Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Addendum No. 1_6-11-2021_Corson Hall Rm E136-E142A Lab Renovation
CORNELL UNIVERSITY CORSON HALL RM E136-E142A FACILITIES CONTRACTS LAB RENOVATION 121 HUMPHREYS SERVICE BUILDING ITHACA, NEW YORK 14853-3701 ADDENDUM NO. 1 June 11, 2021 This Addendum contains changes to the requirements of the Contract Documents and Specifications. Such changes are to be incorporated into the Construction Documents and shall apply to the work with the same meaning and force as if they had been included in the original document. Wherever this Addendum modifies a portion of a paragraph of the specifications or a portion of any Drawing, the remainder of the Paragraph or Drawing shall remain in force. NOTE: Provisions of all Contract Documents apply. Item 1. Drawing Sheet P-000R. DELETE in its entirety. REPLACE with revised sheet P-000, attached. Item 2. Drawing Sheet P-100R. DELETE in its entirety. REPLACE with revised drawing P-100, attached. Item 3. RFI Questions and Clarifications. See attached RFI Log (Item 1-4) Attachments: P-000R P-100R RFI Log (Items 1-4) ****END OF ADDENDUM**** WALL HYDRANT (WH) / HOSE BIBB (HB) SHOCK ABSORBER (SA) BACKFLOW PREVENTER (BFP) UNION PRESSURE REDUCING VALVE CHECK VALVE BALANCING VALVE SHUT OFF VALVE INDIRECT WASTE PIPING (IW)IW FLOOR DRAIN (FD) / FLOOR SINK (FS) CLEANOUT (CO) WALL PLATE CLEANOUT (WPCO) DECK PLATE CLEANOUT (DPCO) CAP OR PLUG PIPE CONTINUATION "P" TRAP TOP TEE CONNECTION BOTTOM/TEE CONNECTION ELBOW UP 45°OFFSET ELBOW DOWN DESCRIPTION PLUMBING SYMBOL LIST SYMBOL VACUUM PIPING (V)V COMPRESSED AIR PIPING (CA)CA NATURAL GAS PIPING (G)G LAB VENT PIPING (LV)LV STRAINER LAB WASTE PIPING (LW)LW DIR DEIONIZED WATER RETURN PIPING (DIR) DEIONIZED WATER PIPING (DI)DI TEMPERED HOT WATER RETURN PIPING (TWR)TWR TEMPERED HOT WATER PIPING (TW)TW HOT WATER RECIRCULATING PIPING (HWR) HOT WATER PIPING (HW) COLD WATER PIPING (CW) NEW PIPING LOCATED BELOW FLOOR/SLAB NEW PIPING LOCATED ABOVE FLOOR/SLAB (E)EXISTING PIPING EC ELECTRICAL CONTRACTOR PC PLUMBING CONTRACTOR MC MECHANICAL CONTRACTOR GC GENERAL CONTRACTOR VTR VENT THRU ROOF BFF BELOW FINISHED FLOOR AFF ABOVE FINISHED FLOOR (ETR)EXISTING TO REMAIN (E)EXISTING NTS NOT TO SCALE POINT OF DISCONNECTION POINT OF CONNECTION EXISTING WORK TO BE REMOVED DRAWING KEYNOTE DEMOLITION/REMOVAL KEYNOTE X X GO GAS OUTLET 1 DETAIL NOTES: DOMESTIC COLD WATER FLOW DIRECTION LABEL. PROVIDE 360 DEGREE WRAP OVERLAPPING BOTH ENDS OF THE PIPE FUNCTION LABEL AND MATCHING THE FLOW DIRECTION OF THE PIPE CONTENTS. PIPE FUNCTION LABEL A. B. C. D. E. F. PROVIDE A PIPE LABEL FOR EACH PIPE FUNCTION. PROVIDE AT LEAST ONE LABEL ON EACH PIPE FOR EVERY ROOM THE PIPE PASSES THROUGH. PROVIDE LABELS IN LARGE SPACES ON MAXIMUM 20' CENTERS FOR EVERY PIPE UNLESS OTHERWISE NOTED IN THE SPECIFICATIONS. LABELS TO BE LOCATED IN AN EASILY VISIBLE LOCATION AS THEY WOULD NORMALLY BE SEEN. IE. ON THE BOTTOM HALF OF PIPES IN THE AIR AND ON THE TOP HALF OR SIDES OF PIPES MOUNTED LOW. LABELS SHALL BE, COLOR CODED, PRE-PRINTED, SELF ADHESIVE VINYL. SEE SPECIFICATION FOR OTHER REQUIREMENTS AND LIST OF PIPE FUNCTIONS. DETAIL NOTES: (E)FUME HOOD WORK SURFACE AT NON ADA HEIGHT, 36 INCHES ABOVE FINISHED FLOOR. (E)FUME HOOD WORK SURFACE AT ADA HEIGHT, 30 INCHES ABOVE FINISHED FLOOR. PROVIDE 2" DRUM TRAP. PROVIDE SUFFICIENT PIPE ON INLET TO ALLOW 6" OF WORK SURFACE ADJUSTMENT. PROVIDE 1 1/2" DRAIN FROM CUP SINK. PROVIDE SUFFICIENT TAILPIECE ON OUTLET TO ALLOW FOR 6" OF WORK SURFACE ADJUSTMENT. DRAIN IS TO BE SLEEVED WITHIN THE 2" INLET PIPE PROVIDED ON THE DRUM TRAP. 2" DRAIN, ROUTE BEHIND UNIT IN CHASE SPACE AND CONNECT TO SINK DRAIN PROVIDE 1 1/2" ACID VENT SERVING CUP SINK DRAIN. CONNECT TO NEAREST VENT SERVICE AS INDICATED ON PLANS. COORDINATE WITH VENT FROM ADJACENT LABORATORY FIXTURES. DOMESTIC COLD WATER CONNECTION: PROVIDE BRASS/ STAINLESS STEEL FLEXIBLE CONNECTION TO PRE-PIPED LABORATORY DOMESTIC WATER SERVICE AT FT FUME HOOD. GAS CONNECTION: PROVIDE BRASS/ STAINLESS STEEL FLEXIBLE CONNECTION TO PRE-PIPED LABORATORY DOMESTIC WATER SERVICE AT FT FUME HOOD. 1 2 3 4 5 6 7 LAB EXHAUST DUCT (TYP.) DUCT COLLAR (TYP.) FUME HOOD FUME HOOD 1 7 2 7 4 3 5 6 4 3 5 6 8 8 8 GAS SOLENOID VALVESTRAINER GAS SHUTOFF VALVE S MASTER GAS SHUTOFF VALVE SWITCH RELAY CONTROL PANEL BRANCH LINE SIZE AS INDICATED ON DRAWING. A. DETAIL NOTES: DIVISION 22 SHALL PROVIDE ALL CONTROL WIRING BETWEEN SWITCH, RELAY PANEL AND GAS SHUTOFF VALVE(S). POWER WIRING TO THE RELAY PANEL WILL BE BY DIVISION 26. VALVES ARE SHOWN FOR CLARITY ONLY. REFER TO PLANS FOR LOCATIONS. B. POWER WIRING TO PANEL BY DIVISION 26. COORDINATE INSTALLATION WITH DIVISION 26. (E)3/4"(E)3/4" EMERGANCY EYEWASH. LOCATE SO WHEN IN USE IT IS OVER THE SINK. 2" LAB WASTE. PIPING IN WALL. SINK TMV. REFER TO ASSOCIATED EYEWASH SPECIFICATION FOR TYPE.1/2" COLD WATER SUPPLY 1/2" HOT WATER SUPPLY 1/2" RODI WATER SUPPLY LAB VENT. REFER TO PLANS TO SEE IF INDIVIDUAL VENT IS REQUIRED. DI FAUCET PIPING IN WALL (TYP) NOTE: IF IN ADA CABINET, ALL PIPING SHALL MEET ANSI & ADA REQUIREMENTS FINISHED FLOOR CASEWORK These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions6/11/2021 10:48:22 AMC:\Users\cmdoktor\Documents\200311_CorsonFirstFloor_P_Central_R20_cmdoktor.rvt20625.01 THK General Notes, Symbols List, Details & Schedules - Plumbing GDD CMD P-000R 100% Construction Documents Submission Cornell University Corson Hall Rm 136-142A Lab Renovation Ithaca, NY May 7, 2021 NOT TO SCALE1PIPING IDENTIFICATION LABEL DETAIL NOT TO SCALE3ADJUSTABLE FUME HOOD INSTALLATION DETAIL THESE NOTES ARE APPLICABLE TO THE FULL SET OF CONTRACT DOCUMENTS. EXISTING CONDITIONS ARE TAKEN FROM FIELD OBSERVATIONS AND PRIOR CONSTRUCTION DOCUMENTS WHEN AVAILABLE. THE LOCATIONS SHOWN MUST BE CONSIDERED APPROXIMATE. OTHER SUCH WORK MAY EXIST, HOWEVER, LOCATION AND SIZE ARE NOT PRESENTLY KNOWN. IT IS STRONGLY ENCOURAGED TO VISIT SITE PRIOR TO BID TO REVIEW EXISTING CONDITIONS AND CONFIRM SCOPE OF WORK. WHEN EXISTING CONSTRUCTION IS DAMAGED DURING WORK BY THIS CONTRACTOR, REPAIR AND/OR REPLACE WITH SIMILAR MATERIALS AS MUCH AS POSSIBLE, SUBJECT TO ARCHITECTS APPROVAL. DISPOSE OF ALL DEMOLITION AND/OR OTHER WASTE MATERIALS CAUSED BY WORK OF THIS CONTRACTOR. LEGALLY DISPOSE ALL MATERIALS TO A LOCATION OFF SITE. COORDINATE AND SCHEDULE WORK AND SHUTDOWNS WITH THE OWNER AND OTHER TRADES PRIOR TO DEMOLITION. ALL EXISTING PIPING TO REMAIN SHALL BE RECONNECTED TO ACTIVE SERVICE PIPING. ALL PIPING TO BE REMOVED, SHALL BE REMOVED BACK TO ACTIVE PIPING AND CAPPED. VALVE AND CAP ALL WATER PIPING. REMOVE ALL INACTIVE PIPING UNLESS NOTED. ALL PIPING TO BE REMOVED AND LOCATED WITHIN A WALL TO REMAIN MAY BE ABANDONED IN PLACE UNLESS NOTED. REMOVE PIPING BACK TO BEHIND THE FINISHED WALL SURFACE AND CAP. PATCH HOLES IN EXISTING CONSTRUCTION LEFT BY THE REMOVAL OF PIPING OR EQUIPMENT WITH MATERIALS TO MATCH EXISTING CONSTRUCTION. MAINTAIN FIRE/SMOKE RATING. DEMOLITION SHALL INCLUDE, BUT NOT BE LIMITED TO: PIPING, VALVES, FIXTURES, EQUIPMENT, HANGERS, SUPPORTS, AND INSULATION EXCEPT ASBESTOS. REMOVE EXISTING CONSTRUCTION IN THE WAY OF NEW WORK. PROTECT BUILDING AND FURNISHINGS FROM DAMAGE. WHERE NEW WORK IS TO BE INSTALLED ABOVE AN EXISTING CEILING, PROVIDE FOR THE REMOVAL OF THE CEILING. UPON COMPLETION OF WORK, REPAIR ALL DAMAGED CEILING SURFACES, REPLACE ALL DAMAGED TILES. SLEEVE AND SEAL ALL WALL AND FLOOR PENETRATIONS. PROVIDE FIRESTOPPING FOR ALL PENETRATIONS. MAINTAIN SERVICE CLEARANCES OF ALL EQUIPMENT. ADVISE OTHER TRADES OF THE REQUIRED SERVICE CLEARANCES. PROVIDE FOR THE DRAINING AND REFILLING OF PIPING SYSTEMS, INCLUDING AIR REMOVAL, RESETTING OF FLUSH VALVES, FLUSHING SYSTEMS OF DIRT AND SCALE CAUSED BY SHUTDOWNS AND STARTUPS. REFER TO EQUIPMENT/ FIXTURE SCHEDULE FOR FINAL CONNECTION SIZES. PROVIDE CLEANOUTS AT THE BASE OF ALL STORM, SANITARY AND WASTE STACKS. PITCH 4" AND LARGER LAB WASTE PIPING AT 1/8" PER FOOT UNLESS OTHERWISE NOTED. FOR SANITARY AND WASTE PIPING 3" AND SMALLER PITCH AT 1/4" PER FOOT UNLESS OTHERWISE NOTED. A. B. C. D. E. F. G. H. I. J. K. L. M. N. O. P. Q. R. GENERAL NOTES: NOT TO SCALE4GAS PIPING SHUT-OFF DETAIL NOT TO SCALE 2 SINK WITH EYEWASH DETAIL 1 06/10/21 ADDENDUM No. 1 1 REFER TO DETAIL 2 ON P-000. REMARKS: EW-A EYE WASH 1/2" TEPID - - - 1 SK-C SINK 1/2" 1/2" 1/2" 1/2" 2" 1 1/2" - SK-B SINK-ADA 1/2" 1/2" 1/2" 2" 1 1/2" - SK-A SINK 1/2" 1/2" 1/2" 2" 1 1/2" - DESIGNATION DESCRIPTION COLD WATER HOT WATER DI WATER DECHLORINATED WATER LAB WASTE LAB VENT REMARKS FIXTURE AND EQUIPMENT CONNECTION SCHEDULE F H 14 15 16 SK-A SK-B LW 2"LW LW ●●● ●●● (E)DI(E)G ●●●(E)DI(E)G●●● ●●● (E)DI (E)G ●●(E)DC●(E)DI(E)2" BUBBLER AIR & (E)3/4" CO2(E)BUBBLER AIR (E)2" (E)DC (E)3/4" (E)3/4" CW, (E)3/4" HW, (E)3/4" DI & (E)3/4" DC (E)G(E)DI ●● ● (E)3/4" CW, (E)3/4" HW, (E)3/4" DI & (E)3/4" G (E)4" LW (BURIED) (E)SINK TO REMAIN (E)FD TO REMAIN (E)4" LW UP & DN (E)LW LW 1 1/2" ● 1/2" 1/2" CW, 1/2" HW & 1/2" DI IN CASEWORK TO SINK. 1/2" CW, 1/2" HW & 1/2" DI IN CASEWORK TO SINK. 2" LW DN. REFER TO DETAIL 4 ON P-000. 1/2" CW & G DN IN WALL. CUT & PATCH WALL AS REQUIRED.●●●DIEW-A SK-A SK-C 1/2" CW, 1/2" HW, 1/2" DI & 2" LW TO SINK. DROP PIPING IN CASEWORK CHASE. COORDINATE LOCATION WITH G.C. (E)4" LW UP & DN (E)EMER. SHOWER (E)1/2" CW, (E)1/2" HW, (E)1/2" DI & (E)1 1/2" LW DN TO SINK ROUTE LW TO AVOID SINK LEGS. COORDINATE WITH G.C. RECONNECT SINK WITH (E) SUPPLY PIPING, MODIFY AS REQUIRED FOR NEW CONNECTION. PROVIDE NEW LAB WASTE AND ROUTE AROUND SINK TABLE LEGS. 1/2" CW, 1/2" HW, 1/2" DI & 1/2" G DN. ROUTED TO SINK IN CASEWORK CHASE. G 1/2" RECONNECT 1/2" CW & 1/2" G TO FUME HOOD. 1/2" 1/2" 1/2" 1/2" WET LAB E142 MICROSCOPY/ MICROINJECTION E138 PREP E142A ANIMAL ROOM E136 GO-A ROUTE 1/2" G UNDER CASEWORK TO GO-A. 1 1/2" LW RACKED ON WALL UNDER CASEWORK. LV 1 1/2" (E)4" LV UP & DN EW-A GAS SHUT-OFF. SUPPLY RELAY CONTROL PANEL AND SWITCH. ELECTRICAL CONNECTION BY EC. REFER TO DETAILS FOR FURTHER REQUIREMENTS. PROVIDE SIGNAGE. GAS SOLENOID VALVE. REFER TO DETAILS FOR FURTHER REQUIREMENTS. 1 1 1 1 1 1 1 1 1/2" GAS DN IN WALL. ROUTE PIPING IN CASEWORK CHASE TO OUTLET. GO-A. INSTALL TO MEET ADA. (E)DC 1 1/2" V UP. CONNECT TO VENT STACK IN CHASE. 1 1/2" LV IN CASEWORK CHASE 3 3 3 2" 2" 2" LW TO SINK 2" LW TO SINK G 1/2" EW-A (E)CA3/4" PROVIDE 3/4" CA DN W/ REGULATOR. DESIGN BASIS WATER SAVER CT 2873-366V-758WSA. PROVIDE MANIFOLD WITH 6 CA OUTLETS. DESIGN BASIS WATER SAVER CT 5280F-225WSA. PROVIDE ALL REQUIRED FITTINGS. 1 F H 14 15 16 ●●● ●●● (E)DI(E)G ●●●(E)DI(E)G●●●(E)DI●●● ●●● (E)DI (E)G ●●(E)DC●(E)DI(E)2" BUBBLER AIR & (E)3/4" CO2(E)BUBBLER AIR (E)2" (E)DC (E)3/4" (E)3/4" CW, (E)3/4" HW, (E)3/4" DI & (E)3/4" DC (E)G(E)DI ●●● (E)3/4" CW, (E)3/4" HW, (E)3/4" DI & (E)3/4" G (E)4" LW (BURIED) (E)SINK TO REMAIN CUT & PATCH FLOOR AS REQUIRED TO CAP PIPING BELOW FLOOR. CUT & PATCH WALL AS REQUIRED TO CAP PIPING BELOW FLOOR. CUT & PATCH WALL AS REQUIRED TO REMOVE PIPING BEHIND WALL. 1 1 REMOVE (E)1/2" CW, (E)1/2" HW, (E)1/2" DI & (E)2" LW TO SINK (E)FD TO REMAIN 1 REMOVE (E)1/2" CW, (E)1/2" HW & (E)2" LW TO SINK (E)1/2" CW, (E)1/2" HW& (E)1 1/2" LW DN TO SINK (E)4" LW UP & DN (E)1 1/2" (E)1/2" (E)1/2" (E)LW ●● ●(E)LW(E)1 1/2"(E)LW (E)1 1/2" (E)LW (E)1/2" CW, (E)1/2" HW, (E)1/2" DI & (E)1 1/2" LW DN TO SINK REMOVE HOSE BIBS AND 1'-0" OF PIPE AND REINSTALL HOSE BIBS. 2 2 (E)DI 2 (E)4" LW UP & DN (E)EMER. SHOWER DISCONNECT (E)1 1/2" LW, (E)1/2" CW & (E)1/2" G TO FUME HOOD TO ALLOW FUME HOOD TO BE MOVED. 1 1 REMOVE PIPING BACK TO WALL AND CAP. CUT & PATCH WALL AS REQUIRED TO CAP PIPING. REMOVE PIPING UNDER CASEWORK REMOVE PIPING UNDER CASEWORK (E)4" LV UP & DN WET LAB E142 MICROSCOPY/ MICROINJECTION E138 PREP E142A ANIMAL ROOM E136 3 2 REMOVE EXPOSED PIPING AND CAP ABOVE CEILING (E)G ●●● (E)LW 2 (E)DC 4" LV UP REMOVE EXISTING VENT PIPING.(E)CA1 GENERAL NOTES: A. REMOVE, PROTECT AND REINSTALL CEILING AS REQUIRED. These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions6/11/2021 10:48:23 AMC:\Users\cmdoktor\Documents\200311_CorsonFirstFloor_P_Central_R20_cmdoktor.rvt20625.01 THK Partial First Floor Plans - Plumbing GDD CMD P-100R 100% Construction Documents Submission Cornell University Corson Hall Rm 136-142A Lab Renovation Ithaca, NY May 7, 20211/4" = 1'-0"2 1st Floor - Plumbing New Work 1/4" = 1'-0"1 1st Floor - Plumbing Demolition DEMOLITION NOTES 1 REMOVE SINK, FAUCET, AND ASSOCIATED PIPING. 2 DISCONNECT AND REMOVE PIPING BACK TO POINT OF DISCONNECT AND CAP. 3 REMOVE SINK AND FAUCET. MODIFY PIPING AS REQUIRED FOR NEW SINK. N DRAWING NOTES 1 CO2 OUTLETS ARE NOT USED. PROVIDE CAP ON NOZZLE. 3 COORDINATE WITH G.C. FOR SAWCUTTING OF BURIED PIPING. EACH LINE MUST BE RUN SEPARATE TO MAIN TO MAINTAIN VENTING. 1 06/10/21 ADDENDUM No. 1 PROJECT: Corson Hall Rm E136-E142A Lab Renovation Date: June 11, 2021 RFI Form RFI/Page/ Response Dwg./Spec./Rep.Section/Design Team Index Number Paragraph/Topic RFI Response 1 G-002 Can an allowance be utilized for the firestopping work shown on G-002? It is difficult to quantify what is needed for this. Additionally, if an allowance is issued, will this cover the fire rated soffit detail above? The soffit can be quantified, just want to know where the allowance would start and stop. Please refer to drawing detail 2/G-002, and the referenced photos, for the scope of work required. An allowance will not be utilized. 2 A-101 I do not find wall type U-10 used anywhere, can you direct me to what room this is used in?Refer to drawing detail 2/A-101. A location is indicated near column F15. 3 I do not find wall type A3 used, please advise which room this is used in. A3 matches construction of the north wall of room E138. A new opening and header is required in the existing wall. 4 The note about the temp partition describes a fiber lite liner panel adhered to plywood in the ceiling. Can we get a picture or detail showing what this is referring to? The intent is to construct a temporary partition without removing or damaging the existing ceiling. There are two types of ceiling tiles. The majority of the room consists of acoustical ceiling tiles, but some of the tiles are the described fiber-lite panel with plywood backing (generally occuring where utilities are located at the ceiling.) If the ceiling is damaged, the contractor is responsible for restoring the ceiling to its existing condition. Generally, the acoustical tiles should be replaced but it is likely that patching of the other will be necessary.