HomeMy WebLinkAbout283110-001 Fire AlarmPAGE:1 of 1 DATE:1/14/2020 ATTN: PHONE: FAX: QTY 1 1 1 1 2 2 2 1 2 9 2 11 2 7 2 2 27 16 27 1 3 SUBMITTAL SHIP TO:TO: MODEL PROJECT Schuler-Haas Electric Corp 240 Commerce Drive Rochester, NY 14623 HVI Strobes Fire alarm system Cayuga FlatsJoe DiFransisco 607- West Fire Systems, Inc. is the factory authorized service organization for the above system(s). HPF902ULAD MS-7AF P2RL SRL P2RH-LF HW-LF 21010408 21010407-A HVIPANEL CHWL 12 Volt, 7 A Hr. sealed lead acid batteryPS1270 ASD-PL3 ATD-L3 B300-6 E3BB-FLUSH SLP-BLK SLC-PM FIRECELL PREPARED BY: Chuck Schramm The attached CAD drawings were created specifically for the new system(s) as outlined above. The attached line loss and battery calculations are based on the future strobes in apts being installed now to make sure that the power supplies can accommodate them if needed. PS12120 LCD-SLP DACT-E3 Kidde Hardwire i12010SCO Smoke/CO detector with 10 Year, White Fire alarm system equipment Smart Loop Panel addressable FACP, Black enclosure with 7A power supply, LCD-SLP display. Requires SLP add-on SLC module, System Sensor. 1 loop-318 devices. Required for SLP panel order Digital alarm communication transmitter Fire alarm cellular communicator LCD Touch screen display unit A Size, Flush Remote LCD enclosure, black, incl keylock, LCD slot (LCD-E3, LCD-SLP) 12 Volt, 12 A Hr. sealed lead acid battery 9 amp 24 volt UL listed fire alarm NAC expander Copy of NYS Alarm License is attached Battery and Line Loss Calculations are attachd 53 PIXLEY INDUSTRIAL PKWY • ROCHESTER, NY 14624 • TEL (585) 663-8530 • FAX (585) 663-8633 DESCRIPTION Special Notes; Kidde Hardwire i12010S interconnect Ionixation Sensor Smoke Alarm with 10 Year HVI Strobe WFS HVI Custom panel. Includes cabinet, PS and timer modules Chime only; 12/24 volt; white NOTE: Analog photoelectronic sensor, Velociti only, bright white color Thermal sensor 135°, Velociti only, bright white color 6" base, flanged, low profile, use with analog sensor or Velociti sensors, bright white color Addressable double action station Horn/strobe, 12/24 volt, multi-candela 15, 30, 75, 95, 110, 135, 185, red Strobe, 12/24 volt, multi-candela 15, 30, 75, 95, 110, 135, 185, red 520 Hz Low Frequency Sounder/Strobe; 12/24 volt, high candella 135 150, 177, 185cd, red 520Hz Low Frequency Sounder; 12/24 volt, white Project: Contractor:Standby Hours:24 Prepared By:Alarm Mins:5 DATE:Derating Factor:1.2 Total Available Nac Power:6 Voltage Drop Warning Threshold %:10 Total Standby Current (Amps):0.147 3.047 Total Alarm Current (Amps) Standby Time In Hours:24 0.208 Alarm Minutes / 24 (1.2 Mins) Total Standby AH Required:3.516 0.635 Total Alarm AH Required Total Combined AH Required: Multiply By The Derating Factor: Minimum Battery AmpHours Required: Battery Amp Size Provided: TOTAL NAC CURRENT: Device Qty Draw Standby Qty Draw Alarm Panel Information S3 FACP Control panel 1 x 0.11100 0.11100 1 x 0.24300 0.24300 Panel Add On Modules DACT-E3 Digital communicator 1 x 0.01800 0.01800 1 x 0.01800 0.01800 SLC-PM SLC Addressable loop card 1 x 0.01400 0.01400 1 x 0.01400 0.01400 0 x 0.00000 0 x 0.00000 TOTAL PANEL CURRENT 0.14300 0.27500 Remote Annunciator(s) LCD-SLP Remote Annunciator 1 x 0.03000 0.03000 1 x 0.06500 0.06500 0.065 0 x 0.00000 0 x 0.00000 REMOTE ANNUNCIATOR CURRENT 0.030 0.065 OHMs Per 1000FT Length of Wire Volts @ EOL % Drop LINE LOSS CALCULATIONS 18 AWG Solid 7.77 200 23.90 0.42% Addressable Loop 1 Devices ASD-PL2F Addresable Smoke Detector 10 x 0.00025 0.00250 10 x 0.00000 0.00000 ATDF Series Heat Detector 2 x 0.00020 0.00040 2 x 0.00030 0.00060 MS-7A Addressable pull station 2 x 0.00030 0.00060 2 x 0.00030 0.00060 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.004 0 x 0.00000 0 x 0.00000 TOTAL SLC 1 CURRENT 0.004 0.001 OHMs Per 1000FT Length of Wire Volts @ EOL % Drop LINE LOSS CALCULATIONS 18 AWG Solid 7.77 1500 23.96 0.17% Addressable Loop 2 Devices 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.000 0 x 0.00000 0 x 0.00000 TOTAL SLC 2 CURRENT 0.000 0.000 OHMs Per 1000FT Length of Wire Volts @ EOL % Drop LINE LOSS CALCULATIONS 0 24.00 0.00% 0.04 Wire Type and AWG Rating Voltage Drop 0.00 Alarm Current Wire Type and AWG Rating Voltage Drop 0.10 Wire Type and AWG Rating Voltage Drop Standby Current 4.15 1.20 4.98 12.00 2.77 1/14/2020 System Current Draw - S3 Addressable Control Panel w/ Dialer Cayuga Flats Schuler Haas C Schramm NAC Circuit 1 System Sensor P2RL 15cd 2 x 0.00000 0.00000 2 x 0.05400 0.10800 System Sensor P2RL-LF Low Freq A/V 177cd 5 x 0.00000 0.00000 5 x 0.26600 1.33000 System Sensor SRL 15cd 3 x 0.00000 0.00000 3 x 0.04300 0.12900 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 1.567 0 x 0.00000 0 x 0.00000 TOTAL NAC 1 CURRENT 0.000 1.567 OHMs Per 1000FT Length of Wire Volts @ EOL % Drop LINE LOSS CALCULATIONS 14 AWG Solid 3.07 350 22.32 7.02% NAC Circuit 2 System Sensor P2RL 15cd 1 x 0.00000 0.00000 1 x 0.05400 0.05400 System Sensor P2RL-LF Low Freq A/V 177cd 4 x 0.00000 0.00000 4 x 0.26600 1.06400 System Sensor SRL 15cd 2 x 0.00000 0.00000 2 x 0.04300 0.08600 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 1.204 0 x 0.00000 0 x 0.00000 TOTAL NAC 2 CURRENT 0.000 1.204 OHMs Per 1000FT Length of Wire Volts @ EOL % Drop LINE LOSS CALCULATIONS 14 AWG Solid 3.07 375 22.61 5.78% NAC Circuit 3 System Sensor P2RL 15cd 0 x 0.00000 0 x 0.05400 System Sensor P2RL-LF Low Freq A/V 177cd 4 x 0.00000 0.00000 4 x 0.26600 1.06400 System Sensor SRL 15cd 2 x 0.00000 0.00000 2 x 0.04300 0.08600 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 TOTAL NAC 3 CURRENT 0.000 1.150 OHMs Per 1000FT Length of Wire Volts @ EOL % Drop LINE LOSS CALCULATIONS 14 AWG Solid 3.07 400 22.59 5.88% NAC Circuit 4 Booster Panel TRIP 1 x 0.00000 0.00000 1 x 0.01500 0.01500 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 TOTAL NAC 4 CURRENT 0.000 0.015 OHMs Per 1000FT Length of Wire Volts @ EOL % Drop LINE LOSS CALCULATIONS 14 AWG Solid 3.07 150 23.99 0.03% 1.41 Wire Type and AWG Rating Voltage Drop 0.01 1.68 Wire Type and AWG Rating Voltage Drop 1.39 Wire Type and AWG Rating Voltage Drop Wire Type and AWG Rating Voltage Drop Aux Non Resettable 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.000 0 x 0.00000 0 x 0.00000 TOTAL AUX CURRENT 0.000 0.000 OHMs Per 1000FT Length of Wire Volts @ EOL % Drop LINE LOSS CALCULATIONS 0 250 24.00 0.00% Aux Resettable 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.000 0 x 0.00000 0 x 0.00000 TOTAL AUX RESET CURRENT 0.000 0.000 OHMs Per 1000FT Length of Wire Volts @ EOL % Drop LINE LOSS CALCULATIONS 0 24.00 0.00% 1 1 3.047 0.00 Wire Type and AWG Rating Voltage Drop 0.00 Total Standby Load:0.147 Total Alarm Load: Wire Type and AWG Rating Voltage Drop Project: Contractor:Standby Hours:24 Prepared By:Alarm Mins:5 DATE:Derating Factor:1.2 10 Total Standby Current (Amps):0.075 4.991 Total Alarm Current (Amps) Standby Time In Hours:24 0.208 Alarm Minutes / 24 (1.2 Mins) Total Standby AH Required:1.800 1.040 Total Alarm AH Required Total Combined AH Required: Multiply By The Derating Factor: Minimum Battery AmpHours Required: Battery Amp Size Provided: Device Qty Draw Standby Qty Draw Alarm Panel Information FCI HPF902ULADA Booster Panel 1 x 0.07500 0.07500 1 x 0.17500 0.17500 TOTAL PANEL CURRENT 0.07500 0.17500 NAC Circuit 1 System Sensor P2RL 15cd 3 x 0.00000 0.00000 3 x 0.05400 0.16200 System Sensor P2RL-LF Low Freq A/V 177cd 5 x 0.00000 0.00000 5 x 0.26600 1.33000 System Sensor SRL 15cd 2 x 0.00000 0.00000 2 x 0.04300 0.08600 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 1.578 0 x 0.00000 0 x 0.00000 TOTAL NAC 1 CURRENT 0.000 1.578 OHMs Per 1000FT Length of Wire Volts @ EOL % Drop LINE LOSS CALCULATIONS 14 AWG Solid 3.07 350 22.30 7.06% NAC Circuit 2 System Sensor P2RL 15cd 1 x 0.00000 0.00000 1 x 0.05400 0.05400 System Sensor P2RL-LF Low Freq A/V 177cd 4 x 0.00000 0.00000 4 x 0.26600 1.06400 System Sensor SRL 15cd 2 x 0.00000 0.00000 2 x 0.04300 0.08600 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 1.204 0 x 0.00000 0 x 0.00000 TOTAL NAC 2 CURRENT 0.000 1.204 OHMs Per 1000FT Length of Wire Volts @ EOL % Drop LINE LOSS CALCULATIONS 14 AWG Solid 3.07 375 22.61 5.78% 2.84 1.20 System Current Draw - HPF902ULADA BOOSTER PANEL Cayuga Flats Schuler Haas Voltage Drop Warning Threshold %: C Schramm 1/14/2020 3.41 Standby Current Alarm Current 1.39 7.00 Wire Type and AWG Rating Voltage Drop 1.70 Wire Type and AWG Rating Voltage Drop NAC Circuit 3 System Sensor P2RL 15cd 0 x 0.00000 0 x 0.05400 System Sensor P2RL-LF Low Freq A/V 177cd 3 x 0.00000 0.00000 3 x 0.26600 0.79800 System Sensor SRL 15cd 2 x 0.00000 0.00000 2 x 0.04300 0.08600 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0.884 0 x 0.00000 0 x 0.00000 TOTAL NAC 3 CURRENT 0.000 0.884 OHMs Per 1000FT Length of Wire Volts @ EOL % Drop LINE LOSS CALCULATIONS 14 AWG Solid 3.07 300 23.19 3.39% NAC Circuit 4 System Sensor P2RL 15cd 0 x 0.00000 0 x 0.05400 System Sensor P2RL-LF Low Freq A/V 177cd 4 x 0.00000 0.00000 4 x 0.26600 1.06400 System Sensor SRL 15cd 2 x 0.00000 0.00000 2 x 0.04300 0.08600 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 1.15 0 x 0.00000 0 x 0.00000 TOTAL NAC 4 CURRENT 0.000 1.150 OHMs Per 1000FT Length of Wire Volts @ EOL % Drop LINE LOSS CALCULATIONS 14 AWG Solid 3.07 375 22.68 5.52% Aux Non Resettable 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 0 x 0.00000 0 x 0.00000 TOTAL AUX CURRENT 0.000 0.000 OHMs Per 1000FT Length of Wire Volts @ EOL % Drop LINE LOSS CALCULATIONS 0 24.00 0.00% Aux Resettable 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 x 0.00000 0 0 x 0.00000 0 x 0.00000 TOTAL AUX RESET CURRENT 0.000 0.000 OHMs Per 1000FT Length of Wire Volts @ EOL % Drop LINE LOSS CALCULATIONS 0 24.00 0.00% 1 1 Total Standby Load:0.075 Total Alarm Load:4.991 Wire Type and AWG Rating Voltage Drop 0.81 Wire Type and AWG Rating Voltage Drop 1.32 0.00 Wire Type and AWG Rating Voltage Drop 0.00 Wire Type and AWG Rating Voltage Drop S3 Series S3 Series Control Panel Small Addressable Fire Alarm Control Panel Analog and Networking Systems General The Gamewell-FCI®, S3 Series Intelligent Fire Alarm Control Panel provides the latest, innovative high-end processing power. The S3 Series panel is a digital, microprocessor-based system that offers a simple, intuitive solution for the small to mid-sized fire alarm applications. In standalone or network configurations, the S3 Series complies with most fire alarm application requirements. It supports the following types of networks. • Up to 64 nodes using the 7100 Series panel. • Up to 122 nodes using the S3 Series or E3 Series® panels. Use either twisted-pair wire or fiber-optic to network panels at a high-speed 625K baud ARCNET network bus. With flexible Boolean logic, intelligent detection, and Ethernet connectivity, this system provides power and versatility that surpasses comparable, small addressable fire alarm systems. The basic S3 Series configuration consists of an SLP (Smart Loop Panel) main board, LCD-SLP touchscreen display, SLC loop personality modules, and as seven amp power supply. The SLP main board provides either one or two SLC loops in the Class A or B configuration that supports either of the following protocols: • Up to 318 devices per loop using the System Sensor® protocol. If you add a second loop module, it increases the maximum device count to 636 devices. • Up to 126 devices per loop using the Apollo protocol. If you add a second loop module, it increases the maximum device count to 252 devices. FEATURES & BENEFITS • Listed per ANSI/UL® Standard 864 9th Edition • IBC Seismic Certified • Allows one SLC loop (expandable to two loops) that supports either System Sensor or Apollo devices in Class A or Class B (Style 4, 6 or 7) • Supports a network system of up to 122 nodes (includes E3 Series® panels) or up to 64 nodes (includes 7100 Series) •System Sensor supports up to 318 intelligent devices and each SLC loop supports the following - up to 159 detectors - up to 159 modules (expandable to 636 maximum per panel) • Apollo supports up to 126 intelligent detectors and modules per SLC. (Expandable to 252 maximum per panel) • Includes a high resolution (4.3”) (10.92 cm) color touchscreen display • Provides 7.0 amp power supply (120VAC or 240VAC) • Includes four Class B or two Class A built-in Notification Appliance Circuits (NAC) • Provides selectable System Sensor, Cooper-Wheelock, or Gentex™ strobe synchronization • Supports up to 32 serial annunciators (LCD, LED-only, LED Switch) • Offers an Ethernet port for programming, a variety of system reports, and a FocalPoint® Graphic Workstation connectivity • Provides two fully- programmable Form-C contacts for Fire, Trouble, and Supervisory •TimeCap - Saves time and date up to 48 hours without any power or battery • Automatically adjusts to any NAC End-of- Line Resistor (EOL) value (1k-55k ohm) for legacy audible/visual appliances •Removable display can be used as a remote annunciator • Suitable for pre-action deluge applications 2 General Four Class B or two Class A NACs can be wired and synchronized using the System Sensor, Cooper- Wheelock®, or Gentex™ strobes. To retrofit the SLP on the existing audible/visual appliances, the on-board Electronic EOL (EEOL) automatically adjusts to the EOL resistor in the field. A 4.3" (10.92 cm) color touchscreen display screen shows the following: • Events on the system • Status of analog addressable devices • Complete diagnostic fault codes/messages • Five programmable function buttons with LED status for accessibility to the following functions: Application The S3 Series Fire Alarm and Life Safety System is an easy-to-use intelligent fire alarm solution designed for the small to mid-sized buildings. Analog technology delivers the benefits of a simple system installation, while a user-friendly interface makes panel operation and system maintenance quick and intuitive. Smart Panel Programming Using Boolean logic programming, the installer may customize the system to precisely suit the needs of the building owner. Auto-programming allows the installer to instantly locate all the devices on the SLC loop. Simple, Intuitive Display The front panel display provides a user-friendly interface for the operator's control. A 4.3” (10.922 cm) color touchscreen displays system status, event details and service modes. On the front of the panel, six LEDs show the following conditions. Five custom programmable switches allow the user quick access to common functions specific to the building like device disable, output bypass and device status. Perfect for Retrofits The S3 Series is well-suited for retrofit applications. The SLP provides a simple way to upgrade your fire protection system. It is designed to be an upgrade solution for the legacy FCI, 7100 and Gamewell, 602 Series panels. An added feature is the SLP's EEOL. Using EEOL, the installers can automatically identify the EOL for existing audible/visual appliances. Flexibility for Future Growth The S3 Series can be expanded to add a second SLC loop without replacing the entire system. Using the RPT-E3-UTP Network Repeater, you can network up to 64 nodes (122 nodes with the ANX node expander) using either twisted-pair or fiber-optic. The built-in Ethernet port allows the connection to the Gamewell- FCI’s FocalPoint Graphical Workstation. Figure 1 LCD-SLP Display Optional Accessories DACT-E3 - Dialer The Digital Alarm Communication Transmitter sends digital signals over telephone lines to the central station. It connects to the SLP through an RS-485 bus. Using the Contact ID format, the DACT-E3 provides a four-digit account code followed by the code/numbers listed below: • Three-digit Event Code • Two-digit Group Number • Three-digit Contact Number All codes are used to provide specific point identification. The DACT-E3 is compatible with digital alarm communicator receivers (DACRs) that receive the following signaling formats: For more information, refer to the following data sheets: • DACT-E3 Data Sheet, P/N: 9020-0610 RPT-E3-UTP - Network Repeater Card The Network Repeater allows the SLP fire control panels to connect to the broadband network from remote locations. It connects to other networked units using unshielded, twisted-pair wiring. The RPT-E3- UTP is available with two add-on fiber modules: • FML-E3 connects to the network using either 62.5/125 micron multi-mode fiber. • FSL-E3 connects to the network using 9/125 micron single-mode fiber. Refer to the following data sheets: • RPT-E3-UTP Data Sheet, P/N: 9020-0609. • FML-E3/FSL-E3 Data Sheet, P/N: 9021-60783 - Disable/Enable - Trouble Acknowledge - Bypass Output - Alarm Acknowledge - Lamp Test - Custom-defined • Fire • Silenced • Hazard (Gas or CO) • AC Power •Supervisory •Trouble •Contact ID •SIA •3+1 •4+2 3 LCD-7100 - Remote Annunciator The Remote serial display features an 80-character display. The LCD-7100 can be surface or flush- mounted on a standard 4-gang electrical box. You can use up to five LCD-7100 remote annunciators per SLP panel. For more information, refer to the LCD-7100 Data Sheet, P/N: 9020-0486. ASM-16 - Addressable Switch/LED Module There are 16 programmable switches available to perform any function the application requires. Each ASM-16 switch has 3 LEDs fully programmable in red, yellow, and green. These LEDs can be programmed to operate with a certain button press or operate independently as a status signal (e.g. ON, OFF, Activated, etc). Up to 16 ASM-16 modules can be connected to the SLP panel. For more information, refer to the ASM-16 Data Sheet, P/N: 9020-0554. ANU-48 - 48 LED Driver Unit The ANU-48 provides output for eight remote panel switches and 48 remote LEDs for use in a remotely located UL® Listed annunciator enclosure. Up to 16 ANU-48 modules can be connected to the SLP panel. For more information, refer to the ANU-48 Data Sheet, P/N: 9020-0596. Figure 2 illustrates the S3, SLP-BB Cabinet Enclosure. Figure 2 S3, SLP Enclosure Ordering Information SLP-BLK: SLP addressable FACP in black S3, SLP-BB enclosure. Requires either an SLC-PM or an SLC95- PM for SLC loops. SLP-RED: SLP addressable FACP with red door and black S3, SLP-BB backbox. Requires either an SLC-PM or an SLC95-PM for SLC loops. SLP-RED-G: SLP addressable FACP 240VAC power supply with red door and black S3, SLP-BB backbox. Requires either an SLC-PM or an SLC95-PM for SLC loops. SLC-PM: System Sensor Loop Card - 1 loop used for 159 sensors and 159 modules. For use with the S3 panels only. SLC95-PM: Apollo Loop Card-1 loop used for 126 sensors and modules. For use with the S3 panels only. Accessories DACT-E3: Digital Dialer Communicator Transmitter for the S3 or E3 Series. LCD-SLP: LCD Color Touchscreen display with five programmable switches. For use with the S3 Series panels. Remote annunciation requires the E3 Series A2 cabinet. (E3BB-BA2, E3BB-RA2) RPT-E3-UTP: Network repeater card with twisted-pair, fiber connections. Requires either an FML-E3 or an FSL-E3 card. FML-E3: Multi-mode fiber-optic card for one channel on the RPT-E3-UTP. FSL-E3: Single-mode fiber-optic card for one channel on the RPT-E3-UTP. SLP-RB: SLP motherboard For use with the replacement or the retrofit solutions. FLPS-7-RB: SLP 120VAC 7A power supply. For use with the replacement or the retrofit solutions. SLP-RETROFIT: SLP Retrofit Kit for the 7100 B-Slim and IF602 panels. Includes the new door and the mounting plate. Requires the following: S3BB-RB: SLP red cabinet with an inner door for the mounting display behind the locked, plexi-glass door. Requires the following: LCD-7100: Remote Serial LCD Annunciator ASM-16: Remote Programmable Addressable Switch/ LED Module ANU-48: Remote LED Driver Module S3, SLP-BB CABINET OUTER DOOR S3, SLP-BB CABINET BACKBOX 1 2 3 4 14 1/2" W 20 1/8"H 4 1/2" D •SLP-RB •FLPS-7-RB •SLC95-PM •LCD-SLP •SLC-PM •SLP-RB •FLPS-7-RB •SLC95-PM •LCD-SLP •SLC-PM 4 Figure 3 illustrates the various S3 Series configuration options that are available. Figure 3 S3 Series Panel Configuration Options Networked up to 122 panels using twisted- pair wire or fiber optics. FocalPoint Workstation LCD-E3 Remote Annunicator LCD-SLP Color Touchscreen Annunicator LCD-7100 Remote Annunicator ASM-16 LED Switch Control ANU-48 LED Display Driver RS485DACTRS232EthernetRelay: 3 Form CS3 Series Fire Alarm Control Panel MCS-COF Fire/Carbon Monoxide Detector MS-7AF Pull Station AMM-2RIF Dual Input/Output Module Supports up to 636 Velociti devices or 252 XP95 devices DNR Intelligent Duct Detector ASD-PL2F Photo Detector AOM-2RF Relay Module AMM-2IF Mini Monitor Module ASD-LS Laser Detector Local Energy Trip E3 Series Panel Laptop Programming S3 Series Control Panel Technical Specifications 9021-60730 | H | 09/17 ©2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series®, FocalPoint®, Gamewell-FCI®, and System Sensor® are registered trademarks of Honeywell International Inc. Cooper-Wheelock® is a registered trademark of Cooper-Wheelock Corporation. Gentex™ is a trademark of Gentex Corporation. UL® is a registered trademark of Underwriters Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s S3 Series Control Panel and other products available by visiting www.Gamewell-FCI.com SYSTEM Device Loops: Up to two Class A or B, System Sensor units, each loop supports up to 318 device addresses. OR- Apollo units, each loop supports up to 126 device addresses per loop. NAC Circuits: Four Class B or 2 Class A (2.0 A each circuit), 6.0 A total NAC Operating Voltage: 24 VDC NAC Minimum Voltage: 19.5 VDC @ 20.4 V battery voltage SLC Loop Circuit Operating Voltage: 24 V peak-to-peak Input Voltage: 120 VAC, 60 Hz 240 VAC 50-60 Hz Input Current: 120 VAC, 2.75 amps max. 240 VAC, 1.4 amps max. Aux Power (Resettable): Two Auxiliary circuits, 24 VDC, 1.75 A Aux Power Supervised Class 2 Power-Limited (Non-Resettable): (maximum current of 1.75 is shared between two circuits). Base Panel Current Draw: Standby: 0.111 amps Alarm: 0.243 amps Operating Temperature: 32°-120° F (0°-49° C) Relative Humidity: 93% (non-condensing) Battery Charger Voltage: +24 VDC Battery Charger Capacity: 55 A/H batteries (cabinet accommodates 12 A/H batteries) Alarm, Trouble & Supervisory Relay Contacts: Form-C, 2 amps @ 24VDC (resistive) Cabinet Dimensions: S3, SLP-BB Dimensions: 14 1/2”Wx20 1/8”Hx4 1/2” D (36.83W x 51.18 H x 11.43 D cm) S3BB-RB Dimensions: 19 3/8”Wx19 3/8”Hx4.5” D (49.22 W x 49.22 H x 11.43 D) TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (non-condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. STANDARDS The S3 Series Control Panel is designed to comply with the following standard: UL Standard: UL 864 9th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status. UL Listed: S1869 FM Approved MEA FDNY: COA 6162 CSFM: 7165-1703:0176 City of Chicago Approved: Class 1 Reference Certificate of Compliance: VMA 45894-02C ISO 9001 Certification LCD-SLP LCD Touchscreen Annunciator Display GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. ©2013 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60782 Rev. B page 1 of 1 Description The Gamewell-FCI, Liquid Crystal Display, Smart Loop Panel (LCD-SLP) is a touchscreen annunciator display used with the S3 Series System. The LCD-SLP provides an easy-to-use, intuitive interface for the operator’s control. The 4.3” (10.92 cm) color touchscreen display shows the following: • System Status • Service modes • Event details The following identify the LED Indicators that display on the panel. • AC (green) • Supervisory (yellow) • Fire Alarm (red) • Trouble (yellow) • Hazard (blue) • Silenced (yellow) The five fully-programmable front panel switch/LED combi- nations provide a direct access to perform the following tasks: • Device Bypass • Lamp Test • Enable/Disable Groups or Devices The display features the following physical switches. •Menu •System Reset • Five Programmable Switches •Drift Walk Test Installation The LCD-SLP is adaptable for installation in either the S3 or E3® Series cabinets. • S3 Series Cabinets - SLP-BB basic system enclosure - S3BB-BB/S3BB-RB system enclosure • E3 Series ® Cabinets- A2 size cabinet (E3BB-BA2, E3BB-RA2)- A size flush cabinet (E3BB-FLUSH-LCD) Specifications Operating Voltage:24 VDC FWR Operating Current:0.030 amp Alarm Current:0.065 amp Operating Temperature: 32° to 120° F (0° to 49° C) Relative Humidity:0 to 93%,non-condensing at 90° F (32° C) E3 Series® is a registered trademark of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. Features LCD-SLP • Listed per ANSI/UL ® Standard 864 9th Edition. • Provides 4.3” (10.92 cm) color touchscreen display of System Events. • Includes five custom function buttons with LEDs for direct access to system controls. • Offers the following installation options: - Locally mounted in the S3 Series panels. - Remotely mounted in the E3 Series, A2 cabinet or LCD Flush enclosure. • Displays the following six LED indicators: - Alarm - Hazard - Trouble - NAC Silence - Supervisory - AC Power • Shows the Hazard LED to indicate gas, carbon monoxide or other toxic gases. • S3 Series (SLP) supports up to 15 LCD-SLP displays via the RS-485 serial interface. Ordering Information Part Number Description LCD-SLP LCD Touchscreen display unit E3BB-BA2 Remote enclosure with inner door, black, one LCD slot E3BB-RA2 Remote enclosure with inner door, red, one LCD slot E3BB-FLUSH-LCD Remote flush mounting enclosure, black, LCD slot S1869 SIGNALING 7165-1703:0176 DACT-E3 DACT-E3 Digital Alarm Communicator Transmitter Analog and Networking Systems General The Digital Alarm Communicator Transmitter (DACT-E3) is a digital communications circuit. It is an optional component of the following systems. • E3 Series® Expandable Emergency Evacuation System • S3 Series Small Addressable Fire Alarm Control Panel The DACT-E3 sends digital signals over the telephone network that transmits to a central station. This module can be located in the main cabinet or remotely located via a local RS-485 serial interface. The DACT-E3 is compatible with digital alarm communicator receivers (DACRs) that receive the following signaling formats: In addition to the DACT-E3 being compatible with digital signaling formats, the DACT- E3 features numerous formats for communication to a central station. As a digital communicator, the DACT-E3 complies with FCC Part 8, Telecommunication Standards for DC and AC Ringer Equivalence. Installation The DACT-E3 is adaptable for installation in the standard E3 Series and S3 Series System cabinets. Typically, the DACT-E3 module mounts on standoffs on top of the left side of the ILI-MB-E3/ILI95-MB-E3 or SLP (Smart Loop Panel) module. Either unit can be easily connected to the backbox or sub-assembly plate depending on the cabinet module. For instructions on how to install the DACT-E3, refer to the following documents: • E3 Series Expandable Emergency Evacuation Manual, P/N:LS10080-051GF-E • DACT-E3 Installation Instructions, P/N:9000-0581 • S3 Series (Small Addressable Fire Alarm Control Panel) UL Listing Document, P/N:LS10005-051GF-E Ordering Information DACT-E3: Digital Alarm Communicator Transmitter FEATURES & BENEFITS • Listed under UL®® Standard 864, 9th Edition • Transmits and verifies data to the central station • Communicates with the following sub- assemblies via the RS- 485: - E3 Series - ILI-MB-E3 - ILI95-MBE3 - S3 Series, SLP • Sends information in a variety of formats (including full Contact ID) • Offers pre- programmed dialing to the central station phone number • Performs on and off- hook status to the phone lines • Traces proper central station “ACK” and “Kiss-off” tone • Activates hang-up and release phone lines • Compatible with the IPDACT Internet Communicator • SIA DC8 • 3+1 2300 Hz • SIA DCS20 • 4+2 1400 Hz • Ademco Contact ID • 4+2 2300 Hz • 3+1 1400 Hz DACT-E3 Technical Specifications 9020-0610 | L | 09/17 ©2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series® and Gamewell-FCI ® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriters Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s DACT-E3 and other products available by visiting www.Gamewell-FCI.com SYSTEM Operating Voltage: 24 VDC (from the PM-9/ PM-9G power supply) Operating Current: 0.018 amp Alarm Current: 0.018 amp Operating Temperature: 32° to 120° F (0° to 49° C) Relative Humidity: 0 to 93%, non-condensing at 90° F (32° C) TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for opera- tion at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic com- ponents may be adversely affected by extreme tem- perature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. STANDARDS The DACT-E3 is designed to comply with the following standard: UL Standard: UL 864 9th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status. UL Listed: S1869 FM Approved: 3025415 MEA Approved, Fire Dept. of New York: COA# 6077 CSFM: 7165-1703-0125 City of Chicago: Class 1, Class 2 and High Rise City of Denver TG-7FS Cellular alarMCoMMuniCatorfor 3g/4g networks Telguard Cellular Service Telguard Cellular Service provides nationwide digital cellular network coverage for all Telguard units. Telguard’s Communication Center is UL compliant and provides seamless connectivity between the alarm panel, the Telguard family of products and the central station. Telguard Technical Support provides a single point of contact for both cellular service and Telguard product questions. Advanced Reliability • Features the ability to utilize multiple cellular technologies to increase availability and reduce false alarms. • Automatic self-tests with central station notification ensure the cellular system is operating. • Available relay output for tripping the alarm control panel when a trouble condition occurs. Telguard Online Telguard makes adopting cellular easy with a secure Internet portal.  The straightforward web interface allows security dealers and central stations to quickly and efficiently access Telguard based services 24/7.  This advanced tool has multi-level user authorization and provides total account management of UL Listed Telguard cellular alarm communicators. PRODUCT FEATURES Meets UL 864 requirements for sole, primary or backup path communications. Provides RMR protection by leveraging technology that operates on 3G/4G networks. Supports listen-in, two-way voice verification over cellular. Minimizes false alarms by providing dual paths for self-tests. Falls back to 2G (GSM) if a 3G/4G network isn’t available. COmmERCiAl FiRE The Telguard TG-7FS is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the TG-7FS can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS can be installed as the sole path for commercial fire installations.  For existing installations, all landlines can be swapped for a single TG-7FS because of the new sixty minute supervision mode. The TG-7FS can also be installed as a backup path and upgraded to sole path at a later date. TG-7FS Cellular alarMCoMMuniCatorfor 3g/4g networks Telguard, a Division of Telular Corporation • Cumberland Center IV • 3225 Cumberland Blvd • Suite 300 • Atlanta, GA 30339 • USA 800-229-2326, Option 5 • www.Telguard.com • Copyright ©2012 Telular Corporation • All Rights Reserved Radio Transceiver • 3G cellular radio. • GSM 850MHz: Class 4 (2 watts). • GSM 1900MHz: Class 1 (1 watt). • UMTS WCDMA FDD 850/1900MHz. • Antenna: 9” dipole with 2dBi gain, 12 ft of cable and universal mounting bracket. • FCC part 15, 22, 24 and 68 compliant. Physical Details • TG-7FS: 7.5” H x 11.5” W x 3.5” D. • Shipping Weight: 8lbs. • Operating Environment: 0°C to +50°C; up to 95% humidity (non-condensing). Standard Features • Full data reporting. • Automatic self-test (60 min. & daily). • Power supply with battery harness. • Locking, red metal enclosure. • Two programmable supervisory trip outputs. • Alarm format support for SIA2, Contact ID, pulse (3x1, 4x2), modem IIe, & IIIa2 , DMP. • Telephone line monitor built-in, with Standard Line Security. Power • Transmit power: 1.0W-2.0W (maximum allowable). • Power Consumption: 60mA (Standby) 250mA (Transmission). • Transformer: 12VAC, 800mA UL listed plug-in. Ul listings Commercial Fire 864 • Control units & accessories for fire alarm systems Commercial Burglary 365 • Police Station connected burglar alarm units and systems 1610 • Central station burglar alarm units; Line security servcies Residential 985 • Household fire warning systems 122012RevB Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in-building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories • ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. • HGD-0: High gain directional antenna. • EXD-0: External antenna. * For the most current product specifications and UL Listings visit www.Telguard.com. HPF902ULADA Fire Alarm Power Supply h1012cov.jpgDescription The HPF902ULADA Fire Alarm Power Supply from Honeywell Power Products offers the highest value among power sup- plies available today. It delivers 9.0 A of notification appliance circuit power and built-in synchronization for appliances from System Sensor, Gentex, Wheelock, and Faraday. Our design represents the state-of-the-art in fire alarm supplies. Yet for all its sophistication, it is an extremely cost-effective notification power supply. The HPF902ULADA is a 9.0 A notification power expander that provides its own AC power connection, battery charging circuit, and backup battery space, for use with fire and security controls. It is ideal for powering notification appliances required by the Americans with Disabilities Act (ADA). It con- tains a built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. Benefits • Extends and supports power for additional fire alarm devices. • Instantaneous switchover to standby battery (if equipped) when AC fails, maintaining power to all attached devices without intervention. • Strobe signal "passes through" allowing syncing of large systems. • LED lights for quick and easy diagnosis, troubleshooting, and status indication. Features • 9.0 A of notification power. • 24 VDC filtered output voltage. • DIP switches for easy reconfiguration. • Power supply has advanced switch-mode design. • Four power-limited notification outputs: two Class A, or four Class B, or one Class A and two Class B. • Additional continuous auxiliary output. • 3.0 A per output circuit. • Two inputs; two Class B or two Class A. • Ground fault detector/indicator. • Independent trouble relay. • AC loss delay option shuts off power to nonessential high current accessories, such as magnetic door holders. • Built-in synchronization for appliances from System Sensor, Gentex, Wheelock and Faraday. • Stand-alone operation. • Lightweight design adds to ease of installation and reduces shipping costs. • Operates with most polarized, UL-Listed notification devices. • Complies with UL 864, UL 1481, and NFPA 72. • Built-in ANSI cadence pattern output capability. • Connection to local fire control: – May be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. – One unit can be connected to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way to the control panel. • Supervision for a variety of functions, including: –Low AC power. – Low battery condition. – Earth ground fault. – Auxiliary output power limit condition. – EOL supervision trouble or power-limited condition at an output. – Form-C trouble relay. Electrical Specifications • AC input: 120 VAC @ 3.6 A. • Output: 24 VDC @ 9.0 A (9.0 A total from all notification circuits and auxiliary circuit). • Amps per output circuit: 3.0 A. • Current draw of unit on battery: 75 mA standby, 175 mA in alarm. • Auxiliary power circuits: 1. • Notification circuits: 4. • Output configuration options: 2 Class A (Style Z); 4 Class B (Style Y); or 1 Class A and 2 Class B. • Notification circuit output: 20.4 to 27.3 VDC @ 3.0 A each. • Inputs: 2, with configuration 2 Class B or 2 Class A. • Input voltage range: 9 – 32 VDC. • Battery charging capacity: 33.0 AH. • Ambient temperature rating: 32°F to 120°F (0°C to 49°C). • Relative humidity: 85% non-condensing maximum. Mechanical Specifications • Dimensions: 16.0" H x 12.25" W x 3.0" D (cm: 40.64 H x 30.88 W x 7.62 D). • Indicator lights: AC Power On (green), Battery Trouble (yellow), Ground Fault (yellow), Aux Trouble (yellow), Output Troubles (1 – 4, yellow). Automation and Control Solutions Honeywell 12 Clintonville Road 1(877) HPP-POWR Northford, CT 06472-1610 hpp_techserv@honeywell.com www.honeywellpower.com This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. DH-1012:B May 2010 Made in the U.S.A. ® U.S. Registered Trademark © 2010 Honeywell International Inc. Page 2 of 2 Listings Listings and approvals below apply to the basic HPF902ULADA panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: file S6677 • CSFM: 7300-1637 PS SERIESTERMINALS: (mm) DIMENSIONS: inch (mm)PERFORMANCE SPECIFICATIONS Nominal Voltage 12 volts (6 cells) Nominal Capacity 20-hr. (70mA to 10.50 volts) 10-hr. (130mA to 10.50 volts) 5-hr. (240mA to 10.20 volts) 1-hr. (850mA to 9.00 volts) 1.40 AH 1.30 AH1.20 AH 0.85 AH Approximate Weight 1.20 lbs. (0.54 kg) Internal Resistance (approx.) 100.0 milliohms Max Short-Duration Discharge Current (10 Sec.)14.0 amperes Shelf Life (% of nominal capacity at 68°F (20°C)1 Month 3 Month 6 Month 97% 91% 83% Operating Temperature RangeCharge Discharge 5°F (-15°C) to 122°F (50°C) -4°F (-20°C) to 140°F (60°C) Case ABS Plastic Power Sonic Chargers PSC-12300A-C PSC-12300-PC www.power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. © 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.All data subject to change without notice. E&O.E CORPORATE HEADQUARTERS (USA AND INTERNATIONAL EXCLUDING EMEA) Power-Sonic Corporation 7550 Panasonic Way, San Diego, California 92154 T: +1 (619) 661 2020 F: +1 (619) 661 3650 E: customer-service@power-sonic.com POWER-SONIC EUROPE LIMITED (EMEA – EUROPE, MIDDLE EAST AND AFRICA) 3 Buckingham Square, Hurricane Way, Wickford, Essex SS11 8YQ T: +44 (0)1268 560686 F: +44 (0)1268 560902 E: salesEMEA@power-sonic.com General Purpose Fire & SecurityEmergency Lighting MH20845 ® Sealed Rechargeable MODEL PS-1212 12 Volt 1.4 Amp. Hr. Battery www.power-sonic.com BATTERYMUSTBEREC YCLEDPb NONSPILLABLE L HT H W Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. L: 3.78 (96) W: 1.69 (43) H: 2.04 (52) HT: 2.28 (58) L: 3.78 (96) W: 1.69 (43) H: 2.04 (52) HT: 2.28 (58) Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. FEATURES •Absorbent Glass Mat (AGM) technology for superior performance •Valve regulated, maintenance free spill proof construction •Power/volume ratio yielding excellent energy density •Rugged vibration and impact resistant ABS case and cover •Gas recombination technology •5 year design life APPROVALS •Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certifi ed •U.L. recognized •ISO9001:2015 – Quality management systems Medical Rev1: 11/18PS-1212 12V 1.4 AH @ 20-hr.12V 1.3 AH @ 10-hr. Rechargeable Sealed Lead Acid Battery PS – General Purpose Series Torque – Not Applicable 4.751.56.35 3.2 2.5 0.8F1: Quick disconnect tabs, 0.187" x 0.032" – Mate with AMP. INC. FASTON “187” series PS SERIESwww.power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. © 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.All data subject to change without notice. E&O.E CORPORATE HEADQUARTERS (USA AND INTERNATIONAL EXCLUDING EMEA) Power-Sonic Corporation 7550 Panasonic Way, San Diego, California 92154 T: +1 (619) 661 2020 F: +1 (619) 661 3650 E: customer-service@power-sonic.com POWER-SONIC EUROPE LIMITED (EMEA – EUROPE, MIDDLE EAST AND AFRICA) 3 Buckingham Square, Hurricane Way, Wickford, Essex SS11 8YQ T: +44 (0)1268 560686 F: +44 (0)1268 560902 E: salesEMEA@power-sonic.com SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE Capacity Retention Ratio (%)Standing Period (Months) 100 80 60 40 00 2 4 6 8 10 12 14 16 18 20 40oC(104oF) 30oC(86oF)20oC(68oF) 5oC (41oF) Charging is not necessary unless 100% of capacity is required. Charging beforeuse is necessaryto help recoverfull capacity. 100 80 60 40 20 0 012345 Ambient Temperature 20˚C (68˚F) Float Charging Voltage2.25 - 2.30 V/Cell Retention Capacity (%)Years SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE Capacity Retention Ratio (%)Standing Period (Months) 100 80 60 40 00 2 4 6 8 10 12 14 16 18 20 40oC(104oF) 30oC (86oF)20oC (68oF) 5oC(41oF) Charging is not necessary unless 100% of capacity is required. Charging beforeuse is necessaryto help recoverfull capacity. 100 80 60 40 20 0 012345 Ambient Temperature 20˚C (68˚F) Float Charging Voltage 2.25 - 2.30 V/Cell Retention Capacity (%)Years SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE CHARGING Cycle Applications: Apply constant voltage charge at 2.35v/c – 2.45v/c (14.1 – 14.7v for 12v Monobloc) at 20°C. Initial charging current should be set at less than 0.25C Amps. Switch to fl oat charge to avoid overcharging. “Float” or “Stand-By” Service: Apply constant voltage charge of 2.25v/c – 2.30v/c (13.5 to 13.8 volts for 12v Monobloc at 20°C. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Temperature Compensation: Charging Voltage for both Cyclic and Standby applications should be regulated in relation to ambient temperature. As temperature rises charging voltage should be reduced to prevent overcharge and increased as temperature falls to avoid undercharge. For further charging information including temperature compensation factors, see Power Sonic Technical Manual/ Power Sonic Charger specifi cations. CHARGERS Power Sonic offers a wide range of chargers suitable for batteries with a variety of capacities. Please refer to our website for more information on our switch mode and transformer type chargers. Please contact our technical department for advice if you have diffi culty in locating a suitable charger. FURTHER INFORMATION Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS), ISO certifi cation, etc. APPLICATIONS •General purpose •Emergency lighting •Medical •Fire and security PS-1212 12V 1.4 AH @ 20-hr.12V 1.3 AH @ 10-hr. Rechargeable Sealed Lead Acid BatteryPS – General Purpose Series Rev1: 11/18 PS SERIESTERMINALS: (mm) DIMENSIONS: inch (mm)PERFORMANCE SPECIFICATIONS Nominal Voltage 12 volts (6 cells) Nominal Capacity 20-hr. (350mA to 10.50 volts) 10-hr. (650mA to 10.50 volts) 5-hr. (1.2A to 10.20 volts) 1-hr. (4.5A to 9.00 volts) 7.00 AH 6.50 AH 6.00 AH4.50 AH Approximate Weight 4.80 lbs. (2.18 kg) Internal Resistance (approx.) 23.0 milliohms Max Short-Duration Discharge Current (10 Sec.)70.0 amperes Shelf Life (% of nominal capacity at 68°F (20°C)1 Month 3 Month 6 Month 97% 91% 83% Operating Temperature Range Charge Discharge 5°F (-15°C) to 122°F (50°C) -4°F (-20°C) to 140°F (60°C) Case ABS Plastic Power Sonic Chargers PSC-12800A-C PSC-121000-PC www.power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. © 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.All data subject to change without notice. E&O.E CORPORATE HEADQUARTERS (USA AND INTERNATIONAL EXCLUDING EMEA) Power-Sonic Corporation 7550 Panasonic Way, San Diego, California 92154 T: +1 (619) 661 2020 F: +1 (619) 661 3650 E: customer-service@power-sonic.com POWER-SONIC EUROPE LIMITED (EMEA – EUROPE, MIDDLE EAST AND AFRICA) 3 Buckingham Square, Hurricane Way, Wickford, Essex SS11 8YQ T: +44 (0)1268 560686 F: +44 (0)1268 560902 E: salesEMEA@power-sonic.com General Purpose Fire & SecurityEmergency Lighting MODEL PS-1270 F1 12 Volt 7.0 Amp. Hr. Warning: Risk of fire, explosion, or burns.Do not disassemble, heat above 60 C, or incinerate. Rechargeable Sealed Lead-Acid BatteryDC power, constant voltage chargeCycle use: 14.4 - 15.0V(20 C)Standby use: 13.5 - 13.8V(20 C)Initial current: 2.1A MAX 801334001000Sealed RechargeableBattery 120070260211 L HT H W Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. L: 5.95 (151) W: 2.56 (65) H: 3.70 (94) HT: 3.86 (98) L: 5.95 (151) W: 2.56 (65) H: 3.70 (94) HT: 3.86 (98) Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions. All data subject to change without notice. FEATURES •Absorbent Glass Mat (AGM) technology for superior performance •Valve regulated, maintenance free spill proof construction •Power/volume ratio yielding excellent energy density •Rugged vibration and impact resistant ABS case and cover •Gas recombination technology •5 year design life APPROVALS •Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certifi ed •U.L. recognized •ISO9001:2015 – Quality management systems Medical Rev1: 11/18PS-1270 12V 7.0 AH @ 20-hr.12V 6.5 AH @ 10-hr. Rechargeable Sealed Lead Acid Battery PS – General Purpose Series OR Torque – Not Applicable 4.751.56.35 3.2 2.5 0.8F1: Quick disconnect tabs, 0.187" x 0.032" – Mate with AMP. INC. FASTON “187” series Torque – Not Applicable 6.351.57.95 3.4 2.5 0.8F2: Quick disconnect tabs, 0.250" x 0.032" – Mate with AMP. INC FASTON “250” series PS SERIESwww.power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. © 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.All data subject to change without notice. E&O.E CORPORATE HEADQUARTERS (USA AND INTERNATIONAL EXCLUDING EMEA) Power-Sonic Corporation 7550 Panasonic Way, San Diego, California 92154 T: +1 (619) 661 2020 F: +1 (619) 661 3650 E: customer-service@power-sonic.com POWER-SONIC EUROPE LIMITED (EMEA – EUROPE, MIDDLE EAST AND AFRICA) 3 Buckingham Square, Hurricane Way, Wickford, Essex SS11 8YQ T: +44 (0)1268 560686 F: +44 (0)1268 560902 E: salesEMEA@power-sonic.com SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE Capacity Retention Ratio (%)Standing Period (Months) 100 80 60 40 00 2 4 6 8 10 12 14 16 18 20 40oC(104oF) 30oC(86oF)20oC(68oF) 5oC (41oF) Charging is not necessary unless 100% of capacity is required. Charging beforeuse is necessaryto help recoverfull capacity. 100 80 60 40 20 0 012345 Ambient Temperature 20˚C (68˚F) Float Charging Voltage2.25 - 2.30 V/Cell Retention Capacity (%)Years SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE Capacity Retention Ratio (%)Standing Period (Months) 100 80 60 40 00 2 4 6 8 10 12 14 16 18 20 40oC(104oF) 30oC (86oF)20oC (68oF) 5oC(41oF) Charging is not necessary unless 100% of capacity is required. Charging beforeuse is necessaryto help recoverfull capacity. 100 80 60 40 20 0 012345 Ambient Temperature 20˚C (68˚F) Float Charging Voltage 2.25 - 2.30 V/Cell Retention Capacity (%)Years SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE CHARGING Cycle Applications: Apply constant voltage charge at 2.35v/c – 2.45v/c (14.1 – 14.7v for 12v Monobloc) at 20°C. Initial charging current should be set at less than 0.25C Amps. Switch to fl oat charge to avoid overcharging. “Float” or “Stand-By” Service: Apply constant voltage charge of 2.25v/c – 2.30v/c (13.5 to 13.8 volts for 12v Monobloc at 20°C. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Temperature Compensation: Charging Voltage for both Cyclic and Standby applications should be regulated in relation to ambient temperature. As temperature rises charging voltage should be reduced to prevent overcharge and increased as temperature falls to avoid undercharge. For further charging information including temperature compensation factors, see Power Sonic Technical Manual/ Power Sonic Charger specifi cations. CHARGERS Power Sonic offers a wide range of chargers suitable for batteries with a variety of capacities. Please refer to our website for more information on our switch mode and transformer type chargers. Please contact our technical department for advice if you have diffi culty in locating a suitable charger. FURTHER INFORMATION Please refer to our website www.power-sonic.com for a complete range of useful downloads, such as product catalogs, material safety data sheets (MSDS), ISO certifi cation, etc. APPLICATIONS •General purpose •Emergency lighting •Medical •Fire and security PS-1270 12V 7.0 AH @ 20-hr.12V 6.5 AH @ 10-hr. Rechargeable Sealed Lead Acid BatteryPS – General Purpose Series Rev1: 11/18 ASD-PL2F/ASD-PTL2F ASD-PL2FR Velociti® Series 3 Detectors Photoelectric Detectors Addressable Devices Photoelectric Detector Description The Gamewell-FCI, Velociti® Series 3 intelligent photoelectric detectors with integral communication provide point location for alarm communication and selective maintenance. Designed in a modern bright white color, the Velociti Series 3 is aesthetically pleasing for today's contemporary buildings. The Velociti Series 3 smoke detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations. The photoelectric detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. The Gamewell-FCI, ASD-PL3 photoelectric detector's re-designed optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The sensitivity of Velociti series detectors can be programmed using the control panel software to suit the environment. The ASD-PL3R photoelectric detector is also remote test capable that may be used with a DNR (DNRW) duct smoke detector housing. The ASD-PTL3 multi- sensor detector offers either photoelectric detection or thermal detection through dual electronic thermistors at 135°F fixed temperature thermal sensing. For legacy installations, service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility. Service models are designated by the -IV part number after the detector model. Note: Although the E3 Series® and S3 Series panels support both the Velociti® and CLIP™ protocols, the GWF-7075 panel does not support the CLIP protocol. To obtain a complete list of panels that are listed to Velociti Series 3 detectors, refer to the Compatibility Addendum for Gamewell-FCI Manuals, P/N:9000-0427-L8. FEATURES & BENEFITS • Complies with UL® Standard 268 7th Edition • Designed with a new profile to offer modern and improved aesthetics • Contains a built-in functional test switch activated by external magnet • Supports a low standby current • Provides rotary address switches (01-159) • Supplies optional relay, isolator, or sounder bases (standard or low frequency) • Includes dual LEDs for 360° visibility • Offers expanded color options 2 Ordering Information NOTE: "-IV" suffix indicates Ivory color model. NOTE: "-BL" suffix indicates Black color model. NOTE: “WH” suffix indicates Bright White color model. ASD-PL3: Photoelectric smoke detector, bright white, Velociti ASD-PL3R: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, bright white, Velociti ASD-PTL3: Photoelectric smoke detector with thermal sensing, bright white, Velociti ASD-PL3-IV : Photoelectric smoke detector, ivory, Velociti/ CLIP ASD-PL3R-IV: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, ivory, Velociti/CLIP ASD-PTL3-IV : Photoelectric smoke detector with thermal sensing, ivory, Velociti/CLIP Intelligent Bases For details on intelligent bases, refer to Data Sheet P/N: 9021-60540. Note: “IV” suffix indicates Flashscan and CLIP devices. “WH” suffix indicates bright white B501-WHITE: 4” Flangeless mounting base, bright white B501-WHITE-BP: 4” Flangeless mounting base bulk pack, bright white B501-IV: 4” Flangeless mounting base, ivory B300-6: 6” Flanged mounting base, bright white B300-6-IV: 6” Flanged mounting base, ivory B300-6-BP: 6” Flanged mounting base bulk (Pack of 10) B200SR-WH: Standard sounder base, bright white B200SR-IV: Standard sounder base, ivory B200S-WH: Intelligent addressable sounder base, bright white B200S-IV: Intelligent addressable sounder base, ivory B200SR-LF-WH: Standard low frequency sounder base, bright white B200SR-LF-IV: Standard low frequency sounder base, ivory B200S-LF-WH: Intelligent addressable low frequency sounder base, bright white B200S-LF-IV: Intelligent addressable low frequency sounder base, ivory B224RB-WH: Relay base, bright white B224RB-IV: Relay base, ivory B224BI-WH: Isolator base, bright white B224BI-IV: Isolator base, ivory DNR: Intelligent duct detector housing, non-relay DNRW: Intelligent duct detector housing, non-relay, watertight Ordering Information Accessories SMB600: Surface Mounting Kit (flanged) TR300: Accessory Flange Ring for B300 6” Base, bright white TR300-IV: Accessory Flange Ring for B300 6” Base, ivory RA100Z: Remote LED annunciator, 3-32 VDC The annunciator mounts to a U.S. single-gang electrical box. For use with B501 and B300-6. CK300: Bright White detector kit (Pack of 10) CK300-IR: White, detector color kit for use with MCS-COF Series Detectors. (Pack of 10) CK300-IV: Ivory, detector color kit. (Pack of 10) CK300-IR-IV: Ivory, detector color kit for use with MCSCOF Series detectors. (Pack of 10) CK300-BL: Black detector kit. (Pack of 10) CK300-IR-Bl: Black, detector color kit for use with MCSCOF Series detectors. (Pack of 10) M02-04-01: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows the installation and/ or removal of the detector heads from the bases in high ceiling applications. XP-4: Extension pole for XR2B. Shipped with three, 5-foot (1.524,m) sections. Velociti® Series 3 Detectors Technical Specifications 9020-0617 | K | 04/2018 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series®, Velociti® and Gamewell-FCI® are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s Velociti® Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com SYSTEMS Photoelectric Intelligent Detector: Physical Specifications Height: 2.0 inches (51 mm) installed in B300-6 base Diameter: 6.1 inches (15.49 cm) installed in B300-6 base 4 inches (10.16 cm) installed in B501 base Shipping Weight: 3.4 oz (96.4 g) Operating Temperature Range: Photo: 32° F to 122° F (0° C to 50° C) Photo in Duct Applications: -4° F to 158° F (-20° C to 70° C) Photo with Thermal: 32° F to 100° F (0° C to 38° C) Operating Humidity Range: 10% to 93% non-condensing Rate-of-Rise Detection: Responds to greater than 15°F/minute or 135°F (8.3° C/minute or 57°C Air Velocity Range: 0 to 4,000 ft/min (0 to 1219.2 m/min) Electrical Specifications Voltage Range: 15 to 32 VDC Standby Current (@ 24 VDC): 200 UA (one communication every 5 seconds with green LED enabled) Max Alarm Current (max.): 2 mA @ 24 VDC (one communication every 5 seconds with red LED enabled) Max Current (max.): 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED enabled) Isolator Load Rating: 0.0063 STANDARDS The Velociti® Series 3 Photoelectric Detectors are designed to comply with the following standard: UL Standard: UL 268 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2332 FM: 3023594 MEA FDNY: COA-219-02-E Vol. VI CSFM: 7272-1703:0501 ISO 9001 Certification Thermal Detector Velociti® Series 3 Detectors Thermal Detectors Addressable Devices Description The Gamewell-FCI, Velociti® Series 3 intelligent thermal detectors with integral communication provide point location for alarm communication and selective maintenance. Designed in a modern bright white color, the Velociti Series 3 is aesthetically pleasing for today's contemporary buildings. The Velociti Series 3 heat detectors are intelligent addressable detectors with point ID capability that enable each detector address to be set with rotary address switches providing exact device locations. The thermal detector continually monitors the detected temperature and reports it to the fire alarm control panel. The modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. Velociti Series 3 thermal detectors provide cost-effective, intelligent property protection using the following single thermistor: • ATD-L3 offers 135°F fixed thermal detection. • ATD-L3R offers 135°F fixed and rate-of-rise thermal detection. • ATD-L3H provides fixed high-temperature detection at 190°F . For legacy installations, service detectors are available in the classic ivory color that will operate in both Velociti and CLIP protocol for backwards compatibility. Service models are designated by the -IV part number that appears after the detector model. Note: The E3 Series® and S3 Series panels support both the Velociti® and CLIP™ protocols, and the GWF-7075 panel supports only the Velociti® protocol. To obtain a complete list of panels that are listed to Velociti Series 3 detectors, refer to the Compatibility Addendum for Gamewell-FCI Manuals, P/N:9000-0427-L8. FEATURES & BENEFITS • Complies with UL® 268 7th Edition • Designed with a new profile to offer modern and improved aesthetics • Contains a built-in functional test switch activated by an external magnet • Supports a low standby current • Provides rotary address switches (01-159) • Supplies optional relay, isolator, or sounder bases (standard or low frequency) •Includes dual LEDs used for 360° visibility • Offers expanded color options 2 Ordering Information NOTE: "-IV" suffix indicates Ivory color model. NOTE: "-BL" suffix indicates Black color model. NOTE: “WH” suffix indicates Bright White color model. ATD-L3: Thermal heat detector, 135°F fixed, bright white, Velociti ATD-L3-IV: Thermal heat detector, 135°F fixed, ivory, Velociti/CLIP ATD-L3R: Thermal heat detector, 135°F rate of rise, bright white, Velociti ATD-L3R-IV: Thermal heat detector, 135°F rate of rise, ivory, Velociti/CLIP ATD-L3H: Thermal heat detector, 190°F high temp, bright white, Velociti ATD-L3H-IV: Thermal heat detector, 190°F high temp, ivory, Velociti/CLIP Intelligent Bases For details on intelligent bases, refer to Data Sheet P/N: 9021-60540. B501-White: 4" Flangeless mounting base, bright white B501-White-BP: 4" Flangeless mounting base bulk pack, bright white B501-IV: 4" Flangeless mounting base, ivory B501-BL 4" Flangeless mounting base, B300-6: 6" Flanged mounting base, bright white B300-6-IV: 6" Flanged mounting base, ivory B300-6-BP: 6" Flanged mounting base bulk pack B200SR-WH: Standard sounder base, bright white B200SR-IV: Standard sounder base, ivory B200S-WH: Intelligent addressable sounder base, bright white B200S-IV: Intelligent addressable sounder base, ivory B200SR-LF-WH: Standard low frequency sounder base, bright white B200SR-LF-IV: Standard low frequency sounder base, ivory B200S-LF-WH: Intelligent addressable low frequency sounder base, bright white B200S-LF-IV: Intelligent addressable low frequency sounder base, ivory B224RB-WH: Relay base, bright white B224RB-IV: Relay base, ivory B224BI-WH: Isolator base, bright white B224BI-IV: Isolator base, ivory Ordering Information Accessories SMB600: Surface Mounting Kit (flanged) TR300: Accessory Flange Ring for B300 6" Base, bright white TR300-IV: Accessory Flange Ring for B300 6" Base, ivory RA100Z: Remote LED annunciator, 3-32 VDC The annunciator mounts to a U.S. single-gang electrical box. For use with B501 and B300-6. CK300: Bright White detector kit (Pack of 10) CK300-IR: White, detector color kit for use with MCS-COF Series Detectors. (Pack of 10) CK300-IV: Ivory, detector color kit. (Pack of 10) CK300-IR-IV: Ivory, detector color kit for use with MCS- COF Series detectors. (Pack of 10) CK300-BL: Black detector kit (Pack of 10) CK300-IR-Bl: Black, detector color kit for use with MCS- COF Series detectors. (Pack of 10) M02-04-01: Detector test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows the installation and/or removal of the detector heads from the bases in high ceiling applications. XP-4: Extension pole for XR2B. Shipped with three, 5- foot (1.524,m) sections. Velociti® Series 3 Detectors Technical Specifications 9020-0620 | G | 04/2018 ©2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx E3 Series®, Velociti® and Gamewell-FCI® are registered trademarks and CLIP™ is a trademark of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s Velociti® Series 3 Detectors and other products available by visiting www.Gamewell-FCI.com SYSTEMS Thermal Intelligent Detector Physical Specifications Height: 2.0 inches (51 mm) installed in B300-6 base Diameter: 6.1 inches (15.6 cm) installed in B300-6 base 4 inches (10.2 cm) installed in B501 base Shipping Weight: 3.4 oz (95 g) Operating Temperature Range: Thermal 135° F fixed: -4° F to 100° F (-20° C to 38° C) Thermal 135° F rate-of-rise: -4° F to 100° F (-20° C to 38° C) Thermal 190° F rate-of-rise: -4° F to 135° F (-20° C to 57° C) Operating Humidity Range: 10% to 93% non- condensing Rate-of-Rise Detection: : Responds to greater than 15°F/minute or 135°F (8.3° C/minute or 57°C Electrical Specifications Voltage Range: : 15 to 32 VDC Standby Current (@ 24 VDC): 200 uA (one communication every 5 seconds with green LED enabled) Max Alarm Current (max.): : 2 mA @ 24 VDC (one communication every 5 seconds with red LED enabled) Max Current (max.): : 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED enabled) Isolator Load Rating: : 0.0063 STANDARDS The Velociti® Series 3 Thermal Detectors are designed to comply with the following standard: UL Standard: UL 268 AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2332 FM: 3023594 MEA-FDNY: 219-02-E Vol. VI CSFM: 7270-1703-0502 ISO 9001 Certification MS-7 Series MS-7 Series Manual Fire Alarm Pull Stations Addressable Devices General The Gamewell-FCI, MS-7 Series manual fire alarm pull stations are available in a wide variety of configurations. The pull stations comply with the Americans with Disabilities Act (ADA) 5-lb. maximum pull force requirement. Operating instructions and Braille text are engraved in the handle. All pull stations include a key lock/reset which is keyed alike with the Gamewell-FCI fire alarm control panels and other manual fire alarm pull stations. MS-7AF Velociti Addressable Station The MS-7AF Velociti® Series addressable station is a double action pull station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels. Activation of the pull station causes its assigned address to register at the fire alarm control panel. The door contains an LED which flashes green in normal condition and lights steady red when the station has been activated.* The station features screw terminals. MS-7ASF Velociti Addressable Station The MS-7ASF Velociti® Series addressable pull station is a single action station designed for installation in the signaling line circuit of Gamewell-FCI analog addressable control panels. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steady red when the pull station is activated.* The station features screw terminals. The Velociti® Series pull stations use a communication protocol that substantially increases the speed of communication between the sensors and certain Gamewell-FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel’s microprocessor stops the group poll and focuses on the single device. The net effect offers a response speed up to five times greater than earlier designs. MS-7 Double Action Station The MS-7 double action pull station is used with conventional fire alarm control panels. It features a set of single pole contacts and screw terminals for connection to an initiating circuit. FEATURES & BENEFITS • Addressable stations compatible with all Gamewell-FCI analog addressable fire alarm controls • Conventional stations suitable for use with any UL® Listed control panel • The pull stations (MS- 7LOB) are Listed for outdoor applications • Complies with ADA pull force requirements • Offers surface or semi- flush mounting • Shock and vibration resistant • Both single and double action pull stations available • Includes a tumbler lock for test and reset keyed alike with analog addressable fire alarm controls *Only the red LED is operative in panels that do not operate in Velociti mode 2 MS-7S Single Action Station The MS-7S single action pull station is used with conventional fire alarm control panels. It features a set of single pole contacts and wire leads for connection to an initiating circuit. MS-7SP Double Action Station The MS-7SP is a double action pull station similar to the MS-7 station, with the additional feature of including both English and Spanish instructions molded into the unit. MS-7LR Dual-action Agent Release Station The MS-7LR is designed for use with the Gamewell-FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems. It features a set of single pole contacts and screw terminals used to connect to an initiating circuit. MS-7LRA Agent Release Station with Abort The MS-7LRA is designed for use with the Gamewell- FCI fire alarm control panels with releasing capabilities and Flex Series releasing systems where system abort capabilities are required. It consists of the following: • An MS-7LR mounted on a plate with an abort switch • LED indicators that signal system normal and system activated status MS-7LOB Double Action Station (Listed for Outdoor Applications) The MS-7LOB station must be mounted on a Model SB-I/O backbox. In retrofit applications, the pull station is UL Listed for use with the WP-10 backbox. It is intended for use with conventional control panels and has a set of single pole contacts and screw terminals. Mounting The MS-7 interior pull stations may be surface mounted or semi-flush mounted on a standard double-gang, or 4-inch (10.2 cm) square electrical box. An optional trim ring (BG12TR) may also be used for semi-flush mounting. NYC-Plate The NYC-Plate provides the backplate for the manual pull station. (See Figure 1). Figure 1 NYC-Plate Ordering Information MS-7: Double action station MS-7AF**: Velociti addressable double action station MS-7ASF**: Velociti addressable single action station MS-7S: Single action station, wire leads MS-7SP: Double action station, English and Spanish instructions MS-7LR: Agent release station, dual-action MS-7LRA: Agent release station with abort switch, LED indicators, dual- action MS-7LOB: Double action station, outdoor use (Includes SB-I/O - Indoor/outdoor use backbox) SB-I/O: Indoor/outdoor use backbackbox SB-10: Surface backbox BG12TR: Trim ring for semi-flush mount, plastic NY-PLATE: NYC backplate for manual pull station **For use with the Gamewell-FCI analog addressable control panels only. MS-7 Series Technical Specifications 9020-0616 | F | 11/17 ©2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit: http://www.gamewell- fci.com/en-US/ documentation/Pages/ Listings.aspx LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. Velociti® and Gamewell-FCI are registered trademarks of Honeywell International Inc. UL® is a registered trademark of Underwriter’s Laboratories Inc. This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.honeywell.com For more information Learn more about Gamewell-FCI’s MS-7 Series and other products available by visiting www.Gamewell-FCI.com SYSTEMS Material: Lexan® Contact Ratings: 0.25 amps. @ 30 VAC/VDC (resistive) Dimensions: 5 5/8” H x 4 1/4” W x 1 1/4” D (14 x 10.1 x 3.2 cm) Operating Temperature: (MS-7AF, MS-7ASF): 32° to 120° F (0° to 49° C) (MS-7LOB): -30° to 150° F (-35° to 66° C) Relative Humidity : (MS-7AF, MS-7ASF): 10 to 93% (non-condensing) (MS-7LOB): 85% ± 5% @ 86° ± 3.6° (30° ± 2° C) Alarm Current: .0030 amp. 0.007 for LED Supervisory Current: (MS-7AF, MS-7ASF): .00030 amps. TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. STANDARDS The MS-7 Series is designed to comply with the following standard: UL Standard: UL 864 9th Edition AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S2465 FM: 3023594 MEA FDNY: 67-02-E Vol. VII CSFM: 7160-1703:0119 7160-1703:0170 7160-1703:0109 ISO 9001 Certification GAMEWELL-FCI12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.©2016 by Honeywell International Inc. All rights reserved www.gamewell-fci.com 9021-60929 Rev. A page 1 of 4 Indoor Selectable-Output Horns, Strobes, and Horn Strobes for Wall Applications L-Series Indoor Horns, Strobes, and Horn Strobes APPROVED FM SIGNALING PENDING Description The L-Series audible visible notification products offer the most versatile and easy-to-use line of horns, strobes, andhorn strobes in the industry. In addition, this product includes lower current draws and a modern aestheticdesign which reduce installation times and maximize prof- its. The following devices offer a variety of design options,so that the L-Series can be used for any application requirement. • White and red plastic housings. • Standard and small footprint devices. • Plain, FIRE, and FUEGO-printed devices. Similar to the entire L-Series product line, the wall-mounthorns, strobes, and horn strobes include a variety of fea- tures that increase their application versatility while simpli-fying the installation. All devices offer a plug-in design so that there is minimal intrusion into the backbox. These fea-tures make installations fast and foolproof while eliminating costly and time-consuming ground faults. To further simplify the installation and protect devices fromconstruction damage, the L-Series uses a mounting plate for all standard and compact models that include an on-board shorting spring. This feature allows Installers to test wiring continuity before the device is installed. Installers can also easily adapt devices to suit a widerange of application requirements using the following fea-tures: • Field-selectable candela settings. • Automatic selection of 12- or 24-volt operation. • Rotary switch for horn tones with two volume selections. L-Series Specifications Architect/Engineer Specifications General The L-Series standard horns, strobes, and horn strobes shall mount to any of the following enclosures: • standard 2 x 4 x 1 7/8-inch backbox • standard 4 x 4 x 1 1/2-inch backbox • 4-inch octagon backbox • double-gang backbox The L-Series compact products shall mount to a single- gang 2 x 4 x 1 7/8-inch backbox. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, the L-Series products, when used with the Sync•Circuit, Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. Features • Listed for wall mounting only. • Offers small profile devices for horns and horn strobes. • Provides an automatic selection of 12- or 24-volt operation at 15 and 30 candela. • Supports a rotary switch for horn tone and two volume selections. • Produces horn rated at 88+ dBA at 16 volts. • Uses field-selectable candela settings on wall units: - 15 - 30 - 75 - 95 - 110 - 135 - 185 • Includes a mounting plate for all standard and all com- pact wall units. • Contains a mounting plate with a shorting spring that checks the wiring continuity before device installation. • Features a plug-in design with minimal intrusion into the backbox. • Designed with a tamper-resistant construction. • Built with an updated modern design. • Supports electrical compatibility with the existing SpectrAlert and the SpectrAlert Advance products. • Compatible with System Sensor synchronization protocol. Wall Horns/Horn Strobes GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118page 2 of 4 www.gamewell-fci.com 9021-60929 Rev. A L-Series Specifications (Continued) Architect/Engineer Specifications (Continued) General (Continued) When it is used with the Sync•Circuit Module, the following occur: • 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts. • 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.The Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn strobes shall have the following field-selectable candela settings:•15•30•75•95 •110 •135 •185 StrobeThe strobe shall be an L-Series Model _______ listed to UL Standard 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appli- ances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe CombinationThe horn strobe shall be an L-Series Model _______ listed to UL Standard 1971 and UL Standard 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act require- ments for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audible options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization ModuleThe module shall be a Sync•Circuit model MDL3 listed to UL Standard 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch backbox. The module shall also control two Style Y (Class B) circuits or one Style Z (Class A) circuit. The module shall synchronize multiple zones. Daisy-chaining two or more synchroniza- tion modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature:32°F to 120°F (0°C to 49°C) Humidity Range:10 to 93% non-condensing Strobe Flash Rate:1 flash per second Nominal Voltage:Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2:8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) Sync Module:8.5 to 17 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge:12 to 18 AWG Wall-Mount Dimensions (including lens):5.6 L × 4.7 W × 1.25 D (143 mm L×119 mm W × 32 mm D) Compact Wall-Mount Dimensions: (including lens) 5.26” L x 3.46” W x 1.93” D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions:5.6 L × 4.7 W × 1.25 D (143 mm L×119 mm W × 32 mm D) Compact Horn Dimensions:5.25” L x 3.45” W x 1.25” D (133mm L x 88mm W x 32mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 cd and 30 cd. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118www.gamewell-fci.com 9021-60929 Rev. A page 3 of 4 UL Current Draw Table 1 lists the UL maximum Strobe current draw. Table 2 lists the UL maximum Horn current draw. Candela 8-17.5 Volts 16-33 Volts FWRDC DC Candela Range 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 Table 1: UL Maximum Strobe Current Draw (mA RMS) Sound Pattern dB 8-17.5 Volts 16-33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 Table 2: UL Max. Horn Current Draw (mA RMS) UL Current Draw Data Table 3 lists the maximum UL Current Draw (mA RMS) allowed for 2-Wire Horn Strobes, candala range (15-115cd). Horn Strobe Tones and Sound Output Data Table 4 lists the horn strobe tones and sound output data. DC Input 8-17.5 Volts 16-33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd EM Temp Hi 98 158 54 74 121 142 162 196 245 EM Temp Low 93 154 44 65 111 133 157 184 235 EM Cont Hi 106 166 73 94 139 160 182 211 262 EM Cont Low 93 156 51 71 119 139 162 190 239 3.1K Temp Hi 93 156 53 73 119 140 164 190 242 3.1K Temp Low 91 154 45 66 112 133 160 185 235 3.1K Cont Hi 99 162 69 90 135 157 175 208 261 3.1k Cont Low 93 156 52 72 119 138 162 192 242 16V FWR FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd EM Temp Hi 83 107 156 177 198 234 287 EM Temp Low 68 91 145 165 185 223 271 EM Cont Hi 111 135 185 207 230 264 316 EM Cont Low 79 104 157 175 197 235 283 3.1K Temp Hi 81 105 155 177 196 234 284 3.1K Temp Low 68 90 145 166 186 222 276 3.1K Cont Hi 104 131 177 204 230 264 326 3.1k Cont Low 77 102 156 177 199 234 291 Table 3: UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Candela Range (15–115 cd) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts F W R DC DC 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9 Coded High 85 90 90 10 3.1 KHz Coded High 84 89 89 Table 4: Horn Strobe Tones and Sound Output Data GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118page 4 of 4 www.gamewell-fci.com 9021-60929 Rev. A L Series Dimensions Figure 1 Compact Combo L Series Dimensions Figure 3 Standard Combo L-Series Ordering Information Wall Horn Strobes Part Number Description P2RL 2-Wire, Standard Horn Strobe, Red P2WL 2-Wire, Standard Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Compact Horn Strobe, White P2RL-P 2-Wire, Standard Horn Strobe,Red, Plain P2WL-P 2-Wire,Standard Horn Strobe,White,Plain P2RL-SP 2-Wire,Standard Horn Strobe,Red, FUEGO P2WL-SP 2-Wire, Standard Horn Strobe, White, FUEGO Wall Strobes SRL Standard Strobe, Red SWL Standard Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Standard Strobe, Red, Plain SWL-P Standard Strobe, White, Plain SRL-SP Standard Strobe, Red, FUEGO SWL-CLR-ALERTStandard Strobe, White, ALERT L Series Dimensions Figure 2 Compact Horn L Series Dimensions Figure 4 Standard Horn L-Series Ordering Information Horns Part Number Description HRL Standard Horn, Red HWL Standard Horn, White HGRL Compact Horn, Red HGWL Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Standard Wall Surface Mount Backbox, Red SBBWL Standard Wall Surface Mount Backbox, White SBBGRL Compact Wall Surface Mount Backbox, Red SBBGWL Compact Wall Surface Mount Backbox, White Notes: All -P models have a plain housing (no “FIRE” marking on cover). All -SP models have “FUEGO” marking on cover. All -ALERT models have “ALERT” marking on cover. Agency Listings Features • 520 Hz ± 10% square wave tone • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Field-selectable candela settings on wall units: 135, 150, 177, and 185 • Rotary switch for low frequency sounder tone • Universal mounting plate for wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with legacy SpectrAlert devices • Compatible with MDL3 sync module • Listed for ceiling or wall mounting The SpectrAlert Advance series offers the most versatile and easy-to-use line of low frequency sounder and low frequency sounder strobes in the industry. With white and red plastic housings, dual listed for wall and ceiling mounting, SpectrAlert Advance can meet virtually any application requirement. The wall-mount low frequency sounder, and low frequency sounder strobes were designed to address the NFPA 72 sleeping space requirements that require a low frequency notification appliance that operates within frequency range of 520 Hz ± 10% and is of a square wave tone. Like the entire SpectrAlert Advance product line they include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for 520 Hz low frequency sounder tones. Selectable-Output Low Frequency Sounder and Low Frequency Sounder Strobes for Wall Applications SpectrAlert® Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. 3047563 7135-1653:02237125-1653:0224 S4011 (sounder)S5512 (strobes)MEA452-05-E SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance low frequency sounder and low frequency sounder strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Low Frequency Sounder strobes shall have field-selectable candela settings including 135, 150, 177, and 185. The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone and have a permanent marking on the housing that reads “low frequency sounder”. Low Frequency Sounder The low frequency sounder shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 464 and shall be approved for fire protective service. The low frequency sounder and the Sync•Circuit™ MDL3 Module accessory, if used, shall be powered from a notification appliance circuit output and shall operate on a nominal 12 or 24 volts (includes fire alarm panels with built in sync). When used with the Sync•Circuit Module MDL3, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts. If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used, then refer to the compatibility listing of the panel to determine maximum devices on a circuit. The low frequency sounder has an option to switch between temporal three pattern, non-temporal (continuous) pattern and coded supply within the frequency range of 520Hz ± 10% square wave tone. The low frequency sounder shall operate on a coded or non-coded power supply. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The sounder shall have an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply. The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three. Also, while operating the strobes, the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires. The module shall mount to a 411⁄16 × 411⁄16 × 21⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Frequency Range 520 Hz ± 10% Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 12 DC/FWR or regulated 24 DC/FWR1 Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens)6.4 inches L x 4.7 inches W x 2.5 inches D (162 mm L x 119 mm W x 64 mm D) Sounder Dimensions 5.6 inches L × 4.7 inches W × 1.3 inches D (142 mm L × 119 mm W × 33 mm D) Low Frequency Sounder/Strobe with Surface Mount Back Box Dimensions (SBBR, SBBW) 6.4 inches L x 4.7 inches W x 4.3 inches D (162 mm L x 120 mm W x 108 mm D) Low Frequency Sounder with Surface Mount Back Box Dimensions (SBBR, SBBW) 5.7 inches L x 4.8 inches W x 3 inches D (145 mm L x 120 mm W x 76 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. Low Frequency Sounder and Low Frequency Sounder Strobe Output (dBA) Switch Position Sound Pattern 8–17.5 Volts 16–33 Volts 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal 3 76 76 76 76 76 76 86 86 2 Continuous 80 80 80 80 80 80 90 90 3†Coded 80 80 80 80 80 80 90 90 UL Max. Low Frequency Sounder Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC FWR DC FWR Temporal 3 High 191 262 138 166 Continuous High 292 384 138 208 Coded High 292 388 153 205 UL Max. Current Draw (mA RMS), 2-Wire Low Frequency Sounder Strobe, High Candela Range DC Input 16–33 Volts FWR Input 16–33 Volts 135 150 177 185 135 150 177 185 Temporal 3 277 292 325 344 Temporal 3 296 309 343 351 Continuous 337 362 387 417 Continuous 393 395 432 433 UL Current Draw Data Low Frequency Sounder Tones and Sound Output Data † Sounder ratings provided are for continuous voltage as provided by the NAC 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2015 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS16404 • 1/15 SpectrAlert Advance Dimensions Model Description Wall Low Frequency Sounder Strobes P2RH-LF 2-Wire Low Frequency Sounder Strobe, High cd, Red P2WH-LF 2-Wire Low Frequency Sounder Strobe, High cd, White Low Frequency Sounders HR-LF Low Frequency Sounder, Red HW-LF Low Frequency Sounder, White Accessories SBBR Surface Mount Back Box, Wall, Red SBBW Surface Mount Back Box, Wall, White TR-HS Trim Ring, Wall, Red SpectrAlert Advance Ordering Information Notes: “High cd” refers to strobes that include 135, 150, 177, and 185 candela settings. 4.7 in. 6.4 in. 2.5 in. 4.7 in. 5.6 in. 1.3 in. Wall-mount low frequency sounder strobes Wall-mount low frequency sounder Worry-Free AC Wire-in Combination Smoke & Carbon Monoxide (CO) Alarm Sealed Lithium Battery Backup Model i12010SCO Description The Kidde i12010SCO is a hardwired combination smoke and carbon monoxide alarm that contains a 10-year, sealed battery backup. This alarm uses breakthrough technology to offer a fast response to real fires, including smoldering and fast-flaming, as well as protect you from carbon monoxide and dramatically reduce the chance of nuisance alarms. The Intelligent sensor tech- nology combines the detection capabilities of an ionization smoke sensor – which is more likely to detect smaller, less visible fire particles, like those produced by flaming fires – with that of an electrochemical sensor, which is used to detect CO. Since carbon monoxide is present in all fires, having both detection chambers work together in one alarm is a breakthrough in the fire safety industry. When either sensor notices a potential hazard, it will communicate with the other. Depending on what is detected, the alarm will adjust its smoke sensitivity in order to better discrimi- nate between a real hazard and a false one. This constant com- munication enhances the alarm’s overall performance in all fires, and significantly reduces the potential for a nuisance alarm. Leading authorities recommend that both ionization and photo- electric smoke alarms be installed to help insure maximum detec- tion of the various types of fires that can occur within the home. Ionization sensing alarms may detect invisible fire particles (associ- ated with fast flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible fire particles (asso- ciated with slow smoldering fires) sooner than ionization alarms. The i12010SCO contains a 10-year tamper proof backup battery that eliminates the need for battery replacement, and ends worry over unauthorized battery removal. The alarm provides continuous protection from smoke, fire and carbon monoxide, even during power outages. At the end of alarm life, the unit will chirp, indi- cating the alarm is in need of replacement. The end of life chirp can be temporarily silenced, allowing for replacement at a more convenient time. Features and Benefits • Sealed-In Lithium Battery Backup – no battery replacement required over the 10 year life of the alarm. Eliminates worry about removal or unauthorized deactivation of alarm. • Voice Warning System – Verbally announces “FIRE!” or “WARNING! CARBON MONOXIDE” to help distinguish between threats. • Smart Interconnect – Interconnects up to 24 Kidde devices (of which 18 can be initiating) • Hush Feature – Temporarily silences nuisance alarms for approximately 9 minutes and will not allow hush mode unless the unit is in alarm mode. • Peak Level Memory – Announces “CARBON MONOXIDE PREVIOUSLY DETECTED” if alarm has detected CO level of 100ppm or higher since it was last reset. • Ionization Sensing Technology – Ideal for detecting fast flaming and other types of fires. • Green LED – Illuminates to indicate the unit is receiving AC power. Flashes once every 60 seconds to indicate battery only mode. Flashes once per second during alarm to indicate initiating alarm. Flashes once every 16 seconds to indicate smoke or CO previously detected. Flashes every 2 seconds while the alarm is in HUSH mode. • Red LED – When a dangerous level of smoke or carbon monox- ide is detected the red LED will flash. If the unit malfunctions, the red LED will flash and the unit will chrip every 30 seconds.. Sealed 3V Lithium Battery Backup 10-year* tamper proof battery eliminates need for battery replacement. Alerts user to replace alarm after 10 years of operation. Voice Warning Warns of hazard by announcing “Fire!” or “Warning, Carbon Monoxide.” Intelligent Sensor Technology Reduces nuisance alarms and offers fast response to real fires. Test/Hush Button Functions A single button that tests alarm circuitry and temporarily silences nuisance alarms. Two LED Display Red LED indicates alarm mode, Green LED indicates AC power is present Peak Level Memory Alerts user when the unit has detected CO concentrations of 100ppm or higher. 10 * Worry-Free 120V AC Wire-in Combination Smoke & Carbon Monoxide Alarm Sealed Lithium Battery Backup Model i12010SCO Architectural and Engineering Specifications The combination smoke and carbon monoxide alarm shall be Kidde model i12010SCO or approved equal. It shall be powered by 120VAC, 60Hz source with on 3V sealed lithium battery backup. The temperature operating range shall be between 40˚F and 100˚F (4˚C and 38˚C) and the humidity operating range shall be 10% - 95% relative humidity, non-condensing. The unit shall incorporate an ionization smoke sensor with nominal sensitivity of 0.50-1.22%/ft. The CO sensor shall be of a fuel cell design and shall meet the sensi- tivity requirements of Underwriters Laboratories UL2034 Single and Multiple Station Carbon Monoxide Detectors. The combination alarm can be installed on the surface of any wall or ceiling follow- ing the UL/NFPA/Manufacturer’s recommended placement guidelines. The alarm can be installed on any standard single gang electrical box, up to a 4” octagon junction box. The electrical connection (to the alarm) shall be made with a plug-in connector. The unit shall provide optional tamper resistance that deters removal of the unit from the wall or ceiling. No additional pieces shall be required to activate this feature. A maximum of 24 Kidde devices can be interconnected in a multiple station arrangement. The interconnect system must not exceed the NFPA (National Fire Protection Association) limit of 18 initiating devices, of which 12 can be smoke alarms. With 18 initiating devices (smoke, heat, CO, etc), interconnected, it is still possible to interconnect 6 strobe lights and or relay modules. The alarm shall include a test button that will electronically simulate the presence of smoke and CO and cause the unit to go into both modes of alarm. This sequence tests the unit’s electronics to ensure proper operation. The CO sensor will not alarm to levels of CO below 30 ppm and will alarm in the following time range when exposed to the corresponding levels of CO. 70 ppm CO Concentration 60 – 240 minutes 150 ppm CO Concentration 10 – 50 minutes 400 ppm CO Concentration 4 – 15 minutes The combination alarm shall have two methods of warning for danger: a piezoelec- tric horn that is rated at 85 decibels at 10 feet and a voice warning that identifies the danger. For a CO incident, the horn will sound in the repetitive manner – four (4) fast beeps, a short pause, four (4) fast beeps, a short pause. In between, the unit will announce “Warning Carbon Monoxide!” In a Smoke incident, the horn will sound in the repetitive manner – three (3) beeps, a pause, three (3) beeps, a pause. In between, the unit will announce “Fire!” The unit shall incorporate 2 LED’s. A green LED will be steady on when AC power is present, flash every 60 seconds when in the battery only mode, every second to indicate alarm memory, and every 2 seconds to indicate the Hush“ mode is active. A red LED will flash in unison with the sounder pattern. The unit shall include the HushTM feature that silences the unit for approximately 9 minutes if a nuisance alarm condition occurs. The Green LED on the alarm will flash every 2 seconds while in HushTM and will automatically reset itself. It also provides voice annunciation of “Hush Mode Activated” when HushTM is activated and “Hush Mode Cancelled” when the Hush cycle ends. The unit shall also indicate a low battery warning utilizing each of the following methods: a brief alarm chirp, the voice announcement of “Low Battery!” The unit shall at a minimum meet the requirements of UL 2034, UL217, NFPA72, (chapter 11 2002 edition) The State of California Fire Marshall, NFPA101 (One and two family dwellings) Federal Housing Authority (FHA), Housing and Urban Development (HUD). It shall also include a 10-year manufacturer’s limited warranty. Ordering Information Installation of Smoke Alarm The combination alarm should be installed to comply with all local codes having jurisdiction in your area, Article 760 of the National Electric Code, and NFPA 72. Make certain all alarms are wired to a single, continuous (non-switched) power line, which is not protected by a ground fault interrupter. A maximum of 1000 ft. of wire can be used in the intercon- nect system. Use standard UL listed household wire (18 gauge or larger as required by local codes). FUSE OR CIRCUIT BREAKER BLACK WHITE RED LN First Alarm Additional Alarms KL-i-AC/DCCombo sheet rev. 02-2014 Distributed by: Ordering Pack Pack Dimensions Cartons/Number UPC I2F5 Config. Quantity (w x d x h inches) Weight Pallet 21010408 0-47871-10408-6 100-47871-10408-3 BOX Master Pack (6 Units) 6.0 x 13.0 x 6.0 2.7 126 Not for sale by individual unit Technical Specifications Power Source: 120VAC, 60Hz 45mA max per alarm Saled lithium battery backup Smoke Sensor: Ionization CO Sensor: Electrochemical Audio Alarm: 85dB at 10ft Temperature Range: 40˚F (4.4˚C) to 100˚F (37.8˚C) Humidity Range: 10%-95% relative humidity, non-condensing Size: 5.5” in diameter x 1.75” depth Weight: 1lb Wiring: Quick connect plug with 6” pigtails Interconnects: Up to 24 Kidde devices (of which 18 can be initiating) Warranty: Ten year limited 5.5”1.75” 1016 Corporate Park Drive Mebane NC 27302 1-800-880-6788 www.Kidde.com Worry-Free 120V AC Wire-in Smoke Alarm Sealed Lithium Battery Backup Model i12010S Description The Kidde i12010S is an AC/DC powered, ionization smoke alarm that operates on a 120V power source with sealed-in lithium battery backup. This alarm uses ionization sensing technology. Ionization sensing alarms may detect invisible fire particles (associated with flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible particles (associated with smoldering fires) sooner than ionization alarms. Leading authorities recommend that both ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various types of fires that can occur within the home. The i12010S contains a 10-year tamper proof battery that eliminates the need for battery replacement, and ends worry over unauthorized battery removal. The alarm provides continuous protection from smoke and fire, even during power outages. At the end of alarm life, the unit will chirp, indicating the alarm is in need of replacement. The customer can use a simple tool such as a screwdriver to deactivate the unit, stopping the chirp and making it safe for disposal. The end of life signal can be temporarily silenced to allow for replacement at a more convenient time. Install Confidence: Easy Installation • Battery backup automatically activates when the alarm is attached to mounting bracket • Large mounting base makes mounting easier, protects surface paint from dirt and covers imperfections. • Pre-stripped wiring harness with easy off cap does not require stripper tool. Tinned strands increase conductivity and wire nut grip. Fewer Callbacks • 10-year sealed battery substitutes need for routine 9V replacement • Large centrally located Test/Hush® alarm control button silences nuisance alarms for approximately 9 minutes. • Dust cover protects sensor from contaminates during construction, reducing nuisance alarms. User-Friendly Features • Red LED indicates alarm mode, Green LED indicates AC power is present. • Interconnectable with up to 24 devices (of which 18 can be initiating) including smoke, CO and heat alarms. See user guide for complete instructions. • End of Life Hush feature allows user to temporarily silence end of life chirp 3 days at a time for a maximum of 30 day life extension. — Ionization Sensing Technology — Sealed-In 10-Year* Lithium Battery Backup — Hush® Button — Alarm Memory Indicator — 360° Mounting Plate with Tamper Resistance — 2 LED Indicators 10 * Architectural and Engineering Specifications The smoke alarm shall be Kidde Model i12010S or approved equal. It shall be powered by a 120VAC, 60Hz source along with a 3V sealed lithium battery backup. The unit shall incorporate an ionization sensor with nominal sensitivity of 0.50 to 1.04%/ ft. The temperature operating range shall be between 40°and 100°F (4°C and 38°C) and the humidity operating range shall be up 95% relative humidity, non-condensing. The smoke alarm can be installed on any standard single gang electrical box, up to a 4” octagon junction box. The electrical connection (to the alarm) shall be made with a plug-in connec- tor. A maximum of 24 Kidde devices can be interconnected in a multiple station arrangement. The interconnect system must not exceed the NFPA (National Fire Protection Association) limit of 18 initiating devices, of which 12 can be smoke alarms. With 18 initiating devices (Smoke, heat, CO, etc), interconnected, it is still possible to interconnect 6 strobe lights and/or relay modules. The alarm shall provide optional tamper resistance that deters removal of the unit from the wall or ceiling. No additional pieces shall be required to activate this feature. The alarm shall include a test button that will electronically simu- late the presence of smoke and cause the unit to go into alarm. This sequence tests the unit’s electronics, battery and horn to ensure proper operation. The unit shall include a piezoelectric horn that is rated at 85 decibels at 10 feet. The unit shall include the Smart Hush™ feature that silences the unit for approximately 9 minutes if a nuisance condition occurs. The unit shall indicate a low battery condition with a brief alarm chirp and red LED flash once every 60 seconds. In standby con- dition, the green LED will be constantly on when powered by AC, and flash every 60 seconds when powered by only battery backup. The green LED will also flash every 2 seconds when in Hush mode, and every 16 seconds in Memory Condition. The smoke alarm shall include an End of Life Alert, where ten years after initial power-up the unit shall chirp two times every 30 seconds to indicate the alarm needs to be replaced. The End of Life signal can be silenced three days at a time for a maxi- mum of 30 days. The unit shall have a deactivation switch to disable it and make it safe for disposal. The unit shall at a minimum meet the requirements of UL217, NFPA72, and (chapter 11), The State of California Fire Marshall, NFPA101 (0ne and two family dwellings), Federal Housing Authority (FHA), Housing and Urban Development (HUD). It shall also include a 10-year manufacturer’s limited warranty. FUSE OR CIRCUIT BREAKER BLACK WHITE RED LN First Alarm Additional Alarms Worry-Free 120V AC Wire-In Smoke Alarm Sealed Lithium Battery Backup Model i12010S Technical Specifications Model: i12010S Power Source: 120VAC (60 Hz, 45mA Max) Sensor: Ionization Audio Alarm: 85dB at 10ft Temperature Range: 40˚F (4.4˚C) to 100˚F (37.8˚C) Humidity Range: Up to 95% relative humidity (RH), non-condensing Size: 5.5” in diameter x 1.75” depth Weight: .45lbs Interconnects: Up to 24 Kidde devices Warranty: 10 year limited Installation of Smoke Alarm The smoke alarm should be installed to comply with all local codes having jurisdic- tion in your area, Article 760 of the National Electric Code, and NFPA 72. Make certain all alarms are wired to a single, continuous (non-switched) power line, which is not protected by a ground fault interrupter. A maximum of 1000 ft. of wire can be used in the interconnect system. Use standard UL listed household wire as required by code. 1016 Corporate Park Drive Mebane NC 27302 1-800-880-6788 www.Kidde.com Distributed by: P/N: KL-i12010S-sheet rev. 08-2014 Ordering Information Ordering Pack Pack Dimensions Cartons/Number UPC I2F5 Config. Quantity (w x d x h inches) Weight Pallet 21010407-A 0-47871-11407-8 100-47871-11407-5 BOX Master Pack (6 Units) 6.0 x 13.0 x 6.0 2.7 126 Not for sale by individual unit 5.5”1.75” • HP300ULX • HP300ULM • HP300ULPD4CB Power Limited Supplies/Chargers HP300ULX h1024300ulx.jpgDescription The HP300UL Series is a line of power limited supplies/charg- ers that will convert 115 VAC/60 Hz input into a power limited 12VDC or 24 VDC output @ 2.5 A. They are used in applications requiring UL Listing for Access Control (UL294), Fire Alarm(UL1481), and Burglar Alarm Installations (UL603). • HP300ULX - Includes the supply, enclosure, transformer and battery leads. • HP300ULM - Includes the supply, HPMOM6 multi-outputpower distribution module, enclosure, transformer and bat- tery leads. • HP300ULPD4CB - Includes the supply, a four-output individ- ually protected power distribution board (with auto-resettablePTC circuit breakers), enclosure, transformer and battery leads. Benefits • An all in one power supply and distribution unit enclosed in roomy cabinet. • Transformer thermal protection limits damage from over- loaded circuits. • LED lights for quick and easy diagnosis, troubleshooting, and status indication. • Comes fully assembled with accessories included for quick installation. • Enclosure built for durability and product life. • Power disconnect switch makes for easy servicing. • Power cord included and has three conductors for ground safety convenience. • Instantaneous switchover to standby battery (if equipped) when AC fails, maintaining power to all attached deviceswithout intervention. Specifications • UL294 for use with Access Control Systems. • UL1481 for use with Fire Alarm Systems. • UL603 for use with Burglar Alarm Installations. • Switch selectable 12 VDC or 24 VDC power limited output. • Input: 115 VAC /60 Hz, 0.9A. • 2.5 A continuous supply current at 12 VDC or 24 VDC. • Filtered and electronically regulated outputs. • Built-in charger for sealed lead acid or gel type batteries. Charge current 600mA. • Automatic switch-over to standby battery when AC fails. • AC input and DC output LED indicators. • AC fail supervision (Form "C" contacts). • Low battery supervision (Form "C" contacts). • Low battery disconnect prevents batteries from deep dis- charge. • Thermal overload protection. • Short circuit protection. • Includes battery leads. • Enclosure Dimensions: 13"H x 13.5"W x 3.25"D (cm: 33.02Hx 34.29W x 8.26D). Accommodates up to two (2) 12AH batteries. HPMOM6 Specifications • NFPA 72 compliant. • Class 2 outputs. • 12 VDC or 24 VDC operation. • Six (6) individual power-limited outputs. Current limit is 2.5 A @ 12 VDC or 24 VDC per output. • Fire Alarm Panel or Access Control System inputs (NO or NC supervised trigger input and polarity reversal trigger input). • Red LEDs indicate condition of each power output. • Power and input trigger LEDs. • Power fail supervision relay (Form "C" rates 1.0 A @ 28 VDC/ 115 VAC). • Output relay indicates unit is triggered (Form "C" rated 1.0 A @ 28 VDC/115 VAC). • Interfaces with most DC power supplies. • Board Dimensions: 5.3"L x 3.5"W x 1"H (cm: 13.46L x 8.89Wx 2.54H). Distribution Board Specifications • Distributes power rated up to 28 VAC/VDC • power disconnect switch. • Uses automotive-style fuses (rated 3.0 A) to individually pro-tect each circuit . • LED indicator lights. • Mounts with included foam backed adhesive tape or optional HST34 snap track. • Compact design. • Temperature range: 32°F to 120°F (0°C to 49°C). • Board dimensions: 3.0" H x 4.3" W x 1.0" D (cm: 7.62 H x 10.922 W x 2.54 D) Agency Listings and Approvals Listings and approvals below apply to the HP300UL Series. In some cases, certain modules may not be listed by certainapproval agencies, or listing may be in process. Consult factory for latest listing status. • Listed to Standards UL 294 (Access Control System Units), UL 603 (Power Supplies for use with Burglar-Alarm Sys-tems), and UL 1481 (Power Supplies for Fire-Protective Sig- naling Systems). •UL Listed: S6677 •CSFM: 7300-1637:101 •MEA: 114-07-E (correction) This unit has not been evaluated as elevator equipment, anD is not authorized for bell output in Mercantile applications. Automation and Control Solutions Honeywell 12 Clintonville Road 1(877) HPP-POWR Northford, CT 06472-1610 hpp_techserv@honeywell.com www.honeywellpower.com This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. ©2007 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. DH-1024:ADecember 2007Made in the U.S.A.® U.S. Registered Trademark© 2007 Honeywell International Inc.Page 2 of 2 h1024sys3ULX.tifh1024sys3ULM.tifh1024sys3ULP4.tifHP300ULX HP300ULM HP300ULPD4CB Agency Listings 7135-1653:0503 S4011 3057383, 3057072 Features • Updated modern aesthetics • Plug-in design with minimal intrusion into the back box • Mounting plate shorting spring feature checks wiring continuity before device installation • Captive mounting screw • Tamper-resistant construction • Field-selectable candela settings: – Wall: 15, 30, 75, 95, 110, 135, 185 – Ceiling: 15, 30, 75, 95, 115, 150, 177 • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Rotary switch for tone and volume selections • Five selectable tones with high and low volume settings • Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices • Wall models listed for wall mounting only, ceiling models listed for ceiling mounting only The System Sensor L-Series product line of wall and ceiling- mount chimes and chime strobes include a variety of features that increase their application versatility while simplifying the installation. With white and red plastic housings, System Sensor L-Series can meet virtually any application requirement. Selectable-output chimes and chime/strobes are private mode notification appliances used to alert trained personnel to investigate possible emergency situations and to take appropriate action. Security guard and nurse workstations are ideal locations for chime products. All devices feature plug-in design with minimal intrusion into the back box, making the installation fast and foolproof while virtually eliminating costly and time-consuming ground faults. Installers can easily adapt devices to a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or-24 volt operation, and a rotary switch for chime tones and two volume selections. Selectable Output Chimes and Chime/Strobes System Sensor L-Series selectable-output chimes and chime/strobes are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. AVDS86902 • 11/02/2017 • Page 1 L-Series Specifications Architect/Engineer Specifications General System Sensor L-Series chimes and chime strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box, single- gang 2 × 4 × 17/8-inch back box, or double-gang back box. A universal mounting plate shall be used for mounting products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, System Sensor L-Series products, when used with the Sync•Circuit Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. Chime strobes shall have field-selectable candela settings of 15, 30, 75, 95, 110 , 135, and 185 for wall units and 15, 30, 75, 95, 115, 150, and 177 for ceiling units. Chime Strobe Combination The chime strobe shall be a System Sensor L-Series Model _______ listed to UL 1638 and UL 464. The chime strobe shall comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The chime shall have two audibility options and an option to switch between temporal three pattern, non-temporal(continuous) pattern, 1 second chime pattern, 1/4 second chime pattern, 5 second whoop chime pattern. These options are set by a multiple position switch. Synchronization Module The module shall be a System Sensor Sync•Circuit _______ listed to UL 464 and shall be approved for fire protective service. The module shall synchronize strobes at 1Hz and all available chime tones. Also, while operating the strobes, the module shall silence the chimes on chime/strobe models over a single pair of wires. The module shall mount to a 4 11/16 × 4 11/16 × 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12VDC or regulated 24DC/FWR1 Operating Voltage Range2 8 to 17.5V (12V nominal) or 16 to 33V (24V nominal) Operating Voltage Range with MLD3 8.5 to 17.5V (12V nominal) or 16.5 to 33V (24V nominal) Input terminal wire gauge 12 to 18 AWG Chime strobe dimensions (including lens)5.6 in L × 4.7 in W × 1.91 in D (143 mm L × 119 mm W × 49 mm D) Chime dimensions 5.6 in L × 4.7 in W × 1.25 in D (143 mm L × 119 mm W × 32 mm D) Ceiling Chime strobe dimensions (including lens)6.8” Dia. x 2.47” D (173.5mm Dia. x 62.7mm D) SBBRL (red wall surface mount back box)5.6 in L × 4.7 in W × 4.3 in D (142 mm L × 119 mm W × 109 mm D) SBBWL (white wall surface mount back box)5.6 in L × 4.7 in W × 4.3 in D (142 mm L × 119 mm W × 109 mm D) SBBCRL (red ceiling surface mount back box)6.9” Dia. x 2.5” D (175.8mm Dia. x 63.5mm) SBBCWL (white ceiling surface mount back box)6.9” Dia. x 2.5” D (175.8mm Dia. x 63.5mm) Notes: 1. Full Wave Rectified (FWR) voltage is a non-filtered, time varying power source that is used on some power supply and panel outputs. 2. CHS products will operate at 12 V nominal only for 15 and 30 cd. UL Max. Chime Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Second Chime High 5 8 9 1 Second Chime Low 5 8 9 1/4 Second Chime High 6 10 10 1/4 Second Chime Low 5 9 9 Temporal Chime High 7 10 10 Temporal Chime Low 6 9 9 5 Second Whoop High 12 15 16 5 Second Whoop Low 7 10 11 Coded High 12 15 16 * UL Current Draw Data *This data represents coding at 3 chimes per second. Actual current draw will vary depending upon coding selected. AVDS86902 • 11/02/2017 • Page 2 Chime Patterns Setting Repetition Rate dB Level 1 1 Second Chime High 2 1 Second Chime Low 3 1/4 Second Chime High 4 1/4 Second Chime Low 5 Temporal Chime High 6 Temporal Chime Low 7 5 Second Whoop High 8 5 Second Whoop Low 9 Coded**High **For chime only. Chime and Chime/Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 1 Second Chime High 61 62 62 2 1 Second Chime Low 56 55 55 3 1/4 Second Chime High 67 70 70 4 1/4 Second Chime Low 61 61 61 5 Temporal Chime High 64 66 66 6 Temporal Chime Low 59 60 60 7 5 Second Whoop High 76 78 78 8 5 Second Whoop Low 62 64 64 9 Coded**High 57 51 57 Tone Selection Chime tone selection is accomplished by using the rotary switch on the back of the product. The current draw and sound measurements for various chime tone settings are listed below. UL Max. Chime/Strobe Current Draw (mA RMS) Wall DC Input 8–17.5 Volts 16–33 Volts 15 30 15 30 75 95 110 135 185 1 Second Chime 90 154 51 71 115 136 161 202 238 1 Second Chime 89 154 50 70 116 136 154 199 242 1/4 Second Chime 90 154 52 72 117 137 168 201 242 1/4 Second Chime 89 153 49 70 115 136 165 199 241 Temporal Chime 88 153 49 69 112 137 168 201 246 Temporal Chime 88 152 47 68 111 136 167 196 241 5 Second Whoop 91 154 52 70 113 132 176 206 243 5 Second Whoop 87 149 46 66 108 130 170 202 240 FWR Input 16–33 Volts 15 30 75 95 110 135 185 1 Second Chime 70 90 160 176 197 233 275 1 Second Chime 67 88 158 175 191 232 271 1/4 Second Chime 69 93 159 175 198 233 272 1/4 Second Chime 68 93 154 169 196 232 270 Temporal Chime 65 90 145 170 189 228 283 Temporal Chime 64 89 142 170 188 219 282 5 Second Whoop 70 93 145 168 187 223 278 5 Second Whoop 62 84 137 159 180 216 272 UL Max. Chime/Strobe Current Draw (mA RMS) Ceiling DC Input 8–17.5 Volts 16–33 Volts 15 30 15 30 75 95 115 150 177 1 Second Chime 95.5 165 47 69 117 137 165 202 238 1 Second Chime 93 162 47 68 116 137 165 200 238 1/4 Second Chime 94 161 48 70 117 138 166 202 237 1/4 Second Chime 93 157 48 69 116 137 164 199 236 Temporal Chime 93 163 48 69.5 116 138 165 199 238 Temporal Chime 92 160 47 68.5 116 136 164 198 237 5 Second Whoop 98 169 54 77 124 146 173 206 245 5 Second Whoop 95 166 49 71 117 144 168 202 239 FWR Input 16–33 Volts 15 30 75 95 115 150 177 1 Second Chime 63 90 147 169 184 212 245 1 Second Chime 63 88 147 169 183 212 244 1/4 Second Chime 65 90 149 170 184 213 246 1/4 Second Chime 64 89 148 168 184 213 244 Temporal Chime 64 89 148 169 184 212 245 Temporal Chime 63 88 147 169 183 212 245 5 Second Whoop 75 100 155 178 193 221 255 5 Second Whoop 68 91 148 170 186 217 248 AVDS86902 • 11/02/2017 • Page 3 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS86902 • 11/02/2017 L-Series Dimensions Model Description CHRL Chime, Wall, Red CHWL Chime, Wall, White CHSRL Chime Strobe, Wall, Red CHSWL Chime Strobe, Wall, White CHSCRL Chime Strobe, Ceiling, Red CHSCWL Chime Strobe, Ceiling, White Accessories SBBRL Surface Mount Back Box, Wall, Red SBBWL Surface Mount Back Box, Wall, White SBBCRL Surface Mount Back Box, Ceiling, Red SBBCWL Surface Mount Back Box, Ceiling, White L-Series Ordering Information Wall Chime CHRL, CHWL Ceiling Mount Chime/Strobe with Ceiling Surface Mount Back Box Wall Chime/Strobe CHSRL, CHSWL Wall Mount Chime/Strobe with Wall Surface Mount Back Box 4.7"119 mm 1.91"48.5 mm 1.25"32 mm 5.67"144 mm 4.70" (11.94 cm) 5.67" (14.4 cm) 1.25" (3.18 cm) Wall Surface Mount Back Box SBBRL/SBBWL A0554-01 4.82" (12.24 cm)1.85" (4.69 cm) 5.78" (14.68 cm) Ceiling Chime/Strobe CHSCRL, CHSCWL Ceiling Surface Mount Back Box SBBCRL, SBBCWL 6.92" dia. (175.77 mm) 2.5" (64 mm)6.8" dia. 173 mm 2.47" 62.7 mm 1.37" 34.8 mm A0546-00A0545-00 A0490-01A0494-00 A0554-01A0550-01A0549-00 TO NEXT DEVICEOR EOL RESISTORAT LAST DEVICEFROM PREVIOUSDEVICE OR SNAC-9SPECTRALERT ADVANCED++-P2RHORN/STROBESPECTRALERT ADVANCED++-SRHORN/STROBESPECTRALERT ADVANCED++-P2RHORN/STROBETYPICAL NOTIFICATION APPLIANCE CIRCUIT WIRING4312+-ADDRESSABLE SWITCHESLOCATED INSIDE COVER OFUNITPOS (+)NEG (-)SLC INITIATING CIRCUIT TO NEXTDEVICE OR RETURN TOORIGINATING DEVICE2 #16AWG2 #16AWGSLC INITIATING CIRCUIT FROMCLOSEST EXISTINGINITIATING DEVICEPOS (+)NEG (-)TYPICAL ADDRESSABLE PULL STATIONM/N MS-7AFSLC INITIATING CIRCUIT FROMCLOSEST EXISTINGINITIATING DEVICEPOS (+)NEG (-)2 #16AWGPOS (+)NEG (-)SLC INITIATING CIRCUIT TO NEXTDEVICE OR RETURN TO ORIGINATINGDEVICE TO MAINTAIN CIRCUITSUPERVISION2 #16AWGTYPICAL ADDRESSABLE SMOKE DETECTORAND HEAT DETECTORB210LP DETECTOR BASE USED WITH ASD-PL2F SMOKE AND ATD-L2F HEAT DETECTOR HEADS1 # 12 AWG3 # 12 AWGANALOG/ADDRESSABLE CONTROL PANELDO NOT USE SHIELDED WIREGW-FCI S3INSTRUMENTSFIRE CONTROLby HoneywellGamewellSSMOKE DETECTORASD-PL3 W/B300-6 BASEABOVE FACP2 #12 AWG (NO SHIELD)SLC CIRCUITEARTHGROUND120VACPOWER FEEDLOCATED IN ELEC 1504 #18 AWG (NO SHIELD)AND 2 # 14 AWG2 # 14 AWGHORN STROBEPSRLENTRY 1492 # 14 AWG2 # 14 AWG2 # 14 AWGSSMOKE DETECTORASD-PL3 W/B300-6 BASEENTRY 149SSMOKE DETECTORASD-PL3 W/B300-6 BASEENTRY 148HHEAT DETECTORATD-L3 W/B300-6 BASELAUNDRY 147HHEAT DETECTORATD-L3 W/B300-6 BASEJANITOR 146SSMOKE DETECTORASD-PL3 W/B300-6 BASEWATER 145SSMOKE DETECTORASD-PL3 W/B300-6 BASERPZ 144SSMOKE DETECTORASD-PL3 W/B300-6 BASEENTRY 143SSMOKE DETECTORASD-PL3 W/B300-6 BASEENTRY 142FADDRESSABLEPULL STATIONMS-7AFSTAIR 02FADDRESSABLEPULL STATIONMS-7AFSTAIR 01SSMOKE DETECTORASD-PL3 W/B300-6 BASETOP OF STAIR 01SSMOKE DETECTORASD-PL3 W/B300-6 BASETOP OF STAIR 0215FF15LOW FREQUENCYHORNHW-LFLIVING ROOMUNIT 104FLFLOW FREQUENCYHORNHW-LFBEDROOMUNIT 104FLFJBJUNCTION BOX FORPOTENTIAL FUTURESTROBEBATHROOMUNIT 104JBJUNCTION BOX FORPOTENTIAL FUTURESTROBEBATHROOMUNIT 103LOW FREQUENCYHORNHW-LFBEDROOMUNIT 103FLFLOW FREQUENCYHORNHW-LFLIVING ROOMUNIT 103FLFEOLHORN STROBEPSRLENTRY 14815FLOW FREQUENCYHORN STROBEP2WH-LFLIVING ROOMUNIT 205177FLFLOW FREQUENCYHORN STROBEP2WH-LFBEDROOMUNIT 205177FLFSTROBESWLBATHROOMUNIT 205HORN STROBEPSRLSTAIR 0215FJBJUNCTION BOX FORPOTENTIAL FUTURESTROBEBATHROOMUNIT 204LOW FREQUENCYHORNHW-LFBEDROOMUNIT 204FLFLOW FREQUENCYHORNHW-LFLIVING ROOMUNIT 204FLFEOLLOW FREQUENCYHORNHW-LFLIVING ROOMUNIT 305FLFLOW FREQUENCYHORNHW-LFBEDROOMUNIT 305FLFJBJUNCTION BOX FORPOTENTIAL FUTURESTROBEBATHROOMUNIT 305JBJUNCTION BOX FORPOTENTIAL FUTURESTROBEBATHROOMUNIT 304LOW FREQUENCYHORNHW-LFBEDROOMUNIT 304FLFLOW FREQUENCYHORNHW-LFLIVING ROOMUNIT 304FLFEOLNAC CIRCUITNAC CIRCUIT2 # 14 AWG2 # 14 AWGNAC CIRCUITNAC CIRCUIT2 # 14 AWG2 # 14 AWGTHIRD FLOOR NAC CIRCUITSEARTH GROUND1 #12AWG120VAC POWER FEED3 #12AWGE120VINSTALL P/N E120V SURGESUPPRESSION ON 120VACPOWER FEEDINSTALL 1 EA. GFCI M/N AMM-2FMODULE IN THIS PANEL FORPANEL SUPERVISIONNO PENETRATIONS INBOTTOM OF CABINET12.25"W X 16.0"H X 3.0"DGFCI NAC 24VDC #5POWER BOOSTER PANELM/N HPF902ULADAE.C. LOCATED IN RPZ 144HORN STROBEPSRLRPZ 14415FLOW FREQUENCYHORNHW-LFLIVING ROOMUNIT 102FLFLOW FREQUENCYHORNHW-LFBEDROOMUNIT 102FLFJBJUNCTION BOX FORPOTENTIAL FUTURESTROBEBATHROOMUNIT 102JBJUNCTION BOX FORPOTENTIAL FUTURESTROBEBATHROOMUNIT 101LOW FREQUENCYHORNHW-LFBEDROOMUNIT 101FLFLOW FREQUENCYHORNHW-LFLIVING ROOMUNIT 101FLFEOLHORN STROBEPSRLENTRY 14215FHORN STROBEPSRLENTRY 14315FF15STROBESRLLAUNDRY 147LOW FREQUENCYHORNHW-LFBEDROOMUNIT 103FLFLOW FREQUENCYHORNHW-LFBEDROOMUNIT 102FLFLOW FREQUENCYHORNHW-LFLIVING ROOMUNIT 203FLFJBJUNCTION BOX FORPOTENTIAL FUTURESTROBEBATHROOMUNIT 203JBJUNCTION BOX FORPOTENTIAL FUTURESTROBEBATHROOMUNIT 203LOW FREQUENCYHORNHW-LFBEDROOMUNIT 203FLFLOW FREQUENCYHORNHW-LFBEDROOMUNIT 203FLFEOLHORN STROBEPSRLSTAIR 0115FJBJUNCTION BOX FORPOTENTIAL FUTURESTROBEBATHROOMUNIT 201LOW FREQUENCYHORNHW-LFBEDROOMUNIT 201FLFLOW FREQUENCYHORNHW-LFLIVING ROOMUNIT 201FLFEOLLOW FREQUENCYHORNHW-LFLIVING ROOMUNIT 202FLFLOW FREQUENCYHORNHW-LFBEDROOMUNIT 202FLFJBJUNCTION BOX FORPOTENTIAL FUTURESTROBEBATHROOMUNIT 202LOW FREQUENCYHORNHW-LFLIVING ROOMUNIT 302FLFLOW FREQUENCYHORNHW-LFBEDROOMUNIT 302FLFJBJUNCTION BOX FORPOTENTIAL FUTURESTROBEBATHROOMUNIT 302JBJUNCTION BOX FORPOTENTIAL FUTURESTROBEBATHROOMUNIT 301LOW FREQUENCYHORNHW-LFBEDROOMUNIT 301FLFLOW FREQUENCYHORNHW-LFLIVING ROOMUNIT 301FLFEOLFCI LCD-SLP ANNUNCIATORSTAIR 02(1) CAT 5 CABLE6 # 18 AWGSTARLINK FIRECELLULAR COMMUNICATOR11 3/4"W x 9 5/8"H x 3 3/8"DFCI LCD-SLP ANNUNCIATORSTAIR 024 #18 AWG (NO SHIELD)AND 2 # 14 AWGGENERAL NOTES;1. SHIELDED CABLE SHALL NOT BE USED ON ANY CIRCUITS AS ITRELATES TO THIS FIRE DETECTION SYSTEM UNLESS OTHERWISE NOTED.2. ALL FIRE ALARM CABLING MUST BE INSTALLED A MINIMUM OF1' FROM ALL OTHER HIGH VOLTAGE, LOW VOLTAGE, & TELECOM CABLINGAND A MINIMUM OF 3' FROM ANY BUILDING LIGHTING BALLASTS.3. A TYPICAL SLC INITIATING CIRCUIT MAY HAVE UP TO 159 SENSORSTYLE DEVICES (SMOKE/HEATS/DUCT DETECTORS) AND 159MODULE STYLE DEVICES (PULL STATIONS, MODULES,CONTROL & INPUT MODULES).4. POLARITY MUST BE OBSERVED ON ALL CIRCUITS.5. E.C. TO ENSURE AUDIO SELECT DIAL IS SET AT "2" ANDCANDELA SELECTION DIAL IS SET ACCORDING TO VALUESSHOWN ON RISER DRAWING PRIOR TO INSTALLATIONFP1FP1FA11/14/20NTSCESC SCHRAMMSCHULER-HAAS ELECTRIC CORPCAYUGA FLATSFIRE ALARM SYSTEMRISER WIRING AND DEVICE DETAILS