permit 40302 Plan with Dimensioned Rooms (2)
permit 40302 Blower Door Test Results/permit 40302 blower door test report.pdf Microsoft Word - Hopgart construction 205 Prospect st Ithaca Energy Tec, LLC 405 Campbell Ave. Ithaca, NY 14850 Date Phone: (607)-330-1334 6/01/2021 Cell: (607)-351-1157 Fax: (607)-330-0702 William Epthimiatos Senior Building Code Officer Building code officer for City of Ithaca Regarding 205 Prospect St, Ithaca NY 14850 Called by Peter Sedlack owner Hopgart Construction to evaluate air changes in newly renovated 2-unit property that is located at 205 Prospect St Ithaca. Address 205 Prospect St Ithaca NY14850 Building is 2 storeys. Second floor 3-bedroom, den, 2 bathrooms apt. Also, first floor 3-bedroom, den, 2-bathroom apt. Property shell insulated as follows. Closed cell Spray foamed R30 to exterior walls and rim. Subfloor of first floor sprayed with R30 closed cell spray foam and attic with well-sealed hatch and R60 loose fill cellulose. Heat provided by LG heat pumps in all bedrooms and main living areas. Water heaters located in basement. Air temp 78 degrees outside and 75 degrees inside. One ventilation fan in each bathroom to exterior of each apt. and one whole apt ventilation fan in each apt. Also, electric stoves in both units with ventilation to exterior Washer and dryer in both units with ventilation to exterior Blowers test out. Each apt approx. 1550 sq. ft General wall height approx. 8 .5 ft second floor and 9ft first floor and partial height basement ACH equation in imperial units. N=60 Q/vol N=number air changes per hour Q= volumetric flow rate of air in cubic ft. per minute Vol= space volume L x B x Height House set up with interior doors open windows and exterior doors closed. No gas appliances in apt house. Heating system mini split heat pumps Blower test First floor DG1000 meter used. Blower adjusted for pressure differences. Base pressure -0.2. Using B ring blower test at 50 pascals pressure was measured for each apt The approx. sq. ft calculated at 1550 sq. ft. Blower test in lower unit 205 prospect St Blower test 654 cfm @50 pascals pressure Cubic ft on first floor apt 13, 950 cubic ft ACH 2.81 ACH in lower first floor apt. This apt passes the ACH 2020 code for air tightness. Second Floor apt Blower test in upper apt 205 Prospect st Base pressure -0.3 fan set at 50 pascals pressure with B ring DG1000 used for test. All windows and ext. doors closed. Sq. ft 1550 Height 8.5 ft Blower test 452cfm Ach of upper apt. cubic ft 13,175 ACH 2.06 This apt also passes the 2020 code for air tightness. Blower door test was (see above) cfm @50 pascals (pressure standard with BPI) Final ACH calculated at 3.0ACH or less. Building with 3 ACH or less passes new IECC 2020 residential code. Additional air sealing in gap in basement done by contractor required to achieve results as one leakage point that had been drilled discovered. Thank you. Blair Macleod SIGNATURE Blair McLeod BPI affiliated company # 1009494 Cc: wepthimiatos@cityofithaca.org Cc hopgart@hotmail.com Cc:stavs88@aol.com permit 40302 Blower Door Test Results/permit 40302 floor 1 blower door.jpg permit 40302 Blower Door Test Results/permit 40302 floor 1 detail.jpg permit 40302 Blower Door Test Results/permit 40302 floor 2 blower door.jpg permit 40302 Blower Door Test Results/permit 40302 floor 2 detail.jpg permit 40302 Fire Doors/permit 40302 Fire Doors.jpg permit 40302 Mini-Split specification/LMN079HVT SUBMITTAL.pdf MultiSITE™ CRC1 - PREMTBVC0 MultiSITE CRC1+ - PREMTBVC1 Dry Contact - PDRYCB300 Job Name/Location: Date: PO No.: Architect: GC: Engr: Mech: Rep: (Company) (Project Manager) For: File Resubmit Approval Other Tag #: For a complete list of available accessories, contact your LG representative. For continual product development, LG reserves the right to change specifications without notice. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com 1. Acceptable operating voltage: 187V-253V. 2. Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745. 3. See Engineering Manual for sensible and latent capacities. 4. All communication / connection (power) cable from the outdoor unit to the indoor unit is field supplied and must be a minimum of four-conductor, 18 AWG, stranded, shielded or unshielded (if shielded, it must be grounded to the chassis of the outdoor unit only), and must comply with applicable local and national codes. 5. Power wiring cable size must comply with the applicable local and national code. 6. The indoor unit comes with a dry helium charge. 7. Corresponding refrigerant piping length is in accordance with standard length of each outdoor unit and the level difference is 0 ft. All capacities are net with a combination ratio between 95 - 105%. 8. Must follow installation instructions in the applicable LG installation manual. Notes: Performance: Nominal Cooling Capacity (Btu/h) Nominal Heating Capacity (Btu/h) Cooling Nominal Test Conditions: Indoor: 80°F DB / 67°F WB Outdoor: 95°F DB / 75°F WB Heating Nominal Test Conditions: Indoor: 70°F DB / 60°F WB Outdoor: 47°F DB / 43°F WB Electrical: Power Supply (V¹/Hz/Ø) Rated Amps (A) 208-230/60/1 Controls Features: • 4-Way auto swing • 24-Hour on/off timer • Auto operation • Auto restart • Chaos wind • Inverter (variable speed fan) • Jet cool/Jet heat • 3M Micro Dust Filter • Self-cleaning indoor coil • Sleep mode • Condensate sensor connection • Built-in Wi-Fi via Smart ThinQ app Optional Accessories: Cooling (°F DB) Heating (°F WB) 57 ~ 77 59 ~ 81 Entering Mixed Air: Unit Data: Refrigerant Type Refrigerant Control Sound Pressure (H/M/L) (±3 dB[A])2 Primary Filter Secondard Filter Net Weight (lbs.) Shipping Weight (lbs.) R410A EEV Washable Pre-filter 3M Micro Dust Fan: Type Quantity Motor/Drive Air Flow H/M/L (CFM) Cross Flow 1 Brushless Digitally Controlled/Direct Page 1 of 2 Included Accessories: • Wireless Remote Controller — AKB74955602 Piping: Installed Liquid Pipe (in., O.D.) Installed Vapor Pipe (in., O.D.) Liquid Connection (in., O.D.) Vapor Connection (in., O.D.) Drain (in., O.D. / I.D.) Temperature Sensor 27/32 , 5/8 Thermistor 7,000 Multi F Wall Mounted High Efficiency Indoor Unit ø3/8 ø1/4 ø3/8 18.3 8,100 35 / 31 / 26 ø1/4 SB_MultiF_WallMount_HiEff_IDU_LMN079HVT_2018_03_20_064546 254 / 204 / 148 LMN079HVT 7,000 Btu/h 23.4 0.4 Job Name/Location: Tag No.: Date: PO No.: For continual product development, LG reserves the right to change specifications without notice. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com Page 2 of 2 Multi F Wall Mounted High Efficiency Indoor Unit SB_MultiF_WallMount_HiEff_IDU_LMN079HVT_2018_03_20_064546 LMN079HVT 7,000 Btu/h permit 40302 Mini-Split specification/LMU360HHV SUBMITTAL.pdf Multi F ODU (CHV) Date: Job Name/Location: PO No.: Architect: Engr: GC: Rep: For: File Approval Mech: Resubmit Other Tag #: (Company) (Project Manager) Performance: Cooling Nominal Test Conditions: Heating Nominal Tes t Conditions: Indoor: 80°F DB/67°F WB Indoor: 70°F DB/60°F WB Outdoor: 95°F DB/75°F WB Outdoor: 47°F DB/43°F WB Electrical: Power Supply (V¹/Hz/Ø) 208‐230/60/1 MOP (A) MCA (A) Cooling Rated Amps (A) Heating Rated Amps (A) Compressor (A) Fan Motor (A) Piping: Controls Features: •Auto operation •Auto restart •Defrost/Deicing •Inverter (variable speed compressor) •Low ambient operation to 14F (cooling mode) Operating Range: Cooling (°F DB) Heating (°F WB) Unit Data: R410A EEV GoldFin™ Compressor: Quantity 1 Type Twin Rotary Oil/Type FVC68D Fan: Type Propeller Quantity Fan Motor/Drive Brushless Digitally Controlled/Direct Airflow Rate (CFM) Notes: Refrigerant Charge (lbs.) Liquid Line (in, OD) Vapor Line (in, OD) Max Total Piping² (ft) Max ODU to IDU Piping3 (ft) Piping Length4 (no add'l refrigerant, ft) Max Elevation between ODU and IDU (ft) Max Elevation between IDU and IDU (ft) Refrigerant Type Refrigerant Control Sound Pressure³ (Cool/Heat) ±3 dB(A) Net/Shipping Weight (lbs) Heat Exchanger Coating Min Number of Indoor Units Max Number of Indoor Units 2 MOP ‐ Maximum Overcurrent Protection MCA ‐ Minimum Circuit Ampacity ODU ‐ Outdoor Unit IDU ‐ Indoor Unit Page 1 of 3 For continual product development, LG reserves the right to change specifications without notice. ©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserv ed. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com. For a complete list of available accessories, contact your LG representative. Cooling (Min‐Rated‐Max, Btu/h) Heating (Min‐Rated‐Max, Btu/h) Max Heating at 5°F (Btu/h) Cooling Power Input (Min‐Rated‐Max, kW) Heating Power Input (Min‐Rated‐Max, kW) Optional Accessories: PI‐485 Integration Board ‐ PMNFP14A1 AC Smart IV ‐ PACS4B000 ACP IV - PACP4B000 Power Distribution Indicator PQNUD1S41 MultiSITETM CM - PBACNBTR0A LonWorks® Gateway ‐ PLNWKB100 Y-Branch - PMBL5620 ACP IV BACnet Gateway - PQNFB17C2 AC Smart IV BACnet® Gateway - PBACNA000 Low Ambient Wind Baffle (Cooling operation to -4°F) - ZLABGP04A x2 2 Port BD Unit ‐ PMBD3620 3 Port BD Unit ‐ PMBD3630 4 Port BD Unit ‐ PMBD3640 4 Port BD Unit ‐ PMBD3641 1.Acceptable operating voltage: 187V‐253V . 2.Piping lengths are equivalent. 3.180.4 ft of Main Piping + 49.2 ft of Branch Piping. 4.16 ft of Main Piping + 131 ft of Branch Piping. 5.At least one BD Unit is required for system operaon; a maximum of two can be installed per ODU with use of Y‐branch accessory (PMBL5620). 6.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. 7.All power/communicaon cable to be minimum 16 AWG from the outdoor unit to the BD unit and 18 AWG from the BD unit to the indoor unit. 8.All power/communicaon cable to be 4‐conductor, stranded, shielded and must comply with applicable local and national code. 9.Power wiring cable size must comply with the applicable local and naonal code. 10. See Performance Data Manual Capacity Tables for ODU sensible and latent capacies. 11. See Combination Data Manual for allocaon of ODU rated capacity to each connected IDU when all are calling for full capacity. Allocation percentages should be applied to ODU capacity at design conditions. 12. This data is rated 0 above sea level, with 115 of refrigerant line and a 0 level difference between outdoor and i ndoor units. All capacities are net with a combination ratio between 95 – 105%. 13. Must follow installaon instrucons in the applicable LG installaon manual. •Restart delay (3-minutes) •Self diagnosis •Soft start •Factory installed Drain Pan Heater Required5 Accessories: BACnet® is a registered trademark of ASHRAE. LonWorks is a trademark of Echelon Corporation. Energy Star rating at least for Non-Ducted combinations; refer to AHRI directory for complete list. 98.4 13,455~41,000~50,200 25.06 54 / 57 222.7/249.1 SB_MultiF_MAX_LGRED_HP_LMU360HHV_2017_11_21_10 2236 229.6 12.34 2 0.73 x 2 475.7 45 30.2 49.2 147.6 2,119 x 2 0.96 ~ 2.93 ~ 3.94 25.06 11,700~36,000~46,733 20.4 0.72 ~ 2.40 ~ 3.75 14 to +118 41,000 LMU360HHV 5 Ø3/8 x 1 Ø3/4 x 1 -13 to +75 Multi F MAX with LGRED° Heat Pump Outdoor Unit Job Name/Location: Tag #: Date: PO No.: Page 2 of 3 For continual product development, LG reserves the right to change specifications without no tice. ©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com. SB_MultiF_MAX_LGRED_HP_LMU360HHV_2017_11_21_1022 36 LMU360HHV Multi F MAX with LGRED° Heat Pump Outdoor Unit Job Name/Location: Tag #: Date: PO No.: For continual product development, LG reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com Page 3 of 3 SB_MultiF_MAX_LGRED_HP_LMU360HHV_2017_11_21 _102236 LMU360HHV Multi F MAX with LGRED° Heat Pump Outdoor Unit permit 40302 Mini-Split specification/LSN090HSV5 Submittal.pdf SB_MultiF_WallMount_HiEff_IDU_LSN090HSV5.pdf MultiSITE™ CRC1 - PREMTBVC0 MultiSITE CRC1+ - PREMTBVC1 Dry Contact - PDRYCB300 Job Name/Location: Date: PO No.: Architect: GC: Engr: Mech: Rep: (Company) (Project Manager) For: File Resubmit Approval Other Tag #: For a complete list of available accessories, contact your LG representative. For continual product development, LG reserves the right to change specifications without notice. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com 1. Acceptable operating voltage: 187V-253V. 2. Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745. 3. See Engineering Manual for sensible and latent capacities. 4. All communication / connection (power) cable from the outdoor unit to the indoor unit is field supplied and must be a minimum of four-conductor, 18 AWG, stranded, shielded or unshielded (if shielded, it must be grounded to the chassis of the outdoor unit only), and must comply with applicable local and national codes. 5. Power wiring cable size must comply with the applicable local and national code. 6. The indoor unit comes with a dry helium charge. 7. Corresponding refrigerant piping length is in accordance with standard length of each outdoor unit and the level difference is 0 ft. All capacities are net with a combination ratio between 95 - 105%. 8. Must follow installation instructions in the applicable LG installation manual. Notes: Performance: Nominal Cooling Capacity (Btu/h) Nominal Heating Capacity (Btu/h) Cooling Nominal Test Conditions: Indoor: 80°F DB / 67°F WB Outdoor: 95°F DB / 75°F WB Heating Nominal Test Conditions: Indoor: 70°F DB / 60°F WB Outdoor: 47°F DB / 43°F WB Electrical: Power Supply (V¹/Hz/Ø) Rated Amps (A) 208-230/60/1 Controls Features: • 4-Way auto swing • 24-Hour on/off timer • Auto operation • Auto restart • Chaos wind • Inverter (variable speed fan) • Jet cool/Jet heat • 3M Micro Dust Filter • Self-cleaning indoor coil • Sleep mode • Condensate sensor connection • Built-in Wi-Fi via Smart ThinQ app Optional Accessories: Cooling (°F DB) Heating (°F WB) 57 ~ 77 59 ~ 81 Entering Mixed Air: Unit Data: Refrigerant Type Refrigerant Control Sound Pressure (H/M/L) (±3 dB[A])2 Primary Filter Secondard Filter Net Weight (lbs.) Shipping Weight (lbs.) R410A EEV Washable Pre-filter 3M Micro Dust Fan: Type Quantity Motor/Drive Air Flow H/M/L (CFM) Cross Flow 1 Brushless Digitally Controlled/Direct Page 1 of 2 Included Accessories: • Wireless Remote Controller — AKB74955602 Piping: Installed Liquid Pipe (in., O.D.) Installed Vapor Pipe (in., O.D.) Liquid Connection (in., O.D.) Vapor Connection (in., O.D.) Drain (in., O.D. / I.D.) Temperature Sensor 27/32 , 5/8 Thermistor 9,000 Multi F Wall Mounted High Efficiency Indoor Unit ø3/8 ø1/4 ø3/8 18.3 10,900 36 / 32 / 27 ø1/4 SB_MultiF_WallMount_HiEff_IDU_LSN090HSV5_2018_03_20_064547 268 / 218 / 169 LSN090HSV5 • Compatible with Single Zone HSV5 Outdoor Units 9,000 Btu/h 23.4 0.4 Job Name/Location: Tag No.: Date: PO No.: For continual product development, LG reserves the right to change specifications without notice. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com Page 2 of 2 Multi F Wall Mounted High Efficiency Indoor Unit SB_MultiF_WallMount_HiEff_IDU_LSN090HSV5_2018_03_20_064547 LSN090HSV5 9,000 Btu/h permit 40302 Plan with Dimensioned Rooms/04 30002 201015 CD A1.pdf 30002 kitchen changes First Floor Level 2 Alteration and Second floor Addition to 205 Prospect Street Two Family Residence each apartment having 3 bedrooms Reduction in Footprint Size 327 South Geneva Street Ithaca, New York 14850 tel/ans 607-277-2701 cell 607-275-7000 email DRH@DanielRHirtler.com web site www.danielrhirtler.com A1 4 of 14 30002 Daniel R. Hirtler, Architect PLLC SD CO SD SD SD SD SD CO Construction Documents 9/24/2020 revised 10/15/2020 Proposed First Floor Plan Level 2 Alteration P1p 1/4" = 1'-0" combined Living Room Dining Area Kitchen 468 SF 340 SF habitable 9.4% light 4.5% vent Bedroom 2 124 SF 18.0% light 9.2% vent Bedroom 1 127 SF 8.8% light 4.5% vent Bedroom 3 116 SF 19.3% light 9.8% vent Kitchen Bath D Covered Exterior Stair Hall Stair Hall UP Second Floor Plan Addition P2 1/4" = 1'-0" 9'-9"9'-9"11'-8 3/4" 12'-4 3/4" 15'-11 3/4" 30'-6 3/4" 9'-11 1/2" 11'-11 1/2" Living Room Dining Area 342 SF Bedroom 3 121 SF habitable 8.7% light 4.4% vent Bedroom 2 121 SF habitable 8.7% light 4.4% vent 119 SF habitable 18.6% light 9.5% vent Kitchen 11'-2 3/4" Bath Bath Covered Exterior Stair Stair Hall DN Covered Landing 87 SF 12.6% light 6.4% vent Deck DN (143 SF) 21'-5 1/4" 14'-0 1/2" 9'-1 3/4" 113 SF Bedroom 1 129 SF habitable 14.2% light 7.3% vent DN Garbage and Recycling UP 36x80 1hr FPSC Apt 2 Existing First Floor Plan P1e 1/8" = 1'-0" Bedroom 1 Apartment 1 Entry Living Room Dining Room Bedroom 2 Bedroom 3 Kitchen Enclosed Porch Bedroom Enclosed Porch Living Dining Kitchenette Bathroom Bathroom 1/2 Bath closet closet laundry Apartment 2 Entry Apartment 1 Entry Apartment 2 Entry closet Remove existing enclosed porch. Remove existing 1 story construction 7'-9" covered porch 5'-6" covered porch 35'-4 1/4" existing building frame 9'-3 1/2" new exterior stair frame W W/D 9'-9 3/4" 11'-10 1/2" 9'-3 3/4" 9'-6 1/2" 9'-11 1/4" 12'-6 1/4" 12'-6 1/4" 10'-1 1/2"15'-6 1/2"7'-5 3/4" 21'-10 1/2" 8'-7 1/2" 15'-8 3/4" Bath D1 36x80 W1t W2 W3 W2 W1 egress 30x80 60x80 bi-pass W1 egress W1 W1to Laundry Apt 1 24x80 30x8030x80 30x80 30x80 42x80 2 panel 96x80 double bi-pass Den 1 hour rated separation between dwelling and shared hall R302.1 Ceiling of first floor shall be constructed as a 1 hour rated dwelling unit separation. R302.3 All construction supporting the second floor deck shall be protected by 1 hour rated construction. R302.3.1 1 hour rated separation wall between dwelling and shared hall R302.1 Terminate rated wall at underside of 1 hour rated ceiling assembly in stair hall. 36x80 1hr FPSC W1 egress W1 W1 egress D2 36x80 Bath exhaust 110 CFM intermittent exhaust (50 CFM intermittent minimum) Table M1505.4.4 Bath exhaust 110 CFM intermittent exhaust (50 CFM intermittent minimum) Table M1505.4.4 range hood exhaust 100 CFM minimum intermittent exhaust 10'-3 3/4" 30x80 30x80 30x80 120x80 double bi-pass W1 egress W1 egress W1 egress W1 W1t 3'-1 1/4" W1 W1 W1 W1 W1 W1 egress W1 SD SD SD SDCO SD Den 3'-11" W4to Coats 48x80 60x80 bi-pass 60x80 bi-pass Bath exhaust 110 CFM intermittent exhaust (50 CFM intermittent minimum) Table M1505.4.4 Bath exhaust 110 CFM intermittent exhaust (50 CFM intermittent minimum) Table M1505.4.4 range hood exhaust 100 CFM minimum intermittent exhaust Whole House Ventilation System 60 CFM continuous fresh air flow minimum using heat recovery ventilator Table M1505.4.3 (1) Whole House Ventilation System 60 CFM continuous fresh air flow minimum using heat recovery ventilator Table M1505.4.3 (1) 30x80 30x80 pocket 30x80 pocket D2 36x80 DN Landing DN SDCO DW DW 48x80 2 panel pan pan 6'-4" 32'-1 1/2" existing building frame12'-6" addition frame15'-11 3/4" exterior stair frame new concrete sidewalk new retaining wall new 42" high wood fence (guard) step down to driveway 6" wide concrete curb (for grade isolation) The front yard is raised about 6 ft above the city sidewalk. There is a parged stone retaining wall with a paved top surface which slopes down toward the sidewalk. The slope is uncomfortable as a usable terrace. The goal is to get a level terrace with a railing. I propose building a level wood deck which sits on the pavement at the house, and is raised above the pavement at the front edge on legs which form the posts of the guard rail. the deck would restrain the guard rail posts so as not to need the pavement to resist the horizontal loads on the rail. 60x80 bi-pass Replace original rear wing construction with new construction at the same building footprint. 3'-1 1/4" See "Fire Resistance Rated Assemblies" note on Drawing A0a for description of the construction of the fire rated assemblies used in this project. attic access Provide attic access (22" x 30" R.O.) as per R807.1 to reach all parts of attic space S2 A3 S1 A3 S3 A3 S5 A3 S2 A3 S1 A3 S3 A3 S5 A3 60x80 bi-pass mic ref mic ref See Stair Dimensions on drawing A0a. 36" high handrail 36" high handrail extends past window to become 36" high guard rail at window as per R312.1. 36" high handrail