HomeMy WebLinkAbout[012] A7.0
[001] G1.0.pdf
69'-4 1/2" 2'-6 1/2" 41'-9 1/4" 39'-9 7/8" 1'-11 3/8" 71'-11" G1.0 COVER SHEET SLEEP NUMBER 3000 SQ. FT. LEASED AREA VIF 0 SYMBOLS X0 REFERENCE 0'0" AFF NORTH ROOM DESIGNATION DOOR NUMBER
FINISH TYPE WALL TYPE KEYNOTE FIXTURE,EQUIMENT SPECIFICATION DIVISION LEASE LINE EXISTING WALL CONSTRUCTION NEW WALL NEW DOOR EXISTING DOOR NORTH ARROW DATUM/ELEVATION GRID LINE ELEVATION
REFERENCE SECTION REFERENCE DETAIL REFERENCE REVISION PARTIAL WALL CONSTRUCTION 00000 LBL 100 SALES AREA 0 0 A WT 0 A0.0 0 A0.0 0 A0.0 ABBREVIATIONS ACOUSTICAL CEILING TILE ABOVE DATUM
ABOVE DATUM ZERO (0.00") ABOVE FINISHED FLOOR ALTERNATE ALUMINUM APPROXIMATELY BOARD BOTTOM OF CEILING COLUMN CONCRETE CONTINUOUS, CONTINUE CONCRETE MASONRY UNIT DEPTH (DIMENSION) DETAIL
DIAMETER DIMENSION DOOR DRAWING ELEVATION ELECTRIC(AL) EQUAL/EQUIVALENT EQUIPMENT EXISTING EXTERIOR FINISH(ED) FLOOR FACE OF FINISH FIBERGLASS REINF PANEL FIRE RESISTANT TREATED GAUGE
GYPSUM BOARD HANDICAPPED HARDWARE HOLLOW METAL HORIZONTAL HOUR HEIGHT HEATING/VENTILATION AIR CONDITIONING INTERIOR JOINT LAMINATE LIGHT LANDLORD MAXIMUM MECHANICAL MINIMUM MISCELLANEOUS
MOISTURE RESISTANT MOUNTED METAL NOT IN CONTRACT NUMBER NOT TO SCALE OVER ALL ON CENTER(S) OUTSIDE DIAMETER/DIMENSION OPPOSITE PARTIAL PARTICLE BOARD PLASTIC LAMINATE PROJECT MANUAL
PLYWOOD RADIUS REQUIRED REFER(ENCE) REVERSE SCHEDULE SHEET SIMILAR SPECIFICATION(S) SQUARE STAINLESS STEEL STANDARD STEEL SYMMETRICAL TO BE DETERMINED THICK TOP OF TYPICAL UNDERWRITER
LABORATORIES UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL VERIFY IN FIELD WIDTH (DIMENSION) WITH WOOD WELDED WIRE FABRIC ACT AD ADZ AFF ALT ALUM APPROX BD B/O CLG COL CONC
CONT CMU D DTL DIA DIM DR DWG EL ELEC EQ EQUIP EX EXT FIN FLR FOF FRP FRT GA GYP BD HC HDWR HM HORZ HR HT/H HVAC INT JT LAM LT LL MAX MECH MIN MISC MR MTD MTL NIC NO NTS OA OC OD OPP
PART PARTBD PLAT PM PLYWD R REQD REF REV SCHD SHT SIM SPEC SQ SS STD STL SYM TBD THK T/O TYP UL UNO VCT VERT VIF W W/ WD WWF 1. WORK DELINEATED IN THESE DRAWINGS AND SPECIFICATIONS
SHALL CONFORM TO CODES, STANDARDS AND REGULATIONS THAT GOVERN IN THE JURISDICTION IN WHICH THE WORK IS PERFORMED. 2. REQUIREMENTS AND REGULATIONS PERTAINING TO THE HANDICAPPED MUST
BE INCORPORATED IN THE WORK EVEN THOUGH THEY MAY NOT BE LISTED INDIVIDUALLY AND SEPARATELY IN EITHER THE DRAWINGS OR SPECIFICATIONS. 3. IN LOCATIONS WHERE CONCRETE SLAB IS RECENTLY
POURED (WITHIN 12 MONTHS PRIOR TO START OF CONSTRUCTION) GC IS RESPONSIBLE FOR PERFORMING A MOISTURE TEST OF SLAB TO INSURE PROPER ADHESION OF CARPET MASTIC TO SLAB. NOTIFY SLEEP NUMBER
PROJECT MANAGER IF HIGH MOISTURE CONTENT IS A PROBLEM. 4. COMPARE FIELD CONDITIONS WITH ARCHITECTURAL AND ENGINEERING DRAWINGS. ANY DISCREPANCIES SHALL BE DIRECTED TO THE ARCHITECT
FOR CLARIFICATION PRIOR TO FABRICATION AND/OR CONSTRUCTION. SUBMIT ALL NECESSARY SHOP DRAWINGS PRIOR TO FABRICATION FOR APPROVAL BY ARCHITECT. NO INFORMATION OR DETAILS ON THESE SHEETS
MAY BE USED WITHOUT THE PERMISSION OF SLEEP NUMBER CORPORATION OR THE ARCHITECT. 5. DO NOT SCALE DRAWINGS. 6. UNLESS OTHERWISE SHOWN OR NOTED, TYPICAL DETAILS SHALL BE USED WHERE APPLICABLE.
7. DETAILS SHALL BE CONSIDERED TYPICAL AT SIMILAR CONDITIONS. 8. SAFETY MEASURES: THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITIONS OF THE JOB SITE, INCLUDING
SAFETY OF THE PERSONS AND PROPERTY AND FOR INDEPENDENT ENGINEERING REVIEWS OF THESE CONDITIONS. THE ARCHITECT'S OR ENGINEER'S JOB SITE REVIEW IS NOT INTENDED TO INCLUDE REVIEW OF THE
ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES. 9. FIRE RATING REQUIREMENTS PER STATE AND LOCAL CODES. 10. CONSTRUCTION WORK SHALL NOT CREATE DUST, DIRT, OR OTHER SUCH INCONVENIENCES
TO THE MALL AND OTHER MALL TENANTS. 11. CONSTRUCTION OPERATION SHALL NOT BLOCK HALLWAYS OR MEANS OF EGRESS. 12. WITHIN THESE PLANS AND SPECIFICATIONS, "TENANT" IMPLIES: AND "LANDLORD"
IMPLIES: 13. THE WORK IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR ("GC HEREIN) UNLESS NOTED OTHERWISE. SEE SCOPE OF WORK/RESPONSIBILITY SCHEDULE FOR WORK BY GC. 14. THE TERMS "CONTRACTOR"
AND "GC" REFER TO THE TENANT'S GENERAL CONTRACTOR AND THE GENERAL CONTRACTOR'S SUB-CONTRACTORS. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE DIVISION OF WORK AMONG
THE GC'S SUBCONTRACTORS (DRYWALL, ELECTRICAL, MECHANICAL, ETC.). 15. THE TERMS "FIXTURE MANUFACTURER" AND "FM" REFER TO THE TENANT'S FIXTURE MANUFACTURER. GC TO REFER TO SECTION 01700
'CLEANING' FOR RESPONSIBILITIES WITH REGARDS TO FIXTURES. 16. DIMENSIONS ARE FROM FINISH TO FINISH UNLESS NOTED OTHERWISE. 17. COMBUSTIBLE MATERIALS SHALL NOT BE USED ABOVE CEILING
LINE. 18. MATERIALS WITH A FLAME SPREAD GREATER THAN 75 SHALL NOT BE USED. 19. WOOD STUDS, BLOCKING, PLYWOOD AND THE LIKE SHALL BE FIRE RETARDANT TREATED. 20. GENERAL CONTRACTOR IS
RESPONSIBLE FOR CHECKING ALL SHIPMENTS OF TENANT'S FIXTURES PACKAGE AND OTHER OWNER FURNISHED MATERIALS UPON ARRIVAL TO THE STORE OR CONTRACTORS STORAGE AREA. THIS INCLUDES OPENING
BOXES AND VERIFYING THEIR CONTENTS AGAINST THE PACKING LIST, CHECKING FOR ANY DAMAGE AND RECORDING IT ON THE BILL OF LADING PRIOR TO THE DRIVER LEAVING. THE GENERAL CONTRACTOR WILL
BEAR ANY AND ALL COSTS ASSOCIATED WITH MISSING OR DAMAGED ITEMS FROM THAT TIME UNTIL THE STORE IS TURNED OVER TO THE OWNER. 21. GENERAL CONTRACTOR IS RESPONSIBLE FOR SCREWING STORAGE
TOGETHER AND SECURING UNITS TO WALL USING APPROPRIATE ANCHORS FOR WALL CONDITIONS. FIXTURE INSTALLATION PER AWI PREMIUM GRADE STANDARDS. 22. BIDDING GENERAL CONTRACTOR AND SUBCONTRACTORS
MUST VISIT THE SITE PRIOR TO SUBMITTING BIDS. DEMOLITION AND MODIFICATIONS REQUIRED TO EXISTING SPACE TO COMPLY WITH THESE DOCUMENTS SHALL BE NOTED AND COMMUNICATED TO ARCHITECT AND
INCLUDED IN BID PROPOSALS. DEMOLITION REQUIREMENTS SHALL INCLUDE BUT NOT BE LIMITED TO: PARTITIONS, DOORS, STOREFRONT, CEILING, FINISHES, MECHANICAL, PLUMBING, FIRE SPRINKLERS, AND
ELECTRICAL. PROVIDE TEMPORARY ELECTRICAL WHEN REQUIRED. 23. GENERAL CONTRACTOR IS RESPONSIBLE FOR FINAL CLEANING OF STORE PRIOR TO PUNCH LIST. CLEAN UP TO INCLUDE BUT NOT BE LIMITED
TO: GLASS CLEANING, REMOVING MARKS ON WALL SURFACES, CARPET FINAL CLEANING, TILE (VCT AND CERAMIC) POLISHING, DUSTING FIXTURES AND STOREFRONT SIGN, BROOM CLEANING ALL AREAS OF TENANT
SPACE. 24. GENERAL CONTRACTOR, SUBCONTRACTOR, AND VENDORS WAIVE ALL CLAIMS AGAINST THE ARCHITECT AND THE ARCHITECT'S CONSULTANTS FOR CONSEQUENTIAL DAMAGES ARISING OUT OF OR RELATING
TO THIS PROJECT. THIS WAIVER IS APPLICABLE, WITHOUT LIMITATION, TO ALL CONSEQUENTIAL DAMAGES. GENERAL NOTES LONE CATTLE ITHACA, LLC SLEEP NUMBER VICINITY MAP NORTH LOCATION MAP NORTH
NO.I HEREBY CERTIFY THAT THIS PLAN, DIRECT SUPERVISION AND THAT I AM PRELIMINARY UNDER THE LAWS IN THE STATE OF PREPARED BY ME OR UNDER MY REVISIONBY DATE DOCUMENT DATE DRAWN BY DATE
ISSUED FOR CHECKED BY SHEET TITLE REPORT, SPECIFICATION WAS PROJECT: LM PROJECT NO. SHEETS COVERED BY THIS SEAL: EXP. DATE REG.NO. A DULY REGISTERED ARCHITECT OWNER: A S S O C I A T
E SL T D CONCEPT BY: 10907 VALLEY VIEW ROAD EDEN PRAIRIE, MINNESOTA 55344 FAX 952-944-7585PHONE 952-944-7576 C 2020 L&M ASSOCIATES, LTD. ALL RIGHTS RESERVED FINAL PERMIT 719
S. MEADOW ST. SUITE 1A ITHACA, NY 14850 23 DECEMBER 2020 MAESLEEP NUMBER 1001 3RD AVE. S. MINNEAPOLIS, MN 55404 2004.1070 NEW YORK ARCHITECTURAL 024169 30 JUNE 2023 SN STORE #TBD 4/14/21
RMM SLEEP NUMBER LOD NORTH SLEEP NUMBER PROJECT MANAGER LANDLORD REPRESENTATIVE ARCHITECTURAL DIRECTOR ARCHITECTURAL PROJECT MANAGER L&M ASSOCIATES LTD. SLEEP NUMBER RESPONSIBILITY
COMPANY CONTACT PHONE FAX PROJECT TEAM 763.551.6814JODI HANNA jodi.hanna@sleepnumber.com RAY MAZOROL mazorol@L-M.com 952.944.7576 952.944.7585 L&M ASSOCIATES LTD. MATTHEWS RETAIL ADVISORS
DALTON BARNES dalton.barnes@alphareadvisors.com MARK EBNER ebner@L-M.com 952.828.8171 952.944.7585 ARCHITECT DONALD LAUKKA L&M ASSOCIATES LTD. SLEEP NUMBER 719 S. MEADOW ST. SUITE 1A
ITHACA, NY 14850 ISSUE LOG DATE ISSUED FOR REVISION SUMMARY MARKDATE DESCRIPTION 12/23/20 BID 1/21/21 REVISION 1 - BID 4/14/21 REVISION 2 - PERMIT 11/21/21 TENANT CHANGES AND CORRECTIONS
24/13/21 TENANT CHANGE & CORRECTION MATERIAL SUPPLIER UPON AWARD OF CONTRACT, GC TO CONTACT SUPPLIERS TO SCHEDULE DELIVERIES USING SLEEP NUMBER ORDERING FORM APEX DESIRAE PARRA desirae.parra@apexsig
ngroup.com 210.757.9116STOREFRONT SIGN(S) FIXTURE MANUFACTURER LIGHTING LUXURY VINYL TILE CARPET WINDOW SURFACE MADSEN FIXTURE MILLWORK VILLA LIGHTING MOHAWK KARYN CHESLER Karyn.Chesler@villalighting
.com BRENT JOHNSON brentj@madsenfixture.com FC1 FC2 LS FM SM ABB. MATERIAL CONTACT SUPPLIER PHONE FAX 651.982.6220 314.633.0496 MOHAWK 706.879.5671 BRITANY MANIS britany_manis@mohawkind.com
706.879.5671BRITANY MANIS britany_manis@mohawkind.com WINDOW FILM DEPOT STEPHEN MALLORY stephen@windowfilmdepot.com 866.933.3456 DRAWING DRAWING INDEX SHT ISSUED R REVISION LOG 1 1/21/21
13 ARCHITECTURAL COVER SHEET RESPONSIBILITIES & SPECIFICATIONS SCHEDULES CODE COMPLIANCE PLANS CODE COMPLIANCE PLANS & DETAILS FIXTURE PLAN PLAN DETAILS REFLECTED CEILING PLAN ROOM
FINISH PLAN INTERIOR SECTIONS & ELEVATIONS INTERIOR SECTIONS & ELEVATIONS EXTERIOR ELEVATIONS EXTERIOR ELEVATIONS TOTAL SHEETS G1.0 G1.1 G1.2 A1.0 A1.1 A2.0 A2.1 A3.0 A4.0 A6.0 A6.1
A7.0 A7.1 5 2 4/13/21 4 II-B NON-SPRINKLERED MERCANTILE 'A' 1 HOUR 250 FT 0 IN 56 FT 3 IN 2 REQUIRED 2 PROVIDED SHEET A1.0 75 FT 0 IN 7 FT 0 IN 75 FT 0 IN 28 FT 0 IN TYPE OF CONSTRUCTION:
OCCUPANCY GROUP: SEISMIC DESIGN CATEGORY: FIRE SPRINKLER SYSTEM: TENANT SEPARATIONS: MAX. TRAVEL DIST. ALLOWED: MAX. ACTUAL TRAVEL DISTANCE: MAX. ACTUAL COMMON DISTANCE 'M': MAX. COMMON
DIST. ALLOWED 'M': MAX. COMMON DIST. ALLOWED 'S': MAX. ACTUAL COMMON DISTANCE "S": EGRESS PLAN: EXITS: BUILDING DATA: WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE
SPECIFICATIONS & DRAWINGS, AND SHALL SATISFY APPLICABLE CODES, ORDINANCES, AND REGULATIONS OF GOVERNING BODIES INVOLVED. ANY MODIFICATION TO THE CONTRACT WORK REQUIRED BY SUCH AUTHORITIES
SHALL BE AT THE EXPENSE OF GC, PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE CONTRACTOR INVOLVED. APPLICABLE CODES: CODE ANALYSIS
1 EXISTING UTILITY SINK PROVIDED PLUMBING SYSTEMS: ACCESSIBLE TOILET ROOM: 1 EXISTING ACCESSIBLE HI/LO DRINKING FOUNTAIN PROVIDED 1 EXISTING ACCESSIBLE TOILET ROOM PROVIDED SERVICE
SINK: DRINKING FOUNTAIN PROVIDED: 2287 SQ. FT. 44 OCCUPANTS SALES AREA - M HALLWAY - M 185 SQ. FT. STORAGE - S1 (TOTAL 300 SQ.FT. / 300 SQ.FT. / OCCUPANT) 1 OCCUPANTS TOTAL FLOOR
AREA GROSS 2887 SQ. FT. TOTAL OCCUPANT LOAD 45 OCCUPANTS TOTAL LEASE AREA 3000 SQ. FT. (TOTAL 2587 SQ.FT. / 60 SQ.FT. / OCCUPANT) OCCUPANT LOAD BASED ON AREA CALCULATION AND USE: 300
SQ. FT. BUILDING: MECHANICAL: PLUMBING: ELECTRICAL: ACCESSIBILITY: FIRE: 2020 BUILDING CODE OF NY STATE 2018 IBC W/ STATE & LOCAL AMENDMENTS 2020 MECHANICAL CODE OF NY STATE 2018 IMC
W/ STATE & LOCAL AMENDMENTS 2020 PLUMBING CODE OF NY STATE 2018 IPC W/ STATE & LOCAL AMENDMENTS 2017 NEC (NFPA 70) W/ STATE & LOCAL AMENDMENTS 2020 FIRE CODE OF NY STATE 2018 IFC W/
STATE & LOCAL AMENDMENTS 2020 FUEL GAS CODE OF NY STATE 2018 IFGC W/ STATE & LOCAL AMENDMENTS FUEL GAS: 2020 BUILDING CODE OF NY STATE 2018 IBC; 2009 ANSI A117.1; 2010 ADA; W/ STATE
& LOCAL AMENDMENTS TOILET - M 58 SQ. FT. DISPLAY - M 57 SQ. FT. S. MEADOW ST. ITHACA SKATEPARK
[002] G1.1.pdf
G1.1 RESPONSIBILITIES & SPECIFICATIONS NO.I HEREBY CERTIFY THAT THIS PLAN, DIRECT SUPERVISION AND THAT I AM PRELIMINARY UNDER THE LAWS IN THE STATE OF PREPARED BY ME OR UNDER MY REVISIONBY
DATE DOCUMENT DATE DRAWN BY DATE ISSUED FOR CHECKED BY SHEET TITLE REPORT, SPECIFICATION WAS PROJECT: LM PROJECT NO. SHEETS COVERED BY THIS SEAL: EXP. DATE REG.NO. A DULY REGISTERED
ARCHITECT OWNER: A S S O C I A T E SL T D CONCEPT BY: 10907 VALLEY VIEW ROAD EDEN PRAIRIE, MINNESOTA 55344 FAX 952-944-7585PHONE 952-944-7576 C 2020 L&M ASSOCIATES, LTD. ALL
RIGHTS RESERVED FINAL PERMIT 719 S. MEADOW ST. SUITE 1A ITHACA, NY 14850 23 DECEMBER 2020 MAESLEEP NUMBER 1001 3RD AVE. S. MINNEAPOLIS, MN 55404 2004.1070 NEW YORK ARCHITECTURAL 024169
30 JUNE 2023 SN STORE #TBD 4/14/21 RMM AS REQUIRED BY LOCAL BUILDING DEPARTMENT. ALL OTHERS AS REQUIRED BY LOCAL BUILDING AND FIRE DEPARTMENTS. PROVIDED BY AND INSTALLED BY GC AS REQUIRED.
AS REQUIRED. TENANT CONTRACTOR TO PROVIDE JOB SITE PHONE FOR USE BY G.C. AND TENANT. AS REQUIRED BY LANDLORD AND TENANT, GC TO PROVIDE AND INSTALL GRAPHICS ON BARRICADE. DAILY AND FINAL
AT JOB COMPLETION, DUST FREE. INFILL CONCRETE SLAB TO MATCH EXISTING (VIF): 4" CONCRETE SLAB 3000 PSI MIN W/ 6"X6" 10-10 WWM OVER COMPACTED 4" GRANULAR FILL W/ VAPOR BARRIER. COORDINATED.
W/ LL REQUIREMENTS. EXPANSION JOINT MATERIALS FLOOR PATCH AS REQUIRED, ALL FLOORS ARE TO BE MADE SMOOTH AND LEVEL. CORE DRILL OR TRENCH AND PATCH EXISTING SLAB AS REQUIRED FOR COMPLETION
OF WORK. EXISTING TO REMAIN. PROVIDE INCIDENTAL FRAMING INCLUDING BUT NOT LIMITED TO ROOF PENETRATION FRAMING, REINFORCING ANGLES AT RTU, DUCTS, VENTS, ETC. AS REQUIRED TO PERFORM WORK
AS INDICATED IN THESE ARCHITECTURAL, MECHANICAL, AND ELECTRICAL PLANS. WOOD BLOCKING: FIRE RETARDANT TREATED, WHERE REQUIRED PER PLAN. PLYWOOD: FIRE RETARDANT TREATED, WHERE REQUIRED.
WOOD BASE: SUPPLIED IN SHAPES AND PROFILES AS SHOWN. PROVIDE RUBBERIZED ASPHALT SHEET OR LIQUID APPLIED WATERPROOF MEMBRANE AND BASE INSTALLED IN ACCORDANCE WITH LANDLORD REQUIREMENTS.
CAULKING AS REQUIRED AT WEATHER EXPOSED AREAS AND TOILET ROOM. SEE DOOR SCHEDULE. PROVIDE CONCEALED ACCESS PANELS IN GYP BD CLG AND WALLS AS SHOWN OR AS REQD BY CODE. GLAZING SYSTEM
AS DETAILED IN PLANS WITH CUSTOM FINISH. INTERIOR PARTITIONS: 20 GA. METAL STUDS AT 16" O.C. 5/8" TYPE 'X' GYP. BD. LEVEL 5 FINISH 20 GA. METAL STUDS AT 16" O.C. (MAX) AS REQUIRED.
16 GA. METAL JOISTS AS SHOWN / REQUIRED. CEILING/SOFFIT FRAMING: 20 GA. METAL FRAMING MEMBERS AT 16" O.C. (MAX) AT1 AND AT2 AS INDICATED. CARPET SUPPLIED BY VENDOR; INSTALLED BY GC.
SEAL EXPOSED CONCRETE WITH (2) COATS CS1. PRIME AND PAINT (2) FINISH COATS. LANDLORD TO PRIME THE ENTIRE SPACE AND PAINT TOILET ROOM(S) STOREFRONT SIGN: GC TO COORDINATE INSTALLATION
WITH SIGN MANUFACTURER. INTERIOR VINYL SIGNAGE AND GRAPHIC PANELS. GC TO COORD SIGN INSTALLATION WITH PROJECT MANAGER. CLASS A-B-C DRY CHEMICAL 10-POUND EXTINGUISHER AS DESIGNATED
BY THE TENANT AND FIRE MARSHAL; VERIFY LOCATION AND QUANTITY WITH FIRE MARSHAL. STANDARDS, LOW PRESSURE LAMINATE SHELVES (12"DEEP, 5 TIERS), KNIFE BRACKETS. AS REQUIRED; SEE TOILET
ROOM NOTES AND DETAILS. BED PUMP UNITS HEADBOARDS, POS COUNTERS, ACCESSORY UNITS AND FIXTURES TO BE ASSEMBLED BY GC AND INSTALLED PER AWI PREMIUM GRADE STANDARDS. MASTER FORMAT DIVISION/SECTION
010000 GENERAL REQUIREMENTS 014100 REGULATORY REQUIREMENTS .1 BUILDING PLAN CHECK FEE .4 SIGN PERMIT FEES .3 SIGN PLAN CHECK FEE .5 OTHER FEES 014523 TESTING AND INSPECTING SERVICES
TEMPORARY ELECTRICITY015113 015123 TEMPORARY HEATING COOLING & VENT'G 015133 CLEANING AND WASTE MANAGEMENT017400 020000 EXISTING CONDITIONS 024119 SELECTIVE DEMOLITION 030000 CONCRETE
033000 CONCRETE 031500 CONCRETE ACCESSORIES 035319 CONCRETE OVERLAYMENT 038000 CONCRETE CUTTING AND BORING 040000 MASONRY 050000 METALS 051200 BUILDING STRUCTURAL STEEL 054000 COLD
FORMED METAL FRAMING 060000 WOOD, PLASTICS & COMPOSITES 061053 MISCELLANEOUS ROUGH CARPENTRY 061636 WOOD PANEL PRODUCT SHEATHING 064619 WOOD BASE AND SHOE MOLDINGS 070000 THERMAL &
MOISTURE PROTECTION 071100 DAMPPROOFING 079200 JOINT SEALANTS 072400 EXTERIOR INSULATION FINISH SYSTEM 080000 OPENINGS 081100 METAL DOORS AND FRAMES 081400 WOOD DOORS 083100 ACCESS
DOORS AND PANELS 084113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS 088500 GLAZING ACCESSORIES SOLAR CONTROL FILMS 088123 EXTERIOR GLASS GLAZING 090000 FINISHES 092116 GYPSUM BOARD ASSEMBLIES
092116 092216 NON-STRUCTURAL METAL FRAMING 092216 092213 METAL FURRING 052116 LONGSPAN STEEL JOIST FRAMING 092226 SUSPENSION SYSTEMS 092400 CEMENT PLASTERING MASTER FORMAT DIVISION/SECTION
090000 FINISHES (CONTINUED) 092920 SUPPORTS FOR GYPSUM BOARD 093000 TILING 095123 ACOUSTICAL TILE CEILINGS 096513 RESILIENT BASE AND ACCESSORIES 096800 CARPET 068316 FIBERGLASS REINFORCED
PANELING 099723 CONCRETE AND MASONRY COATINGS 099123 EXTERIOR PAINTING 100000 SPECIALTIES 101419 DIMENSIONAL LETTER SIGNAGE 101423 PANEL SIGNAGE 104416.13 PORTABLE FIRE EXTINGUISHERS
105617 WALL-MOUNTED STANDARDS & SHELVING 107313 AWNINGS 102820 DIAPER CHANGING STATIONS 110000 EQUIPMENT 112113 CASH REGISTERS AND CHECKING EQUIP. 112000 COMMERCIAL EQUIPMENT 115213
PROJECTION SCREENS 120000 FURNISHINGS 125383 CUSTOM RETAIL FURNITURE 130000 SPECIAL CONSTRUCTION 140000 CONVEYING EQUIPMENT 210000 FIRE SUPPRESSION 220000 PLUMBING 221000 PLUMBING PIPING
223333 LIGHT COMM. ELECTRIC WATER HEATERS 224200 COMMERCIAL PLUMBING FIXTURES 230000 HVAC 233000 HVAC AIR DISTRIBUTION 233400 HVAC FANS 230900 INSTRUMENTATION & CONTROL FOR HVAC 233313
DAMPERS EX - EXISTING TO REMAIN LLGC - LANDLORD GENERAL CONTRACTOR SN - SLEEP NUMBER (VENDOR) SNGC - TENANT GENERAL CONTRACTOR EXISTING SN VENDOR SNGC SN VENDOR SNGC SCHEDULE OF RESPONSIBILITIES
BY SPECIFICATION SECTION (FINISHES FIXTURES EQUIPMENT) RESPONSIBILITY CODE FURNISH INSTALL FURNISH INSTALL SN VENDOR SNGC SN VENDOR SNGC SEE DOOR SCHEDULE.087100 DOOR HARDWARE TEMPERED
GLASS PER PLANS. 088713-B GLAZING SURFACE FILMS SOLAR GARD WHITE OPAQUE SOLAR CONTROL FILM OR EQUAL, SELF-ADHERING AND CONTAINING ABSORBERS/INHIBITORS TO REDUCE ULTRA VIOLET RAYS AND
SOLAR HEAT GAIN. INSTALL ON INTERIOR SIDE OF GLASS AS INDICATED ON PLANS (GLASS AREAS WHICH ARE NOT TO REMAIN VISIBLE TO INSIDE FROM EXTERIOR) AND PER MANUFACTURER'S INSTRUCTIONS.
088733 DECORATIVE FILMS LLGC EXISTING LLGC EXISTING LLGC EXISTING LLGC 211300 FIRE-SUPPRESSION SPRINKLER SYSTEMS LANDLORD FURNISHES AND INSTALLS IN TOILET ROOM(S) AND STORAGE ROOM(S)
AS REQUIRED BY LOCAL BUILDING DEPARTMENT..2 BUILDING PERMIT FEES AS REQUIRED BY LOCAL BUILDING DEPARTMENT. AS REQUIRED BY LOCAL BUILDING DEPARTMENT. AS REQUIRED BY LOCAL BUILDING DEPARTMENT.
TEMPORARY TELECOMMUNICATIONS TEMPORARY BARRIERS AND ENCLOSURES015600 032000 CONCRETE REINFORCING SEE DOOR SCHEDULE. PER PLANS AND DOOR SCHEDULE. 088713-A DEMISING WALLS: 20 GA. METAL
STUDS AT 16" O.C., SOUNDPROOF INSULATION, 5/8" TYPE X' GYPSUM BOARD; LEVEL 5 FINISH GYPSUM BOARD ASSEMBLIES STOREFRONT FRAMING NON-STRUCTURAL METAL FRAMING 099123 INTERIOR PAINTING
AS REQUIRED; SEE TOILET ROOM NOTES AND DETAILS.102813 TOILET ACCESSORIES 113000 RESIDENTIAL EQUIPMENT 3M PRESTIGE SERIES PR70 CLEAR WINDOW SOLAR CONTROL FILM (NO SUBSTITUTIONS). INSTALL
ON INTERIOR SIDE OF ALL GLASS SURFACES UNLESS NOTED OTHERWISE ON PLANS (GLASS AREAS WHICH ARE TO REMAIN VISIBLE TO INSIDE FROM EXTERIOR, E.G. SALES AREAS) AND PER MANUFACTURER'S INSTRUCTIONS.
COMMUNICATIONS POS TERMINAL CONTACT LOCAL TELEPHONE COMPANY 260000 ELECTRICAL 261000 MED-VOLTAGE ELECTRICAL DISTRIBUTION 272000 DATA COMMUNICATIONS 273000 VOICE COMMUNICATIONS 271000
STRUCTURED CABLING 274000 AUDIO-VISUAL COMMUNICATIONS METERING, PANELS AND POWER DISTRIBUTION ATLAS SOUND FAP40T WHITE 4" SPEAKER. WIRE: IW-2-22GA COPPER TWISTED WIRE CABLE. 10' COILED
AND LABELED AT MUZAK PLAYER. 270000 310000 EARTHWORK 320000 EXTERIOR IMPROVEMENTS 280000 ELECTRONIC SAFETY AND SECURITY 284600 FIRE DETECTION AND ALARM 330000 UTILITIES COORDINATE DEVICES
WITH BUILDING SYSTEMS 237400 PACKAGED OUTDOOR HVAC EQUIPMENT 096519 RESILIANT TILE FLOORING 097200 WALL COVERINGS WC1 274000 AUDIO-VISUAL COMMUNICATIONS AUDIO VISUAL MOUNTING HARDWARE
265100 INTERIOR LIGHTING 262700 LOW-VOLTAGE ELECTRICAL DISTRIBUTION 274000 AUDIO-VISUAL COMMUNICATIONS MONITOR VINYL TILE WITH WATERPROOF MEMBRANE AS REQUIRED. LANDLORD FURNISHES AND
INSTALLS FC1 IN TOILET ROOM(S)
[003] G1.2.pdf
G1.2 SCHEDULES A1 A2 C2 C4 NO.I HEREBY CERTIFY THAT THIS PLAN, DIRECT SUPERVISION AND THAT I AM PRELIMINARY UNDER THE LAWS IN THE STATE OF PREPARED BY ME OR UNDER MY REVISIONBY DATE
DOCUMENT DATE DRAWN BY DATE ISSUED FOR CHECKED BY SHEET TITLE REPORT, SPECIFICATION WAS PROJECT: LM PROJECT NO. SHEETS COVERED BY THIS SEAL: EXP. DATE REG.NO. A DULY REGISTERED ARCHITECT
OWNER: A S S O C I A T E SL T D CONCEPT BY: 10907 VALLEY VIEW ROAD EDEN PRAIRIE, MINNESOTA 55344 FAX 952-944-7585PHONE 952-944-7576 C 2020 L&M ASSOCIATES, LTD. ALL RIGHTS RESERVED
FINAL PERMIT 719 S. MEADOW ST. SUITE 1A ITHACA, NY 14850 23 DECEMBER 2020 MAESLEEP NUMBER 1001 3RD AVE. S. MINNEAPOLIS, MN 55404 2004.1070 NEW YORK ARCHITECTURAL 024169 30 JUNE 2023
SN STORE #TBD 4/14/21 RMM TAG MATERIAL TYPE MANUFACTURER SPECIFICATION COLOR FLAME SPREAD CLASSIFICATION NOTES USG 24"X24"X5/8" 2220 RADAR CLIMAPLUS WHITE CLASS A 15/16" DONN DX WHITE
GRID USG 24"x48" FISSURED 562 SQ WHITE 15/16" DONN DX WHITE GRID CONCRETE SEALER GENERIC PENETRATING SEALER CLEAR (2) COATS OVER EXPOSED SLAB AT1 AT2 ACOUSTIC CEILING TILE CS1 CLASS
A CLASS A ACOUSTIC CEILING TILE SCALE: NA FINISH SCHEDULE FC1 CARPET MOHAWK METALLIC PATH 949 SLATE BURST CLASS 1FC2 MOHAWK CLASS 1LUXURY VINYL TILE PAINT WALLS: LO SHEEN EGGSHELL
LATEX DOORS/JAMBS: SEMI GLOSS ALKYD CEILINGS/SOFFITS: FLAT LATEX PT1 FIBERGLASS REINFORCED PANEL WHITE TOILET ROOM AND UTILITY SINK WAINSCOTFRP CLASS C VINYL BASE JOHNSONITE 168 -
4" COVE BASE THUNDER WALL BASE - STORAGE, TOILET AND UTILITY ROOMSVB1 CLASS 1 WOOD WALL BASEWB1 BY FIXTURE MANUFACTURER 4"X 3/4" MDF BASE PROVIDED BY SC VENDOR, INSTALLED BY SC GC,
FINISH: PT1, SEE DETAIL SHEET A4.1 CLASS A PAINT GLIDDEN PROFESSIONAL 30YY 20/029 MANSARD STONE TOILET ROOM WALLS CLASS APT3 GLIDDEN PROFESSIONAL 50BG 72/006 TULLE WHITE ANTIEK C00158
8"x60" BISCOTTI 831 SALES AREA - BRICK ASHLAR PATTERN, PROVIDED BY SN VENDOR SALES AREA AND TOILET ROOM - 3RD 0FFSET PATTERN, PROVIDED BY SN VENDOR SILVER MYLAR LINEN CUSTOM GRAPHIC
DUAL TEMP WALL COVERINGWC1 WALL COVERING VESCOM CLASS A WHITE CLASS CMARLITE C100-G44 PT4 PAINT BENJAMIN MOORE CLASS A 2063-10 OLD NAVY DISPLAY WALLS: SEE FINISH PLAN FOR LOCATIONS
1. PROVIDE AND INSTALL REESE SMOKE SEAL F-897B AT RATED DOORS. 2. RATED DOORS SHALL HAVE CLOSERS W/O HOLD OPEN DEVICES. 3. EXIT DOOR HARDWARE SHALL COMPLY WITH BUILDING CODE AND ADA
REQUIREMENTS. 4. EXIT DOORS SHALL ALLOW EGRESS WITH ONE SINGLE ACTION DEVICE. 5. RATED DOORS AND HARDWARE SHALL HAVE MANUFACTURERS' RATING LABEL. 6. NO HOLD OPEN DEVICES ON EXTERIOR
ENTRY DOORS. 7. PROVIDE SWEEP AND SEAL ON ALL SERVICE DOORS. 8. ENTRY AND SERVICE DOOR LOCKSETS TO ACCOMMODATE 'BEST LOCK' 7PIN CYLINDER. GC TO PROVIDE TEMPORARY 'CONSTRUCTION' CORES
AND KEYS FOR CONSTRUCTION PERIOD. GC RESPONSIBLE FOR REPLACING CORES UPON COMPLETION OF THE PROJECT WITH CORES PROVIDED BY SC PROJECT MANAGER. 9. DOOR OPENING FORCES SHALL BE THE MINIMUM
ALLOWED BY THE LOCAL CODE AUTHORITY FOR FIRE DOORS AND 5.0 POUNDS MAXIMUM FOR INTERIOR HINGED, SLIDING OR FOLDING DOORS. TYPE HDWR DR/TRIM FIN PAIR 3'0"x7'0" 3'0"x7'0" EXISTING TO REMAIN
EXISTING TO REMAIN OR REPLACE W/ EQUAL AS REQ'D "EMERGENCY EXIT ONLY ALARM WILL SOUND" DECAL "BEST LOCK" 7PIN CYLINDER, SMALL FORMAT BUTTS: EXIT DEVICE: LOCK: A EX.GLAZING SYSTEM EXISTING
EXISTING ENTRY DOORS EXISTING EGRESS DOOR NOTESFRAMESIZESYMBOL 11 PT1 HARDWARE GROUPS: DOOR TYPES: GROUP 1 B EX. HOLLOW METAL3 3 GENERAL DOOR AND HARDWARE NOTES: TYPE A EXISTING
FRAMED GLASS SCALE: NA DOOR AND HARDWARE SCHEDULE 3'0"x7'0" PT1 EX. HOLLOW METAL2 3'0"x7'0" C5 5 EXISTING STORAGE ROOM DOOR EXISTING TO REMAIN CRL LADDER PULLS 1-1/2" DIA X 60" LENGTH,
FINISH: SATIN ALUMINUM, OR MATCH GLAZING SYSTEM FIN (VERIFY WITH ARCH) INSTALLED BY GC "BEST LOCK" 7PIN CYLINDER, SMALL FORMAT THRESHOLD AND WEATHER STRIP INTEGRAL TO SYSTEM. DECAL
W/ 1" MIN. HIGH LETTERING 'DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED.' BUTTS: PULL SET: LOCK: MISC: TYPE B EXISTING HOLLOW METAL GROUP 3 GROUP 5 2 EXISTING TOILET ROOM
DOOR B 11/2 PAIR, 4 1/2" BALDWIN 1046 BUTTON TIP 264 FINISH SCHLAGE A-SERIES LEVON (LEVER) A40 626 FINISH LCN 4020 PUSH SIDE OR 4020T PULL SIDE (SIDE OF DOOR OPPOSITE FROM SALES AREA),
ALUMINUM FINISH IVES 8400-US28-8X32-B4ECS PUSH SIDE BALDWIN 4000 264 FINISH BUTTS: PRIVACY SET: CLOSER: KICKPLATE: STOP: GROUP 2 1 1/2 PAIR, 4 1/2" BALDWIN 1046 BUTTON TIP 264 FINISH
SCHLAGE A-SERIES LEVON (LEVER) A70 626 FINISH "BEST LOCK" 7PIN CYLINDER, SMALL FORMAT LCN 4020 PUSH SIDE OR 4020T PULL SIDE (SIDE OF DOOR OPPOSITE FROM SALES AREA) ALUMINUM FINISH IVES
8400-US28-8X32-B4ECS PUSH SIDE BALDWIN 4000 264 FINISH BUTTS: CLASSROOM SET: LOCK: CLOSER: KICK PLATE: STOP: 11/2 PAIR, 4 1/2" BALDWIN 1046 BUTTON TIP 264 FINISH SCHLAGE A-SERIES LEVON
(LEVER HANDLE) A10 626 FINISH BUTTS: PASSAGE SET: GROUP 4 3'0"x7'0" B EXISTING HOLLOW METAL 44 EXISTING DISPLAY DOOR; PT1 SALES SIDE PT4 DISPLAY SIDE PT4 PT1 EX.GLAZING SYSTEM EXISTING
TYPE C EXISTING FRAMED GLASS H EMERGENCY LIGHT EXITRONIX LL50-H-WH UNIVERSAL EMERGENCY LIGHT J VEX-U-BP-WB-WH UNIVERSAL LED EXIT SIGN - WHITE DETERMINE NO. OF FACES PER PLANEXIT SIGN
EXITRONIX 15.3 WATTS 21.4 WATTS SYM FIXTURE MFR DESCRIPTION MODEL NUMBER MAX WATTAGE COMMENTSID SCALE: NA LIGHT FIXTURE SCHEDULE A JUNO R620L 30K 80CRI PDIM VBS WH AHR620 WHT 275 HCLBL
275 TRACK HEAD - SEE LIGHTING PLAN FOR LAYOUTLED TRACK MTD HEAD T T2WH, T4WH TRACK FOR "A" HEADS SURF MTD TRACK W/CONNECTIONS JUNO B HC620D010 HM612830 61WDW 6" LED RECESSED DOWNLIGHT
HALO RECESSED DOWNLIGHTING, 'B-NL'=NIGHT LIGHTING FIXTURE, 'B-EM'=EMERGENCY LIGHTING FIXTURE, RECESSED DOWNLIGHTING WITH FACTORY INSTALLED 7W EMERGENCY BATTERY BACK UP F8 8' LINEAR
LED ORACLE BY ELITE 8-OEC-LED-8000L-DIM10MVOLT-40K-85 STORAGE ROOM 61 WATTS CF HC410D010 HM412830 41WDW 4" LED RECESSED DOWNLIGHT HALO DOWNLIGHT AT STOREFRONT 10.9 WATTS S 41161-962
TOILET ROOM (2) LAMP VANITY FIXTURE. CENTER OVER LAVATORY AT 7'-0" AFF TO CENTER OF WALL PLATESCONCE SEA GULL LIGHTING 100 WATTS P 30" PENDANT H-VLSN3038-L1 HI-LITE MFG 13 WATTS - (ALL
ARE EXISTING) FINISH: 128-GOLD INTERIOR, 93-WHITE EXTERIOR & CANOPY MOUNTING: CORD W/ AIRCRAFT CABLE MOUNT B/O FIXTURE AT 8'-0" AFF, 1250 LUMENS, 3000K B2 14.8 WATTS SLD612830WH6" LED
SURFACE DOWNLIGHT HALO TOILET ROOM S SCALE: NA CEILING SYMBOLS SYMBOL DESCRIPTION COMMENTS EXHAUST FAN SPEAKER SUPPLY AIR RETURN AIR MANF. MODEL # ATLAS SOUND FAP40T SEE RESPONSIBILITY
SCHEDULE 1 1
[004] A1.0.pdf
CODE COMPLIANCE PLAN 48" MIN 101 SALES AREA 2287 SF 103 STORAGE 300 SF 104 TOILET 58 SF 105 DISPLAY 57 SF ACTUAL TRAVEL DISTANCE 52'-9" FROM "S-1" TO AN EXIT ACTUAL COMMON PATH FOR 'S'
OCCUPANCIES 28'-0"<75'-0" ACTUAL TRAVEL DISTANCE 52'-9" TO AN EXIT ACTUAL COMMON PATH FOR 'M' OCCUPANCIES 7'-0"<75'-0" 102 HALLWAY 185 SF ACTUAL TRAVEL DISTANCE 56'-3" TO AN EXIT 5'-5
1/2" 5'-2" 3'-0" 4'-6 1/2" Ø 60" MIN Ø 60" MIN 3'-0" 4'-9 1/4" 4'-5 1/4" 5'-10" 3'-6 3/4" 2'-11 3/4" GC TO PROVIDE & INSTALL 2A:10B:C DRY CHEMICAL FIRE EXTINGUISHER LOCATED PER FIRE
MARSHAL PROVIDE TACTILE EXIT SIGNAGE SEE DETAIL A3/A1.1 GC TO PROVIDE & INSTALL 2A:10B:C DRY CHEMICAL FIRE EXTINGUISHER LOCATED PER FIRE MARSHAL PROVIDE TACTILE EXIT SIGNAGE SEE DETAIL
A3/A1.1 A4 A1.0 3'-3 1/2" B-EM B-EM B-EM B-EM H H B-EM B-EM H 1'-10" B-EM 12" MIN 18" MIN 60" MIN 48" MIN 12" MIN 48" MIN 48" MIN 60" MIN 18" MIN 12" MIN Ø 60" MIN Ø 60" MIN 3'-0" A1
A1.1 A4 A1.1 NO.I HEREBY CERTIFY THAT THIS PLAN, DIRECT SUPERVISION AND THAT I AM PRELIMINARY UNDER THE LAWS IN THE STATE OF PREPARED BY ME OR UNDER MY REVISIONBY DATE DOCUMENT DATE
DRAWN BY DATE ISSUED FOR CHECKED BY SHEET TITLE REPORT, SPECIFICATION WAS PROJECT: LM PROJECT NO. SHEETS COVERED BY THIS SEAL: EXP. DATE REG.NO. A DULY REGISTERED ARCHITECT OWNER: A
S S O C I A T E SL T D CONCEPT BY: 10907 VALLEY VIEW ROAD EDEN PRAIRIE, MINNESOTA 55344 FAX 952-944-7585PHONE 952-944-7576 C 2020 L&M ASSOCIATES, LTD. ALL RIGHTS RESERVED FINAL
PERMIT 719 S. MEADOW ST. SUITE 1A ITHACA, NY 14850 23 DECEMBER 2020 MAESLEEP NUMBER 1001 3RD AVE. S. MINNEAPOLIS, MN 55404 2004.1070 NEW YORK ARCHITECTURAL 024169 30 JUNE 2023 SN STORE
#TBD 4/14/21 RMM A1.0 CODE COMPLIANCE PLANS A1 A4 SCALE: 1/4" = 1'-0" CODE COMPLIANCE PLAN SCALE 3/8" = 1'-0" ENLARGED CODE COMPLIANCE PLAN NORTH 2TENANT CHANGE4/13/21MAE 2
[005] A1.1.pdf
EXISTING PARTIALLY RECESSED PAPER TOWEL DISPENSERS, INSTALL PER MANUFACTURER'S INSTRUCTIONS, SEE DETAIL D4/A1.1 PROVIDE TOILET ROOM ACCESSIBILITY SIGNS SEE DETAIL B3/A1.1 EXISTING HORIZONTAL
RECESSED BABY CHANGING STATIONS, KOALA KARE KB100-05ST. INSTALL PER MANUFACTURER'S INSTRUCTIONS. SEE DETAIL B4/A1.1 30" MIN 48" MIN 48" MIN 30" MIN 60" MIN 56" MIN C D A B A1.1 D1 NO.I
HEREBY CERTIFY THAT THIS PLAN, DIRECT SUPERVISION AND THAT I AM PRELIMINARY UNDER THE LAWS IN THE STATE OF PREPARED BY ME OR UNDER MY REVISIONBY DATE DOCUMENT DATE DRAWN BY DATE ISSUED
FOR CHECKED BY SHEET TITLE REPORT, SPECIFICATION WAS PROJECT: LM PROJECT NO. SHEETS COVERED BY THIS SEAL: EXP. DATE REG.NO. A DULY REGISTERED ARCHITECT OWNER: A S S O C I A T E SL T
D CONCEPT BY: 10907 VALLEY VIEW ROAD EDEN PRAIRIE, MINNESOTA 55344 FAX 952-944-7585PHONE 952-944-7576 C 2020 L&M ASSOCIATES, LTD. ALL RIGHTS RESERVED FINAL PERMIT 719 S. MEADOW
ST. SUITE 1A ITHACA, NY 14850 23 DECEMBER 2020 MAESLEEP NUMBER 1001 3RD AVE. S. MINNEAPOLIS, MN 55404 2004.1070 NEW YORK ARCHITECTURAL 024169 30 JUNE 2023 SN STORE #TBD 4/14/21 RMM
A1.1 CODE COMPLIANCE PLANS & DETAILS A1 A3 A4 B3 B4 C1 D1 D4 27" MAX. TO BOTTOM OF WORK SURFACE 17"-25" TOE CLEARANCE 48" MAX. TO OPERABLE PORTION WALL ELEVATION SECTION SCALE: 1/2"
= 1'-0" BABY CHANGING STATION ACCESSIBILITY 34" MAX. TO HIGHEST PART OF WORK SURFACE 48" MAX. TO OPERABLE PORTION 48" MIN 30" MIN 30"x48" CLEAR FLOOR AREA CENTERED ON BABY CHANGING
STATION BABY CHANGING STATION SHALL COMPLY WITH MANEUVERING CLEARANCES AT DOORS WHEN IN DOWN OR OPEN POSITION MEETING REQUIREMENTS OF ICC/ANSI A117.1 SECTIONS 404. PROJECTIONS INTO
THE CLEAR OPENING WIDTH BETWEEN 34 INCHES AND 80 INCHES ABOVE THE FLOOR SHALL NOT EXCEED 4 INCHES. DOWN OR OPEN VIEW WALL PLAN SCALE 1/2" = 1'-0" ENLARGED TOILET ROOM PLAN EXIT TACTILE
EXIT SIGNS SHALL BE LOCATED AT EXIT DOORS PER IBC SECTION 1011.3. REQUIRED TEXT SHALL BE IN BOTH CHARACTERS AND BRAILLE, MEETING REQUIREMENTS OF ICC/ANSI A117.1 SECTIONS 703.3 & 703.4.
SIGNS SHALL BE MOUNTED BETWEEN 48" & 60" AFF PER ICC/ANSI A117.1 SECTION 703.3.10 AND ON THE LATCH SIDE OF THE DOOR WHERE POSSIBLE OR PER ICC/ANSI A117.1 SECTION 703.3.11. 48"-60" 3/8"
MIN EXIT GRADE 2 BRAILLE 5/8" TO 2" HIGH CHARACTERS, RAISED 1/32" MIN CONTRASTING, NON-GLARE FINISH ON BACKGROUND AND CHARACTERS. NOT TO SCALE TACTILE EXIT SIGN TOILET ROOM ACCESSIBILITY
SIGNS SHALL BE IDENTIFIED WITH THE INTERNATIONAL SYMBOL OF ACCESSIBILITY. SYMBOLS SHALL BE WITHIN 6 INCH HIGH MIN FIELD. REQUIRED TEXT SHALL BE IN BOTH CHARACTERS AND BRAILLE, MEETING
REQUIREMENTS OF ICC/ANSI A117.1 SECTIONS 703.3 & 703.4. TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE
OF THE LOWEST TACTILE CHARACTER AND 60 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST TACTILE CHARACTER. THE SIGNSHALL BE LOCATED
ALONGSIDE THE DOOR AT THE LATCH SIDE. NOT TO SCALE TOILET ROOM ACCESSIBILITY SIGNS 48" MIN. 60" MAX. C L 18" MIN 18" MIN SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED THAT A
CLEAR FLOOR SPACE OF 18 INCHES MIN. BY 18 INCHES MIN., CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN
POSITION. 45° 6" MIN 3/8" MIN" GRADE 2 BRAILLE 5/8" TO 2" HIGH CHARACTERS, RAISED 1/32" MIN CONTRASTING, NON-GLARE FINISH ON BACKGROUND AND CHARACTERS. RESTROOM RESTROOM RESTROOM 9"
MIN. 48" MAX. TO OPERABLE PORTION WALL ELEVATION SECTION SCALE: 1/2" = 1'-0" PAPER TOWEL DISPENSER ACCESSIBILITY 48" MAX. TO OPERABLE PORTION INSTALL PER MANUFACTURERS INSTRUCTIONS
48" 27" MIN 8" 30" ACCESSIBLE HI-LOW DRINKING FOUNTAIN 30"x48" CLEAR FLOOR AREA CENTERED ON LOW FOUNTAIN PLAN SECTION 38"-43" SPOUT 36" MAX SPOUT 6" MAX 9" MIN 17" MIN DEPTH 18"-19"
5" MAX C L SCALE: 1/2" = 1'-0" DRINKING FOUNTAIN ACCESSIBILITY 18" MIN MIRROR: BOBRICK B-290 2436 OR EQ. PAPER TOWEL DISPENSER: BOBRICK B-3944 OR EQ. SOAP DISPENSER: NOT REQUIRED.
HANDICAP LAVATORY: LEVER FAUCETS MUST BE PROVIDED. FAUCET CONTROLS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. FORCE REQUIRED
TO ACTIVATE THE CONTROLS SHALL BE NO GREATER THAN 5 LBS. HANDICAP GRAB BAR(S): BOBRICK B-6806 OR EQ. INSULATE 'P' TRAP AND SUPPLY LINES. TOILET PAPER HOLDER: BOBRICK B-685 OR EQ. DISPENSERS
SHALL NOT CONTROL DELIVERY OR PROHIBIT CONTINUOUS PAPER FLOW. HANDICAP TOILET: MOUNT CONTROLS ON OPEN ACCESSIBLE SIDE. ROBE HOOK: BOBRICK B-682; MOUNT ON BACK OF DOOR @ 48" AFF. BABY
CHANGING STATION: KOALA KARE KB100-05ST 1 2 3 4 5 6 7 8 A. GC SHALL FURNISH ALL ACCESSORIES, INCIDENTAL TRIM PIECES, ETC. FOR A COMPLETE INSTALLATION, INCLUDING BUT NOT LIMITED TO THE
FOLLOWING B. GC SHALL USE WATER RESISTANT DRYWALL FOR TOILET ROOMS AND FINISH TOILET ROOMS WITH MATERIALS ACCEPTABLE TO LOCAL CODE AUTHORITIES. C. GC SHALL PROVIDE BLOCKING IN WALLS
FOR GRAB BARS, MIRRORS, DISPENSERS, ETC. GRAB BARS SHALL BE LOCATED AS SHOWN. GRAB BARS, FASTENERS AND MOUNTING DEVICES SHALL WITHSTAND VERTICAL AND HORIZONTAL FORCES PER ANSI A117.1
SECTION 609.8. 9 10 SCALE: 3/8" = 1'-0" ILLUSTRATIVE TOILET ROOM ELEVATIONS SCALE: N/A TOILET ROOM NOTES ELEVATION 'A' 17-19" 42" MIN 12" MAX 18" MIN 39"-41" 39"-41" 5 8 7 52" FRP
WAINSCOT PT3 VB1 10 ELEVATION 'B' 33"-36" T/O GRIPPING SURFACE 12" MIN 40" MAX B/O REFLECTIVE SURFACE 15" MIN 16"-18" 17-19" 36" MIN 1 4 6 5 8 24"MIN 52" FRP WAINSCOT VB1 1 1/2" 1 1/4"Ø
1 1/2"Ø ELEVATION 'C' VB1 52" FRP WAINSCOT PT3 ELEVATION 'D' 1 4 2 VB11" 52" FRP WAINSCOT 9" MIN 6" MAX 8" MIN 11" MIN 34" MAX 40" MAX B/O REFLECTIVE SURFACE 27" MIN 33"-36" T/O GRIPPING
SURFACE 24" MIN 18" MIN 42" MAX 1 1/2" MIN 2 6 34" MAX 9 PT3PT3 C L C L
[006] A2.0.pdf
SCALE: 1/4" = 1'-0" FIXTURE PLAN NORTH QUEEN W/ HEADBOARD RACK PF1 SU SU SU SU SU SU SU VERIFY FLOOR BOX LOCATION FOR FIXTURE BED DIVIDER SU SU SU 41'-9 1/4" 69'-4 1/2" POS GRAPHIC
BANNERS BY TENANT ILLUMINATED 'OPEN' SIGN (4) WALL PANELS 37.5" X 108"H WALL MOUNTED NUMBERS TYPE (B) KINGKING KINGKING KINGQUEEN QUEEN 4'-9 1/4" QUEEN 3'-7 1/2"3'-7 1/2" SU SU SU SU
SU SU SU ABC 1 2 1'-1" EXISTING HI-LO DRINKING EXISTING UTILITY SINK STORAGE CABINET DESK AND SHELVES FILE CABINET REFRIGERATOR/ MICROWAVE EXISTING ELECTRICAL PANELS PRESSURE MAPPING
CABINET CLEAR FLOOR AREA FOR TEMP STORAGE 6'-9"6'-9"6'-5"13'-1 1/2"14'-3 5/8" A6.1 A3 101 SALES AREA 103 STORAGE 104 TOILET 105 DISPLAY 102 HALLWAY 4'-5 3/8"4'-10"11'-2 5/8" PROVIDE
BLOCKING PER A1/A2.1 11'-3" PROVIDE BLOCKING PER A1/A2.1 1'-5 1/2" EQEQ 11 1/2" 3'-2 1/4"C LC L C L C L C L C L 9 3/4" 6'-8 3/4" 1'-2 1/8" 15'-9 1/2" 15'-4 1/4" 15° 4'-5 1/4" C L B2
A2.1 C2 A2.1 3'-5"3'-6 1/2" 6'-8 1/2" WALL MTD CABINET 12 3 4 5 A6.0 C1 A6.0 C1 A6.0 A1 A6.0 A1 A7.0 C1 A6.1 C1 A6.1 C1 A6.1 A1 A6.1 A1 A7.0 A1 A7.1 C1 WALL MOUNTED NUMBERS (TYPE A),
SEE DETAIL D2/A2.1 A2.1 A2 B2 A2.1 B2 A2.1 FIXTURE PANEL NO.I HEREBY CERTIFY THAT THIS PLAN, DIRECT SUPERVISION AND THAT I AM PRELIMINARY UNDER THE LAWS IN THE STATE OF PREPARED BY
ME OR UNDER MY REVISIONBY DATE DOCUMENT DATE DRAWN BY DATE ISSUED FOR CHECKED BY SHEET TITLE REPORT, SPECIFICATION WAS PROJECT: LM PROJECT NO. SHEETS COVERED BY THIS SEAL: EXP. DATE
REG.NO. A DULY REGISTERED ARCHITECT OWNER: A S S O C I A T E SL T D CONCEPT BY: 10907 VALLEY VIEW ROAD EDEN PRAIRIE, MINNESOTA 55344 FAX 952-944-7585PHONE 952-944-7576 C 2020 L&M
ASSOCIATES, LTD. ALL RIGHTS RESERVED FINAL PERMIT 719 S. MEADOW ST. SUITE 1A ITHACA, NY 14850 23 DECEMBER 2020 MAESLEEP NUMBER 1001 3RD AVE. S. MINNEAPOLIS, MN 55404 2004.1070 NEW
YORK ARCHITECTURAL 024169 30 JUNE 2023 SN STORE #TBD 4/14/21 RMM A2.0 FIXTURE PLAN A1 1 2
[007] A2.1.pdf
SCALE: 1/4" = 1'-0" NUMBER DISCS DETAIL (TYPE A) 0'-0" AFF FINISH FLOOR WHITE DIMENSIONAL NUMBERS MOUNTED TO WALL, REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS PT4PAINT WALL: BENJAMIN
MOORE, 2063-10 OLD NAVY 10'-0" AFF B/O SOFFIT END OF WALL 8" 5'-3" 5" 5" 4'-9" 7'-4" 1'-2" 6'-2" NO.I HEREBY CERTIFY THAT THIS PLAN, DIRECT SUPERVISION AND THAT I AM PRELIMINARY UNDER
THE LAWS IN THE STATE OF PREPARED BY ME OR UNDER MY REVISIONBY DATE DOCUMENT DATE DRAWN BY DATE ISSUED FOR CHECKED BY SHEET TITLE REPORT, SPECIFICATION WAS PROJECT: LM PROJECT NO. SHEETS
COVERED BY THIS SEAL: EXP. DATE REG.NO. A DULY REGISTERED ARCHITECT OWNER: A S S O C I A T E SL T D CONCEPT BY: 10907 VALLEY VIEW ROAD EDEN PRAIRIE, MINNESOTA 55344 FAX 952-944-7585PHONE
952-944-7576 C 2020 L&M ASSOCIATES, LTD. ALL RIGHTS RESERVED FINAL PERMIT 719 S. MEADOW ST. SUITE 1A ITHACA, NY 14850 23 DECEMBER 2020 MAESLEEP NUMBER 1001 3RD AVE. S. MINNEAPOLIS,
MN 55404 2004.1070 NEW YORK ARCHITECTURAL 024169 30 JUNE 2023 SN STORE #TBD 4/14/21 RMM A2.1 PLAN DETAILS A1 A2 A3 A4 B2 B3 B4 C2 C3 C4 D2 D4 SCALE: FULL CARPET TO LVT TRANSITION NOTE:
GC TO ENSURE TRANSITION BETWEEN MATERIALS IS FLUSH AND CONTINUOUS. A DIFFERENCE GREATER THAN 1/4" WILL NOT BE ACCEPTED. TRANSITION STRIP TO BE UNDER DOOR AND NOT VISIBLE FROM SALES
AREA SIDE. GC SHALL PROVIDE CONCRETE - BASED FILLER PRODUCT TO ALLOW FOR SMOOTH TRANSITION HEIGHT, FOLLOW MANUFACTURERS' RECOMMENDATIONS GC SHALL PREPARE EXISTING FLOOR SLAB AS REQUIRED
FOR A SMOOTH TRANSITION. CARPET AND ADHESIVE 16GA ZINC FIN MTL TERRAZZO STRIP LVT TILE FLOORING 2 1 1/2" MAX NOTE: GC TO ENSURE TRANSITION BETWEEN MATERIALS IS FLUSH AND CONTINUOUS.
A DIFFERENCE GREATER THAN 1/2" WILL NOT BE ACCEPTED. THRESHOLD MUST HAVE A BEVELED TRANSITION WITH A SLOPE NOT GREATER THAN 1:2. COMPLY WITH ANSI & ADA SECTION 303.3 LUXURY VINYL TILE
EXISTING THRESHOLD, VIF GC SHALL PROVIDE CONCRETE-BASED FILLER PRODUCT TO ALLOW FOR SMOOTH TRANSITION. FOLLOW MANUFACTURERS' RECOMMENDATIONS EXISTING ENTRY DOOR, SEE DOOR SCHEDULE SCALE:
FULLSCALE LVT TO THRESHOLD TRANSITION 3/4" 4" WB1 MDF, PROVIDED BY FIXTURE MANUFACTURER, INSTALLED BY GC, PRIME ALL 4 SIDES AND PAINT EXPOSED SURFACES PT1 SCALE: 6"=1'-0" WOOD WALL
BASE DETAIL GYP BD AND STUD WALL PER PLAN NOTE: IN EXISTING WALL CONDITION, REMOVE REQUIRED AMOUNT OF GYP BD TO EXECUTE DETAIL. PROVIDE ADDITIONAL BLOCKING TO PATCH WALL FOR SMOOTH,
FLAT SURFACE TO ACCEPT NEW FINISH. MAINTAIN FIRE RATING WHERE APPLICABLE. SECTION 2X6 BLOCKING SCALE: 3"=1'-0" BED LAB BLOCKING DETAIL ELEVATION BLOCKING OPTIONS 2X6 OR 3 4"X6 (PLYWD)
FRT BLOCKING BETWEEN STUDS BEHIND GYP BD STUD TO STUD 3/4"X6" FRT PLYWOOD ONE END DADO INTO STUD FLANGE. 2X6 FRT BLOCKING, ONE END DADO INTO STUD FLANGE, OTHER END SCREWED THROUGH STUD
FACE INTO END OF BLOCKING 2- #10 2" EMBEDED AT NON-DADO END OF FRT PLYWD BLOCKING. SECTION PLYWOOD BLOCKING CNT LN OF BLOCKING, SEE FIXTURE ELEVATIONS FOR LOCATION (THREE HORIZ RUNS;
27"AFF, 67"AFF, 108") PLAN BLOCKING BOTH OPTIONS FRT BLOCKING ONE END DADO INTO STUD FLANGE, SEE PLAN VIEW BELOW FRT BLOCKING ONE END ANCORED WITH SCREWS INTO BLOCKING THROUGH STUD
FACE LINE OF 3 4" PLYWD BLOCKING OPTION DADO FRT BLOCKING, ONE END DADO INTO STUD FLANGE, OTHER END SCREWED THROUGH STUD FACE INTO END OF BLOCKING NON- DADO END FRT BLOCKING 2-#10 2"
EMBEDED SCREW INTO BLOCKING END THROUGH STUD FACE CNT LN OF BLOCKING, SEE FIXTURE ELEVATIONS FOR LOCATION (THREE HORIZ RUNS; 27"AFF, 67"AFF, 108") CNT LN OF BLOCKING, SEE FIXTURE ELEVATIONS
FOR LOCATION (THREE HORIZ RUNS; 27"AFF, 67"AFF, 108") SECURE ONE STORAGE UNIT WITHIN EACH GROUPING TO WALL VIA 2"x4" WD BLOCKING. ATTACH BLOCKING TO WALL W/ MIN (1) #10 STEEL SELF-TAPPING
SCREW, MIN 3/4" EMBED INTO STUD, & TO UNIT W/ (2) #8 WD SCREWS, MIN 3/4" EMBED INTO BLOCKING. SCALE: 1/2" = 1'-0" (SU) ANCHOR - BACK WALL PARTITION PER WALL SCHEDULE. SECURE STORAGE
UNITS TO ONE ANOTHER W/ (2) #8 WD SCREWS, MIN 1/2" EMBED. FRONT VIEW ADJUSTABLE SHELF TO BE INSTALLED AFTER UNITS ARE FULLY ASSEMBLED AND ANCHORED. 7'-10" SIDE VIEW 12" 1" 5/8" TYPE
'X' GYP BD ON 3 5/8" 20 GA MTL STUD FRAMING AT 16"OC EZ ANCOR CLG 'TOGGLE LOCK', AT 24"OC MAX (50 LBS MAX WEIGHT CAPACITY EACH) TENANT PROVIDED WIRE GRID HANGER BOLTS SUPPLIED BY FM,
INSTALLED BY GC. SCALE: 3"=1'-0" DISPLAY GRID DETAIL 2 1 1/2" MAX NOTE: GC TO ENSURE TRANSITION BETWEEN MATERIALS IS FLUSH AND CONTINUOUS. A DIFFERENCE GREATER THAN 1/2" WILL NOT BE
ACCEPTED. THRESHOLD MUST HAVE A BEVELED TRANSITION WITH A SLOPE NOT GREATER THAN 1:2. COMPLY WITH ANSI & ADA SECTION 303.3 EXISTING THRESHOLD, VIF EXISTING ENTRY DOOR, SEE DOOR SCHEDULE
SCALE: FULLSCALE CARPET TO THRESHOLD TRANSITION GC SHALL PROVIDE CONCRETE - BASED FILLER PRODUCT TO ALLOW FOR SMOOTH TRANSITION HEIGHT, FOLLOW MANUFACTURERS' RECOMMENDATIONS CARPET
AND ADHESIVE SCALE: NTS NOT USED ANCHOR STORAGE UNIT BASE TO EXISTING CONCRETE SLAB W/ (2) 3/8"Ø EXPANSION ANCHORS PER UNIT @ 12" OC, EMBEDDED 2" MIN. HILTI KWIK BOLT 3 OR EQ. SECURE
STORAGE UNITS TOGETHER FROM ABOVE. ATTACH 1"x6" WD BLOCKING TO EACH UNIT W/ (2) #8x1 1/4" WD SCREWS. GC SHALL PROVIDE AND INSTALL CONTINUOUS 1/2" MDF BACKING ON STORAGE UNITS FOR RIGIDITY.
ANCHOR UNITS TO EACH OTHER THROUGH SIDES AND BACKING 12" FROM TOP AND BOTTOM OF UNIT W/ (2) #10 STEEL SELF-TAPPING SCREWS, EMBEDDED 3/4" MIN. SCALE: 3/4" = 1'-0" SU-FREE STANDING ANCHOR
12" EXISTING CONCRETE SLAB 12" ELEVATION ℄ FIXTURE/BED ℄ AS INDICATED ON ARCHITECTURAL FLOOR PLAN 120 V DUPLEX BLACK COVER PLATE AND DEVICE 2" DIA GROMMET FOR 1-1/2" CONDUIT FOR VGA
CONNECTION, PAINT TO MATCH WALL COLOR OPENING FOR CORD ACCESS SCALE: 1/2" = 1'-0" ILLUST I-FIT WALL DTLS AND CONNECTIONS 1'-4" 11"1'-4" 1'-6" EQ EQ THIS DETAIL INSTALLED AT INVERTED
BOX IN CLG 1'-0" CARPET AND ADHESIVE ARMSTONG VINYL TRANSITION CONCRETE GC SHALL PROVIDE CONCRETE-BASED FILLER PRODUCT TO ALLOW FOR SMOOTH TRANSITION, FOLLOW MANUFACTURERS' RECOMMENDATIONS
NOTE: GC TO ENSURE TRANSITION BETWEEN MATERIALS IS FLUSH AND CONTINUOUS. A DIFFERENCE GREATER THAN 1/4" WILL NOT BE ACCEPTED. TRANSITION STRIP TO BE UNDER DOOR AND NOT VISIBLE FROM
SALES AREA SIDE WHERE APPLICABLE. 1/4" MAX SCALE: FULL SCALE CARPET TO CONCRETE TRANSITION 1
[008] A3.0.pdf
SCALE: 1/4" = 1'-0" REFLECTED CEILING PLAN NORTH ABC 1 2 B T A A A T A A A A A T A A A A A P P B B-NL T A A A A A T A B-NL B CF CF CF CF CF CF CF CF CF CFCFCFCFCFCFCFCFCFCFCFCF B-NLB
B B B B B B B B BB B B BB B-EM B-EM B-EM B-EM BB S S S S J J UNISTRUT ANCHORED TO STRUCTURAL MEMBERS ABOVE BY LANDLORD, SEE DETAIL F8 H F8 F8 F8 J H B-EM B-EM B B-NL J B2 S 12'-0" AFF
VIF ACT GRIDAT2 10'-0" AFF VIF ACT GRIDAT1 12'-0" AFF VIF ACT GRID 8'-0" AFF VIF EXIST GYP BD CEILING 10'-0" AFF VIF EXISTING GYP BD SOFFIT PT1 PT1 10'-0" AFF VIF EXISTING GYP BD SOFFIT
PT1 10'-0" AFF VIF EXISTING GYP BD SOFFIT PT1 SPEAKER, TYP OF (4) 9'-11" AFF DISPLAY GRID, TYP A3 A2.1 AT1 B 9'-11" AFF DISPLAY GRID, TYP A3 A2.1 J J-BOX FOR EXTERIOR SIGNAGE ABOVE
SOFFIT J J-BOX FOR EXTERIOR SIGNAGE ABOVE SOFFIT WI-FI ARCH CANOPY A3 A6.1 H B-EM NO.I HEREBY CERTIFY THAT THIS PLAN, DIRECT SUPERVISION AND THAT I AM PRELIMINARY UNDER THE LAWS IN
THE STATE OF PREPARED BY ME OR UNDER MY REVISIONBY DATE DOCUMENT DATE DRAWN BY DATE ISSUED FOR CHECKED BY SHEET TITLE REPORT, SPECIFICATION WAS PROJECT: LM PROJECT NO. SHEETS COVERED
BY THIS SEAL: EXP. DATE REG.NO. A DULY REGISTERED ARCHITECT OWNER: A S S O C I A T E SL T D CONCEPT BY: 10907 VALLEY VIEW ROAD EDEN PRAIRIE, MINNESOTA 55344 FAX 952-944-7585PHONE
952-944-7576 C 2020 L&M ASSOCIATES, LTD. ALL RIGHTS RESERVED FINAL PERMIT 719 S. MEADOW ST. SUITE 1A ITHACA, NY 14850 23 DECEMBER 2020 MAESLEEP NUMBER 1001 3RD AVE. S. MINNEAPOLIS,
MN 55404 2004.1070 NEW YORK ARCHITECTURAL 024169 30 JUNE 2023 SN STORE #TBD 4/14/21 RMM A3.0 REFLECTED CEILING PLAN A1 GENERAL CEILING NOTES 1. VERIFY THAT THERE ARE NO OBSTRUCTIONS
THAT WILL IMPEDE THE DESIRED CEILING HEIGHT 2. LAYOUT CEILING GRID AND TILE AS SHOWN ON THIS PLAN 3. B, B-EM, B-NL AND P TYPE LIGHT FIXTURES (UNLESS INDICATED OTHERWISE GRAPHICALLY)
AND SPEAKERS ARE TO BE LOCATED IN THE CENTER OF THE 2X2 CEILING TILE 4. FIXTURES NOT SHOWN CENTERED IN CEILING TILE SHALL BE LOCATED 6" FROM CENTER IN THE NORTH-SOUTH DIRECTION AND/OR
6" FROM CENTER IN THE EAST-WEST DIRECTION, AS SHOWN GRAPHICALLY ON RCP. 5. LIGHT FIXTURE TRACKS 'T' AT WALL FIXTURES TO BE CENTERED ON FIXTURES. SEE SHEET A3.1 FOR DIMENSIONS TO CENTER
OF TRACKS. 6. FIXTURE CANOPIES TO BE INSTALLED PER INSTRUCTIONS AND WITH HARDWARE FROM FM. 7. GYPSUM BOARD SOFFITS TO BE BACKED ENTIRELY BY PLYWOOD SUBSTRATE. 8. FIXTURES AT STOREFRONT
WINDOWS TO BE CENTERED ON EACH GLAZING PANE AS CLOSE TO GLAZING AS POSSIBLE OR AS DIMENSIONED. 2TENANT CHANGE4/13/21MAE 2
[009] A4.0.pdf
SCALE: 1/4" = 1'-0" FINISH FLOOR PLAN NORTH WB1 PT1 PT1 PT1 101 SALES AREA AT1 DOORS/JAMBS CEILING WALLS SOFFITS BASE DETAIL C3/A2.1 FC2 FLOOR TILE PATTERN DIRECTION 105 DISPLAY CEILING
FC2 WB1 PT4 PT4 PT1 DOORS/JAMBS WALLS FLOOR BASE DETAIL C3/A2.1 WB1 PT1 ALL SIDES 13'-6" EXTENTS OF WC1 C3 A2.1 TYP 20'-6 5/8" EXTENTS OF PT4 12'-8 1/2" EXTENTS OF PT4 7'-3" EXTENTS
OF PT4 103 STORAGE CS1 VB1 PT1 AT2 PT1 DOORS/JAMBS BASE FLOOR CEILING WALLS FC1 VB1 FRP PT1 PT1 PT3 DOORS/JAMBS WALLS BASE FLOOR CEILING WALLS 104 TOILET 102 HALLWAY CEILING FC2 WB1
PT1 PT1 AT1 DOORS/JAMBS WALLS FLOOR BASE DETAIL C3/A2.1 FC2 A4 A2.1 C4 A2.1 B4 A2.1 D4 A2.1 13'-9 3/8" VIF 5'-0" FC1 FLOOR FC2 B4 A2.1 FRP WALLS (UTILITY SINK) NO.I HEREBY CERTIFY THAT
THIS PLAN, DIRECT SUPERVISION AND THAT I AM PRELIMINARY UNDER THE LAWS IN THE STATE OF PREPARED BY ME OR UNDER MY REVISIONBY DATE DOCUMENT DATE DRAWN BY DATE ISSUED FOR CHECKED BY SHEET
TITLE REPORT, SPECIFICATION WAS PROJECT: LM PROJECT NO. SHEETS COVERED BY THIS SEAL: EXP. DATE REG.NO. A DULY REGISTERED ARCHITECT OWNER: A S S O C I A T E SL T D CONCEPT BY: 10907
VALLEY VIEW ROAD EDEN PRAIRIE, MINNESOTA 55344 FAX 952-944-7585PHONE 952-944-7576 C 2020 L&M ASSOCIATES, LTD. ALL RIGHTS RESERVED FINAL PERMIT 719 S. MEADOW ST. SUITE 1A ITHACA,
NY 14850 23 DECEMBER 2020 MAESLEEP NUMBER 1001 3RD AVE. S. MINNEAPOLIS, MN 55404 2004.1070 NEW YORK ARCHITECTURAL 024169 30 JUNE 2023 SN STORE #TBD 4/14/21 RMM A4.0 ROOM FINISH PLAN
A1 2CORRECTION4/13/21MAE 2
[010] A6.0.pdf
SCALE: 1/4" = 1'-0" INTERIOR SECTION/ELEVATION CA B WB1 C3 A2.1 WB1 TYP 0'-0" AFF FINISH FLOOR 23'-6" AFF, VIF T/O PARAPET 20'-2" AFF VIF B/O SLOPED ROOF DECK 12'-0" AFF VIF ACT 10'-0"
AFF VIF B/O SOFFIT 9'-10 1/2" AFF VIF T/O STOREFRONT 0'-0" AFF FINISH FLOOR 23'-6" AFF, VIF T/O PARAPET 21'-0" AFF VIF B/O SLOPED ROOF DECK 10'-0" AFF VIF ACT AT1PT1 AT1PT1 PT4 SOFFIT
& FASCIA WB1 WB1 FIXTURE NOT SHOWN FOR WALL FINISH CLARITY PT1 PT1 7'-0" AFF VIF T/O DOOR 9'-10 1/2" AFF VIF T/O STOREFRONT PT1 ALL SIDES OF COLUMN C A B SCALE: 1/4" = 1'-0" INTERIOR
SECTION/ELEVATION SCALE: 1/4" = 1'-0" 0'-0" AFF FINISH FLOOR 23'-6" AFF, VIF T/O PARAPET 20'-2" AFF VIF B/O SLOPED ROOF DECK 12'-0" AFF VIF ACT 9'-10 1/2" AFF VIF T/O STOREFRONT 10'-0"
AFF VIF B/O SOFFIT VB1 AT2PT1 WB1 C3 A2.1 WB1WB1 TYP AT1 WC1PT1 PT1PT4 PT1 6" 9'-0" 6" 12'-6" (4) WC1 PANELS ANGLED WALL WB1 0'-0" AFF FINISH FLOOR 23'-6" AFF, VIF T/O PARAPET 21'-0"
AFF VIF B/O SLOPED ROOF DECK 8'-0" AFF VIF ACT PT1 A3 A6.1 SYM/OPP NO.I HEREBY CERTIFY THAT THIS PLAN, DIRECT SUPERVISION AND THAT I AM PRELIMINARY UNDER THE LAWS IN THE STATE OF PREPARED
BY ME OR UNDER MY REVISIONBY DATE DOCUMENT DATE DRAWN BY DATE ISSUED FOR CHECKED BY SHEET TITLE REPORT, SPECIFICATION WAS PROJECT: LM PROJECT NO. SHEETS COVERED BY THIS SEAL: EXP. DATE
REG.NO. A DULY REGISTERED ARCHITECT OWNER: A S S O C I A T E SL T D CONCEPT BY: 10907 VALLEY VIEW ROAD EDEN PRAIRIE, MINNESOTA 55344 FAX 952-944-7585PHONE 952-944-7576 C 2020 L&M
ASSOCIATES, LTD. ALL RIGHTS RESERVED FINAL PERMIT 719 S. MEADOW ST. SUITE 1A ITHACA, NY 14850 23 DECEMBER 2020 MAESLEEP NUMBER 1001 3RD AVE. S. MINNEAPOLIS, MN 55404 2004.1070 NEW
YORK ARCHITECTURAL 024169 30 JUNE 2023 SN STORE #TBD 4/14/21 RMM A6.0 INTERIOR SECTIONS & ELEVATIONS A1 C1 1 1
[011] A6.1.pdf
SCALE: 1/4" = 1'-0" INTERIOR SECTION/ELEVATION SCALE: 1/4" = 1'-0" 1 2 WB1 0'-0" AFF FINISH FLOOR 23'-6" AFF, VIF T/O PARAPET 20'-8" AFF VIF B/O SLOPED ROOF DECK AT SECTION 12'-0"
AFF VIF ACT 10'-0" AFF VIF B/O SOFFIT 9'-10 1/2" AFF VIF T/O STOREFRONT OPEN TO HALLWAY WB1WB1 PT4 PT4 ANGLED WALL AT1 PT1PT4 1'-6" WALL MOUNTED VINYL NUMBERS A3 A6.1 4" 3'-1" 3'-6"
5'-3" 2'-11"5'-3" 4'-4" C3 A2.1 TYP 12 SCALE: 1/4" = 1'-0" INTERIOR SECTION/ELEVATION 0'-0" AFF FINISH FLOOR 23'-6" AFF, VIF T/O PARAPET 20'-2" AFF VIF B/O SLOPED ROOF DECK AT SECTION
12'-0" AFF VIF ACT 10'-0" AFF VIF B/O SOFFIT 9'-10 1/2" AFF VIF T/O STOREFRONT C3 A2.1 TYP WB1 AT1PT1 6'-0" ILLUMINATED 'OPEN' SIGN BY TENANT GRAPHIC BANNERS BY TENANT 1'-8" 3'-4" 3'-8"
PT1 SOFFIT & FASCIA PT1 SCALE: 1/2" = 1'-0" PANEL CANOPY SECTION PERPENDICULAR TO 45 DEG WALL 0'-0" AFF FINISH FLOOR 12'-0" AFF CEILING 6'-7" RUN 1 1/2" CONDUIT W/ PULL STRING TO J-BOX
AT MONITOR BOX FOR ELECTRICAL/DATA FOR EACH CEILING MONITOR, SEE ELECTRICAL SHEETS 8'-6" B/O MOUNTING PLATE 4 3/4" 7'-1" BOTTOM REAR EDGE OF CANOPY SCALE: 1/2" = 1'-0" A2.1 A2 9'-0"
BOTTOM FRONT EDGE OF CANOPY C3 A6.1 SCALE: 1/2" = 1'-0" PANEL CANOPY SUPPORT FRAMING MONITOR MAST CANOPY PANEL SYSTEM BY SN VENDOR DEMISING WALL 12"x12"FRT BLOCKING FOR PENDANT MOUNT
ROOF DECK ABOVE AND TRUSSES UNISTRUT SPANS MIN TWO ROOF TRUSS (VIF LOCATION/DIRECTION). SEE DTL C1/A2.1 ANCHOR OPTIONS. LATERAL BRACE UNISTRUT TO WALL STUDS AT 45° AND DEMISING WALLS
45° WALL UNISTRUT, AT 45° TO ROOF TRUSSES. SEE DETAIL A2/A2.1 1/4"DIA PENDANTS ALLTHREAD (4 TOTAL) 12'-0" AFF CEILING 20'-8" AFF VIF B/O SLOPED ROOF DECK NO.I HEREBY CERTIFY THAT THIS
PLAN, DIRECT SUPERVISION AND THAT I AM PRELIMINARY UNDER THE LAWS IN THE STATE OF PREPARED BY ME OR UNDER MY REVISIONBY DATE DOCUMENT DATE DRAWN BY DATE ISSUED FOR CHECKED BY SHEET
TITLE REPORT, SPECIFICATION WAS PROJECT: LM PROJECT NO. SHEETS COVERED BY THIS SEAL: EXP. DATE REG.NO. A DULY REGISTERED ARCHITECT OWNER: A S S O C I A T E SL T D CONCEPT BY: 10907
VALLEY VIEW ROAD EDEN PRAIRIE, MINNESOTA 55344 FAX 952-944-7585PHONE 952-944-7576 C 2020 L&M ASSOCIATES, LTD. ALL RIGHTS RESERVED FINAL PERMIT 719 S. MEADOW ST. SUITE 1A ITHACA,
NY 14850 23 DECEMBER 2020 MAESLEEP NUMBER 1001 3RD AVE. S. MINNEAPOLIS, MN 55404 2004.1070 NEW YORK ARCHITECTURAL 024169 30 JUNE 2023 SN STORE #TBD 4/14/21 RMM A6.1 INTERIOR SECTIONS,
& ELEVATIONS A1 A3 C1 C3 1 1
[012] A7.0.pdf
SCALE: 1/4" = 1'-0" EXTERIOR ELEVATION - SOUTH SIGNAGE BY OTHERS UNDER SEPARATE REVIEW & PERMIT 0'-0" AFF FINISH FLOOR 7'-0" AFF VIF ENTRY DOORS 10'-0" AFF VIF STOREFRONT GLAZING 23'-6"
AFF VIF PARAPET ILLUMINATED 'OPEN' SIGN BY TENANT 20'-6" AFF VIF ROOF LINE EXISTING AWNINGS 1 2 FEDEX OFFICE SLEEP NUMBER GRAPHIC BANNERS BEYOND GLAZING BY TENANT ROOF LINE EXISTING
AWNING SCALE: 1/4" = 1'-0" EXTERIOR ELEVATION - WEST SCALE: 1/4" = 1'-0" SIGNAGE BY OTHERS UNDER SEPARATE REVIEW & PERMIT 0'-0" AFF FINISH FLOOR 10'-0" AFF VIF STOREFRONT GLAZING
23'-6" AFF VIF PARAPET 20'-6" AFF VIF ROOF LINE EXISTING AWNINGS WALL MOUNTED NUMBERS (TYPE A) BEYOND GLAZING; SEE DETAIL D2/A2.1 EXISTING AWNINGS C B A ROOF LINE NO.I HEREBY CERTIFY
THAT THIS PLAN, DIRECT SUPERVISION AND THAT I AM PRELIMINARY UNDER THE LAWS IN THE STATE OF PREPARED BY ME OR UNDER MY REVISIONBY DATE DOCUMENT DATE DRAWN BY DATE ISSUED FOR CHECKED
BY SHEET TITLE REPORT, SPECIFICATION WAS PROJECT: LM PROJECT NO. SHEETS COVERED BY THIS SEAL: EXP. DATE REG.NO. A DULY REGISTERED ARCHITECT OWNER: A S S O C I A T E SL T D CONCEPT BY:
10907 VALLEY VIEW ROAD EDEN PRAIRIE, MINNESOTA 55344 FAX 952-944-7585PHONE 952-944-7576 C 2020 L&M ASSOCIATES, LTD. ALL RIGHTS RESERVED FINAL PERMIT 719 S. MEADOW ST. SUITE 1A
ITHACA, NY 14850 23 DECEMBER 2020 MAESLEEP NUMBER 1001 3RD AVE. S. MINNEAPOLIS, MN 55404 2004.1070 NEW YORK ARCHITECTURAL 024169 30 JUNE 2023 SN STORE #TBD 4/14/21 RMM A7.0 EXTERIOR
ELEVATIONS A1 C1
[013] A7.1.pdf
SCALE: 1/4" = 1'-0" EXTERIOR ELEVATION - NORTH EXISTING AWNING ROOF LINE FEDEX OFFICE SLEEP NUMBER 2 1 0'-0" AFF FINISH FLOOR 10'-0" AFF VIF STOREFRONT GLAZING 23'-6" AFF VIF PARAPET
NO.I HEREBY CERTIFY THAT THIS PLAN, DIRECT SUPERVISION AND THAT I AM PRELIMINARY UNDER THE LAWS IN THE STATE OF PREPARED BY ME OR UNDER MY REVISIONBY DATE DOCUMENT DATE DRAWN BY DATE
ISSUED FOR CHECKED BY SHEET TITLE REPORT, SPECIFICATION WAS PROJECT: LM PROJECT NO. SHEETS COVERED BY THIS SEAL: EXP. DATE REG.NO. A DULY REGISTERED ARCHITECT OWNER: A S S O C I A T
E SL T D CONCEPT BY: 10907 VALLEY VIEW ROAD EDEN PRAIRIE, MINNESOTA 55344 FAX 952-944-7585PHONE 952-944-7576 C 2020 L&M ASSOCIATES, LTD. ALL RIGHTS RESERVED FINAL PERMIT 719
S. MEADOW ST. SUITE 1A ITHACA, NY 14850 23 DECEMBER 2020 MAESLEEP NUMBER 1001 3RD AVE. S. MINNEAPOLIS, MN 55404 2004.1070 NEW YORK ARCHITECTURAL 024169 30 JUNE 2023 SN STORE #TBD 4/14/21
RMM A7.1 EXTERIOR ELEVATIONS C1
Specifications/[001] Letter of_mittal - 534230.pdf
State Permits Inc. 319 Elaines Court - Dodgeville, WI 53533 415-PERMITS - www.permit.com Letter of Transmittal Project #: 942798 Date: 04/20/2021 8:47am Store: Sleep Number #: Ithaca
Address: 719 South Meadow Street #1A Ithaca, NY, 14850 From: To: Erika Aultman 319 Elaines Court Dodgeville WI 53533 (608) 407-9082 - erika@permit.com Phyllis Radke Ithaca Building
Dept 108 East Green St Ithaca, NY 14850 (607) 274-6508 Transmitting Via: Items: 1 set of plans 1 PDf set of plans These Are Transmitted: Plans Remarks: For review to go with application
submitted online for review. Any questions contact Erika Aultman at erika@permit.com or 608-407-9082 Signature: Erika Aultman - (608) 407-9082 - erika@permit.com 415-PERMITS • www.permit.com