Corson Hall Third Floor Lab and Office Indexed Drawings (2)
Drawing List General G-000 Cover Sheet G-001 Code Compliance Plan & Notes Architectural A-000 General Notes and Legends A-101 Partial Third Floor Plans -E303-E305 A-102 Partial Third Floor Plans -E318-E334 A-103 Partial Third Floor Reflected Ceiling Plan -E318-E334 A-104 Partial Plans A-420 Interior Elevations -E303-E305 A-421 Interior Elevations -E318-E334 A-501 Interior Details, Lab Casework A-601 Interior Details & Door Schedule A-602 Finish Plans & Schedule A-603 Lab Equipment and Fume Hood Schedule A-604 Specifications Plumbing P-000 General Notes and Symbols List -Plumbing P-100 Partial Second Floor Plans -Plumbing P-101 Partial Third Floor Plans -Plumbing Demolition P-201 Partial Third Floor Plans -Plumbing Mechanical M-000 General Notes and Symbols List -HVAC M-100 Partial Third Floor Plans -HVAC M-101 Partial Fourth Floor and Roof Plans -HVAC M-200 Control Schematics & System Summaries M-201 Control Schematics & System Summaries M-202 Control Schematics & System Summaries M-203 Control Schematics & System Summaries M-204 Control Schematics & System Summaries M-205 Control Schematics & System Summaries M-300 Details -HVAC M-400 Schedules -HVAC Electrical E-000 Symbols List & General Notes -Electrical E-200 Partial Third Floor Plan -Power & Special Systems E-201 Partial Third Floor Plan -Lighting E-202 Partial Fourth Floor & Roof Plan -Electrical E-300 Electrical Details & Schedules Fire Protection FP-000 General Notes and Symbols List FP-100 Partial Third Floor Plans -Fire Protection Hazardous Materials AR-101 Asbestos Abatement Plan and Notes These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions SWBR Project #3/12/2021 11:34:44 AMBIM 360://20636.00 Cornell Corson Hall E303-E347/Cornell Corson Hall E303 E304 E305 E347 Lab and Office Renovation.rvt20636.00 CWJ Cover Sheet CWJ CRE G-000 100% Construction Documents Cornell University Corson Hall Third Floor Laboratory & Office Renovation Ithaca, NY March 5, 2021 March 5, 2021 Corson Hall Third Floor Laboratory & Office Renovation 100% Construction Documents 20636.00 215 Tower Rd Ithaca, NY 14853 Architect & Structural Engineer: SWBR 387 East Main Street Rochester, NY 14604 585 232 8300 rochester@swbr.com Mechanical, Electrical, Plumbing & Fire Protection Engineer: M/E Engineering 300 Trolley Blvd Rochester, NY 14606 585 288 5590 Regional Map Location Map Corson- Mudd Hall Corson- Mudd Hall Primary Access Road Entrance Loading Dock TOWER ROAD GARDEN AVECAMPUS ROAD TOWER ROAD GARDEN AVECAMPUS ROAD Environmental Engineer: Delta Engineers, Architects & Surveyors 860 Hooper Road Endwell, NY 13760 607 231 6600 E301 E303 E305 E309A E309B E309 E311 E304B E306 E304A E310 E340 E344A E344 E344B E344C E321 E323 E325 E331 E331A E335 E339E341E343E345E347 E351 E300SB E300SA E320 E300C E300E E339A W335B W335C W335D W335 W339 W311 W309 W307 W305 W303 W301 W320A W320 W316 W320B W316A W316B W314 W314A W308 W308A W308C W308D W302 W302A W364W360W358W354 W354A W350A W350W342 W343 W345 W347 W347A W351 W355 W359 W361 W363 W363A W300S W300C W308B W344 W350B W313 W317 W319W319A W321 W321A W327A W327BW327 W331W331A W335A W357 W319B A300C A300UE A300UF A305 A306 A300TB A300UG A367 A300TA A300S A300J OPEN TO BELOW OPEN TO BELOW E301 E303 E305 E309A E309B E309 E311 E304B E306 E304A E310 E340 E344A E344 E344B E344C E321 E323 E325 E331 E331A E335 E339E341E343E345E347 E351 E300SB E300SA E320 E300C E300E E339A DN UP DN UP DN UP DN DN DN UP DN UP FE XX PROJECT WORK AREA, SEE PLAN 2/G-001 FOR ROOM INFORMATION E EEATD = 126' -2" E315 E317A E317 E317B E317C E2FBE2FBE2FBE2FB EXISTING EMERGENCY SHOWER E2SE E2SE E2SEE2SEE2SEE2SEE2SEE2SEE2SE E2SE EXISTING CONTROL AREA BOUNDARYCONTROL AREA 1 CONTROL AREA 2 E2FBE2FBE2FBE2SEE2SEE2SEE2FBE2FBE2SE FE PROJECT WORK AREA, SEE PLAN 3/G-001 FOR ROOM INFORMATION EXISTING EMERGENCY SHOWER CPET = 45' -5" CPET = 32' -7" EXISTING CONTROL AREA BOUNDARY FE FECPET = 25' -10"EATD = 84' -8"FE E318 E334 CODE COMPLIANCE NOTES: 1. COMBINATION FIRE/SMOKE DAMPERS PROVIDED AT NEW DUCT PENETRATIONS THROUGH THE CORRIDOR WALL 2. WHERE NEW OPENINGS ARE PROVIDED, CORRIDOR WALLS ARE UPGRADED TO A 1- HOUR FIRE PARTITION CONSTRUCTION FOR PERIMETER OF THE IMMEDIATE WORK AREA (UL U1419) 3. NEW EMERGENCY POWER LOADS DO NOT EXCEED EXISTING EM POWER LOADS. (NO INCREASE IN EM PANEL LOADS.) E1FB 193 SF FACULTY OFFICE E303 189 SF LAB E305 E309A E309 311 SF LAB E304 E304A E306 75 SF DARK ROOM E304BE2FBE1FBE1FBE2SEE2SE E2SEE2SEE2SE E2FB E1FB E1FB E301 A300TB A300C E1FBE1FBE1FB E1FBE1FBE1FB CLASSIFICATIONS OF BUILDING, AS SPECIFIED IN THE 2020 EDITION OF THE BUILDING CODE OF NEW YORK STATE ARE AS FOLLOWS: BUILDING DATA AND CODE COMPLIANCE BUILDING DATA: CONSTRUCTION CLASSIFICATION: BUILDING OCCUPANCY CLASSIFICATION: FIRE PROTECTION SYSTEM: RENOVATION AREA: EXISTING FLOOR ASSEMBLY: 1A (PER RECORD DRAWINGS PROVIDED BY CORNELL) B -BUSINESS PARTIALLY SPRINKLERED 1,982 SF 2 HR FIRE-RATED E CODE COMPLIANCE PLAN LEGEND EXIT. MAINTAIN OPERATIONAL AT ALL TIMES DURING CONSTRUCTION EXIT SIGN INDICATES FIRE-RESISTANT WALL CONSTRUCTION OF VARIOUS TYPES AND HOURLY RATINGS. SEE FIRE-RESISTANT CONSTRUCTION LEGEND. SPECIFIC CODE INFORMATION NOTE POINT OF ORIGIN DECISION POINT CPET = X'-X" EATD = X'-X" COMMON PATH OF EGRESS TRAVEL CPET = X'-X" EGRESS ACCESS TRAVEL DISTANCE EATD = X'-X" CODE COMPLIANCE GENERAL NOTES CODE COMPLIANCE DRAWINGS ARE INTENDED TO ASSIST IN THE PERMIT PROCESS AND TO PROVIDE GENERAL INFORMATION TO THE CONTRACTORS WITH RESPECT TO LIFE-SAFETY PROVISIONS OF THE PROJECT. THESE DRAWINGS SHOULD NOT BE USED TO DETERMINE THE SCOPE OF OTHER WORK SPECIFICALLY INDICATED ELSEWHERE IN THE DOCUMENTS. THESE DRAWINGS SHALL BE USED FOR THE LOCATIONS OF FIRE- RESISTANT RATED WALL CONSTRUCTION. THE FOLLOWING BUILDING AND ACCESSIBILITY CODES AND STANDARDS ARE APPLICABLE TO THIS PROJECT: A. 2020 BUILDING CODE OF NEW YORK STATE B. 2020 FIRE CODE OF NEW YORK STATE C. 2020 PLUMBING CODE OF NEW YORK STATE D. 2020 MECHANICAL CODE OF NEW YORK STATE E. 2020 FUEL GAS CODE OF NEW YORK STATE F. 2020 ENERGY CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE G. NATIONAL ELECTRICAL CODE, NFPA 70, -2017 EDITION AS REFERENCED BY THE NYS CODES ABOVE. H. ICC A117.1, ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES -2009 EDITION AS REFERENCED BY THE NYS CODES ABOVE. I. U.S. DEPARTMENT OF JUSTICE, 2010 AMERICANS WITH DISABILITIES ACT (ADA) STANDARDS FOR ACCESSIBLE DESIGN. REFERENCE FCNYS CHAPTER 33 FOR FIRE SAFETY PROVISIONS DURING CONSTRUCTION, DEMOLITION. X X X" OCCUPANT CAPACITY CLEAR WIDTH OCCUPANCY LOAD FIRE EXTINGUISHER ACCESSIBLE ENTRANCE CONTROL AREA BOUNDARY MAX = 74'-0" (TABLE BC 1006.21) MAX = 200'-0" (TABLE BC 1007.2) FE FIRE RESISTANCE RATING SCHEDULE FOR BUILDING ELEMENTS CONSTRUCTION CLASSIFICATION TYPE 1A. DESCRIPTION TEST REFERENCE COMMENTSFIRE RESISTANCE RATING STRUCTURAL FRAME INCLUDING COLUMNS, GIRDERS AND TRUSSES 3, EXISTING -EXISTING ASSEMBLY, CONCRETE ENCASED STRUCTURAL STEEL INTERIOR AND EXTERIOR BEARING WALLS 3, N/A -N/A FLOOR CONSTRUCTION INCLUDING SUPPORTING BEAMS AND JOISTS 2, EXISTING -EXISTING ASSEMBLY, CAST-IN PLACE CONCRETE FLOOR SLAB ROOF CONSTRUCTION INCLUDING SUPPORTING BEAMS AND JOISTS 1 1/2, EXISTING -EXISTING ASSEMBLY FIRE-RESISTANT CONSTRUCTION LEGEND DESCRIPTION PLAN DESIGNATION FIRE WALL 2FW 3FW FIRE BARRIER (HORIZONTAL EXIT, INCIDENTAL USE/HAZARD, OCCUPANCY SEPARATION) 1FB 2FB SHAFT ENCLOSURE (FIRE BARRIER AT ELEVATOR, STAIR OR MECHANICAL SHAFT) 1SE 2SE FIRE PARTITION (ELEV LOBBY & CORRIDOR WALL) 1FP PRESUMED EXISTING FIRE-RATED ASSEMBLIES PREFIX E. SEE NOTE 1 WHEN THE PREFIX "E" IS INDICATED ON THE CODE COMPLIANCE FLOOR PLAN, IT DENOTES EXISTING WALL CONSTRUCTION WITH A PRESUMED FIRE-RESISTANCE RATING OF THE TYPE INDICATED AS INDICATED ON RECORD DRAWINGS PROVIDED BY THE OWNER. THE ACTUAL CONDITIONS IN THE FIELD HAVE NOT BEEN VERIFIED TO CONFIRM COMPLIANCE. NEW PENETRATIONS SHALL BE CONSTRUCTED IN ACCORDANCE WITH UL LISTED THROUGH-PENETRATION FIRE STOP SYSTEMS FOR THE RATING INDICATED. NEW OPENINGS TO BE PROTECTED WITH OPENING PROTECTIVES FOR RATING INDICATED. 2FW 3FW 1FB 2FB 1SE 2SE 1FP NOTES: 1. E E 2. PENETRATIONS THROUGH FIRE-RESISTANT CONSTRUCTION SHALL BE BUILT IN ACCORDANCE WITH U.L. LISTED THROUGH-PENETRATION FIRESTOP SYSTEMS. SEE CODE COMPLIANCE PLAN FOR FIRE-RATED PARTITIONS LOCATIONS.1FPE325 186 SF COMPUTATIONAL LAB E323 184 SF OFFICE E321 1FP1FP1FP 1FP1FP1FP1FP1FP E1FBE1FBE1FBE1FBE1FB E1FB 1FPCORRIDOR E300C 491 SF OPEN LAB E334 68 SF ACID WASH E334A 164 SF SOIL ROOM E318 55 SF VEST E334B E1FB E1FB NEW DOOR -20-MIN RATING REQUIRED PER TABLE BC716.1(2), 45-MIN PROVIDED. These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions3/12/2021 11:34:47 AMBIM 360://20636.00 Cornell Corson Hall E303-E347/Cornell Corson Hall E303 E304 E305 E347 Lab and Office Renovation.rvt20636.00 CWJ Code Compliance Plan & Notes CWJ CRE G-001 100% Construction Documents Cornell University Corson Hall Third Floor Laboratory & Office Renovation Ithaca, NY March 5, 2021 1/16" = 1'-0"1 Third Floor Code Compliance Plan - East Wing 1/8" = 1'-0"2 Third Floor Code Compliance Plan - E303-E305 N 1/8" = 1'-0"3 Third Floor Code Compliance Plan - E318-E334 GYPSUM BOARD / METAL STUD SERIES PARTITIONS7/8" METAL STUDS AT 16" O.C.(1) LAYER 5/8" GYPSUM BOARD AT ROOM SIDE ONLY.LEGENDINDICATES PARTITION TYPEINDICATES PARTITION HEIGHT ABOVEFINISHED FLOOR:"X" AFCPARTITION TO X" ABOVEFINISHED CEILINGUFCPARTITION TO UNDERSIDE OF FINISHED CEILINGX'-X"WHERE HEIGHT IS NOTED,CONSTRUCT WALL TO THATHEIGHT INCLUDING TOP OFWALL CAP4 7/8"3 5/8" METAL STUDS AT 16" O.C.(1) LAYER 5/8 " GYPSUM BOARD EACH SIDE.1 HOUR FIRE RESISTANT RATED WHEN INDICATED(WITH OR WITHOUT INSULATION) PER UL U419A3UNBALANCED SERIES PARTITIONS1 1/2"U3XX**A3INDICATES PARTITION TYPEINDICATES ADDITIONAL SOUND ATTENUATIONBLANKETS FOR ACOUSTICAL PURPOSES(REFER TO GENERAL PARTITION NOTES)AALL STUD PARTITIONS NOT INDICATED WITH A PARTITION TYPE SHALL BE TYPE A3A.PARTITIONS WITH SOUND ATTENUATION BLANKETS:GYPSUM BOARD TO BE "TYPE X" UNLESS OTHERWISE NOTEDALL PARTITIONS ARE TO BE TO THE UNDERSIDE OF DECK UNLESS OTHERWISE NOTEDDIMENSIONS SHOWN FOR EACH PARTITION DESCRIPTION INDICATE FACE-TO-FACETHICKNESS OF MATERIALS LISTED FOR THAT PARTITIONPROVIDE LISTED U.L. FIRE-RESISTANT JOINT ASSEMBLIES @ TOP OF ALL WALLS INDICATED TO BE FIRE-RESISTANT RATEDTHE TOP OF ALL PARTITIONS FRAMED AGAINST THE UNDERSIDE OF STRUCTURES SHALL HAVE PROVISIONS FOR DEFLECTION & RESTRAINT. SEE DETAIL 1/A-000.FOR STUD CONSTRUCTION NOT EXTENDING TO THE STRUCTURE, PROVIDE DIAGONAL BRACING FROM TOP OF WALL TO STRUCTURE ABOVE. INSTALL AT 12'-0" MAX SPACING AND @ EACH DOOR JAMBREFER TO CODE COMPLIANCE PLANS FOR PARTITION FIRE RESISTANCE RATINGS.GYPSUM BOARD JOINT TREATMENT IN CONCEALED SPACES SHALL BE FIRE TAPED. UNLESS OTHERWISE INDICATED IN A SPECIFIC UL DESIGN, JOINTS SHALL BE FIRE TAPED, AND JOINTS AND FASTENER HEADS COVERED WITH (1) COAT OF JOINT COMPOUND. BASE LAYERS IN MULTI-LAYER SYSTEMS ARE NOT REQUIRED TO HAVE JOINTS OR FASTENER HEADS TAPED OR COVERED WITH JOINT COMPOUND. FOR PARTITIONS SCHEDULED WITH BOARD ON (1) SIDE ONLY, PROVIDE 20 GA. MINIMUM PRE-NOTCHED BRIDGING/SPACING BARS (SIMILAR TO SPAZZER 9200 BY CLARK DIETRICH) AT 4'-0" O.C. HORIZONTALLY. AT CONTRACTORS' OPTION, 1-1/2" x 12GA. C.R. CHANNEL BRIDGING WITH 16 GA. CLIP ATTACHMENT TO EACH STUD CAN BE UTILIZED.GENERAL PARTITION NOTES:A.B.C.D.E.F.G.H.I.J.K.GENERAL NOTES:ALL GENERAL NOTES PERTAIN TO ALL ARCHITECTURAL (A-SERIES) DRAWINGS IN THIS SETWHERE DIFFERENT FLOORING MATERIALS MEET, AND A SPECIFIC TRANSITION DETAIL IS NOT INDICATED, PREPARE SUBSTRATE WITH A TRANSITION HEIGHT BUILD UP USING TROWELABLE LEVELING AND PATCHING COMPOUND TO PRODUCE A FLUSH SMOOTH CONDITION. TROWEL MATERIAL FOR A MINIMUM DISTANCE OF 2 FEET FROM A FEATHER EDGE CONDITION UP TO A MAXIMUM SINGLE LAYER APPLICATION THICKNESS OF 1/2". FOR APPLICATIONS THICKER THAN 1/2", PLACE MATERIAL IN SUCCESSIVE LAYERS, SCORING PREVIOUS LAYER, UP TO A MAXIMUM THICKNESS OF 1".PROVIDE CONCEALED STEEL STUD BLOCKING, FRT WOOD BLOCKING OR 4" x 18 GA CONTINUOUS STEEL STRAPPING ATTACHED TO FACE OF STUDS BEHIND ALL WALL MOUNTED ITEMS SUCH AS: WALL CABINETS, SHELVING, COAT RODS, ETC. SEE INTERIOR ELEVATIONS & FURNITURE PLANS FOR ADDITIONAL INFORMATION AND SCOPE.FLOOR FINISH TRANSITIONS/CHANGES SHALL OCCUR BELOW THE DOORDIMENSIONS LOCATING INTERIOR PARTITIONS ARE TO THE FACE OF WALL (EXCLUDING FINISHMATERIALS SUCH AS -BUT NOT LIMITED TO: CERAMIC TILE, AND WOOD PANELING) UNLESS NOTED OTHERWISE. SEE PARTITION SCHEDULE FOR WALL THICKNESSALL EXISTING DIMENSIONS ARE APPROXIMATE AND FOR CONTRACTORS VERIFICATIONS. IFDISCREPANCIES ARISE, NOTIFY THE ARCHITECT (AND/OR CONSTRUCTION MANAGER) PRIOR TO PROCEEDING WITH THE WORK THAT MAY BE EFFECTED BY THE DIMENSION CHANGEEVERY ATTEMPT HAS BEEN MADE TO INDICATE PERTINENT EXISTING UTILITIES AND CONDITIONS AS ACCURATELY AS POSSIBLE FROM EXISTING SURVEYS, DRAWINGS AND OTHER DATA. PRIOR TO THE BID OPENING, CONTRACTORS SHALL WALK THE JOB SITE AND SATISFY THEMSELVES TO EXISTING CONDITIONS. THE ARCHITECT SHALL BE CONSULTED WHEN ANY QUESTION ARISES RELATIVE TO MATERIALS NOT SPECIFICALLY SHOWN OR SPECIFIEDALL EXISTING WORK (CEILINGS, FLOORS, WALLS, PARTITIONS, FINISHES, ETC.) DISTURBED BY NEW CONSTRUCTION, INCLUDING MECHANICAL, PLUMBING, AND ELECTRICAL, SHALL BE PATCHED AND REPAIRED TO RESTORE SURFACES TO THE ORIGINAL CONDITION AFTER INSTALLATION OF OTHER WORKPENETRATIONS THROUGH FIRE-RESISTANT CONSTRUCTION SHALL BE BUILT IN ACCORDANCE WITH U.L. LISTED THROUGH-PENETRATION FIRESTOP SYSTEMS. SEE CODE COMPLIANCE PLAN FOR PARTITION LOCATIONS. PENETRATIONS THROUGH NON FIRE-RESISTANT RATED HORIZONTAL ASSEMBLIES, NOT PROTECTED BY A SHAFT ENCLOSURE, SHALL HAVE ITS ANNULAR SPACE FILLED WITH NON-COMBUSTIBLE MATERIAL TO PREVENT THE PASSAGE OF FLAME, SMOKE FUMES, AND HOT GASES. NON-COMBUSTIBLE PENETRATING ITEMS SHALL NOT PENETRATE MORE THAN 3 FLOOR ASSEMBLIES. COMBUSTIBLE PENETRATING ITEMS SHALL NOT PENETRATE MORE THAN 1 FLOOR ASSEMBLY.1.2.3.4.5.6.7.8.9.PROVIDE SOUND ATTENUATION BLANKETS IN ALL CAVITY SPACES IN WALL FULL HEIGHTTHICKNESS OF BLANKETS IN STUD WALLS SHALL BE EQUAL TO THICKNESS OF CAVITY TO NEAREST 1/2", UNLESS INDICATED OTHERWISEPARTITIONS TO BE SEALED @ THE PERIMETER, BEHIND CONTROL JOINTS, AROUND OPENINGS AND AT ALL PENETRATIONS WITH EACH LAYER OF BOARD TO RECEIVE A BEAD OF NON-HARDENING SEALANTSEE WALL TYPE DESCRIPTIONS FOR CONDITIONS REQUIRING MINERAL FIBER SAFING INSULATION BATTS1.2.3.4.REFER TO CODE COMPLIANCE PLAN(S) FOR PARTITIONS REQUIRED TO BE FIRE-RESISTANT-RATED CONSTRUCTION.JOB SPECIFIC PARTITIONSJ12 1/2" METAL STUDS AT 16" O.C.(1) LAYER 1/2" GYPSUM BOARD EACH SIDE.3 1/2"J23 5/8" METAL STUDS AT 16" O.C.(2) LAYER 1/2" GYPSUM BOARD CORRIDOR SIDE.(1) LAYER 1/2" GYPSUM BOARD ROOM SIDE.5 1/8"2 1/2" METAL STUDS AT 16" O.C.(1) LAYER 5/8" GYPSUM BOARD AT ROOM SIDE ONLY.3 3/8"U63 5/8" METAL STUDS AT 16" O.C.(1) LAYER 5/8" GYPSUM BOARD AT ROOM SIDE ONLY.4 1/4"U81-HOUR RATED SHAFT WALL.2 1/2" METAL C-H STUDS AT 24" O.C.(1) LAYER 5/8" GYPSUM BOARD AT ROOM SIDE ONLY.(1) LAYER 1" TYPE "X" GYPSUM LINER PANELS AT SHAFT SIDE.FULL HEIGHT PARTITION TO UNDERSIDE OF DECK.1-HOUR RATED PER ASSEMBLY U.L. #U469SHAFT WALL SERIES PARTITIONS3 1/8"S17 1/4"6" METAL STUDS AT 16" O.C.(1) LAYER 5/8 " GYPSUM BOARD EACH SIDE.1 HOUR FIRE RESISTANT RATED WHEN INDICATED(WITH OR WITHOUT INSULATION) PER UL U419A6EXISTING CONCRETE DECKSCREW FASTENER TO STUDS ONLY2" x 20 GA. MIN DEEP LEG DEFLECTION TRACKCONT. LATERAL BRACE WITHIN 12" OF TOP TRACK 1 1/2 C.R. CHANNEL W/ 16 GA. CLIP ANGLE OR CONT. STRAPPING ON EA. SIDESTEEL STUDCUT STUDS 1" SHORT OF DECK OR BEAMGYPSUM BOARD -EXTEND TO TOP OF STUD ELEVATIONAT FIRE -RATED PARTITIONS:CONSTRUCT DETAIL IN ACCORDANCE WITH U.L. LISTED FIRE-RESISTANT JOINT SYSTEMS (HW-D). PROVIDE DEFLECTION TRACK ASSEMBLIES, FORMING/ FILL MATERIALS AS REQUIRED BY APPROVED JOINT SYSTEMAT NON-RATED PARTITIONS & SMOKE PARTITIONS: FOR PARTITIONS CONTAINING SOUND BATT INSULATIONPACKING MATERIALFILL MATERIAL/SEALANTBOND BREAKER TAPE3"6"3"T/O WALL CABINETB/O WALL CABINETT/O BASE CABINETFINISHED FLOORSCHEDULED PARTITION3"2x6 WOOD BLOCKINGT/O WALL CABINETB/O WALL CABINETT/O BASE CABINETFINISHED FLOORSCHEDULED PARTITION6"x16ga CONTINUOUS SHEET METAL: (2) SHEET METAL SCREWS PER STUD3"3"3"6"NOTE: REMOVE AND PATCH GYPSUM BOARD AS REQUIRED TO INSTALL BLOCKING INDICATEDThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions3/15/2021 3:42:23 PMBIM 360://20636.00 Cornell Corson Hall E303-E347/Cornell Corson Hall E303 E304 E305 E347 Lab and Office Renovation.rvt20636.00CWJGeneral Notes andLegendsCWJCREA-000100% ConstructionDocumentsCornell UniversityCorson Hall Third FloorLaboratory & Office RenovationIthaca, NYMarch 5, 2021AB Anchor boltA/C Air condition(ing) (ed)ACC AccessibleACCU Air cooled condensing unitACI American Concrete InstituteACT Acoustical ceiling tileACM Asbestos containing materialACOUS PNL Acoustical panelACS PNL Access panelADDL AdditionalADJ Adjustable, adjacentADH AdhesiveAFF Above finished floorAGGR AggregateAHU Air handling unitAISC American Institute of Steel ConstructionAISI American Iron and Steel InstituteALT AlternateALUM AluminumANOD AnodizedAPPROX ApproximateARCH Architect(ural)ARD Auxillary roof drainASD Allowable stress designASTM American Society for Testing and MaterialsAWP Acoustical wall panelAWS American Welding SocietyBAT BattenB/B Back to backB BD Base boardBCNYS Building Code of New York StateBITUM BituminousBD BoardBLDG BuildingBLKG BlockingBM Beam, BenchmarkBOT BottomBR BedroomBRG BearingBRZ BronzeBSMT BasementBTWN BetweenBUR Built up roofingBW Both waysCCTV Closed circuit televisionCAB CabinetCB Catch basin, Corner beadCH BD ChalkboardCEM CementCF Contractor furnishedCFMF Cold-formed metal framingCF/CI Contractor furnished/ Contractor installedCF/OI Contractor furnished/ Owner installedCG Corner guardCH Coat hookCI Cast ironCIP Cast in place, Cast iron pipeCJ Control jointCL CenterlineCLG CeilingCLO ClosetCLR Clear, ColorCMT Ceramic mosaic tileCMU Concrete masonry unitCNTR CounterCO Cleanout, Cased opening, CompanyCOL ColumnCONC ConcreteCONF ConferenceCONN Connect(ion)CONSTR ConstructionCONT Continue(ous)CONTR Contract(or)COORD CoordinateCPT CarpetCSJ Construction jointCSK Counter sunkCT Ceramic tile, Count, Current transformerCTR CenterCW Cold water piping, Casement windowCU CubicCUH Cabinet unit heaterCU YD Cubic yardD Deep, DepthD Penny (nail)db Bar diameterDBL DoubleDEFS Direct-applied exterior finish systemDEG DegreeDEMO DemolitionDEPT DepartmentDET DetailDF Drinking fountainDIA OR ø DiameterDIAG Diagonal, DiagramDIM DimensionDIFF DiffuserDIR DirectionDISP DispenserDIV DivisionDMPF Damp proofingDL Dead loadDN DownDO DittoDR Door, DriveDS DownspoutDW DishwasherDWVDrainage waste & ventDWGDrawingDWLDowelEEastEAEachEBCNYSExisting Building Code of New York StateECElectrical contractorEFEach faceEIFSExterior insulation and finish systemEJExpansion jointELASElastomericELElevationELECElectric(al)ELEVElevatorEMEntry mat, Expanded metalEMEREmergencyENCLEnclosureENGREngineerEOSEdge of slabEPElectric panelEQEqualEQUIPEquipmentESEmergency showerETCEt ceteraETRExisting to remainEWEach wayEWCElectric water coolerEXISTExistingEXCExcavation, ExcavateEXPExpand, ExpansionEXTExterior, External, ExtinguisherF/FFace to faceFAAPFire alarm annunciator panelFACPFire alarm control panelFDFloor drainFDTNFoundationFEFire extinguisherFECFire extinguisher cabinetFHCFire hose cabinetFINFinish(ed)FIXTFixtureFLASHFlashingFLEXFlexibleFLOURFluorescentFLGFlooring, flangeFOFinished openingFPFire protection, FireproofFRTWFire retardant treated woodFTFoot, FeetFTGFootingFTRFinned tube radiationFURNFurnace, Furniture, FurnishFUTFutureFWCFabric wall coveringGAGageGALGallonGALVGalvanizedGBGrab barGCGeneral contract(or)GFRCGlass fiber reinforced concreteGFRGGlass fiber reinforced gypsumGLGlass, Ground levelGL BLKGlass blockGLU LAMGlued laminated beamGRGrade, GrossGWTGlazed wall tileGYPGypsumGYP BDGypsum boardGYP PLASGypsum plasterHBHose bibbHCHollow core, Hose cabinetHCPHandicappedHDWHardwareHDWDHardwoodHMHollow metalHOHold openHORIZHorizontalHPHigh point, HorsepowerHRHourHSSHollow structural sectionHTHeightHTGHeatingHTRHeaterHVACHeating, ventilating and air conditioningHWHot waterHYDHydrantIDInside diameterINInchesINCLIncludedINCANDIncandescentINFOInformationINSULInsulationINTERMIntermediateINTInteriorJANJanitorJSTJoistJTJointKIP1000 PoundsKITKitchenKOKnockoutKPLKick plateLLiter, AngleLAMLaminate(d)LAULaundryLAVLavatoryLBPoundLBLLabelLDLoadLFLinear feet (foot)LHLeft hand, Latent heatLINLinearLKRLockerLLLive loadLLHLong leg horizontalLLVLong leg verticalLOCLocationLRFDLoad & resistance factor designLTLightLTGLightingLWCLight-weight concreteMACHMachineMAINTMaintenanceMASMasonryMATLMaterialMAXMaximumMCMechanical contractorMCBMetal corner beadMDOMedium density overlayMDFMedium density fiberboardMECHMechanicalMEPMechanical, electrical, plumbing and fire protectionMEZZMezzanineMFRManufacturerMHManholeMMMillimeterMIFRCMastic/intumescent fire-resistive coatingMINMinimumMISCMiscellaneousMLWKMillworkMOMasonry openingMRK BDMarker boardMTDMountedMTLMetalMULLMullionNNorthNATNaturalNCOMBLNoncombustibleNICNot in contractNO OR #NumberNOMNominalNORMNormalNRCNoise reduction coefficientNTSNot to scaleNWCNormal weight concreteO/OOut to outOAOverall, Outside airOCOn centerODOutside diameterOF/CIOwner furnished, Contactor installedOF/OIOwner furnished, Owner installedOFDOverflow drainOFFOfficeOHOpposite handOH DROverhead (coiling) doorOPNGOpeningOPPOppositeOPTOptional, OptimumOZOuncePAPublic addressPBDParticleboardPCPlumbing contractor, Portland cementPCCPrecast concretePCTPorcelain ceramic tilePEDPedestalPENDPendantPERPeriodPERFPerforatedPGBDPeg boardPLPlate, Property linePLFPonds per linear footPLAMPlastic laminatePLASPlasterPLBPlumbingPLYWDPlywoodPNLPanelPOLPolishedPORCPorcelainPOSPositive, PositionPPTPressure-preservative treatedPRPairPREFABPrefabricatePREFINPrefinishPREPPreparationPROJProjectPROJ SCRN Projection screenPSFPounds per square footPSIPounds per square inchPTPaint, Post tensionPTNPartitionPVCPolyvinyl chloride (plastic)PVGPavingQTQuarry tileQTRQuarterQTYQuantityRRiser, Radius, Thermal resistanceRBRubber base, Resilient baseRCPReinforced concrete pipe, Reflected ceiling planRDRoof drain, RoadRECRecessedREFRefrigeratorREFLReflectREGRegister, RegulationREINFReinforcedREQDRequiredRESILResilientREVRevisionRFResilient flooringRFGRoofingRHRight hand, Roof hatchRMRoomRORough openingROWRight of wayRTURoof top unitRVRoof ventRWBRubber wall baseSSouthSABSound attenuation battsSANSanitarySCSolid core, Shading coefficientSCHEDScheduleSEALSealer on floor (finish)SECTSectionSFSquare foot, Safety factorSFRMSprayed fire-resistiveMaterialSGTStructural glazed tileSHTSheetSHRShowerSIMSimilarSOGSlab on gradeSPStandpipe, Sump pitSPASpacesSPKRSpeakerSPECSpecificationSQSquareSRDSecondary roof drainSSService sinkSSMSolid surface materialSSPStainless steel pipeSSTStainless steelSTStainSTAStationSTCSound transmission classSTDStandardSTIFFStiffenerSTLSteelSTORStorageSTRStraight, StringersSTRUCTStructuralSUSPSuspendedSVSheet vinylSYSquare yardTTreadT/Top ofT&BTop and bottomT>ongue and grooveTELTelephoneTHRESThresholdTEMPTemporaryTERTerrazzoTHKThick(ness)TK BDTack boardTMPDTemperedTOCTop of concreteTOMTop of masonryTOPOTopography, TopographicTOSTop of steelTOWTop of wallTPDToilet paper dispenserTSTATThermostatTVTelevisionTYPTypicalUHeat transfer coefficientUCUndercutUCLUnder cabinet lightingUGNDUndergroundUHUnit heaterULUnderwriter's laboratoriesUNEXUnexcavatedUNFINUnfinishedUONUnless otherwise notedUTILUtilityUVUnit ventilatorVARNVarnish(ed)VBVinyl baseVCTVinyl composition tileVENTVentilationVERTVerticalVESTVestibuleVIFVerify in fieldVINVinylVOLVolumeVRVapor retarderVTVinyl tileV SHTVinyl sheetVWCVinyl wall coveringWWestW/WithWCWater closet, Wall coveringW/OWithoutWDWoodWDWWindowWFWide flangeWD GDWood guardWHWater heaterWIWrought ironWMWire meshWPWaterproofing, Working pointWRWater repellent, weather resistantW RECPTWaste receptacleWSCTWainscotWTWeight, Watertight, Water tableWWFWelded wire fabricXByYDYardC12AC12A-XXX1432XSCALE: X"=1'-0"Title112BA18'-0" AFF1Batt insulationRigid insulationWood blocking (intermittent) StoneGravel or crushed stoneWood framing (continuous)Finish woodSteel - large scaleSteel - small scalePlywoodConcreteConcrete masonry unitBrick(Other metals as noted)View titleBuilding / wall section cutDetail - blow upExterior elevationInterior elevations1011Partition typeRoom numberDoor numbersWindow typeRevisionORORUndisturbed earth001100A001Structural gridViewing directionDetail no.Drawing no.Detail no.Drawing no.Drawing no.Elevation no.Plan key noteDemolition key noteCeiling type and heightDrawing symbols(Other metals as noted)A-XXXXA-XXXXGypsum, sand, mortarA-XXXXDrawing no.Elevation no.Detail no.Detail section cutDetail no.DRAWING NO.A-XXXXViewing directionAccessibilityAccessible unitV/HAUVisual / hearing accommodation unitMaterial symbolsArchitectural / Structural abbreviations3" = 1'-0"1TYP. DEFLECTION HEAD DETAIL1/2" = 1'-0"2Blocking Location Detail 1019E_E404A200JACDF1213303305304304B6141234101151817131415219+/- 16' - 0"9711475811111314161717581711720PROVIDE AND MAINTAIN TEMPORARY PROTECTION DURING DEMOLITION & CONSTRUCTION AT ALL FIN TUBE COVERS TO REMAIN2132ACDF1213VIF4' - 10"VIF3' - 10"VIF3' - 11"VIF4' - 10"VIF8' - 8"VIF8' - 8"FACULTY OFFICEE303LABE305LABE304DARK ROOME304BA-42011A-4201AJ1213A-42087JE304A3A-42064510U8HGBACDEF5' - 0"+/- 4' - 6 1/4"2' - 6"2' - 1"1' - 7"2' - 6"2' - 6"2' - 6"2A-6011222432201120422222252120263202323232121213141415( 9' - 11" )( 19' - 10" )( 9' - 9" )( 20' - 10" )KLME305E30314A-501H-1E304E304B319151411' - 1"2' - 1"2' - 1"2' - 1"6' - 9"1623320A6A66' - 9"NELECTRICAL PANEL, SEE ELECTRICAL DRAWINGSU8U8ALIGN1"2' - 1"1' - 11"( 11' - 8 3/4" )( 19' - 1 1/4" )( 9' - 1 1/4" )4A-101FACULTY OFFICEE303LABE305LABE304DARK ROOME304B18' -6"18' -6"18' -6"AJ118' -6"28' -4"28' -4"6A-1015A-1015A-101EQEQEQEQTYP. @ CURTAINWALLMTL STUD & GYP BD INFILL @ TOP OF EXIST PARTITIONSSSS1' - 6"2' - 0"EQEQEXISTING CONT. WD BLOCKING, PT EXPOSED EDGES BLACKANGLE MOLDINGSCHEDULED CEILING, REFER TO RCP FOR HEIGHT+/- 2" VIFROLLER WINDOW SHADE & FASCIA, VERIFY MOUNTING IN FIELDEVERY ATTEMPT HAS BEEN MADE TO DOCUMENT PERTINENT EXISTING CONDITIONS FROM EXISTING SURVEYS, DRAWINGS AND LIMITED FIELD INSPECTION. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS SHALL WALK THE SITE AND SATISFY THEMSELVES TO EXISTING VISUAL CONDITIONS. THE ARCHITECT SHALL BE CONSULTED WHEN ANY QUESTION ARISES RELATIVE TO MATERIALS AND CONDITIONS NOT SPECIFICALLY SHOWN OR SPECIFIED.ALL EXISTING WORK (CEILING, FLOORS, WALLS, FINISHES, ETC.) DISTURBED BY NEW CONSTRUCTION SHALL BE PATCHED AND REFINISHED. PATCHING AND FINISH WORK IS THE REPAIR WORK REQUIRED TO RESTORE SURFACES TO THE ORIGINAL CONDITION AND/ OR MATCHING THE ADJACENT SURFACES. MISCELLANEOUS FINISH REQUIREMENTS TO WALL, FLOOR AND CEILING IN AREAS AFFECTED BY DEMOLITION HAVE NOT BEEN TOTALLY INCORPORATED INTO THE ROOM FINISH SCHEDULE. REFER TO THE DEMOLITION , FLOOR AND REFLECTED CEILING PLANS FOR ADDITIONAL CUTTING , PATCHING AND REFINISHING WORK SCOPE.CONTRACTOR(S) SHALL COORDINATE ALL WORK WITH HAZARDOUS MATERIALS ABATEMENT WORK. SOME ITEMS ON DEMOLITION PLAN WILL REQUIRE REMOVAL PRIOR TO START OF ABATEMENT WORK.THE EXISTING FIRE-RESISTANT CONSTRUCTION MUST BE MAINTAINED OR MADE TO COMPLY WITH THE REQUIREMENTS AS ESTABLISHED BY THIS CONTRACT. SEE THE CODE COMPLIANCE PLANS FOR THE FIRE RESISTANT RATINGS OF EXISTING AND NEW CONSTRUCTION.CARE SHALL BE TAKEN TO LIMIT IMPACT OF CONSTRUCTION ON THE SURROUNDING OCCUPANTS AND OPERATIONS DURING THE PROJECT. SAFE LEGAL PASSAGES SHALL BE PROVIDED FOR ALL BUILDING OCCUPANTS DURING ALL THE PHASES OF THIS PROJECT.WHEN EXISTING CONSTRUCTION WHICH IS TO REMAIN IS DAMAGED DURING THE COURSE OF CONSTRUCTION AS A RESULT OF CONTRACTOR'S WORK, IT SHALL BE REPAIRED AND/OR REPLACED WITH SIMILAR OR LIKE MATERIALS, SUBJECT TO ARCHITECT'S APPROVAL AND WITHOUT COMPENSATION.'REMOVE' IS DEFINED AS DETACH FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSE OF OFF-SITE UNLESS INDICATED TO BE SALVAGED OR REINSTALLED1.2.3.4.5.6.7.GENERAL DEMOLITION NOTES:GENERAL NOTES:ALL FLOORS, WALLS, CEILINGS, AND OTHER SURFACES THAT ARE TO REMAIN ARE TO BE PATCHED, REPAIRED, AND REFINISHED PRIOR TO FINISH INSTALLATION. ALL SURFACES ARE TO BE RESTORED TO THEIR ORIGINAL CONDITION AND/OR MATCH THE ADJACENT SURFACES.FIRESTOP ALL FLOOR PENETRATIONS (USED/UNUSED/ABANDONED) WITH 2 HR UL LISTED PENETRATION FIRESTOPPING.OF/CI: OWNER FURNISHED, CONTRACTOR INSTALLEDOF/OI: OWNER FURNISHED, OWNER INSTALLEDDIMENSIONS WITHIN PARENTHESES, (X' -X"), HAVE BEEN PROVIDED FOR REFERENCE ONLYSEE A-603 FOR FUME HOOD (" ") AND OF/OI LAB EQUIPMENT (" ")1.2.3.4.5.XXRCP LEGENDGYP BD CLG OR SOFFITCEILING GRIDEXIT LIGHT2'X4' LED FIXTURE2'X2' LED FIXTURE1'X4' LED FIXTURESPRINKLER HEADSUPPLY DIFFUSER, REFER TO MECHANICAL DRAWINGS RETURN AIR GRILLE, REFER TO MECHANICAL DRAWINGS 12X2 ACT-1CEILING TYPESGYP BD CLG OR SOFFIT, PT2EXISTING CEILING TO REMAINE2"DEFLECTION HEADBACKER ROD & SEALANTSOUND ATTENUATION BLANKETSEXISTING 2 1/2" MTL STUD PARTITION W/ 1/2" GYP BD EA. SIDE1/2" GYP BD ON 2 1/2" MTL STUDS @ 16" OCANGLE MOLDINGLINE OF STRUCTURE3 5/8" x 20GA MTL STUD DIAGONAL BRACING @ 4'-0" OC MAXLIGHT GAUGE CLIP ANGLEEXIST CEILING TILESCHEDULED CEILINGNOTE: EXTEND SOUND ATTENUATION BLANKETS AS FAR INTO EXISTING OFFICE 311 AS POSSIBLEFLAT STRAPPING @ 12" OCVERIFY THICKNESS IN FIELDDEFLECTION HEADBACKER ROD & SEALANT, EA SIDESOUND ATTENUATION BLANKETS1/2" GYP BD ON 2 1/2" MTL STUDS @ 16" OCANGLE MOLDING, EA SIDELINE OF STRUCTURE3 5/8" x 20GA MTL STUD DIAGONAL BRACING @ 4'-0" OC MAXLIGHT GAUGE CLIP ANGLEEXISTING 2 1/2" MTL STUD PARTITION W/ 1/2" GYP BD EA. SIDEALIGN FACE OF GYP BD, EA SIDE. SHIM AS REQUIRED.MODIFIED EXIST CEILING TILESCHEDULED CEILINGThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions3/15/2021 3:42:27 PMBIM 360://20636.00 Cornell Corson Hall E303-E347/Cornell Corson Hall E303 E304 E305 E347 Lab and Office Renovation.rvt20636.00CWJPartial Third FloorPlans - E303-E305CWJCREA-101100% ConstructionDocumentsCornell UniversityCorson Hall Third FloorLaboratory & Office RenovationIthaca, NYMarch 5, 20211/4" = 1'-0"1Partial Third Floor Demolition Plan - E303-E3051/4" = 1'-0"2Partial Third Floor Plan - E303-E3051/4" = 1'-0"3Partial Third Floor Reflected Ceiling Plan - E303-E305DEMOLITION KEY NOTESNO.DESCRIPTION1 REMOVE SHELVING AND WALL STANDARDS IN THEIR ENTIRETY. PATCH ANDREPAIR GYP BD PARTITION TO RECEIVE SCHEDULED FINISH.2 REMOVE WD DOOR, FRAME & ASSOCIATED COMPONENTS. TURN LOCKCYLINDERS OVER TO OWNER. PREPARE OPENING TO RECEIVE SCHEDULEDDOOR. MARBLE THRESHOLD TO REMAIN.3 REMOVE DOOR, FRAME, & ASSOCIATED COMPONENTS INCLUDING SHELVESINSTALLED ON DOOR PANEL. TURN LOCK CYLINDERS OVER TO OWNER.4 REMOVE WINDOW TREATMENTS & ASSOCIATED COMPONENTS. PATCH ANYREMAINING HOLES IN THE MTL FRAMING W/ COLOR MATCHED CAULK.5 REMOVE SHEET VINYL FLOOR FINISH & ASSOCIATED WALL BASE. REFER TOABATEMENT DRAWINGS. PREP FLOOR TO RECEIVE SCHEDULED FINISHES.6 REMOVE CPT FLOOR FINISH. SHEET VINYL FLOOR FINISH (BELOW CPT) &ASSOCIATED WALL BASE REMOVAL. REFER TO ABATEMENT DRAWINGS.PREP FLOOR FOR SCHEDULED FINISHES.7 REMOVE ACT CEILING & ASSOCIATED COMPONENTS. EXISTING WOODBLOCKING AT CEILING EDGES TO REMAIN.8 REMOVE ACT CEILING & ASSOCIATED COMPONENTS.9 REMOVE MTL COAT RACK/SHELF. PATCH AND REPAIR GYP BD TO RECEIVESCHEDULED FINISH.10 REMOVE CHALKBOARD & ASSOCIATED COMPONENTS. PATCH AND REPAIRGYP BD PARTITION TO RECEIVE SCHEDULED FINISH.11 REMOVE TACKBOARD & ASSOCIATED COMPONENTS. PATCH AND REPAIRGYP BD PARITION TO RECEIVE SCHEDULED FINISH.12 REMOVE WALL CABINET & ASSOCIATED COMPONENTS. PATCH AND REPAIRGYP BD PARTITION TO RECEIVE SCHEDULED FINISH.13 REMOVE MTL CHASE ENCLOSURE.14 REMOVE WD STUD AND PLYWOOD PARTITION IN ITS ENTIRETY.15 REMOVE PEGBOARD16 REMOVE WD DOOR & FRAME17 REMOVE ALL LAB CASEWORK IN ITS ENTIRETY. COORDINATE WITHABATEMENT DRAWINGS18 REMOVE MTL STUD AND GYP BD PARTITION. PREP TO RECEIVE SCHEDULEDWINDOW.19 REMOVE FUME HOOD. REFER TO ABATEMENT DRAWINGS.20 REMOVE COUNTERTOP. REFER TO ABATEMENT DRAWINGS.21 CAREFULLY REMOVE AND SALVAGE WOOD UPPER CABINETS FORREINSTALLATION IN ACID WASH.22 REMOVE MTL STUD AND GYP BOARD PARTITION. PATCH AND REPAIRWALLS AND FLOORS TO RECEIVE SCHEDULED FINISHES.23 REMOVE DOOR, FRAME, AND RELATED HARDWARE. TURN LOCK CYLINDERSOVER TO OWNER.24 REMOVE PORTION OF MTL STUD AND GYP BOARD PARTITION FORSCHEDULED DOOR. PATCH AND REPAIR PARTITION TO RECEIVESCHEDULED FINISHES.25 REMOVE WALL MOUNTED PEGBOARD. PATCH AND REPAIR GYP BDPARTITION TO RECEIVE SCHEDULED FINISH.26 REMOVE WALL MOUNTED FIRE EXTINGUISHER BRACKET. PATCH ANDREPAIR GYP BD PARTITION TO RECEIVE SCHEDULED FINISH. SALVAGE ANDTURN OVER FIRE EXTINGUISHER TO OWNER.27 REMOVE WALL MOUNTED COAT RACK. PATCH AND REPAIR GYP BDPARTITION TO RECEIVE SCHEDULED FINISH.28 REMOVE WALL MOUNTED PENCIL SHARPENER AND WD BLOCKING. PATCHAND REPAIRGYP BD PARTITION TO RECEIVE SCHEDULED FINISH.29 REMOVE WALL MOUNTED WD BLOCKING. PATCH AND REPAIR GYP BDPARTITION TO RECEIVE SCHEDULED FINISH.30 REMOVE WALL MOUNTED SHELVING UNIT (+/- 10'-0" LONG) AND ALLASSOCIATED COMPONENTS. PATCH AND REPAIR GYP BD PARTITION TORECEIVE SCHEDULED FINISH.31 REMOVE METAL SCREW EYES. PATCH AND REPAIR GYP BD PARTITION TORECEIVE SCHEDULED FINISH.32 SALVAGE HEAVY STONE BELOW COUNTERTOP AND RELOCATE TO E334.PLAN KEY NOTESNO.DESCRIPTION1 GAS CYLINDER RACK - BOD: USA SAFETY BR2X2FS; FOR OWNER-PROVIDED(1) HE, (1) P5 AND (2) ULTRA-PURE AIR GAS BOTTLES. SEE PLUMBINGDRAWINGS FOR MANIFOLD ASSEMBLY AND PIPING TO EQUIPMENT2 PAINTED STL BASE CABINETS, WALL CABINETS (WHERE SHOWN) & EPOXYCOUNTERTOP. SEE INTERIOR ELEVATIONS FOR DETAILS.3 24"W X 30"H PEG BOARD WITH SST DRIP TRAY AT 42" AFF TO BOTTOM.4 DROP-IN EPOXY RESIN SINK, SK-A, 18" X 15" X 7.9"5 DROP-IN EPOXY RESIN SINK, SK-B, 18" X 15" X 5"6 DROP-IN EPOXY RESIN SINK, SK-C, 14" X 10" X 6.3"7 DROP-IN EPOXY RESIN SINK, SK-D, 18" X 15" X 7.9"8 DROP-IN EPOXY RESIN SINK, SK-E, 18" X 15" X 15.13"9 DROP-IN EPOXY RESIN SINK, SK-F, 18" X 15" X 5"10 DROP-IN EPOXY RESIN SINK, SK-G, 25" X 15" X 17.75"11 4'-0" X 4'-0" TACKBOARD12 WINDOW TREATMENTS, WT-1. EXISTING WINDOWS ARE +/- 4'-9" HIGH, VIF.WIDTHS AS INDICATED ON FLOOR PLANS.13 FROSTED VINYL FILM TO EXISTING DOOR SIDELITES. APPROX 24SF.14 COMPRESSED AIR CONNECTION, REFER TO PLUMBING DRAWINGS15 NATURAL GAS CONNECTION, SEE PLUMBING DRAWINGS16 2'-6" W X 4'-0"H MARKERBOARD17 (1) LAYER OF 1/2" GYP BD ON ROOM SIDE OF PARTITION. ON CORRIDORSIDE OF PARTITION, INFILL REVEAL AT WALL BASE W/ (1) LAYER OF 1/2" GYPBD & PROVIDE 4" RESILIENT BASE. ALIGN FACE OF GYP BD W/ EXISTINGGYP BD LAYER ABOVE. MATCH COLOR OF RESILIENT BASE TO EXISTINGBASE IN CORRIDOR. CORRIDOR SIDE OF WALL TO RECEIVE PAINT TOMATCH EXISTING CORRIDOR PAINT.18 WD BASE CABINETS & EPOXY COUNTERTOP. SEE INTERIOR ELEVATIONSFOR DETAILS19 (2) GAS CYLINDER WALL-MOUNTED SAFETY BRACKETS (BOD: USA SAFETYMODEL #GB300FS); FOR OWNER PROVIDED (1) P5 SIZE 200 AND (2) H2 SIZE80 GAS BOTTLES. SEE INTERIOR ELEVATIONS FOR MOUNTING HEIGHTS OFTHE (2) SAFETY BRACKETS. SEE PLUMBING DRAWINGS FOR PIPING ANDMANIFOLD.20 WALL MOUNTED ADJUSTABLE REAGENT SHELVING. SEE INTERIORELEVATIONS FOR DETAILS.21 ADJUSTABLE REAGENT SHELVING MOUNTED TO PAINTED STEEL UPRIGHTS.SEE INTERIOR ELEVATIONS FOR DETAILS.22 30"W X 30"H PEG BOARD WITH SST DRIP TRAY AT 42" AFF TO BOTTOM.23 COMPUTER WORKSTATION (OF/OI)24 18"W X 30"H PEGBOARD WITH SST DRIP TRAY AT 42" AFF TO BOTTOM.25 PAINT EXPOSED CONC COLUMN WITH EPOXY PAINT26 12"D X 4'-0"L METRO SHELVING (OF/OI)27 4'-0"H X 8'-0"W SLATWALL AT 2'-8" AFF TO BOTTOM.28 GAS CYLINDER RACK - BOD: USA SAFETY BR2X2FS; FOR OWNER-PROVIDED(1) H2, (1) C2H2 AND (2) ULTRA-PURE AIR GAS BOTTLES. SEE PLUMBINGDRAWINGS FOR MANIFOLD ASSEMBLY AND PIPING TO EQUIPMENT.29 INSTALL SALVAGED WD WALL CABNIETS FROM E304.30 CAPTURE HOOD, REFER TO MECHANICAL DRAWINGS31 SMOKE GASKETING AT EXISTING DOOR.32 PATCH HOLE IN CONCRETE SLAB AT PIPING REMOVAL. PREPARE TORECEIVED SCHEDULED FINISH.33 GAS CYLINDER WALL-MOUNTED SAFETY BRACKET (BOD:USA SAFETYMODEL #GB200FS); FOR OWNER PROVIDED (1) H2 SIZE 200 GAS BOTTLEAND (1) FUTURE GAS BOTTLE. SEE INTERIOR ELEVATION FOR MOUNTINGHEIGHT. SEE PLUMBING DRAWINGS FOR PIPING.1/2" = 1'-0"4Detail - Ceiling Edge @ Curtainwall, Typ.#SHOWN AS:#SHOWN AS:N1/2" = 1'-0"5Detail - Top of Partition Infill - Lab1/2" = 1'-0"6Detail - Top of Partition Infill - Office E303 FEDF15161718E323E321E334E318E318A222223232323228585852444611291272830131171717313125199171726171317116TYP.DF15161718OFFICEE321COMPUTATIONAL LABE323(LAB CART, NIC)COAT RACKBALANCES ON MARBLE SLAB TABLEN2ULTRA PURE AIRSINKACCESSIBLETALL STORAGEKNEE SPACEKNEE SPACEKNEE SPACEKNEE SPACEAJ22A'A'E'F'G'B'C'J'J'H'D'H-2SOIL ROOME318VESTE334BACID WASHE334AOPEN LABE3341829829322122028(LAB CART, NIC)22073E318E318AE334BE334AE3341212E321E3232' - 0"VIF+/- 5' - 0 1/2"5' - 0"A3A3AA3AA3A3U3U6U8107KNEE SPACEA-421A-421A-4213A-42157A-421468921171717EXTENT OF INFILL AT WALL BASE, RESILIENT BASE INSTALLATION AND PAINTINGEXTENT OF INFILL AT WALL BASE RESILIENT BASE INSTALLATION AND PAINTING24CLEAR2' - 6 3/4"ELECTRICAL PANEL, SEE ELECTRICAL DRAWINGS5' - 0"ALIGN25193' - 1"2627VIF+/- 5' - 0 1/2"2' - 0"A-4217OPPCOAT RACK30CANGNGCACA NGCA NG31( 19' - 0 3/4" )( 9' - 3" )( 14' - 11" )11' - 0"ALIGN2' - 6"( 7' - 5" )( 19' - 7 3/4" )( 9' - 7 1/4" )( 9' - 7 1/4" )( 7' - 8 1/4" )2' - 6"2' - 6"2' - 6"( 20' - 4" )2A-6011A-601VIF3' - 10"VIF4' - 10"VIF3' - 10"VIF4' - 10"VIF8' - 8"VIF8' - 8"141514151415141532K'C2H22' - 1"2' - 6"ALIGNHOLD "U3" AND "U6" TIGHT TO COLUMNPATCH WALL AT DRYING RACK REMOVAL, PREPARE FOR NEW FINISHGENERAL NOTES:ALL FLOORS, WALLS, CEILINGS, AND OTHER SURFACES THAT ARE TO REMAIN ARE TO BE PATCHED, REPAIRED, AND REFINISHED PRIOR TO FINISH INSTALLATION. ALL SURFACES ARE TO BE RESTORED TO THEIR ORIGINAL CONDITION AND/OR MATCH THE ADJACENT SURFACES.FIRESTOP ALL FLOOR PENETRATIONS (USED/UNUSED/ABANDONED) WITH 2 HR UL LISTED PENETRATION FIRESTOPPING.OF/CI: OWNER FURNISHED, CONTRACTOR INSTALLEDOF/OI: OWNER FURNISHED, OWNER INSTALLEDDIMENSIONS WITHIN PARENTHESES, (X' -X"), HAVE BEEN PROVIDED FOR REFERENCE ONLYSEE A-603 FOR FUME HOOD (" ") AND OF/OI LAB EQUIPMENT (" ")1.2.3.4.5.XXEVERY ATTEMPT HAS BEEN MADE TO DOCUMENT PERTINENT EXISTING CONDITIONS FROM EXISTING SURVEYS, DRAWINGS AND LIMITED FIELD INSPECTION. PRIOR TO THE SUBMISSION OF BIDS, CONTRACTORS SHALL WALK THE SITE AND SATISFY THEMSELVES TO EXISTING VISUAL CONDITIONS. THE ARCHITECT SHALL BE CONSULTED WHEN ANY QUESTION ARISES RELATIVE TO MATERIALS AND CONDITIONS NOT SPECIFICALLY SHOWN OR SPECIFIED.ALL EXISTING WORK (CEILING, FLOORS, WALLS, FINISHES, ETC.) DISTURBED BY NEW CONSTRUCTION SHALL BE PATCHED AND REFINISHED. PATCHING AND FINISH WORK IS THE REPAIR WORK REQUIRED TO RESTORE SURFACES TO THE ORIGINAL CONDITION AND/ OR MATCHING THE ADJACENT SURFACES. MISCELLANEOUS FINISH REQUIREMENTS TO WALL, FLOOR AND CEILING IN AREAS AFFECTED BY DEMOLITION HAVE NOT BEEN TOTALLY INCORPORATED INTO THE ROOM FINISH SCHEDULE. REFER TO THE DEMOLITION , FLOOR AND REFLECTED CEILING PLANS FOR ADDITIONAL CUTTING , PATCHING AND REFINISHING WORK SCOPE.CONTRACTOR(S) SHALL COORDINATE ALL WORK WITH HAZARDOUS MATERIALS ABATEMENT WORK. SOME ITEMS ON DEMOLITION PLAN WILL REQUIRE REMOVAL PRIOR TO START OF ABATEMENT WORK.THE EXISTING FIRE-RESISTANT CONSTRUCTION MUST BE MAINTAINED OR MADE TO COMPLY WITH THE REQUIREMENTS AS ESTABLISHED BY THIS CONTRACT. SEE THE CODE COMPLIANCE PLANS FOR THE FIRE RESISTANT RATINGS OF EXISTING AND NEW CONSTRUCTION.CARE SHALL BE TAKEN TO LIMIT IMPACT OF CONSTRUCTION ON THE SURROUNDING OCCUPANTS AND OPERATIONS DURING THE PROJECT. SAFE LEGAL PASSAGES SHALL BE PROVIDED FOR ALL BUILDING OCCUPANTS DURING ALL THE PHASES OF THIS PROJECT.WHEN EXISTING CONSTRUCTION WHICH IS TO REMAIN IS DAMAGED DURING THE COURSE OF CONSTRUCTION AS A RESULT OF CONTRACTOR'S WORK, IT SHALL BE REPAIRED AND/OR REPLACED WITH SIMILAR OR LIKE MATERIALS, SUBJECT TO ARCHITECT'S APPROVAL AND WITHOUT COMPENSATION.'REMOVE' IS DEFINED AS DETACH FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSE OF OFF-SITE UNLESS INDICATED TO BE SALVAGED OR REINSTALLED1.2.3.4.5.6.7.GENERAL DEMOLITION NOTES:These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions3/15/2021 3:42:29 PMBIM 360://20636.00 Cornell Corson Hall E303-E347/Cornell Corson Hall E303 E304 E305 E347 Lab and Office Renovation.rvt20636.00CWJPartial Third FloorPlans - E318-E334CWJCREA-102100% ConstructionDocumentsCornell UniversityCorson Hall Third FloorLaboratory & Office RenovationIthaca, NYMarch 5, 20211/4" = 1'-0"1Partial Third Floor Demolition Plan - E318-E3341/4" = 1'-0"2Partial Third Floor Plan - E318-E334N#SHOWN AS:#SHOWN AS:PLAN KEY NOTES -NO.DESCRIPTION1 GAS CYLINDER RACK - BOD: USA SAFETY BR2X2FS; FOR OWNER-PROVIDED (1) HE, (1) P5 AND (2) ULTRA-PURE AIR GASBOTTLES. SEE PLUMBING DRAWINGS FOR MANIFOLD ASSEMBLY AND PIPING TO EQUIPMENT2 PAINTED STL BASE CABINETS, WALL CABINETS (WHERE SHOWN) & EPOXY COUNTERTOP. SEE INTERIOR ELEVATIONS FORDETAILS.3 24"W X 30"H PEG BOARD WITH SST DRIP TRAY AT 42" AFF TO BOTTOM.4 DROP-IN EPOXY RESIN SINK, SK-A, 18" X 15" X 7.9"5 DROP-IN EPOXY RESIN SINK, SK-B, 18" X 15" X 5"6 DROP-IN EPOXY RESIN SINK, SK-C, 14" X 10" X 6.3"7 DROP-IN EPOXY RESIN SINK, SK-D, 18" X 15" X 7.9"8 DROP-IN EPOXY RESIN SINK, SK-E, 18" X 15" X 15.13"9 DROP-IN EPOXY RESIN SINK, SK-F, 18" X 15" X 5"10 DROP-IN EPOXY RESIN SINK, SK-G, 25" X 15" X 17.75"11 4'-0" X 4'-0" TACKBOARD12 WINDOW TREATMENTS, WT-1. EXISTING WINDOWS ARE +/- 4'-9" HIGH, VIF. WIDTHS AS INDICATED ON FLOOR PLANS.13 FROSTED VINYL FILM TO EXISTING DOOR SIDELITES. APPROX 24SF.14 COMPRESSED AIR CONNECTION, REFER TO PLUMBING DRAWINGS15 NATURAL GAS CONNECTION, SEE PLUMBING DRAWINGS16 2'-6" W X 4'-0"H MARKERBOARD17 (1) LAYER OF 1/2" GYP BD ON ROOM SIDE OF PARTITION. ON CORRIDOR SIDE OF PARTITION, INFILL REVEAL AT WALL BASE W/(1) LAYER OF 1/2" GYP BD & PROVIDE 4" RESILIENT BASE. ALIGN FACE OF GYP BD W/ EXISTING GYP BD LAYER ABOVE. MATCHCOLOR OF RESILIENT BASE TO EXISTING BASE IN CORRIDOR. CORRIDOR SIDE OF WALL TO RECEIVE PAINT TO MATCHEXISTING CORRIDOR PAINT.18 WD BASE CABINETS & EPOXY COUNTERTOP. SEE INTERIOR ELEVATIONS FOR DETAILS19 (2) GAS CYLINDER WALL-MOUNTED SAFETY BRACKETS (BOD: USA SAFETY MODEL #GB300FS); FOR OWNER PROVIDED (1) P5SIZE 200 AND (2) H2 SIZE 80 GAS BOTTLES. SEE INTERIOR ELEVATIONS FOR MOUNTING HEIGHTS OF THE (2) SAFETYBRACKETS. SEE PLUMBING DRAWINGS FOR PIPING AND MANIFOLD.20 WALL MOUNTED ADJUSTABLE REAGENT SHELVING. SEE INTERIOR ELEVATIONS FOR DETAILS.21 ADJUSTABLE REAGENT SHELVING MOUNTED TO PAINTED STEEL UPRIGHTS. SEE INTERIOR ELEVATIONS FOR DETAILS.22 30"W X 30"H PEG BOARD WITH SST DRIP TRAY AT 42" AFF TO BOTTOM.23 COMPUTER WORKSTATION (OF/OI)24 18"W X 30"H PEGBOARD WITH SST DRIP TRAY AT 42" AFF TO BOTTOM.25 PAINT EXPOSED CONC COLUMN WITH EPOXY PAINT26 12"D X 4'-0"L METRO SHELVING (OF/OI)27 4'-0"H X 8'-0"W SLATWALL AT 2'-8" AFF TO BOTTOM.28 GAS CYLINDER RACK - BOD: USA SAFETY BR2X2FS; FOR OWNER-PROVIDED (1) H2, (1) C2H2 AND (2) ULTRA-PURE AIR GASBOTTLES. SEE PLUMBING DRAWINGS FOR MANIFOLD ASSEMBLY AND PIPING TO EQUIPMENT.29 INSTALL SALVAGED WD WALL CABNIETS FROM E304.30 CAPTURE HOOD, REFER TO MECHANICAL DRAWINGS31 SMOKE GASKETING AT EXISTING DOOR.32 PATCH HOLE IN CONCRETE SLAB AT PIPING REMOVAL. PREPARE TO RECEIVED SCHEDULED FINISH.33 GAS CYLINDER WALL-MOUNTED SAFETY BRACKET (BOD:USA SAFETY MODEL #GB200FS); FOR OWNER PROVIDED (1) H2 SIZE200 GAS BOTTLE AND (1) FUTURE GAS BOTTLE. SEE INTERIOR ELEVATION FOR MOUNTING HEIGHT. SEE PLUMBING DRAWINGSFOR PIPING.DEMOLITION KEY NOTES -NO.DESCRIPTION1 REMOVE SHELVING AND WALL STANDARDS IN THEIR ENTIRETY. PATCH AND REPAIR GYP BD PARTITION TORECEIVE SCHEDULED FINISH.2 REMOVE WD DOOR, FRAME & ASSOCIATED COMPONENTS. TURN LOCK CYLINDERS OVER TO OWNER. PREPAREOPENING TO RECEIVE SCHEDULED DOOR. MARBLE THRESHOLD TO REMAIN.3 REMOVE DOOR, FRAME, & ASSOCIATED COMPONENTS INCLUDING SHELVES INSTALLED ON DOOR PANEL. TURNLOCK CYLINDERS OVER TO OWNER.4 REMOVE WINDOW TREATMENTS & ASSOCIATED COMPONENTS. PATCH ANY REMAINING HOLES IN THE MTLFRAMING W/ COLOR MATCHED CAULK.5 REMOVE SHEET VINYL FLOOR FINISH & ASSOCIATED WALL BASE. REFER TO ABATEMENT DRAWINGS. PREP FLOORTO RECEIVE SCHEDULED FINISHES.6 REMOVE CPT FLOOR FINISH. SHEET VINYL FLOOR FINISH (BELOW CPT) & ASSOCIATED WALL BASE REMOVAL.REFER TO ABATEMENT DRAWINGS. PREP FLOOR FOR SCHEDULED FINISHES.7 REMOVE ACT CEILING & ASSOCIATED COMPONENTS. EXISTING WOOD BLOCKING AT CEILING EDGES TO REMAIN.8 REMOVE ACT CEILING & ASSOCIATED COMPONENTS.9 REMOVE MTL COAT RACK/SHELF. PATCH AND REPAIR GYP BD TO RECEIVE SCHEDULED FINISH.10 REMOVE CHALKBOARD & ASSOCIATED COMPONENTS. PATCH AND REPAIR GYP BD PARTITION TO RECEIVESCHEDULED FINISH.11 REMOVE TACKBOARD & ASSOCIATED COMPONENTS. PATCH AND REPAIR GYP BD PARITION TO RECEIVESCHEDULED FINISH.12 REMOVE WALL CABINET & ASSOCIATED COMPONENTS. PATCH AND REPAIR GYP BD PARTITION TO RECEIVESCHEDULED FINISH.13 REMOVE MTL CHASE ENCLOSURE.14 REMOVE WD STUD AND PLYWOOD PARTITION IN ITS ENTIRETY.15 REMOVE PEGBOARD16 REMOVE WD DOOR & FRAME17 REMOVE ALL LAB CASEWORK IN ITS ENTIRETY. COORDINATE WITH ABATEMENT DRAWINGS18 REMOVE MTL STUD AND GYP BD PARTITION. PREP TO RECEIVE SCHEDULED WINDOW.19 REMOVE FUME HOOD. REFER TO ABATEMENT DRAWINGS.20 REMOVE COUNTERTOP. REFER TO ABATEMENT DRAWINGS.21 CAREFULLY REMOVE AND SALVAGE WOOD UPPER CABINETS FOR REINSTALLATION IN ACID WASH.22 REMOVE MTL STUD AND GYP BOARD PARTITION. PATCH AND REPAIR WALLS AND FLOORS TO RECEIVESCHEDULED FINISHES.23 REMOVE DOOR, FRAME, AND RELATED HARDWARE. TURN LOCK CYLINDERS OVER TO OWNER.24 REMOVE PORTION OF MTL STUD AND GYP BOARD PARTITION FOR SCHEDULED DOOR. PATCH AND REPAIRPARTITION TO RECEIVE SCHEDULED FINISHES.25 REMOVE WALL MOUNTED PEGBOARD. PATCH AND REPAIR GYP BD PARTITION TO RECEIVE SCHEDULED FINISH.26 REMOVE WALL MOUNTED FIRE EXTINGUISHER BRACKET. PATCH AND REPAIR GYP BD PARTITION TO RECEIVESCHEDULED FINISH. SALVAGE AND TURN OVER FIRE EXTINGUISHER TO OWNER.27 REMOVE WALL MOUNTED COAT RACK. PATCH AND REPAIR GYP BD PARTITION TO RECEIVE SCHEDULED FINISH.28 REMOVE WALL MOUNTED PENCIL SHARPENER AND WD BLOCKING. PATCH AND REPAIRGYP BD PARTITION TORECEIVE SCHEDULED FINISH.29 REMOVE WALL MOUNTED WD BLOCKING. PATCH AND REPAIR GYP BD PARTITION TO RECEIVE SCHEDULED FINISH.30 REMOVE WALL MOUNTED SHELVING UNIT (+/- 10'-0" LONG) AND ALL ASSOCIATED COMPONENTS. PATCH ANDREPAIR GYP BD PARTITION TO RECEIVE SCHEDULED FINISH.31 REMOVE METAL SCREW EYES. PATCH AND REPAIR GYP BD PARTITION TO RECEIVE SCHEDULED FINISH.32 SALVAGE HEAVY STONE BELOW COUNTERTOP AND RELOCATE TO E334. 1019E_E412COMPUTATIONAL LABE323OFFICEE32118' -6"28' -6"18' -6"18' -6"E8' -6"E8' -6"E7' -11 1/2"AJ12A-103OPEN LABE334ACID WASHE334ASOIL ROOME318VESTE334BOFFSET TOP OF PARTITION AROUND EXISTING DUCT ABOVE CEILING.3A-103MODIFY EXISTING ACOUSTICAL CEILING IN SHADED AREA TO ACCOMMODATE PARTITION INFILL. REWORK GRID AND TILES AND INSTALL NEW PERIMETER EDGE TRIM.METAL STUD & GYP BD INFILL AT TOP OF EXISTING PARTITIONEQEQEQEQEQEQEQEQEQEQRCP LEGENDGYP BD CLG OR SOFFITCEILING GRIDEXIT LIGHT2'X4' LED FIXTURE2'X2' LED FIXTURE1'X4' LED FIXTURESPRINKLER HEADSUPPLY DIFFUSER, REFER TO MECHANICAL DRAWINGS RETURN AIR GRILLE, REFER TO MECHANICAL DRAWINGS 12X2 ACT-1CEILING TYPESGYP BD CLG OR SOFFIT, PT2EXISTING CEILING TO REMAINEVERIFY THICKNESS IN FIELDVIF+/- 4' - 3"DEFLECTION HEADBACKER ROD & SEALANT, EA SIDESOUND ATTENUATION BLANKETS1/2" GYP BD ON 2 1/2" MTL STUDS @ 16" OCANGLE MOLDING, EA SIDELINE OF STRUCTURE3 5/8" x 20GA MTL STUD DIAGONAL BRACING @ 4'-0" OC MAXLIGHT GAUGE CLIP ANGLEEXISTING 2 1/2" MTL STUD PARTITION W/ 1/2" GYP BD EA. SIDEALIGN FACE OF GYP BD, EA SIDE. SHIM AS REQUIRED.MODIFIED EXIST CEILING TILEMODIFIED EXISTING CEILING TILEEXISTING TO REMAIN DUCT,VERIFY LOCATION IN FIELD4"4"GYPSUM BD OFFSET TO OCCUR ABOVE ACT CEILINGSCHEDULED PARTITIONSCHEDULED CEILINGVIF+/- 4' - 3"LINE OF STRUCTURE3 5/8" x 20GA MTL STUD DIAGONAL BRACING @ 4'-0" OC MAXLIGHT GAUGE CLIP ANGLESCHEDULED CEILINGANGLE MOLDING, EA SIDEThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions3/15/2021 3:42:30 PMBIM 360://20636.00 Cornell Corson Hall E303-E347/Cornell Corson Hall E303 E304 E305 E347 Lab and Office Renovation.rvt20636.00CWJPartial Third FloorReflected Ceiling Plan -E318-E334CWJCREA-103100% ConstructionDocumentsCornell UniversityCorson Hall Third FloorLaboratory & Office RenovationIthaca, NYMarch 5, 20211/4" = 1'-0"1Partial Third Floor Reflected Ceiling Plan - E318-E334N1/2" = 1'-0"2Detail - Top of Partition Infill - Office E3211/2" = 1'-0"3Detail - Partition Offset at Existing Duct DF15161718REINSTALL (3) SALVAGED METAL WALL CABINETSS1S1MODIFY EXISTING SUSPENDED ACOUSTICAL TILE CEILING TO ACCOMMODATE CHASE A-1046PROVIDE 4" RUBBER BASE MATCHED TO EXISTING WALL BASEE412E421AE416E416AE412BE412CE400CE440DF15161718MODIFY EXISTING BALLASTED INVERTED EPDM ROOF TO ACCOMMODATE OPENING AND 12" H PREMANUFACTURED ROOF CURB FOR EXHAUST FAN. VERIFY OPENING SIZE WITH EXHAUST FAN MFR. REFER TO HAZARDOUS MATERIALS DRAWINGS FOR ACM REMOVALS. SEE MECHANICAL DRAWINGS FOR EXHAUST FAN DETAILS.EXISTING BALLASTED INVERTED EPDM ROOF+/- 1' - 4 1/4"+/- 1' - 4 1/4"7A-104DF15161718CAREFULLY REMOVE AND SALVAGE (3) METAL WALL CABINETS FOR REINSTALLATION. PATCH AND REPAIR GYPSUM BOARD PARTITION. PAINT TO MATCH ADJACENT WALL SURFACE.REFER TO HAZARDOUS MATERIALS DRAWINGS FOR FLOORING AND MASTIC REMOVAL FOR NEW DUCT OPENING. REFER TO MECHANICAL DRAWINGS FOR DETAILS.E412E421AE416E416AE412BE412CE400CE440DF15161718E240E236AE236E200CE223E221E216AE216E212SHADED AREAS INDICATE APPROXIMATE AREA OF EXISTING ACOUSTICAL TILE CEILING TO ACCOMMODATE PLUMBING WORK. REMOVE AND REPLACE ACOUSTICAL CEILING TILES AS REQUIRED TO ACCOMMODATE PLUMBING WORK. PROVIDE NEW MATERIAL AS NECESSARY TO REPLACE DAMAGED COMPONENTS.+/- 6' - 6"+/- 3' - 0"+/- 3' - 0"+/- 3' - 0"+/- 9' - 0"+/- 14' - 2"+/- 4' - 0"+/- 10' - 11"+/- 3' - 0"+/- 6' - 0"+/- 10' - 8"+/- 4' - 0"+/- 3' - 1"ACDF1213E202AE202BE202E205E203SHADED AREAS INDICATE APPROXIMATE AREA OF EXISTING ACOUSTICAL TILE CEILING TO ACCOMMODATE PLUMBING WORK. REMOVE AND REPLACE ACOUSTICAL CEILING TILES AS REQUIRED TO ACCOMMODATE PLUMBING WORK. PROVIDE NEW MATERIAL AS NECESSARY TO REPLACE DAMAGED COMPONENTS.+/- 9' - 6"+/- 3' - 0"2-PLY SBS MODIFIED BITUMEN MEMBRANE FLASHINGUP SIDES AND OVER CURB EXISTING +/-12" THICK CONCRETE ROOF DECKINSULATEDPREFABRICATED CURBMIN1' - 0"REMOVE PORTION OF EXISTING INVERTED ROOF MEMBRANE ASSEMBLY. REFER TO HAZARDOUS MATERIALS DRAWINGS FOR REMOVAL OF FELT SLIP AND 3-PLY MOPPINGS OF FELT AND ASPHALT. INVERTED ROOF MEMBRANE ASSEMBLY COMPONENTS SHALL MATCH EXISTING AND METHOD OF APPLICATIONROOFTOPEQUIPMENTEXISTING INVERTEDROOF MEMBRANE SYSTEMA-1047AEXISTING DRY APPLIED, LOOSE LAID FELT SLIP SHEETEXISTING 3-PLY MOPPINGS OF FELT AND ASPHALTEXISTING RIGID PROTECTION BOARDEXISTING 2.5" EXTRUDED POLYSTYRENE INSULATIONEXISTING ROUNDED STONE BALLASTCANT1' - 0"2"AT FIRE -RATED PARTITIONS:CONSTRUCT DETAIL IN ACCORDANCE WITH U.L. LISTED FIRE-RESISTANT JOINT SYSTEMS (HW-D). PROVIDE DEFLECTION TRACK ASSEMBLIES, FORMING/ FILL MATERIALS AS REQUIRED BY APPROVED JOINT SYSTEMPACKING MATERIALFILL MATERIAL/SEALANTBOND BREAKER TAPEDEFLECTION TRACK3"3"6" WIDE LIQUID FLASHING STRIP (BOD: SOPREMA ALSAN FLASHING)GASKETED FASTENERS..050" PREFIN ALUMCOUNTERFLASHINGROOF MEMBRANE"S1" SHAFTWALL ASSEMBLY WITH UL-RATED HEAD OF WALL ASSEMBLY FROM FLOOR TO UNDERSIDE OF ROOF DECK ABOVE. LINER PANEL FACING EXISTING PARTITIONS. TAPE AND FINISH INSIDE OF SHAFT.DUCT, SEE MECHANICAL DRAWINGS"S1" SHAFTWALL ASSEMBLY WITH UL-RATED HEAD OF WALL ASSEMBLY FROM FLOOR TO UNDERSIDE OF ROOF DECK ABOVE. LINER PANEL FACING INSIDE OF SHAFT. TAPE AND FINISH ROOM SIDE.EXISTING PARTITION TO CEILINGCLEAR1' - 2"CLEAR1' - 2"These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions3/15/2021 3:42:32 PMBIM 360://20636.00 Cornell Corson Hall E303-E347/Cornell Corson Hall E303 E304 E305 E347 Lab and Office Renovation.rvt20636.00CWJPartial PlansCWJCREA-104100% ConstructionDocumentsCornell UniversityCorson Hall Third FloorLaboratory & Office RenovationIthaca, NYMarch 5, 20211/8" = 1'-0"4Partial Fourth Floor Plan1/8" = 1'-0"5Partial Roof PlanN1/8" = 1'-0"3Partial Fourth Floor Demolition Plan1/8" = 1'-0"1Partial Second Floor Plan - Rm 216-2361/8" = 1'-0"2Partial Second Floor Plan - Rm 202-2053" = 1'-0"7Prefabricated Curb Detail6" = 1'-0"7AEnlarged Detail of Top of Curb3/4" = 1'-0"6Enlarged Floor Plan at Chase 3/4"2' - 6"2' - 0"5' - 0"2' - 0"1 5/8"3' - 6"3' - 6"SCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELSTACKBOARD(4'-0" X 4'-0")EPOXY COUNTERTOP, BACK AND SIDE SPLASH AT PARTITION, TYP12"D OUTER LIP REAGENT SHELVING ON WALL RAIL ASSEMBLYPAINTED STL CABINETS & DRAWERS4"2' - 6"7' - 0"3' - 0"7A-5018A-501SCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELSEPOXY COUNTERTOP, BACK AND SIDE SPLASH AT PARTITION, TYPPAINTED STL CABINETS & DRAWERS4' - 3"2' - 10"3/4"5' - 6"STL CLOSURE PANEL @ KNEESPACEPAINTED STL APRONEPOXY COUNTERTOP, BACK AND SIDE SPLASH AT PARTITION, TYPSCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELS12"D OUTER LIP W/ 12"D INNER REAGENT SHELVING ON PAINTED STL UPRIGHTS30"W X 30"H PEG BOARD W/ SST DRIP TROUGH14A-5014"3' - 0"2' - 11 5/8"3' - 0"2' - 6"3' - 0"7' - 1"3' - 0"3' - 6"3' - 0"2' - 6"13' - 0 5/8"EPOXY COUNTERTOP, BACK AND SIDE SPLASH AT PARTITION, TYPSCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELS12"D OUTER LIP W/ 12"D INNER REAGENT SHELVING ON PAINTED STL UPRIGHTS30"W X 30"H PEG BOARD W/ SST DRIP TROUGHSTL CLOSURE PANEL @ KNEESPACEPAINTED STL CABINETS & DRAWERS12"D OUTER LIP REAGENT SHELVING ON WALL RAIL ASSEMBLY14A-501CANG8A-5017A-50116A-501SIM4 7/8"1' - 9"3' - 0"2' - 0"1"3' - 0"4"2' - 10"2' - 0"3' - 0"3' - 0"18"D PAINTED STL CABINET W/ OPEN SHELVES BEYOND (FACING KNEE SPACE)TOP EDGE OF BACKSPLASH @ 3'-4" AFFALIGNSCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELSEPOXY COUNTERTOP, BACK AND SIDE SPLASH AT PARTITION, TYP12"D OUTER LIP REAGENT SHELVING ON WALL RAIL ASSEMBLY18"D PAINTED STL CABINETS & DRAWERS3' - 0"PAINTED STL CABINETS & CLOSURE PANELUPRIGHTS, SHELVING & PEG BOARDS BEYOND30"W X 48"H MARKER BOARD(L)NOTE: (L) DENOTES LOCKED DRAWER LOCATIONFLAMMABLE STORAGECANG9' - 1 1/8"9A-5017' - 1"E304A2"2' - 6"3' - 0"1' - 9"2' - 6"2' - 6"4"3' - 0"3' - 6"CAPTURE HOOD, REFER TO MECHANICAL DRAWINGSPAINTED STL CABINETS W/ SLIDING GLASS DOORSSCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELSEPOXY COUNTERTOP, BACK AND SIDE SPLASH AT PARTITION, TYPPAINTED STL CABINETS & DRAWERSSTL CLOSURE PANEL @ KNEESPACE3' - 6"2' - 7"7' - 0"1A-5012A-50112' - 6"SCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELSEPOXY COUNTERTOP, BACK AND SIDE SPLASH AT PARTITION, TYPPAINTED STL CABINETS & DRAWERS24"W X 30"H PEG BOARD W/ SST DRIP TROUGH1"2' - 0"2' - 8 1/4"4"3' - 0"3' - 6"6A-501SIM.13A-501ACCESSIBLE MOTORIZED BASE STANDCOMBINATION FUME HOODPAINTED STEEL CABINETS W/ GLASS DOORSSCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELSEPOXY COUNTERTOP, BACKSPLASH AT PARTITION, TYP18"D PAINTED STL CABINET W/ OPEN SHELVES (FACING KNEE SPACE)2' - 6"2' - 6"2' - 7"2' - 11"2' - 10"1"5' - 0"1"2' - 10"3' - 0"7' - 0"2' - 11"12A-501PAINTED STL CABINET W/ OPEN SHELVES (FACING KNEE SPACE)OPEN BEHIND CASEWORK & UNDER FIN TUBE2' - 6"4"MARBLE SLAB BALANCE TABLE5' - 3"3/4"2' - 6"2' - 6"2' - 11"SCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELSEPOXY COUNTERTOP, BACKSPLASH AT PARTITION, TYPPAINTED STL CABINETS & DRAWERSSTEEL CLOSURE PANEL AT KNEESPACECORNER POST2' - 7"3' - 3"GAS CYLINDER BRACKET. PROVIDE WOOD BLOCKING.COAT RACKFUTURE GAS CYLINDER, NIC2A-501SIM4A-1011' - 9"1"4"3' - 0"8' - 8 1/2"OPEN TO CMU WALL AND PARTITION BEYOND AT KNEE SPACESCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELSEPOXY COUNTERTOP, BACK & SIDE SPLASH AT PARTITION & FIN TUBE COVERPAINTED STL CABINETS & DRAWERS(L)3' - 10 1/2"3' - 0"2A-5011A-501SIM.SIM.5' - 0"1' - 9"2' - 6"3' - 0"2"2' - 7"7' - 0"3' - 0"4"4' - 0"OPEN BEHIND CASEWORK & UNDER FIN TUBE12' - 7"PAINTED STL CABINETS W/ SLIDING GLASS DOORSSCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELSEPOXY COUNTERTOP, BACK AND SIDE SPLASH AT PARTITION, TYPPAINTED STL CABINETS & DRAWERSSTEEL CLOSURE PANEL AT KNEESPACE24"W X 30"H PEG BOARD W/ SST DRIP TROUGHGAS CYLINDER RACKCORNER POSTCA1A-5012A-501SIM13A-501SIMPAINTED STL CABINETS W/ GLASS DOORSSCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELSEPOXY COUNTERTOP, BACKSPLASH AT PARTITION, TYP12"D OUTER LIP REAGENT SHELVING ON WALL RAIL ASSEMBLY3' - 0"2' - 8 1/4"2' - 0"1"3' - 6"8A-5017A-5013' - 0"4"7' - 1"These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions3/15/2021 3:42:37 PMBIM 360://20636.00 Cornell Corson Hall E303-E347/Cornell Corson Hall E303 E304 E305 E347 Lab and Office Renovation.rvt20636.00CWJInterior Elevations -E303-E305CWJCREA-420100% ConstructionDocumentsCornell UniversityCorson Hall Third FloorLaboratory & Office RenovationIthaca, NYMarch 5, 20211/4" = 1'-0"1Interior Elevation - E304 - West A1/4" = 1'-0"2Interior Elevation - E304 - North1/4" = 1'-0"3Interior Elevation - E304 - East A1/4" = 1'-0"4Interior Elevation - E304 - West B1/4" = 1'-0"5Interior Elevation - E304 - South1/4" = 1'-0"6Interior Elevation - E304 - East B1/4" = 1'-0"7Interior Elevation - E304B - East1/4" = 1'-0"8Interior Elevation - E304B - South1/4" = 1'-0"10Interior Elevation - E305 - West1/4" = 1'-0"11Interior Elevation - E305 - North1/4" = 1'-0"13Interior Elevation - E305 - East1/4" = 1'-0"9Interior Elevation - E304B - West E3183' - 0"3' - 0"1' - 3"4"4"3' - 0"3' - 6"3' - 6"24" X 30" PEGBOARD W/ SST DRIP TROUGHSCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELS, TYP.EPOXY COUNTERTOP AND BACKSPLASH, TYPPAINTED STEEL CABINETS & DRAWERS12"D REAGENT SHELVING WITH SST RETAINER RODS ON WALL RAIL ASSEMBLY10' - 1"(L)3A-501SIM3' - 0"7' - 1"9' - 0"EPOXY COUNTERTOP AND BACKSPLASH, TYP4"3' - 0"1"PAINTED STEEL CABINETS & DRAWERSSCHEDULE BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONT AND SIDE PANELS, TYP.3' - 0"3' - 0"6"1A-501SIM.CAPTURE HOOD, REFER TO MECHANICAL DRAWINGS1' - 6"MIN. CLEAR2' - 6"3' - 6"1' - 5" CLEARACCESSIBLE MOTORIZED BASE STANDCOMBINATION FUME HOOD4"2' - 9"2' - 7"7' - 0"SCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELSEPOXY COUNTERTOP AND BACKSPLASHPAINTED STL CABINETS & DRAWERS4' - 0"3' - 6"1"1' - 3"PAINTED STEEL CABINETS W/ SLIDING GLASS DOORSEPOXY COUNTERTOP AND BACK AND SIDE SPLASH AT PARTITION7' - 8"FIXED PANEL WITH RECEPTACLES AND DATA JACKSDECK-MOUNTED COMPRESSED AIR AND NATURAL GAS SERVICE FITTING(L)5A-501SIM.1' - 4"5' - 0"NOTE: (L) DENOTES LOCKED DRAWER LOCATION3' - 0"4"MARBLE SLAB BALANCE TABLE2"3' - 0"3' - 0"2"4' - 0"2' - 11"2' - 7"7' - 0 5/8"LOCKABLE STORAGE CABINETS W/ FRAMED SLIDING GLASS DOORS AND (5) SHELVESPAINTED STEEL CABINETS & DRAWERSEPOXY COUNTERTOP, BACK AND SIDE SPLASH AT PARTITION12"D REAGENT SHELVING ON WALL RAIL ASSEMBLY6' - 4"GAS CYLINDER BRACKETS. PROVIDE WOOD BLOCKING.1' - 3"2' - 0"(L)3A-501SIM3' - 0"3' - 0"SCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELS, TYP.PAINTED STEEL CABINETS W/ SLIDING GLASS DOORSSCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELSEPOXY COUNTERTOP, BACK AND SIDE SPLASH AT PARTITION, TYPPAINTED STEEL CABINETS & DRAWERS3' - 0"2' - 6"2' - 0"2' - 6"2' - 0"2' - 6"3' - 0"1"1"17' - 8"1"3' - 6"3' - 6"3' - 6"3' - 6"3' - 6"3' - 0"4"2' - 7"7' - 0"CANGCANG5A-501SIM.6A-501SIM.2' - 10"EPOXY COUNTERTOP, EPOXY TRANSITION TO STANDING HEIGHT COUNTERTOP18" X 24" PEGBOARD W/ SST DRIP TROUGH12"D OUTER LIP W/ 12"D INNER REAGENT SHELVING ON PAINTED STL UPRIGHTSSCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELS3' - 0"PAINTED STEEL APRONSTEEL CLOSURE PANEL AT KNEE SPACEPAINTED STEEL END PANELS3/4"4' - 8 1/2"3/4"5' - 0"17A-50114A-501SIM3' - 0"2' - 10"3' - 6"3' - 6"3' - 6"STEEL CLOSURE PANEL AT KNEESPACE12"D OUTER LIP W/ 12"D INNER REAGENT SHELVING ON PAINTED STL UPRIGHTSSCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELSPAINTED STEEL CABINETS & DRAWERS2' - 1"10' - 9"2' - 2"3' - 0"2' - 0"2' - 6"3' - 0"1"CA NGPAINTED STEEL END PANELEPOXY COUNTERTOP, BACK AND SIDE SPLASH AT PARTITION15A-50116A-5017' - 5"E-PUREDIE-PURECAPTURE HOOD, SEE MECHANICAL DRAWINGSWOOD SINK BASE CABINETSEPOXY COUNTERTOP BACK AND SIDE SPLASH AT PARTITION, TYP4"3' - 0"SCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELS2' - 0"2' - 6"11A-501SIMRELOCATED FROM E304EXIST WD CABINETSSCHEDULED BASE AT ALL EXPOSED FINISH WALLS AND EXPOSED CABINET BASE FRONTS AND SIDE PANELSEPOXY COUNTERTOP, BACK AND SIDE SPLASH AT PARTITION, TYPWOOD CABINETS & DRAWERS4"3' - 0"1' - 0 3/8"2' - 6"3' - 0"3 3/4"18" X 24" PEGBOARD W/ PLASTIC DRIP TROUGH7' - 0"9' - 3"10A-50111A-501PAINTED STEEL FILLER PANELThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions3/15/2021 3:42:40 PMBIM 360://20636.00 Cornell Corson Hall E303-E347/Cornell Corson Hall E303 E304 E305 E347 Lab and Office Renovation.rvt20636.00CWJInterior Elevations -E318-E334CWJCREA-421100% ConstructionDocumentsCornell UniversityCorson Hall Third FloorLaboratory & Office RenovationIthaca, NYMarch 5, 20211/4" = 1'-0"1Interior Elevation - E318 - North1/4" = 1'-0"2Interior Elevation - E318 - West1/4" = 1'-0"3Interior Elevation - E334 - North A (Accessible Station)1/4" = 1'-0"4Interior Elevation - E334 - East1/4" = 1'-0"5Interior Elevation - E334 - South B1/4" = 1'-0"6Interior Elevation - E334 - West1/4" = 1'-0"7Interior Elevation - E334 - South A1/4" = 1'-0"9Interior Elevation - E334A - North1/4" = 1'-0"8Interior Elevation - E334A - West STEEL BASE CABINET PER ELEVATIONSEPOXY RESIN COUNTER W/ BACKSPLASHFINISHED FLOORDUAL-CHANNEL WIREMOLD, REFER TO ELECTRICAL DRAWINGSWIRE PULLOPEN UTILITY CHASEPROVIDE BLOCKING PER 2/A-000, TYPICALSTEEL WALL CABINET, REFER TO ELEVATIONS2' - 7"7' - 0"4"2' - 6"REFER TO ELEVATIONS2' - 6" TO 3'-0"3' - 6"1' - 1"1" TYP.7 3/8"EPOXY RESIN COUNTER W/ BACKSPLASHFINISHED FLOORDUAL-CHANNEL WIREMOLD, REFER TO ELECTRICAL DRAWINGSOPEN UTILITY CHASEPROVIDE BLOCKING PER 2/A-000, TYPICALSTEEL WALL CABINET, REFER TO ELEVATIONS2' - 7"7' - 0"4"2' - 6"WIRE PULLBASE CABINET BEYONDREMOVABLE METAL PANEL -TYPICAL AT KNEE SPACESMETAL APRON W/ DRAWERREFER TO ELEVATIONS2' - 6" TO 3' - 0"3' - 6"1' - 1"7 3/8"STEEL BASE CABINET PER ELEVATIONSEPOXY RESIN COUNTER W/ BACKSPLASHFINISHED FLOORDUAL-CHANNEL WIREMOLD, REFER TO ELECTRICAL DRAWINGSWIRE PULLOPEN UTILITY CHASEREFER TO ELEVATIONS2' - 6" TO 3' - 0"4"2' - 6"PROVIDE BLOCKING PER 2/A-000, TYPICALADJUSTABLE REAGENT SHELVES W/ LIPS7' - 1"3' - 6"3' - 0"1' - 0"7 3/8"REFER TO ELEVATIONS FOR INVERTED TOP SHELF LOCATIONSEPOXY RESIN COUNTER W/ BACKSPLASHDUAL-CHANNEL WIREMOLD, REFER TO ELECTRICAL DRAWINGSREFER TO ELEVATIONS2' - 6" TO 3' - 0"4"2' - 6"PROVIDE BLOCKING PER 2/A-000, TYPICALADJUSTABLE REAGENT SHELVES W/ LIPS7' - 1"3' - 6"3' - 0"1' - 0"FINISHED FLOOROPEN UTILITY CHASEWIRE PULLBASE CABINET BEYONDREMOVABLE METAL PANEL -TYPICAL AT KNEE SPACESMETAL APRON W/ DRAWER7 3/8"REFER TO ELEVATIONS FOR INVERTED TOP SHELF LOCATIONSSTEEL BASE CABINET PER ELEVATIONSEPOXY RESIN COUNTER W/ BACKSPLASHFINISHED FLOORDUAL-CHANNEL WIREMOLD, REFER TO ELECTRICAL DRAWINGSWIRE PULLPROVIDE BLOCKING PER 2/A-000, TYPICALSTEEL WALL CABINET, REFER TO ELEVATIONS2' - 7"7' - 0"4"2' - 1"REFER TO ELEVATIONS2' - 6" TO 3'-0"3' - 6"1' - 1"EPOXY RESIN COUNTER W/ BACKSPLASHFINISHED FLOORDUAL-CHANNEL WIREMOLD, REFER TO ELECTRICAL DRAWINGSPROVIDE BLOCKING PER 2/A-000, TYPICALSTEEL WALL CABINET, REFER TO ELEVATIONS2' - 7"7' - 0"4"2' - 1"WIRE PULLBASE CABINET BEYONDMETAL APRON W/ DRAWERREFER TO ELEVATIONS2' - 6" TO 3' - 0"3' - 6"1' - 1"STEEL BASE CABINET PER ELEVATIONSEPOXY RESIN COUNTER W/ BACKSPLASHFINISHED FLOORDUAL-CHANNEL WIREMOLD, REFER TO ELECTRICAL DRAWINGSWIRE PULLREFER TO ELEVATIONS2' - 6" TO 3' - 0"4"2' - 1"PROVIDE BLOCKING PER 2/A-000, TYPICALADJUSTABLE REAGENT SHELVES W/ LIPS7' - 1"3' - 6"3' - 0"1' - 0"REFER TO ELEVATIONS FOR INVERTED TOP SHELF LOCATIONSEPOXY RESIN COUNTER W/ BACKSPLASHDUAL-CHANNEL WIREMOLD, REFER TO ELECTRICAL DRAWINGSREFER TO ELEVATIONS2' - 6" TO 3' - 0"4"2' - 1"PROVIDE BLOCKING PER 2/A-000, TYPICALADJUSTABLE REAGENT SHELVES W/ LIPS7' - 1"3' - 6"3' - 0"1' - 0"FINISHED FLOORWIRE PULLBASE CABINET BEYONDMETAL APRON W/ DRAWERREFER TO ELEVATIONS FOR INVERTED TOP SHELF LOCATIONS2' - 0"3' - 0"1' - 0"1' - 0"3' - 0"4' - 1"1' - 9 5/8"1' - 2 3/4"ISLAND UPRIGHTINVERTEDREAGENT SHELF BEYONDINNER & OUTERREAGENT SHELFW/ LIP BEYONDEPOXY RESIN COUNTER WITH BACKSPLASHOPEN UTILITYCHASEFINISHED FLOOR3' - 6"PEG BOARD W/ SST DRIP TROUGHSTEEL BASE CABINET PER ELEVATIONSEPOXY RESIN COUNTERFALSE FRONT5' - 0"7' - 1"REMOVABLE METAL PANEL -TYPICAL AT KNEE SPACES1"A-50117STEEL BASE CABINET PER ELEVATIONSEPOXY RESIN COUNTER W/ BACKSPLASHFINISHED FLOORDUAL-CHANNEL WIREMOLD, REFER TO ELECTRICAL DRAWINGSWIRE PULL3' - 0"4"1' - 7"PROVIDE BLOCKING PER 2/A-000, TYPICALADJUSTABLE REAGENT SHELVES W/ LIPS7' - 1"3' - 6"3' - 0"1' - 0"1' - 6"WOOD BASE CABINET PER ELEVATIONSEPOXY RESIN COUNTER W/ BACKSPLASHFINISHED FLOORDUAL-CHANNEL WIREMOLD, REFER TO ELECTRICAL DRAWINGSWIRE PULLOPEN UTILITY CHASEEXIST WOOD WALL CABINETS RELOCATED FROM ROOM 3047' - 0"4"2' - 6"3' - 0"3' - 6"VIF2' - 7"VIF1' - 1"7 3/8"WOOD BASE CABINET PER ELEVATIONSEPOXY RESIN COUNTER W/ BACKSPLASHFINISHED FLOORWIRE PULL4"2' - 6"3' - 0"FALSE FRONTEPOXY PAINTED STEELFIXED SINK SUPPORTSHELF5"PEG BOARD W/ SST DRIP TROUGH3' - 6"STEEL BASE CABINET PER ELEVATIONSEPOXY RESIN COUNTER W/ BACKSPLASHFINISHED FLOORDUAL-CHANNEL WIREMOLD, REFER TO ELECTRICAL DRAWINGSFALSE FRONTPROVIDE BLOCKING PER 2/A-000, TYPICALSTEEL WALL CABINET, REFER TO ELEVATIONS2' - 7"7' - 0"4"2' - 1"3' - 0"3' - 6"6"1' - 6"OPEN UTILITY CHASE1' - 1"STEEL BASE CABINET PER ELEVATIONSEPOXY RESIN COUNTER W/ BACKSPLASHFINISHED FLOORWIRE PULLADJUSTABLE REAGENT SHELVES W/ LIPS7' - 1"4' - 1"3' - 0"1' - 9 5/8"1' - 2 3/4"1' - 0"1' - 0"ISLAND UPRIGHTINNER & OUTERREAGENT SHELFW/ LIP BEYOND3' - 0"5' - 0"1"OPEN UTILITY CHASEEPOXY RESIN COUNTER W/ BACKSPLASHFINISHED FLOORWIRE PULLBASE CABINET BEYONDMETAL APRON W/ DRAWER3' - 0"1' - 0"1' - 0"4' - 1"3' - 0"7' - 1"ADJUSTABLE REAGENT SHELVES W/ LIPSISLAND UPRIGHTINNER & OUTERREAGENT SHELFW/ LIP BEYONDREMOVABLE METAL PANEL -TYPICAL AT KNEE SPACES5' - 0"1' - 9 5/8"1' - 2 3/4"1' - 9 5/8"1"1"OPEN UTILITY CHASESTEEL BASE CABINET PER ELEVATIONSEPOXY RESIN COUNTER W/ BACKSPLASHFINISHED FLOORWIRE PULLFALSE FRONT2' - 1"4"2' - 6" TO 3' - 0"3' - 6"7 3/8"PEG BOARD W/ SST DRIP TROUGHSTANDING OR ADA HEIGHTADA HEIGHT OR SITTING HEIGHTALIGN FRONT OF SIDESPLASH FLUSH WITH FRONT OF ADJACENT WORKSURFACES WHEN TRANSITIONING HEIGHTSThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions3/15/2021 3:42:41 PMBIM 360://20636.00 Cornell Corson Hall E303-E347/Cornell Corson Hall E303 E304 E305 E347 Lab and Office Renovation.rvt20636.00CWJInterior Details, LabCaseworkCWJCREA-501100% ConstructionDocumentsCornell UniversityCorson Hall Third FloorLaboratory & Office RenovationIthaca, NYMarch 5, 20213/4" = 1'-0"1Section at Casework - A3/4" = 1'-0"2Section at Casework - B3/4" = 1'-0"3Section at Casework - C3/4" = 1'-0"4Section at Casework - D3/4" = 1'-0"5Section at Casework - E3/4" = 1'-0"6Section at Casework - F3/4" = 1'-0"7Section at Casework - G3/4" = 1'-0"8Section at Casework - H3/4" = 1'-0"14Section at Bench, Sinks3/4" = 1'-0"9Section at Casework - I3/4" = 1'-0"10Section at Casework - J3/4" = 1'-0"11Section at Casework - K3/4" = 1'-0"12Section at Casework - L3/4" = 1'-0"15Section at Bench, Typ.3/4" = 1'-0"16Section at Bench, Knee Spaces3/4" = 1'-0"13Section at Casework - O1 1/2" = 1'-0"17Worksurface Transition Detail DOOR ELEVATIONSFRAME ELEVATIONSGLAZING TYPES:S-11/4" SAFETY GLASSS-21/4" FIRE-RATED SAFETY GLASSD1F1SCHEDSEE DOORSEE DOOR SCHEDULED2SCHEDSEE DOORMAX3' - 7"8"5"8"SEE DOOR SCHEDULESCHEDSEE DOORSEE DOOR SCHED FOR GLAZING TYPE, TYP.SEE DOOR SCHED FOR GLAZING TYPE, TYP.SEE DOOR SCHEDULEDOUBLE MTL STUD AT JAMBS, TYPICALDOORHM WRAPPED FRAME W/ GYP BD RETURNS AND MTL STUD ANCHORS2"PLANSEE FLRPARTITION TYPE AS SCHED.J1TYP.5/8"MIN.1/2"4"WALL WHERE APPLICABLE5/8" TYP3 5/8" METAL STUDS AT DOOR POCKETPOCKET DOOR3/4" WOOD TRIMJ22"2 5/8"4"PARTITIONTYPE ASSCHEDULEDDOUBLE METALSTUD AT JAMBS, TYPWOOD BLKG.PRE-HUNGWOOD FRAMEWD. JAMB & STOPDOOR3/4" X 3" WOOD CASINGJ3WALL WHERE APPLICABLE4"3/4" X 3" WOOD CASINGPLANSEE FLRWOOD BLOCKINGPOCKET DOOR2"2 5/8"HEAD DETAILWOOD BLOCKING2 X WOOD HEADER3/4" WOOD TRIMADJUSTABLE SLIDING DOOR TRACK ASSEMBLYCLEAR36" MINPLANSEE FLOORWOOD BLOCKINGBUMPER INSTALLED AT 42" AFFTYP.60" TO TOP OF SIGNSINGLE DOOR9" AT PULL SIDE4" AT PUSH SIDELOCATE ON LATCH SIDE OF DOOR3 1/2"3 1/2"E0003/8"1/2"3/4"3/4'' LETTERING (WHITE)CENTER ON SIGNBRAILLECOLOR: AS SELECTED FROM MFR FULL LINEEQEQEQEQ5' - 2"5/4 X 6 HARDWOOD, FINISH AS SELECTED BY ARCHITECT(2) STAINLESS STEEL BOBRICK B-6827 HOOKSSectionElevation1' - 4"EQEQEQEQWD BLOCKING BETWEEN STUDS9"5' - 2"5/4 X 6 HARDWOOD, FINISH AS SELECTED BY ARCHITECT(2) STAINLESS STEEL BOBRICK B-6827 HOOKSSectionElevation2' - 2"EQEQEQEQWD BLOCKING BETWEEN STUDS9"9"REMARKS1. 3/4" MAX. UNDERCUT2. POCKET DOOR1/8" ALUMINUM PLATE, BOD: PEMKO ALUMINUM PLATE 18/1EXISTING RESILIENT SHEET1/8"END OF ALUMINUM PLATE TO COVER EDGE OF RESILIENT SHEETSHEET VINYL TO TRANSITION BENEATH DOOR PANELDOOR FRAME BEYONDDOOR PANEL 6 1/8" VIFMARBLE THRESHOLDRESINOUS FLOOR1/4"SHEET VINYLDOOR FRAME BEYONDDOOR PANEL 1/8"WIDTH OF SCHEDULE FRAMEDIVIDER STRIPDIVIDER STRIP2"These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions3/15/2021 3:42:42 PMBIM 360://20636.00 Cornell Corson Hall E303-E347/Cornell Corson Hall E303 E304 E305 E347 Lab and Office Renovation.rvt20636.00CWJInterior Details & DoorScheduleCWJCREA-601100% ConstructionDocumentsCornell UniversityCorson Hall Third FloorLaboratory & Office RenovationIthaca, NYMarch 5, 2021DOOR SCHEDULEDOOR #DOORFRAMEHARDWARE LABEL THRESHOLD REMARKS DOOR #LEAFSSIZETYPE MATERIAL FINISH GLASS ELEVATION JAMB MATERIAL FINISHWIDTH HEIGHT THICKLEVEL 3E304A (1)3' - 0" 7' - 0" 1 3/4" D1WD PT-2S-1F1J3WDPT-2 REFERENCEHARDWARESCHEDULE- EXIST MARBLEE304AE304B (1)3' - 4" 7' - 0" 1 3/4" D1WD PT-2-F1J2HMPT-2 REFERENCEHARDWARESCHEDULE-- 2E304BE318(1)3' - 0" 7' - 0" 1 3/4" D2WD PT-2/PT-3S-2F1J1HM PT-2/PT-3 REFERENCEHARDWARESCHEDULE45 MIN Y, 1/8" ALUMINUMPLATE, DETAIL3/A-6011E318E318A (1)3' - 0" 7' - 0" 1 3/4" D2WD PT-2S-1F1J1HMPT-2 REFERENCEHARDWARESCHEDULE--E318AE334A (1)3' - 0" 7' - 0" 1 3/4" D2WD PT-2S-1F1J3WDPT-2 REFERENCEHARDWARESCHEDULE-Y, MARBLE,DETAIL 4/A-6011E334AE334B (1)3' - 0" 7' - 0" 1 3/4" D2WD PT-2S-1F1J1HMPT-2 REFERENCEHARDWARESCHEDULE--E334BJAMB DETAILSSIGNAGE MOUNTING TYPESTYPICAL ROOM SIGNAGE TYPE3/4" = 1'-0"2Coat Rack Detail - OfficeNOTE: DOORS E303, E304, E305, E321, E323 AND E334 ARE EXISTING TO REMAIN.3/4" = 1'-0"1Coat Rack Detail - Lab6" = 1'-0"3Threshold - Burnished Aluminum6" = 1'-0"4Threshold - Marble MISCELLANEOUS FINISH REQUIREMENTS TO WALLS, FLOORS & CEILINGS IN AREAS AFFECTED BY DEMO HAVE NOT BEEN TOTALLY INCORPORATED INTO THE ROOM FINISH SCHEDULE. REFER TO DEMOLITION, FLOOR & REFLECTED CEILING PLANS FOR EXTENT OF "CUTTING & PATCHING". PATCHING SHALL BE THE REPAIR WORK REQUIRED TO RESTORE SURFACES TO THE ORIGINAL CONDITION AND/OR MATCHING THE ADJACENT SURFACES.FLOORING TO RUN BENEATH ANY OPEN SPACES IN ROOMS, INCLUDING ADA CABINETS & APPLIANCES IN THE ROOM FINISH SCHEDULE -IN ANY ROW OR COLUMN "-" or "ETR" INDICATES THERE ARE NO CHANGES OR NEW FINISHES, EXISTING TO REMAINPAINT ALL EXPOSED HVAC, PLUMBING & ELECTRICAL CONSTRUCTION TO MATCH ADJACENT OR BACKGROUND SURFACES UNLESS OTHERWISE NOTED, INCLUDING BUT NOT LIMITED TO STEEL ACCESS DOORS & FRAME, STEEL GRILLES, DIFFUSERS, REGISTERS, AND LOUVERS. DO NOT PAINT OPERATIONAL COMPONENTS OF SYSTEMS INCLUDING BUT NOT LIMITED TO SPRINKLER HEADS, FIRE, SMOKE, OR HEAT DETECTORS.PROVIDE TRANSITION STRIPS BETWEEN DIFFERENT FLOOR MATERIALS AS INDICATED ON SCHEDULE.WHERE TRANSITIONS OCCUR AT DOORWAYS, CENTER TRANSITION BENEATH DOOR.PAINT DOOR FRAMES & DOORS UNLESS OTHERWISE INDICATED. FINISH FRAMES & DOORS THE SAME ON BOTH SIDES UNLESS INDICATED AS A SPLIT FINISH IN THE DOOR SCHEDULE.ALL GYPSUM BOARD CEILINGS TO BE FLAT FINISH UNLESS OTHERWISE NOTEDALL PAINTED VERTICAL SURFACES (WALLS, SOFFITS, COLUMNS, ETC ) TO BE AN EGGSHELL FINISH UNLESS OTHERWISE NOTED.GENERAL NOTES -FINISHESA.B.C.D.E.F.G.H.I.J.NOTE: PLANK SIZE NOT TO SCALE, FOR DIRECTION ONLY.FULL LVT TILE, EDGE TO BE CENTERED UNDER DOOR LVT-1EXIST.RESILIENTSHEETTS-1PLANKORIENTATIONFACULTY OFFICEE303LABE305LABE304DARK ROOME304BSV-1EXIST.RESILIENTSHEETEXISTRESILIENTSHEETSV-1EXIST MARBLE THRESHOLD TO REMAINFINISH LEGENDSECTION 07 92 00 -JOINT SEALANTJOINT SEALANTAT COUNTERTOP TO WALL TRANSITIONS, MATCH JOINT SEALANT TO COUNTERTOPSECTION 09 51 13 -ACOUSTICAL PANEL CEILINGSACOUSTICAL CEILING TILE (ACT)ACT-1CERTAINTEED PERFORM TILE, SQUARE LAY IN MINERAL FIBER TILE, STYLE: FINE FISSURED, TYPE: HHF-197, SIZE: 24" X 24", COLOR: WHITE, INCLUDE COORDINATING 15/16" SUSPENSION GRID, COLOR: WHITESECTION 09 65 00 -RESILIENT FLOORINGLUXURY VINYL FLOORING (LVT)LVT-1MANNINGTON, LUXURY VINYL TILE WITH MICRO BEVEL EDGES, COLLECTION: SELECT PLANK, SIZE: 5" x 48", COLOR: AS SELECTED FROM MANUFACTURER'S FULL LINE, INSTALLATION: 1/3STAGGERED RUNNING BOND, DIRECTION AS INDICATED ON PLANS (OFFICE E303)LVT-2MANNINGTON, LUXURY VINYL TILE WITH MICRO BEVEL EDGES, COLLECTION: SELECT PLANK, SIZE: 5" x 48", COLOR: AS SELECTED FROM MANUFACTURER'S FULL LINE, INSTALLATION: 1/3STAGGERED RUNNING BOND, DIRECTION AS INDICATED ON PLANS (OFFICE E321)SHEET VINYL (SV)SV-1MANNINGTON, BIOSPEC MD, THICKNESS: .080", COLOR: OYSTER WHITE 15201 (LABS)TRANSITION STRIP (TS)TS-1TARKETT, WHEELED TRAFFIC TRANSITION, CTA-XX-JL, COLOR: AS SELECTED FROM MANUFACTURER'S FULL LINE (LVT TO EXISTING RESILIENT SHEET)TS-2TARKETT, WHEELED TRAFFIC TRANSITION, CTA-XX-JL, COLOR: AS SELECTED FROM MANUFACTURER'S FULL LINE (LVT TO EXISTING RESILIENT SHEET)SECTION 09 65 13 -RESILIENT BASE AND ACCESSORIESRUBBER BASE (RB)RB-1JOHNSONITE, RUBBER BASE, 4" H, COVE TOE BASE, COLOR: AS SELECTED FROM MANUFACTURER'S FULL LINERB-2JOHNSONITE, RUBBER BASE, 4" H, COVE TOE BASE, COLOR: AS SELECTED FROM MANUFACTURER'S FULL LINERB-3JOHNSONITE, RUBBER BASE, 4" H, COVE TOE BASE, COLOR: AS SELECTED FROM MANUFACTURER'S FULL LINESECTION 09 67 23 -RESINOUS FLOORINGRES-1 EPOXY RESINOUS FLOORING SYSTEM: SHERWIN WILLIAMS, TRAFFICOTE 105 W/ GP3741 NOVOLAC EPOXY ACID RESISTANT TOP COAT, COLOR: AS SELECTED FROM MANUFACTURER'S FULL LINE (ACID WASH E334A)SECTION 09 91 23 -INTERIOR PAINTINGPAINT (PT)-ALL DOORS, FRAMES AND TRIM –SEMI-GLOSS-CEILINGS –FLAT-ALL PAINTED VERTICAL SURFACES (WALLS, SOFFITS, COLUMNS, ETC) TO BE AN EGGSHELL FINISH.-AT EXPOSED CEILING USE DRYFALL PAINT.PT-1BENJAMIN MOORE, COLOR: LINEN WHITE 912, FINISH: INTERIOR SATIN (GENERAL)PT-2BENJAMIN MOORE, COLOR: LINEN WHITE, FINISH: SEMI-GLOSS (DOOR &FRAMES, WHERE INDICATED TO BE SPLIT FINISH USE AT DOORS AND FRAME ROOM SIDE)PT-3BENJAMIN MOORE, COLOR: MATCH EXISTING, FINISH: SEMI-GLOSS (DOOR & FRAMES, CORRIDOR SIDE)SECTION 10 14 00 -SIGNSPANEL SIGNAGEINTEGRAL ACRYLIC SHEET COLOR:AS SELECTED FROM MANUFACTURER'S FULL LINE RAISED TEXT AND TYPEFACE COLOR:AS SELECTED FROM MANUFACTURER'S FULL LINESECTION 12 24 13 –ROLLER WINDOW SHADESWINDOW TREATMENTS (WT)WT-1DRAPER INC. -STYLE: 3G MERMET COMPANY M-SCREEN #8503 -FLEX SHADE MESH SHADE WITH FASCIA, MANUALLY CLUTCH CONTROLLED, 3% OPENNESS, SHADE COLOR: 002020 WHITE/LINEN, HARDWARE COLOR: IVORY (EXTERIOR WINDOWS)SECTION 12 35 51 -LABORATORY CASEWORKMETAL CASEWORKMOTT MANUFACTURING, SCIENCE LABORATORY FURNITURE, COLOR: WHITE.WOOD CASEWORKMOTT MANUFACTURING, SCIENCE LABORATORY FURNITURE, COLOR: AS SELECTED FROM MANUFACTURER'S FULL LINE.SECTION 12 36 53 -LABORATORY WORK SURFACESEPOXY COUNTERTOP (EC)EC-1 DURCON, EPOXY RESIN WORKS, COLOR: BLACK1. WT-1 AT EXTERIOR WINDOWS2.PAINT EXISTING CORRIDOR DOOR AND FRAME PT-2 AND PT-3 AS INDICATED ON THE FINISH LEGENDROOM FINISH SCHEDULE REMARKSFULL LVT TILE, EDGE TO BE CENTERED UNDER DOOR LVT-2EXIST.RESILIENTSHEETTS-2PLANKORIENTATIONOFFICEE321COMPUTATIONAL LABE323NOTE: PLANK SIZE NOT TO SCALE, FOR DIRECTION ONLY.SOIL ROOME318VESTE334BOPEN LABE334ACID WASHE334AEXISTRESILIENTSHEETSV-2EXISTRESILIENTSHEETSV-2THRESHOLDMARBLE THRESHOLDSV-2RES-1RES-1 TO CONTINUE UNDERNEATH CASEWORK LOCATIONSThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions3/15/2021 3:42:44 PMBIM 360://20636.00 Cornell Corson Hall E303-E347/Cornell Corson Hall E303 E304 E305 E347 Lab and Office Renovation.rvt20636.00CWJFinish Plans &ScheduleCWJCREA-602100% ConstructionDocumentsCornell UniversityCorson Hall Third FloorLaboratory & Office RenovationIthaca, NYMarch 5, 2021ROOM FINISH SCHEDULEROOMNUMBERROOM NAMEFLOORBASEWALLCEILINGFINISHREMARKSROOMNUMBERMATERIAL/ FINISH MATERIAL/ FINISHNORTHSOUTHEASTWESTMATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISHLEVEL 3E303 FACULTY OFFICELVT-1RB-1ETR-CMU PT-1 ETR-GWB PT-1 ETR-GWB PT-1 ETR-GWB PT-1 ACT-1 1, 2E303E304 LABSV-1RB-2ETR-GWB PT-1 ETR-GWB PT-1 ETR-GWB PT-1 ETR-GWB PT-1 ACT-1 2E304E304B DARK ROOMSV-1RB-2ETR-GWB PT-1 ETR-GWB PT-1 ETR-GWB PT-1 ETR-GWB PT-1 ACT-1E304BE305 LABSV-1RB-2ETR-CMU PT-1 ETR-GWB PT-1 ETR-GWB PT-1 ETR-GWB PT-1 ACT-1 1, 2E305E318 SOIL ROOMSV-1RB-2GWBPT-1 GWB PT-1 GWB PT-1 ETR-GWB PT-1 ACT-1 2E318E321 OFFICELVT-2RB-3ETR-GWB PT-1 ETR-GWB PT-1 ETR-CMU PT-1 ETR-GWB PT-1 ETR-ACT 1, 2E321E323 COMPUTATIONAL LABLVT-2RB-3ETR-GWB PT-1 ETR-GWB PT-1 ETR-CMU PT-1 ETR-GWB PT-1 ETR-ACT 1, 2E323E334 OPEN LABSV-1RB-2 GWB/ETR-GWB PT-1 GWB PT-1 GWB PT-1 GWB/ETR-GWB PT-1 ACT-1 2E334E334A ACID WASHRES-1RES-1GWBPT-1 GWB PT-1 GWB PT-1 ETR-GWB PT-1 GWB, PT-1E334AE334B VESTSV-1RB-2GWBPT-1 GWB PT-1 GWB PT-1 GWBPT-1 ACT-1E334B1/4" = 1'-0"1Partial Third Floor Finish Plan - E303-E3051/4" = 1'-0"3Partial Third Floor Finish Plan - E318-E334N WORKSURFACEWORKSURFACESEE ELEVATIONSREMOVABLE ACCESS PANELSECTIONAIRFOIL2' - 6" +/- OVERALL+/- 1' - 1 1/4"LIGHT ENCLOSUREFRONT ELEVATIONRECEPTACLECOMBO SWITCH5' - 0"WATER3" x 6" CUPSINK SAFETY MONITOR/ ALARM5' - 0"2' - 6"5/8"5"5"2 1/4"3 3/4"2 1/2" DIA HOLE, TYP 2 PLACES1' - 4"2 7/16"1 1/2" DIA HOLE, TYP 2 PLACESR0.56 +/-0.12 AT TOP SURFACE, TYP 4 CORNERSCUP SINK, COORDINATE DIMENSION TO AVOID FRAME BELOW+/- 7"+/- 1' - 1 1/4"3/8" TYPPLAN COMPRESSED AIRThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions3/15/2021 3:42:44 PMBIM 360://20636.00 Cornell Corson Hall E303-E347/Cornell Corson Hall E303 E304 E305 E347 Lab and Office Renovation.rvt20636.00CWJLab Equipment andFume Hood ScheduleCWJCREA-603100% ConstructionDocumentsCornell UniversityCorson Hall Third FloorLaboratory & Office RenovationIthaca, NYMarch 5, 2021LAB EQUIPMENT SCHEDULE - E303-E305LETTER QTY EQUIPMENT NAME MANUFACTURER MODEL NO. LOCATIONDIMENSIONSELECTRICALHOUSE LABORATORY PLUMBING SYSTEMSCYLINDERGASESOPERATING ENVIRONMENTHEATGENERATION(BTUH)EXHAUST(CFM)OWNERFURNISHEDOWNERINSTALLEDCONTRACTORFURNISHEDCONTRACTORINSTALLEDCOMMENTSHEIGHT(IN)WIDTH(IN)DEPTH(IN)WEIGHT(LBS)NORMALVOLTAGE (VAC)PHASE Hz AMPS HP kVA WATTS GROUNDEMERGENCYPOWERPLUGTYPEDCW DHW PCWLABDRAINLABVENTRO/DIGASPROPANEVACCA85PSICALPTEMP(*F)HUMIDITY %VIBRATIONSENSITIVEA 1 STEREOMICROSCOPE LEICAS7EBENCH 18 1/4 8 5/8 10 7/8 25 12060- - - - - - - - - - -XXB 1 STEREOMICROSCOPE LEICAM165 CBENCH 21 1/2 13 3/8 17 1/412060- - - - - - - - - - -XXC 1 FREEZERFISHER SCIENTIFIC 20LFEEVWAFLOOR 73 1/8 34 32 1/8 200 12060 5.3Y NEMA5-15P- - - - - - - - - - -YXXD 1 REFRIGERATOR FISHER SCIENTIFIC 20LREEVWAFLOOR 73 1/8 34 32 1/8 283 12060Y NEMA5-15P- - - - - - - - - - -YXXE 1 MUFFLE FURNACE THERMO FISHER F6018BENCH 21 19 1/8 20 1/8 134 20860 11.22325- - - - - - - - - - -XXHEATS 100*C to 1200*CF 1 DRYING OVEN THERMO FISHER 51028115BENCH 28 1/4 20 7/8 22 1/4 124 12060 14.41730NEMA6-20- - - - - - - - - - -XXG 1 DOC-TN ANALYZER SHIMADZUTOC-LBENCH 18 7/8 13 3/8 26 77.2 12060. 0.6Y, < 100OHMSAC100-120V- - - - - - - -ULTRA-PUREAIR50-95YXXDRAIN TANK LOCATED BELOW COUNTERH 1 GASCHROMATOGRAPHSHIMADZUGC-2014BENCH 27 15 24 110 12060Y, < 100OHMS5-20R - - - - - - -HE, P5, H2 &ZERO-GRADEAIR64-82 40-70 Y4760XXOWN DEDICATED 20-AMP CIRCUIT,CHROMATOGRAPHIC GRADE SS TUBING FORGAS LINES, "ZERO AIR" NOTED AS "ULTRA-PUREAIR" ON PLANSJ 1 MARBLE SLABBALANCE TABLEFLOOR 31 35 24 725-- - - - - - --- - - - - - - - - - - ----XXK 1 DOC-TN ANALYZER SHIMADZUASI-LBENCH 19 5/8 14 5/8 21 1/4 30.9 SEE "G"--XXL 1 DOC-TN ANALYZER SHIMADZUTNM-LON "G" 5 7/87/813 3/8 26 13.2 SEE "G"-ULTRA-PUREAIRXXM 1 GASCHROMATOGRAPHSHIMADZUAOC-6000ON "H" 26 60 20 33 120605-15R-XXCAN SHARE A 15-AMP CIRCUIT W/ COMPUTERN 1 GROWTH CHAMBER PERCIVALI-36VLFLOOR 77.2 33.5 33.61201 60 12 1/4YY NEMA5-15P- - - - - - - - - - --XXLABORATORY FUME HOOD SCHEDULEKEYNOTE PURPOSE MODEL EXHAUST TYPE DEPTH WIDTH SASH CONFIGURATION LINER MATERIAL CUPSINK SERVICE 1 SERVICE 2SERVICE 3FURRING PANEL ADDITIONAL REQUIREMENTSH-1 ADA MOTT 7341050 VAV 32.7" 5'-0" COMBINATIONFRPY CWCA DUPLEX RECEPTACLE (EACH SIDE)- VAC PROVIDED BY VAC PUMPH-2 ADA MOTT 7341050 VAV 32.7" 5'-0" COMBINATIONFRPY CWCA DUPLEX RECEPTACLE (EACH SIDE)- VAC PROVIDED BY VAC PUMP3/4" = 1'-0"1Accessible Fume Hood DetailsNOTE: SEE MECHANICAL DRAWINGS FOR CONTROLS, INCLUDING AIRFLOW MONITOR AND SASH POSITION INDICATOR(S)SHOWN AS:SHOWN AS:LAB EQUIPMENT SCHEDULE - E318-E334LETTER QTY EQUIPMENT NAME MANUFACTURER MODEL NO. LOCATIONDIMENSIONSELECTRICALHOUSE LABORATORY PLUMBING SYSTEMSCYLINDERGASESOPERATING ENVIRONMENTHEATGENERATION(BTUH)EXHAUST(CFM)OWNERFURNISHEDOWNERINSTALLEDCONTRACTORFURNISHEDCONTRACTORINSTALLEDCOMMENTSHEIGHT(IN)WIDTH(IN)DEPTH(IN)WEIGHT(LBS)NORMALVOLTAGE (VAC)PHASE Hz AMPS HP kVA WATTS GROUNDEMERGENCYPOWERPLUG TYPE DCW DHW PCWLABDRAINLABVENTRO/DIGASPROPANEVACCA85PSICALPTEMP(*F)HUMIDITY %VIBRATIONSENSITIVEA' 2 BALANCEVWR10204-968BAL.TABLEOPEN LAB14 8 1/5 13 13120603-PRONGGROUNDEDXXB' 1 -20 FREEZERGEFUF21DLRWWFLOOR 76 1/2 32.88 31 3/8 215 12060Y 3-PRONGGROUNDEDXXC' 1 REFRIGERATOR WHIRLPOOLWRR56X18FWFLOOR 67 30.25 29 1/812060Y 3-PRONGGROUNDEDXXD' 1 GASCHROMATOGRAPHSHIMADZUGC-2014BENCH 27.2 16 27 106 120603-PRONGGROUNDEDN2, H2, P5,ZERO AIRXX"ZERO AIR" NOTED AS "ULTRA-PURE AIR"ON PLANSE' 1 CRDS GASCONCENTRATIONANALYZERPICARROG2508BENCH 7 17 17.5 5012060<375ATSTARTUP3-PRONGGROUNDEDCH4, CO2, N2O,ULTRA-PUREAIRXXF' 1 CENTRIFUGE VWRBENCHTOP GENERAL BENCH 13.6 15.55 20.5120603-PRONGGROUNDEDXXG' 1 SHAKERVWR89032-108BENCH 7 28.5 26.5 200 120603-PRONGGROUNDEDXXH' 1 GRINDER/PULVERIZERSPEX8530 SHATTERBOX FLOOR 40 19 19 207 120603-PRONGGROUNDEDXXCAPTURE HOOD TBDJ' 2 DRYING OVEN THERMO FISHER 51028115BENCH 28 1/4 20 7/8 22 1/4 124 12060 14.4 - 1730NEMA 6-20 - - - - - - - - - -----XXCAPTURE HOOD TBDK' 1 GASCHROMATOGRAPHAUTOSAMPLERSHIMADZUHS-20BENCH 17 22 21.5 73120603-PRONGGROUNDEDN2XXSHOWN AS: SECTION 07 92 00 JOINT SEALANTS1. PRODUCT: MILDEW RESISTANT SILICONE SEALANTA. MANUFACTURER: DOW CORNINGB. PRODUCT: 786 MILDEW RESISTANTC. COLOR: TO BE SELECTED FROM MANUFACTURER'S FULL RANGESPECIFICATIONS:SECTION 09 29 00 GYPSUM BOARD1. GYPSUM BOARD, TYPE X: ASTM C1396/C1396M.1. LONG EDGES:TAPERED.2. SOUND-ATTENUATION BLANKETS: ASTM C665, TYPE I (BLANKETS WITHOUT MEMBRANE FACING) PRODUCED BY COMBINING THERMOSETTING RESINS WITHMINERAL FIBERS MANUFACTURED FROM GLASS, SLAG WOOL, OR ROCK WOOL.1. FIRE-RESISTANCE-RATED ASSEMBLIES: COMPLY WITH MINERAL-FIBER REQUIREMENTS OF ASSEMBLY.3. ACOUSTICAL SEALANT: MANUFACTURER'S STANDARD NONSAG, PAINTABLE, NONSTAINING LATEX SEALANT COMPLYING WITH ASTM C834. PRODUCT EFFECTIVELY REDUCES AIRBORNE SOUND TRANSMISSION THROUGH PERIMETER JOINTS AND OPENINGS IN BUILDING CONSTRUCTION AS DEMONSTRATED BY TESTING REPRESENTATIVE ASSEMBLIES ACCORDING TO ASTM E90.4. GYPSUM BOARD FINISH LEVELS: FINISH PANELS TO LEVELS INDICATED BELOW AND ACCORDING TO ASTM C840:1. LEVEL 1: CEILING PLENUM AREAS, CONCEALED AREAS, AND WHERE INDICATED.2. LEVEL 4:AT PANEL SURFACES THAT WILL BE EXPOSED TO VIEW UNLESS OTHERWISE INDICATED.SECTION 09 22 16 NON-STRUCTURAL METAL FRAMING1.STUDS AND RUNNERS: ASTM C 645A. MIN BASE-METAL THICKNESS: 0.027"1. EQUIVALENT COATINGS AND METAL THICKNESS (DIMPLED STEEL) STUDS WILL NOT BE ALLOWED.B. DEPTH: AS INDICATED ON DRAWINGSC. PROTECTIVE COATING: ASTM A 653/A 653M, G40, HOT-DIP GALVANIZEDSECTION 02 70 00 SELECTIVE DEMOLITION1.SUMMARYA. DEMOLISH AND REMOVE SELECTED PORTIONS OF BUILDING.B. DISCONNECT AND CAP OR SEAL UTILITIES PRIOR TO DEMOLITION.C. MAINTAIN AND PROTECT ALL EXISTING UTILITY SERVICES.2. DEMOLITIONA. INSTALL TEMPORARY DUSTPROOF PARTITIONS AND ENCLOSURES.B. PATCH AND REPAIR DAMAGED SURFACES CAUSED BY SELECTIVE DEMOLITION OPERATIONS.C. DEMOLISHED MATERIALS BECOME CONTRACTOR'S PROPERTY, UNLESS OTHERWISE INDICATED.3. DISPOSAL OF DEMOLISHED MATERIALS:A. BURNING: NOT PERMITTED.B. DISPOSAL: OFF OWNER'S PROPERTY.4. SELECTIVE DEMOLITION SCHEDULEA. COORDINATE WITH OWNER'S REPRESENTATIVE FOR UTILITY SHUTDOWNS5. OCCUPANCYA. AREAS ADJACENT TO THE AREAS OF DEMOLITION MAY BE OCCUPIED. WORK IS TO BE CONDUCTED IN SUCH A MANNER AS TO MINIMIZE THE DISRUPTION OF NORMAL OPERATIONS.6. CONDITIONS OF STRUCTURESA. THE OWNER ASSUMES NO RESPONSIBILITY FOR ACTUAL CONDITIONS OF ITEMS OR STRUCTURES TO BE DEMOLISHED. CONDITIONS EXISTING AT THE TIME OF COMMENCEMENT OF CONTRACT WILL BE MAINTAINED BY THE OWNER INSOFAR AS IS PRACTICAL. HOWEVER, VARIATIONS WITHIN THE STRUCTURE MAY OCCUR BY THE OWNER'S REMOVAL AND SALVAGE OPERATIONS PRIOR TO START OF SELECTIVE DEMOLITION WORK.7. DAMAGESA. THE CONTRACTOR IS TO PROMPTLY REPAIR ALL DAMAGES CAUSED TO ADJACENT FACILITIES AND EQUIPMENT BY DEMOLITION WORK AT NO ADDITIONAL COST TO OWNER.SECTION 06 10 53 MISCELLANEOUS ROUGH CARPENTRY1. PRODUCT: WOOD GROUNDS, NAILERS, BLOCKING & BACKING PANELSA. LUMBER STANDARDS AND GRADE STAMPS: PS 20, AMERICAN SOFTWOOD LUMBER STANDARD AND INSPECTION AGENCY GRADE STAMPS.B. FIRE-RETARDANT TREATMENT: AWPA C20 FOR LUMBER AND AWPA C27 FOR PLYWOOD; NONCORROSIVE TYPEC. DIMENSION LUMBER: HEM-FIR, SELECT STRUCTURAL NO. 2SECTION 08 12 13 HOLLOW METAL FRAMES1. HEAVY DUTY INTERIOR FRAMES PER SDI 250.8A. PHYSICAL PERFORMANCE: LEVEL B PER SDI A250.4B. MATERIALS: UNCOATED STEEL SHEET, MINIMUM 0.053 INCHC. CONSTRUCTION: FULLY-WELDEDD. EXPOSED FINISH: PRIMESECTION 08 14 16 FLUSH WOOD DOORS1. INTERIOR FLUSH WOOD DOORSA. CORE: a. NON-RATED: PARTICLEBOARD COREb. FIRE-RATED: MINERAL CORE, POSITIVE PRESSURE AB. FACE: MDO, FACTORY PRIMEDC. GRADE: WDMA EXTRA HEAVY DUTYSECTION 08 80 00 GLAZING1. GLASS PRODUCTSA. FULLY TEMPERED FLOAT GLASS: ASTM C 1048, KIND FT (FULLY TEMPERED), CONDITION A (UNCOATED) UNLESS OTHERWISE INDICATED, TYPE 1, CLASS 1 (CLEAR), QUALITY Q3.2. GLASS SCHEDULE:A. MONOLITHIC-GLASS (TYPE S-1)a. CLEAR FULLY TEMPERED FLOAT GLASSb. THICKNESS: 6.0 MM (0.25 INCH)c. PROVIDE SAFETY LABELING, 16 CFR 1201, CATEGORY IISECTION 08 31 13 ACCESS DOORS AND FRAMES1. ACCESS DOORS FOR WALLS & CEILINGSA. FRAMES: 16 GA (.0598 INCH) SHEET STEEL WITH FLANGE SUITABLE FOR ADJACENT MATERIALB. DOORS: 14 GA (.0625 INCH) SHEET STEELC. DOOR TYPE: FLUSH PANELD. FIRE RATING: NFPA 80SECTION 08 71 00 DOOR HARDWARE1. SUBMITTALS:A. PRODUCT DATA: MANUFACTURER'S PRODUCT DATA SHEETS INCLUDING INSTALLATION DETAILS, MATERIAL DESCRIPTIONS, DIMENSIONS OF INDIVIDUAL COMPONENTS AND PROFILES, OPERATIONAL DESCRIPTIONS AND FINISHES.B. DOOR HARDWARE SCHEDULE: PREPARED BY OR UNDER THE SUPERVISION OF SUPPLIER, DETAILING FABRICATION AND ASSEMBLY OF DOOR HARDWARE, AS WELL AS PROCEDURES AND DIAGRAMS. COORDINATE THE FINAL DOOR HARDWARE SCHEDULE WITH DOORS, FRAMES, AND RELATED WORK TO ENSURE PROPER SIZE, THICKNESS, HAND, FUNCTION, AND FINISH OF DOOR HARDWARE.2. WARRANTY:A. SPECIAL WARRANTY PERIODS:1.TEN YEARS FOR MORTISE LOCKS AND LATCHES.2.FIVE YEARS FOR EXIT HARDWARE.3.TEN YEARS FOR MANUAL SURFACE DOOR CLOSERS.4.TWO YEARS FOR ELECTROMECHANICAL DOOR HARDWARE3. MAINTENANCE SERVICE:A. CONTINUING SERVICE: BEGINNING AT SUBSTANTIAL COMPLETION, AND RUNNING CONCURRENT WITH THE SPECIFIED WARRANTY PERIOD, PROVIDE CONTINUOUS (6) MONTHS FULL MAINTENANCE INCLUDING REPAIR AND REPLACEMENT OF WORN OR DEFECTIVE COMPONENTS, LUBRICATION, CLEANING, AND ADJUSTING AS REQUIRED FOR PROPER DOOR OPENING OPERATION. PROVIDE PARTS AND SUPPLIES AS USED IN THE MANUFACTURE AND INSTALLATION OF ORIGINAL PRODUCTS.4. PRODUCTS: PROVIDE PRODUCTS INDICATED IN HARDWARE SCHEDULE. NO SUBSTITUTIONS PERMITTED.SECTION 08 88 13 FIRE-RESISTANT GLAZING1. GLASS PRODUCTSA. LAMINATED CERAMIC GLAZING: LAMINATED GLASS MADE FROM TWO PLIES OF CLEAR, CERAMIC GLASS2. GLASS SCHEDULE:A. LAMINATED CERAMIC GLAZING (TYPE S-2)a. 45 MINUTE FIRE-PROTECTION RATED LAMINATED CERAMIC GLASSb. THICKNESS: 8.0 MMc. PROVIDE SAFETY LABELING, 16 CFR 1201, CATEGORY IId. PRODUCTS: SUBJECT TO COMPLIANCE WITH THE REQUIREMENTS;• SAFTI FIRST RATED GLAZING SOLUTIONS; PRYAN PLATINUM L• TECHNICAL GLASS PRODUCTS; FIRELITE PLUS• VETROTECH SAINT-GOBAIN; SGG KERALITE FR-LSECTION 09 51 13 ACOUSTICAL PANEL CEILINGSSECTION 09 65 13 RESILIENT BASE AND ACCESSORIESSECTION 09 65 19 RESILIENT TILE FLOORINGSECTION 10 14 00 SIGNS1. SUBMITTALSA. PRODUCT DATA: FOR EACH TYPE OF PRODUCT.B. SHOP DRAWINGS: FOR PANEL SIGNS.C. SAMPLES FOR INITIAL SELECTION: FOR EACH TYPE OF SIGN ASSEMBLY, EXPOSED COMPONENT, AND EXPOSED FINISH.a. INCLUDE REPRESENTATIVE SAMPLES OF AVAILABLE TYPESTYLES AND GRAPHIC SYMBOLS.D. SAMPLES FOR VERIFICATION: FULL-SIZE SAMPLE SHOWING ALL COMPONENTS AND WITH THE REQUIRED FINISH(ES)2. PANEL SIGNSA. PANEL SIGN: SIGN WITH SMOOTH, UNIFORM SURFACES; WITH MESSAGE AND CHARACTERS HAVING UNIFORM FACES, SHARP CORNERS, AND PRECISELY FORMED LINES AND PROFILES; AND AS FOLLOWS:B. SOLID-SHEET SIGN:ACRYLIC SHEET WITH FINISH SPECIFIED IN "SURFACE FINISH AND APPLIED GRAPHICS" SUBPARAGRAPH AND AS FOLLOWS:a. THICKNESS:MANUFACTURER'S STANDARD FOR SIZE OF SIGN.b. SURFACE-APPLIED, RAISED GRAPHICS: APPLIED POLYMER CHARACTERS AND BRAILLE.c. SIGN-PANEL PERIMETER: FINISH EDGES SMOOTH.d. CORNER CONDITION IN ELEVATION:SQUARE.e. MOUNTING:SURFACE MOUNTED TO WALL WITH ADHESIVE AND TWO-FACE TAPE.f. SURFACE FINISH AND APPLIED GRAPHICS:• INTEGRAL ACRYLIC SHEET COLOR:AS SELECTED BY ARCHITECT FROM FULL RANGE OF INDUSTRY COLORS.• TEXT AND TYPEFACE:ACCESSIBLE RAISED CHARACTERS AND BRAILLE AND VARIABLE CONTENT AS SCHEDULED.FINISH RAISED CHARACTERS TO CONTRAST WITH BACKGROUND COLOR, AND FINISH BRAILLE TO MATCH BACKGROUND COLOR. AS SELECTED BY ARCHITECT FROM FULL RANGE OF INDUSTRY COLORS.C. MATERIALSa. ACRYLIC SHEET: ASTM D 4802, CATEGORY AS STANDARD WITH MANUFACTURER FOR EACH SIGN, TYPE UVF (UV FILTERING).b. TWO-FACE TAPE: MANUFACTURER'S STANDARD HIGH-BOND, FOAM-CORE TAPE, 0.045 INCH THICK, WITH ADHESIVE ON BOTH SIDES.D. INSTALLATIONa. INSTALL SIGNS LEVEL, PLUMB, TRUE TO LINE, AND AT LOCATIONS AND HEIGHTS INDICATED, WITH SIGN SURFACES FREE OF DISTORTION AND OTHER DEFECTS IN APPEARANCE.E. SCHEDULEa. PROVIDE (1) SIGN FOR EACH DOOR NUMBERINDICATED ON PLANS.SECTION 12 24 13 ROLLER WINDOW SHADES1. MANUAL, CHAIN-AND-CLUTCH OPERATING MECHANISM A. ROLLER MOUNTING CONFIGURATION: SINGLE ROLLERB. INSTALLATION ACCESSORIES: FRONT FASCIA2. SHADEBAND MATERIALS: COMPLYING W/ NFPA 701A. LIGHT-FILTERING FABRIC: WOVEN POLYESTER AND PVC-COATED POLYESTER3. PRODUCT SAFETY STANDARD: WCMA A100.11. PRODUCTS:AS INDICATED IN FINISH SCHEDULE.2. INSTALLATION:INSTALL ACOUSTICAL PANEL CEILINGS ACCORDING TO ASTM C636/C636M AND MANUFACTURER'S WRITTEN INSTRUCTIONS.3. CLEANING: CLEAN EXPOSED SURFACES OF ACOUSTICAL PANEL CEILINGS, INCLUDING TRIM, EDGE MOLDINGS, AND SUSPENSION-SYSTEM MEMBERS. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR CLEANING AND TOUCHUP OF MINOR FINISH DAMAGE.REMOVE AND REPLACE CEILING COMPONENTS THAT CANNOT BE SUCCESSFULLY CLEANED AND REPAIRED TO PERMANENTLY ELIMINATE EVIDENCE OF DAMAGE.1. PRODUCTS:AS INDICATED IN FINISH SCHEDULE.2. ADHESIVES: WATER-RESISTANT TYPE RECOMMENDED BY RESILIENT-PRODUCT MANUFACTURER FOR RESILIENT PRODUCTS AND SUBSTRATE CONDITIONS INDICATED.3. RESILIENT BASE INSTALLATIONA. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR INSTALLING RESILIENT BASE.B. APPLY RESILIENT BASE TO WALLS, COLUMNS, PILASTERS, CASEWORK AND CABINETS IN TOE SPACES, AND OTHER PERMANENT FIXTURES IN ROOMS AND AREAS WHERE BASE IS REQUIRED.C. INSTALL RESILIENT BASE IN LENGTHS AS LONG AS PRACTICAL WITHOUT GAPS AT SEAMS AND WITH TOPS OF ADJACENT PIECES ALIGNED.D. TIGHTLY ADHERE RESILIENT BASE TO SUBSTRATE THROUGHOUT LENGTH OF EACH PIECE, WITH BASE IN CONTINUOUS CONTACT WITH HORIZONTAL AND VERTICAL SUBSTRATES.E. ON MASONRY SURFACES OR OTHER SIMILAR IRREGULAR SUBSTRATES, FILL VOIDS ALONG TOP EDGE OF RESILIENT BASE WITH MANUFACTURER'S RECOMMENDED ADHESIVE FILLER MATERIAL.F. JOB-FORMED CORNERS:USE STRAIGHT PIECES OF MAXIMUM LENGTHS POSSIBLE AND FORM WITH RETURNS NOT LESS THAN 3 INCHES IN LENGTH.MITER OR COPE CORNERS TO MINIMIZE OPEN JOINTS.4. RESILIENT ACCESSORY INSTALLATIONA. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR INSTALLING RESILIENT ACCESSORIES.B. RESILIENT MOLDING ACCESSORIES: BUTT TO ADJACENT MATERIALS AND TIGHTLY ADHERE TO SUBSTRATES THROUGHOUT LENGTH OF EACH PIECE. INSTALL REDUCER STRIPS AT EDGES OF FLOOR COVERING THAT WOULD OTHERWISE BE EXPOSED.5. CLEANING AND PROTECTIONA. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR CLEANING AND PROTECTING RESILIENT PRODUCTS.B. REMOVE ADHESIVE AND OTHER BLEMISHES FROM SURFACES OPERATIONS IMMEDIATELY AFTER COMPLETING RESILIENT-PRODUCT INSTALLATION.C. PROTECT RESILIENT PRODUCTS FROM MARS, MARKS, INDENTATIONS, AND OTHER DAMAGE FROM CONSTRUCTION OPERATIONS AND PLACEMENT OF EQUIPMENT AND FIXTURES DURING REMAINDER OF CONSTRUCTION PERIOD.D. COVER RESILIENT PRODUCTS SUBJECT TO WEAR AND FOOT TRAFFIC UNTIL SUBSTANTIAL COMPLETION.1. PRODUCTS:AS INDICATED IN FINISH SCHEDULE.2. INSTALLATION MATERIALSA. TROWELABLE LEVELING AND PATCHING COMPOUNDS: LATEX-MODIFIED, PORTLAND-CEMENT-BASED OR BLENDED HYDRAULIC-CEMENT-BASED FORMULATION PROVIDED OR APPROVED BY FLOOR TILE MANUFACTURER FOR APPLICATIONS INDICATED.B. ADHESIVES: WATER-RESISTANT TYPE RECOMMENDED BY FLOOR TILE AND ADHESIVE MANUFACTURERS TO SUIT FLOOR TILE AND SUBSTRATE CONDITIONS INDICATED.3. INSTALLATION:A. PREPARE SUBSTRATES ACCORDING TO FLOOR TILE MANUFACTURER'S WRITTEN INSTRUCTIONS TO ENSURE ADHESION OF RESILIENT PRODUCTS.B. CONCRETE SUBSTRATES: PREPARE ACCORDING TO ASTM F710.C. FILL CRACKS, HOLES, AND DEPRESSIONS IN SUBSTRATES WITH TROWELABLE LEVELING AND PATCHING COMPOUND; REMOVE BUMPS AND RIDGES TO PRODUCE A UNIFORM AND SMOOTH SUBSTRATE.D. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR INSTALLING FLOOR TILE.E. COVER FLOOR SUBJECT TO WEAR AND FOOT TRAFFIC TILE UNTIL SUBSTANTIAL COMPLETION.SECTION 07 84 13 PENETRATION FIRESTOPPINGA. FOR PENETRATIONS IN FIRE-RESISTANCE-RATED WALLS: PENETRATION FIRESTOPPING SYSTEMS WITH RATINGS DETERMINED PER ASTME814 OR UL1479, BASED ON TESTING AT A POSITIVE PRESSURE DIFFERENTIAL OF 0.01-INCH WG.1. F-RATING: NOT LESS THAN THE FIRE-RESISTANCE RATING OF CONSTRUCTIONS PENETRATED.B. ACCESSORIES: PROVIDE COMPONENTS FOR EACH PENETRATION FIRESTOPPING SYSTEM THAT ARE NEEDED TO INSTALL FILL MATERIALS AND TO MAINTAINRATINGS REQUIRED. USE ONLY THOSE COMPONENTS SPECIFIED BY PENETRATION FIRESTOPPING SYSTEM MANUFACTURER AND APPROVED BY QUALIFIED TESTING AND INSPECTING AGENCY FOR CONDITIONS INDICATED.1. PERMANENT FORMING/DAMMING/BACKING MATERIALS.2. SUBSTRATE PRIMERS.3. COLLARS.4. STEEL SLEEVES.C. INSTALL PENETRATION FIRESTOPPING SYSTEMS TO COMPLY WITH MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS AND PUBLISHED DRAWINGS FOR PRODUCTS AND APPLICATIONS.D. INSTALL FILL MATERIALS BY PROVEN TECHNIQUES TO PRODUCE THE FOLLOWING RESULTS:1. FILL VOIDS AND CAVITIES FORMED BY OPENINGS, FORMING MATERIALS, ACCESSORIES AND PENETRATING ITEMS TO ACHIEVE REQUIRED FIRE-RESISTANCE RATINGS.2. APPLY MATERIALS SO THEY CONTACT AND ADHERE TO SUBSTRATES FORMED BY OPENINGS AND PENETRATING ITEMS.3. FOR FILL MATERIALS THAT WILL REMAIN EXPOSED AFTER COMPLETING THEWORK, FINISH TO PRODUCE SMOOTH, UNIFORM SURFACES THAT ARE FLUSH WITH ADJOINING FINISHES.SECTION 12 36 53 LABORATORY WORK SURFACES1. PRODUCT: EPOXY RESIN WORK SURFACEA. BASIS OF DESIGN MANUFACTURER: DURCON, INC2. MATERIAL: SOLID EPOXY RESINA. SHEETS CAST FROM MODIFIED EPOXY RESIN AND NON-ASBESTOS INERT FILLERB. SHEET MONOLITHIC THROUGHOUT WITHOUT SURFACE COATING APPLICATION3. COLOR: BLACK ONYX4. FABRICATION: EPOXY RESIN WORK SURFACEA. THICKNESS: 1"B. EDGE TREATMENT: 1/8" BEVEL W/ DRIP GROOVEC. CORNER TREATMENT: EXPOSED CORNERS SHALL BE EASED SLIGHTLY FOR SAFETYD. BACK AND END SPLASHES:1. SUPPLIED LOOSE FOR FIELD INSTALLATION2. SAME MATERIAL AND THICKNESS AS WORK SURFACE3. 4" HIGH UNLESS OTHERWISE NOTED4. TOP-MOUNTED END SPLASH WHERE WORK SURFACES ABUT ADJACENT CONSTRUCTION AND AT LOCATIONS INDICATED ON DRAWINGSE. JOINTS: AS INDICATED ON DRAWINGS, MAXIMUM 1/8" BONDED WITH EPOXY GROUTF. SINK CUTOUTS: AS INDICATED ON DRAWINGS, ROUTED FOR DROP-IN SINKG. ALLOWABLE TOLERANCES:a. SQUARE: PLUS OR MINUS 1/64" FOR EACH 12" OF LENGTHb. LOCATION OF CUTOUTS AND DRILLED OPENINGS: PLUS OR MINUS 1/8" OF DESIGN DIMENSIONc. SIZE OF CUTOUTS OR DRILLED OPENINGS: PLUS 1/8" OR MUNS 0"5. FABRICATION: EPOXY RESIN SINKA. MOLD SINKS FROM THERMOSETTING EPOXY RESINB. MOLD INTERIOR CORNERS TO RADIUS. SLOPE SINK BASE TO DRAIN OUTLET.C. PROVIDE 1-1/2" OUTLET WITH OPEN ENDED STANDPIPE; STANDPIPE OVERFLOW 2" SHORTER THAN DEPTH OF SINKD. UNLESS OTHERWISE INDICATED, FABRICATE SINKS OF DROP-IN SUPPORT BY UPPER FLANGE FROM WORK SURFACE.E. COLOR: TO MATCH ADJACENT WORK SURFACES.F. SINK TYPES:a. SK-A: D-25 (18" X 15" X 7.9")b. SK-B: A-25 (18" X 15" X 5")c. SK-C: D-05 (14" X 10" X 6.3")d. SK-D: D-25 (18" X 15" X 7.9")e. SK-E: D-32 (18" X 15" X 15.13")f. SK-F: A-25 (18" X 15" X 5")g. SK-G: D-58 (25" X 15" X 17.75")6. FABRICATION: EPOXY RESIN CUPSINKSA. BASIS OF DESIGN: TS05B. SHAPE: OVALC. COLOR: BLACKSECTION 11 53 13 LABORATORY FUME HOODS1. PRODUCT: FUME HOODA. ACCEPTABLE MANUFACTURERS & PRODUCTS (PROVIDE ONE OF THE FOLLOWING, NO SUBSTITUTIONS):a. BOD: MOTT DEEP FULLY ACCESSIBLE -COMBINATION SASH, MOTT 5' SAFEGUARD BENCH LABORATORY HOOD, 32.7" EXTERIOR, MODEL #7341050b. LABCONCO PROTECTOR XL LABORATORY HOODc. BEDCOLAB FULLY ACCESSIBLE FUME HOOD MODEL VBHB. TYPE: FULLY ACCESSIBLE RESTRICTED BY-PASSC. CONTAINMENT: AVERAGE FACE VELOCITY 100 FPM +/-10% WITH SASHES AT 18-ICHES OPEN WHEN TESTED ACCORDING TO ASHRAE 110 AT A RELEASE RATE OF 4.0 L/MIND. MATERIALS:a. FRP SURROUND: ALL STEEL COMPONENTS TO BE POWDER COATED (GLACIER WHITE)b. WORKSURFACE: BLACK EPOXY #9521520E. SASH: VERTICAL TRAVEL OR COMBINATION (MOTT ONLY); TEMPERED SAFETY GLASS; COUNTER WEIGHTED AND BALANCED; PULLEY SYSTEM; STAINLESS STEEL SASH STOPS; SASH ALARM BY BACS CONTRACTORF. ELECTRICAL FIXTURES (PROVIDE ALL WIRING WITHIN HOOD)a. FLUORESCENT LIGHT AND TUBES WITH SWITCHb. DUPLEX, 115 VAC/60Hz/20A/GFCIG. SERVICE FIXTURES (ADA COMPLIANT LEVER HANDLE REMOTE CONTROL VALVES); PROVIDE ALL FIXTURES AND PIPING ON AND WITHIN HOOD:a. COLD WATER (LEFT SIDE; REFER TO FUME HOOD SCHEDULE)b. COMPRESSED AIR W/ 1/4" QUICK CONNECT (LEFT SIDE, REFER TO FUME HOOD SCHEDULE)H. SINK: CUP SINK, REFER TO SECTION 12 36 53I. OTHER FEATURES: AERODYNAMIC AIRFOIL BYPASS WITH SPILL THROUGHJ. BASE/STAND: 5 FT ELECTRIC HYDRAULIC LIFT BASE STAND; 115 VAC / 60 HZa. BOD: LABCONCO #3780106SECTION 12 35 51 LABORATORY CASEWORK1. PRODUCT: CABINETSA. MANUFACTURER: MOTT MANUFACTURINGB. PERFORMANCE REQUIREMENTS: COMPLY WITH SEFA 8 RECOMMENDED PRACTICESC. PRODUCT: STEEL CABINETSa. CABINETS:• CABINET SIDES: 18 GA• TOP RAILS: 14 GA• DOOR FRONTS: 18GA• RUBBER BUMPERS/SILENCERS• ADJUSTABLE SHELVES: 20GA• PULLS: 4" STAINLESS STEEL WIRE PULL• HINGES: STAINLESS STEEL OVERLAY HINGES• STEEL FINISH: POWDER COATEDb. BASE CABINET• REMOVABLE BACK: 20 GA• REAR RAIL: 16 GA• DRAWER RUNNER SUPPORT: 14 GA GALVANIZED• DRAWER LINER: 20 GA• ROLLER CATCHES• 3/8" THREADED LEVELER PLATE: 11 GA• DRAWER WITH INTEGRAL SIDES & BACK: 18 GA OR 20 GA• ENCLOSED TOE SPACE: 18 GAc. UPPER CABINET• GLAZED DOORS: HOLLOW-METAL STILES AND RAILS. GLASS HELD IN RESILIENT CHANNELS OR GASKET MATERIALD. PRODUCT: WOOD CABINETSa. CABINETS:• DESIGN: REVEAL OVERLAY WITH SQUARE EDGES1. PROVIDE 1/8-INCH REVEALS BETWEEN DOORS AND DRAWERS THAT ARE ADJACENT• WOOD SPECIES: AS SELECTED BY ARCHITECT1. WOOD STAIN COLORS AND FINISHES: AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL RANGE.• CUT: QUARTER SLICED/SAWN• VENEER MATCHING: PROVIDE VENEERS FOR EACH CABINET FROM A SINGLE FLITCH, SLIP AND RUNNING MATCHED.1. PROVIDE CONTINUOUS MATCHING OF ADJACENT DRAWER FRONTS WITHIN EACH CABINET • GRAIN DIRECTION:1. DOORS: VERTICAL WITH CONTINUOUS VERTICAL MATCHING2. DRAWER FRONTS: VERTICAL WITH CONTINUOUS VERTICAL MATCHING3. FACE FRAME MEMBERS: LENGTHWISE4. END PANELS: VERTICAL5. BOTTOMS AND TOPS OF UNITS: SIDE TO SIDE6. APRONS: HORIZONTAL• MATERIALS: 1. EXPOSED: HARDWOOD PLYWOOD, VENEER CORE WITH FACE VENEER OF SPECIES INDICATED. GRADE A EXPOSED FACES, AT LEAST 1/50 IN THICK AND GRADE J CROSSBANDS. PROVIDE BACKS OF SAME SPECIES AS FACES. SOLID WOOD, CLEAR HARDWOOD LUMBER OF SPECIES INDICATED.2. SEMIEXPOSED: GRADE B SEMIEXPOSED FACES AND GRADE J CROSSBANDS OF SAME SPECIES AS EXPOSED PLYWOOD. PROVIDE BACKS OF SAME SPECIES AS FACES. SOLID WOOD, SOUND HARDWOOD LUMBER, SELECTED TO ELIMINATE APPEARANCE OF DEFECT, OF SAME SPECIES AS EXPOSED SOLID WOOD.3. CONCEALED: HARDWOOD PLYWOOD. PROVIDE BACKS OF SAME SPECIES AS FACES. SOLID WOOD, WITH NO DEFECTS AFFECTING STRENGTH OR UTILITY• ROLLER CATCHES• RUBBER BUMPERS/SILENCERS• PULLS: 4" STAINLESS STEEL WIRE PULL• BUTT HINGES: STAINLESS STEEL FIVE-KNUCKLE HINGES. PROVIDE 2 PER DOORE. PRODUCT: REAGENT SHELVING SYSTEMa. FABRICATED FROM COLD-ROLLED, COMMERCIAL STEEL SHEET MATERIAL IN MANUFACTURER'S STANDARD METAL THICKNESS. PROVIDE UPRIGHTS WITH ADJUSTABLE SHELVES.F. PRODUCT: PEG BOARDSa. POLYPROPYLENE, EPOXY OR PHENOLIC-COMPOSITE PEGBOARDS WITH REMOVABLE POLYPROPYLENE PEGS AND STAINLESS-STEEL DRIP TROUGHS WITH DRAIN OUTLET.G. MARBLE SLAB TABLEa. CONSTRUCTED FROM 3" THICK SOLID MARBLE SLABS WITH EASED EDGES. SOLID TOP AND SUPPORTING PANELS WITH STEEL OR IRON CROSS BEAM COATED FOR CORROSION RESISTANCE.b. BASIS OF DESIGN: VWR 12568-004SECTION 09 91 23 INTERIOR PAINTING1. PRODUCTS: A. GENERAL:a. MATERIALS FOR USE WITHIN EACH PAINT SYSTEM SHALL BE COMPATIBLE WITH ONE ANOTHER AND SUBSTRATES INDICATED, UNDER CONDITIONS OF SERVICE AND APPLICATION AS DEMONSTRATED BY MANUFACTURER, BASED ON TESTING AND FIELD EXPERIENCEb. FOR EACH COAT IN A PAINT SYSTEM, PRODUCTS SHALL BE RECOMMENDED IN WRITING BY TOPCOAT MANUFACTURERS FOR USE IN PAINT SYSTEM AND ON SUBSTRATE INDICATED.B. INTERIOR PRIMERS:a. INTERIOR GYPSUM BOARD PRIMER: FACTORY-FORMULATED LATEX-BASED PRIMER FOR INTERIOR APPLICATION• BENJAMIN MOORE; MOORCRAFT SUPER SPEC LATEX ENAMEL UNDERCOATER & PRIMER SEALER 253; APPLIED AT A DRY FILM THICKNESS OF NOT LESS THAN 1.2 MILS.b. INTERIOR FERROUS-METAL PRIMER: FACTORY-FORMULATED QUICK-DRYING RUST-INHIBITIVE ALKYD-BASED METAL PRIMER• BENJAMIN MOORE; MOORCRAFT SUPER SPEC ALKYD ENAMEL UNDERBODY AND PRIMER SEALER C245; APPLIED AT A DRY FILM THICKNESS OF NOT LESS THAN 1.5 MILS. C. INTERIOR FINISH COATS:a. INTERIOR FLAT ACRYLIC PAINT: FACTORY-FORMULATED FLAT LATEX PAINT FOR INTERIOR APPLICATION• BENJAMIN MOORE: MOORCRAFT SUPER SPEC LATEX FLAT 275: APPLIED AT A DRY FILM THICKNESS OF NOT LESS THAN 1.2 MILS.b. INTERIOR SEMIGLOSS ACRYLIC ENAMEL: FACTORY-FORMULATED SEMIGLOSS LATEX ENAMEL FOR INTERIOR APPLICATION:• BENJAMIN MOORE: MOORCRAFT SUPER SPEC LATEX SEMI-GLOSS ENAMEL 276: APPLIED AT A DRY FILM THICKNESS OF NOT LESS THAN 1.2 MILS.2. SUBMITTALSA. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INCLUDE PREPARATION REQUIREMENTS AND APPLICATION INSTRUCTIONS.3. EXAMINATION:A. EXAMINE SUBSTRATES AND CONDITIONS, WITH APPLICATOR PRESENT, FOR COMPLIANCE WITH REQUIREMENTS FOR MAXIMUM MOISTURE CONTENT AND OTHER CONDITIONS AFFECTING PERFORMANCE OF THE WORK.B. GYPSUM BOARD SUBSTRATES: VERIFY THAT FINISHING COMPOUND IS SANDED SMOOTHC. VERIFY SUITABILITY OF SUBSTRATES, INCLUDING SURFACE CONDITIONS AND COMPATIBILITY, WITH EXISTING FINISHES AND PRIMERS.D. PROCEED WITH COATING APPLICATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTEDa. APPLICATION OF COATING INDICATES ACCEPTANCE OF SURFACES AND CONDITIONS4. PREPARATION:A. COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS IN "MPI ARCHITECTURAL PAINTING SPECIFICATION MANUAL" APPLICABLE TO SUBSTRATES AND PAINT SYSTEMS INDICATED.B. REMOVE HARDWARE, COVERS, PLATES, AND SIMILAR ITEMS ALREADY IN PLACE THAT ARE REMOVABLE AND RE NOT TO BE PAINTED. IF REMOVAL IS IMPRACTICAL OR IMPOSSIBLE BECAUSE OF SIZE OR WEIGHT OF ITEM, PROVIDE SURFACE-APPLIED PROTECTION BEFORE SURFACE PREPARATION AND PAINTING.a. AFTER COMPLETING PAINTING OPERATIONS, USE WORKERS SKILLED IN THE TRADES INVOLVED TO REINSTALL ITEMS THAT WERE REMOVED. REMOVE SURFACE-APPLIED PROTECTION IF ANY.C. CLEAN SUBSTRATES OF SUBSTANCES THAT COULD IMPAIR BOND OF PAINTS, INCLUDING DUST, DIRT, OIL, GREASE AND INCOMPATIBLE PAINTS AND ENCAPSULANTS.a. REMOVE INCOMPATIBLE PRIMERS AND REPRIME SUBSTRATE WITH COMPATIBLE PRIMERS OR APPLY TIE COAT AS REQUIRED TO PRODUCE PAINT SYSTEMS INDICATED.D. CONCRETE SUBSTRATES: REMOVE RELEASE AGENTS, CURING COMPOUNDS, EFFLORESCENCE AND CHALK. DO NOT PAINT SURFACES IF MOISTURE CONTENT OR ALKALINITY OF SURFACES TO BE PAINTED EXCEEDS THAT PERMITTED IN MANUFACTURER'S WRITTEN INSTRUCTIONS.5. APPLICATION:A. APPLY PAINTS ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS AND TO RECOMMENDATIONS IN "MPI MANUAL"a. USE APPLICATORS AND TECHNIQUES SUITED FOR PAINT AND SUBSTRATE INDICATED.b. PAINT SURFACES BEHIND MOVABLE EQUIPMENT AND FURNITURE SAME AS EXPOSED SURFACESc. PAINT FRONT AND BACKSIDES OF ACCESS PANELS, REMOVABLE OR HINGED COVERS, AND SIMILAR HINGED ITEMS TO MATCH EXPOSED SURFACESd. DO NOT PAINT OVER LABELS OF INDEPENDENT TESTING AGENCIES OR EQUIPMENT NAME, IDENTIFICATION, PERFORMANCE RATING OR NOMENCLATURE PLATES.B. TINT EACH UNDERCOAT A LIGHTER SHADE TO FACILITATE IDENTIFICATION OF EACH COAT IF MULTIPLE COATS OF SAME MATERIAL ARE TO BE APPLIED. TINT UNDERCOATS TO MATCH COLOR OF TOPCOAT, BUT PROVIDE SUFFICIENT DIFFERENCE IN SHADE OF UNDERCOATS TO DISTINGUISH EACH SEPARATE COAT.C. IF UNDERCOATS OR OTHER CONDITIONS SHOW THROUGH TOPCOAT, APPLY ADDITIONAL COATS UNTIL CURED FILM HAS A UNIFORM PAINT FINISH, COLOR AND APPEARANCE.D. APPLY PAINTS TO PRODUCE SURFACE FILMS WITHOUT CLOUDINESS, SPOTTING, HOLIDAYS, LAPS, BRUSH MARKS, ROLLER TRACKING, RUNS, SAGS, ROPINESS OR OTHER SURFACE IMPERFECTIONS. CUT IN SHARP LINES AND COLOR BREAKS.E. PAINTING FIRE SUPPRESSION, PLUMBING, HVAC, ELECTRICAL, COMMUNICATION AND ELECTRONIC SAFETY AND SECURITY WORK:a. PAINT THE FOLLOWING WORK WHERE EXPOSED IN OCCUPIED SPACES:• EQUIPMENT, INCLUDING PANELBOARDS• UNINSULATED METAL PIPING• UNINSULATED PLASTIC PIPING• PIPE HANGERS AND SUPPORTS• METAL CONDUIT• PLASTIC CONDUIT• DUCT, EQUIPMENT AND PIPE INSULATION HAVING COTTON OR CANVAS INSULATION COVERING OR OTHER PAINTABLE JACKET MATERIAL• OTHER ITEMS AS DIRECTED BY ARCHITECTb. PAINT PORTIONS OF INTERNAL SURFACES OF METAL DUCTS, WITHOUT LINER, BEHIND AIR INLETS AND OUTLETS THAT ARE VISIBLE FROM OCCUPIED SPACES.6. CLEANING AND PROTECTIONA. AT END OF EACH WORKDAY, REMOVE RUBBISH, EMPTY CANS, RAGS AND OTHER DISCARDED MATERIALS FROM PROJECT SITE.B. AFTER COMPLETING PAINTING APPLICATION, CLEAN SPATTERED SURFACES. REMOVE SPATTER PAINTS BY WASHING, SCRAPING OR OTHER METHODS. DO NOT SCRATCH OR DAMAGE ADJACENT FINISHED SURFACES.C. PROTECT WORK OF OTHER TRADES AGAINST DAMAGE FROM PAINT APPLICATION. CORRECT DAMAGE TO WORK OF OTHER TRADES BY CLEANING, REPAIRING, REPLACING AND REFINISHING, AS APPROVED BY ARCHITECT, AND LEAVE IN AN UNDAMAGED CONDITION.D. AT COMPLETION OF CONSTRUCTION ACTIVITIES OR OTHER TRADES, TOUCH UP AND RESTORE DAMAGED OR DEFACED PAINTED SURFACES.7. INTERIOR PAINTING SCHEDULEA. GYPSUM BOARD: PROVIDE THE FOLLOWING FINISH SYSTEMS OVER INTERIOR GYPSUM BOARD SURFACES:a. SEMIGLOSS ACRYLIC ENAMEL FINISH: TWO FINISH COATS OVER A PRIMER• PRIMER: INTERIOR GYPSUM BOARD PRIMER• FINISH COATS: WATERBORNE ACRYLIC EPOXY.B. FERROUS METAL: PROVIDE THE FOLLOWING FINISH SYSTEMS OVER FERROUS METAL:a. SEMIGLOSS ACRYLIC-ENAMEL FINISH: TWO FINISH COATS OVER A PRIMER• PRIMER: INTERIOR FERROUS-METAL PRIMERFINISH COATS: INTERIOR SEMIGLOSS ACRYLIC ENAMELSECTION 06 25 30 SLATWALL PANEL SYSTEMS1. MATERIAL: ANCHOR CORE FIREWALL-FR AS MANUFACTURED BY BOISE CASCADE OR EQUIVALENTA. PANEL CONFIGURATION: ENGINEERED GROOVE MACHINED INTO WOOD 3/4-INCH-THICK COMPOSITE SUBSTRATEB. GROOVE PATTERN: 6 INCHES ON CENTER, ORIENTED HORIZONTALC. ALUMINUM INSERTS: .036-INCH MILL FINISHED ALUMINUM INSERTSD. ALUMINUM TRIM: 3/4-INCH MILL FINISH J TRIM AT TOP, BOTTOM AND SIDE EDGESE. PANEL FINISH: PAINTEDThese documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. ©387 East Main Street Rochester NY 14604585 232 8300 | rochester@swbr.comFILE PATH:SWBR Project NumberChecked By:Project Manager:Drawn By:Revisions3/15/2021 3:42:45 PMBIM 360://20636.00 Cornell Corson Hall E303-E347/Cornell Corson Hall E303 E304 E305 E347 Lab and Office Renovation.rvt20636.00CWJSpecificationsCWJCREA-604100% ConstructionDocumentsCornell UniversityCorson Hall Third FloorLaboratory & Office RenovationIthaca, NYMarch 5, 2021 WALL HYDRANT (WH) / HOSE BIBB (HB) VENT PIPING PRESSURE GAUGE THERMOMETER SHOCK ABSORBER (SA) BACKFLOW PREVENTER (BFP) UNION RELIEF VALVE PRESSURE REDUCING VALVE SOLENOID VALVE CHECK VALVE BALANCING VALVE SHUT OFF VALVE INDIRECT WASTE PIPING (IW)IW FLOOR DRAIN (FD) / FLOOR SINK (FS) CLEANOUT (CO) WALL PLATE CLEANOUT (WPCO) DECK PLATE CLEANOUT (DPCO) CAP OR PLUG PIPE CONTINUATION "P" TRAP TOP TEE CONNECTION BOTTOM/TEE CONNECTION ELBOW UP 45°OFFSET ELBOW DOWN DESCRIPTION PLUMBING SYMBOL LIST SYMBOL COMPRESSED AIR PIPING (CA)CA NATURAL GAS PIPING (G)G LAB VENT PIPING (LV)LV STRAINER LAB WASTE PIPING (LW)LW SANITARY SEWER PIPINGSAN DIR DEIONIZED WATER RETURN PIPING (DIR) DEIONIZED WATER PIPING (DI)DI TEMPERED HOT WATER RETURN PIPING (TWR)TWR TEMPERED HOT WATER PIPING (TW)TW HOT WATER RECIRCULATING PIPING (HWR) HOT WATER PIPING (HW) COLD WATER PIPING (CW) NEW PIPING LOCATED BELOW FLOOR/SLAB NEW PIPING LOCATED ABOVE FLOOR/SLAB (E)EXISTING PIPING EC ELECTRICAL CONTRACTOR PC PLUMBING CONTRACTOR MC MECHANICAL CONTRACTOR GC GENERAL CONTRACTOR VTR VENT THRU ROOF BFF BELOW FINISHED FLOOR AFF ABOVE FINISHED FLOOR (ETR)EXISTING TO REMAIN (E)EXISTING NTS NOT TO SCALE POINT OF DISCONNECTION POINT OF CONNECTION EXISTING WORK TO BE REMOVED DRAWING KEYNOTE DEMOLITION/REMOVAL KEYNOTE X X DETAIL NOTES: DOMESTIC COLD WATER FLOW DIRECTION LABEL. PROVIDE 360 DEGREE WRAP OVERLAPPING BOTH ENDS OF THE PIPE FUNCTION LABEL AND MATCHING THE FLOW DIRECTION OF THE PIPE CONTENTS. PIPE FUNCTION LABEL A. B. C. D. E. F. PROVIDE A PIPE LABEL FOR EACH PIPE FUNCTION. PROVIDE AT LEAST ONE LABEL ON EACH PIPE FOR EVERY ROOM THE PIPE PASSES THROUGH. PROVIDE LABELS IN LARGE SPACES ON MAXIMUM 20' CENTERS FOR EVERY PIPE UNLESS OTHERWISE NOTED IN THE SPECIFICATIONS. LABELS TO BE LOCATED IN AN EASILY VISIBLE LOCATION AS THEY WOULD NORMALLY BE SEEN. IE. ON THE BOTTOM HALF OF PIPES IN THE AIR AND ON THE TOP HALF OR SIDES OF PIPES MOUNTED LOW. LABELS SHALL BE, COLOR CODED, PRE-PRINTED, SELF ADHESIVE VINYL. SEE SPECIFICATION FOR OTHER REQUIREMENTS AND LIST OF PIPE FUNCTIONS. PRESSURE REGULATING VALVE SET PER END USERS TO SYSTEM MANIFOLD DESIGN BASIS: HARRIS MANIFOLD MODEL #SG900 SS 2'-0" FLEXIBLE STAINLESS STEEL PIGTAIL (TYPICAL) WALL BRACKET CYLINDER RESTRAINTS CYLINDER BY OWNER FINISHED FLOOR 1/2" STAINLESS STEEL HEADER STAINLESS STEEL CHECK VALVE (TYPICAL)5'-0" AFFDETAIL NOTES: A. REFER TO LAB PLANS FOR SPECIFIC GAS REQUIRED. DETAIL NOTES: FUME HOOD WORK SURFACE AT NON ADA HEIGHT, 36 INCHES ABOVE FINISHED FLOOR. FUME HOOD WORK SURFACE AT ADA HEIGHT, 30 INCHES ABOVE FINISHED FLOOR. PROVIDE 2" DRUM TRAP. PROVIDE SUFFICIENT PIPE ON INLET TO ALLOW 6" OF WORK SURFACE ADJUSTMENT. PROVIDE 1 1/2" DRAIN FROM CUP SINK. PROVIDE SUFFICIENT TAILPIECE ON OUTLET TO ALLOW FOR 6" OF WORK SURFACE ADJUSTMENT. DRAIN IS TO BE SLEEVED WITHIN THE 2" INLET PIPE PROVIDED ON THE DRUM TRAP. 2" DRAIN, ROUTE BEHIND UNIT IN CHASE SPACE AND CONNECT TO SINK DRAIN PROVIDE 1 1/2" ACID VENT SERVING CUP SINK DRAIN. CONNECT TO NEAREST VENT SERVICE AS INDICATED ON PLANS. COORDINATE WITH VENT FROM ADJACENT LABORATORY FIXTURES. DOMESTIC COLD WATER CONNECTION: PROVIDE BRASS/ STAINLESS STEEL FLEXIBLE CONNECTION TO PRE-PIPED LABORATORY DOMESTIC WATER SERVICE AT FT FUME HOOD. 1 2 3 4 5 6 7 LAB EXHAUST DUCT (TYP.) DUCT COLLAR (TYP.) FUME HOOD FUME HOOD 1 7 2 7 4 3 5 6 4 3 5 6 EMERGANCY EYEWASH. REFER TO PLANS FOR LEFT OR RIGHT HAND MODEL. 2" LAB WASTE. PIPING IN WALL. SINK TMV. REFER TO ASSOCIATED EYEWASH SPECIFICATION FOR TYPE.1/2" COLD WATER SUPPLY 1/2" HOT WATER SUPPLY 1/2" RODI WATER SUPPLY LAB VENT. REFER TO PLANS TO SEE IF INDIVIDUAL VENT IS REQUIRED. DI FAUCET PIPING IN WALL (TYP) NOTE: IF IN ADA CABINET, ALL PIPING SHALL MEET ANSI & ADA REQUIREMENTS FINISHED FLOOR CASEWORK SIGNAGE "GAS SHUTOFF" FINISHED FLOOR5'-6"REFER TO PLANS FOR LINE SIZE CEILING These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions3/10/2021 3:38:21 PMC:\Users\cmdoktor\Documents\200278_Corson3rdFloor_P_Central_R20_cmdoktor.rvt20636.00 THK General Notes And Symbols List GDD CMD P-000 100% Contsruction Documents Cornell University Corson Hall Third Floor Laboratory & Office Renovation Ithaca, NY March 5, 2021 NOT TO SCALE1PIPING IDENTIFICATION LABEL DETAIL THESE NOTES ARE APPLICABLE TO THE FULL SET OF CONTRACT DOCUMENTS. EXISTING CONDITIONS ARE TAKEN FROM FIELD OBSERVATIONS AND PRIOR CONSTRUCTION DOCUMENTS WHEN AVAILABLE. THE LOCATIONS SHOWN MUST BE CONSIDERED APPROXIMATE. OTHER SUCH WORK MAY EXIST, HOWEVER, LOCATION AND SIZE ARE NOT PRESENTLY KNOWN. IT IS STRONGLY ENCOURAGED TO VISIT SITE PRIOR TO BID TO REVIEW EXISTING CONDITIONS AND CONFIRM SCOPE OF WORK. WHEN EXISTING CONSTRUCTION IS DAMAGED DURING WORK BY THIS CONTRACTOR, REPAIR AND/OR REPLACE WITH SIMILAR MATERIALS AS MUCH AS POSSIBLE, SUBJECT TO ARCHITECTS APPROVAL. DISPOSE OF ALL DEMOLITION AND/OR OTHER WASTE MATERIALS CAUSED BY WORK OF THIS CONTRACTOR. LEGALLY DISPOSE ALL MATERIALS TO A LOCATION OFF SITE. COORDINATE AND SCHEDULE WORK AND SHUTDOWNS WITH THE OWNER AND OTHER TRADES PRIOR TO DEMOLITION. ALL EXISTING PIPING TO REMAIN SHALL BE RECONNECTED TO ACTIVE SERVICE PIPING. ALL PIPING TO BE REMOVED, SHALL BE REMOVED BACK TO ACTIVE PIPING AND CAPPED. VALVE AND CAP ALL WATER PIPING. REMOVE ALL INACTIVE PIPING UNLESS NOTED. ALL PIPING TO BE REMOVED AND LOCATED WITHIN A WALL TO REMAIN MAY BE ABANDONED IN PLACE UNLESS NOTED. REMOVE PIPING BACK TO BEHIND THE FINISHED WALL SURFACE AND CAP. PATCH HOLES IN EXISTING CONSTRUCTION LEFT BY THE REMOVAL OF PIPING OR EQUIPMENT WITH MATERIALS TO MATCH EXISTING CONSTRUCTION. MAINTAIN FIRE/SMOKE RATING. DEMOLITION SHALL INCLUDE, BUT NOT BE LIMITED TO: PIPING, VALVES, FIXTURES, EQUIPMENT, HANGERS, SUPPORTS, AND INSULATION EXCEPT ASBESTOS. REMOVE EXISTING CONSTRUCTION IN THE WAY OF NEW WORK. PROTECT BUILDING AND FURNISHINGS FROM DAMAGE. WHERE NEW WORK IS TO BE INSTALLED ABOVE AN EXISTING CEILING, PROVIDE FOR THE REMOVAL OF THE CEILING. UPON COMPLETION OF WORK, REPAIR ALL DAMAGED CEILING SURFACES, REPLACE ALL DAMAGED TILES. SLEEVE AND SEAL ALL WALL AND FLOOR PENETRATIONS. PROVIDE FIRESTOPPING FOR ALL PENETRATIONS. MAINTAIN SERVICE CLEARANCES OF ALL EQUIPMENT. ADVISE OTHER TRADES OF THE REQUIRED SERVICE CLEARANCES. PROVIDE FOR THE DRAINING AND REFILLING OF PIPING SYSTEMS, INCLUDING AIR REMOVAL, RESETTING OF FLUSH VALVES, FLUSHING SYSTEMS OF DIRT AND SCALE CAUSED BY SHUTDOWNS AND STARTUPS. REFER TO EQUIPMENT/ FIXTURE SCHEDULE FOR FINAL CONNECTION SIZES. PROVIDE CLEANOUTS AT THE BASE OF ALL STORM, SANITARY AND WASTE STACKS. PITCH 4" AND LARGER LAB WASTE PIPING AT 1/8" PER FOOT UNLESS OTHERWISE NOTED. FOR LAB WASTE PIPING 3" AND SMALLER PITCH AT 1/4" PER FOOT UNLESS OTHERWISE NOTED. A. B. C. D. E. F. G. H. I. J. K. L. M. N. O. P. Q. R. GENERAL NOTES: NOT TO SCALE2LAB GAS MANIFOLD DETAIL NOT TO SCALE4ADA FUME HOOD INSTALLATION DETAIL NOT TO SCALE3SINK WITH EYEWASH DETAIL 2 ACID WASH SINK, FOR ACID TUB, NO FAUCET. 1 REFER TO DETAIL 3 ON P-000. REMARKS: EW-A EYE WASH 1/2" TEPID ---1 SK-G SINK -- (2) 1 1/2" 2" 1 1/2"- SK-E SINK ---2" 1 1/2"2 SK-D SINK 1/2" 1/2" 1/2" 2" 1 1/2"- SK-B, SK-F SINK - ADA 1/2" 1/2" 1/2" 2" 1 1/2"- SK-A, SK-C SINK 1/2" 1/2" 1/2" 2" 1 1/2"- DESIGNATION DESCRIPTION COLD WATER HOT WATER DI WATER WASTE OR SANITARY VENT REMARKS FIXTURE AND EQUIPMENT CONNECTION SCHEDULE NOT TO SCALE5GAS SHUTOFF DN UP DN UP A C D F 12 13 14 15 16 17 E200C E221 E223 E225 E227E236 E236A E216A E216 E220 E217 E212 E242A E240 E242 E215E213E211E209 E205 E203 E206 E202B E202A E248A E244 E248B E248 E202 (E)4" (E)4" (E)4" (E)4" (E)LW (R)2" LW UP (R)2" LW UP (E)LW (E)4" LW (E)4" LV (E)5" ST (E)2" LW UP TO SINK (E)LW(E)2" LW UP (E)4" LW UP & DN (E)2" (E)4" (E)4" LV UP & DN (E)LV (E)2" A C D F H 12 13 14 15 16 17 E200C E221 E223 E225 E227 E236 E236A E216A E216 E220 E217 E212 E242A E240E242 E215E213E211E209 E205E203 E201 E206 E202B E202A E248A E244 E248B E248A200UG E202 2"(E)LW2" 2" LW UP TO THIRD FLOOR SINK 2" LW UP TO THIRD FLOOR SINK 2" LW UP TO THIRD FLOOR SINK (E)LW(E)LW(E)LW(E)4" LW (E)5" ST 4" 4" (E)4" LW (E)4" LV (E)5" ST 2" LW UP TO THIRD FLOOR SINK 2"(E)LW(E)2" LW UP (E)2" (E)4" (E)2" LW UP TO SINK (E)4" LW UP & DN (E)LV (E)2" (E)4" LV UP & DN 2" LW UP TO THIRD FLOOR SINK These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions3/10/2021 3:38:21 PMC:\Users\cmdoktor\Documents\200278_Corson3rdFloor_P_Central_R20_cmdoktor.rvt20636.00 THK Partial Second Floor Plans - Plumbing GDD CMD P-100 100% Contsruction Documents Cornell University Corson Hall Third Floor Laboratory & Office Renovation Ithaca, NY March 5, 2021 1/8" = 1'-0"1 Partial Second Floor Plan - Plumbing Demolition 1/8" = 1'-0"2 Partial Second Floor Plan - Plumbing C D F 15 16 17 18 (E)DIR(E)DI(E)G(E)CA ●●● ●●●●●●CA GDI ●●● ●●● (E)CA(E)G(E)DI(E)DIR●●●(E)CA (E)G (E)LW(E)LW(E)LW(E)2" LW (E)4" (E)4" LW (E)5" ST (E)4" (E)2" (E)3" LW (E)EMER. SHOWER (R)LW DN (R)LW DN (E)1/2" (E)1/2" (E)3" LW 1 2 1 1 E300C E331●●●(E)CA(E)DI●●●(E)CA(E)G●●●(E)LW(E)LW(E)LW (E)LW (E)LW (E)LW (E)G(E)CA (E)LW(E)LW(E)4" LW (E)4" LV (E)5" ST EXISTING TO REMAIN 3 2 A C D F 12 13 4 4 3 5 5 5 (E)DIR(E)DI(E)G(E)CA ●●● ●●●(E)G(E)CA●●●(E)3/4" (E)1" (E)1 1/4" (E)2" 1 1 REMOVE CA AND HW PIPING. CAP AT POINT OF DISCONNECT. (E)2" (E)1 1/4" (E)3/4" (E)1" (E)3/4" (E)1 1/2" (E)1" (E)2" LW UP (E)2" LW UP (E)3" LW (E)2" LW DN (E)LW(E)4" (E)4" LW DN (E)2" (E)1" (E)3/4"●●●(E)CA(E)G(E)DIR (E)DI(E)G (E)CA ●●● ●●●●●●(E)CA(E)G(E)2" (E)1 1/4" (E)1" (E)3/4" (E)2" LW DN 6 7 (E)4" LV UP & DN (E)2" LV 1 6(E)LW(E)LV (E)2" These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions3/10/2021 3:38:22 PMC:\Users\cmdoktor\Documents\200278_Corson3rdFloor_P_Central_R20_cmdoktor.rvt20636.00 THK Partial Third Floor Plans - Plumbing Demolition GDD CMD P-101 100% Contsruction Documents Cornell University Corson Hall Third Floor Laboratory & Office Renovation Ithaca, NY March 5, 2021 1/4" = 1'-0"2 Partial Third Floor Plan - Plumbing Demolition DEMOLITION NOTES: 1 DISCONNECT SINK AND REMOVE PIPING BACK TO MAIN AND CAP. 2 REMOVE PIPING DOWN AND ALL PIPING UNDER COUNTER. 3 DISCONNECT FUME HOOD AND REMOVE PIPING BACK TO MAIN AND CAP. 4 REMOVE TURRETS AND PIPING BACK TO MAIN AND CAP. 5 REMOVE CUP SINK AND RELATED PIPING BACK TO MAINS. IF PIPING GOES BELOW FLOOR CAP AS CLOSE TO THE FLOOR AS POSSIBLE BUT DO NOT CAP BELOW FLOOR. 6 REMOVE PIPING AND CAP AT POINT OF DISCONNECT. 7 REMOVE LAB WASTE BUT LEAVE SECTION GOING BELOW FLOOR AND PREP FOR RECONNECTION. 1/4" = 1'-0"1 Partial Third Floor Plan - Plumbing Demolition C D F H 15 16 17 18 OFFICE E321 COMPUTATIONAL LAB E323 Room E325 OPEN LAB E334 ACID WASH E334A VEST E334B SOIL ROOM E318 (E)LW(E)LW(E)LW(E)2" LW (E)4" (E)4" LW (E)5" ST(E)3" LW (E)EMER. SHOWER (E)3" LW (x4) 1/2" CW, HW & DI DN. 3/4" G & CA DN. ROUTE UNDER LAB BENCH. CUT AND PATCH WALL AS REQUIRED. E300C E331(E)DIR(E)DI(E)G(E)CA ●●● ●●●●●●CA GDI ●●● ●●● (E)CA(E)G(E)DI(E)DIR●●●(E)CA (E)G SK-G SK-D SK-F SK-D 2" LW DN TO SECOND FLOOR 1/2" CW & HW DN. 2" LW DN TO SECOND FLOOR. ROUTE UNDER LAB BENCH TO SINK. CUT AND PATCH WALL AS REQUIRED. PROVIDE SEDIMENT TRAP ON DRAIN.GCA1/2" 1/2" ●●● 1/2"1/2" 1/2"DI● (E)2" LW UP 4" (E)2" LW UP (E)4" LW (E)4" LV (E)5" ST 1/2"G & CA DN TO GO-A & CA-A IN COUNTER. SET LOCATIONS TO MEET ADA. 1/2" G & CA DN TO IN COUNTER. CUT AND PATCH WALL AS REQUIRED. 1/2" G & CA TO EACH TURRET. REFER TO ARCHITECTURAL PLANS FOR LOCATIONS. EW-A EW-A EW-A 2" LW DN. REFER TO DETAIL 4 ON P-000. 1/2" 1/2" CW & HW DN. 2" LW DN TO SECOND FLOOR. ROUTE UNDER LAB BENCH TO SINK. CUT AND PATCH WALL AS REQUIRED. PROVIDE SEDIMENT TRAP ON DRAIN. E' PROVIDE ULTRA PURE AIR MANIFOLD. REFER TO DETAIL 2 ON P-000. ROUTE 1/4" STAINLESS STEEL TUBING TO EQUIPMENT D' & E' AND PROVIDE AN EXTRA 2'-0" OF TUBING THEN CAP. FINAL CONNECTION BY CU. 1/2" RODI DN EXPOSED TO EPURE UNIT. EPURE UNIT TO BE FURNISHED BY CU & INSTALLED BY THIS CONTRACTOR. PROVIDE PURE WATER FROM UNIT THEN RUN IN WALL TO BELOW SINK. CONNECT TO EPURE FAUCET. N2 TANK LOCATION. ROUTE 1/4" STAINLESS STEEL TUBING TO EQUIPMENT K' AND PROVIDE AN EXTRA 2'-0" OF TUBING THEN CAP. FINAL CONNECTION BY CU. PROVIDE H2 MANIFOLD. REFER TO DETAIL 2 ON P-000. ROUTE 1/4" STAINLESS STEEL TUBING TO EQUIPMENT D' AND PROVIDE AN EXTRA 2'-0" OF TUBING THEN CAP. FINAL CONNECTION BY CU. P5 TANK LOCATION ROUTE 1/4" STAINLESS STEEL TUBING TO EQUIPMENT D' AND PROVIDE AN EXTRA 2'-0" OF TUBING THEN CAP. FINAL CONNECTION BY CU. 1/2" CW, HW & DI TO FAUCET. 1/2" G & CA TO EACH TURRET. REFER TO ARCH DRAWINGS FOR LOCATIONS. ROUTE UNDER BENCH. 2" LW DN TO SECOND FLOOR D' 1/2" CW & CA DN TO FUME HOOD 1/2" ACETYLENE TANK LOCATION. SK-E 1 1 1(E)DI(E)CA●●●GO-A GO-A GO-B K' CA-B CA-A CA-A GO-A CA-A PROVIDE PIPING CONNECTION TO EXISTING PIPING. (TYP=4) PROVIDE 1/4" STAINLESS STEEL TUBING FROM EQUIPMENT K' TO D'. FINAL CONNECTION BY CU. 3/4" G DN EXPOSED TO BALL VALVE AT 5'-6" AFF WITH SIGNAGE "GAS SHUT OFF". REFER TO DETAIL 5 ON P-000.G3/4"(E)G3/4" A C D F 12 13 (E)DIR(E)DI(E)G(E)CA ●●● ●●●(E)G(E)CA●●●(E)3/4" (E)1" (E)1 1/4" (E)2" (E)2" LW UP (E)2" LW UP (E)3" LW(E)LW(E)4" LW DN (E)2" (E)1" (E)3/4"●●●(E)CA(E)G(E)DIR (E)DI(E)G (E)CA ●●● ●●●●●●(E)CA(E)G(E)2" (E)1 1/4" (E)1" (E)3/4" 3/4" CA DN TO CA-A 1/2"●●●DI 2"1 1/4" (E)4"(E)LW(E)4"DIDIR1/2" 1/2" CW & HW DN TO SK-C 1/2" CA & 1/2" G DN TO GO-A & CA-A SK-A SK-B SK-C SK-A 2" LW 2" LW 2" LW DN G ●CA 2" LW, 1/2" CW, 1/2" G & 1/2" CA DN IN WALL. ROUTE IN CASEWORK CHASE TO FUME HOOD. LAB E304 Room E304A Room E306 DARK ROOM E304B FACULTY OFFICE E303 LAB E305 Room E309 Room E309A 1/2" DI DN TO SK-A, SK-B & SK-C CA G K G H EW-A G LW 1/2" CW, HW & RODI WATER IN CASEWORK PROVIDE H2 MANIFOLD. REFER TO DETAIL 2 ON P-000. ROUTE 1/4" STAINLESS STEEL TUBING TO EQUIPMENT H AND PROVIDE AN EXTRA 2'-0" OF TUBING THEN CAP. FINAL CONNECTION BY CU. 1 PROVIDE ULTRA PURE AIR MANIFOLD. REFER TO DETAIL 2 ON P-000. ROUTE 1/4" STAINLESS STEEL TUBING TO EQUIPMENT G, H & K. HE TANK LOCATION ROUTE 1/4" STAINLESS STEEL TUBING TO EQUIPMENT H AND PROVIDE AN EXTRA 2'-0" OF TUBING THEN CAP. FINAL CONNECTION BY CU. P5 TANK LOCATION ROUTE 1/4" STAINLESS STEEL TUBING TO EQUIPMENT H AND PROVIDE AN EXTRA 2'-0" OF TUBING THEN CAP. FINAL CONNECTION BY CU. EW-A1 2" LW (E)2" LW DN 1 1/2" LV UP (E)4" LV UP 2" LV UP AS HIGH AS POSSIBLE IN CHASE. CUT AND PATCH WALL AS REQUIRED. CONNECT TO (E)4" LV CONNECT TO (E)2" LW 3/4" G DN EXPOSED TO BALL VALVE AT 5'-6" AFF WITH SIGNAGE "GAS SHUT OFF". REFER TO DETAIL 5 ON P-000. (E)LV 2" (E)4" LV UP & DN 1/2" CA & 1/2" G DN TO GO-A & CA-A FUTURE H2 TANK GENERAL NOTES: A. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF NATURAL GAS AND COMPRESSED AIR OUTLETS. These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions3/15/2021 1:31:46 PMC:\Users\cmdoktor\Documents\200278_Corson3rdFloor_P_Central_R20_cmdoktor.rvt20636.00 THK Partial Third Floor Plans - Plumbing GDD CMD P-201 100% Contsruction Documents Cornell University Corson Hall Third Floor Laboratory & Office Renovation Ithaca, NY March 5, 2021 1/4" = 1'-0"2 Partial Third Floor Plan - Plumbing 1/4" = 1'-0"1 Partial Third Floor Plan - Plumbing DRAWING NOTES: 1 REFER TO DETAIL 3 ON P-000. UPRIGHT SPRINKLER DESCRIPTIONSYMBOL FIRE PROTECTION SYMBOL LIST QUICK RESPONSE UPRIGHT SPRINKLER POINT OF CONNECTION SIDEWALL SPRINKLER NTS NOT TO SCALE (ETR)EXISTING TO REMAIN GC GENERAL CONTRACTOR PC PLUMBING CONTRACTOR FC FLUSHING CONNECTION NEW PIPING S SPRINKLER MAIN/BRANCH PIPING (S) ELBOW DOWN DRAIN VALVE ELBOW UP CHECK VALVE TOP TEE CONNECTION PRESSURE REDUCING VALVE FLUSHING CONNECTION RELIEF VALVE DRY PENDENT SPRINKLER BACKFLOW PREVENTER (BFP) SHUT-OFF VALVE WITH TAMPER SWITCH (TS) EXISTING WORK TO BE REMOVED AFF ABOVE FINISHED FLOOR MC MECHANICAL CONTRACTOR EC ELECTRICAL CONTRACTOR (E)EXISTING PIPING FP FIRE PROTECTION SERVICE (FP) D SPRINKLER DRAIN PIPING (D) 45°OFFSET BOTTOM/TEE CONNECTION PIPE CONTINUATION PENDENT SPRINKLER QUICK RESPONSE PENDENT SPRINKLER POINT OF DISCONNECTION FS FLOW SWITCH (FS) DRY PRE-ACTION ALARM VALVE ALARM CHECK VALVE WITH TRIM (ACV) FIRE DEPARTMENT VALVE (FDV) INSPECTOR'S TEST CONNECTION (ITC) (E)EXISTING OR DRAWING KEYNOTE DEMOLITION/REMOVAL KEYNOTE X X X X STANDPIPE CALLOUT SPRINKLER BRANCH LINE IF OFFSET LENGTH EXCEEDS 2', PROVIDE PIPE HANGER DROP NIPPLE CLOSE NIPPLE REDUCER SUSPENDED CEILING SPRINKLER PER SPEC (RECESSED PENDENT SPRINKLER SHOWN) (PENEDENT WITH GUARD) THREADED 90° ELBOW (TYPICAL) REDUCER SUSPENDED CEILING SPRINKLER PER SPECIFICATION (PENDENT SPRINKLER WITH GUARD SHOWN) DETAIL NOTES: DOMESTIC COLD WATER FLOW DIRECTION LABEL. PROVIDE 360 DEGREE WRAP OVERLAPPING BOTH ENDS OF THE PIPE FUNCTION LABEL AND MATCHING THE FLOW DIRECTION OF THE PIPE CONTENTS. PIPE FUNCTION LABEL A. B. C. D. E. F. PROVIDE A PIPE LABEL FOR EACH PIPE FUNCTION. PROVIDE AT LEAST ONE LABEL ON EACH PIPE FOR EVERY ROOM THE PIPE PASSES THROUGH. PROVIDE LABELS IN LARGE SPACES ON MAXIMUM 20' CENTERS FOR EVERY PIPE UNLESS OTHERWISE NOTED IN THE SPECIFICATIONS. LABELS TO BE LOCATED IN AN EASILY VISIBLE LOCATION AS THEY WOULD NORMALLY BE SEEN. IE. ON THE BOTTOM HALF OF PIPES IN THE AIR AND ON THE TOP HALF OR SIDES OF PIPES MOUNTED LOW. LABELS SHALL BE, COLOR CODED, PRE-PRINTED, SELF ADHESIVE VINYL. SEE SPECIFICATION FOR OTHER REQUIREMENTS AND LIST OF PIPE FUNCTIONS. These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions3/10/2021 3:38:19 PMC:\Users\cmdoktor\Documents\200278_Corson3rdFloor_P_Central_R20_cmdoktor.rvt20636.00 THK General Notes And Symbols List GDD CMD FP-000 100% Contsruction Documents Cornell University Corson Hall Third Floor Laboratory & Office Renovation Ithaca, NY March 5, 2021 EXISTING CONDITIONS ARE TAKEN FROM FIELD OBSERVATIONS AND PRIOR CONSTRUCTION DOCUMENTS WHEN AVAILABLE. THE LOCATIONS SHOWN MUST BE CONSIDERED APPROXIMATE. OTHER SUCH WORK MAY EXIST, HOWEVER, LOCATION AND SIZE ARE NOT PRESENTLY KNOWN. VISIT SITE PRIOR TO BID TO REVIEW EXISTING CONDITIONS AND DETERMINE SCOPE OF WORK. WHEN EXISTING CONSTRUCTION IS DAMAGED DURING WORK BY THIS CONTRACTOR, REPAIR AND/OR REPLACE WITH SIMILAR OR LIKE MATERIALS AS MUCH AS POSSIBLE, SUBJECT TO ARCHITECTS APPROVAL. DISPOSE OF ALL DEMOLITION AND/OR OTHER WASTE MATERIALS CAUSED BY WORK OF THIS CONTRACTOR. LEGALLY DISPOSE ALL MATERIALS TO A LOCATION OFF SITE. COORDINATE AND SCHEDULE WORK AND SHUTDOWNS WITH THE OWNER AND OTHER TRADES PRIOR TO DEMOLITION. ALL EXISTING PIPING TO REMAIN SHALL BE RECONNECTED TO ACTIVE SERVICE PIPING. ALL PIPING TO BE REMOVED, SHALL BE REMOVED BACK TO ACTIVE PIPING AND CAPPED. VALVE AND CAP ALL WATER PIPING. REMOVE ALL INACTIVE PIPING UNLESS NOTED. ALL PIPING TO BE REMOVED AND LOCATED WITHIN A WALL TO REMAIN MAY BE ABANDONED IN PLACE UNLESS NOTED. REMOVE PIPING BACK TO BEHIND THE FINISHED WALL SURFACE AND CAP. PLUG HOLES IN EXISTING CONSTRUCTION LEFT BY THE REMOVAL OF PIPING OR EQUIPMENT. MAINTAIN FIRE/SMOKE RATING. DEMOLITION SHALL INCLUDE, BUT NOT BE LIMITED TO: PIPING, VALVES, FIXTURES, EQUIPMENT, HANGERS, SUPPORTS, AND INSULATION EXCEPT ASBESTOS. All SECURING AND ATTACHMENT POINTS TO EXISTING BUILDING STRUCTURE INCLUDING WALLS, CEILINGS, FLOORS, SLABS, DECKS, ETC. SHALL BE REVIEWED WITH CORNELL UNIVERSITY AND THE PROJECT ENVIRONMENTAL CONSULTANT PRIOR TO SECURING AND ATTACHING DEVICES AND EQUIPMENT. SOME BUILDING ELEMENTS MAY CONTAIN ASBESTOS AND ABATEMENT MAY BE REQUIRED. ABATEMENT SHALL BE PERFORMED BY SEPARATE CONTRACTOR WITH THE ASSISTANCE OF THIS CONTRACTOR FOR IDENTIFYING ATTACHMENT POINT LOCATIONS. MIXING OF DEMOLITION AND CONSTRUCTION DEBRIS IN COMMON DUMPSTERS IS NOT ALLOWED. ALL DEMOLITION AND CONSTRUCTION DEBRIS SHALL BE SEPARATED AND SORTED THEN PLACED IN THE DESIGNATED DUMPSTER FOR THAT SPECIFIC MATERIAL IN COMPLIANCE WITH PROJECT LEED CONSTRUCTION WASTE MANAGEMENT REQUIREMENTS. ABANDONING EXISTING SYSTEMS, EQUIPMENT AND APPURTENANCES IN PLACE IS NOT ALLOWED. ALL SYSTEMS, EQUIPMENT AND APPURTENANCES DEEMED FOR REMOVAL SHALL BE REMOVED. THE CONTRACTOR SHALL NOTIFY CORNELL UNIVERSITY IF EXISTING SYSTEMS, EQUIPMENT AND APPURTENANCES ARE FOUND THAT HAD NOT BEEN INDICATED ON THE PROJECT PLANS TO EITHER BE REMOVED OR TO REMAIN IN PLACE. PIPE ROUTING DOES NOT SHOW PIPE FITTINGS THAT WILL BE REQUIRED. MOST LOCATIONS WILL REQUIRE PIPING TO RISE INTO STRUCTURAL CAVITY AND THEN BACK DOWN. (TYPICAL ALL LOCATIONS). PROVIDE WIRE GAGES ON ALL SPRINKLERS IN ELECTRICAL AND TR ROOMS. NO WORK TO BE DONE ON FIRE PROTECTION SYSTEM UNTIL HEAT DETECTORS ARE INSTALLED & OPERATIONAL. REFER TO ELECTRICAL DRAWINGS. A. B. C. D. E. F. G. H. I. J. K. L. M. N. O. GENERAL NOTES: NOT TO SCALE 2 RETURN BEND DETAIL NOT TO SCALE 1 PIPING IDENTIFICATION LABEL DETAIL FSE344C E300SB E300C A300UG E301 E310 E340 E344A E344 E344B E320 E309B DN UPFSA C D F 12 13 14 15 16 17 (E)1 1/4" (E)1 1/4" (E)1 1/4" (E)1 1/4"(E)FP(E)FP(E)FP(E)1 1/4"(E)1 1/4"(E)FP(E)FP(E)1" (E)1" (E)1" (E)1"(E)1" (E)1" (E)1" (E)1" (E)1"(E)1" (E)1" (E)ACCESS PANEL (E)6" (E)3" (E)6" FP UP/DN 1 1 1 1 1 1 1 1 (E)SHUTOFF VALVE EXISTING TO REMAIN (TYP OF OFFICES & CORRIDOR) (E)3"(E)FP(E)FP(E)FP(E)FP(E)FP (E)FP(E)FP (E)FP(E)FP(E)FP(E)1 1/4" (E)1 1/4" (E)1 1/4" (E)3" (E)1" (E)1" (E)1" (E)1" (E)1" (E)1"(E)1" (E)1"(E)1" (E)1" (E)1" (E)1" (E)1" (E)1" (E)1" 1 1 1 1 1 1 1 1 EXISTING TO REMAIN (TYP OF OFFICES & CORRIDOR) A C D F 12 13 14 15 16 17 FACULTY OFFICE E303 LAB E305 LAB E304 DARK ROOM E304B Room E304A Room E306 OFFICE E321 COMPUTATIONAL LAB E323 Room E325 OPEN LAB E334 ACID WASH E334A VEST E334B SOIL ROOM E318 Room E309A Room E309 OFFICE 311 KITCHENETTE 317C CONFERENCE 317B OPEN OFFICE 317 FACULTY OFFICE 317A FACULTY OFFICE 315 (E)ACCESS PANEL (E)6" FP UP/DN (E)6" (E)3" (E)1 1/4" (E)1 1/4" (E)1 1/4" (E)1 1/4"(E)FP(E)FP(E)FP(E)1 1/4" (E)1 1/4"(E)FP(E)FP(E)1" (E)1" (E)1" (E)1" (E)1" (E)1" (E)1" (E)1" (E)1" (E)1" (E)1" 1" 1 1 1 1 1 1 1 1 1 (E)SPRINKLER HEAD TO REMAIN (TYP) PROVIDE CORROSION RESISTANT SPRINKLER HEAD (E)SHUTOFF VALVE (E)SPRINKLER HEAD TO REMAIN (TYP) 1 (E)FP (E)FP(E)FP(E)FP(E)1 1/4" (E)1 1/4" (E)1 1/4" (E)3" (E)1" (E)1" (E)1" (E)1" (E)1" (E)1"(E)1" (E)1"(E)1" (E)1" (E)1" (E)1" (E)1" (E)1" 1 1 1 1 1 1 1 (E)SPRINKLER HEAD TO REMAIN (TYP) These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions3/10/2021 3:38:21 PMC:\Users\cmdoktor\Documents\200278_Corson3rdFloor_P_Central_R20_cmdoktor.rvt20636.00 THK Partial Third Floor Plans- Fire Protection GDD CMD FP-100 100% Contsruction Documents Cornell University Corson Hall Third Floor Laboratory & Office Renovation Ithaca, NY March 5, 2021 1/8" = 1'-0"1 Partial Third Floor Plan - Fire Protection Demolition DEMOLITION NOTES: 1 REMOVE HEAD AND MODIFY PIPING AS REQUIRED FOR UPDATED LAYOUT. 1/8" = 1'-0"2 Partial Third Floor Plan - Fire Protection DRAWING NOTES: 1 MODIFY PIPING AS REQUIRED AND CENTER HEADS IN TILES. GENERAL NOTES: A. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DISPOSE OF ALL DEMOLITION DEBRIS AND MATERIALS OFF SITE IN A PROPER LEGAL MANNER. B. ALL NEW PENETRATIONS THROUGH WALLS, FLOORS AND ROOFS SHALL BE PROVIDED FOR INSTALLATION OF MECHANICAL SYSTEMS INCLUDING, BUT NOT LIMITED TO, EQUIPMENT, DUCTWORK, PIPING, ETC. ALL PENETRATIONS THROUGH RATED WALLS AND FLOORS SHALL BE FIRE/SMOKE STOPPED. ALL PENETRATIONS THROUGH NON RATED WALLS SHALL BE SEALED WITH A NON-HARDENING SEALANT ON BOTH SIDES OF WALL PENETRATION TO REDUCE NOISE TRANSMISSION. C. THE DUCTWORK SIZES AND TYPES (ROUND, RECTANGULAR AND FLAT OVAL)WERE SELECTED FOR SPACE LIMITATION WITHIN THE RENOVATED AREA. IN ADDITION, THE DUCTWORK SIZES AND TYPES WERE CHOSEN TO ALLOW SPACE ABOVE THE CEILINGS FOR FUTURE DUCTWORK, PIPING AND/OR CONDUIT. IT IS NOT ACCEPTABLE FOR THE CONTRACTOR TO CHANGE THE SIZE OR TYPE OF DUCTWORK FOR BIDDING OR INSTALLATION UNLESS SPECIFICALLY APPROVED BY THE ENGINEER. D. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE ALL SHUTDOWNS OF AIR HANDLING, CHILLED WATER, HOT WATER, STEAM, ETC. SYSTEMS WITH CORNELL UNIVERSITY FACILITY PERSONNEL FOR TIE-IN CONNECTIONS. ALL SHUT DOWNS WILL OCCUR DURING NIGHTS OR WEEKENDS. THE CONTRACTOR SHALL ASSIST THE UNIVERSITY PERSONNEL IN SHUTTING DOWN, DRAINING, VENTING, ETC. OF SYSTEM TO FACILITATE THE INTENDED WORK. E. A MINIMUM OF 1'-6" SHALL BE PROVIDED IN FRONT OF CONTROL ACCESS ENCLOSURES AT ALL TERMINAL UNITS. NO PIPING OR CONDUIT SHALL BE DIRECTLY INSTALLED BELOW AIR TERMINAL UNIT ACCESS ENCLOSURES THAT WILL PROHIBIT ACCESS UP TO THE CONTROL ENCLOSURE. COORDINATE THESE REQUIREMENTS WITH ALL OTHER TRADES ON THE PROJECT. IF PROPER SERVICE ACCESS IS NOT MAINTAINED BECAUSE OF POOR COORDINATION, THE CONTRACTOR SHALL RELOCATE OBSTRUCTIONS AT NO ADDITIONAL COST TO THE OWNER. F. PROVIDE A VOLUME DAMPER AT EACH DIFFUSER AND GRILLE FOR PROPER BALANCING REGARDLESS IF SHOWN ON DRAWINGS. ALL VOLUME DAMPERS SHALL BE A MINIMUM OF 6'-0" FROM DIFFUSER OR GRILLE CONNECTION. IF FLEXIBLE DUCTWORK IS UTILIZED FOR FINAL CONNECTION AT GRILLES, THE CROSS SECTIONAL AREA OF THE FLEXIBLE DUCTWORK SHALL NOT BE LESS THAN THE CROSS SECTIONAL AREA OF THE GRILLE NECK. G. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE THE LOCATIONS OF ALL ROOM TEMPERATURE SENSORS WITH THE ARCHITECT/ENGINEER. THE CONTRACTOR SHALL SCHEDULE A WALK THROUGH WITH THE ARCHITECT/ENGINEER TO LOCATE SENSOR LOCATIONS PRIOR TO INSTALLATION. THE TEMPERATURE SENSORS SHALL BE INSTALLED IN ALIGNMENT WITH ELECTRICAL, FIRE, AND OTHER DEVICES WHEN LOCATED ON COMMON WALLS. H. DAMAGE TO EXISTING SYSTEMS (EQUIPMENT, PIPING, DUCTWORK, CONTROLS AND ACCESSORIES) SHOWN TO REMAIN AS A RESULT OF THE CONTRACTORS WORK IS THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR AND/OR REPLACE WITH SIMILAR OR LIKE MATERIALS AT NO ADDITIONAL COST TO THE OWNER. I. COORDINATE ALL SHUT DOWNS WITH OWNER PRIOR TO CONSTRUCTION. J. THE DEMOLITION DRAWINGS SHOW IN GENERAL MAJOR EQUIPMENT, PIPING AND DUCTWORK REMOVALS. THE INTENT IS NOT TO IDENTIFY ALL MISCELLANEOUS PIPING, PIPING ACCESSORIES, DUCTWORK, DUCTWORK ACCESSORIES, SUPPORTS, CONTROLS, CONTROL ACCESSORIES, CONTROL WIRING, CONDUIT, AND CONTROL PNEUMATIC TUBING AND ACCESSORIES TO BE DISCONNECTED AND REMOVED BUT IS THE REQUIREMENTS UNDER THIS CONTRACT. NO EQUIPMENT, PIPING OR DUCTWORK SHALL BE ABANDONED IN PLACE UNLESS OTHERWISE NOTED ON THE DRAWINGS. K. THE MOUNTING HEIGHT FOR ALL ROOM THERMOSTATS OR SENSORS SHALL BE 48 IN. TO TOP OF THE COVER. L. UNLESS SHOWN ON THE ARCHITECTURAL DRAWINGS, IT IS THE RESPONSIBILITY OF THIS CONTRACT TO PATCH WITH LIKE MATERIAL AND FINISH ALL EXISTING DUCTWORK OR PIPE PENETRATIONS THROUGH FLOORS AND WALLS AFTER DEMOLITION. M. EXISTING CONDITIONS ARE TAKEN FROM FIELD OBSERVATIONS AND PRIOR CONSTRUCTION DOCUMENTS AND ARE NOT GUARANTEED. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BID. NO ALLOWANCE WILL BE MADE FOR ADDITIONAL COSTS DUE TO CONTRACTORS FAILURE TO VERIFY EXISTING CONDITIONS AND DIMENSIONS. N. THE OWNER OCCUPIED AREAS INCLUDE SENSITIVE EQUIPMENT AND RESEARCH WHICH MUST NOT BE INTERRUPTED OR OTHERWISE DISTRUPTED WITHOUT PRIOR NOTICE AND APPROPRIATE PLANNING. DSD MBH THOUSAND BTU/HOUR (E)EXISTING DOUBLE LINE RECTANGULAR DUCT CONTINUED FPM FEET PER MINUTE AIR FLOW AFF ABOVE FINISHED FLOOR PIPE ANCHOR G.C.GENERAL CONTRACTOR PIPE GUIDE E.C. ELECTRICAL CONTRACTOR EXPANSION COMPENSATOR WITH GUIDES N.C. NORMALLY CLOSED PRE-FAB EXPANSION LOOP TEMPERATURE SENSOR STRAINER PRESSURE GAUGE THERMOMETER UNION 24x12DN UP AIR VENTV24x1214x8 6" BOOT TAP TT THERMOSTATIC TRAP 14"18"LATERAL FT FLOAT & THERMOSTATIC TRAP SUPPLY DIFFUSER, REGISTER OR GRILLE TD THERMODYNAMIC TRAP FLEXIBLE DUCTWORK BT BUCKET TRAP COMPRESSED AIRA DIRECTION OF FLOW BBD BOILER BLOW DOWN CONDENSER WATER SUPPLYCS CR CONDENSER WATER RETURN CWS CHILLED WATER SUPPLY CWR CHILLED WATER RETURN D DRAIN FUEL OIL FILLFOF FUEL OIL GAUGEFOG FOS FUEL OIL SUPPLY FOR FUEL OIL RETURN FOV FUEL OIL TANK VENT G GAS GLYCOL SUPPLYGS GLYCOL RETURNGR HPWS HEAT PUMP WATER SUPPLY HPWR HEAT PUMP WATER RETURN HWS HOT WATER SUPPLY HWR HOT WATER RETURN HG HOT GAS LPS LOW PRESSURE STEAM LPC LOW PRESSURE CONDENSATE MPS MEDIUM PRESSURE STEAM MPC MEDIUM PRESSURE CONDENSATE HPS HIGH PRESSURE STEAM HPC HIGH PRESSURE CONDENSATE PC PUMPED CONDENSATE RD REFRIGERANT DISCHARGE RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION VAC VACUUM CW DOMESTIC COLD WATER EXISTING WORK TO BE REMOVED DOUBLE LINE PIPE OR ROUND DUCT CONTINUED E PNEUMATIC THERMOSTAT NTS NOT TO SCALE (DBL) DOUBLE WALL LINED DUCT CFM CUBIC FEET PER MINUTE AD ACCESS DOOR P.C. PLUMBING CONTRACTOR N.O. NORMALLY OPEN DUCT SMOKE DETECTOR HUMIDISTAT ROUND DUCT - IN INCHES12" 24x12DN UP 14" CONICAL TEE18"VOLUME DAMPER CAP OR PLUG ELBOW DOWN ELBOW UP AAD AUTOMATIC AIR DAMPER FD FIRE DAMPER SD SMOKE DAMPER BDD BACK DRAFT DAMPER M MOTORIZED DAMPER BALL VALVE GATE VALVE CHECK VALVE BALANCING VALVE BUTTERFLY VALVE PRESSURE REDUCING VALVEPRV CONTROL VALVE PRESSURE/TEMPERATURE TEST PLUG (L) (2L) ACOUSTIC THERMAL LINING - 2" THICK M.C. MECHANICAL CONTRACTOR W/W WALL TO WALL G THERMOSTAT/SENSOR WITH GUARDG DUCT SECTION - SUPPLY DUCT SECTION - RETURN WIDTH A x DEPTH BA B R D 24x1214" 6" BOOT TAP BG BLAST GATE FIN TUBE RADIATION VALANCE A B C REGISTER, GRILLE OR DIFFUSER TAG A = TYPE B = NECK SIZE C = CFM B C D FIN TUBE RADIATION TAG FT-A = TYPE B = FIN TUBE LENGTH C = ENCLOSURE LENGTH D = GPM FT-A A B C D VALANCE TAG A = TYPE B = COIL SIZE C = COOLING GPM D = HEATING GPM POINT OF CONNECTION POINT OF DISCONNECTION BOTTOM TAP TRIPLE DUTY VALVETD GLOBE VALVE THREE WAY CONTROL VALVE SUCTION DIFFUSERSD DRAIN VALVE WITH HOSE CONNECTION, CAP AND CHAIN FC FLEX CONNECTOR - DUCTWORK FLEXIBLE CONNECTOR - PIPING AIR TERMINAL UNIT AND TAG (OPTION 1) A B C AIR TERMINAL UNIT TAG (OPTION 2) A = UNIT NO. B = MAXIMUM CFM C = MINIMUM CFM AxB FO DUCT SECTION - FLAT OVAL (FO) V VENT REDUCER S H S ACOUSTIC THERMAL LINING - 1-1/2" THICK EXHAUST GRILLE RETURN REGISTER SINGLE LINE PIPE CONTINUED TRANSITION SQUARE TO ROUND RISE IN DUCT - IN DIRECTION OF AIRFLOW DROP IN DUCT - IN DIRECTION OF AIRFLOW SUPPLY DUCT TURNING UP OR DOWN RETURN DUCT TURNING UP OR DOWN SUPPLY/RETURN RECTANGULAR MAIN RECTANGULAR BRANCH SUPPLY/RETURN RECTANGULAR MAIN ROUND BRANCH SUPPLY/RETURN ROUND MAIN ROUND BRANCH SUPPLY/RETURN ROUND MAIN ROUND BRANCH MITERED ELBOW WITH TURNING VANES DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL T RELIEF VALVE T HVAC SYMBOL LIST X X DRAWING KEYNOTE DEMOLITION KEYNOTE A B C RADIANT CEILING PANEL TAG A = TYPE B = LENGTH C = GPM CARBON DIOXIDE SENSORC CARBON MONOXIDE SENSORCO GAS SENSORG SYMBOL DESCRIPTION SYMBOL DESCRIPTION AVERAGING SENSOR SS START/STOP OC OPEN/CLOSE ED ENABLE/DISABLE T TEMPERATURE SENSOR (DUCT OR PIPE MOUNTED) H HUMIDITY SENSOR (DUCT MOUNTED) IP ELECTRICAL INTERFACE AUTOMATIC AIR DAMPER (PARALLEL BLADE) AUTOMATIC AIR DAMPER (OPPOSED BLADE) E ELECTRIC/ELECTRONIC CONTROL VALVE (3-WAY) E ES END SWITCH EA EXHAUST AIR MOISTURE SENSOR OCCUPANCY SENSOR FLOW METER SUPPLY FANSF BTU ENERGY METERBTU P DIFFERENTIAL STATIC PRESSURE SWITCH ALARM STATUS PROBE SENSOR RELAY FREEZE-STATFZ E ELECTRIC ACTUATOR CURRENT TRANSDUCER FLOW SENSOR AIR FLOW MEASURING STATION HARD WIRE INTERFACE S SOLENOID VALVE S M MANUAL SWITCH THERMOSTATIC EXPANSION VALVE CARBON DIOXIDE SENSOR (DUCT MOUNTED) CO 2 BINARY POINT ANALOG POINT THERMOWELL P DIFFERENTIAL STATIC PRESSURE TRANSMITTER ASD ADJUSTABLE SPEED DRIVE R134a REFRIGERANT R134a SENSOR (WALL MOUNTED) C C COOLING COIL BASE MOUNTED PUMP FILTER BANK RETURN AIR FANRF EF EXHAUST AIR FAN H C HEATING COIL SMOKE CONTROL FANSC HUMIDIFIER DISPERSION GRID EP ELECTRIC/PNEUMATIC SWITCH OR RELAY PE PNEUMATIC/ELECTRIC SWITCH OR RELAY F FLOW TRANSMITTER P PRESSURE TRANSMITTER ELECTRIC/PNEUMATIC TRANSDUCER IE ELECTRONIC/ELECTRIC TRANSDUCER PNEUMATIC CONTROL VALVE (3-WAY) PNEUMATIC CONTROL VALVE (2-WAY) ELECTRIC/ELECTRONIC CONTROL VALVE (2-WAY) PNEUMATIC ACTUATOR MAIN TEMPERATURE CONTROL AIR SOURCEA IN LINE PUMP HR C HEAT RECOVERY COIL AIR TERMINAL UNIT WITH FACTORY ATTENUATOR (OPTION 1) VAV-X-XX VAV-X-XX LAB AIR VALVE RADIANT CEILING PANEL FLOW SWITCH VARIABLE FREQUENCY DRIVE G B GAS BURNER P PRESSURE SWITCH HUMIDIFIERH A R S OS M FS F BUTTERFLY CONTROL DAMPER VFD OA OUTSIDE AIR RA RETURN AIR SA SUPPLY AIR CARBON MONOXIDE SENSOR (DUCT MOUNTED) CO F.L. FAIL LAST DEWPOINT SENSOR (DUCT MOUNTED) DP C CONDENSATE SENSOR STATIC PRESSURE SENSOR (DUCT MOUNTED) SP CT BI BINARY INPUT BO BINARY OUTPUT AI ANALOG INPUT AO ANALOG OUTPUT BV BINARY VALUE AV ANALOG VALUE HIGH LEVEL SWITCHHI LOW LOW LEVEL SWITCH VENTURI AIRFLOW CONTROL VALVE TRANSFORMER MOTOR STARTERMS ROTATION DETECTORRD SMOKE DETECTORSD MOD MODULATING ELECTRIC TO PNEUMATIC TRANSDUCEREP SPEED COMMANDSC AOM ADDRESSABLE OUTPUT MODULE (FIRE ALARM INTERFACE) COM NETWORK COMMUNICATION INTERFACE POINT SIGNAL OUT CURRENT SENSORCS SIGNAL OUT A SIGNAL IN AIR IN A SIGNAL IN ELECTRIC TO PNEUMATIC SWITCH LINE VOLTAGE THERMOSTAT T NITROGEN DIOXIDE SENSORN MOTOR S SPACE SENSOR WITH SETPOINT ADJUSTMENT SA S SPACE SENSOR WITH OCCUPANCY OVERRIDE S SPACE SENSOR WITH VISUAL DISPLAY S SPACE SENSOR WITH FAN ON/OFF SWITCH T ROOM TEMPERATURE SENSOR WITH SETPOINT ADJUSTMENT T T T ROOM TEMPERATURE SENSOR WITH OCCUPANCY OVERRIDE ROOM TEMPERATURE SENSOR WITH VISUAL DISPLAY ROOM TEMPERATURE SENSOR WITH FAN ON/OFF SWITCH BINARY INPUT (GENERAL)BI BO BINARY OUTPUT (GENERAL) ANALOG INPUT (GENERAL) ANALOG OUTPUT (GENERAL) AI AO LIQUID IMMERSION TEMPERATURE SENSOR T SINGLE POINT SENSOR M M OV D F SA OV D F F.O. FAIL OPEN RELATIVE HUMIDITY SENSORRH LOW LIMIT TEMPERATURE SWITCH FZ CONTROLS SCHEMATIC SYMBOL LIST These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions3/10/2021 4:10:03 PMC:\Users\sjgottlieb\Documents\200278_Corson3rdFloor_M_Central_R20_sjgottlieb.rvt20636.00 NMJ General Notes and Symbols List - HVAC GDD SJG M-000 100% Construction Documents Cornell University Corson Hall Third Floor Laboratory & Office Renovation Ithaca, NY March 5, 2021 DN DN UP DN DN UP A C D F H 11 12 13 14 15 16 17 18 E304 E304B E305E303 E318A E318 (E)36x16(E)36x18 (E)26x16 (E)14x12(E)20x16 (E)18x12(E)14x12 (E)22x12(E)26x12(E)36x16 (E)18x10 (E)34x16(E)34x18 (E)20x12 (E)20x12 (E)16x10 (E)16x10 (E)7" (E)10x6 (E)8" (E)8" (E)10x6 (E)10" (E)12x12 (E)8" (E)10" (E)8" (E)4" (E)6"(E)18x10 (E)7"(E)18x10 (E)18x10 (E)10" (E)10" (E)18x10 (E)18x10 (E)12x12 (E)16x10 (E)3" (E)12x8 (E)3/4" (E)2"(E)VAV(E)VAV(E)VAV (E)VAV (E)RADIATION (E)VAVD R (E)2" (E)VAV (E)CWR (E)CWS T T TT (E)12" T (E)12x10 (E)VAV (E)18x10 D (E)2" (E)10" (E)2 1/2" (E)1 1/2" (E)LPS (E)LPC (E)RADIATION (E)FUME HOOD 1 3 2 3 1 4 8 8 8 8 8 2 1 5 (E)VAV 8 6 Room E331 E344A E344 E310 320 E300SB E300C Room E325 OFFICE 311 FACULTY OFFICE 315 FACULTY OFFICE 317A OPEN OFFICE 317 CONFERENCE 317B KITCHENETTE 317C OFFICE E321 COMPUTATIONAL LAB E323 OPEN LAB E334 E340 (E)12x8 (E)7" (E)10" (E)7" (E)7" (E)18x10(E)16x8 (E)16x8 (E)7" (E)FD (E)72x26 UP & DN (E)30x20 UP & DN (E)28x20 UP & DN (E)42x18 UP & DN (E)42x24 UP & DN (E)48x36 UP & DN (E)FD (E)7" (E)12x8 (E)16x10 (E)16x10 (E)18x10 (E)24x18(E)7"(E)16x8 (E)12x8 (E)7"T (E)FUME HOOD EXHAUST AIR TERMINAL UNIT (E)VAV 8 89 9 9 8 1 1 1 1 1 1 1 1 1 1 5 10 10 3 T 3 (E)CANOPY HOODE306 E304A (E)CANOPY HOOD E344B E344C E309 E309A E309B E301 7 (E)VAV(E)10" (E)10" EA UP 2 9 9 19 1 1 19 9 (E)RADIATION (TYP) (E)FUME HOOD EXHAUST AIR TERMINAL UNIT 9 3 A C D F H 11 12 13 14 15 16 17 18 FACULTY OFFICE E303 LAB E305 LAB E304 DARK ROOM E304B Room E304A Room E306 OPEN LAB E334 ACID WASH E334A VEST E334B SOIL ROOM E318 Room E309A Room E309 12x10 10" 10" 10" 8" 12x8 8" 8" 8" " 2 315 10 " 2 315 10 " 3 375 10 " 1 350 10 " 2 125 8 FD/SD 9" EA UP 8" SAV-5 SAV-6 FEV-3 FEV-2 SAV-3 SAV-4 GEV-3 10x8 (E)26x16 (E)14x12(E)20x16 (E)18x12(E)14x12(E)22x12(E)26x12(E)36x16 (E)20x12 (E)7" (E)10x6 (E)10x6 (E)10" (E)12x12 (E)6" (E)18x10 (E)10" (E)10" (E)18x10 (E)12x12 (E)16x10 (E)12x8 (E)VAV(E)VAV (E)RADIATION (E)VAVD (E)CWR (E)CWS T T (E)12" R (E)20x12 S S S 1 1 1 11 9" 4 4EH-2 10" 2 ERHC-6 ERHC-5 12x10 10" 12x8 ERHC-3 ERHC-4 8" (E)RADIATION (E)2 1/2" (E)1 1/2" (E)LPS (E)LPC Room E331 E344A E310 320 E300SB E300C Room E325 OFFICE 311 FACULTY OFFICE 315 FACULTY OFFICE 317A OPEN OFFICE 317 CONFERENCE 317B KITCHENETTE 317C OFFICE E321 COMPUTATIONAL LAB E323 E340 (E)36x16 (E)34x16 E344 E344B E344C E301 (E)36x18 (E)34x18 (E)12x8 (E)7" (E)10" (E)7" (E)7" (E)FD (E)72x26 UP & DN (E)30x20 UP & DN (E)28x20 UP & DN (E)42x18 UP & DN (E)42x24 UP & DN (E)48x36 UP & DN (E)FD (E)7" (E)12x8(E)24x18(E)7" (E)16x8 (E)VAV (E)CANOPY HOOD (E)CANOPY HOOD E309B E301 (E)10"x22 22 A - x22 22 A - 12x10 18x12 12x10 12"(E)VAV8" 10" ERHC-1 SAV-1 10" FEV-1 8"5" SAV-2 ERHC-2 12x10 8" 10" GEV-2 10x6 12x10 x22 22 A 415 " 1 500 10 x10 22 (E) 150 " (E) 150 8 VAV-1 " 1 515 TYP=2 10 5 5 1 1 1 1 6 S SS (E)10" EA UP GEV-1 x22 22 A 500 7 EH-1 3 (E)RADIATION (TYP) D R DSDDSD DSD DSD FD/SDFD/SD FD/SD S D 12"S 9 S 9 10 8x6 x8 6 A 185 8 x6 8 A 140 8" 8x6 GEV-4 8 8x6 DN TO GRILLE 8x6 DN TO GRILLE These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions3/15/2021 1:26:06 PMC:\Users\sjgottlieb\Documents\200278_Corson3rdFloor_M_Central_R20_sjgottlieb.rvt20636.00 NMJ Partial Third Floor Plans - HVAC GDD SJG M-100 100% Construction Documents Cornell University Corson Hall Third Floor Laboratory & Office Renovation Ithaca, NY March 5, 2021 1/8" = 1'-0"1 Partial Third Floor Plan - HVAC - Demolition 1/8" = 1'-0"2 Partial Third Floor Plan - HVAC DEMOLITION NOTES 1 DISCONNECT AND REMOVE EXISTING DUCTWORK AND ACCESSORIES. 2 CAP AND SEAL DUCTWORK AIRTIGHT AT POINT OF DISCONNECT. 3 DISCONNECT AND REMOVE EXISTING THERMOSTAT. REMOVE PNEUMATIC TUBING BACK TO THE SOURCE. 4 DISCONNECT AND REMOVE PIPING AND ACCESSORIES BACK TO THE MAIN. CAP AND SEAL WATER TIGHT. 5 DISCONNECT AND REMOVE EXISTING EXHAUST DUCTWORK AND ACCESSORIES FROM EXISTING FUME HOOD. 6 DISCONNECT AND REMOVE EXISTING DUCTWORK FROM OVEN. 7 DISCONNECT AND REMOVE EXISTING PNEUMATIC CONTROL VALVE. 8 DISCONNECT AND REMOVE EXISTING AIR TERMINAL AND ASSOCIATED CONTROLS. 9 DISCONNECT AND REMOVE EXISTING DIFFUSER/GRILLE. 10 DISCONNECT AND REINSTALL EXISTING DIFFUSER/GRILLE AS REQUIRED TO ACCOMMODATE NEW CEILING. SEE NEW WORK PLANS FOR FURTHER REQUIREMENTS. DRAWING NOTES 1 TIE DUCTWORK INTO EXISTING. PROVIDE ALL DUCTWORK MODIFICATIONS AS REQUIRED TO MAKE THE CONNECTION. 2 TIE DUCTWORK INTO ADJUSTABLE HEIGHT FUME HOOD, REFER TO DETAILS FOR FURTHER REQUIREMENTS. 3 CANOPY EXHAUST HOOD SHALL BE MOUNTED 42 INCHES ABOVE MILLWORK. 4 CORROSIVE EXHAUST DUCTWORK. DUCTWORK SHALL BE PVC CONSTRUCTION. DUCTWORK SHALL BE WRAPPED IN TWO LAYERS OF 1-1/2 INCH FIRE WRAP. REFER TO SPECIFICATIONS FOR FURTHER REQUIREMENTS. 5 NEW LOCATION FOR EXISTING DIFFUSER/GRILLE. 6 PROVIDE NEW CONTROLS AND CONTROL ACCESSORIES FOR THE EXISTING AIR TERMINAL UNIT. REBALANCE EXISTING AIR TERMINAL UNIT. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 7 PROVIDE NEW 2-WAY CONTROL VALVE WITH ELECTRONIC ACTUATION, CONTROLS AND PIPING ACCESSORIES AS REQUIRED TO ACCOMMODATE NEW CONNECTION. 8 LOCATE GRILLE 6" ABOVE FINISHED FLOOR. 9 PROVIDE BREAK GLASS MANUAL SHUTOFF AT LOCATION SHOWN. SWITCH SHALL CONTROL/CLOSE THE AIR VALVES ASSOCIATED WITH THE SPACE. PROVIDE LABEL AT SWITCH WHICH READS "VENTILATION SYSTEM EMERGENCY SHUTOFF". 10 PROVIDE A DIFFERENTIAL PRESSURE SENSOR AT LOCATION SHOWN TO CONTROL THE OPERATION OF LEF-1. UP DN LADDER UP DN UP A C D F H L 12 13 14 15 16 17 18 EXHAUST FAN LEF-1 E4P0SB E4P0U A4P0S ROOF A C D F H 15 16 17 (E)34x16 (E)20x16(E)16x10(E)16x10 (E)12x10 (E)10x12 (E)12x10 (E)10x10 (E)VAV(E)EAV 9" EA UP & DN (E)20x12 21 E440 E400C E412 E412B E416 E419E417E413 E419A E412C E416A These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions3/10/2021 4:10:10 PMC:\Users\sjgottlieb\Documents\200278_Corson3rdFloor_M_Central_R20_sjgottlieb.rvt20636.00 NMJ Partial Fourth Floor and Roof Plans - HVAC GDD SJG M-101 100% Construction Documents Cornell University Corson Hall Third Floor Laboratory & Office Renovation Ithaca, NY March 5, 2021 1/8" = 1'-0"1 Partial Roof Plan - HVAC 1/8" = 1'-0"2 Partial Fourth Floor Plan - HVAC DRAWING NOTES 1 CORROSIVE EXHAUST DUCTWORK. DUCTWORK SHALL BE PVC CONSTRUCTION. DUCTWORK SHALL BE WRAPPED IN TWO LAYERS OF 1-1/2 INCH FIRE WRAP. REFER TO SPECIFICATIONS FOR FURTHER REQUIREMENTS. 2 OFFSET NEW EXHAUST DUCT RISER AROUND EXISTING DUCTWORK AS REQUIRED. NMJ NMJ M-200 P CONTROLLER ANALOG ELECTRIC MOD AO AV SETPOINT AI AI FLOW ALARM SAV SA H C H C AIR SUPPLY BI OS sa d AI T SETPOINT AV REFER TO PLANS AO AO MONITOR HOOD FUME - ALARM - SASH POSITION FEEDBACK - VALVE POSITION COMMAND INTERFACE CARD: EXHAUST VALVE HOOD FUME HOOD MONITOR TO ANALOG POINT FROM EXHAUST FUME HOOD INDICATOR SASH POSITION VERTICAL HOOD INTERFACE CARDCONTROLLER WITHANALOG ELECTRICAO AI AI FLOW ALARM R COMMAND VACANCY UNOCCUPIED OCCUPIED/ AI SASH P HOOD INTERFACE CARDCONTROLLER WITHANALOG ELECTRICAO AI AI FLOW ALARM R COMMAND VACANCY UNOCCUPIED OCCUPIED/ AI SASHFEV - ALARM - SASH POSITION FEEDBACK - VALVE POSITION COMMAND INTERFACE CARD: EXHAUST VALVE HOOD FUME HOOD MONITOR TO ANALOG POINT FROM EA CONTROLLER ANALOG ELECTRIC MOD AO AI AI FLOW ALARM AV SETPOINT 1 FEVSAV FUME HOOD MOTORIZED IAO ZONE CONTROLLER ANALOG ELECTRIC MOD AO AI AI FLOW ALARM AV SETPOINT GEV T AI F AI EXHAUST GENERAL LAB E334 WITH SUPPLY AIR VALVE, FUME HOOD EXHAUST AIR VALVE & GENERAL EXHAUST AIR VALVE CONTROL SCHEMATIC AND SYSTEM SUMMARY NOT TO SCALE POINT SCHEDULE EQUIPMENT HARDWARE POINTS SOFTWARE POINTS GRAPHIC SHOWN ON NOTES BI BO AI AO AV BV SCH TREND ALARM BACS EMCS DESCRIPTION STEAM LOAD SHED X (6)BINARY NETWORK INPUTS FROM EMCS CHILLED WATER LOAD SHED X (4)BINARY NETWORK INPUTS FROM EMCS TOTAL EXHAUST AIRFLOW (CFM)X X X TOTAL EXHAUST SETPOINT (CFM)X X X LAB AIR CHANGE RATE (ACPH)X X X ROOM AREA (SQ FT)X X CEILING HEIGHT (FT)X X FLOW OFFSET SETPOINT (CFM)X X FLOW OFFSET ACTUAL (CFM)X X FUME HOOD EXHAUST AIR VALVE AIRFLOW FEEDBACK (CFM)X X X FUME HOOD EXHAUST AIR VALVE STATUS X `VALVE COMMAND NOT EQUAL TO FEEDBACK X TRI-STATE ALARM X LOW DIFFERENTIAL PRESSURE (VIA SWITCH) FUME HOOD SASH POSITION X X X SASH OPEN (18') FOR 24 CONTINUOUS HOURS OR MORE X FUME HOOD EXHAUST AIR VALVE OCC / UNOCC COMMAND X X TRI-STATE OUTPUT POINT GENERAL EXHAUST AIR VALVE AIRFLOW FEEDBACK (CFM)X X X GENERAL EXHAUST VALVE POSITION COMMAND X X X GENERAL EXHAUST VALVE MIN AIRFLOW SETPOINT (CFM)X X GENERAL EXHAUST VALVE MAX AIRFLOW SETPOINT (CFM)X X GENERAL EXHAUST VALVE STATUS X X 10% FLOW DEVIATION FROM SETPOINT X TRI-STATE ALARMXVALVE COMMAND NOT EQUAL TO FEEDBACK X LOW DIFFERENTIAL PRESSURE (VIA SWITCH) SUPPLY VALVE FLOW FEEDBACK (CFM)X X X SUPPLY VALVE STATUS X X 10% FLOW DEVIATION FROM SETPOINT X TRI-STATE ALARMXVALVE COMMAND NOT EQUAL TO FEEDBACK X LOW DIFFERENTIAL PRESSURE (VIA SWITCH) SUPPLY VALVE POSITION COMMAND X X X SUPPLY VALVE MIN AIRFLOW SETPOINT (CFM)X X SUPPLY VALVE MAX AIRFLOW SETPOINT (CFM)X X ELECTRIC REHEAT COIL COMMAND X X X X 0 - 10V SIGNAL ELECTRIC REHEAT COIL LEAVING AIR TEMPERATURE X X X SINGLE POINT SENSOR AIRFLOW SENSOR X X X NO FLOW X SPACE TEMPERATURE SETPOINT, HEATING X X X SPACE TEMPERATURE SETPOINT, COOLING X X X SPACE TEMPERATURE X X SPACE TEMPERATURE +/- 4 DEG F FROM SETPOINT X REFER TO PLANS SPACE TEMPERATURE SETPOINT ADJUSTMENT X X REFER TO PLANS SPACE OCCUPANCY X X X X REFER TO PLANS SPACE OCCUPANCY, MINIMUM OCCUPANCY SETPOINT X X X X REFER TO PLANS System Summaries Control Schematics & LAB AIRFLOW SCHEDULE ROOM NUMBER DESCRIPTION ROOM DIMENSIONS CODE MINIMUM VENTILATION EXHAUST AIR SUPPLY AIR XFER (NOTE 1)AREA HEIGHT NYS NYS EXHAUST VALVE VALVE OCCUPIED OCCUPIED UNOCCUPIED UNOCCUPIED UNOCCUPIED SUPPLY VALVE VALVE CANOPY OPEN OCCUPIED SASH OPEN &OCC UNOCC UNOCC UNOCC ALL OUTDOOR EXHAUST POINT SIZE RANGE SASH OPEN SASH CLOSED SASH FULL SASH OPEN SASH CLOSED POINT SIZE RANGE SASH SASH SASH SASH MODES AIRFLOW AIRFLOW (NOTE 4)(NOTE 5)(NOTE 6)(NOTE 7)(NOTE 8)CLOSED (NOTE 4)(NOTE 5)CLOSED FULL OPEN CLOSED (NOTE 2)(NOTE 3)MAX MIN 100 FPM 80 FPM 100 FPM 65 FPM (NOTE 9)MAX MIN 100 FPM 80 FPM (SF)(FT)(CFM)(ACH)(CFM)(ACH)(CFM)(CFM)(CFM)(ACH)(CFM)(ACH)(CFM)(ACH)(CFM)(ACH)(CFM)(ACH)(CFM)(ACH)(CFM)(CFM)(CFM)(CFM)(CFM)(CFM)(CFM)(CFM)(CFM) E334 VAV LAB 491 8.5 198 2.9 491 7.1 FEV-3 10 1300 0 630 9.1 505 7.3 280 6.0 630 9.1 410 5.9 280 4.0 SAV-6 10 1300 0 630 505 420 630 410 280 0GEV-4 8 800 0 0 0 140 0 0 0 TOTAL 630 505 420 630 410 280 NOTES 1.THIS REPRESENTS A LABORATORY WHERE THE REQUIREMENTS OF THE FUME HOODS EXCEEDS THE MINIMUM REQUIRED AIR CHANGE RATES ESTABLISHED FOR THE LABORATORY. 2.. 2 WITH A DEFAULT OCCUPANY DENSITY OF 25 PEOPLE PER 1000 FT 2 CODE MINIMUM OUTDOOR VENTILATION AIRFLOW: NEW YORK STATE UNIFORM MECHANICAL CODE (2020 MCNYS), TABLE 403.3.1.1, OCCUPANCY CLASSIFICATION - EDUCATION SCIENCE LABORATORIES, 10 CFM/PERSON + 0.18 CFM/FT 3.. 2 CODE MINIMUM EXHAUST AIRFLOW: NEW YORK STATE UNIFORM MECHANICAL CODE (2020 MCNYS), TABLE 403.3.1.1, OCCUPANCY CLASSIFICATION - EDUCATION SCIENCE LABORATORIES, 1.0 CFM/FT 4.THE MAX / MIN POSITIONS ON THE VALVE WILL BE SET AT THE FACTORY TO THE FULL FANGE WITH ACTUAL AIRFLOW SET IN SOFTWARE. 5.OCCUPIED SASH OPEN MODE: FUME HOOD EXHAUST AIR FLOW REPRESENTS A 80-100 FPM FACE VELOCITY AT 18-INCH SASH HEIGHT. FUME HOOD AIR VALVE BASIS OF DESIGN WILL BE 100 FPM @ 18-INCHES SASH HEIGHT. FINAL AIRFLOW SETPOINT ESTABLISHED DURING HOOD CERTIFICATION. 6.OCCUPIED SASH CLOSED MODE: CALCULATED BASED ON SPECIFIC HAZARD. 7.UNOCCUPIED SASH FULL MODE: FUME HOOD EXHAUST AIRFLOW REPRESENTS A 100 FPM FACE VELOCITY AT 18-INCH SASH HEIGHT, SASH IS ABOVE 18-INCHES. FUME HOOD EXHAUST SHALL NOT INDEX TO UNOCCUPIED MODE. 8.UNOCCUPIED SASH OPEN MODE: FUME HOOD EXHAUST REPRESENTS AT 65 FPM FACE VELOCITY, SASH IS AT OR BELOW 18-INCHES. FUME HOOD EXHAUST SHALL INDEX TO UNOCCUPIED MODE. 9.UNOCCUPIED SASH CLOSED MODE: CALCULATED BASED ON SPECIFIC HAZARD. SYSTEM DESCRIPTION GENERAL SETPOINTS TOTAL EXHAUST AIR CHANGE RATE (ACPH): REFER TO LAB AIRFLOW SCHEDULES ACPH = TOTAL EXHAUST CFM X 60 / ROOM VOLUME TOTAL EXHAUST AIRFLOW RATE (CFM): REFER TO LAB AIRFLOW SCHEDULES SUPPLY AIRFLOW RATE (CFM): REFER TO LAB AIRFLOW SCHEDULE TYPICALLY = TOTAL EXHAUST AIRFLOW RATE + OFFSET FUME HOOD EXHAUST AIRFLOW RATE: MONITOR TO MAINTAIN FACE VELOCITY SETPOINT. NOT CONTROLLED BY BACS. VALVE IS CONTROLLED BY FUME HOOD FUME HOOD FACE VELOCITY: FPM UNOCC PROGRAMMED INTO FUME HOOD MONITOR. TYPICALLY 80-100 FPM OCC / 65 NOT CONTROLLED BY BACS. FACE VELOCITY SETPOINTS ARE GENERAL EXHASUT AIRFLOW RATE: REFER TO LAB AIRFLOW SCHEDULE TOTAL EXHAUST CFM - FUME HOOD EXHAUST CFM SPACE AIR DIFFERENTIAL OFFSET (CFM): REFER TO LAB AIRFLOW SCHEDULE 30 MINUTESMINIMUM LABORATORY OCCUPANCY INDEX TIME: ZONE OCCUPANCY SCHEDULE: 6 AM TO 8 PM, MON-FRI FACE VELOCITY CONTROL POSITION INDICATOR. THE FUME HOOD SHALL BE EQUIPPED WITH A FUME HOOD MONITOR AND SASH THE FACE VELOCITY SETPOINT. THE MONITOR SHALL ADJUST THE FUME HOOD EXHAUST VALVE TO MAINTAIN THE MONITOR SHALL, AS A MINIMUM, HAVE THE FOLLOWING CAPABILITIES: - SASH POSITION INPUT - STANDBY MODE INPUT TO ALLOW ADJUSTMENT OF FACE VELOCITY. LABORATORY AIRFLOW CONTROL ROOM OCCUPANCY SHALL BE DETERMINED VIA ROOM OCCUPANCY SENSORS. AIR VALVE POSITIONS SHALL BE BASED ON MODE. UNDER NORMAL CONTROL, MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED AIRFLOW DIFFERENTIAL. OCCUPIED AIR CHANGE RATE. THE SUPPLY AIR TERMINAL UNIT SHALL GENERAL EXHAUST AIR VALVE SHALL MODULATE AS NEEDED TO MAINTAIN THE THE OCCUPIED FACE VELOCITY SETPOINT BASED ON THE SASH POSITION. THE SHALL INDEX THE FUME HOOD EXHAUST AIR VALVE AS NEEDED TO MAINTAIN COMMAND TO THE FUME HOOD EXHAUST AIR VALVE. THE FUME HOOD MONITOR WHEN THE ROOM IS OCCUPIED, THE BACS SHALL SEND AN OCCUPIED TO MAINTAIN THE SPECIFIED AIRFLOW DIFFERENTIAL. CHANGE RATE. THE SUPPLY AIR TERMINAL UNIT SHALL MODULATE AS NEEDED AIR VALVE SHALL MODULATE AS NEEDED TO MAINTAIN THE UNOCCUPIED AIR VELOCITY SETPOINT BASED ON THE SASH POSITION. THE GENERAL EXHAUST EXHAUST AIR VALVE AS NEEDED TO MAINTAIN THE UNOCCUPIED FACE EXHAUST AIR VALVE. THE FUME HOOD MONITOR SHALL INDEX THE FUME HOOD THE BACS SHALL SEND AN UNOCCUPIED COMMAND TO THE FUME HOOD WHEN THE ROOM IS UNOCCUPIED, AND THE SASH IS AT OR BELOW 18-INCHES, MAINTAIN THE SPECIFIED AIRFLOW DIFFERENTIAL. RATE. THE SUPPLY AIR TERMINAL UNIT SHALL MODULATE AS REQUIRED TO SHALL MODULATE AS NEEDED TO MAINTAIN THE UNOCCUPIED AIR CHANGE OCCUPIED SASH OPEN AIRFLOW SETPOINT. THE GENERAL EXHAUST AIR VALVE HOOD MONITOR SHALL INDEX THE FUME HOOD EXHAUST AIR TO MAINTAIN THE UNOCCUPIED COMMAND TO THE FUME HOOD EXHAUST AIR VALVE. THE FUME 18-INCHES BASED ON SASH POSITION, THE BACS SHALL NOT SEND THE SPACE WHEN THE ROOM IS UNOCCUPIED AND THE FUME HOOD SASH IS ABOVE CONTROL SHALL TAKE PRIORITY OVER AIR CHANGE CONTROL. IF THE SPACE TEMPERATURE RISES ABOVE SETPOINT, ZONE TEMPERATURE SEQUENCE OF OPERATION GENERAL EXHAUST AIR VALE (GEV) SUPPLY AIR VALVE (SAV) DUCT MOUNTED ELECTRIC REHEAT COIL (RHC) FUME HOOD EXHAUST AIR VALVE (FEV) ZONE TEMPERATURE CONTROL PROGRAMMED SCHEDULE AND SPACE OCCUPANCY SENSORS. SETPOINTS SHALL BE DETERMINED BASED ON A COMBINATION OF VALVE SHALL CLOSE. OCCUPIED COOLING TEMPERATURE SETPOINT, THE REHEAT COIL CONTROL OCCUPIED PERIOD AND THE SPACE TEMPERATURE RISES ABOVE THE OCCUPIED COOLING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED SETBACK TEMPERATURE SETPOINT. SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE MAINTAINED AT THE SCHEDULED OCCUPIED PERIOD, THE ABOVE OCCUPIED HEATING/COOLING OCCUPIED SETBACK: IF THE SPACE BECOMES UNOCCUPIED DURING THE MAINTAINED AT THE UNOCCUPIED SETBACK TEMPERATURE SETPOINT. OCCUPIED HEATING SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE BELOW THE UNOCCUPIED HEATING TEMPERATURE SETPOINT, THE ABOVE SCHEDULED UNOCCUPIED PERIOD AND THE SPACE TEMPERATURE FALLS UNOCCUPIED HEATING: IF THE SPACE IS UNOCCUPIED DURING THE MAINTAINED AT THE UNOCCUPIED COOLING TEMPERATURE SETPOINT. OCCUPIED SETBACK SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE ABOVE THE UNOCCUPIED COOLING TEMPERATURE SETPOINT, THE ABOVE SCHEDULED UNOCCUPIED PERIOD AND THE SPACE TEMPERATURE RISES UNOCCUPIED COOLING: IF THE SPACE IS UNOCCUPIED DURING THE VALVE SHALL BE CLOSED. WHEN THE SPACE TEMPERATURE IS AT SETPOINT, THE REHEAT COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. OCCUPIED HEATING TEMPERATURE SETPOINT, THE REHEAT CONTROL OCCUPIED PERIOD AND THE SPACE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED CONTROL SYSTEM (BACS). SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND ALL SETPOINTS SHALL BE ADJUSTABLE. SETTING DURING A LOSS OF POWER FOR AT LEAST TEN HOURS. THE BACS SHALL BE CAPABLE OF RETAINING ITS PROGRAMMING AND TIME FROM THE SPACE. LABORATORY AIR CHANGE RATES ARE BASED ON TOTAL EXHAUST AIR FLOW HEIGHT). CALCULATE THE REQUIRED CFM USING THE GROSS VOLUME (AREA X CEILING THE SPACE SHALL BE CONTROLLED TO AN AIR CHANGE RATE, THE BACS SHALL SYSTEM SCHEMATIC** **NOTE: FOR VENTURI STYLE VALVES THIS DETAIL SHALL REPLACE THE VALVES SHOWN WITHIN THE S SWITCH. REFER TO PLANS. VENTILATION SHUTDOWN MANUAL BREAK GLASS DOWN SWITCH. SHALL COMMAND CLOSED UPON ACTIVATION OF THE MANUAL VENTILATION SHUT REGARDLESS OF THE OCCUPANCY MODE, THE SUPPLY AND EXHAUST AIR VALVES GDD 585 232 8300 | rochester@swbr.com These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR Architecture, Engineering & Landscape Architecture, D.P.C. and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR Architecture, Engineering & Landscape Architecture, D.P.C. All rights reserved. ©FILE PATH:Checked By: Project Manager: Drawn By: Revisions SWBR Project Number 20636.00 NEER NGENG SyracuseRochester 585.288.5590 Buffalo www.meengineering.com Mechanical/Electrical Engineering Consultants 300 TROLLEY BOULEVARD ROCHESTER, NY 14606 M/E Project #: 200278 Schenectady 387 East Main Street Rochester NY 14604 Cornell University Ithaca, NY Laboratory & Office Renovation Corson Hall Third Floor Documents 100% Construction March 5, 2021 M-201 1 P CONTROLLER ANALOG ELECTRIC MOD AO AV SETPOINT AI AI FLOW ALARM SAV **NOTE: FOR VENTURI STYLE VALVES THIS DETAIL SHALL REPLACE THE VALVES SHOWN WITHIN THE SYSTEM SCHEMATIC** SA H C H C BI OS sa d AI T SETPOINT AV REFER TO PLANS CONTROLLER ANALOG ELECTRIC MOD AO AI AI FLOW ALARM AV SETPOINT P CONTROLLER ANALOG ELECTRIC MOD AO AV SETPOINT AI AI FLOW ALARM GEV AIR EXHAUST SAV IAO ZONE EXHAUST CANOPY HOOD CONTROLLER ANALOG ELECTRIC MOD AO AIAI FLOWALARM AV SETPOINT GEVAIR SUPPLY T AI F AI NOT TO SCALE NMJ NMJ 2 NOT TO SCALE STEAM LOAD SHED MATRIX System Summaries Control Schematics & POINT SCHEDULE EQUIPMENT HARDWARE POINTS SOFTWARE POINTS GRAPHIC SHOWN ON NOTES BI BO AI AO AV BV SCH TREND ALARM BACS EMCS DESCRIPTION STEAM LOAD SHED X (6)BINARY NETWORK INPUTS FROM EMCS CHILLED WATER LOAD SHED X (4)BINARY NETWORK INPUTS FROM EMCS TOTAL EXHAUST AIRFLOW (CFM)X X X TOTAL EXHAUST SETPOINT (CFM)X X X LAB AIR CHANGE RATE (ACPH)X X X ROOM AREA (SQ FT)X X CEILING HEIGHT (FT)X X FLOW OFFSET SETPOINT (CFM)X X FLOW OFFSET ACTUAL (CFM)X X X X X X X X X X X X HOOD EXHAUST VALVE STATUS X X 10% FLOW DEVIATION FROM SETPOINT X TRI-STATE ALARMXVALVE COMMAND NOT EQUAL TO FEEDBACK X LOW DIFFERENTIAL PRESSURE (VIA SWITCH) SUPPLY VALVE FLOW FEEDBACK (CFM)X X X SUPPLY VALVE STATUS X X 10% FLOW DEVIATION FROM SETPOINT X TRI-STATE ALARMXVALVE COMMAND NOT EQUAL TO FEEDBACK X LOW DIFFERENTIAL PRESSURE (VIA SWITCH) SUPPLY VALVE POSITION COMMAND X X X SUPPLY VALVE MIN AIRFLOW SETPOINT (CFM)X X SUPPLY VALVE MAX AIRFLOW SETPOINT (CFM)X X ELECTRIC REHEAT COIL COMMAND X X X X 0 - 10V SIGNAL ELECTRIC REHEAT COIL LEAVING AIR TEMPERATURE X X X SINGLE POINT SENSOR AIRFLOW SENSOR X X X NO FLOW X SPACE TEMPERATURE SETPOINT, HEATING X X X SPACE TEMPERATURE SETPOINT, COOLING X X X SPACE TEMPERATURE X X SPACE TEMPERATURE +/- 4 DEG F FROM SETPOINT X REFER TO PLANS SPACE TEMPERATURE SETPOINT ADJUSTMENT X X REFER TO PLANS SPACE OCCUPANCY X X X X REFER TO PLANS SPACE OCCUPANCY, MINIMUM OCCUPANCY SETPOINT X X X X REFER TO PLANS SYSTEM DESCRIPTION SUPPLY AIR VALVE (SAV) GENERAL CONTROL SYSTEM (BACS). SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND ALL SETPOINTS SHALL BE ADJUSTABLE. SETTING DURING A LOSS OF POWER FOR AT LEAST TEN HOURS. THE BACS SHALL BE CAPABLE OF RETAINING ITS PROGRAMMING AND TIME FROM THE SPACE. LABORATORY AIR CHANGE RATES ARE BASED ON TOTAL EXHAUST AIR FLOW HEIGHT). CALCULATE THE REQUIRED CFM USING THE GROSS VOLUME (AREA X CEILING THE SPACE SHALL BE CONTROLLED TO AN AIR CHANGE RATE, THE BACS SHALL SETPOINTS SPACE COOLING TEMPERATURE SETPOINTS: F 0 75OCCUPIED: F 0 78UNOCCUPIED SETBACK: F 0 81UNOCCUPIED: SPACE HEATING TEMPERATURE SETPOINTS: TOTAL EXHAUST AIR CHANGE RATE (ACPH): REFER TO LAB AIRFLOW SCHEDULES ACPH = TOTAL EXHAUST CFM X 60 / ROOM VOLUME TOTAL EXHAUST AIRFLOW RATE (CFM): REFER TO LAB AIRFLOW SCHEDULE SUPPLY AIRFLOW RATE (CFM): REFER TO LAB AIRFLOW SCHEDULE TYPICALLY = TOTAL EXHAUST AIRFLOW RATE + OFFSET GENERAL EXHAUST AIRFLOW RATE (CFM): REFER TO LAB AIRFLOW SCHEDULE SPACE AIR DIFFERENTIAL OFFSET (CFM): REFER TO LAB AIRFLOW SCHEDULE 30 MINUTESMINIMUM LABORATORY OCCUPANCY INDEX TIME: ZONE OCCUPANCY SCHEDULE: COORDINATE WITH OWNER LABORATORY AIRFLOW CONTROL ROOM OCCUPANCY SHALL BE DETERMINED VIA ROOM OCCUPANCY SENSORS. AIR VALVE POSITIONS SHALL BE BASED ON MODE. UNDER NORMAL CONTROL, AIRFLOW DIFFERENTIAL. SUPPLY AIR VALVE SHALL MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED MODULATE AS NEEDED TO MAINTAIN THE OCCUPIED AIR CHANGE RATE. THE WHEN THE ROOM IS OCCUPIED, THE GENERAL EXHAUST AIR VALVE SHALL AIRFLOW DIFFERENTIAL. SUPPLY AIR VALVE SHALL MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED MODULATE AS NEEDED TO MAINTAIN THE UNOCCUPIED AIR CHANGE RATE. THE WHEN THE ROOM IS UNOCCUPIED, THE GENERAL EXHAUST AIR VALVE SHALL ZONE TEMPERATURE CONTROL PROGRAMMED SCHEDULE AND SPACE OCCUPANCY SENSORS. SETPOINTS SHALL BE DETERMINED BASED ON A COMBINATION OF VALVE SHALL CLOSE. OCCUPIED COOLING TEMPERATURE SETPOINT, THE REHEAT COIL CONTROL OCCUPIED PERIOD AND THE SPACE TEMPERATURE RISES ABOVE THE OCCUPIED COOLING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED SETBACK TEMPERATURE SETPOINT. SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE MAINTAINED AT THE SCHEDULED OCCUPIED PERIOD, THE ABOVE OCCUPIED HEATING/COOLING OCCUPIED SETBACK: IF THE SPACE BECOMES UNOCCUPIED DURING THE MAINTAINED AT THE UNOCCUPIED SETBACK TEMPERATURE SETPOINT. OCCUPIED HEATING SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE BELOW THE UNOCCUPIED HEATING TEMPERATURE SETPOINT, THE ABOVE SCHEDULED UNOCCUPIED PERIOD AND THE SPACE TEMPERATURE FALLS UNOCCUPIED HEATING: IF THE SPACE IS UNOCCUPIED DURING THE MAINTAINED AT THE UNOCCUPIED COOLING TEMPERATURE SETPOINT. OCCUPIED SETBACK SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE ABOVE THE UNOCCUPIED COOLING TEMPERATURE SETPOINT, THE ABOVE SCHEDULED UNOCCUPIED PERIOD AND THE SPACE TEMPERATURE RISES UNOCCUPIED COOLING: IF THE SPACE IS UNOCCUPIED DURING THE SEQUENCE OF OPERATION DUCT MOUNTED ELECTRIC REHEAT COIL (RHC) F0 70OCCUPIED: F0 67UNOCCUPIED SETBACK: F0 64UNOCCUPIED: LAB AIRFLOW SCHEDULE ROOM NUMBER DESCRIPTION ROOM DIMENSIONS CODE MINIMUM VENTILATION EXHAUST AIR SUPPLY AIR XFER (NOTE 1)AREA HEIGHT NYS NYS EXHAUST VALVE VALVE MAX COOLING OCCUPIED UNOCCUPIED SUPPLY VALVE VALVE MAX OCCUPIED UNOCCUPIED ALL OUTDOOR EXHAUST POINT SIZE RANGE POINT SIZE RANGE COOLING MODES AIRFLOW AIRFLOW (NOTE 4)(NOTE 4) (NOTE 2)(NOTE 3)MAX MIN MAX MIN (SF)(FT)(CFM)(ACH)(CFM)(ACH)(CFM)(CFM)(CFM)(ACH)(CFM)(ACH)(CFM)(ACH)(CFM)(CFM)(CFM)(CFM)(CFM)(CFM) E305 COOLING LAB 190 8.5 144 5.4 190 7.1 GEV-3 8 800 0 600 22.3 190 7.1 100 3.7 SAV-2 8 800 80 500 90 0 -100 E318 COOLING LAB 164 8.5 140 6.0 164 7.1 GEV-3 8 800 0 500 21.5 230 9.9 150 6.5 SAV-3 8 800 80 350 80 0 -150 NOTES 1.THIS REPRESENTS A LABORATORY WHERE THE TEMPERATURE REQUIREMENTS (COOLING) OF THE LAB OVERRIDE THE REQUIRED AIR CHANGES. 2. . 2 DENSITY OF 25 PEOPLE PER 1000 FT WITH A DEFAULT OCCUPANY 2 CODE MINIMUM OUTDOOR VENTILATION AIRFLOW: NEW YORK STATE UNIFORM MECHANICAL CODE (2020 MCNYS), TABLE 403.3.1.1, OCCUPANCY CLASSIFICATION - EDUCATION SCIENCE LABORATORIES, 10 CFM/PERSON + 0.18 CFM/FT 3.. 2 CODE MINIMUM EXHAUST AIRFLOW: NEW YORK STATE UNIFORM MECHANICAL CODE (2020 MCNYS), TABLE 403.3.1.1, OCCUPANCY CLASSIFICATION - EDUCATION SCIENCE LABORATORIES, 1.0 CFM/FT 4.THE MAX / MIN POSITIONS ON THE VALVE WILL BE SET AT THE FACTORY TO THE FULL FANGE WITH ACTUAL AIRFLOW SET IN SOFTWARE. STEAM LOAD SHED MATRIX CONTROL POINT LOAD SHED-1 STEAM LOAD SHED-2 STEAM LOAD SHED-3 STEAM LOAD SHED-4 STEAM LOAD SHED-5 STEAM LOAD SHED-6 STEAM ZONE CONTROL RESEARCH SPACES INDEX SPACE TO UNOCCUPIED MODE, RESETTABLE TO OCCUPIED MODE SPACE TEMPERATURE SET POINT TO 60 DEG F INDEX SPACE AIR CHANGE RATE TO MIN UNPCCUPIED AC/PH AND CRITICAL SPACES (2)UNDER CONTROL NOTES: (2)THE DETERMINATION OF WHETHER A SYSTEM OR ZONE IS CONSIDERED "CRITICAL" SHALL BE DETERMINED ON A CASE-BY-CASE BASIS. GENERALLY ANIMAL ROOMS, SERVER ROOMS AND LIBRARIES ARE THE ONLY SPACES THAT ARE PREQUALIFIED AS "CRITICAL" EACH PROJECT SHALL CONDUCT AN INDEPENDENT MEETING WITH THE PRIMARY PURPOSE OF MAKING LOAD SHED DECISIONS VALVE SHALL BE CLOSED. WHEN THE SPACE TEMPERATURE IS AT SETPOINT, THE REHEAT COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. OCCUPIED HEATING TEMPERATURE SETPOINT, THE REHEAT CONTROL OCCUPIED PERIOD AND THE SPACE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED GENERAL EXHAUST AIR VALVE (GEV) LAB E305/E318 WITH SUPPLY AIR VALVE & GENERAL EXHAUST AIR VALVE CONTROL SCHEMATIC AND SYSTEM SUMMARY GENERAL EXHAUST AIR VALVE AIRFLOW FEEDBACK (CFM) GENERAL EXHAUST VALVE POSITION COMMAND GENERAL EXHAUST VALVE MIN AIRFLOW SETPOINT (CFM) GENERAL EXHAUST VALVE MAX AIRFLOW SETPOINT (CFM) S SWITCH. REFER TO PLANS. VENTILATION SHUTDOWN MANUAL BREAK GLASS DOWN SWITCH. SHALL COMMAND CLOSED UPON ACTIVATION OF THE MANUAL VENTILATION SHUT REGARDLESS OF THE OCCUPANCY MODE, THE SUPPLY AND EXHAUST AIR VALVES GDD 585 232 8300 | rochester@swbr.com These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR Architecture, Engineering & Landscape Architecture, D.P.C. and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR Architecture, Engineering & Landscape Architecture, D.P.C. All rights reserved. ©FILE PATH:Checked By: Project Manager: Drawn By: Revisions SWBR Project Number 20636.00 NEER NGENG SyracuseRochester 585.288.5590 Buffalo www.meengineering.com Mechanical/Electrical Engineering Consultants 300 TROLLEY BOULEVARD ROCHESTER, NY 14606 M/E Project #: 200278 Schenectady 387 East Main Street Rochester NY 14604 Cornell University Ithaca, NY Laboratory & Office Renovation Corson Hall Third Floor Documents 100% Construction March 5, 2021 M-202 1 P CONTROLLER ANALOG ELECTRIC MOD AO AV SETPOINT AI AI FLOW ALARM SAV **NOTE: FOR VENTURI STYLE VALVES THIS DETAIL SHALL REPLACE THE VALVES SHOWN WITHIN THE SYSTEM SCHEMATIC** SA H C H C BI OS sa d AI T SETPOINT AV REFER TO PLANS CONTROLLER ANALOG ELECTRIC MOD AO AI AI FLOW ALARM AV SETPOINT P CONTROLLER ANALOG ELECTRIC MOD AO AV SETPOINT AI AI FLOW ALARM GEV AIR EXHAUST SAV IAO ZONE EXHAUST CANOPY HOOD CONTROLLER ANALOG ELECTRIC MOD AO AIAI FLOWALARM AV SETPOINT FEVAIR SUPPLY T AI F AI SLOT HOOD POINT SCHEDULE EQUIPMENT HARDWARE POINTS SOFTWARE POINTS GRAPHIC SHOWN ON NOTES BI BO AI AO AV BV SCH TREND ALARM BACS EMCS DESCRIPTION STEAM LOAD SHED X (6)BINARY NETWORK INPUTS FROM EMCS CHILLED WATER LOAD SHED X (4)BINARY NETWORK INPUTS FROM EMCS TOTAL EXHAUST AIRFLOW (CFM)X X X TOTAL EXHAUST SETPOINT (CFM)X X X LAB AIR CHANGE RATE (ACPH)X X X ROOM AREA (SQ FT)X X CEILING HEIGHT (FT)X X FLOW OFFSET SETPOINT (CFM)X X FLOW OFFSET ACTUAL (CFM)X X HOOD EXHAUST AIR VALVE AIRFLOW FEEDBACK (CFM)X X X HOOD EXHAUST VALVE POSITION COMMAND X X X HOOD EXHAUST VALVE MIN AIRFLOW SETPOINT (CFM)X X HOOD EXHAUST VALVE MAX AIRFLOW SETPOINT (CFM)X X HOOD EXHAUST VALVE STATUS X X 10% FLOW DEVIATION FROM SETPOINT X TRI-STATE ALARMXVALVE COMMAND NOT EQUAL TO FEEDBACK X LOW DIFFERENTIAL PRESSURE (VIA SWITCH) SUPPLY VALVE FLOW FEEDBACK (CFM)X X X SUPPLY VALVE STATUS X X 10% FLOW DEVIATION FROM SETPOINT X TRI-STATE ALARMXVALVE COMMAND NOT EQUAL TO FEEDBACK X LOW DIFFERENTIAL PRESSURE (VIA SWITCH) SUPPLY VALVE POSITION COMMAND X X X SUPPLY VALVE MIN AIRFLOW SETPOINT (CFM)X X SUPPLY VALVE MAX AIRFLOW SETPOINT (CFM)X X ELECTRIC REHEAT COIL COMMAND X X X X 0 - 10V SIGNAL ELECTRIC REHEAT COIL LEAVING AIR TEMPERATURE X X X SINGLE POINT SENSOR AIRFLOW SENSOR X X X NO FLOW X SPACE TEMPERATURE SETPOINT, HEATING X X X SPACE TEMPERATURE SETPOINT, COOLING X X X SPACE TEMPERATURE X X SPACE TEMPERATURE +/- 4 DEG F FROM SETPOINT X REFER TO PLANS SPACE TEMPERATURE SETPOINT ADJUSTMENT X X REFER TO PLANS SPACE OCCUPANCY X X X X REFER TO PLANS SPACE OCCUPANCY, MINIMUM OCCUPANCY SETPOINT X X X X REFER TO PLANS LAB E334A WITH SUPPLY AIR VALVE & SLOT HOOD EXHAUST AIR VALVE CONTROL SCHEMATIC AND SYSTEM SUMMARY NOT TO SCALE NMJ NMJ 1 NOT TO SCALE CHILLED WATER LOAD SHED MATRIX CHILLED WATER LOAD SHED MATRIX CONTROL POINT DAYTIME (DEFCON 3) LOAD SHED 1 - CHILLED WATER (DEFCON 2) LOAD SHED 2 - CHILLED WATER NIGHT EMERGENCY (DEFCON 1) LOAD SHED 3 - CHILLED WATER EMERGENCY (DEFCON) LOAD SHED 4 - CHILLED WATER LCS ZONE CONTROL RESEARCH SPACES INDEX SPACE TO UNOCCUPIED MODE, RESTTABLE TO OCCUPIED MODE VALVE CLOSED INDEX CHILLED WATER CONTROL CRITICAL SPACES (2)UNDER CONTROL NOTES: (1)THE DETERMINATION OF WHETHER A SYSTEM OR ZONE IS CONSIDERED "CRITICAL" SHALL BE DETERMINED ON A CASE-BY-CASE BASIS. GENERALLY ANIMAL ROOMS, SERVER ROOMS AND LIBRARIES ARE THE ONLY SPACES THAT ARE PREQUALIFIED AS "CRITICAL" EACH PROJECT SHALL CONDUCT AN INDEPENDENT MEETING WITH THE PRIMARY PURPOSE OF MAKING LOAD SHED DECISIONS System Summaries Control Schematics & LAB AIRFLOW SCHEDULE ROOM NUMBER DESCRIPTION ROOM DIMENSIONS CODE MINIMUM VENTILATION EXHAUST AIR SUPPLY AIR XFER (NOTE 1)AREA HEIGHT NYS NYS EXHAUST VALVE VALVE OCCUPIED UNOCCUPIED SUPPLY VALVE VALVE OCCUPIED UNOCCUPIED ALL OUTDOOR EXHAUST POINT SIZE RANGE (NOTE 5)POINT SIZE RANGE (NOTE 5)MODES AIRFLOW AIRFLOW (NOTE 4)(NOTE 4) (NOTE 2)(NOTE 3)MAX MIN MAX MIN (SF)(FT)(CFM)(ACH)(CFM)(ACH)(CFM)(CFM)(CFM)(ACH)(CFM)(ACH)(CFM)(CFM)(CFM)(CFM)(CFM) E334A ACHR LAB 68 8.5 22 2.3 68 7.1 FEV-2 8"800 0 500 51.9 125 13.0 SAV-5 8"800 0 375 0 -125 NOTES 1.THIS REPRESENTS A LABORATORY WHERE THE MINIMUM REQUIRED AIR CHANGE RATES ESTABLISHED FOR THE LABORATORY DRIVES THE EXHAUST RATE 2.CFM/SQFT WITH A DEFAULT OCCUPANY DENSITY OF 25 PEOPLE PER 1000 SQFT. CODE MINIMUM OUTDOOR VENTILATION AIRFLOW: NEW YORK STATE UNIFORM MECHANICAL CODE (2020 MCNYS), TABLE 403.3.1.1, OCCUPANCY CLASSIFICATION - EDUCATION SCIENCE LABORATORIES, 10 CFM/PERSON + 0.18 3.CODE MINIMUM EXHAUST AIRFLOW: NEW YORK STATE UNIFORM MECHANICAL CODE (2020 MCNYS), TABLE 403.3.1.1, OCCUPANCY CLASSIFICATION - EDUCATION SCIENCE LABORATORIES, 1.0 CFM/SQFT. 4.THE MAX / MIN POSITIONS ON THE VALVE WILL BE SET AT THE FACTORY TO THE FULL FANGE WITH ACTUAL AIRFLOW SET IN SOFTWARE. SYSTEM DESCRIPTION SUPPLY AIR VALVE (SAV) GENERAL CONTROL SYSTEM (BACS). SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND ALL SETPOINTS SHALL BE ADJUSTABLE. SETTING DURING A LOSS OF POWER FOR AT LEAST TEN HOURS. THE BACS SHALL BE CAPABLE OF RETAINING ITS PROGRAMMING AND TIME FROM THE SPACE. LABORATORY AIR CHANGE RATES ARE BASED ON TOTAL EXHAUST AIR FLOW HEIGHT). CALCULATE THE REQUIRED CFM USING THE GROSS VOLUME (AREA X CEILING THE SPACE SHALL BE CONTROLLED TO AN AIR CHANGE RATE, THE BACS SHALL SETPOINTS SPACE COOLING TEMPERATURE SETPOINTS: F 0 75OCCUPIED: F 0 78UNOCCUPIED SETBACK: F 0 81UNOCCUPIED: SPACE HEATING TEMPERATURE SETPOINTS: TOTAL EXHAUST AIR CHANGE RATE (ACPH): REFER TO LAB AIRFLOW SCHEDULES ACPH = TOTAL EXHAUST CFM X 60 / ROOM VOLUME TOTAL EXHAUST AIRFLOW RATE (CFM): REFER TO LAB AIRFLOW SCHEDULE SUPPLY AIRFLOW RATE (CFM): REFER TO LAB AIRFLOW SCHEDULE TYPICALLY = TOTAL EXHAUST AIRFLOW RATE + OFFSET GENERAL EXHAUST AIRFLOW RATE (CFM): REFER TO LAB AIRFLOW SCHEDULE SPACE AIR DIFFERENTIAL OFFSET (CFM): REFER TO LAB AIRFLOW SCHEDULE 30 MINUTESMINIMUM LABORATORY OCCUPANCY INDEX TIME: ZONE OCCUPANCY SCHEDULE: COORDINATE WITH OWNER LABORATORY AIRFLOW CONTROL ROOM OCCUPANCY SHALL BE DETERMINED VIA ROOM OCCUPANCY SENSORS. AIR VALVE POSITIONS SHALL BE BASED ON MODE. UNDER NORMAL CONTROL, AIRFLOW DIFFERENTIAL. SUPPLY AIR VALVE SHALL MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED MODULATE AS NEEDED TO MAINTAIN THE OCCUPIED AIR CHANGE RATE. THE WHEN THE ROOM IS OCCUPIED, THE GENERAL EXHAUST AIR VALVE SHALL AIRFLOW DIFFERENTIAL. SUPPLY AIR VALVE SHALL MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED MODULATE AS NEEDED TO MAINTAIN THE UNOCCUPIED AIR CHANGE RATE. THE WHEN THE ROOM IS UNOCCUPIED, THE GENERAL EXHAUST AIR VALVE SHALL ZONE TEMPERATURE CONTROL PROGRAMMED SCHEDULE AND SPACE OCCUPANCY SENSORS. SETPOINTS SHALL BE DETERMINED BASED ON A COMBINATION OF VALVE SHALL CLOSE. OCCUPIED COOLING TEMPERATURE SETPOINT, THE REHEAT COIL CONTROL OCCUPIED PERIOD AND THE SPACE TEMPERATURE RISES ABOVE THE OCCUPIED COOLING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED SETBACK TEMPERATURE SETPOINT. SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE MAINTAINED AT THE SCHEDULED OCCUPIED PERIOD, THE ABOVE OCCUPIED HEATING/COOLING OCCUPIED SETBACK: IF THE SPACE BECOMES UNOCCUPIED DURING THE MAINTAINED AT THE UNOCCUPIED SETBACK TEMPERATURE SETPOINT. OCCUPIED HEATING SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE BELOW THE UNOCCUPIED HEATING TEMPERATURE SETPOINT, THE ABOVE SCHEDULED UNOCCUPIED PERIOD AND THE SPACE TEMPERATURE FALLS UNOCCUPIED HEATING: IF THE SPACE IS UNOCCUPIED DURING THE MAINTAINED AT THE UNOCCUPIED COOLING TEMPERATURE SETPOINT. OCCUPIED SETBACK SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE ABOVE THE UNOCCUPIED COOLING TEMPERATURE SETPOINT, THE ABOVE SCHEDULED UNOCCUPIED PERIOD AND THE SPACE TEMPERATURE RISES UNOCCUPIED COOLING: IF THE SPACE IS UNOCCUPIED DURING THE SEQUENCE OF OPERATION DUCT MOUNTED ELECTRIC REHEAT COIL (RHC) F0 70OCCUPIED: F0 67UNOCCUPIED SETBACK: F0 64UNOCCUPIED: VALVE SHALL BE CLOSED. WHEN THE SPACE TEMPERATURE IS AT SETPOINT, THE REHEAT COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. OCCUPIED HEATING TEMPERATURE SETPOINT, THE REHEAT CONTROL OCCUPIED PERIOD AND THE SPACE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED SLOT HOOD EXHAUST AIR VALVE (FEV) GDD 585 232 8300 | rochester@swbr.com These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR Architecture, Engineering & Landscape Architecture, D.P.C. and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR Architecture, Engineering & Landscape Architecture, D.P.C. All rights reserved. ©FILE PATH:Checked By: Project Manager: Drawn By: Revisions SWBR Project Number 20636.00 NEER NGENG SyracuseRochester 585.288.5590 Buffalo www.meengineering.com Mechanical/Electrical Engineering Consultants 300 TROLLEY BOULEVARD ROCHESTER, NY 14606 M/E Project #: 200278 Schenectady 387 East Main Street Rochester NY 14604 Cornell University Ithaca, NY Laboratory & Office Renovation Corson Hall Third Floor Documents 100% Construction March 5, 2021 M-203 1 P CONTROLLER ANALOG ELECTRIC MOD AO AV SETPOINT AI AI FLOW ALARM SAV SA H C H C sa d AI T SETPOINT AV REFER TO PLANS CONTROLLER ANALOG ELECTRIC MOD AO AI AI FLOW ALARM AV SETPOINT SAV IAO ZONE AIR SUPPLY T AI F AI LAB E334B WITH SUPPLY AIR VALVE CONTROL SCHEMATIC AND SYSTEM SUMMARY NOT TO SCALE REPLACE THE VALVES SHOWN WITHIN THE SYSTEM SCHEMATIC** **NOTE: FOR VENTURI STYLE VALVES THIS DETAIL SHALL NMJ NMJ 2 NOT TO SCALE MISCELLANEOUS ELECTRICAL CONTROL SCHEMATIC AND SYSTEM SUMMARY POINT SCHEDULE MISCELLANEOUS ELECTRICAL HARDWARE POINTS SOFTWARE POINTS GRAPHIC SHOWN ON NOTES BI BO AI AO AV BV SCH TREND ALARM BACS EMCS DESCRIPTION FREEZER STATUS X X HIGH TEMPERATURE X REFRIGERATOR STATUS X X HIGH TEMPERATURE X System Summaries Control Schematics & LAB AIRFLOW SCHEDULE ROOM NUMBER DESCRIPTION ROOM DIMENSIONS CODE MINIMUM VENTILATION EXHAUST AIR SUPPLY AIR XFER (NOTE 1)AREA HEIGHT NYS NYS EXHAUST VALVE VALVE OCCUPIED UNOCCUPIED SUPPLY VALVE VALVE OCCUPIED UNOCCUPIED ALL OUTDOOR EXHAUST POINT SIZE RANGE (NOTE 5)POINT SIZE RANGE MODES AIRFLOW AIRFLOW (NOTE 4)(NOTE 4) (NOTE 2)(NOTE 3)MAX MIN MAX MIN (SF)(FT)(CFM)(ACH)(CFM)(ACH)(CFM)(CFM)(CFM)(ACH)(CFM)(ACH)(CFM)(CFM)(CFM)(CFM)(CFM) E334A ACHR LAB 55 8.5 20 2.6 55 7.1 --------SAV-4 8"800 0 125 125 125 NOTES 1.THIS REPRESENTS A LABORATORY WHERE THE MINIMUM REQUIRED AIR CHANGE RATES ESTABLISHED FOR THE LABORATORY DRIVES THE EXHAUST RATE 2.CFM/SQFT WITH A DEFAULT OCCUPANY DENSITY OF 25 PEOPLE PER 1000 SQFT. CODE MINIMUM OUTDOOR VENTILATION AIRFLOW: NEW YORK STATE UNIFORM MECHANICAL CODE (2020 MCNYS), TABLE 403.3.1.1, OCCUPANCY CLASSIFICATION - EDUCATION SCIENCE LABORATORIES, 10 CFM/PERSON + 0.18 3.CODE MINIMUM EXHAUST AIRFLOW: NEW YORK STATE UNIFORM MECHANICAL CODE (2020 MCNYS), TABLE 403.3.1.1, OCCUPANCY CLASSIFICATION - EDUCATION SCIENCE LABORATORIES, 1.0 CFM/SQFT. 4.THE MAX / MIN POSITIONS ON THE VALVE WILL BE SET AT THE FACTORY TO THE FULL FANGE WITH ACTUAL AIRFLOW SET IN SOFTWARE. SYSTEM DESCRIPTION GENERAL EXHAUST AIR VALE (GEV) GENERAL CONTROL SYSTEM (BACS). SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND ALL SETPOINTS SHALL BE ADJUSTABLE. SETTING DURING A LOSS OF POWER FOR AT LEAST TEN HOURS. THE BACS SHALL BE CAPABLE OF RETAINING ITS PROGRAMMING AND TIME SEQUENCE OF OPERATION SETPOINTS SPACE COOLING TEMPERATURE SETPOINTS: F 0 75OCCUPIED: F 0 78UNOCCUPIED SETBACK: F 0 81UNOCCUPIED: SPACE HEATING TEMPERATURE SETPOINTS: F0 70OCCUPIED: F0 67UNOCCUPIED SETBACK: F0 64UNOCCUPIED: LABORATORY AIRFLOW CONTROL ROOM OCCUPANCY SHALL BE DETERMINED VIA ROOM OCCUPANCY SENSORS. AIR VALVE POSITIONS SHALL BE BASED ON MODE. UNDER NORMAL CONTROL, ZONE TEMPERATURE CONTROL PROGRAMMED SCHEDULE AND SPACE OCCUPANCY SENSORS. SETPOINTS SHALL BE DETERMINED BASED ON A COMBINATION OF VALVE SHALL CLOSE. OCCUPIED COOLING TEMPERATURE SETPOINT, THE REHEAT COIL CONTROL OCCUPIED PERIOD AND THE SPACE TEMPERATURE RISES ABOVE THE OCCUPIED COOLING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED SETBACK TEMPERATURE SETPOINT. SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE MAINTAINED AT THE SCHEDULED OCCUPIED PERIOD, THE ABOVE OCCUPIED HEATING/COOLING OCCUPIED SETBACK: IF THE SPACE BECOMES UNOCCUPIED DURING THE MAINTAINED AT THE UNOCCUPIED SETBACK TEMPERATURE SETPOINT. OCCUPIED HEATING SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE BELOW THE UNOCCUPIED HEATING TEMPERATURE SETPOINT, THE ABOVE SCHEDULED UNOCCUPIED PERIOD AND THE SPACE TEMPERATURE FALLS UNOCCUPIED HEATING: IF THE SPACE IS UNOCCUPIED DURING THE MAINTAINED AT THE UNOCCUPIED COOLING TEMPERATURE SETPOINT. OCCUPIED SETBACK SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE ABOVE THE UNOCCUPIED COOLING TEMPERATURE SETPOINT, THE ABOVE SCHEDULED UNOCCUPIED PERIOD AND THE SPACE TEMPERATURE RISES UNOCCUPIED COOLING: IF THE SPACE IS UNOCCUPIED DURING THE VALVE SHALL BE CLOSED. WHEN THE SPACE TEMPERATURE IS AT SETPOINT, THE REHEAT COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. OCCUPIED HEATING TEMPERATURE SETPOINT, THE REHEAT CONTROL OCCUPIED PERIOD AND THE SPACE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED MAINTAIN SCHEDULED AIRFLOW. DURING OCCUPIED AND UNOCCUPIED MODES, THE SUPPLY AIR VALVE SHALL POINT SCHEDULE EQUIPMENT HARDWARE POINTS SOFTWARE POINTS GRAPHIC SHOWN ON NOTES BI BO AI AO AV BV SCH TREND ALARM BACS EMCS DESCRIPTION STEAM LOAD SHED X (6)BINARY NETWORK INPUTS FROM EMCS CHILLED WATER LOAD SHED X (4)BINARY NETWORK INPUTS FROM EMCS LAB AIR CHANGE RATE (ACPH)X X X ROOM AREA (SQ FT)X X CEILING HEIGHT (FT)X X FLOW OFFSET SETPOINT (CFM)X X FLOW OFFSET ACTUAL (CFM)X X SUPPLY VALVE FLOW FEEDBACK (CFM)X X X SUPPLY VALVE STATUS X X 10% FLOW DEVIATION FROM SETPOINT X TRI-STATE ALARMXVALVE COMMAND NOT EQUAL TO FEEDBACK X LOW DIFFERENTIAL PRESSURE (VIA SWITCH) SUPPLY VALVE POSITION COMMAND X X X SUPPLY VALVE MIN AIRFLOW SETPOINT (CFM)X X SUPPLY VALVE MAX AIRFLOW SETPOINT (CFM)X X ELECTRIC REHEAT COIL COMMAND X X X X 0 - 10V SIGNAL ELECTRIC REHEAT COIL LEAVING AIR TEMPERATURE X X X SINGLE POINT SENSOR AIRFLOW SENSOR X X X NO FLOW X SPACE TEMPERATURE SETPOINT, HEATING X X X SPACE TEMPERATURE SETPOINT, COOLING X X X SPACE TEMPERATURE X X SPACE TEMPERATURE +/- 4 DEG F FROM SETPOINT X REFER TO PLANS SPACE TEMPERATURE SETPOINT ADJUSTMENT X X REFER TO PLANS GDD 585 232 8300 | rochester@swbr.com These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR Architecture, Engineering & Landscape Architecture, D.P.C. and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR Architecture, Engineering & Landscape Architecture, D.P.C. All rights reserved. ©FILE PATH:Checked By: Project Manager: Drawn By: Revisions SWBR Project Number 20636.00 NEER NGENG SyracuseRochester 585.288.5590 Buffalo www.meengineering.com Mechanical/Electrical Engineering Consultants 300 TROLLEY BOULEVARD ROCHESTER, NY 14606 M/E Project #: 200278 Schenectady 387 East Main Street Rochester NY 14604 Cornell University Ithaca, NY Laboratory & Office Renovation Corson Hall Third Floor Documents 100% Construction March 5, 2021 CMD GDD M-204 P CONTROLLER ANALOG ELECTRIC MOD AO AV SETPOINT AI AI FLOW ALARM SAV **NOTE: FOR VENTURI STYLE VALVES THIS DETAIL SHALL REPLACE THE VALVES SHOWN WITHIN THE SYSTEM SCHEMATIC** SA H C H C AIR SUPPLY BI OS sa d AI T AI T SETPOINT AV REFER TO PLANS AO AO MONITOR HOOD FUME - ALARM - SASH POSITION FEEDBACK - VALVE POSITION COMMAND INTERFACE CARD: EXHAUST VALVE HOOD FUME HOOD MONITOR TO ANALOG POINT FROM EXHAUST FUME HOOD INDICATOR SASH POSITION VERTICAL HOOD INTERFACE CARDCONTROLLER WITHANALOG ELECTRICAO AI AI FLOW ALARM R COMMAND VACANCY UNOCCUPIED OCCUPIED/ AI SASH P HOOD INTERFACE CARDCONTROLLER WITHANALOG ELECTRICAO AI AI FLOW ALARM R COMMAND VACANCY UNOCCUPIED OCCUPIED/ AI SASHFEV - ALARM - SASH POSITION FEEDBACK - VALVE POSITION COMMAND INTERFACE CARD: EXHAUST VALVE HOOD FUME HOOD MONITOR TO ANALOG POINT FROM EA CONTROLLER ANALOG ELECTRIC MOD AO AI AI FLOW ALARM AV SETPOINT 1 N.T.S FEVSAV FACE VELOCITY CONTROL POSITION INDICATOR. THE FUME HOOD SHALL BE EQUIPPED WITH A FUME HOOD MONITOR AND SASH THE FACE VELOCITY SETPOINT. THE MONITOR SHALL ADJUST THE FUME HOOD EXHAUST VALVE TO MAINTAIN THE MONITOR SHALL, AS A MINIMUM, HAVE THE FOLLOWING CAPABILITIES: - SASH POSITION INPUT - STANDBY MODE INPUT TO ALLOW ADJUSTMENT OF FACE VELOCITY. LABORATORY AIRFLOW CONTROL AIRFLOW DIFFERENTIAL. SUPPLY AIR VALVE SHALL MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED THE OCCUPIED FACE VELOCITY SETPOINT BASED ON THE SASH POSITION. THE SHALL INDEX THE FUME HOOD EXHAUST AIR VALVE AS NEEDED TO MAINTAIN COMMAND TO THE FUME HOOD EXHAUST AIR VALVE. THE FUME HOOD MONITOR WHEN THE ROOM IS OCCUPIED, THE BACS SHALL SEND AN OCCUPIED DIFFERENTIAL. SHALL MODULATE AS NEEDED TO MAINTAIN THE SPECIFIED AIRFLOW VELOCITY SETPOINT BASED ON THE SASH POSITION. THE SUPPLY AIR VALVE EXHAUST AIR VALVE AS NEEDED TO MAINTAIN THE UNOCCUPIED FACE EXHAUST AIR VALVE. THE FUME HOOD MONITOR SHALL INDEX THE FUME HOOD THE BACS SHALL SEND AN UNOCCUPIED COMMAND TO THE FUME HOOD WHEN THE ROOM IS UNOCCUPIED, AND THE SASH IS AT OR BELOW 18-INCHES, (MINIMUM TWO PER LAB). ROOM OCCUPANCY SHALL BE DETERMINED VIA ROOM OCCUPANCY SENSORS AIR VALVE POSITIONS SHALL BE BASED ON MODE. UNDER NORMAL CONTROL, ZONE TEMPERATURE CONTROL TOTAL EXHAUST AIR CHANGE RATE (ACPH): REFER TO LAB AIRFLOW SCHEDULES ACPH = TOTAL EXHAUST CFM X 60 / ROOM VOLUME TOTAL EXHAUST AIRFLOW RATE (CFM): REFER TO LAB AIRFLOW SCHEDULES SUPPLY AIRFLOW RATE (CFM): REFER TO LAB AIRFLOW SCHEDULE TYPICALLY = TOTAL EXHAUST AIRFLOW RATE + OFFSET FUME HOOD EXHAUST AIRFLOW RATE: MONITOR TO MAINTAIN FACE VELOCITY SETPOINT. NOT CONTROLLED BY BACS. VALVE IS CONTROLLED BY FUME HOOD FUME HOOD FACE VELOCITY: FPM UNOCC PROGRAMMED INTO FUME HOOD MONITOR. TYPICALLY 80-100 FPM OCC / 65 NOT CONTROLLED BY BACS. FACE VELOCITY SETPOINTS ARE SPACE AIR DIFFERENTIAL OFFSET (CFM): REFER TO LAB AIRFLOW SCHEDULES 30 MINUTESMINIMUM LABORATORY OCCUPANCY INDEX TIME: ZONE OCCUPANCY SCHEDULE: COORDINATE WITH OWNER SEQUENCE OF OPERATION SETPOINTS SPACE COOLING TEMPERATURE SETPOINTS: OCCUPIED:7 7OCCUPIED SETBACK: 8UNOCCUPIED: SPACE HEATING TEMPERATURE SETPOINTS: OCCUPIED:7 6OCCUPIED SETBACK: 64UNOCCUPIED: MAINTAIN THE SPECIFIED AIRFLOW DIFFERENTIAL. POSITION. THE SUPPLY AIR VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN THE UNOCCUPIED FACE VELOCITY SETPOINT BASED ON THE SASH EXHAUST AIR VALVES WHOSE SASHES ARE AT 18-INCHES AND BELOW TO BELOW 18-INCHES. THE FUME HOOD MONITOR SHALL INDEX THE FUME HOOD UNOCCUPIED COMMAND TO THOSE FUME HOODS WHOSE SASHES ARE AT OR OCCUPIED SASH OPEN AIRFLOW SETPOINT. THE BACS WILL SEND THE AIR VALVES WHOSES SASHES ARE ABOVE THE 18-INCHES TO MAINTAIN THE AIR VALVES. THE FUME HOOD MONITOR SHALL INDEX THE FUME HOOD EXHAUST SPACE UNOCCUPIED COMMAND TO THOSE PARTICULAR FUME HOOD EXHAUST ABOVE 18-INCHES BASED ON SASH POSITION, THE BACS SHALL NOT SEND THE WHEN THE ROOM IS UNOCCUPIED AND ANY OF THE FUME HOOD SASHES ARE (BACS). BUILDING AUTOMATION ANDCONTROL SYSTEM SYSTEM SHALL BE CONTROLLED THROUGH THE TOTAL EXHAUST AIRFLOWFROM THE SPACE. LABORATORY AIR CHANGE RATES ARE BASED ON CEILING HEIGHT).VOLUME (AREA x THE REQUIRED CFM USING THE ROOM GROSS CHANGE RATE. THE BACS SHALL CALCULATE THE SPACE SHALL BE CONTROLLED TO AN AIR ALL SETPOINTS SHALL BE ADJUSTABLE. SYSTEM DESCRIPTION FUME HOOD EXHAUST AIR VALVE SUPPLY AIR VALVE GENERAL MODULATE AIRFLOW. CURRENTLY HAVE THE CAPABILITY TO SYSTEM IS CONSTANT VOLUME AND DOES NOT CANOPY HOOD EXHAUST AIR VALVE CANOPY HOOD FUME HOOD MOTORIZED IAO EXHAUST CANOPY HOOD DUCT MOUNTED ELECTRIC REHEAT COIL LAB E304 WITH SUPPLY AIR VALVE, FUME HOOD EXHAUST AIR VALVE & CANOPY HOOD EXHAUST AIR VALVE CONTROL SCHEMATIC AND SYSTEM SUMMARY ZONE F AI CONTROLLER ANALOG ELECTRIC MOD AO AI AI FLOW ALARM AV SETPOINT GEV AI T PROGRAMMED SCHEDULE AND SPACE OCCUPANCY SENSORS. SETPOINTS SHALL BE DETERMINED BASED ON A COMBINATION OF AND REHEAT COIL CONTROL VALVES SHALL BE CLOSED. WHEN THE SPACE TEMPERATURE IS AT SETPOINT, THE BASEBOARD RADIATION VALVE SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. BASEBOARD RADIATION CONTROL VALVE FULLY OPEN, THE REHEAT CONTROL SETPOINT. IF THE SPACE TEMPERATURE IS NOT AT SETPOINT WITH THE CONTROL VALVE SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE OCCUPIED HEATING TEMPERATURE SETPOINT, THE BASEBOARD RADIATION OCCUPIED PERIOD AND THE SPACE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED VALVE SHALL CLOSE. OCCUPIED COOLING TEMPERATURE SETPOINT, THE REHEAT COIL CONTROL OCCUPIED PERIOD AND THE SPACE TEMPERATURE RISES ABOVE THE OCCUPIED COOLING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED SETBACK TEMPERATURE SETPOINT. SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE MAINTAINED AT THE SCHEDULED OCCUPIED PERIOD, THE ABOVE OCCUPIED HEATING/COOLING OCCUPIED SETBACK: IF THE SPACE BECOMES UNOCCUPIED DURING THE MAINTAINED AT THE UNOCCUPIED SETBACK TEMPERATURE SETPOINT. OCCUPIED HEATING SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE BELOW THE UNOCCUPIED HEATING TEMPERATURE SETPOINT, THE ABOVE SCHEDULED UNOCCUPIED PERIOD AND THE SPACE TEMPERATURE FALLS UNOCCUPIED HEATING: IF THE SPACE IS UNOCCUPIED DURING THE MAINTAINED AT THE UNOCCUPIED COOLING TEMPERATURE SETPOINT. OCCUPIED SETBACK SEQUENCE SHALL APPLY, BUT THE SPACE SHALL BE ABOVE THE UNOCCUPIED COOLING TEMPERATURE SETPOINT, THE ABOVE SCHEDULED UNOCCUPIED PERIOD AND THE SPACE TEMPERATURE RISES UNOCCUPIED COOLING: IF THE SPACE IS UNOCCUPIED DURING THE Summaries System Control Schematics & LAB AIRFLOW SCHEDULE ROOM NUMBER DESCRIPTION ROOM DIMENSIONS CODE MINIMUM VENTILATION EXHAUST AIR SUPPLY AIR XFER (NOTE 1)AREA HEIGHT NYS NYS EXHAUST VALVE VALVE OCCUPIED OCCUPIED UNOCCUPIED UNOCCUPIED UNOCCUPIED SUPPLY VALVE VALVE CANOPY OPEN OCCUPIED SASH OPEN &OCC UNOCC UNOCC UNOCC ALL OUTDOOR EXHAUST POINT SIZE RANGE SASH OPEN & CANOPY ON SASH CLOSED SASH FULL SASH OPEN SASH CLOSED POINT SIZE RANGE SASH SASH SASH SASH MODES AIRFLOW AIRFLOW (NOTE 4)(NOTE 5)CANOPY OFF (NOTE 7)(NOTE 8)CLOSED (NOTE 4)(NOTE 5)CLOSED FULL OPEN CLOSED (NOTE 2)(NOTE 3)MAX MIN 100 FPM 80 FPM (NOTE 6)100 FPM 65 FPM (NOTE 9)MAX MIN 100 FPM 80 FPM (SF)(FT)(CFM)(ACH)(CFM)(ACH)(CFM)(CFM)(CFM)(ACH)(CFM)(ACH)(CFM)(ACH)(CFM)(ACH)(CFM)(ACH)(CFM)(ACH)(CFM)(CFM)(CFM)(CFM)(CFM)(CFM)(CFM)(CFM)(CFM) 304/304B VAV LAB 385 8.5 179 3.3 385 7.1 FEV-1 10 1300 0 630 20.7 505 18.4 280 5.1 630 11.6 410 7.5 280 5.1 SAV-1 12 1790 0 1030 905 180 530 310 180 -100GEV-1 8 800 0 500 500 0 0 0 0 TOTAL 1130 1005 280 630 410 280 NOTES 1.THIS REPRESENTS A LABORATORY WHERE THE REQUIREMENTS OF THE FUME HOODS EXCEEDS THE MINIMUM REQUIRED AIR CHANGE RATES ESTABLISHED FOR THE LABORATORY. 2.. 2 WITH A DEFAULT OCCUPANY DENSITY OF 25 PEOPLE PER 1000 FT 2 CODE MINIMUM OUTDOOR VENTILATION AIRFLOW: NEW YORK STATE UNIFORM MECHANICAL CODE (2020 MCNYS), TABLE 403.3.1.1, OCCUPANCY CLASSIFICATION - EDUCATION SCIENCE LABORATORIES, 10 CFM/PERSON + 0.18 CFM/FT 3.. 2 CODE MINIMUM EXHAUST AIRFLOW: NEW YORK STATE UNIFORM MECHANICAL CODE (2020 MCNYS), TABLE 403.3.1.1, OCCUPANCY CLASSIFICATION - EDUCATION SCIENCE LABORATORIES, 1.0 CFM/FT 4.THE MAX / MIN POSITIONS ON THE VALVE WILL BE SET AT THE FACTORY TO THE FULL FANGE WITH ACTUAL AIRFLOW SET IN SOFTWARE. 5.OCCUPIED SASH OPEN MODE: FUME HOOD EXHAUST AIR FLOW REPRESENTS A 80-100 FPM FACE VELOCITY AT 18-INCH SASH HEIGHT. FUME HOOD AIR VALVE BASIS OF DESIGN WILL BE 100 FPM @ 18-INCHES SASH HEIGHT. FINAL AIRFLOW SETPOINT ESTABLISHED DURING HOOD CERTIFICATION. 6.OCCUPIED SASH CLOSED MODE: CALCULATED BASED ON SPECIFIC HAZARD. 7.UNOCCUPIED SASH FULL MODE: FUME HOOD EXHAUST AIRFLOW REPRESENTS A 100 FPM FACE VELOCITY AT 18-INCH SASH HEIGHT, SASH IS ABOVE 18-INCHES. FUME HOOD EXHAUST SHALL NOT INDEX TO UNOCCUPIED MODE. 8.UNOCCUPIED SASH OPEN MODE: FUME HOOD EXHAUST REPRESENTS AT 65 FPM FACE VELOCITY, SASH IS AT OR BELOW 18-INCHES. FUME HOOD EXHAUST SHALL INDEX TO UNOCCUPIED MODE. 9.UNOCCUPIED SASH CLOSED MODE: CALCULATED BASED ON SPECIFIC HAZARD. DROPS BELOW TEMPERATURE, THE EXHAUST AIR VALVE SHALL CLOSE. IS THE DUCT TEMPERATURE EXCEEDS 90 DEG F. ONCE THE TEMPERATURE SENSOR SHALL COMMAND THE EXHAUST AIR VALVE TO MAXIMUM AIRFLOW FOR ALL OCCUPANCY MODES, THE CANOPY EXHAUST DUCT TEMPERATURE SCHEDULEPOINT EQUIPMENT POINTSHARDWARE POINTSSOFTWARE GRAPHIC ON SHOWN NOTES BI BO AI AO AV BV SCH TREND ALARM BACS EMCS DESCRIPTION (CFM) AIRFLOW EXHAUSTTOTAL X X X (CFM) SETPOINT EXHAUSTTOTAL X X X (ACPH) RATE CHANGE AIRLAB X X X FT) (SQ AREAROOM X X (FT) HEIGHTCEILING X X (CFM) SETPOINT OFFSETFLOW X X (CFM) ACTUAL OFFSETFLOW X X (CFM) FEEDBACK AIRFLOW VALVE AIR EXHAUST HOODFUME X X X STATUS VALVE AIR EXHAUST HOODFUME X X FEEDBACK TO EQUAL NOT COMMANDVALVE X ALARMTRI-STATE X SWITCH) (VIA PRESSURE DIFFERENTIALLOW POSITION SASH HOODFUME X X X MORE OR HOURS CONTINUOUS 24 FOR (18') OPENSASH X COMMAND UNOCC / OCC VALVE AIR EXHAUST HOODFUME X X POINT OUTPUTTRI-STATE STATUS VALVE AIR EXHAUST HOODCANOPY X X XX X COMMAND POSITION VALVE AIR EXHAUST HOODCANOPY X X X (CFM) SETPOINT AIRFLOW MIN VALVE AIR EXHAUST HOODCANOPY X X (CFM) SETPOINT AIRFLOW MAX VALVE AIR EXHAUST HOODCANOPY X X TEMPERATURE DUCTEXHAUST X X X SENSOR POINTSINGLE STATUS VALVESUPPLY X X SETPOINT FROM DEVIATION FLOW10% X ALARMTRI-STATEX FEEDBACK TO EQUAL NOT COMMANDVALVE X SWITCH) (VIA PRESSURE DIFFERENTIALLOW COMMAND POSITION VALVESUPPLY X X X (CFM) SETPOINT AIRFLOW MIN VALVESUPPLY X X (CFM) SETPOINT AIRFLOW MAX VALVESUPPLY X X COMMAND COIL REHEATELECTRIC X X X X SIGNAL 10V -0 TEMPERATURE AIR LEAVING COIL REHEATELECTRIC X X X SENSOR POINTSINGLE SENSORAIRFLOW X X X FLOWNO X HEATING SETPOINT, TEMPERATURESPACE X X X COOLING SETPOINT, TEMPERATURESPACE X X X TEMPERATURESPACE X X SETPOINT FROM F DEG 4 +/- TEMPERATURESPACE X PLANS TOREFER ADJUSTMENT SETPOINT TEMPERATURESPACE X X PLANS TOREFER OCCUPANCYSPACE X X X X PLANS TOREFER SETPOINT OCCUPANCY MINIMUM OCCUPANCY,SPACE X X X X PLANS TOREFER GDD 585 232 8300 | rochester@swbr.com These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR Architecture, Engineering & Landscape Architecture, D.P.C. and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR Architecture, Engineering & Landscape Architecture, D.P.C. All rights reserved. ©FILE PATH:Checked By: Project Manager: Drawn By: Revisions SWBR Project Number 20636.00 NEER NGENG SyracuseRochester 585.288.5590 Buffalo www.meengineering.com Mechanical/Electrical Engineering Consultants 300 TROLLEY BOULEVARD ROCHESTER, NY 14606 M/E Project #: 200278 Schenectady 387 East Main Street Rochester NY 14604 Cornell University Ithaca, NY Laboratory & Office Renovation Corson Hall Third Floor Documents 100% Construction March 5, 2021 CMD GDD M-205 1 N.T.S AIR SUPPLY MODCOM OR BACnet / MSTP: BACnet / ARCNET AI T AO- AV: FLOW SETPOINT (CFM) - AV: POSITION FEEDBACK (%) - AV: FLOW FEEDBACK (CFM) AO I H C SYSTEM DESCRIPTION GENERAL CONTROL SYSTEM (BACS). SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND ALL SETPOINTS SHALL BE ADJUSTABLE. SEVEN DIFFERENT DAILY SCHEDULES PER WEEK. THE BACS SHALL BE CAPABLE OF STARTING AND STOPPING THE SYSTEM FOR SETTING DURING A LOSS OF POWER FOR AT LEAST TEN HOURS. THE BACS SHALL BE CAPABLE OF RETAINING ITS PROGRAMMING AND TIME SETPOINTS SPACE COOLING TEMPERATURE SETPOINTS: OCCUPIED:7 8UNOCCUPIED: SPACE HEATING TEMPERATURE SETPOINTS: OCCUPIED:7 64UNOCCUPIED: SPACE OCCUPANCY SCHEDULE. ZONE OCCUPANCY SHALL BE DETERMINED BASED ON A TIME OF DAY ZONE TEMPERATURE CONTROL SCHEDULE. TEMPERATURE SETPOINTS SHALL BE DETERMINED BASED ON A PROGRAMMED ENABLED AS REQUIRED TO MAINTAIN SETPOINT. TEMPERATURE SETPOINT, THE ELECTRIC REHEAT COIL VALVE SHALL BE SETPOINT (MINIMUM). IF THE ZONE TEMPERATURE FALLS BELOW THE HEATING HEATING: THE SUPPLY AIR VAV BOX SHALL INDEX TO THE HEATING AIRFLOW REHEAT COIL SHALL BE DISABLED. AIRFLOW SETPOINTS AS NEEDED TO MAINTAIN SETPOINT. THE ELECTRIC MODULATE BETWEEN THE COOLING MINIMUM AND COOLING MAXIMUM COOLING TEMPERATURE SETPOINT, THE SUPPLY AIR VAV BOX SHALL AIRFLOW SETPOINT. IF THE ZONE TEMPERATURE RISES ABOVE THE OCCUPIED COOLING: THE SUPPLY AIR VAV BOX SHALL INDEX TO THE COOLING MINIMUM SEQUENCE OF OPERATION VARIABLE AIR VOLUME SUPPLY BOX W/ ELECTRIC REHEAT MOD COM OR BACnet / MSTP: BACnet / ARCNET AO - AV: FLOW SETPOINT (CFM) - AV: POSITION FEEDBACK (%) - AV: FLOW FEEDBACK (CFM) AIR EXHAUST HWSHWR F.L. N.O. AO WHERE SHOWN FIN TUBE RADIATION, ZONE INDICATES EXISTING BI OS sa d AI T SETPOINT AV REFER TO PLANS VARIABLE AIR VOLUME EXHAUST BOX PERIMETER FINTUBE RADIATION OFFICE E303 WITH AIR TERMINAL UNIT CONTROL AND PERIMETER FINTUBE RADIATION SCHEMATIC AND SYSTEM SUMMARY F AI Summaries System Control Schematics & EF SP AI SETPOINT AV ES BOO C BI MVFD F AI BYPASS MOD AO P BI AIR EXHAUST ES BI CIRCUIT TO FAN REFER TO PLANS SEQUENCE OF OPERATION SYSTEM DESCRIPTION BYPASS DAMPER GENERAL CONTROL SYSTEM (BACS). SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND ALL SETPOINTS SHALL BE ADJUSTABLE. SETTING DURING A LOSS OF POWER FOR AT LEAST TEN HOURS. THE BACS SHALL BE CAPABLE OF RETAINING ITS PROGRAMMING AND TIME SEVEN DIFFERENT DAILY SCHEDULES PER WEEK. THE BACS SHALL BE CAPABLE OF STARTING AND STOPPING THE SYSTEM FOR AND SHALL REQUIRE MANUAL RESET. ALL SAFETIES SHALL BE HARD WIRED INTO THE FAN MOTOR POWER CIRCUIT, SETPOINTS EXHAUST FAN SUCTION LOW STATIC PRESSURE LIMIT: -6.0" W.C. OWNER) SYSTEM OCUPANCY SCHEDULE: 6 AM - 8 PM, MON-FRI (COORDINATE WITH START/STOP SYSTEM SHALL BE ENABLED AT ALL TIMES. SHUTOFF DAMPER CONTROL EXHAUST AIR DAMPERS SHALL BE CLOSED. WHEN THE SYSTEM FANS ARE OFF, THE OUTSIDE AIR AND ASSOCIATED PRIOR TO STARTING THE SYSTEM FANS. ASSOCIATED EXHAUST AIR DAMPERS SHALL PROVE OPEN VIA END SWITCH WHEN THE SYSTEM FANS ARE INDEXED TO START, THE OUTSIDE AIR AND EXHAUST FAN SYSTEM CONTROL THE FAN SHALL MODULATE TO FULL OPERATING SPEED. DAMPER SHALL BE INDEXED TO OPEN. ONCE THE DAMPER IS PROVEN OPEN, MINIMUM START SPEED (20%), AT WHICH TIME THE ASSOCIATED FAN ISOLATION ON A CALL TO OPERATE, THE FAN SHALL BE INDEXED TO START AND RUN AT MODULATE CLOSED AS NEEDED TO MAINTAIN SETPOINT. RISES MORE POSITIVE THAN SETPOINT, THE BYPASS DAMPER SHALL MODULATE TO MAINTAIN SETPOINT. IF THE EXHAUST DUCT STATIC PRESSURE SETPOINT WITH THE FAN AT FULL SPEED, THE BYPASS DAMPER WILL OPEN AND IF THE EXHAUST DUCT STATIC PRESSURE FALLS MORE NEGATIVE THAN TO MAINTAIN THE CRITICAL ZONE DAMPER POSITION AT 95% OPEN. THE DOWNSTREAM STATIC PRESSURE SETPOINT SHALL BE RESET AS NEEDED CONTROL. THE FANS SHALL INDEX TO 40% OF FULL DESIGN FLOW. LABORATORY EXHAUST SYSTEM, THE SYSTEM SHALL INDEX AIRFLOW ON FAILURE OF THE MAKE-UP AIR HANDLING SYSTEM ASSOCIATED WITH THE SAFETIES OF THE LOW FAN SUCTION STATIC PRESSURE SWITCH. THE OUTSIDE AIR AND EXHAUST AIR DAMPERS SHALL CLOSE UPON ACTIVATION LOW FAN STATIC: THE SUPPLY AND EXHAUST AIR FANS SHALL SHUT DOWN, LABORATORY EXHAUST FAN EXHAUST FAN MINIMUM START SPEED: 20% OF MAX ASSOCIATED EXISTING AIR HANDLING UNIT. LABORATORY EXHAUST FAN SHALL BE INTERLOCKED WITH THE AIR HANDLING UNIT SYSTEM HARDWARE POINTS SOFTWARE POINTS GRAPHIC SHOWN ON NOTES BI BO AI AO AV BV SCH TREND ALARM BACS EMCS DESCRIPTION EXHAUST FAN ISOLATION DAMPER OPEN/CLOSED X X EXHAUST FAN ISOLATION DAMPER STATUS X X X EXHAUST FAN START/STOP X X X X INTERLOCK WITH FA SYSTEM EXHAUST FAN SPEED COMMAND X X X EXHAUST FAN STATUS X X X FAILURE X VIA CONTACT ON DRIVE EXHAUST FAN POWER (KW)X X X BACnet MSTP NETWORK POINT EXHAUST FAN SPEED (RPM)X X X BACnet MSTP NETWORK POINT EXHAUST FAN AIRFLOW (CFM)X X X MONITORING POINT ONLY EXHAUST FAN LOW SUCTION PRESSURE LIMIT X X X LOW LIMIT X BYPASS AIR DAMPER POSITION COMMAND X X BYPASS AIR DAMPER STATUS X X X EXHAUST FAN DOWNSTREAM STATIC PRESSURE X X X X 10% DEVIATION FROM SETPOINT X EXHAUST FAN DOWNSTREAM STATIC PRESSURE SETPOINT X X X POINT SCHEDULE 2 N.T.S LABORATORY EXHAUST FAN CONTROL SCHEMATIC AND SYSTEM SUMMARY SCHEDULEPOINT EQUIPMENT POINTSHARDWARE POINTSSOFTWARE GRAPHIC ONSHOW NOTES AV BV SCH TREND BI BO AI AO BACS EMCS DESCRIPTION SHED LOADSTEAM (6)X EMCS FROM INPUTS NETWRKBINARY SHED LOAD WATERCHILLED (4)X EMCS FROM INPUTS NETWRKBINARY COMMAND POSITION DAMPER BOX VAVSUPPLY X X X (CFM) FEEDBACK AIRFLOW BOX VAVSUPPLY X X X SETPOINT FROM DEVIATION FLOW10%X POINT NETWORK MSTPBACnet (CFM) SETPOINT AIRFLOW BOX VAVSUPPLY X X X POINT NETWORK MSTPBACnet (%) FEEDBACK POSITION BOX VAVSUPPLY X X X FEEDBACK TO EQUAL NOT COMMANDVALVE X POINT NETWORK MSTPBACnet COMMAND COIL REHEATELECTRIC X X X X SIGNAL 10V -0 TEMPERATURE AIR LEAVING COIL REHEATELECTRIC X X X SENSOR POINTSINGLE COMMAND POSITION VALVE RADIATION FINPERIMETER X X X LASTFAIL SENSORAIRFLOW X X FLOWNO X SETPOINT TEMPERATUREZONE X X X TEMPERATUREZONE X X X SETPOINT FROM F DEG 4 +/- TEMPERATURESPACE X PLANS TOREFER COMMAND POSITION DAMPER BOX VAVEXHAUST X X X (CFM) FEEDBACK AIRFLOW BOX VAVEXHAUST X X X X POINT NETWORK MSTPBACnet (CFM) SETPOINT AIRFLOW BOX VAVEXHAUST X X X POINT NETWORK MSTPBACnet (%) FEEDBACK POSITION BOX VAVEXHAUST X X X X POINT NETWORK MSTPBACnet OCCUPANCYSPACE X X X X PLANS TOREFER SETPOINT OCCUPANCY MINIMUM OCCUPANCY,SPACE X X X X PLANS TOREFER BO S S SCAO R BI TYPICAL VFD CONTROL/MONITORING POINTSVFDM R AOM SYSTEM FIRE ALARM WIRE TO COM BACnet / MSTP AV: SPEED (RPM) AV: POWER (KW) GDD 585 232 8300 | rochester@swbr.com These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR Architecture, Engineering & Landscape Architecture, D.P.C. and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR Architecture, Engineering & Landscape Architecture, D.P.C. All rights reserved. ©FILE PATH:Checked By: Project Manager: Drawn By: Revisions SWBR Project Number 20636.00 NEER NGENG SyracuseRochester 585.288.5590 Buffalo www.meengineering.com Mechanical/Electrical Engineering Consultants 300 TROLLEY BOULEVARD ROCHESTER, NY 14606 M/E Project #: 200278 Schenectady 387 East Main Street Rochester NY 14604 Cornell University Ithaca, NY Laboratory & Office Renovation Corson Hall Third Floor Documents 100% Construction March 5, 2021 MINIMUM 6'-0" FROM GRILLE 2" WIDE DUCT COLLAR. SHEETMETAL PLENUM SAME SIZE AS RETURN/ EXHAUST GRILLE NECK SIZE MINIMUM 6'-0" FROM GRILLE SHEETMETAL PLENUM SAME SIZE AS RETURN/ EXHAUST GRILLE NECK SIZE 2" WIDE DUCT COLLAR. RETURN/ EXHAUST GRILLE FACE RETURN/ EXHAUST GRILLE FACE TRANSITION ANGLE OF 30 DEG MAXIMUM.TRANSITION ANGLE OF 30 DEG MAXIMUM. RETURN/EXHAUST DUCTWORK INCREASE WIDTH OF DUCTWORK AS REQUIRED FOR CONNECTION OF FLEX CONNECTION TO DUCTWORK1" THICK INTERNAL SOUND LINING RETURN/ EXHAUST GRILLE NECK SHEETMETAL PLENUM SAME SIZE AS RETURN/ EXHAUST GRILLE NECK SIZE RETURN/EXHAUST DUCTWORK FLEX DUCT CONNECTION (SEE NOTE C) PLAN VIEW ELEVATION VIEW PLAN VIEW ELEVATION VIEW RETURN/EXHAUST DUCTWORK CEILING TYPE AS INDICATED ON ARCHITECTURAL DRAWING RETURN/ EXHAUST GRILLE FACE 12" MINIMUM DIMENSION FROM GRILLE FACE TO TOP OF PLENUM RETURN/EXHAUST DUCTWORK FLEX DUCT CONNECTION (SEE NOTE C) SHEETMETAL PLENUM SAME SIZE AS RETURN/ EXHAUST GRILLE NECK SIZE 12" MINIMUM DIMENSION FROM GRILLE FACE TO TOP OF PLENUM CEILING TYPE AS INDICATED ON ARCHITECTURAL DRAWINGS RETURN/ EXHAUST GRILLE FACE RETURN/ EXHAUST GRILLE NECK 1" THICK INTERNAL SOUND LINING PAINT INSIDE OF PLENUM BOX FLAT BLACK IF INTERNAL SOUND LINING IS NOT SPECIFIED. ALSO APPLICABLE TO REGISTERS. OMIT FLEX CONNECTION AND PROVIDE HARD CONNECTION TO GRILLES WHERE DUCTWORK IS EXPOSED OR WHERE DUCTWORK/GRILLE CONNECTION IS LOCATED ABOVE HARD CEILINGS. DO NOT PROVIDE FLEXIBLE DUCTWORK ABOVE HARD CEILINGS. DETAIL NOTES: A. B. C. FLOW RANGE (CFM)SIZE(IN.) 6" 8" 10" 12" 14" 16" 18" 20" 0-110 111-230 231-410 411-675 676-1000 1001-1400 1401-1950 1951-2500 MINIMUM FLEX DUCT DIAMETER MINIMUM 6'-0" FROM DIFFUSER SUPPLY AIR DUCT SUPPLY DIFFUSER MINIMUM 6'0" FROM DIFFUSER ALTERNATIVE #1 DECK, BEAM, OR JOIST NOTE: FLEX SHALL BE 4'-0" MAXIMUM WITH (1) 90 DEG BEND ELBOW SUPPORT FOR FLEX ALTERNATIVE #2 DUCT AND DIFFUSER SIZE AND TYPE AS SHOWN ON DRAWINGS. FLEX DUCT MAXIMUM LENGTH IS 24" WITH A 6" MAXIMUM OFFSET. OMIT FLEXIBLE DUCT CONNECTION AND PROVIDE HARD CONNECTION TO DIFFUSERS WHERE DUCTWORK/DIFFUSER CONNECTION IS LOCATED ABOVE HARD CEILINGS. DO NOT PROVIDE FLEXIBLE DUCTWORK ABOVE HARD CEILINGS. DETAIL NOTES: A. B. C. DETAIL NOTES: A. PROVIDE WIND RESTRAINT PER SPECIFICATION SECTION 230550-WIND RESTRAINT FOR HVAC SYSTEMS. ELECTRICAL JUNCTION BOX. LOCATE CONTROL RELAYS ADJACENT TO ELECTRICAL JUNCTION BOX. EXISTING ROOF DECK ROOF CURB CURB MOUNTING BRACKET BYPASS AIR PLENUM ISOLATION DAMPER EXHAUST FAN EXTENSION DRUM HIGH PLUME DISCHARGE NOZZLE 10'-0" MINDETAIL NOTES: A. REFER TO SCHEDULE FOR LENGTH, WIDTH AND HEIGHT OF THE CANOPY HOOD. B. DUCT CONNECTION TO HOOD SHALL MATCH SIZE OF EXHAUST DUCTWORK. REFER TO PLANS FOR DUCTWORK SIZE. CANOPY HOOD AND EXPOSED DUCTWORK SHALL BE CONSTRUCTED OF 304 STAINLESS STEEL, #3 POLISH FINISH, WELDED CONSTRUCTION DUCT CONNECTION SUPPORT CONNECTIONS (TYP.4) ROOF STRUCTURE LAY IN CEILING PROVIDE THREADED ROD FOR SUPPORT OF HOOD FROM ROOF STRUCTURE FUME HOOD FUME HOOD FUME HOOD WITH WORK SURFACE AT NON-ADA HEIGHT, 36" A.F.F. FUME HOOD WITH WORK SURFACE AT ADA HEIGHT, 30" A.F.F. DETAIL NOTES: 1 ROUND FLEXIBLE EXHAUST DUCT CONNECTION, SHOWING FULLY COMPRESSED TO ACCOMMODATE 36" WORK SURFACE HEIGHT. 2 ROUND FLEXIBLE EXHAUST DUCT CONNECTION, SHOWING FULLY EXTENDED TO ACCOMMODATE 30" WORK SURFACE HEIGHT. 3 FLEXIBLE EXHAUST DUCT SHALL BE FLEXAUST FLEX-LOK TCF, 12" ROUND NOMINAL DIMENSION, 5:1 COMPRESSION RATIO, SUITABLE FOR CHEMICAL FUME EXTRACTION. DUCT COLLAR (TYP.) LAB EXHAUST DUCT (TYP.) 2 31 3 These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions3/10/2021 4:10:11 PMC:\Users\sjgottlieb\Documents\200278_Corson3rdFloor_M_Central_R20_sjgottlieb.rvt20636.00 NMJ Details - HVAC GDD SJG M-300 100% Construction Documents Cornell University Corson Hall Third Floor Laboratory & Office Renovation Ithaca, NY March 5, 2021NOT TO SCALE1RETURN / EXHAUST GRILLE PLENUM DETAIL NOT TO SCALE2TYPICAL DIFFUSER INSTALLATION DETAIL NOT TO SCALE3ROOF MOUNTED FAN DETAIL NOT TO SCALE4CANOPY HOOD INSTALLATION DETAIL NOT TO SCALE5ADA FUME HOOD INSTALLATION DETAIL These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions3/10/2021 4:10:12 PMC:\Users\sjgottlieb\Documents\200278_Corson3rdFloor_M_Central_R20_sjgottlieb.rvt20636.00 NMJ Schedules - HVAC GDD SJG M-400 100% Construction Documents Cornell University Corson Hall Third Floor Laboratory & Office Renovation Ithaca, NY March 5, 2021 1 PROVIDE WITH HANGER BRACKETS REMARKS: EH-2 ACID WASH E334A 500 GREY PVC 9"5 24 36 4 @ 3/8" A KEES SLOTTED BACK SHELF HOOD EH-1 E304 800 304 SS 10" 33 60 18 - T-3 KEES INDUSTRAIL OVERHEAD HOOD 1 (IN.) (IN.) (IN.) UNIT NO. LOCATION CFM MATERIAL CONNECTION WIDTH LENGTH HEIGHT SLOTS STYLE MANUFACTURER & MODEL No. REMARKS EXHAUST HOOD SCHEDULE 2. PANEL SIZE = 24 IN X 24 IN 1. PANEL SIZE = 24 IN X 48 IN REMARKS: A EXHAUST STEEL WHITE TITUS MODEL 355-RL - 3 SUPPLY 304 SS WHITE TITUS MODEL TRITEC 2 2 SUPPLY STEEL WHITE TITUS MODEL TRITEC 2 1 SUPPLY STEEL WHITE TITUS MODEL TRITEC 1 TYPE APPLICATION MATERIAL FINISH MANUFACTURER & MODEL NO. REMARKS REGISTER GRILLE AND DIFFUSER SCHEDULE 3. SCR CONTROLLER. 2. INTEGRAL SOUND ATTENUATOR. 1. LINERS: FIBER FREE LINER. REMARKS: VAV-1 E303 120 90 0.01 5 10 22 1.0 90 55 90 120 1 10.4 15 TITUS DESV 1,2,3 (CFM) (CFM) (In. WC)(CFM) (DEG. F) (DEG. F) FLOW FLOW MAX CFM (In.)AIR FLOW TEMP. TEMP. AIR AIR PRESS AT SIZE AT 1" S.P. AT 1" S.P. (KW) HEATING ENT. AIR LVG. AIR VOLTS PHASE MCA MOP UNIT NO. SERVICE MAX MIN MIN INLET INLET RAD N.C. DISCH N.C. CAPACITY AIR SIDE ELEC. CHARACTERISTICS MANUFACTURER & MODEL NO. REMARKS VAV - SINGLE DUCT - AIR TERMINAL UNIT SCHEDULE - ELECTRIC REHEAT 8.MANUAL THERMAL CUTOUT 7.NEPTRONIC CONTROLLER 6.FULL BREAK CONTACTOR 5.DISCONNECT SWITCH 4.MAGNETIC CONTACTOR 3.AUTOMATIC THERMAL CUTOUT 2.ELECTRONIC AIRFLOW SENSOR 1.MODULATING SCR CONTROLLER REMARKS: ERHC-6 E334 OPEN LAB OPEN COIL FLANGED 7 - 630 55 90 12 12 208 3 19.4 INDEECO QUZ 1,2,3,4,5,6,7,8 ERHC-5 E334A ACID WASH HOOD OPEN COIL FLANGED 4.2 - 375 55 90 12 12 208 3 11.7 INDEECO QUZ 1,2,3,4,5,6,7,8 ERHC-4 E334B VESTIBULE OPEN COIL FLANGED 1.1 - 100 55 90 12 12 208 1 9.2 INDEECO QUZ 1,2,3,4,5,6,7,8 ERHC-3 E318 SOIL ROOM OPEN COIL FLANGED 3.9 - 350 55 90 12 12 208 3 10.8 INDEECO QUZ 1,2,3,4,5,6,7,8 ERHC-2 E305 OPEN COIL FLANGED 11.5 - 1030 55 90 .065 420 18 12 480 3 13.9 INDEECO QUZ 1,2,3,4,5,6,7,8 ERHC-1 E304 OPEN COIL FLANGED 1 - 90 55 90 .010 120 12 10 120 1 8.3 INDEECO QUZ 1,2,3,4,5,6,7,8 (CFM) (DEG. F) (DEG. F) (In. W.C.) (FPM) (In.) (In.) STEPS FLOW TEMP. TEMP. P.D. VELOCITY LENGTH WIDTH (KW) OF AIR ENT. AIR LVG. AIR AIR MIN. FACE VOLTS PHASE MCA UNIT NO.LOCATION TYPE MOUNTING CAPACITY NO. AIR SIDE COIL FACE...ELEC. CHARACTERISTCIS MANUFACTURER & MODEL No. REMARKS HEATING COIL SCHEDULE - ELECTRIC 8. SPECIAL COATING - HI-PRO-Z 7. SPARK RESISTANT 6. ADJUSTABLE SPEED DRIVE 5. WEATHER COVER 4. ACCESS DOOR 3. DISCHARGE NOZZLE 2. ISOLATION DAMPER 1. BYPASS DAMPER REMARKS: LEF-1 ROOF E334A ACID WASH TUBULAR CENTRIFUGAL BI 1.0 125 500 500 3,670 16.7 0.27 2487 79 DIRECT 3500 3/4 480 60 3 ASD GREENHECK VEKTOR-H-10 1,2,3,4,5,6,7,8 (CFM) (CFM) FLOW (CFM) (FPM) HEIGHT (Ft.-In.)SOUND (LWA) TYPE (In. WC) FLOW FLOW DISCHARGE VELOCITY EFFECTIVE BHP RPM DISCHARGE TYPE BLADE S.P. MIN INLET MAX INLET TOTAL NOZZLE DISCHARGE MAX. FAN MAX. DRIVE FEG RPM HP VOLTS HZ PHASE STARTER UNIT NO. LOCATION SERVICE FAN CHARACTERISTICS MIN. MOTOR CHARACTERISTICS MANUFACTURER & MODEL NO. REMARKS FAN SCHEDULE - LABORATORY EXHAUST 7. UNIT SHALL FAIL OPEN. 6. PROVIDE WITH TIGHT SHUT-OFF. 5 PROVIDE WITH FACTORY DRAW BAND CLAMPS IF VENTURI STYLE VALVE IS PROVIDED. 4. PROVIDE WITH FAN STATIC RESET IF VENTURI STYLE VALVE IS PROVIDED. 3. PROVIDE WITH FACTORY SOUND NEUTRALIZER IF VENTURI STYLE VALVE IS PROVIDED. 2. THE MAX / MIN POSITIONS ON THE VALVE WILL BE SET AT THE FACTORY TO THE FULL RANGE WITH ACTUAL SETPOINTS IN SOFTWARE 1. REFER TO THE LAB AIRFLOW SCHEDULES FOR FURTHER REQUIREMENTS. REMARKS: GEV-4 E334 E334 OPEN LAB 8 0 800 0 140 HORIZONTAL 0.2 ACCUTROL ACCUVALVE AVC6000 1,2,3,4,5,6,7 GEV-3 E334 E318 CANOPY HOOD 8 0 800 500 500 HORIZONTAL 0.2 ACCUTROL ACCUVALVE AVC6000 1,2,3,4,5,6,7 GEV-2 E305 E305 10 0 1300 190 600 HORIZONTAL 0.2 ACCUTROL ACCUVALVE AVC6000 1,2,3,4,5,6,7 GEV-1 E304 CANOPY HOOD 8 0 800 500 500 HORIZONTAL 0.2 ACCUTROL ACCUVALVE AVC6000 1,2,3,4,5,6,7 FEV-3 E334 E334 FUME HOOD 10 0 1300 280 630 HORIZONTAL 0.2 ACCUTROL ACCUVALVE AVC6000 1,2,3,4,5,6,7 FEV-2 E334 E334A ACID WASH HOOD 8 0 1300 125 500 HORIZONTAL 0.2 ACCUTROL ACCUVALVE AVC6000 1,2,3,4,5,6,7 FEV-1 E304 FUME HOOD 10 0 1300 280 630 HORIZONTAL 0.2 ACCUTROL ACCUVALVE AVC6000 1,2,3,4,5,6,7 SAV-6 E334 E334 OPEN LAB 10 0 1300 280 630 HORIZONTAL 0.2 ACCUTROL ACCUVALVE AVC6000 1,2,3,4,5,6,7 SAV-5 E334A E334A ACID WASH HOOD 8 0 800 0 375 HORIZONTAL 0.2 ACCUTROL ACCUVALVE AVC6000 1,2,3,4,5,6,7 SAV-4 E334B E334B VESTIBULE 8 0 800 100 100 HORIZONTAL 0.2 ACCUTROL ACCUVALVE AVC6000 1,2,3,4,5,6,7 SAV-3 E318 E318 SOIL ROOM 8 0 800 0 350 HORIZONTAL 0.2 ACCUTROL ACCUVALVE AVC6000 1,2,3,4,5,6,7 SAV-2 E305 E305 8 0 800 90 500 HORIZONTAL 0.2 ACCUTROL ACCUVALVE AVC6000 1,2,3,4,5,6,7 SAV-1 E304 E304 12 0 1790 180 1030 HORIZONTAL 0.2 ACCUTROL ACCUVALVE AVC6000 1,2,3,4,5,6,7 (CFM) (CFM) (CFM) (CFM)(In. WC.) FLOW FLOW FLOW FLOW PRESSURE (In.) MIN AIR MAX AIR MIN AIR MAX AIR POSITION OPERATING UNIT NO. LOCATION SERVICE SIZE FACTORY RANGE OPERATIONAL RANGE MOUNTING MINIMUM MANUFACTURER & MODEL NO.REMARKS LAB AIR VALVE SCHEDULE BASIC MATERIALS AND METHODS 3 HEAVY SOLID IS NEW, EXISTING ELECTRICAL WIRING, EQUIPMENT OR DEVICE, SOLID LIGHT IS EXISTING TO REMAIN , EXISTING ELECTRICAL WIRING, EQUIPMENT OR DEVICE, DASED LIGHT IS EXISTING TO BE REMOVED OR RELOCATED , REFERENCE TO DRAWING NOTE OS J TOGGLE SWITCH, VOLTAGE AS INDICATED ON FIXTURE SCHEDULE, SUBSCRIPTS INDICATE TYPE: 2 - TWO POLE SWITCH 3 - THREE WAY SWITCH 4 - FOUR WAY SWITCH M - MONENTARY CONTACT K - KEY OPERATED a,b,c - SWITCHING DESIGNATIONS NUMBER OF LETTERS EQUALS NO. OF GANGED SWITCHES V - VACANCY SENSOR VD - VACANCY SENSOR, DIMMER SWITCH VDS - VACANCY SENSOR, DUAL SWITCHED WP - WEATHERPROOF QUAD RECEPTACLE 20 AMP, 125 VOLT DUPLEX RECEPTACLE, 20 AMP, 125 VOLT SUBSCRIPTS INDICATE TYPE: G - GROUND FAULT INTERUPT OC - OVER COUNTER UC - UNDER THE COUNTER WP - WEATHER PROOF TP - TAMPER PROOF P - CEILING PROJECTOR, MOUNT IN PROJECTOR MOUNTING PLATE USB - INTEGRAL USB CHARGER H - MOUNT IN HORIZONTAL DIRECTION SPECIAL PURPOSE RECEPTACLE. PROVIDE PROPER VOLTAGE, CLASS, CURRENT RATING AND NEMA CONFIGURATION AS REQUIRED BY BRANCH CIRCUIT AND/OR MATCH CAP ON EQUIPMENT BEING FURNISHED BY OTHERS. PROVIDE CORD AND CAP. SUBSCRIPTS INDICATE TYPE: J CEILING MOUNTED OCCUPANCY SENSOR JUNCTION BOX 3a,b,c 3 REFERENCE TO DEMOLITION NOTE EXISTING TO REMAIN - INDICATES EXISTING ITEM SHALL REMAIN. MAINTAIN EXISTING ELECTRICAL CONNECTIONS UNLESS OTHERWISE NOTED. (E) EXISTING TO BE RELOCATED - INDICATES EXISTING ITEM SHALL BE RELOCATED. DISCONNECT AND REMOVE, REINSTALL AT NEW LOCATION AND RECONNECT ITEM AS REQUIRED. (ER) PUSH BUTTON COMMUNICATIONS EXISTING COMMUNICATIONS OUTLET TEL/DATA DROP: 4"x4"x2.50" BOX WITH A 1-GANG MUD RING & FACEPLATE WITH DUPLEX DESIGN. 1" CONDUIT EXTENDED TO NEAREST CABLE TRAY IN CORRIDOR ( UNLESS OTHERWISE NOTED) FOR DATA/VOICE. TERMINATE CONDUIT AT CABLE TRAY IN CORRIDOR WITH CONDUIT BUSHING. PULL (2) CAT 6 CABLE, TERMINATE AT PATCH PANEL IN BDF. W - SINGLE GANG BACK BOX WITH MUD RING AND 1" CONDUIT EXTENDED TO NEAREST CABLE TRAY IN CORRIDOR (UNLESS OTHERWISE NOTED) FOR DATA/VOICE. WALL MOUNT AT 46"AFF. PROVIDE (1) CAT 6 CABLE TO BDF. DDC - SINGLE GANG BOX WITH BLANK COVER PLATE. PROVIDE 3/4"C STUBBED TO ACCESSIBLE CEILING SPACE ABOVE. DDC ALARM WIRING BY DIV 23. C - CAMERA, COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL DRAWINGS. TV - COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL DRAWINGS. DSR DSS FSD FS TS FAAP FACP WAP H F F F SD S FIRE ALARM SMOKE DAMPER CONNECTION DUCT SMOKE DETECTOR, RETURN SIDE DUCT SMOKE DETECTOR, SUPPLY SIDE FIRE ALARM SHUT DOWN RELAY FLOW SWITCH CONNECTION TAMPER SWITCH CONNECTION FIRE ALARM ANNUNCIATION PANEL FIRE ALARM CONTROL PANEL REMOTE DUCT SMOKE DETECTOR TEST INDICATOR RATE-OF-RISE HEAT DETECTOR ALARM SIGNAL, STROBE, SHALL BE WHITE DEVICE ALARM SIGNAL, SPEAKER AND STROBE, SHALL BE WHITE DEVICE MANUAL PULL STATION SMOKE DETECTOR M D CB T CONTACTOR ENCLOSED CIRCUIT BREAKER COMBINATION FUSED DISCONNECT SWITCH AND MAGNETIC STARTER 208Y/120 VOLT PANELBOARD. TRANSFORMER COMPLETE ELECTRICAL CONNECTION TO EQUIPMENT A d A d CEILING MOUNTED EXIT LUMINAIRE WALL MOUNTED EXIT LUMINAIRE STRIP LUMINAIRE CEILING MOUNTED AREA-OF-RESCUE LUMINAIRE WALL MOUNTED AREA-OF-RESCUE LUMINAIRE CEILING MOUNTED LUMINARIE. UPPERCASE LETTERS INDICATE FIXTURE TYPE ON LUMINAIRE SCHEDULE, LOWER CASE LETTER INDICATE LIGHTING ZONE WALL MOUNTED LUMINARIE. UPPERCASE LETTERS INDICATE FIXTURE TYPE ON LUMINAIRE SCHEDULE, LOWER CASE LETTER INDICATE LIGHTING ZONE LUMINAIRE CONNECTED TO LIFE SAFETY EMERGENCY POWER WALL MOUNTED EMERGENCY LUMINAIRE WITH BATTERY PACK MOTOR CONNECTION. REFER TO ELECTRICAL EQUIPMENT AND CONTROL SCHEDULE FOR SIZE POWER DISTRIBUTION AND CONTROL 480Y/277 VOLT PANELBOARD. DISCONNECT SWITCH FUSED DISCONNECT SWITCH DISTRIBUTION PANELBOARD. MOTORIZED DAMPER CONNECTION LUMINAIRES TRACK LIGHTING DOUBLE HEAD POLE MOUNTED LUMINAIRE SINGLE HEAD POLE MOUNTED LUMINAIRE CEILING RECEPTACLE 4'-0" EXIT LIGHT SWITCH 2. MOUNTING HEIGHTS TO CENTER OF OUTLETS UNLESS OTHERWISE NOTED. IN MASONRY CONSTRUCTION THE ABOVE MOUNTING HEIGHTS SHALL BE USED FOR REFERENCE TO NEAREST BLOCK OR BRICK COURSING. THE ABOVE MOUNTING HEIGHTS SHALL BE ADHERED TO UNLESS SPECIFICALLY NOTED OR DETAILED OTHERWISE ON THE DRAWINGS. 1. DETAIL NOTES: 1'-6" DIVIDED SURFACE RACEWA Y HORN/LIGHT LENS ON TOP FINISHED FLOOR PULLSTATION COORDINATE EXACT MOUNTING HEIGHT WITH ARCHITECT. ENTIRE LENS SHALL BE MINIMUM 80" AFF AND NOT GREATER THAN 96" AFF. WHERE NOT PERMITTED BY CEILING HEIGHT DEVICE SHALL BE MOUNTED WITHIN 6" OF THE CEILING. 4'-0" EXIT SIGNS CENTERED ABOVE DOOR CR CARD READER, REFER TO DETAIL DC DOOR CONTACT COMBINATION POWER/COMMUNICATION SURFACE RACEWAY WITH DEVICES AS INDICATED. WIREMOLD G4000. RACEWAY SHALL BE MOUNTED "OVER COUNTER" UNLESS OTHERWISE NOTED. VS CEILING MOUNTED VACANCY SENSOR. WAP - WIRELESS ACCESS POINT WALL MOUNT AT 90"AFF 4"x4"x2.25" BOX WITH DOUBLE GANG PLASTER RING. 1" EMT CONDUIT EXTENDED TO NEAREST CABLE TRAY IN CORRIDOR (UNLESS OTHERWISE NOTED). PROVIDE TWO (2) CAT 6A CABLES. TERMINATE IN BDF AND 6-8" PIGTAIL WITHOUT FACEPLATE. All WAP ARE WALL MOUNTED. REFER TO ARROWS ON DRAWINGS FOR LOCATION. EM TYPICAL EMERGENCY PHONE OUTLET LOCATION. PROVIDE 4"x4" BACKBOX WITH A SINGLE GANG MUD RING AND (1) 3/4" CONDUIT TO ACCESSIBLE CEILING SPACE. PROVIDE (1) CAT 6 CABLE TO BDF. COORDINATE FINAL LOCATION WITH THE OWNER PRIOR TO INSTALLATION. RTS ENCLOSED CABLE TRAY SIZE PER QUANTITY OF CABLES AND 50% FUTURE CAPACITY AT A MINIMUM. POWER AND DATA PULLBOX IN CEILING LP-10,# HOME RUN TO PANELBOARD. LETTERS/ NUMBERS INDICATE PANEL. NUMBERS INDICATE CIRCUITS. NUMBER OF ARROWS EQUALS NUMBER OF CIRCUITS. CIRCUIT SHALL BE 2-#12, 1#12EG FROM 20A-1P CIRCUIT BREAKER, UNLESS NOTED OTHERWISE. BRANCH CIRCUIT WIRING SIZE AND NUMBER TO MATCH HOMERUN. REFER TO SPEC'S FOR RACEWAY TYPE. SOLID HALF ARROW(S) INDICATES 120 VOLT CIRCUIT TO SINGLE POLE CIRCUIT BREAKER(S), UNLESS NOTED OTHERWISE. SOLID FULL ARROW(S) INDICATES 208 VOLT CIRCUIT TO MULTI-POLE CIRCUIT BREAKER(S), UNLESS NOTED OTHERWISE. GFCI DUPLEX RECEPTACLE, 20 AMP, 125 VOLT G. H. I. WHEN EXISTING CONSTRUCTION, WHICH IS TO REMAIN, IS DAMAGED DURING THE COURSE OF DEMOLITION AS A RESULT OF THE CONTRACTOR'S WORK, IT SHALL BE REPAIRED AND/OR REPLACED WITH SIMILAR OR LIKE MATERIALS, AS MUCH AS POSSIBLE, SUBJECT TO THE OWNERS APPROVAL. THE CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND REPLACEMENT OF EXISTING CONSTRUCTION IN THE WAY OF NEW WORK. PROTECT BUILDING AND FURNISHINGS FROM DAMAGE. COORDINATE PHASING OF WORK WITH OWNER'S REPRESENTATIVE. COORDINATE ALL SHUTDOWNS WITH UNIVERSITY PRIOR TO DEMOLITION. ALL FIRE ALARM SHUTDOWNS SHALL BE SCHEDULED THROUGH CUSTOMER SERVICE WITH AT LEAST 24 HOURS NOTICE BEFORE WORK IS TO BE STARTED. EXISTING CONDITIONS ARE TAKEN FROM FIELD OBSERVATIONS AND PRIOR CONSTRUCTION DOCUMENTS WHEN AVAILABLE AND ARE NOT GARAUNTEED. PRIOR TO SUBMITTING BID, VISIT SITE AND IDENTIFY EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT THE DEMOLITION WORK. NO COMPENSATION WILL BE GRANTED FOR ADDITIONAL WORK CAUSED BY UNFAMILIARITY WITH SITE CONDITIONS THAT ARE VISIBLE OR READILY CONSTRUED BY EXPERIENCED OBSERVERS. THIS CONTRACTOR SHALL PARTICIPATE IN SURVEY OF THE EXISTING ELECTRICAL SYSTEMS. THE CONTRACTOR SHALL DISCONNECT AND CAP ALL SERVICE LINES TO BE DISCONNECTED FOR THOSE SERVICES WHICH NORMALLY ARE INCLUDED IN HIS FIELD OF WORK. PARTICULAR CARE SHALL BE TAKEN TO AVOID CREATING HAZARD OR CAUSING DISRUPTION IN ADJOINING AREAS. NOT ALL DEVICES TERMINATIONS, JUNCTION BOXES AND WIRING HAVE BEEN SHOWN. REFER TO PLUMBING CONTRACT DRAWINGS AND SPECIFICATIONS FOR EXACT QUANTITIES AND LOCATIONS OF ALL PLUMBING EQUIPMENT BEING ABANDONED OR REMOVED, WHICH WILL REQUIRE DE-ENERGIZATION, REMOVAL AND BLANK-OFF BY THE CONTRACTOR. EXISTING FIRE ALARM SYSTEM SHALL BE KEPT OPERATIONAL DURING THE CONSTRUCTION PERIOD THE BUILDING UNDER RENOVATION MAY BE DISCONNECTED FROM SERVICE DURING THE HOURS THE CONTRACTOR IS WORKING, AT THE DISCRETION OF THE FIRE DEPARTMENT AND THE OWNER'S REPRESENTATIVE, BUT MUST BE OKACED BACK ON LINE DURING OTHER PERIODS. APPROVAL TO BE IN WRITING. THE EXISTING ELECTRICAL EQUIPMENT AND DEVICES WITHIN DEMOLITION AREA SHALL BE DEMOLISHED ALONG WITH ALL FEEDERS AND CONDUITS BACK TO POINT OF SOURCE UNLESS OTHERWISE NOTED. ALL ITEMS SHOWN ON THE DEMOLITION DRAWINGS SHALL BE DISCONNECTED AND REMOVED UNLESS NOTED OTHERWISE. WALLBOXES, BACKBOXES AND CONDUIT SHALL BE REUSED AS DETERMINED BY CONTRACTOR. ALL UNUSED CONDUITS SHALL BE REMOVED. DISCONNECT AND MAKE SAFE ANY EQUIPMENT TO BE REMOVED BY OTHERS. COORDINATE REMOVAL OF EQUIPMENT WITH OTHER TRADES PRIOR TO DEMOLITION. MAINTAIN AND RESTORE, IF INTERRUPTED BY REMOVALS OR IN PATH OF NEW CONSTRUCTION, ALL CIRCUITS, CONDUITS AND FEEDERS PASSING THROUGH AND SERVING UNDISTURBED AREAS (SHOWN OR NOT SHOWN). ALL EXISTING CONDUITS STUBBED THROUGH FLOOR SERVING ITEMS TO BE REMOVED AND NOT SHOWN OR REQUIRED TO BE REUSED, SHALL BE CUT OFF FLUSH WITH SLAB LEVEL WITH CONCRETE. IN ANY AREA REQUIRING THE PERFORMANCE OF ANY TRADE'S WORK WORK, THIS CONTRACTOR SHALL CAREFULLY REMOVE AND STORE ANY OR ALL ELECTRICAL ITEMS IN PATH OF WORK, REINSTALLING AND RECONNECTING SAME AS REQUIRED, IN ACCORDANCE WITH THE PLANS AND/OR AS DIRECTED AFTER COMPLETION OF OTHER TRADE'S WORK IN THAT AREA. DISCONNECT, MAKE SAFE AND REMOVE ALL TEMPORARY AND ABANDONED WIRE WITHIN THE SPACE. BRANCH CIRCUIT WIRING TO DEVICES IN AREAS OF DEMOLITION SHALL BE DISCONNECTED, MADE SAFE AND REMOVED COMPLETELY BACK TO THE PANELBOARD. THE CONTRATOR SHALL NOT ABANDON BRANCH CIRCUIT WIRING TO ANY AREAS WICH ARE TO REMAIN BUT ARE AFFECTED BY THE DEMOLITION OR NEW CONSTRUCTION. DISCONNECT AND REMOVE PANEL, FEEDERS AND BRANCH CIRCUITS BACK TO POINT OF SOURCE PRIOR TO THE START OF DEMOLITION, CONTRACTOR SHALL FIELD VERIFY ALL BRANCH CIRCUITS AND MAINTAIN THOSE CIRCUITS THAT EXTEND OUTSIDE OF THE SCOPE OF WORK. AFTER RENOVATING EXISTING ELECTRICAL WORK, THE CONTRACTOR SHALL INSURE THAT ALL REMAINING AND NEW EQUIPMENT WILL OPERATE PROPERLY. PROVIDE TEMPORARY HEAT DETECTORS IN AREAS WHERE SPRINKLERS ARE REMOVED FROM SERVICE DURING CONSTRUCTION. COORDINATE WITH FIRE PROTECTION CONTRACTOR. REFER TO MACHANICAL CONTRACT DRAWINGS AND SPECIFICATIONS FOR EXACT QUANTITIES AND LOCATIONS OF ALL MECHANICAL EQUIPMENT BEING ABANDONED OR REMOVED, WHICH WILL REQUIRE DE-ENERGIZATION, REMOVAL AND BLANK-OFF BY THE CONTRACTOR. GENERAL DEMOLITION NOTES:(APPLY TO ALL DRAWINGS): A. B. C. D. E. F. G. H. I. SLEEVE AND SEAL ALL WALL AND FLOOR PENETRATIONS. PROVIDE FIRESTOPPING FOR ALL FIRE-RATED PENETRATIONS. UTILIZE REMOVABLE FIRESTOPPING MATERIAL AT CABLE TRAY PENETRATIONS. PROVIDE ACOUSTICAL SEALANT FOR ALL NON RATED PENETRATIONS. ALL FIRE RATINGS SHALL BE MAINTAINED. MAINTAIN SERVICE CLEARANCES OF ALL EQUIPMENT. COORDINATE EXACT LOCATION OF ALL CONDUIT ROUTES, EQUIPMENT AND DEVICES WITH EXISTING CONDITIONS PRIOR TO CONSTRUCTION. MINIMUM CONDUIT SIZE SHALL BE 3/4" FOR POWER CIRCUITS UOI. PROVIDE NYLON PULLSTRING IN ALL EMPTY CONDUITS. FIRE ALARM SIGNALING APPLIANCES SHALL BE MOUNTED SUCH THAT THE ENTIRE LENS IS NOT LESS THAN 80 INCHES AND NOT GREATER THAN 96 INCHES ABOVE THE FINISHED FLOOR. CIRCUITING TO DEVICES/EQUIPMENT SHALL BE 2-#12AWG & 1-#12EG (MULTIPLE HOME RUNS IN SAME CONDUIT MAY SHARE SAME EQUIPMENT GROUND) FOR EACH 20 AMPERE CIRCUIT UNLESS OTHERWISE NOTED. ALL CIRCUITS SHALL HAVE SEPARATE NEUTRALS (CIRCUITS SHALL NOT SHARE NEUTRALS). PROVIDE CONDUIT/WIRING (CIRCUITING) AND REQUIRED EQUIPMENT CONNECTIONS TO ALL DEVICES/EQUIPMENT. CONNECT TO CIRCUIT(S) AS INDICATED. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE REFERENCE STANDARD EDITION OF NFPA CODES, AS CITED BY THE FIRE CODE OF NEW YORK STATE, BUILDING CODE OF NEW YORK STATE AND CORNELL UNIVERSITY DESIGN STANDARDS. ALL CONDUITS AND SUPPORTS SHALL BE AS TIGHT TO DECK AS POSSIBLE. PROVIDE PULLBOX FOR EVERY 180 DEGREE OF BENDS FOR TEL/DATA AND 360 DEGREES OF BENDS FOR POWER CONDUITS. ALL ELECTRICAL DEVICES (RECEPTACLES, SWITCHES, FIRE ALARM, ETC.) SHALL BE ALIGNED HORIZONTALLY AND VERTICALLY. CONTRACTOR TO SCHEDULE AND COORDINATE PROJJECT WALKTHROUGH WITH ARCHITECT AND ENGINEER PRIOR TO COMMENCEMENT OF ANY DEVICE ROUGH-IN FOR FINALIZATION OF ALIGNMENTS. REFER TO EAV SERIES DRAWINGS FOR ADDITIONAL ELECTRICAL WORK. ALL EXISTING DEVICES CIRCUITED TO PANELS BEING RENAMED SHALL BE PROVIDED WITH UPDATED LABELS. PROVIDE ALL PATHWAYS AND BACK BOXES AS CALLED FOR ON AV DRAWINGS PROVIDED BY ANOTHER CONSULTANT. COORDINATE IT SERVICE CHANGES OR DISRUPTIONS IN SERVICE WITH CIT OPERATIONS AT 255-5500. ALL RECEPTACLES WITHIN 6' OF SINK EDGE SHALL BE GFCI TYPE. GENERAL NOTES:(APPLY TO ALL DRAWINGS): A. B. C. D. E. F. J. K. L. M. N. J. K. L. M. N. FCU FAN COIL UNIT FIRE ALARM CONTROL PANEL FIRE ALARM TERMINAL CABINET CONT.CONTACTOR F.A.T.C. F.A.C.P. ELECTRIC WATER COOLER DISTRIBUTION PANEL GROUND FAULT CIRCUIT INTERRUPTER GENERAL CONTRACTOR ELECTRICAL CONTRACTOR HEATING, VENTILATING AND AIR CONDITIONING F.A.FIRE ALARM H.V.A.C. G.C. E.C. BSMT.BASEMENT CLG. EA. CONTR. GEN. CEILING EACH GENERATOR A.AMPERE DN. EXIST. AUTO. DOWN EXISTING AUTOMATIC DP EMERG. ELEC. G.F.C.I. ELECTRIC EMERGENCY HORSEPOWER GALVANIZED RIGID STEEL GND.GROUND GRS. ABBREV. ABBREVIATIONS C BKR. HP. CAMERA BREAKER DESCRIPTION FZ (3)FIRE ZONE (3) ABOVE FINISHED FLOORA.F.F. EM.EMERGENCY CONTRACTOR A.F.G.ABOVE FINISHED GRADE EWC MOUNTED UNDER COUNTER HEIGHT TV TELEVISION WEATHERPROOF REFRIGERATOR SPECIFICATION MOUNTED OVER COUNTER HEIGHT PLUMBING CONTRACTOR TELEPHONE BACKBOARD TELEPHONE TERMINAL CABINET T.B.B. MICRO T.T.C. MICROWAVE P.C. REFRIG. TYP.TYPICAL SPEC. P. SP.SPACE POLE NL NIGHT LIGHT V.VOLT SW. SWITCH MAIN CIRCUIT BREAKER MAIN LUG ONLY P = POLE A = AMPERE UNDERWRITER'S LABORATORY LTG. U.L. 4 W. KW. LIGHTING KILOWATT WIRE M.L.O. 3P.15A. PH. M.C.B. PHASE PNL.PANEL PV POWER VENTILATOR WP OC UC UV WG VP EF EHP CUH UNIT VENTILATOR WIRE GUARD FRACTIONAL HORSEPOWER EXHAUST FAN CABINET UNIT HEATER VANDAL PROOF POLYCARBONATE GUARD ABBREVIATIONS ABBREV. DESCRIPTION WAP WIRELESS ACCESS POINT O. UH UNIT HEATER P. O. P. Q. AAD AUTOMATIC AIR DAMPER Q. These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions3/10/2021 12:06:44 PMC:\Users\crspall\Documents\200278_Corson3rdFloor_E_Central_R20_crspall.rvt20636.00 MRG Symbols List & General Notes - Electrical GDD CRS E-000 100% Construction Documents Cornell University Corson Hall Third Floor Laboratory & Office Renovation Ithaca, NY March 5,2021 E344C E331 E300SB E300C A300C A300UE A300UF A305 A306 A300TB A300UG A300S OPEN TO BELOW E301 E310 E340 E344A E344 E344B E320 E309B DN DN DN UP S S F F F F WAP WAP S S S S S M M M M J J DSD RTS SD F WAPS F S J M F F S S M WAP WAP WAP DSD RTS SD DSD RTS SD DSD RTS SD J J E344C E331 E300SB E300C A306 A300TB A300UG E301 E310 E340 E344A E344 E344B E320 E309B DN DN UP WAP WAPA C D F H 11 12 13 14 15 16 17 18 FACULTY OFFICE E303 LAB E305 LAB E304 DARK ROOM E304B Room E304A Room E306 OFFICE E321 COMPUTATIONAL LAB E323 Room E325 OPEN LAB E334 ACID WASH E334A VEST E334B SOIL ROOM E318 Room E309A Room E309 OFFICE 311 KITCHENETTE 317C CONFERENCE 317B OPEN OFFICE 317 FACULTY OFFICE 317A FACULTY OFFICE 315 PLE3-9(E)GFI WP F' G' GFI (E)(E) (E)(E) GFI GFI EPLE3-2(E) EPLE3-3(E) 2 3 EXISTING TEL/DATA CLOSET ERHC-3 ERHC-4 ERHC-5 ERHC-6 LAB AIR VALVE LAB AIR VALVE (E) (E) (E) (E) (E) (E) DPLE3-1(E) EPLE3-1(E) ELHE3-1(E) LHE3-1(E) DPHE3-1(E) PLE3-6(E) PLE3-10(E) DPLE3-3(E)PLE3-8(E) VAV-1 PLE3-1(E) PLE3-1(E), 10 ERHC-1 PLE3-1(E), 8 PLE3-6(E), 14,16 PLE3-8(E), 17 PLE3-8(E), 19 EPLE3-1(E), 17 EPLE3-1(E), 15 (E) ERHC-2 LHE3-1 10,12,14 EPLE3-3(E), 8 4 5 3 5 7 2 6 12 12 12 15 15 15 15 15 1717 1720 19 19 19 19 19 21 21 21 21 21 23 23 23 23 23 25 25 25 25 254 4 4 4 4 PLE3-5(E) PLE3-5(E), 6 PLE3-5(E), 8 PLE3-5(E), 9 PLE3-5(E), 6 PLE3-5(E), 8 DPLE3-2(E) 17171717 12 12 12 10 10 10 3 3 1 1 6 8 6 6 6 PLE3-9(E), 18 H-2 PLE3-6(E), 9 10 18 9 1 17 EPLE3-3(E), 7 EPLE3-3(E), 10 DRAWING NOTES: 1. PROVIDE DUAL CHANNEL RACEWAY THAT SHALL BE INSTALLED OVER COUNTER WITH A RECEPTACLE EVERY 24" OC AND DATA CONNECTIONS EVERY 36" OC. ALL RECEPTACLES WITHIN 6' OF SINK SHALL BE GFI TYPE. 2. DATA DROP DDC -CONTRACTOR SHALL ONLY PROVIDE PATHWAY TO ABOVE FINISHED CEILING FOR LOW VOLTAGE WIRING INTO BUILDING MANAGEMENT SYSTEM. 3. CONTRACTOR SHALL COORDINATE WITH ARCHITECT ON FINAL MOUNTING LOCATION OF QUAD RECEPTACLE AND ASSOCIATED DATA DROP WITH CASEWORK CONFIGURATION. 4. ALL 120V CIRCUITS TO THE LEFT OF NOTE 4 SHALL BE CRCUITED TO A 20A-1P DEDICATED CIRCUIT FROM EXISTING PANEL PLE3-6, UNLESS OTHERWISE NOTED. 5. ALL 120V CIRCUITS TO THE RIGHT OF NOTE 5 SHALL BE CIRCUITED TO A 20A-1P DEDICATED CIRCUIT FROM EXISTING PANEL PLE3-9, UNLESS OTHERWISE NOTED. A C D F H 11 12 13 14 15 16 17 18 E304 E304B E305E303 E318A E318 E334 E321 E323 EM UC (E) (E)(E) PLE3-9(E) (E) PLE3-8(E) EPLE3-3(E) DPLE3-3(E) DPLE3-1(E) EPLE3-1(E) ELHE3-1(E) LHE3-1(E) DPHE3-1(E) (E) (E) (E)(E) (E) (E) (E) GENERAL NOTES: A. DEMOLISH ALL CIRCUITING BACK TO SOURCE AND MAKE EXISTING BREAKER SPARE. B. TURN OVER REMOVED WAP IN CORRIDOR E300C TO CIT AS UNIVERSITY PROPERTY. C. DEMOLISH ALL TEL/DATA CABLING SHOWN ON PLANS BACK TO SOURCE. NO CABLES SHALL BE LEFT ABANDONED. GENERAL NOTES: A. ALL EM RECEPTACLE CIRCUITS SHALL COME FROM EXISTING PANEL EPLE3-2. B. ALL NEW NORMAL POWER CONNECTIONS SHALL COME FROM EXISTING PANEL PLE3-9. C. REFER TO ARCHITECT EQUIPMENT SCHEDULE FOR ALL POWER CONNECTIONS WITH ASSOCIATED X' ON PLANS. D. CONTRACTOR SHALL CONNECT THE NEW FIRE ALARM DEVICES INTO THE EXISTING FIRE ALARM SYSTEM. E. SMOKE DAMPERS SHALL BE CIRCUITED TO EXISTING PANEL PLE3-8, CIRCUIT NUMBER 13. 120V 20A-1P BREAKER SHALL BE INSTALLED TO MATCH EXISTING PANEL SPECS AND KAIC RATINGS. F. ALL LAB AIR VALVES SHALL BE CIRCUITED TO EXISTING PANEL PLE3-8, CIRCUIT NUMBER 15. 120V 20A-1P BREAKER SHALL BE INSTALLED TO MATCH EXISTING PANEL SPECS AND KAIC RATINGS. G. ALL NEW FIRE ALARM SHALL BE CONNECTED INTO EXISTING FIRE ALARM SYSTEM. PROVIDE ALL REQUIRED HARDWARE AND PROGRAMMING UPDATES. WIRING SHALL MATCH EXISTING SYSTEM. ALL FIRE ALARM SHALL BE IN RED CONDUIT. These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions3/15/2021 4:09:03 PMC:\Users\crspall\Documents\200278_Corson3rdFloor_E_Central_R20_crspall.rvt20636.00 MRG Partial Third Floor Plan - Power & Special Systems GDD CRS E-200 100% Construction Documents Cornell University Corson Hall Third Floor Laboratory & Office Renovation Ithaca, NY March 5,2021 1/8" = 1'-0" 2 Partial Third Floor Plan - Power & Special Systems 1/8" = 1'-0" 1 Partial Third Floor Plan - Power & Special Systems Demo E344C E331 E300SB E300C A306 A300TB A300UG E301 E310 E340 E344A E344 E344B E320 E309B DN DN UP a,bOS OS OS OS OS OS OS OS 3D 3Da,bD OSVS DD OS E344C E331 E300SB E300C A306 A300TB A300UG E301 E310 E340 E344A E344 E344B E320 E309B DN DN UP 3 3A C D F H 11 12 13 14 15 16 17 18 FACULTY OFFICE E303 LAB E305 LAB E304 DARK ROOM E304B Room E304A Room E306 OFFICE E321 COMPUTATIONAL LAB E323 Room E325OPEN LAB E334 ACID WASH E334A VEST E334B SOIL ROOM E318 Room E309A Room E309 OFFICE 311 KITCHENETTE 317C CONFERENCE 317B OPEN OFFICE 317 FACULTY OFFICE 317A FACULTY OFFICE 315 (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) X1 X1 L1 L1 L1 L1L1L1L1 L1 L1 L1 L1 L1L1L1L1 L1 L1 L1 L1 1 1 1 1 1 (E) (E) (E) (E) (E) L2 L2 L2 L2 L2 L2 L3 L3 L4 L4 L5 X1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L6 L6 2 A C D F H 11 12 13 14 15 16 17 18 E304 E304B E305E303 E318A E318 E334 E321 E323 (E) (E)(E) (E)(E) (E) (E)(E) (E)(E) (E) (E) 1 1 1 1 DEMOLITION NOTES: 1. SALVAGE EXISTING LIGHTING FEEDER FOR REUSE IN NEW WORK PHASE. DRAWING NOTES: 1. CONTRACTOR SHALL UTILIZE SALVAGED LIGHTING FEEDERS AS APPLICABLE FOR NEW LIGHTING. EXTEND FEEDERS AS REQUIRED. 2. OCCUPANCY SENSOR SHALL BE UTILIZED FOR HVAC SYSTEM. SENSOR SHALL NOT TIE INTO LIGHT FIXTURE. GENERAL NOTES: A. CONTRACTOR SHALL TIE NEW EM LIGHTING INTO NEAREST AVAILABLE EM LIGHTING CIRCUIT. B. CONTRACTOR SHALL TIE NEW EXIT LIGHTING INTO NEAREST AVAILABLE EXIT LIGHTING CIRCUIT. These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions3/10/2021 12:06:47 PMC:\Users\crspall\Documents\200278_Corson3rdFloor_E_Central_R20_crspall.rvt20636.00 MRG Partial Third Floor Plan - Lighting GDD CRS E-201 100% Construction Documents Cornell University Corson Hall Third Floor Laboratory & Office Renovation Ithaca, NY March 5,2021 1/8" = 1'-0" 2 Partial Third Floor Plan - Lighting 1/8" = 1'-0" 1 Partial Third Floor Plan - Lighting Demo 6234 39 28 505 A4POU A4P0S E4P0SB E4P0U ROOF E4P0U UP DN LADDER UP DN UP 1019A_A4P0U 1019A_A4P0S M ASD A C D F H 11 12 13 14 15 16 17 18 LEF-11 EXISTING MCC-3 PLE4-7 LEF-1 3 C D F 13 14 15 16 17 18 2 E412B E412C E412 E440 E416 E416A DPLE4-3(E) PLE4-7(E) DRAWING NOTES: 1. GFI WEATHERPROOF RECEPTACLE SHALL BE MOUNTED WITHIN 25' OF EQUIPMENT BY NEC. SHALL BE MOUNTED ON STAINLESS STEEL UNISTRUT. 2. CONTRACTOR SHALL RELOCATE (2)1" CONDUITS FOR NEW DUCT CHASE. COORDINATE IN FIELD WITH HVAC CONTRACTOR. PROVIDE (3)#4AWG & (1)#8EG IN REROUTED CONDUIT. PROVIDE JUNCTION BOX AT EACH CONNECTION POINT. COORDINATE ALL SHUT DOWNS WITH OWNER. 3. NEW BUCKET FOR LEF-1 SHALL UTILIZE SPARE BUCKET AND MATCH ALL MCC SPECS BY WESTINGHOUSE. These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions3/10/2021 12:06:47 PMC:\Users\crspall\Documents\200278_Corson3rdFloor_E_Central_R20_crspall.rvt20636.00 MRG Partial Fourth Floor & Roof Plan - Electrical GDD CRS E-202 100% Construction Documents Cornell University Corson Hall Third Floor Laboratory & Office Renovation Ithaca, NY March 5,2021 1/8" = 1'-0" 2 Partial Roof Plan - Electrical 1/8" = 1'-0" 1 Partial Fourth Floor Plan - Electrical LINE NEUTRAL BLK LOAD WHITE / NEUTRAL RED (LINE) POWER/RELAY PACKWHT. BLK. OFF SWITCH RED (LOAD)BLUBLKREDCONTROL OUTPUTBLU COMMON +24VDCRED BLU CONTROL OUTPUT COMMONBLK +24VDC CEILING SENSOR CEILING SENSOR RED EQUIPMENT: "INSERT DESIGNATION" POWER SOURCE: "INSERT SOURCE" TYPE SUPPLY: INSERT-NORMAL, OR CRITICAL OPERATION POWER, OR OPTIONAL STANDBY, OR LEGALLY REQUIRED, OR LIFE SAFETY EMERGENCY AS APPLICABLE" VOLTAGE: "INSERT APPLICABLE VOLTAGE-208/120V OR 480/277V, ETC." CONDUCTOR COLOR CODING: PHASE A - "BLACK OR BROWN" PHASE B - "RED OR ORANGE" PHASE C - "BLUE OR YELLOW" NEUTRAL - "WHITE OR GRAY" GROUND - GREEN AVAILABLE SHORT CIRCUIT CURRENT: "INSERT AMPS RMS" PROVIDE CUSTOM NAMEPLATE AS INDICATED FOR ALL PANELBOARDS, MCC'S, SWITCHBOARDS, SWITCHGEAR, TRANSFER SWITCHES, GENERATORS ETC. NAMEPLATE SHALL BE ENGRAVED (WHITE LETTERING, BLACK BACKGROUND) AND ATTACHED TO THE EQUIPMENT WITH SCREWS. LETTERING SHALL BE 1/4" HIGH WITH SPACE BETWEEN LINES 1/8" MINIMUM. MINIMUM SHALL BE 8"H x 8"W. PROVIDE SAMPLE NAMEPLATE FOR REVIEW. THE AVAILABLE SHORT CIRCUIT SHOULD BE PROVIDED AT THE SERVICE ENTRANCE. 2. 1. DETAIL NOTES: 3. 4. BRANCH BREAKER NUMBER TYPICAL BLNL5-17 GENERAL DETAIL NOTES: PANEL NAME HL-T106-17 HL-T106-17 RECEPTACLE (EMERGENCY CIRCUIT RECEPTACLE SHALL BE "RED") B. PROVIDE GREEN GROUND WIRE IN ALL RECEPTACLE CIRCUITS. CONNECT TO GROUND BUS IN PANEL. DO NOT INSTALL RECEPTACLES, COMPUTER OR TELEPHONE OUTLETS BACK TO BACK. INSTALL IN ADJACENT STUD CAVITIES, TO REDUCE SOUND TRANSMISSION. A. 1/2" CONDUIT TO ABOVE LAY-IN CEILING WITH BUSHED END GROUNDING PIN ON TOP OR TO LEFT OF OUTLET ON HORIZONTALLY MOUNTED RECEPTACLES 1/2" CONDUIT TO ABOVE LAY- IN CEILING WITH BUSHED END TAPE LABEL, VERIFY COLOR WITH OWNER, ADHERE TO COVERPLATE. (ACTUAL CIRCUIT INFORMATION SHALL BE AS INSTALLED AND NOT NECESSARILY THE SAME CIRCUIT NUMBER AS SHOWN ON THE PLANS.) 3/4" FLEXIBLE CONDUIT OR MC CABLE MAXIMUM 6' LENGTH 3/4" FLEXIBLE CONDUIT OR MC CABLE MAXIMUM 6' LENGTH TYPICAL 2'x4' LUMINAIRE 3/4" EMT 3/4" EMT REFERENCE NOTES: 1. CONTRACTOR SHALL INSTALL NEW BREAKERS AS REQUIRED TO FEED EQUIPMENT. NEW BREAKERS SHALL MATCH ALL EXISTING PANELBOARD SPECS AND KAIC RATINGS. LOAD CEILING SENSOR 120/277V LOW VOLTAGE MOMENTARY SWITCHADDITIONAL SWITCHES AS INDICATED ON THE PLAN VIEWS DETAIL NOTES: 0-10VDC DIMMING SIGNAL PROVIDE ADDITIONAL SENSORS AS INDICATED ON THE PLANS AND AS RECOMMENDED BY THE MANUFACTURERS. ADDITIONAL SWITCH PACKS SHALL BE PROVIDED TO ACCOMMODATE THE SENSOR QUANTITIES, MANUFACTURER RECOMMENDATIONS, AND INDICATED SEQUENCE. 0-10VDC DIMMER SUITABLE FOR USE WITH THE INDICATED LUMINAIRE TYPE POWER SUPPLY. PROVIDE WHERE INDICATED ON THE PLANS. CONTRO L OUTPUT COMMON +24 VDC SWITCH PACKNEUTRAL LINE D 2 1 2 1 SEQUENCE OF OPERATION ROOM UNOCCUPIED: LIGHTING TO BE OFF AFTER TIME DELAY FROM LAST MOTION SENSING. ROOM OCCUPIED: UPON SENSING OF MOTION IN THE SPACE, THE SENSOR SHALL ENABLE THE SWITCH PACK BUT NOT ENERGIZE THE LIGHTING (LOAD) UNTIL MANUAL OPERATION OF THE MOMENTARY SWITCH(ES). LIGHTING SHALL REMAIN ENERGIZED UNTIL MOTION IS NOT SENSED (INITIATE TIME DELAY, SET FOR 30 MINUTES) OR ANOTHER OPERATION OF THE MANUAL MOMENTARY SWITCH AND THEN DE-ENERGIZE. DIMMER SHALL CONTROL OUTPUT WHENEVER ENERGIZED. 1. 2. 3. These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions3/10/2021 12:06:48 PMC:\Users\crspall\Documents\200278_Corson3rdFloor_E_Central_R20_crspall.rvt20636.00 MRG Electrical Details & Schedules GDD CRS E-300 100% Construction Documents Cornell University Corson Hall Third Floor Laboratory & Office Renovation Ithaca, NY March 5,2021NTS 3 CEILING MOUNTED OCCUPANCY SENSOR (MULTIPLE SENSORS) NTS 1 EQUIPMENT NAMEPLATE DETAIL 1/8" = 1'-0" 4 TYPICAL RECEPTACLE IDENTIFICATION REQUIREMENTS NTS 2 TYPICAL BRANCH CIRCUIT WIRING FOR CEILING X1 LED EXIT SIGN EXITRONICS MODEL: VEX SERIES LED 120/277V N/A L6 1'x2' LED LAB SPACE RECESSED FIXTURE W/ UL94 METALUX: 12EN-LD2-43-UNV-L840-CD1 LED 120/277V 4000K L5 2'x4' RECESSED PRISMATIC TROFFER WITH BOTH WHITE AND 620 NM RED LEDS. BOTH WHITE AND RED LEDS SHALL BE CAPABLE OF BEING INDEPENDENTLY POWERED AND DIMMED. KENALL: CSEDI-24-23R/67L-40K8-DCC-DV-2F-2H-SYM LED 120/277V 4000K L4 2'x4' RECESSED PRISMATIC TROFFER KENALL: CSEDI-24-23R/67L-40K8-DCC-DV-2F-2H-SYM LED 120/277V 4000K L3 2'x4' ARCHITECTURAL RECESSED TROFFER METALUX: 24EN-LD2-45-UNV-L835-CD1 LED 120/277V 3500K L2 1'x4' SURFACE MOUNTED VAPORTIGHT METALUX: 4VT2-LD4-4-DR100-W-UNV-L840-CD1-WL LED 120/277V 4000K L1 1'x4' LED LAB SPACE RECESSED FIXTURE W/ UL94 METALUX: 14EN-LD2-43-UNV-L840-CD1 LED 120/277V 4000K TYPE DESCRIPTION MFR. & CATALOG No.LAMP VOLTAGE/BALLAST COLOR REFERENCE NOTES LUMINAIRE SCHEDULE NTS 5 CEILING MOUNTED VACANCY SENSOR VAV-1 VAV 3RD FLOOR 1 120 10.4 DPLE3-3 20/1 2#12 1#12 3/4"C 2#12 1#12 3/4"C X AU 30A NF AU 1 VAV-1 ERHC-6 ELECTRIC REHEAT COIL 3RD FLOOR 7 3 208 19.4 DPLE3-2 30/3 3#10 1#10 3/4"C 3#10 1#10 3/4"C X AU 30A NF AU 1 ERHC-6 ERHC-5 ELECTRIC REHEAT COIL 3RD FLOOR 4.2 3 208 11.7 DPLE3-2 20/3 3#12 1#12 3/4"C 3#12 1#12 3/4"C X AU 30A NF AU 1 ERHC-5 ERHC-4 ELECTRIC REHEAT COIL 3RD FLOOR 1.1 1 120 9.2 DPLE3-3 20/1 2#12 1#12 3/4"C 2#12 1#12 3/4"C X AU 30A NF AU 1 ERHC-4 ERHC-3 ELECTRIC REHEAT COIL 3RD FLOOR 3.9 3 208 10.8 DPLE3-3 20/3 3#12 1#12 3/4"C 3#12 1#12 3/4"C X AU 30A NF AU 1 ERHC-3 ERHC-2 ELECTRIC REHEAT COIL 3RD FLOOR 11.5 3 480 13.8 LHE3-1 20/3 3#12 1#12 3/4"C 3#12 1#12 3/4"C X AU 30A NF AU 1 ERHC-2 ERHC-1 ELECTRIC REHEAT COIL 3RD FLOOR 1 1 120 8.3 DPLE3-3 20/1 2#12 1#12 3/4"C 2#12 1#12 3/4"C X AU 30A NF AU 1 ERHC-1 LEF-1 EXHAUST FAN ROOF 3/4 3 480 1.6 MCC-3 15/3 3#12 1#12 3/4"C 3#12 1#12 3/4"C X AU 30A NF A4POU Y 1 LEF-1 PHASE GROUND CONDUIT PHASE GROUND CONDUIT SWITCH AMPS FUSE SIZE LOC.WEATHER PROOF REF. NOTES ITEM ID NAME ROOM LOCATION HP KW PHASE SYSTEM VOLTS MCA or SYSTEM AMPS PANEL or CONTROL CENTER CIRCUIT BREAKER or "FU" FOR FUSE POWER WIRING FROM PANEL TO CONTROL UNIT POWER WIRING FROM CONTROL UNIT TO EQUIPMENT NEMA SIZE STARTERNEMA TYPEMANUAL MOTOR STARTERMANUAL MOTOR STARTERWITH RELAYMAGNETIC STARTERCOMBINATION MAGNETICSTARTERCOMBINATION REDUCEDVOLTAGE STARTERCOMBINATION STARTERMP/FUSE (F) SIZEADJUSTABLE SPEEDDRIVEADJUSTABLE SPEEDDRIVEWITH BYPASSADJUSTABLE SPEEDDRIVEWITH REDUNDANT ASDPACKAGED CONTROLUNIT FURNISHED BYOTHERSDUPLEX PUMPCONTROLLER BY OTHERSFIRE ALARM FANSHUTDOWN REQUIREDSUPPLY DUCT SMOKEDETECTOR W/ REMOTETEST STATIONRETURN DUCT SMOKEDETECTOR W/ REMOTETEST STATIONEXHAUST DUCT SMOKEDETECTOR W/ REMOTETEST STATIONTHERMOSTATCONNECTIONAQUASTAT CONNECTIONMOTORIZED DAMPERCONNECTIONSTART/STOPPUSHBUTTONSHAND/OFF/AUTOSELECTOR SWITCHCONTROL DEVICELOCATIONSAFETY SWITCH ITEM ID EQUIPMENT POWER SOURCE, PROTECTION & WIRING CONTROL DEVICES AS SHOWN ON THE PLANS BY ITEM DESIGNATION G. "IU" INDICATES INTEGRAL WITH UNIT. F. "NF" INDICATES NON-FUSED. E. "AU" INDICATES CONTROL DEVICES IS LOCATED AT THE UNIT. D. PROVIDE OVERLOADS, SIZE AS REQUIRED, BY THE DIVISION 22/23 CONTRACTOR. C. ALL DEVICES SHALL BE SURFACE MOUNTED UNLESS OTHERWISE NOTED. B. ITEM NUMBER INDICATES EQUIPMENT NUMBER A. ALL DEVICES PROVIDED BY THE DIVISION 26 CONTRACTOR. ELECTRIC EQUIPMENT AND CONTROL SCHEDULE GENERAL NOTES: