Loading...
HomeMy WebLinkAbout[001] G1.069'-4 1/2"2'-6 1/2"41'-9 1/4"39'-9 7/8"1'-11 3/8"71'-11"G1.0COVER SHEETSLEEP NUMBER 3000 SQ. FT. LEASED AREA VIF 0 SYMBOLS X0 REFERENCE 0'0" AFF NORTH ROOM DESIGNATION DOOR NUMBER FINISH TYPE WALL TYPE KEYNOTE FIXTURE,EQUIMENT SPECIFICATION DIVISION LEASE LINE EXISTING WALL CONSTRUCTION NEW WALL NEW DOOR EXISTING DOOR NORTH ARROW DATUM/ELEVATION GRID LINE ELEVATION REFERENCE SECTION REFERENCE DETAIL REFERENCE REVISION PARTIAL WALL CONSTRUCTION 00000 LBL 100 SALES AREA 0 0 A WT 0 A0.0 0 A0.0 0 A0.0 ABBREVIATIONS ACOUSTICAL CEILING TILE ABOVE DATUM ABOVE DATUM ZERO (0.00") ABOVE FINISHED FLOOR ALTERNATE ALUMINUM APPROXIMATELY BOARD BOTTOM OF CEILING COLUMN CONCRETE CONTINUOUS, CONTINUE CONCRETE MASONRY UNIT DEPTH (DIMENSION) DETAIL DIAMETER DIMENSION DOOR DRAWING ELEVATION ELECTRIC(AL) EQUAL/EQUIVALENT EQUIPMENT EXISTING EXTERIOR FINISH(ED) FLOOR FACE OF FINISH FIBERGLASS REINF PANEL FIRE RESISTANT TREATED GAUGE GYPSUM BOARD HANDICAPPED HARDWARE HOLLOW METAL HORIZONTAL HOUR HEIGHT HEATING/VENTILATION AIR CONDITIONING INTERIOR JOINT LAMINATE LIGHT LANDLORD MAXIMUM MECHANICAL MINIMUM MISCELLANEOUS MOISTURE RESISTANT MOUNTED METAL NOT IN CONTRACT NUMBER NOT TO SCALE OVER ALL ON CENTER(S) OUTSIDE DIAMETER/DIMENSION OPPOSITE PARTIAL PARTICLE BOARD PLASTIC LAMINATE PROJECT MANUAL PLYWOOD RADIUS REQUIRED REFER(ENCE) REVERSE SCHEDULE SHEET SIMILAR SPECIFICATION(S) SQUARE STAINLESS STEEL STANDARD STEEL SYMMETRICAL TO BE DETERMINED THICK TOP OF TYPICAL UNDERWRITER LABORATORIES UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL VERIFY IN FIELD WIDTH (DIMENSION) WITH WOOD WELDED WIRE FABRIC ACT AD ADZ AFF ALT ALUM APPROX BD B/O CLG COL CONC CONT CMU D DTL DIA DIM DR DWG EL ELEC EQ EQUIP EX EXT FIN FLR FOF FRP FRT GA GYP BD HC HDWR HM HORZ HR HT/H HVAC INT JT LAM LT LL MAX MECH MIN MISC MR MTD MTL NIC NO NTS OA OC OD OPP PART PARTBD PLAT PM PLYWD R REQD REF REV SCHD SHT SIM SPEC SQ SS STD STL SYM TBD THK T/O TYP UL UNO VCT VERT VIF W W/ WD WWF 1.WORK DELINEATED IN THESE DRAWINGS AND SPECIFICATIONS SHALL CONFORM TO CODES, STANDARDS AND REGULATIONS THAT GOVERN IN THE JURISDICTION IN WHICH THE WORK IS PERFORMED. 2.REQUIREMENTS AND REGULATIONS PERTAINING TO THE HANDICAPPED MUST BE INCORPORATED IN THE WORK EVEN THOUGH THEY MAY NOT BE LISTED INDIVIDUALLY AND SEPARATELY IN EITHER THE DRAWINGS OR SPECIFICATIONS. 3.IN LOCATIONS WHERE CONCRETE SLAB IS RECENTLY POURED (WITHIN 12 MONTHS PRIOR TO START OF CONSTRUCTION) GC IS RESPONSIBLE FOR PERFORMING A MOISTURE TEST OF SLAB TO INSURE PROPER ADHESION OF CARPET MASTIC TO SLAB. NOTIFY SLEEP NUMBER PROJECT MANAGER IF HIGH MOISTURE CONTENT IS A PROBLEM. 4.COMPARE FIELD CONDITIONS WITH ARCHITECTURAL AND ENGINEERING DRAWINGS. ANY DISCREPANCIES SHALL BE DIRECTED TO THE ARCHITECT FOR CLARIFICATION PRIOR TO FABRICATION AND/OR CONSTRUCTION. SUBMIT ALL NECESSARY SHOP DRAWINGS PRIOR TO FABRICATION FOR APPROVAL BY ARCHITECT. NO INFORMATION OR DETAILS ON THESE SHEETS MAY BE USED WITHOUT THE PERMISSION OF SLEEP NUMBER CORPORATION OR THE ARCHITECT. 5.DO NOT SCALE DRAWINGS. 6.UNLESS OTHERWISE SHOWN OR NOTED, TYPICAL DETAILS SHALL BE USED WHERE APPLICABLE. 7.DETAILS SHALL BE CONSIDERED TYPICAL AT SIMILAR CONDITIONS. 8.SAFETY MEASURES: THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF THE PERSONS AND PROPERTY AND FOR INDEPENDENT ENGINEERING REVIEWS OF THESE CONDITIONS. THE ARCHITECT'S OR ENGINEER'S JOB SITE REVIEW IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES. 9.FIRE RATING REQUIREMENTS PER STATE AND LOCAL CODES. 10.CONSTRUCTION WORK SHALL NOT CREATE DUST, DIRT, OR OTHER SUCH INCONVENIENCES TO THE MALL AND OTHER MALL TENANTS. 11.CONSTRUCTION OPERATION SHALL NOT BLOCK HALLWAYS OR MEANS OF EGRESS. 12.WITHIN THESE PLANS AND SPECIFICATIONS, "TENANT" IMPLIES: AND "LANDLORD" IMPLIES: 13.THE WORK IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR ("GC HEREIN) UNLESS NOTED OTHERWISE. SEE SCOPE OF WORK/RESPONSIBILITY SCHEDULE FOR WORK BY GC. 14.THE TERMS "CONTRACTOR" AND "GC" REFER TO THE TENANT'S GENERAL CONTRACTOR AND THE GENERAL CONTRACTOR'S SUB-CONTRACTORS. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE DIVISION OF WORK AMONG THE GC'S SUBCONTRACTORS (DRYWALL, ELECTRICAL, MECHANICAL, ETC.). 15.THE TERMS "FIXTURE MANUFACTURER" AND "FM" REFER TO THE TENANT'S FIXTURE MANUFACTURER. GC TO REFER TO SECTION 01700 'CLEANING' FOR RESPONSIBILITIES WITH REGARDS TO FIXTURES. 16.DIMENSIONS ARE FROM FINISH TO FINISH UNLESS NOTED OTHERWISE. 17.COMBUSTIBLE MATERIALS SHALL NOT BE USED ABOVE CEILING LINE. 18.MATERIALS WITH A FLAME SPREAD GREATER THAN 75 SHALL NOT BE USED. 19.WOOD STUDS, BLOCKING, PLYWOOD AND THE LIKE SHALL BE FIRE RETARDANT TREATED. 20.GENERAL CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL SHIPMENTS OF TENANT'S FIXTURES PACKAGE AND OTHER OWNER FURNISHED MATERIALS UPON ARRIVAL TO THE STORE OR CONTRACTORS STORAGE AREA. THIS INCLUDES OPENING BOXES AND VERIFYING THEIR CONTENTS AGAINST THE PACKING LIST, CHECKING FOR ANY DAMAGE AND RECORDING IT ON THE BILL OF LADING PRIOR TO THE DRIVER LEAVING. THE GENERAL CONTRACTOR WILL BEAR ANY AND ALL COSTS ASSOCIATED WITH MISSING OR DAMAGED ITEMS FROM THAT TIME UNTIL THE STORE IS TURNED OVER TO THE OWNER. 21.GENERAL CONTRACTOR IS RESPONSIBLE FOR SCREWING STORAGE TOGETHER AND SECURING UNITS TO WALL USING APPROPRIATE ANCHORS FOR WALL CONDITIONS. FIXTURE INSTALLATION PER AWI PREMIUM GRADE STANDARDS. 22.BIDDING GENERAL CONTRACTOR AND SUBCONTRACTORS MUST VISIT THE SITE PRIOR TO SUBMITTING BIDS. DEMOLITION AND MODIFICATIONS REQUIRED TO EXISTING SPACE TO COMPLY WITH THESE DOCUMENTS SHALL BE NOTED AND COMMUNICATED TO ARCHITECT AND INCLUDED IN BID PROPOSALS. DEMOLITION REQUIREMENTS SHALL INCLUDE BUT NOT BE LIMITED TO: PARTITIONS, DOORS, STOREFRONT, CEILING, FINISHES, MECHANICAL, PLUMBING, FIRE SPRINKLERS, AND ELECTRICAL. PROVIDE TEMPORARY ELECTRICAL WHEN REQUIRED. 23.GENERAL CONTRACTOR IS RESPONSIBLE FOR FINAL CLEANING OF STORE PRIOR TO PUNCH LIST. CLEAN UP TO INCLUDE BUT NOT BE LIMITED TO: GLASS CLEANING, REMOVING MARKS ON WALL SURFACES, CARPET FINAL CLEANING, TILE (VCT AND CERAMIC) POLISHING, DUSTING FIXTURES AND STOREFRONT SIGN, BROOM CLEANING ALL AREAS OF TENANT SPACE. 24.GENERAL CONTRACTOR, SUBCONTRACTOR, AND VENDORS WAIVE ALL CLAIMS AGAINST THE ARCHITECT AND THE ARCHITECT'S CONSULTANTS FOR CONSEQUENTIAL DAMAGES ARISING OUT OF OR RELATING TO THIS PROJECT. THIS WAIVER IS APPLICABLE, WITHOUT LIMITATION, TO ALL CONSEQUENTIAL DAMAGES. GENERAL NOTES LONE CATTLE ITHACA, LLC SLEEP NUMBER VICINITY MAP NORTH LOCATION MAP NORTH NO.I HEREBY CERTIFY THAT THIS PLAN,DIRECT SUPERVISION AND THAT I AMPRELIMINARYUNDER THE LAWS IN THE STATE OFPREPARED BY ME OR UNDER MYREVISIONBYDATEDOCUMENT DATEDRAWN BYDATEISSUED FORCHECKED BYSHEETTITLEREPORT, SPECIFICATION WASPROJECT:LM PROJECT NO.SHEETS COVERED BY THIS SEAL:EXP. DATEREG.NO.A DULY REGISTERED ARCHITECTOWNER:A S S O C I A T E SL T DCONCEPT BY:10907 VALLEY VIEW ROADEDEN PRAIRIE, MINNESOTA 55344FAX 952-944-7585PHONE 952-944-7576C 2020 L&M ASSOCIATES, LTD. ALL RIGHTS RESERVEDFINALPERMIT719 S. MEADOW ST.SUITE 1AITHACA, NY 1485023 DECEMBER 2020MAESLEEP NUMBER1001 3RD AVE. S.MINNEAPOLIS, MN 554042004.1070NEW YORKARCHITECTURAL02416930 JUNE 2023SN STORE #TBD4/14/21RMMSLEEP NUMBER LOD NORTHSLEEP NUMBER PROJECT MANAGER LANDLORD REPRESENTATIVE ARCHITECTURAL DIRECTOR ARCHITECTURAL PROJECT MANAGER L&M ASSOCIATES LTD. SLEEP NUMBER RESPONSIBILITY COMPANY CONTACT PHONEFAX PROJECT TEAM 763.551.6814JODI HANNA jodi.hanna@sleepnumber.com RAY MAZOROL mazorol@L-M.com 952.944.7576 952.944.7585 L&M ASSOCIATES LTD. MATTHEWS RETAIL ADVISORS DALTON BARNES dalton.barnes@alphareadvisors.com MARK EBNER ebner@L-M.com 952.828.8171 952.944.7585 ARCHITECT DONALD LAUKKAL&M ASSOCIATES LTD. SLEEP NUMBER 719 S. MEADOW ST. SUITE 1A ITHACA, NY 14850 ISSUE LOG DATE ISSUED FOR REVISION SUMMARY MARKDATE DESCRIPTION 12/23/20 BID 1/21/21 REVISION 1 - BID 4/14/21 REVISION 2 - PERMIT 11/21/21 TENANT CHANGES AND CORRECTIONS 24/13/21 TENANT CHANGE & CORRECTION MATERIAL SUPPLIER UPON AWARD OF CONTRACT, GC TO CONTACT SUPPLIERS TO SCHEDULE DELIVERIES USING SLEEP NUMBER ORDERING FORM APEX DESIRAE PARRA desirae.parra@apexsigngroup.com 210.757.9116STOREFRONT SIGN(S) FIXTURE MANUFACTURER LIGHTING LUXURY VINYL TILE CARPET WINDOW SURFACE MADSEN FIXTURE MILLWORK VILLA LIGHTING MOHAWK KARYN CHESLER Karyn.Chesler@villalighting.com BRENT JOHNSON brentj@madsenfixture.com FC1 FC2 LS FM SM ABB.MATERIAL CONTACTSUPPLIER PHONEFAX 651.982.6220 314.633.0496 MOHAWK 706.879.5671BRITANY MANIS britany_manis@mohawkind.com 706.879.5671BRITANY MANIS britany_manis@mohawkind.com WINDOW FILM DEPOT STEPHEN MALLORY stephen@windowfilmdepot.com 866.933.3456 DRAWING DRAWING INDEX SHT ISSUED R REVISION LOG 1 1/21/21 13 ARCHITECTURAL COVER SHEET RESPONSIBILITIES & SPECIFICATIONS SCHEDULES CODE COMPLIANCE PLANS CODE COMPLIANCE PLANS & DETAILS FIXTURE PLAN PLAN DETAILS REFLECTED CEILING PLAN ROOM FINISH PLAN INTERIOR SECTIONS & ELEVATIONS INTERIOR SECTIONS & ELEVATIONS EXTERIOR ELEVATIONS EXTERIOR ELEVATIONS TOTAL SHEETS G1.0 G1.1 G1.2 A1.0 A1.1 A2.0 A2.1 A3.0 A4.0 A6.0 A6.1 A7.0 A7.1 5 2 4/13/21 4 II-B NON-SPRINKLERED MERCANTILE 'A' 1 HOUR 250 FT 0 IN 56 FT 3 IN 2 REQUIRED 2 PROVIDED SHEET A1.0 75 FT 0 IN 7 FT 0 IN 75 FT 0 IN 28 FT 0 IN TYPE OF CONSTRUCTION: OCCUPANCY GROUP: SEISMIC DESIGN CATEGORY: FIRE SPRINKLER SYSTEM: TENANT SEPARATIONS: MAX. TRAVEL DIST. ALLOWED: MAX. ACTUAL TRAVEL DISTANCE: MAX. ACTUAL COMMON DISTANCE 'M': MAX. COMMON DIST. ALLOWED 'M': MAX. COMMON DIST. ALLOWED 'S': MAX. ACTUAL COMMON DISTANCE "S": EGRESS PLAN: EXITS: BUILDING DATA: WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS & DRAWINGS, AND SHALL SATISFY APPLICABLE CODES, ORDINANCES, AND REGULATIONS OF GOVERNING BODIES INVOLVED. ANY MODIFICATION TO THE CONTRACT WORK REQUIRED BY SUCH AUTHORITIES SHALL BE AT THE EXPENSE OF GC, PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE CONTRACTOR INVOLVED. APPLICABLE CODES: CODE ANALYSIS 1 EXISTING UTILITY SINK PROVIDED PLUMBING SYSTEMS: ACCESSIBLE TOILET ROOM: 1 EXISTING ACCESSIBLE HI/LO DRINKING FOUNTAIN PROVIDED 1 EXISTING ACCESSIBLE TOILET ROOM PROVIDED SERVICE SINK: DRINKING FOUNTAIN PROVIDED: 2287 SQ. FT. 44 OCCUPANTS SALES AREA - M HALLWAY - M 185 SQ. FT. STORAGE - S1 (TOTAL 300 SQ.FT. / 300 SQ.FT. / OCCUPANT) 1 OCCUPANTS TOTAL FLOOR AREA GROSS 2887 SQ. FT. TOTAL OCCUPANT LOAD 45 OCCUPANTS TOTAL LEASE AREA 3000 SQ. FT. (TOTAL 2587 SQ.FT. / 60 SQ.FT. / OCCUPANT) OCCUPANT LOAD BASED ON AREA CALCULATION AND USE: 300 SQ. FT. BUILDING: MECHANICAL: PLUMBING: ELECTRICAL: ACCESSIBILITY: FIRE: 2020 BUILDING CODE OF NY STATE 2018 IBC W/ STATE & LOCAL AMENDMENTS 2020 MECHANICAL CODE OF NY STATE 2018 IMC W/ STATE & LOCAL AMENDMENTS 2020 PLUMBING CODE OF NY STATE 2018 IPC W/ STATE & LOCAL AMENDMENTS 2017 NEC (NFPA 70) W/ STATE & LOCAL AMENDMENTS 2020 FIRE CODE OF NY STATE 2018 IFC W/ STATE & LOCAL AMENDMENTS 2020 FUEL GAS CODE OF NY STATE 2018 IFGC W/ STATE & LOCAL AMENDMENTS FUEL GAS: 2020 BUILDING CODE OF NY STATE 2018 IBC; 2009 ANSI A117.1; 2010 ADA; W/ STATE & LOCAL AMENDMENTS TOILET - M 58 SQ. FT. DISPLAY - M 57 SQ. FT.S. MEADOW ST.ITHACA SKATEPARK