Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
IC-PAP PRODUCT DATA 072 - APP W NOTATIONS
SUBMITTAL COVER SHEET JOB: ITHACA COLLEGE PHYSICIAN’S ASSISTANT ROTHSCHILD RENOVATION SUBMITTAL NUMBER: 72 DATE: 25 MARCH 2021 SUBCONTRACTOR NAME: ARCHITECTURAL CONCRETE PLUS, LLC ARCHITECTURAL CONCRETE PLUS, LLC 69 HOLLISTER STREET DUNDEE, NY 14837 PHONE: 607-243-7113 FAX 315-423-0054 ACP PROJECT NO: 21-105 ARCHITECT: QPK 450 S SALINA ST STE 500, SYRACUSE, NY 13202 ARCHITECT PROJECT NO: 220157.00 (12/18/2020) TYPE OF SUBMITTAL: X PRODUCT DATA TEST REPORT SHOP DRAWING RECORD DOCUMENT SAMPLE CERTIFICATION MFGR COMPLIANCE CE CLOSEOUT DOCUMENT COLOR SELECTION MFGR DWG SUBSTITUTION MSDS SUBMITTAL DESCRIPTION 283100 FIRE ALARM & DETECTION SUPPLIER ABJ MANUFACTURER VARIOUS SPEC SECTION NUMBER & TITLE SUB-PARAGRAPH DRAWING NO 1ST TIME SUBMISSION X REVISION PRIME CONTRACTOR’S STAMP/CERTIFICATION : I HEREBY CERTIFY THAT I HAVE REVIEWED THIS SUBMITTAL, VERIFIED THE PRODUCTS, VERIFIED FIELD MEASUREMENTS WHERE APPROPRIATE AND HAVE COORDINATED THE INFORMATION WITHIN THE SUBMITTAL WITH THE REQUIREMENTS OF CONTRACT DOCUMENTS. THE SUBMITTED ITEMS COMPLY IN EVERY RESPECT WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS AND SPECIFICATIONS ARCHITECT/ENGINEER REVIEW STAMP: PRIME CONTRACTOR/CONTRACT/BID PKG NO. SIGNED: POSITION: DATE: COMMENTS: 5HFHLYHG0&( X 3-29-21 SDM Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Bulletin 040 Rev. ABulletin 040 Rev. A Model G5-56 300 Quick Response Concealed Automatic 300 psi (20,7 bar) Rated Sprinkler The G5-56 300 Concealer® A Quick Response Concealed Sprinkler with ¾” (19mm) Adjustment For adjustable K5.6 sprinklers refer to Bulletin 162 for Technical Specifications and Approvals Features 1. Cover plate attachment (Plain or Perforated) with ¾” (19mm) total adjustment. Does not require clips or springs. 2. Smooth aesthetic ceiling profile. 3. Factory installed protective cap. 4. Available in chrome and white painted finishes. 5. Ordinary and intermediate temperature rating. 6. 300 psi (20,7 bar) maximum pressure rating. Listings & Approvals 1. Listed by Underwriters Laboratories, Inc. and Certified by UL for Canada (cULus) - Quick Response Note: Approvals are for light and ordinary hazard. The cup and skirt are fabricated from plated steel and are recommended for interior, non-corrosive applications. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. US. Patent Number 6,554,077 The Model G5-56 300 Concealer® is a cULus Listed Quick Response Concealed Sprinkler intended for use in accor- dance with NFPA 13. Product Description The Reliable Model G5-56 300 Concealer® uses a proven quick response fusible element in a standard style sprin- kler frame with a drop-down deflector. This assembly is re- cessed into the ceiling and concealed by a flat cover plate assembly. This threaded engagement provides ¾” (19mm) of cover adjustment. The flat cover plate is attached to the skirt using 135°F (57°C) ordinary temperature classification solder or 165°F (74°C) intermediate temperature classifica- tion solder. When the ceiling temperature rises, the solder holding the flat cover plate melts, the flat cover plate re- leased thus exposing the sprinkler inside to the rising ambi- ent temperature. The subsequent fusing of the solder element in the sprin- kler opens the waterway and causes the deflector to drop into position to distribute the discharging water. Any secure engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. Application The Reliable Model G5-56 300 Concealer® is a versatile quick response concealed sprin- kler. It provides the best form of fire protection while offering an attractive appearance and ¾” (19mm) cover plate adjust- ment for ease of installation. The small diameter cover plate as- sembly is easily attached and Plain Cover Plate Perforated Cover Plate blends into the ceiling, concealing the most dependable fire protection, an automatic sprinkler system. The Model G5-56 300 Concealer® is designed for use where aesthetic appearance is important. It can be used at working pressures up to 300 psi (20,7 bar). Installation Do not install the G5-56 300 in ceilings which have pos- itive pressure in the space above. • Cut a 25/8” inch (67mm) diameter hole in the ceiling, the sprinkler is easily installed with the Model FC Wrench. The wrench has a socket drive which is in- serted into the body of the sprinkler. When installing a sprinkler the wrench is first positioned into the sprin- kler/cup assembly until the wrench socket engages the body of the sprinkler. The sprinkler is then tight- ened into the pipe fitting. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. Install the cover plate by hand turning the cover in the clockwise direction until it is tight against the ceiling. A protective cap is provided to protect the drop-down sprinkler deflector from damage which could occur dur- ing construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then re-install cap until the cover plate is installed. Maintenance The Model G5-56 300 Concealer® should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler that has been painted (other than factory ap- plied) or damaged in any way. A stock of spare sprin- klers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper opera- tion or non-operation. Ordering Information Specify: 1. Sprinkler Model 2. Nominal Orifice 3. Flat Cover Plate Assembly Finish UL Listing Category Sprinklers, Automatic and Open Quick Response Sprinkler UL Guide Number VNIV Cover Plate Finishes(1) Standard Finishes Chrome White Paint Special Application Finishes(2)(3) Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome (1) Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi-gloss, unless specified otherwise. (2) For the perforated style coverplate, consult factory for availability on these and other custom finishes. (3) Available upon request. Standard Temperature Ratings ClassiÀ cation Sprinkler Link Color Cover Plate Max. Ambient Temp. Ordinary 165°F/74°C Black 135°F/57°C 100°F/38°C Intermediate 212°F/100°C White 165°F/74°C 150°F/66°C Model FC Sprinkler Wrench 2. Technical Data Sprinkler Inlet Total Adjustment Nominal OriÀ ce Nominal K Factor Thread Approvals Sprinkler IdentiÀ cation Number (SIN)US Metric Non Adjustable ¾” (19mm) ½” (15mm) 5.6 80 ½” NPT (R½) 1 RA4014 Notice FOR USE AS A REPLACEMENT OF MODEL G4A-300 SPRINKLERS NOTE: 1. Testing has shown that use of a “nipple extension” will not affect the listing of the sprinkler. 2. For RETROFIT installations, per NFPA 13 (2010) section 8.15.19.4, “which allows the use of nipples as the same pipe thread size as the existing outlet when revamping existing systems”. 3. Do not exceed 8-18 ft-lbs of torque during installation. 3. Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax(914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by RecycledPaper Revision lines indicate updated or new data. EG. Printed in U.S.A. 11/14 P/N 9999970431 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F1FR Series Quick Response Glass Bulb Sprinklers Bulletin 014 Rev. M Bulletin 014 Rev. M Model F1FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model F1FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model F1FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1FR42, F1FRXLH & F1FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model F1FR40 Sprinkler Types Standard Spray Pendent Model F1FR42, F1FR40, F1FRXLH & F1FR28 Recessed Sprinkler Types Standard Spray Pendent Model F1FR56LL & F1FR42LL NSF CertiÀ ed Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model F1FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. 1. Underwriters Laboratories Inc. and Certified for Canada (cULus). 2. FM Approvals (FM) 3. Loss Prevention Certification Board (LPCB) 4. Vertrauen durch Sicherheit (VdS) 5. NSF Certified to NSF/ANSi Standard 61 Annex G (NSF) 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) (EC) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Pendent Conventional Recessed Pendent/F1/F2 Upright Vertical Sidewall Horizontal Sidewall Recessed Horizontal Sidewall RecessedPendent/FP Concealed Pendent XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 XLH Recessed Pendent FP Product Description Reliable Model F1FR series sprinklers are quick-response automatic sprin- klers with a glass bulb thermal element. Model F1FR series sprinklers are Stan- dard Spray sprinklers, with the excep- tion of the Model F1FR56 Conventional sprinkler which is an Old-style/Conven- tional sprinkler. The Model F1FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. 2. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model F1FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used:• Pendent, recessed pendent, upright, horizontal side- wall, and vertical sidewall deÁ ectors• K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric)• Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model F1FR series sprinkler configurations. Model F1FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model F1, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1FR series sprinkler. Model F1 and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model F1FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model F1FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model RC1 wrench is used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. 3. Design and Installation Information Model Nominal K-factor Nominal OriÀ ce Diameter DeÁ ector/ Orientation Nominal Sprinkler Height Installation Wrench SIN Listings and Approvals Approval Notes US Metric inches mm inches mm F1FR28 2.8 40 3/8 10 Pendent 2.25 57 D RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 D RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 D RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS F1FR42 4.2 60 7/16 10 Pendent 2.25 57 D RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 D RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 D RA1410 cULus, NSF Recessed Pendent 2.25 57 GFR2 RA1410 cULus, NSF F1FRXLH (F1FR42 with Pintle) 4.2 60 7/16 10 Pendent 2.25 57 D RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 D RA1423 cULus 1,2 F1FR56 5.6 80 1/2 15 Pendent 2.25 57 D RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 D RA1425 cULus, FM, LPCB, VdS, EC 1,2,3,4 "Conventional (Pendent or Upright)"2.25 57 D RA1475 LPCB, VdS, EC 4 F1FR56LL 5.6 80 1/2 15 Pendent 2.25 57 D RA1415 cULus, NSF 1 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, NSF Concealed Pendent 2.25 57 RC1 RA1414 cULus, NSF 6 F1FR56 5.6 80 1/2 15 Horizontal Sidewall 2.63 67 D RA1435 cULus, FM 1,2,3,7 Recessed Horizontal Sidewall 2.63 67 GFR2 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright)2.25 57 D RA1485 cULus, FM, LPCB 1,2,3,9 (1) cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (2) cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (3) Available with FM approved Polyester coating in black or white. (4) Available with LPCB and VdS approved Polyester coating. (5) VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. (6) Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. (7) cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the F1FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. (8) cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (9) The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches (102mm to 305mm). LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) F1FR56 5.6 80 1/2 15 Upright 2.25 57 D RA1425 cULus, FM, LPCB, VdS, EC 1,2,3,4 F1FR56 5.6 80 1/2 15 Recessed Horizontal Sidewall 2.63 67 GFR2 RA1435 cULus, FM 8 4. Listed and Approved Temperature Ratings Model DeÁ ector/ Orientation Ordinary Temp. ClassiÀ cation 100°F (38°C) Max. Ambient Temp. Intermediate Temp. ClassiÀ cation 150°F (65°C) Max. Ambient Temp. High Temp. ClassiÀ cation 225°F (107°C) Max. Ambient Temp. 135°F (57°C) Temp. Rating 155°F (68°C) Temp. Rating 175°F (79°C) Temp. Rating 200°F (93°C) Temp. Rating 286°F (141°C) Temp. Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb F1FR28 Pendent cULus Recessed Pendent cULus -- Upright cULus F1FR40 Pendent VdS Recessed Pendent VdS -- F1FR42 Pendent cULus Recessed Pendent cULus -- Upright cULus F1FR42LL Pendent -- cULus, NSF -- Recessed Pendent -- cULus, NSF -- F1FRXLH Pendent cULus Recessed Pendent cULus -- Upright cULus F1FR56 Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC -- Concealed Pendent* cULus cULus,VdS,EC cULus -- Upright cULus, FM, LPCB, VdS, EC “Conventional (Pendent or Upright)”LPCB, VdS, EC F1FR56LL Pendent -- cULus, NSF -- Recessed Pendent -- cULus, NSF -- Concealed Pendent* -- cULus, NSF -- F1FR56 Horizontal Sidewall cULus, FM Recessed Horizontal Sidewall cULus, FM -- F1FR56 Vertical Sidewall (Pen- dent or Upright)cULus, FM, LPCB * Model F1FR56 Concealed Pendent and F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Model DeÁ ector/ Orientation Listed and Approved Recessed Escutcheons SIN Model F1 (Fig. 1 & 3) 3/4-inch (19mm) adjustment Model F2 (Fig. 1 & 3) 1/2-inch (12.7mm) adjustment Model FP (Fig. 2) 1/2-inch (12.7mm) adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, EC cULus, FM, LPCB, VdS, EC cULus, VdS, EC RA1414 F1FR56LL Recessed Pendent cULus, NSF cULus, NSF cULus, NSF RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 5. Fig. 1 Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon Fig. 2 Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model FP escutcheon 6. Fig. 3 Model F1FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 escutcheon Fig. 4 Model F1FR56/F1FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plate 7. Fig. 5 - Model F1FR56/F1FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.0mm) adjustment - Model CCP cover plate Maintenance The Model F1FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate (1) Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (4)(5)(6)White Painted Special Application Finishes Sprinkler Escutcheon Cover plate (1) Electroless Nickel PTFE(7) Electroless Nickel PTFE Bright Brass Bright Brass(3)Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint(2)(6)Black Paint Off White Off White(2)(6) Off White Satin Chrome Chrome Dull Chrome Dull (1) Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. (2) cULus Listed only. (3) 200°F (93°C) maximum. (4) cULus listed “corrosion resistance” applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. (5) FM Approvals finish as “Polyester coated” applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. (6) LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. (7) cULus listed Corrosion Resistant Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass DeÁ ector:CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup:CDA Alloy 651 or 693 Washer:Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb:Glass Ordering Information Specify: 1. Sprinkler Model: [F1FR28][F1FR40][F1FR42] [F1FR42LL][F1FRXLH][F1FR56][F1FR56LL] 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent][Upright][Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] 4. Sprinkler Temperature Rating: [135°F (57°C)][155°F (68°C)][175°F (79°C)][200°F (93°C)][286°F (141°C)] 5. Sprinkler Finish 6. Escutcheon Model: [F1][F2][FP] 7. Escutcheon Finish (where applicable) 8. Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.0mm) adjustment] 9. Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] 10. Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by RecycledPaper Revision lines indicate updated or new data. EG. Printed in U.S.A. 06 /15 P/N 9999970300 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection Schedule 10 and Schedule 40 NPS NOM OD NOM ID NOMINAL WALL NOMINAL WEIGHT UL PIECES in. mm in. mm in. mm lbs./ft. kg/m CRR* Lift 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 1 ¼1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 1 ½1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. * The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). SCHEDULE 40 SPECIFICATIONS Proprietary mill coating ensures clean, corrosion- resistant surface Outperforms and outlasts standard lacquer-coated pipe Easily painted, without special preparation Available with hot-dip galvanizing Also available in black Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe are subjected to the toughest possible testing to ensure the highest possible quality—not to mention reliable, long-lasting performance. High quality, high performance Schedule 10 and Schedule 40 Meet or Exceed These Standards: • UL, C-UL and FM Listed • FM Approved • ASTM A135, Type E, Grade A (Schedule 10) • ASTM A53, Type E, Grade B (Schedule 40 5–6) • ASTM A795, Type E, Grade A (Schedule 40) • NFPA 13 NOMINAL SIZE OD SCHEDULE 40 in.Wall Inches Wt. lbs./ft. Wt./Ft. H2O Filled 1 1.315 .133 1.68 2.055 1 ¼1.660 .140 2.27 2.922 1 ½1.900 .145 2.72 3.602 2 2.375 .154 3.66 5.109 2 ½2.875 .203 5.80 7.871 3 3.500 .216 7.58 10.783 3 ½4.000 .226 9.12 — 4 4.500 .237 10.80 16.311 5 5.563 .258 14.63 23.262 6 6.625 .280 18.99 31.498 NPS NOM ID WT./FT. LBS. WT./FT. H20 FILLED PCS./LIFT WT./LIFT 21' WT./LIFT 24' WT./LIFT 25' 1 ¼1.442 1.807 2.514 61 2315 2645 2756 1 ½1.682 2.087 3.049 61 2673 3055 3183 2 2.157 2.640 4.222 37 2051 2344 2442 2 ½2.635 3.534 5.895 30 2226 2544 2651 3 3.260 4.336 7.949 19 1730 1977 2060 4 4.260 5.619 11.789 19 2242 2562 2669 5 5.295 7.780 17.309 13 2124 2427 2529 6 6.357 9.298 23.038 10 1953 2232 2325 8 8.249 16.96 40.086 7 2493 2849 2968 TECHNICAL DATA CHART WEIGHTS AND DIMENSIONS CHART NPS NOM OD NOM ID NOMINAL WALL NOMINAL WEIGHT UL PIECES in. mm in. mm in. mm lbs./ft. kg/m CRR* Lift 1 ¼1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 1 ½1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 2 ½2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 4 4.500 114.3 4.260 108.2 .120 3.05 5.62 8.37 1.6 19 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 6 6.625 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 * Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. * The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). SCHEDULE 10 SPECIFICATIONS GRINNELL G-FIRE Figure 577 Grooved Rigid Coupling 1 to 12 Inch (DN25 to DN300) Page 1 of 4 NOVEMBER 2014 TFP1854 Worldwide Contacts www.tyco-fire.com General Description The GRINNELL G-FIRE Figure 577 Grooved Rigid Couplings provide a rigid joint by firmly gripping along the full circumference of the pipe grooves. Figure 577 couplings are a proven de- pendable method of joining pipe and are an economical alternative to weld- ing, threading, or using flanges. Figure 577 couplings are rated at pressures up to 350 psi (24, 1 bar) de- pending on pipe size and wall thick- ness when used in fire protection ser- vice applications. Refer to Table A. NOTICE The GRINNELL G-FIRE Figure 577 Grooved Rigid Coupling described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the Approval agency, in addition to the standards of any other authorities having jurisdiction. Failure to do so may result in serious person- al injury or impair the performance of these devices. Never remove any piping component nor correct or modify any piping de- ficiencies without first de-pressurizing and draining the system. Failure to do so may result in serious personal inju- ry, property damage, and/or impaired device performance. It is the designer’s responsibility to se- lect products suitable for the intend- ed service and to ensure that pressure ratings and performance data are not exceeded. Material and gasket selec- tion should be verified to be compati- ble for the specific application. Always read and understand the installation instructions. The owner is responsible for maintain- ing their mechanical system and de- vices in proper operating condition. The installing contractor or device manufacturer should be contacted with any questions. Technical Data Approvals UL and ULC Listed FM Approved VdS Approved LPCB (Cert. Nos. 669a and 673a) Refer to Table A for details. Sizes 1 to 12 Inch (DN25 to DN300) Housing Ductile iron conforming to ASTM A536, Grade 65-45-12 Finish r 0SBOHFOPOMFBEQBJOU r 3FEOPOMFBEQBJOU r)PUEJQQFE (BMWBOJ[FEDPOGPSNJOH UP"45." Bolts/Nuts r "/4* $BSCPO4UFFMPWBMOFDLUSBDLIFBE CPMUTBSFIFBUUSFBUFEBOEDPOGPSN UPUIFQIZTJDBMQSPQFSUJFTPG"45. "(SBEFBOE4"&+(SBEF XJUIBNJOJNVNUFOTJMFTUSFOHUIPG QTJ Carbon Steel heavy hex nuts con- form to the physical properties of ASTM A183 Grade 2 and SAE J995 Grade 5. Bolts and nuts are zinc- electroplated conforming to ASTM B633. Stainless Steel bolts and nuts are available upon request. r.FUSJD: $BSCPO4UFFMPWBMOFDLUSBDLIFBE CPMUT (PMEDPMPSDPEFE BSFIFBU USFBUFEBOEDPOGPSNUPUIFQIZTJDBM QSPQFSUJFTPG"45.'.XJUIB NJOJNVN UFOTJMF TUSFOHUI PG .1B Carbon Steel heavy hex nuts con- form to the physical properties of ASTM A563M Class 9. Bolts and nuts are zinc-electroplated con- forming to ASTM B633. Gaskets s Pre-lubricated Grade “A” EPDM, Violet color code, -30°F to 150°F (-34°C to 66°C) For dry and freezer systems, lubri- cation is required. Refer to Installa- tion Manual IH-1000FP for details. s Tri-Seal Grade “E” EPDM, Green color code, -30°F to 230°F (-34°C to 110°C) For proper gasket selection, refer to Technical Data Sheet TFP1895. 'PS'JSF1SPUFDUJPOQSFTTVSFSBUJOH MJTUJOH BOEBQQSPWBMJOGPSNBUJPO DPOUBDU ZPVS5:$03FQSFTFOUBUJWF TFP1854 Page 2 of 4 Pipe Size Max.b Pressures psi (bar) Max.b End Load Lbs. (kN) Max.a, d End Gap Inches (mm) Nominal Dimensions Coupling Bolts Approx. Weight Lbs. (kg) Nominal ANSI Inches DN O.D. Inches (mm) A Inches (mm) B Inches (mm) C Inches (mm) Qty. Sizec Inches (mm) %/ Y .Y %/ Y .Y %/ Y .Y %/ Y .Y %/ Y .Y – %/ — .Y %/ Y .Y %/ Y .Y – %/ — .Y %/ Y .Y – %/ — .Y %/ Y .Y %/ Y .Y e %/ Y .Y e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age 3 of 4 Pipe Sizes Nominal ANSI Inches (O.D. mm) Pipe Schedulec Pressure Rating psi (bar) UL ULC FM a a b Pipe Sizes Nominal ANSI Inches (O.D. mm) Pipe Specificationd Pressure Rating psi (bar) LPCB VdS *40.FEJVN — *408BMM5IJDLOFTT NN — %*/PS— B 'PSBOEJODITJ[FT NJOJNVNBMMPXFEQJQFXBMMUIJDLOFTTJTJODIFT C 'PS*ODI 4DIFEVMFJTNJOJNVNBMMPXFEQJQFXBMMUIJDLOFTTCZ6-BOE6-$JODIXBMMUIJDLOFTTJTUIFNJOJNVNBMMPXFECZ'. D 4FF"HFODZXFCTJUFGPS-JTUJOH"QQSPWBMTPGPUIFSQJQFTQFDJàDBUJPOT 6-XFCTJUFTFF0OMJOF$FSUJàDBUF%JSFDUPSZ XXXVMDPN '.(MPCBMXFCTJUFXXXBQQSPWBMHVJEFDPN E 4FF"HFODZXFCTJUFGPS-JTUJOH"QQSPWBMTPGPUIFSQJQFTQFDJàDBUJPOT -1$#XFCTJUFTFF4FBSDI0VS-JTUJOHT"VUPNBUJD4QSJOLMFST 8BUFS4QSBZBOE%FMVHF4ZTUFNT XXXSFECPPLMJWFDPN 7E4XFCTJUFTFFDFSUJàDBUJPOT XXXWETEF Pipe O.D. mm Pipe Specificationc Pressure Rating psi (bar) UL FM *405ZQF' *405ZQF%BOE& &/)FBWZ &/.FEJVN *405ZQF% & BOE' &/)FBWZ &/.FEJVN &/)FBWZ &/.FEJVN TABLE A LISTED/APPROVED PRESSURE RATINGS GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP1854 Page 4 of 4 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. Care and Maintenance The GRINNELL G-FIRE Figure 577 Grooved Rigid Coupling must be maintained in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys- tem from the proper authorities and notify all personnel who may be af- fected by this decision. After placing a fire protection system in service, notify the proper authorities and advise those responsible for mon- itoring proprietary and/or central sta- tion alarms. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and devic- es in compliance with this document, as well as with the applicable stan- dards of the National Fire Protection Association (e.g., NFPA 25), in addi- tion to the standards of any authority having jurisdiction. Contact the install- ing contractor or product manufac- turer with any questions. Any impair- ments must be immediately corrected. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure GRINNELL Products are available glo- bally through a network of distribution centers. For the nearest distributor, visit www.tyco-fire.com. When plac- ing an order, indicate the full product name. Specify: G-FIRE Figure 577 Grooved Rigid Coupling, quantity, pipe size (Nominal ANSI or O.D.), finish (Or- ange, Red, or Galvanized), and type of gasket: s Pre-lubricated Grade “A” EPDM s Tri-Seal Grade “E” EPDM Page 5 of 6 TFP1810 Figures 391, 392, 393, 312 and 313 Figure 341 E to E Figure 327 C to E C to E Figure 393 E to E Figure 392 E to E Figure 391 E to E Figure 313C to E C to E Figure 341 150 lbs. Flange Adapter C to E Appx. Wt. E to E Appx. Wt. nches Lbs. Inches Lbs. mm kg. mm kg. 2.75 2.0 4.00 2.8 69.6 0.9 101.6 1.3 2.75 2.2 4.00 3.2 69.9 2.0 101.6 1.5 3.25 2.7 4.0 5.2 82.6 1.2 101.6 2.4 3.75 5.0 4.00 8.0 95.3 2.3 101.6 3.6 4.25 7.1 4.00 10.2 108.0 3.2 101.6 4.6 5.00 11.9 6.00 17.2 127.0 5.4 152.4 7.8 5.50 17.1 6.00 21.4 139.7 7.8 152.4 9.7 6.50 27.5 6.00 26.0 165.1 12.5 152.4 11.8 7.75 47.0 6.00 38.4 196.9 21.3 152.4 17.4 9.00 68.0 8.00 65.0 228.6 30.8 203.2 29.5 10.00 107.0 8.00 91.0 254.0 48.5 203.2 41.3 Nominal Size 11/4" 11/2" 2" 21/2" 3" 4" 5" 6" 8" 10" 12" Figure 327 Cross Figures 391, 392 and 393 Adapter Nipples E to E Appx. Wt. C to E Appx. Wt. C to E Appx. Wt. Inches Lbs. Inches Lbs. Inches Lbs. mm Kg. mm Kg. mm Kg. 4.00 0.8 1.75 0.4 1.38 0.4 101.6 0.4 44.5 0.2 35.1 0.2 4.00 0.9 1.75 0.5 1.38 0.5 101.6 0.4 44.5 0.2 35.1 0.2 4.00 1.2 1.88 0.6 1.38 0.6 101.6 0.5 47.8 0.3 35.1 0.3 4.00 1.9 2.00 0.7 1.50 1.1 101.6 0.9 50.8 0.3 38.1 0.5 4.00 2.5 2.25 1.4 1.50 1.2 101.6 1.1 57.2 0.6 38.1 0.5 6.00 5.5 2.63 2.4 1.75 2.2 152.4 2.5 66.8 1.1 44.5 1.0 6.00 7.4 2.88 4.1 2.00 3.3 152.4 3.4 73.2 1.9 50.8 1.5 6.00 9.5 3.13 5.6 2.00 4.6 152.4 4.3 79.5 2.5 50.8 2.1 6.00 14.2 3.88 11.1 2.00 8.7 152.4 6.4 98.6 5.0 50.8 3.9 8.00 27.0 4.38 14.0 2.13 9.1 203.2 12.2 11.3 6.4 54.1 4.1 8.00 33.0 4.88 22.0 2.25 16.7 203.2 15.0 124.0 10.0 57.2 7.6 Nominal Size 11/4" 11/2" 2" 21/2" 3" 4" 5" 6" 8" 10" 12" Figure 312 Figure 313 221/2° Elbow 11 1/4° Elbow Figures 327 and 341 Figure 312 C to E C to E General Notes: It is the Designer’s responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (IH-1000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application.Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. Page 6 of 6 TFP1810 Figure 321 Figure 321 C to E C to E 11⁄2 x 11⁄2 x 11⁄4 6 x 6 x 4 2 x 2 x 11⁄2 6 x 6 x 5 21⁄2 x 21⁄2 x 11⁄4 8 x 8 x 2 21⁄2 x 21⁄2 x 11⁄2 8 x 8 x 3 21⁄2 x 21⁄2 x 2 8 x 8 x 4 3 x 3 x 11⁄2 8 x 8 x 5 3 x 3 x 2 8 x 8 x 6 3 x 3 x 21⁄2 10 x 10 x 2 4 x 4 x 11⁄4 10 x 10 x 3 4 x 4 x 11⁄2 10 x 10 x 4 4 x 4 x 2 10 x 10 x 5 4 x 4 x 21⁄2 10 x 10 x 6 4 x 4 x 3 10 x 10 x 8 5 x 5 x 2 12 x 12 x 3 5 x 5 x 21⁄2 12 x 12 x 4 5 x 5 x 3 12 x 12 x 5 5 x 5 x 4 12 x 12 x 6 6 x 6 x 2 12 x 12 x 8 6 x 6 x 21⁄2 12 x 12 x 10 6 x 6 x 3 Figure 321 Reducing Tee Nominal C to E Appx. Wt. Nominal C to E Appx. Wt. Size Inches Lbs. Size Inches Lbs. Inches mm Kg.Inches mm Kg. 3.25 2.0 6.50 26.6 82.6 0.9 165.1 12.1 3.25 2.7 6.50 27.0 82.6 1.2 165.1 12.2 3.75 4.2 7.75 36.2 95.3 1.9 196.9 16.4 3.75 4.2 7.75 36.5 95.3 1.9 196.9 16.6 3.75 4.3 7.75 36.6 95.3 2.0 196.9 16.6 4.25 5.3 7.75 36.8 108.0 2.4 196.9 16.7 4.25 5.5 7.75 37.0 108.0 2.5 196.9 16.8 4.25 5.8 9.00 57.1 108.0 2.6 228.6 25.9 5.00 9.8 9.00 57.4 127.0 4.4 228.6 26.0 5.00 9.9 9.00 57.6 127.0 4.5 228.6 26.1 5.00 10.1 9.00 57.8 127.0 4.6 228.6 26.2 5.00 10.3 9.00 58.0 127.0 4.7 228.6 26.3 5.00 10.5 9.00 58.4 127.0 4.8 228.6 26.5 5.50 14.5 10.00 80.2 139.7 6.6 254.0 36.4 5.50 14.8 10.00 80.5 139.7 6.7 254.0 36.5 5.50 15.2 10.00 80.7 139.7 6.9 254.0 36.6 5.50 15.8 10.00 80.9 139.7 7.2 254.0 36.7 6.50 26.5 10.00 91.4 165.1 11.9 254.0 41.5 6.50 26.5 10.00 91.8 165.1 12.0 254.0 41.6 6.50 26.5 165.1 12.0 GRINNELL G-FIRE Grooved Fittings, Ductile Iron Worldwide Contacts www.tyco-fire.com Page 1 of 26 JANUARY 2016 TFP1815 For Fire Protection pressure rating, listing and approval information, contact Tyco Fire & Building Products. General Description GRINNELL G-FIRE Grooved Fittings provide an economical and efficient method of changing direction, adding an outlet, reducing, or capping piping systems. The G-FIRE grooved fittings are available in ductile iron or fabri- cated steel as indicated. Note: Figure 510S and 519S fittings are special short radius fittings with smaller center to end dimensions than stan- dard grooved fittings. Depending on the size and coupling used, there may be interferences at the bolt pads that require repositioning of the coupling orientation. The use of flange adapters is not recommended with Figures 510S and 519S fittings. Contact TYCO Fire Protection Products for details. NOTICE Never remove any piping component nor correct or modify any piping defi- ciencies without first de-pressurizing and draining the system. Failure to do so may result in serious personal injury, property damage, and/or impaired device performance. It is the designer’s responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data are not exceeded. Material and gasket selection should be verified to be compatible for the specific applica- tion. Always read and understand the installation instructions. The GRINNELL G-FIRE Grooved Fittings described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the approval agency, in addition to the standards of any other authorities having jurisdiction. Failure to do so may result in serious personal injury or impair the perfor- mance of these devices. The owner is responsible for maintain- ing their system and devices in proper operating condition. Contact the install- ing contractor or product manufacturer with any questions Technical Data Approvals UL and ULC Listed FM Approved VdS Approved LPCB Cert. No. 669a Material Cast: Ductile iron conforming to ASTM A536, Grade 65-45-12 Protective Coatings • Non-lead orange paint (USA) • RAL red or non-lead paint (EMEA and APAC) • Hot dipped galvanized conforming to ASTM A153 Care and Maintenance The following inspection procedure must be performed as indicated, in addition to any specific requirements of the NFPA. Any impairments must be immediately corrected. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this decision. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authority having juris- diction. Contact the installing contrac- tor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. Note - fittings not of domestic manufacture as specified on contract drawings. TFP1815 Page 2 of 26 1. Figure 550 is available for the America market only. Nominal Pipe Size Figure 250 Cast Figure 350 Fabricated Figure 550(1) Cast ANSI Inches (DN) O.D. Inches (mm) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) 1-1/4 x 1 (32 x 25) 1.66 x 1.31 (42,4 x 33,4) 2.50 (63,5) 0.7 (0,3)——2.50 (63,5) 0.7 (0,3) 1-1/2 x 1 (40 x 25) 1.90 x 1.31 (48,3 x 33,4)——2.50 (63,5) 0.7 (0,3)—— 1-1/2 x 1-1/4 (40 x 32) 1.90 x 1.66 (48,3 x 42,4) 2.50 (63,5) 0.8 (0,3)——2.50 (63,5) 0.8 (0,3) 2 x 1 (50 x 25) 2.37 x 1.31 (60,3 x 33,4)——2.50 (63,5) 0.9 (0,4)—— 2 x 1-1/4 (50 x 32) 2.37 x 1.66 (60,3 x 42,4)——2.50 (63,5) 0.9 (0,4)—— 2 x 1-1/2 (50 x 40) 2.37 x 1.90 (60,3 x 48,3)——2.50 (63,5) 1.0 (0,5)—— 2-1/2 x 1 (65 x 25) 2.87 x 1.31 (73,0 x 33,4)——2.50 (63,5) 1.2 (0,5)—— 2-1/2 x 1-1/4 (65 x 32) 2.87 x 1.66 (73,0 x 42,4) 2.50 (63,5) 1.4 (0,6)——2.50 (63,5) 1.4 (0,6) 2-1/2 x 1-1/2 (65 x 40) 2.87 x 1.90 (73,0 x 48,3) 2.50 (63,5) 1.4 (0,6)——2.50 (63,5) 1.4 (0,6) 2-1/2 x 2 (65 x 50) 2.87 x 2.37 (73,0 x 60,3) 2.50 (63,5) 1.3 (0,6)——2.50 (63,5) 1.3 (0,6) 76mm x 1-1/4 (65 x 32) 3.00 x 1.66 (76,1 x 42,4) 2.50 (63,5) 1.4 (0,6)——2.50 (63,5) 1.4 (0,6) 76mm x 1-1/2 (65 x 40) 3.00 x 1.90 (76,1 x 48,3) 2.50 (63,5) 1.4 (0,6)——2.50 (63,5) 1.4 (0,6) 76mm x 2 (65 x 50) 3.00 x 2.37 (76,1 x 60,3) 2.50 (63,5) 1.5 (0,7)——2.50 (63,5) 1.5 (0,7) 3 x 1 (80 x 25) 3.50 x 1.31 (88,9 x 33,4)——2.50 (63,5) 1.3 (0,6)—— 3 x 1-1/4 (80 x 32) 3.50 x 1.66 (88,9 x 42,4)——2.50 (63,5) 1.3 (0,6)—— 3 x 1-1/2 (80 x 40) 3.50 x 1.90 (88,9 x 48,3) 2.50 (63,5) 1.8 (0,8)——2.50 (63,5) 1.8 (0,8) 3 x 2 (80 x 50) 3.50 x 2.37 (88,9 x 60,3) 2.50 (63,5) 1.7 (0,8)——2.50 (63,5) 1.7 (0,8) 3 x 2-1/2 (80 x 65) 3.50 x 2.87 (88,9 x 70,3) 2.50 (63,5) 1.7 (0,8)——2.50 (63,5) 1.7 (0,8) 3 x 76mm (80 x 65) 3.50 x 3.00 (88,9 x 76,1) 2.50 (63,5) 2.0 (0,9)——2.50 (63,5) 2.0 (0,9) 4 x 1 (100 x 25) 4.50 x 1.31 (114,3 x 33,4)——3.00 (76,2) 2.9 (1,1)—— 4 x 1-1/4 (100 x 32) 4.50 x 1.66 (114,3 x 42,4)——3.00 (76,2) 2.2 (1,0)—— 4 x 1-1/2 (100 x 40) 4.50 x 1.90 (114,3 x 48,3)——3.00 (76,2) 2.3 (1,0)—— 4 x 2 (100 x 50) 4.50 x 2.37 (114,3 x 60,3) 3.00 (76,2) 2.4 (1,1)——3.00 (76,2) 2.4 (1,1) 4 x 2-1/2 (100 x 65) 4.50 x 2.87 (114,3 x 73,0) 3.00 (76,2) 2.7 (1,2)——3.00 (76,2) 2.7 (1,2) E to E E to E E to E FIGURE 550(1) CAST CONCENTRIC REDUCER FIGURE 350 FABRICATED CONCENTRIC REDUCER FIGURE 250 CAST CONCENTRIC REDUCER FIGURE 1 (1 OF 3) FIGURES 250, 350, AND 550 CONCENTRIC REDUCERS NOMINAL DIMENSIONS TFP1815 Page 3 of 26 1. Figure 550 is available for the America market only. Nominal Pipe Size Figure 250 Cast Figure 350 Fabricated Figure 550(1) Cast ANSI Inches (DN) O.D. Inches (mm) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) 4 x 76mm (100 x 65) 4.50 x 3.00 (114,3 x 76,1) 3.00 (76,2) 3.2 (1,5)——3.00 (76,2) 3.2 (1,5) 4 x 3 (100 x 80) 4.50 x 3.50 (114,3 x 88,9) 3.00 (76,2) 2.8 (1,3)——3.00 (76,2) 2.8 (1,3) 139mm x 3 (125 x 80) 5.50 x 3.50 (139,7 x 88,9) 3.50 (88,9) 4.2 (1,9)——3.50 (88,9) 4.2 (1,9) 139mm x 4 (125 x 100) 5.50 x 4.50 (139,7 x 114,3) 3.50 (88,9) 4.4 (2,0)——3.50 (88,9) 4.4 (2,0) 5 x 2 (125 x 50) 5.56 x 2.37 (141,3 x 60,3)——3.50 (88,9) 4.6 (2,1)—— 5 x 2-1/2 (125 x 65) 5.56 x 2.87 (141,3 x 73,0)——3.50 (88,9) 4.5 (2,0)—— 5 x 3 (125 x 80) 5.56 x 3.50 (141,3 x 88,9) 3.50 (88,9) 4.2 1,9)——3.50 (88,9) 4.2 1,9) 5 x 4 (125 x 100) 5.56 x 4.50 (141,3 x 114,3) 3.50 (88,9) 4.4 (2,0)——3.50 (88,9) 4.4 (2,0) 165mm x 3 (150 x 80) 6.50 x 3.50 (165,1 x 88,9) 4.00 (101,6) 5.5 (2,5)——4.00 (101,6) 5.5 (2,5) 165mm x 4 (150 x 100) 6.50 x 4.50 (165,1 x 114,3) 4.00 (101,6) 6.0. (2,7)——4.00 (101,6) 6.0. (2,7) 165mm x 139mm (150 x 125) 6.50 x 5.50 (165,1 x 139,7) 4.00 (101,6) 5.6 (2,5)——4.00 (101,6) 5.6 (2,5) 6 x 1 (150 x 25) 6.63 x 1.31 (168.3 x 33.7) 4.00 (101,6) 4.7 (2,1)——4.00 (101,6) 4.7 (2,1) 6 x 1-1/2 (150 x 40) 6.63 x 1.90 (168.3 x 48.3) 4.00 (101,6) 5.0 (2,3)——4.00 (101,6) 5.0 (2,3) 6 x 2 (150 x 50) 6.63 x 2.37 (168,3 x 60,3) 4.00 (101,6) 5.3 (2,4)——4.00 (101,6) 5.3 (2,4) 6 x 2-1/2 (150 x 65) 6.63 x 2.87 (168,3 x 73,0) 4.00 (101,6) 5.7 (2,6)——4.00 (101,6) 5.7 (2,6) 6 x 76mm (150 x 65) 6.63 x 3.00 (168,3 x 76,1) 4.00 (101,6) 6.1 (2,7)——4.00 (101,6) 6.1 (2,7) 6 x 3 (150 x 80) 6.63 x 3.50 (168,3 x 88,9) 4.00 (101,6) 5.8 (2,6)——4.00 (101,6) 5.8 (2,6) 6 x 108mm (150 x 100) 6.63 x 4.25 (168,3 x 108,0)——4.00 (101,6) 6.0 (2,7)—— 6 x 4 (150 x 100) 6.63 x 4.50 (168,3 x 114,3) 4.00 (101,6) 6.0 (2,7)——4.00 (101,6) 6.0 (2,7) 6 x 139mm (150 x 100) 6.63 x 5.50 (168,3 x 139,7) 4.00 (101,6) 6.3 (2,3)——4.00 (101,6) 6.3 (2,3) 6 x 5 (150 x 125) 6.63 x 5.56 (168,3 x 141,3) 4.00 (101,6) 6.2 (2,8)——4.00 (101,6) 6.2 (2,8) 216mm x 2-1/2 (200 x 65) 8.52 x 2.87 (216,3 x 73,0)——5.00 (127,0) 12.1 (5,5)—— 8 x 3 (200 x 80) 8.63 x 3.50 (219,1 x 88,9) 5.00 (127,0) 11.5 (5,2)——5.00 (127,0) 11.5 (5,2) 8 x 4 (200 x 100) 8.63 x 4.50 (219,1 x 114,3) 5.00 (127,0) 10.7 (4,9)——5.00 (127,0) 10.7 (4,9) E to E E to E E to E FIGURE 1 (2 OF 3) FIGURES 250, 350, AND 550 CONCENTRIC REDUCERS NOMINAL DIMENSIONS FIGURE 550 (1) CAST CONCENTRIC REDUCER FIGURE 350 FABRICATED CONCENTRIC REDUCER FIGURE 250 CAST CONCENTRIC REDUCER TFP1815 Page 4 of 26 1. Figure 550 is available for the America market only. Nominal Pipe Size Figure 250 Cast Figure 350 Fabricated Figure 550(1) Cast ANSI Inches (DN) O.D. Inches (mm) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) 8 x 139mm (200 x 125) 8.63 x 5.50 (219,1 x 139.7) 5.00 (127,0) 10.0 (4,5)——5.00 (127,0) 10.0 (4,5) 8 x 5 (200 x 125) 8.63 x 5.56 (219,1 x 141,3) 5.00 (127,0) 10.8 (4,9)——5.00 (127,0) 10.8 (4,9) 8 x 165mm (200 x 150) 8.63 x 6.50 (219,1 x 165.1) 5.00 (127,0) 11.0 (5,0)——5.00 (127,0) 11.0 (5,0) 8 x 6 (200 x 150) 8.63 x 6.63 (219,1 x 168,3) 5.00 (127,0) 11.3 (5,1)——5.00 (127,0) 11.3 (5,1) 10 x 4 (250 x 100) 10.75 x 4.50 (273,0 x 114,3)——6.00 (152,4) 20.5 (9,3)—— 10 x 5 (250 x 125) 10.75 x 5.56 (273,0 x 141,3)——6.00 (152,4) 20.1 (9,1)—— 10 x 165mm (250 x 150) 10.75 x 6.50 (273,0 x 165,1) 6.00 (152,4) 17.8 (8,0)——6.00 (152,4) 17.8 (8,0) 10 x 6 (250 x 150) 10.75 x 6.63 (273,0 x 168,3) 6.00 (152,4) 16.3 (7,4)——6.00 (152,4) 16.3 (7,4) 10 x 8 (250 x 200) 10.75 x 8.63 (273,0 x 219,1) 6.00 (152,4) 18.3 (8,3)——6.00 (152,4) 18.3 (8,3) 12 x 4 (300 x 100) 12.75 x 4.50 (323,9 x 114,3) 7.00 (177,8) 22.7 (10,3)——7.00 (177,8) 22.7 (10,3) 12 x 6 (300 x 150) 12.75 x 6.63 (323,9 x 168,3) 7.00 (177,8) 23.6 (10,7)——7.00 (177,8) 24.2 (11,0) 12 x 8 (300 x 200) 12.75 x 8.63 (323,9 x 219,1) 7.00 (177,8) 25.2 (11,4)——7.00 (177,8) 25.8 (11,7) 12 x 10 (300 x 250) 12.75 x 10.75 (323,9 x 273,0) 7.00 (177,8) 28.2 (12,8) 7.00 (177,8) 28.2 (12,8) 7.00 (177,8) 28.2 (12,8) E to E E to E E to E FIGURE 550 (1) CAST CONCENTRIC REDUCER FIGURE 350 FABRICATED CONCENTRIC REDUCER FIGURE 250 CAST CONCENTRIC REDUCER FIGURE 1 (3 OF 3) FIGURES 250, 350, AND 550 CONCENTRIC REDUCERS NOMINAL DIMENSIONS TFP1815 Page 5 of 26 Nominal Pipe Size Figure 501 Cast 45° Elbow Figure 510 Cast 90° Elbow ANSI Inches (DN) O.D. Inches (mm) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) 1 (25) 1.0 (33,7) 1.7 (43,2) 0.6 (0,3) 2.25 (57,2) 0.8 (0,4) 1-1/4 (32) 1.7 (42,4) 1.8 (44,5) 0.8 (0,4) 2.8 (69,9) 1.1 (0,5) 1-1/2 (40) 1.9 (48,3) 1.8 (44,5) 1.0 (0,5) 2.8 (69,9) 1.4 (0,6) 2 (50) 2.4 (60,3) 2.0 (50,8) 1.3 (0,6) 3.3 (82,6) 2.0 (0,9) 2-1/2 (65) 2.9 (73,0) 2.3 (57,2) 2.1 (1,0) 3.8 (95,3) 2.8 (1,3) 76,1mm (65) 3.0 (76,1) 2.3 (57,2) 2.2 (1,0) 3.8 (95,3) 3.0 (1,3) 3 (80) 3.5 (88,9) 2.5 (63,5) 3.4 (1,5) 4.3 (108,0) 4.1 (1,9) 4 (100) 4.5 (114,3) 3.0 (76,2) 5.5 (2,5) 5.0 (127,0) 7.0 (3,2) 139,1mm (125) 5.5 (139,7) 3.3 (82,6) 7.2 (3,3) 5.5 (139,7) 10.3 (4,7) 165,1mm (150) 6.5 (165,1) 3.5 (88,9) 9.2 (4,2) 6.5 (165,1) 13.9 (6,3) 6 (150) 6.6 (168,3) 3.5 (88,9) 11.2 (5,1) 6.5 (165,1) 15.2 (6,9) 8 (200) 8.6 (219,1) 4.5 (108,0) 20.6 (9,3) 7.8 (196,9) 29.6 (13,4) 10 (250) 10.750 (273,0) 4.75 (120,7) 30.1 (13,7) 9.00 (228,6) 52.0 (23,6) 12 (300) 12.750 (323,9) 5.25 (133,4) 48.0 (22,0) 10.00 (254,0) 66.4 (30,1) C to E C to E FIGURE 2 FIGURES 501 AND 510 ELBOWS NOMINAL DIMENSIONS FIGURE 501 CAST 45° ELBOW FIGURE 510 CAST 90° ELBOW TFP1815 Page 6 of 26 Nominal Pipe Size Figure 519 Cast Tee Figure 260(1) Cast End Cap ANSI Inches (DN) O.D. Inches (mm) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) 1 (25) 1.3 (33,4) 2.25 (57,2) 1.1 (0,5) 0.8 (21,1) 0.2 (0,1) 1-1/4 (32) 1.7 (42,4) 2.8 (69,9) 1.7 (0,8) 0.8 (21,1) 0.3 (0,1) 1-1/2 (40) 1.9 (48,3) 2.8 (69,9) 2.1 (1,00) 0.8 (21,1) 0.4 (0,2) 2 (50) 2.4 (60,3) 3.3 (82,6) 2.8 (1,3) 0.9 (23,4) 0.7 (0,3) 2-1/2 (65) 2.9 (73,0) 3.8 (95,3) 4.4 (2,0) 0.9 (23,4) 1.0 (0,5) 76,1mm (65) 3.0 (76,1) 3.8 (95,3) 4.5 (2,0) 0.9 (21,8) 1.3 (0,6) 3 (80) 3.5 (88,9) 4.3 (108,0) 6.5 (3,0) 0.9 (23,4) 1.4 (0,6) 4 (100) 4.5 (114,3) 5.0 (127,0) 9.5 (4,3) 1.0 (25,4) 2.6 (1,2) 139,1mm (125) 5.5 (139,7) 5.5 (139,7) 13.9 (6,3) 0.9 (23,4) 4.7 (2,1) 5 (125) 5.6 (141,3) 5.0 (127,0) 14.2 (6,4) 1.0 (25,4) 5.0 (2,3) 165,1mm (150) 6.5 (165,1) 6.5 (165,1) 19.7 (8,9) 0.9 (23,4) 6.4 (2,9) 6 (150) 6.6 (168,3) 6.5 (165,1) 22.4 (10,2) 1.0 (25,4) 6.2 (2,8) 8 (200) 8.6 (219,1) 7.8 (196,9) 39.8 (18,1) 1.1 (27,0) 7.1 (3,2) 10 (250) 10.8 (273,0) 9.00 (228,6) 64.2 (29,1) 1.0 (25,8) 24.5 (11,1) 12 (300) 12.8 (323,9) 10.00 (254,0) 110.0 (49,9) 1.0 (25,8) 31.0 (14,1) 1. Available with tapped plugs. Contact Tyco Fire Protection Products. C to E C to E E to E FIGURE 3 FIGURES 519 TEE AND FIGURE 260 END CAP NOMINAL DIMENSIONS FIGURE 519 CAST TEE FIGURE 260(1) CAST END CAP TFP1815 Page 7 of 26 Nominal Pipe Size Figure 510S 90° Elbow Figure 519S Tee ANSI Inches (DN) O.D. Inches (mm) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) 2 (50) 2.4 (60,3) 2.8 (69,9) 1.5 (0,7) 2.8 (69,9) 2.6 (1,2) 2-1/2 (65) 2.9 (73,0) 3.0 (76,2) 2.1 (1,0) 3.0 (76,2) 4.4 (2,0) 76,1mm (65) 3.0 (76,1) 3.0 (76,2) 2.3 (1,0) 3.0 (76,2) 3.1 (1,4) 3 (80) 3.5 (88,9) 3.4 (85,9) 3.0 (1,4) 3.8 (85,9) 6.5 (3,0) 4 (100) 4.5 (114,3) 4.0 (101,6) 5.0 (2,3) 4.0 (101,6) 10.7 (4,9) 139mm (125) 5.5 (139,7) 4.9 (124,0) 8.7 (3,9) 4.9 (124,0) 10.9 (5,0) 5 (125) 5.6 (141,3) 4.8 (123,0) 9.4 (4,3) 4.8 (123,0) 11.6 (5,3) 165,1mm (150) 6.5 (165,1) 5.5 (139,7) 11.4 (5,2) 5.5 (139,7) 14.8 (6,7) 6 (150) 6.6 (168,3) 5.5 (139,7) 12.1 (5,5) 5.5 (139,7) 15.0 (6,8) 8 (200) 8.6 (219,1) 6.9 (174,8) 22.2 (10,1) 6.9 (174,8) 39.8 (18,1) C to E C to E C to E FIGURE 4 FIGURES 510S ELBOW AND FIGURE 519S TEE NOMINAL DIMENSIONS FIGURE 510S 90° ELBOW SHORT PATTERN FIGURE 519S TEE SHORT PATTERN TFP1815 Page 8 of 26 Nominal Pipe Size Figure 510DE(1) 90° Drain Elbow ANSI Inches (DN) O.D. Inches (mm) Nominal C to E Inches (mm) Nominal A Inches (mm) Nominal B Inches (mm) Approx. Weight Lbs. (kg) 2 (50) 2.4 (60,3) 3.8 (95,3) 2.0 (50,8) 2.8 (69,9) 3.1 (1,4) 2-1/2 (65) 2.9 (73,0) 3.8 (95,3) 2.0 (50,8) 2.8 (69,9) 2.2 (1,0) 3 (80) 3.5 (88,9) 4.3 (108,0) 2.3 (59,4) 2.8 (69,9) 6.0 (2,7) 4 (100) 4.5 (114,3) 5.0 (127,0) 2.9 (72,4) 2.8 (69,9) 8.6 (3,9) 6 (150) 6.6 (168,3) 6.5 (165,1) 3.9 (99,6) 2.8 (69,9) 18.0 (8,2) 8 (200) 8.6 (219,1) 7.8 (196,9) 5.00 (125,7) 2.8 (69,9) 31.0 (14,1) 1. Figure 510DE not available for the EMEA market. Nominal Pipe Size Dimensions- Inches (mm)Approx. Weight Lbs. (kg) ANSI Inches (DN) Outlet NPT(1) A O.D. B Takeout CD 1-1/2 (40) 1/2 1.9 (48,3) 1.3 (31,8) 1.8 (44,5) 1.9 (48,0) 0.8 (0,4) 3/4 1.3 (31,8) 1.8 (44,5) 1.9 (48,0) 0.8 (0,4) 1 1.4 (34,8) 2.0 (50,8) 2.0 (51,3) 0.9 (0,4) 2 (50) 1/2 2.4 (60,3) 1.3 (31,8) 1.8 (44,5) 1.9 (48,0) 0.9 (0,4) 3/4 1.3 (31,8) 1.8 (44,5) 1.9 (48,0) 0.8 (0,4) 1 1.4 (34,8) 2.0 (50,8) 2.0 (51,3) 1.1 (0,5) 2-1/2 (65) 1/2 2.9 (73,0) 1.5 (37,3) 2.0 (50,0) 1.9 (48,0) 1.8 (0,8) 3/4 1.5 (37,3) 2.0 (50,0) 1.9 (48,0) 1.1 (0,5) 1 1.4 (34,8) 2.0 (50,8) 2.0 (51,3) 1.1 (0,5) 1. ISO threaded outlets are available upon request. 2. ADACAP not available for the EMEA market. 3. Rated pressure 300 psi (20,7 bar) C to E A B 1" NPT B D A CNPT FIGURE 5 FIGURE 510DE 90° DRAIN ELBOW NOMINAL DIMENSIONS FIGURE 6 ADACAP NOMINAL DIMENSIONS TFP1815 Page 9 of 26 Nominal Pipe Size Figure 320 Fabricated Thread Tee ANSI Inches (DN) O.D. Inches (mm) Nominal C to GE Inches (mm) Nominal C to TE Inches (mm) Approx. Weight Lbs. (kg) 1 (25) 1.31 (33,4) 2.25 (57,2) 2.25 (57,2) 1.3 (0,6) 1-1/4 (32) 1.66 (42,4) 2.75 (69,9) 2.75 (69,9) 1.5 (0,7) 1-1/2 (40) 1.90 (48,3) 2.75 (69,9) 2.75 (69,9) 1.9 (0,9) 2 (50) 2.37 (60,3) 3.25 (82,6) 4.25 (108,0) 3.2 (1,5) 2-1/2 (65) 2.87 (73,0) 3.75 (95,3) 3.75 (95,3) 4.0 (1,8) 76mm (65) 3.00 (76,1) 3.75 (95,3) 3.75 (95,3) 4.5 (2,0) 3 (80) 3.50 (88,9) 4.25 (108,0) 6.00 (152,4) 6.0 (2,7) 4 (100) 4.50 (114,3) 5.00 (127,0) 7.25 (184,2) 11.0 (5,0) 139mm (125) 5.50 (139,7) 5.50 (139,7) 5.50 (139,7) 21.0 (9,5) 5 (125) 5.56 (141,3) 5.50 (139,7) 5.50 (139,7) 23.0 (10,5) 165mm (150) 6.50 (165,1) 6.50 (165,1) 6.50 (165,1) 25 (11,3) 6 (150) 6.63 (168,3) 6.50 (165,1) 6.50 (165,1) 28.0 (12,7) 8 (200) 8.63 (219,1) 7.75 (196,9) 7.75 (196,9) 38.7 (17,6) 10 (250) 10.75 (273,0) 9.00 (228,6) 9.00 (228,6) 72.1 (32,8) 12 (300) 12.75 (323,9) 10.00 (254,0) 10.00 (254,0) 92.5 (42,0) 1. Figure 320 not available for the EMEA market. C to GE C to TE FIGURE 7 FIGURE 320 FABRICATED GROOVE X GROOVE X MALE THREAD TEES (SEGMENT WELDED) NOMINAL DIMENSIONS TFP1815 Page 10 of 26 Nominal Pipe Size Figure 221 Cast Reducing Tee Figure 321 Fabricated Reducing Tee ANSI Inches (DN) O.D. Inches (mm) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) 1-1/4 x 1-1/4 x 1 (32 x 32 x 25) 1.66 x 1.66 x 1.31 (42,4 x 42,4 x 33,4)——2.75 (69,9) 1.3 (0,6) 1-1/2 x 1-1/2 x 1 (40 x 40 x 25) 1.90 x 1.90 x 1.31 (48,3 x 48,3 x 33,4)——2.75 (69,9) 1.4 (0,6) 1-1/2 x 1-1/2 x 1-1/4 (40 x 40 x 32) 1.90 x 1.90 x 1.66 (48,3 x 48,3 x 42,4)——2.75 (69,9) 1.5 (0,7) 2 x 2 x 1 (50 x 50 x 25) 2.37 x 2.37 x 1.32 (60,3 x 60,3 x 33,4)——3.25 (82,6) 1.6 (0,7) 2 x 2 x 1-1/2 (50 x 50 x 40) 2.37 x 2.37 x 1.90 (60,3 x 60,3 x 48,3) 3.25 (82,6) 2.7 (1,2) 3.25 (82,6) 2.0 (0,9) 2-1/2 x 2-1/2 x 1 (65 x 65 x 25) 2.87 x 2.87 x 1.32 (73,0 x 73,0 x 33,4)——3.75 (95,3) 2.3 (1,1) 2-1/2 x 2-1/2 x 1-1/4 (65 x 65 x 32) 2.87 x 2.87 x 1.66 (73,0 x 73,0 x 42,4)——3.75 (95,3) 4.2 (1,9) 2-1/2 x 2-1/2 x 1-1/2 (65 x 65 x 40) 2.87 x 2.87 x 1.90 (73,0 x 73,0 x 48,3)——3.75 (95,3) 4.2 (1,9) 2-1/2 x 2-1/2 x 2 (65 x 65 x 50) 2.87 x 2.87 x 2.37 (73,0 x 73,0 x 60,3) 3.75 (95,3) 4.2 (1,9) 3.75 (95,3) 4.5 (2,0) 76mm x 76mm x 1 (65 x 65 x 25) 3.00 x 3.00 x 1.32 (76,1 x 76,1 x 33,4)——3.75 (95,3) 2.4 (1,1) 76mm x 76mm x 1-1/4 (65 x 65 x 32) 3.00 x 3.00 x 1.66 (76,1 x 76,1 x 42,4)——3.75 (95,3) 4.3 (2,0) 76mm x 76mm x 1-1/2 (65 x 65 x 40) 3.00 x 3.00 x 1.90 (76,1 x 76,1 x 48,3) 3.75 (95,3) 4.5 (2,0) 3.75 (95,3) 4.2 (1,9) 76mm x 76mm x 2 (65 x 65 x 50) 3.00 x 3.00 x 2.37 (76,1 x 76,1 x 60,3) 3.75 (95,3) 4.3 (2,0) 3.75 (95,3) 4.6 (2,1) 3 x 3 x 1 (80 x 80 x 25 3.50 x 3.50 x 1.32 (88,9 x 88,9 x 33,4) 4.25 (108,0) 5.6 (2,5) 4.25 (108,0) 6.0 (2,7) 3 x 3 x 1-1/4 (80 x 80 x 32) 3.50 x 3.50 x 1.66 (88,9 x 88,9 x 42,4)——4.25 (108,0) 6.1 (2,8) 3 x 3 x 1-1/2 (80 x 80 x 40) 3.50 x 3.50 x 1.90 (88,9 x 88,9 x 48,3) 4.25 (108,0) 5.9 (2,7) 4.25 (108,0) 6.2 (2,8) 3 x 3 x 2 (80 x 80 x 50) 3.50 x 3.50 x 2.37 (88,9 x 88,9 x 60,3) 4.25 (108,0) 6.0 (2,7) 4.25 (108,0) 6.4 (2,9) 3 x 3 x 2-1/2 (80 x 80 x 65) 3.50 x 3.50 x 2.87 (88,9 x 88,9 x 73,0) 4.25 (108,0) 6.2 (2,8) 4.25 (108,0) 6.5 (2,9) 3 x 3 x 76mm (80 x 80 x 65) 3.50 x 3.50 x 3.00 (88,9 x 88,9 x 76,1) 4.25 (108,0) 6.0 (2,7) 4.25 (108,0) 6.7 (3,0) 4 x 4 x 1 (100 x 100 x 25) 4.50 x 4.50 x 1.32 (114,3 x 114,3 x 33,4)——5.00 (127,0) 8.0 (3,7) 4 x 4 x 1-1/4 (100 x 100 x 32) 4.50 x 4.50 x 1.66 (114,3 x 114,3 x 42,4)——5.00 (127,0) 9.8 (4,4) 4 x 4 x 1-1/2 (100 x 100 x 40) 4.50 x 4.50 x 1.90 (114,3 x 114,3 x 48,3)——5.00 (127,0) 9.9 (4,5) 4 x 4 x 2 (100 x 100 x 50) 4.50 x 4.50 x 2.37 (114,3 x 114,3 x 60,3) 5.00 (127,0) 9.1 (4,1) 5.00 (127,0) 11.0 (5,0) 4 x 4 x 2-1/2 (100 x 100 x 65) 4.50 x 4.50 x 2.88 (114,3 x 114,3 x 73,0) 5.00 (127,0) 9.5 (4,3) 5.00 (127,0) 11.2 (5,1) 4 x 4 x 76mm (125 x 125 x 65) 4.50 x 4.50 x 3.00 (114,3 x 114,3 x 76,1) 5.00 (127,0) 9.5 (4,3) 5.00 (127,0 11.4 (5,2) C to E C to E C to E C to E FIGURE 8 (1 OF 3) FIGURES 221 AND 321 REDUCING TEES NOMINAL DIMENSIONS FIGURE 221 CAST TEE REDUCING GROOVED (SEGMENT WELDED) FIGURE 321 FABRICATED TEE REDUCING GROOVED (SEGMENT WELDED) TFP1815 Page 11 of 26 Nominal Pipe Size Figure 221 Cast Reducing Tee Figure 321 Fabricated Reducing Tee ANSI Inches (DN) O.D. Inches (mm) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) 4 x 4 x 3 (100 x 100 x 80) 4.50 x 4.50 x 3.50 (114,3 x 114,3 x 88,9) 5.00 (127,0) 9.7 (4,4) 5.00 (127,0 11.6 (5,3) 139,7mm x 139,7mm x 3 (125 x 125 x 80) 5.50 x 5.50 x 3.50 (139,7 x 139,7 x 88,9) 5.50 (139,7) 12.7 (5,8) 5.50 (139,7) 12.2 (5,5) 139,7mm x 139,7mm x 4 (125 x 125 x 100) 5.50 x 5.50 x 4.50 (139,7 x 139,7 x 114,3) 5.50 (139,7) 13.4 (6,1) 5.50 (139,7) 12.5 (5,7) 5 x 5 x 1 (125 x 125 x 25) 5.56 x 5.56 x 1.31 (141,3 x 141,3 x 33,4)——5.50 (139,7) 13.0 (5,9) 5 x 5 x 1-1/2 (125 x 125 x 40) 5.56 x 5.56 x 1.90 (141,3 x 141,3 x 48,3)——5.50 (139,7) 13.4 (6,1) 5 x 5 x 2 (125 x 125 x 50) 5.56 x 5.56 x 2.37 (141,3 x 141,3 x 60,3)——5.50 (139,7) 14.1 (6,4) 5 x 5 x 2-1/2 (125 x 125 x 65) 5.56 x 5.56 x 2.87 (141,3 x 141,3 x 73,0) 5.50 (139,7) 18.0 (8,2) 5.50 (139,7) 14.8 (6,7) 5 x 5 x 76mm (125 x 125 x 65) 5.56 x 5.56 x 3.00 (141,3 x 141,3 x 76,1)——5.50 (139,7) 15.3 (6,9) 5 x 5 x 3 (125 x 125 x 80) 5.56 x 5.56 x 3.50 (141,3 x 141,3 x 88,9) 5.50 (139,7) 14.0 (6,4) 5.50 (139,7) 16.0 (7,3) 5 x 5 x 4 (125 x 125 x 100) 5.56 x 5.56 x 4.50 (141,3 x 141,3 x 114,3) 5.50 (139,7) 13.9 (6,3) 5.50 (139,7) 16.4 (7,4) 165mm x 165mm x 3 (150 x 150 x 80) 6.50 x 6.50 x 3.50 (165,1 x 165,1 x 88,9) 6.50 (165,1) 18.0 8,2 6.50 (165,1) 22.0 (10,0) 165mm x 165mm x 4 (150 x 150 x 100) 6.50 x 6.50 x 4.50 (165,1 x 165,1 x 114,3) 6.50 (165,1) 19.5 8,9 6.50 (165,1) 22.6 (10,3) 165mm x 165mm x 5 (150 x 150 x 125) 6.50 x 6.50 x 5.50 (165,1 x 165,1 x 139,7)——6.50 (165,1) 23.2 (10,5) 165mm x 165mm x 139mm (150 x 150 x 125) 6.50 x 6.50 x 5.50 (165,1 x 165,1 x 141,3)——6.50 (165,1) 22.9 (10,4) 6 x 6 x 1 (150 x 150 x 25) 6.63 x 6.63 x 1.31 (168,3 x 168,3 x 33,4)——6.50 (165,1) 22.8 (10,3) 6 x 6 x 1-1/2 (150 x 150 x 40) 6.63 x 6.63 x 1.90 (168,3 x 168,3 x 48,3)——6.50 (165,1) 22.9 (10,4) 6 x 6 x 2 (150 x 150 x 50) 6.63 x 6.63 x 2.37 (168,3 x 168,3 x 60,3) 6.50 (165,1) 19.4 (8,8) 6.50 (165,1) 23.0 (10,4) 6 x 6 x 2-1/2 (150 x 150 x 65) 6.63 x 6.63 x 2.87 (168,3 x 168,3 x 73,0) 6.50 (165,1) 21.2 (9,8) 6.50 (165,1) 23.4 (10,6) 6 x 6 x 76mm (150 x 150 x 65) 6.63 x 6.63 x 3.00 (168,3 x 168,3 x 76,1) 6.50 (165,1) 21.2 9,8 6.50 (165,1) 23.5 (10,7) 6 x 6 x 3 (150 x 150 x 80) 6.63 x 6.63 x 3.50 (168,3 x 168,3 x 88,9) 6.50 (165,1) 21.0 (9,5) 6.50 (165,1) 23.7 (10,7) 6 x 6 x 4 (150 x 150 x 100) 6.63 x 6.63 x 4.50 (168,3 x 168,3 x 114,3) 6.50 (165,1) 21.8 (9,9) 6.50 (165,1) 23.9 (10,8) 6 x 6 x 139mm (150 x 150 x 125) 6.63 x 6.63 x 5.50 (168,3 x 168,3 x 139,7) 6.50 (165,1) 23.0 10,4 6.50 (165,1) 24.0 (10,9) 6 x 6 x 5 (150 x 150 x 125) 6.63 x 6.63 x 5.56 (168,3 x 168,3 x 141,3)——6.50 (165,1) 27.0 12,2 8 x 8 x 1-1/2 (200 x 200 x 40) 8.63 x 8.63 x 1.90 (219,1 x 219,1 x 48,3)——7.75 (196,9 36.0 (16,3) 8 x 8 x 2 (200 x 200 x 50) 8.63 x 8.63 x 2.375 (219,1 x 219,1 x 60,3)——7.75 (196,9) 36.2 (16,4) C to E C to E C to E C to E FIGURE 8 (2 OF 3) FIGURES 221 AND 321 REDUCING TEES NOMINAL DIMENSIONS FIGURE 221 CAST TEE REDUCING GROOVED (SEGMENT WELDED) FIGURE 321 FABRICATED TEE REDUCING GROOVED (SEGMENT WELDED) TFP1815 Page 12 of 26 Nominal Pipe Size Figure 221 Cast Reducing Tee Figure 321 Fabricated Reducing Tee ANSI Inches (DN) O.D. Inches (mm) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) 8 x 8 x 2-1/2 (200 x 200 x 65) 8.63 x 8.63 x 2.88 (219,1 x 219,1 x 73,0)——7.75 (196,9) 36.4 (16,5) 216mm x 216mm x 165mm (200 x 200 x 150) 8.52 x 8.52 x 6.50 (216,3 x 216,3 x 165,1)——7.75 (196,9) 37.9 (17,2) 8 x 8 x 76mm (200 x 200 x 65) 8.63 x 8.63 x 3.00 (216,1 x 219,1 x 76.1)——7.75 (196,9) 36.4 (16,5) 8 x 8 x 3 (200 x 200 x 80) 8.63 x 8.63 x 3.50 (219,1 x 219,1 x 88,9)——7.75 (196,9) 36.5 (16,6) 8 x 8 x 4 (200 x 200 x 100) 8.63 x 8.63 x 4.50 (219,1 x 219,1 x 114,1) 7.75 (196,9) 37.2 (16,9) 7.75 (196,9) 36.4 (16,5) 8 x 8 x 139mm (200 x 200 x 125) 8.63 x 8.63 x 5.56 (219,1 x 219,1 x 139,7) 7.75 (196,9) 37.7 (17,1) 7.75 (196,9) 36.7 (16,6) 8 x 8 x 5 (200 x 200 x 125) 8.63 x 8.63 x 5.50 (219,1 x 219,1 x 141,3)——7.75 (196,9) 36.8 (16,7) 8 x 8 x 165mm (200 x 200 x 150) 8.63 x 8.63 x 6.50 (219,1 x 219,1 x 165,1) 7.75 (196,9) 37.7 (17,1) 7.75 (196,9) 39.0 (17,7) 10 x 10 x 1-1/2 (250 x 250 x 40) 10.75 x 10.75 x 1.90 (273,0 x 273,0 x 48,3)——9.00 (228,6) 57.0 (25,8) 10 x 10 x 2 (250 x 250 x 50) 10.75 x 10.75 x 2.37 (273,0 x 273,0 x 60,3)——9.00 (228,6) 57.1 (25,9) 10 x 10 x 2-1/2 (250 x 250 x 65) 10.75 x 10.75 x 2.87 (273,0 x 273,0 x 73,0)——9.00 (228,6) 57.3 (26,0) 10 x 10 x 3 (250 x 250 x 80) 10.75 x 10.75 x 3.50 (273,0 x 273,0 x 88,9)——9.00 (228,6) 57.4 (26,0) 10 x 10 x 4 (250 x 250 x 100) 10.75 x 10.75 x 4.50 (273,0 x 273,0 x 114,3)——9.00 (228,6) 57.8 (26,2) 10 x 10 x 5 (250 x 250 x 125) 10.75 x 10.75 x 5.56 (273,0 x 273,0 x 141,3)——9.00 (228,6) 58.0 (26,3) 10 x 10 x 6 (250 x 250 x 150) 10.75 x 10.75 x 6.63 (273,0 x 273,0 x 168,3)——9.00 (228,6) 62.0 (28,1) 10 x 10 x 8 (250 x 250 x 200) 10.75 x 10.75 x 8.63 (273,0 x 273,0 x 219,1)——9.00 (228,6) 63.0 (28,6) 12 x 12 x 1 (300 x 300 x 25) 12.75 x 12.75 x 1.31 (323,9 x 323,9 x 33,4)——10.00 (254,0) 64.0 (29,0) 12 x 12 x 2 (300 x 300 x 50) 12.75 x 12.75 x 2.37 (323,9 x 323,9 x 60,3)——10.00 (254,0) 69.5 (31,5) 12 x 12 x 2-1/2 (300 x 300 x 65) 12.75 x 12.75 x 2.87 (323,9 x 323,9 x 73,0)——10.00 (254,0) 75.6 (34,3) 12 x 12 x 3 (300 x 300 x 80) 12.75 x 12.75 x 3.50 (323,9 x 323,9 x 88,9)——10.00 (254,0) 80.2 (36,4) 12 x 12 x 4 (300 x 300 x 100) 12.75 x 12.75 x 4.50 (323,9 x 323,9 x 114,3)——10.00 (254,0) 80.5 (36,5) 12 x 12 x 5 (300 x 300 x 125) 12.75 x 12.75 x 5.56 (323,9 x 323,9 x 141,3)——10.00 (254,0) 80.7 (36,6) 12 x 12 x 6 (300 x 300 x 150) 12.75 x 12.75 x 6.63 (323,9 x 323,9 x 168,3)——10.00 (254,0) 80.9 (36,7) 12 x 12 x 165mm (300 x 300 x 150) 12.75 x 12.75 x 6.50 (323,9 x 323,9 x 165,1)——10.00 (254,0) 79.9 (36,2) 12 x 12 x 8 (300 x 300 x 200) 12.75 x 12.75 x 8.63 (323,9 x 323,9 x 219,1)——10.00 (254,0) 76.3 (34,6) 12 x 12 x 10 (300 x 300 x 250) 12.75 x 12.75 x 10.75 (323,9 x 323,9 x 273,0)——10.00 (254,0) 77.6 (35,2) C to E C to E C to E C to E FIGURE 8 (3 OF 3) FIGURES 221 AND 321 REDUCING TEES NOMINAL DIMENSIONS FIGURE 221 CAST TEE REDUCING GROOVED (SEGMENT WELDED) FIGURE 321 FABRICATED TEE REDUCING GROOVED (SEGMENT WELDED) TFP1815 Page 13 of 26 Nominal Pipe Size Figure 327(1)Figure 341(1)Figure 342(1) ANSI Inches (DN) O.D. Inches (mm) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) Nominal E to E Inches (mm) Mating Flange Bolt Qty. Approx. Weight Lbs. (kg) Nominal E to E Inches (mm) Mating Flange Bolt Qty. Approx. Weight Lbs. (kg) 1 (25) 1.31 (33,4) 2.25 (57,2) 2.2 (1,0) 3.00 (76,2)4 2.3 (1,0) 3.00 (76,2)4 4.0 (1,8) 1-1/4 (32) 1.66 (42,4) 2.75 (69,9) 2.2 (1,0) 4.00 (101,6)4 2.8 (1,3) 4.00 (101,6)4 4.6 (2,1) 1-1/2 (40) 1.90 (48,3) 2.75 (69,9) 2.5 (1,1) 4.00 (101,6)4 3.2 (1,5) 4.00 (101,6)4 7.1 (3,2) 2 (50) 2.37 (60,3) 3.25 (82,6) 3.7 (1,7) 4.00 (101,6)4 5.2 (2,4) 4.00 (101,6)8 8.2 (3,7) 2-1/2 (65) 2.87 (73,0) 3.75 (95,3) 5.8 (2,6) 4.00 (101,6)4 8.0 (3,6) 4.00 (101,6)8 11.9 (5,4) 76mm (65) 3.00 (76,1) 3.75 (95,3) 6.0 (2,7) 4.00 (101,6)4 8.8 (4,0) 4.00 (101,6)8 12.5 (5,7) 3 (80) 3.50 (88,9) 4.25 (108,0) 8.6 (3,9) 4.00 (101,6)4 10.2 (4,6) 4.00 (101,6)8 15.5 (7,0) 4 (100) 4.50 (114,3) 5.00 (127,0) 20.7 (9,4) 6.00 (152,4)8 17.2 (7,8) 6.00 (152,4)8 28.0 (12,7) 139mm (125) 5.50 (139,7) 5.50 (139,7) 18.3 (8,3) 6.00 (152,4)8 18.5 (8,4) 6.00 (152,4)8 32.5 (14,7) 5 (125) 5.56 (141,3) 5.50 (139,7) 18.5 (8,4) 6.00 (152,4)8 21.4 (9,7) 6.00 (152,4)8 37.0 (16,8) 165mm (150) 6.50 (165,1) 6.50 (165,1) 26.2 (11,9) 6.00 (152,4)8 22.0 (10,0) 6.00 (152,4)12 42.5 (19,3) 6 (150) 6.63 (168,3) 6.50 (165,1) 27.3 (12,4) 6.00 (152,4)8 26.0 (11,8) 6.00 (152,4)12 48.0 (21,8) 216mm (200) 8.52 (216,3) 7.75 (196,9) 44.0 (20,0) 6.00 (152,4)8 34.5 (15,6) 6.00 (152,4)12 72.5 (32,9) 8 (200) 8.63 (219,1) 7.75 (196,9) 48.0 (21,7) 6.00 (152,4)8 38.4 (17,4) 6.00 (152,4)12 79.0 (35,8) 10 (250) 10.75 (273,0) 9.00 (228,6) 75.0 (34,0) 8.00 (203,2)12 65.0 (29,5) 8.00 (203,2)16 122.0 (55,3) 12 (300) 12.75 (323,9) 10.00 (254,0) 95.8 (43,4) 8.00 (203,2)12 91.0 (41,3) 8.00 (203,2)16 183.0 (83,0) 1. Figure 327, Figure 341, and Figure 342 are not available for the EMEA market. C to E C to E E to E FIGURE 9 FIGURE 327 CROSS AND FIGURE 341 AND FIGURE 342 FLANGE ADAPTERS NOMINAL DIMENSIONS FIGURE 341(1) FABRICATED FLANGE ADAPTER ANSI CLASS 150 LBS. GROOVED FIGURE 342(1) FABRICATED FLANGE ADAPTER ANSI CLASS 300 LBS. GROOVED FIGURE 327(1) FABRICATED CROSS GROOVED (SEGMENT WELDED) TFP1815 Page 14 of 26 1. Figure 323 not available for the EMEA market. Nominal Pipe Size Nominal C to E Inches (mm) Approx. Weight Lbs. (kg)ANSI Inches (DN) O.D. Inches (mm) 2 x 2 x 3/4 (50 x 50 x 20) 2.37 x 2.37 x 1.05 (60,3 x 60,3 x 26,7) 3.25 (82,6) 2.0 (0,9) 2 x 2 x 1 (50 x 50 x 25) 2.37 x 2.37 x 1.31 (60,3 x 60,3 x 33,4) 3.25 (82,6) 2.2 (1,0) 2 x 2 x 1-1/4 (50 x 50 x 32) 2.37 x 2.37 x 1.66 (60,3 x 60,3 x 42,4) 3.25 (82,6) 2.3 (1,0) 2 x 2 x 1-1/2 (50 x 50 x 40) 2.37 x 2.37 x 1.90 (60,3 x 60,3 x 48,3) 3.25 (82,6) 1.4 (1,1) 2-1/2 x 2-1/2 x 1 (65 x 65 x 25) 2.875 x 2.875 x 1.315 (73,0 x 73,0 x 33,4) 3.75 (95,3) 3.6 (1,6) 2-1/2 x 2-1/2 x 1-1/4 (65 x 65 x 32) 2.875 x 2.875 x 1.660 (73,0 x 73,0 x 42,4) 3.75 (95,3) 3.8 (1,7) 2-1/2 x 2-1/2 x 1-1/2 (65 x 65 x 40) 2.875 x 2.875 x 1.900 (73,0 x 73,0 x 48,3) 3.75 (95,3) 4.0 (1,8) 2-1/2 x 2-1/2 x 2 (65 x 65 x 50) 2.875 x 2.875 x 2.375 (73,0 x 73,0 x 60,3) 3.75 (95,3) 4.2 (1,9) 76mm x 76mm x 1 (65 x 65 x 25) 3.00 x 3.00 x 1.31 (76,1 x 76,1 x 33,4) 3.75 (95,3) 3.8 (1,7) 76mm x 76mm x 1-1/4 (65 x 65 x 32) 3.00 x 3.00 x 1.66 (76,1 x 76,1 x 42,4) 3.75 (95,3) 4.0 (1,8) 76mm x 76mm x 1-1/2 (65 x 65 x 40) 3.00 x 3.00 x 1.90 (76,1 x 76,1 x 48,3) 3.75 (95,3) 4.2 (1,9) 3 x 3 x 3/4 (80 x 80 x 20) 3.50 x 3.50 x 1.05 (88,9 x 88,9 x 26,7) 4.25 (108,0) 5.2 (2,4) 3 x 3 x 1 (80 x 80 x 25) 3.50 x 3.50 x 1.31 (88,9 x 88,9 x 33,4) 4.25 (108,0) 5.7 (2,6) 3 x 3 x 1-1/2 (80 x 80 x 40) 3.50 x 3.50 x 1.90 (88,9 x 88,9 x 48,3) 4.25 (108,0) 5.8 (2,6) 3 x 3 x 2 (80 x 80 x 50) 3.50 x 3.50 x 2.37 (88,9 x 88,9 x 60,3) 4.25 (108,0) 5.9 (2,7) 3 x 3 x 2-1/2 (80 x 80 x 65) 3.50 x 3.50 x 2.87 (88,9 x 88,9 x 73,0) 4.25 (108,0) 6.3 (2,9) 3 x 3 x 76mm (80 x 80 x 65) 3.50 x 3.50 x 3.00 (88,9 x 88,9 x 76,1) 4.25 (108,0) 6.5 (2,9) 4 x 4 x 3/4 (100 x 100 x 20) 4.50 x 4.50 x 1.05 (114,3 x 114,3 x 26,7) 3.75 (95,3) 6.4 (2,9) 4 x 4 x 1 (100 x 100 x 25) 4.50 x 4.50 x 1.31 (114,3 x 114,3 x 33,4) 5.00 (127,0) 6.9 (3,1) 4 x 4 x 1-1/4 (100 x 100 x 32) 4.50 x 4.50 x 1.66 (114,3 x 114,3 x 42,4) 5.00 (127,0) 7.6 (3,4) 4 x 4 x 1-1/2 (100 x 100 x 40) 4.50 x 4.50 x 1.90 (114,3 x 114,3 x 48,3) 5.00 (127,0) 8.3 (3,8) 4 x 4 x 2 (100 x 100 x 50) 4.50 x 4.50 x 2.37 (114,3 x 114,3 x 60,3) 5.00 (127,0) 9.6 (4,4) 4 x 4 x 2-1/2 (100 x 100 x 65) 4.500 x 4.500 x 2.875 (114,3 x 114,3 x 73,0) 5.00 (127,0) 10.0 (4,5) 4 x 4 x 76mm (100 x 100 x 65) 4.500 x 4.500 x 3.00 (114,3 x 114,3 x 76,1) 5.00 (127,0) 10.5 (4,8) C to E C to E FIGURE 10 (1 OF 3) FIGURE 323 FABRICATED GROOVE X GROOVE X MALE THREAD REDUCING TEES (SEGMENT WELDED) NOMINAL DIMENSIONS TFP1815 Page 15 of 26 1. Figure 323 not available for the EMEA market. Nominal Pipe Size Nominal C to E Inches (mm) Approx. Weight Lbs. (kg)ANSI Inches (DN) O.D. Inches (mm) 4 x 4 x 3 (100 x 100 x 80) 4.50 x 4.50 x 3.50 (114,3 x 114,3 x 88,9) 5.00 (127,0) 10.3 (4,7) 5 x 5 x 2 (125 x 125 x 50) 5.56 x 5.56 x 2.37 (141,3 x 141,3 x 60,3) 5.50 (139,7) 14.0 (6,4) 5 x 5 x 2-1/2 (125 x 125 x 65) 5.56 x 5.56 x 2.87 (141,3 x 141,3 x 73,0) 5.50 (139,7) 14.3 (6,5) 5 x 5 x 76mm (125 x 125 x 65) 5.56 x 5.56 x 3.00 (141,3 x 141,3 x 76,1) 5.50 (139,7) 14.5 (6,6) 5 x 5 x 3 (125 x 125 x 80) 5.56 x 5.56 x 3.50 (141,3 x 141,3 x 88,9) 5.50 (139,7) 14.6 (6,6) 5 x 5 x 4 (125 x 125 x 100) 5.56 x 5.56 x 4.50 (141,3 x 141,3 x 114,3) 5.50 (139,7) 15.1 (6,8) 165mm x 165mm x 2 (150 x 150 x 50) 6.50 x 6.50 x 2.37 (165,1 x 165,1 x 60,3) 6.50 (165,1) 9.5 (4,3) 165mm x 165mm x 2-1/2 (150 x 150 x 65) 6.50 x 6.50 x 2.875 (165,1 x 165,1 x 73,0) 6.50 (165,1) 9.7 (4,4) 165mm x 165mm x 76mm (150 x 150 x 65) 6.50 x 6.50 x 3.00 (165,1 x 165,1 x 76,1) 6.50 (165,1) 9.7 (4,4) 165mm x 165mm x 3 (150 x 150 x 80) 6.50 x 6.50 x 3.50 (165,1 x 165,1 x 88,9) 6.50 (165,1) 9.8 (4,4) 165mm x 165mm x 4 (150 x 150 x 100) 6.50 x 6.50 x 4.50 (165,1 x 165,1 x 114,3) 6.50 (165,1) 10.0 (4,5) 165mm x 165mm x 5 (150 x 150 x 125) 6.50 x 6.50 x 5.563 (165,1 x 165,1 x 141,3) 6.50 (165,1) 10.2 (4,6) 6 x 6 x 1-1/2 (150 x 150 x 40) 6.625 x 6.625 x 1.90 (168,3 x 168,3 x 48,3) 6.50 (165,1) 19.0 (8,6) 6 x 6 x 2 (150 x 150 x 50) 6.625 x 6.625 x 2.375 (168,3 x 168,3 x 60,3) 6.50 (165,1) 21.3 (9,7) 6 x 6 x 2-1/2 (150 x 150 x 65) 6.625 x 6.625 x 2.875 (168,3 x 168,3 x 73,0) 6.50 (165,1) 21.7 (9,8) 6 x 6 x 76mm (150 x 150 x 65) 6.625 x 6.625 x 3.00 (168,3 x 168,3 x 76,1) 6.50 (165,1) 14.5 (6,6) 6 x 6 x 3 (150 x 150 x 80) 6.625 x 6.625 x 3.500 (168,3 x 168,3 x 88,9) 6.50 (165,1) 22.0 (10,0) 6 x 6 x 4 (150 x 150 x 100) 6.625 x 6.625 x 4.500 (168,3 x 168,3 x 114,3) 6.50 (165,1) 22.5 (10.2) 6 x 6 x 5 (150 x 150 x 125) 6.625 x 6.625 x 5.563 (168,3 x 168,3 x 141,3) 6.50 (165,1) 23.1 10,5 8 x 8 x 2 (200 x 200 x 50) 8.63 x 8.63 x 2.37 (219,1 x 219,1 x 60,3) 7.75 (196,9) 32.7 (14,8) 8 x 8 x 3 (200 x 200 x 80) 8.63 x 8.63 x 3.50 (219,1 x 219,1 x 88,9) 7.75 (196,9) 33.5 (15,2) 8 x 8 x 4 (200 x 200 x 100) 8.63 x 8.63 x 4.50 (219,1 x 219,1 x 114,1) 7.75 (196,9) 34.5 (15,6) 8 x 8 x 5 (200 x 200 x 125) 8.63 x 8.63 x 5.56 (219,1 x 219,1 x 141,3) 7.75 (196,9) 34.7 (15,7) 8 x 8 x 165mm (200 x 200 x 150) 8.63 x 8.63 x 6.50 (219,1 x 219,1 x 165,1) 7.75 (196,9) 35.0 (15,9) C to E C to E FIGURE 10 (2 OF 3) FIGURE 323 FABRICATED GROOVE X GROOVE X MALE THREAD REDUCING TEES (SEGMENT WELDED) NOMINAL DIMENSIONS TFP1815 Page 16 of 26 1. Figure 323 not available for the EMEA market. Nominal Pipe Size Nominal C to E Inches (mm) Approx. Weight Lbs. (kg)ANSI Inches (DN) O.D. Inches (mm) 8 x 8 x 6 (200 x 200 x 150) 8.63 x 8.63 x 6.63 (219,1 x 219,1 x 168,3) 7.75 (196,9) 35.6 (16,1) 10 x 10 x 2 (250 x 250 x 50) 10.75 x 10.75 x 2.37 (273,0 x 273,0 x 60,3) 9.00 (228,6) 52.2 (23,7) 10 x 10 x 3 (250 x 250 x 80) 10.75 x 10.75 x 3.50 (273,0 x 273,0 x 88,9) 9.00 (228,6) 53.0 (24,0) 10 x 10 x 4 (250 x 250 x 100) 10.75 x 10.75 x 4.50 (273,0 x 273,0 x 114,3) 9.00 (228,6) 53.6 (24,3) 10 x 10 x 5 (250 x 250 x 125) 10.75 x 10.75 x 5.56 (273,0 x 273,0 x 141,3) 9.00 (228,6) 54.2 (24,6) 10 x 10 x 165mm (250 x 250 x 150) 10.75 x 10.75 x 6.50 (273,0 x 273,0 x 165,1) 9.00 (228,6) 55.5 (25,2) 10 x 10 x 6 (250 x 250 x 150) 10.75 x 10.75 x 6.63 (273,0 x 273,0 x 168,3) 9.00 (228,6) 54.9 (24,9) 10 x 10 x 8 (250 x 250 x 200) 10.75 x 10.75 x 8.63 (273,0 x 273,0 x 219,1) 9.00 (228,6) 55.3 (25,1) 12 x 12 x 3 (300 x 300 x 80) 12.75 x 12.75 x 3.50 (323,9 x 323,9 x 88,9) 10.00 (254,0) 74.6 (33,8) 12 x 12 x 4 (300 x 300 x 100) 12.75 x 12.75 x 4.50 (323,9 x 323,9 x 141,3) 10.00 (254,0) 75.1 (34,1) 12 x 12 x 5 (300 x 300 x 125) 12.75 x 12.75 x 5.563 (323,9 x 323,9 x 114,3) 10.00 (254,0) 75.6 (34,3) 12 x 12 x 165mm (300 x 300 x 150) 12.75 x 12.75 x 6.50 (323,9 x 323,9 x 165,1) 10.00 (254,0) 76.2 (34,6) 12 x 12 x 6 (300 x 300 x 150) 12.75 x 12.75 x 6.625 (323,9 x 323,9 x 168,3) 10.00 (254,0) 76.2 (34,6) 12 x 12 x 8 (300 x 300 x 200) 12.750 x 12.750 x 8.625 (323,9 x 323,9 x 219,1) 10.00 (254,0) 76.3 (34,6) 12 x 12 x 10 (300 x 300 x 250) 12.750 x 12.750 x 10.750 (323,9 x 323,9 x 273,0) 10.00 (254,0) 77.6 (35,2) C to E C to E FIGURE 10 (3 OF 3) FIGURE 323 FABRICATED GROOVE X GROOVE X MALE THREAD REDUCING TEES (SEGMENT WELDED) NOMINAL DIMENSIONS TFP1815 Page 17 of 26 1. Figure 372 not available for the EMEA market. Nominal Pipe Size E to E Inches (mm) Approx. Weight Lbs. (kg)ANSI Inches (DN) Pipe O.D. Inches (mm) 1-1/2 x 1 (40 x 25) 1.90 x 1.31 (48,3 x 33,7) 2.50 (63,5) 0.6 (0,3) 2 x 3/4 (50 x 20) 2.37 x 1.05 (60,3 x 26,7) 2.50 (63,5) 1.0 (0,5) 2 x 1 (50 x 25) 2.37 x 1.31 (60,3 x 33,4) 2.50 (63,5) 0.8 (0,4) 2 x 1-1/4 (50 x 32) 2.37 x 1.66 (60,3 x 42,4) 2.50 (63,5) 0.8 (0,4) 2 x 1-1/2 (50 x 40) 2.37 x 1.90 (60,3 x 48,3) 2.50 (63,5) 0.8 (0,4) 2-1/2 x 1 (65 x 25) 2.87 x 1.31 (73,0 x 33,4) 2.50 (63,5) 0.9 (0,4) 2-1/2 x 1-1/4 (65 x 32) 2.87 x 1.66 (73,0 x 42,4) 2.50 (63,5) 1.0 (0,5) 2-1/2 x 1-1/2 (65 x 40) 2.87 x 1.90 (73,0 x 48,3) 2.50 (63,5) 1.3 (0,6) 2-1/2 x 2 (65 x 50) 2.87 x 2.37 (73,0 x 60,3) 2.50 (63,5) 1.2 (0,5) 76mm x 1-1/4 (65 x 32) 3.00 x 1.66 (76,1 x 42,4) 2.50 (63,5) 1.0 (0,5) 76mm x 1-1/2 (65 x 40) 3.00 x 1.90 (76,1 x 48,3) 2.50 (63,5) 1.1 (0,5) 76mm x 2 (65 x 50) 3.00 x 2.37 (76,1 x 60,3) 2.50 (63,5) 1.2 (0,5) 3 x 3/4 (80 x 20) 3.50 x 1.05 (88,9 x 26,7) 2.50 (63,5) 1.1 (0,5) 3 x 1 (80 x 25) 3.50 x 1.31 (88,9 x 33,4) 2.50 (63,5) 1.3 (0,6) 3 x 1-1/4 (80 x 32) 3.50 x 1.66 (88,9 x 42,4) 2.5 (63,5) 1.3 (0,6) 3 x 1-1/2 (80 x 40) 3.50 x 1.90 (88,9 x 48,3) 2.50 (63.5) 1.3 (0,6) 3 x 2 (80 x 50) 3.50 x 2.37 (88,9 x 60,3) 2.50 (63.5) 1.3 (0,6) 3 x 2-1/2 (80 x 65) 3.50 x 2.87 (88,9 x 73,0) 2.50 (63.5) 1.5 (0,7) 3 x 76mm (80 x 65) 3.50 x 3.00 (88,9 x 76,1) 2.50 (63.5) 1.5 (0,7) 4 x 1 (100 x 25) 4.50 x 1.31 (114,3 x 33,4) 3.00 (76,2) 1.8 (0,8) 4 x 1-1/4 (100 x 32) 4.50 x 1.66 (114,3 x 42,4) 3.00 (76,2) 2.0 (0,9) 4 x 1-1/2 (100 x 40) 4.50 x 1.90 (114,3 x 48,3) 3.00 (76,2) 2.3 (1,0) 4 x 2 (100 x 50) 4.50 x 2.37 (114,3 x 60,3) 3.00 (76,2) 2.3 (1,0) 4 x 2-1/2 (100 x 65) 4.50 x 2.87 (114,3 x 73,0) 3.00 (76,2) 2.3 (1,0) E to E FIGURE 11 (1 OF 2) FIGURE 372 FABRICATED CONCENTRIC REDUCER GROOVE X MALE THREAD (MPT) NOMINAL DIMENSIONS TFP1815 Page 18 of 26 1. Figure 372 not available for the EMEA market. Nominal Pipe Size E to E Inches (mm) Approx. Weight Lbs. (kg)ANSI Inches (DN) Pipe O.D. Inches (mm) 4 x 3 (100 x 80) 4.50 x 3.50 (114,3 x 88,9) 3.00 (76,2) 2.6 (1,2) 5 x 4 (125 x 100) 5.56 x 4.50 (141,3 x 114,3) 3.50 (88,9) 4.5 (2,0) 165mm x 1 (150 x 25) 6.50 x 1.31 (165,1 x 33,4) 4.00 (101,6) 1.2 (0,5) 165mm x 2 (150 x 50) 6.50 x 2.37 (165,1 x 60,3) 4.00 (101,6) 5.5 (2,5) 165mm x 76mm (150 x 65) 6.50 x 3.00 (165,1 x 76,1) 4.00 (101,6) 5.7 (2,6) 165mm x 3 (150 x 50) 6.50 x 3.50 (165,1 x 88,9) 4.00 (101,6) 5.8 (2,6) 165mm x 4 (150 x 50) 6.50 x 4.50 (165,1 x 114,3) 4.00 (101,6) 5.8 (2,6) 165mm x 5 (150 x 50) 6.50 x 5.563 (165,1 x 141,3) 4.00 (101,6) 5.8 (2,6) 6 x 1 (150 x 25) 6.63 x 1.31 (168,3 x 33,4) 4.00 (101,6) 5.2 (2,4) 6 x 2 (150 x 50) 6.63 x 2.37 (168,3 x 60,3) 4.00 (101,6) 5.4 (2,4) 6 x 2-1/2 (150 x 65) 6.63 x 2.87 (168,3 x 73,0) 4.00 (101,6) 5.6 (2,5) 6 x 76mm (150 x 65) 6.63 x 3.00 (168,3 x 76,1) 4.00 (101,6) 5.8 (2,6) 6 x 3 (150 x 80) 6.63 x 3.50 (168,3 x 88,9) 4.00 (101,6) 6.0 (2,7) 6 x 4 (150 x 100) 6.63 x 4.50 (168,3 x 114,3) 4.00 (101,6) 6.2 (2,8) 6 x 5 (150 x 125) 6.63 x 5.56 (168,3 x 141,3) 4.00 (101,6) 6.7 (3,0) E to E FIGURE 11 (2 OF 2) FIGURE 372 FABRICATED CONCENTRIC REDUCER GROOVE X MALE THREAD (MPT) NOMINAL DIMENSIONS TFP1815 Page 19 of 26 Nominal Pipe Size Figures 211, 311, & 511 Figures 212, 312, & 512 ANSI Inches (DN) O.D. Inches (mm) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) Nominal C to E Inches (mm) Approx. Weight Lbs. (kg) 1-1/4 (32) 1.660 (42,4) 1.38 (35,1) 0.4 (0,2) 1.75 (44,5) 0.4 (0,2) 1-1/2 (40) 1.900 (48,3) 1.38 (35,1) 0.5 (0,2) 1.75 (44,5) 0.5 (0,2) 2 (50) 2.375 (60,3) 1.38 (35,1) 0.6 (0,3) 1.88 (47,8) 0.6 (0,3) 2-1/2 (65) 2.875 (73,0) 1.50 (38,1) 1.1 (0,5) 2.00 (50,8) 0.7 (0.3) 76,1mm (65) 3.000 (76,1) 1.50 (38,1) 1.1 (0,5) 2.00 (50,8) 1.2 (0,5) 3 (80) 3.500 (88,9) 1.50 (38,1) 1.2 (0,5) 2.25 (57,2) 1.4 (0,6) 4 (100) 4.500 (114,3) 1.75 (44,5) 2.2 (1,0) 2.63 (66,8) 2.4 (1,1) 139,7mm (125) 5.500 (139,7) 2.00 (50,8) 2.3 (1,0) 2.88 (73,2) 2.5 (1,1) 5 (125) 5.563 (141,3) 2.00 (50,8) 3.3 (1,5) 2.88 (73,2) 4.1 (1,9) 165,1mm (150) 6.500 (165,1) 2.00 (50.8) 3.5 (1,6) 3.13 (79,5) 4.3 (2,0) 6 (150) 6.625 (168,3) 2.00 (50.8) 4.6 (2,1) 3.13 (79,5) 5.6 (2,5) 8 (200) 8.625 (219,1) 2.00 (50,8) 8.7 (3,9) 3.88 (98,6) 11.1 (5,0) 10 (250) 10.750 (273,0) 2.13 (54,1) 9.1 (4,1) 4.38 (111,3) 14.0 (6,4) 12 (300) 12.750 (323,9) 2.25 (57,2) 16.7 (7,6) 4.88 (124,0) 22.0 (10,0) C to E C to E FIGURE 12 FIGURES 211, 311, AND 511 FABRICATED ELBOWS AND FIGURES 212, 312, AND 512 FABRICATED ELBOWS NOMINAL DIMENSIONS FIGURES 212, 312, & 512 FABRICATED 22½° ELBOW (SEGMENT WELDED) FIGURES 211, 311, & 511 FABRICATED 11¼° ELBOW (SEGMENT WELDED) TFP1815 Page 20 of 26 Nominal Pipe Size Figures 391, 392 & 393(1) ANSI Inches (DN) O.D. Inches (mm) Nominal E to E Inches (mm) Approx. Weight Lbs. (kg) 1-1/4 (32) 1.660 (42,4) 4.00 (101,6) 0.8 (0,4) 1-1/2 (40) 1.900 (48,3) 4.00 (101,6) 0.9 (0,4) 2 (50) 2.375 (60,3) 4.00 (101,6) 1.2 (0,5) 2-1/2 (65) 2.875 (73,0) 4.00 (101,6) 1.9 (0,9) 76,1mm (65) 3.000 (76,1) 4.00 (101,6) 1.9 (0,9) 3 (80) 3.500 (88,9) 4.00 (101,6) 2.5 (1,1) 4 (100) 4.500 (114,3) 6.00 (154,4) 5.5 (2,5) 139,7mm (125) 5.500 (139,7) 6.00 (154,4) 5.6 (2,5) 5 (125) 5.563 (141,3) 6.00 (154,4) 7.4 (3,4) 165,1mm (150) 6.500 (165,1) 6.00 (154,4) 7.6 (3,4) 6 (150) 6.625 (168,3) 6.00 (154,4) 9.5 (4,3) 8 (200) 8.625 (219,1) 6.00 (154,4) 14.2 (6,4) 10 (250) 10.750 (273,0) 8.00 (203,2) 27.0 (12,2) 12 (300) 12.750 (323,9) 8.00 (203,2) 33.0 (15,0) 1. Figure 391, Figure 392, and Figure 393 are not available for the EMEA market. E to E E to E E to E FIGURE 391(1) FABRICATED ADAPTER NIPPLE GROOVE X MALE THREAD (MA) FIGURE 392(1) FABRICATED ADAPTER NIPPLE GROOVE X GROOVE FIGURE 393(1) FABRICATED ADAPTER NIPPLE GROOVE X PLAIN FIGURE 13 FIGURES 391, 392, AND 393 FABRICATED ADAPTER NIPPLES NOMINAL DIMENSIONS TFP1815 Page 21 of 26 FIGURE 15 FIGURE 328 FABRICATED STANDPIPE TEE NOMINAL DIMENSIONS ANSI Inches (DN) O.D. Inches (mm) Nominal C to GE Inches (mm) Nominal C to TE Inches (mm) Approx. Weight Lbs. (kg) 4 x 4 x 2-1/2 (100 X 100 X 65) 5.563 x 5.563 x 8.625 (141,3 x 141,3 x 219,1) 13.313 (388,14) 9.313 (236,55) 8.7 (3,9) 6 x 6 x 2-1/2 (150 X 50 X 65) 6.625 x 6.625 x 8.625 (168,3 x 168,3 x 219,1) 13.313 (388,14) 8-3/4 (222,25) 13.7 (6,2) 1. Figure 328 not available for the EMEA and APAC market. ANSI Inches (DN) O.D. Inches (mm) Nominal C to GE Inches (mm) Nominal C to TE Inches (mm) Approx. Weight Lbs. (kg 5 x 5 x 8 (125 X 125 X 200) 5.563 x 5.563 x 8.625 (141,3 x 141,3 x 219,1) 13.313 (388,14) 9.313 (236,55) 27.8 (12,6) 6 x 6 x 8 (150 X 150 X 200) 6.625 x 6.625 x 8.625 (168,3 x 168,3 x 219,1) 13.313 (388,14) 8-3/4 (222,25) 36.7 (16,4) 1. Figure 507/50L not available for the EMEA market. C to GE C to TE C to TE C to GE FIGURE 14 FIGURE 507/50L FABRICATED BULLHEAD TEE NOMINAL DIMENSIONS TFP1815 Page 22 of 26 Friction Resistance Nominal Pipe Size Elbows 90° Feet (m) Elbows 45° Feet (m) Tee(1) Branch Feet (m) Tee Run Feet (m)ANSI Inches (DN) O.D. Inches (mm) 1 (25) 1.31 (33,4) 1.3 (0,4) 0.8 (0.3) 3.7 (1,1) 1.3 (0.6) 1-1/4 (32) 1.7 (42,4) 1.9 (0,6) 1.0 (0,3) 4.8 (1,5) 1.9 (0,6) 1-1/2 (40) 1.9 (48,3) 2.3 (0,7) 1.2 (0,4) 5.8 (1,8) 2.3 (0,7) 2 (50) 2.4 (60,3) 3.2 (1,0) 1.6 (0,5) 8.0 (2,5) 3.2 (1,0) 2-1/2 (65) 2.9 (73,0) 3.9 (1,2) 2.0 (0,6) 9.8 (3,0) 3.9 (1,2) – (65) 3.0 (76,1) 4.1 (1,2) 2.1 (0,6) 10.3 (3,1) 4.1 (1,2) 3 (80) 3.5 (88,9) 4.9 (1,5) 2.4 (0,7) 12.2 (3,7) 4.9 (1,5) 4 (100) 4.5 (114,3) 6.5 (2,0) 3.3 (1,0) 16.3 (5,0) 6.5 (2,0) – (125) 5.5 (139,7) 8.0 (2,4) 4.1 (1,3) 20.0 (6,1) 8.0 (2,4) 5 (125) 5.6 (141,3) 8.2 (2,5) 4.1 (1,3) 20.5 (6,3) 8.2 (2,5) – (150) 6.5 (165,1) 9.5 (2,9) 4.8 (1,4) 23.8 (7,2) 9.5 (2,9) 6 (150) 6.6 (168,3) 9.9 (3,0) 5.0 (1,5) 24.8 (7,6) 9.9 (3,0) 8 (200) 8.6 (219,1) 13.1 (4,0) 6.6 (2,0) 32.8 (10,0) 13.1 (4,0) 10 (250) 10.8 (273,0) 16.5 (5,0) 8.3 (2,5) 41.3 (12,6) 16.5 (5,0) 12 (300) 12.8 (323,9) 19.9 (6,1) 9.9 (3,0) 49.7 (15,1) 19.9 (6,1) 1. For the reducing tee branches, use the value that is corresponding to the branch size. Example: For 8” x 8” x 2” tee, the branch value of 2” is 8.0 feet. For sizes not listed interpolate from the values shown. TABLE A FRICTION RESISTANCE FOR FIGURES 501, 510, 510DE AND 519 (EXPRESSED AS EQUIVALENT STRAIGHT PIPE) TFP1815 Page 23 of 26 Friction Resistance Nominal Pipe Size Elbows 90° Feet (m) Elbows 45° Feet (m) Tee* Branch Feet (m) Tee Run Feet (m)ANSI Inches (DN) O.D. Inches (mm) 2 (50) 2.4 (60,3) 3.5 (1,1) 1.6 (0,5) 8.0 (2,4) 3.2 (1,0) 2-1/2 (65) 2.9 (73,0) 4.3 (1,3) 2.0 (0,6) 9.8 (3,0) 3.9 (1,2) – (65) 3.0 (76,1) 4.3 (1,3) 2.1 (0,6) 10.3 (3,1) 4.1 (1,2) 3 (80) 3.5 (88,9) 5.0 (1,5) 2.4 (0,7) 12.2 (3,7) 4.9 (1,5) 4 (100) 4.5 (114,3) 6.7 (2,0) 3.3 (1,0) 16.3 (5,0) 6.5 (2,0) – (125) 5.5 (139,7) 8.3 (2,5) 4.1 (1,2) 20.0 (6,1) 8.0 (2,4) 5 (125) 5.6 (141,3) 8.5 (2,5) 4.3 (1,3) 21.5 (6,5) 8.6 (2,6) – (150) 6.5 (165,1) 9.6 (2,9) 4.8 (1,5) 23.8 (7,3) 9.5 (2,9) 6 (150) 6.6 (168,3) 10.0 (3,0) 5.0 (1,5) 24.8 (7,6) 9.9 (3,0) 8 (200) 8.6 (219,1) 13.1 (4,0) 6.6 (2,0) 32.8 (10,0) 13.0 (4,0) TABLE B FRICTION RESISTANCE FOR FIGURES 510S AND 519S (EXPRESSED AS EQUIVALENT LENGTH OF STRAIGHT SCHEDULE 40 STEEL PIPE) TFP1815 Page 24 of 26 Nominal Pipe Size Figure 501 Cast 45° Elbow psi bar Figure 510 Cast 90° Elbow psi bar Figure 519 Cast Tee psi bar Ansi Inches (DN) O.D. Inches mm UL FM VdS LPCB UL FM VdS LPCB UL FM VdS LPCB 1 (25) 1.31 (33,4)———————————— 1-1/4 (32) 1.66 (42,4)————365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0)—365 (25,2) 232 (16,0) 290 (20,0) 1-1/2 (40) 1.90 (48,3)————365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0)—365 (25,2) 232 (16,0) 290 (20,0) 2 (50) 2.37 (60,3) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 2-1/2 (65) 2.87 (73,0) 365 (25,2) 365 (25,2)——365 (25,2) 365 (25,2)——365 (25,2) 365 (25,2)—— 76,1mm (65) 3.00 (76,1) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 3 (80) 3.50 (88,9) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 4 (100) 4.50 (114,3) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 139,1mm (125) 5.50 (139,7) 365 (25,2) 365 (25,2) 232 (16,0)—365 (25,2) 365 (25,2) 232 (16,0)—365 (25,2) 365 (25,2) 232 (16,0)— 5 (125) 5.56 (141,3)—365 (25,2)———365 (25,2)———365 (25,2)—— 165,1mm (150) 6.50 (165,1) 365 (25,2) 365 (25,2)—290 (20,0) 365 (25,2) 365 (25,2)—290 (20,0) 365 (25,2) 365 (25,2)—290 (20,0) 6 (150) 6.63 (168,3) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 8 (200) 8.63 (219,1) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 10 (250) 10.75 (273,0)———————————— 12 (300) 12.75 (323,9)———————————— TABLE C FIGURE 501 AND FIGURE 510 CAST ELBOWS, AND 519 CAST TEE LISTED/APPROVED PRESSURE RATING TFP1815 Page 25 of 26 Nominal Pipe Size Figure 260 Cast End Cap psi bar Figure 510S Cast 90° Elbow psi bar Figure 519S Cast Tee psi bar Ansi Inches (DN) O.D. Inches (mm) UL FM VdS LPCB UL FM VdS LPCB UL FM VdS LPCB 1 (25) 1.31 (33,4) 500 (34,5)——————————— 1-1/4 (32) 1.66 (42,4) 500 (34,5) 500 (34,5)—————————— 1-1/2 (40) 1.90 (48,3) 500 (34,5) 500 (34,5)—————————— 2 (50) 2.37 (60,3) 500 (34,5) 500 (34,5)——365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 2-1/2 (65) 2.87 (73,0) 500 (34,5) 500 (34,5)——365 (25,2) 365 (25,2)——365 (25,2) 365 (25,2)—— 76,1mm (65) 3.00 (76,1) 500 (34,5) 500 (34,5)——365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 365 (25,2) 365 (25,2)—290 (20,0) 3 (80) 3.50 (88,9) 500 (34,5) 500 (34,5)——365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 4 (100) 4.50 (114,3) 500 (34,5) 500 (34,5)——365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 139,1mm (125) 5.50 (139,7) 500 (34,5) 500 (34,5)——365 (25,2) 365 (25,2) 232 (16,0)—365 (25,2) 365 (25,2) 232 (16,0)— 5 (125) 5.56 (141,3) 500 (34,5) 500 (34,5)———365 (25,2)———365 (25,2)—— 165,1mm (150) 6.50 (165,1) 500 (34,5) 500 (34,5)——365 (25,2) 365 (25,2)——365 (25,2) 365 (25,2)—— 6 (150) 6.63 (168,3) 500 (34,5) 500 (34,5)——365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 8 (200) 8.63 (219,1) 500 (34,5) 500 (34,5)——365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 365 (25,2) 365 (25,2) 232 (16,0) 290 (20,0) 10 (250) 10.75 (273,0) 500 (34,5) 500 (34,5)—————————— 12 (300) 12.75 (323,9) 500 (34,5) 500 (34,5)—————————— TABLE D FIGURE 260 CAST END CAP, FIGURE 510S CAST ELBOW, AND FIGURE 519S CAST TEE LISTED/APPROVED PRESSURE RATING GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP1815 Page 26 of 26 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. Ordering Procedure GRINNELL Products are available glob- ally through a network of distribution centers. For the nearest distributor, visit www.grinnell.com. When placing an order, indicate the full product name. Please specify the quantity, figure number, wall thickness, and size. Nominal Pipe Size ADACAP psi bar Inches x NPT (DN)UL FM VdS LPCB 1-1/2 x 1/2 (40) 300 (20,7) 300 (20,7)—— 1-1/2 x 3/4 (40) 300 (20,7) 300 (20,7)—— 1-1/2 x 1 (40) 300 (20,7) 300 (20,7)—— 2 x 1/2 (50) 300 (20,7) 300 (20,7)—— 2 x 3/4 (50) 300 (20,7) 300 (20,7)—— 2 x 1 (50) 300 (20,7) 300 (20,7)—— 2-1/2 x 1/2 (65) 300 (20,7) 300 (20,7)—— 2-1/2 x 3/4 (65) 300 (20,7) 300 (20,7)—— 2-1/2 x 1 (65) 300 (20,7) 300 (20,7)—— TABLE E ADACAP LISTED/APPROVED PRESSURE RATING Grinnell Grooved Fire Protection Products Figure 730 Mechanical Tees - Threaded / Grooved Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 www.tyco-fire.com September 2004 TFP1860Page 1 of 4 The Figure 730 Mechanical Tees may be used for any tee connection where a threaded or grooved outlet is needed. They may be converted into a cross when necessary. WARNING The Figure 730 Mechanical Tee described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Figure: 730 Outlet: Threaded or Grooved Approvals: UL, FM, ULC, VdS, and LPCB; See Fire Protection Submittal Sheet for exact Listing / Approval information. Housing:Ductile iron conforming to ASTM A-536, Grade 65-45-12 General Description When placing an order, indicate the full product name. Please specify the quantity, figure number, type of gasket, Grade “E” EPDM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Ordering Procedure Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products’ sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer’s representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS’ LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Limited Warranty See Fire Protection Submittal Sheet for Pressure Rating and Listing/Approval Information LPCB Vd S Protective Coatings: • Non-lead orange paint • Fire brigade red (optional) non-lead paint • Hot dipped galvanized conforming to ASTM A-153 Bolt/Nuts: Track Head Bolts - conforming to ASTM A-183, Zinc Plated, (Min. Tensile = 110,000 psi/758,422 kPa) Metric - conforming to ASTM F568M Gasket: (specify when ordering) • Grade “E” EPDM, green color code (See Data Sheet TFP1895 for aid in selecting proper gasket) Technical Data Page 2 of 4 TFP1860 Figure 730 Mechanical Outlet Tee (Threaded) Figure 730 Mechanical Outlet Cross (Threaded) B A A C D TAKEOUT D TAKEOUT B A E D TAKEOUT C Figure 730 Mechanical Outlet Tee and Cross (Threaded) ‡ Proper hole preparation is required for effective sealing and performance. Check the pipe seal surface within 5/8" of the hole to be certain it is free from conditions that would affect proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact area, that might affect assembly, proper seating of the locating collar or flow from the outlet. Check gasket grade to be certain it is suitable for the service. For crosses, ensure double outlet holes are aligned on opposite sides of the pipe. The use of threaded products other than steel pipe, such as dry pendents, etc. may not be compatible with the female threaded outlet on the Mechanical Tee. Always confirm compatibility by contacting Tyco Fire Products. ** Gold color coded metric bolt sizes are available upon request. Note: Outlet threads conforming to ISO 7-1 are available, contact Tyco Fire Products for details. Nom. Size Hole Dia.‡ Nominal Dimensions Tee Cross Hole Max. A B C D E Net Wt. Net Wt. Run x Branch Inches Inches Inches Inches Inches Inches Inches Lbs. Lbs. mm mm mm mm mm mm mm Kg. Kg. 1.50 1.63 2.62 4.88 3.07 2.12 1.59 3/8" x 21/4" 2.2 2.6 38.1 41.3 66.5 124.0 78.0 53.8 40.4 M10 x 57 1.0 1.2 1.75 1.88 2.78 4.88 3.32 1.93 1.59 3/8" x 21/4" 2.5 3.3 44.5 47.6 70.6 124.0 84.3 49.0 40.4 M10 x 57 1.1 1.5 1.75 1.88 2.75 4.88 3.32 1.93 1.59 3/8" x 21/4" 2.5 3.7 44.5 47.6 69.9 124.0 84.3 49.0 40.4 M10 x 57 1.1 1.7 1.50 1.63 2.88 5.25 3.07 2.38 1.81 3/8" x 21/4" 2.7 3.1 38.1 41.3 73.2 133.4 78.0 60.5 46.0 M10 x 57 1.2 1.4 2.00 2.13 3.00 5.25 3.56 2.19 1.81 3/8" x 21/4" 3.1 3.9 50.8 54.0 76.2 133.4 90.4 55.6 46.0 M10 x 57 1.4 1.8 2.00 2.13 3.07 5.25 3.59 2.17 1.81 3/8" x 21/4" 3.3 4.3 50.8 54.0 78.0 133.4 91.2 55.1 46.0 M10 x 57 1.5 1.9 2.00 2.13 3.19 5.25 4.00 2.44 1.81 3/8" x 21/4" 3.5 4.4 50.8 54.0 81.0 133.4 101.6 62.0 46.0 M10 x 57 1.6 2.0 1.50 1.63 2.94 5.62 3.07 2.44 1.87 2.7 3.1 38.1 41.3 74.5 142.7 78.0 62.0 47.5 1.2 1.4 2.00 2.13 3.06 5.62 3.56 2.25 1.87 3.1 3.9 50.8 54.0 77.7 142.7 90.4 57.2 47.5 1.4 1.8 2.00 2.13 3.13 5.62 3.56 2.25 1.87 3.3 5.1 50.8 54.0 79.5 142.7 90.4 57.2 47.5 1.5 2.3 2.50 2.63 3.25 5.62 4.00 2.50 1.87 4.1 5.9 63.5 66.7 82.6 142.7 101.6 63.5 47.5 1.9 2.7 1.50 1.63 3.19 6.13 3.07 2.56 2.21 1/2" x 3" 3.7 4.5 38.1 41.3 81.0 155.7 78.0 65.0 56.1 M12 x 76 1.7 2.0 1.75* 1.88 3.34 6.13 3.32 2.50 2.21 1/2" x 3" 3.9 4.9 44.5 47.6 84.8 155.7 84.3 63.5 56.1 M12 x 76 1.8 2.2 2.00 2.13 3.38 6.13 3.56 2.48 2.21 1/2" x 3" 4.2 5.5 50.8 54.0 85.9 155.7 90.4 63.0 56.1 M12 x 76 1.9 2.5 2.50 2.63 3.50 6.13 4.09 2.75 2.21 1/2" x 3" 4.7 6.5 63.5 66.7 88.9 155.7 103.9 69.9 56.1 M12 x 76 2.1 2.9 1.50 1.63 3.69 7.13 3.07 3.06 2.78 1/2" x 3" 5.5 7.1 38.1 41.3 93.7 181.1 78.0 77.7 70.6 M12 x 76 2.5 3.2 1.75* 1.88 3.92 7.13 3.32 3.00 2.78 1/2" x 3" 5.5 7.1 44.5 47.6 99.6 181.1 84.3 76.2 70.6 M12 x 76 2.5 3.2 2.00 2.13 4.00 7.13 3.56 2.98 2.78 1/2" x 3" 5.5 7.1 50.8 54.0 101.6 181.1 90.4 75.7 70.6 M12 x 76 2.5 3.2 2.50 2.63 4.00 7.13 4.06 3.25 2.78 1/2" x 3" 6.0 8.1 63.5 66.7 101.6 181.1 103.1 82.6 70.6 M12 x 76 2.7 3.7 2.75 2.88 4.00 7.13 4.38 3.12 2.78 1/2" x 3" 6.0 8.1 69.9 73.0 101.6 181.1 111.3 79.2 70.6 M12 x 76 2.7 3.7 2.75 2.88 4.00 7.13 4.38 3.12 2.78 6.0 8.1 69.9 73.0 101.6 181.1 111.3 79.2 70.6 2.7 3.7 3.50 3.63 4.13 7.13 5.13 3.31 2.78 1/2" x 3" 7.0 13.5 88.9 92.1 104.9 181.1 130.3 84.1 70.6 M12 x 76 3.2 6.1 2" x 1/2", 3/4", 1" 2" x 11/4" 2" x 11/2" 21/2" x 1/2", 3/4", 1" 21/2" x 11/4" 21/2" x 11/2" 21/2" x 2" 76.1mm x 1/2", 3/4", 1" 76.1mm x 11/4" 76.1mm x 11/2" 76.1mm x 2" 3" x 1/2", 3/4", 1" 3" x 11/4" 3" x 11/2" 3" x 2" 4" x 1/2", 3/4", 1" 4" x 11/4" 4" x 11/2" 4" x 2" 4" x 21/2" 4" x 76.1mm 4" x 3" Bolt Size** Dia. x Lg. M10 x 57 M10 x 57 M10 x 57 M10 x 57 M12 x 76 Page 3 of 4 TFP1860 ‡ Proper hole preparation is required for effective sealing and performance. Check the pipe seal surface within 5/8" of the hole to be certain it is free from conditions that would affect proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact area, that might affect assembly, proper seating of the locating collar or flow from the outlet. Check gasket grade to be certain it is suitable for the service. For crosses, ensure double outlet holes are aligned on opposite sides of the pipe. The use of threaded products other than steel pipe, such as dry pendents, etc. may not be compatible with the female threaded outlet on the Mechanical Tee. Always confirm compatibility by contacting Tyco Fire Products. ** Gold color coded metric bolt sizes are available upon request. Note: Outlet threads conforming to ISO 7-1 are available, contact Tyco Fire Products for details. Figure 730 Mechanical Outlet Tee and Cross (Threaded) Figure 730 Mechanical Outlet Tee (Threaded) Figure 730 Mechanical Outlet Cross (Threaded) B A A C D TAKEOUT D TAKEOUT B A E D TAKEOUT C Nom. Size Hole Dia.‡ Nominal Dimensions Tee Cross Hole Max. A B C D E Net Wt. Net Wt. Run x Branch Inches Inches Inches Inches Inches Inches Inches Lbs. Lbs. mm mm mm mm mm mm mm Kg. Kg. 2.00 2.13 4.63 8.13 3.56 4.00 3.37 5/8" x 43/4" 6.5 7.7 50.8 54.0 117.6 206.5 90.4 101.6 85.6 M16 x 121 2.9 3.5 2.50 2.63 4.63 8.13 4.06 3.88 3.37 5/8" x 43/4" 7.1 8.1 63.5 66.7 117.6 206.5 103.1 98.6 85.6 M16 x 121 3.2 3.7 2.75 2.88 4.75 8.13 4.38 3.88 3.37 5/8" x 43/4" 7.3 8.7 69.9 73.0 120.7 206.5 111.3 98.6 85.6 M16 x 121 3.3 3.9 2.75 2.88 4.75 8.13 4.38 3.88 3.37 7.3 8.7 69.9 73.0 120.7 206.5 111.3 98.6 85.6 3.3 3.9 3.50 3.63 5.00 8.13 5.13 4.06 3.37 5/8" x 43/4" 7.6 14.7 88.9 92.1 127.0 206.5 130.3 103.1 85.6 M16 x 121 3.4 6.7 2.00 2.13 5.13 9.25 3.56 4.25 3.90 6.9 7.9 50.8 54.0 130.3 235.0 90.4 108.0 99.1 3.1 3.6 2.00 2.13 5.13 9.25 3.56 4.04 3.90 7.4 8.9 50.8 54.0 130.3 235.0 90.4 102.6 99.1 3.4 4.0 2.50 2.63 5.13 9.25 4.06 4.31 3.90 7.5 8.9 63.5 66.7 130.3 235.0 103.1 109.5 99.1 3.4 4.0 2.75 2.88 5.13 9.25 4.38 4.18 3.90 7.5 11.1 69.9 73.0 130.3 235.0 111.3 106.2 99.1 3.4 5.0 2.75 2.88 5.13 9.25 4.38 4.18 3.90 7.5 11.1 69.9 73.0 130.3 235.0 111.3 106.2 99.1 3.4 5.0 3.50 3.63 5.50 9.25 5.13 4.37 3.90 9.5 14.1 88.9 92.1 139.7 235.0 130.3 111.0 99.1 4.3 6.4 4.50 4.63 5.38 9.25 6.13 4.56 3.90 10.0 20.1 114.3 117.5 136.7 235.0 155.7 115.8 99.1 4.5 9.1 2.00 2.13 5.13 9.25 3.56 4.25 3.90 5/8" x 43/4" 6.9 7.9 50.8 54.0 130.3 235.0 90.4 108.0 99.1 M16 x 121 3.1 3.6 2.00 2.13 5.13 9.25 3.56 4.04 3.90 5/8" x 43/4" 7.4 8.9 50.8 54.0 130.3 235.0 90.4 102.6 99.1 M16 x 121 3.4 4.0 2.50 2.63 5.13 9.25 4.06 4.31 3.90 5/8" x 43/4" 7.5 8.9 63.5 66.7 130.3 235.0 103.1 109.5 99.1 M16 x 121 3.4 4.0 2.75 2.88 5.13 9.25 4.38 4.18 3.90 5/8" x 43/4" 7.5 11.1 69.9 73.0 130.3 235.0 111.3 106.2 99.1 M16 x 121 3.4 5.0 2.75 2.88 5.13 9.25 4.38 4.18 3.90 7.5 11.1 69.9 73.0 130.3 235.0 111.3 106.2 99.1 3.4 5.0 3.50 3.63 5.50 9.25 5.13 4.37 3.90 5/8" x 43/4" 9.5 14.1 88.9 92.1 139.7 235.0 130.3 111.0 99.1 M16 x 121 4.3 6.4 4.50 4.63 5.38 9.25 6.13 4.56 3.90 5/8" x 43/4" 10.0 20.1 114.3 117.5 136.7 235.0 155.7 115.8 99.1 M16 x 121 4.5 9.1 2.75 2.88 6.25 12.50 4.38 5.12 4.90 3/4" x 43/4" 10.2 12.1 69.9 73.0 158.8 317.5 111.3 130.0 124.5 M20 x 121 4.6 5.5 2.75 2.88 6.25 12.50 4.38 5.12 4.90 10.2 12.1 69.9 73.0 158.8 317.5 111.3 130.0 124.5 4.6 5.5 3.50 3.63 6.50 12.50 5.13 5.37 4.90 3/4" x 43/4" 12.5 15.1 88.9 92.1 165.1 317.5 130.3 136.4 124.5 M20 x 121 5.7 6.8 4.50 4.63 6.38 12.50 6.13 5.56 4.90 3/4" x 43/4" 12.5 21.1 114.3 117.5 162.1 317.5 155.7 141.2 124.5 M20 x 121 5.7 9.6 5" x 11/2" 5" x 2" 5" x 21/2" 5" x 76.1mm 5" x 3" 165.1mm x 11/4" 165.1mm x 11/2" 165.1mm x 2" 165.1mm x 21/2" 165.1mm x 76.1mm 165.1mm x 3" 165.1mm x 4" 6" x 11/4" 6" x 11/2" 6" x 2" 6" x 21/2" 6" x 76.1mm 6" x 3" 6" x 4" 8" x 21/2" 8" x 76.1mm 8" x 3" 8" x 4" Bolt Size** Dia. x Lg. M16 x 121 M16 x 121 M16 x 121 M16 x 121 M16 x 121 M16 x 121 M16 x 121 M16 x 121 M16 x 121 M20 x 121 General Notes: It is the Designer’s responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (IH-1000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application.Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. Page 4 of 4 TFP1860 Figure 730 Mechanical Outlet Tee and Cross (Grooved) ‡ Proper hole preparation is required for effective sealing and performance. Check the pipe seal surface within 5/8" of the hole to be certain it is free from conditions that would affect proper gasket sealing. Remove any sharp or rough edges from the hole or upper housing contact area, that might affect assembly, proper seating of the locating collar or flow from the outlet. Check gasket grade to be certain it is suitable for the service. For crosses, ensure double outlet holes are aligned on opposite sides of the pipe. The use of threaded products other than steel pipe, such as dry pendents, etc. may not be compatible with the female threaded outlet on the Mechanical Tee. Always confirm compatibility by contacting Tyco Fire Products. ** Gold color coded metric bolt sizes are available upon request. B A A C Figure 730 Mechanical Outlet Grooved Cross Figure 730 Mechanical Outlet Grooved Tee A E B C Nominal Hole Dia.‡ Nominal Dimensions Tee Cross Size Hole Max. A B C E Net Wt. Net Wt. Run x Inches Inches Inches Inches Inches Inches Lbs. Lbs. Branch mm mm mm mm mm mm Kg. Kg. 1.75 1.88 2.78 4.88 3.32 1.59 3/8" x 21/4" 2.5 3.3 44.5 47.6 70.6 124.0 84.3 40.4 M10 x 57 1.1 1.5 1.75 1.88 2.62 4.88 3.32 1.59 3/8" x 21/4" 2.5 3.7 44.5 47.6 66.5 124.0 84.3 40.4 M10 x 57 1.1 1.7 2.00 2.13 3.00 5.25 3.56 1.81 3/8" x 21/4" 3.1 3.9 50.8 54.0 76.2 133.4 90.4 46.0 M10 x 57 1.4 1.8 2.00 2.13 3.07 5.25 3.59 1.81 3/8" x 21/4" 3.3 4.3 50.8 54.0 78.0 133.4 91.2 46.0 M10 x 57 1.5 1.9 2.00 2.13 3.19 5.25 4.00 1.81 3/8" x 21/4" 3.5 4.4 50.8 54.0 81.0 133.4 101.6 46.0 M10 x 57 1.6 2.0 2.00 2.13 3.06 5.62 3.56 1.87 3.1 3.9 50.8 54.0 77.7 142.7 90.4 47.5 1.4 1.8 2.00 2.13 3.13 5.62 3.56 1.87 3.3 5.1 50.8 54.0 79.5 142.7 90.4 47.5 1.5 2.3 2.50 2.63 3.25 5.62 4.00 1.87 4.1 5.9 63.5 66.7 82.6 142.7 101.6 47.5 1.9 2.7 1.75* 1.88 3.34 6.13 3.32 2.21 1/2" x 3" 3.9 4.9 44.5 47.6 84.8 155.7 84.3 56.1 M12 x 76 1.8 2.2 2.00 2.13 3.38 6.13 3.56 2.21 1/2" x 3" 4.2 5.5 50.8 54.0 85.9 155.7 90.4 56.1 M12 x 76 1.9 2.5 2.50 2.63 3.50 6.13 4.09 2.21 1/2" x 3" 4.7 6.5 63.5 66.7 88.9 155.7 103.9 56.1 M12 x 76 2.1 2.9 1.75* 1.88 3.92 7.13 3.32 2.78 1/2" x 3" 5.5 7.1 44.5 47.6 99.6 181.1 84.3 70.6 M12 x 76 2.5 3.2 2.00 2.13 4.00 7.13 3.56 2.78 1/2" x 3" 5.5 7.1 50.8 54.0 101.6 181.1 90.4 70.6 M12 x 76 2.5 3.2 2.50 2.63 4.00 7.13 4.06 2.78 1/2" x 3" 6.0 8.1 63.5 66.7 101.6 181.1 103.1 70.6 M12 x 76 2.7 3.7 2.75 2.88 4.00 7.13 4.38 2.78 1/2" x 3" 6.0 8.1 69.9 73.0 101.6 181.1 111.3 70.6 M12 x 76 2.7 3.7 2.75 2.88 4.00 7.13 4.38 2.78 6.0 8.1 69.9 73.0 101.6 181.1 111.3 70.6 2.7 3.7 3.50 3.63 4.13 7.13 5.13 2.78 1/2" x 3" 7.0 13.5 88.9 92.1 104.9 181.1 130.3 70.6 M12 x 76 3.2 6.1 2.00 2.13 4.63 8.13 3.56 3.37 5/8" x 43/4" 6.5 7.7 50.8 54.0 117.6 206.5 90.4 85.6 M16 x 121 2.9 3.5 2.50 2.63 4.63 8.13 4.06 3.37 5/8" x 43/4" 7.1 8.1 63.5 66.7 117.6 206.5 103.1 85.6 M16 x 121 3.2 3.7 2.75 2.88 4.75 8.13 4.38 3.37 5/8" x 43/4" 7.3 8.7 69.9 73.0 120.7 206.5 111.3 85.6 M16 x 121 3.3 3.9 2" x 11/4" 2" x 11/2" 21/2" x 11/4" 21/2" x 11/2" 21/2" x 2" 76.1mm x 11/4" 76.1mm x 11/2" 76.1mm x 2" 3" x 11/4" 3" x 11/2" 3" x 2" 4" x 11/4" 4" x 11/2" 4" x 2" 4" x 21/2" 4" x 76.1mm 4" x 3" 5" x 11/2" 5" x 2" 5" x 21/2" Bolt Size** Dia. x Lg. M10 x 57 M10 x 57 M10 x 57 M12 x 76 Nominal Hole Dia.‡ Nominal Dimensions Tee Cross Size Hole Max. A B C E Net Wt. Net Wt. Run x Inches Inches Inches Inches Inches Inches Lbs. Lbs. Branch mm mm mm mm mm mm Kg. Kg. 2.75 2.88 4.75 8.13 4.38 3.37 7.3 8.7 69.9 73.0 120.7 206.5 111.3 85.6 3.3 3.9 3.50 3.63 5.00 8.13 5.13 3.37 5/8" x 43/4" 7.6 14.7 88.9 92.1 127.0 206.5 130.3 85.6 M16 x 121 3.4 6.7 2.00 2.13 5.13 9.25 3.56 3.90 6.9 7.9 50.8 54.0 130.3 235.0 90.4 99.1 3.1 3.6 2.00 2.13 5.13 9.25 3.56 3.90 7.4 8.9 50.8 54.0 130.3 235.0 90.4 99.1 3.4 4.0 2.50 2.63 5.13 9.25 4.06 3.90 7.5 8.9 63.5 66.7 130.3 235.0 103.1 99.1 3.4 4.0 2.75 2.88 5.13 9.25 4.38 3.90 7.5 11.1 69.9 73.0 130.3 235.0 111.3 99.1 3.4 5.0 2.75 2.88 5.13 9.25 4.38 3.90 7.5 11.1 69.9 73.0 130.3 235.0 111.3 99.1 3.4 5.0 3.50 3.63 5.50 9.25 5.13 3.90 9.5 14.1 88.9 92.1 139.7 235.0 130.3 99.1 4.3 6.4 4.50 4.63 5.38 9.25 6.13 3.90 10.0 20.1 114.3 117.5 136.7 235.0 155.7 99.1 4.5 9.1 2.00 2.13 5.13 9.25 3.56 3.90 5/8" x 43/4" 6.9 7.9 50.8 54.0 130.3 235.0 90.4 99.1 M16 x 121 3.1 3.6 2.00 2.13 5.13 9.25 3.56 3.90 5/8" x 43/4" 7.4 8.9 50.8 54.0 130.3 235.0 90.4 99.1 M16 x 121 3.4 4.0 2.50 2.63 5.13 9.25 4.06 3.90 5/8" x 43/4" 7.5 8.9 63.5 66.7 130.3 235.0 103.1 99.1 M16 x 121 3.4 4.0 2.75 2.88 5.13 9.25 4.38 3.90 5/8" x 43/4" 7.5 11.1 69.9 73.0 130.3 235.0 111.3 99.1 M16 x 121 3.4 5.0 2.75 2.88 5.13 9.25 4.38 3.90 7.5 11.1 69.9 73.0 130.3 235.0 111.3 99.1 3.4 5.0 3.50 3.63 5.50 9.25 5.13 3.90 5/8" x 43/4" 9.5 14.1 88.9 92.1 139.7 235.0 130.3 99.1 M16 x 121 4.3 6.4 4.50 4.63 5.38 9.25 6.13 3.90 5/8" x 43/4" 10.0 20.1 114.3 117.5 136.7 235.0 155.7 99.1 M16 x 121 4.5 9.1 2.75 2.88 6.25 12.50 4.38 4.90 3/4" x 43/4" 10.2 12.1 69.9 73.0 158.8 317.5 111.3 124.5 M20 x 121 4.6 5.5 2.75 2.88 6.25 12.50 4.38 4.90 10.2 12.1 69.9 73.0 158.8 317.5 111.3 124.5 4.6 5.5 3.50 3.63 6.50 12.50 5.13 4.90 3/4" x 43/4" 12.5 15.1 88.9 92.1 165.1 317.5 130.3 124.5 M20 x 121 5.7 6.8 4.50 4.63 6.38 12.50 6.13 4.90 3/4" x 43/4" 12.5 21.1 114.3 117.5 162.1 317.5 155.7 124.5 M20 x 121 5.7 9.6 5" x 76.1mm 5" x 3" 165.1mm x 11/4" 165.1mm x 11/2" 165.1mm x 2" 165.1mm x 21/2" 165.1mm x 76.1mm 165.1mm x 3" 165.1mm x 4" 6" x 11/4" 6" x 11/2" 6" x 2" 6" x 21/2" 6" x 76.1mm 6" x 3" 6" x 4" 8" x 21/2" 8" x 76.1mm 8" x 3" 8" x 4" Bolt Size** Dia. x Lg. M16 x 121 M16 x 121 M16 x 121 M16 x 121 M16 x 121 M16 x 121 M16 x 121 M16 x 121 M16 x 121 M20 x 121 PROJECT INFORMATION APPROVAL STAMP Project:TApproved Address:TApproved as noted Contractor:TNot approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3201 90˚ Elbow For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A A FIGURE 3201 - 90° ELBOW Nominal Size Maximum Working Pressure▲Dimension A Approx. Wt. Each In. (mm) PSI (kPa) In. (mm) Lbs. (kg) 1 500 1.50 0.62 20 3450 38.10 0.28 11⁄4 500 1.75 0.90 32 3450 44.45 0.41 11⁄2 500 1.94 1.20 40 3450 49.276 0.54 2 500 2.25 1.85 50 3450 57.15 0.84 ▲ – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Note - fittings are not of domestic manufacture as specified in contract drawings. PROJECT INFORMATION APPROVAL STAMP Project:TApproved Address:TApproved as noted Contractor:TNot approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3202 45˚ Elbow For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A AFIGURE 3202 - 45° ELBOW Nominal Size Maximum Working Pressure▲Dimension A Approx. Wt. Each In. (mm) PSI (kPa) In. (mm) Lbs. (kg) 1 500 1.12 0.46 25 3450 28.44 0.21 11⁄4 500 1.29 0.73 32 3450 32.76 0.33 11⁄2 500 1.43 0.92 40 3450 36.32 0.42 2 500 1.68 1.50 50 3450 42.67 0.68 ▲ – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:TApproved Address:TApproved as noted Contractor:TNot approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.14 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3283 Bushings For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIGURE 3283 - BUSHINGS Nominal Size Max. Working Pressure▲ Dimensions Style Approx. Wt. EachMale (M) x Female (F) A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 1 x 1⁄2 500 0.75 0.25 1.42 Outside 0.22 25 x 15 3450 19.05 6.35 36.06 0.10 1 x 3⁄4 500 0.75 0.25 1.42 Outside 0.17 25 x 20 3450 19.05 6.35 36.06 0.08 11⁄4 x 1 500 0.80 0.28 1.76 Outside 0.28 32 x 25 3450 20.32 7.11 44.70 0.13 11⁄2 x 1 500 0.83 0.31 2.00 Outside 0.45 40 x 25 3450 21.08 7.874 50.80 0.20 11⁄2 x 11⁄4 500 0.83 0.31 2.00 Outside 0.30 40 x 32 3450 21.08 7.874 50.80 0.14 2 x 1 500 0.88 0.41 1.95 Inside 0.67 50 x 25 3450 22.35 10.414 49.53 0.30 2 x 11⁄4 500 0.88 0.34 2.48 Outside 0.73 50 x 32 3450 22.35 8.636 62.99 0.33 2 x 11⁄2 500 0.88 0.34 2.48 Outside 0.61 50 x 40 3450 22.35 8.636 62.99 0.28 ▲ – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. A B C Inside Head A B C Inside Head M F A B C Outside Head A B C Outside Head M F PROJECT INFORMATION APPROVAL STAMP Project:TApproved Address:TApproved as noted Contractor:TNot approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3224 Cap For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A FIGURE 3224 - CAP Nominal Size Maximum Working Pressure▲Dimension A Approx. Wt. Each In. (mm) PSI (kPa) In. (mm) Lbs. (kg) 1 500 1.16 0.32 25 3450 29.46 0.15 11⁄4 500 1.28 0.43 32 3450 32.51 0.20 11⁄2 500 1.33 0.60 40 3450 33.78 0.27 2 500 1.45 0.91 50 3450 36.83 0.41 ▲ – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:TApproved Address:TApproved as noted Contractor:TNot approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3221 Coupling For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A FIGURE 3221 - COUPLING Nominal Size Maximum Working Pressure▲Dimension A Approx. Wt. Each In. (mm) PSI (kPa) In. (mm) Lbs. (kg) 1 500 1.67 0.40 25 3450 42.42 0.18 11⁄4 500 1.93 0.57 32 3450 49.02 0.26 11⁄2 500 2.15 0.75 40 3450 54.61 0.34 2 500 2.53 1.15 50 3450 64.26 0.52 ▲ – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:TApproved Address:TApproved as noted Contractor:TNot approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3201R Reducing 90˚ Elbow For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIGURE 3201R - REDUCING 90° ELBOW Nominal Size Max. Working Pressure▲ Dimensions Approx. Wt. Each1 x 2 A B In. (mm) PSI (kPa) In. (mm) In. (mm) Lbs. (kg) 1 x 1⁄2 500 1.26 1.36 0.44 25 x 15 3450 32.00 34.54 0.20 1 x 3⁄4 500 1.37 1.45 0.52 25 x 20 3450 34.79 36.83 0.24 11⁄4 x 1⁄2 500 1.34 1.53 0.64 32 x 15 34550 34.03 38.86 0.29 11⁄4 x 3⁄4 500 1.45 1.62 0.72 32 x 20 3450 36.83 41.14 0.33 11⁄4 x 1 500 1.58 1.67 0.75 32 x 25 3450 40.13 42.41 0.34 11⁄2 x 1 500 1.65 1.80 0.92 40 x 25 3450 41.91 45.72 0.42 11⁄2 x 11⁄4 500 1.82 1.88 1.08 40 x 32 3450 46.22 47.75 0.49 2 x 1⁄2 500 1.49 1.88 1.08 50 x 15 3450 37.84 47.75 0.49 2 x 3⁄4 500 1.60 1.97 1.24 50 x 20 3450 40.64 50.03 0.56 2 x 1 500 1.73 2.02 1.40 50 x 25 3450 43.94 51.30 0.64 2 x 11⁄4 500 1.90 2.10 1.52 50 x 32 3450 48.26 53.34 0.70 2 x 11⁄2 500 2.02 2.16 1.65 50 x 40 3450 51.30 54.86 0.75 ▲ – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. A B 2 1 1 x 2 PROJECT INFORMATION APPROVAL STAMP Project:TApproved Address:TApproved as noted Contractor:TNot approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3221R Reducing Coupling For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A FIGURE 3221R - REDUCING COUPLING Nominal Size Maximum Working Pressure▲Dimension A Approx. Wt. Each In. (mm) PSI (kPa) In. (mm) Lbs. (kg) 1 x 1⁄2 500 1.69 0.39 25 x 15 3450 42.92 0.18 1 x 3⁄4 500 1.69 0.53 25 x 20 3450 42.92 0.24 ▲ – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:TApproved Address:TApproved as noted Contractor:TNot approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3205R Reducing Tee For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FIGURE 3205R - REDUCING TEE Nominal Size Max. Working Pressure▲ Dimensions Approx. Wt. Each1 x 2 x 3 A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 1 x 1⁄2 x 1 500 1.50 1.36 1.50 0.64 25 x 15 x 25 3450 38.10 34.54 38.10 0.29 1 x 3⁄4 x 1 500 1.50 1.45 1.50 0.73 25 x 20 x 25 3450 38.10 36.83 38.10 0.33 1 x 1 x 1⁄2 500 1.26 1.26 1.36 0.71 25 x 25 x 15 3450 32.00 32.00 34.54 0.32 1 x 1 x 3⁄4 500 1.37 1.37 1.45 0.76 25 x 25 x 20 3450 34.80 34.80 36.83 0.34 1 x 1 x 11⁄4* 500 1.67 1.67 1.58 0.98 25 x 25 x 32 3450 42.41 42.41 40.13 0.44 1 x 1 x 11⁄2* 500 1.80 1.80 1.65 1.16 25 x 25 x 40 3450 45.72 45.72 41.91 0.53 11⁄4 x 1 x 1⁄2* 500 1.34 1.26 1.53 0.82 32 x 25 x 15 3450 34.04 32.00 38.86 0.37 11⁄4 x 1 x 3⁄4 500 1.45 1.37 1.62 0.90 32 x 25 x 20 3450 36.83 34.80 41.15 0.41 11⁄4 x 1 x 1 500 1.58 1.50 1.67 1.00 32 x 25 x 25 3450 40.13 38.10 42.42 0.45 11⁄4 x 1 x 11⁄4 500 1.75 1.67 1.75 1.08 32 x 25 x 32 3450 44.45 42.42 44.45 0.49 11⁄4 x 1 x 11⁄2 500 1.88 1.80 1.82 1.42 32 x 25 x 40 3450 47.75 45.72 46.22 0.64 11⁄4 x 11⁄4 x 1⁄2 500 1.34 1.34 1.53 0.86 32 x 32 x 15 3450 34.04 34.04 38.86 0.39 FIGURE 3205R - REDUCING TEE Nominal Size Max. Working Pressure▲ Dimensions Approx. Wt. Each1 x 2 x 3 A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 11⁄4 x 11⁄4 x 3⁄4 500 1.45 1.45 1.62 0.92 32 x 32 x 20 3450 36.83 36.83 41.15 0.42 11⁄4 x 11⁄4 x 1 500 1.58 1.58 1.67 0.95 32 x 32 x 25 3450 40.13 40.13 42.42 0.43 11⁄4 x 11⁄4 x 11⁄2* 500 1.88 1.88 1.82 1.45 32 x 32 x 40 3450 47.75 47.75 46.22 0.66 C A B 3 1 1 x 2 x 3 2 ▲ Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as "Bull Head Tee". SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS FIG. 3205R Reducing Tee FIGURE 3205R - REDUCING TEE Nominal Size Max. Working Pressure▲ Dimensions Approx. Wt. Each1 x 2 x 3 A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 11⁄2 x 11⁄2 x 2* 500 2.16 2.16 2.02 1.98 40 x 40 x 50 3450 54.86 54.86 51.30 0.90 2 x 1 x 2 500 2.25 2.02 2.25 2.15 50 x 25 x 50 3450 57.15 51.31 57.15 0.98 2 x 11⁄4 x 2 500 2.25 2.10 2.25 2.30 50 x 32 x 50 3450 57.15 53.34 57.15 1.04 2 x 11⁄2 x 1⁄2 500 1.49 1.41 1.88 1.50 50 x 40 x 15 3450 37.85 35.81 47.75 0.68 2 x 11⁄2 x 3⁄4 500 1.60 1.52 1.97 1.62 50 x 40 x 20 3450 40.64 38.61 50.04 0.73 2 x 11⁄2 x 1 500 1.73 1.65 2.02 1.64 50 x 40 x 25 3450 43.94 41.91 51.31 0.74 2 x 11⁄2 x 11⁄4 500 1.90 1.82 2.10 1.80 50 x 40 x 32 3450 48.26 46.23 53.34 0.82 2 x 11⁄2 x 11⁄2 500 2.02 1.94 2.16 2.00 50 x 40 x 40 3450 51.31 49.28 54.86 0.91 2 x 11⁄2 x 2 500 2.25 2.16 2.25 2.35 50 x 40 x 50 3450 57.15 54.86 57.15 1.07 2 x 2 x 1⁄2 500 1.49 1.49 1.88 1.60 50 x 50 x 15 3450 37.85 37.85 47.75 0.73 2 x 2 x 3⁄4 500 1.60 1.60 1.97 1.68 50 x 50 x 20 3450 40.64 40.64 50.04 0.76 2 x 2 x 1 500 1.73 1.73 2.02 1.85 50 x 50 x 25 3450 43.94 43.94 51.31 0.84 2 x 2 x 11⁄4 500 1.90 1.90 2.10 2.04 50 x 50 x 32 3450 44.45 42.42 44.45 0.93 2 x 2 x 11⁄2 500 2.02 2.02 2.16 2.18 50 x 50 x 40 3450 44.45 42.42 44.45 0.99 FIGURE 3205R - REDUCING TEE Nominal Size Max. Working Pressure▲ Dimensions Approx. Wt. Each1 x 2 x 3 A B C In. (mm) PSI (kPa) In. (mm) In. (mm) In. (mm) Lbs. (kg) 11⁄4 x 11⁄4 x 2* 500 2.10 2.10 1.90 1.75 32 x 32 x 50 3450 53.34 53.34 48.26 0.79 11⁄2 x 1 x 1⁄2 500 1.41 1.34 1.66 0.95 40 x 25 x 15 3450 35.81 34.04 42.16 0.43 11⁄2 x 1 x 3⁄4 500 1.52 1.37 1.75 1.14 40 x 25 x 20 3450 38.61 34.80 44.45 0.52 11⁄2 x 1 x 1 500 1.65 1.50 1.80 1.17 40 x 25 x 25 3450 41.91 38.10 45.72 0.53 11⁄2 x 1 x 11⁄4 500 1.82 1.67 1.88 1.34 40 x 25 x 32 3450 46.23 42.42 47.75 0.61 11⁄2 x 1 x 11⁄2 500 1.94 1.80 1.94 1.45 40 x 25 x 40 3450 49.28 45.72 49.28 0.66 11⁄2 x11⁄4 x 1⁄2 500 1.41 1.34 1.66 1.05 40 x 32 x 15 3450 35.81 34.04 42.16 0.48 11⁄2 x11⁄4 x 3⁄4 500 1.52 1.45 1.75 1.15 40 x 32 x 20 3450 38.61 36.83 44.45 0.5 11⁄2 x 11⁄4 x 1 500 1.65 1.58 1.80 1.25 40 x 32 x 25 3450 41.91 40.13 45.72 0.57 11⁄2 x 11⁄4 x 2* 500 2.16 2.10 2.02 1.90 40 x 32 x 50 3450 54.86 53.34 51.30 0.86 11⁄2 x 11⁄2 x 1⁄2 500 1.41 1.41 1.16 1.15 40 x 40 x 15 3450 35.81 35.81 29.46 0.52 11⁄2 x 11⁄2 x 3⁄4 500 1.52 1.52 1.75 1.24 40 x 40 x 20 3450 38.61 38.61 44.45 0.56 11⁄2 x 11⁄2 x 1 500 1.65 1.65 1.80 1.30 40 x 40 x 25 3450 41.91 41.91 45.72 0.59 11⁄2 x 11⁄2 x 11⁄4 500 1.82 1.82 1.88 1.48 40 x 40 x 32 3450 46.23 46.23 47.75 0.67 C A B 3 1 1 x 2 x 3 2 ▲ Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as "Bull Head Tee". PROJECT INFORMATION APPROVAL STAMP Project:TApproved Address:TApproved as noted Contractor:TNot approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-1.15 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS FIG. 3205 Straight Tee For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A AA FIGURE 3205 - STRAIGHT TEE Nominal Size Maximum Working Pressure▲ Dimension A Approx. Wt. Each In. (mm) PSI (kPa) In. (mm) Lbs. (kg) 1 500 1.50 0.85 25 3450 38.10 0.39 11⁄4 500 1.75 1.22 32 3450 44.45 0.55 11⁄2 500 1.94 1.55 40 3450 49.27 0.70 2 500 2.25 2.45 50 3450 57.15 1.11 ▲ – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. PROJECT INFORMATION APPROVAL STAMP Project:TApproved Address:TApproved as noted Contractor:TNot approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. SPF/DI-5.16 DUCTILE IRON THREADED FITTINGS Dimensions: ASME B16.14 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. MATERIAL SPECIFICATIONS ▲ Pressure - Temperature Ratings in accordance with ASME B16.3 Class 150 FIG. 3388 Cored Plug For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. A FIGURE 3388 - CORED PLUG Nominal Size Maximum Working Pressure▲Dimension A Approx. Wt. Each In. (mm) PSI (kPa) In. (mm) Lbs. (kg) 1⁄2* 500 0.94 0.10 15 3450 23.87 0.05 3⁄4 500 1.07 0.17 20 3450 27.17 0.08 1 500 1.25 0.28 25 3450 31.75 0.13 11⁄4 500 1.36 0.44 32 3450 34.54 0.20 11⁄2 500 1.45 0.62 40 3450 36.83 0.28 2 500 1.56 0.91 50 3450 39.62 0.41 ▲ – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as Solid Plug. Job Name: Job Location: Engineer: Contractor: Tag: PO Number: Representative: Wholesale Distributor: This specification is provided for reference only. Conbraco Industries Inc. reserves the right to change any portion of this specification without notice and without incurring obligation to make such changes to Conbraco products previously or subsequently sold. Please visit our website @ www.apollovalves.com for the most current information. Apollo Valves / Conbraco Industries, Inc. 701 Matthews Mint-Hill Road, Matthews, NC 28105 USA www.apollovalves.com | (704) 841-6000 Not to be used to convey or dispense water for human consumption in the United States after 1/4/2014. 94A Series Full-Port Brass Ball Valve SS1001 © 03/14 Page 1 of 1 Part Number Size (in.) Dimensions (in.)Wt. (lbs.)ABCDE NPT 94A-101-01 1/4” 0.395 1.746 1.840 3.543 – 0.33 94A-102-01 3/8” 0.407 1.756 1.840 3.543 – 0.30 94A-103-01 1/2” 0.583 2.047 1.921 3.543 – 0.44 94A-104-01 3/4” 0.748 2.362 2.087 3.780 – 0.66 94A-105-01 1” 0.945 2.756 2.559 4.528 – 1.10 94A-106-01 1-1/4” 1.260 3.307 2.953 4.528 – 1.57 94A-107-01 1-1/2” 1.575 3.661 3.346 5.512 – 2.40 94A-108-01 2” 1.969 4.181 3.681 5.512 – 3.37 94A-109-01 2-1/2” 2.520 5.378 4.764 8.661 – 7.60 94A-100-01 3” 2.953 6.039 5.079 8.661 – 9.36 94A-10A-01 4” 3.898 7.386 5.866 9.606 – 16.85 SOLDER 94A-203-01 1/2” 0.583 2.047 1.839 3.543 0.630 0.38 94A-204-01 3/4” 0.748 2.748 1.996 3.780 0.878 0.64 94A-205-01 1” 0.945 3.228 2.441 4.528 1.130 0.99 94A-206-01 1-1/4” 1.260 3.819 2.854 4.528 1.378 1.40 94A-207-01 1-1/2” 1.575 4.425 3.169 5.512 1.630 2.17 94A-208-01 2” 1.969 5.315 3.449 5.512 2.130 2.97 94A-209-01 2-1/2” 2.520 6.283 4.764 8.661 2.630 6.36 94A-200-01 3” 2.953 7.150 5.079 8.661 3.130 8.32 94A-20A-01 4” 3.945 9.276 5.866 9.606 4.130 15.78 DESCRIPTION The Apollo InternationalTM 94A forged brass ball valves combine reliable operation with maximum economy. Ideal for general flow control applications including HVAC, fuelgases, and fire protection trim and drain etc. Valves include most pertinent agency approvals. FEATURES • Full-Port • Blow-out Proof Stem Design • Adjustable Stem Packing Nut • Silicone Free • 100% Factory Tested PERFORMANCE RATING • Valve Design Rating: 600 CWP (400 CWP 2-1/2” to 4”) • Temperature Range 0°F - 400°F APPROVALS • CSA: ¼”-4” NPT per ANSI Z21.15/ CGA 9.1 (1/2 psi)/CGA 3.16 (125 psi) ¼”-4” NPT per ASME B16.44 (5 psi) ½”-2” NPT per ASME B16.33 (125 psi) 2 ½”-4” NPT per ASME B16.38 (125 psi) • UL: Guides YQNZ, YRBX, YRPV, YSDT and MHKZ (1/4” - 4” NPT only) • UL 258 – VQGU Trim & Drain 175# max (1/4” – 2”) • FM: ¼”-2” per FM1140 (<175 psi) • MSS SP-11O: Ball Valves Threaded, Socket-Welding, Solder joint, Grooved and Flared Ends STANDARD MATERIALS LIST Part Name Material Body Forged Brass (Cu >57%) Retainer Forged Brass (Cu >57%) Ball Brass, Cr plated Stem Brass, Cr plated Seats PTFE Stem Packing PTFE Gland Nut Brass Friction Washer PTFE Handle Steel w/corrosion resistant plating Handle Cover PVC Handle Nut Steel w/corrosion resistant plating DIMENSIONS OPTIONAL HANDLE KITS Size Replacement Lever Handles 2-1/4” Stem Extension + Memory Stop 1/4" - 3/8" W932400 78217101 1/2" W932500 78217201 3/4" W936000 78217301 1" W932600 78217401 1-1/4" W932700 78217501 1-1/2" W932800 78217601 2" W233200 78217601 2-1/2" - 3" W932900 78217701 4" W933000 78217801 SOLDER CONNECTION (BOTH ENDS) A E C D B NPT (BOTH ENDS) B C D A