Loading...
HomeMy WebLinkAbout260100 EC-002 Gear Submittal 045 - App w NotSUBMITTAL COVER SHEET JOB: ITHACA COLLEGE PHYSICIAN’S ASSISTANT ROTHSCHILD RENOVATION SUBMITTAL NUMBER: 45 DATE: 15 FEBRUARY 2021 SUBCONTRACTOR NAME: ARCHITECTURAL CONCRETE PLUS, LLC ARCHITECTURAL CONCRETE PLUS, LLC 69 HOLLISTER STREET DUNDEE, NY 14837 PHONE: 607-243-7113 FAX 315-423-0054 ACP PROJECT NO: 21-105 ARCHITECT: QPK 450 S SALINA ST STE 500, SYRACUSE, NY 13202 ARCHITECT PROJECT NO: 220157.00 (12/18/2020) TYPE OF SUBMITTAL: X PRODUCT DATA TEST REPORT SHOP DRAWING RECORD DOCUMENT SAMPLE CERTIFICATION MFGR COMPLIANCE CE CLOSEOUT DOCUMENT COLOR SELECTION MFGR DWG SUBSTITUTION MSDS SUBMITTAL DESCRIPTION GEAR SUPPLIER JME MANUFACTURER VARIOUS SPEC SECTION NUMBER & TITLE 260100 / 260519 / 262813 SUB-PARAGRAPH DRAWING NO 1ST TIME SUBMISSION X REVISION PRIME CONTRACTOR’S STAMP/CERTIFICATION : I HEREBY CERTIFY THAT I HAVE REVIEWED THIS SUBMITTAL, VERIFIED THE PRODUCTS, VERIFIED FIELD MEASUREMENTS WHERE APPROPRIATE AND HAVE COORDINATED THE INFORMATION WITHIN THE SUBMITTAL WITH THE REQUIREMENTS OF CONTRACT DOCUMENTS. THE SUBMITTED ITEMS COMPLY IN EVERY RESPECT WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS AND SPECIFICATIONS ARCHITECT/ENGINEER REVIEW STAMP: PRIME CONTRACTOR/CONTRACT/BID PKG NO. SIGNED: POSITION: DATE: COMMENTS: 5HFHLYHG0&( X 2-20-21 SDM SUBMITTAL FORM Contractor: John Mills Electric, Inc. Address: 1836 Grand Central Ave. Elmira Heights, NY 14903 Ithaca College Physicians Assistance JME Job No. 20-2333 Submittal Number: EC-002 TYPE OF SUBMITTAL: DATE: 2/12/2021 Shop Drawing Schedule Sample Product Data Certificate Color Samples Test Report Warranty O & M Manual DESCRIPTION: Submittal Subject: Gear Submittal Spec. Section No.: Paragraph: Manufacturer: Schneider Electric Supplier: ID Booth Contractor’s Comments: Contractor’s Stamp By Nick Wheeler Estimator / Project Manager Architect/Engineer’s Stamp Comments John Mills Electric 1836 Grand Central Ave. Elmira Heights, NY 14903 Approved with Notations: Panelboards: General (remarks apply to all panelboards) o Provide enclosure trim in accordance with contract specifications (door-in- door type trim). o Prior to ordering, verify top or bottom incoming feeds. o Verify lugs are mechanical type and properly sized for incoming feeds. o Provide panelboard identification labels and circuit breaker directories. o Field alter branch circuit breaker arrangements to properly balance loads. Remarks for Individual Panels o Panel HP-1: ƒProvide 3 phase, 3 wire panelboard. ƒProvide 175A-3P circuit breaker in lieu of 90A-3P circuit breaker. ƒPrior to ordering, verify branch circuit breaker quantities/sizes and future circuit breaker provision space requirements. o Panel LP-1: ƒPrior to ordering, verify branch circuit breaker quantities/sizes and future circuit breaker provision space requirements. Please be aware that there has recent email correspondence regarding branch circuitry which will result in circuit breaker changes. Also, revised drawings were recently issued due to owner requested changes to the classroom 133 (first floor). ƒCoordinate EWH water heater voltages with MC. Coordinate disconnect switch requirements for all EWH’s with MC prior to ordering. o Panel LP-2: ƒPrior to ordering, verify branch circuit breaker quantities/sizes and future circuit breaker provision space requirements. Please be aware that there has recent email correspondence regarding branch circuitry which will result in circuit breaker changes. Also, revised drawings were recently issued due to owner requested changes to the second-floor clinical area. ƒCoordinate EWH water heater voltages with MC. Coordinate disconnect switch requirements for all EWH’s with MC prior to ordering. Transformers: General (remarks apply to all transformers) o Insulation class shall be 220 degree C system with 115 degree C rise above 40 degree C ambient temperature. o Finish color shall be ANSI 61 gray enamel. o Designation for 112.5kVA transformer shall read “XFMR T-2” Safety Switches: General (remarks apply to all safety switches) o Verify quantities prior to ordering. o Coordinate EWH water heater voltages with MC. Coordinate disconnect switch requirements for all EWH’s with MC prior to ordering. o In lieu of specified manual motor starters, E.C. has the option to provide adequately sized motor-rated snap switches in compliance with N.E.C. Coordinate exact requirements with other trades. Remarks for Individual Safety Switches o Disconnect “D-T-2S” ƒRevise designation for 400A fused disconnect to read “D-T-2S”. ƒSystem used shall be 4-wire (neutral is required). ƒProvide 400A fuses as required. PRINTED : 2/12/2021 7:06 AM Prepared By: Dwight Gleason BOOTH ELECTRIC SUPPLY INC 101 E Second St Elmira,NY 14901 dgleason@boothelectric.com D:6077339188 Proposal Name: ITHACA COLLEGE PHSYICIANS ASSIST P Quote Name: ITHACA COLLEGE PHSYICIANS ASSIST P ------------------------------------------------------------------------------------------------------------------------------------------------- Proposal Number: P-210118-2071338 Quote Number: Q-2248202 Through Addenda Number: 0 Sales Representative: Gregory Matyas Conditions of Sale This Quotation is subject to Coordinated Project Terms. See https://www.schneider-electric.us/en/download/document/0100PL0043 Quote is valid for 30 days. Quoted lead times are approximate and subject to change. Schneider Electric reserves the right to amend, withdraw or otherwise alter this submission without penalty or charge as a result of any event beyond its control arising from or due to the current Covid-19 epidemic or events subsequent to this epidemic / pandemic including changes in laws, regulations, by laws or direction from a competent authority. Clarifications and Exceptions PRINTED : 2/12/2021 7:06 AM TABLE OF CONTENTS Panelboards Low Voltage Transformers Safety Switches This Section Contains Products: Panelboards Proposal Name: ITHACA COLLEGE PHSYICIANS ASSIST P Quote Number: Q-2248202 Quote Name: ITHACA COLLEGE PHSYICIANS ASSIST P PRINTED : 2/12/2021 7:06 AM Seq # Qty Product Description 1 1 Designation : HP-1 Product Details 1-NF MB Panel (INTERIOR)-NF Panelboard Consisting of 480Y/277V 3Ph 4W 60Hz SCCR: 35kA Fully Rated Single Main: 400A/3P LH Circuit Breaker Incoming Conductors: 1 - #1 - 600,(2)#1 - 250 kcml Bus: 400A Rated Copper: Silver/Tin Plated CU Ground Bar 42 Circuit Interior Type 1,Box: 68H x 20W x 5.75D Incoming: Bottom Trim: Surface - Hinged Box Cat No: MH68 Front Cat No: NC68VSHR Ref. Drawing: PBA554HR Feeders: 1 - 125A/3P EGB 1 - 90A/3P EGB 2 - 70A/3P EGB 2 - 50A/3P EGB 2 - 40A/3P EGB 15 - 20A/1P EGB Prepared Space 1 - 25A/3P EGB Optional Features: Standard Panel (Box Ahead),Copper Solid Neutral,Copper Ground Bar 1-MH68-PANELBOARD ENCLOSURE 1-NC68VSHR-NF PNL HINGED TRIM SF.20WX68H,T-1 VENTED Estimated days to ship, excluding transit: 15 working days after customer release to manufacturer. See Conditions of Sale. Seq # Qty Product Description 2 1 Designation : LP-1 Product Details 1-NQ MB Panel (INTERIOR) - A-NQ Panelboard Consisting of 208Y/120V 3Ph 4W 60Hz SCCR: 10kA Fully Rated Single Main: 225A/3P QB Circuit Breaker Main Acc: Feed Thru Lugs Incoming Conductors: 1 - #4 - 300 kcmil Bus: 225A Rated Copper: Silver/Tin Plated CU Ground Bar 54 Circuit Interior Type 1,Box: 56H x 20W x 5.75D Incoming: Bottom Trim: Surface with Door Box Cat No: MH56 Front Cat No: NC56S Ref. Drawing: PBA707A Feeders: 2 - 40A/2P QOB 1 - 30A/2P QOB 4 - 20A/2P QOB 3 - 15A/2P QOB 2 - 30A/1P QOB 32 - 20A/1P QOB Optional Features: Standard Panel (Box Ahead),Copper Solid Neutral,Same Height Boxes,Copper Ground Bar Branch User Placement 1-MH56-PANELBOARD ENCLOSURE 1-NC56S-PANELBOARD COVER/TRIM NF TYPE 1 S 56H 1-NQ ML Panel (INTERIOR) - B-NQ Panelboard THIS WILL BE 175A Proposal Name: ITHACA COLLEGE PHSYICIANS ASSIST P Quote Number: Q-2248202 Quote Name: ITHACA COLLEGE PHSYICIANS ASSIST P Addendum: 0 Date: PRINTED : 2/12/2021 7:06 AM Consisting of 208Y/120V 3Ph 4W 60Hz SCCR: 10kA Fully Rated Main Lug Only: 225A Incoming Conductors: 1 - #4 - 300 kcmil Bus: 225A Rated Copper: Silver/Tin Plated CU Ground Bar 54 Circuit Interior Type 1,Box: 56H x 20W x 5.75D Incoming: Top Trim: Surface with Door Box Cat No: MH56 Front Cat No: NC56S Ref. Drawing: PBA701A Feeders: 32 - 20A/1P QOB 22 - 20A/1P QOB Prepared Space Optional Features: Standard Panel (Box Ahead),Copper Solid Neutral,Same Height Boxes,Copper Ground Bar Branch User Placement 1-MH56-PANELBOARD ENCLOSURE 1-NC56S-PANELBOARD COVER/TRIM NF TYPE 1 S 56H Estimated days to ship, excluding transit: 14 working days after customer release to manufacturer. See Conditions of Sale. Seq # Qty Product Description 3 1 Designation : LP-2 Product Details 1-NQ MB Panel (INTERIOR) - A-NQ Panelboard Consisting of 208Y/120V 3Ph 4W 60Hz SCCR: 22kA Fully Rated Single Main: 400A/3P LA Circuit Breaker Main Acc: Feed Thru Lugs Incoming Conductors: 1 - #1 - 600,(2)#1 - 250 kcml Bus: 400A Rated Copper: Silver/Tin Plated CU Ground Bar 42 Circuit Interior Type 1,Box: 68H x 20W x 5.75D Incoming: Bottom Trim: Flush - Hinged Box Cat No: MH68 Front Cat No: NC68VFHR Ref. Drawing: PBA710HR Feeders: 1 - 50A/3P QOB-VH 1 - 20A/2P QOB-VH 4 - 15A/2P QOB-VH 24 - 20A/1P QOB-VH 1 - 30A/2P QOB-VH 1 - 25A/2P QOB-VH 1 - 30A/1P QOB-VH Optional Features: Standard Panel (Box Ahead),Copper Solid Neutral,Same Height Boxes,Copper Ground Bar Branch User Placement 1-MH68-PANELBOARD ENCLOSURE 1-NC68VFHR (TRIM) - A-Trim Flush Hinged 68"H 1-NQ ML Panel (INTERIOR) - B-NQ Panelboard Consisting of 208Y/120V 3Ph 4W 60Hz SCCR: 22kA Fully Rated Main Lug Only: 400A Main Acc: Feed Thru Lugs Incoming Conductors: 1 - #1 - 600,(2)#1 - 250 kcml Proposal Name: ITHACA COLLEGE PHSYICIANS ASSIST P Quote Number: Q-2248202 Quote Name: ITHACA COLLEGE PHSYICIANS ASSIST P Addendum: 0 Date: PRINTED : 2/12/2021 7:06 AM Bus: 400A Rated Copper: Silver/Tin Plated CU Ground Bar 42 Circuit Interior Type 1,Box: 68H x 20W x 5.75D Incoming: Top Trim: Flush - Hinged Box Cat No: MH68 Front Cat No: NC68VFHR Ref. Drawing: PBA709HR Feeders: 42 - 20A/1P QOB-VH Optional Features: Standard Panel (Box Ahead),Copper Solid Neutral,Same Height Boxes,Copper Ground Bar Branch User Placement 1-MH68-PANELBOARD ENCLOSURE 1-NC68VFHR (TRIM) - B-Trim Flush Hinged 68"H 1-NQ ML Panel (INTERIOR) - C-NQ Panelboard Consisting of 208Y/120V 3Ph 4W 60Hz SCCR: 22kA Fully Rated Main Lug Only: 400A Incoming Conductors: 1 - #1 - 600,(2)#1 - 250 kcml Bus: 400A Rated Copper: Silver/Tin Plated CU Ground Bar 42 Circuit Interior Type 1,Box: 68H x 20W x 5.75D Incoming: Bottom Trim: Flush - Hinged Box Cat No: MH68 Front Cat No: NC68VFHR Ref. Drawing: PBA709HR Feeders: 23 - 20A/1P QOB-VH 18 - 20A/1P QOB-VH Prepared Space 1 - 15A/1P QOB-VH Optional Features: Standard Panel (Box Ahead),Copper Solid Neutral,Same Height Boxes,Copper Ground Bar Branch User Placement 1-MH68-PANELBOARD ENCLOSURE 1-NC68VFHR (TRIM) - C-Trim Flush Hinged 68"H Estimated days to ship, excluding transit: 14 working days after customer release to manufacturer. See Conditions of Sale. Features s 96ACMAXIMUM s !MAXIMUMMAINCIRCUITBREAKER !MAXIMUMMAINLUGS s  !THROUGH !3##2 s3UB FEEDCIRCUITBREAKERSAREVERTICALLYMOUNTED s !MAXIMUMBRANCHMOUNTEDCIRCUITBREAKERS!FOR96 s)NTERIORSARElELDCONVERTIBLETOTOPORBOTTOMFEED s"OLT ONBRANCHCIRCUITBREAKERSATTACHWITHCAPTIVESCREWS s6ISI 4RIP®INDICATIONONBRANCHCIRCUITBREAKERS s 3UITABLEFORUSEASSERVICEEQUIPMENT s#OMPLETELINEOF5,C5,LISTEDINTERIORSWITHRATEDNEUTRALSFOR NON LINEARLOADS s WIDETRIMSANDBOXESCOMMONFOR.&AND.1PANELBOARDS s -ONO mATORHINGEDTRIMS s 6ERTICALLYMOUNTEDMAINBREAKERSAVAILABLE ALLAMPERAGES s"RANCHCIRCUITlLLERPLATESPROVIDEFASTANDEASYINSTALLATION The NF panelboard offers superior performance and application flexibility for commercial and industrial electrical systems up to 600Y/347Vac. This versatile lighting and power distribution panelboard features a wide selection of circuit breakers, accessories and ready-to-install kits, as well as 200% rated neutrals for non-linear loads. Factory Options s07OR07n!MAINLUGSAND! MAINBREAKERPANELBOARDS s 3UB FEEDANDTHRU FEEDLUGS s 3UB FEEDCIRCUITBREAKERS s /PTIONALRATEDNEUTRALSTHROUGH! s 3PLITBUSBARS s 4633  !n !SURGECURRENTRATING !LLVOLTAGESYSTEMS s ,IGHTINGCONTACTORS s#USTOMEREQUIPMENTSPACE y p s 07OR07n!MAINLUGSAND MAINBREAKERPANELBOARDS s 3UB FEED AND THRU FEED LUGS Factory Options NF Lighting Panelboards “Ready-to-Install” Panels and Kits Available from Stock s !n!-,/07INTERIORS s4YPEAND2ENCLOSURES s !n!MAINCIRCUITBREAKERKITS s  !OR !SURGECURRENTRATINGS s !n!SUB FEEDANDTHRU FEEDLUGS s 3UB FEEDCIRCUITBREAKERKITS n!SUB FEEDCIRCUITBREAKERPER!PANELBOARD n!SUB FEEDCIRCUITBREAKERSPER!OR!PANELBOARD s NEUTRALKITSUPTO! s #OPPERNEUTRALSANDEQUIPMENTGROUNDBARS NQ Lighting Panelboards Developed with electrical contractor input, the NQ family of lighting and appliance panelboards sets new standards for ease of installation and durability. Plus, new design innovations increase the availablity of these panelboards by offering complete ready to install products. Features s6AC 6DCMAXIMUM s !MAXIMUMMAINCIRCUITBREAKERSORMAINLUGS s !MAXIMUMBRANCHCIRCUITBREAKERS s  !THROUGH !3##2 s"OTHFULLYRATEDANDSERIESRATEDSYSTEMSAREAVAILABLE s )NTERIORSARElELDCONVERTIBLETOTOPORBOTTOMFEED s)NTERIORSAREAVAILABLEINPLATEDCOPPERORALUMINUMBUS s )NTERIORSACCEPTBOTHBOLT ONANDPLUG ONBRANCHCIRCUITBREAKERS s #OMPLETELINEOF5,C5,LISTEDINTERIORSWITHRATEDNEUTRALSFORNON LINEARLOADS s3UITABLEFORUSEASSERVICEENTRANCEEQUIPMENT s WIDETRIMSANDBOXESCOMMONFOR.1AND.&PANELBOARDS s-ONO mAT®ORHINGEDTRIMS “Ready-to-Install” Panels and Kits Available from Stock s!n!-,/07AND07)NTERIORS s.%-!AND2ENCLOSURES s!n!MAINCIRCUITBREAKERKITS s4633INTERIORS  !OR !SURGECURRENTRATINGS s !n!SUB FEEDANDTHRU FEEDLUGS s 3UB FEEDCIRCUITBREAKERKITS n!SUB FEEDCIRCUITBREAKERPER!PANELBOARD n!SUB FEEDCIRCUITBREAKERSPER!PANELBOARD s NEUTRALKITSUPTO! s #OPPERNEUTRALSANDEQUIPMENTGROUNDBARS Factory Options s07OR07n!MAINLUGSAND MAINBREAKERPANELBOARDS s 3UB FEEDANDTHRU FEEDLUGS s 3UB FEEDCIRCUITBREAKERS s/PTIONALRATEDNEUTRALSUPTO! s 3PLITBUSBARS s4633  !n !SURGECURRENTRATING !LLVOLTAGESYSTEMS s,IGHTINGCONTACTORS s#USTOMEREQUIPMENTSPACE This Section Contains Products: Low Voltage Transformers Proposal Name: ITHACA COLLEGE PHSYICIANS ASSIST P Quote Number: Q-2248202 Quote Name: ITHACA COLLEGE PHSYICIANS ASSIST P PRINTED : 2/12/2021 7:06 AM Seq # Qty Product Description 8 1 Designation : XFMR T1 Product Details 1-EXN75T3HCU-TRANSFORMER DRY TYPE 75KVA 480D208Y CU Transformer Type: DOE 2016 EX or EXN Transformer Rating: 75kVA Transformer Phase: Three Phase Primary Voltage: 480V Delta Secondary Voltage: 208Y/120V Transformer Taps: 6 - 2.5% 2+4- Taps Frequency: 60Hz Transformer Winding Material: Copper Sound Level: 44DB Insulation & Temperature: Class 220 (H), 150 Deg C Enclosure Material: Standard Painted ANSI 49 Grey UL Labeled Seq # Qty Product Description 9 1 Designation : Product Details 1-EXN112T3HCU-TRANSFORMER DRY TYPE 112.5KVA 480D208Y Transformer Type: DOE 2016 EX or EXN Transformer Rating: 112.5kVA Transformer Phase: Three Phase Primary Voltage: 480V Delta Secondary Voltage: 208Y/120V Transformer Taps: 6 - 2.5% 2+4- Taps Frequency: 60Hz Transformer Winding Material: Copper Sound Level: 44DB Insulation & Temperature: Class 220 (H), 150 Deg C Enclosure Material: Standard Painted ANSI 49 Grey UL Labeled This Section Contains Products: Safety Switches Proposal Name: ITHACA COLLEGE PHSYICIANS ASSIST P Quote Number: Q-2248202 Quote Name: ITHACA COLLEGE PHSYICIANS ASSIST P PRINTED : 2/12/2021 7:06 AM Seq # Qty Product Description 4 1 Designation : D-T-25 Product Details 1-H365-SWITCH FUSIBLE HD 600V 400A 3P NEMA 1 Enclosure Type: Type 1 Interrupting Rating (AIR): 200kA Fuse Capability: Class R Max System Voltage: 600Vac Switch Current Rating: 400A System Used: 3 Wire (3 Blades/Fuseholder) Neutral Kit: H600SN Ground Lug: PKOGTA2 Processed by ACE 2.0 - 04172018 1-H600SN-NEUTRAL ASSEMBLY INSULATED GROUNDABLE 1-PKOGTA2-EQUIPMENT GROUND KIT Seq # Qty Product Description 10 2 Designation : Product Details HU362RB-HEAVY DUTY GENERAL SAFETY SWITCH Seq # Qty Product Description 11 3 Designation : Product Details HU361RB-HEAVY DUTY GENERAL SAFETY SWITCH Seq # Qty Product Description 5 1 Designation : D-T-1P Product Details 1-HU364N-SW NOT FUSIBLE HD 200A 3P NEMA1/NEUTRAL Enclosure Type: Type 1 Fuse Capability: Non-Fused Max System Voltage: 600Vac Switch Current Rating: 200A System Used: 4 Wire (3 Blades/Fuseholder, 1 Neutral) Neutral Kit: Factory Installed Ground Lug: PKOGTA2 Processed by ACE 2.0 - 04172018 1-PKOGTA2-EQUIPMENT GROUND KIT Seq # Qty Product Description 9 1 Designation : EWH-1 Product Details 1-HU361-HEAVY DUTY GENERAL SAFETY SWITCH Enclosure Type: Type 1 Fuse Capability: Non-Fused Max System Voltage: 600Vac Switch Current Rating: 30A System Used: 3 Wire (3 Blades/Fuseholder) Ground Lug: GTK03 Processed by ACE 2.0 - 04172018 1-GTK03-ALUMINUM GROUND KITS Power isolation solutions for daily activities and emergencies Square D Safety Switches Make the most of your energySM TM Setting the standard for perfomance, quality, and reliability in today’s commercial and industrial applications First introduced in 1907, Square D™ by Schneider Electric™ safety switches have a long history of leadership in safety and performance. Since then, Schneider Electric has pioneered many innovations to help maximize the lifetime value of your safety switches. Safety switches play a crucial role in today’s commercial and industrial settings. They isolate power in daily activities and provide an effective way to interrupt power in an emergency. Two primary applications for safety switches are as a lockout on sight disconnect and as a circuit isolation device. Square D Safety Switches 2 * Occupational Safety and Health Administration (OSHA) compliance. Key Customer Applications Sight Disconnect for Motors* Branch Circuit Protection Service Entrance Industrial Facilities XX Retail Construction XXX Water Wastewater XXX Data Centers XX Automotive XX Packaging XX Pharmaceutical, Food, Beverage XX Commercial OEM XX Square D safety switches are designed to outperform other switches in a wide range of demanding applications. Three Times the Life — Three Times the Value The performance of safety switches is important to the safe and profitable operation of many industrial settings. In addition, requirements from organizations such as OSHA have increased the use of safety switches in many commercial and industrial facilities. The useful life of a safety switch is less than two years based on NEMA® KS-1 life test requirements, in lockout/tag out applications where a switch is operated just once per hour, 24 hours a day, seven days a week. For switches in these high-use applications, durability is key. Square D safety switches provide significantly higher levels of mechanical endurance than NEMA KS-1 require. This translates to improved reliability in a production environment. In fact, the standard for the design life of Square D F-Series safety switches is a minimum of three times the NEMA requirement. No competitor comes close to the performance offered by Square D safety switches. Performance Designed for the Best Performance A key performance benefit of the Square D safety switch is its ability to break load. A locked motor can draw six to eight times motor full-load current. In an emergency situation, it’s important to have a switch with enhanced load break capability. A key element of Square D safety switches is their blade and jaw construction designs built to easily manage heavy motor loads and arc interruptions. 3 (1) Life determination based on 50,000 operations for Square D F-Series 30 A and 15,000 operations for competition. Actual number of operations will vary based upon electrical load, duty cycle, and environmental conditions. (2) Does not include cost of lost productivity. Switch cost replacement: labor = 2 hour @ $45/hour cost of switch @ $100. Maximum usable life of switch assumed to be 20 years. Potential Cost Avoidance Due to Square D Switch Life Operations of switch/ 8-hour shift Operations per year in 24/7 environment Life of Square D switch in years (1) Life of competitive switch in years (1) Cost avoidance by using Square D (2) 1 1,095 45.7 13.7 $190 2 2,190 22.8 6.8 $380 3 3,285 15.2 4.6 $570 4 4,380 11.4 3.4 $760 5 5,475 9.1 2.7 $950 Safety First Square D safety switches are, above all else, built to increase safety. Visible blades are an important feature, and they must be visible in real-world conditions to visually verify that the downstream circuit is de-energized. Our switch blades are easily visible, even in the less-than-ideal lighting conditions where electrical equipment is often installed. An optional view window adds another degree of safety through visual verification of switch position without the need to open the door. In addition, the design of the Square D safety switch includes an oversized arc suppressor, a key feature in the ability of the switch to break the load by effectively attenuating the arc for a clean interruption. Designed for Long-Term Durability Rugged construction and corrosion protection provide the industry’s longest lasting switches. Galvannealed steel in all single-throw Type 3R and 12 enclosures provides superior corrosion protection. Type 4X seam-welded enclosures help extend equipment life by providing excellent environmental and corrosion protection without the use of a silicone sealer, which can be incompatible with some manufacturing processes. Managing temperatures inside the switch is essential to providing greater service life. Square D safety switches feature more copper than other switches available on the market today. This larger amount of copper is one of the reasons Square D safety switches have lower operating temperatures. Heat is not the only factor that impacts switch life. The enclosed operating mechanism design of Square D safety switches reduces the amount of dust and other contaminants that shorten the mechanism’s operating life. Quality A Full Range of Accessories Square D safety switches feature a complete offering of accessories, available either factory- installed or field-installable. Factory-installed options include key interlocks, nameplates, push buttons, and optional safety colors. Field-installable accessory options include neutral kit, ground lugs, electrical interlocks, Class “R” fuse rejection kits, compression terminals, and conduit hubs. Efficient Installation Our time-saving design features make installation quick and easy. Square D safety switches feature quick-release cover latches that are easier to operate than screw- fasteners. On Type 4X and Type 12 switches, this design feature ensures a better gasket seal — a critical feature in adverse operating conditions — than is available with designs that rely on screw- fastened covers. Tangential knock-outs enable easier installation of conduit, without the need for costly, time-consuming offsets and bends. Mechanical Endurance Requirements for UL, NEMA, and F-Series Switches 4 Short-Circuit Current Ratings UL Listed Fuse Class General-Duty RMS Sym Amps Heavy-Duty RMS Sym Amps Plug 10,000 N/A H 10,000 10,000 K 10,000 10,000 J 100,000 200,000 R 100,000 200,000 T 100,000 200,000 L — 200,000 * Single-throw switches only. ** Actual number of operations may vary based on environmental conditions. Number of Operations** Switch Rating (Amps) UL 98 NEMA KS 1 General-Duty NEMA KS 1 Heavy-Duty E-Series Reqmts. 30 and 60 10,000 10,000 15,000 50,000 100 10,000 10,000 14,000 50,000 200 8,000 8,000 12,000 36,000* Cost-Saving Maintenance Advanced maintenance features extend switch life and reduce downtime, saving both labor and material costs. The Square D safety switch modular design allows the replacement of all interior worn or damaged components. Field-replaceable components such as interior line bases, load bases, and mechanisms are available. Moreover, handles and lock plates are also replaceable if they are damaged or vandalized. In addition, Square D Type 4X and 12 safety switches come standard with fuse pullers, increasing the convenience and safety of maintenance. Fuse pullers are also field-installable on certain models. Operation and Safety Nothing is as important in the design of a switch as understanding how it will be used. To ensure Square D safety switches continue to meet the needs of commercial and industrial applications, products are engineered with the operational procedures and safe work practices of customers in mind. Superior Handle Design The Square D F-Series insulated switch handle is an industry exclusive. It is made from a high-strength polymer chosen for weather resistance, durability, and impact strength. The two-color, position-indicating handle on heavy- duty safety switches enhances operator safety by aiding in visual recognition of switch position from an angle or at a distance. The simple concept of having contrasting colors on the handle enhances the ability of the operator to determine quickly the position of the switch, even in low-light conditions. In an emergency, it is vital that switch position be accurately recognizable. Plus, an embossed on/ off marking is a permanent indication of the switch position and cannot be removed or vandalized. Reliability 5 Tamper-Resistant Enclosure Resolving lockout issues is a priority with major industrials. Square D F-Series safety switches have an extruded lock plate feature that helps prevent tampering with lockout devices. The lock plate opening is extruded to reduce the possibility of lockout devices being removed by non- authorized personnel. With the use of the handle lock plate, the switch can be locked in the OFF position with up to three padlocks to comply with OSHA lockout requirements. The safety switch can also be modified so that the switch can be locked in the ON position, if required by the application. Heavy-duty dual cover interlocks are key safety features on single-throw and double-throw heavy- duty switches. These prevent the opening of the cover when the switch is ON or turning the switch ON when the cover is open. Qualified personnel can also defeat this feature allowing them to perform any necessary testing. Catalog Numbering System for Safety Switches For Types 7 and 9 construction, see the latest catalog listing. EI or EI2 = Factory-installed electrical interlock CLR = Class R fuse kits FP = Fuse pullers GL = Ground lugs SLC = Copper lugs LK = Compression lugs SPLO = Lock on VW = Viewing window NP = Phenolic legend plate KI = One-key interlock KIKI = Two-key interlocks WA = Appleton Powertite® interlocked receptacle WC = Crouse-Hinds Arktite® interlocked receptacle WH = Hubbellock® interlocked receptacle D321NRB Enclosure tNo Suffix = Type 1 tA = Type 12K tAWK = Type 12 (without knock-out) tDS = Types 4, 4X, 5 (304 stainless steel) tSS = Types 4, 4X, 5 (316 stainless steel) tCS = Cast aluminum tDX = Type 4X Krydon® — Crouse-Hinds® tR = Type 3R tRB = Type 3R (Type B hub provision) tDF = Type 4X fiberglass reinforced polyester Neutral N = Factory-installed neutral (neutrals are field-installable on most general-duty and heavy-duty safety switches) Ampere Rating 1 = 30 A 2 = 60 A 3 = 100 A 4 = 200 A 5 = 400 A 6 = 600 A 7 = 800 A 8 = 1,200 A Voltage Rating 1 = 120 Vac (Plug fuse) 2 = 240 Vac 6 = 600 Vac For DC ratings, see the latest catalog listing. Blades Switchable Poles 1 = One-pole 2 = Two-pole 3 = Three-pole 4 = Four-pole 6 = Six-pole Type of Switch Fusible: Miscellaneous 6 L = Light-Duty D = General-Duty H = Heavy-Duty DT = Double-Throw Non-fusable: DU = General-Duty HU = Heavy-Duty DTU = Double-Throw 7 Square D MD Enclosed Motor Disconnect Switch NEMA 4X Enclosed Switches Listed Maximum Horsepower Ratings Catalog Number Three-Phase 220 – 240 Vac 440 – 480 Vac 600 Vac UL 508 7.5 20 25 MD3304X UL 508 20 40 40 MD3604X 30 A Enclosed Switch Mounting Diagram 60 A Enclosed Switch Mounting Diagram Accessories Description Catalog Number Two normally open auxiliary contact modules MDSAN20 One normally open + one normally closed auxiliary contact modules MDSAN11 Additional power pole — 30 A MDS30P The Most Complete Line of Switches in the Industry Amp Range Vac Max. Vdc Max. Fusible Enclosure Type General-Duty 30 – 800 240 — Fusible and Non-Fusible Type 1, 3R Heavy-Duty 30 – 1,200 600 600 Fusible and Non-Fusible Type 1, 3R, 4, 4X Stainless Steel, 5, 12 Four-Pole Heavy-Duty 30 – 600 600 600 Fusible and Non-Fusible Type 1, 3R, 4X Stainless Steel, 12 Six-Pole Heavy-Duty 30 – 200 600 — Fusible and Non-Fusible Type 1, 3R, 4X Stainless Steel, 12 Double-Throw 30 – 100 600 600 Fusible and Non-Fusible Type 1, 3R, 4X Stainless Steel, 12 Double-Throw 200 – 600 600 250 Non-Fusible Type 1, 3R, 4X Stainless Steel, 12 Interlock Receptacle Switches (1) (2) 30 – 100 600 250 Fusible and Non-Fusible Type 1, 3R, 4, 4X Stainless Steel, 5, 12 Hazardous Location Switches 60 – 225 600 250 Non-Fusible Type 7 and 9 — Divisions 1 and 2 of the following: Class 1, Groups C and D, Class 2, Groups E and F; on Class 3, Hazardous Locations as defined in NEC® Article 500 (1) Appleton Powertite, Crouse-Hinds Arktite, and Hubbellock receptacles. (2) The MD motor disconnect switch serves as a local on/off switch for a motor when the motor branch circuit protection is in a central enclosure. It is in a compact NEMA 4X enclosure and is available in 30 A and 60 A versions. Type 1 (indoor), Type 3R (outdoor), Type 4, 4X, 5 (watertight and dust-tight, corrosion-resistant) (cast aluminum, stainless steel, glass polyester, or Krydon), Type 12 (mill and foundry type). Switches are UL Listed (UL 98 Enclosed Switches) and meet or exceed the NEMA KS1 standard unless otherwise noted. Document Number 3100BR9801R09/12 Schneider Electric USA, Inc. 1415 S. Roselle Road Palatine, IL 60067 Tel: 847-397-2600 Fax: 847-925-7500 www.schneider-electric.com/us February 2013 ©2013 Schneider Electric. All Rights Reserved. Schneider Electric, Square D, and Make the most of your energy are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All other trademarks are property of their respective owners. 998-1181593_USFor more information, visit www.schneider-electric.com/us and enter key code y290v.SETV Enter key code This Section Contains Products: Contactors and Starters Proposal Name: ITHACA COLLEGE PHSYICIANS ASSIST P Quote Number: Q-2248202 Quote Name: ITHACA COLLEGE PHSYICIANS ASSIST P PRINTED : 2/12/2021 7:06 AM Seq # Qty Product Description 5 10 Designation : HRB (1-10) Product Details 2510FG2P-MANUAL STARTER 277VAC Seq # Qty Product Description 6 1 Designation : EF-1 Product Details 2510FR1-MANUAL STARTER 277VAC Seq # Qty Product Description 7 39 Designation : AC (1-38) Product Details 2510FG2P-MANUAL STARTER 277VAC PILOT LIGHT NOT AN OPTION FOR NEMA 3R MANUAL MOTOR STARTER CRW of JME © 2005 Schneider Electric all rights reserved OVERLOAD RELAY TIME-CURRENT CHARACTERISTICS REFERENCE DRAWING NO. 30068-447 The trip current rating can be determined from the instructions given with the appropriate thermal unit selection table. The characteristics shown do not necessarily apply to equipment manufactured before the date of the referenced drawing. Relay Design Melting Alloy Thermal Unit Types A.49–A25.2 40 °C ambient cold start trip time characteristics of: Equipment AC Manual Starter Size FHP Type F Qty. of Thermal Units 1 When installed in: • Small enclosure (Class 2510 only) • Hinged door and all other (larger) enclosures Curve No. 2510TC0304May 20051MULTIPLES OF TRIP CURRENT RATING MULTIPLES OF TRIP CURRENT RATING.5.6.7.8.91.5234567891015201.5.6.7.8.91.523456789101520200 300 400 500 600 700 800 900 1000 1500 2000 3000 4000 6000 7000 8000 9000 5000 10000 1 1 1.5 2 3 4 5 6 7 8 9 10 1.5 2 3 4 5 6 7 8 9 10 15 20 30 40 50 60 70 80 90 100 15 20 30 40 50 60 70 80 90 100 150 200 300 400 500 600 700 800 900 1000 1500 2000 3000 4000 5000 6000 7000 8000 9000 10000 TIME IN SECONDSTIME IN SECONDS150 40 ˚C (104 ˚F) AMBIENT COLD START MAXIMUM AVERAGE Product datasheet Characteristics 2510FG2P Main Product or component type Single Unit Manual Starter Range of product F Thermal overload type Melting alloy Complementary Line Rated Current 16 A Cable entry 0.5" and 0.75" knock-outs (top and bottom) Motor power hp 1 hp at 115 V AC 1 hp at 277 V AC 0.75 hp at 115 V DC 0.75 hp at 230 V DC 2 hp at 230 V AC System Voltage 277 V AC 230 V DC Poles description 2P Control type Toggle switch Phase 1 phase Local signalling Red indicator Reset Manual Motor starter type Non reversing Electrical connection Screw clamp terminals AWG gauge AWG 14...AWG 12 (copper) Height 4.25 in Width 2.44 in Depth 2.75 in Environment product certifications CE UL listed file E42243 CCN NLRV CSA LR25490 class 3211 05 NEMA degree of protection NEMA 1 plastic standard size Offer Sustainability Not Green Premium product Not Green Premium product Will not be Compliant Will not be Compliant WARNING: This product can expose you to chemicals including: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.1 / 1 Product datasheet Characteristics 2510FR1H Main Product or component type Single Unit Manual Starter Range of product F Thermal overload type Melting alloy Complementary Line Rated Current 16 A Cable entry 0.75 NPT (top and bottom) Motor power hp 1 hp at 115 V AC 1 hp at 230 V AC 1 hp at 277 V AC System Voltage 277 V AC Poles description 1P Control type Toggle switch (with lock-off) Phase 1 phase Local signalling No indicator Reset Manual Motor starter type Non reversing Electrical connection Screw clamp terminals AWG gauge AWG 14...AWG 12 (copper) Height 6.36 in Width 3.95 in Depth 4.35 in Environment product certifications CE UL listed file E58760 CCN NPXZ CSA LR26817 class 3218 04 NEMA degree of protection NEMA 3R/7/9 cast aluminium standard size Offer Sustainability Not Green Premium product Not Green Premium product Will not be Compliant Will not be Compliant WARNING: This product can expose you to chemicals including: WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.1 / 1 PILOT LIGHT NOT AN OPTION FOR NEMA 3R MANUAL MOTOR STARTER CRW of JME