Loading...
HomeMy WebLinkAbout2004_Sibley Hall_IT Solutions Renovation_Construction SetCB CB CB CBCB CBCB CB CB CB CB CBCB CB CBCB MENNEN HALL LYON HALL FOUNDERS HALL3005McGRAW PLACEWAR MEMORIAL3013 WEST AVENUEJOHNSON MUSEUM OF ART2086 CENTRAL AVENUECENTRAL AVENUEOLIVE TJADEN HALL2007 WHITE HALL2002 MCGRAW HALL2003 MORRILL HALL2001 URIS LIBRARY2010 UNIVERSITY AVENUE OLIN LIBRARY2047 SIBLEY HALL2004 LINCOLN HALL2008 FOUNDRY2015 GOLDWIN SMITH HALL2013 STIMSON HALL2011 RAND HALL2017 EAST AVENUEBAKER LAB2019 ROCKEFELLER HALL2014 FOREST HOME DR CLARK HALL2082 BIG RED BARN2040 NEWMAN ACCELERATOR BUILDING2029 NEWMAN LAB2029 MALOTT HALL2081 BAILEY HALL1024 SAVAGE HALL2032 GARDEN AVENUEGARDEN AVENUEROBERTS HALL1080N FOREST HOME DR KENNEDY HALL1080S TOWER ROAD TOBOGGAN LODGE BAKER TOWER KROCH LIBRARY2047A 800UNIV. AV.THETA DELTA CHI4755 LINCOLN HALLEAST2008 SPACE SCIENCESBUILDING2084 OLIN CHEMISTRYRESEARCH LAB.2083 KINZELBERGHALL2032A MVRWEST1015W CHILLEDWATERPLANT 15101 ANDREWDICKSONWHITEHOUSE2006 C&CC1016 FOUNDRY KILN SHED2015A M VAN RENSSELAER HALL1015A 1024A MICRO-KELVIN2075 NEWMAN LABSUBSTATION2029A PAUL MILSTEIN HALL3802 SCIE NCES DRI VESCIENCES DRIVE PRESI DENTS' DRIVERESERVOIR AVE 626THURSTON AV.4767 Thurston AveBridge4411 Beebe DamFoot BridgeBridge4413 Supension Bridge4409 PHYSICALSCIENCESBUILDING2076 McGRAWTOWER2010T BRIDGEHEB PEDESTRIAN44OOA JOHNSON ARTADDITION KLARMAN HALL2013A UP UP DN DN FP BL MONUMENT PLATFORM **Remnants of formerMorse Chemical labin this area; soil maycontain chemicaland heavy metal residuals.Contact EH&Sprior to anysubsurface work.** 14 389715 7697 273 26 840 185 215 102 253 127255 115 152 154 197 188 300199 135 36 141141128126128141145 3471 155 172164185 134 702 604 143122 210 47 32 47 37 100 64 438 62 1304 176163171157 923 12 259 513 83 144149 187173370205238 43 159142203143193 261C240A 260B260A 260 200JA 220 250 235J 200SF 235 235H235G235F235E235D235C235B 200UA 253240H 223 224222 200CC 200EA 226 200CD 200EB 200JB 200TC 261 261B 261A 240G240F240E240D240C 240 208A 204 240B 252 200CA 207A 200SD 200TB 200SC 235A200SB 200SE 200CB 221219217 215213211209207203201 200TA 216214212210 208 200SA 202200 UP DN UP DN UP UP DN DN UP UP UP UP UNIVERSITY AVENUE SIBLEY HALL 2004 AREA OF WORK EXTERIOR ELEVATION 1 X-100 X-100 1 1 INTERIOR ELEVATION 1 X-100 SECTION MARKER 1 X-100 ENLARGED DETAIL CONSTRUCTION KEYED NOTE DEMOLITION KEYED NOTE DRAWING REVISION NOTE LINETYPE: TO BE PROVIDED / NEW LINETYPE: DEMOLITION / TO BE RELOCATED LINETYPE: EXISTING TO REMAIN # # # 1 1 1 11 AREA OF WORK T-001 TITLE SHEET ARCHITECTURAL A-001 GENERAL NOTES, SYMBOLOGY, AND ABBREVIATIONS A-101 PARTIAL SECOND FLOOR DEMOLITION PLAN A-102 PARTIAL SECOND FLOOR RENOVATION PLAN FIRE PROTECTION FP-001 FIRE PROTECTION FP-101 PARTIAL SECOND FLOOR PLAN MECHANICAL M-001 MECHANICAL GENERAL NOTES AND SYMBOL LEGENDS M-101 BASEMENT AND FIRST FLOOR MECHANICAL DEMOLITION & RENOVATION PLANS M-102 SECOND FLOOR MECHANICAL DEMOLITION & RENOVATION PLANS M-401 MECHANICAL CONTROLS M-402 MECHANICAL CONTROLS M-501 MECHANICAL SCHEDULES AND DETAIL M-502 SCHEDULES ELECTRICAL E-001 GENERAL NOTES, SCHEDULES AND SYMBOL LEGENDS E-101 PARTIAL 2ND FLOOR ELECTRICAL DEMOLITION PLANS E-102 BASEMENT ELECTRICAL RENOVATION PLAN E-103 PARTIAL 2ND FLOOR LIGHTING RENOVATION PLAN E-104 PARTIAL 2ND FLOOR ELECTRICAL RENOVATION PLANCORNE LL U N I V E R SI TYFOUN D E D 5681 AD CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 Cornell University 921 UNIVERSITY AVE ITHACA, NEW YORK 14850 SIBLEY HALL IT SOLUTIONS RENOVATIONS T-001 13291868 TITLE SHEET FE DESIGN JGC 2004 JUNE 4, 2021 SIBLEY HALL IT SOLUTIONS RENOVATIONS BUILDING CODE SUMMARY APPLICABLE CODES 2020 NYS BUILDING CODE 2020 NYS EXISTING BUILDING CODE 2020 NYS FIRE CODE 2020 NYS PLUMBING CODE 2020 NYS MECHANICAL CODE 2020 NYS ENERGY CONSERVATION CODE 2009 ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 2010 AMERICANS WITH DISABILITY ACT (ADA) PROJECT SUMMARY THIS PROJECT INCLUDES THE RENOVATION OF (2,200) SF OF OFFICE SPACE. THE WORK IS ALTERATION LEVEL 2. BUILDING LIMITATIONS CONSTRUCTION CLASSIFICATION:5B CLASSIFICATION OF HAZARDS:NONE HIGH-RISE BUILDING:NO EXTINGUISHING REQUIREMENT:THE EXISTING BUILDING IS SPRINKLERED OCCUPANCY OCCUPANCY CLASSIFICATION:BUSINESS (B) GENERAL SYMBOLS LEGEND DRAWING INDEXPROJECT SCOPE THE PURPOSE OF THIS PROJECT IS TO RENOVATE/ RECONFIGURE THE IT SOLUTIONS AREA ROOM 261 IN SIBLEY HALL (2004). THE PROJECT WILL INCLUDE NEW WALLS, RECONFIGURED STOREFRONT SYSTEMS, AND NEW FINISHES (OWNER PROVIDED). ALSO, INCLUDED IN THE PROJECT WILL BE UPGRADES TO MECHANICAL, FIRE PROTECTION, AND ELECTRICAL SYSTEMS/ EQUIPMENT. SITE LOCATION -SIBLEY HALL (2004) KEY PLAN -SIBLEY HALL -SECOND FLOOR 1 04/30/2021 ISSUE FOR 100% DD REVIEW 2 05/11/2021 ISSUE FOR DEMOLITION PERMIT 3 06/01/2021 ISSUE FOR COORDINATED REVIEW 4 06/04/2021 ISSUE FOR CONSTRUCTION WALL -EXISTING WALL -METAL STUD/ GWB WALL -CONCRETE WALL -CMU WALL -BRICK ITEMS FOR DEMOLITION DOOR/ WALL -EXISTING DOOR/ WALL -NEW DOOR/ WALL -DEMOLITION TAG -DOOR TAG -WINDOW TAG -WALL TAG -ROOM # CENTER LINE PHOTO REFERENCE LEVEL MARKER COLUMN GRID MARKER ELEVATION MARKER ELEVATION CHANGE ARROWS BREAK LINE SYMBOLS 0' -0" 101 1t X-X X 2B00UA CL 1 Name Elevation A101 1 1 1 0 DN UP ABBREVIATIONS A &AND @ AT ACT ACOUSTICAL CEILING TILE ALT ALTERNATE ALUM ALUMINUM AVG AVERAGE AFF ABOVE FINISH FLOOR B BD BOARD BLDG BUILDING BOD BOTTOM OF DECK BSMT BASEMENT C CG CORNER GUARDS CJ CONTROL JOINT CLG CEILING CL CENTER LINE CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONF CONFERENCE CONT CONTINUOUS CORR CORRIDOR CPT CARPET CRS COURSE(S) CT CERAMIC TILE D DEMO DEMOLITION DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DN DOWN DO DOOR OPENING DWG DRAWING E EA EACH EJ EXPANSION JOINT ELEC ELECTRIC ELEV ELEVATION/ ELEVATOR EPDM RUBBER ROOF MEMBRANE EQ EQUAL EX'G EXISTING EXT EXTERIOR F FD FLOOR DRAIN FDN FOUNDATION FEC FIRE EXTINGUISHER CABINET FFE FINISH FLOOR ELEVATION FRP FIBER REINFORCED POLYESTER FT FOOT/FEET FTG FOOTING G GA GAGE GALV GALVANIZED GC GENERAL CONTRACTOR GEN GENERAL GL GLASS GWB GYPSUM WALL BOARD H HC HANDICAPPED HT HEIGHT HM HOLLOW METAL HR HOUR HVAC HEATING, VENTILATING & AC J JAN JANITOR L LAV LAVATORY LB/#POUND LGMF LIGHT GAGE METAL FRAMING M MFR MANUFACTURER MAT MATERIAL MAX MAXIMUM MEZZ MEZZANINE MIN MINIMUM MO MASONRY OPENING MTL METAL N NA NOT APPLICABLE NIC NOT IN CONTRACT NR NOT RATED NTS NOT TO SCALE O OC ON CENTER OD OUTSIDE DIAMETER OPNG OPENING OSB ORIENTER STRAND BOARD P +/-PLUS OR MINUS PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT PRESSURE TREATED Q QTY QUANTITY R R RISER RD ROOF DRAIN REF REFRIGERATOR REQ REQUIRED REV REVISION RO ROUGH OPENING RTU ROOF TOP UNIT S SHTG SHEATHING SIM SIMILAR SF SQUARE FOOT/ FEET SS STAINLESS STEEL STL STEEL STD STANDARD T T TREAD T&G TONGUE & GROOVE TEL TELEPHONE TEMP TEMPERATURE TOS TOP OF STEEL TV TELEVISION TYP TYPICAL U UEV UNEVEN DOORS W/ VISION PANEL UEF UNEVEN FLUSH DOOR V VCT VINYL COMPOSITION TILE VIF VERIFY IN FIELD W W/O WITHOUT WD WOOD CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 921 UNIVERSITY AVE ITHACA, NEW YORK 14850 SIBLEY HALL IT SOLUTIONS RENOVATIONS A-001 13291868 GENERAL NOTES, SYMBOLOGY, AND ABBREVIATIONS J. COOLBAUGH JGC 2004 JUNE 4, 2021 SCOPE OF WORK 1.0 REMOVE AND SALVAGE EXISTING STOREFRONT SYSTEM FOR REINSTALL IN NEW LOCATIONS. 2.0 PROVIDE NEW OFFICE LAYOUT WITH STUD WALLS TO DECK. 3.0 PROVIDE STRUCTURAL FRAMING FOR METAL TRACK AND GATE SYSTEM. 4.0 INSTALL OWNER SUPPLIED STOREFRONT SYSTEM. GENERAL NOTES 1.0 DESIGN, CONSTRUCTION AND SAFETY SHALL CONFORM TO ALL LOCAL, STATE AND OWNER SPECIFIC CODES, INCLUDING (BUT NOT LIMITED TO) THE NEW YORK STATE UNIFORM FIRE PROTECTION AND BUILDING CODE, LATEST REVISION, THE NFPA 101 LIFE SAFETY CODE, LATEST REVISION, ANSI A117.1 - LATEST REVISION, OSHA, AND ANY OTHER CODES GOVERNED BY THE JURISDICTION IN WHICH THIS PROJECT IS BEING CONSTRUCTED. 2.0 THIS CONTRACT REQUIRES COMPLETE, FINISHED WORKABLE PROJECT OF THE AREAS INDICATED BY THE CONTRACT DOCUMENTS, AND SHALL INCLUDE ALL MATERIALS AND LABOR NECESSARY TO COMPLETE, REGARDLESS OF WHETHER OR NOT ALL WORK OR EACH ITEM IS SPECIFICALLY INDICATED ON ANY OTHER PORTION OF THE DRAWINGS AND / OR NOTES. 3.0 WHERE MATERIALS REFERENCED ON DRAWINGS, OR NECESSARY TO COMPLETE THE WORK OF THIS CONTRACT ARE NOT SPECIFIED HEREIN, PROVIDE BEST QUALITY MATERIALS. WHERE MATERIALS ARE INTENDED TO MATCH EXISTING, PROVIDE CLOSEST POSSIBLE MATCH, SUBJECT TO OWNER'S APPROVAL. ALL ITEMS AND WORK ON DRAWINGS ARE NEW, UNLESS INDICATED EXISTING. ALL WORK WHICH HAS BEEN DAMAGED SHALL BE REPAIRED OR REPLACED AT NO COST TO THE OWNER. WHERE ITEMS CAN NOT BE REPAIRED TO A ""NEW CONDITION"", OR WHERE THE STRUCTURAL INTEGRITY HAS BEEN AFFECTED, ITEMS SHALL BE REPLACED AT NO COST TO THE OWNER. 4.0 CONTRACTOR IS RESPONSIBLE TO VERIFY ALL SITE, FIELD AND BUILDING CONDITIONS PRIOR TO SUBMITTING BIDS AND COMMENCING WORK. IF THERE ARE ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS, NOTIFY THE PROJECT MANAGER, WHO WILL REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER AND PROVIDE CLARIFICATION IN WRITING. 5.0 WHERE EXISTING CONSTRUCTION OR ITEMS HAVE BEEN INFILLED, REMOVED AND / OR DISTURBED FOR INSTALLATION OF NEW WORK, CAUSING THE EXPOSURE OF UNFINISHED AND/OR DAMAGED SURFACES RESULTING SURFACES AND INFILLED SURFACES SHALL BE RECONSTRUCTED WITH MATERIALS TO MATCH FINISHED AREAS. ALL ABANDONED OPENINGS (i.e. DUCT/PIPE REMOVALS, ETC.) AT WALLS, ROOF OR FLOOR TO BE INFILLED SOLID. 6.0 WORK IS REQUIRED IN VARIOUS PORTIONS OF THE FACILITY TO EXECUTE WORK OF OTHER TRADES (i.e. ELECTRICAL, MECHANICAL). ALTHOUGH NOT NECESSARILY SHOWN ON DRAWINGS, WORK IS REQUIRED IN THESE AREAS CONSISTING OF REMOVAL / REPLACEMENT OF CEILINGS, WALLS, FINISHES, PAVEMENT AND OTHER CONSTRUCTION AS NECESSARY TO PERFORM WORK AND RESTORE THESE SPACES OR AREAS TO ORIGINAL CONDITION. 7.0 GENERAL CONTRACTOR IS TO COORDINATE WORK OF ALL TRADES. SCHEDULE WORK PROGRESS THROUGHOUT THE ENTIRE PROJECT TO PREVENT CONFLICTS AND INTERFERENCES. OBTAIN ALL NECESSARY INFORMATION SUCH AS SIZES, LOCATIONS, TEMPLATES, LAYOUT, DIMENSIONS AND ALL OTHER INFORMATION NECESSARY FOR A PROPER AND WELL COORDINATED INSTALLATION. PRIOR TO INSTALLATION OF ITEMS, VERIFY AND CONFIRM WITH EACH CONTRACTOR EXACT LOCATION OF ALL ITEMS. 8.0 ALL PENETRATIONS (EXISTING OR NEW) THROUGH FLOORS AND FULL HEIGHT WALLS - IN AREA OF WORK TO BE FIRE STOPPED. ALL GAPS AND JOINTS AT RATED FLOORS, ROOFS AND WALLS TO BE FIRE & SMOKE STOPPED. GAPS AND JOINTS INCLUDE (BUT ARE NOT LIMITED TO) TOP OF WALL TO FLOOR OR ROOF DECK, WALL TO BEAMS, AND CONTROL OR EXPANSION JOINTS. FIRE STOPPING INCLUDES BOTH FORM OR PACKING MATERIAL AND THE FILL, VOID OR CAVITY MATERIAL. PROVIDE AND INSTALL LABELING REQUIRED BY CODE. LABELS SHALL INCLUDE PENETRATION TYPE WITH UL LISTING USED, MATERIAL USED, DATE INSTALL AND NAME OF INSTALLER. 9.0 JOBSITE WILL BE CLEANED DAILY AND DEBRIS REMOVED TO CONTAINERS OR TO VEHICLE WHICH WILL REMOVE DEBRIS FROM CAMPUS. CONTAINERS WILL BE REMOVED AS SOON AS FULL OR WHEN THE PROJECT HAS PROGRESSED TO A POINT THAT A CONTAINER IS NO LONGER REQUIRED. 10.0 CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL AREAS USED TO BRING SUPPLIES AND EQUIPMENT INTO THE PROJECT AREA. ANY DAMAGE TO AREAS OUTSIDE THE PROJECT AREA INCLUDING BUT NOT LIMITED TO THE LOBBY AND CORRIDOR SHALL BE REPAIRED AT NO COST TO THE OWNER. 1 04/30/2021 ISSUE FOR 100% DD REVIEW 2 05/11/2021 ISSUE FOR DEMOLITION PERMIT 3 06/01/2021 ISSUE FOR COORDINATED REVIEW 4 06/04/2021 ISSUE FOR CONSTRUCTION FFB 1 2 3* 11' - 7 1/2"16' - 9 1/4" 2 1 4 5 5 5 5 A B B ACCCC 5WORK LIMITS NOTE:* INDICATES ADDITIONAL DEMO SCOPE ADDED SINCE 5/11/2021 DEMO PACKAGE 6 6 6 8 8 8 6 6 7 9 NOTE:REFER TO ELECTRICAL DRAWINGS FOR MORE INFORMATION ON REMAINING ELECTRICAL REMOVALS, SHOWN AS DEMO, ADDED SINCE 5/11/2021 DEMO PACKAGE. 261 261B 261A 261C 260 260A 260B 200SD V.I.F.13' - 8" +/-10*10* 11*CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 921 UNIVERSITY AVE ITHACA, NEW YORK 14850 SIBLEY HALL IT SOLUTIONS RENOVATIONS A-101 13291868 PARTIAL SECOND FLOOR DEMOLITION PLAN J. COOLBAUGH JGC 2004 JUNE 4, 2021 A-101 KEYED DEMOLITION NOTES 1 REMOVE EXISTING WALL FROM FLOOR TO BOTTOM OF FLOOR DECK ABOVE. 2 CAREFULLY REMOVE AND SALVAGE EXISTING STOREFRONT SYSTEM FOR REINSTALLATION. LETTERS CORRESPOND WITH LOCATIONS TO BE REINSTALLED. REFER TO RENOVATION PLAN. 3* REMOVE EXISTING DOOR, FRAME AND HARDWARE. TURN OVER TO OWNER. 4 REMOVE EXISTING WALL FROM FLOOR TO 10' - 0" +/-. MATCH SOFFIT ABOVE STOREFRONT. 5 EXISTING FLOORING TO BE ABATED BY LICENSED CONTRACTOR. 6 DISCONNECT AND REMOVE DUPLEX RECEPTACLES. REMOVE EXISTING CONDUIT AND CIRCUITRY BACK TO SOURCE OR NEAREST JUNCTION BOX. MAINTAIN CIRCUIT CONTINUITY FOR OTHER DEVICES ON SAME CIRCUIT. 7 DISCONNECT AND REMOVE EXISTING LIGHT SWITCH. REMOVE EXISTING CONDUIT AND CIRCUITRY BACK TO SOURCE. 8 DISCONNECT AND REMOVE EXISTING DATA OUTLETS. REMOVE EXISTING CONDUIT AND CABLING BACK TO SOURCE. 9 REMOVE EXISTING DOOR, FRAME, AND HARDWARE. 10* REMOVE EXISTING SOFFIT AND FRAMING ABOVE STOREFRONT/ BELOW BEAM. 11* REMOVE EXISTING CORK BOARD FROM ENTIRE WALL. PATCH WALL AS REQIRED. # 0' 2' 4' 8' SCALE: 1/4"=1'-0" SCALE:1/4" = 1'-0"1 PARTIAL SECOND FLOOR DEMOLITION PLAN 1 04/30/2021 ISSUE FOR 100% DD REVIEW 2 05/11/2021 ISSUE FOR DEMOLITION PERMIT 3 06/01/2021 ISSUE FOR COORDINATED REVIEW 4 06/04/2021 ISSUE FOR CONSTRUCTION NOTE:* INDICATES ADDITIONAL DEMO SCOPE ADDED SINCE 5/11/2021 DEMO PACKAGE. 262A 262B 262C 261C 261B 261 261A 200SD 260 260B 260A 250 10' - 9"12' - 4 1/8"9' - 11 7/8"15' - 2 3/8"15' - 0"9' - 0"16' - 1 1/4"CLR5' - 0"5' - 7 3/4" 261B 262C262B262A 1 3 1 1 1 11 1 2 B B D2 D1 A C C A333 4 4 5 6 EXISITNG STEEL BEAM ABOVE (TYP) 7 88 8 8 8 8 8 9 99 9 A-102 4 4"9' - 0"9' - 0" +/- WALL HEIGHT = 11' - 0" THIS LOCATION ONLY 18' - 4 5/8" 10 262 262 261C 4"10' - 3"4' - 8"6' - 2 1/2"4' - 8"4"4' - 8"7 A-102 6 11 11 11 11 11 11 CLR.3' - 0"V.I.F.7' - 8" +/-CLR.3' - 0"20' - 4 5/8" 14 13 13 12 12 WORK LIMITS 8 FURNITURE SHOWN IN VIEW BY OWNER OWNER PROVIDED DOUBLE EGRESS COUNTER GATEMIN.6"15 15 4 7 3 A-102 2 A-102 (2) 3 5/8" X 3 5/8" BOX COLUMNS - FULL HEIGHT 3 5/8" BOX HEADER 16 1 A-102 17 1717 13 13 4"4' - 8" 2" 1' - 2" 2" 3' - 0"2"2"2' - 8"2"2' - 10 3/4"2"3' - 11 1/4"7' - 0"10' - 0"261 261B 261C 2"3' - 0"2" 3' - 4"7' - 0"2"7' - 2"OWNER SUPPLIED DOOR, FRAME AND HARDWARE. EXISTING FLOOR JOISTS TO REMAIN EXISTING COLUMN TO REMAIN EXISTING BEAM TO REMAIN 6' - 2 1/2"4' - 8"4' - 8"10' - 3"10' - 0"262C 262B 262A OWNER SUPPLIED DOOR AND HARDWARE. RECONFIGURED STOREFRONT FRAME. B BACCA REINSTALL DOORS IN RECONFIGURED FRAME D1 D2 RECONFIGURED STOREFRONT FRAME. EXISTING BEAM TO REMAIN EXISTING FLOOR JOISTS TO REMAIN EXISTING COLUMN TO REMAIN 9' - 0"2"3' - 9 1/4"2"5' - 8 3/4"2"2"2' - 6" 2" 1' - 4" 2" 3' - 0" 2" 1' - 4" 2" 262 T.O.W. = 11' - 0"OWNER SUPPLIED DOOR, FRAME AND HARDWARE. EXISTING FLOOR JOISTS TO REMAIN TRACK PROVIDED BY OWNER MIN. 6" PROVIDE L8" x 8" x 1/2" x 0'-8" ANGLE TO SUPPORT TRACK. SECURE VERTICAL LEG TO BRICK WALL WITH (2) 3/8" THREADED ROD (3 1/2" EMBED) SET IN EPOXY ADHESIVE (AC100+ BY POWERS). LAYOUT SO ANCHORS ARE IN MORTAR JOINT, SPACED 6" APART, MIN 6" FROM EDGE OF MASONRY WALL AND MAX 2 1/2" FROM TOP OF ANGLE (TYP FOUR LOCATIONS). PAINT ALL STEEL TO MATCH WALL. EXISTING WALL CLHEIGHTVERIFY TRACK PROVIDED BY OWNER PROVIDE L8" x 8" x 1/2" x 0'-5" ANGLE SECURED WITH (2) 1/2" DIAMETER THROUGH BOLTS. EACH THROUGH BOLT IS TO BE SECURED TO 3 1/2" x 6" BOX COLUMN AND 12 GA BENT PLATE EXTENDING FULL HEIGHT OF WALL (TYP THREE LOCATIONS) PAINT ALL STEEL TO MATCH WALL. PROVIDE 6" -18 GA. METAL STUDS @ 16" O.C. . PROVIDE 16 GA. DEFLECTION TRACK WITH 2" LEG AT TOP OF WALL. CL 1/2" PLYWOOD EACH SIDE 12 GA. BEND PLATE WITH 2" LEGS AROUND 6" METAL STUDS EACH SIDE 1/2" PLYWOOD 5/8" GWB EACH SIDE -PROVIDE J BEADS AT PLYWOOD/ STEEL -TAPE, SPACKLE, PRIME, & PAINT (2 COATS) A A DETAIL 'A' 5/8" GWB - TAPE, SPACKLE, PRIME, & PAINT (2 COATS) EXISTING JOIST (2) 2" x 8" WOOD BLOCKING SECURED TO JOIST WITH 14 GA. HU HEAVY FACE MOUNT JOIST HANGER BY SIMPSON. PAINT TO MATCH CEILING PROVIDE SIMPSON SIDE CLIP (SCS62-5/97-KT25) CENTERED ON COLUMN WHICH ALLOWS FOR VERTICAL DEFLECTION (2) 3 5/8" x 3 5/8" BOX COLUMNS EXISTING FLOOR TOP OF 11' -0" HIGH WALL FINISH COLUMNS WITH GYPSUM WALLBOARD (ALL 4 SIDES). TAPE, SPACKLE, PRIME, & PAINT (2 COATS). PROVIDE J BEAD AT TOP OF GWB CORNE LL U N IV E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 921 UNIVERSITY AVE ITHACA, NEW YORK 14850 SIBLEY HALL IT SOLUTIONS RENOVATIONS A-102 13291868 PARTIAL SECOND FLOOR RENOVATION PLAN J. COOLBAUGH JGC 2004 JUNE 4, 2021 0' 2' 4' 8' SCALE: 1/4"=1'-0" A-102 KEYED RENOVATION NOTES 1 PROVIDE 3 5/8" - 18 GA. METAL STUDS @ 16" O.C. WITH (1) LAYER OF 5/8" GWB ON EACH SIDE AND 3 1/2" SOUND BATT. TAPE, SPACKLE, PRIME, & PAINT (2 COATS). PROVIDE 16 GA. DEFLECTION TRACK WITH 2" LEG AT TOP OF WALL. 2 PROVIDE 3 5/8" - 18 GA. METAL STUDS @ 16" O.C. WITH (2) LAYER OF 5/8" TYPE X GWB ON EACH SIDE (2 HR RATED WALL) AND 3 1/2" SOUND BATT. TAPE, SPACKLE, PRIME, & PAINT (2 COATS). PROVIDE 16 GA. DEFLECTION TRACK WITH 2" LEG AT TOP OF WALL. 3 REINSTALL STOREFRONT. "LETTER" STANDS FOR EXISTING PANEL TO BE INSTALLED. 4 PATCH, REPAIR AND PAINT WALLS WHERE EXISTING WALL WAS REMOVED. 5 INSTALL GATE AND STEEL TRACK, SUPPLIED BY OWNER. 6 PROVIDE 6" - 18 GA. METAL STUDS @ 16" O.C. WITH 5/8" GWB - (1) LAYER ON THE WEST SIDE AND (2) LAYERS ON THE EAST SIDE. TAPE, SPACKLE, PRIME, & PAINT (2 COATS). PROVIDE 16 GA. DEFLECTION TRACK WITH 2" LEG AT TOP OF WALL. 7 PROVIDE THREADED ROD HANGERS AT 24 IN SPACING, HANG FROM FLOOR JOISTS WITH L BRACKETS. 8 PROVIDE NEW FLOORING AS SELECTED BY OWNER. 9 PATCH, REPAIR AND PAINT CEILING WHERE EXISTING WALLS WAS REMOVED. 10 PROVIDE 3 5/8" - 18 GA. METAL STUDS @ 16" O.C. WITH (1) LAYER OF 5/8" GWB ON EACH SIDE. TAPE, SPACKLE, PRIME, & PAINT (2 COATS). 11 PATCH, REPAIR AND INFILL ANY FLOOR OPENINGS WHERE EXISTING EQUIPMENT WAS REMOVED. PROVIDE INFILL TO MATCH EXISTING FLOOR HEIGHT. MAINTAIN FLOOR FIRE RATING. 12 PROVIDE 3 5/8" - 18 GA. METAL STUD BOX HEADER (TYP. AT ALL DOORS/ WINDOWS). 13 PROVIDE 3 5/8" - 18 GA. METAL STUD BOX HEADER LAID FLAT TO SUPPORT THE STOREFRONT SYSTEM. 14 PROVIDE 3 5/8" - 16 GA. METAL STUD BOX HEADER FULL LENGTH OF LOW HEIGHT WALL . 15 PROVIDE L8" x 8" x 1/2" x 0'-8" ANGLE TO SUPPORT TRACK. SECURE VERTICAL LEG TO BRICK WALL WITH (2) 3/8" THREADED ROD (3 1/2" EMBED) SET IN EPOXY ADHESIVE (AC100+ BY POWERS). LAYOUT SO ANCHORS ARE IN MORTAR JOINT, SPACED 6" APART, MIN 6" FROM EDGE OF MASONRY WALL AND MAX 2 1/2" FROM TOP OF ANGLE (TYP FOUR LOCATIONS). PAINT ALL STEEL TO MATCH WALL. 16 PROVIDE L8" x 8" x 1/2" x 0'-5" ANGLE SECURED WITH (2) 1/2" DIAMETER THROUGH BOLTS. EACH THROUGH BOLT IS TO BE SECURED TO 3 1/2" x 6" BOX COLUMN AND 12 GA BENT PLATE EXTENDING FULL HEIGHT OF WALL (TYP THREE LOCATIONS) PAINT ALL STEEL TO MATCH WALL. 17 3 5/8" X 6" BOX COLUMN - FULL HEIGHT OR TO UNDERSIDE OF EXISTING BEAM. WHERE THE TOP OF BOX COLUMN ALIGNS DIRECTLY BELOW AN EXISTING STEEL BEAM OR WOOD FLOOR JOIST, SECURE COLUMN WITH (2) HWDC5.25 TOP OF WALL CONNECTORS BY SIMPSON SECURED DIRECTLY TO THE BOTTOM OF THE FLOOR MEMBER. HOLD TOP OF COLUMN ONE INCH BELOW FLOOR MEMBER AND INSTALL PER MANUFACTURER INSTRUCTIONS TO ALLOW VERTICAL DEFLECTION OF FLOOR MEMBER. ADDITIONALLY, WHEN INSTALLING SIMPSON HWDC5.25 ATTACHMENT TO FLOOR MEMBER, PROVIDE BLOCKING ON BOTH SIDES OF EXISTING WOOD FLOOR JOISTS AND CONFIRM STEEL BEAM HAS A TOP FLANGE THAT IS POSITIVELY ATTACHED THE FLOOR FRAMING IT IS SUPPORTING. # SCALE:1/4" = 1'-0"5 PARTIAL SECOND FLOOR RENOVATION PLAN A-102 GENERAL RENOVATION NOTES 1.0 PATCH FLOORS WHERE WALLS HAVE BEEN DEMOLISHED TO MATCH EXISTING SLAB ELEVATION AND PREP FOR NEW FLOOR FINISH. NEW FLOOR FINISHES TO BE PROVIDE BY OWNER. 2.0 ALL DOOR INFILLS SHALL BE COMPLETED WITH LIKE MATERIALS THAT MATCH EXISTING WALL COMPONENTS. REPAIR ADJACENT EXISTING WALL AS REQUIRED AND PREPARE AREA FOR NEW FINISH. 3.0 ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 4.0 ALL FINISHES ARE TO BE SELECTED BY OWNER. 5.0 ALL WALLS IN WORK AREA (EXISTING AND NEW) ARE TO BE PAINTED. COLOR AS SELECTED BY OWNER. SCALE:1/4" = 1'-0"7 EAST DOOR ELEVATION SCALE:1/4" = 1'-0"6 OFFICE DOOR ELEVATIONS SCALE:1/4" = 1'-0"4 SOUTH DOOR ELEVATION SCALE:1 1/2" = 1'-0"3 TRACK WALL BRACKET AT BRICK WALL SCALE:1 1/2" = 1'-0"2 TRACK WALL BRACKET AT STUD WALL SCALE:1 1/2" = 1'-0"1 BOX COLUMN SUPPORT 1 04/30/2021 ISSUE FOR 100% DD REVIEW 2 05/11/2021 ISSUE FOR DEMOLITION PERMIT 3 06/01/2021 ISSUE FOR COORDINATED REVIEW 4 06/04/2021 ISSUE FOR CONSTRUCTION SCALE: 1-1/2"=1'-0" 6" 1'0" 3" CORN E LL U N I V E RSI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 921 UNIVERSITY AVE ITHACA, NEW YORK 14850 SIBLEY HALL IT SOLUTIONS RENOVATIONS FP-001 13291868 FIRE PROTECTION E. LEPORE TRF 2004 JUNE 4, 2021 FIRE PROTECTION GENERAL NOTES 1.0 IT IS THE INTENT OF THESE DRAWINGS TO PROVIDE MODIFICATIONS TO THE WET SPRINKLER FIRE PROTECTION SYSTEMS FOR THE PROTECTION OF THE SIBLEY HALL. 2.0 PRIOR TO ALTERATIONS, THE SPRINKLER CONTRACTOR SHALL FIELD VERIFY EXTENT OF ALTERATION AND NEW WORK, WITH REGARD TO EXISTING CONDITIONS AT PIPE PENETRATIONS THROUGH FLOORS, WALLS, CEILINGS AND SOFFITS. 3.0 ALL SPRINKLER COMPONENTS SHALL BE UNDERWRITER'S LABORATORIES (UL) AND FACTORY MUTUAL (FM) APPROVED. 4.0 NEW SPRINKLER SYSTEM PIPING SHALL BE INSTALLED IN EXPOSED CEILING AREAS AS SHOWN ON PLANS. PIPING AND HANGER ASSEMBLIES SHALL BE PAINTED, TO MATCH SURROUNDINGS.. 5.0 THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE ONLY THE GENERAL ARRANGEMENT OF THE ITEMS INCLUDED IN THE FIRE PROTECTION WORK. AS SUCH, CONTRACTOR SHALL PROVIDE A COMPLETE SPRINKLER SYSTEM IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF FM GLOBAL STANDARDS, THE NFPA 13-INSTALLATION OF FIRE PROTECTION SYSTEMS, THE NEW YORK STATE BUILDING CODES, THE NEW YORK STATE FIRE CODES, LOCAL CODES, AND GOVERNING AUTHORITIES. THE DESIGN OF FIRE PROTECTION SYSTEMS TO WITHSTAND SEISMIC EVENTS SHALL BE IN ACCORDANCE WITH THE CRITERIA DEVELOPED BY THE NFPA. 6.0 CONTRACTOR SHALL REQUEST SPRINKLER SYSTEM SHUTDOWNS THROUGH CORNELL CUSTOMER SERVICE (607.255.5322) A MINIMUM OF TEN (10) DAYS PRIOR TO THE SHUTDOWN DATE. THE CONTRACTOR SHALL BEAR THE COST OF THE UTILITY SHUTDOWN. NOTIFY THE OWNER'S REPRESENTATIVE TO COORDINATE BUILDING FUNCTIONS WITH THE BUILDING COORDINATOR. 7.0 COORDINATE THE EXACT LOCATION OF SPRINKLERS, EQUIPMENT, AND DEVICES WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL AND ALL OTHER TRADES DRAWINGS PRIOR TO ROUGH-IN AND INSTALLATION. 8.0 SPRINKLER PIPING SHALL BE ARRANGED TO DRAIN THROUGH THE MAIN DRAIN VALVE WHENEVER PRACTICAL. ALL TRAPPED SECTIONS OF PIPE, EXCEPT THOSE SUPPLYING A SINGLE SPRINKLER, SHALL BE PROVIDED WITH A DRUM-DRIP ASSEMBLY. 9.0 PENETRATIONS THROUGH CONCRETE FLOORS AND WALLS SHALL BE MADE WITH GALVANIZED PIPE SLEEVES. ALL PENETRATIONS SHALL CONTAIN FIRE STOPPING WITH A FIRE RATING EQUAL TO THAT OF THE AREA BEING PENETRATED. 10.0 SPRINKLER PIPING SHALL BE LABELED. 11.0 AFTER ALL WORK HAS BEEN COMPLETED, ACCEPTANCE TESTING SHALL BE SCHEDULED THROUGH EH&S, AND SHALL BE WITNESSED BY EH&S AND CITY OF ITHACA REPRESENTATIVES. 12.0 HYDROSTATIC TEST SHALL BE PERFORMED AT 200 PSI (OR 50 PSI ABOVE STATIC PRESSURE IF SYSTEM PRESSURE IS ABOVE 150 PSI), FOR A PERIOD OF 2-HOURS. A REPRESENTATIVE OF ENVIRONMENTAL HEALTH AND SAFETY SHALL WITNESS HYDROSTATIC TESTING OF THE NEW PIPING INSTALLATIONS AND ALTERATIONS. THE AUTHORITY HAVING JURISDICTION (ITHACA FIRE DEPARTMENT) REQUIRES THAT ONE OF THEIR REPRESENTATIVES WITNESSES HYDROSTATIC TESTING AND FLUSHING. ADVANCE NOTICE AND SCHEDULING IS REQUIRED THROUGH EH&S. 13.0 ANY FIRESTOPPING DISTURBED DURING THE COURSE OF WORK SHALL BE REPAIRED TO MAINTAIN A 2-HOUR FIRE RATING. 14.0 IF ANY PORTION OF THE SPRINKLER SYSTEM WILL BE OUT OF SERVICE FOR MORE THAN ONE WORKDAY, PROVIDE TEMPORARY HEAT DETECTORS IN THE AFFECTED ROOMS. AFTER INSTALLATION AND INTEGRATION INTO EXISTING FIRE ALARM SYSTEM, DETECTORS WILL NEED TO BE TESTED AND WITNESSED BY CORNELL EH&S BEFORE CONSTRUCTION CAN COMMENCE. THIS DIRECTIVE IS BEING MADE BASED ON THE UNDERSTANDING THAT THE SPRINKLER SYSTEM SERVING THE REST OF THE ZONE (FLOOR) WILL BE PUT BACK INTO SERVICE AT THE END OF EACH WORKDAY. FIRE PROTECTION SCOPE OF WORK 1.0 PROVIDE MODIFICATIONS TO EXISTING SPRINKLER HEAD LOCATIONS AS REQUIRED TO ACCOMODATE SPACE RENOVATIONS. 2.0 SELECTIVE DEMOLITION OF EXISTING SPRINKLER PIPING, HEADS, AND ACCESSORIES. 3.0 PROVIDE UPRIGHT SPRINKLERS, PIPING, AND ACCESSORIES TO ENSURE ADEQUATE SPRINKLER COVERAGE IN THE RENOVATION SPACES. 4.0 PROVIDE FLUSHING VALVES TO ENABLE FUTURE SPRINKLER SYSTEM MAINTENANCE. SPRINKLER SCHEDULE SPRINKLER TYPE/TAG SERVES MANF BOD MODEL BOD (SIN) RESPONSE ORIFICE (IN) K-FACTOR TEMPERATURE RATING (DEG F)CONSTRUCTION FINISH ESCUTCHEON UPRIGHT/US-1 SUITE 216 RELIABLE F1FR56 (RA1425) QUICK 1/2 5.6 155 BRASS CHROME F1 - CHROME FIRE PROTECTION PIPING SCHEDULE PIPE SERVICE ABBREVIATION PIPE SIZE MATERIAL FITTINGS FINISH WET SPRINKLER WSP ALL SIZES ASTM A 53 TYPE F STEEL, TYPE F, SCHEDULE 40 BLACK, GRADE A CAST OR MALLEABLE IRON THREADED PAINT GENERAL DRAWING SYMBOLOGY DEMOLISHED WORK EXISTING PIPING TO REMAIN EXISTING TO REMAIN EXISTING WORK TO REMAIN NEW WORK POINT OF CONNECTION POINT OF DISCONNECTION PIPING ACCESSORIES SCHEDULE AND SPECIFICATIONS TAG DEVICE BOD MANUFACTURER MODEL PRESSURE RATING SPECIFICATIONS V-1 FLUSHING BALL VALVE NIBCO KT-585-70-UL 300 PSIG WWP MSS SP-110, 2-PIECE, FULL PORT, BRONZE BODY, BRASS BALL, BRONZE STEM, PTFE SEAT, UL & FM APPROVED. 1 04/30/2021 ISSUE FOR 100% DD REVIEW 2 05/11/2021 ISSUE FOR DEMOLITION PERMIT 3 06/01/2021 ISSUE FOR COORDINATED REVIEW 4 06/04/2021 ISSUE FOR CONSTRUCTION SPECS 1. PIPE NIPPLES: SAME QUALITY, MATERIAL, CLASS AS PIPING. CLOSE NIPPLES ARE NOT PERMITTED. 2. DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE GENERAL LOCATION AND ARRANGEMENT OF PIPING. CONTRACTOR TO FIELD MEASURE FOR OBSTRUCTIONS, LOCATE PIPING AND SPRINKLERS, IDENTIFY OFFSET, AND PRODUCE CAD SHOPE DRAWINGS FOR APPROVAL. DEVIATIONS FROM APPROVED WORKING PLANS REQUIRE WRITTEN APPROVAL FROM AUTHORITIES HAVING JURISDICTION. 3. USE APPROVED FITTINGS TO MAKE CHANGES IN DIRECTION, BRANCH TAKEOFFS FROM MAINS, AND REDUCTIONS IN PIPE SIZE. 4. PROVIDE DRAINS FOR COMPLETE SYSTEM DRAINAGE, PER NFPA 5. HANGERS AND SUPPORTS: COMPLY WITH NFPA 13 AND 14 FOR HANGER MATERIALS 6. PAINT ALL PIPING, WHEN EXPOSED TO VIEW. MATCH EXISTING PAINT COLOR. 7. PROVIDE PIPE LABLES AND DIRECTIONAL ARROWS ON ALL NEW PIPING SYSTEMS. LABELS SHALL BE PRINTED PLASTIC WITH CONTACT-TYPE, PERMANENT ADHESIVE BACKING. 8. CLEAN SYSTEM PER NFPA 13. SPECS 1. ALL VALVES SHALL BE UL LISTED AND FM APPROVED, WITH MINIMUM 175 PSIG NONSHOCK WORKING PRESSURE. 1" SP 1"1" 1" SP 1 1/4" SP 1 1/4"1 1/4" SP2" SP 1" SP 1" SP 1"1 1/4" 261A Room 261 Room 261C Room 261B Room 200SD Room 260 Room 260B Room 260A Room 250 Room 4" SP SUPPLY MAIN (E) 2" ZONE VALVE (E) 2" SP SUPPLY (E) FLOW SWITCH (E) 3" SP SUPPLY TO RENOVATION AREA (E) 3" SP SUPPLY DN TO FLOOR BELOW (E) 3" SP SUPPLY TO ADJACENT SPACES (E) 2" SP SUPPLY DN TO FLOOR BELOW (E) 11 1 1 1" SP 1 1/2" SP 2" SP 2" SP 2" SP2" SP2 2 22 2 2 2 2 2 1 1/4" SP 1" SP1" SP 1" SP 1" SP 1 1/4" SP1 1/4" SP 2 1/2" SP 2" SP UPRIGHT SP (E) PENDENT SP (E) FLUSHING VALVE (E) 2 4" SP SUPPLY MAIN (E)2 1/2" SP2" SP 2" SP 1 1/4" SP1 1/4" SP 1" SP 1" SP 2" ZONE VALVE (E) 2" SP SUPPLY (E) FLOW SWITCH (E)2 1/2" SP1" SP 1 1/2" SP 1 1/4" SP 1" SP 1" SP 1" SP 1" SP 1 1/2" SP 1 1/2" SP 2" SP 2" SP 2" SP2" SP2" SP2" SP2" SP 2 1/2" SP1" SP 1" SP 1" SP1" SP 1" SP 1 1/4" SP 1 1/4" SP 1 1/4" SP2 1/2" SP 3" SP SUPPLY TO RENOVATION AREA (E) 3" SP SUPPLY DN TO FLOOR BELOW (E) 3" SP SUPPLY TO ADJACENT SPACES (E) 2" SP SUPPLY DN TO FLOOR BELOW (E) 262C Room 262B Room 262A Room 260 Room 260B Room260A Room 200SD Room 261 Room 261C Room 261B Room 261A Room 250 Room 1 1/2" SP 1 1/2" SP 1 1/4" SP 1" SP 1" SP1" SP1" SP1" SP1 1/4" SP 1 1/2" SP1 1/2" SP 2" SP1" SP1 1 1 1 2 2 2 V-1 V-1 V-1 US-1 US-1 US-1 US-1 US-1 US-1 US-1 US-1US-1 US-1 UPRIGHT SP (E) PENDENT SP (E) 1" SP 2 US-1 V-1 1 CORN E LL U N I V E RSI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 921 UNIVERSITY AVE ITHACA, NEW YORK 14850 SIBLEY HALL IT SOLUTIONS RENOVATIONS FP-101 13291868 PARTIAL SECOND FLOOR PLAN E. LEPORE TRF 2004 JUNE 4, 2021 SCALE:3/16" = 1'-0"1 PARTIAL SECOND FLOOR FIRE PROTECTION DEMOLITION PLAN SCALE:3/16" = 1'-0"2 PARTIAL SECOND FLOOR FIRE PROTECTION RENOVATION PLAN FP-101 KEYED DEMOLITION NOTES 1 EXISTING SPRINKLERS TO REMAIN AT WINDOWS TO MAINTAIN EXISTING FIRE BARRIER AND 2 HOUR WALL RATING. THIS SYSTEM IS MONITORED ON A SEPERATE SPRINKLER ZONE AND SHALL NOT BE MODIFIED AS PART OF THE RENOVATIONS. 2 DISCONNECT AND REMOVE SPRINKLER BRANCH PIPING, CONNECTED UPRIGHT HEADS, AND FLUSHING VALVE. REFER TO 2/FP-101 FOR RECONNECTION. FP-101 KEYED RENOVATION NOTES 1 CONNECT TO EXISTING SPRINKLER DISTRIBUTION PIPING AS REQUIRED TO PROVIDE PIPING AND SPRINKLER COVERAGE IN LOCATIONS SHOWN. 2 PROVIDE 1" FLUSHING VALVE AND CAP AT THE END OF THE SPRINKLER BRANCH LINE FOR FUTURE MAINTENANCE. # # 1 04/30/2021 ISSUE FOR 100% DD REVIEW 2 05/11/2021 ISSUE FOR DEMOLITION PERMIT 3 06/01/2021 ISSUE FOR COORDINATED REVIEW 4 06/04/2021 ISSUE FOR CONSTRUCTION CORN E LL U N I V E RSI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 921 UNIVERSITY AVE ITHACA, NEW YORK 14850 SIBLEY HALL IT SOLUTIONS RENOVATIONS M-001 13291868 MECHANICAL GENERAL NOTES AND SYMBOL LEGENDS E. LEPORE JD 2004 JUNE 4, 2021 MECHANICAL ABBREVIATIONS BCU BLOWER COIL UNIT CHWR CHILLED WATER RETURN CHWS CHILLED WATER SUPPLY CC CLEAN CONDENSATE CO CLEAN OUT CS CLEAN STEAM CD CONDENSATE DRAIN CR CONDENSATE RETURN EA EXHAUST AIR EAG EXHAUST AIR GRILLE FD FIRE DAMPER GWR GLYCOL HEATING RETURN GWS GLYCOL HEATING SUPPLY HPR HIGH PRESSURE STEAM RETURN HPS HIGH PRESSURE STEAM SUPPLY HWR HOT WATER HEATING RETURN HWS HOT WATER HEATING SUPPLY LPC LOW PRESSURE CONDENSATE LPS LOW PRESSURE STEAM MU MAKE UP WATER MPC MEDIUM PRESSURE CONDENSATE MPS MEDIUM PRESSURE STEAM NG NATURAL GAS PCWR PROCESS CHILLED WATER RETURN PCWS PROCESS CHILLED WATER SUPPLY HG REFRIGERANT HOT GAS RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION RAG RETURN AIR GRILLE SA SUPPLY AIR SAD SUPPLY AIR DIFFUSER VD VOLUME DAMPER MECHANICAL SYMBOLOGY AIRFLOW BACKFLOW PREVENTER BALANCE VALVE BALL VALVE BOTTOM PIPE CONNECTION BUTTERFLY VALVE CAP OR PLUG CHECK VALVE CIRCULATING PUMP DIRECTION OF FLOW DUCT AIRFLOW DUCT DOWN (EXHAUST OR RETURN) DUCT DOWN (SUPPLY) FIRE AND SMOKE DAMPER IN DUCT FIRE DAMPER IN DUCT FLANGE CONNECTION FLEX CONNECTOR FLEXIBLE CONNECTION FLEXIBLE DUCT FLOW METER FLOW SWITCH FUSIBLE LINK VALVE GLOBE VALVE MANUAL AIRVENT ORIFICE METER PIPE DOWN PIPE UP PIPING REDUCER (CONCENTRIC) PIPING REDUCER (ECCENTRIC) PRESSURE GAUGE PRESSURE OR TEMPERATURE PETES PLUG PRESSURE REDUCING VALVE PRESSURE SWITCH RECTANGULAR ELBOW RECTANGULAR ELBOW WITH TURNING VANES RELIEF VALVE SMOKE DAMPER IN DUCT SOLENOID VALVE STANDARD BRANCH DUCT STEAM TRAP STRAINER (DUPLEX) STRAINER WITH BLOWDOWN VALVE AND CAP SUPPLY THROUGH NEXT FLOOR OR ROOF TEMPERATURE WELL THERMOMETER THERMOMETER (DIAL) TOP PIPE CONNECTION TRIPLE DUTY VALVE UNION CONNECTION VACUUM BREAKER VOLUME DAMPER IN DUCT CONTROL SYMBOLOGY 2-WAY CONTROL VALVE, DIGITAL 2-WAY CONTROL VALVE, PNEUMATIC 3-WAY CONTROL VALVE, DIGITAL 3-WAY CONTROL VALVE, PNEUMATIC ADDRESSABLE OUTPUT MODULE (FIRE ALARM INTERFACE) AIRFLOW CONTROL VALVE (VENTURI OR VORTEX SHEDDING) AVERAGING SENSOR BINARY POINT BUTTERFLY CONTROL DAMPER CARBON DIOXIDE SENSOR CONDENSATE SENSOR CURRENT SENSOR DEW-POINT SENSOR DIFFERENTIAL PRESSURE SENSOR DIFFERENTIAL PRESSURE SENSOR ELECTRIC TO PNEUMATIC SWITCH ELECTRIC TO PNEUMATIC TRANSDUCER END SWITCH FLOW ELEMENT (METER) FLOW SENSOR HIGH LEVEL SWITCH HUMIDSTAT SENSOR LIQUID IMERSION TEMPERATURE SENSOR LOW LEVEL SWITCH MODULATING MOTOR MOTOR STARTER NETWORK COMMUNICATION POINT, BACnet MSTP OCCUPANCY SENSOR OPEN/CLOSE OPPOSED BLADE CONTROL DAMPER PARALLEL BLADE CONTROL DAMPER PNEUMATIC THERMOSTAT PRESSURE SENSOR PRESSURE SWITCH RELATIVE HUMIDITY SENSOR RELAY ROOM TEMPERATURE SENSOR WITH ADJUSTABLE THERMOSTAT ROOM TEMPERATURE SENSOR WITH OCCUPANCY OVERRIDE ROOM TEMPERATURE SENSOR WITH ON/OFF SWITCH ROOM TEMPERATURE SENSOR WITH VISUAL DISPLAY ROTATION DETECTOR SINGLE POINT SENSOR SMOKE DETECTOR SPEED COMMAND START/STOP STATIC PRESSURE SENSOR SWITCH TEMPERATURE SENSOR TEMPERATURE SENSOR TEMPERATURE SENSOR WITH ADJUSTABLE SETPOINT GENERAL DRAWING SYMBOLOGY DEMOLISHED WORK EXISTING PIPING TO REMAIN EXISTING TO REMAIN EXISTING WORK TO REMAIN NEW WORK POINT OF CONNECTION POINT OF DISCONNECTION CONTROL ABBREVIATIONS AI ANALOG INPUT AO ANALOG OUTPUT AV ANALOG VALUE BI BINARY INPUT BO BINARY OUTPUT BV BINARY VALUE F.L. FAIL LAST N.C. NORMALLY CLOSED N.O. NORMALLY OPEN VFD VARIABLE FREQUENCY DRIVE MECHANICAL SCOPE OF WORK 1.0 SELECTIVE DEMOLITION OF EXISTING SECOND FLOOR STEAM RADIATORS AND FLOOR TRANSFER AIR DUCT. 2.0 INSTALL NEW PERIMETER HOT WATER RADIATORS ON THE SECOND FLOOR WITH ASSOCIATED DIGITAL CONTROL. 3.0 INSTALL NEW HOT WATER CIRCULATION PUMP IN THE BASEMENT AND ASSOCIATED PIPING TO SUPPORT THE NEW RADIATORS ON THE SECOND FLOOR. PROVIDE WITH DIGITAL CONTROL, PROGRAMMED TO OPERATE WITH THE EXISTING HOT WATER HEAT EXCHANGER. 4.0 PROVIDE CHW, COOLING ONLY FAN COIL UNIT (FCU-261D) ON THE SECOND FLOOR DEDICATED TO COOLING (1) IT SERVER RACK, APPROXIMATELY 12,000 BTU/HR. 5.0 RELOCATE THE SECOND FLOOR TRANSFER AIR DUCT. MECHANICAL GENERAL NOTES 1.0 ALL DUCT DIMENSIONS INDICATED ARE IN INCHES, AND ARE INSIDE FREE AND CLEAR DIMENSIONS. 2.0 PNEUMATIC TERMINATIONS: IF COPPER: DEMO BACK TO MAIN AND PROVIDED SOLDERED END CAP IF POLY: DEMO BACK TO MAIN AND PROVIDE BRASS PLUG DO NOT USE SHEETMETAL SCREW OR BEND OVER END OF COPPER TUBE. 3.0 INSTALL EQUIPMENT TO ENSURE PROPER ACCESS TO CONTROL DEVICES AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE AND REPAIR. EQUIPMENT THAT IS NOT INSTALLED WITH THIS REQUIREMENT IN MIND SHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIES ARE CORRECTED. 4.0 ALL SYSTEM TESTING SHALL BE CONDUCTED PRIOR TO INSULATION, FIREPROOFING, AND ENCLOSURE IN SHAFTS. ANY RESTORATION WORK REQUIRED AS A RESULT OF DISTURBING FINISHES OR STRUCTURE IN ORDER TO ACCESS SYSTEMS REQUIRING REPAIR SHALL BE AT NO COST TO THE UNIVERSITY. 5.0 CUTTING AND PATCHING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, FITTING, AND PATCHING TO COMPLETE THE WORK. WHERE EXISTING CONSTRUCTION IS REMOVED, CAUSING AN EXPOSURE OF UNFINISHED AND/OR DAMAGED SURFACES, RESULTING SURFACES SHALL BE RECONSTRUCTED WITH MATERIALS TO MATCH FINISHED AREAS. 6.0 ANY FIRESTOPPING DISTURBED DURING THE COURSE OF WORK SHALL BE REPAIRED TO MAINTAIN A 2-HOUR FIRE RATING. 7.0 TESTING AND BALANCING: THE CONTRACTOR SHALL BALANCE ALL AIR SYSTEMS AS INDICATED. SUBMIT RESULTS OF TESTING AND BALANCING ON STANDARD TAB CONTRACTOR'S FORMS TO THE ENGINEER FOR REVIEW. SYSTEMS SHALL BE BALANCED TO WITHIN +/- 10% OF DESIGN VALUES. FINAL BALANCING SHALL OCCUR AFTER ALL LEAKS IN THE BUILDING ENVELOPE HAVE BEEN IDENTIFIED AND SEALED. MECHANICAL SUBMITTAL SCHEDULE SECTION TITLE REQUIRED 220529 HANGERS AND SUPPORTS FOR PLUMBING PRODUCT DATA 220553 ID FOR PLUMBING PIPING PRODUCT DATA 220719 INSULATION FOR PLUMBING PIPING PRODUCT DATA 221000 PLUMBING PIPING PRODUCT DATA 230000 HEATING, VENTILATING & AIR-CONDITIONING - 230517 SLEEVES AND SLEEVE SEALS FOR HVAC PIPING PRODUCT DATA 230518 ESCUTCHEON FOR HVAC PIPING PRODUCT DATA 230519 METERS AND GAGES FOR HVAC EQUIPMENT PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M 230523 GENERAL DUTY VALVES FOR HVAC PIPING PRODUCT DATA 230529 HANGERS & SUPPORTS FOR HVAC PRODUCT DATA 230543 MECHANICAL VIBRATION AND MOVEMENT CONTROL PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M 230553 IDENTIFICATION FOR HVAC COMPONENTS PRODUCT DATA 230593 TESTING, ADJUSTING & BALANCING FOR HVAC QUALIFICATIONS, INSPECTION AND TEST REPORTS 230719 HVAC PIPING & EQUIPMENT INSULATION PRODUCT DATA 230900 INSTRUMENTATION & CONTROL FOR HVAC PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M 232113 HYDRONIC PIPING PRODUCT DATA 232123 HYDRONIC PUMPS PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M 233100 DUCTWORK PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M 233113 METAL DUCTS PRODUCT DATA 233300 AIR DUCT ACCESSORIES PRODUCT DATA 233700 AIR OUTLETS AND INLETS PRODUCT DATA 238210 FAN COIL COOLING UNITS PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M 238229 PANEL RADIATORS PRODUCT DATA, MANUFACTURERS INSTRUCTIONS, O&M 1 04/30/2021 ISSUE FOR 100% DD REVIEW 2 05/11/2021 ISSUE FOR DEMOLITION PERMIT 3 06/01/2021 ISSUE FOR COORDINATED REVIEW 4 06/04/2021 ISSUE FOR CONSTRUCTION M-101 3 4 1-1/2"HWS/R B53B00CFB49B BOOUD B00UL B49 B49A B00UL B51 B56 B00UM B00SD B52 B54 B55 B00UF 157 155 1 2 2 3 CRSTEAM CRSTEAM1 22 1 2 2 1 22 1 157 156 155 CRSTEAM CR STEAM 3 5 7 12 FCU-157 4 5 6 1-1/2" HWS/R 1" CHWS/R 656 C.O. 1" CD TG-2 8 EXISTING HEAT EXCHANGERCIRCULATING PUMP CP-1 B00UD 1-1/2" HWR 1-1/2" HWS NOTE: REFER TO SCHEMATIC FOR PIPING ARRANGEMENT, VALVES AND HYDRONIC TRIM IN THIS LOCATION. BYPASS VALVE (NO LONGER IN USE) 2" HWR DN TO HXR PUMP INLET 2" HWS 1-1/2" HWS 1-1/2" HYDRAULIC BRIDGE 1-1/2" HWR CORN E LL U N I V E RSI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 921 UNIVERSITY AVE ITHACA, NEW YORK 14850 SIBLEY HALL IT SOLUTIONS RENOVATIONS M-101 13291868 BASEMENT AND FIRST FLOOR MECHANICAL DEMOLITION & RENOVATION PLANS E. LEPORE JD 2004 JUNE 4, 2021 # 0' 4' 8'16' SCALE: 1/8"=1'-0" M-101 KEYED DEMOLITION NOTES 1 DISCONNECT RADIATOR BRANCH PIPING FROM EXISTING SYSTEM, CAP AND SEAL. 2 DEMO AND REMOVE EXISTING BRANCH PIPING TO RADIATOR UP THRU FLOOR. CAP AND SEAL. PATCH HOLE IN FLOOR WITH MATCHING MATERIALS. 3 DEMO AND REMOVE EXISTING 20x12 TRANSFER AIR DUCT. INFILL THE OPENING OF THE WOODEN FLOOR WITH MATCHING CONSTRUCTION. PAINT FLAT BLACK TO MATCH EXISTING FINISH. #M-101 KEYED RENOVATION NOTES 1 CONNECT NEW 1" CHWS/R PIPING TO EXISTING CHW PIPING AT FCU-157. CONNECT 1" CD TO EXISTING CD PIPING AT FCU-157. 2 RISE CHWS/R PIPING AND CONDENSATE DRAIN PIPING UP THRU FLOOR. REFER TO SECOND FLOOR PLAN FOR CONTINUATION. 3 INSTALL 20x12" TRANSFER AIR DUCT UP THRU FLOOR. PROVIDE 90 DEGREE ELBOW WITH 4' OF INTERNALLY LINED HORIZONTAL DUCT. PAINT INTERIOR AND EXTERIOR OF DUCT AND TRANSFER GRILLE FLAT BLACK TO MATCH THE EXISTING FINISH. 4 1-1/2" HWS/R DOWN THRU FLOOR TO BASEMENT LEVEL. PROVIDE MANUAL AIR VENTS AT THE TOP OF EACH RISER. 5 1" HWS UP THRU FLOOR TO SECOND FLOOR RADIATORS. 6 1" HWR DOWN THRU FLOOR FROM SECOND FLOOR RADIATORS. 7 1-1/2" HWS/R WITH ISOLATION VALVES, CAPPED AND SEALED FOR FUTURE. 8 CONNECT NEW 1-1/2” HWS/R PIPING TO EXISTING 2” HOT WATER SUPPLY AND RETURN DISTRIBUTION PIPING FROM THE HEAT EXCHANGER. SCALE:1/8" = 1'-0"1 PARTIAL BASEMENT MECH 0' 2' 4' 8' SCALE: 1/4"=1'-0" SCALE:1/4" = 1'-0"2 PARTIAL 1ST FLOOR MECH DEMOLITION SCALE:1/4" = 1'-0"4 PARTIAL 1ST FLOOR MECH SCALE:1/2" = 1'-0"3 ROOM B00UD MECH 0' 1' 2' 4' SCALE: 1/2"=1'-0" 1.1-1/2" HOT WATER SUPPLY AND RETURN PIPING SERVING THE PANEL RADIATORS ARE SIZED TO SUPPORT FUTURE HOT WATER PERIMETER RADIATION LOADS AT THE UPPER FLOOR. 2.CP-1 IS SIZED FOR THE CURRENT PANEL RADIATOR FLOW ON THIS PROJECT. FUTURE PROJECTS THAT CONNECT TO THE 1-1/2" HWS & R PIPING WILL NEED TO RE-EVALUATE THE PUMP PERFORMANCE. 3.ALL PIPE THRU FLOOR PENETRATIONS TO HAVE 2-HR FIRESTOP SYSTEM. GENERAL NOTES 1 04/30/2021 ISSUE FOR 100% DD REVIEW 2 05/11/2021 ISSUE FOR DEMOLITION PERMIT 3 06/01/2021 ISSUE FOR COORDINATED REVIEW 4 06/04/2021 ISSUE FOR CONSTRUCTION VD 24" DIA SA 3 2 1 2 20X6 261 262A 262B 260 260B 260A 261C 4 FD PR-261A PR-261B PR-261C 2 3 SG-4 100 CFM 12" ØSG-4 174 CFM 1" CHWS/R 5 T T SG-2 62 CFM 1 24" DIA SA VD20X6 VD T VD8" ØT 4 1" CD 24" Ø VD 7 7 FCU- 261D 14X10 SG-2 50 CFM 36x126 C.O.14X1014x10 RA DOWN ALONG WALL. TERMINATE 12" AFF 38X8 SG-1 400 CFM RG-1 400 CFM TG-1 50 CFM TG-1 50 CFM 9 T 8 10X10 TG-1 62 CFM 9 TG-1 62 CFM SG-3 30 CFM 6" Ø 9 TG-1 79 CFM TG-1 79 CFM 12" DIA. SG-2 79 CFM SG-2 65 CFM VD 10X10 9 TG-1 65 CFM TG-1 65 CFM 332 2 VD 8" Ø VD 8" Ø VD8" Ø 10X10 10X10 12" ØFD 10 10 CORN E LL U N I V E RSI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 921 UNIVERSITY AVE ITHACA, NEW YORK 14850 SIBLEY HALL IT SOLUTIONS RENOVATIONS M-102 13291868 SECOND FLOOR MECHANICAL DEMOLITION & RENOVATION PLANS E. LEPORE JD 2004 JUNE 4, 2021 SCALE: 3/16"=1'-0" 0' 2' 4' 6'12' SCALE:3/16" = 1'-0"1 2ND FLOOR DEMOLITION SCALE:3/16" = 1'-0"2 2ND FLOOR NEW WORK M-102 KEYED DEMOLITION NOTES 1 CAREFULLY REMOVE EXISTING 12x20" FLOOR TRANSFER GRILLE, FIRE DAMPER AND SLEEVE. HOLD ON SITE FOR REINSTALLATION. INFILL THE OPENING OF THE WOODEN FLOOR WITH MATCHING CONSTRUCTION. 2 DEMO AND REMOVE EXISTING STEAM RADIATOR AND ASSOCIATED STEAM PIPING, CONDENSATE PIPING, SUPPLY CONTROL VALVE AND CONDENSATE TRAP. PATCH FLOOR TO MATCH EXISTING CONSTRUCTION. 3 DEMO AND REMOVE EXISTING SUPPLY AIR DIFFUSER. PROVIDE TEMPORARY CAP AND SEAL DURING CONSTRUCTION. 4 DEMO AND REMOVE EXISTING STEAM SUPPLY AND CONDENSATE RETURN STUBS UP THRU FLOOR. PATCH FLOOR TO MATCH EXISTING CONSTRUCTION. M-102 KEYED RENOVATION NOTES 1 CAREFULLY REINSTALL EXISTING FLOOR TRANSFER GRILLE, FIRE DAMPER, AND SLEEVE. CONNECT TO LINED DUCT THRU FLOOR. 2 1" HWS UP THRU FLOOR TO PANEL RADIATOR. PROVIDE ISOLATION AND DIGITAL CONTROL VALVE. INSTALL PER DETAIL. REFER TO FIRST FLOOR PLAN FOR CONTINUATION. 3 1" HWR DN THRU FLOOR. PROVIDE BALANCE AND ISOLATION VALVE. INSTALL PER DETAIL. REFER TO FIRST FLOOR PLAN FOR CONTINUATION, 4 NEW FAN COIL UNIT FCU-261D LOCATED UP IN CEILING SPACE. PROVIDE CHW PIPING CONNECTIONS PER DETAIL. PROVIDE FLEXIBLE RETURN AIR DUCT CONNECTION. 5 1" CHWS/R PIPING UP THRU FLOOR. 1" CD DOWN THRU FLOOR. REFER TO FIRST FLOOR PLAN FOR CONTINUATION. 6 3/8" CONDENSATE PUMP DISCHARGE. RISE UP AND CONNECT TO 1" CD GRAVITY DRAIN. 7 1" CONDENSATE DRAIN WITHIN BEAM SPACE. MAINTAIN PITCH TO DRAIN 1/8" PER FOOT MINIMUM PITCH. 8 CONTROL PANEL MOUNTED HIGH ON WALL. REFER TO ELECTRICAL FOR 120V PWR FEED. 9 PROVIDE LINED TRANSFER DUCT WITH ONE 90 DEG FITTING AND AT LEAST 3 LINEAR FEET OF DUCT. 10 OFFSET 12" BRANCH DUCTS 45 DEG UP FROM 24" MAIN AND ROUTE BRANCH DUCTS AS CLOSE TO BOTTOM OF STRUCTURE AS POSSIBLE. # # 1 04/30/2021 ISSUE FOR 100% DD REVIEW 2 05/11/2021 ISSUE FOR DEMOLITION PERMIT 3 06/01/2021 ISSUE FOR COORDINATED REVIEW 4 06/04/2021 ISSUE FOR CONSTRUCTION F.L. PANEL RADIATOR PR-261A, PR-261B, PR-261C Tsa d OS AI BIAV SETPOINT TYPICAL FOR PANEL RADIATORS LOCATED IN ROOM 261A, 261B AND 261C BI BO AI AO AV BV SCH TREND NOTESSHOW ON GRAPHICSALARM DESCRIPTION X X X X+/-4° F FROM SETPOINT FAIL LAST SOFTWARE POINTS EMCSBACS X X X X XX X X X HARDWARE POINTS BASEBOARD RADIATIONS POINT NAME CONTROL VALVE POSITION COMMAND SPACE OCCUPANCY SPACE TEMPERATURE SETPOINT SPACE TEMPERATURE SEQUENCE OF OPERATIONS SYSTEM DESCRIPTION BASEBOARD PANEL RADIATORS (PR-261A, PR-261B, PR-261C) GENERAL SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). ALL SETPOINTS SHALL BE ADJUSTABLE. THE BACS SHALL BE CAPABLE OF STARTING AND STOPPING THE SYSTEM FOR SEVEN DIFFERENT DAILY SCHEDULES PER WEEK. THE BACS SHALL BE CAPABLE OF RETAINING ITS PROGRAMMING AND TIME SETTING DURING A LOSS OF POWER FOR AT LEAST TEN HOURS. DESIGN INTENT: FRESH AIR TO THE SPACE IS PROVIDED BY A PRE-EXISTING, CONSTANT VOLUME DEDICATED OUTSIDE AIR HANDLING SYSTEM (DOAS). IT IS INTENDED THAT THE FRESH AIR TO THE SPACE IS CONDITIONED AND THE PANEL RADIATORS ARE INTENDED TO OFFSET THE SPACE SENSIBLE LOADS TO PROVIDE SUFFICIENT HEATING TO THE SPACES DURING HEATING SEASON. SETPOINTS: SPACE HEATING TEMPERATURE SETPOINTS: OCCUPIED: 70 DEGF +/-1.5 DEGF OCCUPIED SETBACK: 70 DEGF +/-3 DEGF UNOCCUPIED: 70 DEGF +/-6 DEGF ZONE OCCUPANCY SCHEDULE: 6 AM TO 8 PM, MON -FRI SPACE OCCUPANCY ZONE OCCUPANCY SHALL BE DETERMINED BASED ON A COMBINATION OF A TIME OF DAY SCHEDULE AND A SPACE OCCUPANCY SENSOR. DURING THE SCHEDULED OCCUPANCY PERIOD, THE ZONE SHALL BE INITIALLY INDEXED TO OCCUPIED AND OPERATE FOR A MINIMUM OF 30 MINUTES, AT WHICH TIME THE SPACE OCCUPANCY SENSOR SHALL INDEX THE SPACE BETWEEN OCCUPIED AND OCCUPIED SETBACK MODE. IF THE SPACE BECOMES OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, AS DETERMINED VIA THE OCCUPANCY SENSOR, THE ZONE SHALL BE INDEXED TO OCCUPIED FOR THE DURATION OF OCCUPANCY. THE ZONE SHALL INDEX BACK TO UNOCCUPIED WHEN OCCUPANCY IS NOT SENSED FOR A PERIOD OF 30 MINUTES. ZONE TEMPERATURE CONTROL TEMPERATURE SETPOINTS SHALL BE DETERMINED BASED ON A COMBINATION OF PROGRAMMED SCHEDULE AND A SPACE OCCUPANCY SENSOR. AN OPTIMUM CONTROL ALGORITHM SHALL BE UTILIZED FOR THE SPACE. THE ALGORITHM SHALL, AS A MINIMUM BE A FUNCTION OF THE DIFFERENCE BETWEEN SPACE TEMPERATURE AND OCCUPIED SETPOINT, AND THE AMOUNT OF TIME PRIOR TO THE SCHEDULED OCCUPANCY. OCCUPIED HEATING: IF THE SPACE IS OCCUPIED DURING THE SCHEUDLE OCCUPIED PERIOD AND THE ZONE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING TEMPERATURE SETPOINT, THE PANEL RADIATOR CONTROL VALVE SHALL MODULATE TO MAINTAIN THE OCCUPIED HEATING TEMPERATURE SETPOINT. OCCUPIED SETBACK: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULE OCCUPIED PERIOD, THE ABOVE OCCUPIED HEATING SEQUENCES SHALL APPLY. THE SPACE SHALL BE MAINTAINED AT THE OCCUPIED HEATING SETBACK TEMPERATURE SETPOINT. UNOCCUPIED HEATING: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD AND THE ZONE TEMPERATURE FALLS BELOW THE UNOCCUPIED HEATING TEMPERATURE SETPOINT, THE PANEL RADIATOR CONTROL VALVE SHALL MODULATE TO MAINTAIN THE UNOCCUPIED HEATING TEMPERATURE SETPOINT. MS CS BI S SBO RADIATION HEAT CIRCULATION PUMP CP-1 BI BO AI AO AV BV SCH TREND NOTESSHOW ON GRAPHICSALARM DESCRIPTION X XMOTOR FAILURE VIA CURRENT SENSOR SOFTWARE POINTS EMCSBACS X X X X HARDWARE POINTS PUMP WITH MOTOR STARTER POINT NAME PUMP MOROT START/STOP PUMP MOROT STATUS X SEQUENCE OF OPERATIONS SYSTEM DESCRIPTION HOT WATER CIRCULATION PUMP (CP-1) GENERAL SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). ALL SETPOINTS SHALL BE ADJUSTABLE. THE BACS SHALL BE CAPABLE OF STARTING AND STOPPING THE SYSTEM FOR SEVEN DIFFERENT DAILY SCHEDULES PER WEEK. THE BACS SHALL BE CAPABLE OF RETAINING ITS PROGRAMMING AND TIME SETTING DURING A LOSS OF POWER FOR AT LEAST TEN HOURS. DESIGN INTENT: CIRCULATION PUMP CP-1 IS A SECONDARY PUMP TO THE SIBLEY EAST BASEMENT HEAT EXCHANGER, PERIMETER HEATING HOT WATER SYSTEM. THE DESIGN INTENT IS FOR THIS SECONDARY PUMPING SYSTEM TO PROVIDE HEATING HOT WATER TO NEW PERIMETER HEATING HOT WATER LOADS ON THE SECOND FLOOR WITH THE ABILITY TO EXPAND FLOW TO THE THIRD FLOOR EAST PERIMETER HEATING HOT WATER LOADS AS WELL. THIS SYSTEM WILL OPERATE ALONG WITH THE EXISTING PERIMETER BASEBOARD HOT WATER SYSTEM LOCATED IN MECHANICAL SPACE B00UD. SETPOINTS: THE HOT WATER SUPPLY SETPOINT TEMPERATURE IS CONTROLLED BY THE EXISTING HEAT EXCHANGER SYSTEM LOCATED IN MECHANICAL ROOM BOOUD. THE SYSTEM IS CURRENTLY PROGRAMMED FOR HOT WATER SUPPLY RESET TEMPERATURE BASED ON THE OUTSIDE AIR TEMPERATURE. THIS SYSTEM SHALL REMAIN AS PRESENTLY INSTALLED AND PROGRAMMED. CP-1 PUMP CONTROL: HOT WATER CIRCULATION PUMP CP-1 SHALL ENGAGE AND OPERATE WITH AN INTERNAL CONSTANT PRESSURE SETTING WHEN THE HEAT EXCHANGER AND ASSOCIATED PUMP LOCATED IN MECHANICAL SPACE BOOUD ARE ENABLED AND THERE IS A CALL FOR HEATING IN ANY OF THE ZONES SERVED BY THE PANEL RADIATORS (PR-261A, PR-261B AND PR-261C). WHEN THE ZONE TERMPERATURE OF ALL SERVED SPACES IS SATISFIED, CP-1 SHALL DISENGAGE UNTIL THERE IS ANOTHER CALL FOR HEATING. WHEN THE PERIMETER HEATING HOT WATER HEAT EXCHANGER SYSTEM IN B00UD IS DISENGAGED, CIRCULATION PUMP CP-1 SHALL ALSO REMAIN DISENGAGED. WHEN CP-1 IS INDEXED TO ENGAGE AND THERE IS NO POSITIVE INDICATION FROM THE CURRENT SENSOR FOR 5 MINUTES, AN ALARM SHALL BE GENERATED AT THE BACS USER WORKSTATION. M CORN E LL U N I V E RSI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 921 UNIVERSITY AVE ITHACA, NEW YORK 14850 SIBLEY HALL IT SOLUTIONS RENOVATIONS M-401 13291868 MECHANICAL CONTROLS E. LEPORE JD 2004 JUNE 4, 2021 NOT TO SCALE2PANEL RADIATOR CONTROL POINTS NOT TO SCALE1CIRCULATION PUMP CONTROL POINTS 1 04/30/2021 ISSUE FOR 100% DD REVIEW 2 05/11/2021 ISSUE FOR DEMOLITION PERMIT 3 06/01/2021 ISSUE FOR COORDINATED REVIEW 4 06/04/2021 ISSUE FOR CONSTRUCTION BI BO AI AO AV BV SCH TREND NOTESSHOW ON GRAPHIC ALARM DESCRIPTION X X FAILURE VIA CURRENT SENSOR SOFTWARE POINTS EMCSBACS HARDWARE POINTS COOLING ONLY FAN COIL UNIT POINT NAME Tsa d OS AI BIAV SETPOINT MS CS BI S SBO M d FAN COIL UNIT FCU-261D T AI COOLING COILCOOLING COIL CONTROL VALVE POSITION COMMAND FAN COIL UNIT FAN MOTOR START/STOP SPACE TEMPERATURE SETPOINT SPACE TEMPERATURE FCU STATUS DISCHARGE AIR TEMPERATURE NORMALLY CLOSED X X X X X X X X X X X X X SINGLE POINT SENSOR +/-4° F FROM SETPOINT X X X X SEQUENCE OF OPERATIONS SYSTEM DESCRIPTION 2-PIPE COOLING ONLY FAN COIL UNIT (FCU-261D) GENERAL SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). ALL SETPOINTS SHALL BE ADJUSTABLE. THE BACS SHALL BE CAPABLE OF STARTING AND STOPPING THE SYSTEM FOR SEVEN DIFFERENT DAILY SCHEDULES PER WEEK. THE BACS SHALL BE CAPABLE OF RETAINING ITS PROGRAMMING AND TIME SETTING DURING A LOSS OF POWER FOR AT LEAST TEN HOURS. DESIGN INTENT: IT IS INTENDED THAT THE FRESH AIR DELIVERED TO THE SPACE IS CONDITIONED UPSTREAM OF THIS SYSTEM AND DELIVERED AT A NEUTRAL TEMPERATURE. THE SUPPLEMENTAL COOLING COIL IS INTENDED TO OFFSET THE SPACE SENSIBLE LOADS (GENERATED BY COMPUTER SERVER EQUIPMENT). FAN COIL UNITS OF THIS TYPE ARE TYPICALLY PROVIDED WITH A THREE-SPEED MOTOR. FAN COIL SIZE IS TO BE SELECTED TO OFFET THE EXPECTED LOAD WHEN RUNNING AT LOW OR MEDIUM SPEED TO MINIMIZE NOISE. FAN SPEED IS TO BE SET AND OPERATE AT A CONSTANT SPEED. SETPOINTS: SPACE COOLING TEMPERATURE SETPOINTS: 70 DEGF +/-1.5 DEGF (NOTE THAT OCCUPANCY IS NOT PART OF THIS SEQUENCE OF OPERATION AS THIS SYSTEM IS MEANT TO MAINTAIN AN ENVIRONMENT, OCCUPIED OR UNOCCUPIED, FOR LIGHT DENSITY COMPUTER SERVER EQUIPMENT - 1-RACK AT APPROX 12 MBH) START/STOP THE SPACE SENSOR SHALL BE PROVIDED WITH A MANUAL OVERRIDE SWITCH TO ALLOW THE OCCUPANT TO HAVE THE CAPABILITY OF MANUALLY SELECTING FAN START/STOP. MANUAL CONTROL SHALL ALSO BE OVERRIDEN IF SPACE CONDITIONS RISE ABOVE THE HIGH LIMIT SPACE TEMPERATURE. FAN SPEED CONTROL THE FAN SHALL OPERATE AT CONSTANT SPEED WHENEVER THE SYSTEM IS INDEXED TO OPERATE. ZONE TEMPERATURE CONTROL TEMPERATURE SETPOINTS SHALL BE DETERMINED BASED ON A PROGRAMMED SCHEDULE. COOLING: IF THE ZONE TEMPERATURE RISES ABOVE THE COOLING TEMPERATURE SETPOINT, THE BACS SHALL INDEX THE UNIT TO AUTOMATIC MODE IF IT HAS BEEN PLACED IN MANUAL, THE UNIT FAN SHALL START, AND THE COOLING COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN SETPOINT. IF AT ANY TIME THE FAN COIL UNIT DISCHARGE AIR TEMPERATURE FALLS BELOW THE LOW LIMIT TEMPERATURE SETPOINT, THE BACS SHALL INDEX THE UNIT TO AUTOMATIC MODE IF IT HAS BEEN PLACED IN MANUAL MODE, THE UNIT FAN SHALL START, AND THE COOLING CONTROL VALVE SHALL OPEN. THE SYSTEM SHALL RUN FOR A PERIOD OF AT LEAST 30 MINUTES, AFTER WHICH THE SYSTEM SHALL REVER BACK TO NORMAL CONTROL. THE COOLING COIL CONTROL VALV SHALL BE CLOSED WHEN THE FAN COIL UNIT FAN IS OFF. N.C. AO CORN E LL U N I V E RSI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 921 UNIVERSITY AVE ITHACA, NEW YORK 14850 SIBLEY HALL IT SOLUTIONS RENOVATIONS M-402 13291868 MECHANICAL CONTROLS E. LEPORE JD 2004 JUNE 4, 2021 NOT TO SCALE1COOLING ONLY FAN COIL UNIT CONTROL POINTS 1 04/30/2021 ISSUE FOR 100% DD REVIEW 2 05/11/2021 ISSUE FOR DEMOLITION PERMIT 3 06/01/2021 ISSUE FOR COORDINATED REVIEW 4 06/04/2021 ISSUE FOR CONSTRUCTION SUPPLY RETURN V-1 (TYP) BALANCING VALVE PRESSURE/TEMPERATURE TEST PORT (TYP. OF 2) MANUAL AIR VENT COIL STRAINER BLOWDOWN WITH BRASS HOSE CONNECTION, CAP WITH CHAIN COIL DRAIN WITH BRASS HOSE CONNECTION, CAP AND CHAIN (TYP.) CONDENSATE DRAIN PAN WITH HIGH LEVEL FLOAT SWITCH, WIRED TO SHUT DOWN THE FAN UPON HIGH LEVEL CONDENSATE INTEGRAL CONDENSATE DRAIN PUMP PROVIDED WITH FAN COIL UNIT. CONTROL VALVE FLEXIBLE HOSE CONNECTION (TYP. OF 2) PUMPED CONDENSATE UP TO GRAVITY DRAIN. REFER TO PLANS T T P P P HWR HWS HEAT EXCHANGER PUMP CP-1 1-1/2" HWS 1-1/2" HWR BALANCING VALVE SET TO 6 GPM Y-STRAINER CHECK VALVE THERMOMETER PRESSURE GAUGE 1 1/2" HYDRAULIC BRIDGE (UNDERSLUNG CONNECTION) M HWS TRIM COVER WITH ACCESS PANEL PANEL RADIATOR HWR UNION MANUAL BALANCE VALVE CONTROL VALVE REFER TO SCHEDULE ISOLATION VALVE MFR SUPPLIED MANUAL AIR VENT CORN E LL U N I V E RSI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 921 UNIVERSITY AVE ITHACA, NEW YORK 14850 SIBLEY HALL IT SOLUTIONS RENOVATIONS M-501 13291868 MECHANICAL SCHEDULES AND DETAIL E. LEPORE JD 2004 JUNE 4, 2021 NOT TO SCALE1FAN COIL UNIT PIPING DETAIL NOT TO SCALE3CIRCULATION PUMP PIPING SCHEMATIC NOT TO SCALE2PANEL RADIATOR PIPING DETAIL 1 04/30/2021 ISSUE FOR 100% DD REVIEW 2 05/11/2021 ISSUE FOR DEMOLITION PERMIT 3 06/01/2021 ISSUE FOR COORDINATED REVIEW 4 06/04/2021 ISSUE FOR CONSTRUCTION 1. ACCEPTABLE MANUFACTURERS: BELIMO, VSI 2. ELECTRIC INPUT: 4-20mA OR 0-10VDC 3. 2-WAY VALVES: EQUAL PERCENTAGE FLOW CHARACTERISTIC 4. CONSTRUCTION: CHARACTERIZING DISK, FORGED BRASS, NICKEL PLATED BODY, STAINLESS STEEL BALL AND STEM, FIBERGLASS REINFORCED PTFE SEAT 5. RATINGS: 400 PSI PRESSURE, 0-212 F MEDIA TEMPERATURE RANGE 6. ALL CONTROL WIRING SHALL BE INSTALLED IN CONDUIT. 7. CONTROL WIRING SHALL BE UNSPLICED FROM THE CONTROLLER TO THE SENSOR OR DEVICE. 8. CONTROL WIRING SHALL NOT BE ROUTED IN THE SAME RACEWAY AS POWER WIRING. 9. CONTROL WIRING SHALL BE COLOR CODED AND LABELED AT ALL POINTS OF TERMINATION. 10. TEST EACH POINT THROUGH ITS FULL OPERATING RANGE TO VERIFY THAT SAFETY AND OPERATING CONTROL SET POINTS ARE AS REQUIRED. 11. TEST EACH CONTROL LOOP TO VERIFY STABLE MODE OF OPERATION AND COMPLIANCE WITH SEQUENCE OF OPERATION. ADJUST PID ACTIONS AS REQUIRED. 12. THE BACS CONTRACTOR SHALL ISSUE A REPORT UPON PROJECT COMPLETION STATING THAT THE SYSTEM IS COMPLETE, HAS BEEN ADJUSTED, AND HAS HAD ALL HARDWARE AND SOFWARE FUNCTIONS VERIFIED, THAT ALL ANALOG CONTROL LOOPS ARE TUNED, AND IS OPERATING IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. ANY DEVIATIONS FROM SPECIFIED SETTINGS OR OPERATIONS NECESSITATED DURING SYSTEM ADJUSTMENT SHALL BE SPECIFICALLY NOTED. CONTROL VALVE SCHEDULE TAG CV-261A CV-261B CV-261C CV-261D BELIMO MANUFACTURER BELIMO BELIMO BELIMO VALVE MODEL CCV -B211 CCV -B211 CCV -B211 CCV -B211 ACTUATOR MODEL TFX24-SR US TFX24-SR US TFX24-SR US TF24-SR US SERVICE PR-261A PR-261B PR-261C FCU-261D VALVE TYPE 2-WAY 2-WAY 2-WAY 2-WAY CONTROL ON/OFF ON/OFF ON/OFF MOD CAPACITY GPM 2.0 2.0 2.0 2.5 VALVE SIZE (IN) 1/2 1/2 1/2 1/2 CV 1.9 1.9 1.9 1.9 MAX PD (PSIG) 2.0 2.0 2.0 2.5 FAIL POS N.O. N.O. N.O. N.C. 1. ACCEPTABLE MANUFACTURERS: JCI, IEC, McQUAY, TRANE 2. RATINGS: ARI 440, ASHRAE 33, UL 1995 3. COIL: 5-ROW, COPPER TUBE, ALUMINUM FINS, TESTED TO 200 PSIG, 220 DEGREE ENTERING WATER TEMPERATURE, WITH MANUAL AIR VENT AND DRAIN VALVE. 4. FAN: DOUBLE WIDTH, DOUBLE INLET, FORWARD CURVED, CENTRIFUGAL 5. MOTOR: THREE-SPEED, ELECTRONICALLY COMMUTATED (EC), THERMAL OVERLOAD PROTECTION 6. DRAIN PAN: STAINLESS STEEL, COMPLYING WITH ASHRAE 62.1. PROVIDE WITH HIGH LEVEL FLOAT SWITCH HARD WIRED TO SHUT DOWN FAN UPON ACTUATION. 7. PROVIDE WITH INTEGRAL, SINGLE POINT POWER CONDENSATE DRAIN PUMP OPTION. 8. CABINET: BAKED ENAMEL FINISH, COLOR SELECTED BY ARCHITECT FROM STANDARD COLOR CHART , WITH 1/2-INCH COATED FIBERGLASS INSULATION 9. FILTERS: 1" THROW AWAY, MERV 3 10. ACCESSORIES: THREE-SPEED SWITCH, DISCONNECT SWITCH. 11. INSTALL FAN COIL UNITS TO COMPLY WITH NFPA 90A. FAN COIL UNIT SCHEDULE TAG FCU-261D 261D SERVES MANF BOD JCI MODEL BOD FHX-D-08 CABINET TYPE EXPOSED CFM 400 MOTOR ECM CAPACITY 12.4 EAT DB (F) 75 LAT DB (F) 52.9 COOLING COIL TOTAL (MBH) 9.7 SENSIBLE (MBH) EAT WB (F) 63 LAT WB (F) 52.3 AIR SIDE ESP (IN WG) 0.1 EWT (F) 47 LWT (F) 56.9 GPM 2.50 WPD (FT) 1.34 TYPE WATER WATER SIDE FLA 2.00 MCA 2.50 V/PH/HZ 115/1/60 NOTES SPECS SPECS SPECS 1. ALL DUCTWORK AND ACCESSORIES SHALL BE FABRICATED AND INSTALLED IN COMPLIANCE WITH THE LATEST ISSUE OF SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS -METAL AND FLEXIBLE. 2. CONSTRUCT TEES, BENDS, AND ELBOWS WITH RADIUS OF NOT LESS THAN 1.0 TIMES THE WIDTH OF DUCT ON CENTER LINES. 3. WHERE RECTANGULAR ELBOWS ARE USED, PROVIDE AIR FOIL TYPE TURNING VANES. 4. INCREASE DUCT SIZES GRADUALLY, AND IN COMPLIANCE WITH FIGURE 4-7 OF SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS -METAL AND FLEXIBLE. 5. BRANCH CONNECTIONS SHALL BE MADE WITH A 45 DEGREE ENTRY. STRAIGHT TEES ARE NOT ACCEPTABLE. 6. SEALANTS AND GASKETS: SURFACE BURNING CHARACTERISTICS SHALL BE A MAXIMUM FLAME-SPREAD INDEX OF 25, AND MAXIMUM SMOKE-DEVELOPED INDEX OF 50 WHEN TESTED TO UL 723. 7. ALL MANUAL BALANCING DAMPERS SHALL BE PROVIDED WITH LOCKING HAND QUADRANT. 8. CONNECT DIFFUSERS TO SUPPLY DUCTS WITH MAXIMUM OF 36-INCHES OF FLEXIBLE DUCT CLAMPED OR STRAPPED IN PLACE. 9. PROVIDE FLEXIBLE CONNECTORS TO CONNECT DUCTS TO EQUIPMENT. 10. INSTALL VOLUME DAMPERS AT POINTS ON SUPPLY, RETURN, AND EXHAUST SYSTEMS WHERE BRANCHES EXTEND FROM LARGER DUCTS. 11. USE BLO-R-VAC PVC HOSE (McMASTER-CARR PART NO 5666K46) MEETING UL 94VO FOR FLAME RETARDANCE TO CONNECT ADA FUME HOODS WITH ADJUSTABLE BASES TO THE EXHAUST SYSTEM. 12. PAINT ALL DUCTWORK EXPOSED TO VIEW IN OCCUPIED AREAS TO MATCH SURROUNDING FINISH. 13. REMOVE SURFACE CONTAMINANTS AND DEPOSITS FROM DUCTWORK AND EQUIPMENT PRIOR TO TESTING AND BALANCING. 14. ALL INSULATION AND ADHESIVE SHALL HAVE A MAXIMUM FLAME-SPREAD INDEX OF 25 AND A MAXIMUM SMOKE-DEVELOPED INDEX OF 50 WHEN TESTED IN ACCORDANCE WITH ASTM E84. TYPE A INSULATION: MINERAL FIBERGLASS BLANKET, ASTM C553 TYPE I, ASTM C1136 TYPE I FACTORY APPLIED FSK JACKET, K-VALUE BETWEEN 0.22 -0.29 BTU-IN/HR-FT²-˚F @ 75 ˚F, 0.75 PCF TYPE B INSULATION: MINERAL FIBERGLASS BOARD, ASTM C612 TYPE IA OR IB, ASTM C1136 TYPE I FACTORY APPLIED ASJ JACKET, K-VALUE BETWEEN 0.22 -0.29 BTU-IN/HR-FT²-˚F @ 75 ˚F, 3.0 PCF TYPE C INSULATION: BLACK FLEXIBLE CLOSED CELL FOAM ELASTOMERIC INTERNAL ACCOUSTIC DUCT LINER, ASTM C 534, ASTM C 1534, TYPE II, 1" THICK DUCT SERVICE LOCATION PRESSURE CLASS SEAL CLASS LEAKAGE CLASS RECT ROUND MATERIAL LINING INSULATON MIN R-VALUE MATERIAL FIELD JACKET VAPOR RETARDER FINISH DUCT SPECIFICATIONS SUPPLY: RECTANGULAR, EXPOSED, FCU -OUTLET SUPPLY, ROUND, EXPOSED, AHU -OUTLET RETURN, RECTANGULAR, EXPOSED, FCU -OUTLET TRANSFER: RECTANGULAR, EXPOSED 2" POS 2" POS 4" NEG 4" NEG A A A A 6 6 6 6 3 3 3 3 G90 GALVANIZED G90 GALVANIZED G90 GALVANIZED G90 GALVANIZED NONE NONE NONE NONE R-6 R-6 R-6 R-6 B A B C NONE YES EXPOSED STEEL PAINT AS NOTEDN/A NONE YES EXPOSED STEEL NONE EXPOSED STEEL NONE N/A HVAC PIPING SCHEDULE PIPE SERVICE HEATING HOT WATER HWS&R ABBREVIATION PIPE SIZE 1-1/2" & BELOW MATERIAL ASTM B88 TYPE L COPPER THICKNESS (IN) INSULATON CONDUCTIVITY (BTU-IN/HR-FT²-˚F) MEAN TEMP (°F)MATERIAL SPECS 1. SOLDER FILLER METALS: ASTM B32, LEAD-FREE ALLOYS. INCLUDE WATER FLUSHABLE FLUX ACCORDING TO ASTM B813. 2. DIELECTRIC FITTINGS: USE FLANGES OR COUPLINGS. UNIONS ARE UNACCEPTABLE 3. ALL INSULATION AND ADHESIVE SHALL HAVE A MAXIMUM FLAME-SPREAD INDEX OF 25 AND A MAXIMUM SMOKE-DEVELOPED INDEX OF 50 WHEN TESTED IN ACCORDANCE WITH ASTM E84. 4. TYPE A INSULATION: PRE-FORMED MINERAL FIBERGLASS, ASTM C547 TYPE I, ASTM C1136 FACTORY APPLIED SELF-SEALING ALL SERVICE JACKET. 5. INSTALL DRAINS, CONSISTING OF A TEE FITTING, NPS 3/4 BALL VALVE, AND SHORT NPS 3/4 THREADED NIPPLE AT LOW POINTS IN PIPING SYSTEM AS REQUIRED FOR DRAINAGE. 6. INSTALL MANUAL AIR VENT AT HIGH POINT IN PIPING SYSTEM AS REQUIRED FOR BLEEDING SYSTEM OF AIR. 7. INSTALL UNIONS IN PIPING, NPS 2 AND SMALLER, ADJACENT TO VALVES, AT FINAL CONNECTIONS OF EQUIPMENT, AND ELSEWHERE AS INDICATED 8. INSTALL STRAINERS ON INLET SIDE OF CONTROL VALVES, IN-LINE PUMP AND ELSEWHERE AS INDICATED. INSTALL NIPPLE AND BALL VALVE IN BLOWDOWN CONNECTION. 9. INSTALL PORTS FOR PRESSURE GAGES AND THERMOMETERS AT COIL INLET AND OUTLET CONNECTIONS. 10. PROVIDE PIPE LABLES AND DIRECTIONAL ARROWS ON ALL NEW PIPING SYSTEMS. LABELS SHALL BE PRINTED PLASTIC WITH CONTACT-TYPE, PERMANENT ADHESIVE BACKING. VAPOR RETARDER ASTM B88 TYPE M HARD TEMPER COPPER 1-1/2" & BELOW ASTM B88 TYPE L COPPER FITTINGS JOINT ASTM B32 SOLDER CHILLED WATER CONDENSATE DRAIN (COOLING) CHWS&R CD ALL SIZES ASTM B16.22 STD WROUGHT COPPER ASTM B16.22 STD WROUGHT COPPER ASTM B16.22 STD WROUGHT COPPER ASTM B32 SOLDER ASTM B32 SOLDER 1.5 1 1 0.25 -0.29 0.21 -0.27 0.21 -0.27 125 75 75 A A A NO YES YES UNIT NO.SERVES MANF. BOD MODEL BOD PANEL SIZE NECK SIZE WxH TYPE -CONFIGURATION MATERIAL MOUNTING FINISH NOTES REGISTER, GRILLE AND DIFFUSER SCHEDULE RG-1 TG-1 TG-2 SG-1 FCU-261D TRANSFER 157 TRANSFER FCU-261D KRUEGER KRUEGER KRUEGER KRUEGER 880 S80 S80 S80 14x20 12X12 22X14 40X10 12X18 10X10 20X12 38X8 RETURN -SINGLE DEFLECTION TRANS -SINGLE DEFLECTION TRANS -SINGLE DEFLECTION SUPPLY -DOUBLE DEFLECTION STEEL STEEL STEEL STEEL SURFACE STD WHITE STD WHITE SURFACE STD WHITE DUCT DUCT STD WHITE SG-2 SG-3 SG-4 SEE PLANS SEE PLANS SEE PLANS KRUEGER KRUEGER KRUEGER 880 880 880 14x8 8x8 14x8 12x6 6X6 12X6 SUPPLY -DOUBLE DEFLECTION SUPPLY -DOUBLE DEFLECTION SUPPLY -DOUBLE DEFLECTION STEEL STEEL STEEL SURFACE DUCT DUCT STD WHITE STD WHITE STD WHITE SPECS 1. ACCEPTABLE MANUFACTURERS: ANEMOSTAT, CARNES, KRUEGER, PRICE, TITUS 2. DOUBLE DEFLECTION -INDIVIDUALLY SPACED, ADJUSTABLE BLADES ON FRICTION PIVOTS, BLADES AND FRAME MADE OF 22 GAUGE STEEL. 3. SINGLE DEFLECTION -35 DEG DEFLECTION WITH BLADES INDIVIDUALLY SPACED, BLADES AND FRAME MADE OF 22 GAUGE STEEL. BLADES HELD BY MULLIONS AND WELDED TO THE FRAME. 4. PERFORMANCE -MFR SHALL PROVIDE PUBLISHED PERFORMANCE DATA TO INCLUDE 2 -7 OCTAVE BAND SOUND POWER LEVELS. 5. TESTED IN ACCORDANCE WITH ANSI / ASHRAE 70. 6. FINISH -ANODIC ACRYLIC PAINT, PAINTABLE. 1. ACCEPTABLE MANUFACTURERS: RUNTAL, ZEHNDER RITTLING, VULCAN 2. PERFORMANCE SHALL BE RATED ACCORDING TO HYDRONICS INSTITUTE'S I=B=R RATING STANDARD FOR BASEBOARD RADIATION 3. HEAT OUTPUT INDICATED IS THE OUTPUT AT STANDARD RATING CONDITIONS CORRECTED FOR WATER VELOCITY, ENTERING AIR TEMPERATURES, AND MOUNTING HEIGHTS, AS REQUIRED. 4. HEATING PANEL ELEMENTS: LOW CARBON STEEL FLATTENED TUBES WITH WELDED HEADERS. STEEL CORRUGATED FINS WELDED TO BOTH SIDES WITH 30 FINS PER FOOT MIN. MINIMUM WORKING PRESSURE OF 85 PSI AND 110 PSI TEST PRESSURE. 5. PANEL ARRANGEMENT: ACTIVE HOT WATER TUBES PLUS A FRONT SET OF INACTIVE TUBES FOR THERMAL PROTECTION. WELDED PERFORATED FLAT TOP GRILLE. 6. ELEMENT SUPPORTS: PROVIDE MANUFACTURER'S SUPPORT TO PERMIT LONGITUDINAL MOVEMENT ON ENCLOSURE BRACKETS WITHOUT ADDITIONAL BLOCKING OR STRAPPING.. 7. FINISH: GLOSS POWDER COAT IN MANUFACTURER'S STANDARD COLOR AS SELECTED BY ARCHITECT. 8. ACCESSORIES: PROVIDE WITH AIR VENTS. PROVIDE END TRIM ENCLOSURE, WITH ACCESS PANELS FOR ACCESS TO VALVES, PIPING TRIM AND COMPONENTS. END TRIM SIZED FOR FLUSH INSTALL TO ADJOINING WALLS. 9. INSTALL PANEL RADIATION IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. 10. CONTINUOUS WELDED SECTIONS. PANEL RADIATOR SCHEDULE TAG PR-261A PR-261B PR-261C LOCATION BOD MANF RUNTAL RUNTAL RUNTAL BOD CONFIGURATION FLAT PIPE STEEL FLAT PIPE STEEL FLAT PIPE STEEL BOD MODEL TT-4F TT-4F TT-4F NUMBER OF TIERS 4 4 4 NOM HEIGHT (IN) 12" 12" 12" HEAT OUTPUT (BTU/LF) 559 559 559 PIPE LENGTH (LF) 9 10 9 TOTAL OUTPUT (BTUH) 5031 5590 5031 WTD (°F) 10 10 10 FLOW RATE (GPM) 2 2 2 SPECS 261A 261B 261C ENT AIR TEMP (°F) 65 65 65 125 125 125 AVG WATER TEMP (°F)NOTES SPECS: 1. ECM VARIABLE SPEED CIRCULATOR WITH 3-CONSTANT PRESSURE CONTROL MODES AND LED DISPLAY. TERMINAL BOX POWER CONNECTION. 2. ACCEPTABLE MANUFACTURERS: ARMSTRONG, BELL & GOSSETT, GRUNDFOS 3. OPERATING RATINGS: 125 PSIG MAXIMUM OPERATING PRESSURE; 225 DEG F MAXIMUM CONTINUOUS OPERATING TEMPERATURE. 4. CASING: CAST IRON, WITH THREADED GAGE TAPPINGS AT INLET AND OUTLET, THREADED COMPANION-FLANGE CONNECTIONS. 5. IMPELLER: COMPOSITE CONSTRUCTION 6. SHAFT: ALLOY STEEL WITH ALUMINUM BRONZE SHAFT SEAL 7. MECHANICAL SEAL: INTERNALLY-FLUSHED WITH CERAMIC SEAL SEAT AND CARBON SEAL RING, BUNA-N BELLOWS AND GASKET. 8. BEARINGS: GREASE LUBRICATED BALL BEARINGS. 9. INSTALL PUMPS WITH ACCESS FOR PERIODIC MAINTENANCE INCLUDING REMOVAL OF MOTORS, IMPELLERS, COUPLINGS AND ACCESSORIES. 10. INDEPENDENTLY SUPPORT PUMPS AND PIPING SO WEIGHT OF PIPING IS NOT SUPPORTED BY PUMPS AND WEIGHT OF PUMPS IS NOT SUPPORTED BY PIPING. 11. PROVIDE CONTINUOUS THREAD HANGER RODS AND ELASTOMERIC HANGERS OF SUFFICIENT SIZE TO SUPPORT PUMP WEIGHT. 12. PROVIDE A CHECK VALVE AND SHUTOFF VALVE ON DISCHARGE SIDE OF PUMP. 13. PROVIDE A Y-TYPE STRAINER AND SHUTOFF VALVE ON SUCTION SIDE OF PUMP. 14. PROVIDE ONE PRESSURE GAUGE WITH VALVED CONNECTIONS TO THE UPSTREAM AND DOWNSTREAM PRESSURE TAPS. CIRCULATION PUMP SCHEDULE AND SPECS TAG CP-1 LOCATION SERVICE 2ND FLOOR RADIATION BOD MFG GRUNDFOS BOD MODEL ALPHA 1 26-99 SIZE 1-1/2" TYPE IN-LINE FLOW RATE GPM 6 HEAD 15 FLUID WATER MOTOR HP 0.16 POWER V / PH / HZ 115 / 1 / 60 NOTES: 1. SET PUMP TO CONSTANT PRESSURE SETTING. B00UD AMPS NOTES 11.7 WATTS 120 CORN E LL U N I V E RSI TYFOU N D E D 5681 AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 921 UNIVERSITY AVE ITHACA, NEW YORK 14850 SIBLEY HALL IT SOLUTIONS RENOVATIONS M-502 13291868 SCHEDULES E. LEPORE JD 2004 JUNE 4, 2021 1 04/30/2021 ISSUE FOR 100% DD REVIEW 2 05/11/2021 ISSUE FOR DEMOLITION PERMIT 3 06/01/2021 ISSUE FOR COORDINATED REVIEW 4 06/04/2021 ISSUE FOR CONSTRUCTION CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 921 UNIVERSITY AVE ITHACA, NEW YORK 14850 SIBLEY HALL - IT SOLUTIONS RENOVATION E-001 13291868 GENERAL NOTES, SCHEDULES AND SYMBOL LEGENDS M. SCHOLENO MPS 2004 June 4, 2021 ELECTRICAL SUBMITTAL SCHEDULE MATERIAL SCHEDULE/ SHOP DWGS. PRODUCT DATA SAMPLES INSPECTIONS & TESTS O&M DATA WARRANTIES LIGHTING X LIGHTING CONTROLS X FIRE ALARM DEVICES X WIRING DEVICES X CIRCUIT BREAKERS X MANUAL MOTOR STARTER X LUMINAIRE SCHEDULE TYPE DESCRIPTION MOUNTING SIZE MANUFACTURER CATALOG NO. VOLTAGE COLOR TEMP (CCT)LAMPS WATTAGE LUMENS FINISH A1 LINEAR LED INDIRECT/DIRECT PENDANT 2-1/2"WX2-1/2"HX48"L FINELITE HPX-P-ID-4'-V-V-835-TG-F-120-SC-FC-10%-FA100-FE-SW 120V 3500°K LED 44 5283 WHITE A2 LINEAR LED INDIRECT/DIRECT PENDANT 2-1/2"WX2-1/2"HX96"L FINELITE HPX-P-ID-8'-B-H-835-TG-F-120-SC-FC-10%-FA100-FE-SW 120V 3500°K LED 88 10566 WHITE A3 LINEAR LED INDIRECT/DIRECT PENDANT 2-1/2"WX2-1/2"HX96"L FINELITE HPX-P-ID-8'-V-V-835-TG-F-120-SC-FC-10%-FA100-FE-SW 120V 3500°K LED 137 16656 WHITE GENERAL ELECTRICAL NOTES 1.0 ELECTRICAL SCHEMATICS INDICATED ON CONTRACT DOCUMENTS ARE DIAGRAMMATIC. IT IS NOT THE INTENT TO SHOW EXACT OR MOST EFFICIENT ROUTING. VERIFY ALL DIMENSIONS AND FIELD CONDITIONS ON SITE. ANY CONFLICTS BETWEEN CONSTRUCTION DOCUMENTS AND FIELD CONDITIONS SHALL BE BROUGHT TO CORNELL'S PROJECT MANAGER FOR RESOLUTION BEFORE WORK PROCEEDS. 2.0 ASSURE PUBLIC AND WORKER SAFETY AT ALL TIMES. PROTECT ADJOINING AREAS FROM DAMAGE AND DUST. REMOVE ALL DEBRIS FROM SITE AND DISPOSE OF WASTE MATERIAL IN A SAFE MANNER. KEEP THE PREMISES FREE OF DEBRIS FROM THE EXECUTION OF WORK. DELIVER A FINAL PRODUCT THAT IS CLEAN AND OPERABLE. 3.0 FIRE STOP ELECTRICAL PENETRATIONS THROUGH FIRE RATED WALLS AND/OR FLOORS WITH MATERIAL EQUAL IN RATING TO THE CONSTRUCTION OF THE MATERIAL PENETRATED. 4.0 WORK SHALL BE COMPLETED AS SPECIFIED AND INDICATED ON CONTRACT DOCUMENTS. ANY SUGGESTED ALTERNATE MANUFACTURER OR METHOD OF INSTALLATION SHALL BE SUBMITTED TO PROJECT ENGINEER FOR APPROVAL PRIOR TO ORDERING ANY MATERIALS OR COMMENCING EXECUTION OF WORK. 5.0 GROUNDING SHALL BE IN STRICT ACCORDANCE WITH NEC ARTICLE 250. PROVIDE EQUIPMENT GROUND CONDUCTOR WITH EACH BRANCH CIRCUIT INDICATED ON CONTRACT DOCUMENTS. EQUIPMENT GROUND CONDUCTOR SHALL BE ROUTED WITH ASSOCIATED PHASE CONDUCTORS. 6.0 PROVIDE A NEW TYPED PANELBOARD DIRECTORY FOR EACH PANELBOARD. LABEL ALL NEW DEVICE FACEPLATES WITH SOURCE AND CIRCUIT NUMBER. PROVIDE PERMANENT LABEL ON SWITCHING DEVICES INDICATING EQUIPMENT SERVICE AND INVENTORY NUMBERS. COORDINATE EQUIPMENT INVENTORY NUMBERS WITH CORNELL UNIVERSITY'S MECHANICAL SHOP, 255-8667. 7.0 CIRCUITS RATED 20-AMP, 120 VOLT SHALL CONTAIN SEPARATE NEUTRAL CONDUCTORS. 8.0 CONDUCTORS SHALL BE A MINIMUM OF 12AWG, STRANDED COPPER, 600VAC, 90 DEGREE C, TYPE THHN/THWN-2 FOR DRY AREAS AND XHHW/THWN-2 FOR WET AREAS. 9.0 CONDUITS SHALL BE A MINIMUM OF 3/4 INCHES DIAMETER. CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT) AND SURFACE MOUNTED UNLESS NOTED OTHERWISE. 10.0 AIC RATING OF NEW CIRCUIT BREAKERS SHALL MATCH RATING OF RESPECTIVE PANELBOARD. SIZE AS INDICATED. 11.0 PROVIDE PULL STRING THROUGH NEW CONDUIT AND BOXES. PROVIDE SUPPORT HANGERS FOR CONDUIT AS NEEDED. 12.0 INSTALL RACEWAY SYSTEMS ENSURING PROPER ACCESS TO EQUIPMENT AND DEVICES AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE AND REPAIR. RACEWAYS THAT ARE NOT INSTALLED WITH THIS REQUIREMENT IN MIND SHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIES ARE CORRECTED. ELECTRICAL SCOPE OF WORK 1.0 REMOVAL OF ELECTRICAL POWER CIRCUITS AND OUTLETS AS REQUIRED FOR THE REMOVAL OF THE STOREFRONT AND WALL BETWEEN ROOMS 261A AND 261B. 2.0 REMOVE EXISTING LIGHT FIXTURES AND LIGHTING CONTROL. 3.0 INSTALL NEW CIRCUITS AND ELECTRICAL OUTLETS AS REQUIRED FOR THE NEW OFFICE LAYOUTS. 4.0 PROVIDE POWER AND RECEPTACLE LAYOUTS FOR NEW OFFICES, RACEWAY WILL BE UTILIZED IN THE WORKSPACE. 5.0 PROVIDE POWER FOR THE NEW SERVER RACK. 6.0 PROVIDE NEW LIGHTING LAYOUT WITH NEW 0-10V CONTROL. NEW LED LIGHTING WILL BE PROVIDED WITH SEPARATE LOCAL LIGHTING CONTROLS INCLUDING DIMMING, OCCUPANCY AND VACANCY CONTROLS AS REQUIRED FOR EACH NEW ROOM. 7.0 NO FIRE ALARM DETECTION IS REQUIRED AS THE SPACE IS FULLY SPRINKLERED. 8.0 MODIFY FIRE ALARM NOTIFICATION BASED ON NEW OFFICE LAYOUT. ELECTRICAL LEGEND LIGHTING LEGEND MOTOR 1'x4' LUMINAIRE HARDWIRED EQUIPMENT CONNECTION P-1A 12 HOMERUN TO PANEL P-1A, CIRCUIT #12. FED FROM 20A -1P BREAKER IS INTENDED UNLESS NOTED OTHERWISE. RUN GREEN WIRE GROUND FOR ALL CIRCUITS. PROVIDE ONE GROUND PER CIRCUIT. EMERGENCY POWER OFF (EPO) GROUND ROD ELECTRODE DUPLEX RECEPTACLE WITH GFCI PROTECTION DUPLEX RECEPTACLE WITH AFCI PROTECTION QUAD RECEPTACLE LINETYPES LEGEND SPECIAL RECEPTACLE5-30R PANELBOARD JUNCTION BOX B = INSTALLED IN BASEBOARD TR = INSTALLED IN WOOD TRIM/ CASEWORK/ WAINSCOTT SR = SURFACE RACEWAY WP = WEATHERPROOF AC = AIR CONDITIONER EM = EMERGENCY DUPLEX RECEPTACLE: DOUBLE DUPLEX RECEPTACLE MOTOR STARTER J 2'x4' LUMINAIRE CEILING MOUNTED LUMINAIRE EM LIGHTING BATTERY UNIT COMBO EXIT SIGN/EM LIGHTING BATTERY UNIT SINGLE FACE, WALL MOUNT EXIT SIGN DOUBLE FACE, WALL MOUNT EXIT SIGN SINGLE FACE, CEILING MOUNT EXIT SIGN DOUBLE FACE, CEILING MOUNT EXIT SIGN LIGHT SWITCH: SAFETY SWITCH (NON-FUSED) SAFETY SWITCH (FUSED) 3 = 3-WAY SWITCH 4 = 4-WAY SWITCH D = DIMMER SWITCH O = WALL SWITCH OCCUPANCY SENSOR V = WALL SWITCH VACANCY SENSOR W = WIRELESS SWITCH S = WIRELESS SCENE SWITCH WIRELESS OCCUPANCY SENSOR WIRELESS DAYLIGHT SENSOR 1'x2' LUMINAIRE FIRE ALARM LEGEND FIRE ALARM CONTROL PANEL BATTERY CABINET WATER FLOW SWITCH MUXPAD REMOTE ANNUNCIATOR D = DUCT SMOKE DETECTOR R = RELAY BASE BR = BEAM RECEIVER BT = BEAM TRANSMITTER SB = SOUNDER BASE SMOKE DETECTOR: TAMPER SWITCH AUDIBLE NOTIFICATION APPLIANCE FACP BATT MUX FAA NAC PANELNAC MANUAL PULL STATIONF S X F = FIXED TEMPERATURE R = RATE OF RISE R/F = COMBINATION RISE/FIXED TEMPERATURE HEAT DETECTOR: H X CARBON MONOXIDE DETECTORCO AM F XXcd C FS F S XXcd C TS ADDRESSABLE MODULE XXcd = CANDELA C = CEILING COMBO A/V NOTIFICATION APPLIANCE: XXcd = CANDELA C = CEILING VISUAL NOTIFICATION APPLIANCE: SUPPRESSION SYSTEM ELECTRICAL ABBREVIATIONS AC AIR CONDITIONER AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AFI ARC FAULT INTERRUPTER AMM ADDRESSABLE MONITOR MODULE AOM ADDRESSABLE OUTPUT MODULE ARB AUXILIARY RELAY BOARD ATS AUTOMATIC TRANSFER SWITCH B BASEBOARD BKR BREAKER C CONDUIT CD CANDELA CKT CIRCUIT CR CONTROL RELAY EC ELECTRICAL CONTRACTOR EMT ELECTRICAL METALLIC TUBING EPO EMERGENCY POWER OFF STATION FAA FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FSD FIRE SMOKE DAMPER GAA GENERATOR ALARM ANNUNCIATOR GFI GROUND FAULT INTERRUPTER GND GROUND HP HORSEPOWER KW KILOWATT LC LIGHTING CONTACTOR LFMC LIQUID TIGHT FLEXIBLE METALLIC CONDUIT LTG LIGHTING MCB MAIN CIRCUIT BREAKER MLO MAIN LUG ONLY MTS MANUAL TRANSFER SWITCH NAC NOTIFICATION APPLIANCE CIRCUIT NIC NOT IN CONTRACT OE OVERHEAD ELECTRIC PC PHOTOCELL PM PLUGMOLD PNL PANEL PP POWER PANEL PVC POLYVINYL CHLORIDE CONDUIT RE REUSE EXISTING RGS RIGID GALVANIZED STEEL CONDUIT SR SURFACE RACEWAY ST SHUNT TRIP TM THERMAL MAGNETIC TR TRIM/CASEWORK/WAINSCOTT TSP TWISTED SHIELDED PAIR TYP TYPICAL UE UNDERGROUND ELECTRIC UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY V VOLTS VA VOLT AMPS WP WATERPROOF UNDERGROUND ELECTRICUE UNDERGROUND LIGHTINGUL OVERHEAD ELECTRICOE TO BE PROVIDED DEMOLITION / TO BE RELOCATED EXISTING TO REMAIN UNDERGROUND TELCOUC MOUNTING HEIGHTS CARD READER 48" TOP OF BOX LIGHT SWITCH 48" TOP OF BOX RECEPTACLE 18" TOP OF BOX DATA OUTLET 18" TOP OF BOX TV OUTLET 84" TOP OF BOX PHONE OUTLET 48" TOP OF BOX SAFETY SWITCH 60" CENTERLINE OF HANDLE MOTOR STARTER 60" CENTERLINE OF HANDLE PANELBOARD 72" TOP OF PANELBOARD MANUAL PULL STATION 48" OPERABLE HANDLE NOTIFICATION APPLIANCE 80" BOTTOM OF LENS DOOR HOLD OPEN COORDINATE IN FIELD EM BATTERY UNIT 96" BOTTOM OF UNIT EM REMOTE UNIT 102" BOTTOM OF UNIT EXIT SIGN 96" BOTTOM OF UNIT LIGHT POLE WITH LED LUMINAIRES, REFER TO PLANS FOR NUMBER AND CONFIGURATION OF HEADS GENERAL ELECTRICAL DEMOLITION NOTES 1.0 ELECTRICAL EQUIPMENT SHOWN DASHED ON DEMOLITION DRAWINGS, INCLUDING ASSOCIATED ANCHORS, SUPPORTS, STRAPS, BOXES, FITTINGS, AND OTHER APPURTENANCES NOT SHOWN, SHALL BE DISCONNECTED AND REMOVED. REMOVE ASSOCIATED BRANCH CIRCUITRY TO SOURCE, UNLESS NOTED OTHERWISE. 2.0 EXISTING RACEWAYS AND DEVICE BACKBOXES NOT INTERFERRING WITH NEW WORK SHALL BE REUSED WHERE POSSIBLE. 3.0 PROVIDE JUNCTION BOXES, RACEWAYS, AND WIRING TO MODIFY/EXTEND EXISTING SYSTEMS AND CIRCUITS FED DOWNSTREAM OF ELECTRICAL EQUIPMENT SHOWN TO BE DEMOLISHED. 4.0 CUT DEMOLISHED CONDUITS INSTALLED THRU WALLS AND FLOORS FLUSH WITH THE SURFACE AND PATCH PENETRATIONS (FIRESTOP IF LOCATED ON A FIRE RATED SURFACE). PATCH AND PAINT SURFACES IN EXPOSED AREAS TO MATCH SURROUNDING MATERIALS, FINISHES, AND COLORS. 5.0 PROVIDE BLANK COVERPLATES ON UNUSED BACKBOXES REMAINING FROM DEMOLITION NOT SPECIFIED TO BE INFILLED. 6.0 EXISTING EQUIPMENT SHOWN TO REMAIN SHALL BE PROTECTED DURING CONSTRUCTION. MAGNETIC DOOR HOLDERDH CARD READERCR IT/ COMMUNICATIONS LEGEND DATA RECEPTACLE X = NUMBER OF CABLES TO BE PROVIDED WIRELESS ACCESS POINT OUTLET-CEILING MTD. WIRELESS ACCESS POINT OUTLET-WALL MTD.WAP x EM EMERGENCY LIGHT FIXTURE WIRELESS VACANCY SENSOR OS VS DS 0' 4' 8'16' SCALE: 1/8"=1'-0" EQUIPMENT CONNECTION SCHEDULE - NOT AUTOMATED LABEL DESCRIPTION ROOM NO. PANEL RATING (kW, W, VA, A, HP, FLA)VOLTAGE PHASE WIRE & CONDUIT STARTER DISCONNECT NOTES ADDITIONAL REQUIREMENTSTYPE LOC BY ENC AUX BY RATING LOC ENC CP-1 CIRCULATION PUMP B00UD PANEL C 120 W 115 1 2#12 & 1#12 AWG GND CU IN 3/4" EMT MANUAL AU EC 1, 3 FCU-261D FAN COIL UNIT 261D PANEL 2A 2 FLA 115 1 2#12 & 1#12 AWG GND CU IN 3/4" EMT MANUAL AU EC 1, 3 NOTES: 1. MAKE CONNECTION TO EQUIPMENT.A. START-STOP IN COVER. 2. INSTALL MOTOR STARTER FURNISHED BY OTHERS.B. HAND-OFF-AUTO IN COVER. 3. MAKE CONNECTIONS TO CONTROLS.C. PILOT LIGHT IN COVER. 4. FIELD CONTROL WIRING BY OTHERS.D. AUXILIARY CONTACTS. 5. RUN FEED THRU CONTACTOR. CONTROL FROM FAN SHUTDOWN RELAY. E. CONTROL CIRCUIT TRANSFORMER. 6. PROVIDE DUCT SMOKE DETECTOR.F. TWO-SPEED MOTOR CONTROLLER. 7. PROVIDE GFI RECEPTACLE AT UNIT. CIRCUIT TO NEAREST 120V CIRCUIT. G. KEY OPERATED - UP/DOWN OR OPEN/CLOSE. 8. WIRE THRU T-STAT THEN TO MOTOR. 1 04/30/2021 ISSUE FOR 100% DD REVIEW 2 05/11/2021 ISSUE FOR DEMOLITION PERMIT 3 06/01/2021 ISSUE FOR COORDINATED REVIEW 4 06/04/2021 ISSUE FOR CONSTRUCTION FEM SSS FB WAP 2 PNL 2A 13 13 1 1717 11 11 46/48 1 1 1 2 4 5 3 6 7 8 9 2 2 4 AM 6 9 9 6 8 6 8 TYPICAL 1 1 TYPICAL 2 68 1 2 RE RE RERE RE 8 19/21/23 25/27 3 6 6 6 6 RE 6 8 10 11 CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 921 UNIVERSITY AVE ITHACA, NEW YORK 14850 SIBLEY HALL - IT SOLUTIONS RENOVATION E-101 13291868 PARTIAL 2ND FLOOR ELECTRICAL DEMOLITION PLANS M. SCHOLENO MPS 2004 June 4, 2021 # 0' 2' 4' 8' SCALE: 1/4"=1'-0" E-101 KEYED DEMOLITION NOTES 1 DISCONNECT AND REMOVE EXISTING LIGHT FIXTURES. REMOVE EXISTING CONDUIT AND CIRCUIT BACK TO POINT BEYOND DEMOLITION AND TAG FOR REUSE. PROPERLY STORE EXISTING FIXTURES FOR REUSE AS INDICATED WITH LABEL "RE". 2 DISCONNECT AND REMOVE EXISTING LIGHT SWITCH. REMOVE EXISTING CONDUIT AND CIRCUITRY BACK TO SOURCE. 3 DISCONNECT AND REMOVE EXISTING EXIT SIGN. MAINTAIN CIRCUIT CONTINUITY FOR OTHER DEVICES ON SAME CIRCUIT. 4 DISCONNECT EXISTING FURNITURE FEED POWER AND COMMUNICATIONS. REMOVE BACK TO SOURCE OR NEAEREST JUNCTION BOX. MAINTAIN CIRCUIT CONTINUITY TO ANY OTHER DEVICES ON SAME CIRCUIT. 5 DISCONNECT AND REMOVE EXISTING CEILING MOUNTED RECEPTACLES. REMOVE CONDUIT AND CIRCUITRY BACK TO SOURCE. 6 DISCONNECT AND REMOVE POWER RECEPTACLES. REMOVE EXISTING CONDUIT AND CIRCUITRY BACK TO SOURCE OR NEAREST JUNCTION BOX. MAINTAIN CIRCUIT CONTINUITY FOR OTHER DEVICES ON SAME CIRCUIT. 7 DISCONNECT AND REMOVE DELAYED EGRESS DOOR HARDWARE POWER SUPPLY AND FIRE ALARM CONNECTION. REMOVE EXISTING CONDUIT AND CIRCUITRY BACK TO SOURCE OR NEAREST JUNCTION BOX. MAINTAIN CIRCUIT CONTINUITY FOR OTHER DEVICES ON SAME CIRCUIT. 8 DISCONNECT AND REMOVE EXISTING DATA OUTLETS. REMOVE EXISTING CONDUIT AND CABLING BACK TO SOURCE. 9 DISCONNECT AND REMOVE EXISTING SPEAKER. REMOVE CONDUIT AND CABLING BACK TO SOURCE. 10 DISCONNECT AND REMOVE ELECTRICAL AND COMMUNICATION DEVICES IN EXISTING FLOORBOX. REMOVE ALL CABLING AND CONDUIT BACK TO SOURCE. REMOVE FLOOR BOX AND PROPERLY INFILL AND PATCH FLOOR TO MATCH EXISTING. 11 DISCONNECT AND REMOVE EXISTING FIRE ALARM NOTIFICATION DEVICE. PROPERLY STORE FOR REUSE. TAG EXISTING FIRE ALARM CIRCUIT FOR REUSE. SCALE:1/4" = 1'-0"1 PARTIAL 2ND FLOOR ELECTRICAL DEMOLITION PLAN 1 04/30/2021 ISSUE FOR 100% DD REVIEW 2 05/11/2021 ISSUE FOR DEMOLITION PERMIT 3 06/01/2021 ISSUE FOR COORDINATED REVIEW 4 06/04/2021 ISSUE FOR CONSTRUCTION CP-1 2 B49B B00UD B43 B41A B41 TELECOMMUNICATIONS ROOM B49 B00CD B49A B00CF B53 B55B54B52 B00UF B00CD B51 B00SD B46 B00UC B00UL PANEL 2 PANEL 1 PANEL C PANEL C -13 1 CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 921 UNIVERSITY AVE ITHACA, NEW YORK 14850 SIBLEY HALL - IT SOLUTIONS RENOVATION E-102 13291868 BASEMENT ELECTRICAL RENOVATION PLAN M. SCHOLENO MPS 2004 June 4, 2021 SCALE:1/4" = 1'-0"1 PARTIAL BASEMENT - ELECTRICAL PLAN E-102 KEYED RENOVATION NOTES 1 PROVIDE 20A, 120V SINGLE POLE CIRCUIT BREAKER IN EXISTING 1 POLE SPACE (13) FOR CIRCULATION PUMP. MATCH EXISTING PANEL TYPE AND AIC RATING. 2 PROVIDE MANUAL MOTOR STARTER WITH OVERLOAD PROTECTION SIMILAR TO SQ. D TYPE 2510FG1. SIZE OVERLOADS BASED ON MOTOR NAMEPLATE DATA AND CIRCUIT WITH 2#12 AWG & 1#12 AWG GND CONDUCTORS IN ¾:” EMT CONDUIT. COORDINATE WITH EQUIPMENT PROVIDED. 0' 2' 4' 8' SCALE: 1/4"=1'-0" # 1 04/30/2021 ISSUE FOR 100% DD REVIEW 2 05/11/2021 ISSUE FOR DEMOLITION PERMIT 3 06/01/2021 ISSUE FOR COORDINATED REVIEW 4 06/04/2021 ISSUE FOR CONSTRUCTION EM VS VS OS OS PP PP PP PP VS VS PP VS PP VS PP PP PP OS PP PNL 2A 261A 261B 261C 262C 262B262A 250 1 3 9 7 9 D D D D D D D A2 A2 A2 A2 A2 A3 RE RE RE A3 a a a a a a b c c 5 33 3 4 3 4 A3 A3 RE RE RE RE RERE RE RE A1 2 b b bbbb b b 6 6 6 6 6 111 1 1 1 RE 2 2 2 2 2 1 5 999 9 810 10 8 a a a a 6 cb b NLNLNLNL A1 1A11 5 10 8 261 CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 921 UNIVERSITY AVE ITHACA, NEW YORK 14850 SIBLEY HALL - IT SOLUTIONS RENOVATION E-103 13291868 PARTIAL 2ND FLOOR LIGHTING RENOVATION PLAN M. SCHOLENO MPS 2004 June 4, 2021 SCALE:1/4" = 1'-0"1 PARTIAL 2ND FLOOR LIGHTING RENOVATION PLAN E-103 KEYED RENOVATION NOTES 1 PROVIDE NEW PENDANT MOUNTED LED LIGHT FIXTURES AS INDICATED. REFER TO LIGHT FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION. MOUNT BOTTOM OF FIXTURE 8’-6” AFF. MODIFY/EXTEND EXISTING LIGHTING CIRCUIT SAVED DURING DEMOLITION AND CONNECT. CIRCUIT NEW LIGHT FIXTURES WITH 2#12 AWG & 1#12 AWG GROUND IN 3/4" EMT CONDUIT. TYPICAL. 2 REUSE EXISTING LIGHT FIXTURES PREVIOUSLY SAVED DURING DEMOLITION. MOUNT BOTTOM OF FIXTURE 10’-6” AFF/ORIGINAL PENDANT LENGTH. MODIFY/EXTEND EXISTING LIGHTING CIRCUIT SAVED DURING DEMOLITION AND CONNECT. CIRCUIT WITH 2#12 AWG & 1#12 AWG GROUND IN 3/4" EMT CONDUIT. 3 PROVIDE 0-10V WIRELESS WALL-BOX DIMMER SWITCH LOAD CONTROLLER. PROVIDE 120V POWER FROM LIGHTING CIRCUIT AND CONNECT 0-10V TO LIGHT FIXTURES. INSTALL PER MANUFACTURES RECOMMENDATIONS. 4 PROVIDE WIRELESS DIMMER KEYPAD WITH SINGLE ROCKER SWITCH FOR ON/OFF CONTROL WITH THE ABILITY TO ADJUST THE DIMMING LEVEL UP OR DOWN BY PRESSING AND HOLDING THE SWITCH. PROVIDE 120V POWER FROM LIGHTING CIRCUIT AND CONNECT 0-10V TO LIGHT FIXTURES. INSTALL PER MANUFACTURES RECOMMENDATIONS. 5 PROVIDE 20A, 120V SPECIFICATION GRADE LIGHT SWITCH AND CIRCUIT TO ASSOCIATED LIGHTING FOR CONTROL. 6 PROVIDE A WIRELESS JUNCTION BOX MOUNTED SENSOR INTEGRATION MODULE FOR LIGHTING CIRCUIT CONTROL. MODULE SHALL COMMUNICATE VIA WIRELESS RF SIGNAL TO ASSOCIATED WALL MOUNTED CONTROLLER. CIRCUIT PER MANUFACTURERS RECOMMENDATIONS. PROVIDE 120V POWER FROM LIGHTING CIRCUIT. 7 PROVIDE A WIRELESS JUNCTION BOX MOUNTED LIGHTING LOAD CONTROLLER FOR LIGHTING CIRCUIT CONTROL. CONTROLLER SHALL COMMUNICATE VIA WIRELESS RF SIGNAL TO ASSOCIATED WALL MOUNTED CONTROLLER. CIRCUIT PER MANUFACTURERS RECOMMENDATIONS. 8 PROVIDE OCCUPANCY SENSOR POWER PACK AND CIRCUIT THOUGH EXISTING LIGHTING CIRCUIT FOR CONTROL. CIRCUIT PER MANUFACTURERS RECOMMENDATIONS. 9 PROVIDE PIR PRESENCE DETECTOR . MOUNT PER MANUFACTURERS RECOMMENDATIONS AND WIRE TO VACANCY TERMINAL ON SENSOR INTEGRATION MODULE FOR CONTROL. CIRCUIT PER MANUFACTURERS RECOMMENDATIONS. 10 PROVIDE PIR PRESENCE DETECTOR. MOUNT PER MANUFACTURERS RECOMMENDATIONS AND WIRE TO ASSOCIATED POWER PACK FOR CONTROL. CIRCUIT PER MANUFACTURERS RECOMMENDATIONS. # LIGHTING SYSTEM DESIGN BASIS 1.0 PROVIDE LIGHTING CONTROL SYSTEM WITH COMPONENTS SIMILAR TO THE FOLLOWING: 1.1 ROOMS 261A, 261B, 261C & 261E 1.11 (1) 0-10V WALLBOX DIMMER SWITCH/CONTROLLER- ZUMMESH-5A-LV-W-S 1.12 (1) WIRELESS JUNCTION BOX-MOUNTED SENSOR INTEGRATION MODULE- ZUMMESH-JBOX-SIM 1.13 (1) PIR PRESENCE DETECTOR- CRESTRON – GLA-IR-QUATTRO-HD-COM1-24 1.2 ROOM 261D & 261F 1.21 (1) SPECIFICATION GRADE 120V, 20A LIGHT SWITCH - LUTRON/LEVITON/HUBBELL 1.22 (1) POWER PACK- STEINEL - TR 200 1.23 (1) PIR PRESENCE DETECTOR- CRESTRON – GLA-IR-QUATTRO-HD-COM1-24 1.3 ROOM 261 1.31 (2) WIRELESS KEYPAD, ROCKER DIMMER SWITCH- ZUMMESH-KP10A-W-S 1.32 (1) 0-10V WALLBOX DIMMER SWITCH/CONTROLLER- ZUMMESH-5A-LV-W-S 1.33 (2) WIRELESS JUNCTION BOX-MOUNTED SENSOR INTEGRATION MODULE- ZUMMESH-JBOX-SIM 1.34 (2) PIR PRESENCE DETECTOR- CRESTRON – GLA-IR-QUATTRO-HD-COM1-24 1.35 (1) WIRELESS J-BOX LOAD CONTROLLER - ZŪM - J-BOX LOAD CONTROLLER 2.0 PROVIDE ALL REQUIRED EQUIPMENT, CONDUIT, BOXES, WIRING, CONNECTORS, HARDWARE, SUPPORTS, ACCESSORIES, PROGRAMMING, ETC. AS NECESSARY FOR A COMPLETE OPERATING SYSTEM THAT PROVIDES THE CONTROL INTENT INDICATED 0' 2' 4' 8' SCALE: 1/4"=1'-0" 1 04/30/2021 ISSUE FOR 100% DD REVIEW 2 05/11/2021 ISSUE FOR DEMOLITION PERMIT 3 06/01/2021 ISSUE FOR COORDINATED REVIEW 4 06/04/2021 ISSUE FOR CONSTRUCTION F J F F WAPPNL 2A 261A 261B 261C 262C262B262A 250 15cd PM 1 11 4 5 6 7 8 PNL 2A -48 1 12 PNL 2A -46 2 2 2 22 FCU-261D 9 PNL 2A -50 22 2 2 2 PNL 2A -17 PNL 2A -23 5 10 3 6 PNL 2A -52 8 8 8 8 88 2 812 PNL 2A -25 PNL 2A-54 PNL 2A -13 PNL 2A -11 PM 13 14 PNL 2A -19 PNL 2A -21 15 16 8 SR SR SR 7 2 PNL 2A -27 12 COORDINATE WITH FURNITURE LOCATION COORDINATE WITH FURNITURE LOCATION PNL 2A -5261 CORN E LL U N I V E R SI TYFOU N D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 921 UNIVERSITY AVE ITHACA, NEW YORK 14850 SIBLEY HALL - IT SOLUTIONS RENOVATION E-104 13291868 PARTIAL 2ND FLOOR ELECTRICAL RENOVATION PLAN M. SCHOLENO MPS 2004 June 4, 2021 SCALE:1/4" = 1'-0"1 PARTIAL 2ND FLOOR - ELECTRICAL RENOVATION PLAN E-104 KEYED RENOVATION NOTES 1 PROVIDE NEW 120V, 20A SPECIFICATION GRADE DUPLEX RECEPTACLES AND CIRCUIT AS INDICATED WITH 2#12 AWG & 1#12 AWG GND CONDUCTORS IN ¾:” EMT CONDUIT. 2 PROVIDE NEW 120V, 20A SPECIFICATION GRADE DUPLEX RECEPTACLES AND CIRCUIT TO EXISTING RECEPTACLE CIRCUIT WITH 2#12 AWG & 1#12 AWG GND CONDUCTORS IN ¾:” EMT CONDUIT. 3 PROVIDE 20A, 120V DEDICATED CIRCUIT FOR HVAC CONTROL PANEL. COORDINATE CONNECTION WITH PANEL LOCATION. CIRCUIT WITH 2#12 AWG & 1#12 AWG GND CONDUCTORS IN ¾” EMT CONDUIT. 4 RELOCATE EXISTING FIRE ALARM NOTIFICATION DEVICE SAVED DURING DEMOLITION AND MOUNT SUCH THAT THE ENTIRE LENS IS NOT LESS THEN 80" AFF OR GREATER THAN 96" AFF. MODIFY/EXTEND EXISTING FIRE ALARM NOTIFICATION CIRCUIT SERVING ROOM TO NEW LOCATION AND RECONNECT. 5 PROVIDE NEW STEEL PLUGMOLD SIMILAR TO WIREMOLD PLUGMOLD 2000 SERIES WITH OUTLETS 18” ON CENTER. CIRCUIT WITH 2#12 AWG & 1#12 AWG GND CONDUCTORS IN ¾:” EMT CONDUIT. 6 PROVIDE 20A, 120V DUPLEX RECEPTACLES FOR SERVER EQUIPMENT AND PROVIDE 20A, 120V DEDICATED CIRCUIT. CIRCUIT WITH 2#12 AWG & 1#12 AWG GND CONDUCTORS IN ¾” EMT CONDUIT. 7 PROVIDE FIRE ALARM NOTIFICATION DEVICE MOUNTED SUCH THAT THE ENTIRE LENS IS NOT LESS THEN 80" AFF OR GREATER THAN 96" AFF. CIRCUIT FROM NEAREST FIRE ALARM NOTIFICATION CIRCUIT SERVING ROOM AREA AND MATCH EXISTING SYSTEM CABLING AND FIRE ALARM DEVICES. DESIGN BASIS GAMEWELL FCI L SERIES SELECTABLE HORN STROBE. 8 PROVIDE QUANTITY OF DATA JACKS AS INDICATED BY NUMBER ADJACENT TO SYMBOL. PROVIDE PULL STRING FOR FUTURE CABLING BY CIT FROM EXISTING TELECOMMUNICATIONS ROOM IN BASEMENT. CIT SHALL PULL CABLE, TERMINATE AND TEST. TYPICAL. COORDINATE ALL ROUTING, LOCATIONS AND QUANTITY OF JACKS WITH CIT PRIOR CONSTRUCTION. 9 PROVIDE MANUAL MOTOR STARTER SIMILAR TO SQ. D TYPE 2510KG1 FOR FCU AND CIRCUIT WITH 2#12 AWG & 1#12 AWG GND CONDUCTORS IN ¾:” EMT CONDUIT. COORDINATE WITH EQUIPMENT PROVIDED. 10 PROVIDE NEW STEEL DUAL CHANNEL SURFACE MOUNTED RACEWAY SIMILAR TO WIREMOLD 4000 SERIES WITH OUTLETS AS INDICATED. CIRCUIT WITH 2#12 AWG & 1#12 AWG GND CONDUCTORS IN ¾:” EMT CONDUIT. COORDINATE DATA JACKS AND CABLING WITH CIT. 11 PROVIDE NEW 120V, 20A SPECIFICATION GRADE DUPLEX RECEPTACLES IN DUAL CHANNEL SURFACE RACEWAY AND CIRCUIT AS INDICATED WITH 2#12 AWG & 1#12 AWG GND CONDUCTORS IN ¾:” EMT CONDUIT. 12 PROVIDE 20A, 120V POWER CONNECTION FOR FURNITURE. CIRCUIT WITH 2#12 AWG & 1#12 AWG GND CONDUCTORS IN ¾” EMT CONDUIT. COORDINATE LOCATION WITH FURNITURE LOCATION AND CONNECT PER MANUFACTURER RECOMMENDATIONS. 13 REPLACE EXISTING SPARE 3 POLE CIRCUIT BREAKER (CIRCUITS 19,21 & 23) WITH 3 – 20A, 120V 1 POLE CIRCUIT BREAKERS TO SUPPORT NEW CIRCUITING FOR RENOVATION. MATCH EXISTING PANEL TYPE AND AIC RATINGS. 14 REPLACE EXISTING SPARE 2 POLE CIRCUIT BREAKER (CIRCUITS 25 & 27) WITH 2 – 20A, 120V 1 POLE CIRCUIT BREAKERS TO SUPPORT NEW CIRCUITING FOR RENOVATION. MATCH EXISTING PANEL TYPE AND AIC RATINGS. 15 REPLACE EXISTING SPARE 3 POLE CIRCUIT BREAKER (CIRCUITS 50,52 & 54) WITH 3 – 20A, 120V 1 POLE CIRCUIT BREAKERS TO SUPPORT NEW CIRCUITING FOR RENOVATION. MATCH EXISTING PANEL TYPE AND AIC RATINGS. 16 REPLACE EXISTING SPARE 2 POLE CIRCUIT BREAKER (CIRCUITS 46 & 48) WITH 2 – 20A, 120V 1 POLE CIRCUIT BREAKERS TO SUPPORT NEW CIRCUITING FOR RENOVATION. MATCH EXISTING PANEL TYPE AND AIC RATINGS. # 0' 2' 4' 8' SCALE: 1/4"=1'-0" TELECOMMUNICATIONS GENERAL NOTES 1.0 NEW COMMUNICATION OUTLETS: 1.1 PROVIDE 8 POSITION, 8 WIRE, T568A CODED CATEGORY 6 MODULAR JACKS. PANDUIT CJ688TG. 1.2 OUTLETS (FACEPLATES AND ADAPTERS) FOR THE JACK MODULES WILL BE FROM THE SAME MANUFACTURER. PANDUIT IVORY BEZEL CBEE SERIES. 2.0 OBTAIN OUTLET NUMBER CONFIGURATION FOR ROOM LAYOUTS FROM THE CIT/INFRASTRUCTURE ENGINEER. TYPICALLY THE OUTLET DESIGNATIONS ARE ASSIGNED USING THE ROOM NUMBER FOLLOWED BY THE LETTERS A-Z IN A CLOCKWISE ORIENTATION FROM THE LEFT OF THE PRIMARY ENTRANCE OF THE ROOM. 3.0 REFER TO CORNELL COMMUNICATIONS DESIGN AND CONSTRUCTION STANDARD FOR MORE INFORMATION. 4.0 ALL CABLING, TERMINATING AND TESTING SHALL BE PROVIDED BY CIT. FIRE ALARM GENERAL NOTES 1.0 COMPLY WITH THE AUTHORITY HAVING JURISDICTION (AHJ), NFPA 72, THE NATIONAL ELECTRICAL CODE, THE AMERICANS WITH DISABILITIES ACT (ADA) AND ALL STATE, LOCAL AND MUNICIPAL ORDINANCES. 2.0 REFER TO FIRE ALARM PLANS FOR QUANTITIES AND LOCATIONS OF FIRE ALARM EQUIPMENT. 3.0 IDENTIFY FIRE ALARM WIRING BY SYSTEM AND FUNCTION AT BOTH ENDS AND WITHIN CABINETS AND JUNCTION BOXES WITH PREMARKED, SELF-ADHESIVE, WRAPAROUND TYPE LABELS. WIRE DESIGNATIONS SHALL CORRESPOND WITH POINT-TO-POINT WIRING DIAGRAMS. 4.0 FIRE ALARM EQUIPMENT SHALL BE UL LISTED COMPATIBLE WITH THE EXISTING FIRE ALARM SYSTEM. 5.0 SYNCHRONIZE ALL VISUAL NOTIFICATION APPLIANCES. 6.0 PROVIDE ALL EQUIPMENT, ACCESSORIES AND PROGRAMMING REQUIRED TO MODIFY THE EXISTING FIRE ALARM SYSTEM. 7.0 FIRE ALARM CABLING SHALL BE INSTALLED IN MINIMUM 3/4" EMT CONDUIT. REUSE EXSITNG CONDUIT WHERE POSSIBLE. FIRE ALARM TESTING NOTES 1.0. TEST ALL FIRE ALARM WIRING FOR CONTINUITY AND VERIFY THAT ALL FIRE ALARM 2.0 UPON COMPLETION OF FIRE ALARM WORK IN THE BUILDING, PERFORM A REACCEPTANCE TEST PER NFPA 72 WITH CORNELL EH&S REPRESENTATIVE. VERIFY CORRECT RECEIPT OF ALARM, SUPERVISORY, AND TROUBLE SIGNALS (INPUTS); OPERATION OF EVACUATION SIGNALS AND AUXILIARY FUNCTIONS (OUTPUTS); CIRCUIT SUPERVISION, INCLUDING DETECTION OF OPEN CIRCUITS AND GROUND FAULTS; AND POWER SUPPLY SUPERVISION FOR DETECTION OF LOSS OF AC POWER AND DISCONNECTION OF SECONDARY BATTERIES. 3.0 FIRE ALARM SYSTEM SHALL BE COMPLETELY OPERABLE AT ALL TIMES DURING CONSTRUCTION. IN THE EVENT A ZONE MUST BE DEACTIVATED, COORDINATE SHUTDOWN IN ADVANCE WITH THE OWNER AND AHJ AND PROVIDE FIRE WATCH IN ALL PUBLIC SPACES OF THE AFFECTED ZONE(S) AT ALL TIMES THE BUILDING IS OCCUPIED. 4.0 FIRE ALARM SYSTEM SHALL BE FULLY OPERATIONAL AT THE END OF EACH DAY. 5.0 THROUGH WALL PENETRATIONS FOR REMOVED CONDUITS AND/OR THE INSTALLATION OF PROPOSED CONDUITS SHALL BE FIRE STOPPED TO MAINTAIN THE FIRE RATING OF WALL ASSEMBLY. 1 04/30/2021 ISSUE FOR 100% DD REVIEW 2 05/11/2021 ISSUE FOR DEMOLITION PERMIT 3 06/01/2021 ISSUE FOR COORDINATED REVIEW 4 06/04/2021 ISSUE FOR CONSTRUCTION