HomeMy WebLinkAbout233313 DAMPERS AND ACCESSORIES RESUBMITTAL 039 - APP W NOTSUBMITTAL COVER SHEET JOB: ITHACA COLLEGE PHYSICIAN’S ASSISTANT ROTHSCHILD RENOVATION SUBMITTAL NUMBER: 39 DATE: 12 FEBRUARY 2021 SUBCONTRACTOR NAME: ARCHITECTURAL CONCRETE PLUS, LLC ARCHITECTURAL CONCRETE PLUS, LLC 69 HOLLISTER STREET DUNDEE, NY 14837 PHONE: 607-243-7113 FAX 315-423-0054 ACP PROJECT NO: 21-105 ARCHITECT: QPK 450 S SALINA ST STE 500, SYRACUSE, NY 13202 ARCHITECT PROJECT NO: 220157.00 (12/18/2020) TYPE OF SUBMITTAL: X PRODUCT DATA TEST REPORT SHOP DRAWING RECORD DOCUMENT SAMPLE CERTIFICATION MFGR COMPLIANCE CE CLOSEOUT DOCUMENT COLOR SELECTION MFGR DWG SUBSTITUTION MSDS SUBMITTAL DESCRIPTION DAMPERS AND ACCESSORIES SUPPLIER KIMBLE MANUFACTURER VARIOUS SPEC SECTION NUMBER & TITLE 233313 SUB-PARAGRAPH DRAWING NO 1ST TIME SUBMISSION REVISION PRIME CONTRACTOR’S STAMP/CERTIFICATION : I HEREBY CERTIFY THAT I HAVE REVIEWED THIS SUBMITTAL, VERIFIED THE PRODUCTS, VERIFIED FIELD MEASUREMENTS WHERE APPROPRIATE AND HAVE COORDINATED THE INFORMATION WITHIN THE SUBMITTAL WITH THE REQUIREMENTS OF CONTRACT DOCUMENTS. THE SUBMITTED ITEMS COMPLY IN EVERY RESPECT WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS AND SPECIFICATIONS ARCHITECT/ENGINEER REVIEW STAMP: PRIME CONTRACTOR/CONTRACT/BID PKG NO. SIGNED: POSITION: DATE: COMMENTS: 5HFHLYHG0&(  X 2-24-21 SDM 0HFKDQLFDO&RQWUDFWLQJ([FHOOHQFH 6XEPLWWDO/RJ  6XEPLWWDO&RYHU6KHHW)RU   ,7+$&$&2//(*( 3$352*5$0 527+6&+,/'5(129$7,21 .LPEOH-RE&      'DWHRI6XEPLWWDO 1XPEHU2I &RSLHV  7KLV6XEPLWWDO3DJH  2I   68%  6SHF6HFWLRQ  'HVFULSWLRQ                         ,WLVWKHLQWHQWRI.LPEOH,QF7RSURYLGHHTXLSPHQWDQGPDWHULDOV WKDWPHHWVRUH[FHHGVWKHUHTXLUHPHQWVRIWKHFRQWUDFWGRFXPHQWV 7KLVVXEPLWWDOKDVEHHQ³UHYLHZHG´DQG³DSSURYHG´E\  *5(*),&$552 'DWH   H-7 233313 DAMPERS AND ACCESSORIES 2/22/21 RESUBMITTAL 2/22/21 6412 Baird Ave. Syracuse,NY 13206 Phone: (315) 471-0105 cfisher@rfpeck.com Equipment Submittal - REVISED Project Rothschild Renovation Ithaca College Physician Assistant Program Architect QPK Design Syracsue, NY Engineer Murphy Consulting Engineering Moravia, NY Contractor Southerntier Custom Fabricators Elmira, NY Submitted by Chris Fisher – 01/10/21, Revised 02/19/21 Manufacturer’s Representatives for Heating, Ventilating and Air Conditioning Equipment Contents: Pottorff – Fire Dampers Specification: 233313 SUBMITTAL Information is subject to change without notice or obligation.Note: Dimensions in parentheses ( ) are millimeters. 5101 Blue Mound Rd, Fort Worth TX 76106 Page 1 of 3 PROJECT:ITHACA COLLEGE PA PROGRAM LOCATION:Ithaca, NY SUBMITTED BY:R.F. PECK CO.- SYRACUSE 6412 Baird Ave Syracuse, NY 13206 PHONE:315-471-0105 FAX:1-315-471-2045 CUSTOMER:Southerntier Custom Fabricator ENGINEER:Murphy Consulting Engineering ARCHITECT:QPK Design SPECIFICATIONS:233313 DATE:2/19/2021 ITEMS Fire Dampers ENCLOSED:VFD-10 Installation Instructions FD operation and maintenance, VFD-10, VFD-10D, Sleeve terminations, Design I503, Project:Ithaca College PA Program Submittal Date:2/19/2021 Submitted By: This submittal sheet reflects only the construction and options selected and is not indicative of all constructions and options that are available for the product. For more information, please contact your local representative or visit us at www.pottorff.com. Information is subject to change without notice or obligation.Note: Dimensions in parentheses ( ) are millimeters. 5101 Blue Mound Rd, Fort Worth TX 76106 Page 2 of 3 Submittal Model VFD-10 Fire damper, 1-1/2 hour, static rated, curtain blade General construction Dimensions: Nominal (approximately 1/4" (6) undersize, sleeve thickness not included)Material: Galvanized steel Frame: 22 gauge Blade style: 24 gauge, curtain Fire closure device: Fusible link Fire closure temperature (°F): 165 Options Application mount: Vertical or horizontal Style: B Sleeve: Type: Sleeve; Length (in): 12; Gauge: 14; Clearance (in):3.5 Angles: Type: Picture frame, 16 ga (2 sides) Ratings UL 555 fire resistance rating: 1-1/2 hour (vertical and horizontal) UL HNLJ.V-5: Ventilation Duct Assemblies Listings UL 555 listing: R11767 CSFM listing: 3225-0368:101 Model VFD-10-B with sleeve Model VFD-10-BMultiple section units supplied as a single assembly. Dampers shown as vertical mount. Horizontal mount supplied in the same orientation. Details Line Item Tag Qty Duct(in.xxxx) Sections Damper assembly(in.xxxx) W x H D Wide x High W x T (in) 1 Rm 106 2 14 x 14 1 x 1 14 x 16 Notes: Dwg M-101 2 Rm 132 2 16 x 14 1 x 1 16 x 16 Notes: Dwg M-101 3 Rm 132 1 12 x 12 1 x 1 12 x 14 Notes: Dwg M-101 COORDINATE REQUIRED DUCT CHASE ACCESS DOORS WITH G.C. Project:Ithaca College PA Program Submittal Date:2/19/2021 Submitted By: This submittal sheet reflects only the construction and options selected and is not indicative of all constructions and options that are available for the product. For more information, please contact your local representative or visit us at www.pottorff.com. Information is subject to change without notice or obligation.Note: Dimensions in parentheses ( ) are millimeters. 5101 Blue Mound Rd, Fort Worth TX 76106 Page 3 of 3 Submittal Model VFD-10 Fire damper, 1-1/2 hour, static rated, curtain blade General construction Dimensions: Nominal (approximately 1/4" (6) undersize) Material: Galvanized steel Application mount: Vertical Frame: 22 gauge Blade style: 24 gauge, curtain Fire closure device: Fusible link Fire closure temperature (°F): 165 Options Style: B Sleeve: Type: Integral sleeve; Length (in): 12; Gauge: 20; Clearance (in): 4.25Transition: Front: Type: Round; Ship: Mounted Transition: Rear: Type: Round; Ship: Mounted Angles: Type: Picture frame, 16 ga (2 sides) Ratings UL 555 fire resistance rating: 1-1/2 hour (vertical and horizontal) UL HNLJ.V-5: Ventilation Duct Assemblies Listings UL 555 listing: R11767 CSFM listing: 3225-0368:101 Model VFD-10-B with integral sleeve Round transition Details Line Item Tag Qty Duct(in.xxxx) Sections Damper assembly(in.xxxx) W x H D Wide x High W x T (in) 4 Rm 122A 2 6 x 6 6 1 x 1 6 x 8 Notes: Dwg M-101 PPOTTORFF®5101 Blue Mound Road, Fort Worth, Texas 76106 www.pottorff.com Information is subject to change without notice or obligation.NOTE:Dimensions in parentheses ( ) are millimeters.Design I503 Fire and Fire-Smoke Dampers Installation Instructions M-54610May 2016Design I503 Installation Instructions horizontal mount dampers in non-concrete barrier CFS, VFD, FD, FSD series fire and fire-smoke dampers Figure 1 General The following supplement provides basic assembly installation instruc- tions for the 11/2 hour rated fire dampers, combination fire smoke dampers and CFS Series ceiling fire smoke dampers when mounted horizontally in UL Design I503. UL Design I503 is a 2 hour fire rated horizontal barrier made from steel studs and gypsum board. Load is limited to the dead weight of the assembly. Installation applies for horizontal mount dampers up to maximum size 48"x 48"(1219 x 1219). Single section size for each model may be different and is limited to the maximum size in the product specifications. Clearance To make installation of the damper assembly into the floor opening easier, clearance between the damper sleeve and floor opening is recommended. However there is no minimum clearance requirement between the floor opening and damper sleeve. Installation Guidelines Pottorff dampers are designed to be trouble and hassle free under normal operation. The intent of a proper installation is to secure the damper assembly into the opening in such a manner as to prevent distortion and disruption of damper operation. The following items will aid in completing the damper installation: A. Retaining angles 20 gauge (1) minimum must be used to install the damper assembly into the floor opening. The leg of the retaining angle on the damper sleeve shall be a minimum 11/4" (32) and the leg of the retaining angle on the floor shall be long enough to overlap the floor by 1" (25) minimum and cover the clearance space between sleeve and floor opening. Damper Sleeve Retaining Angle 5/8" (16) Gypsum Board 2 Layers Steel Joist (back to back) Steel Channel 5/8" (16) Gypsum Board 2 Layers 5/8" (16) Gypsum Board 1 Layer Figure 2 Warning Read the installation instructions thoroughly before installing or servicing this equipment. Improper installation, adjustment, service or maintenance can cause property damage or injury. B. Retaining angles shall be attached to the sleeve using one of the following connections: 1. tack or spot welds 2. 3/16" (4.8) diameter steel rivets 3. #10 sheet metal screws 4. 1/4" (6)nuts and bolts Two connections minimum are required and shall be at a maximum 2" (51) from the corners and at maximum 6" (152)on center. C. Retaining angles shall be attached to the floor on each side with minimum 2 self-drilling Type S #10 steel screws 17/8" (48)long, spaced 8" (203) maximum on center and maximum 6"(152) from the corners. D. Retaining angles are required to be installed above the floor and are optional below the floor. PPOTTORFF®5101 Blue Mound Road, Fort Worth, Texas 76106 www.pottorff.com Information is subject to change without notice or obligation.NOTE:Dimensions in parentheses ( ) are millimeters.Design I503 Fire and Fire-Smoke Dampers Installation Instructions M-54610May 2016Design I503 Installation Instructions horizontal mount dampers in non-concrete barrier CFS, VFD, FD, FSD series fire and fire-smoke dampers UL Design I503 Framing 8 ft (2.4) MaximumH W 16" (406) oc Maximum 16" (406) oc Maximum 12" (305) Minimum Back to back steel joists Steel channel overlapping the joist Steel channel Figure 3 A. On the sides parallel to the steel joists, the damper shall be framed by 2 steel joists installed back to back with a steel channel overlapping the joist facing the damper sleeve. See Fig. 3. B. On the side perpendicular to the steel joists, the damper shall be framed by steel channel as specified in the UL Design I503. C. The opening shall be lined with 5/8" (16) USG Type C gypsum board that is screwed to the steel joist and steel channel with Type S steel screws minimum 17/8" (48) long spaced at 12" (305)maximum on center. *The opening for the damper shall be large enough to account for the opening to be lined with 5/8" (16)gypsum board, plus the clearance needed to install the dampers. POTTORFF®5101 Blue Mound Road, Fort Worth, Texas 76106 www.pottorff.com Information is subject to change without notice or obligation.NOTE:Dimensions in parentheses ( ) are millimeters.Fire Dampers IIFDO&M(1/1) May 2008fire damperoperation and maintenance instructions Dampers do not typically require maintenance provided they are kept clean and dry. All moving parts are self-lubricating and additional lubrication is not required. If additional lubrication of multi-blade damper axle bearings, jackshaft bearings or jamb seals is desired, use a silicone or dry graphic lubricant. Do not use petroleum-based lubricants or other lubricants that attract contaminants and collect dust. Regular inspection and maintenance is essential to ensure that life-safety systems will perform as intended during emergencies. Dampers shall be cycled and tested in accordance with NFPA 90 recommendations and local codes. Maintenance Simulated Fire Closure • Non-Spring Assisted DampersOperate the damper by removing the fusible link (or by ‘melting’ the fusible link with a heat source) and allowing the blades to drop or close naturally. CAUTION - Avoid injury - keep clear of blade travel path.Lift the blade package to the top of the damper to reopen and replace the fusible link. Take care not to rack, deform or damage the blades while reopening. • Dynamic Rated OR Spring Assisted DampersDue to spring assisted closure force, removing the fusible link is NOT recommended as a means of closure testing. Instead, when testing is required, ‘melt’ the fusible link with an appropriate heat source and allow the blades to close automatically. CAUTION - Avoid injury - Keep clear of blade travel path.Lift the blade package to the top of the damper to reopen and replace the fusible link. Take care not to rack, deform or damage the blades when reopening. Reopening Spring Assisted OR Dynamic Rated Fire Dampers may be very difficult and in some cases impossible.If the damper is deemed impossible or impractical to test or reopen, then a thorough examination of the blade travel path is required to insure that nothing will prevent the damper from closing. Common obstructions include: retaining angle installation screws, racked damper frames, construction debris and contaminants. CAUTION - Testing Spring Assisted OR Dynamic Rated Fire Dampers under airflow conditions is not recommended and may severely damage or destroy duct work. Operational Testing Troubleshooting Guide Problem Damper does not open and/or close fully Fusible link is separated Installation screws interfering with damper blade or linkage travel Frame is ‘racked’ causing blades to bind Contaminants on damper Excessive heat Replace link. Note:If the damper is installed near a heat source (heat exchanger, burner, furnace, etc.) higher temperature links may be required to prevent unwanted closure. Inspect and remove interfering screws or debris Adjust frame to be square and plumb Clean with compressed air, mild detergent or mild non-petroleum based solvent Possible Cause Solution 2-1/2" (63) Min. Studor Runner 1” (25) Min. 1/2" (13) Min.Gypsum Wallboard Angle Fastener (See Note 2) Retaining Angle DamperSleeve 2-1/2" (63) Min. Studor Runner 1/2" (13) Min. Gypsum Wallboard Angle Fastener(See Note 2) Retaining Angle DamperSleeve NOTES 1. Gypsum panels must be screwed 12" (305)O.C. maximum to all stud and runner flanges surrounding opening. 2. Mounting angles shall be a minimum of 3/4" x 1-1/2" tall x 20 gauge (19 x 38 x 1.0).For opening sizes ≤ 80" wide (2032), 96" high (2438), and not exceeding 26.67 square feet in area retaining angles are only required on one side of the partition and must be attached to the sleeve and the partition. For larger openings (or optional on smaller openings), 1-1/2" x 1-1/2" x 16 gauge (38 x 38 x 1.5). retaining angles are required on both sides of the partition and must be attached to the sleeve. Attachment to the sleeve shall be with No. 10 (M5) screws or bolts, 3/16" (4.8)diameter steel rivets, Quick-Lock joints or welds, at 12" (305) o.c. maximum. Attachment to partition/opening shall be with min. #10 fasteners with a minimum length as follows: For metal stud and the angles under the drywall, the fasteners must be a min. 1/2" long. For metal stud and the angles over the drywall the fastener must be a min. 1/2" longer than the thickness of the drywall. i.e. if the partition has one layer of 5/8" drywall on the attachment side, the screws must be 1/2" + 5/8" = 1-3/8" long. The fasteners in the partition should be located such that they are 1/2" below the top of the 1-1/2" flange of the retaining angles. Fasteners in the partition should be spaced 12" o.c. max. A minimum of two connections per side, top and bottom. A minimum 3/4" x 20 gauge (19 x 1)flange termination may be used in lieu of mounting angles. Refer to Sleeve Termination Supplemental Installation Instructions and Framing for Fire Dampers for further details. Ensure that attachment device does not interfere with the operation of the damper and the free movement of the damper blades. 3. All fasteners to be per UL Classified wall design. 4. See standard damper installation instruction sheets for additionaldetails. 5. For dampers larger then 120" x 80" (3048 x 2032) double vertical studs are required. Opening Preparation Detail LIS T IN G S ER V I C ESTATEOFCALIFOR NI AS TATEFIREMARSHA LLDouble Stud Not Required On Penetrations 36” x 36” (915 x 915) Or Smaller 2”(51) Floor Runner Two Fasteners (See Note 3) 24”(610) O.C. Maximum 3” (76) Minimum Two Fasteners (See Note 3) 24” O.C.(610)Maximum 24” O.C.(610)Maximum 2”(51) Ceiling Runner TESTED PER U.L. 555 SEE DETAILS ON UL CLASSIFICATION MARKING ON ENCLOSED PROD UCT® UL CLASSIFIED ® UL CLASSIFIED c 2-1/2” (63) Min. Runner Screws 2-1/2” (63) Min. Stud Section A-A Wall with Single Layer of Drywall Damper Sleeve 2-1/2" (63) Min. Studor Runner 1/2" (13) Min.Gypsum Wallboard AngleFastener(See Note 2) RetainingAngle Damper Sleeve 2-1/2" (63) Min. Studor Runner 1” (25) Min. 1/2" (13) Min. Gypsum Wallboard AngleFastener(See Note 2) RetainingAngle Wall with Two Layers of Drywall For Openings ≤ or80” x48”(2032x1218) 40”x96”(1016x2438) Note:Full length studs are not required next to the damper if the spacing from the damper to the full length stud does not exceed the maximum stud spacing. The open- ing may be framed with studs that are attached to full length studs."A" "A" 80” x 48”(2032x1218) 40”x 96”(1016x2438) For Openings ≤ or POTTORFF®5101 Blue Mound Road, Fort Worth, Texas 76106 www.pottorff.com Information is subject to change without notice or obligation.NOTE:Dimensions in parentheses ( ) are millimeters.Fire and Fire Smoke Dampers IIMSAugust 2013metal stud framing in drywall partitions 11/2 hour — fire and combination fire smoke dampers installation instructions Double stud not required on Penetrations. 120" x 80" (3048 x 2032) or smaller Wall with Single Layer of Drywall Opening Preparation Detail Wall with Two Layers of DrywallNOTES 1. Gypsum panels must be screwed 12" (305)O.C. maximum to allstud and runner flanges surrounding opening. 2. Mounting angles shall be a minimum of 3/4" —1-1/2" tall —20 gauge (19—38 —1.0).For opening sizes ” 80" wide (2032), 96" high (2438), andnot exceeding 26.67 square feet in area retaining angles are onlyrequired on one side of the partition and must be attached to thesleeve and the partition. For larger openings (or optional on smalleropenings), 1-1/2" —1-1/2" —16 gauge (38 —38 —1.5).retaining angles arerequired on both sides of the partition and must be attached to thesleeve. Attachment to the sleeve shall be with No. 10 (M5)screws orbolts, 3/16" (4.8)diameter steel rivets, Quick-Lock joints or welds, at 12"(305)o.c. maximum. Attachment to partition/opening shall be with min.#10 fasteners with a minimum length as follows: For metal stud andthe angles under the drywall, the fasteners must be a min. 1/2" long.For metal stud and the angles over the drywall the fastener must bea min. 1/2" longer than the thickness of the drywall. i.e. if the partitionhas one layer of 5/8" drywall on the attachment side, the screws mustbe 1/2" + 5/8" = 1-3/8" long. The fasteners in the partition should be locat-ed such that they are 1/2" below the top of the 1-1/2" flange of theretaining angles. Fasteners in the partition should be spaced 12" o.c.max. A minimum of two connections per side, top and bottom. A mini-mum 3/4" —20 gauge (19 —1)flange termination may be used in lieu ofmounting angles. Refer to Sleeve Termination SupplementalInstallation Instructions and Framing for Fire Dampers for furtherdetails. Ensure that attachment device does not interfere with theoperation of the damper and the free movement of the damperblades. 3. See standard damper installation instruction sheets foradditionaldetails. C-H Stud OR I-Stud Angle Fastener (see note 2) Retaining Angle Damper Sleeve J-Runner C-H Stud OR I-Stud Angle Fastener (see note 2) Retaining Angle Damper Sleeve J-Runner LIS T IN G SER V I C EST ATE OF CALIFOR NIA ST ATEFIREMARS H ALLTESTED PER U.L. 555 SEE DETAILS ON UL CLASSIFICATION MARKING ON ENCLOSED PRODUCT® UL CLASSIFIED ® UL CLASSIFIED c J-RUNNER 1-1/2” x 1-1/2” x 2”(38 x 38 x 51) Min.Angle Screw Attached with5/8” (16) Type S-12 (Min.) Screw 24” O.C. (610) MAXIMUM FASTEN J-TRACK IN THIS MANNER I-STUD A CUT HERE AND BEND DOWN B J-TRACK FOLDED AS SHOWN TO SLIP INTO VOID ATTACH TO J-TRACK HEADER I-STUDS J-TRACK HEADERS WITH ENDSSLOTTED TO FITINTO I-STUDS A B 24” (610) 24” (610) 24” (610) 24” (610) Optional Opening Preparation Detail for I-Stud Assembly POTTORFF®5101 Blue Mound Road, Fort Worth, Texas 76106 www.pottorff.com Information is subject to change without notice or obligation.NOTE:Dimensions in parentheses ( ) are millimeters.Fire and Fire Smoke Dampers IIMSCSJuly 2008metal stud framing in cavity shaftwall partitions11/2 hour — fire and combination fire smoke dampersinstallation instructions All Pottorff 1-1/2 (38)hour fire and fire-smoke dampers may use single-side mounting angles in lieu of conventional 2-sided mounting angles. Single- side mounting angles may be field fabricated or factory-supplied and may be installed in metal stud, wood stud, concrete or masonry partitions. Maximum Size LIS T IN G SER V I C ESTATEOFCALIFORNIASTATEFIREMARSHALLTESTED PER U.L. 555 AND 555S SEE DETAILS ON UL CLASSIFICATION MARKING ON ENCLOSED PROD UCT c Application Vertical:80" wide x 96" high (2032 x 2438), and not exceeding 26.67 square feet in area. Horizontal:144" wide x 96" high (3658 x 2438). Note:Size shall not exceed damper model size limits. General Notes A.Install dampers in accordance with the appropriate damper installation instructions sheet. Replace conventional 2-side mounting angles with single-sided mounting angles as appropriate. B. Vertical:Single-side mounting angles shall be a minimum of 3/4" x 1- 1/2" tall x 20 gauge (19x38x1.0)steel. For metal stud partitions only, the single-side mounting angles may be attached to the metal stud prior to installation of the drywall. See Figure 3. Horizontal:Single-side mounting angles shall be a minimum of 1-1/2" x 1-1/2" tall x 16 gauge (38x38x1.5)steel. C.Attach single-side mounting angles to the damper sleeve and the partition with a minimum of: No.10 (M5)steel screws or bolts, 3/16" (4.8)diameter steel rivets, Quick-lock joints or welds. For concrete or masonry partitions attach the angles with a minimum of No. 10 (M5)steel fasteners: anchors, bolts or self-tapping masonry screws. There must be a minimum of two connections per side, on all four sides. Ensure that the attachment device does not interfere with the operation of the damper and the free movement of the damper blades. Vertical: Attach mounting angles to the sleeve and the partition at 12" (305) o.c. maximum. Horizontal: Attach mounting angles to the sleeve at 6" (152) o.c. maximum, and to the partition at 24" (610) o.c. maximum. Figure 2:Metal Stud Figure 3:Under Drywall Installation (Metal Stud Only) Figure 4:Wood Stud Figure 5:Concrete or Masonry Figure 6:Horizontal Installation Concrete or Masonry only Note: The annular space between damper sleeve and wall opening must not be filled with firestop materials such as fill, void, or cavity materials. However, if optional sealing between the mounting angle (or flange) leg and the surface of the partition, wall, or floor and/or between the mounting angle leg and the surface of the damper sleeve is required, any of the following sealants may be used: Dow Corning 700 or 732 or DOWSIL 700 or 732 or GE RTV 108 or SCS 1201 RTV. These sealants must be applied such that they do not intrude into the annular space between the outside surface of the damper sleeve and the opening of the partition, wall or floor into which the damper/sleeve is being installed. C A A A B C B C C C A A B B Single Mounting Angle Over Drywall Single Mounting Angle UNDER Drywall * Metal Stud Only B Metal Stud Damper Sleeve B Metal Stud Damper Sleeve Figure 1:Single Mounting Angle Over Drywall with Wood Stud (Cutaway shown for illustration purposes only) A POTTORFF ®5101 Blue Mound Road, Fort Worth, Texas 76106 www.pottorff.com Information is subject to change without notice or obligation.NOTE:Dimensions in parentheses ( ) are millimeters.Fire and Fire Smoke Dampers IISSMAAugust 2019single-side mounting angles 11/2 hour — fire and combination fire smoke damper installation instructions Underwriter’s Laboratories file #R11767 and R15401. The product is also listed by CSFM fire #3225-0368:101, #3225-0368:110 and conforms to NFPA 90A and NFPA 92A. B (c) Flat Drive Slips - Breakaway Connections Joints using connectors of the types shown in 1) above on the top and the bot tom and using flat drive slips not exceeding 20" (508) duct height on the sides (see sketch above). Note: If optional seal- ing of these joints is required, the following sealants may be applied in accordance with the instructions supplied by the manu- facturer of the sealant: Design Polymerics - DP 1010 or Precision – PA2084T. DAMPER/SLEEVE ASSEMBLIES WITH COL LARS FOR ROUND AND FLAT OVAL DUCTS Cleat Duct End Flange Sleeve FlangeSystem Connection Fire Damper Duct Plastic or steel cleat12" (305) c-c(min. 1 per side) Angle Neoprene orDuctmate 440Gasket (d) TDC and TDF roll-formed 4-bolt flanged connections assembled per the manufacturer’s instructions using gaskets and metal or plastic cleats.Flanges may be joined with or without four 3/8" (10) steel bolts and nuts. (e) Ductmate, Ward, Nexus, MEZ slip on 4-bolt flanged con nec tions assembled per the manufacturer’s instructions using gas kets and metal or plastic cleats as shown above. As an option, a 3/8" (9)bolt may be used in the corners to help with the alignment. [Min. 20 ga (1.0)thick sleeve]. Note:Cleats may be replaced by #10 x 3/4" (19)Tek Screws. • See Table below. 1-1/4"(32)Min. 1/4"(6)Max. Flange Sleeve3/4" (19) Grille Duct-sleeve connections listed in UL 555,"Standard For Fire Damp ers".1) Additional duct-sleeve connections which were tested and witnessed by UL. The con nec tions per formed within the requirements of the UL test cri te ria. (a) Rectangular Duct - Breakaway Con nec tions Joints using connections shown in 1) above with a max i mum of two No.10 (M5) sheet metal screws on each side and on the bot tom located in the center of the slip pock et and pen e trat ing both sides of the slip pocket. Note: UL tested duct seal ant may be used. 2) Duct End Flange CornerPiece Gasket For flat oval ducts, the diameter shall be con sid ered the largest (ma jor) di men sion of the duct. UL tested duct sealant may be used. (1) Notes: FLANGED DUCT CON NEC TIONS FLANGE TERMINATION AT A GRILLE Grille (by others). All of these connections may be used to terminate the damper sleeve in place of slip joints, for Pottorff mul ti ple blade or single blade fire dampers, cur tain type fire damp ers, and com bi na tion fire-smoke damp ers. Grille is to be screwed to minimum 3/4" x 20 gauge (19 x 1)flange. Application - UL Approved Breakaway Connections Select the damper with sleeve of suf fi cient length to permit attachment, with pe rim e ter mouting angles, to duct work on one side of the wall, floor or ceiling opening. Detail shown is for vertical ap pli ca tion. Grille flange must be minimum 1- 1/4" (32)and overlap the opening a minimum of 1/2" (13). PLAIN "S" SLIP HEMMED "S" SLIP DOUBLE "S" SLIP INSIDE SLIP JOINT STANDING S STAND ING S (ALT.)STANDING S (BAR RE IN FORCED) STANDING S (ANGLE REINFORCED) General Installation for Flanged Duct Breakaway Con nec tions Flange corner pieces insert into the hol low web of the an gles and slip over the duct and sleeve. Closed cell neo prene gas ket or Ductmate 440 gasket tape is then applied to one face of the flange. To complete installation, butt the flange fac es to geth er, align ing edges, and in stall cleats over the flange. Cleats shall be 6" (153)long,plastic or steel. Install min i mum one per side, spaced 12" (305)center to center. Note:Cleats may be replaced by #10 x 3/4" (19)Tek Screws. • See Table below. (2) POTTORFF ®5101 Blue Mound Road, Fort Worth, Texas 76106 www.pottorff.com Information is subject to change without notice or obligation.NOTE:Dimensions in parentheses ( ) are millimeters.Fire and Fire Smoke Dampers IISTJune 2012sleeve terminations installation instructions Sleeve Width (w) or Height (h) Tek Screw Table w or h < 24" 24" ≤ w or h < 36" 36" ≤ w or h < 54" 54" ≤ w or h < 72” w or h ≥ 72" 1 per side 2 per side 3 per side 4 per side 5 per side No. of Tek Screws (b) Round Duct - Breakaway Connections Joints where round or oval spiral ducts attach to round or oval collars which are part of the damper sleeve as shown below. No.10 (M5) sheet metal screws are spaced equal ly around the cir cum fer ence of the duct per the following: • Duct diameters 22" (560)and smaller—3 screws. • Duct diameters over 22" (560) to and including 36" (920)—5 screws. Note: It is not necessary to have the same connections on the damper sleeve and on the duct being connected/attached to the damper sleeve. The TDC, TDF, Ductmate, Ward, Nexus and MEZ can be installed and mixed on the sleeve/duct. i.e. the damper sleeve can have a Ductmate connection and can be attached to duct wth a TDC, TDF, etc. type connection, or vice versa. Any of the previous- ly mentioned connections can be mixed/matched on the damper sleeve and duct.LIS T IN G S ERV I C ESTATEOFCALIFORNIA STATEFIREMARSHAL LSEE DETAILS ON UL CLASSIFICATION MARKING ON ENCLOSED PROD UCT c A. Concrete or masonry fire partition shown. The opening shall be a minimum or equal to 1/4" (6)with a maximum of 3/4" (19)larger than the overall damper and sleeve assembly size. When openings are larger than 3/4" (19), but less than or equal to 6" (152)the mounting angles must be a minimum of 16 gauge (1.5)and must be wide enough to overlap the opening by a minimum of 1" (25). Damper must be installed with leading edge of closed blade within the partition. B. For rigid type duct connections, the sleeve shall be a minimum of 16 gauge (1.5)for dampers up to 36" wide by 24" high (914 x 610)and a minimum of 14 gauge (1.9)for larger units. When lighter gauge sleeves are used, one or more of commonly used break away style connections are required. Refer to Sleeve Termination Supplemental Installation Instructions for further details. In no case will the sleeve gauge be less than the duct gauge to which it is connected. Damper sleeve shall not extend more than 6" (152)beyond the rated partition unless an access door or Smoke Detector is installed in the sleeve which then permits the extension to be a maximum of 16" (406). C. Mounting angles shall be a minimum 1-1/2" x 1-1/2" x 16 gauge (38 x 38 x 1.5).Mounting angles are only required on the top side of the opening and must be attached to the sleeve at 6" (152)o.c. maximum, to the partition at 24" (610)o.c. maximum, with a minimum of two fasteners per side to both the sleeve and partition on all four sides. Alternately, mounting angles may be installed on both sides of the partition and must be attached only to the sleeve at 12" (305)o.c. maximum, with a minimum of two connections per side on all four sides. Attachment to the sleeve shall be a minimum of No. 10 (M5) steel fasteners: anchors, bolts, or self-tapping masonry screws. A minimum 3/4" x 20 gauge (19 x 1)flange termination may be used in lieu of mounting angles. Ensure that the attachment device does not interfere with the operation of the damper and the free movement of the damper blades. Note:If optional sealing between the mounting angle (or flange) leg and the surface of the partition, or floor, and/or between the mounting angle leg and the surface of the damper sleeve is required, the following sealants may be used: Dow Corning 732 or DOWSIL 732 or GE RTV 108 or SCS 1201 RTV. These sealants should be applied such that they do not intrude into the annular space between the outside surface of the damper sleeve and the opening of the partition, or floor, into which the damper sleeve is being installed. Annular space between damper sleeve and opening shall not be filled with firestop materials such as fill, void, or cavity materials. D. When joining multiple sections or fastening the damper to the sleeve, the damper shall be fastened with 3/16" (4.8)diameter steel rivets, Quick-Lock Joints, welds, No. 10 (M5)bolts or sheet metal screws at 8" (203)o.c. maximum. A minimum of two connections per side, top and bottom.LIS T IN G SERV I C ESTATEOFCALIFORNIA STATEFIREMARSHALL Underwriter’s Laboratories file #R11767. The product is also listed by CSFM File # 3225-0368:101. Individually sleeved dampers can be installed in partitions wider than the maximum U.L. multiple section size using the Support Mullion for Oversized Floor Openings. See Support Mullion for Oversized Floor Openings Installation Instructions for further details. DUCT SIZ ES STAINLESS STEEL 40" x 40" (1016 x 1016) 80" x 40" or 40" x 80" (2032 x 1016) (1016 x 2032) Model VFD-10 40" x 40" (1016 x 1016) 80" x 80" (2032 x 2032) GALVANIZED STEEL Model VFD-10 VFD-10D 36" x 36" (914 x 914) 36" x 36" or 72" x 18" (914 x 914) (1829 x 457) POTTORFF®5101 Blue Mound Road, Fort Worth, Texas 76106 www.pottorff.com Information is subject to change without notice or obligation.NOTE:Dimensions in parentheses ( ) are millimeters.Fire Dampers IIVFD10HORAugust 2019The following installation details apply to models VFD-10D and VFD-10 horizontal 11/2 hour — fire dampers installation instructions Maximum Single Section Maximum Multiple Section C A C B D A C B D Style - A, AR & AO Style - B, BR & BO Style - C, CR & CO C A C B D Duct Connections Damper Installation (2-sided Mounting Angle) Damper Installation For Typical Flange Termination with Grille / Reg is ter Single Side Mounting Angle Damper Installation SEE DETAILS ON UL CLASSIFICATION MARKING ON ENCLOSED PROD UCT® UL CLASSIFIED ® UL CLASSIFIED Style - A, AR & AOStyle - B, BR & BOStyle - C, CR & COC A C B DDuct ConnectionsDamper Installation For Typical Fire Rated Partition Damper Installation For Typical Flange Termination with Grille / Reg is ter A. Concrete or masonry fire partition shown. See Wood Stud and/or Steel Stud Framing for Fire Dampers In Drywall and/or Cavity Shaftwall Partitions Supplemental Installation Instructions for further vertical installation details. The opening shall be a minimum of 1/4" (6)with a maximum of 3/4"(19)larger than the overall damper and sleeve assembly size. When openings are larger than 3/4" (19), but less than 6" (152)the mounting angles must be a min- imum of 16 gauge (1.5)and must be tall enough to overlap the opening by a minimum of 1" (25). Damper must be installed with leading edge of closed blade within the partition. B. For rigid type duct connections, the sleeve shall be a minimum of 16 gauge (1.5)for dampers up to 36" wide by 24" high (914 610)and 14 gauge (1.9) for larger units. When lighter gauge sleeves are used, one or more of commonly used breakaway style connections are required. Refer to Sleeve Termination Supplemental Installation Instructions for further details. In no case will the sleeve gauge be less than the duct gauge to which it is con- nected. Damper sleeve shall not extend more than 6" (152)beyond the rated partition unless an access door or Smoke Detector is installed in the sleeve which then permits the extension to be a maximum of 16" (406). C. Mounting angles shall be a minimum of 3/4" 1-1/2" tall 20 gauge (19 38 1.0). For opening sizes ≤ 80" wide (2032), 96" high (2438), and not exceeding 26.67 square feet in area retaining angles are only required on one side of the partition and must be attached to the sleeve and the partition. For larger openings (or optional on smaller openings), 1-1/2" 1-1/2" 16 gauge (38 38 1.5). retaining angles are required on both sides of the partition and must be attached to the sleeve. Attachment to the sleeve shall be with No. 10 (M5)screws or bolts, 3/16" (4.8)diameter steel rivets, Quick-Lock joints or welds, at 12" (305) o.c. maximum. Attachment to partition/opening shall be with min. No. 10 fasteners with a minimum length as follows: For metal stud and the angles under the drywall, the fasteners must be a min. 1/2" long. For metal stud and the angles over the drywall the fastener must be a min. 1/2" longer than the thickness of the drywall. i.e. if the partition has one layer of 5/8" drywall on the attachment side, the screws must be 1/2" + 5/8" = 1-3/8" long. For wood stud openings, the min. length is 1-1/2" longer than the thickness of drywall on the attachment side. For concrete or masonry openings, the anchors must be for min. No. 10 fasteners- screws or bolts. In lieu of masonry anchors and bolts/screws, self-tapping masonry screws can be used. The fasteners in the partition should be located such that they are 1/2" below the top of the 1-1/2" flange of the retaining angles. Fasteners in the partition should be spaced 12" o.c. max. A minimum of two connections per side, top and bottom. A minimum 3/4" 20 gauge (19 1)flange termination may be used in lieu of mounting angles. Refer to Sleeve Termination Supplemental Installation Instructions and Framing for Fire Dampers for further details. Ensure that attachment device does not interfere with the operation of the damper and the free movement of the damper blades. Note: If optional seal- ing between the retaining angle (or flange) leg and the surface of the partition, wall, or floor, and/or between the retaining angle leg and the surface of the damper sleeve is required, the following sealants may be used: Dow Corning 732 or DOWSIL 732 or GE RTV 108 or SCS 1201 RTV. These sealants should be applied such that they do not intrude into the annular space between the outside surface of the damper sleeve and the opening of the partition, wall, or floor, into which the damper/sleeve is being installed.LIS T IN G S ER V I C ESTAT E OFCALIFORNIA S TATEFIREMARS H ALLSEE DETAILS ON UL CLASSIFICATION MARKING ON ENCLOSED PROD UCT® UL CLASSIFIED ® UL CLASSIFIED Product Listing Underwriter’s Laboratories file #R11767 and CSFM File # 3225-0368:101 DUCT SIZ ES GALVANIZED STEEL Model VFD-10 *36" 48" (914 1219) *120" 72" or 72" 120" (3048 2032)(2032 3048) 6" 6" (152 152) 36" 48" (914 1219) 36" 72" or 72" 36" (915 1829)(1829 915) 4" 4" (102 102) 40" 40" (1016 1016) 80" 40" or 40" 80" (2032 1016)(1016 2032) 108" 24" (2743 610) 4" 4" (102 102) Model VFD-10D Model VFD-10-TL A C B D Note: Annular space between damper sleeve and wall opening shall not be filled with firestop materials such as fill, void or cavity materials. *Maximum single section is 36" 36" (914 914) for multiple sections larger than 36" 96" (914 2438)or 72" 48" (1829 1219) GALVANIZED STEEL 48" 48" (1219 1219) 120" 80" or 80" 120" (3048 2032)(2032 3048) 4" 4" (102 102) STAINLESS STEEL POTTORFF ®5101 Blue Mound Road, Fort Worth, Texas 76106 www.pottorff.com Information is subject to change without notice or obligation.NOTE:Dimensions in parentheses ( ) are millimeters.Fire Dampers IIVFD10VERT1 M-54492August 2019The following installation details apply to models VFD-10, VFD-10D, VFD-10TL and VFD-10D-TL vertical 11/2 hour — fire dampers installation instructions Maximum Single Section Maximum MultipleSection Minimum STAINLESS STEEL 36" 36" (914 914) NA 6" 6" (152 152) Model VFD-10D-TL 36" 48" (914 1219) 36" 72" or 72" 36" (915 1829)(1829 915) 6" 6" (152 152) GALVANIZED STEEL GALVANIZED STEEL The following installation details apply to models VFD-10, VFD-10D, VFD-10TL and VFD-10D-TL vertical 11/2 hour — fire dampers installation instructions POTTORFF®5101 Blue Mound Road, Fort Worth, Texas 76106 www.pottorff.com Information is subject to change without notice or obligation.NOTE:Dimensions in parentheses ( ) are millimeters.Fire Dampers IIVFD10VERT2 M-54492 August 2019D. When joining multiple sections or fastening the dampers to the sleeve, the damper shall be fastened with 3/16" (4.8) diameter steel rivets, Quick-Lock joints, welds or No. 10 (M5)bolts or sheet metal screws at 8" (203) o.c. maximum if multiple sections assemblies are smaller than 36” 96” (914 x 2438) and 72" 48" (1829 1219)or 6" (152)o.c. maximum for multiple sections larger than 36" 96" (914 x 2438)and 72" 48" (1829 x 1219). There must be a minimum of two connections per side, top and bottom. On multiple sections larger than 36" 96" (914 2438)and 72" 48" (1829 1219)the maximum single section size shall be 36" 36" (914 914). For assemblies multiple sections wide and multiple sections high a minimum 14 gauge 5" (127)wide supplemental steel mullion plate is required. The mullion plate length should be either full length or full height of the multiple sections assembly. The mullion plate must be installed between adjacent damper frames running parallel to the sleeve/duct width/height. Mullions are not required for dampers assemblies that are single sections wide and multiple high or single sections high and multiple wide. The support mullion must be attached to the damper frames using welds or No. 10 (M5)bolts, sheet metal screws or minimum 3/16" (4.8) diameter steel rivets at 6" (152)o.c. maximum and 1" maximum from the frame corner. #10 Screw Installed 6" O.C. Max Screw Installed 1" Max from corner Horizontal Mullion Two Fasteners (See Note 3)Ceiling Runner Double Stud Not Required On Penetrations x (915 x 915) Or Smaller (51) (51) O.C.(610)Maximum O.C.(610)Maximum Floor Runner Two Fasteners (See Note 3) (76) Minimum (610) O.C. Maximum Wall with Two Layers of Drywall Opening Preparation Detail Wall with Single Layer of Drywall NOTES 1. Gypsum panels must be fastened 12" (305)O.C. maximum to all stud andrunner flanges surrounding opening. 2. Mounting angles shall be a minimum of 3/4" x 1-1/2" tall x 20 gauge (19 x38 x 1.0). For opening sizes ” 80" wide (2032), 96" high (2438), and notexceeding 26.67 square feet in area retaining angles are only requiredon one side of the partition and must be attached to the sleeve and thepartition. For larger openings (or optional on smaller openings), 1-1/2" x 1-1/2" x 16 gauge (38 x 38 x 1.5). retaining angles are required on both sidesof the partition and must be attached to the sleeve. Attachment to thesleeve shall be with No. 10 (M5)screws or bolts, 3/16" (4.8)diametersteel rivets, Quick-Lock joints or welds, at 12" (305)o.c. maximum.Attachment to partition/opening shall be with min. #10 fasteners with aminimum length as follows: For wood stud openings, the min. length is1-1/2" longer than the thickness of drywall on the attachment side. Thefasteners in the partition should be located such that they are 1/2" belowthe top of the 1-1/2" flange of the retaining angles. Fasteners in the parti-tion should be spaced 12" o.c. max. A minimum of two connections perside, top and bottom. A minimum 3/4" x 20 gauge (19 x 1)flange termina-tion may be used in lieu of mounting angles. Refer to SleeveTermination Supplemental Installation Instructions and Framing for FireDampers for further details. Ensure that attachment device does notinterfere with the operation of the damper and the free movement of thedamper blades. 3. All fasteners to be per U.L. Classified wall design. 4. See standard damper installation instruction sheets for additional details.LIS T IN G S ER V I C ESTATEOFCALIFOR NI AS TATEFIREMARSHA LLTESTED PER U.L. 555 SEE DETAILS ON UL CLASSIFICATION MARKING ON ENCLOSED PRODUCT® UL CLASSIFIED ® UL CLASSIFIED c DamperSleeve 2-1/2" (63) Min. Studor Runner Angle Fastener(See Note 2) Retaining Angle Damper Sleeve 2-1/2" (63) Min. Studor Runner 1” (25) Min. Angle Fastener(See Note 2) Retaining Angle 2-1/2" (63) Min. Studor Runner 1” (25) Min. Angle Fastener (See Note 2) Retaining Angle Damper Sleeve 2-1/2" (63) Min. Studor Runner AngleFastener(See Note 2) Retaining Angle DamperSleeve Two-Side System Two-Side System Single-Side System Note: Full length studs are not required next to the damper if the spacing from the damper to the full length stud does not exceed the maximum stud spacing. The opening may be framed with studs that are attached to full length studs. 3" 24" 24"24" 2" 2" 36" 36" For Openings ” or80” x 48”(2032x1218) 40”x 96”(1016x2438) Single-Side System For Openings ” or80” x48”(2032x1218) 40”x96”(1016x2438) POTTORFF ®5101 Blue Mound Road, Fort Worth, Texas 76106 www.pottorff.com Information is subject to change without notice or obligation.NOTE:Dimensions in parentheses ( ) are millimeters.Fire and Fire Smoke Dampers IIWFSDJuly 2008wood stud framing in drywall partitions11/2 hour — fire and combination fire smoke dampersinstallation instructions