Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
LMU360HHV SUBMITTAL
Date: Job Name/Location: PO No.: Architect: Engr: GC: Rep: For:File Approval Mech: Resubmit Other Tag #: (Company)(Project Manager) Performance: Cooling Nominal Test Conditions:Heating Nominal Test Conditions: Indoor:80°F DB/67°F WB Indoor:70°F DB/60°F WB Outdoor:95°F DB/75°F WB Outdoor:47°F DB/43°F WB Electrical: Power Supply (V¹/Hz/Ø)208‐230/60/1 MOP (A) MCA (A) Cooling Rated Amps (A) Heating Rated Amps (A) Compressor (A) Fan Motor (A) Piping: Controls Features: •Auto operation •Auto restart •Defrost/Deicing •Inverter (variable speed compressor) •Low ambient operation to 14F (cooling mode) Operating Range: Cooling (°F DB) Heating (°F WB) Unit Data: R410A EEV GoldFin™ Compressor: Quantity 1 Type Twin Rotary Oil/Type FVC68D Fan: Type Propeller Quantity Fan Motor/Drive Brushless Digitally Controlled/Direct Airflow Rate (CFM) Notes: Refrigerant Charge (lbs.) Liquid Line (in, OD) Vapor Line (in, OD) Max Total Piping² (ft) Max ODU to IDU Piping3 (ft) Piping Length4 (no add'l refrigerant, ft) Max Elevation between ODU and IDU (ft) Max Elevation between IDU and IDU (ft) Refrigerant Type Refrigerant Control Sound Pressure³ (Cool/Heat) ±3 dB(A) Net/Shipping Weight (lbs) Heat Exchanger Coating Min Number of Indoor Units Max Number of Indoor Units 2 MOP ‐ Maximum Overcurrent Protection MCA ‐ Minimum Circuit Ampacity ODU ‐ Outdoor UnitIDU ‐ Indoor Unit Page 1 of 3 For continual product development, LG reserves the right to change specifications without notice. ©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com. For a complete list of available accessories, contact your LG representative. Cooling (Min‐Rated‐Max, Btu/h) Heating (Min‐Rated‐Max, Btu/h) Max Heating at 5°F (Btu/h) Cooling Power Input (Min‐Rated‐Max, kW) Heating Power Input (Min‐Rated‐Max, kW) Optional Accessories: PI‐485 Integration Board ‐ PMNFP14A1 AC Smart IV ‐ PACS4B000 ACP IV - PACP4B000 Power Distribution Indicator - PQNUD1S41 MultiSITETM CM - PBACNBTR0A LonWorks® Gateway ‐ PLNWKB100 Y-Branch - PMBL5620 ACP IV BACnet Gateway - PQNFB17C2 AC Smart IV BACnet® Gateway - PBACNA000 Low Ambient Wind Baffle (Cooling operation to -4°F) - ZLABGP04A x2 2 Port BD Unit ‐ PMBD3620 3 Port BD Unit ‐ PMBD3630 4 Port BD Unit ‐ PMBD3640 4 Port BD Unit ‐ PMBD3641 1.Acceptable operating voltage: 187V‐253V. 2.Piping lengths are equivalent. 3.180.4 ft of Main Piping + 49.2 ft of Branch Piping. 4.16 ft of Main Piping + 131 ft of Branch Piping. 5.At least one BD Unit is required for system operaƟon; a maximum of two can be installed per ODU with use of Y‐branch accessory (PMBL5620). 6.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. 7.All power/communicaƟon cable to be minimum 16 AWG from the outdoor unit to the BD unit and 18 AWG from the BD unit to the indoor unit. 8.All power/communicaƟon cable to be 4‐conductor, stranded, shielded and must comply with applicable local and national code. 9.Power wiring cable size must comply with the applicable local and naƟonal code. 10. See Performance Data Manual Capacity Tables for ODU sensible and latent capaciƟes. 11. See Combination Data Manual for allocaƟon of ODU rated capacity to each connected IDU when all are calling for full capacity. Allocation percentages should be applied to ODU capacity at design conditions. 12. This data is rated 0 Ō above sea level, with 115 Ō of refrigerant line and a 0 Ō level difference between outdoor and indoor units. All capacities are net with a combination ratio between 95 – 105%. 13. Must follow installaƟon instrucƟons in the applicable LG installaƟon manual. •Restart delay (3-minutes) •Self diagnosis •Soft start •Factory installed Drain Pan Heater Required5 Accessories: BACnet® is a registered trademark of ASHRAE. LonWorks is a trademark of Echelon Corporation. Energy Star rating at least for Non-Ducted combinations; refer to AHRI directory for complete list. 98.4 13,455~41,000~50,200 25.06 54 / 57 222.7/249.1 SB_MultiF_MAX_LGRED_HP_LMU360HHV_2017_11_21_102236 229.6 12.34 2 0.73 x 2 475.7 45 30.2 49.2 147.6 2,119 x 2 0.96 ~ 2.93 ~ 3.94 25.06 11,700~36,000~46,733 20.4 0.72 ~ 2.40 ~ 3.75 14 to +118 41,000 LMU360HHV 5 Ø3/8 x 1 Ø3/4 x 1 -13 to +75 Multi F MAX with LGRED° Heat Pump Outdoor Unit Job Name/Location: Tag #: Date: PO No.: Page 2 of 3 For continual product development, LG reserves the right to change specifications without notice. ©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com.SB_MultiF_MAX_LGRED_HP_LMU360HHV_2017_11_21_102236 LMU360HHV Multi F MAX with LGRED° Heat Pump Outdoor Unit Job Name/Location: Tag #: Date: PO No.: For continual product development, LG reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com Page 3 of 3SB_MultiF_MAX_LGRED_HP_LMU360HHV_2017_11_21_102236 LMU360HHV Multi F MAX with LGRED° Heat Pump Outdoor Unit