01 Upson Hall Lab 466_Drawings Indexed - inc addenda (2)
Drawing ListGeneralG-000Cover SheetG-001Code Compliance Plan & NotesArchitecturalA-000General Notes & LegendsA-101Partial Fourth Floor PlansA-102Partial Plans & Lab Equipment ScheduleA-420Interior ElevationsA-601Details & SchedulesA-602SpecificationsPlumbingP-100General Notes, Symbols List, Details & Floor Plans -PlumbingMechancialM-000General Notes and Symbols -HVACM-100Partial Fourth Floor Plans -HVACM-200Control Schematics & System SummariesM-201Control Schematics & System SummariesM-300Details & Schedules -HVACElectricalE-000Symbols List & General Notes -ElectricalE-100Partial Fourth Floor Plan -Power & Special SystemsE-101Partial Fourth Floor Plan -LightingE-200Schedules -ElectricalE-201Details -ElectricalE-202Details II -ElectricalThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:RevisionsSWBR Project #6/7/2021 1:29:12 PMBIM 360://20625.03 Cornell University Upson Hall Room 466/Upson Hall 466-ARCH-R20.rvt20625.03SDFCover SheetCREAD/CREG-000100% ConstructionDocumentsCornell UniversityUpson Hall 466 Lab RenovationIthaca, NYJune 1, 2021June 1, 2021Upson Hall 466 LabRenovation100% Construction Documents20625.03124 Hoy RdIthaca, NY 14850Architect & Structural Engineer:SWBR387 East Main StreetRochester, NY 14604585 232 8300rochester@swbr.comRegional MapLocation MapUpson HallUpson HallMechanical, Electrical, Plumbing & Fire Protection Engineer:M/E Engineering300 Trolley BlvdRochester, NY 14606585 288 5590 FEE2SEE2SEE2SEE2SEE2SEEXISTING 2HR RATED SHAFTWALL ASSEMBLYEXISTING EMERGENCY EYEWASHEXISTING ACCESSIBLE SINK (FRONT APPROACH)ADJUSTABLE HEIGHT WORKSTATIONSCOLLAPSIBLE WATER DAMPOWER-OPERATED SLIDING DOOR DASHED LINES DENOTES EMERGENCY SWING OPERATION IN EVENT OF POWER FAILUREADJUSTABLE HEIGHT WORKSTATIONS223 SFMAKER SPACE466A552 SFLAB466CLASSIFICATIONS OF BUILDING, AS SPECIFIED IN THE 2020 EDITION OF THE BUILDING CODE OF NEW YORK STATE ARE AS FOLLOWS:BUILDING DATA AND CODE COMPLIANCEBUILDING DATA:CONSTRUCTION CLASSIFICATION:BUILDING OCCUPANCY CLASSIFICATION:FIRE PROTECTION SYSTEM:RENOVATION AREA:CONTROL AREA:EXISTING FLOOR ASSEMBLY:1B (ASSUMED)B -BUSINESS, A-3 -ASSEMBLYFULLY SPRINKLERED810 SFSOUTH WING (FOURTH FLOOR)EXISTING 2-HR FIRE BARRIER SEPARATION2-HR FIRE-RATEDALTERATION CLASSIFICATIONS OF WORK, AS SPECIFIED IN THE 2020 EDITION OF THE BUILDING CODE OF NEW YORK STATE ARE AS FOLLOWS:ALTERATION -LEVEL 2:LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF DOORS AND WINDOWS, THE RECONFIGURATION OR THE EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL SYSTEM. LEVEL 2 ALTERATIONS SHALL ALSO COMPLY WITH THE REQUIREMENTS OF A LEVEL 1 ALTERATION.LEVEL 1 ALTERATIONS INCLUDE THE REMOVAL AND REPLACEMENT OR THE COVERING OF EXISTING MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES USING NEW MATERIALS, ELEMENTS, EQUIPMENT OR FIXTURES THAT SERVE THE SAME PURPOSE.CODE COMPLIANCE PLAN GENERAL NOTES1.23.CODE COMPLIANCE DRAWINGS ARE INTENDED TO ASSIST IN THE PERMIT PROCESS AND TO PROVIDE GENERAL INFORMATION TO THE CONTRACTORS WITH RESPECT TO LIFE-SAFETY PROVISIONS OF THE PROJECT. THESE DRAWINGS SHOULD NOT BE USED TO DETERMINE THE SCOPE OF OTHER WORK SPECIFICALLY INDICATED ELSEWHERE IN THE DOCUMENTS. THESE DRAWINGS SHALL BE USED FOR THE LOCATIONS OF FIRE-RESISTANT RATED WALL CONSTRUCTION.THE FOLLOWING BUILDING AND ACCESSIBILITY CODES AND STANDARDS ARE APPLICABLE TO THIS PROJECT:A. 2020 BUILDING CODE OF NEW YORK STATEB. 2020 FIRE CODE OF NEW YORK STATEC. 2020 PLUMBING CODE OF NEW YORK STATED. 2020 MECHANICAL CODE OF NEW YORK STATEE. 2020 FUEL GAS CODE OF NEW YORK STATEF. 2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATEG. NATIONAL ELECTRICAL CODE, NFPA 70, -2017 EDITION AS REFERENCED BY THE NYS CODES ABOVE.H. ICC A117.1, ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES -2009 EDITION AS REFERENCED BY THE NYS CODES ABOVE.I. U.S. DEPARTMENT OF JUSTICE, 2010 AMERICANS WITH DISABILITIES ACT (ADA) STANDARDS FOR ACCESSIBLE DESIGN.REFERENCE FCNYS CHAPTER 33 FOR FIRE SAFETY PROVISIONS DURING CONSTRUCTION, DEMOLITION.CODE COMPLIANCE PLAN LEGENDINDICATES FIRE-RESISTANT WALL CONSTRUCTION OF VARIOUS TYPES AND HOURLY RATINGS. SEE FIRE-RESISTANT CONSTRUCTION LEGEND.CPET = X'-X"COMMON PATH OF EGRESS TRAVEL(NOT TO EXCEED 100 FEET)EATD = X'-X"EGRESS ACCESS TRAVEL DISTANCE(NOT TO EXCEED 300 FEET)EXIT. MAINTAIN OPERATIONAL AT ALL TIMES DURING CONSTRUCTIONFIRE EXTINGUISHER CABINETFIRE EXTINGUISHER (BRACKET MOUNTED)ACCESSIBLE ELEMENT PER ANSI A117.1-2009XXLABXXXROOM NAMEFLOOR AREA (SF)EFECFEFIRE RESISTANCE RATING SCHEDULE FOR BUILDING ELEMENTSCONSTRUCTION CLASSIFICATION TYPE 1B.DESCRIPTIONTEST REFERENCECOMMENTSFIRE RESISTANCERATINGSTRUCTURAL FRAME INCLUDING COLUMNS, GIRDERS AND TRUSSES2 (EXISTING)-EXISTING ASSEMBLY, PROTECTED STRUCTURAL STEELINTERIOR AND EXTERIOR BEARING WALLS2--FLOOR CONSTRUCTION INCLUDING SUPPORTING BEAMS AND JOISTS2 (EXISTING)-EXISTING ASSEMBLY, POURED CONCRETE FLOOR SLABROOF CONSTRUCTION INCLUDING SUPPORTING BEAMS AND JOISTS1 (EXISTING)-EXISTING ASSEMBLYLEVEL 2 ALTERATION WORK AREAE2E2E2E2E2E2E2E2E2E2E2E2E2E2SEE2SEE2SEE2SEE2SEE2SEE2SEE2SEE2SEE2SEE2SEE2SEE2SECONTROL AREA (2 OF 2)CONTROL AREA (1 OF 2)CPET = 65'-4"EATD = 119'-2"G-0012EEEEXISTING CONTROL AREA SEPARATIONFEFECFE223 SFMAKER SPACE466A552 SFLAB466FIRE-RESISTANT CONSTRUCTION LEGENDDESCRIPTIONPLAN DESIGNATIONFIRE WALL2FW3FWFIRE BARRIER (HORIZONTAL EXIT, INCIDENTAL USE/HAZARD, OCCUPANCY SEPARATION)1FB2FBSHAFT ENCLOSURE (FIRE BARRIER AT ELEVATOR, STAIR OR MECHANICAL SHAFT)1SE2SEFIRE PARTITION (ELEV LOBBY & CORRIDOR WALL)1FPPRESUMED EXISTING FIRE-RATED ASSEMBLIESPREFIX E. SEE NOTE 1WHEN THE PREFIX "E" IS INDICATED ON THE CODE COMPLIANCE FLOOR PLAN, IT DENOTES EXISTING WALL CONSTRUCTION WITH A PRESUMED FIRE-RESISTANCE RATING OF THE TYPE INDICATED AS INDICATED ON RECORD DRAWINGS PROVIDED BY THE OWNER. THE ACTUAL CONDITIONS IN THE FIELD HAVE NOT BEEN VERIFIED TO CONFIRM COMPLIANCE. NEW PENETRATIONS SHALL BE CONSTRUCTED IN ACCORDANCE WITH UL LISTED THROUGH-PENETRATION FIRE STOP SYSTEMS FOR THE RATING INDICATED. NEW OPENINGS TO BE PROTECTED WITH OPENING PROTECTIVES FOR RATING INDICATED.PENETRATIONS THROUGH FIRE-RESISTANT CONSTRUCTION SHALL BE BUILT IN ACCORDANCE WITH U.L. LISTED AND FM APPROVED THROUGH-PENETRATION FIRESTOP SYSTEMS. SEE CODE COMPLIANCE PLAN FOR FIRE-RATED PARTITIONS LOCATIONS.2FW3FW1FB2FB1SE2SE1FPNOTES:1.EE2. These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions6/7/2021 1:29:18 PMBIM 360://20625.03 Cornell University Upson Hall Room 466/Upson Hall 466-ARCH-R20.rvt20625.03SDFCode Compliance Plan& NotesCRECREG-001100% ConstructionDocumentsCornell UniversityUpson Hall 466 Lab RenovationIthaca, NYJune 1, 2021NORTH1/4" = 1'-0"2Partial Fourth Floor Code Compliance Plan1/16" = 1'-0"1Fourth Floor Code Compliance Plan SCREW FASTENER TO STUDS ONLY2" x 20 GA. MIN DEEP LEG DEFLECTION TRACKCONT. LATERAL BRACE WITHIN 12" OF TOP TRACK 1 1/2 C.R. CHANNEL W/ 16 GA. CLIP ANGLE OR CONT. STRAPPING ON EA. SIDESTEEL STUDCUT STUDS 1" SHORT OF DECK OR BEAMGYPSUM BOARD -EXTEND TO TOP OF STUD ELEVATIONUPPER PART OF FLUTED DECKUNDERSIDE OF FLUTED DECK OR BEAMAT FIRE -RATED PARTITIONS:CONSTRUCT DETAIL IN ACCORDANCE WITH U.L. LISTED FIRE-RESISTANT JOINT SYSTEMS (HW-D). PROVIDE DEFLECTION TRACK ASSEMBLIES, FORMING/ FILL MATERIALS AND GYPSUM LINED SHEET METAL RESTRAINING ANGLES AS REQUIRED BY APPROVED JOINT SYSTEMAT NON-RATED PARTITIONS & SMOKE PARTITIONS: FOR PARTITIONS CONTAINING SOUND BATT INSULATION FILL FLUTES OF DECK WITH BATT INSULATION AND SEAL BOTH SIDES WITH SEALANT4"GYPSUM BOARD / METAL STUD SERIES PARTITIONSLEGENDINDICATES PARTITION TYPEINDICATES PARTITION HEIGHT ABOVEFINISHED FLOOR:"X" AFCPARTITION TO X" ABOVEFINISHED CEILINGUFCPARTITION TO UNDERSIDE OF FINISHED CEILINGX'-X"WHERE HEIGHT IS NOTED,CONSTRUCT WALL TO THATHEIGHT INCLUDING TOP OFWALL CAP7 1/4"6" CFMF AT 16" O.C.(1) LAYER 5/8" GYPSUM BOARD EACH SIDE.1 HOUR FIRE RESISTANT RATED WHEN INDICATED(WITH OR WITHOUT INSULATION) PER UL U419A6XX**A3INDICATES PARTITION TYPEINDICATES ADDITIONAL SOUND ATTENUATIONBLANKETS FOR ACOUSTICAL PURPOSES(REFER TO GENERAL PARTITION NOTES)APARTITIONS WITH SOUND ATTENUATION BLANKETS:GYPSUM BOARD TO BE "TYPE X" UNLESS OTHERWISE NOTEDALL PARTITIONS ARE TO BE TO THE UNDERSIDE OF DECK UNLESS OTHERWISE NOTEDDIMENSIONS SHOWN FOR EACH PARTITION DESCRIPTION INDICATE FACE-TO-FACETHICKNESS OF MATERIALS LISTED FOR THAT PARTITIONPROVIDE LISTED U.L. FIRE-RESISTANT JOINT ASSEMBLIES @ TOP OF ALL WALLS INDICATED TO BE FIRE-RESISTANT RATEDTHE TOP OF ALL PARTITIONS FRAMED AGAINST THE UNDERSIDE OF STRUCTURES SHALL HAVE PROVISIONS FOR DEFLECTION & RESTRAINT, REFER TO DETAIL 1/A-000REFER TO CODE COMPLIANCE PLANS FOR PARTITION FIRE RESISTANCE RATINGS.GYPSUM BOARD JOINT TREATMENT IN CONCEALED SPACES SHALL BE FIRE TAPED. UNLESS OTHERWISE INDICATED IN A SPECIFIC UL DESIGN, JOINTS SHALL BE FIRE TAPED, AND JOINTS AND FASTENER HEADS COVERED WITH (1) COAT OF JOINT COMPOUND. BASE LAYERS IN MULTI-LAYER SYSTEMS ARE NOT REQUIRED TO HAVE JOINTS OR FASTENER HEADS TAPED OR COVERED WITH JOINT COMPOUND. GENERAL PARTITION NOTES:A.B.C.D.E.F.G.H.GENERAL NOTES:ALL GENERAL NOTES PERTAIN TO ALL ARCHITECTURAL (A-SERIES) DRAWINGS IN THIS SETPROVIDE CONCEALED STEEL STUD BLOCKING OR 4" x 18 GA CONTINUOUS STEEL STRAPPINGATTACHED TO FACE OF STUDS BEHIND ALL WALL MOUNTED ITEMS SUCH AS: WALL CABINETS,SHELVING, COAT RODS, GRAB BARS, HANDRAILS, TOILET ACCESSORIES, ETC.SEE INTERIOR ELEVATIONS & FURNITURE PLANS FOR ADDITIONAL INFORMATION AND SCOPEDIMENSIONS LOCATING INTERIOR PARTITIONS ARE TO THE FACE OF WALL (EXCLUDING FINISHMATERIALS SUCH AS -BUT NOT LIMITED TO: CERAMIC TILE, AND WOOD PANELING) UNLESS NOTED OTHERWISE. SEE PARTITION SCHEDULE FOR WALL THICKNESSALL EXISTING DIMENSIONS ARE APPROXIMATE AND FOR CONTRACTORS VERIFICATIONS. IFDISCREPANCIES ARISE, NOTIFY THE ARCHITECT (AND/OR CONSTRUCTION MANAGER) PRIORTO PROCEEDING WITH THE WORK THAT MAY BE EFFECTED BY THE DIMENSION CHANGEEVERY ATTEMPT HAS BEEN MADE TO INDICATE PERTINENT EXISTING UTILITIES AND CONDITIONSAS ACCURATELY AS POSSIBLE FROM EXISTING SURVEYS, DRAWINGS AND OTHER DATA. PRIORTO THE BID OPENING, CONTRACTORS SHALL WALK THE JOB SITE AND SATISFY THEMSELVESTO EXISTING CONDITIONS. THE ARCHITECT SHALL BE CONSULTED WHEN ANY QUESTIONARISES RELATIVE TO MATERIALS NOT SPECIFICALLY SHOWN OR SPECIFIEDALL EXISTING WORK (CEILINGS, FLOORS, WALLS, PARTITIONS, FINISHES, ETC.) DISTURBED BY NEW CONSTRUCTION, INCLUDING MECHANICAL, PLUMBING, AND ELECTRICAL, SHALL BE PATCHED AND REPAIRED TO RESTORE SURFACES TO THE ORIGINAL CONDITION AFTER INSTALLATION OF OTHER WORKPENETRATIONS THROUGH FIRE-RESISTANT CONSTRUCTION SHALL BE BUILT IN ACCORDANCEWITH U.L. LISTED AND FM APPROVED THROUGH-PENETRATION FIRESTOP SYSTEMS. SEE CODE COMPLIANCE PLAN FOR PARTITION LOCATIONS. PENETRATIONS THROUGH NON FIRE-RESISTANT RATED HORIZONTAL ASSEMBLIES, NOT PROTECTED BY A SHAFT ENCLOSURE, SHALL HAVE ITSANNULAR SPACE FILLED WITH NON-COMBUSTIBLE MATERIAL TO PREVENT THE PASSAGE OFFLAME, SMOKE FUMES, AND HOT GASES. NON-COMBUSTIBLE PENETRATING ITEMS SHALL NOTPENETRATE MORE THAN 3 FLOOR ASSEMBLIES. COMBUSTIBLE PENETRATING ITEMS SHALL NOTPENETRATE MORE THAN 1 FLOOR ASSEMBLY1.2.3.4.5.6.7.PROVIDE SOUND ATTENUATION BLANKETS IN ALL CAVITY SPACES IN WALL FULL HEIGHTTHICKNESS OF BLANKETS IN STUD WALLS SHALL BE EQUAL TO THICKNESS OF CAVITY TO NEAREST 1/2", UNLESS INDICATED OTHERWISEPARTITIONS TO BE SEALED @ THE PERIMETER, BEHIND CONTROL JOINTS, AROUND OPENINGS AND AT ALL PENETRATIONS WITH EACH LAYER OF BOARD TO RECEIVE A BEAD OF NON-HARDENING SEALANTSEE WALL TYPE DESCRIPTIONS FOR CONDITIONS REQUIRING MINERAL FIBER SAFING INSULATION BATTS1.2.3.4.REFER TO CODE COMPLIANCE PLAN(S) FOR PARTITIONS REQUIRED TO BE FIRE-RESISTANT-RATED CONSTRUCTION.These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions6/7/2021 1:29:05 PMBIM 360://20625.03 Cornell University Upson Hall Room 466/Upson Hall 466-ARCH-R20.rvt20625.03SDFGeneral Notes &LegendsCREAD/CREA-000100% ConstructionDocumentsCornell UniversityUpson Hall 466 Lab RenovationIthaca, NYJune 1, 2021AB Anchor boltA/C Air condition(ing) (ed)ACC AccessibleACCU Air cooled condensing unitACI American Concrete InstituteACT Acoustical ceiling tileACM Asbestos containing materialACOUS PNL Acoustical panelACS PNL Access panelADDL AdditionalADJ Adjustable, adjacentADH AdhesiveAFF Above finished floorAGGR AggregateAHU Air handling unitAISC American Institute of Steel ConstructionAISI American Iron and Steel InstituteALT AlternateALUM AluminumANOD AnodizedAPPROX ApproximateARCH Architect(ural)ARD Auxillary roof drainASD Allowable stress designASTM American Society for Testing and MaterialsAWP Acoustical wall panelAWS American Welding SocietyBAT BattenB/B Back to backB BD Base boardBCNYS Building Code of New York StateBITUM BituminousBD BoardBLDG BuildingBLKG BlockingBM Beam, BenchmarkBOT BottomBR BedroomBRG BearingBRZ BronzeBSMT BasementBTWN BetweenBUR Built up roofingBW Both waysCCTV Closed circuit televisionCAB CabinetCB Catch basin, Corner beadCH BD ChalkboardCEM CementCF Contractor furnishedCFMF Cold-formed metal framingCF/CI Contractor furnished/ Contractor installedCF/OI Contractor furnished/ Owner installedCG Corner guardCH Coat hookCI Cast ironCIP Cast in place, Cast iron pipeCJ Control jointCL CenterlineCLG CeilingCLO ClosetCLR Clear, ColorCMT Ceramic mosaic tileCMU Concrete masonry unitCNTR CounterCO Cleanout, Cased opening, CompanyCOL ColumnCONC ConcreteCONF ConferenceCONN Connect(ion)CONSTR ConstructionCONT Continue(ous)CONTR Contract(or)COORD CoordinateCPT CarpetC.R. Cold-RolledCSJ Construction jointCSK Counter sunkCT Ceramic tile, Count, Current transformerCTR CenterCW Cold water piping, Casement windowCU CubicCUH Cabinet unit heaterCU YD Cubic yardD Deep, DepthD Penny (nail)db Bar diameterDBL DoubleDEFS Direct-applied exterior finish systemDEG DegreeDEMO DemolitionDEPT DepartmentDET DetailDF Drinking fountainDIA OR ø DiameterDIAG Diagonal, DiagramDIM DimensionDIFF DiffuserDIR DirectionDISP DispenserDIV DivisionDMPF Damp proofingDL Dead loadDN DownDO DittoDR Door, DriveDS DownspoutDW DishwasherDWVDrainage waste & ventDWGDrawingDWLDowelEEastEAEachEBCNYSExisting Building Code of New York StateECElectrical contractorEFEach faceEIFSExterior insulation and finish systemEJExpansion jointELASElastomericELElevationELECElectric(al)ELEVElevatorEMEntry mat, Expanded metalEMEREmergencyENCLEnclosureENGREngineerEOSEdge of slabEPElectric panelEQEqualEQUIPEquipmentESEmergency showerETCEt ceteraETRExisting to remainEWEach wayEWCElectric water coolerEXISTExistingEXCExcavation, ExcavateEXPExpand, ExpansionEXTExterior, External, ExtinguisherF/FFace to faceFAAPFire alarm annunciator panelFACPFire alarm control panelFDFloor drainFDTNFoundationFEFire extinguisherFECFire extinguisher cabinetFHCFire hose cabinetFINFinish(ed)FIXTFixtureFLASHFlashingFLEXFlexibleFLOURFluorescentFLGFlooring, flangeFOFinished openingFPFire protection, FireproofFRTWFire retardant treated woodFTFoot, FeetFTGFootingFTRFinned tube radiationFURNFurnace, Furniture, FurnishFUTFutureFWCFabric wall coveringGAGageGALGallonGALVGalvanizedGBGrab barGCGeneral contract(or)GFRCGlass fiber reinforced concreteGFRGGlass fiber reinforced gypsumGLGlass, Ground levelGL BLKGlass blockGLU LAMGlued laminated beamGRGrade, GrossGWTGlazed wall tileGYPGypsumGYP BDGypsum boardGYP PLASGypsum plasterHBHose bibbHCHollow core, Hose cabinetHCPHandicappedHDWHardwareHDWDHardwoodHMHollow metalHOHold openHORIZHorizontalHPHigh point, HorsepowerHRHourHSSHollow structural sectionHTHeightHTGHeatingHTRHeaterHVACHeating, ventilating and air conditioningHWHot waterHYDHydrantIDInside diameterINInchesINCLIncludedINCANDIncandescentINFOInformationINSULInsulationINTERMIntermediateINTInteriorJANJanitorJSTJoistJTJointKIP1000 PoundsKITKitchenKOKnockoutKPLKick plateLLiter, AngleLAMLaminate(d)LAULaundryLAVLavatoryLBPoundLBLLabelLDLoadLFLinear feet (foot)LHLeft hand, Latent heatLINLinearLKRLockerLLLive loadLLHLong leg horizontalLLVLong leg verticalLOCLocationLRFDLoad & resistance factor designLTLightLTGLightingLWCLight-weight concreteMACHMachineMAINTMaintenanceMASMasonryMATLMaterialMAXMaximumMCMechanical contractorMCBMetal corner beadMDOMedium density overlayMDFMedium density fiberboardMECHMechanicalMEPMechanical, electrical, plumbing and fire protectionMEZZMezzanineMFRManufacturerMHManholeMMMillimeterMIFRCMastic/intumescent fire-resistive coatingMINMinimumMISCMiscellaneousMLWKMillworkMOMasonry openingMRK BDMarker boardMTDMountedMTLMetalMULLMullionNNorthNATNaturalNCOMBLNoncombustibleNICNot in contractNO OR #NumberNOMNominalNORMNormalNRCNoise reduction coefficientNTSNot to scaleNWCNormal weight concreteO/OOut to outOAOverall, Outside airOCOn centerODOutside diameterOF/CIOwner furnished, Contactor installedOF/OIOwner furnished, Owner installedOFDOverflow drainOFFOfficeOHOpposite handOH DROverhead (coiling) doorOPNGOpeningOPPOppositeOPTOptional, OptimumOZOuncePAPublic addressPBDParticleboardPCPlumbing contractor, Portland cementPCCPrecast concretePCTPorcelain ceramic tilePEDPedestalPENDPendantPERPeriodPERFPerforatedPGBDPeg boardPLPlate, Property linePLFPonds per linear footPLAMPlastic laminatePLASPlasterPLBPlumbingPLYWDPlywoodPNLPanelPOLPolishedPORCPorcelainPOSPositive, PositionPPTPressure-preservative treatedPRPairPREFABPrefabricatePREFINPrefinishPREPPreparationPROJProjectPROJ SCRN Projection screenPSFPounds per square footPSIPounds per square inchPTPaint, Post tensionPTNPartitionPVCPolyvinyl chloride (plastic)PVGPavingQTQuarry tileQTRQuarterQTYQuantityRRiser, Radius, Thermal resistanceRBRubber base, Resilient baseRCPReinforced concrete pipe, Reflected ceiling planRDRoof drain, RoadRECRecessedREFRefrigeratorREFLReflectREGRegister, RegulationREINFReinforcedREQDRequiredRESILResilientREVRevisionRFResilient flooringRFGRoofingRHRight hand, Roof hatchRMRoomRORough openingROWRight of wayRTURoof top unitRVRoof ventRWBRubber wall baseSSouthSABSound attenuation battsSANSanitarySCSolid core, Shading coefficientSCHEDScheduleSEALSealer on floor (finish)SECTSectionSFSquare foot, Safety factorSFRMSprayed fire-resistiveMaterialSGTStructural glazed tileSHTSheetSHRShowerSIMSimilarSOGSlab on gradeSPStandpipe, Sump pitSPASpacesSPKRSpeakerSPECSpecificationSQSquareSRDSecondary roof drainSSService sinkSSMSolid surface materialSSPStainless steel pipeSSTStainless steelSTStainSTAStationSTCSound transmission classSTDStandardSTIFFStiffenerSTLSteelSTORStorageSTRStraight, StringersSTRUCTStructuralSUSPSuspendedSVSheet vinylSYSquare yardTTreadT/Top ofT&BTop and bottomT>ongue and grooveTELTelephoneTHRESThresholdTEMPTemporaryTERTerrazzoTHKThick(ness)TK BDTack boardTMPDTemperedTOCTop of concreteTOMTop of masonryTOPOTopography, TopographicTOSTop of steelTOWTop of wallTPDToilet paper dispenserTSTATThermostatTVTelevisionTYPTypicalUHeat transfer coefficientUCUndercutUCLUnder cabinet lightingUGNDUndergroundUHUnit heaterULUnderwriter's laboratoriesUNEXUnexcavatedUNFINUnfinishedUONUnless otherwise notedUTILUtilityUVUnit ventilatorVARNVarnish(ed)VBVinyl baseVCTVinyl composition tileVENTVentilationVERTVerticalVESTVestibuleVIFVerify in fieldVINVinylVOLVolumeVRVapor retarderVTVinyl tileV SHTVinyl sheetVWCVinyl wall coveringWWestW/WithWCWater closet, Wall coveringW/OWithoutWDWoodWDWWindowWFWide flangeWD GDWood guardWHWater heaterWIWrought ironWMWire meshWPWaterproofing, Working pointWRWater repellent, weather resistantW RECPTWaste receptacleWSCTWainscotWTWeight, Watertight, Water tableWWFWelded wire fabricXByYDYardC12AC12A-XXX1432XSCALE: X"=1'-0"Title112BA18'-0" AFF1Batt insulationRigid insulationWood blocking (intermittent) StoneGravel or crushed stoneWood framing (continuous)Finish woodSteel -large scaleSteel -small scalePlywoodConcreteConcrete masonry unitBrick(Other metals as noted)View titleBuilding / wall section cutDetail -blow upExterior elevationInterior elevations1011Partition typeRoom numberDoor numbersWindow typeRevisionORORUndisturbed earth001100A001Structural gridViewing directionDetail no.Drawing no.Detail no.Drawing no.Drawing no.Elevation no.Plan key noteDemolition key noteCeiling type and heightDrawing symbols(Other metals as noted)A-XXXXA-XXXXGypsum, sand, mortarA-XXXXDrawing no.Elevation no.Detail no.Detail section cutDetail no.DRAWING NO.A-XXXXViewing directionAccessibilityAccessible unitV/HAUVisual / hearing accommodation unitMaterial symbolsArchitectural / Structural abbreviations3" = 1'-0"1TYP Deflection Head Detail FEFEFE86.156GFBDCAA-4205A-42013426717' - 11"(+/- 4' - 6" )(+/- 35' - 2" )(+/- 32' - 4" )AA6AA61228' - 3"2' - 3"EFGHLAB466MAKER SPACE466A466A3654ALIGN(+/- 13' - 10" )278' - 7""DRYING AREA"JWORKBENCH, OF/OIWORKBENCHES, OF/OI"COLLABORATION/BUILD AREA"1A-6011A-601SIM8' - 3"3' - 9"FUTURE LOCATION OF LOW EXHAUST DUCT DROPFUTURE LOCATION OF LOW EXHAUST DUCT DROP88EQEQLKKNMOOOI10ETR11' -1 1/4"ETR9' -5 3/8"ETR11' -1 1/4"ETR9' -5 3/8"ETR11' -1 1/4"ETR9' -5 3/8"ETR LIGHT FIXTURELIGHT FIXTURE MATCHED TO EXISTING LIGHT FIXTURES, REFER TO ELECTRICAL DRAWINGSETR GYP BD CEILING AND SOFFITS, TYP.ETR11' -1 1/4"ETR11' -1 1/4"ETR11' -1 1/4"GENERAL NOTES:1. PAINT ALL NEW AND EXISTING EXPOSED DUCTWORK PER ROOM FINISH SCHEDULE.1A-601ETR9' -5 3/8"19' -5 3/8"MODIFIED SOFFITEQEQEQEQEQ1' - 1"14' - 0"VIF+/- 2' - 0"EQ8' - 0"VIF+/- 2' - 0"A-102299CDCDCD86.156GF122231LAB4664NOTE:EXISTING FLOORING AND BASE TO REMAIN, UON. PROVIDE TEMPORARY PROTECTION DURING DEMOLITION AND CONSTRUCTION TO PROTECT ETR FINISHES & SURFACESEXISTING CASEWORK AND PLUMBING TO REMAIN. PROVIDE TEMPORARY PROTECTION DURING DEMOLITION AND CONSTRUCTION.5VIF+/- 3' - 0"VIF+/- 3' - 0"VIF+/- 3' - 0"EXISTING TO REMAIN WALL SHELVING UNITS6614' - 0"8' - 0"VIF+/- 25' - 0"773A-601EXTENT OF PARTIAL SOFFIT REMOVAL ABOVE, REFER TO DETAIL+/- 18' - 6"RCP LEGENDLINEAR LIGHT FIXTURE, SUSPENDEDEXHAUST AIR GRILLE, REFER TO MECHANICAL DRAWINGS ETREXISTING TO REMAIN GYP BDCEILING TYPESCDCORD DROP, REFER TO ELECTRICAL DRAWINGS EVERY ATTEMPT HAS BEEN MADE TO DOCUMENT PERTINENT EXISTING CONDITIONS FROM EXISTING SURVEYS, DRAWINGS AND LIMITED FIELD INSPECTION. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS SHALL WALK THE SITE AND SATISFY THEMSELVES TO EXISTING VISUAL CONDITIONS. THE ARCHITECT SHALL BE CONSULTED WHEN ANY QUESTION ARISES RELATIVE TO MATERIALS AND CONDITIONS NOT SPECIFICALLY SHOWN OR SPECIFIED.ALL EXISTING WORK (CEILING, FLOORS, WALLS, FINISHES, ETC.) DISTURBED BY NEW CONSTRUCTION SHALL BE PATCHED AND REFINISHED. PATCHING AND FINISH WORK IS THE REPAIR WORK REQUIRED TO RESTORE SURFACES TO THE ORIGINAL CONDITION AND/ OR MATCHING THE ADJACENT SURFACES. MISCELLANEOUS FINISH REQUIREMENTS TO WALL, FLOOR AND CEILING IN AREAS AFFECTED BY DEMOLITION HAVE NOT BEEN TOTALLY INCORPORATED INTO THE ROOM FINISH SCHEDULE. REFER TO THE DEMOLITION , FLOOR AND REFLECTED CEILING PLANS FOR ADDITIONAL CUTTING , PATCHING AND REFINISHING WORK SCOPE.THE EXISTING FIRE-RESISTANT CONSTRUCTION MUST BE MAINTAINED OR MADE TO COMPLY WITH THE REQUIREMENTS AS ESTABLISHED BY THIS CONTRACT. SEE THE CODE COMPLIANCE PLANS FOR THE FIRE RESISTANT RATINGS OF EXISTING AND NEW CONSTRUCTION.CARE SHALL BE TAKEN TO LIMIT IMPACT OF CONSTRUCTION ON THE SURROUNDING OCCUPANTS AND OPERATIONS DURING THE PROJECT. SAFE LEGAL PASSAGES SHALL BE PROVIDED FOR ALL BUILDING OCCUPANTS DURING ALL THE PHASES OF THIS PROJECT.WHEN EXISTING CONSTRUCTION WHICH IS TO REMAIN IS DAMAGED DURING THE COURSE OF CONSTRUCTION AS A RESULT OF CONTRACTOR'S WORK, IT SHALL BE REPAIRED AND/OR REPLACED WITH SIMILAR OR LIKE MATERIALS, SUBJECT TO ARCHITECT'S APPROVAL AND WITHOUT COMPENSATION.'REMOVE' IS DEFINED AS DETACH FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSE OF OFF-SITE UNLESS INDICATED TO BE SALVAGED OR REINSTALLED1.2.3.4.5.6.GENERAL DEMOLITION NOTES:GENERAL NOTES:ALL FLOORS, WALLS, CEILINGS, AND OTHER SURFACES THAT ARE TO REMAIN ARE TO BE PROTECTED, PATCHED, REPAIRED, AND REFINISHED PRIOR TO FINISH INSTALLATION. ALL SURFACES ARE TO BE RESTORED TO THEIR ORIGINAL CONDITION AND/OR MATCH THE ADJACENT SURFACES.FIRESTOP ALL FLOOR PENETRATIONS (USED/UNUSED/ABANDONED) WITH 2 HR UL LISTED AND FM APPROVED PENETRATION FIRESTOPPING.PAINT ENTIRE CEILING, BEAMS, AND SOFFITS WITHIN LAB 466 PT-2. SEE RFS.THE CONTRACTOR SHALL ADVISE THE ARCHITECT OF EQUIPMENT WITH OPERATING WEIGHTS EXCEEDING 40 PSF OR A CONCENTRATED LOAD EXCEEDING 500 LBS." " INDICATES LAB EQUIPMENT AND FURNISHINGS, REFER TO A-102 FOR 'LAB EQUIPMENT AND FURNISHINGS SCHEDULE'1.2.3.4.5.#86.156GFAA6LAB466MAKER SPACE466A"DRYING AREA"AA6RPQSTUYXVWRPQRPQRPQRRSTTTWWXThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions6/7/2021 1:29:07 PMBIM 360://20625.03 Cornell University Upson Hall Room 466/Upson Hall 466-ARCH-R20.rvt20625.03SDFPartial Fourth FloorPlansCREAD/CREA-101100% ConstructionDocumentsCornell UniversityUpson Hall 466 Lab RenovationIthaca, NYJune 1, 20211/4" = 1'-0"2Partial Fourth Floor Plan1/4" = 1'-0"3Partial Fourth Floor Reflected Ceiling PlanNORTHPLAN KEYNOTESNO.DESCRIPTION1REINSTALL SALVAGED MARKERBOARD2REINSTALL SALVAGED WALL MOUNTED SHELVING AND STANDARDS. PATCH AND REPAIR GYPSUM BOARDWHERE BLOCKING INSTALLATION IS REQUIRED.3PROVIDE 24" H x 36" W MARKERBOARD WITH MARKER TRAY, BOD: CLARIDGE FPM14-0203-Z, COLOR:WHITE4REINSTALL FIRE EXTINGUISHER AND WALL BRACKET.5PROVIDE 2"H COLLAPSIBLE RUBBER WATER DAM INSTALLED AT PERIMETER OF "DRYING AREA" (BOD:DUZZY COLLAPSIBLE WATER DAM D1). USE MAXIMUM LENGTH PRODUCT AVAILABLE TO MINIMIZE JOINTS.ALL JOINTS AND TERMINATIONS TO RECEIVE COLOR MATCHING SILICONE SEAL.6PROVIDE FRP WALL FINISH. PANEL TO MEET CLASS A FIRE RATING AND FM APPROVAL. BOD: CRANE FIRE-XGLASBORD. ALL PREPARATION OF SUBSTRATE SURFACES TO BE COMPLETED PER MANUFACTURER'SINSTALLATION GUIDELINES. SEE INTERIOR ELEVATIONS7PROVIDE WALL MOUNTED SST HOOKS. SEE INTERIOR ELEVATIONS.8PROVIDE (1) LAYER OF GYPSUM BOARD AT OPENING IN PARTITION. PREP AND FINISH TO RECEIVESCHEDULED FINISHES.9REINSTALL SALVAGED AND MODIFIED OVERHEAD UNISTRUT CARRIER, COORDINATE FINAL LOCATION WITHUTILIITES. PAINT TO MATCH EXISTING COLOR. CUT, PATCH AND REPAIR GYPSUM BOARD CEILING ASREQUIRED TO ANCHOR OVERHEAD CARRIER TO EXISTING CONCRETE AND METAL DECK ABOVE. PREPGYPSUM BOARD TO RECEIVE SCHEDULED FINISH.10SAFTEY GLASSES STORAGE (BOD: FISHERBRAND ACRYLIC SAFETY GLASSES HOLDER, 12-UNIT, 03-391-578).SEE INTERIOR ELEVATION.1/4" = 1'-0"1Partial Fourth Floor Demolition PlanINDICATES PLAN KEYNOTE#DEMOLITION KEYNOTESNO.DESCRIPTION1REMOVE AND SALVAGE WALL MOUNTED SHELVING UNITS ON WALL STANDARDS & ASSOCIATEDCOMPONENTS.TURN OVER TO OWNER. PATCH, REPAIR AND PREP GYP BD TO MATCH ADJACENTSURFACES AND TO RECEIVE SCHEDULED FINISH.2REMOVE AND SALVAGE WALL MOUNTED SHELVING UNITS ON WALL STANDARDS FOR REINSTALLATION.PATCH, REPAIR AND PREP EXISTING GYP BD TO MATCH ADJACENT SURFACES AND TO RECEIVESCHEDULED FINISH.3REMOVE AND SALVAGE FIRE EXTINGUISHER AND WALL BRACKET FOR REINSTALLATION. PREP, PATCH ANDREPAIR GYP BD PARTITION TO MATCH ADJACENT SURFACE AND TO RECEIVE SCHEDULE FINISH.4REMOVE AND SALVAGE MARKER BOARD FOR REINSTALLATION. PATCH, REPAIR AND PREP EXISTING GYPBD TO MATCH ADJACENT SURFACES AND TO RECEIVE SCHEDULED FINISH.5REMOVE AND SALVAGE PORTION OF OVERHEAD CARRIER (UNISTRUT). TURN OVER TO OWNER. PATCH,REPAIR AND PREP GYP BD CEILING TO MATCH ADJACENT SURFACES.6REMOVE, SALVAGE AND MODIFY OVERHEAD UNISTRUT CARRIER TO LENGTHS INDICATED ON THE PLAN.PATCH, REPAIR AND PREP GYP BD CEILING TO MATCH ADJACENT SURFACES.7REMOVE (1) LAYER OF GYPSUM BOARD TO ACCOMMODATE PLUMBING WORK. REFER TO PLUMBING PLANS.INDICATES DEMOLITION KEYNOTE#1/4" = 1'-0"4Partial Furniture Fourth Floor Plan -For Reference Only (NIC) REMOVE LAYER OF GYPSUM BOARD TO ACCOMMODATE PLUMBING WORK. PROVIDE (1) LAYER OF GYPSUM BOARD UPON COMPLETION OF PLUMBING WORK. PATCH, REPAIR AND FINISH TO MATCH EXISTING WALL SURFACE. REFER TO PLUMBING DRAWINGS.REMOVE LAYER OF GYPSUM BOARD TO ACCOMMODATE PLUMBING WORK. PROVIDE (1) LAYER OF GYPSUM BOARD UPON COMPLETION OF PLUMBING WORK. PATCH, REPAIR AND FINISH TO MATCH EXISTING WALL SURFACE. REFER TO PLUMBING DRAWINGS.LAB366NOTE: LAB DOES NOT HAVE A DROPPED CEILING, CONCRETE DECK IS EXPOSED ABOVEETR8' -0"ETR8' -0"ETR8' -2"ETR 24" X 60" SUSPENDED ACOUSTICAL TILE CEILINGETR GYP BD SOFFITETR 24" X 24" SUSPENDED ACOUSTICAL TILE CEILINGNOTE: REMOVE AND REINSTALL ACOUSTICAL CEILING TILES AS REQUIRED TO ACCOMMODATE MECHANICAL, ELECTRICAL AND PLUMBING WORK. ANY DAMAGED TILES SHALL BE BROUGHT TO THE OWNER'S ATTENTION PRIOR TO REMOVALS AND/OR DOCUMENTED THROUGH PRE-CONSTRUCTION PHOTOGRAPHS. IF CONTRACTOR DOES NOT DOCUMENT OR NOTIFY THE OWNER OF THE DAMAGE PRIOR TO REMOVALS, DAMAGED COMPONENTS SHALL BE REPLACED WITH NEW MATERIAL AT CONTRACTOR'S EXPENSE.ETR GYP BD CEILING AND SOFFITSETR9' -4"ETR11' -2"ETR11' -2"ETR11' -2"ETR9' -4"ETR9' -4"ETR8' -0"ETR8' -0"LAB466MAKER SPACE466A468465467PATCH AND REPAIR GYPSUM BOARD AT PENETRATIONS. PAINT TO MATCH EXISTING.REMOVE AND REINSTALL ACT AS REQUIRED TO ACCOMMODATE MEP WORK, REFER TO MEP DRAWINGS.REMOVE AND REINSTALL ACT AS REQUIRED TO ACCOMMODATE MEP WORK, REFER TO MEP DRAWINGS.REMOVE AND REINSTALL ACT AS REQUIRED TO ACCOMMODATE MEP WORK, REFER TO MEP DRAWINGS.ETR 24" X 24" SUSPENDED ACOUSTICAL TILE CEILINGA-1013These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions6/7/2021 1:29:07 PMBIM 360://20625.03 Cornell University Upson Hall Room 466/Upson Hall 466-ARCH-R20.rvt20625.03SDFPartial Plans & LabEquipment ScheduleCRECREA-102100% ConstructionDocumentsCornell UniversityUpson Hall 466 Lab RenovationIthaca, NYJune 1, 20211/4" = 1'-0"1Partial Third Floor Plan1/4" = 1'-0"2Partial Fourth Floor Reflected Ceiling PlanNORTHLAB EQUIPMENT & FURNISHINGS SCHEDULELETTERQTYEQUIPMENT NAMEMANUFACTURERMODEL NO.LOCATIONDIMENSIONSELECTRICALHOUSE LABORATORY PLUMBING SYSTEMSCYLINDERGASESOPERATING ENVIRONMENTHEATGENERATION(BTUH)EXHAUST(CFM)OWNERFURNISHEDOWNERINSTALLEDCONTRACTORFURNISHEDCONTRACTORINSTALLEDCOMMENTSHEIGHT(IN)WIDTH(IN)DEPTH(IN)WEIGHT(LBS)NORMALVOLTAGE(VAC)PHASEHzPOWER DRAWEMERGENCYPOWERPLUG TYPE(SEE NOTE 1)DCWDHWPCWLABDRAINLABVENTRODIGASPROPANEVACCA 85PSICALPTEMP (*F)HUMIDITY %VIBRATIONSENSITIVEAMPSHPWATTSA(1)MILL DRILLLITTLEMACHINESHOPHITORQUEMINI MILLBENCH36.323.219.71241201608.67--------------XXB(1)3D PRINTERMARKFORGEDMARK TWO(GEN 2)BENCH142313351201602150--------------XXC(1)3D PRINTERPRUSAI3 MK3S+BENCH18.92120.524.360120--------------XXD(1)DRILL PRESSJET716250FLOOR63.251727172120160.75--------------XXE(1)BANDSAWJET414504CFLOOR73.525.522.382802303603.61---------------XXXCONTRACTOR TO CONNECT MOTOR TO POWERSOURCE. SEE ELECTRICAL DRAWINGS.F(1)LASER CUTTEREPILOGTBDFILTRATIONBOX39.836.532180120160--------------350-400XXXCONTRACTOR TO INTERLOCK WITH FILTRATIONBASE AND COMMISSION. LASER CUTTER MODELIS TBD BETWEEN EPILOG ZING 24 60-WATT ANDEPILOG FUSION EDGE 24 80-WATT.G(1)WATERJETOMAXPROTOMAXFLOOR56.541.539.5750230-240160305-L14-30X---------50-90<95-XXH(1)DC POWER SUPPLYKEYSIGHT TECHNOLOGIESN8926ABENCH5.317.730.159208360-----------32-11380-XXI(1)THUMB LEVER AIR GUNCA HOSE-------------------------XXREFER TO PLUMBING DRAWINGSJ(1)FILTRATION BOXBOFAAD BASE 2ORACLEFLOOR21.6541.7431.89207120160121100--------------XXXCONTRACTOR TO INTERLOCK WITH LASERCUTTER AND COMMISSION.K(2)METAL TOOL STORAGE PEGBOARDWALLMOUNTED4242------------------------XXCOLOR: WHITEL(1)TALL STORAGE CABINETMOTT6535760FLOOR844822-----------------------XXWOOD VENEER DOORS AND PAINTED STEELCABINET BODY TO MATCH EXISTING CASEWORKM(1)TALL STORAGE CABINETMOTTSIM TO6530030-80FLOOR844822-----------------------XXWOOD VENEER DOORS AND PAINTED STEELCABINET BODY TO MATCH EXISTING CASEWORK.GLASS FRAMED DOORS.N(1)COAT RACKWALLMOUNTED5.5345/4-----------------------XXWOOD SPECIES AND FINISH MATCHED TOEXISTING CASEWORKO(3)UNDERSHELF LIGHT FIXTUREMOTTTLW0024SHELF-24-----------------XXP(4)MOBILE BASE CABINET, NICFLOOR-----------------------XXQ(4)WORK TABLE, NICFLOORADJ.6030-----------------------XXADJUSTABLE HEIGHTR(6)LAB CHAIR, NICFLOOR-----------------------XXS(2)MOBILE, POWERED LAPTOPWORKSTATION, NICFLOORADJ.6030----------------XXT(4)LOUNGE CHAIR, NICFLOOR-----------------------XXU(1)COFFEE TABLE, NICFLOOR-----------------------XXV(1)MAPLE WORKSURFACE, NICBENCH-30-----------------------XXW(3)STEEL CABINET, NICFLOOR303027.75-----------------------XXX(2)LAB STOOL, NICFLOOR-----------------------XXY(1)MOBILE WORKTABLE, NICFLOOR364824-----------------------XXSTORAGE SHELF BELOWINDICATES EQUIPMENT KEYNOTE#LAB EQUIPMENT SCHEDULE NOTES:1. ELECTRICAL SUBCONTRACTOR TO CONFIRM PLUG TYPE WITH OWNER. REMOVE LAYER OF GYPSUM BOARD TO ACCOMMODATE PLUMBING WORK. PROVIDE (1) LAYER OF GYPSUM BOARD UPON COMPLETION OF PLUMBING WORK. PATCH, REPAIR AND FINISH TO MATCH EXISTING WALL SURFACE. REFER TO PLUMBING DRAWINGS.REMOVE LAYER OF GYPSUM BOARD TO ACCOMMODATE PLUMBING WORK. PROVIDE (1) LAYER OF GYPSUM BOARD UPON COMPLETION OF PLUMBING WORK. PATCH, REPAIR AND FINISH TO MATCH EXISTING WALL SURFACE. REFER TO PLUMBING DRAWINGS.LAB366NOTE: LAB DOES NOT HAVE A DROPPED CEILING, CONCRETE DECK IS EXPOSED ABOVEETR8' -0"ETR8' -0"ETR8' -2"ETR 24" X 60" SUSPENDED ACOUSTICAL TILE CEILINGETR GYP BD SOFFITETR 24" X 24" SUSPENDED ACOUSTICAL TILE CEILINGNOTE: REMOVE AND REINSTALL ACOUSTICAL CEILING TILES AS REQUIRED TO ACCOMMODATE MECHANICAL, ELECTRICAL AND PLUMBING WORK. ANY DAMAGED TILES SHALL BE BROUGHT TO THE OWNER'S ATTENTION PRIOR TO REMOVALS AND/OR DOCUMENTED THROUGH PRE-CONSTRUCTION PHOTOGRAPHS. IF CONTRACTOR DOES NOT DOCUMENT OR NOTIFY THE OWNER OF THE DAMAGE PRIOR TO REMOVALS, DAMAGED COMPONENTS SHALL BE REPLACED WITH NEW MATERIAL AT CONTRACTOR'S EXPENSE.ETR GYP BD CEILING AND SOFFITSETR9' -4"ETR11' -2"ETR11' -2"ETR11' -2"ETR9' -4"ETR9' -4"ETR8' -0"ETR8' -0"LAB466MAKER SPACE466A468465467REMOVE AND REINSTALL ACT AS REQUIRED TO ACCOMMODATE MEP WORK, REFER TO MEP DRAWINGS.REMOVE AND REINSTALL ACT AS REQUIRED TO ACCOMMODATE MEP WORK, REFER TO MEP DRAWINGS.ETR 24" X 24" SUSPENDED ACOUSTICAL TILE CEILINGA-1013These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions6/29/2021 6:04:08 PMBIM 360://20625.03 Cornell University Upson Hall Room 466/Upson Hall 466-ARCH-R20.rvt20625.03SDFPartial Plans & LabEquipment ScheduleCRECREA-102R100% ConstructionDocumentsCornell UniversityUpson Hall 466 Lab RenovationIthaca, NYJune 1, 2021107/01/21ADDENDUM #11/4" = 1'-0"1Partial Third Floor Plan1/4" = 1'-0"2Partial Fourth Floor Reflected Ceiling PlanNORTHLAB EQUIPMENT & FURNISHINGS SCHEDULELETTERQTYEQUIPMENT NAMEMANUFACTURERMODEL NO.LOCATIONDIMENSIONSELECTRICALHOUSE LABORATORY PLUMBING SYSTEMSCYLINDERGASESOPERATING ENVIRONMENTHEATGENERATION(BTUH)EXHAUST(CFM)OWNERFURNISHEDOWNERINSTALLEDCONTRACTORFURNISHEDCONTRACTORINSTALLEDCOMMENTSHEIGHT(IN)WIDTH(IN)DEPTH(IN)WEIGHT(LBS)NORMALVOLTAGE(VAC)PHASEHzPOWER DRAWEMERGENCYPOWERPLUG TYPE(SEE NOTE 1)DCWDHWPCWLABDRAINLABVENTRODIGASPROPANEVACCA 85PSICALPTEMP (*F)HUMIDITY %VIBRATIONSENSITIVEAMPSHPWATTSA(1)MILL DRILLLITTLEMACHINESHOPHITORQUEMINI MILLBENCH36.323.219.71241201608.67--------------XXB(1)3D PRINTERMARKFORGEDMARK TWO(GEN 2)BENCH142313351201602150--------------XXC(1)3D PRINTERPRUSAI3 MK3S+BENCH18.92120.524.360120--------------XXD(1)DRILL PRESSJET716250FLOOR63.251727172120160.75--------------XXE(1)BANDSAWJET414504CFLOOR73.525.522.382802303603.61---------------XXXCONTRACTOR TO CONNECT MOTOR TO POWERSOURCE. SEE ELECTRICAL DRAWINGS.F(1)LASER CUTTEREPILOGFUSIONEDGE 2480-WATTFILTRATIONBOX38.0441.5232.81225120160--------------350-400XXXCONTRACTOR TO INTERLOCK WITH FILTRATIONBASE AND COMMISSION.G(1)WATERJETOMAXPROTOMAXFLOOR56.541.539.5750230-240160305-L14-30X---------50-90<95-XXH(1)DC POWER SUPPLYKEYSIGHT TECHNOLOGIESN8926ABENCH5.317.730.159208360-----------32-11380-XXI(1)THUMB LEVER AIR GUNCA HOSE-------------------------XXREFER TO PLUMBING DRAWINGSJ(1)FILTRATION BOXBOFAAD BASE 2ORACLEFLOOR21.6541.7431.89207120160121100--------------XXXCONTRACTOR TO INTERLOCK WITH LASERCUTTER AND COMMISSION.K(2)METAL TOOL STORAGE PEGBOARDWALLMOUNTED4242------------------------XXCOLOR: WHITEL(1)TALL STORAGE CABINETMOTT6535760FLOOR844822-----------------------XXWOOD VENEER DOORS AND PAINTED STEELCABINET BODY TO MATCH EXISTING CASEWORKM(1)TALL STORAGE CABINETMOTTSIM TO6530030-80FLOOR844822-----------------------XXWOOD VENEER DOORS AND PAINTED STEELCABINET BODY TO MATCH EXISTING CASEWORK.GLASS FRAMED DOORS.N(1)COAT RACKWALLMOUNTED5.5345/4-----------------------XXWOOD SPECIES AND FINISH MATCHED TOEXISTING CASEWORKO(3)UNDERSHELF LIGHT FIXTUREMOTTTLW0024SHELF-24-----------------XXP(4)MOBILE BASE CABINET, NICFLOOR-----------------------XXQ(4)WORK TABLE, NICFLOORADJ.6030-----------------------XXADJUSTABLE HEIGHTR(6)LAB CHAIR, NICFLOOR-----------------------XXS(2)MOBILE, POWERED LAPTOPWORKSTATION, NICFLOORADJ.6030----------------XXT(4)LOUNGE CHAIR, NICFLOOR-----------------------XXU(1)COFFEE TABLE, NICFLOOR-----------------------XXV(1)MAPLE WORKSURFACE, NICBENCH-30-----------------------XXW(3)STEEL CABINET, NICFLOOR303027.75-----------------------XXX(2)LAB STOOL, NICFLOOR-----------------------XXY(1)MOBILE WORKTABLE, NICFLOOR364824-----------------------XXSTORAGE SHELF BELOWINDICATES EQUIPMENT KEYNOTE#LAB EQUIPMENT SCHEDULE NOTES:1. ELECTRICAL SUBCONTRACTOR TO CONFIRM PLUG TYPE WITH OWNER.1111 STEEL CABINET W/ DRAWERS, BOD: VIDMAR PRECONFIGURED CABINETS, OF/OISCHEDULED BASEMAPLE WORKSURFACE, OF/OI ALUMINUM STOREFRONT SYSTEMRACEWAY, SEE ELECTRICAL DRAWINGS466A3' - 5"W11A-601SALVAGED AND MODIFIED UNISTRUT CARRIER4' - 0"6"PUSH PLATE ACTIVATION SWITCHLIGHT SWITCH, SEE ELECTRICAL DRAWINGSPUSH BUTTON KILL SWITCH, SEE ELECTRICAL DRAWINGSEXISTING BASEREINSTALLED WALL SHELVING3' - 6"3' - 6"METAL PEGBOARD, COLOR: WHITE, OF/CIREINSTALLED WALL SHELVING3' - 6"3"VIF+/- 3' - 0"3"7' - 0"METAL PEGBOARD, COLOR: WHITE, OF/CISALVAGED AND MODIFIED UNISTRUT CARRIERVIF+/- 3' - 0"VIF+/- 3' - 0"EXISTING COUNTERTOP+/- 9' - 2"EXISTING CASEWORK+/- 9' - 0"EXISTING BASEWARDROBE CABINET W/O CLOTHES ROD, OF/CIREINSTALLED SHELVINGVIF+/- 3' - 0"7' - 0"4' - 0"7' - 0"RACEWAY, SEE ELETRICAL DRAWINGS3' - 5"SCHEDULED BASESTOREFRONT SYSTEM1A-601SIMW13' - 5"RACEWAY, SEE ELECTRICAL DRAWINGS3' - 6"OVERHEAD CHORD REEL, SEE ELECTRICAL DRAWINGS( 3' - 0" )EXISTING BASE BEYOND COLLAPSIBLE WATER DAM7' - 0"( 3' - 0" )EXISTING TO REMAIN WALL SHELVING( 18' - 0" )WORK TABLES, OF/OI FRP WALL PANELS8' - 0"8' - 0"(5) STAINLESS STEEL BOBRICK B-6827 HOOKS4' - 0"4' - 8"STORAGE CABINET W/ FRAMED GLASS DOORS AND (5) SHELVES, OF/CIEXISTING RACEWAY, SEE ELECTRICAL DRAWINGS4' - 0"COLLAPSIBLE WATER DAMSCHEDULED BASE3' - 6"4' - 0"FRP WALL PANEL(5) STAINLESS STEEL BOBRICK B-6827 HOOKS4' - 0"8' - 4"4' - 0"4' - 8"STOREFRONT SYSTEMEXISTING BASE BEYOND COLLAPSIBLE WATER DAM8' - 3"3' - 9"W11A-601SIMSALVAGED AND MODIFIED UNISTRUT CARRIEREXISTING BASE3' - 6"4' - 0"STOREFRONT TO ALIGN WITH DOOR FRAMESCHEDULED BASE466A5' - 2"COAT RACK, OF/CI24" H x 36" W MARKERBOARD WITH MARKER TRAY, BOD: CLARIDGE FPM14-0203-Z, COLOR: WHITESTOREFRONT SYSTEMVIF+/- 10' - 9"VIF+/- 8' - 0"3' - 0"VIF+/- 4' - 0"RELOCATED MARKERBOARD1' - 9"2' - 8"SAFETY GLASSES STORAGEROOM SIGNAGE, "A1"EXISTING LIGHT SWITCHES8' - 3"RELOCATED TELEPHONE JACK5' - 0"W11A-6019"5' - 4"PUSH PLATE ACTIVATION SWITCHBREAK GLASS MANUAL SHUTOFF, SEE MECHANICAL DRAWINGS6"4' - 3"4' - 0"These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions6/7/2021 1:29:10 PMBIM 360://20625.03 Cornell University Upson Hall Room 466/Upson Hall 466-ARCH-R20.rvt20625.03SDFInterior ElevationsCREAD/CREA-420100% ConstructionDocumentsCornell UniversityUpson Hall 466 Lab RenovationIthaca, NYJune 1, 20211/4" = 1'-0"1Interior Elevation -Maker Space North1/4" = 1'-0"2Interior Elevation -Maker Space East1/4" = 1'-0"3Interior Elevation -Dirty Work Area South1/4" = 1'-0"4Interior Elevation -Dirty Work Area West1/4" = 1'-0"5Interior Elevation -Rm 466 North1/4" = 1'-0"6Interior Elevation Rm 466 East1/4" = 1'-0"7Interior Elevation -Rm 466 South MISCELLANEOUS FINISH REQUIREMENTS TO WALLS, FLOORS & CEILINGS IN AREAS AFFECTED BY DEMO HAVE NOT BEEN TOTALLY INCORPORATED INTO THE ROOM FINISH SCHEDULE. REFER TO DEMOLITION, FLOOR & REFLECTED CEILING PLANS FOR EXTENT OF "CUTTING & PATCHING". PATCHING SHALL BE THE REPAIR WORK REQUIRED TO RESTORE SURFACES TO THE ORIGINAL CONDITION AND/OR MATCHING THE ADJACENT SURFACES.FLOORING TO RUN BENEATH ANY OPEN SPACES IN ROOMS, INCLUDING ADA CABINETS & APPLIANCES IN THE ROOM FINISH SCHEDULE -"ETR" INDICATES EXISTING TO REMAINPAINT ALL EXPOSED HVAC, PLUMBING & ELECTRICAL CONSTRUCTION TO MATCH ADJACENT OR BACKGROUND SURFACES UNLESS OTHERWISE NOTED, INCLUDING BUT NOT LIMITED TO STEEL GRILLES, DIFFUSERS, REGISTERS, AND LOUVERS. DO NOT PAINT OPERATIONAL COMPONENTS OF SYSTEMS INCLUDING BUT NOT LIMITED TO SPRINKLER HEADS, FIRE, SMOKE, OR HEAT DETECTORS.REFER TO NOTES IN INTERIOR FINISHES & MATERIALS LIST FOR SOFFIT PAINT COLORSPAINT HOLLOW METAL FRAMES & DOORS PT-3 UNLESS OTHERWISE INDICATED. ALL GYPSUM BOARD CEILINGS TO BE FLAT FINISH UNLESS OTHERWISE NOTEDALL PAINTED VERTICAL SURFACES (WALLS, SOFFITS, COLUMNS, ETC ) TO BE AN EGGSHELL FINISH UNLESS OTHERWISE NOTED.GENERAL FINISH NOTESA.B.C.D.F.H.I.J.K.FINISH LEGENDSECTION 06 64 00 -PLASTIC PANELINGFIBER REINFORCED PLASTIC (FRP)CRANE COMPOSITES, FIRE-X GLASBORD -EMBOSSED TEXTURE -SURFASEAL FINISH, THICKNESS: 0.09", PANEL DIMENSION: 4'X8', COLOR: WHITE 85, ALL COORDINATING TRIM TO BE MANUFACTURER'S STANDARD MOLDING, FM APPROVED.SECTION 09 91 23 -INTERIOR PAINTINGPAINT (PT)-ALL DOORS, FRAMES AND TRIM –SEMI-GLOSS-CEILINGS –FLAT-ALL PAINTED VERTICAL SURFACES (WALLS, SOFFITS, COLUMNS, ETC) TO BE AN EGGSHELL FINISH.-AT EXPOSED CEILING USE DRYFALL PAINT.PT-1BENJAMIN MOORE -LOW VOC, COLOR: SNOW WHITE (WHITE), FINISH: EGGSHELL (WALLS)PT-2BENJAMIN MOORE -LOW VOC, COLOR: SNOW WHITE (WHITE), FINISH: FLAT (CEILINGS AND SOFFITS)PT-3BENJAMIN MOORE -LOW VOC, COLOR: WINTER SOLSTICE 1605 (MED GRAY), FINISH: SEMI-GLOSS (TRIM, HM DOORS & FRAMES)1. PAINT EXISTING DOOR & FRAME PT-3ROOM FINISH SCHEDULE REMARKSSECTION 09 65 13 -RESILIENT BASERUBBER BASERB-1ALLSTATE RUBBER, COVE RUBBER BASE, 4" HIGH, COLOR: #D49SECTION 12 35 51 -LABORATORY CASEWORK (OF/CI)WOOD & METAL CASEWORK (OF/CI)MOTT MANUFACTURING, SCIENCE LABORATORY FURNITURE, COLOR & WOOD SPECIES TO MATCH EXISTING CASEWORK IN 466. DOOR FRONTS TO HAVE WOOD VENEER.INSTALL SHALL BE COORDINATED BY CONTRACTOR.FINISHFLOORSEE DOOR SCHEDULE2"SLIDING W/ DOUBLE LITEFG26"4"SCHEDULESEE DOOR2"2"3' - 7 1/2"MANUFACTURERPACKAGE HEIGHT PEREMERGENCY BREAKOUT SLIDING DOOR ONLY, REFER TO FLOOR PLAN FOR LOCATION3' - 0"PUSH PLATE ACTIVATION SWITCH MOUNTED ON FRAME J1ACCESS COVER4 1/2"6"SEE DOOR SCHEDULE4 1/2"+/- 1 3/4"TERMINATE WITH L-BEAD AND SEALANT, TYPPARTITIONSCHEDHEADER ABOVESHIM SPACETERMINATE WITH L-BEAD AND SEALANT, TYPDOUBLE STUD, JAMB STUDS TO BE HEAVY DUTY STUDS 6x3 16gaSHIM SPACELABMAKER SPACEFINISHED FLOORPARTITIONSCHEDULED1/4"HEAVY DUTY STUD HEADER, REFER TO DETAIL 2/A-601LABMAKER SPACEEXISTING PARTITONKEY SWITCH TO BE LOCATED ON MAKER SPACE SIDE OF FRAME10"6"0000BRAILLE, MATCH EXISTING COLORCOLOR: MATCH EXISTINGRAISED LETTERING, FONT TO MATCH EXISTING (WHITE)A13/8"1/2"1"7/8"SQUARE END CAPS, MATCH EXISTING1/4" RULE PAINTED, MATCH EXISTINGSIGNBAND WITH INSERT SLOT, MATCH EXISTING1"1' - 6"1' - 6"CLEAR FLOOR AREA CENTERED ON RAISED CHARACTERSEQEQEQ8' - 3"4' - 0"2"2"2"2"W1S-1S-1S-1GLAZING TYPES:S-11/4" SAFETY GLASSMAKER SPACE466ALAB466CONSTRUCTIONEXISTING3' - 5 3/4"R.O.4' - 0 1/2"SCHEDULED BASEFINISHED FLOOR6" CFMF PARTITION5/8" GYPSUM BOARD, EACH SIDESOUND ATTENUATIONBLANKETS1"2 1/2"WOOD BLOCKING5/4 X HARDWOOD STOOL, FINISH TO MATCH WOOD VENEER OF EXISTING CASEWORK ALUMINUM STOREFRONT SYSTEMWOOD BLOCKINGWRAP GYPSUM BOARD TO FRAME, TERMINATE WITH L-BEAD AND SEALANTBACKER ROD & SEALANTSHIM WITH SEALANT EACH SIDEA-6012A-6012RECONSTRUCT PORTION OF GYPSUM BOARD SOFFIT, 5/8" GYPSUM BOARD ON 1 5/8" METAL STUD, VERIFY EXISTING CONSTRUCTION IN FIELDL-BEADL-BEADMODIFY, REPAIR AND PATCH EXISTING GYPSUM BOARD CEILING TO ACCOMMODATE PARTITIONPATCH AND REPAIR FIREPROOFING WHERE DISTRUBED BY NEW CONSTRUCTIONLINE OF STRUCTURE, EXISTING 2-HOUR FIRE-RATED CONCRETE SLAB AND METAL DECK FLOOR (WITH SPRAY-ON-FIREPROOFING)SALVAGED OVERHEAD CARRIER, 1 5/8" UNISTRUT COMPONENTS+/- 7' - 6"VIF+/- 4' - 2"A-6014TYPEXIST SLAB ON DECK(2) HEAVY DUTY STUD 6x3 16ga HEADER W/ HEAVY DUTY STUD CLIP CONNECTOR @ JAMBS. JAMB STUDS TO BE (1) HEAVY DUTY STUD 6x3 16ga, TYP AT ALL CFMF WALL OPENINGS (BOD: CLARK-DIETRICH)6" CFMF DEFLECTION TRACK W/ HILTI X-C PAF FASTENERS AT 12" OC MAX TO LOW DECK FLUTE W/ 1" MIN EMBEDMENT, TYPSPRAY-ON-FIREPROOFING FOLLOWING INSTALLATION OF METAL FRAMINGREMOVE INDICATED PORTION GYPSUM BOARD SOFFIT AND METAL FRAMINGREMOVE PORTION OF GYPSUM BOARD CEILING TO ACCOMMODATE PARTITIONVIF+/- 8"+/- 1' - 4"REMOVE AND SALVAGE OVERHEAD UNISTRUT CARRIER, REFER TO DEMOLITION PLANFIREPROOFINGLINE OF STRUCTURE, EXISTING 2-HOUR FIRE-RATED CONCRETE SLAB AND METAL DECK FLOOR.REMOVE PORTION OF GYPSUM BOARD CEILING AS REQUIRED TO REMOVE AND SALVAGE OVERHEAD UNISTRUT CARRIEREXIST SLAB ON DECKSALVAGED OVERHEAD CARRIER, 1 5/8" UNISTRUT COMPONENTS (MAX ALLOWABLE LOAD = 50 PLF EA TRACK, TYP OF (2))L5X4X5/16 CLIP ANGLE LLV SPANNING BETWEEN (2) RIBS OF EXIST METAL DECK W/ (2) 1/2" DIA HILTI KWIK TZ EXPANSION ANCHORS W/ 2" EMBEDMENT (NOT TO EXCEED 3-1/2").FASTEN UNISTRUT CARRIER W/ (2) 1/2" DIA BOLTS USING SPRING NUTS AS NECESSARYThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions6/7/2021 1:29:11 PMBIM 360://20625.03 Cornell University Upson Hall Room 466/Upson Hall 466-ARCH-R20.rvt20625.03SDFDetails & SchedulesCRECREA-601100% ConstructionDocumentsCornell UniversityUpson Hall 466 Lab RenovationIthaca, NYJune 1, 2021ROOM FINISH SCHEDULEROOMNUMBERROOM NAMEFLOORBASEWALLCEILINGFINISHREMARKSROOMNUMBERMATERIAL/ FINISHMATERIAL/ FINISHNORTHSOUTHEASTWESTMATERIALFINISHMATERIALFINISHMATERIALFINISHMATERIALFINISHLEVEL 4466LABEX-CONC./ETRRESETR-RB/RB-1ETR GWBPT-1ETR GWB/ GWBPT-1ETR GWB/ GWBPT-1ETR GWBPT-1ETR-GWB/PT-21466466AMAKER SPACEEX-CONC./ETRRESETR-RB/RB-1ETR GWB/ GWBPT-1ETR GWBPT-1ETR GWBPT-1ETR GWB/ GWBPT-1ETR-GWB/PT-2466ADOOR SCHEDULEDOOR #DOORFRAMEHARDWARELABELTHRESHOLDREMARKSDOOR #LEAFSSIZETYPEMATERIALFINISHGLASSELEVATIONTYPEMATERIALFINISHWIDTHHEIGHTTHICKLEVEL 4466A7' - 0"7' - 5 3/4"1 3/4"FG2ALUMCLEARANODIZEDS-1PER MFRJ1ALUMCLEARANODIZEDSEE SPEC ONA-602--466ADOOR TYPESHEAD AND JAMB DETAILSSIGN TYPESIGN LOCATION AT DOORSTOREFRONT SCHEDULE3/4" = 1'-0"1Typical Wall SectionNot To Scale2TOP OF CFMF WALL DETAIL3/4" = 1'-0"3Demolition Detail -Maker Space Soffit7' -0"3/4" = 1'-0"4UNISTRUT FRAME ANCHORAGE DETAIL SECTION 07 92 00 JOINT SEALANTS1. PRODUCT: MILDEW RESISTANT SILICONE SEALANTA. MANUFACTURER: DOW CORNINGB. PRODUCT: 786 MILDEW RESISTANTC. COLOR: TO BE SELECTED FROM MANUFACTURER'S FULL RANGESPECIFICATIONS:SECTION 02 70 00 SELECTIVE DEMOLITION1.SUMMARYA. DEMOLISH AND REMOVE SELECTED PORTIONS OF BUILDING.B. DISCONNECT AND CAP OR SEAL UTILITIES PRIOR TO DEMOLITION.C. MAINTAIN AND PROTECT ALL EXISTING UTILITY SERVICES.2. DEMOLITIONA. INSTALL TEMPORARY DUSTPROOF PARTITIONS AND ENCLOSURES.B. PATCH AND REPAIR DAMAGED SURFACES CAUSED BY SELECTIVE DEMOLITION OPERATIONS.C. DEMOLISHED MATERIALS BECOME CONTRACTOR'S PROPERTY, UNLESS OTHERWISE INDICATED.3. DISPOSAL OF DEMOLISHED MATERIALS:A. BURNING: NOT PERMITTED.B. DISPOSAL: OFF OWNER'S PROPERTY.4. SELECTIVE DEMOLITION SCHEDULEA. COORDINATE WITH OWNER'S REPRESENTATIVE FOR UTILITY SHUTDOWNS5. OCCUPANCYA. AREAS ADJACENT TO THE AREAS OF DEMOLITION MAY BE OCCUPIED. WORK IS TO BE CONDUCTED IN SUCH A MANNER AS TO MINIMIZE THE DISRUPTION OF NORMAL OPERATIONS.6. CONDITIONS OF STRUCTURESA. THE OWNER ASSUMES NO RESPONSIBILITY FOR ACTUAL CONDITIONS OF ITEMS OR STRUCTURES TO BE DEMOLISHED. CONDITIONS EXISTING AT THE TIME OF COMMENCEMENT OF CONTRACT WILL BE MAINTAINED BY THE OWNER INSOFAR AS IS PRACTICAL. HOWEVER, VARIATIONS WITHIN THE STRUCTURE MAY OCCUR BY THE OWNER'S REMOVAL AND SALVAGE OPERATIONS PRIOR TO START OF SELECTIVE DEMOLITION WORK.7. DAMAGESA. THE CONTRACTOR IS TO PROMPTLY REPAIR ALL DAMAGES CAUSED TO ADJACENT FACILITIES AND EQUIPMENT BY DEMOLITION WORK AT NO ADDITIONAL COST TO OWNER.SECTION 09 91 23 INTERIOR PAINTING (CONTINUED)6. CLEANING AND PROTECTIONA. AT END OF EACH WORKDAY, REMOVE RUBBISH, EMPTY CANS, RAGS AND OTHER DISCARDED MATERIALS FROM PROJECT SITE.B. AFTER COMPLETING PAINTING APPLICATION, CLEAN SPATTERED SURFACES. REMOVE SPATTER PAINTS BY WASHING, SCRAPING OR OTHER METHODS. DO NOT SCRATCH OR DAMAGE ADJACENT FINISHED SURFACES.C. PROTECT WORK OF OTHER TRADES AGAINST DAMAGE FROM PAINT APPLICATION. CORRECT DAMAGE TO WORK OF OTHER TRADES BY CLEANING, REPAIRING, REPLACING AND REFINISHING, AS APPROVED BY ARCHITECT, AND LEAVE IN AN UNDAMAGED CONDITION.D. AT COMPLETION OF CONSTRUCTION ACTIVITIES OR OTHER TRADES, TOUCH UP AND RESTORE DAMAGED OR DEFACED PAINTED SURFACES.7. INTERIOR PAINTING SCHEDULE• GYPSUM BOARD: PROVIDE THE FOLLOWING FINISH SYSTEMS OVER INTERIOR GYPSUM BOARD SURFACES:a. SEMIGLOSS ACRYLIC ENAMEL FINISH: TWO FINISH COATS OVER A PRIMER• PRIMER: INTERIOR GYPSUM BOARD PRIMER• FINISH COATS: WATERBORNE ACRYLIC EPOXY.• FERROUS METAL: PROVIDE THE FOLLOWING FINISH SYSTEMS OVER FERROUS METAL:a. SEMIGLOSS ACRYLIC-ENAMEL FINISH: TWO FINISH COATS OVER A PRIMER• PRIMER: INTERIOR FERROUS-METAL PRIMER• FINISH COATS: INTERIOR SEMIGLOSS ACRYLIC ENAMELSECTION 06 10 53 MISCELLANEOUS ROUGH CARPENTRY1. PRODUCT: NAILERS, BLOCKING & BACKING PANELSA. LUMBER STANDARDS AND GRADE STAMPS: PS 20, AMERICAN SOFTWOOD LUMBER STANDARD AND INSPECTION AGENCY GRADE STAMPS.B. FIRE-RETARDENT TREATMENT: AWPA C20 FOR LUMBER AND AWPA C27 FOR PLYWOOD; NONCORROSIVE TYPEC. DIMENSION LUMBER: HEM-FIR, SELECT STRUCTURAL NO. 2SECTION 09 65 13 RESILIENT BASE AND ACCESSORIES1. PRODUCTS:AS INDICATED IN FINISH SCHEDULE.2. ADHESIVES: WATER-RESISTANT TYPE RECOMMENDED BY RESILIENT-PRODUCT MANUFACTURER FOR RESILIENT PRODUCTS AND SUBSTRATE CONDITIONS INDICATED.3. RESILIENT BASE INSTALLATIONA. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR INSTALLING RESILIENT BASE.B. APPLY RESILIENT BASE TO WALLS, COLUMNS, PILASTERS, CASEWORK AND CABINETS IN TOE SPACES, AND OTHER PERMANENT FIXTURES IN ROOMS AND AREAS WHERE BASE IS REQUIRED.C. INSTALL RESILIENT BASE IN LENGTHS AS LONG AS PRACTICAL WITHOUT GAPS AT SEAMS AND WITH TOPS OF ADJACENT PIECES ALIGNED.D. TIGHTLY ADHERE RESILIENT BASE TO SUBSTRATE THROUGHOUT LENGTH OF EACH PIECE, WITH BASE IN CONTINUOUS CONTACT WITH HORIZONTAL AND VERTICAL SUBSTRATES.E. JOB-FORMED CORNERS:USE STRAIGHT PIECES OF MAXIMUM LENGTHS POSSIBLE AND FORM WITH RETURNS NOT LESS THAN 3 INCHES IN LENGTH.MITER OR COPE CORNERS TO MINIMIZE OPEN JOINTS.4. RESILIENT ACCESSORY INSTALLATIONA. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR INSTALLING RESILIENT ACCESSORIES.B. RESILIENT MOLDING ACCESSORIES: BUTT TO ADJACENT MATERIALS AND TIGHTLY ADHERE TO SUBSTRATES THROUGHOUT LENGTH OF EACH PIECE. INSTALL REDUCER STRIPS AT EDGES OF FLOOR COVERING THAT WOULD OTHERWISE BE EXPOSED.5. CLEANING AND PROTECTIONA. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR CLEANING AND PROTECTING RESILIENT PRODUCTS.B. REMOVE ADHESIVE AND OTHER BLEMISHES FROM SURFACES OPERATIONS IMMEDIATELY AFTER COMPLETING RESILIENT-PRODUCT INSTALLATION.C. PROTECT RESILIENT PRODUCTS FROM MARS, MARKS, INDENTATIONS, AND OTHER DAMAGE FROM CONSTRUCTION OPERATIONS AND PLACEMENT OF EQUIPMENT AND FIXTURES DURING REMAINDER OF CONSTRUCTION PERIOD.D. COVER RESILIENT PRODUCTS SUBJECT TO WEAR AND FOOT TRAFFIC UNTIL SUBSTANTIAL COMPLETION.SECTION 12 35 51 LABORATORY CASEWORK (OF/CI)SECTION 09 91 23 INTERIOR PAINTING1. PRODUCTS: A. GENERAL:a. MATERIALS FOR USE WITHIN EACH PAINT SYSTEM SHALL BE COMPATIBLE WITH ONE ANOTHER AND SUBSTRATES INDICATED, UNDER CONDITIONS OF SERVICE AND APPLICATION AS DEMONSTRATED BY MANUFACTURER, BASED ON TESTING AND FIELD EXPERIENCEb. FOR EACH COAT IN A PAINT SYSTEM, PRODUCTS SHALL BE RECOMMENDED IN WRITING BY TOPCOAT MANUFACTURERS FOR USE IN PAINT SYSTEM AND ON SUBSTRATE INDICATED.B. INTERIOR PRIMERS:a. INTERIOR GYPSUM BOARD PRIMER: FACTORY-FORMULATED LATEX-BASED PRIMER FOR INTERIOR APPLICATION• BENJAMIN MOORE; MOORCRAFT SUPER SPEC LATEX ENAMEL UNDERCOATER & PRIMER SEALER 253; APPLIED AT A DRY FILM THICKNESS OF NOT LESS THAN 1.2 MILS.b. INTERIOR FERROUS-METAL PRIMER: FACTORY-FORMULATED QUICK-DRYING RUST-INHIBITIVE ALKYD-BASED METAL PRIMER• BENJAMIN MOORE; MOORCRAFT SUPER SPEC ALKYD ENAMEL UNDERBODY AND PRIMER SEALER C245; APPLIED AT A DRY FILM THICKNESS OF NOT LESS THAN 1.5 MILS. C. INTERIOR FINISH COATS:a. INTERIOR FLAT ACRYLIC PAINT: FACTORY-FORMULATED FLAT LATEX PAINT FOR INTERIOR APPLICATION• BENJAMIN MOORE: MOORCRAFT SUPER SPEC LATEX FLAT 275: APPLIED AT A DRY FILM THICKNESS OF NOT LESS THAN 1.2 MILS.b. INTERIOR SEMIGLOSS ACRYLIC ENAMEL: FACTORY-FORMULATED SEMIGLOSS LATEX ENAMEL FOR INTERIOR APPLICATION:• BENJAMIN MOORE: MOORCRAFT SUPER SPEC LATEX SEMI-GLOSS ENAMEL 276: APPLIED AT A DRY FILM THICKNESS OF NOT LESS THAN 1.2 MILS.2. SUBMITTALSA. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INCLUDE PREPARATION REQUIREMENTS AND APPLICATION INSTRUCTIONS.3. EXAMINATION:A. EXAMINE SUBSTRATES AND CONDITIONS, WITH APPLICATOR PRESENT, FOR COMPLIANCE WITH REQUIREMENTS FOR MAXIMUM MOISTURE CONTENT AND OTHER CONDITIONS AFFECTING PERFORMANCE OF THE WORK.B. GYPSUM BOARD SUBSTRATES: VERIFY THAT FINISHING COMPOUND IS SANDED SMOOTHC. VERIFY SUITABILITY OF SUBSTRATES, INCLUDING SURFACE CONDITIONS AND COMPATIBILITY, WITH EXISTING FINISHES AND PRIMERS.D. PROCEED WITH COATING APPLICATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTEDa. APPLICATION OF COATING INDICATES ACCEPTANCE OF SURFACES AND CONDITIONS4. PREPARATION:A. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS IN "MPI ARCHITECTURAL PAINTING SPECIFICATION MANUAL" APPLICABLE TO SUBSTRATES AND PAINT SYSTEMS INDICATED.B. REMOVE HARDWARE, COVERS, PLATES, AND SIMILAR ITEMS ALREADY IN PLACE THAT ARE REMOVABLE AND RE NOT TO BE PAINTED. IF REMOVAL IS IMPRACTICAL OR IMPOSSIBLE BECAUSE OF SIZE OR WEIGHT OF ITEM, PROVIDE SURFACE-APPLIED PROTECTION BEFORE SURFACE PREPARATION AND PAINTING.a. AFTER COMPLETING PAINTING OPERATIONS, USE WORKERS SKILLED IN THE TRADES INVOLVED TO REINSTALL ITEMS THAT WERE REMOVED. REMOVE SURFACE-APPLIED PROTECTION IF ANY.C. CLEAN SUBSTRATES OF SUBSTANCES THAT COULD IMPAIR BOND OF PAINTS, INCLUDING DUST, DIRT, OIL, GREASE AND INCOMPATIBLE PAINTS AND ENCAPSULANTS.a. REMOVE INCOMPATIBLE PRIMERS AND REPRIME SUBSTRATE WITH COMPATIBLE PRIMERS OR APPLY TIE COAT AS REQUIRED TO PRODUCE PAINT SYSTEMS INDICATED.D. CONCRETE SUBSTRATES: REMOVE RELEASE AGENTS, CURING COMPOUNDS, EFFLORESCENCE AND CHALK. DO NOT PAINT SURFACES IF MOISTURE CONTENT OR ALKALINITY OF SURFACES TO BE PAINTED EXCEEDS THAT PERMITTED IN MANUFACTURER'S WRITTEN INSTRUCTIONS.5. APPLICATION:A. APPLY PAINTS ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS AND TO RECOMMENDATIONS IN "MPI MANUAL"a. USE APPLICATORS AND TECHNIQUES SUITED FOR PAINT AND SUBSTRATE INDICATED.b. PAINT SURFACES BEHIND MOVABLE EQUIPMENT AND FURNITURE SAME AS EXPOSED SURFACESc. PAINT FRONT AND BACKSIDES OF ACCESS PANELS, REMOVABLE OR HINGED COVERS, AND SIMILAR HINGED ITEMS TO MATCH EXPOSED SURFACESd. DO NOT PAINT OVER LABELS OF INDEPENDENT TESTING AGENCIES OR EQUIPMENT NAME, IDENTIFICATION, PERFORMANCE RATING OR NOMENCLATURE PLATES.B. TINT EACH UNDERCOAT A LIGHTER SHADE TO FACILITATE IDENTIFICATION OF EACH COAT IF MULTIPLE COATS OF SAME MATERIAL ARE TO BE APPLIED. TINT UNDERCOATS TO MATCH COLOR OF TOPCOAT, BUT PROVIDE SUFFICIENT DIFFERENCE IN SHADE OF UNDERCOATS TO DISTINGUISH EACH SEPARATE COAT.C. IF UNDERCOATS OR OTHER CONDITIONS SHOW THROUGH TOPCOAT, APPLY ADDITIONAL COATS UNTIL CURED FILM HAS A UNIFORM PAINT FINISH, COLOR AND APPEARANCE.D. APPLY PAINTS TO PRODUCE SURFACE FILMS WITHOUT CLOUDINESS, SPOTTING, HOLIDAYS, LAPS, BRUSH MARKS, ROLLER TRACKING, RUNS, SAGS, ROPINESS OR OTHER SURFACE IMPERFECTIONS. CUT IN SHARP LINES AND COLOR BREAKS.E. PAINTING FIRE SUPPRESSION, PLUMBING, HVAC, ELECTRICAL, COMMUNICATION AND ELECTRONIC SAFETY AND SECURITY WORK:a. PAINT THE FOLLOWING WORK WHERE EXPOSED IN OCCUPIED SPACES:• EQUIPMENT, INCLUDING PANELBOARDS• UNINSULATED METAL PIPING• UNINSULATED PLASTIC PIPING• PIPE HANGERS AND SUPPORTS• METAL CONDUIT• PLASTIC CONDUIT• DUCT, EQUIPMENT AND PIPE INSULATION HAVING COTTON OR CANVAS INSULATION COVERING OR OTHER PAINTABLE JACKET MATERIAL• OTHER ITEMS AS DIRECTED BY ARCHITECTb. PAINT PORTIONS OF INTERNAL SURFACES OF METAL DUCTS, WITHOUT LINER, BEHIND AIR INLETS AND OUTLETS THAT ARE VISIBLE FROM OCCUPIED SPACES.SECTION 09 22 16 NON-STRUCTURAL METAL FRAMING1. STUDS AND RUNNERS: ASTM C 645A. MIN BASE-METAL THICKNESS: 0.027"a. EQUIVALENT COATINGS AND METAL THICKNESS (DIMPLED STEEL) STUDS WILL NOT BE ALLOWED.B. DEPTH: AS INDICATED ON DRAWINGSC. PROTECTIVE COATING: ASTM A 653/A 653M, G40, HOT-DIP GALVANIZEDSECTION 08 41 13 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS1. MANUFACTURERSA. EFCO CORPORATIONB. KAWNEER NORTH AMERICA; AN ALCOA COMPANYC. OLDCASTLE BUILDING ENVELOPE2. FRAMING MEMBERS: MANUFACTURER'S EXTRUDED-OR FORMED-ALUMINUM FRAMING MEMBERS OF THICKNESS REQUIRED AND REINFORCED AS REQUIRED TO SUPPORT IMPOSED LOADS.A. MEMBER SIZE: 2" x 4-1/2"B. CONSTRUCTION: NON-THERMALC. GLAZING SYSTEM: RETAINED MECHANICALLY WITH GASKETS ON FOUR SIDESD. GLAZING PANE: CENTERE. FINISH: CLEAR ANODIZEDF. FABRICATION METHOD: FIELD-FABRICATED STICK SYSTEM3. BACKER PANELS: MANUFACTURER'S STANDARD, CONTINUOUS BACKER PLATES FOR FRAMING MEMBERS, IF NOT INTEGRAL, WHERE FRAMING ABUTS ADJACENT CONSTRUCTION.4. BRACKET AND REINFORCEMENTS: MANUFACTURER'S STANDARD HIGH-STRENGTH ALUMINUM WITH NON-STAINING, NONFERROUS SHIMS FOR ALIGNING SYSTEM COMPONENTS.5. MATERIALS:A. ALUMINUM: ALLOY AND TEMPER RECOMMENDED BY MANUFACTURER FOR TYPE OF USE AND FINISH INDICATED.a. SHEET AND PLATE: ASTM B 209b. EXTRUDED BARS, RODS, PROFILES, AND TUBES: ASTM B 221c. EXTRUDED STRUCTURAL PIPE AND TUBES: ASTM B 429/B 429Md. STRUCTURAL PROFILES: ASTM B 308/B 308MB. STEEL REINFORCEMENT: MANUFACTURER'S STANDARD ZINC-RICH, CORROSION-RESISTANT PRIMER COMPLYING WITH SSPC-PS GUIDE NO 12.00; APPLIED IMMEDIATELY AFTER SURFACE PREPARATION AND PRE-TREATMENT. SELECT SURFACE PREPARATION METHODS ACCORDING TO RECOMMENDATION IN SSPC-SP COM, AND PREPARE SURFACES ACCORDING TO APPLICABLE SSPC STANDARD.a. STRUCTURAL SHAPES, PLATES, AND BARS: ASTM A 26/A 26Mb. COLD-ROLLED SHEET AND STRIP: ASTM A 1008/A 1008Mc. HOT-ROLLED SHEET AND STRIP: ASTM A 1011/A 1011M6. GLAZING: COMPLY WITH SECTION 08 80 00 "GLAZING."A. GLAZING GASKETS: MANUFACTURER'S STANDARD SEALED-CORNER PRESSURE-GLAZING SYSTEM OF BLACK, RESILIENT ELASTOMERIC GLAZING GASKETS, SETTING BLOCKS, AND SHIMS OR SPACERS.SECTION 08 80 00 GLAZING1. GLASS PRODUCTSA. FULLY TEMPERED FLOAT GLASS: ASTM C 1048, KIND FT (FULLY TEMPERED),CONDITION A (UNCOATED) UNLESS OTHERWISE INDICATED, TYPE 1, CLASS 1(CLEAR), QUALITY Q3.2. GLASS SCHEDULE:A. MONOLITHIC-GLASS (TYPE S-1)a. CLEAR FULLY TEMPERED FLOAT GLASSb. THICKNESS: 6.0 MM (0.25 INCH)c. PROVIDE SAFETY LABELING, 16 CFR 1201, CATEGORY IISECTION 09 29 00 GYPSUM BOARD1. GYPSUM BOARD, TYPE X: ASTM C1396/C1396M.1. LONG EDGES: TAPERED.2. SOUND-ATTENUATION BLANKETS: ASTM C665, TYPE I (BLANKETS WITHOUTMEMBRANE FACING) PRODUCED BY COMBINING THERMOSETTING RESINS WITHMINERAL FIBERS MANUFACTURED FROM GLASS, SLAG WOOL, OR ROCK WOOL.1. FIRE-RESISTANCE-RATED ASSEMBLIES: COMPLY WITH MINERAL-FIBERREQUIREMENTS OF ASSEMBLY.2. SURFACE-BURNING CHARACTERISTICS: COMPLY WITH ASTM E84; TESTING BY A QUALIFIED TESTING AGENCY.A. FLAME-SPREAD INDEX: 25 OR LESS.B. SMOKE-DEVELOPED INDEX: 50 OR LESS.3. ACOUSTICAL SEALANT: MANUFACTURER'S STANDARD NONSAG, PAINTABLE,NONSTAINING LATEX SEALANT COMPLYING WITH ASTM C834. PRODUCTEFFECTIVELY REDUCES AIRBORNE SOUND TRANSMISSION THROUGH PERIMETERJOINTS AND OPENINGS IN BUILDING CONSTRUCTION AS DEMONSTRATED BYTESTING REPRESENTATIVE ASSEMBLIES ACCORDING TO ASTM E90.4. GYPSUM BOARD FINISH LEVELS: FINISH PANELS TO LEVELS INDICATED BELOW ANDACCORDING TO ASTM C840:1. LEVEL 1: CEILING PLENUM AREAS, CONCEALED AREAS, AND WHEREINDICATED.2. LEVEL 4: AT PANEL SURFACES THAT WILL BE EXPOSED TO VIEW UNLESSOTHERWISE INDICATED.SECTION 10 14 00 SIGNS1. SUBMITTALSA. PRODUCT DATA: FOR EACH TYPE OF PRODUCT.B. SHOP DRAWINGS: FOR PANEL SIGNS.C. SAMPLES FOR INITIAL SELECTION: FOR EACH TYPE OF SIGN ASSEMBLY, EXPOSED COMPONENT, AND EXPOSED FINISH.a. INCLUDE REPRESENTATIVE SAMPLES OF AVAILABLE TYPESTYLES AND GRAPHIC SYMBOLS.D. SAMPLES FOR VERIFICATION: FULL-SIZE SAMPLE SHOWING ALL COMPONENTS AND WITH THE REQUIRED FINISH(ES)2. PANEL SIGNSA. PANEL SIGN: SIGN WITH SMOOTH, UNIFORM SURFACES; WITH MESSAGE AND CHARACTERS HAVING UNIFORM FACES, SHARP CORNERS, AND PRECISELY FORMED LINES AND PROFILES; AND AS FOLLOWS:B. SOLID-SHEET SIGN:ACRYLIC SHEET WITH FINISH SPECIFIED IN "SURFACE FINISH AND APPLIED GRAPHICS" SUBPARAGRAPH AND AS FOLLOWS:a. THICKNESS:MANUFACTURER'S STANDARD FOR SIZE OF SIGN.b. SURFACE-APPLIED, RAISED GRAPHICS: APPLIED POLYMER CHARACTERS AND BRAILLE.c. SIGN-PANEL PERIMETER: FINISH EDGES SMOOTH.d. CORNER CONDITION IN ELEVATION:SQUARE.e. MOUNTING:SURFACE MOUNTED TO WALL WITH ADHESIVE AND TWO-FACE TAPE.f. SURFACE FINISH AND APPLIED GRAPHICS:• INTEGRAL ACRYLIC SHEET COLOR:AS SELECTED BY ARCHITECT FROM FULL RANGE OF INDUSTRY COLORS.• TEXT AND TYPEFACE:ACCESSIBLE RAISED CHARACTERS AND BRAILLE AND VARIABLE CONTENT AS SCHEDULED.FINISH RAISED CHARACTERS TO CONTRAST WITH BACKGROUND COLOR, AND FINISH BRAILLE TO MATCH BACKGROUND COLOR. AS SELECTED BY ARCHITECT FROM FULL RANGE OF INDUSTRY COLORS.C. MATERIALSa. ACRYLIC SHEET: ASTM D 4802, CATEGORY AS STANDARD WITH MANUFACTURER FOR EACH SIGN, TYPE UVF (UV FILTERING).b. TWO-FACE TAPE: MANUFACTURER'S STANDARD HIGH-BOND, FOAM-CORE TAPE, 0.045 INCH THICK, WITH ADHESIVE ON BOTH SIDES.D. INSTALLATIONa. INSTALL SIGNS LEVEL, PLUMB, TRUE TO LINE, AND AT LOCATIONS AND HEIGHTS INDICATED, WITH SIGN SURFACES FREE OF DISTORTION AND OTHER DEFECTS IN APPEARANCE.E. SCHEDULEa. PROVIDE (1) SIGN FOR EACH DOOR NUMBERINDICATED ON PLANS.SECTION 07 84 13 PENETRATION FIRESTOPPINGA. FOR PENETRATIONS IN FIRE-RESISTANCE-RATED WALLS: PENETRATION FIRESTOPPING SYSTEMS WITH RATINGS DETERMINED PER ASTM E814 OR UL 1479, BASED ON TESTING AT A POSITIVE PRESSURE DIFFERENTIAL OF 0.01-INCH WG.1. F-RATING: NOT LESS THAN THE FIRE-RESISTANCE RATING OF CONSTRUCTIONSPENETRATED.2. FM APPROVEDB. ACCESSORIES: PROVIDE COMPONENTS FOR EACH PENETRATION FIRESTOPPINGSYSTEM THAT ARE NEEDED TO INSTALL FILL MATERIALS AND TO MAINTAIN RATINGSREQUIRED. USE ONLY THOSE COMPONENTS SPECIFIED BY PENETRATION FIRESTOPPING SYSTEM MANUFACTURER AND APPROVED BY QUALIFIED TESTING AND INSPECTING AGENCY FOR CONDITIONS INDICATED.1. PERMANENT FORMING/DAMMING/BACKING MATERIALS.2. SUBSTRATE PRIMERS.3. COLLARS.4. STEEL SLEEVES.C. INSTALL PENETRATION FIRESTOPPING SYSTEMS TO COMPLY WITH MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS AND PUBLISHED DRAWINGS FOR PRODUCTS AND APPLICATIONS.1. INSTALLATION SHALL BE BY AN FM APPROVED CONTRACTOR.D. INSTALL FILL MATERIALS BY PROVEN TECHNIQUES TO PRODUCE THE FOLLOWINGRESULTS:1. FILL VOIDS AND CAVITIES FORMED BY OPENINGS, FORMING MATERIALS,ACCESSORIES AND PENETRATING ITEMS TO ACHIEVE REQUIRED FIRE-RESISTANCE RATINGS.2. APPLY MATERIALS SO THEY CONTACT AND ADHERE TO SUBSTRATES FORMED BYOPENINGS AND PENETRATING ITEMS.3. FOR FILL MATERIALS THAT WILL REMAIN EXPOSED AFTER COMPLETING THE WORK, FINISH TO PRODUCE SMOOTH, UNIFORM SURFACES THAT ARE FLUSH WITHADJOINING FINISHES.1. PRODUCT: CABINETSA. MANUFACTURER: MOTT MANUFACTURINGB. PRODUCT: ARCHITECTURAL OVERLAY CABINETS WITH WOOD VENEER FRONTSC. CABINETS:a. CABINET SIDES: 18 GAb. TOP RAILS: 14 GAc. DOOR FRONTS: 18GAd. RUBBER BUMPERS/SILENCERSe. ADJUSTABLE SHELVES: 20GAf. PULLS: 4" STAINLESS STEEL WIRE PULLg. HINGES: STAINLESS STEEL OVERLAY HINGESh. WOOD VENEER: AWI PREMIUM BIRCH, ROTARY SLICED, BOOK MATCH, NATURAL (CLEAR) FINISHi. STEEL FINISH: POWDER COATEDD. BASE CABINETa. REMOVABLE BACK: 20 GAb. REAR RAIL: 16 GAc. DRAWER RUNNER SUPPORT: 14 GA GALVANIZEDd. DRAWER LINER: 20 GAe. ROLLER CATCHESf. 3/8" THREADED LEVELER PLATE: 11 GAg. DRAWER WITH INTEGRAL SIDES & BACK: 18 GA OR 20 GAh. ENCLOSED TOE SPACE: 18 GASECTION 08 42 29.23 SLIDING AUTOMATIC ENTRANCES1. PERFORMANCE REQUIREMENTSA. OPENING FORCE:a. POWER-OPERATED DOORS: NOT MORE THAN 50LBF REQUIRED TO MANUALLY SET DOOR IN MOTION IF POWER FAILS, AND NOT MORE THAN 15LBF REQUIRED TO OPEN DOOR TO MINIMUM REQUIRED WIDTH.b. BREAKAWAY DEVICE FOR POWER-OPERATED DOORS: NOT MORE THAN 50LBF REQUIRED FOR A BREAKAWAY DOOR OR PANEL TO OPEN.c. ENTRAPMENT-PREVENTION FORCE:• POWER-OPERATED SLIDING DOORS: NOT MORE THAN 30LBF REQUIRED TO PREVENT STOPPED DOOR FROM CLOSING.2. GENERAL:A. PROVIDEMANUFACTURER'S STANDARD AUTOMATIC ENTRANCES, INCLUDING DOORS, SIDELITES, FRAMING, HEADERS, CARRIER ASSEMBLIES, ROLLER TRACKS, DOOR OPERATORS, CONTROLS, AND ACCESSORIES REQUIRED FOR A COMPLETE INSTALLATION.3. SLIDING AUTOMATIC ENTRANCE: A. SINGLE-SLIDING UNITS:a. BASIS OF DESIGN: ASSA ABLOY BESAM SL500, OVERHEAD CONCEALED FIXED SIDELITE NARROW STILE SINGLE SLIDE DOOR SYSTEM.b. MANUFACTURERS:SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING:• BESAM ENTRANCE SOLUTIONS; AN ASSA ABLOY GROUP COMPANY.• HORTON AUTOMATICS; A DIVISION OF OVERHEAD DOOR CORPORATION.• STANLEY ACCESS TECHNOLOGIES.B. CONFIGURATION, SINGLE-SLIDING: SINGLE-SLIDING DOOR WITH ONE SLIDING LEAF AND SIDELITE.a. TRAFFIC PATTERN: TWO WAY.b. EMERGENCY BREAKAWAY CAPABILITY: SLIDING LEAF ONLY.c. MOUNTING: BETWEEN JAMBS.C. OPERATOR FEATURES:a. POWER OPENING AND CLOSING.b. DRIVE SYSTEM: BELT.c. ADJUSTABLE OPENING AND CLOSING SPEEDS.d. ADJUSTABLE HOLD-OPEN TIME BETWEEN ZERO AND 30 SECONDS.e. OBSTRUCTION RECYCLE.f. ON-OFF/HOLD-OPEN SWITCH TO CONTROL ELECTRIC POWER TO OPERATOR.D. SLIDING-DOOR CARRIER ASSEMBLIES AND OVERHEAD ROLLER TRACKS: CARRIER ASSEMBLY THAT ALLOWS VERTICAL ADJUSTMENT; CONSISTING OF NYLON-OR DELRIN-COVERED, BALL-BEARING-CENTER STEEL WHEELS OPERATING ON A CONTINUOUS ROLLER TRACK, OR BALL-BEARING-CENTER STEEL WHEELS OPERATING ON A NYLON-OR DELRIN-COVERED, CONTINUOUS ROLLER TRACK. SUPPORT DOORS FROM CARRIER ASSEMBLY BY CANTILEVER AND PIVOT ASSEMBLY.a. ROLLERS: MINIMUM OF TWO BALL-BEARING ROLLER WHEELS AND TWO ANTIRISE ROLLERS FOR EACH ACTIVE LEAF.E. SLIDING-DOOR THRESHOLD: THRESHOLD MEMBERS AND BOTTOM-GUIDE-TRACK SYSTEM WITH STAINLESS STEEL, BALL-BEARING-CENTER ROLLER WHEELS.a. CONFIGURATION, NO THRESHOLD: NO THRESHOLD ACROSS DOOR OPENING AND SURFACE-MOUNTED GUIDE-TRACK SYSTEM AT SIDELITES. F. CONTROLS: ACTIVATION AND SAFETY DEVICES ACCORDING TO BHMA STANDARDS.G. FINISH: FINISH FRAMING, DOOR(S), AND HEADER WITH CLASSI, CLEAR ANODIC FINISH.4. ENTRANCE COMPONENTS:A. FRAMING MEMBERS: EXTRUDED ALUMINUM, MINIMUM 0.125INCH THICK AND REINFORCED AS REQUIRED TO SUPPORT IMPOSED LOADS.a. NOMINAL SIZE: 1-3/4 BY 4-1/2INCHES.b. EXTRUDED GLAZING STOPS AND APPLIED TRIM: MINIMUM 0.062-INCH WALL THICKNESS.B. STILE AND RAIL DOORS: 1-3/4-INCH-THICK, GLAZED DOORS WITH MINIMUM 0.125-INCH-THICK, EXTRUDED-ALUMINUM TUBULAR STILE AND RAIL MEMBERS. MECHANICALLY FASTEN CORNERS WITH REINFORCING BRACKETS THAT ARE WELDED, OR INCORPORATE CONCEALED TIE-RODS THAT SPAN FULL LENGTH OF TOP AND BOTTOM RAILS.a. GLAZING STOPS AND GASKETS: BEVELED, SNAP-ON, EXTRUDED-ALUMINUM STOPS AND PREFORMED GASKETS.b. STILE DESIGN: AS INDICATED ON DRAWINGS.c. RAIL DESIGN: AS INDICATED ON DRAWINGS.C. SIDELITE(S): 1-3/4-INCH-DEEP SIDELITE(S) WITH MINIMUM 0.125-INCH-THICK, EXTRUDED-ALUMINUM TUBULAR STILE AND RAIL MEMBERS MATCHING DOOR DESIGN.a. GLAZING STOPS AND GASKETS: SAME MATERIALS AND DESIGN AS FOR STILE AND RAIL DOOR.D. HEADERS: FABRICATED FROM MINIMUM 0.125-INCH-THICK EXTRUDED ALUMINUM AND EXTENDING FULL WIDTH OF AUTOMATIC ENTRANCE UNITS TO CONCEAL DOOR OPERATORS AND CONTROLS. PROVIDE HINGED OR REMOVABLE ACCESS PANELS FOR SERVICE AND ADJUSTMENT OF DOOR OPERATORS AND CONTROLS. SECURE PANELS TO PREVENT UNAUTHORIZED ACCESS.a. MOUNTING: CONCEALED, WITH ONE SIDE OF HEADER FLUSH WITH FRAMING.b. CAPACITY: CAPABLE OF SUPPORTING DOORS OF UP TO 175LB PER LEAF OVER SPANS OF UP TO 14FEET WITHOUT INTERMEDIATE SUPPORTS• PROVIDE SAG RODS FOR SPANS EXCEEDING 14FEET.E. BRACKETS AND REINFORCEMENTS: HIGH-STRENGTH ALUMINUM WITH NONSTAINING, NONFERROUS SHIMS FOR ALIGNING SYSTEM COMPONENTS.F. SIGNAGE: AS REQUIRED BY CITED BHMA STANDARD.a. APPLICATION PROCESS: DOOR MANUFACTURER'S STANDARD PROCESS.SECTION 08 42 29.23 SLIDING AUTOMATIC ENTRANCES (CONTINUED)5. DOOR OPERATORS AND CONTROLSA. GENERAL: PROVIDE OPERATORS AND CONTROLS, WHICH INCLUDE ACTIVATION AND SAFETY DEVICES ACCORDING TO BHMA STANDARDS, FOR CONDITION OF EXPOSURE, AND FOR LONG-TERM, MAINTENANCE-FREE OPERATION UNDER NORMAL TRAFFIC LOAD TYPE FOR OCCUPANCY INDICATED.B. DOOR OPERATORS: PROVIDE DOOR OPERATORS OF SIZE RECOMMENDED BY MANUFACTURER FOR DOOR SIZE, WEIGHT AND MOVEMENT.a. DOOR OPERATOR PERFORMANCE: DOOR OPERATORS SHALL OPEN AND CLOSE DOORS AND MAINTAIN THEM IN FULLY CLOSED POSITION WHEN SUBJECTED TO PROJECT'S DESIGN LOADS.b. ELECTROMECHANICAL OPERATORS: CONCEALED, SELF-CONTAINED, OVERHEAD UNITS POWERED BY FRACTIONAL-HORSEPOWER, PERMANENT-MAGNET DC MOTOR; WITH CLOSING SPEED CONTROLLED MECHANICALLY BY GEAR TRAIN AND DYNAMICALLY BY BRAKING ACTION OF ELECTRIC MOTOR; WITH SOLID-STATE MICROPROCESSOR CONTROLLER; COMPLYING WITH UL 325; AND WITH MANUAL OPERATION WITH POWER OFF.C. PHOTOELECTRIC BEAMS: PULSED INFRARED, SENDER-RECEIVER ASSEMBLY FOR RECESSED MOUNTING. BEAMS SHALL NOT BE ACTIVE WHEN DOORS ARE FULLY CLOSED.a. INSTALL PHOTOELECTRIC BEAMS IN VERTICAL JAMBS OF SIDELITES WITH DIMENSION ABOVE FINISHED FLOOR AS FOLLOWS:• TOP BEAM: 48 INCHES• BOTTOM BEAM: 24 INCHESD. ACTIVATION SWITCH: PUSH PLATE ACTIVATION DOOR-CONTROL SWITCH; FACEPLATE WITH CONTRASTING-COLORED, ENGRAVED MESSAGE:a. FACEPLATE MATERIAL: STAINLESS STEELb. MOUNTING: DOOR FRAME JAMBc. SIZE: 1-1/2" WIDE X 4-3/4" HIGHd. MESSAGE: PUSH TO OPENe. SYMBOL: BLUE HANDICAP SYMBOLE. MICROPROCESSOR CONTROL BOX:a. MODE SELECTOR CONTROL:• MULTI-POSITION, KEYED CYLINDER SWITCH MODE SELECTOR SWITCH TO BE INTERIOR JAMB MOUNTED AND SHALL ALLOW SELECTION OF THE INDICATED FUNCTIONS TO BE ENGAGED WHEN SWITCH IS TURNED TO THE APPROPRIATE SETTING.b. MODE SELECTOR CONTROL TO ALLOW THE FOLLOWING FUNCTIONS:• "OFF"• "EXIT ONLY" ONE WAY TRAFFIC WITH AUTOMATIC OPERATION FROM THE INTERIOR• "TWO WAY TRAFFIC" ALLOWING AUTOMATIC OPERATION FROM EXTERIOR AND INTERIOR• "PARTIAL OPENING" ENERGY SAVING DOOR POSITION ALLOWS DOOR TO AUTOMATICALLY ADJUST OPENING WIDTH BASED ON AMOUNT OF USAGE; FULL OPEN DURING HIGH USE AND PARTIAL OPEN DURING LOW USE. THE CONTROL FOR THIS SETTING IS PROGRAMMABLE ALLOWING ADJUSTMENT TO BOTH THE USAGE SETTING AND THE OPENING WIDTH• "HOLD OPEN" DOORS ACTIVATED AND HELD IN THE FULL OPEN POSITION.6. HARDWAREA. GENERAL: PROVIDE UNITS IN SIZES AND TYPES RECOMMENDED BY AUTOMATIC ENTRANCE AND HARDWARE MANUFACTURERS FOR ENTRANCES AND USES INDICATED. FINISH EXPOSED PARTS TO MATCH DOOR FINISHUNLESS OTHERWISE INDICATED.B. BREAKAWAY DEVICE FOR POWER-OPERATED DOORS: DEVICE THAT ALLOWS DOOR TO SWING OUT IN DIRECTION OF EGRESS TO FULL 90 DEGREES FROM ANY OPERATING POSITION. MAXIMUM FORCE TO OPEN DOOR SHALL BE AS STIPULATED IN "PERFORMANCE REQUIREMENTS" ARTICLE. INTERRUPT POWERED OPERATION OF DOOR OPERATOR WHILE IN BREAKAWAY MODE.a. INCLUDE ONE ADJUSTABLE DETENT DEVICE MOUNTED AT THE TOP OF EACH BREAKAWAY PANEL TO CONTROL BREAKAWAY FORCE.• LIMIT ARMS: LIMIT SWING TO 90 DEGREES, SPRING LOADED WITH ADJUSTABLE FRICTION DAMPING.C. WEATHER STRIPPING: REPLACEABLE COMPONENTS.a. SLIDING TYPE: AAMA701/702, MADE OF WOOL, POLYPROPYLENE, OR NYLON WOVEN PILE WITH NYLON-FABRIC OR ALUMINUM-STRIP BACKING.7. DEMONSTRATIONA. ENGAGE A FACTORY-AUTHORIZED REPRESENTATIVE TO TRAIN OWNER'S MAINTENANCE PERSONNEL TO ADJUST, OPERATE, AND MAINTAIN SAFE OPREATION OF THE DOOR.SECTION 05 40 00 COLD-FORMED METAL FRAMING1. COLD-FORMED STEEL FRAMING STANDARDS: COMPLY WITH AISI S100, AISI S200, AISI S211 (WALL STUDS), AISI S212 (HEADERS) AND AISI S213 (LATERAL DESIGN)2. COLD-FORMED STEEL FRAMING MATERIALS:A. PROTECTIVE COATING: ASTM A 1003/A 1003/M, STRUCTURAL GRADE, TYPE H, METALLIC COATED, ST33H,G60 OR A60B. WALL STUDS: AISI S211a. MANUFACTURER'S STANDARD C-SHAPED STEEL STUDS, OF WEB DEPTHS INDICATED, UNPUNCHED, WITH UNSTIFFENED FLANGES.• MIN BASE-METAL THICKNESS: 0.0538"1. EQUIVALENT COATINGS AND METAL THICKNESS (DIMPLED STEEL) STUDS WILL NOT BE ALLOWED.• FLANGE WIDTH: 1-3/8"• DEPTH: AS INDICATED ON DRAWINGSC. STEEL TRACK:a. MANUFACTURER'S STANDARD U-SHAPED STEEL TRACK, OF WEB DEPTHS INDICATED, UNPUNCHED, WITH UNSTIFFENED FLANGES, AND AS FOLLOWS:• MIN BASE-METAL THICKNESS: MATCHING STEEL STUDS.• FLANGE WIDTH: 1-1/4"D. SINGLE DEFLECTION TRACK:a. MANUFACTURER'S SINGLE, DEEP-LEG, U-SHAPED STEEL TRACK; UNPUNCHED, WITH UNSTIFFENED FLANGES, OF WEB DEPTH TO CONTAIN STUDS WHILE ALLOWING FREE VERTICAL MOVEMENT, WITH FLANGES DESIGNED TO SUPPORT HORIZONTAL LOADS AND TRANSFER THEM TO THE PRIMARY STRUCTURE, AND AS FOLLOWS:• MIN BASE-METAL THICKNESS: 0.0538"• FLANGE WIDTH: 1" PLUS THE DESIGN GAP FOR ONE-STORY STRUCTURES.E. HEADERS: AISI S212a. MANUFACTURER'S STANDARD C-SHAPERS USED TO FORM HEADER BEAMS OF WEB DEPTHS INDICATED, UNPUNCHED, WITH STIFFENED FLANGES.• MIN BASE-METAL THICKNESS: 0.0538"• EQUIVALENT COATINGS AND METAL THICKNESS (DIMPLED STEEL) STUDS WILL NOT BE ALLOWED.• FLANGE WIDTH: 1-3/8"• DEPTH: AS INDICATED ON DRAWINGSF. FRAMING ACCESSORIESa. FABRICATE STEEL-FRAMING ACCESSORIES FROM ASTM A 1003/A 1003M, STRUCTURAL GRADE, TYPE H, METALLIC COATED STEEL HEET, OF SAME GRADE AND COATING DESIGNATION USED FOR FRAMING MEMBERS.b. PROVIDE ACCESSORIES OF MANUFACTURER'S TANDARD THICKNESS AND CONFIGURATION, UNLESS OTHERWISE INDICATED.These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions6/7/2021 1:29:12 PMBIM 360://20625.03 Cornell University Upson Hall Room 466/Upson Hall 466-ARCH-R20.rvt20625.03SDFSpecificationsCRECREA-602100% ConstructionDocumentsCornell UniversityUpson Hall 466 Lab RenovationIthaca, NYJune 1, 2021 WALL HYDRANT (WH) / HOSE BIBB (HB) VENT PIPING UNION CHECK VALVE BALANCING VALVE SHUT OFF VALVE INDIRECT WASTE PIPING (IW)IW FLOOR DRAIN (FD) / FLOOR SINK (FS) CLEANOUT (CO) WALL PLATE CLEANOUT (WPCO) DECK PLATE CLEANOUT (DPCO) CAP OR PLUG PIPE CONTINUATION "P" TRAP TOP TEE CONNECTION BOTTOM/TEE CONNECTION ELBOW UP 45°OFFSET ELBOW DOWN DESCRIPTION PLUMBING SYMBOL LIST SYMBOL COMPRESSED AIR PIPING (CA)CA NATURAL GAS PIPING (G)G ST STORM WATER SEWER PIPING (ST) STRAINER SANITARY SEWER PIPINGSAN TEMPERED HOT WATER RETURN PIPING (TWR)TWR TEMPERED HOT WATER PIPING (TW)TW HOT WATER RECIRCULATING PIPING (HWR) HOT WATER PIPING (HW) COLD WATER PIPING (CW) NEW PIPING LOCATED BELOW FLOOR/SLAB NEW PIPING LOCATED ABOVE FLOOR/SLAB (E)EXISTING PIPING EC ELECTRICAL CONTRACTOR PC PLUMBING CONTRACTOR MC MECHANICAL CONTRACTOR GC GENERAL CONTRACTOR VTR VENT THRU ROOF BFF BELOW FINISHED FLOOR AFF ABOVE FINISHED FLOOR (ETR)EXISTING TO REMAIN (E)EXISTING NTS NOT TO SCALE POINT OF DISCONNECTION POINT OF CONNECTION EXISTING WORK TO BE REMOVED ST(S) SECONDARY STORM WATER SEWER PIPING (ST(S) 8 6.1 56 G F 1 1/2" V PIPING UP 2" PIPING UP TO FD 2"SANCONNECT TO (E)2" SAN (E)2 1/2" V UP & DN COORDINATE WITH FACILITY COORDINATOR AT LEAST THREE WEEKS IN ADVANCE FOR THIS WORK. LAB 366 8 6.1 56 G F (E)CA(E)3/4" ●●● (E)2" SAN, (E)1/2" HW & (E)1/2" CW TO (E)SINK. (E)2" V UP. (E)2" (E)2"●1/2" (E)EYEWASH IW 3/4" HOSE BIBB. FINAL CONNECTION TO WATER JET BY CU.FD-A 1 1/2" V DN (E)1 1/2"V(E)2 1/2" V UP & DN (E)V1 1/2" CUT & PATCH WALL TO CONNECT 3/4" IW TO 2" SAN. PROVIDE ACCESS PANEL. REFER TO DETAIL 1/P-100. 1/2" CA DN TO CA OUTLET. (E)1/2" PROVIDE CONDENSATE CONNECTION TO HVAC EQUIPMENT.●●1/2" PROVIDE WALL MOUNTED SPRING RETURN HOSE REEL WITH 8 FOOT OF 1/4" AIR HOSE, QUICK DISCONNECT AND THUMB LEVER AIR GUN TO MATCH WITH QUICK CONNECT, DESIGN BASIS, SPEEDAIRE RETURN HOSE REEL MODEL #2CUD6. REMOVE OR ADJUST SPRINKLER HEAD IN CEILING GRID TO ALLOW WORK TO BE PREFORMED. THEN REINSTALL OR RESET AS REQUIRED WITH CEILING INSTALLMENT. 1/2" TW DN TMV SET TO 50deg. DESIGN BASIS, WATTS LFLM490. (E)2" (E)2" (E)3/4" (E)3/4" (E)3/4" (E)3/4"(E)FP(E)3"(E)FPLAB 466 MAKER SPACE 466A 8 6.1 56 G F (E)CA(E)3/4" ●●● (E)2" SAN, (E)1/2" HW & (E)1/2" CW TO (E)SINK. (E)2" LV UP. (E)2" (E)2" (E)EYEWASH REMOVE CA OUTLET (E)1/2" REMOVE 1/2 CA DN TO OUTLET (E)2 1/2" V UP & DN (E)V (E)1 1/2" REMOVE PIPING AND PREP FOR NEW CONNECTION. (E)3/4" (E)3/4" (E)3/4" (E)3/4"(E)FP(E)FP(E)3"LAB 466 GENERAL NOTES: THESE NOTES ARE APPLICABLE TO THE FULL SET OF CONTRACT DOCUMENTS. EXISTING CONDITIONS ARE TAKEN FROM FIELD OBSERVATIONS AND PRIOR CONSTRUCTION DOCUMENTS WHEN AVAILABLE. THE LOCATIONS SHOWN MUST BE CONSIDERED APPROXIMATE. OTHER SUCH WORK MAY EXIST, HOWEVER, LOCATION AND SIZE ARE NOT PRESENTLY KNOWN. IT IS STRONGLY ENCOURAGED TO VISIT SITE PRIOR TO BID TO REVIEW EXISTING CONDITIONS AND CONFIRM SCOPE OF WORK. WHEN EXISTING CONSTRUCTION IS DAMAGED DURING WORK BY THIS CONTRACTOR, REPAIR AND/OR REPLACE WITH SIMILAR MATERIALS AS MUCH AS POSSIBLE, SUBJECT TO ARCHITECTS APPROVAL. DISPOSE OF ALL DEMOLITION AND/OR OTHER WASTE MATERIALS CAUSED BY WORK OF THIS CONTRACTOR. LEGALLY DISPOSE ALL MATERIALS TO A LOCATION OFF SITE. COORDINATE AND SCHEDULE WORK AND SHUTDOWNS WITH THE OWNER AND OTHER TRADES PRIOR TO DEMOLITION. ALL EXISTING PIPING TO REMAIN SHALL BE RECONNECTED TO ACTIVE SERVICE PIPING. ALL PIPING TO BE REMOVED, SHALL BE REMOVED BACK TO ACTIVE PIPING AND CAPPED. VALVE AND CAP ALL WATER PIPING. REMOVE ALL INACTIVE PIPING UNLESS NOTED. ALL PIPING TO BE REMOVED AND LOCATED WITHIN A WALL TO REMAIN MAY BE ABANDONED IN PLACE UNLESS NOTED. REMOVE PIPING BACK TO BEHIND THE FINISHED WALL SURFACE AND CAP. PATCH HOLES IN EXISTING CONSTRUCTION LEFT BY THE REMOVAL OF PIPING OR EQUIPMENT WITH MATERIALS TO MATCH EXISTING CONSTRUCTION. MAINTAIN FIRE/SMOKE RATING. DEMOLITION SHALL INCLUDE, BUT NOT BE LIMITED TO: PIPING, VALVES, FIXTURES, EQUIPMENT, HANGERS, SUPPORTS, AND INSULATION EXCEPT ASBESTOS. REMOVE EXISTING CONSTRUCTION IN THE WAY OF NEW WORK. PROTECT BUILDING AND FURNISHINGS FROM DAMAGE. WHERE NEW WORK IS TO BE INSTALLED ABOVE AN EXISTING CEILING, PROVIDE FOR THE REMOVAL OF THE CEILING. UPON COMPLETION OF WORK, REPAIR ALL DAMAGED CEILING SURFACES, REPLACE ALL DAMAGED TILES. SLEEVE AND SEAL ALL WALL AND FLOOR PENETRATIONS. PROVIDE FIRESTOPPING FOR ALL PENETRATIONS. MAINTAIN SERVICE CLEARANCES OF ALL EQUIPMENT. ADVISE OTHER TRADES OF THE REQUIRED SERVICE CLEARANCES. PROVIDE FOR THE DRAINING AND REFILLING OF PIPING SYSTEMS, INCLUDING AIR REMOVAL, RESETTING OF FLUSH VALVES, FLUSHING SYSTEMS OF DIRT AND SCALE CAUSED BY SHUTDOWNS AND STARTUPS. PROVIDE CLEANOUTS AT THE BASE OF ALL STORM, SANITARY AND WASTE STACKS. PITCH 4" AND LARGER LAB WASTE PIPING AT 1/8" PER FOOT UNLESS OTHERWISE NOTED. FOR LAB WASTE PIPING 3" AND SMALLER PITCH AT 1/4" PER FOOT UNLESS OTHERWISE NOTED. A. B. C. D. E. F. G. H. I. J. K. L. M. N. O. P. Q. 2D MINIMUM AIR GAP FUNNEL TRAP GAURD TRAP CLEANOUT 2" IW 2" LV CONDENSATE DRAIN CASKETED ACCESS PANEL CONNECT TO LW FROM SINK CONNECT TO LV FROM SINK DETAIL NOTES: DOMESTIC COLD WATER FLOW DIRECTION LABEL. PROVIDE 360 DEGREE WRAP OVERLAPPING BOTH ENDS OF THE PIPE FUNCTION LABEL AND MATCHING THE FLOW DIRECTION OF THE PIPE CONTENTS. PIPE FUNCTION LABEL A. B. C. D. E. F. PROVIDE A PIPE LABEL FOR EACH PIPE FUNCTION. PROVIDE AT LEAST ONE LABEL ON EACH PIPE FOR EVERY ROOM THE PIPE PASSES THROUGH. PROVIDE LABELS IN LARGE SPACES ON MAXIMUM 20' CENTERS FOR EVERY PIPE UNLESS OTHERWISE NOTED IN THE SPECIFICATIONS. LABELS TO BE LOCATED IN AN EASILY VISIBLE LOCATION AS THEY WOULD NORMALLY BE SEEN. IE. ON THE BOTTOM HALF OF PIPES IN THE AIR AND ON THE TOP HALF OR SIDES OF PIPES MOUNTED LOW. LABELS SHALL BE, COLOR CODED, PRE-PRINTED, SELF ADHESIVE VINYL. SEE SPECIFICATION FOR OTHER REQUIREMENTS AND LIST OF PIPE FUNCTIONS.NORTHThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions6/7/2021 1:55:12 PMC:\Users\sjgottlieb\Documents\210018_Upson Hall_Plumbing_Central_R20_sjgottlieb.rvt20625.03 THK General Notes, Symbols List, Details & Floor Plans - Pumbing GDD CMD P-100 100% Construction Documents Cornell University Upson Hall 466 Lab Renovation Ithaca, NY June 1, 2021 1/4" = 1'-0"3 Partial Third Floor Plan - Plumbing 1/4" = 1'-0"5 Partial Fourth Floor Plan - Plumbing 1/4" = 1'-0"4 Partial Fourth Floor Plan - Plumbing Demolition NOT TO SCALE1INDIRECT WASTE DETAIL NOT TO SCALE2PIPING IDENTIFICATION LABEL DETAIL DSD MBH THOUSAND BTU/HOUR (E)EXISTING DOUBLE LINE RECTANGULAR DUCT CONTINUED FPM FEET PER MINUTE AIR FLOW AFF ABOVE FINISHED FLOOR PIPE ANCHOR G.C. GENERAL CONTRACTOR PIPE GUIDE E.C. ELECTRICAL CONTRACTOR EXPANSION COMPENSATOR WITH GUIDES N.C.NORMALLY CLOSED PRE-FAB EXPANSION LOOP TEMPERATURE SENSOR STRAINER PRESSURE GAUGE THERMOMETER UNION 24x12DN UP AIR VENTV24x1214x8 6" BOOT TAP TT THERMOSTATIC TRAP 14"18"LATERAL FT FLOAT & THERMOSTATIC TRAP SUPPLY DIFFUSER, REGISTER OR GRILLE TD THERMODYNAMIC TRAP FLEXIBLE DUCTWORK BT BUCKET TRAP COMPRESSED AIRA DIRECTION OF FLOW BBD BOILER BLOW DOWN CONDENSER WATER SUPPLYCS CR CONDENSER WATER RETURN CWS CHILLED WATER SUPPLY CWR CHILLED WATER RETURN D DRAIN FUEL OIL FILLFOF FUEL OIL GAUGEFOG FOS FUEL OIL SUPPLY FOR FUEL OIL RETURN FOV FUEL OIL TANK VENT G GAS GLYCOL SUPPLYGS GLYCOL RETURNGR HPWS HEAT PUMP WATER SUPPLY HPWR HEAT PUMP WATER RETURN HWS HOT WATER SUPPLY HWR HOT WATER RETURN HG HOT GAS LPS LOW PRESSURE STEAM LPC LOW PRESSURE CONDENSATE MPS MEDIUM PRESSURE STEAM MPC MEDIUM PRESSURE CONDENSATE HPS HIGH PRESSURE STEAM HPC HIGH PRESSURE CONDENSATE PC PUMPED CONDENSATE RD REFRIGERANT DISCHARGE RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION VAC VACUUM CW DOMESTIC COLD WATER EXISTING WORK TO BE REMOVED DOUBLE LINE PIPE OR ROUND DUCT CONTINUED E PNEUMATIC THERMOSTAT NTS NOT TO SCALE (DBL) DOUBLE WALL LINED DUCT CFM CUBIC FEET PER MINUTE AD ACCESS DOOR P.C. PLUMBING CONTRACTOR N.O. NORMALLY OPEN DUCT SMOKE DETECTOR HUMIDISTAT ROUND DUCT - IN INCHES12" 24x12DN UP 14" CONICAL TEE18"VOLUME DAMPER CAP OR PLUG ELBOW DOWN ELBOW UP AAD AUTOMATIC AIR DAMPER FD FIRE DAMPER SD SMOKE DAMPER BDD BACK DRAFT DAMPER M MOTORIZED DAMPER BALL VALVE GATE VALVE CHECK VALVE BALANCING VALVE BUTTERFLY VALVE PRESSURE REDUCING VALVEPRV CONTROL VALVE PRESSURE/TEMPERATURE TEST PLUG (L) (2L) ACOUSTIC THERMAL LINING - 2" THICK M.C. MECHANICAL CONTRACTOR W/W WALL TO WALL G THERMOSTAT/SENSOR WITH GUARDG DUCT SECTION - SUPPLY DUCT SECTION - RETURN WIDTH A x DEPTH BA B R D 24x1214" 6" BOOT TAP BG BLAST GATE FIN TUBE RADIATION VALANCE A B C REGISTER, GRILLE OR DIFFUSER TAG A = TYPE B = NECK SIZE C = CFM B C D FIN TUBE RADIATION TAG FT-A = TYPE B = FIN TUBE LENGTH C = ENCLOSURE LENGTH D = GPM FT-A A B C D VALANCE TAG A = TYPE B = COIL SIZE C = COOLING GPM D = HEATING GPM POINT OF CONNECTION POINT OF DISCONNECTION BOTTOM TAP TRIPLE DUTY VALVETD GLOBE VALVE THREE WAY CONTROL VALVE SUCTION DIFFUSERSD DRAIN VALVE WITH HOSE CONNECTION, CAP AND CHAIN FC FLEX CONNECTOR - DUCTWORK FLEXIBLE CONNECTOR - PIPING AIR TERMINAL UNIT AND TAG (OPTION 1) A B C AIR TERMINAL UNIT TAG (OPTION 2) A = UNIT NO. B = MAXIMUM CFM C = MINIMUM CFM AxB FO DUCT SECTION - FLAT OVAL (FO) V VENT REDUCER S H S ACOUSTIC THERMAL LINING - 1-1/2" THICK EXHAUST GRILLE RETURN REGISTER SINGLE LINE PIPE CONTINUED TRANSITION SQUARE TO ROUND RISE IN DUCT - IN DIRECTION OF AIRFLOW DROP IN DUCT - IN DIRECTION OF AIRFLOW SUPPLY DUCT TURNING UP OR DOWN RETURN DUCT TURNING UP OR DOWN SUPPLY/RETURN RECTANGULAR MAIN RECTANGULAR BRANCH SUPPLY/RETURN RECTANGULAR MAIN ROUND BRANCH SUPPLY/RETURN ROUND MAIN ROUND BRANCH SUPPLY/RETURN ROUND MAIN ROUND BRANCH MITERED ELBOW WITH TURNING VANES DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL T RELIEF VALVE T HVAC SYMBOL LIST X X DRAWING KEYNOTE DEMOLITION KEYNOTE A B C RADIANT CEILING PANEL TAG A = TYPE B = LENGTH C = GPM CARBON DIOXIDE SENSORC CARBON MONOXIDE SENSORCO GAS SENSORG SYMBOL DESCRIPTION SYMBOL DESCRIPTION AVERAGING SENSOR SS START/STOP OC OPEN/CLOSE ED ENABLE/DISABLE T TEMPERATURE SENSOR (DUCT OR PIPE MOUNTED) H HUMIDITY SENSOR (DUCT MOUNTED) I P ELECTRICAL INTERFACE AUTOMATIC AIR DAMPER (PARALLEL BLADE) AUTOMATIC AIR DAMPER (OPPOSED BLADE) E ELECTRIC/ELECTRONIC CONTROL VALVE (3-WAY) E ES END SWITCH EA EXHAUST AIR MOISTURE SENSOR OCCUPANCY SENSOR FLOW METER SUPPLY FANSF BTU ENERGY METERBTU P DIFFERENTIAL STATIC PRESSURE SWITCH ALARM STATUS PROBE SENSOR RELAY FREEZE-STATFZ E ELECTRIC ACTUATOR CURRENT TRANSDUCER FLOW SENSOR AIR FLOW MEASURING STATION HARD WIRE INTERFACE S SOLENOID VALVE S M MANUAL SWITCH THERMOSTATIC EXPANSION VALVE CARBON DIOXIDE SENSOR (DUCT MOUNTED) CO 2 BINARY POINT ANALOG POINT THERMOWELL P DIFFERENTIAL STATIC PRESSURE TRANSMITTER ASD ADJUSTABLE SPEED DRIVE R134a REFRIGERANT R134a SENSOR (WALL MOUNTED) C C COOLING COIL BASE MOUNTED PUMP FILTER BANK RETURN AIR FANRF EF EXHAUST AIR FAN H C HEATING COIL SMOKE CONTROL FANSC HUMIDIFIER DISPERSION GRID E P ELECTRIC/PNEUMATIC SWITCH OR RELAY PE PNEUMATIC/ELECTRIC SWITCH OR RELAY F FLOW TRANSMITTER P PRESSURE TRANSMITTER ELECTRIC/PNEUMATIC TRANSDUCER IE ELECTRONIC/ELECTRIC TRANSDUCER PNEUMATIC CONTROL VALVE (3-WAY) PNEUMATIC CONTROL VALVE (2-WAY) ELECTRIC/ELECTRONIC CONTROL VALVE (2-WAY) PNEUMATIC ACTUATOR MAIN TEMPERATURE CONTROL AIR SOURCEA IN LINE PUMP HR C HEAT RECOVERY COIL AIR TERMINAL UNIT WITH FACTORY ATTENUATOR (OPTION 1) VAV-X-XX VAV-X-XX LAB AIR VALVE RADIANT CEILING PANEL FLOW SWITCH VARIABLE FREQUENCY DRIVE G B GAS BURNER P PRESSURE SWITCH HUMIDIFIERH A R S OS M FS F BUTTERFLY CONTROL DAMPER VFD OA OUTSIDE AIR RA RETURN AIR SA SUPPLY AIR CARBON MONOXIDE SENSOR (DUCT MOUNTED) CO F.L. FAIL LAST DEWPOINT SENSOR (DUCT MOUNTED) DP C CONDENSATE SENSOR STATIC PRESSURE SENSOR (DUCT MOUNTED) SP CT BI BINARY INPUT BO BINARY OUTPUT AI ANALOG INPUT AO ANALOG OUTPUT BV BINARY VALUE AV ANALOG VALUE HIGH LEVEL SWITCHHI LOW LOW LEVEL SWITCH VENTURI AIRFLOW CONTROL VALVE TRANSFORMER MOTOR STARTERMS ROTATION DETECTORRD SMOKE DETECTORSD MOD MODULATING ELECTRIC TO PNEUMATIC TRANSDUCER E P SPEED COMMANDSC AOM ADDRESSABLE OUTPUT MODULE (FIRE ALARM INTERFACE) COM NETWORK COMMUNICATION INTERFACE POINT SIGNAL OUT CURRENT SENSORCS SIGNAL OUT A SIGNAL IN AIR IN A SIGNAL IN ELECTRIC TO PNEUMATIC SWITCH LINE VOLTAGE THERMOSTAT T NITROGEN DIOXIDE SENSORN MOTOR S SPACE SENSOR WITH SETPOINT ADJUSTMENT SA S SPACE SENSOR WITH OCCUPANCY OVERRIDE S SPACE SENSOR WITH VISUAL DISPLAY S SPACE SENSOR WITH FAN ON/OFF SWITCH T ROOM TEMPERATURE SENSOR WITH SETPOINT ADJUSTMENT T T T ROOM TEMPERATURE SENSOR WITH OCCUPANCY OVERRIDE ROOM TEMPERATURE SENSOR WITH VISUAL DISPLAY ROOM TEMPERATURE SENSOR WITH FAN ON/OFF SWITCH BINARY INPUT (GENERAL)BI BO BINARY OUTPUT (GENERAL) ANALOG INPUT (GENERAL) ANALOG OUTPUT (GENERAL) AI AO LIQUID IMMERSION TEMPERATURE SENSOR T SINGLE POINT SENSOR M M OV D F SA OV D F F.O. FAIL OPEN RELATIVE HUMIDITY SENSORRH LOW LIMIT TEMPERATURE SWITCH FZ CONTROLS SCHEMATIC SYMBOL LIST GENERAL NOTES: A. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DISPOSE OF ALL DEMOLITION DEBRIS AND MATERIALS OFF SITE IN A PROPER LEGAL MANNER. B. ALL NEW PENETRATIONS THROUGH WALLS, FLOORS AND ROOFS SHALL BE PROVIDED FOR INSTALLATION OF MECHANICAL SYSTEMS INCLUDING, BUT NOT LIMITED TO, EQUIPMENT, DUCTWORK, PIPING, ETC. ALL PENETRATIONS THROUGH RATED WALLS AND FLOORS SHALL BE FIRE/SMOKE STOPPED. ALL PENETRATIONS THROUGH NON RATED WALLS SHALL BE SEALED WITH A NON-HARDENING SEALANT ON BOTH SIDES OF WALL PENETRATION TO REDUCE NOISE TRANSMISSION. C. THE DUCTWORK SIZES AND TYPES (ROUND, RECTANGULAR AND FLAT OVAL)WERE SELECTED FOR SPACE LIMITATION WITHIN THE RENOVATED AREA. IN ADDITION, THE DUCTWORK SIZES AND TYPES WERE CHOSEN TO ALLOW SPACE ABOVE THE CEILINGS FOR FUTURE DUCTWORK, PIPING AND/OR CONDUIT. IT IS NOT ACCEPTABLE FOR THE CONTRACTOR TO CHANGE THE SIZE OR TYPE OF DUCTWORK FOR BIDDING OR INSTALLATION UNLESS SPECIFICALLY APPROVED BY THE ENGINEER. D. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE ALL SHUTDOWNS OF AIR HANDLING, CHILLED WATER, HOT WATER, STEAM, ETC. SYSTEMS WITH CORNELL UNIVERSITY FACILITY PERSONNEL FOR TIE-IN CONNECTIONS. ALL SHUT DOWNS WILL OCCUR DURING NIGHTS OR WEEKENDS. THE CONTRACTOR SHALL ASSIST THE UNIVERSITY PERSONNEL IN SHUTTING DOWN, DRAINING, VENTING, ETC. OF SYSTEM TO FACILITATE THE INTENDED WORK. E. A MINIMUM OF 1'-6" SHALL BE PROVIDED IN FRONT OF CONTROL ACCESS ENCLOSURES AT ALL TERMINAL UNITS. NO PIPING OR CONDUIT SHALL BE DIRECTLY INSTALLED BELOW AIR TERMINAL UNIT ACCESS ENCLOSURES THAT WILL PROHIBIT ACCESS UP TO THE CONTROL ENCLOSURE. COORDINATE THESE REQUIREMENTS WITH ALL OTHER TRADES ON THE PROJECT. IF PROPER SERVICE ACCESS IS NOT MAINTAINED BECAUSE OF POOR COORDINATION, THE CONTRACTOR SHALL RELOCATE OBSTRUCTIONS AT NO ADDITIONAL COST TO THE OWNER. F. PROVIDE A VOLUME DAMPER AT EACH DIFFUSER AND GRILLE FOR PROPER BALANCING REGARDLESS IF SHOWN ON DRAWINGS. ALL VOLUME DAMPERS SHALL BE A MINIMUM OF 6'-0" FROM DIFFUSER OR GRILLE CONNECTION. IF FLEXIBLE DUCTWORK IS UTILIZED FOR FINAL CONNECTION AT GRILLES, THE CROSS SECTIONAL AREA OF THE FLEXIBLE DUCTWORK SHALL NOT BE LESS THAN THE CROSS SECTIONAL AREA OF THE GRILLE NECK. G. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE THE LOCATIONS OF ALL ROOM TEMPERATURE SENSORS WITH THE ARCHITECT/ENGINEER. THE CONTRACTOR SHALL SCHEDULE A WALK THROUGH WITH THE ARCHITECT/ENGINEER TO LOCATE SENSOR LOCATIONS PRIOR TO INSTALLATION. THE TEMPERATURE SENSORS SHALL BE INSTALLED IN ALIGNMENT WITH ELECTRICAL, FIRE, AND OTHER DEVICES WHEN LOCATED ON COMMON WALLS. H. DAMAGE TO EXISTING SYSTEMS (EQUIPMENT, PIPING, DUCTWORK, CONTROLS AND ACCESSORIES) SHOWN TO REMAIN AS A RESULT OF THE CONTRACTORS WORK IS THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR AND/OR REPLACE WITH SIMILAR OR LIKE MATERIALS AT NO ADDITIONAL COST TO THE OWNER. I. COORDINATE ALL SHUT DOWNS WITH OWNER PRIOR TO CONSTRUCTION. J. THE DEMOLITION DRAWINGS SHOW IN GENERAL MAJOR EQUIPMENT, PIPING AND DUCTWORK REMOVALS. THE INTENT IS NOT TO IDENTIFY ALL MISCELLANEOUS PIPING, PIPING ACCESSORIES, DUCTWORK, DUCTWORK ACCESSORIES, SUPPORTS, CONTROLS, CONTROL ACCESSORIES, CONTROL WIRING, CONDUIT, AND CONTROL PNEUMATIC TUBING AND ACCESSORIES TO BE DISCONNECTED AND REMOVED BUT IS THE REQUIREMENTS UNDER THIS CONTRACT. NO EQUIPMENT, PIPING OR DUCTWORK SHALL BE ABANDONED IN PLACE UNLESS OTHERWISE NOTED ON THE DRAWINGS. K. THE MOUNTING HEIGHT FOR ALL ROOM THERMOSTATS OR SENSORS SHALL BE 48 IN. TO TOP OF THE COVER. L. UNLESS SHOWN ON THE ARCHITECTURAL DRAWINGS, IT IS THE RESPONSIBILITY OF THIS CONTRACT TO PATCH WITH LIKE MATERIAL AND FINISH ALL EXISTING DUCTWORK OR PIPE PENETRATIONS THROUGH FLOORS AND WALLS AFTER DEMOLITION. M. EXISTING CONDITIONS ARE TAKEN FROM FIELD OBSERVATIONS AND PRIOR CONSTRUCTION DOCUMENTS AND ARE NOT GUARANTEED. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BID. NO ALLOWANCE WILL BE MADE FOR ADDITIONAL COSTS DUE TO CONTRACTORS FAILURE TO VERIFY EXISTING CONDITIONS AND DIMENSIONS. N. THE OWNER OCCUPIED AREAS INCLUDE SENSITIVE EQUIPMENT AND RESEARCH WHICH MUST NOT BE INTERRUPTED OR OTHERWISE DISTRUPTED WITHOUT PRIOR NOTICE AND APPROPRIATE PLANNING. These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions6/7/2021 1:44:40 PMC:\Users\sjgottlieb\Documents\210018_Upson Hall_HVAC_Central_R20_sjgottlieb.rvt20625.03 GDD General Notes and Symbols - HVAC GDD SJG M-000 100% Construction Documents Cornell University Upson Hall 466 Lab Renovation Ithaca, NY June 1, 2021 8 6.1 56 G F (E)10x6(E)12x8 (E)10x6 (E)14x6 (E)24x8 (E)24x8(E)36x8 (E)22x8 (E)2" (E)54x20 SA UP (E)44x20 EA UP(E)1 1/2" CWS/R (E)2" HWS/R (E)12x830x8 (E)14x8(E)12x81 1 (E)EAV (E)FAN COIL UNIT (E)FAN COIL UNIT(E)PROCESS CWR(E)PROCESS CWS(E)FUME HOOD (E)1 1/2" CWS/R (E)2" HWS/R (E)1 1/2" CWS/R (E)2" HWS/R (E)FAN COIL UNIT (E)2 1/2"PROCESS CWS/R UP/DN (E)ZONE REGISTER TERMINAL 2 2 (E)12"(E)12" S (E)VAV (E)VAV D (E)3/4" (E)3/4"(E)HWR(E)HWS(E)CWR(E)CWS(E)FAN COIL UNIT (E)10x8 (E)6" 1 1 (E)CWR(E)CWS LAB 466 OFFICE - STUDENTS 468 SOUTH CORRIDOR 40042 OFFICE - LECTURER 469 SM. CONFERENCE 465 (E)2" (E)18x18 RA UP (E)3/4" 8 6.1 56 G F 10"18x8 18x85" (E)24x8 (E)24x8(E)36x8 (E)22x8 (E)2" (E)2 1/2" PROCESS CWS/R UP/DN (E)54x20 SA UP (E)18x18 RA UP (E)44x20 EA UP 30x8 (E)14x810"10"10"12"(E)HWR(E)HWS7" (E)EAV S x128 A 220 x2210 A 550 (E)FAN COIL UNIT(E)PROCESS CWR(E)PROCESS CWS(E)FUME HOOD (E)1 1/2" CWS/R (E)2" HWS/R (E)FAN COIL UNIT (E)1 1/2" CWS/R (E)2" HWS/R (E)1 1/2" CWS/R (E)2" HWS/R (E)FAN COIL UNIT 3/4" CWSCWR (E)ZONE REGISTER TERMINAL (E)12" 3/4" x 225 18 1 6 x 225 18 1 6 x 220 18 1 6 (E)12" (E)FAN COIL UNIT (E)3/4" (E)CWS(E)CWR (E)CWS(E)2" D 18x8D (E)3/4" S (E)3/4"(E)CWR1 1 2 FCU-1 2 12" 7" R 6"SAV-2GEV-2GEV-1 SAV-1 18x812" MAKER SPACE 466A LAB 466 OFFICE - STUDENTS 468 SOUTH CORRIDOR 40042 OFFICE - LECTURER 469 SM. CONFERENCE 465 S S 3 3 4 4 10x6 8" 8" 5 6 6 7 7 NORTHThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions6/7/2021 1:44:43 PMC:\Users\sjgottlieb\Documents\210018_Upson Hall_HVAC_Central_R20_sjgottlieb.rvt20625.03 GDD Partial Fourth Floor Plans - HVAC GDD SJG M-100 100% Construction Documents Cornell University Upson Hall 466 Lab Renovation Ithaca, NY June 1, 2021 DEMOLITION NOTES 1 DISCONNECT AND REMOVE EXISTING DUCTWORK AND ACCESSORIES. 2 DISCONNECT AND REMOVE EXISTING AIR TERMINAL AND ASSOCIATED CONTROLS. 1/4" = 1'-0"1 Partial Fourth Floor Demolition Plan - HVAC 1/4" = 1'-0"2 Partial Fourth Floor Plan - HVAC DRAWING NOTES 1 TIE DUCTWORK INTO EXISTING. TRANSITION AS REQUIRED TO MAKE THE CONNECTION. 2 TIE PIPING INTO EXISTING. PROVIDE ALL PIPING MODIFICATIONS AS REQUIRED TO MAKE THE CONNECTION. 3 PROVIDE BREAK GLASS MANUAL SHUTOFF AT LOCATION SHOWN. SWITCH SHALL CONTROL/CLOSE THE AIR TERMINAL UNITS ASSOCIATED WITH THE SPACE. PROVIDE LABEL AT SWITCH WHICH READS "VENTILATION SYSTEM EMERGENCY SHUTOFF". 4 TAP FOR FUTURE LOW EXHAUST AS REQUIRED DUE TO THE FUTURE ADDITION OF OXYGEN DEPLETING GASSES IN THE LAB. 5 FAN COIL SHALL BE MOUNTED 9'-5" ABOVE FINISHED FLOOR. 6 CLEAN AND DEGREASE DUCTWORK WITHIN THE SPACE IN PREPARATION FOR PAINTING. 7 RECOMMISSION EXISTING FAN COIL UNIT. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. COOLING COIL AV SETPOINT N.C. SA C C H C HC FAN FAN HEATING COIL RA E E AO AOAI F.L. REFER TO PLANS OS BI SA D T AI SAI BACnet / ARCNET OR BACnet / MSTP: - AV: FLOW FEEDBACK (CFM) - AV: POSITION FEEDBACK (%) - AV: FLOW SETPOINT (CFM) COM ASD MOD AO SA BACnet / ARCNET OR BACnet / MSTP: - AV: FLOW FEEDBACK (CFM) - AV: POSITION FEEDBACK (%) - AV: FLOW SETPOINT (CFM) COM ASD MOD AO EA F CS M BI SS BO MS ZONE S MANUAL BREAK GLASS VENTILATION SHUTDOWN SWITCH. REFER TO PLANS. SEQUENCE OF OPERATION SYSTEM DESCRIPTION 4 PIPE FAN COIL UNIT GENERAL EXHAUST VAV (GEV) SUPPLY AIR VAV (SAV) GENERAL SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). ALL SETPOINTS SHALL BE ADJUSTABLE. THE BACS SHALL BE CAPABLE OF RETAINING ITS PROGRAMMING AND TIME SETTING DURING A LOSS OF POWER FOR AT LEAST TEN HOURS. LABORATORY AIR CHANGE RATES ARE BASED ON TOTAL EXHAUST AIR FLOW FROM THE SPACE. THE SPACE SHALL BE CONTROLLED TO AN AIR CHANGE RATE, THE BACS SHALL CALCULATE THE REQUIRED CFM USING THE GROSS VOLUME (AREA X CEILING HEIGHT). IF THE ZONE BECOMES OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED MODE FOR THE DURATION OF OCCUPANCY. WHEN THE SPACE BECOMES OCCUPIED AGAIN DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX BACK TO UNOCCUPIED MODE. SETPOINTS SPACE COOLING TEMPERATURE SETPOINTS: OCCUPIED: 750F UNOCCUPIED SETBACK:780F UNOCCUPIED:810F SPACE HEATING TEMPERATURE SETPOINTS: OCCUPIED: 700F UNOCCUPIED SETBACK:670F UNOCCUPIED:640F TOTAL EXHAUST AIR CHANGE RATE (ACPH): REFER TO LAB AIRFLOW SCHEDULES ACPH = TOTAL EXHAUST CFM X 60 / ROOM VOLUME TOTAL EXHAUST AIRFLOW RATE (CFM): REFER TO LAB AIRFLOW SCHEDULE SUPPLY AIRFLOW RATE (CFM): REFER TO LAB AIRFLOW SCHEDULE TYPICALLY = TOTAL EXHAUST AIRFLOW RATE + OFFSET GENERAL EXHAUST AIRFLOW RATE (CFM): REFER TO LAB AIRFLOW SCHEDULE SPACE AIR DIFFERENTIAL OFFSET (CFM): REFER TO LAB AIRFLOW SCHEDULE MINIMUM LABORATORY OCCUPANCY INDEX TIME:30 MINUTES ZONE OCCUPANCY SCHEDULE: COORDINATE WITH OWNER LABORATORY AIRFLOW CONTROL AIR VAV POSITIONS SHALL BE BASED ON MODE. UNDER NORMAL CONTROL, ROOM OCCUPANCY SHALL BE DETERMINED VIA ROOM OCCUPANCY SENSORS. WHEN THE ROOM IS OCCUPIED, THE GENERAL EXHAUST AIR VAV SHALL MODULATE AS NEEDED TO MAINTAIN THE OCCUPIED AIR CHANGE RATE. THE SUPPLY AIR VAV SHALL MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED AIRFLOW DIFFERENTIAL. WHEN THE ROOM IS UNOCCUPIED, THE GENERAL EXHAUST AIR VAV SHALL MODULATE AS NEEDED TO MAINTAIN THE UNOCCUPIED AIR CHANGE RATE. THE SUPPLY AIR VAV SHALL MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED AIRFLOW DIFFERENTIAL. REGARDLESS OF OCCUPANCY MODE, THE SUPPLY AND EXHAUST AIR VAVS SHALL COMMAND CLOSED UPON ACTIVATION OF THE MANUAL VENTILATION SHUT DOWN SWITCH. ZONE TEMPERATURE CONTROL SETPOINTS SHALL BE DETERMINED BASED ON A COMBINATION OF PROGRAMMED SCHEDULE AND SPACE OCCUPANCY SENSORS. OCCUPIED HEATING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD AND THE SPACE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING TEMPERATURE SETPOINT, THE FAN COIL UNIT SHALL START AND THE HEATING COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. WHEN THE SPACE TEMPERATURE IS AT SETPOINT,THE FAN COIL UNIT SHALL SHUT OFF AND THE HEATING COIL CONTROL VALVE SHALL CLOSE. OCCUPIED COOLING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD AND THE SPACE TEMPERATURE RISES ABOVE THE OCCUPIED COOLING TEMPERATURE SETPOINT, THE FAN COIL UNIT SHALL START, AND THE COOLING COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN SETPOINT. WHEN THE SPACE TEMPERATURE IS AT SETPOINT, THE FAN COIL UNIT SHALL SHUT OFF AND THE COOLING COIL CONTROL VALVE SHALL CLOSE. OCCUPIED SETBACK: IF THE SPACE BECOMES UNOCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, THE ABOVE OCCUPIED HEATING/COOLING SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE MAINTAINED AT THE OCCUPIED SETBACK TEMPERATURE SETPOINT. UNOCCUPIED HEATING: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD AND THE SPACE TEMPERATURE FALLS BELOW THE UNOCCUPIED HEATING TEMPERATURE SETPOINT, THE ABOVE OCCUPIED HEATING SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE MAINTAINED AT THE UNOCCUPIED SETBACK TEMPERATURE SETPOINT. UNOCCUPIED COOLING: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD AND THE SPACE TEMPERATURE RISES ABOVE THE UNOCCUPIED COOLING TEMPERATURE SETPOINT, THE ABOVE OCCUPIED SETBACK SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE MAINTAINED AT THE UNOCCUPIED COOLING TEMPERATURE SETPOINT. THE COOLING COIL CONTROL VALVE SHALL BE CLOSED WHENEVER THE HEATING COIL CONTROL VALVE IS OPEN TO PREVENT SIMULTANEOUS HEATING AND COOLING. THE COOLING COIL CONTROL VALVE SHALL BE CLOSED WHEN THE FAN COIL UNIT IS OFF. These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions6/7/2021 1:44:43 PMC:\Users\sjgottlieb\Documents\210018_Upson Hall_HVAC_Central_R20_sjgottlieb.rvt20625.03 GDD Control Schematics & System Summaries GDD SJG M-200 100% Construction Documents Cornell University Upson Hall 466 Lab Renovation Ithaca, NY June 1, 2021 NOT TO SCALE1LAB 466A WITH GENERAL EXHAUST AIR VAV, SUPPLY AIR VAV AND FAN COIL UNIT CONTROL SCHEMATIC AND SYSTEM SUMMARY 2.THE MAX / MIN POSITIONS ON THE VALVE WILL BE SET AT THE FACTORY TO THE FULL FANGE WITH ACTUAL AIRFLOW SET IN SOFTWARE. 1.THIS REPRESENTS A LABORATORY WHERE THE EXHAUST AIRFLOW IS BASED ON THE MINIMUM REQUIRED AIR CHANGE RATES ESTABLISHED FOR THE LABORATORY. NOTES 466A AC/HR LAB 220 10.0 58 1.6 220 6.0 GEV-2 6" 500 0 220 6.0 110 3.0 SAV-2 6" 500 0 110 0 -110 (SF) (FT) (CFM) (ACH) (CFM) (ACH) (CFM) (CFM) (CFM) (ACH) (CFM) (ACH) (CFM) (CFM) (CFM) (CFM) (CFM) MAX MIN MAX MIN AIRFLOW AIRFLOW (NOTE 4)(NOTE 2) OUTDOOR EXHAUST POINT SIZE RANGE POINT SIZE RANGE MODES (NOTE 1) AREA HEIGHT NYS NYS EXHAUST VAV VAV OCCUPIED UNOCCUPIED SUPPLY VAV VAV OCCUPIED UNOCCUPIED ALL ROOM NUMBER DESCRIPTION ROOM DIMENSIONS CODE MINIMUM VENTILATION EXHAUST AIR SUPPLY AIR XFER LAB AIRFLOW SCHEDULE SPACE OCCUPANCY, MINIMUM OCCUPANCY SETPOINT X X X X REFER TO PLANS SPACE OCCUPANCY X X X X REFER TO PLANS SPACE TEMPERATURE SETPOINT ADJUSTMENT X X REFER TO PLANS SPACE TEMPERATURE X X SPACE TEMPERATURE +/- 4 DEG F FROM SETPOINT X REFER TO PLANS SPACE TEMPERATURE SETPOINT, COOLING X X X SPACE TEMPERATURE SETPOINT, HEATING X X X SUPPLY VAV POSITION FEEDBACK (%)X X X COMMAND DOES NOT EQUAL FEEDBACK X BACnet MSTP NETWORK POINT SUPPLY VAV AIRFLOW SETPOINT (CFM)X X X BACnet MSTP NETWORK POINT SUPPLY VAV AIRFLOW FEEDBACK (CFM)X X X 10% FLOW DEVIATION FROM SETPOINT X BACnet MSTP NETWORK POINT SUPPLY VAV DAMPER POSITION COMMAND X X X GENERAL EXHAUST VAV POSITION FEEDBACK (%)X X X COMMAND DOES NOT EQUAL FEEDBACK X BACnet MSTP NETWORK POINT GENERAL EXHAUST VAV AIRFLOW SETPOINT (CFM)X X X BACnet MSTP NETWORK POINT GENERAL EXHAUST VAV AIRFLOW FEEDBACK (CFM)X X X 10% FLOW DEVIATION FROM SETPOINT X BACnet MSTP NETWORK POINT GENERAL EXHAUST VAV DAMPER POSITION COMMAND X X X FCU LEAVING AIR TEMPERATURE X X X LOW LIMIT X SINGLE POINT SENSOR FCU HEATING COIL CONTROL VALVE POSITION COMMAND X X X NORMALLY CLOSED FCU COOLING COIL CONTROL VALVE POSITION COMMAND X X X NORMALLY CLOSED FCU FAN STATUS X X X FAILURE X VIA CURRENT SENSOR FCU FAN MOTOR START/STOP X X X FLOW OFFSET ACTUAL (CFM)X X FLOW OFFSET SETPOINT (CFM)X X CEILING HEIGHT (SQ FT)X X ROOM AREA (SQ FT)X X LAB AIR CHANGE RATE (ACPH)X X X TOTAL EXHAUST SETPOINT (CFM)X X X TOTAL EXHAUST AIRFLOW (CFM)X X X CHILLED WATER LOAD SHED X (4)BINARY NETWORK INPUTS FROM EMCS STEAM LOAD SHED X (6)BINARY NETWORK INPUTS FROM EMCS BACS EMCS DESCRIPTIONBI BO AI AO AV BV SCH TREND EQUIPMENT HARDWARE POINTS SOFTWARE POINTS SHOWN ON GRAPHIC NOTES POINT SCHEDULE COOLING COIL AV SETPOINT HEATING COIL REFER TO PLANS OS BISA D T AI SAI BACnet / ARCNET OR BACnet / MSTP: - AV: FLOW FEEDBACK (CFM) - AV: POSITION FEEDBACK (%) - AV: FLOW SETPOINT (CFM) COM ASD MOD AO SA BACnet / ARCNET OR BACnet / MSTP: - AV: FLOW FEEDBACK (CFM) - AV: POSITION FEEDBACK (%) - AV: FLOW SETPOINT (CFM) COM ASD MOD AO EA F C C H C HC FANFAN E AO AOF.L. CS M BI SS AI T E AO AO F.L. SA FAN MOTOR WITH INTEGRAL ELECTRONIC SPEED CONTROL MS BO COOLING COIL HEATING COIL C C H C HC FANFANE AO AOF.L. CS M BI SS AI T E AO AOF.L. SA FAN MOTOR WITH INTEGRAL ELECTRONIC SPEED CONTROL MS BO INDICATES EXISTING ZONE S MANUAL BREAK GLASS VENTILATION SHUTDOWN SWITCH. REFER TO PLANS. SEQUENCE OF OPERATION SYSTEM DESCRIPTION EXISTING 4 PIPE FAN COIL UNITS GENERAL EXHAUST VAV (GEV) SUPPLY AIR VAV (SAV) GENERAL SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). ALL SETPOINTS SHALL BE ADJUSTABLE. THE BACS SHALL BE CAPABLE OF RETAINING ITS PROGRAMMING AND TIME SETTING DURING A LOSS OF POWER FOR AT LEAST TEN HOURS. LABORATORY AIR CHANGE RATES ARE BASED ON TOTAL EXHAUST AIR FLOW FROM THE SPACE. THE SPACE SHALL BE CONTROLLED TO AN AIR CHANGE RATE, THE BACS SHALL CALCULATE THE REQUIRED CFM USING THE GROSS VOLUME (AREA X CEILING HEIGHT). IF THE ZONE BECOMES OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED MODE FOR THE DURATION OF OCCUPANCY. WHEN THE SPACE BECOMES OCCUPIED AGAIN DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX BACK TO UNOCCUPIED MODE. SETPOINTS SPACE COOLING TEMPERATURE SETPOINTS: OCCUPIED: 750F UNOCCUPIED SETBACK:780F UNOCCUPIED:810F SPACE HEATING TEMPERATURE SETPOINTS: OCCUPIED: 700F UNOCCUPIED SETBACK:670F UNOCCUPIED:640F TOTAL EXHAUST AIR CHANGE RATE (ACPH): REFER TO LAB AIRFLOW SCHEDULES ACPH = TOTAL EXHAUST CFM X 60 / ROOM VOLUME TOTAL EXHAUST AIRFLOW RATE (CFM): REFER TO LAB AIRFLOW SCHEDULE SUPPLY AIRFLOW RATE (CFM): REFER TO LAB AIRFLOW SCHEDULE TYPICALLY = TOTAL EXHAUST AIRFLOW RATE + OFFSET GENERAL EXHAUST AIRFLOW RATE (CFM): REFER TO LAB AIRFLOW SCHEDULE SPACE AIR DIFFERENTIAL OFFSET (CFM): REFER TO LAB AIRFLOW SCHEDULE MINIMUM LABORATORY OCCUPANCY INDEX TIME:30 MINUTES ZONE OCCUPANCY SCHEDULE: COORDINATE WITH OWNER LABORATORY AIRFLOW CONTROL AIR VAV POSITIONS SHALL BE BASED ON MODE. UNDER NORMAL CONTROL, ROOM OCCUPANCY SHALL BE DETERMINED VIA ROOM OCCUPANCY SENSORS. WHEN THE ROOM IS OCCUPIED, THE GENERAL EXHAUST AIR VAV SHALL MODULATE AS NEEDED TO MAINTAIN THE OCCUPIED AIR CHANGE RATE. THE SUPPLY AIR VAV SHALL MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED AIRFLOW DIFFERENTIAL. WHEN THE ROOM IS UNOCCUPIED, THE GENERAL EXHAUST AIR VAV SHALL MODULATE AS NEEDED TO MAINTAIN THE UNOCCUPIED AIR CHANGE RATE. THE SUPPLY AIR VAV SHALL MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED AIRFLOW DIFFERENTIAL. REGARDLESS OF OCCUPANCY MODE, THE SUPPLY AND EXHAUST AIR VAVS SHALL COMMAND CLOSED UPON ACTIVATION OF THE MANUAL VENTILATION SHUT DOWN SWITCH. ZONE TEMPERATURE CONTROL SETPOINTS SHALL BE DETERMINED BASED ON A COMBINATION OF PROGRAMMED SCHEDULE AND SPACE OCCUPANCY SENSORS. OCCUPIED HEATING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD AND THE SPACE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING TEMPERATURE SETPOINT, THE FAN COIL UNIT SHALL START AND THE HEATING COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. WHEN THE SPACE TEMPERATURE IS AT SETPOINT,THE FAN COIL UNIT SHALL SHUT OFF AND THE HEATING COIL CONTROL VALVE SHALL CLOSE. OCCUPIED COOLING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD AND THE SPACE TEMPERATURE RISES ABOVE THE OCCUPIED COOLING TEMPERATURE SETPOINT, THE FAN COIL UNIT SHALL START, AND THE COOLING COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN SETPOINT. WHEN THE SPACE TEMPERATURE IS AT SETPOINT, THE FAN COIL UNIT SHALL SHUT OFF AND THE COOLING COIL CONTROL VALVE SHALL CLOSE. OCCUPIED SETBACK: IF THE SPACE BECOMES UNOCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, THE ABOVE OCCUPIED HEATING/COOLING SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE MAINTAINED AT THE OCCUPIED SETBACK TEMPERATURE SETPOINT. UNOCCUPIED HEATING: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD AND THE SPACE TEMPERATURE FALLS BELOW THE UNOCCUPIED HEATING TEMPERATURE SETPOINT, THE ABOVE OCCUPIED HEATING SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE MAINTAINED AT THE UNOCCUPIED SETBACK TEMPERATURE SETPOINT. UNOCCUPIED COOLING: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD AND THE SPACE TEMPERATURE RISES ABOVE THE UNOCCUPIED COOLING TEMPERATURE SETPOINT, THE ABOVE OCCUPIED SETBACK SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE MAINTAINED AT THE UNOCCUPIED COOLING TEMPERATURE SETPOINT. THE COOLING COIL CONTROL VALVE SHALL BE CLOSED WHENEVER THE HEATING COIL CONTROL VALVE IS OPEN TO PREVENT SIMULTANEOUS HEATING AND COOLING. THE COOLING COIL CONTROL VALVE SHALL BE CLOSED WHEN THE FAN COIL UNIT IS OFF. These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions6/7/2021 1:44:44 PMC:\Users\sjgottlieb\Documents\210018_Upson Hall_HVAC_Central_R20_sjgottlieb.rvt20625.03 GDD Control Schematics & System Summaries GDD SJG M-201 100% Construction Documents Cornell University Upson Hall 466 Lab Renovation Ithaca, NY June 1, 2021 NOT TO SCALE1LAB 466 WITH GENERAL EXHAUST AIR VAV, SUPPLY AIR VAV AND FAN COIL UNITS CONTROL SCHEMATIC AND SYSTEM SUMMARY 2.THE MAX / MIN POSITIONS ON THE VALVE WILL BE SET AT THE FACTORY TO THE FULL FANGE WITH ACTUAL AIRFLOW SET IN SOFTWARE. 1.THIS REPRESENTS A LABORATORY WHERE THE EXHAUST AIRFLOW IS BASED ON THE MINIMUM REQUIRED AIR CHANGE RATES ESTABLISHED FOR THE LABORATORY. NOTES 466 AC/HR LAB 550 10.0 219 2.4 550 6.0 GEV-1 7" 650 0 550 6.0 275 3.0 SAV-1 7" 650 0 475 200 -75 (SF) (FT) (CFM) (ACH) (CFM) (ACH) (CFM) (CFM) (CFM) (ACH) (CFM) (ACH) (CFM) (CFM) (CFM) (CFM) (CFM) MAX MIN MAX MIN AIRFLOW AIRFLOW (NOTE 2)(NOTE 2) OUTDOOR EXHAUST POINT SIZE RANGE POINT SIZE RANGE MODES (NOTE 1) AREA HEIGHT NYS NYS EXHAUST VAV VAV OCCUPIED UNOCCUPIED SUPPLY VAV VAV OCCUPIED UNOCCUPIED ALL ROOM NUMBER DESCRIPTION ROOM DIMENSIONS CODE MINIMUM VENTILATION EXHAUST AIR SUPPLY AIR XFER LAB AIRFLOW SCHEDULE SPACE OCCUPANCY, MINIMUM OCCUPANCY SETPOINT X X X X REFER TO PLANS SPACE OCCUPANCY X X X X REFER TO PLANS SUPPLY VAV POSITION FEEDBACK (%)X X X COMMAND DOES NOT EQUAL FEEDBACK X BACnet MSTP NETWORK POINT SUPPLY VAV AIRFLOW SETPOINT (CFM)X X X BACnet MSTP NETWORK POINT SUPPLY VAV AIRFLOW FEEDBACK (CFM)X X X 10% FLOW DEVIATION FROM SETPOINT X BACnet MSTP NETWORK POINT SUPPLY VAV DAMPER POSITION COMMAND X X X GENERAL EXHAUST VAV POSITION FEEDBACK (%)X X X COMMAND DOES NOT EQUAL FEEDBACK X BACnet MSTP NETWORK POINT GENERAL EXHAUST VAV AIRFLOW SETPOINT (CFM)X X X BACnet MSTP NETWORK POINT GENERAL EXHAUST VAV AIRFLOW FEEDBACK (CFM)X X X 10% FLOW DEVIATION FROM SETPOINT X BACnet MSTP NETWORK POINT GENERAL EXHAUST VAV DAMPER POSITION COMMAND X X X FLOW OFFSET ACTUAL (CFM)X X FLOW OFFSET SETPOINT (CFM)X X CEILING HEIGHT (SQ FT)X X ROOM AREA (SQ FT)X X LAB AIR CHANGE RATE (ACPH)X X X TOTAL EXHAUST SETPOINT (CFM)X X X TOTAL EXHAUST AIRFLOW (CFM)X X X CHILLED WATER LOAD SHED X (4)BINARY NETWORK INPUTS FROM EMCS STEAM LOAD SHED X (6)BINARY NETWORK INPUTS FROM EMCS BACS EMCS DESCRIPTIONBI BO AI AO AV BV SCH TREND EQUIPMENT HARDWARE POINTS SOFTWARE POINTS SHOWN ON GRAPHIC NOTES POINT SCHEDULE CWS CWR HWS HWR D P-TRAP DRAIN TO SANITARY ARRANGE FILTERS FOR REMOVAL TEST PLUG (TYP.) FAN COIL UNIT DETAIL NOTES: A.HANG UNIT FROM STRUCTURE AS HIGH AS POSSIBLE WITH STEEL ROD AND VIBRATION ISOLATORS. B.UNIT SHALL BE ACCESSIBLE FROM BELOW. MECHANICAL AND ELECTRICAL WORK SHALL NOT BE LOCATED BELOW UNIT. ARRANGEMENT SHALL PERMIT REMOVAL OF FAN COIL UNIT FOR MAJOR SERVICING. C.CONTROL PANEL SHALL BE ACCESSIBLE FOR SERVICING. D.DRAIN PIPING BY PLUMBING CONTRACTOR. STAINLESS STEEL BRAIDED HOSE (TYP.) These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions6/7/2021 1:44:44 PMC:\Users\sjgottlieb\Documents\210018_Upson Hall_HVAC_Central_R20_sjgottlieb.rvt20625.03 GDD Details & Schedules - HVAC GDD SJG M-300 100% Construction Documents Cornell University Upson Hall 466 Lab Renovation Ithaca, NY June 1, 2021 NOT TO SCALE1CEILING MOUNTED FAN COIL UNIT DETAIL - 4 PIPE A RETURN/EXHAUST ALUMINUM WHITE TITUS MODEL S8F - 1 SUPPLY ALUMINUM WHITE TITUS MODEL S300FL - TYPE APPLICATION MATERIAL FINISH MANUFACTURER & MODEL NO. REMARKS REGISTER GRILLE AND DIFFUSER SCHEDULE 2. PROVIDE WITH TIGHT SHUT-OFF. 1. INTEGRAL SOUND ATTENUATOR. REMARKS: GEV-2 466A 220 110 1 6 15 23 TITUS DESV 1,2 GEV-1 466 550 275 1 7 24 27 TITUS DESV 1,2 SAV-2 466A 110 0 1 5 - 22 TITUS DESV 1,2 SAV-1 466 475 200 1 7 22 25 TITUS DESV 1,2 (CFM) (CFM) (In. WC) FLOW FLOW MAX CFM (In.) AIR AIR PRESS AT SIZE AT 1" S.P. AT 1" S.P. UNIT NO. SERVICE MAX MIN MIN INLET INLET RAD N.C. DISCH N.C. MANUFACTURER & MODEL NO. REMARKS VAV - SINGLE DUCT - AIR TERMINAL UNIT SCHEDULE 1. SPECIFIED COOLING AND HEATING AND AIR FLOW CHARACTERISTICS ARE BASED UPON MEDIUM FAN SPEED. REMARKS: FCU-1 466A HORIZONTAL CABINET 230 - 4.73 0.72 5.45 75 63 56.2 54.9 0.80 8.75 47 62 4 10 9.93 65 103.8 1 0.69 130 109.9 1050 43 115 1 JOHNSON CONTROLS FHX-D03 1 (CFM) (In. WC) (MBH) (MBH) (MBH)(GPM) (Ft. HD) (DEG. F) (DEG. F)(DEG. F) (DEG. F) (GPM) (Ft. HD) (DEG. F) (DEG. F) FLOW STATIC SENSIBLE LATENT TOTAL DB WB DB WB FLOW P.D. TEMP. TEMP. (MBH) TEMP. TEMP. FLOW P.D. TEMP. TEMP. AIR EXT. CAPACITY EAT (DEG. F) LAT (DEG. F) WATER WATER ENT. WATER LVG. WATER ROWS FPI CAPACITY ENT. AIR LVG. AIR WATER WATER ENT. WATER LVG. WATER RPM WATTS VOLTS PHASE UNIT NO. LOCATION TYPE AIR SIDE COOLING COIL HEATING COIL FAN MOTOR MANUFACTURER & MODEL No. REMARKS FAN COIL UNIT SCHEDULE - CHILLED WATER/HOT WATER BASIC MATERIALS AND METHODS 3 HEAVY SOLID IS NEW, EXISTING ELECTRICAL WIRING, EQUIPMENT OR DEVICE, SOLID LIGHT IS EXISTING TO REMAIN , EXISTING ELECTRICAL WIRING, EQUIPMENT OR DEVICE, DASED LIGHT IS EXISTING TO BE REMOVED OR RELOCATED , REFERENCE TO DRAWING NOTE OS J TOGGLE SWITCH, VOLTAGE AS INDICATED ON FIXTURE SCHEDULE, SUBSCRIPTS INDICATE TYPE: 2 - TWO POLE SWITCH 3 - THREE WAY SWITCH 4 - FOUR WAY SWITCH M - MONENTARY CONTACT K - KEY OPERATED a,b,c - SWITCHING DESIGNATIONS NUMBER OF LETTERS EQUALS NO. OF GANGED SWITCHES V - VACANCY SENSOR VD - VACANCY SENSOR, DIMMER SWITCH VDS - VACANCY SENSOR, DUAL SWITCHED WP - WEATHERPROOF QUAD RECEPTACLE 20 AMP, 125 VOLT DUPLEX RECEPTACLE, 20 AMP, 125 VOLT SUBSCRIPTS INDICATE TYPE: G - GROUND FAULT INTERUPT OC - OVER COUNTER UC - UNDER THE COUNTER WP - WEATHER PROOF TP - TAMPER PROOF P - CEILING PROJECTOR, MOUNT IN PROJECTOR MOUNTING PLATE USB - INTEGRAL USB CHARGER H - MOUNT IN HORIZONTAL DIRECTION SPECIAL PURPOSE RECEPTACLE. PROVIDE PROPER VOLTAGE, CLASS, CURRENT RATING AND NEMA CONFIGURATION AS REQUIRED BY BRANCH CIRCUIT AND/OR MATCH CAP ON EQUIPMENT BEING FURNISHED BY OTHERS. PROVIDE CORD AND CAP. SUBSCRIPTS INDICATE TYPE: J CEILING MOUNTED OCCUPANCY SENSOR JUNCTION BOX 3a,b,c 3 REFERENCE TO DEMOLITION NOTE EXISTING TO REMAIN - INDICATES EXISTING ITEM SHALL REMAIN. MAINTAIN EXISTING ELECTRICAL CONNECTIONS UNLESS OTHERWISE NOTED. (E) EXISTING TO BE RELOCATED - INDICATES EXISTING ITEM SHALL BE RELOCATED. DISCONNECT AND REMOVE, REINSTALL AT NEW LOCATION AND RECONNECT ITEM AS REQUIRED. (ER) PUSH BUTTON COMMUNICATIONS EXISTING COMMUNICATIONS OUTLET TEL/DATA DROP: 4"x4"x2.50" BOX WITH A 1-GANG MUD RING & FACEPLATE WITH DUPLEX DESIGN. 1" CONDUIT EXTENDED TO NEAREST CABLE TRAY IN CORRIDOR ( UNLESS OTHERWISE NOTED) FOR DATA/VOICE. TERMINATE CONDUIT AT CABLE TRAY IN CORRIDOR WITH CONDUIT BUSHING. PULL (2) CAT 6 CABLE, TERMINATE AT PATCH PANEL IN BDF. W - SINGLE GANG BACK BOX WITH MUD RING AND 1" CONDUIT EXTENDED TO NEAREST CABLE TRAY IN CORRIDOR (UNLESS OTHERWISE NOTED) FOR DATA/VOICE. WALL MOUNT AT 46"AFF. PROVIDE (1) CAT 6 CABLE TO BDF. DDC - SINGLE GANG BOX WITH BLANK COVER PLATE. PROVIDE 3/4"C STUBBED TO ACCESSIBLE CEILING SPACE ABOVE. DDC ALARM WIRING BY DIV 23. C - CAMERA, COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL DRAWINGS. TV - COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL DRAWINGS. DSR DSS FSD FS TS FAAP FACP WAP H F F F SD S FIRE ALARM SMOKE DAMPER CONNECTION DUCT SMOKE DETECTOR, RETURN SIDE DUCT SMOKE DETECTOR, SUPPLY SIDE FIRE ALARM SHUT DOWN RELAY FLOW SWITCH CONNECTION TAMPER SWITCH CONNECTION FIRE ALARM ANNUNCIATION PANEL FIRE ALARM CONTROL PANEL REMOTE DUCT SMOKE DETECTOR TEST INDICATOR RATE-OF-RISE HEAT DETECTOR ALARM SIGNAL, STROBE, SHALL BE WHITE DEVICE ALARM SIGNAL, SPEAKER AND STROBE, SHALL BE WHITE DEVICE MANUAL PULL STATION SMOKE DETECTOR M D CB T CONTACTOR ENCLOSED CIRCUIT BREAKER COMBINATION FUSED DISCONNECT SWITCH AND MAGNETIC STARTER 208Y/120 VOLT PANELBOARD. TRANSFORMER COMPLETE ELECTRICAL CONNECTION TO EQUIPMENT A d A d CEILING MOUNTED EXIT LUMINAIRE WALL MOUNTED EXIT LUMINAIRE STRIP LUMINAIRE CEILING MOUNTED AREA-OF-RESCUE LUMINAIRE WALL MOUNTED AREA-OF-RESCUE LUMINAIRE CEILING MOUNTED LUMINARIE. UPPERCASE LETTERS INDICATE FIXTURE TYPE ON LUMINAIRE SCHEDULE, LOWER CASE LETTER INDICATE LIGHTING ZONE WALL MOUNTED LUMINARIE. UPPERCASE LETTERS INDICATE FIXTURE TYPE ON LUMINAIRE SCHEDULE, LOWER CASE LETTER INDICATE LIGHTING ZONE LUMINAIRE CONNECTED TO LIFE SAFETY EMERGENCY POWER WALL MOUNTED EMERGENCY LUMINAIRE WITH BATTERY PACK MOTOR CONNECTION. REFER TO ELECTRICAL EQUIPMENT AND CONTROL SCHEDULE FOR SIZE POWER DISTRIBUTION AND CONTROL 480Y/277 VOLT PANELBOARD. DISCONNECT SWITCH FUSED DISCONNECT SWITCH DISTRIBUTION PANELBOARD. MOTORIZED DAMPER CONNECTION LUMINAIRES TRACK LIGHTING DOUBLE HEAD POLE MOUNTED LUMINAIRE SINGLE HEAD POLE MOUNTED LUMINAIRE CEILING RECEPTACLE 4'-0" EXIT LIGHT SWITCH 2. MOUNTING HEIGHTS TO CENTER OF OUTLETS UNLESS OTHERWISE NOTED. IN MASONRY CONSTRUCTION THE ABOVE MOUNTING HEIGHTS SHALL BE USED FOR REFERENCE TO NEAREST BLOCK OR BRICK COURSING. THE ABOVE MOUNTING HEIGHTS SHALL BE ADHERED TO UNLESS SPECIFICALLY NOTED OR DETAILED OTHERWISE ON THE DRAWINGS. 1. DETAIL NOTES: 1'-6" DIVIDED SURFACE RACEWA Y HORN/LIGHT LENS ON TOP FINISHED FLOOR PULLSTATION COORDINATE EXACT MOUNTING HEIGHT WITH ARCHITECT. ENTIRE LENS SHALL BE MINIMUM 80" AFF AND NOT GREATER THAN 96" AFF. WHERE NOT PERMITTED BY CEILING HEIGHT DEVICE SHALL BE MOUNTED WITHIN 6" OF THE CEILING. 4'-0" EXIT SIGNS CENTERED ABOVE DOOR PR CARD READER, REFER TO DETAIL DOOR CONTACT COMBINATION POWER/COMMUNICATION SURFACE RACEWAY WITH DEVICES AS INDICATED. WIREMOLD G4000. RACEWAY SHALL BE MOUNTED "OVER COUNTER" UNLESS OTHERWISE NOTED. VS CEILING MOUNTED VACANCY SENSOR. WAP - WIRELESS ACCESS POINT WALL MOUNT AT 90"AFF 4"x4"x2.25" BOX WITH DOUBLE GANG PLASTER RING. 1" EMT CONDUIT EXTENDED TO NEAREST CABLE TRAY IN CORRIDOR (UNLESS OTHERWISE NOTED). PROVIDE TWO (2) CAT 6A CABLES. TERMINATE IN BDF AND 6-8" PIGTAIL WITHOUT FACEPLATE. All WAP ARE WALL MOUNTED. REFER TO ARROWS ON DRAWINGS FOR LOCATION. EM TYPICAL EMERGENCY PHONE OUTLET LOCATION. PROVIDE 4"x4" BACKBOX WITH A SINGLE GANG MUD RING AND (1) 3/4" CONDUIT TO ACCESSIBLE CEILING SPACE. PROVIDE (1) CAT 6 CABLE TO BDF. COORDINATE FINAL LOCATION WITH THE OWNER PRIOR TO INSTALLATION. RTS ENCLOSED CABLE TRAY SIZE PER QUANTITY OF CABLES AND 50% FUTURE CAPACITY AT A MINIMUM. CORD REEL: MAKE AND MODEL INFORMATION TBD LP-10,# HOME RUN TO PANELBOARD. LETTERS/ NUMBERS INDICATE PANEL. NUMBERS INDICATE CIRCUITS. NUMBER OF ARROWS EQUALS NUMBER OF CIRCUITS. CIRCUIT SHALL BE 2-#12, 1#12EG FROM 20A-1P CIRCUIT BREAKER, UNLESS NOTED OTHERWISE. BRANCH CIRCUIT WIRING SIZE AND NUMBER TO MATCH HOMERUN. REFER TO SPEC'S FOR RACEWAY TYPE. SOLID HALF ARROW(S) INDICATES 120 VOLT CIRCUIT TO SINGLE POLE CIRCUIT BREAKER(S), UNLESS NOTED OTHERWISE. SOLID FULL ARROW(S) INDICATES 208 VOLT CIRCUIT TO MULTI-POLE CIRCUIT BREAKER(S), UNLESS NOTED OTHERWISE. GFCI DUPLEX RECEPTACLE, 20 AMP, 125 VOLT G. H. I. WHEN EXISTING CONSTRUCTION, WHICH IS TO REMAIN, IS DAMAGED DURING THE COURSE OF DEMOLITION AS A RESULT OF THE CONTRACTOR'S WORK, IT SHALL BE REPAIRED AND/OR REPLACED WITH SIMILAR OR LIKE MATERIALS, AS MUCH AS POSSIBLE, SUBJECT TO THE OWNERS APPROVAL. THE CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND REPLACEMENT OF EXISTING CONSTRUCTION IN THE WAY OF NEW WORK. PROTECT BUILDING AND FURNISHINGS FROM DAMAGE. COORDINATE PHASING OF WORK WITH OWNER'S REPRESENTATIVE. COORDINATE ALL SHUTDOWNS WITH UNIVERSITY PRIOR TO DEMOLITION. ALL FIRE ALARM SHUTDOWNS SHALL BE SCHEDULED THROUGH CUSTOMER SERVICE WITH AT LEAST 24 HOURS NOTICE BEFORE WORK IS TO BE STARTED. EXISTING CONDITIONS ARE TAKEN FROM FIELD OBSERVATIONS AND PRIOR CONSTRUCTION DOCUMENTS WHEN AVAILABLE AND ARE NOT GARAUNTEED. PRIOR TO SUBMITTING BID, VISIT SITE AND IDENTIFY EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT THE DEMOLITION WORK. NO COMPENSATION WILL BE GRANTED FOR ADDITIONAL WORK CAUSED BY UNFAMILIARITY WITH SITE CONDITIONS THAT ARE VISIBLE OR READILY CONSTRUED BY EXPERIENCED OBSERVERS. THIS CONTRACTOR SHALL PARTICIPATE IN SURVEY OF THE EXISTING ELECTRICAL SYSTEMS. THE CONTRACTOR SHALL DISCONNECT AND CAP ALL SERVICE LINES TO BE DISCONNECTED FOR THOSE SERVICES WHICH NORMALLY ARE INCLUDED IN HIS FIELD OF WORK. PARTICULAR CARE SHALL BE TAKEN TO AVOID CREATING HAZARD OR CAUSING DISRUPTION IN ADJOINING AREAS. NOT ALL DEVICES TERMINATIONS, JUNCTION BOXES AND WIRING HAVE BEEN SHOWN. REFER TO PLUMBING CONTRACT DRAWINGS AND SPECIFICATIONS FOR EXACT QUANTITIES AND LOCATIONS OF ALL PLUMBING EQUIPMENT BEING ABANDONED OR REMOVED, WHICH WILL REQUIRE DE-ENERGIZATION, REMOVAL AND BLANK-OFF BY THE CONTRACTOR. EXISTING FIRE ALARM SYSTEM SHALL BE KEPT OPERATIONAL DURING THE CONSTRUCTION PERIOD THE BUILDING UNDER RENOVATION MAY BE DISCONNECTED FROM SERVICE DURING THE HOURS THE CONTRACTOR IS WORKING, AT THE DISCRETION OF THE FIRE DEPARTMENT AND THE OWNER'S REPRESENTATIVE, BUT MUST BE OKACED BACK ON LINE DURING OTHER PERIODS. APPROVAL TO BE IN WRITING. THE EXISTING ELECTRICAL EQUIPMENT AND DEVICES WITHIN DEMOLITION AREA SHALL BE DEMOLISHED ALONG WITH ALL FEEDERS AND CONDUITS BACK TO POINT OF SOURCE UNLESS OTHERWISE NOTED. ALL ITEMS SHOWN ON THE DEMOLITION DRAWINGS SHALL BE DISCONNECTED AND REMOVED UNLESS NOTED OTHERWISE. WALLBOXES, BACKBOXES AND CONDUIT SHALL BE REUSED AS DETERMINED BY CONTRACTOR. ALL UNUSED CONDUITS SHALL BE REMOVED. DISCONNECT AND MAKE SAFE ANY EQUIPMENT TO BE REMOVED BY OTHERS. COORDINATE REMOVAL OF EQUIPMENT WITH OTHER TRADES PRIOR TO DEMOLITION. MAINTAIN AND RESTORE, IF INTERRUPTED BY REMOVALS OR IN PATH OF NEW CONSTRUCTION, ALL CIRCUITS, CONDUITS AND FEEDERS PASSING THROUGH AND SERVING UNDISTURBED AREAS (SHOWN OR NOT SHOWN). ALL EXISTING CONDUITS STUBBED THROUGH FLOOR SERVING ITEMS TO BE REMOVED AND NOT SHOWN OR REQUIRED TO BE REUSED, SHALL BE CUT OFF FLUSH WITH SLAB LEVEL WITH CONCRETE. IN ANY AREA REQUIRING THE PERFORMANCE OF ANY TRADE'S WORK WORK, THIS CONTRACTOR SHALL CAREFULLY REMOVE AND STORE ANY OR ALL ELECTRICAL ITEMS IN PATH OF WORK, REINSTALLING AND RECONNECTING SAME AS REQUIRED, IN ACCORDANCE WITH THE PLANS AND/OR AS DIRECTED AFTER COMPLETION OF OTHER TRADE'S WORK IN THAT AREA. DISCONNECT, MAKE SAFE AND REMOVE ALL TEMPORARY AND ABANDONED WIRE WITHIN THE SPACE. BRANCH CIRCUIT WIRING TO DEVICES IN AREAS OF DEMOLITION SHALL BE DISCONNECTED, MADE SAFE AND REMOVED COMPLETELY BACK TO THE PANELBOARD. THE CONTRATOR SHALL NOT ABANDON BRANCH CIRCUIT WIRING TO ANY AREAS WICH ARE TO REMAIN BUT ARE AFFECTED BY THE DEMOLITION OR NEW CONSTRUCTION. DISCONNECT AND REMOVE PANEL, FEEDERS AND BRANCH CIRCUITS BACK TO POINT OF SOURCE PRIOR TO THE START OF DEMOLITION, CONTRACTOR SHALL FIELD VERIFY ALL BRANCH CIRCUITS AND MAINTAIN THOSE CIRCUITS THAT EXTEND OUTSIDE OF THE SCOPE OF WORK. AFTER RENOVATING EXISTING ELECTRICAL WORK, THE CONTRACTOR SHALL INSURE THAT ALL REMAINING AND NEW EQUIPMENT WILL OPERATE PROPERLY. PROVIDE TEMPORARY HEAT DETECTORS IN AREAS WHERE SPRINKLERS ARE REMOVED FROM SERVICE DURING CONSTRUCTION. COORDINATE WITH FIRE PROTECTION CONTRACTOR. REFER TO MACHANICAL CONTRACT DRAWINGS AND SPECIFICATIONS FOR EXACT QUANTITIES AND LOCATIONS OF ALL MECHANICAL EQUIPMENT BEING ABANDONED OR REMOVED, WHICH WILL REQUIRE DE-ENERGIZATION, REMOVAL AND BLANK-OFF BY THE CONTRACTOR. GENERAL DEMOLITION NOTES:(APPLY TO ALL DRAWINGS): A. B. C. D. E. F. G. H. I. SLEEVE AND SEAL ALL WALL AND FLOOR PENETRATIONS. PROVIDE FIRESTOPPING FOR ALL FIRE-RATED PENETRATIONS. UTILIZE REMOVABLE FIRESTOPPING MATERIAL AT CABLE TRAY PENETRATIONS. PROVIDE ACOUSTICAL SEALANT FOR ALL NON RATED PENETRATIONS. ALL FIRE RATINGS SHALL BE MAINTAINED. MAINTAIN SERVICE CLEARANCES OF ALL EQUIPMENT. COORDINATE EXACT LOCATION OF ALL CONDUIT ROUTES, EQUIPMENT AND DEVICES WITH EXISTING CONDITIONS PRIOR TO CONSTRUCTION. MINIMUM CONDUIT SIZE SHALL BE 3/4" FOR POWER CIRCUITS UOI. PROVIDE NYLON PULLSTRING IN ALL EMPTY CONDUITS. FIRE ALARM SIGNALING APPLIANCES SHALL BE MOUNTED SUCH THAT THE ENTIRE LENS IS NOT LESS THAN 80 INCHES AND NOT GREATER THAN 96 INCHES ABOVE THE FINISHED FLOOR. CIRCUITING TO DEVICES/EQUIPMENT SHALL BE 2-#12AWG & 1-#12EG (MULTIPLE HOME RUNS IN SAME CONDUIT MAY SHARE SAME EQUIPMENT GROUND) FOR EACH 20 AMPERE CIRCUIT UNLESS OTHERWISE NOTED. ALL CIRCUITS SHALL HAVE SEPARATE NEUTRALS (CIRCUITS SHALL NOT SHARE NEUTRALS). PROVIDE CONDUIT/WIRING (CIRCUITING) AND REQUIRED EQUIPMENT CONNECTIONS TO ALL DEVICES/EQUIPMENT. CONNECT TO CIRCUIT(S) AS INDICATED. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE REFERENCE STANDARD EDITION OF NFPA CODES, AS CITED BY THE FIRE CODE OF NEW YORK STATE, BUILDING CODE OF NEW YORK STATE AND CORNELL UNIVERSITY DESIGN STANDARDS. ALL CONDUITS AND SUPPORTS SHALL BE AS TIGHT TO DECK AS POSSIBLE. PROVIDE PULLBOX FOR EVERY 180 DEGREE OF BENDS FOR TEL/DATA AND 360 DEGREES OF BENDS FOR POWER CONDUITS. ALL ELECTRICAL DEVICES (RECEPTACLES, SWITCHES, FIRE ALARM, ETC.) SHALL BE ALIGNED HORIZONTALLY AND VERTICALLY. CONTRACTOR TO SCHEDULE AND COORDINATE PROJJECT WALKTHROUGH WITH ARCHITECT AND ENGINEER PRIOR TO COMMENCEMENT OF ANY DEVICE ROUGH-IN FOR FINALIZATION OF ALIGNMENTS. REFER TO EAV SERIES DRAWINGS FOR ADDITIONAL ELECTRICAL WORK. ALL EXISTING DEVICES CIRCUITED TO PANELS BEING RENAMED SHALL BE PROVIDED WITH UPDATED LABELS. PROVIDE ALL PATHWAYS AND BACK BOXES AS CALLED FOR ON AV DRAWINGS PROVIDED BY ANOTHER CONSULTANT. COORDINATE IT SERVICE CHANGES OR DISRUPTIONS IN SERVICE WITH CIT OPERATIONS AT 255-5500. ALL RECEPTACLES WITHIN 6' OF SINK EDGE SHALL BE GFCI TYPE. GENERAL NOTES:(APPLY TO ALL DRAWINGS): A. B. C. D. E. F. J. K. L. M. N. J. K. L. M. N. FCU FAN COIL UNIT FIRE ALARM CONTROL PANEL FIRE ALARM TERMINAL CABINET CONT.CONTACTOR F.A.T.C. F.A.C.P. ELECTRIC WATER COOLER DISTRIBUTION PANEL GROUND FAULT CIRCUIT INTERRUPTER GENERAL CONTRACTOR ELECTRICAL CONTRACTOR HEATING, VENTILATING AND AIR CONDITIONING F.A.FIRE ALARM H.V.A.C. G.C. E.C. BSMT.BASEMENT CLG. EA. CONTR. GEN. CEILING EACH GENERATOR A.AMPERE DN. EXIST. AUTO. DOWN EXISTING AUTOMATIC DP EMERG. ELEC. G.F.C.I. ELECTRIC EMERGENCY HORSEPOWER GALVANIZED RIGID STEEL GND.GROUND GRS. ABBREV. ABBREVIATIONS C BKR. HP. CAMERA BREAKER DESCRIPTION FZ (3)FIRE ZONE (3) ABOVE FINISHED FLOORA.F.F. EM.EMERGENCY CONTRACTOR A.F.G.ABOVE FINISHED GRADE EWC MOUNTED UNDER COUNTER HEIGHT TV TELEVISION WEATHERPROOF REFRIGERATOR SPECIFICATION MOUNTED OVER COUNTER HEIGHT PLUMBING CONTRACTOR TELEPHONE BACKBOARD TELEPHONE TERMINAL CABINET T.B.B. MICRO T.T.C. MICROWAVE P.C. REFRIG. TYP.TYPICAL SPEC. P. SP.SPACE POLE NL NIGHT LIGHT V.VOLT SW. SWITCH MAIN CIRCUIT BREAKER MAIN LUG ONLY P = POLE A = AMPERE UNDERWRITER'S LABORATORY LTG. U.L. 4 W. KW. LIGHTING KILOWATT WIRE M.L.O. 3P.15A. PH. M.C.B. PHASE PNL.PANEL PV POWER VENTILATOR WP OC UC UV WG VP EF EHP CUH UNIT VENTILATOR WIRE GUARD FRACTIONAL HORSEPOWER EXHAUST FAN CABINET UNIT HEATER VANDAL PROOF POLYCARBONATE GUARD ABBREVIATIONS ABBREV. DESCRIPTION WAP WIRELESS ACCESS POINT O. UH UNIT HEATER P. O. P. Q. AAD AUTOMATIC AIR DAMPER Q. CR DC These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions6/7/2021 1:42:51 PMC:\Users\crspall\Documents\210018_Upson Hall_Electrical_Central_R20_crspall.rvt20625.03 WRS Symbols List & General Notes - Electrical GDD CRS E-000 100% Construction Documents Cornell University Upson Hall 466 Lab Renovation Ithaca, NY June 1, 2021 F WAP S F S WAP S M F CR CR CR MDC J 8 6.1 56 G F (E) LPP-4-9(E) LPP-4-10(E)(E) (ER) (E) (E) (E) (ER) (E) (E) (E) LAB 466 (E)(E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) 2 8 6.1 56 G F (E) (E) (E) (E) (E) FCU-1 LPP-4-9(E) LPP-4-10(E) 1 (E) (ER) 2 (ER) (E) (E) DOOR OPERATOR 13 172121 21 19 23 25,27,29 31 31 31 33 2 35,37 39,41 GFI 4,6,8 3 12 14 4 4 20 1616161616 18 18 1818 5 6 LAB 466 MAKER SPACE 466A 26 VAV 20 28 28 28 (E)(E)(E) (E) (E) (E) (E) (E)(E) (E) (E) (E) 7 DEMOLITION NOTES: 1. ALL TO BE DEMOLISHED DEVICES SHALL BE DEMOLISHED AND REMOVED BACK TO SOURCE PANEL. ALL EXISTING BREAKERS SHALL BE MADE SPARE IF NO LONGER IN USE. 2. REMOVE SECTION OF EXISTING RACEWAY. REFER TO ARCHITECT PLANS FOR EXACT LENGTH OF REMOVAL. GENERAL NOTES: A. ELECTRICAL CONTRACTOR SHALL CONNECT THE NEW FIRE ALARM DEVICES INTO THE EXISTING FIRE ALARM SYSTEM. B. ALL TEL/DATA CABLING SHALL ROUTE BACK TO IT ROOM 428 VIA CABLE TRAY IN CORRIDOR 40042. ROOM IS ADJACENT TO ELECTRIC ROOM 40062 AND IS APPROXIMATELY 120' NORTH OF RENOVATION AREA. C. ALL RACEWAY SHALL BE MOUNTED AT 39" ON CENTER AFF. D. ALL EXISTING CEILING DEVICES IN THE CORRIDOR SHALL BE FIELD COORDINATED FOR TEMPORARY REMOVAL AND REINSTALLATION AS REQUIRED FOR MECHANICAL WORK. E. ALL ELECTRICAL DEVICES AND EQUIPMENT SHALL BE CIRCUITED TO PANEL LPP-4-10, CIRCUIT NUMBER AS INDICATED ON PLANS. UNLESS OTHERWISE NOTED. DRAWNG NOTES: 1. PUSH BUTTON KILL SWITCH SHALL SHUT DOWN MILL/DRILL, BANDSAW, LASER CUTTER AND DRILL PRESS. SHALL BE A 30A (8) POLE BRANCH CIRCUIT CONTACTOR. 2. PANELS ARE LOCATED ON NORTH WALL APPROXIMATELY 20 FEET FROM LAB DOUBLE DOOR ENTRANCE. 3. DC POWER SUPPLY SHALL HAVE 100A DISCONNECT SUPPLIED WITH IT. BREAKER AND WIRE SHALL BE SIZED FOR 70A -SHALL BE (1) SET OF #4AWG & (1)#8EGC IN 1" CONDUIT. 4. TIE RECEPTACLES INTO EXISTING CIRCUIT #9 FROM PANEL LPP-4-10. 5. CONTRACTOR SHALL PROVIDE A PLUG FOR EQUIPMENT AND INSTALL IT TO CORD PROVIDED WITH EQUIPMENT FOR USER PLUG-IN. 6. CONTRACTOR SHALL INSTALL AN INTERLOCK SAFETY SWITCH BETWEEN FILTRATION BOX AND LASER CUTTER FOR PROPER OPERATION OF EQUIPMENT. SEE DRAWING E-202 DETAIL #3 FOR FURTHER INFORMATION. 7. SPECIAL RECEPTACLE SHALL BE LOCATED OVER COUNTER, NOT IN EXISTING RACEWAY. REFER TO ARCHITECT PLANS FOR FINAL LOCATION.NORTHThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions6/7/2021 1:42:53 PMC:\Users\crspall\Documents\210018_Upson Hall_Electrical_Central_R20_crspall.rvt20625.03 WRS Partial Fourth Floor Plan - Power & Special Systems GDD CRS E-100 100% Construction Documents Cornell University Upson Hall 466 Lab Renovation Ithaca, NY June 1, 2021 1/4" = 1'-0"1 Partial Fourth Floor Demolition Plan - Power & Special Systems 1/4" = 1'-0"2 Partial Fourth Floor Plan - Power & Special Systems OS OS a,bD DS OS OS D DDS OS 8 6.1 56 G F 2 (E) (E) (E) (E) (E) (E) LAB 466 8 6.1 56 G F (E) X1 (E) (E) (E) (E) (E) (E) L1L1 L1 L1 L1 1 EM L1 L1 L1 LAB 466 MAKER SPACE 466A 2 DEMOLITION NOTES: 1. NOT USED. 2. ALL EXISTING LIGHTS THAT ARE TO BE REMOVED SHALL BE TURNED OVER TO OWNER. GENERAL NOTES: A. SALVAGED LIGHTING CIRCUIT SHALL BE REWORKED AND EXTENDED AS REQUIRED FOR CONNECTION TO NEW LIGHT FIXTURES. B. NEW EXIT SIGN SHALL BE TIED INTO EXISTING EMERGENCY EXIT SIGN CIRCUIT. C. ALL EM LIGHT FIXTURES SHALL HAVE UL924 RELAY INSTALLED TO CONTROLTHE LIFE SAFETY LIGHTING. D. ALL LIGHT FIXTURE AIRCRAFT CABLE WIRING SHALL BE FIELD COORDINATED TO CORRECT LENGTH. ELECTRICAL COORDINATOR SHALL FIELD COORDINATE WITH ALL OTHER CONTRACTORS FOR COORDINATION OF LIGHT MOUNTING. E. ALL EXISTING CEILING DEVICES IN THE CORRIDOR SHALL BE FIELD COORDINATED FOR TEMPORARY REMOVAL AND REINSTALLATION AS REQUIRED FOR MECHANICAL WORK. F. ALL OCCUPANCY SENSORS SHALL INCLUDE AUXILLARY CONTACTS FOR HVAC EQUIPMENT. DRAWNG NOTES: 1. TIE (4) 4' FIXTURES INSIDE DETAIL OUTLINE TO NEW DAYLIGHT SENSOR. 2. OWNER FURNISHED/CONTRACTOR INSTALLED UNDERSHELF TASK LIGHTING. CONTRACTOR SHALL INSTALL FIXTURE TO UNDERSHELF PER ARCHITECT DRAWINGS. FIXTURES SHALL PLUG INTO RACEWAY AND BE OPERATED VIA TOGGLE SWITCH BUILT INTO FIXTURE.NORTHThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions6/7/2021 1:42:54 PMC:\Users\crspall\Documents\210018_Upson Hall_Electrical_Central_R20_crspall.rvt20625.03 WRS Partial Fourth Floor Plan - Lighting GDD CRS E-101 100% Construction Documents Cornell University Upson Hall 466 Lab Renovation Ithaca, NY June 1, 2021 1/4" = 1'-0"1 Partial Fourth Floor Demolition Plan - Lighting 1/4" = 1'-0"2 Partial Fourth Floor Plan - Lighting GENERAL NOTES: 1. FIXTURE FINISH COLOR SHALL BE COORDINATED WITH ARCHITECT AND OWNER. REFERENCE NOTES: 1. REFER TO ARCHITECT LAB EQUIPMENT SCHEDULE FOR ALL PLUG TYPES. 2. PROVIDE EM SHUTDOWN SYSTEM FOR ALL TECH EQUIPMENT AND OUTLETS. 3. PROVIDE USB CONNECTION BETWEEN WORKSTATION AND CNC MACHINE. These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions6/7/2021 1:42:55 PMC:\Users\crspall\Documents\210018_Upson Hall_Electrical_Central_R20_crspall.rvt20625.03 WRS Schedules - Electrical GDD CRS E-200 100% Construction Documents Cornell University Upson Hall 466 Lab Renovation Ithaca, NY June 1, 2021 FCU-1 FAN COIL UNIT 466 LAB 0.2 1 120 1.7 LPP-4-10 20/1 2#12 1#12 3/4"C 2#12 1#12 3/4"C X AU 30A NF AU FCU-1 PHASE GROUND CONDUIT PHASE GROUND CONDUIT SWITCH AMPS FUSE SIZE LOC.WEATHER PROOF REF. NOTES ITEM ID NAME ROOM LOCATION HP KW PHASE SYSTEM VOLTS MCA or SYSTEM AMPS PANEL or CONTROL CENTER CIRCUIT BREAKER or "FU" FOR FUSE POWER WIRING FROM PANEL TO CONTROL UNIT POWER WIRING FROM CONTROL UNIT TO EQUIPMENT NEMA SIZE STARTERNEMA TYPEMANUAL MOTOR STARTERMANUAL MOTOR STARTERWITH RELAYMAGNETIC STARTERCOMBINATION MAGNETICSTARTERCOMBINATION REDUCEDVOLTAGE STARTERCOMBINATION STARTERMP/FUSE (F) SIZEADJUSTABLE SPEEDDRIVEADJUSTABLE SPEEDDRIVEWITH BYPASSADJUSTABLE SPEEDDRIVEWITH REDUNDANT ASDPACKAGED CONTROLUNIT FURNISHED BYOTHERSDUPLEX PUMPCONTROLLER BY OTHERSFIRE ALARM FANSHUTDOWN REQUIREDSUPPLY DUCT SMOKEDETECTOR W/ REMOTETEST STATIONRETURN DUCT SMOKEDETECTOR W/ REMOTETEST STATIONEXHAUST DUCT SMOKEDETECTOR W/ REMOTETEST STATIONTHERMOSTATCONNECTIONAQUASTAT CONNECTIONMOTORIZED DAMPERCONNECTIONSTART/STOPPUSHBUTTONSHAND/OFF/AUTOSELECTOR SWITCHCONTROL DEVICELOCATIONSAFETY SWITCH ITEM ID EQUIPMENT POWER SOURCE, PROTECTION & WIRING CONTROL DEVICES AS SHOWN ON THE PLANS BY ITEM DESIGNATION G. "IU" INDICATES INTEGRAL WITH UNIT. F. "NF" INDICATES NON-FUSED. E. "AU" INDICATES CONTROL DEVICES IS LOCATED AT THE UNIT. D. PROVIDE OVERLOADS, SIZE AS REQUIRED, BY THE DIVISION 22/23 CONTRACTOR. C. ALL DEVICES SHALL BE SURFACE MOUNTED UNLESS OTHERWISE NOTED. B. ITEM NUMBER INDICATES EQUIPMENT NUMBER A. ALL DEVICES PROVIDED BY THE DIVISION 26 CONTRACTOR. ELECTRIC EQUIPMENT AND CONTROL SCHEDULE GENERAL NOTES: Notes: Total Est. Demand:16 A Total Conn.:16 A Total Est. Demand:5940 VA Receptacle 5440 VA 100.00% 5440 VA Total Conn. Load:5940 VA Power 500 VA 100.00% 500 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Legend: Total Amps:17 A 20 A 14 A Total Load:1940 VA 2340 VA 1660 VA 41 ---- -- 0 VA 0 VA 1 20 A Spare 42 39 WATER JET 30 A 2 180 VA 0 VA 1 20 A Spare 40 37 ---- -- 0 VA 0 VA 1 20 A Spare 38 35 LASER CUTTER 20 A 2 400 VA 0 VA 1 20 A Spare 36 33 CORD REEL 20 A 1 180 VA 0 VA 1 20 A Spare 34 31 Receptacle 20 A 1 540 VA 0 VA 1 20 A Spare 32 29 ---- -- 0 VA 0 VA 1 20 A Spare 30 27 ---- -- 0 VA 540 VA 1 20 A Receptacle 28 25 BANDSAW 20 A 3 0 VA 500 VA 1 20 A Power 26 23 DRILL PRESS 30 A 1 180 VA 0 VA 1 20 A EXISTING 24 21 Receptacle 20 A 1 540 VA 0 VA 1 20 A EXISTNG 22 19 3D PRINTER 20 A 1 180 VA 360 VA 1 20 A Receptacle 20 17 3D PRINTER 20 A 1 180 VA 720 VA 1 20 A Receptacle 18 15 EXISTING 20 A 1 0 VA 900 VA 1 20 A Receptacle 16 13 MILL DRILL 20 A 1 180 VA 180 VA 1 20 A CORD REEL 14 11 EXISTING 20 A 1 0 VA 180 VA 1 20 A CORD REEL 12 9 EXISTING 20 A 1 0 VA 0 VA 1 20 A EXISTING 10 7 EXISTING 20 A 1 0 VA 0 VA -- -- --8 5 EXISTING 20 A 1 0 VA 0 VA -- -- --6 3 EXISTING 20 A 1 0 VA 0 VA 3 70 A DC POWER SUPPLY 4 1 EXISTING 20 A 1 0 VA 0 VA 1 20 A DOOR OPERATOR 2 CKT Circuit Description Trip Poles A B C A B C Poles Trip Circuit Description CKT Notes: Enclosure:Type 1 MCB Rating:100 A Mounting:Surface Wires:4 Mains Rating:100 A Supply From:Phases:3 Mains Type: Location:Volts:120/208 Wye A.I.C. Rating: Branch Panel: LPP-4-10(E) X1 LED EXIT SIGN REFER TO PLANS FOR MOUNTING BARRON: NXFR SERIES LED 120/277V CEILING - 1 L1 1x4 SUSPENDED FIXTURE FLUXWERX: VU1-B-XX LED 120/277V SUSPENDED 25 1 TYPE DESCRIPTION MFR. & CATALOG No. LAMP VOLTAGE/BALLAST MOUNTING UNIT WATTS REFERENCE NOTES LUMINAIRE SCHEDULE J FILTRATION BOX 1 1.1 12 120 1 LPP-4-10 20/1 2#12 #12 3/4" 1,2 H 10 kW DC BENCH POWER SUPPLY 1 48 208 3 LPP-4-10 70/3 3#4 #8 1" 1 G2 CNC WATER JET WORKSTATION... 1 2 120 1 LPP-4-10 20/1 2#12 #12 3/4" 1 G1 CNC WATER JET ABRASION CUTTER... 1 22 240 1 LPP-4-10 30/2 3#10 #10 3/4" 1,2,3 F LASER CUTTER (EPILOG HELIX LASER) TBD 1 208 1 LPP-4-10 20/2 2#12 #12 3/4" 1,2 E BAND SAW 1 1 5 230 3 LPP-4-10 20/3 2#12 #12 3/4" 1,2 D DRILL PRESS 1 .75 13 120 1 LPP-4-10 30/1 2#10 #12 3/4" 1,2 C 3D PRINTER (SMALL PRUSA) - TBD 1 .120 1 120 1 LPP-4-10 20/1 2#12 #12 3/4" 1 B 3D PRINTER (LARGE, MARKFORGE MARK 2)... 1 2 120 1 LPP-4-10 20/1 2#12 #12 3/4" 1 A MILL DRILL 1 8 120 1 LPP-4-10 20/1 2#12 #12 3/4" 1,2 PHASE GND CONDUIT HP KW AMPS TECHNOLOGY EQUIPMENT DESIGNATION DESCRIPTION QTY. (5) LOAD VOLTAGE PHASE PANEL CIRCUIT BREAKER BRANCH CIRCUIT WIRING NOTES TECHNOLOGY EQUIPMENT ELECTRICAL CONNECTION... BRANCH BREAKER NUMBER TYPICAL BLNL5-17 GENERAL DETAIL NOTES: PANEL NAME HL-T106-17 HL-T106-17 RECEPTACLE (EMERGENCY CIRCUIT RECEPTACLE SHALL BE "RED") B. PROVIDE GREEN GROUND WIRE IN ALL RECEPTACLE CIRCUITS. CONNECT TO GROUND BUS IN PANEL. DO NOT INSTALL RECEPTACLES, COMPUTER OR TELEPHONE OUTLETS BACK TO BACK. INSTALL IN ADJACENT STUD CAVITIES, TO REDUCE SOUND TRANSMISSION. A. 1/2" CONDUIT TO ABOVE LAY-IN CEILING WITH BUSHED END GROUNDING PIN ON TOP OR TO LEFT OF OUTLET ON HORIZONTALLY MOUNTED RECEPTACLES 1/2" CONDUIT TO ABOVE LAY- IN CEILING WITH BUSHED END TAPE LABEL, VERIFY COLOR WITH OWNER, ADHERE TO COVERPLATE. (ACTUAL CIRCUIT INFORMATION SHALL BE AS INSTALLED AND NOT NECESSARILY THE SAME CIRCUIT NUMBER AS SHOWN ON THE PLANS.)REDBLU.BLK.RED (LINE) WHT. BLK. RED BLK. BLU. LOAD CEILING OCCUPANCY SENSOR 120/277V GRY.LOW VOLTAGE MOMENTARY ON/OFF SWITCH RED ADDITIONAL SWITCHES AS INDICATED ON THE PLAN VIEWS DETAIL NOTES: 0-10VDC CONTROL WIRING PROVDIE JUMPER WIRE TO ACCOMMODATE ROCKER SWITCH STYLE MOMENTARY ON/OFF SWITCH. PROVIDE ADDITIONAL OCCUPANCY SENSORS AS INDICATED ON THE PLANS VIEWS. ADDITIONAL POWER/RELAY PACKS SHALL BE PROVIDED TO ACCOMMODATE THE SENSOR QUANTITIES AS REQUIRED BY THE MANUFACTURER. 0-10VDC DIMMER SUITABLE FOR USE WITH THE INDIATED LUMINIARE TYPE POWER SUPPLY. PROVIDE WHERE INDICATED ON THE PLANS TO PROVIDE DIMMING CAPABILITIES. RED (LOAD) CONTROL OUTPUT COMMON +24 VDC WHITE / NEUTRAL POWER/RELAY PACKNEUTRAL LINE D 3 1 1 2 2 1 3 EQUIPMENT: "INSERT DESIGNATION" POWER SOURCE: "INSERT SOURCE" TYPE SUPPLY: INSERT-NORMAL, OR CRITICAL OPERATION POWER, OR OPTIONAL STANDBY, OR LEGALLY REQUIRED, OR LIFE SAFETY EMERGENCY AS APPLICABLE" VOLTAGE: "INSERT APPLICABLE VOLTAGE-208/120V OR 480/277V, ETC." CONDUCTOR COLOR CODING: PHASE A - "BLACK OR BROWN" PHASE B - "RED OR ORANGE" PHASE C - "BLUE OR YELLOW" NEUTRAL - "WHITE OR GRAY" GROUND - GREEN AVAILABLE SHORT CIRCUIT CURRENT: "INSERT AMPS RMS" PROVIDE CUSTOM NAMEPLATE AS INDICATED FOR ALL PANELBOARDS, MCC'S, SWITCHBOARDS, SWITCHGEAR, TRANSFER SWITCHES, GENERATORS ETC. NAMEPLATE SHALL BE ENGRAVED (WHITE LETTERING, BLACK BACKGROUND) AND ATTACHED TO THE EQUIPMENT WITH SCREWS. LETTERING SHALL BE 1/4" HIGH WITH SPACE BETWEEN LINES 1/8" MINIMUM. MINIMUM SHALL BE 8"H x 8"W. PROVIDE SAMPLE NAMEPLATE FOR REVIEW. THE AVAILABLE SHORT CIRCUIT SHOULD BE PROVIDED AT THE SERVICE ENTRANCE. 2. 1. DETAIL NOTES: 3. 4. LINE NEUTRAL BLK LOAD WHITE / NEUTRAL RED (LINE) POWER/RELAY PACKWHT. BLK. OFF SWITCH RED (LOAD)BLUBLKREDCONTROL OUTPUTBLU COMMON +24VDCRED BLU CONTROL OUTPUT COMMONBLK +24VDC CEILING SENSOR CEILING SENSOR RED PROVIDE A COMPLETE DIGITAL LIGHTING ROOM CONTROLLER WITH FEATURES INDICATED ON THE DRAWINGS AND IN THE SPECIFICATIONS WITHIN THE INDICATED SPACES. PROVIDE ALL REQUIRED COMPONENTS FOR A COMPLETE SYSTEM. ALL SYSTEM WIRING SHALL BE AS REQUIRED BY THE SYSTEM MANUFACTURER. THE WIRING DIAGRAM IS GENERIC. ALL NECESSARY COMPONENTS MAY NOT BE SHOWN. REFER TO SPECIFIC ROOM PLANS AND ZONING INDICATED FOR ALL SYSTEM REQUIREMENTS AND COMPONENTS. REFER TO SPECFICATIONS FOR FURTHER REQUIREMENTS. GENERAL NOTES: A. B. C. REFER TO PLANS FOR QUANTITY. SOME SPACES SHALL HAVE THE PHOTOCELL INTEGRAL TO THE FIXTURE. REFER TO THE FLOOR PLANS AND SPECIFICATIONS FOR MORE INFORMATION. DETAIL NOTES: 1 1 1 WHT. BLK.120/277V BLUE BLUE GRAY VIOLET GREEN 0-10V DIMMING LED DRIVER IN FIXTURE 0-10V DIMMING LED DRIVER IN FIXTURE CAT. 5e UTP CAT. 5e UTP CAT. 5e UTP CAT. 5e UTP CEILING OCCUPANCY/ VACANCY SENSOR CEILING OCCUPANCY/ VACANCY SENSOR DIMMING CONTROLLER CEILING PHOTO SENSOR NEUTRAL LIGHTING ROOM 1 DIGITAL WALL SWITCH AND/OR DIMMER AR AUXILARY RELAY FOR HVAC CONTACT TO EMS 2 2 1 20/1 NEUTRAL E EE C TECH EQUIPMENT ELECTRICALLY HELD CONTACTOR WITH 2 WIRE CONTROL MODULE MOUNTED IN SOUNDPROOF NEMA 1 ENCLOSURE. PANEL 30/1 30/1 30/1 30/1 WIRING INDICATED ON THE RISER DIAGRAM IS DIAGRAMMATIC ONLY AND IS NOT INTENDED TO INDICATE ROUTING OR QUANTITIES OF WIRES REQUIRED. PROVIDE WIRING FOR A COMPLETE SYSTEM AS REQUIRED BY SYSTEM MANUFACTURER. ALL DEVICES MAY NOT BE INDICATED ON RISER DIAGRAM: REFER TO FLOOR PLANS FOR QUANTITIES AND LOCATIONS OF DEVICES. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. GENERAL RISER NOTES: A. B. M M M M These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions6/7/2021 1:42:56 PMC:\Users\crspall\Documents\210018_Upson Hall_Electrical_Central_R20_crspall.rvt20625.03 WRS Details - Electrical GDD CRS E-201 100% Construction Documents Cornell University Upson Hall 466 Lab Renovation Ithaca, NY June 1, 2021 1/8" = 1'-0"1 TYPICAL RECEPTACLE IDENTIFICATION REQUIREMENTS NTS2CEILING MOUNTED OCCUPANCY SENSOR (DIMMING) NTS3EQUIPMENT NAMEPLATE DETAIL NTS4CEILING MOUNTED OCCUPANCY SENSOR (MULTIPLE SENSORS) 1/8" = 1'-0"5 TYPICAL LIGHTING CONTROL DIAGRAM NOT TO SCALE6EMERGENCY SHUTDOWN DETAIL ACCESS CONTROLLER TO ACCESS CONTROLLER ELECTRIC STRIKE POWER SUPPLY WITH BATTERY BACKUP ACCESS CONTROLLER POWER SUPPLY EM 120V. MOTION SENSOR POWER TRANSFER HINDGE MAGNETIC DOOR CONTACTS (CONCEALED) CRASH BAR DOOR ELECTRIC STRIKE PUSH BUTTON (OPPOSITE SIDE OF DOOR) BELDEN NO. 9873 CABLE TO SECURITY PANEL LOCAL ACCESS CONTROL ALARM TO FIRE ALARM SYSTEM (RELEASE ON ANY FIRE ALARM) ACCESS CONTROLLER AC-5000 TO ACCESS CONTROLLER OR BUILDING CONTROLLER 4-PAIR, 24 AWG CAT. 5 CABLE TO PANEL ___ DS DS ACPDPS CORD REEL #12/3 CORD WIRE MESH CORD GRIP, HUBBELL 074010 TYPE UTILITY BOX AND COVER WITH TWISTLOCK L5-20 RECEPTACLE TWISTLOCK PLUG TO MATCH RECEPTACLE PROVIDE CHANNEL OR ANGLE SUPPORT STEEL MOUNTED TO BUILDING STRUCTURE BOX WITH 20A DUPLEX RECEPTACLE LOCATED 6'-6" FROM FLOOR HARD MOUNTED. REFER TO OWNER/ARCH FOR FINAL REEL LOCATION. 3/4" CONDUIT NEMA 208V RECEPTACLE SHALL MATCH USER EQUIPMENT REQUIREMENTS INCOMING LASER POWER CURRENT SENSOR CT IN J-BOX LASER CUTTER LASER CUTTER POWER CORD DRY CONTACT INPUT TIME DELAY RELAY DOM RIBD01BDC INCOMING RIB RELAY CONTROL POWER BOFA AD BASE 2 ORACLE LASER FILTER LASER FILTER POWER CORD INCOMING FILTER POWER R CT LASER CUTTER REFERENCE NOTES: A. ELECTRICAL CONTRACTOR WITH SUPPORT FROM LAB STAFF, SHALL MEASURE TYPICAL LASER CUTTER AMP DRAW: a. EXPECTED "STANDBY" STATE OF LASER CUTTER BETWEEN 0.01AMP TO 0.5AMP. THIS SHALL BE THE "LASER OFF" LOW LIMIT OF ADJUSTABLE CT CURRENT SENSOR. b. EXPECTED "OPERATING" STATE OF LASER BETWEEN 0.5AMP TO 5AMP. THIS SHALL BE THE "LASER ON" HIGH LIMIT OF ADJUSTABLE CT CURRENT SENSOR. B. ELECTRICAL CONTRACTOR SHALL WIRE THE ADJUSTABLE CT CURRENT SENSOR OUTPUT DRY- CONTACT CLOSURE TO THE BOFA FILTER UNIT "START STOP" OPTIONAL ON/OFF INPUT "RED AND WHITE" WIRES. C. ELECTRICAL CONTRACTOR, WITH SUPPORT FROM LAB STAFF, SHALL CHECK ALL MODES OF LASER CUTTER OPERATION TO ENSURE BOFA UNIT FUNCTIONS CONTINUALLY AS THE LASER CUTTER IS IN OPERATION MODE. D. ELECTRICAL CONTRACTOR SHALL INSTALL A "DELAY ON MAKE" CONTROL RELAY UNIT TO PREVENT THE BOFA FILTER FROM CYCLING ON/OFF DURING NORMAL LASER CUTTER OPERATION. PROVIDE 10-MINUTE "DELAY ON MAKE" (DOM) RIBD01BDC DELAY RELAY WHEN A SIGNAL IS SENT TO START THE BOFA FILTER FROM THE ADJUSTABLE CURRENT SENSOR. THIS WILL ALSO ENSURE THE BOFA FILTER RUNS FOR AN EXTRA TEN MINUTES AFTER THE LASER CUTTER FINISHED WORKING. TIME DELAY TO BE COORDINATED WITH OWNER. E. ALL COMPONENTS ARE MOUNTED TO THE BACK OF THE BOFA FILTER. These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions6/7/2021 1:42:56 PMC:\Users\crspall\Documents\210018_Upson Hall_Electrical_Central_R20_crspall.rvt20625.03 WRS DETAILS II - ELECTRICAL GDD CRS E-202 100% Construction Documents Cornell University Upson Hall 466 Lab Renovation Ithaca, NY June 1, 2021 NTS 1 TYPICAL DOOR ACCESS CONTROL SYSTEM NTS 2 CORD REEL DETAIL 1/8" = 1'-0" 3 LASER CUTTER/BOFA DIAGRAM PROJECT: Upson Hall 466 Lab Renovation Date: June 30, 2021 RFI Form RFI/Page/ Response Dwg./Spec./Rep.Section/Design Team Index Number Paragraph/Topic RFI Response 1 23 82 19 Part 2, Article 2.2 Specification Section 23 82 19 Fan Coil Units indicates that the basis of design is Trane. The Fan Coil Unit Schedule on plan sheet M-300 indicates Johnson Control FHX-DO3. Please clarify which is correct. See Addendum No. 1, Item 2. Johnson Controls is basis of design. 2 23 09 23 Part 2 Drawing Note 3 on plan sheet M-100 notes provide a break glass manual shutoff. Please provide brand/manuf. and model #. See Addendum No. 1, Item 1. 3 Bid Proposal Certification Form, Page BF-3 Page BF-3 of the Bid Proposal Certification From indicates that Bidder Project Qualifications are to be submitted with our bid on e-Builder. No criteria is stated. Is there a specific format to be used? No project qualifications are required. 4 26 05 01 Please provide a spec/part number for the new cord reels (detail 2, Sheet E202). See Addendum No. 1, Item 3. Cord reel shall be equal to Hubbell HBL45123R20.