HomeMy WebLinkAbout[001] G1.069'-4 1/2"2'-6 1/2"41'-9 1/4"39'-9 7/8"1'-11 3/8"71'-11"G1.0COVER SHEETSLEEP NUMBER
3000 SQ. FT. LEASED AREA VIF
0
SYMBOLS
X0
REFERENCE
0'0" AFF
NORTH
ROOM DESIGNATION
DOOR NUMBER
FINISH TYPE
WALL TYPE
KEYNOTE
FIXTURE,EQUIMENT
SPECIFICATION DIVISION
LEASE LINE
EXISTING WALL CONSTRUCTION
NEW WALL
NEW DOOR
EXISTING DOOR
NORTH ARROW
DATUM/ELEVATION
GRID LINE
ELEVATION REFERENCE
SECTION REFERENCE
DETAIL REFERENCE
REVISION
PARTIAL WALL CONSTRUCTION
00000
LBL
100
SALES AREA
0
0
A
WT
0
A0.0
0
A0.0
0
A0.0
ABBREVIATIONS
ACOUSTICAL CEILING TILE
ABOVE DATUM
ABOVE DATUM ZERO (0.00")
ABOVE FINISHED FLOOR
ALTERNATE
ALUMINUM
APPROXIMATELY
BOARD
BOTTOM OF
CEILING
COLUMN
CONCRETE
CONTINUOUS, CONTINUE
CONCRETE MASONRY UNIT
DEPTH (DIMENSION)
DETAIL
DIAMETER
DIMENSION
DOOR
DRAWING
ELEVATION
ELECTRIC(AL)
EQUAL/EQUIVALENT
EQUIPMENT
EXISTING
EXTERIOR
FINISH(ED)
FLOOR
FACE OF FINISH
FIBERGLASS REINF PANEL
FIRE RESISTANT TREATED
GAUGE
GYPSUM BOARD
HANDICAPPED
HARDWARE
HOLLOW METAL
HORIZONTAL
HOUR
HEIGHT
HEATING/VENTILATION
AIR CONDITIONING
INTERIOR
JOINT
LAMINATE
LIGHT
LANDLORD
MAXIMUM
MECHANICAL
MINIMUM
MISCELLANEOUS
MOISTURE RESISTANT
MOUNTED
METAL
NOT IN CONTRACT
NUMBER
NOT TO SCALE
OVER ALL
ON CENTER(S)
OUTSIDE DIAMETER/DIMENSION
OPPOSITE
PARTIAL
PARTICLE BOARD
PLASTIC LAMINATE
PROJECT MANUAL
PLYWOOD
RADIUS
REQUIRED
REFER(ENCE)
REVERSE
SCHEDULE
SHEET
SIMILAR
SPECIFICATION(S)
SQUARE
STAINLESS STEEL
STANDARD
STEEL
SYMMETRICAL
TO BE DETERMINED
THICK
TOP OF
TYPICAL
UNDERWRITER LABORATORIES
UNLESS NOTED OTHERWISE
VINYL COMPOSITION TILE
VERTICAL
VERIFY IN FIELD
WIDTH (DIMENSION)
WITH
WOOD
WELDED WIRE FABRIC
ACT
AD
ADZ
AFF
ALT
ALUM
APPROX
BD
B/O
CLG
COL
CONC
CONT
CMU
D
DTL
DIA
DIM
DR
DWG
EL
ELEC
EQ
EQUIP
EX
EXT
FIN
FLR
FOF
FRP
FRT
GA
GYP BD
HC
HDWR
HM
HORZ
HR
HT/H
HVAC
INT
JT
LAM
LT
LL
MAX
MECH
MIN
MISC
MR
MTD
MTL
NIC
NO
NTS
OA
OC
OD
OPP
PART
PARTBD
PLAT
PM
PLYWD
R
REQD
REF
REV
SCHD
SHT
SIM
SPEC
SQ
SS
STD
STL
SYM
TBD
THK
T/O
TYP
UL
UNO
VCT
VERT
VIF
W
W/
WD
WWF
1.WORK DELINEATED IN THESE DRAWINGS AND SPECIFICATIONS SHALL CONFORM TO CODES, STANDARDS
AND REGULATIONS THAT GOVERN IN THE JURISDICTION IN WHICH THE WORK IS PERFORMED.
2.REQUIREMENTS AND REGULATIONS PERTAINING TO THE HANDICAPPED MUST BE INCORPORATED IN THE
WORK EVEN THOUGH THEY MAY NOT BE LISTED INDIVIDUALLY AND SEPARATELY IN EITHER THE
DRAWINGS OR SPECIFICATIONS.
3.IN LOCATIONS WHERE CONCRETE SLAB IS RECENTLY POURED (WITHIN 12 MONTHS PRIOR TO START OF
CONSTRUCTION) GC IS RESPONSIBLE FOR PERFORMING A MOISTURE TEST OF SLAB TO INSURE PROPER
ADHESION OF CARPET MASTIC TO SLAB. NOTIFY SLEEP NUMBER PROJECT MANAGER IF HIGH MOISTURE
CONTENT IS A PROBLEM.
4.COMPARE FIELD CONDITIONS WITH ARCHITECTURAL AND ENGINEERING DRAWINGS. ANY DISCREPANCIES
SHALL BE DIRECTED TO THE ARCHITECT FOR CLARIFICATION PRIOR TO FABRICATION AND/OR
CONSTRUCTION. SUBMIT ALL NECESSARY SHOP DRAWINGS PRIOR TO FABRICATION FOR APPROVAL BY
ARCHITECT. NO INFORMATION OR DETAILS ON THESE SHEETS MAY BE USED WITHOUT THE PERMISSION
OF SLEEP NUMBER CORPORATION OR THE ARCHITECT.
5.DO NOT SCALE DRAWINGS.
6.UNLESS OTHERWISE SHOWN OR NOTED, TYPICAL DETAILS SHALL BE USED WHERE APPLICABLE.
7.DETAILS SHALL BE CONSIDERED TYPICAL AT SIMILAR CONDITIONS.
8.SAFETY MEASURES: THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE
CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF THE PERSONS AND PROPERTY AND FOR
INDEPENDENT ENGINEERING REVIEWS OF THESE CONDITIONS. THE ARCHITECT'S OR ENGINEER'S JOB SITE
REVIEW IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY
MEASURES.
9.FIRE RATING REQUIREMENTS PER STATE AND LOCAL CODES.
10.CONSTRUCTION WORK SHALL NOT CREATE DUST, DIRT, OR OTHER SUCH INCONVENIENCES TO THE MALL
AND OTHER MALL TENANTS.
11.CONSTRUCTION OPERATION SHALL NOT BLOCK HALLWAYS OR MEANS OF EGRESS.
12.WITHIN THESE PLANS AND SPECIFICATIONS, "TENANT" IMPLIES:
AND "LANDLORD" IMPLIES:
13.THE WORK IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR ("GC HEREIN) UNLESS NOTED
OTHERWISE. SEE SCOPE OF WORK/RESPONSIBILITY SCHEDULE FOR WORK BY GC.
14.THE TERMS "CONTRACTOR" AND "GC" REFER TO THE TENANT'S GENERAL CONTRACTOR AND THE
GENERAL CONTRACTOR'S SUB-CONTRACTORS. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO
DETERMINE THE DIVISION OF WORK AMONG THE GC'S SUBCONTRACTORS (DRYWALL, ELECTRICAL,
MECHANICAL, ETC.).
15.THE TERMS "FIXTURE MANUFACTURER" AND "FM" REFER TO THE TENANT'S FIXTURE MANUFACTURER. GC
TO REFER TO SECTION 01700 'CLEANING' FOR RESPONSIBILITIES WITH REGARDS TO FIXTURES.
16.DIMENSIONS ARE FROM FINISH TO FINISH UNLESS NOTED OTHERWISE.
17.COMBUSTIBLE MATERIALS SHALL NOT BE USED ABOVE CEILING LINE.
18.MATERIALS WITH A FLAME SPREAD GREATER THAN 75 SHALL NOT BE USED.
19.WOOD STUDS, BLOCKING, PLYWOOD AND THE LIKE SHALL BE FIRE RETARDANT TREATED.
20.GENERAL CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL SHIPMENTS OF TENANT'S FIXTURES PACKAGE
AND OTHER OWNER FURNISHED MATERIALS UPON ARRIVAL TO THE STORE OR CONTRACTORS STORAGE
AREA. THIS INCLUDES OPENING BOXES AND VERIFYING THEIR CONTENTS AGAINST THE PACKING LIST,
CHECKING FOR ANY DAMAGE AND RECORDING IT ON THE BILL OF LADING PRIOR TO THE DRIVER LEAVING.
THE GENERAL CONTRACTOR WILL BEAR ANY AND ALL COSTS ASSOCIATED WITH MISSING OR DAMAGED
ITEMS FROM THAT TIME UNTIL THE STORE IS TURNED OVER TO THE OWNER.
21.GENERAL CONTRACTOR IS RESPONSIBLE FOR SCREWING STORAGE TOGETHER AND SECURING UNITS TO
WALL USING APPROPRIATE ANCHORS FOR WALL CONDITIONS. FIXTURE INSTALLATION PER AWI PREMIUM
GRADE STANDARDS.
22.BIDDING GENERAL CONTRACTOR AND SUBCONTRACTORS MUST VISIT THE SITE PRIOR TO SUBMITTING
BIDS. DEMOLITION AND MODIFICATIONS REQUIRED TO EXISTING SPACE TO COMPLY WITH THESE
DOCUMENTS SHALL BE NOTED AND COMMUNICATED TO ARCHITECT AND INCLUDED IN BID PROPOSALS.
DEMOLITION REQUIREMENTS SHALL INCLUDE BUT NOT BE LIMITED TO: PARTITIONS, DOORS,
STOREFRONT, CEILING, FINISHES, MECHANICAL, PLUMBING, FIRE SPRINKLERS, AND ELECTRICAL. PROVIDE
TEMPORARY ELECTRICAL WHEN REQUIRED.
23.GENERAL CONTRACTOR IS RESPONSIBLE FOR FINAL CLEANING OF STORE PRIOR TO PUNCH LIST. CLEAN UP
TO INCLUDE BUT NOT BE LIMITED TO: GLASS CLEANING, REMOVING MARKS ON WALL SURFACES, CARPET
FINAL CLEANING, TILE (VCT AND CERAMIC) POLISHING, DUSTING FIXTURES AND STOREFRONT SIGN,
BROOM CLEANING ALL AREAS OF TENANT SPACE.
24.GENERAL CONTRACTOR, SUBCONTRACTOR, AND VENDORS WAIVE ALL CLAIMS AGAINST THE ARCHITECT
AND THE ARCHITECT'S CONSULTANTS FOR CONSEQUENTIAL DAMAGES ARISING OUT OF OR RELATING TO
THIS PROJECT. THIS WAIVER IS APPLICABLE, WITHOUT LIMITATION, TO ALL CONSEQUENTIAL DAMAGES.
GENERAL NOTES
LONE CATTLE ITHACA, LLC
SLEEP NUMBER
VICINITY MAP
NORTH
LOCATION MAP
NORTH
NO.I HEREBY CERTIFY THAT THIS PLAN,DIRECT SUPERVISION AND THAT I AMPRELIMINARYUNDER THE LAWS IN THE STATE OFPREPARED BY ME OR UNDER MYREVISIONBYDATEDOCUMENT DATEDRAWN BYDATEISSUED FORCHECKED BYSHEETTITLEREPORT, SPECIFICATION WASPROJECT:LM PROJECT NO.SHEETS COVERED BY THIS SEAL:EXP. DATEREG.NO.A DULY REGISTERED ARCHITECTOWNER:A S S O C I A T E SL T DCONCEPT BY:10907 VALLEY VIEW ROADEDEN PRAIRIE, MINNESOTA 55344FAX 952-944-7585PHONE 952-944-7576C 2020 L&M ASSOCIATES, LTD. ALL RIGHTS RESERVEDFINALPERMIT719 S. MEADOW ST.SUITE 1AITHACA, NY 1485023 DECEMBER 2020MAESLEEP NUMBER1001 3RD AVE. S.MINNEAPOLIS, MN 554042004.1070NEW YORKARCHITECTURAL02416930 JUNE 2023SN STORE #TBD4/14/21RMMSLEEP NUMBER
LOD
NORTHSLEEP NUMBER
PROJECT MANAGER
LANDLORD
REPRESENTATIVE
ARCHITECTURAL
DIRECTOR
ARCHITECTURAL
PROJECT MANAGER
L&M ASSOCIATES LTD.
SLEEP NUMBER
RESPONSIBILITY COMPANY CONTACT PHONEFAX
PROJECT TEAM
763.551.6814JODI HANNA
jodi.hanna@sleepnumber.com
RAY MAZOROL
mazorol@L-M.com
952.944.7576
952.944.7585
L&M ASSOCIATES LTD.
MATTHEWS RETAIL
ADVISORS
DALTON BARNES
dalton.barnes@alphareadvisors.com
MARK EBNER
ebner@L-M.com
952.828.8171
952.944.7585
ARCHITECT DONALD LAUKKAL&M ASSOCIATES LTD.
SLEEP NUMBER
719 S. MEADOW ST.
SUITE 1A
ITHACA, NY 14850
ISSUE LOG
DATE ISSUED FOR
REVISION SUMMARY
MARKDATE DESCRIPTION
12/23/20 BID
1/21/21 REVISION 1 - BID
4/14/21 REVISION 2 - PERMIT
11/21/21 TENANT CHANGES AND CORRECTIONS
24/13/21 TENANT CHANGE & CORRECTION
MATERIAL SUPPLIER UPON AWARD OF CONTRACT, GC TO CONTACT SUPPLIERS TO SCHEDULE DELIVERIES
USING SLEEP NUMBER ORDERING FORM
APEX DESIRAE PARRA
desirae.parra@apexsigngroup.com
210.757.9116STOREFRONT SIGN(S)
FIXTURE
MANUFACTURER
LIGHTING
LUXURY VINYL TILE
CARPET
WINDOW SURFACE
MADSEN FIXTURE
MILLWORK
VILLA LIGHTING
MOHAWK
KARYN CHESLER
Karyn.Chesler@villalighting.com
BRENT JOHNSON
brentj@madsenfixture.com
FC1
FC2
LS
FM
SM
ABB.MATERIAL CONTACTSUPPLIER PHONEFAX
651.982.6220
314.633.0496
MOHAWK 706.879.5671BRITANY MANIS
britany_manis@mohawkind.com
706.879.5671BRITANY MANIS
britany_manis@mohawkind.com
WINDOW FILM DEPOT STEPHEN MALLORY
stephen@windowfilmdepot.com
866.933.3456
DRAWING
DRAWING INDEX
SHT
ISSUED
R
REVISION LOG
1
1/21/21
13
ARCHITECTURAL
COVER SHEET
RESPONSIBILITIES & SPECIFICATIONS
SCHEDULES
CODE COMPLIANCE PLANS
CODE COMPLIANCE PLANS & DETAILS
FIXTURE PLAN
PLAN DETAILS
REFLECTED CEILING PLAN
ROOM FINISH PLAN
INTERIOR SECTIONS & ELEVATIONS
INTERIOR SECTIONS & ELEVATIONS
EXTERIOR ELEVATIONS
EXTERIOR ELEVATIONS
TOTAL SHEETS
G1.0
G1.1
G1.2
A1.0
A1.1
A2.0
A2.1
A3.0
A4.0
A6.0
A6.1
A7.0
A7.1
5
2
4/13/21
4
II-B
NON-SPRINKLERED
MERCANTILE
'A'
1 HOUR
250 FT 0 IN
56 FT 3 IN
2 REQUIRED
2 PROVIDED
SHEET A1.0
75 FT 0 IN
7 FT 0 IN
75 FT 0 IN
28 FT 0 IN
TYPE OF CONSTRUCTION:
OCCUPANCY GROUP:
SEISMIC DESIGN CATEGORY:
FIRE SPRINKLER SYSTEM:
TENANT SEPARATIONS:
MAX. TRAVEL DIST. ALLOWED:
MAX. ACTUAL TRAVEL DISTANCE:
MAX. ACTUAL COMMON DISTANCE 'M':
MAX. COMMON DIST. ALLOWED 'M':
MAX. COMMON DIST. ALLOWED 'S':
MAX. ACTUAL COMMON DISTANCE "S":
EGRESS PLAN:
EXITS:
BUILDING DATA:
WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS & DRAWINGS,
AND SHALL SATISFY APPLICABLE CODES, ORDINANCES, AND REGULATIONS OF GOVERNING BODIES INVOLVED.
ANY MODIFICATION TO THE CONTRACT WORK REQUIRED BY SUCH AUTHORITIES SHALL BE AT THE EXPENSE
OF GC, PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED
AND PAID FOR BY THE CONTRACTOR INVOLVED.
APPLICABLE CODES:
CODE ANALYSIS
1 EXISTING UTILITY SINK PROVIDED
PLUMBING SYSTEMS:
ACCESSIBLE TOILET ROOM:
1 EXISTING ACCESSIBLE HI/LO DRINKING FOUNTAIN PROVIDED
1 EXISTING ACCESSIBLE TOILET ROOM PROVIDED
SERVICE SINK:
DRINKING FOUNTAIN PROVIDED:
2287 SQ. FT.
44 OCCUPANTS
SALES AREA - M
HALLWAY - M 185 SQ. FT.
STORAGE - S1 (TOTAL 300 SQ.FT. / 300 SQ.FT. / OCCUPANT) 1 OCCUPANTS
TOTAL FLOOR AREA GROSS 2887 SQ. FT.
TOTAL OCCUPANT LOAD 45 OCCUPANTS
TOTAL LEASE AREA 3000 SQ. FT.
(TOTAL 2587 SQ.FT. / 60 SQ.FT. / OCCUPANT)
OCCUPANT LOAD BASED ON AREA CALCULATION AND USE:
300 SQ. FT.
BUILDING:
MECHANICAL:
PLUMBING:
ELECTRICAL:
ACCESSIBILITY:
FIRE:
2020 BUILDING CODE OF NY STATE
2018 IBC W/ STATE & LOCAL AMENDMENTS
2020 MECHANICAL CODE OF NY STATE
2018 IMC W/ STATE & LOCAL AMENDMENTS
2020 PLUMBING CODE OF NY STATE
2018 IPC W/ STATE & LOCAL AMENDMENTS
2017 NEC (NFPA 70)
W/ STATE & LOCAL AMENDMENTS
2020 FIRE CODE OF NY STATE
2018 IFC W/ STATE & LOCAL AMENDMENTS
2020 FUEL GAS CODE OF NY STATE
2018 IFGC W/ STATE & LOCAL AMENDMENTS
FUEL GAS:
2020 BUILDING CODE OF NY STATE
2018 IBC; 2009 ANSI A117.1; 2010 ADA;
W/ STATE & LOCAL AMENDMENTS
TOILET - M 58 SQ. FT.
DISPLAY - M 57 SQ. FT.S. MEADOW ST.ITHACA
SKATEPARK