Loading...
HomeMy WebLinkAbout233113 DUCT STANDARDS 037 - APPROVEDSUBMITTAL COVER SHEET JOB: ITHACA COLLEGE PHYSICIAN’S ASSISTANT ROTHSCHILD RENOVATION SUBMITTAL NUMBER: 37 DATE: 12 FEBRUARY 2021 SUBCONTRACTOR NAME: ARCHITECTURAL CONCRETE PLUS, LLC ARCHITECTURAL CONCRETE PLUS, LLC 69 HOLLISTER STREET DUNDEE, NY 14837 PHONE: 607-243-7113 FAX 315-423-0054 ACP PROJECT NO: 21-105 ARCHITECT: QPK 450 S SALINA ST STE 500, SYRACUSE, NY 13202 ARCHITECT PROJECT NO: 220157.00 (12/18/2020) TYPE OF SUBMITTAL: X PRODUCT DATA TEST REPORT SHOP DRAWING RECORD DOCUMENT SAMPLE CERTIFICATION MFGR COMPLIANCE CE CLOSEOUT DOCUMENT COLOR SELECTION MFGR DWG SUBSTITUTION MSDS SUBMITTAL DESCRIPTION DUCT STANDARDS SUPPLIER KIMBLE MANUFACTURER VARIOUS SPEC SECTION NUMBER & TITLE 233113 SUB-PARAGRAPH DRAWING NO 1ST TIME SUBMISSION X REVISION PRIME CONTRACTOR’S STAMP/CERTIFICATION : I HEREBY CERTIFY THAT I HAVE REVIEWED THIS SUBMITTAL, VERIFIED THE PRODUCTS, VERIFIED FIELD MEASUREMENTS WHERE APPROPRIATE AND HAVE COORDINATED THE INFORMATION WITHIN THE SUBMITTAL WITH THE REQUIREMENTS OF CONTRACT DOCUMENTS. THE SUBMITTED ITEMS COMPLY IN EVERY RESPECT WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS AND SPECIFICATIONS ARCHITECT/ENGINEER REVIEW STAMP: PRIME CONTRACTOR/CONTRACT/BID PKG NO. SIGNED: POSITION: DATE: COMMENTS: 5HFHLYHG0&( X 2-16-21 SDM 0HFKDQLFDO&RQWUDFWLQJ([FHOOHQFH 6XEPLWWDO/RJ  6XEPLWWDO&RYHU6KHHW)RU   ,7+$&$&2//(*( 3$352*5$0 527+6&+,/'5(129$7,21 .LPEOH-RE&      'DWHRI6XEPLWWDO 1XPEHU2I &RSLHV  7KLV6XEPLWWDO3DJH  2I   68%  6SHF6HFWLRQ  'HVFULSWLRQ                         ,WLVWKHLQWHQWRI.LPEOH,QF7RSURYLGHHTXLSPHQWDQGPDWHULDOV WKDWPHHWVRUH[FHHGVWKHUHTXLUHPHQWVRIWKHFRQWUDFWGRFXPHQWV 7KLVVXEPLWWDOKDVEHHQ³UHYLHZHG´DQG³DSSURYHG´E\  *5(*),&$552 'DWH   H-6 2/11/21 233113 DUCT STANDARDS 2/11/21 SOUTHERNTIER CUSTOM FABRICATORS 1322 COLLEGE AVE ELMIRA N.Y.14901 LETTER OF TRANSMITTALL Phone (607) 732-0927 Fax (607) 734-0433 DATE:2/10/2021 JOB NO.21063-A TO:KIMBLE ATTENTION:CHAD MOSIER NAME OF PROJECT: ITHACA COLLEGE PHYSICIAN ASSISTANT PROGRAM SHOP STANDARDS FOR DUCT & ACCESORIES Type of Submittal:(Check) Is this a Resubmittal?Yes Shop Drawing Schedule Sample Product Data Certificate Color Sample Submittals Test Report Warranty Change Order Specifications Other: References: Spec. Section No. 233100 Drawing No(s) Paragraph: Rm or Det. No(s) Description: Product Name: Subcontractor: Manufacturer: Address: These are Transmitted as Checked Below: For Approval Approved as Submitted Resubmit Copies for Approval For Your Use Returned for Corrections Submit Copies for Distribution As Requested For Review & Comment Return Corrected Prints Approved as Noted Other Remarks: SHOP STANDARDS FOR DUCT & ACCESORIES Signed: ___________________________________________________________________________ Copy to : SENT BY: C. CARLTON 1322 College Avenue Elmira, New York 14901 (607) 732-0927 FAX (607) 734-0433 Duct Standards JOB NAME: ITHACA COLLEGE PHYSICIANS ASSISTANT PROGRAM JOB NUMBER: 21063-A DATE: 2/10/2021 ENGINEER: QPK DESIGN MECHANICAL CONTRACTOR: KIMBLE STCF SHOP STANDARDS FOR ITHACA COLLEGE TYPE OF DUCT PRESSURE CLASS W.G. SEAL CLASS LEAKAGE CLASS MATERIAL ACCOUSTIC LINER TABLE NOTES SUPPLY 2” A ADVISE Galvanized Y (1) RETURN 2” A ADVISE Galvanized Y (1) GENERAL EXHAUST 2” A ADVISE Galvanized N OUTSIDE AIR 2” A ADVISE Galvanized N TABLE NOTES: (1) DUCT LINER SHALL BE 1” UNLESS OTHERWISE INDICATED ON CONTRACT (2) (3) SPECIAL NOTES: (1)DUCT ROUTING SHALL BEST ATTEMPT TO ACCOUNT FOR 2” INSULATION WHERE APPLICABLE (2) (3) 5 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com – Product Specifications® (A) 3” 4” 5” 6” 7” 8” 9” 10” 12” 90o(R) 4.5” 6.0” 7.5” 9.0” 10.5” 12.0” 13.5” 15.0” 18.0” Dimensions Wt. Per 90o Elbow (DSE90) 0.8# 1.4# 1.8# 2.2# 3.5# 4.7# 6.1# 7.6# 10.2# Wt. Per 90o Elbow (NDSE90) N/A 1.4# 2.5# 3.4# 4.4# 5.4# 5.9# 6.4# 9.0# (A) 3” 4” 5” 6” 7” 8” 9” 10” 12” 45o(R) 4.5” 6.0” 7.5” 9.0” 10.5” 12.0” 13.5” 15.0” 18.0” Wt. Per 45o Elbow (DSE45) 0.6# 0.8# 1.0# 1.5# 1.8# 3.0# 3.5# 4.2# 6.5# Wt. Per 45o Elbow (NDSE45) N/A 0.8# 1.5# 2.0# 2.6# 3.2# 4.0# 4.8# 6.6# A = Diameter R = 1-1/2 A (centerline radius) S = 2” Flangeless elbows are continuously stitch welded on the throat and heel from end to end (past the bead). Welding Process Materials Available Key  Galvanized (3”- 4”), 24 ga.  Galvanized (5”- 12”), 22 ga.  Galvaneal [paint grip] (4”), 24 ga.  Galvaneal [paint grip] (5”- 12”), 22 ga.SARS A RS SS90o Die Stamped Flangeless Elbow Galvanized (DSE90) Galvaneal (NDSE90) 45o Die Stamped Flangeless Elbow Galvanized (DSE45) Galvaneal (NDSE45) – Product Specifications®6 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com A = Diameter R = 1A (centerline radius) S = 2” Flangeless elbows are continuously stitch welded on the throat and heel from end to end (past the bead). Materials Available Key  Galvanized (4”- 10”), 24 ga.  Galvanized (12”), 22 ga. 45o Die Stamped 1.0 CLR Flangeless Elbow (DSE145) 90o Die Stamped 1.0 CLR Flangeless Elbow (DSE190) (A) 4” 5” 6” 7” 8” 9” 10” 12” 90o(R) 4.0” 5.0” 6.0” 7.0” 8.0” 9.0” 10.0” 12.0” 45o (R) 4.0” 5.0” 6.0” 7.0” 8.0” 9.0” 10.0” 12.0” Dimensions Wt. Per90oElbow 0.8# 1.0# 1.4# 2.0# 2.4# 3.0# 3.8# 7.0# Wt. Per45oElbow 0.5# 0.6# 1.0# 1.2# 1.6# 2.0# 2.6# 4.0# S A RRRS SAR – Product Specifications®7 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com 90o Die Stamped 20 Gauge Flanged Elbow (DSEF90) 45o Die Stamped 20 Gauge Flanged Elbow (DSEF45)SARS A R(A) 3” 4” 5” 6” 7” 8” 9” 10” 11” 12” 14” 90o (R) 4.5” 6.0” 7.5” 9.0” 10.5” 12.0” 13.5” 15.0” 16.5” 18.0” 21.0” 45o (R) 4.5” 6.0” 7.5” 9.0” 10.5” 12.0” 13.5” 15.0” 16.5” 18.0” 21.0” Dimensions Wt. Per90oElbow(Alum.) 0.5# 0.7# 1.0# 1.7# 2.0# 2.8# 3.5# 4.0# 5.0# 6.2# N/A Wt. Per45oElbow 0.7# 1.0# 1.5# 2.0# 2.5# 3.2# 4.0# 5.0# 6.0# 7.0# 9.0# Wt. Per90oElbow 1.0# 1.5# 2.0# 3.5# 5.0# 5.7# 7.2# 8.5# 10.0# 13.0# 18.0# Wt. Per45oElbow(Alum.) 0.2# 0.5# 0.5# 1.0# 1.2# 1.5# 1.7# 2.2# 2.7# 3.2# 4.2# A = Diameter R = 1-1/2 A (centerline radius) S = 2”  Available assembled or unassembled Options Available Materials Available Key  Galvanized, 20 ga.  Stainless steel 304L & 316L, 20 ga.  Aluminum 3003, 20 ga.  PVS 4x4 mill, 20 ga. Galvanized and stainless steel are fully welded on the throat and heel by an automated welder. PVS and aluminum are assembled with rivets and sealed with silicone. Aluminum can also be fully tig welded on the throat and heel. Welding Process SSSS – Product Specifications®8 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com Gorelocked Elbows ASA SSS SSOptions Available  Specify CLR (1.5, 1.0, etc.)  Specify Degree (15o, 22.5o, 30o, 45o,  60o,90o, etc.)  Up to 30o = 2 Piece  30o+up to 60o = 3 Piece  60o+up to but not including 90o = 4 Piece  90o= 5 Piece Key A = Diameter S = 2” 45o 3-Piece 1.5 CLR Elbow (E45) 45o 3-Piece 1.0 CLR Elbow (E451) 90o 5-Piece 1.5 CLR Elbow (E90) 90o 5-Piece 1.0 CLR Elbow (E901)  Galvanized  Galvaneal  Stainless Steel 304 & 316  Aluminum Materials Available – Product Specifications®9 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com A B 1-Piece Spun Reducer – Short (4SPR) WeightEach 1.8# 1.8# 1.8# 1.8# 1.8# 2.1# 2.1# 2.1# 2.1# 2.1# 2.1# 2.2# 2.2# 2.2# 2.2# 2.2# 2.2# 2.4# 2.4# 2.4# 2.4# 2.4# 2.4# (B) 12” 12” 12” 12” 12” 14” 14” 14” 14” 14” 14” 15” 15” 15” 15” 15” 15” 16” 16” 16” 16” 16” 16” Dimensions (A) 6” 7” 8” 9” 10” 8” 9” 10” 11” 12” 13” 9” 10” 11” 12” 13” 14” 10” 11” 12” 13” 14” 15” WeightEach 0.6# 0.6# 0.6# 0.7# 0.7# 0.7# 0.8# 0.8# 0.8# 0.8# 1.1# 1.1# 1.1# 1.1# 1.2# 1.2# 1.2# 1.2# 1.3# 1.3# 1.3# 1.3# 1.3# 1.6# 1.6# 1.6# 1.6# (B) 4” 5” 5” 6” 6” 6” 7” 7” 7” 7” 8” 8” 8” 8” 9” 9” 9” 9” 10” 10” 10” 10” 10” 11” 11” 11” 11” Dimensions (A) 3” 3” 4” 3” 4” 5” 3” 4” 5” 6” 4” 5” 6” 7” 5” 6” 7” 8” 5” 6” 7” 8” 9” 7” 8” 9” 10” A = Small end diameter B = Large end diameter S = 1-1/2” L = 1-1/2”  Galvanized, 20 ga. Materials Available Key  Sizes 4” to 16”  Male (small ends) fit into spiral pipe  Bead on large end is standard S L S – Product Specifications®10 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com 1-Piece Concentric Spun Reducer (CSPR/CSPRB)WeightEach 2.8# 2.8# 2.8# 2.8# 3.3# 3.3# 3.3# 3.9# 3.9# 3.9# 4.3# 4.3# 4.8# 4.8# 5.5# 5.5# 6.0# 6.0# (B) 12” 12” 12” 12” 14” 14” 14” 16” 16” 16” 18” 18” 20” 20” 22” 22” 24” 24” (A) 7” 8” 9” 10” 9” 10” 12” 12” 14” 15” 14” 16” 16” 18” 18” 20” 20” 22” WeightEach 1.0# 1.3# 1.3# 1.5# 1.5# 1.5# 1.8# 1.8# 1.8# 1.8# 2.0# 2.0# 2.0# 2.0# 2.2# 2.2# 2.2# 2.2# 2.6# 2.6# 2.6# 2.6# 2.6# (B) 4” 5” 5” 6” 6” 6” 7” 7” 7” 7” 8” 8” 8” 8” 9” 9” 9” 9” 10” 10” 10” 10” 10” (A) 3” 3” 4” 3” 4” 5” 3” 4” 5” 6” 4” 5” 6” 7” 5” 6” 7” 8” 5” 6” 7” 8” 9” Sizes For CSPR/CSPRB Only A L B L S S A = Small end diameter B = Large end diameter L = 4” S = 3”  Galvanized, 20 ga. Materials Available Key  Sizes 4” to 24”  Male (small ends) fit into spiral pipe  Bead available on large end upon  request (CSPRB) Options Available – Product Specifications®11 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com A = Diameter R = Radius F = Flange length Materials Available Key Options Available  Sizes 4” to 36”  Dampers (see BTOBD spec)  Peel & stick gasket is standard on BTOB (4”- 14”)  2” Stand-off (see BTOBD spec)  Bead or no bead B = Overall width H = Overall height T = Flange thickness (gauge) Bellmouth Take-Off (BTOB & BTONB)  Galvanized (4”- 12”), 24 ga., stamped  Galvanized (14”- 36”), 20 ga., spun (A) 4” 5” 6” 7” 8” 9” 10” 12” 14” 16” 18” 20” 22” 24” 26” 28” 30” 32” 34” 36” (H) 2-1/4” 2-1/2” 4-1/4” 3-1/2” 4-1/2” 3-1/2” 4-3/4” 5-1/2” 6-1/2” 8-1/2” 8-1/2” 8-1/2” 8-1/2” 8-1/2” 8-1/2” 8-1/2” 8-1/2” 8-1/2” 8-1/2” 8-1/2”  4”, 5”, 7” & 9” are short BTO’s  Peel & stick gasket is not available on 16”-36” Dimensions WeightEach 0.4# 0.7# 0.8# 0.7# 1.1# 0.9# 1.5# 2.0# 3.2# 4.4# 5.4# 6.2# 7.0# 7.4# 8.0# 8.0# 10.0# 10.0# 11.0# 11.0# (B) 6.5” 8.25” 8.5” 10.5” 11” 13” 13.5” 14.5” 17” 20” 22” 24” 26” 28” 30” 32” 34” 36” 38” 40” (F) 1” 1” 1” 1” 1” 1” 1” 1” 1” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” (R) .394” .472” .787” 1.0” 1.0” 1.0” 1.0” 1.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” (S) 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” A S F B H R – Product Specifications®12 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com Bellmouth Take-Off with Damper (BTOBD) Materials Available Key Options Available  Sizes 4” to 36”  Peel & stick gasket is standard on BTOBD (4”- 14”)  2” Stand-off, BTOD2S (see shaft extension handle  drawing to the left)  See Volume Damper (VD) spec A = Diameter R = Radius F = Flange length B = Overall width H = Overall height T = Flange thickness (gauge)  Galvanized (4”- 12”), 24 ga., stamped  Galvanized (14”- 36”), 20 ga., spun A F OPTION: 2” Shaft Extension Handle (BTOD2S) 2” B (A) 4” 5” 6” 7” 8” 9” 10” 12” 14” 16” 18” 20” 22” 24” 26” 28” 30” 32” 34” 36”  4”, 5”, 7” & 9” are short BTO’s  Peel & stick gasket is not available on 16”-36” Dimensions (B) 6.5” 8.25” 8.5” 10.5” 11” 13” 13.5” 14.5” 17” 20” 22” 24” 26” 28” 30” 32” 34” 36” 38” 40” (H) 8” 8-1/2” 4-1/4” 9” 4-1/2” 9” 4-3/4” 5-1/2” 6-1/2” 8-1/2” 8-1/2” 8-1/2” 8-1/2” 8-1/2” 8-1/2” 8-1/2” 8-1/2” 8-1/2” 8-1/2” 8-1/2” WeightEach 1.0# 1.2# 1.0# 2.4# 1.4# 3.0# 2.1# 2.6# 4.2# 6.4# 7.4# 8.2# 9.0# 9.4# 13.0# 13.0# 17.0# 17.0# 21.0# 21.0# (F) 1” 1” 1” 1” 1” 1” 1” 1” 1” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” (R) .394” .472” .787” 1.0” 1.0” 1.0” 1.0” 1.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” (S) 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” R S H 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com – Product Specifications®13 Features  2” Stand-off (20 ga.)  Nylon bushings with O-ring for  sealing of holes  Locking handle for adjustment of  damper - ease of balancing 3/8” Continuous square rod through  damper  4”- 22” Standard dampers (22 ga.)  24”- 36” Standard dampers (20 ga.)  22 Gauge galvanized body Low-Leakage Dampers (R) .394” .472” .787” 1.0” 1.0” 1.0” 1.0” 1.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” 2.0” (A) 4” 5” 6” 7” 8” 9” 10” 12” 14” 16” 18” 20” 22” 24” 26” 28” 30” 32” 34” 36” (S) 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” (B) 6.5” 8.25” 8.5” 10.5” 11” 13” 13.5” 14.5” 17” 20” 22” 24” 26” 28” 30” 32” 34” 36” 38” 40” (F) 1” 1” 1” 1” 1” 1” 1” 1” 1” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” 1.5” (L) 4” 4” 4” 4” 4” 4” 4” 4” 4” 4” 4” 4” 4” 4” 4” 4” 4” 4” 4” 4” Dimensions (H) 7.875” 8.25” 9.875” 9.125” 10.125” 9.125” 10.375” 11.125” 12.125” 14.125” 14.125” 14.125” 14.125” 14.125” 14.125” 14.125” 14.125” 14.125” 14.125” 14.125” F B L A S R H Bellmouth Take-Off with Damper (BTOD) – Product Specifications®14 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com A1 = Branch (nominal) size A2 = Pipe (nominal) size  Galvanized, 24 ga. Materials Available Key Options Available  Damper collars in 6” lengths (see  DSTDC6 spec)  Bead or no bead R = Radius F = Flange on pipe R = 0.787” (4 on 4 – 6 on 20/22/24), R = 1.0” (8 on 8 – 12 on 22/24) F = 1.0” (4 on 4 – 8 on 20/22/24), F = 2.0” (10 on 10 – 12 on 22/24) S = 1-1/4” (4 on 4 – 5 on 16/24), S = 1-1/2” (6 on 6 – 12 on 22/24) 90o Die Stamped Saddle Tap (DSTB & DSTNB) A1 A2 FR A1 A2 H WeightEach 0.4# 0.4# 0.4# 0.4# 0.4# 0.4# 0.4# 0.7# 0.7# 0.7# 0.7# 0.7# 0.7# 0.8# 0.8# 0.7# 0.7# 0.6# 1.1# 1.3# 1.1# 1.1# 1.0# 1.8# 2.0# 1.8# 1.8# 1.7# 2.3# 2.0# 2.3# 2.1# (A1) 4” 4” 4” 4” 4” 4” 4” 5” 5” 5” 5” 5” 5” 6” 6” 6” 6” 6” 8” 8” 8” 8” 8” 10” 10” 10” 10” 10” 12” 12” 12” 12” Dimensions (A2) 4” 5” 6”- 7” 8” 9”- 10” 12”- 14” 16”- 24” 5” 6”- 7” 8”- 9” 10” 12”- 14” 16”- 24” 6” 8” 10”- 12” 14”- 18” 20”- 24” 8” 10” 12”- 14” 16”- 18” 20”- 24” 10” 12” 14”- 16” 18”- 20” 22”- 24” 12” 14”- 16” 18”- 20” 22”- 24” (H) 2” 2” 2” 2” 2” 2” 2” 2-1/8” 2-1/8” 2-1/8” 2-1/8” 2-1/8” 2-1/8” 3-1/8” 3-1/8” 3-1/8” 3-1/8” 3-1/8” 3-3/8” 3-3/8” 3-3/8” 3-3/8” 3-3/8” 3-3/8” 3-3/8” 3-3/8” 3-3/8” 3-3/8” 3-1/2” 3-1/2” 3-1/2” 3-1/2” S – Product Specifications®15 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com A1 = Branch size A2 = Pipe size F = Flange on pipe H = Height R = Radius  Galvanized, 24 ga. Materials Available Key R = 0.787” (4 on 4 – 6 on 20/22/24), R = 1.0” (8 on 8 – 12 on 22/24) F = 1.0” (4 on 4 – 8 on 20/22/24), F = 2.0” (10 on 10 – 12 on 22/24) S = 1-1/4” (4 on 4 – 5 on 16/24), S = 1-1/2” (6 on 6 – 12 on 22/24) H = 6” (where A1 is 4”- 5”) H = 7” (where A1 is 6”- 12”)  2” Stand-offs, DSTD2S (see shaft  extension handle drawing above) Options Available 90o Die Stamped Saddle Tap with Damper (DSTDC6) A1 S A2 F R 1/2” offset OPTION: 2” Shaft Extension Handle (DSTD2S) 2” A1 A2 H WeightEach 0.8# 0.8# 0.8# 0.8# 0.8# 0.8# 0.8# 1.3# 1.3# 1.3# 1.3# 1.3# 1.3# 1.6# 1.6# 1.5# (A1) 4” 4” 4” 4” 4” 4” 4” 5” 5” 5” 5” 5” 5” 6” 6” 6” (A2) 4” 5” 6”-7” 8” 9”- 10” 12”- 14” 16”- 24” 5” 6”- 7” 8”- 9” 10” 12”- 14” 16”- 24” 6” 8” 10”- 12” WeightEach 1.4# 1.4# 2.1# 2.3# 2.1# 2.1# 2.0# 3.0# 3.2# 3.0# 3.0# 2.9# 3.7# 3.4# 3.7# 3.5# (A1) 6” 6” 8” 8” 8” 8” 8” 10” 10” 10” 10” 10” 12” 12” 12” 12” (A2) 14”- 18” 20”- 24” 8” 10” 12”- 14” 16”- 18” 20”- 24” 10” 12” 14”- 16” 18”- 20” 22”- 24” 12” 14”- 16” 18”- 20” 22”- 24” Dimensions 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com – Product Specifications®16 Features  2” Stand-off (20 ga.)  Nylon bushings with O-ring for sealing of holes  Locking handle for adjustment of damper - ease  of balancing 3/8” Continuous square rod through damper  4”- 22” Standard dampers (22 ga.)  24”- 36” Standard dampers (20 ga.)  22 Gauge galvanized body Low-Leakage Dampers Key (DSTD) A1 = 4”, 5”, 6”, 8”, 10”, 12” A2 = Up to 24” (A2 is greater than or equal to A1) S = 2” H = see chart L = 4” * Field installed fitting A2 A1 S 90o Die Stamped Saddle Tap with Damper (DSTD) H L Dimensions (A1) 4” 5” 6” 8” 10” 12” (H) 7-3/4” 7-7/8” 8-3/4” 9” 9” 9-1/8” – Product Specifications®17 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com A = Diameter B = 3/4” (flange length) L = 4” S1 = 2” S2 = 1-1/4” Materials Available Key Options Available  Sizes 3” to 22”  Total length = 7-1/4”  Male (small ends) to fit into spiral pipe Conical Take-Off (CTO)  Galvanized (3”- 22”), 20 ga., spun Dimensions (L) 4” 4” 4” 4” 4” 4” 4” 4” 4” 4” 4” 4” 4” 4” (S1) 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” (B) 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” (A) 3” 4” 5” 6” 7” 8” 9” 10” 12” 14” 16” 18” 20” 22” WeightEach 1.0# 1.3# 1.5# 1.7# 1.8# 1.9# 2.0# 2.1# 2.2# 2.5# 2.7# 2.8# 3.3# 3.7# (S2) 1-1/4” 1-1/4” 1-1/4” 1-1/4” 1-1/4” 1-1/4” 1-1/4” 1-1/4” 1-1/4” 1-1/4” 1-1/4” 1-1/4” 1-1/4” 1-1/4” B A S1 S2 L – Product Specifications®18 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com A = Diameter BxC = Base H = Height HET - No damper HETD - With damper Key Options Available  2” Stand-off, HETD2S (see shaft  extension handle drawing to the left) 1” wide flange aroundrectangular endgasket seal aroundperimeter H A BxC Dimensions (H) 9-1/4” 9-1/2” 9-1/4” 9-1/4” 9-1/4” 10-1/2” 10-1/4” 10-1/4” 10-1/2” 13” (BxC) 10”x5” 10”x5” 12”x6” 12”x6” 12”x6” 15”x6” 16”x6-3/4” 18”x8-1/2” 20”x9-1/2” 22”x14” (A) 4” 5” 6” 7” 8” 9” 10” 12” 14” 16” 26 Ga.Weight 1.04# 1.60# 1.80# 2.00# 2.20# 2.80# 3.00# 3.60# 4.20# 6.60#  Galvanized, 26 ga.  Complete with peel & stick neoprene  gasket Materials Available  Togglelock seam Construction High Efficiency Take-Off (HET) High Efficiency Take-Off (HETD) OPTION: 2” Shaft Extension Handle (HETD2S) 2” 1” wide flange aroundrectangular endgasket seal aroundperimeter H A BxC – Product Specifications®19 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com End Cap/Plug (ECP) 13/4” A B A = Small end to fit in spiral pipe, - 1/8” (Plug) B = Large end to fit over spiral pipe, A = +1/8” (Cap)  Galvanized, 24 ga. Materials Available Key  Sizes 3” to 30” Options Available Dimensions NominalSize 3” 4” 5” 6” 7” 8” 9” 10” 12” 14” 16” 18” 20” 22” 24” 26” 28” 30” (B) 3-1/8” 4-1/8” 5-1/8” 6-1/8” 7-1/8” 8-1/8” 9-1/8” 10-1/8” 12-1/8” 14-1/8” 16-1/8” 18-1/8” 20-1/8” 22-1/8” 24-1/8” 26-1/8” 28-1/8” 30-1/8” (A) 2-7/8” 3-7/8” 4-7/8” 5-7/8” 6-7/8” 7-7/8” 8-7/8” 9-7/8” 11-7/8” 13-7/8” 15-7/8” 17-7/8” 19-7/8” 21-7/8” 23-7/8” 25-7/8” 27-7/8” 29-7/8” WeightEach .20# .20# .35# .50# .60# .70# .85# 1.05# 1.40# 1.80# 2.20# 2.70# 3.40# 4.00# 4.50# 5.20# 5.88# 6.60# A BB – Product Specifications®20 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com Coupling (CM/CF) Materials Available Key Dimensions (A) 3” 4” 5” 6” 7” 8” 9” 10” 12” 14” 16” 18” 20” 22” 24” 26”- 30” (S) 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” 2” WeightEach 0.8# 1.0# 1.3# 1.5# 1.7# 2.0# 2.2# 2.5# 3.0# 3.5# 3.9# 4.5# 4.9# 5.7# 6.7# N/A A = Diameter S = 2”  4” overall length is standard  Stitch welded construction Male Coupling – For pipe, the ends are 1/8” undersize to fit inside spiral pipe. Bead is located at 2”. Female Coupling – For pipe, the ends are 1/8” oversize to fit over spiral pipe. Reverse bead located at 2”. Female Coupling A 4” SS A 4” Male Coupling SS AA  Galvanized  Galvaneal  Stainless Steel 304 & 316  Aluminum 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com A = Branch size B = Pipe size  Galvanized (24 ga.), Galvaneal, Stainless  Steel 304 & 316, Aluminum  SE x +/- 1/2” flange out Materials Available Key Dimensions (A) 3” 4” 5” 6” 7” 8” 9” 10” 11” 12” 13” 14” WeightEach 0.92# 1.08# 1.23# 1.54# 1.85# 2.16# 2.77# 3.08# 3.39# 3.70# 4.01# 4.32# Dimensions (A) 16” 18” 20” 22” 24” 26” 28” 30” 32” 34” 36” WeightEach 4.93# 5.55# 6.16# 6.78# 7.40# 9.94# 10.70# 11.47# 12.23# 13.00# 13.76# Fabricated 45o Saddle Tap (ST45) Volume Damper (VD)AB2”1/2”4”– Product Specifications®21 Shown with hardware installed 5/16” hardware and handle are included (loose) AA Specs  4” to 12” – Galvanized, 26 ga.  14” to 36” – Galvanized, 24 ga. Materials Available  2” Stand-off with loose hardware (see spec  below)  Sizes 4” to 10” (all sizes), 12” to 36” (even  sizes only)  VD Kit which includes:  1 - Volume Damper blade  1 - 5/16” washer  2 - 5/16” wingnut washers  1 - Damper handle Options Available A = Diameter Key OPTION: 2” Shaft Extension 2”  5/16” OD shaft extension  1 - 3/4” plastic sleeve (.875” OD x .75” ID x 1.75” length) 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com – Product Specifications®22 A3 A2 L H S A1 A1 H A2 * Field installed fitting A2 A1 L H 90o Conical (C)90o Conical Tee (CT) 90o Conical Reducing Tee (CRT) X S S S S Key (C) Key (CRT) A1, A2 & A3 = Diameter A1 is greater than A3 A2 is less than A1 S = 2” H = 5-1/4” L = A3 + 4” X = A1 - A2 (4” minimum) A1 & A2 = Diameter A2 is greater than A1 S = 2” H = 6” Key (CT) A1 & A2 = Diameter A1 is greater than A2 S = 2” H = 5-1/4” L = A2 + 4”  Galvanized, Galvaneal, Stainless Steel  304 & 316, Aluminum Materials Available 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com – Product Specifications®23 Features  2” Stand-off (20 ga.)  Nylon bushings with O-ring for sealing of holes  Locking handle for adjustment of damper - ease  of balancing 3/8” Continuous square rod through damper  4”- 22” Standard dampers (22 ga.)  24”- 36” Standard dampers (20 ga.)  22 Gauge galvanized body Low-Leakage Dampers Key (CD) Sizes Available for A1: 4”- 10” (all sizes), 12”- 36” (even sizes only) A2 is greater than A1 S = 2” H = 6” L = 4” H A2 * Field installed fitting A1 LL S 90o Conical with Damper (CD) S H A2A1 A3 A 3S 45o angle HA 4S A2A1 A3 A2 S H A1 A4 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com – Product Specifications®24 Conical Cross (CROSC)Straight Cross (CROSS) 45o Lateral Cross (CROSL) A4 L L L S S S Key (All) A1 & A2 are greater than or equal to A3 & A4 L = A3 + 4” Key (CROSS) A1 & A2 are greater than or equal to A3 & A4 L = (A3 x 1.414) + 4” Key (CROSL) A1, A2, A3 & A4 = Diameter A3 is greater than or equal to A4 S = 2” H = 4” A1 & A2 are greater than A3 & A4 (= 2” min.) L = A3 + 4” Key (CROSC) Materials Available  Galvanized, Galvaneal, Stainless Steel  304 & 316, Aluminum 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com – Product Specifications®25 45o Lateral (L) 45o Lateral Reducing Tee (LRT) * Field installed fitting 45o Lateral Tee (LT) A2A1SH A1A2S L 45o angle HA2A3S L HS 45o angle A1 X S A1 & A2 = Diameter A2 is greater than or equal to A1 S = 2” H = 4” Key (L) A1, A2 & A3 = Diameter A1 is greater than or equal to A3 A2 is less than A1 S = 2” H = 4” L = A3 + 4” X = A1 - A2 (4” minimum) Key (LRT) A1 & A2 = Diameter A1 is greater than or equal to A2 S = 2” H = 4” L = A2 + 4” Key (LT) Materials Available  Galvanized, Galvaneal, Stainless Steel  304 & 316, Aluminum 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com – Product Specifications®26 Features  2” Stand-off (20 ga.)  Nylon bushings with O-ring for sealing of holes  Locking handle for adjustment of damper - ease  of balancing 3/8” Continuous square rod through damper  4”- 22” Standard dampers (22 ga.)  24”- 36” Standard dampers (20 ga.)  22 Gauge galvanized body Low-Leakage Dampers Key (LD) Sizes Available for A1: 4”- 10” (all sizes), 12”- 36” (even sizes only) A2 is greater than or equal to A1 S = 2” H = 4” L = 4” * Field installed fitting A2HLA1S45oLateral with Damper (LD) Reducing Conical Cross (RCC) Reducing Straight Cross (RCS) S H A2A1 A3 A4 S A 3S 45o angle HA 4S S A2A1 A3 A2 S H A1 A4 S – Product Specifications®27 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com Reducing 45o Lateral Cross (RCL) X L L L X X A1, A2, A3 & A4 = Diameter A2 is less than A1 A3 is greater than or equal to A4 S = 2” H = 4” X = A1 - A2 (4” min.) Key (All) A1 is greater than A3 & A4 (= 2” min.) L =A3 + 4” Key (RCC) A1 is greater than or equal to A3 & A4 L = (A3 x 1.414) + 4” Key (RCL) A1 is greater than or equal to A3 & A4 L =A3 + 4” Key (RCS) Materials Available  Galvanized, Galvaneal, Stainless Steel  304 & 316, Aluminum 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com – Product Specifications®28 Concentric Reducer (R) A2 A1 S S L A2 A1 S S L Eccentric Reducer (ER) A1 = Diameter A2 = Diameter S = 2” L = 4” if the change in diameter (A1 - A2) is less  than 6”  If the change in diameter (A1 - A2) is greater  than or equal to 6” then L=A1 - A2.  Please specify any other length, if not the  standard. Key (R) Materials Available  Galvanized  Galvaneal  Stainless Steel 304 & 316  Aluminum A1 = Diameter A2 = Diameter S = 2” L = (A1 - A2) x 2 + 2” L minimum = 7-3/4” Please specify any other length, if not the standard. Key (ER) Materials Available  Galvanized  Galvaneal  Stainless Steel 304 & 316  Aluminum 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com – Product Specifications®29 * Field installed fitting A2 A1 S H A2 A1 L S H Straight Tap (ST)90o Tee (T) S A1 & A2 = Diameter A2 is greater than or equal to A1 S = 2” H = 2” Key (ST) A1, A2 & A3 = Diameter A1 is greater than or equal to A3 A2 is less than A1 S = 2” H = 2” L = A3 + 4” X = A1 - A2 (4” minimum) Key (SRT) A1 & A2 = Diameter A1 is greater than or equal to A2 S = 2” H = 2” L = A2 + 4” Key (T) 90o Straight Reducing Tee (SRT) A3 A2 L S HS A1 X Materials Available  Galvanized, Galvaneal, Stainless Steel  304 & 316, Aluminum 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com – Product Specifications®30 Features  2” Stand-off (20 ga.)  Nylon bushings with O-ring for sealing of holes  Locking handle for adjustment of damper - ease  of balancing 3/8” Continuous square rod through damper  4”- 22” Standard dampers (22 ga.)  24”- 36” Standard dampers (20 ga.)  22 Gauge galvanized body Low-Leakage Dampers Key (STD) Sizes Available for A1: 4”- 10” (all sizes), 12”- 36” (even sizes only) A2 is greater than or equal to A1 S = 2” H = 4” L = 4” 90o Straight Tap with Damper (STD) * Field installed fitting A2 L S A1 H 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com – Product Specifications®31 90o Reducing Tee with Die Stamped Saddle Tap (DSTRT) A2 A3 S S H A1 A1 = Up to 24” (A1 is greater than or equal to A3) A2 = Up to 24” (A2 is less than A1) A3 = 4”, 5”, 6”, 8”, 10”, 12” S = 2” H = 3/4” (where A3 = 6” or less), H = 1” (where A3 = 8” or more) L = A3 + 4” X = A1 - A2 (4” minimum) Key (DSTRT) A1 = Up to 24” (A1 is greater than or equal to A2) A2 = 4”, 5”, 6”, 8”, 10”, 12” S = 2” H = 3/4” (where A1 = 6” or less), H = 1” (where A1 = 8” or more) L = A2 + 4” Key (TDST) A1 A2 S S H L 90o Tee with Die Stamped Saddle Tap (TDST) L X 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com – Product Specifications®32 A3A2A1 S A1, A2 & A3 = Diameter S = 2” KeyY Branch (Y) A1, A2 & A3 = Diameter A2 & A3 are less than A1 S = 2” Key A1 SA2 A3Reducing Y Branch (RY) Materials Available Materials Available  Galvanized  Galvaneal  Stainless Steel 304 & 316  Aluminum  Galvanized  Galvaneal  Stainless Steel 304 & 316  Aluminum 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com – Product Specifications®33 A Balancing Damper Section - Large End/Small End (D1) S L S L A Balancing Damper Section (D) A = 4”- 10” (all sizes), 12”- 36” (even sizes only) S = 2” L = 4” Key Materials Available  2” Stand-off (20 ga.)  Nylon bushings with O-ring for sealing  of holes  Locking handle for adjustment of damper -  ease of balancing 3/8” Continuous square rod through damper  4”- 22” Standard dampers (22 ga.)  24”- 36” Standard dampers (20 ga.) Low-Leakage Dampers  Galvanized (22 ga.), Galvaneal, Stainless  Steel 304 & 316, Aluminum A = 4”- 10” (all sizes), 12”- 36” (even sizes only) S = 2” L = 6” Key Materials Available  2” Stand-off (20 ga.)  Nylon bushings with O-ring for sealing  of holes  Locking handle for adjustment of damper -  ease of balancing 3/8” Continuous square rod through damper  4”- 22” Standard dampers (22 ga.)  24”- 36” Standard dampers (20 ga.) Low-Leakage Dampers  Galvanized (22 ga.), Galvaneal, Stainless  Steel 304 & 316, Aluminum 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com – Product Specifications®34 Key S = 2” L = A + 4” X = 4” minimum A3 > A1 or A2 Order as: in, out, branch (A1, A2, A3) Materials Available  Galvanized  Galvaneal  Stainless Steel 304 & 316  Aluminum Straight Take-off (STO) Reducing Bull Head Tee (BRT) L XX SS A3 A1 A2 S A (1/2” Flange) S Key A = 4”- 36” S = 2” Materials Available  Galvanized  Galvaneal  Stainless Steel 304 & 316  Aluminum – Product Specifications®35 217 Lenox Avenue, Elmira Heights, NY 14903 Phone: 607.733.9988 Fax: 607.733.9967 www.stampedfittings.com End Cap (EC) End Plug (EP) A = Small end to fit in spiral pipe S = 2”  Galvanized  Galvaneal  Stainless Steel 304 & 316  Aluminum Materials Available Key S AA S AA A = Large end to fit over spiral pipe S = 2”  Galvanized  Galvaneal  Stainless Steel 304 & 316  Aluminum Materials Available Key        &ůĞdžƵĐƚ x x x DESCRIPTION All air duct installations for heating, cooling or ventilation are attached to mechanical equipment containing a fan or blower. Vibrations, noises and rattles resulting from operation of the fan or blower are transmitted into the metal ducts which carry the noises throughout the system. In order to isolate the vibration and noises to the source, an air - tight flexible joint,consistingofafabricwhichisattachedtosheetmetalonbothsides,must be inserted between the equipment and the ductwork. This vibration isolator is called a "Flexible Duct Connector". ®Submittal Form DDFDC FlexibleDuctConnector Fabric Comparisons Excelon Neoprene (Specification Grade)Durolon Insulflex Teflon Glasseal UL Classified Listing #R4462 R4462 UL Certified NFPA 701 n/a n/a R4462 Continuous Temp. Range -40 °F. to 180°F. -40 °F. to 200°F. -40 °F. to 250°F. -40 °F. to 180°F. -150 °F. to 500°F. -40 °F. to 180°F. Color Black Black White Black Grey Outside/Beige Inside Grey & Black Commercial Grade Weight 22 oz. 30 oz. 26 oz.28 oz. (composite weight)16.5 oz. 16 oz. Residential Grade Weight 17 oz. 30 oz. 26 oz.28 oz. (composite weight)16.5 oz. 16 oz. Abrasion Resistance1 15,000 cycles 600 cycles 500 cycles 500 cycles 1,000 cycles 1,400 cycles Leakage Resistance2 350 595 250 125 650 120 Tear Strength3 100 lbs. / 100 lbs. 12 lbs. / 12 lbs. 12 lbs. / 12 lbs. 8 lbs. / 11 lbs. 50 lbs. / 30 lbs. 8 lbs. / 9 lbs. Tensile Strength4 240 lbs. / 220 lbs. 500 lbs. / 450 lbs. 225 lbs. / 300 lbs. 70 lbs. / 70 lbs. 400 lbs. / 300 lbs. 90 lbs. / 90 lbs. Base Fabric Woven Nylon/Polyester Blend Woven Fiberglass Woven Fiberglass Polyester Fiberglass/Satin Weave Woven Fiberglass Coating Vinyl Neoprene Hypalon Vinyl Teflon Vinyl Features • Excellent water resistance • Excellent tear strength • Excellent all purpose fabric • Unaffected by mildew • Extremely resistant to alkalies & gasoline • Excellent on systems exposed to toxic fumes • Good general purpose fabric • Unaffected by mildew • Excellent ozone & weathering resistance • Best overall acid resistance • Recommended for rooftop applications • Unaffected bymildew • Low Smoke Emission • Insulated 3-4-3 Configuration • High temperature resistant • High corrosion resistance • Excellent chemical resistance • Good, lowcost • Resistanttoacids & chemical fumes • Resistant togrease & alkalies • Unaffected bymildew Metal-Fab® Grip Loc MBX333 (#10159) MFN333 (#10003) MFD333 (#10002) IDC343 (#10173) *Gauge: 28 +Guard Loc MCT333 (#10278) MGL333 (#10004) Super Metal-Fab® Grip Loc MB6X363 (#10160) MB12X3123 (#10252) MF6N363 (#10012) MFN12N3123 (#10251)MF6D363 (#10011) Not Available Not Available MF6G363 (#10016) TDC/TDF Grip Loc MBX444 (#10210) MBX464 (#10214) MBX484 (#10280) MBX4104 (#10286) MFN444(#10211) MFN464 (#10246) MFN484 (#10281) MFN4124 (#10254) MFD444 (#10237) MFD464 (#10245)Not Available MCT444 (#10279) MCT4104 (#10287)Not Available Please see individual submittals for each fabric/configuration for flame/smoke test results (ASTM E84 rating & NFPA 701). All Metal-Fab, Super Metal-Fab and TDC/TDF Flexible Duct Connectors are manufactured with 24 gauge galvanized steel. Duro Dyne meets or exceeds the SMACNA steel requirements for flexible duct connector. Other materials are available upon request. Notes: 1. Abrasion resistance as per Federal Test Standard 191 Method #5306 using CS 17 wheel with 250 Gramload. 2. Leakage resistance as per Federal Test Standard 191 Method #5512. Results in P.S.I. (To convert inches of water multiply P.S.I. x 27.176.). 3. Tear strength in tongue pounds as per Federal Test Standard 191 Method #5134.1 (warp/fill). 4. Tensile strength in grab pounds as per Federal Test Standard 191 Method #5100 (warp/fill). 5. Standard Excelon is not LA city approved. Use Excelon-LA when LA city approval is necessary. (See Specification Form Excelon-LA -203) SUGGESTED SPECIFICATION Vibration Isolating Flexible Duct Connector For Heating, Cooling & Exhaust Supplies & Returns. At the inlet and discharge of all air handling equipment (unless otherwise noted) furnish and install vibration isolators. Vibration isolators shall be a coated woven fabric named and shall be "Underwriters Laboratories Classified". Vibration isolators shall have a tear strength of not less then , and a continuous temperature range of_________ _ .Vibration isolators shall be preassembled metal to exposed fabric to metal. Fabric and metal shall be joined by means of a double lock seam. Vibration isolators shall be code _________ ( called Flexible Duct Connectors) as manufactured by Duro Dyne Corporation, Bay Shore,N.Y. I C All Duro Dyne Flexible Duct Connector Products are suitable for pressures of -10 to +15 wg. Duro Dyne's standard ‘single fold’ metal to fabric grip has been tested by an independent testing laboratory to withstand a negative pressure of -10’’WC and a positive pressure of +17.25’’ WC with no tearing or visible separation. I CHEMICAL RESISTANCE ( X = Extremely Resistant) ( NR = Not Recommended) ( O = No DataAvailable) ® Specifications All Listed Duro Dyne Flexible Duct Connector Fabrics are designed to meet the following specifications: 1. MIL-C-20696B Para. 4.4.3. (Oil Resistance). 2. MIL-C-20696B Para. 4.4.4. (Hydro Carbon Resistance). 3. NFPA701 Tests for Flame Propagation of Fabrics and film (exceptTeflon). 4. California State Fire MarshalApproved. 5. Los Angeles City Approved. (*See notebelow) 6. Denver CityApproved. All Duro Dyne Flexible Duct Connectors utilize galvanized steel meeting ASTM-A-525 G 60 or better. Duro Dyne Flexible Duct Connectors are also available with 300 series stainless steel or 3003 aluminum upon request. **Note-StandardExcelonisnotLAcityapproved.UseExcelon-LAwhenLAcityapproval is necessary. (See Submittal Form for Excelon-LA) Chemical Chemical Acetic Acid NR X X NR X NR Hydrofluoric Acid (100%) NR X X NR X NR Aluminum Chloride X X X X X X Hydrogen Peroxide X NR X X NR X Aluminum Sulfate X X X X X X Hydrogen Sulfide X X X X X X Ammonia (Anhyd) X X X X X X Lactic Acid NR X X NR X NR Ammonium Hydroxide X X X X X XLinseed Oil NRXXNRONR Ammonium Sulfate X X X X X X Magnesium Chloride NR X X NR X NR Barium Sulfide XXXX X X Maleic Acid X NR X X O X Black Sulfate Liquor X X X X X XMethyl Alcohol NRXXNRXNR Boric Acid XXXX X X Methyl Cellosolve NR X X NR O NR Butyl Alcohol NR X X NR X NR Mineral Oil X X X X X X Cadmium Plating Solution X NR NR NR O X Naptha NRNRNRNR X NR Calcium Chloride X X X X X X Nickel Chloride X X X X X X Calcium Hypochlorite X NR X X X X Nickel Sulfate X X X X X X Chlorine Water X NR NR X O X Nitric Acid (40%) X NR X X X X Chromic Acid X NR X X X X Oleic Acid X NR NR X X X Chromium Plating Solution X O O NR O X Oleum NR NR X NR X NR Citric Acid X X X X X X Oxalic Acid X X X X X X Copper Chloride X X X X X X Phosphoric Acid (85%) NR X X NR X NR Copper Sulfate X X X X X X Pickling Solution X NR X X O X Cottonseed Oil XXXX O X Potassium Chloride X X X X O X Diacetone Alcohol NR X X NR O NR Potassium Cyanide X X X X X X Disodium Phosphate X NR NR X O X Potassium Dichromate X X X X X X Ethyl Alcohol NR X X NR X NR Potassium Hydroxide (40%) X X X NR X X Ethylene Glycol NR X X NR X NR Potassium Sulfate X X X X X X Ferric Chloride X X X X X XPropyl Alcohol NRXXNRONR Ferric Sulfate X X X X X XSodium Chloride XXXXXX Fluroboric Acid X X X NR O X Sodium Hydroxide (40%) NR X X NR X NR Formaldehyde (40%) X X X X X X Sodium Hypochlorite NR NR X NR X NR Formic Acid XXXX X X Steam NR X NR NR X NR Glucose X X X X X X Sulfur Dioxide (Liquid) NR X X NR X NR Glycerine NR X X NR X NR Sulfuric Acid (50%) X NR X NR X X Heptane NR X X NR X NR Sulfuric Acid (over 50%) NR NR X NR X NR Hexane NR X X NR X NR Tannic Acid X X X X X X Hydrobromic Acid (40%) NR X X NR X NR Vinegar X X X X X X Hydrochloric Acid (conc)NR X X NR X NR Duro Dyne Corporate Headquarters, Bay Shore, NY 631-249-9000 • Fax: 631-249-8346 Duro Dyne Midwest • Duro Dyne West • Duro Dyne Canada www.durodyne.com • E-mail: durodyne@durodyne.com ® ©2019 Duro Dyne Corporation Printed in USA11/12/19 BO010403 ɵ 6HOHFW'XUR'\QH)DEULFV DUHGHVLJQHGWRPHHW1)3$ IRUPHUO\8/ ɵ 6HOHFW'XUR'\QHIDEULFVDUHGHVLJQHGWRPHHW1)3$$ %5HIHUWRIDEULFFKDUWIRUUHODWHG$670(GDWD ɵ $OO'XUR'\QH)DEULFVDUHDLUWLJKWDQGZDWHUSURRI ɵ 'XUR'\QHPHHWVRUH[FHHGVWKH60$&1$VWHHOUHTXLUHPHQWVIRUÁH[LEOHGXFWFRQQHFWRU ɵ $OO'XUR'\QH)OH[LEOH'XFW&RQQHFWRUXWLOL]HRUJDXJHJDOYDQL]HGVWHHOPHHWLQJ$670$* ɵ 6WDQGDUGUROOOHQJWKIW ɵ &HUWDLQ&RQQHFWRUVDUHDYDLODEOHZLWK/VHULHVRU/VHULHVVWDLQOHVVVWHHORUDOXPLQXP  6HHFKDUWRQSDJHVIRUDYDLODELOLW\  ɵ )OH[LEOH'XFW&RQQHFWRULVPDQXIDFWXUHGLQWKH8QLWHG6WDWHVIRUDOOPDUNHWVDQGLQ  WKH8$(IRU0LG(DVWDQG2YHUVHDVPDUNHWV ɵ 9DQH5DLOLVPDQXIDFWXUHGLQWKH8QLWHG6WDWHV $OODLUGXFWLQVWDOODWLRQVIRUKHDWLQJFRROLQJRUYHQWLODWLRQDUHDWWDFKHGWRPHFKDQLFDO HTXLSPHQWFRQWDLQLQJDIDQRUEORZHU9LEUDWLRQVQRLVHVDQGUDWWOHVUHVXOWLQJIURP WKHRSHUDWLRQRIWKHIDQRUEORZHUDUHWUDQVPLWWHGLQWRWKHPHWDOGXFWVZKLFKFDUU\ WKHQRLVHVWKURXJKRXWWKHV\VWHP ,QRUGHUWRLVRODWHWKHYLEUDWLRQDQGQRLVHVWRWKHVRXUFHDQDLUWLJKWÁH[LEOHMRLQW FRQVLVWLQJRIDIDEULFZKLFKLVVHFXUHGWRVKHHWPHWDORQERWKVLGHVPXVWEHLQVHUWHG EHWZHHQWKHHTXLSPHQWDQGWKHGXFWZRUN7KLVÁH[LEOHMRLQWLVFDOOHGD)OH[LEOH'XFW &RQQHFWRU 7RPHHWHYHU\W\SHRILQVWDOODWLRQ UHTXLUHPHQWZKHWKHULWEHIRUIDFWRU\ LQVWLWXWLRQRIÀFHRUKRPH'XUR'\QH RIIHUVWKHZLGHVWYDULHW\RIIOH[LEOH GXFWFRQQHFWRUIDEULFV 8/&ODVVLÀHG  DQGVL]HVSUHDVVHPEOHGZLWKWKH VKHHWPHWDOSHUPDQHQWO\VHFXUHG WRWKHIDEULFE\PHDQVRIH[FOXVLYH VHDPORFNV'XUR'\QH)OH[LEOH'XFW &RQQHFWRUVDUHGLVSHQVHGIURPWKH FDUWRQUHDG\WRFRPSOHWHIDEULFDWLRQ IDVWHUPRUHHIILFLHQWO\DQGPRUH HFRQRPLFDOO\WKDQDQ\FRQYHQWLRQDO PHWKRG GUARD LOC™ $QRWKHU'XUR'\QHH[FOXVLYH6KLHOGHGZLWKPHWDORQERWKVLGHVDW WKHVHDP*XDUG/RFIRUPVDWRXJKPHWDOWRIDEULFERQG)RUPLQJLQD EUDNHLVVLPSOHUDQG*XDUG/RFSUHYHQWVWHDUVLQWKHIDEULFEHFDXVH RIXQLTXHPHWDOVKLHOGHGVHDPVGuard Loc is standard in Econ-O-Fab, -XQLRUDQG,QVXOÁH[&RQQHFWRU 0HWDOWR WR0HWDO &203$5(' TO 67$1'$5' 6,1*/( )2/' *5,3/2& GRIP LOC™ 7KHGRXEOHORFNJULSSLQJILQJHUVRIPHWDOWRIDEULFVDGGV WUHPHQGRXVO\WRWKHKROGLQJSRZHUFRPSDUHGWRWKHFRQYHQWLRQDO VLQJOHIROGPHWKRG*ULS/RFLVVWDQGDUGRQ0HWDO)DEDQG6XSHU 0HWDO)DE 35($66(0%/('FLEXIBLE DUCT CONNECTOR (/,0,1$7(6'8&76<67(012,6(6$1'9,%5$7,216 &219(17,21$/ *8$5'/2& 3$*( )/(;,%/('8&7&211(&725352'8&7&$7$/2* $OO'XUR'\QH)OH[LEOH'XFW&RQQHFWRU3URGXFWVDUHVXLWDEOHIRUSUHVVXUHVRIWRZJ'XUR'\QH·VVWDQGDUG¶VLQJOH IROG·PHWDOWRIDEULFJULSKDVEHHQWHVWHGE\DQLQGHSHQGHQWWHVWLQJODERUDWRU\WRZLWKVWDQGDQHJDWLYHSUHVVXUHRI ··:&DQGDSRVLWLYHSUHVVXUHRI··:&ZLWKQRWHDULQJRUYLVLEOHVHSDUDWLRQ 127($OOVSHFLÀFDWLRQYDOXHVVKRZQLQWKLVFDWDORJDUHW\SLFDODQGZLOOYDU\ZLWKLQDFFHSWHGFRPPHUFLDOWROHUDQFHV DUCTMATE • Double gasketed • Insulated • Competitively priced • Precision designed and manufactured • Variety of sizes available • Available in Specialty Metals Hinged, Cammed, & High Pressure Models Square Framed Access Doors Access Doors Hinge & Cam DESCRIPTION Low pressure access door for rectangular duct• 3” W.G. Positive• 2” W.G. Negative Cam Latches BASIC USE To provide easy access into air ducts and units. This door was developed as an inexpensive alternative to the Ductmate Sandwich® Access Door, for low pressure applications. TECHNICAL INFORMATION a. DOOR Consists of two, 24 gauge galvanized steel panels mechanically locked together b. INSULATION 1” High density fiberglass insulation with UL classification: FHC25/50 c. GASKET Closed cell cross-linked polyethylene gasket with a service temperature range of -70°F to 175°F. The gasket is bonded to the inside of both the Dovetail and Press-On frames and also to the outside of the Dovetail frame only. Double Sided Adhesive Gasket: Closed cell cross-linked polyethylene is UL94HF1 listed with a service temperature range of -110°F to 158°F. This gasket is bonded to the outside of the Press-On frame only. d. DOVETAIL FRAME Frames measuring 6” x 6” to 12” x 12” are manufactured from 24 gauge galvanized steel. Frames measuring 14” x 14” to 24” x 24” are manufactured from 22 gauge galvanized steel. All frames are manufactured with fastened corners for increased strength and an improved Dovetail design for easy installation on Metal Duct, 1” Duct Board or 1½” Duct Board. e. PRESS-ON FRAME Frames measuring 6” x 6” to 12” x 12” are manufactured from 24 gauge galvanized steel. Frames measuring 14” x 14” to 24” x 24” are manufactured from 22 gauge galvanized steel. A durable double sided adhesive gasket allows for easy installation to metal ductwork. f. HINGE Full length galvanized steel piano hinge is secured to both the frame and the door g. CAM & LATCH The cam is manufactured from 16 gauge galvanized steel and the latch is manufactured from 20 gauge galvanized steel. Each cam is secured to the door with a rivet. The latch is securely fastened to the frame. SPECIAL CHARACTERISTICS • Insulated• Double gasketed• Meets SMACNA requirements for low pressure doors• Dovetail frames are available for Metal Ductwork, 1” Duct Board or 1½” Duct Board• Press-On frames are available for metal ductwork only DESCRIPTION Low pressure access door for rectangular duct.• 3” W.G. Positive• 2” W.G. Negative BASIC USE To provide easy access into air ducts and units. This door was developed as an inexpensive alternative to the Ductmate Sandwich® Access Door, for low pressure applications. TECHNICAL INFORMATION a. DOOR Consists of two, 24 gauge galvanized steel panels mechanically locked together b. INSULATION 1” High density fiberglass insulation with UL classification: FHC25/50 c. GASKET Closed cell cross-linked polyethylene gasket with a service temperature range of -70°F to 175°F. The gasket is bonded to the inside of both the Dovetail and Press-On frames and also to the outside of the Dovetail frame only. Double Sided Adhesive Gasket: Closed cell cross-linked polyethylene is UL94HF1 listed with a service temperature range of -110°F to 158°F. This gasket is bonded to the outside of the Press-On frame only. d. DOVETAIL FRAME Frames measuring 6” x 6” to 12” x 12” are manufactured from 24 gauge galvanized steel. Frames measuring 14” x 14” to 24” x 24” are manufactured from 22 gauge galvanized steel. All frames are manufactured with fastened corners for increased strength and an improved Dovetail design for easy installation on Metal Duct, 1” Duct Board or 1½” Duct Board. e. PRESS-ON FRAME Frames measuring 6” x 6” to 12” x 12” are manufactured from 24 gauge galvanized steel. Frames measuring 14” x 14” to 24” x 24” are manufactured from 22 gauge galvanized steel. A durable double sided adhesive gasket allows for easy installation to metal ductwork. f. CAM & LATCH The cam is manufactured from 16 gauge galvanized steel and the latch is manufactured from 20 gauge galvanized steel. Each cam is secured to the door with a rivet. The latch is securely fastened to the frame. SPECIAL CHARACTERISTICS • Insulated• Double gasketed• Meets SMACNA requirements for low pressure doors• Dovetail frames are available for Metal Ductwork, 1” Duct Board or 1½” Duct Board• Press-On frames are available for metal ductwork only Distributed By: Ductmate Is A Proud Member Of The Following Organizations: This spec data is printed on paper that meets the Certified Fiber Sourcing requirements of the SFI program. 10% ® Charleroi, PA 210 Fifth Street Charleroi, PA 15022 724-258-0500 Lodi, CA 810 S. Cluff Avenue Lodi, CA 95240-9141 209-333-4680 Additional Manufacturing and Warehousing in Monongahela, PA and Wagoner, OK 1-800-245-3188 • www.ductmate.com © Copyright Ductmate Industries, Inc. All rights reserved.214 - 02/17 1. Without removing the cover from the adhesive backed gasket, place the opened door frame on the duct and trace around the inside of the frame. 2. Using a hand held plasma cutter or by conventional methods, cut the hole for the frame. 3. Remove the cover from the adhesive backed gasket tape. 4. Open the door and place the frame over the hole you cut in step 2. 5. Using zip screws, permanently attach the frame to the ductwork. Doors 16” and smaller require one screw at each corner and one at center on each side. Doors 18” to 36” require one screw at each corner with three screws evenly spaced on each side of the frame. 6. Close the door and latch. INSTALLATION INSTRUCTIONS FOR DOVETAIL FRAMES INSTALLATION INSTRUCTIONS FOR PRESS-ON FRAMES 1. Trace the frame of the access door onto the duct. 5. Close the door and latch. 2. Using a hand held plasma cutter or by conventional methods, cut the hole for the frame. 3. Open the door and place the frame into the hole you cut in step 2. 4. Bend over all of the dovetails on the frame with a hammer to ensure a tight fit. DUCTMATE • Advanced Pressure Vessel Design • Insulated, Uninsulated, and Specialty Metals • No Measuring (Self-Adhesive Template Provided) • Effortless Opening and Closing (No Tools Required) • Shape Provides a More Effective Access Area • No Frame to Install Quick and Easy Sandwich® Access Doors Access Doors Rectangular DESCRIPTION Access door for rectangular duct. To provide easy access into air ducts and units. The door was developed to provide a solid, well-insulated, leakproof door that is simple to install. BASIC USE • Insulated or uninsulated• Smooth interior finish on insulated doors• Tested to 20” W.G. with no leakage noted• Tested to negative 10” W.G. with no leakage noted• Please specify when ordering doors for negative pressure applications as gasket is placed to the outside panel• Insulated doors are recommended for negative pressure applications SPECIAL CHARACTERISTICS a. Panels The insulated Sandwich Access Door consists of three layers of precision stamped steel. The inside panel consists of two layers of metal which are spot welded together along the rim encapsulating high density fiberglass insulation with Ecose® Technology UL classified FHC25/50. Uninsulated doors have similar construction without the backing plate and insulation. NOTE: The 24” x 18” door consists of only two layers of precision stamped steel. A polyester foam pad installed between the inner and outer door panels provides insulation. (The 24”x18” door is not available with high density fiberglass insulation). b. Gasket Closed cell neoprene gasket is UL94HF1 listed with a service temperature range of (ASTM D746) -20° F to 200° F. The gasket is bonded to the inside panel of the access door to insure consistent installations. c. Springs Zinc plated conical springs are installed, between the inner and outer door, to facilitate opening. d. Knobs Red polypropylene molded knobs have threaded metal inserts to eliminate thread stripping. Knobs are easily turned by hand. Knobs are UL94HB listed. e. Bolts Zinc plated carriage bolts are secured to inner door. f. Template Self adhesive template is provided for the exact size of duct opening required. TECHNICAL INFORMATION Hi-Temp DESCRIPTION Access door for round or rectangular duct. BASIC USE To provide easy access into grease duct or high-temp duct systems. The door was developed to provide a solid, leak resistant door that is simple to install. High-Temp access door application approval resides with the authority having jurisdiction. SPECIAL CHARACTERISTICS • Available in all sizes of standard flat and round duct access doors • 16 gauge black iron backing plate TECHNICAL INFORMATION a. Panels The Hi-Temp Access Door consists of two layers of precision stamped, hot-dipped galvanized steel and one 16 gauge black iron backing plate. The backing plate is spot welded to the inside panel. b. Gasket For Hi-Temperature application fiberglass rope (1000°F max) is permanently bonded to the outside panel of the access door to eliminate leakage. For Grease Duct application, Ceramic Fiber Gasket (2300°F max -- meets NFPA 96 standards) is permanently bonded to the outside panel of the access door to eliminate leakage. c. Springs Zinc plated conical springs are installed, between the inner and outer door, to facilitate opening. d. Wing Nuts Zinc coated wing nuts are easily turned by hand. e. Bolts Zinc plated carriage bolts are secured to inner door. f. Template Self adhesive template is provided for the exact size of duct opening required. Circular Clean-Out Clean-Out DESCRIPTION Access door for duct cleaning. BASIC USE To provide easy access into air ducts and units. The door was developed to provide a solid, leakproof door that is simple to install. SPECIAL CHARACTERISTICS • Insulated or Uninsulated TECHNICAL INFORMATION a. Panels The Circular Access door consists of two layers of precision stamped, hot-dipped galvanized steel. b. Gasket Closed cell neoprene gasket is UL94HF1 listed with a service temperature range of (ASTM D746) -20° F to 200° F. The gasket is permanently bonded to outside panel of the access door to eliminate leakage. c. Springs Zinc plated conical springs are installed over the bolts, between the inner and outer door, to facilitate opening d. Wing Nuts Zinc coated wing nuts are easily turned by hand without tools. e. Bolts Zinc plated carriage bolts are secured to inner door. f. Insulation A polyester foam pad installed between the inner and outer panel. DESCRIPTION Uninsulated access door for duct cleaning. BASIC USE To provide easy access into air ducts and units. SPECIAL CHARACTERISTICS • Our lowest cost door TECHNICAL INFORMATION a. Panels The Clean-Out Access door consists of two layers of precision stamped, hot-dipped galvanized steel. b. Gasket Closed cell neoprene gasket is UL94HF1 listed with a service temperature range of (ASTM D746) -20° F to 200° F. The gasket is bonded to the inside of the door to insure consistent installations. c. Springs Zinc plated conical springs are installed, between the inner and outer door, to facilitate opening. d. Wing Nuts Zinc coated wing nuts are easily turned by hand. e. Bolts Zinc plated carriage bolts are secured to inner door. f. Template Self adhesive template is provided for the exact size of duct opening required. Round Duct Observation DESCRIPTION Access door for round ducts. BASIC USE To provide easy access into air ducts and units. The door was developed to provide a solid, leak proof door that is simple to install. SPECIAL CHARACTERISTICS • Insulated or uninsulated• Smooth interior finish on insulated doors• Tested to 20” W.G. with no leakage noted• Tested to negative 10” W.G. with no leakage noted• Please specify when ordering doors for negative pressure applications as gasket is placed to the outside panel• Insulated doors are recommended for negative pressure applications TECHNICAL INFORMATION a. Panels The insulated Round Duct Access Door consists of three layers of precision stamped steel. The inside panel consists of two layers of metal which are spot- welded together along the rim, en capsulating high density fiberglass insulation with Ecose® Technology UL classified FHC 25/50 Uninsulated doors have similar construction without the backing plate and insulation. NOTE: The 24” x 18” access door consists of only two layers of pre cision stamped steel. A polyester foam pad installed between the inner and outer door panels provides insulation. (The 24” x 18” door is not available with high density fiberglass insulation). b. Gasket Closed cell neoprene gasket is UL94HF1 listed with a service temperature range of (ASTM D746) -20° F to 200° F. The gasket is bonded to the inside of the door to insure consistent installations. c. Springs Zinc plated conical springs are installed, between the inner and outer door, to facilitate opening. d. Knobs Red polypropylene molded knobs have threaded metal inserts to eliminate thread stripping. Knobs are easily turned by hand. Knobs are UL94HB listed. e. Bolts Zinc plated carriage bolts are secured to inner door. f. Template Self adhesive template is provided for the exact size of duct opening required. DESCRIPTION Access door which allows inspection of the inside of the duct without door removal. BASIC USE To provide easy access into air ducts and unit and allow for viewing the inside of the duct. The door was developed to provide a solid, leakproof door that is simple to install. SPECIAL CHARACTERISTICS • 4” x 2-5/8” viewport• Safety glass used for window• Tested to 10” W.G. TECHNICAL INFORMATION a. Panels The Observation Access Door consists of two layers of precision stamped, hot-dipped galvanized steel. b. Gasket Closed cell neoprene gasket is UL94HF1 listed with a service temperature range of (ASTM D746) -20° F to 200° F. The gasket is permanently bonded to the inside panel to eliminate leakage. c. Springs Zinc plated conical springs are installed, between the inner and outer door, to facilitate opening. d. Knobs Red polypropylene molded knobs have threaded metal inserts to eliminate thread stripping. Knobs are easily turned by hand. Knobs are UL94HB listed. e. Bolts Zinc plated carriage bolts are secured to inner door. f. Glass Safety glass (1/4”) is permanently sealed with silicone. g. Clips Hot-dipped galvanized steel clips mechanically fasten the safety glass in place. h. Template Self adhesive template is provided for the exact size of duct opening required. 1. Peel backing off template and apply to duct in desired location. 2. Opening can be cut with hand-held plasma cutter or by conventional methods. 3. Insert door into opening at an angle and tighten knobs. 4. Do not overtighten knobs or wing nuts. Size Part No. Gauge # Per Carton Lbs Per Carton **8” x 4” D*84GA 22 10 12 10” x 6” D*106GA 22 10 25 12” x 8” D*128GA 22 10 35 **16” x 12” D*1612GA 20 5 31 18” x 14” D*1814GA 20 5 45 **24” x 18” D*2418GA 18 3 27 * Available in Insulated (I) or Uninsulated (U), please specify ** Oval Shaped Rectangular Size Part No. Gauge No. Per Carton Lbs. Per Carton 8” DC*8GA 24 10 12 10” DC*10GA 24 10 17 12” DC*12GA 22 10 26 * Available in Insulated (I) or Uninsulated (U), please specify Circular Clean-Out Size Part No. Gauge No. Per Carton Lbs. Per Carton 10” x 6” DC106GA 24 10 15 12” x 8” DC128GA 24 10 23 Clean-Out Size Part No. Gauge No. Per Carton Lbs. Per Carton 10” x 6” DO106GA 22 10 25 Note: For information on our larger 16” x 12” Observation Door see our stand-alone literature. Observation Door Size Duct Diameter Part Number 8” x 4” 22 Gauge 10 per carton 12 lbs. per carton 5” - 6” 7” - 9” 10” - 11” 12” - 14” DR*846GA DR*849GA DR*8411GA DR*8414GA 12” x 8” 22 Gauge 10 per carton 35 lbs. per carton 10” - 11” 12” - 14” 15” - 16” 17” - 18” 19” - 20” DR*12811GA DR*12814GA DR*12816GA DR*12818GA DR*12820GA 16” x 12” 20 Gauge 5 per carton 31 lbs. per carton 15” - 16” 17” - 18” 19” - 20” 21” - 22” 23” - 24” 25” - 28” 29” - 32” 33” - 36” 37” - 60” DR*161216GA DR*161218GA DR*161220GA DR*161222GA DR*161224GA DR*161228GA DR*161232GA DR*161236GA Consult Factory 24” x 18” available in 2 panel only 18 Gauge 2 per carton 25 lbs. per carton 29” - 32” 33” - 36” 37” - 40” 41” - 44” 45”- 48” 49”- 52” 53” - 56” 57” - 62” 63” - 144” DR*241832GA DR*241836GA DR*241840GA DR*241844GA DR*241848GA DR*241852GA DR*241856GA DR*241862GA Consult Factory * Available in Insulated (I) or Uninsulated (U), please specify Round Duct PACKAGING INFORMATION Door Size Duct Diameter Part Number 8” x 4” 22 Gauge 10 per carton 12 lbs. per carton 5” - 6” 7” - 9” 10” - 11” 12” - 14” DR846*GA DR849*GA DR8411*GA DR8414*GA 12” x 8” 22 Gauge 10 per carton 35 lbs. per carton 10” - 11” 12” - 14” 15” - 16” 17” - 18” 19” - 20” DR12811*GA DR12814*GA DR12816*GA DR12818*GA DR12820*GA 16” x 12” 20 Gauge 5 per carton 31 lbs. per carton 15” - 16” 17” - 18” 19” - 20” 21” - 22” 23” - 24” 25” - 28” 29” - 32” 33” - 36” 37” - 60” DR161216*GA DR161218*GA DR161220*GA DR161222*GA DR161224*GA DR161228*GA DR161232*GA DR161236*GA Consult Factory 24” x 18” 18 Gauge 2 per carton 25 lbs. per carton 29” - 32” 33” - 36” 37” - 40” 41” - 44” 45”- 48” 49”- 52” 53” - 56” 57” - 62” 63” - 144” DR241832*GA DR241836*GA DR241840*GA DR241844*GA DR241848*GA DR241852*GA DR241856*GA DR241862*GA Consult Factory * F1 for doors rated to 1000°F. F2 for doors rated to 2300°F. Round Duct Hi - Temp Size Part No. Gauge No. Per Carton Lbs. Per Carton 8” x 4” **D84*GA 22 10 12 10” x 6” D106*GA 22 10 32 12” x 8” D128*GA 22 10 50 16” x 12” **D1612*GA 20 5 31 18” x 14” D1814*GA 20 5 64 **24” x 18” D2418*GA 18 3 57 * F1 for doors rated to 1000°F. F2 for doors rated to 2300°F. ** Oval Shaped Rectangular Duct Hi-Temp INSTALLATION INSTRUCTIONS SUBMITTAL RECORD JOB LOCATION SUBMITTED TO SUBMITTAL PREPARED BY APPROVED BY DATE Submittal Form Neoprene Gasket ® SUGGESTED SPECIFICATIONS $OOÀDQJHGMRLQWVVKDOOEHVHDOHGZLWKJDVNHWLQJFRGHG BBBBBBBBBBBBBBDVVXSSOLHGE\'XUR'\QH&RUSRUDWLRQ DESCRIPTION :KHUHYHUÀDQJHVDUHXVHGLQFRQQHFWLQJSDUWVRIDGXFWV\VWHPWKH SRWHQWLDOIRUDLUOHDNDJHH[LVWV%HVLGHVFRQWULEXWLQJWRHQHUJ\ZDVWH OHDNVFDQDOVRFUHDWHQRLVH6HDOLQJRIGXFWZRUNFDQEHDFFRPSOLVKHGZLWK WKHXVHRIQHRSUHQHJDVNHWZKLFKDGKHUHVWRÀDQJHGVXUIDFHV:KHQWKLV PDWHULDOLVDWWDFKHGWRDÀDQJHZKLFKLVWKHQDVVHPEOHGWRDVHFRQGÀDQJH WKHPDWHULDOLVFRPSUHVVHGDQG¿OOVJDSVDQGLUUHJXODULWLHVFUHDWLQJDVHDO RELATED SMACNA RECOMMENDATIONS* 1.4.1 - Duct Sealing 'XFWVPXVWEHVXI¿FLHQWO\DLUWLJKWWRHQVXUHHFRQRPLFDODQGTXLHW SHUIRUPDQFHRIWKHV\VWHP,WPXVWEHUHFRJQL]HGWKDWDLUWLJKWQHVVLQ GXFWVFDQQRWDQGQHHGQRWEHDEVROXWH DVLWPXVWEHLQDZDWHUSLS- LQJV\VWHP &RGHVQRUPDOO\UHTXLUHWKDWGXFWVEHUHDVRQDEO\DLUWLJKW &RQFHUQVIRUHQHUJ\FRQVHUYDWLRQKXPLGLW\FRQWUROVSDFHWHPSHUDWXUH FRQWUROURRPDLUPRYHPHQWYHQWLODWLRQPDLQWHQDQFHHWFQHFHVVLWDWH UHJXODWLQJOHDNDJHE\SUHVFULSWLYHPHDVXUHVLQFRQVWUXFWLRQVWDQGDUGV /HDNDJHLVODUJHO\DIXQFWLRQRIVWDWLFSUHVVXUHDQGWKHDPRXQWRI OHDNDJHLQDV\VWHPLVVLJQL¿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¿FDWLRQ 7KHGHVLJQHUVKRXOGUHYLHZWKHHVAC Air Duct Leakage Test 0DQXDO IRUHVWLPDWHGDQGSUDFWLFDOOHDNDJHDOORZDQFHV 6HYHQSUHVVXUHFODVVHVH[LVW>LQ 3D LQ 3D LQ 3D LQ 3D LQ 3D LQ 3D DQGLQ ZJ 3D @,IWKHGHVLJQHUGRHVQRWGHVLJQDWHSUHVVXUHFODVVIRU GXFWFRQVWUXFWLRQRQWKHFRQWUDFWGUDZLQJVWKHEDVLVRIFRPSOLDQFH ZLWKWKH60$&1$HVAC Duct Construction StandardsLVDVIROORZV LQZJ 3D IRUDOOGXFWVEHWZHHQWKHVXSSO\IDQDQGYDULDEOH YROXPHFRQWUROER[HVDQGLQZJ 3D IRUDOORWKHUGXFWVRIDQ\ DSSOLFDWLRQ 6RPHVHDODQWVFDQDGYHUVHO\DIIHFWWKHUHOHDVHIXQFWLRQRIEUHDNDZD\ FRQQHFWLRQVWR¿UHGDPSHUVFRQVXOWWKHGDPSHUPDQXIDFWXUHUIRU LQVWDOODWLRQUHVWULFWLRQV FEATURES • ([FHOOHQWUHVLVWDQFHWRRLODQGIXHO • %ODFNFRQWLQXRXVFORVHGFHOOPHGLXPGHQVLW\UXEEHUSURGXFW • 39&1%5&5FORVHGFHOOUXEEHUPDWHULDOPDQXIDFWXUHGLQFRQWLQX- RXVUROOV Table 1-1 Standard Duct Sealing Requirements Seal Class Sealing Requirements Applicable Static Pressure Construction Class A &ODVV$$OO7UDQVYHUVHMRLQWVORQJLWXGL- QDOVHDPVDQGGXFWZDOOSHQHWUDWLRQV LQZJDQGXS 3D %&ODVV%$OO7UDQVYHUVHMRLQWVDQGORQJL- WXGLQDOVHDPVRQO\LQZJ 3D & &ODVV&7UDQVYHUVHMRLQWVRQO\ LQZJ 3D ,QDGGLWLRQWRWKHDERYHDQ\YDULDEOHDLUYROXPHV\VWHPVGXFWRILQ 3D DQG LQZJ 3D FRQVWUXFWLRQFODVVWKDWLVXSVWUHDPRIWKH9$9ER[HVVKDOOPHHW 6HDO&ODVV& *From SMACNA HVAC Duct Construction Standards Metal and Flexible • Third Edition • 2005 ‹'XUR'\QH&RUSRUDWLRQ3ULQWHGLQ86$%2 ®'XUR'\QH(DVW'LYLVLRQ%D\6KRUH1<  )D[ 'XUR'\QH0LGZHVW'LYLVLRQ+DPLOWRQ2+  )D[ 'XUR'\QH:HVW'LYLVLRQ)RQWDQD&$  )D[ 'XUR'\QH&DQDGD/DFKLQH4XHEHF&DQDGD  )D[ ZZZGXURG\QHFRP(PDLOGXURG\QH#GXURG\QHFRP GGGGGGaaaaasssskket A RECOMMENDA 1(235(1( ,7(0 &2'( '(6&5,37,21 /(1*7+  %1 ´[´¶5/  %1 ´[´¶5/  %1 ´[´¶5/  %1 ´[´¶5/  %1 ´[´ ¶5/  %1 ´[´¶5/ MEETS • 8/9$9%99+)DQG+%)OLVWHGIRUÀDPH • $670'$&%JUDGHSURGXFW • $670'7\SH,,*UDGHV$ %&RQGLWLRQ6RIW0HGLXP PDWHULDO TYPICAL PROPERTIES Color:%ODFN Density: NJP Hardness:  &RPSUHVVLRQ'HÀHFWLRQ#SVL &RPSUHVVLRQ6HW#” Water Absorption: <  Fluid Immersion: <  Tear Strength: OEVLQ Tensile Strength: SVLPLQ Elongation: PLQ Flammability:)0966  8/99$+)+%) Temperature Use: ƒ)ƒ)0D[ ƒ)LQWHUPLWWHQW  DESCRIPTION Knauf Insulation Atmosphere Duct Liner is a flexible, mat-faced insulation bonded with ECOSE Technology. It is faced with a tightly bonded mat to give the airstream a smooth, tough surface, resisting damage during installation and operation. The encapsulant edge coating eliminates airstream flaring. ECOSE® TECHNOLOGY ECOSE Technology is a revolutionary binder chemistry that enhances the sustainability of our products. The “binder” is the bond that holds our glass mineral wool product together and gives the product its shape and brown color. ECOSE Technology is a plant-based, sustainable chemistry that replaces the phenol/formaldehyde (PF) binder traditionally used in glass mineral wool products. Products using ECOSE Technology are formaldehyde-free and have reduced global warming potential when compared to our products of the past. APPLICATION Specifically designed as an interior insulation material for sheet metal ducts used in heating, ventilating and air conditioning. Provides an optimum combination of efficient sound absorption, low thermal conductivity and minimal airstream surface friction. PRODUCT FEATURES • Low thermal conductivity • Fire-resistant, non-corrosive, durable and resilient • Tough, tightly bonded mat facing • Excellent sound absorption • Energy conservation • Better temperature control • Lowers operating costs • Greatly reduces noise from fans and mechanical equipment as well as cross-talk and air movement • Withstands damage from normal handling and shop abuse • If necessary, can be cleaned in accordance with NAIMA’s "Cleaning Fibrous Glass Insulated Air Duct Systems Recommended Practices" • Low emitting for indoor air quality consideration • Airstream surface mat facing is treated with an EPA-registered antimicrobial agent to aid in the prevention of fungal and bacterial growth SUSTAINABILITY Knauf Insulation’s products used for thermal insulating purposes recover the energy that it took to make them in just hours or days, depending on the application. Once installed, the product continues to save energy and reduce carbon generation as long as it is in place. Glass mineral wool insulation with ECOSE Technology contains three key ingredients: • Recycled glass content, verified every six months by UL Environment • Sand, one of the world’s most abundant resources • Our green chemistry initiative ECOSE Technology, which is validated to be formaldehyde-free SPECIFICATION COMPLIANCE In U.S. • ASTM C1071; Type I • ASTM G21 and G22 • NFPA 90A and 90B • ASHRAE 62 In Canada • CAN/ULC S102 • CAN/CGSB-51.11-92 INDOOR AIR QUALITY • UL Environment • GREENGUARD certified • GREENGUARD Gold certified • Validated to be formaldehyde-free • Does not contain polybrominated diphenyl ethers (PBDE) such as Penta-BDE, Octa-BDE, or Deca-BDE • EUCEB APPLICATION & SPECIFICATION GUIDELINES Storage • Inside storage is recommended. Fabrication and Application • Fabricate in compliance with the latest edition of "NAIMA's Fibrous Glass Duct Liner Standard." • Liner shall be folded and compressed in the corners of rectangular duct sections or shall be cut and fit to assure lapped, compressed joints. Longitudinal joints in duct liner should not occur except at the corner of ducts. Longitudinal joints in liner shall be coated with adhesive. All damaged areas of the air stream surface shall be repaired with an adhesive which conforms to ASTM C916. • Liner should be adhered to the duct with 90% minimum area coverage of an adhesive which conforms to ASTM C916. • Mechanical fasteners should not compress the insulation more than 1⁄8" (3 mm), and shall be installed perpendicular to the duct surface. All fasteners should comply with the guidelines of NAIMA's "Fibrous Glass Duct Liner Standard and the Mechanical Fastener’s Standard MF-1-1975." • Metal nosings shall be securely installed over transversely oriented liner edges facing the airstream at fan discharge, at access doors and at any interval of lined duct preceded by unlined duct. In addition, where velocities exceed 4,000 ft./min. (20.3 m/sec.), metal nosing shall be used on upstream edges of liner at every transverse joint (See illustration) Limitations • Knauf Insulation Atmosphere Duct Liner with ECOSE Technology should not be used in systems operating at velocities exceeding 6,000 ft./min. (30.5 m/ sec.) or at temperatures above 250° F (121° C). MAINTAINED DUCT SYSTEMS ARE KEY The best way to ensure that an HVAC system, whether bare metal or internally insulated, will continue to provide efficient, quiet air delivery, occupant comfort, and cost-effectiveness is by following a regular system operation and maintenance schedule. This, along with a high-efficiency filtration system, assures protection of both HVAC system components and building occupants. Maintenance procedures include inspection, detection, and remediation of proable sources of airborne contaminants and moisture. CERTIFICATIONS • UL Environment • GREENGUARD • GREENGUARD Gold • Formaldehyde-free • UL/ULC Classified • Declare Red List Free • EUCEB • USGBC LEED GLASS MINERAL WOOL AND MOLD Glass mineral wool insulation will not sustain mold growth. However, mold can grow on almost any material when it becomes wet and contaminated. Carefully inspect any insulation that has been exposed to water. If it shows any sign of mold, it must be discarded. If the material is wet but shows no evidence of mold, it should be dried rapidly and thoroughly. If it shows signs of facing degradation from wetting, it should be replaced. Air handling insulation used in the air stream must be discarded if exposed to water. NOTES The chemical and physical properties of Knauf Insulation Atmosphere™ Duct Liner with ECOSE® Technology represent typical average values determined in accordance with accepted test methods. The data is subject to normal manufacturing and testing variations. The data is supplied as a technical service and is subject to change without notice. References to numerical flame spread ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions. When condensation is permitted to occur between nested Atmosphere Duct Liner and galvanized steel panels, discoloration of the metal may occur. Check with your Knauf Insulation Territory Manager to ensure information is current. Atmosphere™ Duct Liner with ECOSE® Technology Submittal Date _________________ Technical Data Property (Unit) Test Performance Corrosiveness ASTM C665 Does not accelerate corrosion of steel Corrosion ASTM C1617 Pass Maximum Service Temperature ASTM C411 250° F (121° C) Air Velocity ASTM C1071 Max. 6,000 ft./min. (30.5 m/sec.) Tested to 15,000 ft./min. (76.2 m/sec.) Water Vapor Sorption (by weight) ASTM C1104 Less than 3% Mold Growth ASTM C1338, UL 2824, ASTM G21, ASTM G22 Pass Surface Burning Characteristics (flame spread/smoke developed)ASTM E84, UL 723, CAN/ULC S102 25/50 Atmosphere™ Duct Liner with ECOSE® Technology Submittal Sheet Thermal Conductance “C”* and Resistance “R”† (ASTM C177) Mean Temperature 75° F (24° C) Product Conductance “C” Resistance “R” 1.5 PCF (24 kg/m³) 1" (25 mm) 0.24 (1.42) R-4.2 (0.74) 1.5" (38 mm) 0.17 (0.97) R-6.0 (1.06) 2" (51 mm) 0.13 (0.74) R-8.0 (1.41) 2.0 PCF (32 kg/m³) 0.5" (13 mm) 0.48 (2.73) R-2.1 (0.37) 1" (25 mm) 0.24 (1.36) R-4.2 (0.74) 1.5" (38 mm) 0.16 (0.91) R-6.3 (1.11) “C Units”BTU ft2 ∙ hr ∙ ˚F W m2 ∙ ˚C “R Units”ft2 ∙ hr ∙ ˚F BTU m2 ∙ ˚C W *The lower the value, the better the performance. †The higher the value, the better the performance. Atmosphere™ Duct Liner with ECOSE® Technology Submittal Sheet Sound Absorption Coefficients | ASTM C423, Type A Mounting Type Octave Band Center Frequency (cycles/sec.) 125 250 500 1000 2000 4000 NRC 1.5 PCF (24 kg/m³) 1" (25 mm) 0.18 0.28 0.73 0.85 0.91 0.90 0.70 1.5" (38 mm) 0.23 0.50 0.87 0.92 0.93 0.93 0.80 2" (51 mm) 0.37 0.76 1.02 1.00 0.98 0.92 0.95 2.0 PCF (32 kg/m³) 0.5" (13 mm) 0.10 0.17 0.43 0.59 0.73 0.75 0.50 1" (25 mm) 0.25 0.35 0.69 0.89 0.96 1.01 0.70 1.5" (38 mm) 0.27 0.55 0.87 0.99 1.00 0.98 0.85 Coefficients determined per ASTM E795 Type A Mounting. NOTE: ASHRAE Handbook for HVAC Applications – Sound and Vibration Control contains insertion loss values for lined sheet metal ducts. Forms Available Density Thickness** Width Length 1.5 PCF 1" 34"–36"* (864 mm–915 mm) 46"–48" (1168 mm–1219 mm) 56"–72" (1422 mm–1829 mm) 50' (15.24 m) 100' (30.48 m) 140' (42.67 m) 200' (60.96 m) 1.5" 50' (15.24 m) 90' (27.43 m) 2" 50' (15.24 m) 100' (30.48 m) 2.0 PCF 0.5"100' (30.48 m) 1” 50' (15.24 m) 100' (30.48 m) *Widths of 34"–36" not available with edge coating. **Non-standard widths for all 0.5", 1", 1.5", and 2" products from 34"–36", 46"–48" and 56"–72" are available in 25" (6.35 mm) increments of minimum order quantity. Sales (800) 825-4434 ext. 8485 | Technical Support (800) 825-4434 ext. 8727 | info.us@knaufinsulation.com One Knauf Drive, Shelbyville, IN 46176 | © 2017 Knauf Insulation, Inc. | CI-DLA-SS | 10-17 | www.knaufinsulation.us This product is covered by one or more U.S. and/or other patents. See patent www.knaufinsulation.us/patents. Friction Loss | Inches of water per 100' 100 (HD=Hydraulic Diameter) 100001000 f (in. of H2O per 100 ft.)10.000 1.000 0.100 0.010 0.001 Velocity (ft./min.) Ft./min. Hydraulic Diameter Velocity 10" 16" 24" 32" 40" 72" 100" 500 0.054 0.030 0.018 0.012 0.009 0.005 0.003 600 0.077 0.042 0.025 0.018 0.013 0.007 0.004 700 0.104 0.057 0.034 0.024 0.018 0.009 0.006 800 0.134 0.074 0.044 0.031 0.023 0.011 0.008 900 0.169 0.093 0.056 0.039 0.029 0.014 0.010 1000 0.207 0.114 0.068 0.048 0.036 0.018 0.012 2000 0.806 0.443 0.266 0.186 0.141 0.069 0.046 3000 1.797 0.988 0.594 0.415 0.315 0.153 0.103 4000 3.179 1.748 1.050 0.734 0.557 0.271 0.181 5000 4.952 2.724 1.636 1.143 0.867 0.422 0.283 Mechanical Fastener Location Velocity per ft./min. (m/sec.) 0-2500 (0-12.7) 2501-5000 (12.7-25.4) A. From corners of duct 4" (102 mm) 4" (102 mm) B. From transverse end of duct liner 3" (76 mm) 3" (76 mm) C. Across width of duct, on centers (min. 1/side)12" (305 mm) 12" (305 mm) D. Across length of duct, on centers (min. 1/side)18" (457 mm) 18" (457 mm) NOMINALINSULATIONTHICKNESS AIR FLOW LAPPED AND BUTTED CORNER C (TYP) A A D (TYP) D (TYP) ALL TRANSVERSE EDGES COATED, AT FACTORY OR SHOP APPLIED FOLDED CORNER B B C (TYP) 1⁄8" MAX(3.18mm) Liner Interior Width No. Pins Inches (mm) 0 ≤ 8 ≤ 203 2 9-16 229-406 3 17-28 432-711 4 29-40 737-1016 5 41-52 1041-1321 6 53-64 1346-1626 7 65-76 1651-1930 8 77-88 1956-2235 9 89-100 2261-2540 Atmosphere™ Duct Liner with ECOSE® Technology Submittal Sheet PRODUCT DATA SHEET / SUBMITTAL Discs, Bars & U-Channels Rossi products adhere to all UL requirements, Plenum ratings and SMACNA standards for manual dampers; and comply with NFPA 90A & 90B. Duct fabricators often cut discs out of metal and go through a time consuming process simply to attach the disc to a bar. This involves drilling holes and using u-bolts. That was until Rossi introduced the first discs with a built-in channel for the bar to pass through. Our pre die cut and formed damper discs (blades) save significant manufacturing time and labor, assure consumer confidence in product uniformity, and provide an unparalleled system for quick assembly of dampers. And Rossi discs (or blades) are the only ones designed to be stackable. One hundred and fifty Rossi damper discs stacked together come to less than 10” high, significantly reducing inventory space. And for fabricators who want to cut their own discs out of scrap metal, they can use Rossi’s U-Channels to affix their discs to the bar thereby still using Rossi’s bearings and handles. 1) DAMPER DISCS (or Blades) MATERIAL: G90 Galvanized (ASTM-A527 LFO). Available in 4” to 16” diameter. 4”-14” blades are 22 Gauge. 16” blades are 20 Gauge. A 3/8” full length bar fits through the formed channel in the center of each damper blade. 2) BARS (or Shafts) MATERIAL: 3/8” square Aluminum bar (or shaft). 3) U-Channels MATERIAL: G90 Galvanized (ASTM-A527 LFO). Available to fit 3/8” square Aluminum bar (or shaft). Proudly made in the USA. 2