Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Code Review
CPET = 63'1 BR UNIT B 101 2 BR UNIT 102 2 BR UNIT 103 1 BR UNIT B 104 74 SF ELEC 150STAIR 02 ST02 127 SF LAUNDRY 147 75 SF JANITORS 146 75 SF WATER 145 127 SF RPZ 144 STAIR 01 ST0173 SF BLDG STOR 141 UPUP E E E E 1 BR ADA 201 1 BR UNIT A 202 2 BR TNHS 203 STAIR 01 ST01 1 BR UNIT A 205 1 BR UNIT A 204 STAIR 02 ST02 E E UP DNUPDN HVI 1 BR UNIT C 301 1 BR UNIT C 302 2 BR TNHS 203 STAIR 01 ST01 1 BR UNIT C 305 1 BR UNIT C 304 STAIR 02 ST02 CODE COMPLIANCE PLAN LEGEND COMMON PATH OF EGRESS TRAVEL EGRESS ACCESS TRAVEL DISTANCE E EXIT FEC FIRE EXTINGUISHER CABINET. PROVIDE FIRE RATED CABINET WHEN INSTALLED IN FIRE RATED PARTITION CPOE = X'-X" EATD = X'-X" LOAD CAPACITY SYMBOL OCCUPANT CAPACITY OCCUPANT LOAD 1 HR FIRE PARTITION 1 HR FIRE BARRIER 2 HR FIRE BARRIER CODE COMPLIANCE PLAN GENERAL NOTES CODE COMPLIANCE DRAWINGS ARE INTENDED TO ASSIST IN THE PERMIT PROCESS AND TO PROVIDE GENERAL INFORMATION TO THE CONTRACTORS WITH RESPECT TO LIFE-SAFETY PROVISIONS OF THE PROJECT. THESE DRAWINGS SHOULD NOT BE USED TO DETERMINE THE SCOPE OF OTHER WORK SPECIFICALLY INDICATED ELSEWHERE IN THE DOCUMENTS. THESE DRAWINGS SHALL BE USED FOR THE LOCATIONS OF FIRE-RESISTANT RATED WALL CONSTRUCTION. INTERIOR LOAD-BEARING PARTITIONS (NOT INDICATED ON CODE COMPLIANCE PLAN) SHALL BE BUILT WITH MATERIALS AND CONSTRUCTION IDENTICAL TO THOSE ASSEMBLIES WITH A 1-HR FIRE RESISTIVE RATING (I.E., BOARD TYPE AND FASTENER SPACING). OPENING PROTECTION (FIRE DOORS AND FIRE DAMPERS) AND THROUGH PENETRATION FIRE STOP SYSTEMS ARE NOT REQUIRED UNLESS SPECIFICALLY INDICATED OTHERWISE. WOOD-FRAMED FIRE-RESISTANT RATED FLOOR/CEILING AND ROOF/CEILING ASSEMBLIES. BCNYS SECTION 714.4.2, EXCEPTION #7 ALLOWS THE GYPSUM BOARD CEILING MEMBRANE PROTECTION TO BE INTERRUPTED BY THE WALL CONSTRUCTION. THE WALL CONSTRUCTION MUST HAVE A DOUBLE TOP PLATE AND BE SHEATHED ON BOTH SIDES WITH 5/8" TYPE X GYPSUM BOARD. ALL PENETRATING ITEMS THROUGH THE DOUBLE TOP PLATE SHALL BE PROTECTED BY AN APPROVED 1-HOUR RATED THROUGH-PENETRATION FIRESTOP SYSTEM. THE FOLLOWING BUILDING AND ACCESSIBILITY CODES AND STANDARDS ARE APPLICABLE TO THIS PROJECT: A.2015 INTERNATIONAL BUILDING CODE* B.2015 INTERNATIONAL EXISTING BUILDING CODE* C.2015 INTERNATIONAL FIRE CODE* D.2015 INTERNATIONAL PLUMBING CODE* E.2015 INTERNATIONAL MECHANICAL CODE* F.2015 INTERNATIONAL FUEL GAS CODE* G.2017 NEW YORK STATE UNIFORM CODE SUPPLEMENT H.NATIONAL ELECTRICAL CODE, NFPA 70, - 2014 EDITION AS REFERENCED BY THE NYS CODES ABOVE. I.ICC/ANSI A117.1, ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES - 2009 EDITION AS REFERENCED BY THE NYS CODES ABOVE. J.U.S. DEPARTMENT OF JUSTICE, 2010 AMERICANS WITH DISABILITIES ACT (ADA) STANDARDS FOR ACCESSIBLE DESIGN. K.2015 INTERNATIONAL ENERGY CONSERVATION CODE** *AS AMENDED BY 2017 NYS UNIFORM CODE SUPPLEMENT **AS AMENDED BY 2016 NYS ENERGY CODE SUPPLEMENT INDICATES 'ADA' UNITS. ADA UNITS ARE TYPE 'A' ACCESSIBLE UNITS ALL OTHER UNITS ARE TYPE 'B' ACCESSIBLE UNITS. BATHROOMS AT TYPE 'B' ACCESSIBLE UNITS TO FOLLOW TYPE 'A' ACCESSIBLE GUIDELINES UL L546: 1-HR RATED FLOOR/CEILING ASSEMBLY: TYPICAL FLOOR CEILING ASSEMBLY UL P531: 1-HR RATED ROOF/CEILING ASSEMBLY TYPICAL ROOF CEILING ASSEMBLY UL U306: 1-HR RATED WALL TYPICAL DEMISING WALL UL U311: 1 HR RATED WALL TYPICAL RATED WALL UL X650: 1 HR RATED STEEL COLUMN TYPICAL RATED STEEL COLUMN UL N614: 1 HR RATED STEEL BEAM TYPICAL RATED STEEL BEAM TYPICAL FIRE RATED ASSEMBLY TEST REFERENCES: X X X"CLEAR WIDTH 1. 2. 3. 4. 2 HR FIRE WALL SPECIFIC CODE INFORMATION NOTE KB KEY LOCK BOX These documents and all the ideas, arrangements, designs and plans indicated thereon or presented thereby are owned by and remain the property of SWBR and no part thereof shall be utilized by any person, firm, or corporation for any purpose whatsoever except with the specific written permission of SWBR. All rights reserved. © 387 East Main Street Rochester NY 14604 585 232 8300 | rochester@swbr.com FILE PATH:SWBR Project Number Checked By: Project Manager: Drawn By: Revisions HCR SHARS NO.: 201860499/13/2019 1:58:17 PMC:\1-Local Revit Models 2019\15225_Elm Street Apartments_Central_erikr.rvt15225.00 ESR Code Compliance Plans EJG ESR G-101 Construction Set Ithaca Neighborhood Housing Services Cayuga Flats 115 West Clinton Street Ithaca NY, 14850 9/13/2019 209 Elm Street, Ithaca NY 1/8" = 1'-0"1 LOWER LEVEL CODE COMPLIANCE PLAN 1/8" = 1'-0"2 FIRST FLOOR CODE COMPLIANCE PLAN 1/8" = 1'-0"3 SECOND FLOOR CODE COMPLIANCE PLAN BUILDING DATA & CODE SUMMARY - 2016 NEW YORK STATE UNIFORM CODE WITH REFERENCE TO: INTERNATIONAL BUILDING CODE 2015 AND 2016 UNIFORM CODE SUPPLEMENT SINGLE MIXED OCCUPANCY SEPARATED NON-SEPARATED IF SEPARATED, FIRE RESISTANCE RATING OF FIRE BARRIER (Table 508.4): OCCUPANCY CLASSIFICATION(S): USE(S): CONSTRUCTION CLASSIFICATION : (Chapter 6) AUTOMATIC SPRINKLER SYSTEM PROVIDED:YES 13R NO 13D13NFPA STANDARD: HEIGHT & AREA - ALLOWABLE: AREA PER TABLE 504.3 (HEIGHT IN FEET), 504.4 (HEIGHT IN STORIES) & 506.2 (AREA) sf OCCUPANCY CLASSIFICATION TABULAR AREA TABULAR HEIGHT FEET sf sf STORIES ft ft ft AREA INCREASE - FRONTAGE (506.3) YES NO FRONTAGE F = PERIMETER P = WIDTH OF OPEN SPACE W = FRONTAGE INCREASE lf = ft lf lf NOTES: "NS" = BUILDINGS "NOT" EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM. "S1" = BUILDINGS A MAXIMUM OF ONE STORY ABOVE GRADE PLANE EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 (NFPA 13 SPRINKLER SYSTEM). "SM" = BUILDINGS TWO OR MORE STORIES ABOVE GRADE PLANE EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 (NFPA 13 SPRINKLER SYSTEM). "S13R" = BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.2 (NFPA 13R SPRINKLER SYSTEM). OCCUPANCY CLASSIFICATION:SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY Covered mall and open mall buildings [402] High-rise buildings [403] – Occupied floors > 75 feet Atriums [404] Underground buildings [405] Motor vehicle related occupancies [406] Group I-2 (health care) [407] Group I-3 (correctional or detention) [408] Motion picture projection rooms [409] Stages, platforms, technical production areas [410] Special amusement buildings [411] Aircraft related occupancies [412] Combustible storage [413] Hazardous materials [414] Group H1 through H5 [415] Application of flammable finishes [416] Drying rooms [417] Organic coatings [418] FIRE PROTECTION SYSTEMS: Indicate size and location of fire areas on code compliance drawing (Chapter 9) FIRE PROTECTION SYSTEM REQUIRED PROVIDED SECTION AUTOMATIC SPRINKLER ALTERNATIVE AUTO FIRE EXT STANDPIPE PORTABLE FIRE EXTINGUISHER FIRE ALARM & DETECTION EMERGENCY ALARM SMOKE CONTROL SYSTEM SMOKE & HEAT REMOVAL (903) (904) (905) (906) (907) (908) (909) (910) MEANS OF EGRESS: DESIGN OCCUPANT LOAD SUMMARY - TABLE 1004.1.2 (Chapter 10) FLOOR LEVEL DESIGN OCCUPANT FIRST SECOND LOWER LEVEL TOTAL LOAD MEANS OF EGRESS ELEMENT REQUIRED PROVIDED SECTION NUMBER OF EXITS EXIT ACCESS TRAVEL DISTANCE DEAD-END LIMIT COMMON PATH OF TRAVEL LIMIT (Table 1006.3.1) (Table 1017.2) (1020.4) (1006.2.1) PROJECT NAME: BUILDING DATA & CODE REVIEW PREPARED BY: DATE: SWBR PROJECT NUMBER: CHECKED BY: DATE: HR (Chapter 4) (Chapter 5) FIRE COMMAND CENTER (911) (Chapter 3) COMBINATION OF BOTH Live/Work units [419] SF FOOTNOTE FOOTNOTENS/S1/SM/S13RCLASS ALLOWABLE BUILDING AREA - MULTI-STORY: SINGLE OCCUPANCY - FRONTAGE INCREASE EQUATION 5-2 ALLOWABLE AREA Aa = At + (NS x lf)OCCUPANCY GROUP SF ALLOWABLE AREA PER STORY (Sa = 1)SF Group I-1, R-1, R-2, R-3, R-4 [420] Hydrogen fuel gas rooms [421] Ambulatory care facilities [422] Storm shelters [423] Children's play structures [424] Hyperbaric facilities [425] Combustible dusts, grain processing & storage [426] FIRE DEPARTMENT CONNECTIONS FIRE PUMPS EMERGENCY RESPONDER SAFETY CARBON MONOXIDE DETECTION (912) (913) (914) (915) sf ft LEVEL OCCUPANCY CLASSIFICATION FEET ALLOWABLE HEIGHT SUMMARY STORIES ALLOWABLE HEIGHT FEETSTORIES ACTUAL HEIGHT COMPLIANT YES NO (30 FEET MAX.) (NOT TO EXCEED .75) HEIGHT & AREA - ACTUAL: BUILDING HEIGHT HEIGHT IN FEET HEIGHT IN STORIES ft BUILDING AREA SUMMARY FIRST BUILDING AREA sf SECOND LOWER LEVEL TOTAL (NOT INCLUDING BASEMENT) sf sf sf (Chapter 5) ELM STREET APARTMENTS 15225.00 ESR 6/25/2019 APARTMENTS VB X X X X X X X X X X 21 21 65 1 200' 20' 75' 1 63' N/A 63' R-2 7,000 60 3 23 R-2 X X X X S13R S13RS13R R-2 0" 7,000 X X X R-2 (4,465)N/A 4 60 34 X 3 35'3 4,465 4,150 12,765 4,150