover material Die cast aluminum Fire Rating 1 - 2 Hour Fire Rating Required Covers and Sub-Plates Click here Accessories 8" Pre-Pour Tube, removed need for core hold drilling S1R8PPT Online Resources Customer Use Drawing eCatalog Installation Instructions