HomeMy WebLinkAboutVOLUME 1C100SITE CIVILLEGEND &NOTESDRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:PROFESSIONAL LICENSE NUMBERVERSIONSNO.DATEDESCRIPTION864 Mapleton RoadPrinceton, NJ 08540609.919.0099fax 609.919.0088a r c h i t e c t sikon.5www.ikon5architects.com238 LINDENAVENUEITHACA, NYLANDSCAPE ARCHITECT:FIRE PROTECTION, PLUMBING,MECHANICAL, ELECTRICAL ENGINEER:STRUCTURAL ENGINEER:CIVIL ENGINEER:ARCHITECT:1-17-2018TRT, FLS (E17-13)1 01.17.2018CONSTRUCTIONDOCUMENTS
C101EXISTINGSITECONDITIONSDRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:PROFESSIONAL LICENSE NUMBERVERSIONSNO.DATEDESCRIPTION864 Mapleton RoadPrinceton, NJ 08540609.919.0099fax 609.919.0088a r c h i t e c t sikon.5www.ikon5architects.com238 LINDENAVENUEITHACA, NYLANDSCAPE ARCHITECT:FIRE PROTECTION, PLUMBING,MECHANICAL, ELECTRICAL ENGINEER:STRUCTURAL ENGINEER:CIVIL ENGINEER:ARCHITECT:1-17-2018TRT, FLS (E17-13)101.17.2018CONSTRUCTIONDOCUMENTS
C102SITEDEMOLITIONDRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:PROFESSIONAL LICENSE NUMBERVERSIONSNO.DATEDESCRIPTION864 Mapleton RoadPrinceton, NJ 08540609.919.0099fax 609.919.0088a r c h i t e c t sikon.5www.ikon5architects.com238 LINDENAVENUEITHACA, NYLANDSCAPE ARCHITECT:FIRE PROTECTION, PLUMBING,MECHANICAL, ELECTRICAL ENGINEER:STRUCTURAL ENGINEER:CIVIL ENGINEER:ARCHITECT:1-17-2018TRT, FLS (E17-13)101.17.2018CONSTRUCTIONDOCUMENTS
EFFICIENCY330 SFEFFICIENCY330 SFENTRY LOBBYEFFICIENCY330 SFEFFICIENCY330 SFEFFICIENCY330 SF238 LINDEN AVENUEROW HOUSE HOUSINGLOWER LEVEL=734.5GROUND LEVEL=744.5C103SITEUTILITIESDRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:PROFESSIONAL LICENSE NUMBERVERSIONSNO.DATEDESCRIPTION864 Mapleton RoadPrinceton, NJ 08540609.919.0099fax 609.919.0088a r c h i t e c t sikon.5www.ikon5architects.com238 LINDENAVENUEITHACA, NYLANDSCAPE ARCHITECT:FIRE PROTECTION, PLUMBING,MECHANICAL, ELECTRICAL ENGINEER:STRUCTURAL ENGINEER:CIVIL ENGINEER:ARCHITECT:1-17-2018TRT, FLS (E17-13)101.17.2018CONSTRUCTIONDOCUMENTS
EFFICIENCY330 SFEFFICIENCY330 SFENTRY LOBBYEFFICIENCY330 SFEFFICIENCY330 SFEFFICIENCY330 SFCPT-1CPT-2STCPT-2 STCPT-2CPT-3CPT-1CPT-2CPT-1STCPT-2
STCPT-2 CPT-1CPT-2STCPT-2 STCPT-2 CPT-1CPT-2STCPT-2 STCPT-2 CPT-3CPT-1CPT-2ST
CPT-2STFEC FECEMCPT-1EMCPT-1238 LINDEN AVENUEROW HOUSE HOUSINGLOWER LEVEL=734.5GROUND LEVEL=744.5C104EROSION ANDSEDIMENTCONTROL PLANDRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:PROFESSIONAL LICENSE NUMBERVERSIONSNO.DATEDESCRIPTION864 Mapleton RoadPrinceton, NJ 08540609.919.0099fax 609.919.0088a r c h i t e c t sikon.5www.ikon5architects.com238 LINDENAVENUEITHACA, NYLANDSCAPE ARCHITECT:FIRE PROTECTION, PLUMBING,MECHANICAL, ELECTRICAL ENGINEER:STRUCTURAL ENGINEER:CIVIL ENGINEER:ARCHITECT:1-17-2018TRT, FLS (E17-13)101.17.2018CONSTRUCTIONDOCUMENTS
DRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:PROFESSIONAL LICENSE NUMBERVERSIONSNO.DATEDESCRIPTION864 Mapleton RoadPrinceton, NJ 08540609.919.0099fax 609.919.0088a r c h i t e c t sikon.5www.ikon5architects.com238 LINDENAVENUEITHACA, NYLANDSCAPE ARCHITECT:FIRE PROTECTION, PLUMBING,MECHANICAL, ELECTRICAL ENGINEER:STRUCTURAL ENGINEER:CIVIL ENGINEER:ARCHITECT:1-17-2018TRT, FLS (E17-13)101.17.2018CONSTRUCTIONDOCUMENTSC201SITEUTILITYDETAILS
DRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:PROFESSIONAL LICENSE NUMBERVERSIONSNO.DATEDESCRIPTION864 Mapleton RoadPrinceton, NJ 08540609.919.0099fax 609.919.0088a r c h i t e c t sikon.5www.ikon5architects.com238 LINDENAVENUEITHACA, NYLANDSCAPE ARCHITECT:FIRE PROTECTION, PLUMBING,MECHANICAL, ELECTRICAL ENGINEER:STRUCTURAL ENGINEER:CIVIL ENGINEER:ARCHITECT:1-17-2018TRT, FLS (E17-13)101.17.2018CONSTRUCTIONDOCUMENTSC202SITEPAVINGDETAILS
AL11RA8RA17HV12HV3BM17PQ25TURF LAWN, TYP.VV2800NK200VV600BM15VV700VV475NK45NK45NK60HH56AxF2HA2HA1DRY-LIN LLCTM# 64-10-7NST. No. 569175-004TOTAL AREA= 0.414 ACRES238 LINDEN AVENUEROW HOUSE HOUSING(2,813 SF FOOTPRINT)2L4.02SHRUBPLANTING1L4.02DECIDUOUS TREEPLANTING, TYP.2L4.02SHRUBPLANTING8L4.02CU-STRUCTURALSOIL PROFILE2L4.02MULTI-STEM ORNAMENTALTREE PLANTING, TYP.4L4.02LAWNESTABLISHMENT, TYP.7L4.02TREE AND SHRUB PLANTINGON STEEP SLOPES, TYP.5L4.02GROUNDCOVERPLANTING, TYP.6L4.02SLOPESTABILIZATION5L4.02GROUNDCOVERPLANTING, TYP.TREESSHRUBSSYMBOLQTYBOTANICAL NAMECOMMON NAMESIZEROOTCOMMENTSAcer x freemanii 'Sienna Glen'Sienna Glen MapleB&B3 12" -4" cal.2AxFHamamelis virginianaAmerican WitchhazelB&BMulti-stemFull /6'-8' ht3HVBMBuxus microphyllaKorean BoxwoodB&BHAHydrangea anomala petiolarisClimbing Hydrangea24"-30" Ht.PERENNIALS AND GROUNDCOVERSSpace as shown32Space 2.5' on centerNKNarcissus 'Kingscourt'Kingscourt DaffodilBulbsBULBSSpaced in odd groups350GENERAL SHEET NOTES1.SEE SPECIFICATIONS FOR PLANTING SOIL MIX REQUIREMENTS.2.SEE SPECIFICATIONS FOR SEED TYPE AND SEEDING RATE.3.CONTRACTOR TO PROVIDE IMPORTED PLANTING SOIL MIXES, PER SPECIFICATIONS.4.ALL PLANTING BEDS TO BE PREPARED AS SPECIFIED: SHRUB BEDS TO BE PREPARED IN THEIRENTIRETY TO 24" DEPTH WITH SPECIFIED SOILS. TREE PITS TO BE DUG TO MINIMUM DEPTHEQUAL TO THE ROOTBALL BY 3X THE DIAMETER. LAWN AREAS TO BE PREPARED WITH 8" OFTOPSOIL PER SPECIFICATIONS.5.AFTER BEDS ARE PREPARED, THE LANDSCAPE CONTRACTOR IS TO LOCATE TREES, SHRUBS ANDPERENNIALS AS SHOWN ON PLANS. TREE, SHRUB AND PERENNIAL LOCATIONS ARE TO BEAPPROVED BY LANDSCAPE ARCHITECT BEFORE THEY ARE PLANTED.6.ALL DISTURBED AREAS THAT ARE NOT SHOWN AS PAVED OR PLANTED BED ARE TO BERESTORED TO LAWN, UNLESS OTHERWISE INDICATED.7.APPLY EROSION CONTROL BLANKET TO ALL SLOPES 3:1 OR GREATER - REFER TOSPECIFICATIONS.8.TREES ARE TO RECEIVE 3' DIA. MULCH RINGS, UNLESS OTHERWISE INDICATED IN DRAWINGS.9.PROVIDE 30" OF GRAVEL MULCH AROUND ALL INLETS SET WITHIN PLANTING AREAS, UNLESSSHOWN OTHERWISE.Single stemHHHedera helixEnglish IvySP5Space 6" on center#5 cont.356contPQParthenocissus quinquefoliaVirginia CreeperSP4Space 3' on center25contALAmelanchier laevisAllegheny ServiceberryB&B11Multi-stemFull /6'-8' htRARhus aromatica "Low Grow"Fragrant Sumac#3 cont.18" -24" Ht.25Space 3' on centerDRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:PROFESSIONAL LICENSE NUMBERVERSIONSNO.DATEDESCRIPTION864 Mapleton RoadPrinceton, NJ 08540609.919.0099fax 609.919.0088a r c h i t e c t sikon.5www.ikon5architects.com Jan 17, 2018 - 9:30am238 LINDENAVENUEITHACA, NYLANDSCAPE ARCHITECT:FIRE PROTECTION, PLUMBING,MECHANICAL, ELECTRICAL ENGINEER:STRUCTURAL ENGINEER:CIVIL ENGINEER:ARCHITECT:TT-Logo-Newark.jpg01.17.2018TWMLAL4.01SITE PLANTINGPLAN AND SCHEDULE1PLANTING PLAN3/16"=1'-0"Hamamelis virginianaAmerican WitchhazelB&BSingle-stemFull /6'-8' ht2HV1VVVinca minor 'Bowles'Bowles Common PeriwinkleSP4Space 6" on center4100cont101.17.2018CONSTRUCTIONDOCUMENTS
Scale: 1/4"=1'-0"
SHRUB PLANTING3
NOTES:
1.PLANT AT SAME DEPTH AS PREVIOUSLY
PLANTED IN NURSERY OR CONTAINER
2.PROVIDE COMPACTED BASE UNDER ROOT
BALL ONLY TO PREVENT SETTLING
3" DOUBLE SHREDDED
HARDWOOD BARK MULCH IN ALL
PLANTING BED AREAS
UNTIE AND ROLL BACK BURLAP
FROM MIN. 1/3 OF ROOT BALL.
SYNTHETIC WRAP IS
UNACCEPTABLE. CUT WIRE
BASKETS AND REMOVE.
BACKFILL WITH SPECIFIED
PLANTING SOIL MIX OR DEEPLY
RIPPED SUBSOIL AMENDED AS
PER SPECIFICATIONS
SET ROOT BALL ON 4" MIN.
COMPACTED CLEAN FILL
TO PREVENT SETTLING4" MIN2' MINUNDISTURBED AND/OR
COMPACTED SUBGRADE 6"BALLDEPTHPLATFORM TO BE EQUAL OR
GREATER THAN ROOT BALL WIDTH3' MIN.12" MIN.Scale: 1/4"=1'-0"
MULTI-STEM ORNAMENTAL TREE/SHRUB PLANTING2
TOP OF UNDISTURBED AND/OR COMPACTED SUBGRADE
AFTER ROUGH GRADING
SET BALL ON COMPACTED CLEAN FILL TO PREVENT SETTLING
EXTEND STAKES INTO SUBGRADE SOIL
ROOTBALL, CUT&REMOVE BURLAP, ROPE, AND/OR WIRE
BASKET FROM TOP&SIDE OF ROOTBALL
BACKFILL WITH SPECIFIED PLANTING SOIL MIX
6" HIGH SOIL SAUCER TO DIRECT WATER INTO ROOTBALL
2"X2" SQ. WOOD STAKES (3 PER TREE)
DRAIN SOIL, UP TO 4" ABOVE GRADE IN POORLY
DRAINED SOILS KEEP MULCH AWAY FROM TRUNK BASE
TREE SHALL BE SET PLUMB
NOTES:
1.REMOVE ALL WIRE, PLASTIC, TAGS,
OR OTHER SYNTHETIC MATERIAL FROM
TREE PRIOR TO PLANTING.
3" DOUBLE SHREDDED HARDWOOD BARK MULCH BED, DO
NOT PLACE IN CONTACT WITH TRUNK
VARIES
FINISHED GRADE
3X WIDTH OF ROOT BALL
CLEAN FILL OR DEEPLY RIPPED SUBSOIL AMENDED
AS PER SPECIFICATIONS
Scale: 1/2"=1'-0"
DECIDUOUS TREE PLANTING1
TREE TRUNK
LONG PRONG
SHORT PRONG
DIRECTION OF DOMINANT SLOPE
PLAN
48" LONG TREE STAPLE
SET TREE PLUMB
CL TREE PRIMARY LEADER
3" DOUBLE SHREDDED HARDWOOD BARK
MULCH, DO NOT PLACE IN CONTACT WITH
TRUNK - REFER TO SPECIFICATIONS
KEEP MULCH AWAY FROM TRUNK AND TRUNK
FLARE
SCARIFY SIDES AND BOTTOM OF TREE PIT TO
PREVENT GLAZING OF SUBGRADE
UNTIE AND ROLL BACK BURLAP FROM 1/3 MIN.
OF ROOT BALL. SYNTHETIC WRAP IS
UNACCEPTABLE. CUT AND REMOVE
EVERYTHING EXCEPT BURLAP.
PRUNE AND REMOVE DEAD AND BROKEN
BRANCHES
BACKFILLED PLANTING SOIL MIX - REFER TO
SPECIFICATIONS
(3) 48" LONG TREE STAPLES - INSTALL AS PER
MANUFACTURER INSTRUCTIONS
PLANT SHALL BE SET AT OR SLIGHTLY ABOVE
THE ESTABLISHED FINISH GRADE
SET TREE ROOT BALL DIRECTLY ON
COMPACTED SUBGRADE SOIL PLINTH AS
NECESSARY TO RAISE TREE TO FINISH GRADE
ELEVATION
PREPARED SUBGRADE
NOTES:
1. PLACE TWO OF THREE TREE STAPLES ON
UPHILL SIDE OF ROOTBALL.
Scale: 1"=1'-0"
LAWN ESTABLISHMENT4
SPECIFIED LAWN SEED - APPLIED AT RATE
AS SPECIFIED AND ROLLED INTO SOIL
8" TURF SOIL. ROLL AND COMPACT TO 85%
PROCTOR DENSITY.
AERATED/ROTOTILLED SUBSOIL
UNDISTURBED AND/OR COMPACTED
SUBGRADE8"6"12" NATURAL COLOR HYDRO-MULCH
NOTES:
1.SEE L401 SOILS AND MULCH PLAN FOR EXTENTS.
Scale: 1"=1'-0"
CU-STRUCTURAL SOIL PROFILE8
SECTION2'-0"CU-STRUCTURAL SOIL -
REFER TO SPECIFICATIONS
PREPARED COMPACTED
SUBGRADE
DRAWING NOTES:
1. REFER TO L4.01 FOR EXTENT OF
CU-STRUCTURAL SOIL.
CONCRETE SIDEWALK -
REFER TO C-SERIES DWGS.
D = TYPICAL ON CENTER (O.C.)
SPACING AS INDICATED IN PLANT
SCHEDULE.
Scale: 1"=1'-0"
GROUNDCOVER PLANTING5
SECTIONPLAN
PREPARED COMPACTED SUBGRADE -
SEE NOTE #1
PRIOR TO PLANTING, REMOVE PLANT FROM
CONTAINER AND GENTLY COMB OUT ROOTS
FINISH GRADE OF PLANTING BED
3" DEPTH DOUBLE SHREDDED HARDWOOD BARK
MULCH OVER ENTIRE PLANTING BED AREA
PLANT THROUGH BIODEGRADABLE SLOPE
STABILIZATION FABRIC WHERE SLOPES
EXCEED 20% - REFER TO SPECIFICATIONS
PLANT CENTER
NOTE:
1. BACK FILL WITH CLEAN FILL OR DEEP RIPPED
SUBSOIL, AMENDED AS PER SPECIFICATIONS,
AS NECESSARY TO ESTABLISH SUBGRADE
ELEVATION.
BACKFILL WITH SPECIFIED PLANTING SOIL MIX
AS PER SPECIFICATIONS1'-6" MIN.Scale: AS NOTED
SLOPE STABILIZATION 6
DETAIL
ENLARGEMENT
SCALE: 1"=1'-0"
6"6"SECTION
N.T.S.
FINISH GRADE
12" LONG BIODEGRADABLE STAKES
PLACED IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS
BIODEGRADABLE SLOPE STABILIZATION
BLANKET WITH OVERLAP AS PER
MANUFACTURER'S RECOMMENDATIONS
BACKFILL WITH SPECIFIED PLANTING SOIL MIX
OR DEEPLY RIPPED SUBSOIL AMENDED AS PER
SPECIFICATIONS
BIODEGRADABLE SLOPE STABILIZATION
BLANKET
6" LONG BIODEGRADABLE STAKES
PLACED IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS
ENLARGEMENT OF
ANCHOR IN 6" X 6"
TRENCH AT CREST
OF SLOPE
NOTE:
1. INSTALL SLOPE STABILIZATION BLANKETS IN ALL
AREAS WHERE SLOPE IS 3:1 OR GREATER.
Scale: 1/4"=1'-0"
TREE AND SHRUB PLANTING ON STEEP SLOPES7
TOP OF UNDISTURBED AND/OR COMPACTED
SUBGRADE AFTER ROUGH GRADING
SET BALL ON COMPACTED CLEAN FILL TO
PREVENT SETTLING
EXTEND STAKES INTO SUBGRADE SOIL
ROOTBALL, CUT&REMOVE BURLAP, ROPE,
AND/OR WIRE BASKET FROM TOP&SIDE OF
ROOTBALL
BACKFILL WITH SPECIFIED PLANTING SOIL MIX
3" DIAMETER CEDAR WOOD STAKES (3 PER
TREE) WITH 3 4" WIDE FLAT WOVEN
POLYPROPYLENE TREE GUYING INSTALLED
AS PER MANUFACTURER'S INSTRUCTIONS
TREE OR SHRUB SHALL BE SET PLUMB
NOTES:
1.BACK FILL WITH CLEAN FILL OR DEEP RIPPED SUBSOIL, AMENDED AS PER
SPECIFICATIONS, AS NECESSARY TO ESTABLISH SUBGRADE ELEVATION.
2.REMOVE ALL WIRE, PLASTIC, TAGS,
OR OTHER SYNTHETIC MATERIAL FROM TREE PRIOR TO PLANTING.
3. PLACE TWO OF THREE WOOD STAKES ON UPHILL SIDE OF ROOTBALL.
2" DEPTH MULCH BED, DO NOT PLACE IN
CONTACT WITH TRUNK
CLEAN FILL OR DEEPLY RIPPED SUBSOIL
AMENDED AS PER SPECIFICATIONS
PREPARED COMPACTED SUBGRADE - SEE
NOTE #1
EQUAL OR GREATER
THAN ROOT BALL
EQUAL OR GREATER
THAN ROOT BALLVARIESPLAN DETAIL
FIRMLY COMPACTED SOIL SAUCER - MIN. 4" HT.
CORNER OF ROOTBALL TO BE SET AT LINE OF
DOMINANT SLOPE
DIRECTION OF SLOPE
SECTION
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE NUMBER
VERSIONS
NO.DATE DESCRIPTION
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
ikon.5
www.ikon5architects.com
Jan 16, 2018 - 5:46pm
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
TT-Logo-Newark.jpg
01.17.2018
TWMLA
L4.02
PLANTING
DETAILS
1 01.17.2018 CONSTRUCTION
DOCUMENTS
SYMBOLS REFERENCEDESCRIPTION
ELEVATION
ROOF TOP UNIT AND MAX OPERATING WEIGHT
X - INDICATES CHANGE IN T/STRUCTURAL SLAB ELEVATION
INDICATES SLOPE IN STRUCTURAL SLAB
GRID NUMBER
WORK POINT
OPENING IN FLOOR OR ROOF OPEN
SLOPE
SPREAD FOOTING TYPE AND TOP OF FOOTING ELEVATION IN
RELATIVE TOP OF SOG. TOP OF FOOTING AT STEEL COL IS AT
-12" IN RELATIVE TO TOP OF SOG . TYP UON.
F3
(-2'-6")
CONCRETE PIER. TOP OF PIER AT STEEL COL IS AT -12" IN
RELATIVE TO TOP OF SOG. TYP UON.
CONCRETE WALL
CONCRETE MASONRY UNIT WALL
SHEAR OR BEARING WALL BELOW (AND NOT ABOVE)
SHEAR OR BEARING WALL (ABOVE AND BELOW)
X"
RTU
1 1000 lbs
T/SLAB
EL = 0' - 0"
U P
?
DN
STEEL COLUMN
C-X SEE PLAN FOR
COLUMN SIZE NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018 CONSTRUCTION
DOCUMENTS
DRAWING LIST, SYMBOLS &
ABBREVIATIONS
S0.01
TT
01.17.2018
238 LINDEN AVENUE
STRUCTURAL DRAWING LIST ABBREVIATIONSSYMBOLS LEGEND
SHEET
NO SHEET NAME
S0.01 DRAWING LIST, SYMBOLS & ABBREVIATIONS
S0.02 GENERAL NOTES I
S0.03 GENERAL NOTES II
S0.04 GENERAL NOTES III
S1.00 LOWER LEVEL PLAN
S1.01 GROUND FLOOR FRAMING PLAN
S1.02 LEVEL 2 FRAMING PLAN
S1.03 LEVEL 3 FRAMING PLAN
S1.04 LEVEL 4 FRAMING PLAN
S1.05 ROOF LEVEL FRAMING PLAN
S2.01 FOUNDATION WALL SECTIONS I
S2.02 FOUNDATION WALL SECTIONS II
S2.03 FOUNDATION WALL SECTIONS III
S2.11 TYPICAL SLAB ON GRADE DETAILS
S2.12 TYPICAL SITE RETAINING WALL DETAILS AND
SCHEDULE
S2.13 TYPICAL SHALLOW FOOTING DETAILS AND
SCHEDULES
S2.14 TYPICAL SHALLOW FOOTING DETAILS AND
SCHEDULES
S2.15 TYPICAL SHALLOW FOOTING DETAILS
S2.16 GRADE BEAM DETAILS
S3.01 STAIR 1 FRAMING ELEVATIONS
S3.02 STAIR 2 FRAMING ELEVATIONS
S4.01 SECTION AT ENTRY STAIR
S5.01 TYPICAL STEEL COLUMN DETAILS
S5.02 TYPICAL STEEL BEAM DETAILS
S5.11 STEEL SECTIONS AND DETAILS I
S5.12 STEEL SECTIONS AND DETAILS II
S6.01 MASONRY TYPICAL DETAILS I
S6.02 MASONRY TYPICAL DETAILS II
S6.03 MASONRY TYPICAL DETAILS III
S6.04 MASONRY TYPICAL DETAILS IV
CONSTRUCTION DOCUMENTS JANUARY 17, 2018
ABBREVIATION DESCRIPTION
KLF KIP PER LINEAR FOOT
KSF KIP PER SQUARE FOOT
LG LIGHT GAGE
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG LONGITUDINAL
LP LOW POINT
LW LIGHTWEIGHT
LWC LIGHTWEIGHT CONCRETE
M MOMENT
MAX MAXIMUM
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL,
PLUMBING, FIRE PROTECTION
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NS NEAR SIDE
NTS NOT TO SCALE
NW NORMAL WEIGHT
NWC NORMALWEIGHT CONCRETE
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OH OPPOSITE HAND
OPNG(S) OPENING(S)
OPP OPPOSITE
P.D.F. POWER DRIVEN FASTENERS
PCY POUNDS PER CUBIC YARD
PERP PERPENDICULAR
PL PLATE
PRC PRECAST
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
RAD RADIUS
REF REFERENCE
REINF REINFORCE(D) (ING) OR (MENT)
REQD REQUIRED
S&T SHRINKAGE AND TEMPERATURE
SCHED SCHEDULE(D)
SDL SUPERIMPOSED DEAD LOAD
SECT SECTION
SF SQUARE FOOT (FEET)
SIM SIMILAR
SLRS SEISMIC LOAD RESISTING
SYSTEM
SOG SLAB ON GRADE
SP SPACE
SPEC(S) SPECIFICATION(S)
STD STANDARD
STL STEEL
STR STRUCTURE
STRCTL STRUCTURAL
T TENSION
T&B TOP AND BOTTOM
T/ TOP OF
TEMP TEMPERATURE OR TEMPORARY
TEN TENSION
THK THICK OR THICKNESS
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
V SHEAR
VERT VERTICAL
VIF VERIFY IN FIELD
W/ WITH
W/O WITHOUT
WP WORK POINT
WPFG WATERPROOFING
WS WATERSTOP
WWR WELDED WIRE REINFORCEMENT
ABBREVIATION DESCRIPTION
ADDL ADDITIONAL
ADJ ADJACENT
ALT ALTERNATE
APPRX APPROXIMATE
ARCH ARCHITECT OR ARCHITECTURAL
B/ BOTTOM OF
B/B BACK TO BACK
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BOT BOTTOM
BRDG BRIDGING
BRG BEARING
BTWN BETWEEN
C COMPRESSION
C/C CENTER TO CENTER
CIP CAST-IN-PLACE
CL CENTER LINE
CLR CLEAR OR CLEARANCE
CMU CONCRETE MASONRY UNIT
COL COLUMN
COMP COMPRESSION
CONC CONCRETE
CONN CONNECTION(S)
CONST CONSTRUCTION
CONT CONTINUOUS
db REINFORCING BAR DIAMETER
DBL DOUBLE
DCW DEMAND CRITICAL WELD
DEG DEGREE(S)
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIM(S) DIMENSION(S)
DL DEAD LOAD
DWG(S) DRAWING(S)
DWL DOWEL(S)
EA EACH
ECC ECCENTRICITY
EF EACH FACE
EL ELEVATION
ELEC ELECTRICAL
ENGR ENGINEER
EOD EDGE OF DECK
EOS EDGE OF SLAB
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EXP EXPANSION
EXST EXISTING
EXT EXTERIOR
F/F FACE TO FACE
FIN FINISH(ED)
FLR FLOOR
FND FOUNDATION
FP FIREPROOF(ING)
FS FAR SIDE
FTG FOOTING
GA GAGE, GAUGE
GALV GALVANIZED
GB GRADE BEAM
GEN GENERAL
GR GRADE
HK HOOK
HORIZ HORIZONTAL
HP HIGH POINT
ID INSIDE DIAMETER
IF INSIDE FACE
INFO INFORMATION
INT INTERIOR
INTRM INTERMEDIATE
JT JOINT
K KIPS (1,000 POUNDS)
LOCATION
MIN
COMPRESSIVE
STRENGTH (PSI)
MAX
WEIGHT
(PCF)
MIN/MAX %
CLASS F
FLY ASH
MIN/MAX %
SLAG
MAX TOTAL
% FLY ASH
AND SLAG
FOOTINGS /
GRADE BEAMS
SLAB ON GRADE
WALLS / COLUMNS 4000 @ 28 DAYS 145 15-30 0-50 50
CD CODES AND DESIGN CRITERIA
CD-1)PERFORM ALL CONSTRUCTION IN CONFORMANCE WITH THE BUILDING AND
DESIGN CODES REFERENCED WITHIN THESE DOCUMENTS. THE PROJECT
DOCUMENTS REFER TO THE FOLLOWING CODES AND STANDARDS, UON:
2015 INTERNATIONAL BUILDING CODE, NEW YORK STATE EDITION
STRUCTURAL COCNRETE
"BUILDING CODE REQUIREMENT FOR STRUCTURAL COCNRETE
THE AMERICAN CONCRETE INSTITUTE (ACI 318- 12)
CONCRETE MASONRY
"BUILDING CODE REQUIREMENT FOR CONCRETE MASONRY STRUCTURES"
THE AMERICAN CONCRETE INTITUTE (ACI 530 - 13)
STRUCTURAL STEEL
"SPECIFICATION FOR STRUCUTRAL STEEL BUILDINGS"
THE AMERICAN INSTITUTE OF STEEL CONSTRUTION (ANSI/AISC 360-10)
CD-2)RISK CATEGORY: II RESIDENTIAL HOUSE
CD-3)LIVE LOADS:
RESIDENTIAL 40 LBS./SQ. FT.
ELEVATOR LOBBIES 80 LBS./SQ. FT.
CORRIDORS ABOVE FIRST FLOOR 80 LBS./SQ. FT.
ALL OTHER LOBBIES & CORRIDORS 100 LBS./SQ. FT.
EXIT FACILITIES 100 LBS./SQ. FT.
LIGHT STORAGE AREA 100 LBS./SQ. FT.
MECHANICAL ROOMS 150 LBS/SQ. FT. OR ACTUAL WEIGHT
SIDEWALKS 250 LBS./SQ. FT.
ROOFS 30 LBS./SQ. FT. [UNREDUCED]
CD-4)SNOW LOADS:
FLAT ROOF SNOW LOAD (Pf):28 PSF
GROUND SNOW LOAD (Pg)40 PSF
SNOW EXPOSURE FACTOR (Ce):0.9
SNOW LOAD IMPORTANCE FACTOR (Is):1.0
THERMAL FACTOR (Ct):1.0
SNOW DRIFTING PER CODE
CD-5)WIND LOAD DESIGN DATA:
MAIN WIND FORCE RESISTING SYSTEM
BASIC WIND SPEED, V 120 MPH
EXPOSURE B
RISK/OCCUPANCY CATEGORY II
WIND IMPORTANCE FACTOR (Iw)1.0
BUILDING CATEGORY II
INTERNAL PRESSURE COEFFICIENT ± 0.18
COMPONENT AND CLADDING DESIGN PRESSURES a=5’-0”
EFFECTIVE WIND AREA= 50 SF
WALL= +24.47 / -26.74 PSF
WALL END ZONE= +24.47/ -30.78 PSF
ROOF EFFECTIVE WIND AREA = 20 SF
ROOF= +16 / -29.04 PSF
ROOF EDGE = +16 / -44.68 PSF
ROOF CORNER= +16 / -62.34 PSF
DI DELEGATED DESIGN ITEMS
DI-1)THE CONTRACTOR SHALL EMPLOY OR RETAIN A PROFESSIONAL ENGINEER
LICENSED IN THE STATE OF NEW YORK TO DESIGN AND DETAIL DELEGATED
DESIGN ITEMS TO MEET THE PERFORMANCE AND DESIGN CRITERIA
ESTABLISHED AS PART OF THE BASE BUILDING STRUCTURE INDICATED IN
THE CONTRACT DOCUMENTS INCLUDING BUT NOT LIMITED TO:
STRUCTURAL STEEL CONNECTIONS
COLD FORMED METAL FRAMING
STEEL FLOOR DECK
STEEL ROOF DECK
FN FOUNDATIONS
FN-1)THE FOUNDATION DESIGN IS BASED ON THE GEOTECHNICAL INVESTIGATION
REPORT BY JOHN P. STOPEN ENGINEERING,LLP DATED OCTOBER 10,2017 ALONG
WITH SUPLEMENTAL GEOTECHNICAL RECOMMENDATIONS PROVIDED ON 1/8/2018 .
FN-2)FOUNDATIONS HAVE BEEN DESIGNED BASED ON THE FOLLOWING DESIGN
VALUES FROM THE GEOTECHNICAL INVESTIGATION REPORT:
BEARING STRATUM COMPETENT SUBGRADE
NET ALLOWABLE BEARING CAPACITY: 3,000PSF
SEE GEOTECHNICAL REPORT FOR ADDITIONAL REQUIREMENTS AND
INFORMATION. DESIGN VALUES SHALL BE FIELD VERIFIED BY QUALIFIED
GEOTECHNICAL CONSULTANT RETAINED BY THE OWNER .
FN-3)THE CONTRACTOR SHALL VERIFY FOUNDATION INSTALLATION AND
CONSTRUCTION IS IN CONFORMANCE WITH THE RECOMMENDATIONS OUTLINED IN
THE GEOTECHNICAL REPORT.
FN-4)CONTRACTOR SHALL BE RESPONSIBLE TO ADEQUATELY PROTECT ALL
EXCAVATION. WHERE NECESSARY, SHEET AND SHORE THE EXCAVATION WITH ALL
REQUIRED TIEBACKS AND BRACING AS DETERMINED BY CONTRACTOR'S
STRUCTURAL ENGINEER.
FN-5)PROVIDE BRACING FOR ALL BASEMENT FOUNDATION WALLS PRIOR TO
BACKFILLING. THIS BRACING SHALL REMAIN IN PLACE UNTIL ALL SLABS AND
BEAMS FRAMING INTO WALL HAVE BEEN PLACED AND HAVE ATTAINED 100
PERCENT OF THEIR DESIGN STRENGTH.
FN-6)DO NOT BACKFILL AGAINST CANTILEVER RETAINING WALLS UNTIL THE
CONCRETE HAS ATTAINED 100 PERCENT OF ITS DESIGN STRENGTH.
CM-2)ALL CONCRETE SHALL BE THOROUGHLY CONSOLIDATED.
CM-3)THE USE OF CALCIUM CHLORIDE AND OTHER CHLORIDE CONTAINING
AGENTS IS PROHIBITED. THE USE OF RECYCLED CONCRETE IS PROHIBITED.
PLACEMENT WITHIN AND CONTACT BETWEEN ALUMINUM ITEMS, INCLUDING
ALUMINUM CONDUIT, AND CONCRETE IS PROHIBITED.
CM-4)ALL CAST-IN-PLACE CONCRETE WILL EXPERIENCE DIFFERING VARIATIONS
OF CRACKING. ANY ELEMENT EXPOSED TO DIRECT WEATHER AND/OR
TEMPERATURE VARIATIONS DURING CONSTRUCTION OR IN THE FINAL CONDITION
IS TO BE TREATED AND REGULARLY MAINTAINED TO PREVENT PROPAGATION OF
CRACKS AND WATER PENETRATION. THE CONTRACTOR SHALL DEVELOP A
REGULAR MAINTENANCE PROGRAM AND SUBMIT IT TO THE OWNER.
GR GENERAL REQUIREMENTS
GR-1)AS USED IN THESE GENERAL NOTES:
"DRAWINGS" MEANS THE LATEST STRUCTURAL DESIGN DRAWINGS, UON.
"SPECIFICATIONS" MEANS THE LATEST PROJECT SPECIFICATIONS, UON.
“CONTRACT DOCUMENTS” IS DEFINED AS THE DESIGN DRAWINGS AND THE
SPECIFICATIONS
“SER” IS DEFINED AS THE STRUCTURAL ENGINEER OF RECORD FOR THE
STRUCTURE IN ITS FINAL CONDITION.
“DESIGN PROFESSIONALS” IS DEFINED AS THE OWNER’S ARCHITECT AND SER.
“MEP” INCLUDES, BUT IS NOT LIMITED TO MECHANICAL, ELECTRICAL, PLUMBING,
FIRE PROTECTION.
“CONTRACTOR” IS DEFINED TO INCLUDE ANY OF THE FOLLOWING: GENERAL
CONTRACTOR AND THEIR SUBCONTRACTORS, CONSTRUCTION MANAGER AND
THEIR SUBCONTRACTORS, STRUCTURAL STEEL FABRICATOR OR STRUCTURAL
STEEL ERECTOR.
“BASE BUILDING STRUCTURE” IS DEFINED AS THE STRUCTURAL FRAME DESIGNED
BY THORNTON TOMASETTI.
“STRUCTURE IN ITS FINAL CONDITION” MEANS ALL STRUCTURAL ELEMENTS SHOWN
ON THE STRUCTURAL CONTRACT DOCUMENTS ARE INSTALLED AND COMPLETELY
CONNECTED AND INSPECTED WITH NO OUTSTANDING NON-COMPLIANCE ISSUES.
GR-2)THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF THE STRUCTURAL
WORK WITH THE ARCHITECTURAL, CIVIL, MEP CONTRACT DOCUMENTS, AS WELL AS
ANY OTHER APPLICABLE TRADES.
GR-3)THE CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE
UNTIL THE CONSTRUCTION OF THE STRUCTURE REACHES ITS FINAL CONDITION.
GR-4)THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE DESIGN, INSTALLATION,
AND REMOVAL OF TEMPORARY BRACING AND CONSTRUCTION SUPPORTS, FOR NEW
AND EXISTING STRUCTURES, AS NECESSARY TO COMPLETE THE PROJECT. NO
PORTION OF THE PROJECT WHILE UNDER CONSTRUCTION IS INTENDED TO BE
STABLE IN THE ABSENCE OF THE CONTRACTOR’S TEMPORARY SUPPORTS AND
BRACES. CONTRACTOR SHALL RETAIN A STRUCTURAL ENGINEER LICENSED IN THE
STATE IN WHICH THE PROJECT IS LOCATED TO DESIGN TEMPORARY BRACING AND
CONSTRUCTION SUPPORTS.
GR-5)LATERAL LOAD RESISTANCE AND STABILITY OF THE STRUCTURE IN ITS
FINAL CONDITION IS PROVIDED BY SHEARWALLS, AND LATERAL STABILITY OF
OTHER ELEMENTS IS PROVIDED THROUGH FLOOR SLABS AND ROOF DECK.
GR-6) THE SPECIFICATIONS ARE AN INTEGRAL PART OF THE CONTRACT
DOCUMENTS AND SHALL BE USED IN CONJUNCTION WITH THE STRUCTURAL
DRAWINGS.
GR-7)THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS
AND COORDINATE WITH THE STRUCTURAL DRAWINGS, ARCHITECTURAL DRAWINGS,
DRAWINGS FROM OTHER CONSULTANTS, PROJECT SHOP DRAWINGS AND FIELD
CONDITIONS.
GR-8)IN CASES OF CONFLICT BETWEEN DRAWINGS AND/OR SPECIFICATIONS AND
OTHER DISCIPLINES OR EXISTING CONDITIONS, CONTRACTOR SHALL NOTIFY THE
DESIGN PROFESSIONALS AND OBTAIN CLARIFICATION PRIOR TO BIDDING AND
PROCEEDING WITH WORK.
GR-9)APPLY DETAILS, SECTIONS, AND NOTES ON THE DRAWINGS WHERE
CONDITIONS ARE SIMILAR TO THOSE INDICATED BY DETAIL, DETAIL TITLE OR NOTE.
GR-10)ONLY USE DIMENSIONS INDICATED ON THE DRAWINGS. DO NOT SCALE
DRAWINGS.
GR-11)ASSUME EQUAL SPACING BETWEEN ESTABLISHED DIMENSIONS, IF NOT
INDICATED ON DRAWINGS.
GR-12)CENTERLINES OF COLUMNS AND FOUNDATIONS COINCIDE WITH GRID LINE
INTERSECTIONS, UON.
GR-13)CENTERLINES OF GRADE BEAMS AND WALLS COINCIDE WITH CENTERLINES
OF FOUNDATIONS, UON.
GR-14)CENTERLINES OF FRAMING MEMBERS COINCIDE WITH COLUMN
CENTERLINES, UON.
GR-15)THE CONTRACTOR SHALL PROTECT EXISTING FACILITIES, STRUCTURES
AND UTILITIES FROM DAMAGE.
GR-16)THE CONTRACTOR SHALL VERIFY THAT CONSTRUCTION LOADS DO NOT
EXCEED THE CAPACITY OF THE STRUCTURE AT THE TIME THE LOAD IS APPLIED.
GR-17) THE CONTRACTOR SHALL COORDINATE THE BOTTOM OF BASE PLATE
ELEVATIONS WITH THE AS-BUILT TOP OF SUPPORT ELEVATIONS.
GR-18)THE CONTRACTOR SHALL VERIFY ALL OPENING SIZES AND LOCATIONS
WITH OTHER DISCIPLINES. THE DRAWINGS DO NOT SHOW ALL OPENINGS
REQUIRED. ADDITIONAL OPENINGS, BLOCKOUTS AND SLEEVES MAY BE REQUIRED
BY OTHER DISCIPLINES AND SHALL BE CONSTRUCTED USING THE TYPICAL DETAILS
AND/OR THE CRITERIA INDICATED ON THE DRAWINGS. OPENINGS REQUIRED BUT
NOT SHOWN ON THE STRUCTURAL DRAWINGS MUST BE APPROVED BY THE
STRUCTURAL ENGINEER.
GR-19)ELEVATIONS INDICATED ON STRUCTURAL DRAWINGS ARE BASED ON A
PROJECT DATUM INDICATED ON THE ARCHITECTURAL DRAWINGS.
LOCATION
CONCRETE CAST AGAINST AND
PERMANENTLY EXPOSED TO EARTH
CONCRETE EXPOSED TO EARTH OR WEATHER:
CONCRETE NOT EXPOSED TO WEATHER OR IN
CONTACT WITH GROUNDSLABS, WALLS, JOISTS:
NO 11 BARS OR SMALLER.........................................................
NO 14 BARS AND LARGER.........................................................
BEAMS, COLUMNS:
PRIMARY REINFORCEMENT, TIES,
STIRRUPS, SPIRALS...................................................................
SHELLS, FOLDED PLATE MEMBERS:
COVER
3"
1 1/2"
2"
3/4"
1 1/2"
1 1/2"
1/2"
3/4"
RE CONCRETE REINFORCEMENT
RE-1) ALL CONCRETE SHALL INCLUDE REINFORCEMENT. IF REINFORCEMENT IS NOT SPECIFICALLY
INDICATED ON THE DRAWINGS, VERIFY WITH THE STRUCTURAL ENGINEER BEFORE PROCEEDING
WITH WORK.
RE-2) REINFORCEMENT SHALL CONFORM TO THE FOLLOWING STANDARDS AND MATERIAL
PROPERTIES:
DEFORMED BARS:ASTM A615, GRADE 60, UON
WELDABLE DEFORMED BARS:ASTM A706, GRADE 60, UON
EPOXY COATED DEFORMED BARS:ASTM A615, GRADE 60, UON / A775
WELDED WIRE REINFORCEMENT ASTM A185
EPOXY COATED WELDED WIRE REINFORCEMENT ASTM A185 / A884
WELDED BAR ANCHORS:NELSON D2L DEFORMED BAR ANCHORS
(ICC-ES REPORT ER-5217)
RE-3) DETAIL REINFORCEMENT BASED ON THE PROJECT REQUIREMENTS, ACI-318 AND ACI-315, UON.
RE-4) WHERE A 90-DEG, 135 -DEG OR 180-DEG HOOK IS GRAPHICALLY INDICATED, PROVIDE
CORRESPONDING ACI STANDARD HOOKS, UON.
RE-5) DOWELS SHALL MATCH SIZE AND SPACING OF MAIN REINFORCEMENT, UON.
RE-6) REINFORCEMENT SHALL HAVE CONCRETE PROTECTION (CLEAR COVER) PER ACI 318 UNLESS
OTHERWISE INDICATED ON THE DRAWINGS.
RE-11) PROVIDE LAP LOCATIONS AS FOLLOWS, UON:
A. GRADE BEAM / WALL (TOP HORIZONTAL REINFORCEMENT): AT CENTER OF SPAN
B. GRADE BEAM / WALL (BOTTOM HORIZONTAL REINFORCEMENT): AT SUPPORTS
C. WALL INSIDE FACE ( VERTICAL REINFORCEMENT): AT SUPPORT
D. WALL OUTSIDE FACE ( VERTICAL REINFORCEMENT): AT MIDHEIGHT OF WALL
E. UNLESS OTHERWISE NOTED TERMINATE BARS AT DISCONTINUOUS ENDS WITH
STANDARD HOOKS
RE-12) PROVIDE EPOXY COATED REINFORCEMENT AND ACCESSORIES IN AREAS OF DIRECT
EXPOSURE TO THE ENVIRONMENT, CHEMICALS, OR DE-ICING FOR THE AREAS INDICATED
ON THE DRAWINGS.
RE-13) TERMINATION OF REINFORCEMENT, UON:
A. TERMINATE ALL BARS IN LAPS, 90 DEGREE BENDS, OR WITH DOWELS INTO EXISTING
CONCRETE.
B. BEND TOP MAT OR FOOTING BARS DOWN TO BOTTOM BARS AT ENDS.
C. BEND BOTTOM MAT OR FOOTING BARS UP WITH STANDARD 90 DEGREE BENDS.
D. PROVIDE DOWELS FROM FOOTINGS AND SLABS INTO WALLS AND COLUMNS TO MATCH SIZE
AND SPACING OF VERTICAL REINFORCEMENT.
NO 11 BARS OR SMALLER.........................................................
NO 14 BARS AND LARGER.........................................................
NO 5 BARS OR SMALLER...........................................................
NO 6 BARS AND LARGER...........................................................
RE-7) LAP REINFORCEMENT AS SPECIFICALLY DETAILED ON THE DRAWINGS. SEE REBAR
OFFSET AND LAP SPLICE SCHEDULE,S0.05.
RE-8) UNLESS OTHERWISE NOTED ALL LAP SPLICES ARE TO BE CLASS "B" SPLICES PER
REBAR OFFSET AND LAP SPLICE SCHEDULE, S0.05].
RE-9) PROVIDE MECHANICAL SPLICES FOR BARS LARGER THAN #11 OR WHERE
INDICATED.
PROVIDE TENSILE, PRE-QUALIFIED, WELDED OR THREADED MECHANICAL SPLICES UON.
RE-10) LAP WELDED WIRE REINFORCEMENT PER S0.05, UON.
CD-6)SEISMIC LOAD DESIGN DATA:
SEISMIC IMPORTANCE FACTOR (Ie)1.0
Ss 0.126 g
S1 0.056 g
SDS 0.084 g
SD1 0.037 g
SITE CLASS D
SEISMIC DESIGN CATEGORY A
LATERAL SYSTEM DESCRIPTION SHEAR WALLS
SEISMIC RESPONSE COEFFICIENT (Cs)0.0154
RESPONSE MODIFICATION FACTOR (R)6.5
ANALYSIS PROCEDURE DESCRIPTION EQUIVALENT LATERAL FORCE
DESIGN BASE SHEAR 35 KIPS [NOT GOVERNING]
COMPONENT IMPORTANCE FACTOR (Ip)1.0
CD-7)IN CASES WHERE THE CONTRACTOR DETERMINES THAT SUSPENDED OR
FLOOR MOUNTED MEP EQUIPMENT LOADS EXIST WHICH EXCEED DESIGN LOADS
INDICATED ON CONTRACT DOCUMENTS, CONTRACTOR SHALL SUBMIT LOAD DATA
TO DESIGN PROFESSIONALS FOR REVIEW PRIOR TO PROCEEDING WITH WORK.
CD-8)DISTRIBUTE THE MAXIMUM LOAD HUNG FROM ANY STRUCTURAL MEMBER
FOR MEP DUCTWORK, PIPING ETC OVER THE MEMBER’S TRIBUTARY AREA IN A
WAY THAT THE DESIGN SUPERIMPOSED DEAD LOADS LISTED IN CONTRACT
DOCUMENTS ARE NOT EXCEEDED. THE CONTRACTOR SHALL COORDINATE THE
LOADS OF ALL TRADES AND PROVIDE ADDITIONAL SUPPORT OR DISTRIBUTION
FRAMING AS REQUIRED TO ACHIEVE THE ALLOWABLE LOAD DISTRIBUTION.
CD-10)ELEVATOR GUIDERAIL SUPPORTS, MACHINE ROOMS, PITS, AND
PENTHOUSES ARE BASED ON ELEVATOR TYPES INDICATED ON ARCHITECTURAL
CONTRACT DOCUMENTS. CONTRACTOR SHALL SUBMIT FOR REVIEW ANY
PLANNED CHANGE TO ELEVATORS TO DESIGN PROFESSIONALS PRIOR TO
SUBMITTING CORRESPONDING STRUCTURAL SHOP DRAWINGS FOR ACTION.
CD-11)STRUCTURAL COMPONENTS ARE NOT DESIGNED FOR VIBRATING
EQUIPMENT. MOUNT VIBRATING EQUIPMENT ON VIBRATION ISOLATORS.
CD-12)SERVICEABILITY
LIVE LOAD DEFLECTION IS LESS THAN L/360
LONG-TERM TOTAL DEFLECTION IS LESS THAN L/240
EXTERIOR SPANDRELS HAVE BEEN DESIGNED TO LIMIT LIVE LOAD MIDSPAN
VERTICAL DEFLECTION TO L/360 OF THE SPAN OR 1/2", WHICHEVER IS LESS.
EXTERIOR SPANDRELS HAVE BEEN DESIGNED TO LIMIT DEAD PLUS
SUPERIMPOSED DEAD LOAD MIDSPAN VERTICAL DEFLECTION TO 1L/240 OF THE
SPAN OR 3/4”, WHICHEVER IS LESS.
LATERAL DRIFT DUE TO WIND LOADS IS LESS THAN OR EQUAL TO H/400
CD-13)CONNECTIONS OF SYSTEMS DESIGNED BY CONTRACTOR’S ENGINEER
SUCH AS, BUT NOT LIMITED TO, CLADDING, STAIRS, ELEVATORS, ESCALATORS,
PRECAST STADIA, AND MEP LOADS ARE ASSUMED TO IMPOSE VERTICAL AND/OR
HORIZONTAL LOADS ON THE BASE BUILDING STRUCTURAL MEMBERS WITHOUT
GENERATING TORSION IN THE SUPPORTING STRUCTURAL MEMBERS.
CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING ALL
SUPPLEMENTARY BRACING MEMBERS AS REQUIRED TO PREVENT TORSION ON
THE BASE BUILDING STRUCTURE.
CD-14)FOR FIRE RATING AND FIREPROOFING ASSEMBLY EVALUATIONS,
CONSIDER THE FOLLOWING ASSEMBLIES RESTRAINED: COMPOSITE WIDE-
FLANGE STEEL FRAMING, INTERIOR BAYS OF CONTINUOUS CAST-IN-PLACE
CONCRETE CONSTRUCTION. CONSIDER ALL OTHER ASSEMBLIES UNRESTRAINED.
CM CONCRETE MATERIALS
CM-1)CONCRETE STRENGTHS AND WEIGHT (SEE SPECIFICATION SECTION 03 30
00 FOR ADDITIONAL CONCRETE PROPERTIES):
4000 @ 28 DAYS 145 15-30 0-50 50
NON SHRINK GROUT 8000 @ 28 DAYS
FOUNDATION WALLS 4000 @ 28 DAYS 145 15-30 0-50
SITE RETAINING
WALLS
4000 @ 28 DAYS 145 15-30 0-50
50
50
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
GENERAL NOTES I
S0.02
TT
01.17.2018
EXPANSION ANCHOR
FASTENED PART
CONCRETE SUBSTRATE
MASONRYHnom DEPTHHOLEEXPANSION ANCHOR
FASTENED PART
HnomCONCRETE SUBSTRATE
DEPTHHOLECONCRETE SLAB
REBAR
EPOXY ANCHORS IN NORMAL-WEIGHT CONCRETE (3000 PSI MIN)
TENSION TEST VALUE (LBS)
#3
#4
#5
#6
#7
EMBEDMENT
(IN)
3
4
5
6
7
SIZE
* LISTED EPOXY ADHESIVE MAY NOT BE USED WITH NOTED REBAR SIZES
HILTI
HIT-HY 200
5180
8130
11120
12260
2900
HILTI
HIT-RE
1670
2600
3750
4320
940
SIMPSON
1040
3740
5260
6740
8020
SET-XP
EPOXY ANCHORS IN NORMAL-WEIGHT CONCRETE (3000 PSI MIN)
TENSION TEST VALUE (LBS)
EMBEDMENT
(IN)
3
4
5
6
7
4480
7030
10180
11710
2500
2110
3170
4450
4720
1230 1700
2600
3450
4440
5540
ROD
THREADED
DIAMETER
3/4
3/8
1/2
5/8
7/8
(IN)
500-SD
HILTI
HIT-HY 200
HILTI
HIT-RE SIMPSON
SET-XP500-SD
ANCHOR
1/4"
3/8"
1/2"
5/8"
3/4"
2 1/2"
2 1/2"
3"
3 1/4"
4"
DIAMETER
1920
2405
2800
3780
1040
HILTI KWIK HUS-EZ IN NORMAL WEIGHT CONCRETE (3000 PSI MIN)
ANCHOR
SIMPSON TITEN HD IN NORMAL WEIGHT CONCRETE (3000 PSI MIN)
TENSION TEST
VALUE (LBS)DIAMETER
2 1/2"
3 1/4"
5 1/2"
1100
2730
5410
PA-6) EXPANSION ANCHORS
A.EXPANSION ANCHORS SHALL BE EITHER ONE OF THE FOLLOWING, UON:
HILTI KWIK BOLT TZ
(ICC-ES REPORT ESR-1917)
SIMPSON STRONG-BOLT 2
(ICC-ES REPORT ESR-3037)
USE OF CARBON STEEL EXPANSION ANCHORS IS LIMITED TO DRY,
INTERIOR LOCATIONS. USE STAINLESS STEEL EXPANSION ANCHORS AT
EXTERIOR, WEATHER-EXPOSED, OR DAMP LOCATIONS.
B. ANCHOR EMBEDMENTS BELOW ARE TO BE USED WHEN EXPLICITLY
SPECIFIED IN THE STRUCTURAL DRAWINGS. FOR LOCATIONS WHERE TENSION
TEST VALUES ARE NOT SPECIFIED IN THE DRAWINGS, CONSULT WITH THE SER.
PA-9) EPOXY ANCHORS AND DOWELS
A.EPOXY SHALL BE EITHER ONE OF THE FOLLOWING, UON:
HILTI HIT-HY 200 (ICC-ES REPORT ESR-3187)
HILTI HIT-RE 500-SD (ICC-ES REPORT ESR-2322)
SIMPSON SET-XP (ICC-ES REPORT ESR-2508)
B.RODS EMBEDDED IN EPOXY SHALL BE CARBON STEEL THREADED RODS PER THE
EPOXY MANUFACTURER'S ICC-ES REPORT. FOR HILTI HIT-HY 200 EPOXY, HILTI HIT-Z
ANCHOR RODS MAY BE SUBSTITUTED FOR THREADED RODS AT CONTRACTOR'S
OPTION.
C.REINFORCING STEEL BARS EMBEDDED IN EPOXY SHALL BE ASTM A615,
GRADE 60, UON.
D. ANCHOR EMBEDMENT AND TENSION TEST VALUES BELOW ARE TO BE USED WHEN
EXPLICITLY SPECIFIED IN THE STRUCTURAL DRAWINGS. FOR LOCATIONS WHERE
TENSION TEST VALUES ARE NOT SPECIFIED IN THE DRAWINGS, CONSULT WITH THE
SER.
C.Hnom IS MEASURED FROM FACE OF CONCRETE SUBSTRATE TO THE END OF THE
BOLT.
D.CONTRACTOR SHALL PROVIDE ANCHORS WITH SUFFICIENT TOTAL LENGTH FOR THE
SPECIFIED EMBEDMENT LENGTH, THICKNESS OF FASTENED PART, WASHER AND NUT.
E. THE DEPTH OF THE DRILLED HOLES MUST EXCEED THE SPECIFIED ANCHOR
EMBEDMENT LENGTH BY A SUFFICIENT AMOUNT TO PERMIT THE ANCHORS TO BE
INSTALLED TO A MINIMUM OF SIX THREADS BELOW THE SUBSTRATE SURFACE
E.TESTING OF EPOXY DOWELS AT JOINTS BETWEEN NEW AND EXISTING
SLABS-ON-GRADE IS NOT REQUIRED.
F.TESTING OF #3 EPOXY DOWELS AT CURBS IS NOT REQUIRED.
G.TESTING SHALL OCCUR AFTER EPOXY HAS CURED, AS PER MANUFACTURER'S
RECOMMENDATIONS.
H.OVERHEAD AND/OR CONSTANT TENSION EPOXY ANCHOR INSTALLATIONS NOT
SHOWN ON THE DRAWINGS SHALL NOT BE PERMITTED UNLESS EACH CONDITION
IS REVIEWED AND APPROVED IN WRITTING BY SER.
I.EPOXY ANCHORS SHALL BE INSTALLED IN CONCRETE HAVING A MINIMUM AGE OF
21 DAYS AT TIME OF ANCHOR INSTALLATION.
J.INSTALLATION AND INSPECTION OF EPOXY ANCHORS SHALL COMPLY WITH ACI
318-11 APPENDIX D SECTIONS D.9.2.2 AND D.9.2.4.
K. FOR USES OF EPOXY DOWELS NOT EXPLICITLY SPECIFIED IN THE STRUCTURAL
DRAWINGS, CONTACT THE SER.
PA-10) POWDER-ACTUATED FASTENERS (PAF):
A.POWDER-ACTUATED FASTENERS SHALL BE EITHER ONE OF THE FOLLOWING,
UON:
HILTI X-U (ICC-ES REPORT ESR-2269) AT METAL.
HILTI X-CP72 (ICC-ES REPORT ESR-2379) AT PTDF.
SIMPSON POWER-DRIVEN FASTENERS (ICC-ES REPORT ESR-2138)
B.PROVIDE 0.08" THICK x 1.1" SQUARE OR 1.425" ROUND WASHERS FOR ALL
POWDER-ACTUATED FASTENERS.
C.THE MINIMUM EMBEDMENT OF POWDER-ACTUATED FASTENERS INTO CONCRETE
SHALL BE 1", UON.
D. THE EMBEDMENT OF POWDER-ACTUATED FASTENERS INTO STEEL SHALL BE
THAT REQUIRED BY THE PAF MANUFACTURER, UON.
E.TESTING OF POWDER-ACTUATED FASTENERS IS NOT REQUIRED.
PA POST-INSTALLED ANCHORS
PA-1) POST-INSTALLED ANCHORS INCLUDE EXPANSION ANCHORS, SCREW
ANCHORS, EPOXY ANCHORS/DOWELS, AND POWDER-ACTUATED FASTENERS.
PA-2) INSTALL POST-INSTALLED ANCHORS IN ACCORDANCE WITH THE
APPLICABLE ICC-ES REPORT AND THE MANUFACTURER'S RECOMMENDATIONS.
PA-3) USE SCANNING EQUIPMENT OR OTHER MEANS TO LOCATE AND AVOID
CUTTING OR DAMAGING REINFORCING BARS. SER APPROVAL IS REQUIRED
PRIOR TO CUTTING OR DAMAGING REINFORCING.
PA-4) SPECIAL INSPECTION IS REQUIRED FOR ALL POST-INSTALLED ANCHOR
INSTALLATIONS, UON.C.Hnom IS MEASURED FROM FACE OF CONCRETE SUBSTRATE TO THE END OF THE
BOLT.
D.CONTRACTOR SHALL PROVIDE ANCHORS WITH SUFFICIENT TOTAL LENGTH FOR THE
SPECIFIED EMBEDMENT LENGTH, THICKNESS OF FASTENED PART, WASHER AND NUT.
PA-7) EXPANSION ANCHORS IN MASONRY
A.EXPANSION ANCHORS SHALL BE EITHER ONE OF THE FOLLOWING, UON:
HILTI KWIK BOLT 3
(ICC-ES REPORT ESR-1385)
SIMPSON WEDGE-ALL
(ICC-ES REPORT ESR-1396)
USE OF ZINC-PLATED CARBON STEEL EXPANSION ANCHORS IS LIMITED TO DRY,
INTERIOR LOCATIONS. USE MECHANICALLY GALVANIZED EXPANSION ANCHORS AT
EXTERIOR, WEATHER-EXPOSED, OR DAMP LOCATIONS.
B.ANCHOR EMBEDMENTS BELOW ARE TO BE USED WHEN EXPLICITLY SPECIFIED IN
THE STRUCTURAL DRAWINGS. FOR LOCATIONS WHERE TENSION TEST VALUES ARE NOT
SPECIFIED IN THE DRAWINGS, CONSULT WITH THE SER.
2 5/8"
3 1/2"
4 3/8"
30
35
55
HILTI KWIK BOLT 3 IN MASONRY
TORQUE TEST
2"
DIAMETER VALUE (FT-LBS)
2 1/2"
3 1/2"
4"
4
15
25
65
Hnom
TORQUE TESTANCHOR
DIAMETER VALUE (FT-LBS)Hnom
SIMPSON WEDGE-ALL IN MASONRY
4 3/4"120
5 1/4" 120
Hnom
Hnom
4 1/2"3460
SIMPSON STRONG-BOLT 2 IN LIGHTWEIGHT CONCRETE
302"
3"
SIMPSON STRONG-BOLT 2 IN NORMAL-WEIGHT CONCRETE
5 3/8"
30
60
90
2"
3"
60
TORQUE TESTANCHOR
DIAMETER HOLE DEPTH VALUE (FT-LBS)
MINIMUM
TORQUE TESTANCHOR
DIAMETER HOLE DEPTH VALUE (FT-LBS)
MINIMUM
3/8"
3/8"
1/2"
5/8"
1/2"
3 5/8"905/8"
HILTI KWIK BOLT TZ IN LIGHTWEIGHT CONCRETE
2 5/8"25
40
60
2 5/8"
3 7/8"
HILTI KWIK BOLT TZ IN NORMAL-WEIGHT CONCRETE
TORQUE TEST
3/4"
3/8"
1/2"
5/8"
ANCHOR
DIAMETER HOLE DEPTH VALUE (FT-LBS)
2 5/8"
5 3/4"
25
40
60
110
2 5/8"
4 3/4"
MINIMUM
TORQUE TESTANCHOR
DIAMETER HOLE DEPTH VALUE (FT-LBS)
MINIMUM
3/8"
1/2"
5/8"
6" 1503/4"
4 3/8" 1503/4"
Hnom
2 5/16"
2 3/8"
4 7/16"
5 9/16"
2 5/16"
2 3/8"
3 9/16"
1 7/8"
2 3/4"
5 1/8"
5 3/4"
1 7/8"
2 3/4"
3 3/8"
4 1/8"
Hnom
Hnom
Hnom
HOLE DEPTH
MINIMUM
3"
3 3/4"
6"
4 1/2"
TENSION TEST
VALUE (LBS)HOLE DEPTH
MINIMUM
2 7/8"
2 3/4"
3 5/8"
3 3/8"
4 3/8"
HOLE DEPTH
MINIMUM
HOLE DEPTH
MINIMUM
3 1/8"
4"
5 1/8"
2 1/4"
2 7/8"
4"
4 5/8"
5 1/2"
6"
3/4"4 1/2" 1104 5/16"
3/8"
1/2"
5/8"
3/4"
3/8"
1/2"
5/8"
3/4"
1/4"
3/8"
1/2"
5/8"
3/4"
CJ CONCRETE CONSTRUCTION JOINTS
CJ-1) PROVIDE CONSTRUCTION JOINTS IN ACCORDANCE WITH ACI-318. SUBMIT
SHOP DRAWINGS SHOWING PROPOSED CONSTRUCTION JOINT LOCATIONS,
DETAILS AND THE PLACEMENT SEQUENCE FOR THE STRUCTURAL ENGINEER'S
APPROVAL PRIOR TO PROCEEDING WITH WORK.
CJ-2) NO HORIZONTAL CONSTRUCTION JOINTS WILL BE PERMITTED IN BEAMS,
UPTURNED BEAMS, WALLS AND SLABS UNLESS SPECIFICALLY SHOWN ON THE
DRAWINGS OR APPROVED IN WRITING BY THE DESIGN PROFESSIONALS PRIOR
TO CONSTRUCTION.
CJ-3) PLACE VERTICAL CONSTRUCTION JOINTS IN WALLS TO PROVIDE A 60 FT
MAXIMUM LENGTH OF CONCRETE PLACEMENT AND LOCATE AS FOLLOWS:
A. FOUNDATION WALLS: MINIMUM OF 8 FT FROM ANY COLUMN LINE OR WALL
OPENING
B. GRADE BEAMS SUPPORTING FOUNDATION WALLS: AT CENTERLINES BETWEEN
SUPPORTS
C. RETAINING WALLS: 60 FT MAXIMUM LENGTH OF CONCRETE PLACEMENT
CJ-4) PROVIDE CONTINUOUS WATERSTOPS AT ALL CONSTRUCTION JOINTS
EXPOSED TO SOIL OR WATER, AS DESCRIBED IN THE SPECIFICATIONS.
MA MASONRY
MA-1) LOAD BEARING AND BACKUP WALL CONCRETE MASONRY CONSTRUCTION SHALL
CONFORM TO THE FOLLOWING MATERIAL STANDARDS:
CONCRETE BLOCK: ASTM C9O, NORMAL WEIGHT - TYPE I
MORTAR: ASTM C270, TYPE S OR M PORTLAND CEMENT / LIME ONLY
(USE TYPE M MORTAR WHEN MASONRY IS IN DIRECT
CONTACT WITH SOIL; TYPE S IN ALL OTHER CONDITIONS)
GROUT: ASTM C476 (MINIMUM 28 DAY COMPRESSIVE STRENGTH OF
2500 PSI)
REINFORCEMENT: ASTM A615, GRADE 60
JOINT REINFORCEMENT: ASTM A82, TRUSS OR LADDER TYPE
EXTERIOR JT REINF: GALVANIZE PER ASTM A153
INTERIOR JT REINF: GALVANIZE PER ASTM A641
M2-) THE MINIMUM COMPRESSIVE STRENGTH OF THE MASONRY (F' M) SHALL BE 3,000 PSI,
UON, AS DETERMINED IN ACCORDANCE WITH THE ABOVE REFERENCED SPECIFICATIONS
FOR MASONRY STRUCTURES.
MA-3) PLACE MASONRY UNITS WITH FULL FACESHELL MORTAR COVERAGE ON
HORIZONTAL AND VERTICAL FACE SHELLS. WEBS SHALL ALSO HAVE FULL MORTAR
COVERAGE AROUND ALL GROUTED CELLS.
MA-4) LAY MASONRY UNITS IN RUNNING BOND UON.
MA-5) ALL MASONRY SHALL INCLUDE REINFORCEMENT. IF REINFORCEMENT IS NOT
SPECIFICALLY INDICATED ON THE DRAWINGS, VERIFY WITH THE STRUCTURAL ENGINEER.
MA-6) CALCIUM CHLORIDE SHALL NOT BE USED IN MORTAR OR GROUT.
MA-7) ALL CELLS SHALL BE FULLY GROUTED.
PA-8) SCREW ANCHORS
A.SCREW ANCHORS SHALL BE EITHER ONE OF THE FOLLOWING, UON:
SIMPSON TITEN HD (ICC-ES REPORT ESR-2713)
HILTI KWIK HUS-EZ (ICC-ES REPORT ESR-3027)
B.ANCHOR EMBEDMENTS AND TENSION TEST VALUES BELOW ARE TO BE USED
WHEN EXPLICITLY SPECIFIED IN THE STRUCTURAL DRAWINGS. FOR LOCATIONS
WHERE TENSION TEST VALUES ARE NOT SPECIFIED IN THE DRAWINGS,
CONSULT WITH THE SER.
PA-5) FIELD TESTING OF POST-INSTALLED ANCHORS IS REQUIRED, UON. TEST
INSTALLED ANCHORS IN ACCORDANCE WITH THE FOLLOWING:
A.TEST 100% OF ANCHORS AT ALL STRUCTURAL APPLICATIONS, UON.
B.TEST 50% OF ANCHORS AT ALL NON-STRUCTURAL APPLICATIONS (SUCH
AS EQUIPMENT ANCHORAGE), UON.
C.TEST 10% OF ANCHORS AT SILL PLATE BOLTING APPLICATIONS, UON.
D.IF ANY ANCHOR FAILS TESTING, TEST ALL ANCHORS OF THE SAME TYPE
NOT PREVIOUSLY TESTED UNTIL 20 CONSECUTIVE ANCHORS PASS.
E.FIELD TESTS SHALL BE EITHER TENSION TESTS OR TORQUE TESTS, AS
REQUIRED FOR THE SPECIFIC ANCHOR TYPE.
F.TENSION TESTS: APPLY TEST LOADS TO ANCHORS WITHOUT REMOVING
THE NUT IF POSSIBLE. IF NOT, REMOVE NUT AND INSTALL A THREADED
COUPLER TO THE SAME TIGHTNESS AS THE ORIGINAL NUT USING A
TORQUE WRENCH. REACTION LOADS FROM TEST FIXTURES MAY BE
APPLIED CLOSE TO THE ANCHOR BEING TESTED, PROVIDED THE ANCHOR
IS NOT RESTRAINED FROM WITHDRAWING BY THE FIXTURES. TO BE
ACCEPTABLE, ANCHORS SHALL HAVE NO OBSERVABLE MOVEMENT AT THE
APPLICABLE TEST LOAD (OBSERVABLE MOVEMENT IS DEFINED
AS THE WASHER UNDER THE NUT BECOMING LOOSE).
G.TORQUE TESTS: TO BE ACCEPTABLE, THE APPLICABLE TEST TORQUE
MUST BE REACHED WITHIN ONE-HALF TURN OF THE NUT.
H.TEST EQUIPMENT IS TO BE CALIBRATED BY AN APPROVED TESTING
LABORATORY IN ACCORDANCE WITH STANDARD RECOGNIZED
PROCEDURES.
I.FIELD TESTING SHALL BE DONE IN THE PRESENCE OF THE PROJECT
INSPECTOR.
J.TESTING SHOULD OCCUR A MINIMUM OF 24 HOURS AFTER INSTALLATION
OF THE SUBJECT ANCHOR.
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
GENERAL NOTES II
S0.03
TT
01.17.2018
SU SUBMITTALS
SU-1) [TWENTY] WORKING DAYS PRIOR TO SUBMITTING SHOP DRAWINGS, THE
CONTRACTOR SHALL SUBMIT FOR STRUCTURAL ENGINEER' S REVIEW A SCHEDULE
WHICH DETAILS THE ESTIMATED QUANTITY OF SHOP DRAWINGS AND THE DATE THE
SHOP DRAWINGS WILL BE RECEIVED BY THE STRUCTURAL ENGINEER. THE
STRUCTURAL ENGINEER SHALL HAVE THE OPPORTUNITY TO REVIEW THE PROPOSED
SCHEDULE AND SUBMIT COMMENTS TO THE CONTRACTOR. THE FINAL SHOP DRAWING
SCHEDULE SHALL BE DEVELOPED AND SUBMITTED TO THE STRUCTURAL ENGINEER. IN
ACCORDANCE WITH THE SHOP DRAWING SCHEDULE, THE STRUCTURAL ENGINEER
WILL RETURN THE SHOP DRAWING ITEMS WITHIN TEN WORKING DAYS AFTER HAVING
RECEIVED THE REPRODUCIBLE SHOP DRAWING.
SU-2) THE CONTRACTOR IS TO REVIEW EACH SUBMITTAL PRIOR TO FORWARDING TO
ARCHITECT AND STRUCTURAL ENGINEER. THE CONTRACTOR IS TO STAMP EACH
SUBMITTAL VERIFYING THAT THE FOLLOWING IS ADDRESSED:
1.THE SHOP DRAWING IS REQUESTED.
2.THE SHOP DRAWING IS BASED ON THE LATEST DESIGN.
3.THE ARCHITECT' S AND STRUCTURAL ENGINEER' S COMMENTS FROM ANY
PREVIOUS SUBMITTALS ARE ADDRESSED.
4.THE WORK IS COORDINATED AMONG ALL CONSTRUCTION TRADES.
5.REVISIONS FROM PREVIOUS SUBMITTALS ARE CLEARLY MARKED BY CIRCLING OR
CLOUDS.
6.SUBMITTAL IS COMPLETE.
7. SUBMITTAL DOES NOT INCLUDE SUBSTITUTION REQUEST
8.SUBMITTAL SHALL INCLUDE A STAMP INDICATING PROJECT NAME AND
LOCATION, SUBMITTAL NUMBER, SPECIFICATION SECTION NUMBER.
THE STRUCTURAL ENGINEER SHALL RETURN, WITHOUT COMMENT, SUBMITTALS WHICH
THE CONTRACTOR HAS NOT STAMPED OR WHICH DO NOT MEET THE ABOVE
REQUIREMENTS. THE STRUCTURAL ENGINEER' S REVIEW OF SUBMITTALS SHALL BE
FOR GENERAL CONFORMANCE WITH THE DESIGN INTENT. NO WORK SHALL BE
STARTED WITHOUT SUCH REVIEW.
SU-3) FOR COMPONENTS THAT REQUIRE ENGINEERING BY THE CONTRACTOR, PROVIDE
A NOTE ON EACH SHOP DRAWING, WRITTEN AND SIGNED BY THE SUPPLIER' S
ENGINEER, INDICATING THAT THE SHOP DRAWING IS IN CONFORMANCE WITH THE
CALCULATIONS OF THE CONTRACTOR' S ENGINEER.
SU-4) THE FOLLOWING ITEMS REQUIRE SUBMITTALS FOR STRUCTURAL REVIEW AS
OUTLINED IN THE SPECIFICATIONS:
03 10 00 S CALC CONCRETE FORMWORK
03 20 00 S CONCRETE REINFORCING LAYOUT
03 30 00 S CONCRETE MIX DESIGNS
03 30 00 S CONCRETE CONSTRUCTION JOINT LAYOUT
04 10 00 S MASONRY REINFORCEMENT LAYOUT
04 10 00 S GROUT MIX DESIGNS
05 10 00 S STRUCTURAL STEEL
05 10 00 S CALC STRUCTURAL STEEL CONNECTION
05 30 00 S CALC STEEL FLOOR DECK
05 30 00 S CALC STEEL ROOF DECK
AC ARCHITECTURAL CLADDING
AC-1) TYPICAL DETAILS INDICATE GENERAL REQUIREMENT FOR ASSUMED
CONNECTIONS OF ARCHITECTURAL CLADDING TO BASE BUILDING STRUCTURES.
PROVIDE DESIGNS THAT MEET INDICATED CRITERIA AND CONFORM TO LISTED
CODES AND STANDARDS. REFER TO SUBMITTALS SECTION IN THESE GENERAL
NOTES FOR ADDITIONAL REQUIREMENTS.
SU-5) THE FOLLOWING SHOP DRAWINGS SHALL SHOW THE MAGNITUDES, DIRECTIONS,
LOCATIONS AND CONNECTION CONDITIONS OF ALL LOADS IMPOSED ON THE
ARCHITECTURAL ORNAMENTATION (FLAGPOLES, BANNERS,MASTS, ETC.)
ELEVATOR REACTIONS
SKYLIGHTS
IN ADDITION TO THE SHOP DRAWING REQUIREMENTS ABOVE, THE FOLLOWING
SUBMITTALS SHALL ALSO LIST THE DESIGN LOADS USED AND BE SIGNED AND SEALED
BY A LICENSED PROFESSIONAL ENGINEER IN THE STATE IN WHICH THE PROJECT IS
LOCATED:
COLD-FORMED METAL FRAMING
EXTERIOR CLADDING SYSTEMS
SU-6) DEFERRED SUBMITTALS SHALL FIRST BE SUBMITTED TO THE PROJECT
ARCHITECT AND/OR THE ENGINEER OF RECORD FOR REVIEW AND COORDINATION.
FOLLOWING THE COMPLETION OF THE ARCHITECT'S OR ENGINEER'S REVIEW, A
SUBMITTAL TO THE PLAN CHECK AUTHORITY SHALL BE MADE FOR REVIEW AND
APPROVAL. THIS SUBMITTAL SHALL BE PROCESSED IN ACCORDANCE WITH CBC
APPENDIX CHAPTER 1, SECTION 106.3.4.2. FOR A LIST OF DEFERRED ITEMS, SEE
ARCHITECTURAL DRAWINGS.
S = SHOP DRAWINGS AND/OR PRODUCT DATA REQUIRED
CALC = SUPPORTING CALCULATIONS REQUIRED, SIGNED AND SEALED BY A
LICENSED [PROFESSIONAL, STRUCTURAL] ENGINEER IN THE STATE IN WHICH THE
PROJECT IS LOCATED.
THE ITEMS IN THIS SECTION REQUIRE SHOP DRAWINGS, SUBMITTED FOR REVIEW
OF INTERACTION WITH THE BASE BUILDING STRUCTURE.
SS STRUCTURAL STEEL
SS-1)STEEL MATERIALS SHALL CONFORM TO THE FOLLOWING MINIMUM REQUIREMENTS UNLESS
OTHERWISE NOTED ON THE CONTRACT DOCUMENTS:
ROLLED SHAPES CHANNELS AND JOISTS: ASTM A572 OR A992, MIN. YIELD STRENGTH 50 KSI
MISCELLANEOUS ANGLES: ASTM A36
HOLLOW STRUCTURAL SECTIONS: ASTM A500 GRADE B, MIN YIELD STRENGTH 46 KSI FOR
RECTANGULAR HSS.
BASE PLATES A572, MIN YIELD STRENGTH 50 KSI
SS-2)CONNECTION MATERIAL SHALL CONFORM TO THE FOLLOWING MINIMUM REQUIREMENTS OR AS
NEEDED FOR CONNECTION DESIGN:
ANGLES: ASTM A36
WTs:ASTM A992
PLATES:ASTM A36, MIN YIELD STRENGTH 36 KSI OR
ASTM A572, MINIMUM YIELD STRENGTH 50 KSI
BOLTS:ASTM A325
NUTS:ASTM A563
WASHERS:ASTM F436
ANCHOR RODS:ASTM F1554 GRADE 55 WITH WELDABILITY SUPPLEMENT S1
HEADED STUDS ASTM A 108,GRADE 1010 THROUGH 1020 HEADED STUD TYPE,
COLD-FINISHEDCARBON STEEL, AWS D1.1, TYPE B. ¾”Ø UON
WELD ELECTRODES:E70XX
SS-3)WHERE NO CAMBER IS INDICATED, FABRICATE BEAMS SO THAT ANY NATURAL CAMBER IS UPWARD
AFTER ERECTION.
SS-4)SPLICES SHALL BE ALLOWED ONLY AT LOCATIONS SPECIFICALLY INDICATED ON THE STRUCTURAL
DRAWINGS UNLESS APPROVED OTHERWISE BY THE SER IN WRITING.
SS-5)FOR STEEL MEMBERS AND EMBEDMENTS EXPOSED TO WEATHER, PROVIDE HOT-DIPPED
GALVANIZED FINISH OR APPROVED ZINC RICH EXTERIOR COATING SYSTEM.
SS-6)FIELD MODIFICATION OF STRUCTURAL STEEL IS PROHIBITED WITHOUT PRIOR WRITTEN APPROVAL
OF THE DESIGN PROFESSIONALS.
SC STRUCTURAL STEEL CONNECTIONS
SC-1)ALL STEEL DETAILS AND CONNECTIONS SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS
OF "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS”, AISC-LOAD AND RESISTANCE
FACTOR DESIGN.
SC-2)ALL CONNECTIONS, UNLESS INDICATED AS BEING COMPLETELY DESIGNED ON THE
STRUCTURAL DRAWINGS, SHALL BE
DESIGNED AND DETAILED BY A [PROFESSIONAL/STRUCTURAL] ENGINEER LICENSED IN THE
STATE WHERE THE PROJECT IS LOCATED. THE DESIGN AND DETAILING SHALL COMPLY WITH
ALL APPLICABLE CODES AND SPECIFICATION SECTIONS.
SC-3)UNLESS OTHERWISE NOTED, DETAILS INDICATED ON DRAWINGS INDICATE GENERAL CRITERIA
FOR DESIGN AND DETAILING OF CONNECTIONS. DETAILS INDICATED ON DRAWINGS ARE NOT
INTENDED TO CONVEY COMPLETE CONNECTOR SIZES, PLATE SIZES, WELD SIZES, NUMBER OF
BOLTS, OR ANY OTHER SPECIFIC INFORMATION THAT IS OBTAINED THROUGH DESIGNING OF
AN INDIVIDUAL CONNECTION FOR A GIVEN SET OF LOADS. THESE DETAILS DO NOT SHOW
ERECTION AIDS. PROVIDE ERECTION AIDS AS REQUIRED AND REMOVE THEM AFTER WORK IS
COMPLETE.
SC-4)SUBMIT CONNECTIONS NOT SPECIFICALLY DETAILED ON THE DRAWINGS TO THE SER FOR
REVIEW PRIOR TO REVIEW OF SHOP DRAWINGS. FOR BIDDING PURPOSES, WHERE NO
MOMENT IS INDICATED ON DRAWINGS PROVIDE FULL MOMENT CAPACITY OF MEMBER (.9 Fy Z)
AND WHERE NO VERTICAL SHEAR IS INDICATED ON DRAWINGS PROVIDE FULL SHEAR
CAPACITY (.54 Fy d tw).
SC-5) ALTERNATE CONNECTIONS TO THOSE SHOWN ON DRAWINGS WILL ONLY BE CONSIDERED
ACCEPTABLE IF CONTRACTOR FORMALLY SUBMITS ALTERNATES AND THE SER APPROVES THE
SUBMITTAL.
SC-6)FOR CONNECTION DESIGN AND DETAILING, SET CONNECTION WORK POINT AT INTERSECTION
OF MEMBER CENTERLINES, UON.
SC-7)DESIGN ALL CONNECTIONS FOR FORCES INDICATED ON THE DRAWINGS. CONNECTION DESIGN
FORCES INDICATED ON THE DRAWINGS ARE FACTORED UON.
SC-8)USE NO MORE THAN TWO BOLT DIAMETERS, ALL BOLTS OF THE SAME DIAMETER SHALL BE OF
THE SAME GRADE, SKIP ONE SIZE BETWEEN DIAMETERS. BOLTS TO BE A MINIMUM OF 3/4-INCH
DIAMETER GRADE A325 OR AS COORDINATED WITH COMPLETELY DESIGNED CONNECTIONS.
SC-9) BEAM CONNECTION DESIGN NOTES SEE PLANS AND ELEVATIONS FOR BEAM REACTIONS AND
MOMENTS THAT ARE LARGER THAN THE VALUE SHOWN IN SCHEDULES.
DEVELOP THE LARGER OF THE BEAM SHEAR REACTION SCHEDULED, SHOWN ON PLANS OR
SHOWN ON ELEVATIONS. DEVELOP THE LARGER OF THE MOMENT SCHEDULED, SHOWN ON
PLANS OR SHOWN ON ELEVATIONS. DEVELOP THE LARGER OF THE AXIAL FORCE DENOTED AS
TF SHOWN ON PLANS OR SHOWN ON ELEVATIONS. SEE STEEL BEAM LEGEND.
ALL BEAM REACTIONS, AXIAL FORCES AND MOMENTS SHOWN ACT CONCURRENTLY. UON,
BEAM REACTIONS ACT IN GRAVITY DIRECTION WHILE AXIAL FORCES AND MOMENTS ARE TO BE
CONSIDERED REVERSIBLE. EXCEPT WHERE “SNUG TIGHT” INSTALLATION IS SPECIFICALLY
PERMITTED ON DRAWINGS OR “SLIP CRITICAL” DETAILING IS REQUIRED, ALL HIGH STRENGTH
BOLTS SHALL BE INSTALLED AS FULL PRETENSIONED BOLTS. AT A MINIMUM ALL BOLTED
MOMENT AND AXIAL CONNECTION SHALL HAVE PRETENSIONED BOLTS IN STANDARD HOLES.
BOLTED MOMENT CONNECTIONS AT CANTILEVERS AND BACKSPANS SHALL USE SLIP CRITICAL
BOLTS. DO NOT USE OVERSIZED OR SLOTTED HOLES FOR ANY CONNECTIONS UNLESS
SPECIFICALLY INDICATED ON THE DRAWINGS OR APPROVED IN WRITING BY THE SER.
SC-10)ALL WELDING SHALL CONFORM TO THE REQUIREMENTS OF THE STRUCTURAL WELDING CODE,
ANSI/AWS D1.1, LATEST EDITION. ALL WELD SIZES SHALL BE THE LARGER OF THE SIZE
REQUIRED BY CONNECTION FORCES, THE MINIMUM SIZE PER ANSI/AWS D1.1, OR 3/16 INCH
MINIMUM FILLET WELD UON. ANY WELD SIZES SHOWN ON THE DESIGN DRAWINGS ARE
CONSIDERED EFFECTIVE WELD SIZES AND SHALL BE INCREASED IN ACCORDANCE WITH AWS
AS REQUIRED BY GAPS OR SKEWS BETWEEN COMPONENTS.
SC-11)DESIGN, DETAIL, FURNISH AND INSTALL STIFFENERS, CONTINUITY PLATES, DOUBLER PLATES,
OR OTHER NECESSARY ADDITIONAL LOCAL STRENGTHENING MEASURES AS REQUIRED.
MEMBER SIZES INDICATED ON THE DRAWINGS ARE BASED ON MEMBER BEHAVIOR AWAY FROM
CONNECTIONS.
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
GENERAL NOTES III
S0.04
TT
01.17.2018
1
2.2
3
4
5
2
2.5
2.6
3.2
3.5
4.3
4.2
4.5
A
A
C
C
D
D
F
F
E
B
6' - 1"1' - 3"6' - 1"3' - 3"4' - 10 1/2"6' - 1"3' - 3"2' - 5 1/2"4' - 10 1/2"6' - 2 1/2"9"5' - 4"3' - 9"18' - 5" 4' - 10 1/2"22' - 2"
4.9
9' - 7 1/2" 9' - 4"
1
S2.01
2
S2.01
3
S2.01
1
S2.02
2
S2.02
2
S2.03
-5'-0"-5'-0"-5'-0"-5'-0"
3' - 2 1/2"3"3"7' - 10"3"1' - 9"BOW732TOW737.5
EG737 EG736
EG734.5
EG734.5EG738
TOW738.5
EG734.5EG739
TOW739.5
EG740
TOW740.5
EG734.5
EG741
TOW741.5
BOW732 TOW740.5
EG740
EG740
TOW741.5
EG741
EG735
TOW743
EG742.5
TOW744
EG743.5
TOW744
EG744
EG735
BOW732
TOF732
BOW733.5
EG736
EG735
4' - 7"TOF733.5
EG737 EG738 EG739
TOW742.3TOW738TOW737.5
EG736
1
S2.03
1
S3.01
SW4
SW2SW1SW7 SW1ATOW736.5
TOW74.5
EG742
SW1AEG735 SW6SW5SW4SW3A*5' - 6"
EG744
SW3A*GB GB
GB 3"3"IJ
IJ
1
S4.01
T/SOG EL: +734'-6"
LGP
LGP
LGP
LGPSW3SW8*SW8
8' - 11"
-7'-0"
SUMP
PIT
STEP IN FTG
2
S3.01
LGP 4' - 7" 3' - 6" 3' - 0"
SW8
40" DIA. X 6' DEEP SUMP
PIT SEE MEP DWG4' - 0"SW9*
2
S3.02
3
S3.01
GB1
S3.02
3
S3.02
4
S2.13
F3.5
F3F3
2' - 0"
3
S2.03
7' - 6 3/4"
7' - 1 3/4"1' - 7"1' - 3"2' - 0"
4
S2.03
4
S2.02
GB
LGP
LGP
LGP
LGP
TYP
F3
F34
S2.13
SIM [-2'-6"]
[-2'-6"]
4
S2.13
SIMW1 [-4'-6"]
PA*PA
PA
PA
PA
PA
PA
PA
PA PA
18"X18" PIER
SEE /1 S2.14
GB
GBGBGB1'-0".GBGBSEE ARCH DWG FOR
GUARD RAIL EMBED
SEE ARCH DWG FOR
GUARD RAIL EMBED
FOUNDATION PLAN NOTES:
SW..INDICATES SITE RETAINING WALLS. FOR WALL AND
FOUNDATIONS INFORMATION, SEE AND /1 S2.12 /5 S2.12
TOW..INDICATES TOP OF WALL AND BOTTOM OF WALL ELEVATION
BOW..IN FEET RESPECTIVELY.
EG..INDICATES APPROXIMATE EXTERIOR FINISHED GRADE IN FEET.
1. TOP OF WALL FOOTING IS AT BOTTOM OF WALL TYP UON.
2. VERIFY LOCATION OF UNDERGROUND UTILITIES BEFORE
EXCAVATIONS. NOTIFY THE ARCHITECT PRIOR TO EXCAVATION
IN THE EVENT SUCH UTILITIES ARE ENCOUNTERED.
3. CONTRACTOR SHALL COORDINATE ALL UTILITY PENETRATIONS
THROUGH FOOTINGS, CONCRETE WALLS, AND SLABS WITH
DETAILS ON S2 SERIES DRAWINGS.
4. FOR DRAINAGE DETAILS, SUMPS, PITS, DAMP PROOFING,
TRENCHES, CURBS, EXTERIOR WALKS, UTILITIES, EQUIPMENT
DETAILS, ETC., SEE DRAWINGS OTHER THAN STRUCTURAL.
5. SEE ARCH DWGS FOR EDGE OF SLAB LOCATIONS
6. TOP OF CONCRETE SLAB ELEVATION INDICATED ON THIS PLAN
IS FOR REFERENCE ONLY. COORDINATE WITH ARCH. DWGS.
FOR EXACT TOP OF SLAB ELEVATIONS, DEPRESSIONS, STEPS,
SLOPES, DRAINAGE, OPENINGS, ETC.
7.TOP OF ALL EXTERIOR FOUNDATIONS SHALL BE AT LEAST 2'-6"
BELOW GRADE LEVEL TO PROTECT AGAINST FROST. TYP. UON.
8.TOP OF ALL INTERIOR FOUNDATIONS SHALL BE AT LEAST 1'-0"
BELOW TOP OF SOG. TYP. UON.
9.ALL FOUNDATION WORK SHALL BE PERFORMED UNDER THE
OBSERVATION OF LICENSED GEOTECHNICAL ENGINEER,
RETAINED BY THE OWNER.
10.CONTRACTOR SHALL BE RESOPNSIBLE TO PROTECT ALL
EXCAVATION SLOPES
11. PIPE OR CONDUIT PLACED IN SLAB ON GRADE SHALL NOT BE
SPACED CLOSER THAN 3X THEIR DIAMETER ON CENTER. NO
PIPE OR CONDUITS SHALL BE PLACED IN THE SLAB ON GRADE
WITHIN 12 INCHES OF ANY COLUMN FACE.
16. REFER TO S6 SERIES FOR CMU WALL REINFORCEMENT
17.REFER TO FOR BASEPLATE INFORMATION
18.FOR ADDITIONAL INFORMATION REFER TO THE FOLLOWING
DWGS:
DRAWING LIST AND GEN NOTES S0 SERIES DWGS
PLANS S1 SERIES DWGS
FOUNDATION DETAILS S2 SERIES DWGS
ELEVATIONS S3 SERIES DWGS
CONCRETE SECTIONS AND DETAILS S4 SERIES DWGS
STEEL SECTIONS AND DETAILS S5 SERIES DWGS
19.LEGEND
S.O.G.:DENOTES 5" THICK NORMAL WEIGHT
CONCRETE SLAB ON GRADE REINFORCED WITH
TOP LAYER OF WWF 6X6-W6XW6 REFER TO
TYPICAL SLAB ON GRADE DETAILS ON SHEET S2.11
F...[ ]INDICATES FOOTING TYPE AND TOP OF FOOTING
ELEVATION. REFER TO S2 SERIES FOR SCHEDULE
INDICATES TYPICAL 8" CMU WALL REINFORCED WITH
#5 (VERT.) @ 16" OC. REFER TO TYPICAL CMU WALL
SCHEDULE FOR HORIXONTAL REINF. PROVIDE
BOND BEAM WITH 2#4 AT TOP AND BOTTOM OF CMU
WALL AND AT ROOF LEVEL WITH ADDITIONAL BOND
BEAMS AT 4'-0" OC. MAX. SEE S6 SERIES FOR
LINTEL, JAMB, AND PIER INFORMATION
INDICATES STEP IN FOOTING. SEE DETAIL
WF1[ ] INDICATES CONTINUOUS WALL FOOTING 24"X18"
DEEP WITH 3 - #5 LONGITUDINAL BARS AND #5 BARS
@ 12" OC. IN THE SHORT DIRECTION.
GB INDICATES 24"X18" GRADE BEAM. TOP TO BE FLUSH
WITH WALL/COLUMN FOOTING AND CENTERED ON
HSS COLUMN WITH 8-#6 AND #4 TIES @ 12" OC. GB
REBAR TO BE CONTINUOUS THROUGH FOOTING TO
FAR SIDE DISCONTINUITY ENDS.
IJ INDICATES 1 1/2" ISOLATION JOINT. SEE ARCH DWG FOR FILLER
MATERIAL.
W1 INDICATES 12" SHEAR WALL WITH #5 AT 12" OC EW AND EF.
REFER TO SECTION FOR FOOTING ELEVATION, SIZE AND
REINFORCEMENT.
/1 S5.01
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
LOWER LEVEL PLAN
S1.00
TT
01.17.2018
1/4" = 1'-0"
LOWER LEVEL1
N
1
2.2
3
4
5
2
2.5
2.6
3.2
3.5
4.3
4.2
4.5
A C D F
E 19' - 7 1/2"14' - 2 1/2"16' - 8"7' - 4"6' - 1"1' - 3"6' - 1"3' - 3"4' - 10 1/2"6' - 1"3' - 3"6' - 2 1/2"9"5' - 4"3' - 9"18' - 5" 4' - 10 1/2"22' - 2"B
D1
D1
D24.92' - 5 1/2"4' - 10 1/2"1
S2.01
2
S2.01
3
S2.01
1
S2.02
2
S2.02
2
S2.03
PB
PB
1
S5.02
PA3"PA
PA
5' - 9"1
S2.03
1
S3.01
1
S4.01
P
LGP
LGP
T/FLOOR EL: +744'-6"8' - 4"2' - 2"
1' - 2 3/4"3' - 8"6
S2.01
LGP
P P
PPLGP
LGP
LGP
2
S3.01
10"
2
S3.02
3
S3.01
1
S3.02
3
S3.02
3
S5.01
TYP
LGP
LGP 4
S5.01
19' - 2 1/2"
TYPP4
P4-4"-4"-4"D5LGP
LGP
LGP
LGP
HSS WC2
S5.02P4HSS WCP1.5
V30
W10X26
V30
V25 W10X22 V35 V10 W10X22 V10
V10W8X18LOWV10PA*PA
P*P
P P
PA PA
2
S4.01
2
S5.02
LGP ABOVE
8' - 10 1/2"
FLOOR/ROOF DECK AND FRAMING SCHEDULE
SLAB MARK STEEL DECK CFMF NOTES
9/16" CORRUGATED MD 10" FRAMING @16"OCD1 TYP. FLOOR
9/16" CORRUGATED MD D2 CORRIDOR
1 /2" B DECK D3 ROOF
8" FRAMING @16"OC
8" FRAMING @16"OC
1 /2" B DECK D4 SHAFT ROOF6" FRAMING @16"OC
D5 ENTRY6" FRAMING @16"OC9/16" CORRUGATED MD
FLOOR PLAN NOTES:
1.SEE GENERAL NOTES ON S0 SERIES DRAWINGS.
2. NOMINAL FLOOR ELEVATION IS CALLED OUT ON PLAN.
3. TOP ELEVATION OF FRAMING IS AT -[0'-1 13/16"] RELATIVE TO NOMINAL FLOOR
ELEVATION. TYP. UON.
4. TOP ELEVATION OF CORRUGATED METAL DECK IS AT -[0'-1 1/4"] RELATIVE TO NOMINAL
FLOOR ELEVATION. TYP. UON.
5. DEPRESSIONS, CURBS, AND OPENINGS SHOWN ON THIS PLAN ARE NOT COMPLETE AS
TO NUMBER, SIZE, AND LOCATION. FOR COMPLETE INFORMATION, REFER TO
DRAWINGS OTHER THAN STRUCTURAL.
6.ALL BEARING WALLS ARE INTENDED TO BE LATERAL LOAD RESISTING WALL. FLOOR
DIAPHRAGM AND SHEAR WALL DESIGN SHALL BE COORDINATED. PROVIDE LOADS
IMPOSED AT JAMB OF SHEAR WALL TO E.O.R
7. ALL CONNECTIONS TO BE DESIGNED FOR A MINIMUM SHEAR LOAD OF 10K UON ON PLAN
8.LEGEND:
INDICATES CFMF 10" BOX DRAG BEAM BY OTHERS. WITH SERVICE AXIAL LOAD
(KIPS). TOP ELEVATION IS AT [-1 13/16"] TYP. UON.
INDICATES STEEL CANOPY OUTRIGGER SEE PART PLAN AND SECTION. TOP
ELEVATION IS AT [-1 13/16"] TYP. UON.
INDICATES LIGHT GAGE BOX POST BY OTHERS. PROVIDE REACTIONS TO
E.O.R.
P INDICATES STEEL HSS6X6X1/4 POST CONT THROUGH THIS LEVEL
PA INDICATES STEEL HSS6X6X1/4 POST ABOVE THIS LEVEL
PB INDICATES STEEL HSS6X6X1/4 POST BELOW THIS LEVEL
WHERE * OCCURS AFTER "P","PA", OR "PB", POST TO BE HSS6X6X1/2
LGP
INDICATES CFMF 10" BOX BEAM BY OTHERS. TOP ELEVATION IS AT [-1 13/16"]
TYP. UON.
P...
INDICATES STEEL FRAMING WITH SERVICE PASS THRU AXIAL LOAD (KIPS)
IMPOSED ON ADJACENT CFMF. TOP ELEVATION IS AT [-1 13/16"] TYP. UON.
INDICATES STEEL HSS WIND COLLECTOR OR WIND GIRT SEE ELEVATION
FOR SIZES AND LOCATIONS. HORIZ CONN FORCE 10K. TYP. UON.
P...P...
INDICATES STEEL FRAMING WHERE "V" REPRESENTS THE MAGNITUDE OF
FACTORED SHEAR LOAD (KIPS). TOP ELEVATION IS AT [-1 13/16"] TYP. UON.
HSS WC OR WG
V...V...NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
GROUND FLOOR FRAMING
PLAN
S1.01
TT
01.17.2018
1/4" = 1'-0"
LEVEL 1 FRAMING PLAN1
N
1
2.2
3
4
5
2
2.5
2.6
3.2
3.5
4.3
4.2
4.5
A
A
C
C
D
D F
E
B
19' - 7 1/2"14' - 2 1/2"16' - 8"7' - 4"6' - 1"1' - 3"6' - 1"3' - 3"4' - 10 1/2"6' - 1"3' - 3"2' - 5 1/2"4' - 10 1/2"6' - 2 1/2"9"5' - 4"3' - 9"18' - 5" 4' - 10 1/2"22' - 2"
D1
D1 D24.9
1
S2.01
2
S2.01
PB
PB
HSS10X6X5/16PB
PB
HSS6X6X1/4 WIND GIRT1
S3.01
BEARING
WALL BELOW
BEARING
WALL BELOWHSS10X6X5/16PB
S5.11
1
S5.11
1
2
S5.11
LGP
LGP
LGP
LGP
LGP
T/FLOOR EL: +754'-3"
D1D1
D2PP
PP3' - 8"1' - 2 3/4"8' - 4"2' - 2"
PB W10X26
T/STEEL EL: 754'-7 3/4"
LGP
LGP
2
S3.01
2
S3.02
3
S3.01
1
S3.02
3
S3.02
P3
LGP
LGP
LGP
LGP
HSS WCHSS WG HSS WCP4P4HSS WG
P4P44
S5.01 D5P2
P2P1.5P1.5HSS WCHSS WCHSS WG
P4P1.5 P44
S5.01
P*P
P*
P
P P
P P
LGP
8' - 10 1/2"
FLOOR PLAN NOTES:
1.SEE GENERAL NOTES ON S0 SERIES DRAWINGS.
2. NOMINAL FLOOR ELEVATION IS CALLED OUT ON PLAN.
3. TOP ELEVATION OF FRAMING IS AT -[0'-1 13/16"] RELATIVE TO NOMINAL FLOOR
ELEVATION. TYP. UON.
4. TOP ELEVATION OF CORRUGATED METAL DECK IS AT -[0'-1 1/4"] RELATIVE TO NOMINAL
FLOOR ELEVATION. TYP. UON.
5. DEPRESSIONS, CURBS, AND OPENINGS SHOWN ON THIS PLAN ARE NOT COMPLETE AS
TO NUMBER, SIZE, AND LOCATION. FOR COMPLETE INFORMATION, REFER TO
DRAWINGS OTHER THAN STRUCTURAL.
6.ALL BEARING WALLS ARE INTENDED TO BE LATERAL LOAD RESISTING WALL. FLOOR
DIAPHRAGM AND SHEAR WALL DESIGN SHALL BE COORDINATED. PROVIDE LOADS
IMPOSED AT JAMB OF SHEAR WALL TO E.O.R
7. ALL CONNECTIONS TO BE DESIGNED FOR A MINIMUM SHEAR LOAD OF 10K UON ON PLAN
8.LEGEND:
INDICATES CFMF 10" BOX DRAG BEAM BY OTHERS. WITH SERVICE AXIAL LOAD
(KIPS). TOP ELEVATION IS AT [-1 13/16"] TYP. UON.
INDICATES STEEL CANOPY OUTRIGGER SEE PART PLAN AND SECTION. TOP
ELEVATION IS AT [-1 13/16"] TYP. UON.
INDICATES LIGHT GAGE BOX POST BY OTHERS. PROVIDE REACTIONS TO
E.O.R.
P INDICATES STEEL HSS6X6X1/4 POST CONT THROUGH THIS LEVEL
PA INDICATES STEEL HSS6X6X1/4 POST ABOVE THIS LEVEL
PB INDICATES STEEL HSS6X6X1/4 POST BELOW THIS LEVEL
WHERE * OCCURS AFTER "P","PA", OR "PB", POST TO BE HSS6X6X1/2
LGP
INDICATES CFMF 10" BOX BEAM BY OTHERS. TOP ELEVATION IS AT [-1 13/16"]
TYP. UON.
P...
INDICATES STEEL FRAMING WITH SERVICE PASS THRU AXIAL LOAD (KIPS)
IMPOSED ON ADJACENT CFMF. TOP ELEVATION IS AT [-1 13/16"] TYP. UON.
INDICATES STEEL HSS WIND COLLECTOR OR WIND GIRT SEE ELEVATION
FOR SIZES AND LOCATIONS. HORIZ CONN FORCE 10K. TYP. UON.
P...P...
INDICATES STEEL FRAMING WHERE "V" REPRESENTS THE MAGNITUDE OF
FACTORED SHEAR LOAD (KIPS). TOP ELEVATION IS AT [-1 13/16"] TYP. UON.
HSS WC OR WG
V...V...
FLOOR/ROOF DECK AND FRAMING SCHEDULE
SLAB MARK STEEL DECK CFMF NOTES
9/16" CORRUGATED MD 10" FRAMING @16"OCD1 TYP. FLOOR
9/16" CORRUGATED MD D2 CORRIDOR
1 /2" B DECK D3 ROOF
8" FRAMING @16"OC
8" FRAMING @16"OC
1 /2" B DECK D4 SHAFT ROOF6" FRAMING @16"OC
D5 ENTRY6" FRAMING @16"OC9/16" CORRUGATED MD
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
LEVEL 2 FRAMING PLAN
S1.02
TT
01.17.2018
1/4" = 1'-0"
LEVEL 2 FRAMING PLAN1
N
1 1
2.2 2.2
3
4
5 5
2
2.5
2.5
2.6
3.2 3.2
3.5 3.5
4.3
4.2
4.2
4.5 4.5
A
A
C
C
D
D F
E
B
19' - 7 1/2"14' - 2 1/2"16' - 8"7' - 4"6' - 1"1' - 3"6' - 1"3' - 3"4' - 10 1/2"6' - 1"3' - 3"2' - 5 1/2"4' - 10 1/2"6' - 2 1/2"9"5' - 4"3' - 9"18' - 5" 4' - 10 1/2"22' - 2"
D1
D1
D24.9
PBPB
PB PB
1
S3.01
S5.12
1
2
S5.12
LGP
LGP
LGP
LGP
LGP
T/FLOOR EL: +764'-0"
D1D1
D28' - 4"2' - 2"
1' - 2 3/4"
BEARING WALL
BELOW
LGP
LGP
D3
T/STEEL EL: 758'-3 1/2"
2' - 11 1/2"
2
S3.01
2
S3.02
3
S3.01
1
S3.02 3
S3.02 D2LGP
LGP
LGP
LGP LGP
HSS WCHSS WG HSS WCP4P4HSS WCHSS WG
HSS WCP4P44
S5.01P1P1P4P3
P1.5 P44
S5.01
V15HSS10X4X5/16V15V15HSS10X4X5/16V15P*P
P*
P
P P
P P
LGP
8' - 10 1/2"
FLOOR PLAN NOTES:
1.SEE GENERAL NOTES ON S0 SERIES DRAWINGS.
2. NOMINAL FLOOR ELEVATION IS CALLED OUT ON PLAN.
3. TOP ELEVATION OF FRAMING IS AT -[0'-1 13/16"] RELATIVE TO NOMINAL FLOOR
ELEVATION. TYP. UON.
4. TOP ELEVATION OF CORRUGATED METAL DECK IS AT -[0'-1 1/4"] RELATIVE TO NOMINAL
FLOOR ELEVATION. TYP. UON.
5. DEPRESSIONS, CURBS, AND OPENINGS SHOWN ON THIS PLAN ARE NOT COMPLETE AS
TO NUMBER, SIZE, AND LOCATION. FOR COMPLETE INFORMATION, REFER TO
DRAWINGS OTHER THAN STRUCTURAL.
6.ALL BEARING WALLS ARE INTENDED TO BE LATERAL LOAD RESISTING WALL. FLOOR
DIAPHRAGM AND SHEAR WALL DESIGN SHALL BE COORDINATED. PROVIDE LOADS
IMPOSED AT JAMB OF SHEAR WALL TO E.O.R
7. ALL CONNECTIONS TO BE DESIGNED FOR A MINIMUM SHEAR LOAD OF 10K UON ON PLAN
8.LEGEND:
INDICATES CFMF 10" BOX DRAG BEAM BY OTHERS. WITH SERVICE AXIAL LOAD
(KIPS). TOP ELEVATION IS AT [-1 13/16"] TYP. UON.
INDICATES STEEL CANOPY OUTRIGGER SEE PART PLAN AND SECTION. TOP
ELEVATION IS AT [-1 13/16"] TYP. UON.
INDICATES LIGHT GAGE BOX POST BY OTHERS. PROVIDE REACTIONS TO
E.O.R.
P INDICATES STEEL HSS6X6X1/4 POST CONT THROUGH THIS LEVEL
PA INDICATES STEEL HSS6X6X1/4 POST ABOVE THIS LEVEL
PB INDICATES STEEL HSS6X6X1/4 POST BELOW THIS LEVEL
WHERE * OCCURS AFTER "P","PA", OR "PB", POST TO BE HSS6X6X1/2
LGP
INDICATES CFMF 10" BOX BEAM BY OTHERS. TOP ELEVATION IS AT [-1 13/16"]
TYP. UON.
P...
INDICATES STEEL FRAMING WITH SERVICE PASS THRU AXIAL LOAD (KIPS)
IMPOSED ON ADJACENT CFMF. TOP ELEVATION IS AT [-1 13/16"] TYP. UON.
INDICATES STEEL HSS WIND COLLECTOR OR WIND GIRT SEE ELEVATION
FOR SIZES AND LOCATIONS. HORIZ CONN FORCE 10K. TYP. UON.
P...P...
INDICATES STEEL FRAMING WHERE "V" REPRESENTS THE MAGNITUDE OF
FACTORED SHEAR LOAD (KIPS). TOP ELEVATION IS AT [-1 13/16"] TYP. UON.
HSS WC OR WG
V...V...
FLOOR/ROOF DECK AND FRAMING SCHEDULE
SLAB MARK STEEL DECK CFMF NOTES
9/16" CORRUGATED MD 10" FRAMING @16"OCD1 TYP. FLOOR
9/16" CORRUGATED MD D2 CORRIDOR
1 /2" B DECK D3 ROOF
8" FRAMING @16"OC
8" FRAMING @16"OC
1 /2" B DECK D4 SHAFT ROOF6" FRAMING @16"OC
D5 ENTRY6" FRAMING @16"OC9/16" CORRUGATED MD
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
LEVEL 3 FRAMING PLAN
S1.03
TT
01.17.2018
1/4" = 1'-0"
LEVEL3 FRAMING PLAN1
N
1 1
2.2 2.2
3
4
5 5
2
2.5
2.5
2.6
3.2 3.2
3.5 3.5
4.3
4.2
4.2
4.5 4.5
A
A
C
C
D
D F
E
B
19' - 7 1/2"14' - 2 1/2"16' - 8"7' - 4"6' - 1"1' - 3"6' - 1"3' - 3"4' - 10 1/2"6' - 1"3' - 3"2' - 5 1/2"4' - 10 1/2"6' - 2 1/2"9"5' - 4"3' - 9"18' - 5" 4' - 10 1/2"22' - 2"
D1
D1 D24.9 4.9
1
S3.01
LGP
LGP
LGP
LGP
LGP
T/FLOOR EL: +773'-9"
D1D1
D28' - 4"2' - 2"
1' - 2 3/4"
2
S3.0110"
2
S3.02
3
S3.01
1
S3.02 3
S3.02
LGP
LGP
LGP
LGP LGP
LGP
HSS WCHSS WG HSS WCP4P4HSS WCHSS WG
HSS WCP4P4P4P3
P1.5 P44
S5.01
4
S5.01
P*P
P*
P
P P
P P
LGP
8' - 10 1/2"
FLOOR/ROOF DECK AND FRAMING SCHEDULE
SLAB MARK STEEL DECK CFMF NOTES
9/16" CORRUGATED MD 10" FRAMING @16"OCD1 TYP. FLOOR
9/16" CORRUGATED MD D2 CORRIDOR
1 /2" B DECK D3 ROOF
8" FRAMING @16"OC
8" FRAMING @16"OC
1 /2" B DECK D4 SHAFT ROOF6" FRAMING @16"OC
D5 ENTRY6" FRAMING @16"OC9/16" CORRUGATED MD
FLOOR PLAN NOTES:
1.SEE GENERAL NOTES ON S0 SERIES DRAWINGS.
2. NOMINAL FLOOR ELEVATION IS CALLED OUT ON PLAN.
3. TOP ELEVATION OF FRAMING IS AT -[0'-1 13/16"] RELATIVE TO NOMINAL FLOOR
ELEVATION. TYP. UON.
4. TOP ELEVATION OF CORRUGATED METAL DECK IS AT -[0'-1 1/4"] RELATIVE TO NOMINAL
FLOOR ELEVATION. TYP. UON.
5. DEPRESSIONS, CURBS, AND OPENINGS SHOWN ON THIS PLAN ARE NOT COMPLETE AS
TO NUMBER, SIZE, AND LOCATION. FOR COMPLETE INFORMATION, REFER TO
DRAWINGS OTHER THAN STRUCTURAL.
6.ALL BEARING WALLS ARE INTENDED TO BE LATERAL LOAD RESISTING WALL. FLOOR
DIAPHRAGM AND SHEAR WALL DESIGN SHALL BE COORDINATED. PROVIDE LOADS
IMPOSED AT JAMB OF SHEAR WALL TO E.O.R
7. ALL CONNECTIONS TO BE DESIGNED FOR A MINIMUM SHEAR LOAD OF 10K UON ON PLAN
8.LEGEND:
INDICATES CFMF 10" BOX DRAG BEAM BY OTHERS. WITH SERVICE AXIAL LOAD
(KIPS). TOP ELEVATION IS AT [-1 13/16"] TYP. UON.
INDICATES STEEL CANOPY OUTRIGGER SEE PART PLAN AND SECTION. TOP
ELEVATION IS AT [-1 13/16"] TYP. UON.
INDICATES LIGHT GAGE BOX POST BY OTHERS. PROVIDE REACTIONS TO
E.O.R.
P INDICATES STEEL HSS6X6X1/4 POST CONT THROUGH THIS LEVEL
PA INDICATES STEEL HSS6X6X1/4 POST ABOVE THIS LEVEL
PB INDICATES STEEL HSS6X6X1/4 POST BELOW THIS LEVEL
WHERE * OCCURS AFTER "P","PA", OR "PB", POST TO BE HSS6X6X1/2
LGP
INDICATES CFMF 10" BOX BEAM BY OTHERS. TOP ELEVATION IS AT [-1 13/16"]
TYP. UON.
P...
INDICATES STEEL FRAMING WITH SERVICE PASS THRU AXIAL LOAD (KIPS)
IMPOSED ON ADJACENT CFMF. TOP ELEVATION IS AT [-1 13/16"] TYP. UON.
INDICATES STEEL HSS WIND COLLECTOR OR WIND GIRT SEE ELEVATION
FOR SIZES AND LOCATIONS. HORIZ CONN FORCE 10K. TYP. UON.
P...P...
INDICATES STEEL FRAMING WHERE "V" REPRESENTS THE MAGNITUDE OF
FACTORED SHEAR LOAD (KIPS). TOP ELEVATION IS AT [-1 13/16"] TYP. UON.
HSS WC OR WG
V...V...
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
LEVEL 4 FRAMING PLAN
S1.04
TT
01.17.2018
1/4" = 1'-0"
LEVEL 4 FRAMING PLAN1
N
A5.11
6
1 1
2.2 2.2
3
4
5 5
2
2.5
2.5
2.6
3.2 3.2
3.5 3.5
4.3
4.2
4.2
4.5 4.5
A
A
C
C
D
D F
E
B
19' - 7 1/2"14' - 2 1/2"16' - 8"7' - 4"6' - 1"1' - 3"6' - 1"3' - 3"4' - 10 1/2"6' - 1"3' - 3"2' - 5 1/2"4' - 10 1/2"6' - 2 1/2"9"5' - 4"3' - 9"18' - 5" 4' - 10 1/2"22' - 2"
D3
D3 D34.9 4.9
D3
D3
D31
S3.01
LGP
LGP
LGP
LGP
LGP LGP
T/ROOF DECK EL: +783'-3 3/4"
LGP
2
S3.0110"
2
S3.02
3
S3.01
1
S3.02
3
S3.02
RTU 1 RTU 2
RTU 3
RTU 4
PROVIDE ADDL
CFMF AS REQ'D
TYP
LGP
LGP
LGP
LGP
HSS WCHSS WG HSS WCP2P2HSS WCHSS WG
HSS WCP2P2P2P1.5
P1 P24
S5.01
4
S5.01
3
S5.11
PB*PB
PB*PB
PB PB
PB PB
LGP
8' - 10 1/2"
FLOOR/ROOF DECK AND FRAMING SCHEDULE
SLAB MARK STEEL DECK CFMF NOTES
9/16" CORRUGATED MD 10" FRAMING @16"OCD1 TYP. FLOOR
9/16" CORRUGATED MD D2 CORRIDOR
1 /2" B DECK D3 ROOF
8" FRAMING @16"OC
8" FRAMING @16"OC
1 /2" B DECK D4 SHAFT ROOF6" FRAMING @16"OC
D5 ENTRY6" FRAMING @16"OC9/16" CORRUGATED MD
FLOOR PLAN NOTES:
1.SEE GENERAL NOTES ON S0 SERIES DRAWINGS.
2. NOMINAL FLOOR ELEVATION IS CALLED OUT ON PLAN.
3. TOP ELEVATION OF FRAMING IS AT -[0'-1 1/2"] RELATIVE TO ROOF DECK
ELEVATION. TYP. UON.
4. DEPRESSIONS, CURBS, AND OPENINGS SHOWN ON THIS PLAN ARE NOT COMPLETE AS
TO NUMBER, SIZE, AND LOCATION. FOR COMPLETE INFORMATION, REFER TO
DRAWINGS OTHER THAN STRUCTURAL.
5. ALL CONNECTIONS TO BE DESIGNED FOR A MINIMUM SHEAR LOAD OF 10K UON ON PLAN
6.LEGEND:
INDICATES LIGHT GAGE BOX POST BY OTHERS
P INDICATES STEEL HSS6X6X1/4 POST CONT THROUGH THIS LEVEL
PA INDICATES STEEL HSS6X6X1/4 POST ABOVE THIS LEVEL
PB INDICATES STEEL HSS6X6X1/4 POST BELOW THIS LEVEL
WHERE * OCCURS AFTER "P","PA", OR "PB", POST TO BE HSS6X6X1/2
LGP
RTU 1 INDICATES 780LB (TOTAL WEIGHT) ROOF TOP UNIT. COORDINATE WITH ARCH
AND MEP DWGS.
RTU 2 INDICATES 700LB (TOTAL WEIGHT) ROOF TOP UNIT. COORDINATE WITH ARCH
AND MEP DWGS.
RTU 3 INDICATES 420LB (TOTAL WEIGHT) ROOF TOP UNIT. COORDINATE WITH ARCH
AND MEP DWGS.
RTU 4 INDICATES 400 LB (TOTAL WEIGHT) ROOF TOP UNIT. COORDINATE WITH ARCH
AND MEP DWGS.
INDICATES CFMF 10" BOX DRAG BEAM BY OTHERS. WITH SERVICE AXIAL LOAD
(KIPS).
INDICATES STEEL CANOPY OUTRIGGER SEE PART PLAN AND SECTION.
INDICATES CFMF 8" BOX BEAM BY OTHERS.
P...
INDICATES STEEL FRAMING WITH SERVICE PASS THRU AXIAL LOAD (KIPS)
IMPOSED ON ADJACENT CFMF.
INDICATES STEEL HSS WIND COLLECTOR OR WIND GIRT SEE ELEVATION
FOR SIZES AND LOCATIONS. HORIZ CONN FORCW 10K TYP. UON.
P...P...
INDICATES STEEL FRAMING WHERE "V" REPRESENTS THE MAGNITUDE OF
FACTORED SHEAR LOAD (KIPS).
HSS WC OR WG
INDICATES STEEL HSS4X4X5/16 SCREEN WALL POST AT 7'-0" OC MAX
TRIBUTARY WIDTH AND ADD'L SUPPORTING JOIST/BLOCKING
REQUIRED AT BASE FOR WIND IMPOSED LOADS. SEE /3 S5.11
V...V...
3
3.2
3.5
D
D4
T/ROOF DECK EL: +788'-7 1/2"
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
ROOF LEVEL FRAMING PLAN
S1.05
TT
01.17.2018
1/4" = 1'-0"
ROOF LEVEL FRAMING PLAN1
N
1/4" = 1'-0"
ELEVATOR SHAFT ROOF PLAN2
LOWER LEVEL
734' - 6"
5 4.3
GROUND FLOOR
744' - 6"
4.9
2' - 1" +/-+/-
1' - 1 1/4"
746' - 7"
740' - 8"
740' - 0"
LOW STRENGTH FLOWABLE FILL
AT 2' MAX LIFT EVERY 24 HOURS
PRIOR TO CFMF CONSTRUCTION
SHORING/SHEETING BY
OTHERS
EXISTING RETAINING WALL
BACK FILL PRIOR TO CFMF
CONSTRUCTION 5' - 0"#7H AT 12" OC IF
#7H AT 12" OC OF
#9H AT 12" OC IF
#7H AT 12" OC OF
18" CONC WALL
WITH #6V AT 12" EF
WALL FOOTING WITH 3#7 ES
AND 3 #5 LONGITUDINAL BARS
BOTTOM AND #5 SHORT BARS
AT 12" OC T&B
S2.01
4
LTS.MEP SUMP PIT SEE PLAN
LOW STRENGTH FLOWABLE FILL
AT 2' MAX LIFT EVERY 24 HOURS
PRIOR TO CFMF CONSTRUCTION
INSIDE
FACE (IF)
OUTSIDE
FACE (OF)
CFMF WALL BY
OTHERS
CFMF FLOOR BY
OTHERS
LOWER LEVEL
734' - 6"
5 4.5
GROUND FLOOR
744' - 6"
4.9
4' - 6"10"
8"
1' - 9 1/2"1' - 8"2 1/2"1' - 0"BACKFILL PRIOR TO CFMF
CONSTRUCTION
S2.01
5
LOWER LEVEL
734' - 6"
A
GROUND FLOOR
744' - 6"
EG VARIES SEE PLAN
IMPORTED BACKFILL
TYP5 1/2"TYP
8" CURB
1' - 6"GROUND FLOOR
744' - 6"
4.9
CFMF FRAMING SEE PLAN
8" CURB SEE PLAN
18" CONC. WALL
SEE PLAN AND
WALL SECTION
CFMF WALL BY
OTHERS SEE PLAN
5 4.9
3' - 3 1/2"1' - 8"RETAINING SEE PLAN AND
SCHEDULED
8" WALL WITH #5 AT 12" OC
EW AND EF
TRANSITION BEAM WITH #5
CLOSED STIRRUPS AT 12" OC
#5 BAR TYP TOTAL 8
#5 TIES AR 12" OC
F
GROUND FLOOR
744' - 6"
6" CFMF
B/STEEL TO ALIGN
WITH 10" CFMF
TYP AT ENTRY.
10" CFMF BOX BEAM2"S2.02
3
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
FOUNDATION WALL SECTIONS
I
S2.01
TT
01.17.2018
1/2" = 1'-0"
SECTION AT NORTH FOUNDATION WALL I1 1/2" = 1'-0"
SECTION AT NORTH FOUNDATION WALL II2 1/2" = 1'-0"
SECTION AT WEST WALL3
1 1/2" = 1'-0"
WALL SECTION AT GROUND FLOOR SLAB4 1 1/2" = 1'-0"
SECTION AT WALL5 1 1/2" = 1'-0"
SECTION AT ENTRY/SPLIT SLAB6
LOWER LEVEL
734' - 6"
F
GROUND FLOOR
744' - 6"
IMPORTED BACKFILL
PRIOR TO CFMF
CONSTRUCTION 1' - 0"S2.02
3
LOWER LEVEL
734' - 6"
F
GROUND FLOOR
744' - 6"
EG VARIES SEE PLAN
TOP OF BED ROCK
VARIES FROM 728 TO 722
732' - 0"
F
GROUND FLOOR
744' - 6"
CFMF FRAMING SEE PLAN
8" CURB SEE PLAN
10" CONC. WALL
SEE PLAN
CFMF WALL BY
OTHERS SEE PLAN
LOWER LEVEL
734' - 6"
44.34.54.9
GB SEE PLAN AND EXTEND
GB TO TOP OF SHEAR WALL
FTG WITH #5 AT 12" DOWELS
EW BOTTOM AND EF.
LTS TYP
12" SHEAR WALL SEE PLAN AND
SECTION FOR REINFORCEMENT
RETAINING WALL SEE PLAN 1' - 0"2' - 6"4' - 0"TOP OF SHEAR WALL
FTG SEE TYP DETAILS
FOR REBARS IN FTG
STEPS
CFMF WALL BY
OTHERS AND
FTG BEYOND
CFMF WALL
BY OTHERS
AND FTG
EXTEND RETAINING WALL FTG
TO FAR SIDE OF SHEAR WALL
FOOTING
2' - 2 1/2"1' - 8"3' - 0"2' - 0"NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
FOUNDATION WALL SECTIONS
II
S2.02
TT
01.17.2018
1/2" = 1'-0"
SECTION AT EAST WALL I1 1/2" = 1'-0"
SECTION AT EAST WALL II2
1 1/2" = 1'-0"
SECTION AT GROUND FLOOR SLAB3 1/2" = 1'-0"
SHEAR WALL ELEVATION4
LOWER LEVEL
734' - 6"
1 2
GROUND FLOOR
744' - 6"
EG VARIES SEE PLAN
IMPORTED BACKFILL PRIOR
TO CFMF CONSTRUCTION
TOP OF WALL VARIES SEE PLAN 1' - 0"LOWER LEVEL
734' - 6"
1
GROUND FLOOR
744' - 6"
TOP OF WALL VARIES SEE PLAN
IMPORTED BACKFILL
PRIOR TO CFMF
CONSTRUCTION
2 1/2"
EG VARIES SEE PLAN
1' - 0"LOWER LEVEL
734' - 6"
SHEAR WALL AND
FTG SEE PLAN
SUMP PIT SEE PLAN
THICKEN WALL
TO SUPPORT
SLAB
4"
TOP ELEVATION OF WALL
FOOTING VARIES SEE
WALL ELEVATION
#5 LONGITUDINAL BARS 4 BOTTOM
AND 2 TOP AND #5 HOOKED BARS IN
SHORT DIRECTION AT 12" OC T&B
3' - 0"2' - 0"LOWER LEVEL
734' - 6"
F
GB SEE PLAN AND
EXTEND GB TO TOP OF
SHEAR WALL FTG
WITH #5 AT 12"
DOWELS EW BOTTOM
AND EF.
CFMF WALL AND FTG
THICKENED AT SHEAR
WALL FTG
SHEAR WALL AND FTG HSS COLUMN ON FTG WITH
CONC PIER
RETAINING WALL AND FTG
LTS TYP
OR HOOK AT
FAR END
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
FOUNDATION WALL SECTIONS
III
S2.03
TT
01.17.2018
1/2" = 1'-0"
SECTION AT SOUTH WALL2 1/2" = 1'-0"
SECTION AT SOUTH WALL I1 1/2" = 1'-0"
SECTION AT SHEARA WALL3
1/2" = 1'-0"
SECTION AT SHEAR WALL4
TOOLED EDGES (1/8" RADIUS)
CONTINUOUS KEYWAY
AT MID-DEPTH OF SLAB
FORMED, SAWED, OR TOOLED JOINT.
SAWED JOINTS TO BE PERFORMED
BEFORE CONCRETE STARTS TO COOL
AND AS SOON AS CONCRETE
SURFACE
IS FIRM ENOUGH NOT TO BE TORN OR
DAMAGED BY THE BLADE
SLAB REINFORCEMENT
SEE PLAN
COMPACTED SUBGRADE
TYPICAL
SEE GEOTECHNICAL
ENGINEERING REPORT
VAPOR BARRIER
TYPICAL
SEE ARCHITECTURAL
DOCUMENTS
COMPACTED GRANULAR FILL TYPICAL
SEE GEOTECHNICAL
ENGINEERING REPORT
SEE ARCHITECTURAL DOCUMENTS
FOR SEALANT REQUIREMENTS
SEE ARCHITECTURAL
DOCUMENTS
FOR SEALANT REQUIREMENTS
CONTRACTION JOINT
SLAB ON GRADE
T/SLAB ON GRADE
EL SEE PLAN SEE PLANT SLAB THICKNESSCONSTRUCTION JOINT/CONTRACTION JOINT
TT/4TT/6 MIN
T/3NOTE:
1. WHERE NOT INDICATED ON DRAWINGS PROVIDE JOINTS AT COLUMN CENTERLINES AND
BETWEEN COLUMN CENTERLINES WITH SPACING OF JOINTS NOT TO EXCEED 36 TIMES
THE SLAB THICKNESS (T-INCHES)TYP 0"(2" MAX)T/3 CLEARSUPPORTS FOR
REINFORCEMENT
PER SPECIFICATIONS
1'-0" MIN
WWR LAP 2 PANELS
WHERE REINFORCEMENT BARS
ARE SHOWN PROVIDE LTS
REINFORCEMENT TO BE
INTERRUPTED AT JOINT
TOOLED EDGES
EQ EQ
APPLY BOND BREAKER
TO SLAB EDGE
X" DIAMOND PLATE
DOWEL SYSTEM @ Y" OC
DOWELED CONSTRUCTION JOINT (WHERE INDICATED ON PLAN)
SIDE OF CONSTRUCTION JOINT
2" CLEAR COVER AT EACH
1
1
T/PIT SLAB
EL SEE PLAN
1' - 0"
T/SUMP PIT SLAB
EL SEE PLAN
6"
SUMP PIT
VERIFY SIZE AND
LOCATION WITH
ELEVATOR
REQUIREMENTS
#6@12"
TOP AND BOTTOM
EACH WAY
6"1' - 0"T/SLAB ON GRADE
EL SEE PLAN
#4@12"
AT ALL SIDES
OF PIT
2'-6"2'-6"T#4
CONTINUOUS
1.5 T6"
T/PIT SLAB
EL SEE PLAN
SECTION AT SUMP PIT
COMPACTED
FILL TYPICAL
ROUGHEN TO 1/4"
AMPLITUDE TYPICAL1' - 0"12". SEE PLAN 12'.
#4@12" CONTINUOUS
EACH FACE
TYPICAL
#4@12" EACH
FACE TYPICAL
#6@12"
TOP AND BOTTOM
EACH WAY
.CLR1"CLR3"CLR
1"
CLR
2"TYP UON 3/4" CLR TO BARCMU ELEAVATOR SHAFT
WALL SEE PLAN
CFMF WALL SEE PLAN
PILASTER
CONSTRUCTION JOINT
OR CONTRACTION
JOINT
FOUNDATION WALL
RECTANGULAR OR
SQUARE COLUMN
CONSTRUCTION JOINT
OR CONTRACTION
JOINT
ISOLATION JOINT
WITH
2 LAYERS OF 30# FELT
ISOLATION JOINT
WITH
2 LAYERS OF 30# FELT
CONCRETE INFILL
BETWEEN COLUMN
AND ISOLATION
JOINT
CONCRETE INFILL
BETWEEN
PILASTER AND ISOLATION
JOINT
NOTES:
1. SEE TYPICAL SLAB ON GRADE DETAILS FOR JOINT SPACING REQUIREMENTS
2. CONCRETE INFILL BETWEEN COLUMN AND ISOLATION JOINT TO BE POURED AFTER ALL THE SLABS SUPPORTED BY THE COLUMN HAVE BEEN POURED
3. PROVIDE ADDITIONAL CLEARANCE AS REQUIRED TO ENSURE 3" MINIMUM CONCRETE COVER OVER BASE PLATE AND ANCHOR RODS BELOW.
PILASTER RECTANGULAR OR SQUARE COLUMNMIN3"MIN3"
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
TYPICAL SLAB ON GRADE
DETAILS
S2.11
TT
01.17.2018
NOT TO SCALE
TYPICAL SLAB ON GRADE DETAILS1
NOT TO SCALE
ELEVATOR PIT AT SLAB ON GRADE3
NOT TO SCALE
TYPICAL ISOLATION JOINT DETAILS AT SLAB ON GRADE2
HORIZONTAL
CONTINUOUS BARS
EACH FACE
SEE SCHEDULE
W2 BARS
SEE SCHEDULE
DOWEL BARS TO MATCH SIZE
AND SPACING OF W2 BARS
F1 TOP BARS
SEE SCHEDULE
CONTINUOUS BARS
SEE SCHEDULE
F2 BOTTOM BARS
SEE SCHEDULE
W1 BARS SEE SCHEDULE
DOWELS TO MATCH SIZE AND
SPACING OF W1 BARS
NOTES:
1. WALL DESIGNED FOR DRAINED CONDITION. SEE MECHANICAL AND/OR CIVIL DRAWINGS
2. DO NOT BACK FILL UNTIL WALL COMPRESSIVE STRENGTH f'c REACHES 28 DAY DESIGN STRENGTH
3. FOR RETAINING WALL EXPOSED TO VIEW PROVIDE VERTICAL CONTRACTION JOINTS AT 20'-0"
ON CENTER MAXIMUM (8'-0" MAXIMUM FROM CORNERS). COORDINATE WITH ARCHITECTURAL DRAWINGS
ISOLATION JOINT
T/WALL
EL SEE PLAN
T/SLAB (OR SOIL) ON GRADE
EL SEE PLAN
T/FOOTING
EL SEE PLAN
SCHEDULEA - SEE 0"
SEE PLAN
OR SCHEDULE
T
2" DIAMETER WEEP AT 10'-0" OC
MAX. NO WEEP HOLES AT SW1A AND
SW3A,SW7,
POROUS BACKFILL
DRAIN PIPE
WHERE REQUIRED
SEE CIVIL DRAWINGS
ROUGHEN CONTACT SURFACE
TO 1/4" AMPLITUDE
BEARING STRATUM
FOR NET ALLOWABLE
BEARING PRESSURE
SEE GENERAL NOTES
(TO BE VERIFIED BY
OWNER'S GEOTECHNICAL
TESTING AGENCY)
CLR
3"CLR3"CLR2"LTS 0" 0"CLR
2"
CLR
X"X'-X"SEE SCHED.
B
SEE SCHED.
C H SEE SCHED.SIDE BARS ES AS
REQUIRED
SEE SCHEDULE
MARK
SW1
A
(FT-IN)
1'- 6"
SIZE
B
(FT-IN)
1'- 6"
C
(FT-IN)
2'- 6"
W1
#5@12"
WALL REINFORCEMENT
DOWEL
BARS
W2
EARTH
SIDE
HORIZ
CONTINUOUS
BARS
F1
TOP BARS
FOOTING REINFORCEMENT
F2
BOTTOM
BARS
CONTINUOUS
BARS
f'c = 4.000PSI
REMARKS
SITE RETAINING WALL SCHEDULE
T
(IN)
12"
H
(FT-IN)
6'- 0"#5@12"#5@12" EF #5@12"#5@12" T&B#5@12"
SW1A 1'- 6"1'- 6"2'- 6"#5@12"NOTE 1, 410"6'- 0"#5@12"#5@12" EF #5@12"#5@12" T&B#5@12"
SW2 1'- 6"1'- 9"2'- 9"#5@12"12"8'- 0"#5@12"#5@12" EF #5@12"#5@12" T&B#5@12"
SW3 1'- 6"2'- 0"3'- 6"#5@12"12"9'- 0"#6@12"#5@12" EF #5@12"#5@12" T&B#5@12"
NOTES:
1.DESIGN IS BASED ON OPEN EXCAVATION AT 1V:1.5H SLOPE. IF NOT. NOTIFY EOR.
2. THE BACKFILL PLACEMENT SHALL BE APPLIED BOTH SIDES AT MAXIMUM DIFFERENCE OF 6'-0" BEFORE INTERIOR GRADE REACHES FINAL ELEVATION.
3. IF SW...* IS INDICATED ON PLANS, PROVIDE 3 #7 SIDE BARS ES AS SHOWN ON SECTIONS.
4. THE NOTED RETAINING IS BUILDING PERIMETER WALL. THEREFORE NO WEEP HOLES SHALL BE PROVIDED.
5. UPPER WALL TO BE 8" PER SECTION. REFER TO SECTION FOR WALL REINFORCEMENT.
6. SEE SECTION FOR WALL AND FTG REINFORCEMENT.
SW4 1'- 6"3'- 0"4'- 0"#5@12"12"12'- 0"#7@9"#5@12" EF #6@12"#5@12" T&B#6@12"
SW5 1'- 6"7'- 0"1'- 0"#5@12"12"12'- 0"#7@9"#5@12" EF #6@12"#5@12" T&B#6@12"
NOTE 2
NOTE 2
SW6 1'- 6"5'- 6"1'- 0"#5@12"12"10'- 0"#6@12"#5@12" EF #6@12"#5@12" T&B#6@12"NOTE 2
SW3A 1'- 6"2'- 3"3'- 6"#5@12"NOTE 3,410"11'- 0"#6@9"#5@12" EF #5@12"#5@12" T&B#5@12"
SW7 1'- 6"1'- 6"2'- 6"#4@12"8"4'- 0"#4@12"#4@12" EF #5@12"#5@12" T&B#5@12"NOTE 4
SW8 1'- 6"4'- 3"2'- 5"#4@12"10" NOTE 510'- 0"#7@6"#4@12" EF #6@12"#5@12" T&B#6@12"NOTE 4
SW9 1'- 6"0'- 11"3'- 1"18"10'- 0"NOTE 6 NOTE 4NOTE 6NOTE 6 NOTE 6 NOTE 6 NOTE 6
FIRST POUR SECOND POUR
1 1/2" DEEP CONTINUOUS
FORMED KEYWAY
CENTERED IN WALL
THICKNESS OR SCHEDULE3/4" DEEP CONTINUOUS
V-GROOVE WHERE WALL
IS EXPOSED TO VIEW
DISCONTINUE REINFORCEMENT
AT JOINT
T/3T/3T/3HORIZONTAL
REINFORCEMENT
VERTICAL
REINFORCEMENT
NOTE:
1. SEE GENERAL NOTES FOR CONSTRUCTION JOINT MAXIMUM SPACINGTSEE PLANTYP
2" CLR
3/4" DEEP CONTINUOUS
V-GROOVE WHERE WALL
IS EXPOSED TO VIEW
CUT ALTERNATING
HORIZONTAL BAR EACH FACE
OR SCHEDULETSEE PLAN 0" 0"DOWELS TO MATCH
SIZE AND SPACING
OF HORIZONTAL
BARS
PLACE ONE BAR
AT
OUTSIDE CORNER
HORIZONTAL REINF
SEE SECTION
VERTICAL REINF
SEE SECTION
#4 U-BARS TO MATCH
SPACING OF
HORIZONTAL BARS
END OF WALL
T
SEE PLAN
OR SCHEDULE LTS2' - 0"LTSLTS
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
TYPICAL SITE RETAINING WALL
DETAILS AND SCHEDULE
S2.12
TT
01.17.2018
NOT TO SCALE
TYPICAL SITE RETAINING WALL SECTION1
NOT TO SCALE
SITE RETAINING WALL SCHEDULE5
NOT TO SCALE
TYPICAL VERTICAL CONSTRUCTION JOINT - PLAN
AT SITE RETAINING WALL3
NOT TO SCALE
TYPICAL VERTICAL CONTRACTION JOINT - PLAN
AT SITE RETAINING WALL2
NOT TO SCALE
TYPICAL SITE RETAINING WALL DETAIL - PLAN4
T/FTG
STUD WALL BY OTHERS
T/SLAB
CL
WALL &
FTG
STD HOOK
STD HOOK
#4 DOWEL @
18" OC,
ALTERNATE
SIDES
NOTES:
1. FOR INFO NOT SHOWN
OR NOTED, SEE
1' - 0"
3" CLR @ NORTH/SOUTH REINF
4" CLR @ EAST/WEST REINF 2' - 0"
3" CLR, TYP1' - 6"SLAB ON GRADE
PER
TYP 0"1 1/2"1
S2.131' - 0"PER SCHEDULE"D"PER SCHEDULE
"W"
TYP
3" CLR
T/FTG
SLAB BLOCK OUT PER
T/SLAB
CL OF
COL &
FTG
#4 @ 18" OC, TYP
4 SIDES OF FTG
STD HOOK
STD HOOK
PER PLAN
CONT FTG REINF
THRU COL FTG
2' - 6 1/2"
FOR COL & BASE PL
INFO, SEE PLAN
NOTE:
PROVIDE 6" MIN CONCRETE COVER OVER COLUMN, BASE
PL & ANCHOR RODS BELOW GRADE, TYP.
BOT REINF
PER SCHEDTYP3" CLREDGE OF SLAB
AT EXT
CONDITION
SLAB ON GRADE
PER
TIES BEYOND
COLUMN FOOTING
0" TYP11"
3" CLR @ NORTH/SOUTH REINF
4" CLR @ EAST/WEST REINF
T/FTG
BOT REINF PER
PLAN NOTES
FINISH GRADE OR
PAVING WHERE
OCCURS
VARIES
REF
2' - 0"1' - 6"SLAB ON GRADE
8"
2 1/2"2' - 6"1' - 0"5 1/2"LTS#5 @ 12" OC
EW AND EF
#5 @ 8" OC
#4 DOWEL
@ 18" OC
NOTE:
1. SEE TYPICAL ISOLATED FOOTING - BASE PLATE WITHIN CONCRETE INFILL DETAIL FOR ADDITIONAL INFORMATION.
CL
COLUMN & FOOTING
T/SLAB ON GRADE
EL SEE PLAN
T/PIER
EL SEE PLAN
T/FOOTING
EL SEE PLAN
SEE TYPICAL SLAB ON
GRADE
ISOLATION JOINT DETAILS
18"X18" CONCRETE PIER ANCHOR RODS
2#4 TIES AT 3" OC
AT TOP OF PIER
SEE
FOR BALANCE
TO TIES
2" CLR
/1 S2.14
LOWER LEVEL
734' - 6"
A
1' - 6"
Ld
Ld
EXTENTS OF WALL
FOOTING BEYOND
METAL STUD BEARING
WALL BY OTHERS
FOOTING BOTTOM REINFORCEMENT
REFER TO PLAN AND FOOTING SCHEDULE
FOR FOOTING SIZE AND REINFORCEMENT
WALL DOWELS
NOT SHOWN FOR CLARITY
SEE WALL SCHEDULE
REFER TO
FOUNDATION PLANS
FOR TOP OF FOOTING
ELEVATION
H = "X"MINIMUM
2D
MINIMUM
H2'-6" MAXIMUMDMINIMUM
2H
MINIMUM
H
.HH = "X"CLEAR3"1
1 MAX
1
T/FOOTING
EL SEE PLAN
T/FOOTING
EL SEE PLAN
1 MAXLd
Ld
Ld
Ld
CLEAR2"NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
TYPICAL SHALLOW FOOTING
DETAILS AND SCHEDULES
S2.13
TT
01.17.2018
NOT TO SCALE2INTERIOR CONTINUOUS FOOTING
NOT TO SCALE3COLUMN FOOTING
NOT TO SCALE1EXTERIOR CONTINUOUS FOOTING
NOT TO SCALE
TYPICAL PIER ON ISOLATED FOOTING5
3/4" = 1'-0"
TYP SECTION AT INT TO EXT FOOTING4
NOT TO SCALE
TYPICAL STEPPED WALL FOOTING DETAIL6
CL
COLUMN
TYP
2" CLR #4 TIES @ 12" OC
8-#6 BARS
PER PLANPER PLAN
T/ FTG
CURB BEYOND
T/SLAB
REF
STD HOOK
STD HOOK
NOTES:
1. FOR INFO NOT SHOWN OR
NOTED, SEE
2. 3" COVER TO BE
MAINTAINED ON COLUMN,
BASE PLATE, AND ANCHOR
BOLTS.
PER SCHEDULE
"W"
TYP
3" CLRPER SCHEDULE"D"SLAB ON GRADE
PER
FINISH GRADE OR
PAVING WHERE
OCCURS
11"TYP.ADDITIONAL
BARS
HSS COLUMN
PER PLAN
CURB REINF
TYPICAL
11"
TYP
ADDITIONAL
BARS CURB REINF
HSS COLUMN
PER PLAN
AT CORNER
HSS COL
1
S2.13
A PLAN AT HSS COLUMN
8"
FOOTING SCHEDULE
MARK
F3 3'-0"x3'-0"x1'-6"
COMMENTS DETAIL
6-#5, EW, BOT
REINFORCINGSIZE
B x W x D
F3.5 3'-6"x3'-6"x1'-6"5-#6, EW, BOT
T/FTG
EL
"D""W" OR "B""B"
TOP OF
SLAB ELEV
"W"CL COLA FOOTING PLAN B FOOTING SECTION
CL COL CL COL
3
S2.13
3
S2.13
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
TYPICAL SHALLOW FOOTING
DETAILS AND SCHEDULES
S2.14
TT
01.17.2018
3/4" = 1'-0"
CONCRETE PIER1 3/4" = 1'-0"
EXTERIOR CONTINUOUS FOOTING WITH HSS COLUMN2 3/4" = 1'-0"
COLUMN FOOTING SCHEDULE3
A
A
A C
B
NOTES:
1. CONTRACTOR SHALL BE RESPONSIBLE FOR SHORING OR OTHERWISE MAINTAINING THE SIDES OF THE
EXCAVATION FROM CAVE-IN UNTIL ALL BACKFILL IS COMPLETED.
2. ALL PIPES AND CONDUITS SHALL CLEAR SLEEVE BY 1" ALL AROUND, UON
3. FIRE SERVICE LINES SHALL CLEAR SLEEVES 2" ALL AROUND.
4. TRENCHES FOR PIPES AND CONDUITS WITH INVERT ELEVATION BELOW 2'-6" FROM BOTTOM OF FOOTING
SHALL BE FILLED PER GEOTECHNICAL ENGINEER'S RECOMMENDATIONS.
5.CAULK SEAL GAP AT SLEEVE-TO-PIPE/CONDUIT INTERFACE ON EXTERIOR SIDE OF FOOTING.
B/FTG
T/FTG
T/SLAB
9"6" MIN
3'-0" MAXPIPES OR CONDUITS
WHERE OCCUR
SLEEVE, SEE DETAIL 2
ON THIS SHEET
1
2
CONTROLLED
LOW-STRENGTH
MATERIAL. f'c =
1200 PSI MIN.
FOR PIPE OR CONDUIT
PENETRATION IN THIS AREA, SEE
DETAIL 2 ON THIS SHEET
PIPE OR CONDUIT PENETRATION
NOT ALLOWED IN UPPER THIRD
OF FOOTING
DIGGING FOR PIPE OR CONDUIT TRENCH
PARALLEL TO FTG BELOW THESE LINES ARE
ONLY ALLOWED PRIOR TO PLACEMENT OF FTG
CONCRETE. SEE SOILS REPORT FOR BACKFILL
AND COMPACTION REQUIREMENTS
CONC
FILL
3 3/4"
9 3/8"6" MIN5 5/8"
1 1/2 x LARGEST
SLEEVE DIA (BUT
NOT LESS THAN 6")
2'-0" MIN
1'-6" MIN 4" MIN6" MIN2' - 2 1/4"
1' - 1 1/2"
PIPES ARE NOT ALLOWED
ANYWHERE BELOW FOOTINGS
1
1
CLASS "B" LAP
EA SIDE (2'-0" WHERE
TOP BARS DO NOT OCCUR)
ADD HANGER
STIRRUPS EA SIDE
TYPICAL
STIRRUPS
#4 BARS @ 18" OC.,
MIN OF 2
UNINTERRUPTED BARSSLEEVE, SEE FOR
MAX SIZE
TYP
2" CLR
ADD 1 STIRRUP EA SIDE
OF SLEEVE
ENLARGE STIRRUPS AT
DEEPENED FOOTING
MATCH SIZE & SPACING
OF TYP STIRRUPS
ADD BOT BARS, MATCH
SIZE & QUANTITY OF
INTERRUPTED BARS
INTERRUPTED BARS
SLEEVE, SEE
FOR MAX SIZE
NOTES:
1. DO NOT CUT REINFORCING AT OR . ONLY CUT INTERRUPTED
REINFORCING AT .
2. PROVIDE MINIMUM 2" CLEAR BETWEEN SLEEVE AND REINFORCING.
3. SEE DETAIL 1 ON THIS SHEET FOR SLEEVE-TO-PIPE/CONDUIT CLEARANCE &
INFO NOT NOTED.
4. CAULK SEAL GAP AT SLEEVE-TO-PIPE/CONDUIT INTERFACE ON EXTERIOR
SIDE OF FOOTING.
ADD 1 STIRRUP EA SIDE
OF SLEEVE
TYPICAL STIRRUPS
MAX OUTSIDE
SLEEVE DIA 12"
(NOMINAL)
DIA-1 OR DIA-2
3x LARGER OF
DIA-2 TYP
2" CLRDIA-1
MIND/3MIND/3DC PIPE OR CONDUIT BELOW
BOTTOM REINFORCEMENTBPIPE OR CONDUIT PENETRATION
BELOW MIDDLE THIRDAPIPE OR CONDUIT PENETRATION
THRU MIDDLE THIRD
TYP
2" CLR
OR D
SMALLER OF
(3xDIA-1)
END OF
FOOTING
LAP SPLICE
CLASS "B"
STIRRUPS @ 4" OC
ALONG LENGTH OF
SPLICE
1
6
OMIT TIE AT PIPE OR
CONDUIT
OMIT TIE AT PIPE
OR CONDUIT, TYP
5. IF PIPE OR CONDUIT PENETRATION OCCURS AT EITHER TOP OR BOTTOM
REBAR SPLICE LOCATION PROVIDE 2 ADDITIONAL SHEAR STIRRUPS FOR A
TOTAL OF 4 SHEAR STIRRUPS ON EACH SIDE OF PENETRATION.
6. IF PIPE OR CONDUIT SLEEVE IS ASTM A53 SCHEDULE 40 OR GREATER PIPE,
ADDITIONAL STIRRUPS MAY BE ELIMINATED. SLEEVE SHALL BE
GALVANIZED.
ADDITIONAL
STIRRUPS
DO NOT CUT
SCHED REINF
KEY FORM WITH 3x
#6x5'-6" @ 6" OC
(2 MIN)
T&B REINF
PER SCHED
CL SPAN
3" 3" 2" 2" 3" 3"
2'-9" TYP 4"4"DD/3 D/3 D/3
...
2ND POUR1ST POUR
A.
FOOTING,
WHERE OCCURS
STD HOOK,
TYP STD HOOK,
TYP
FOOTING
LONGITUDINAL
BAR, TYP
FOOTING
LONGITUDINAL
BAR, TYP
PLAN 0", TYP0", TYP TYP
2" TO FIRST TIE,
OR HORIZONTAL BAR,.2" TO FIRST TIE,
OR HORIZONTAL BAR,
TYP
T/SLAB
T/FTG
DSTEP IN TOP OF FTG MARKED ON PLAN:
S S
DENOTES APPROXIMATE LOCATION OF STEP IN
FTG; CONTRACTOR TO COORDINATE LOCATION.
MAX OF 12" OR 2D/3
1' - 0"PROVIDE FOOTING
TIES THRU STEP
ADDITIONAL
TIE AT STEP,
TYP
STANDARD
HOOK, TYP
3" CLR, TYP
CLASS "A" LAP SPLICE, TYP
LONGITUDINAL REINF PER
DETAIL OR SCHEDULE, TYP
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
TYPICAL SHALLOW FOOTING
DETAILS
S2.15
TT
01.17.2018
NOT TO SCALE1PIPE OR CONDUIT CLEARANCE AT FOOTINGS
NOT TO SCALE2
PIPE OR CONDUIT PENETRATIONS THRU
CONTINUOUS FOOTINGS
NOT TO SCALE3VERTICAL CONSTRUCTION JOINTS IN FOOTINGS
NOT TO SCALE4CONTINUOUS FOOTING INTERSECTIONS
NOT TO SCALE5SINGLE STEP IN FOOTING
PER SCHEDULE
WIDTH
3" CLR @ NORTH/SOUTH REINF
4" CLR @ EAST/WEST REINF TYP
3" CLR
T/SLAB
T/GB
B1 & B2 BOT REINF
PER SCHEDULE
T1 & T2 TOP REINF
PER SCHEDULE
TIES PER SCHEDULE
W/ ALTERNATE 90 DEG
HOOKS EA SIDE
SLAB PER
#4 DOWEL
@ 12" OC
STD HOOK
SIDE BARS EA SIDE
PER SCHEDULELAP SPLICECLASS "A"0" TYP3' - 6"PER SCHEDULEDEPTHPER SCHEDULE
WIDTH
3" CLR @ NORTH/SOUTH REINF
4" CLR @ EAST/WEST REINF
T/ SLAB
T/ GB
B1 & B2 BOT REINF
PER SCHEDULE
T1 & T2 TOP REINF
PER SCHEDULE
TIES PER SCHEDULE
W/ ALTERNATE 90 DEG
HOOKS EA SIDE
SLAB PER
#4 DOWEL
@ 12" OC
STD HOOK
MIN6"PLAN
SEEFINISH GRADE OR
PAVING WHERE
OCCURS
CURB, SEE
SIDE BARS EA SIDE
PER SCHEDULELAP SPLICECLASS "A" TYP
3" CLR
D1
TIES S1
D1
TIES S1
CL
T/ GB
T/ SLAB
CLASS "B" LAP
SPLICE AT
MIDSPAN AS
REQD
TYP TOP BARS
CONT, T1
WF COLCLASS "B" LAP SPLICE
OVER PILE CAP AS REQD
TYP BOTTOM BARS CONT, B1
TYP TIES PER SCHED
NOTES:
1. FIRST TIE AT THE SUPPORT SHALL BE PLACED NO MORE THAN 2" FROM FACE OF
SUPPORT.
2. ALL TIES NOT SHOWN FOR CLARITY.
2"0"TYP0" TYPCL CL
TIES @ 4" OC WF COLWF COLGRADE BEAM
2
S2.16
Sim
3
S2.16
PARALLEL GRADE BEAM,
WHERE OCCURS
LONGITUDINAL BARS
CONTINUOUS THROUGH
PARALLEL GRADE BEAMS
GRADE BEAM
LONGITUDINAL REINFTYP0" STD HOOKS, TYP
2" TO FIRST
TIE, TYP
LAP SPLICE
CLASS "B"2' - 0"
LAP SPLICE
CLASS "B"
2' - 0"4" MAXSEE PLANT/SLAB
T/GB
BOTTOM REINF
PER GB SCHEDULE
NOTE:
FOR SLAB DEPRESSION INFO, SEE
TOP REINF PER
GB SCHEDULE
TIES PER GB
SCHEDULE
SLAB PER
5'-0".GB WHERE
OCCURS
PER PLAN
#4 VERT
@ 12" OC,
TYP
#4 @ 9" OC
TOP & BOT
PROVIDE WATER
STOP @ CONSTRUCTION
JOINT TYP, SEE ARCH
#4 HORIZ
@12" OC
NOTES:
1. FOR GRADE BEAM INFO NOT SHOWN OR NOTED, SEE .
2. FOR SLAB INFO NOT SHOWN OR NOTED, SEE .CONC SLAB
PER PLAN
B/ ELEVATOR
PIT
#4 @ 9" OC
TOP & BOT
1' - 0"LAP SPLICE, TYPCLASS "B"ROUGHEN CONTACT
SURFACE TO 1/4"
AMPLITUDE
T/FIRST FLOOR
SLAB ELEV
3
S2.16
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
GRADE BEAM DETAILS
S2.16
TT
01.17.2018
NOT TO SCALE2INTERIOR GRADE BEAM
NOT TO SCALE3EXTERIOR GRADE BEAM
NOT TO SCALE1GRADE BEAM REINFORCING ELEVATION
NOT TO SCALE4GRADE BEAM INTERSECTIONS
NOT TO SCALE5GRADE BEAM AT SLAB DEPRESSION
NOT TO SCALE6ELEVATOR PIT AT GRADE BEAM
LOWER LEVEL
734' - 6"
AC
GROUND FLOOR
744' - 6"
SECOND FLOOR
754' - 3"
THIRD FLOOR
764' - 0"
FOURTH FLOOR
773' - 9"
T/MD - ROOF
783' - 3 3/4"
B
778' - 4 3/4"
768' - 10 1/2"
750' - 5 1/2"
759' - 1 1/2"
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
LOWER LEVEL
734' - 6"
5 4.5
GROUND FLOOR
744' - 6"
SECOND FLOOR
754' - 3"
THIRD FLOOR
764' - 0"
FOURTH FLOOR
773' - 9"
T/MD - ROOF
783' - 3 3/4"
4.9
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
S5.02
2
LOWER LEVEL
734' - 6"
5 4.5
GROUND FLOOR
744' - 6"
SECOND FLOOR
754' - 3"
THIRD FLOOR
764' - 0"
FOURTH FLOOR
773' - 9"
T/MD - ROOF
783' - 3 3/4"
4.9
759' - 1 1/2"
768' - 10 1/2"
778' - 4 3/4"
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
STAIR 1 FRAMING ELEVATIONS
S3.01
TT
01.17.2018
1/4" = 1'-0"
STAIR 1 NORTH ELEVATION1 1/4" = 1'-0"
STAIR 1 EAST ELEVATION2 1/4" = 1'-0"
STAIR 1 WEST ELEVATION3
NOTE: SEE PLAN FOR INFORMATION NOT SHOWN; SUCH AS CONNECTION FORCES, COLUMN INFORMATION, ETCETERA
LOWER LEVEL
734' - 6"
D E
GROUND FLOOR
744' - 6"
SECOND FLOOR
754' - 3"
THIRD FLOOR
764' - 0"
FOURTH FLOOR
773' - 9"
T/MD - ROOF
783' - 3 3/4"
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
778' - 4 3/4"
768' - 10 1/2"
759' - 1 1/2"
749' - 4 1/2"
LOWER LEVEL
734' - 6"
1 2
GROUND FLOOR
744' - 6"
SECOND FLOOR
754' - 3"
THIRD FLOOR
764' - 0"
FOURTH FLOOR
773' - 9"
T/MD - ROOF
783' - 3 3/4"
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
759' - 1 1/2"
749' - 4 1/2"
768' - 10 1/2"
778' - 4 3/4"
LOWER LEVEL
734' - 6"
1 2
GROUND FLOOR
744' - 6"
SECOND FLOOR
754' - 3"
THIRD FLOOR
764' - 0"
FOURTH FLOOR
773' - 9"
T/MD - ROOF
783' - 3 3/4"
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
STAIR 2 FRAMING ELEVATIONS
S3.02
TT
01.17.2018
1/4" = 1'-0"
STAIR 2 SOUTH ELEVATION1 1/4" = 1'-0"
STAIR 2 WEST ELEVATION2 1/4" = 1'-0"
STAIR 2 EAST ELEVATION3
NOTE: SEE PLAN FOR INFORMATION NOT SHOWN; SUCH AS CONNECTION FORCES, COLUMN INFORMATION, ETCETERA
LOWER LEVEL
734' - 6"
F
GROUND FLOOR
744' - 6"8"8"8"SITE RETAINING WALL
SEE PLAN
CIP CONC STAIR WITH #5 AT
12" OC EW BOTTOM IN 8" SLAB
AND #4 NOSE BAR
PROVIDE SHEAR KEY
GALVANIZED W8.
1/2" EXPANSION JOINT WITH
COMPRESSIBLE FILLER MATERIAL
5 1/2"1' - 6" 2' - 6"
S4.01
2
F
GROUND FLOOR
744' - 6"
743' - 9 5/8"
HSS POST BEYOND
CONT 3/8"X5" EMBED
WITH 1/2"DIA.X 3" SHEAR
STUDS AT 16" OC.
W BEAM SEE PLAN
5"
1/2"(4) 3/8"X4"X4" POLISHED SS
PLATE (RMS<20) WELDED TO
EMBED - 1 PL AT EACH BEAM
END WITH BALANCE EQ SPACED
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
SECTION AT ENTRY STAIR
S4.01
TT
01.17.2018
1/2" = 1'-0"
SECTION AT EAST STAIR I1 1 1/2" = 1'-0"
SECTION AT EAST STAIR II2
CL
COLUMN
FINISHED COLUMN
END SURFACE
1" Ø ANCHOR ROD
FINISH BASE PLATE
NON-SHRINK
GROUT
CL
COLUMN
CL
COLUMN
ELEVATION
SQUARE HSS ON FOOTING PLAN3/4" TYPNOTES:
1. SEE PLAN FOR BASE PLATE SIZE AND ORIENTATION
2. BASE PLATE THICKNESS SHOWN ON SCHEDULE IS A MINIMUM. DIMENSION AFTER ALL
MILLING IS COMPLETED
3. COLUMN STABILITY DURING ERECTION IS RESPONSIBILITY OF CONTRACTOR
4. SEE ANCHOR ROD SCHEDULE AND TYPICAL ANCHOR ROD DETAIL FOR
ADDITIONAL INFORMATION
5. CONTRACTOR'S OPTION TO FIELD WELD COLUMNS TO BASEPLATES FOR HEAVY
BASEPLATES
6. ANCHOR ROD CONFIGURATION IS TO USE SQUARE PATTERN OUTSIDE COLUMN.
T/FOOTING OR WALL
EL SEE PLANS
CL
COLUMN
CL
COLUMN
5"2 1/2"2 1/2"
2 1/2"
1' - 4"
CONC WALL
SEE SECTION 1' - 4"TYP
2 1/2"
1' - 4"
SQUARE HSS ON CONC WALL PLAN
EXTENTS OF
CURB ABOVE
SEE SECTION 10"8"2" 4" 2"2" MINIMUM4" MINIMUMCOVERT/CONCRETE
EL SEE PLANS, DETAILS
OR SCHEDULES
SEE ANCHOR ROD
SCHEDULE FOR WELD A
FULLY TIGHTENED DOUBLE NUTS
OR HEX BOLT HEAD
12" TYP
NOMINAL GROUT THICKNESS
PER SCHEDULE A
HEAVY HEX NUT
SQUARE OR ROUND PLATE
WASHER WITH STANDARD HOLE
SIZE AND THICKNESS PER
SCHEDULE A
MINIMUM ANCHOR ROD PROJECTION
ABOVE BASE PLATE PER SCHEDULE ATHREAD LENGTH
BASE PLATE W/ OVERSIZED
HOLE, PER SCHEDULE A
MIN PROJ
ABOVE
BASE PL
MIN
WASHER
t
MIN
WASHER
SIZE
BASE PL
HOLE DIA
ANCHOR
ROD
DIAMETER
SCHEDULE A
NOMINAL
GROUT
THICKNESS
ANCHOR ROD PER
BOTTOM OF CONCRETE
BOTTOM OF BASE PLATE
SETTING NUT AND PLATE WASHER
(1/2" MINIMUM WASHER THICKNESS)
OR SHIM STACK AT CONTRACTOR'S
OPTION / COORDINATION
1' - 2 3/4"
4"
5 1/2"
3 3/4"
1' - 11
3
/
8
"
3/4"1-5/16"2"1/4"3"2"
1"1-13/16"3"3/8"3-1/2"2"
1-1/4"2-1/16"3"1/2"4"3"
2 1/2"
1/4
/1 S5.01
4.3
GROUND FLOOR
744' - 6"
CFMF WALL OR HSS COLUMN
ABOVE PER PLAN
SS COLUMN WITH 1/4" CAP
PLATE SEE PLAN
CFMF SEE PLAN
(2) .157"Ø P.D.F. AT 2" OC
BS AT CONT HSS COLUMN
(2) .157"Ø P.D.F. AT 2" OC
AT TOP OF HSS COLUMN
BELOW TYP
CONT TOP/BOTTOM TRACK
(18GA MIN AT COLUMN AND
EXTEND 3' BEYOND TO LAP
WITH TYP TRACK) NOTCH WEB
AT THRU COLUMN AND BEND
TO SIDE OF COLUMN FOR
ATTACHMENT
2
GROUND FLOOR
744' - 6"
PROVIDE BOX BEAM
CENTERED ON HSS AND
DESIGN FOR ADD'L AXIAL
LOADS INDICATED ON PLAN
PROVIDE TWIST STRAP BS
WITH P.D.F. TO HSS TO
TRANSFER AXIAL LOADS
INDICATED ON PLAN
HSS SEE PLAN
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
TYPICAL STEEL COLUMN
DETAILS
S5.01
TT
01.17.2018
3/4" = 1'-0"
TYPICAL BASE PLATE DETAIL1 3/4" = 1'-0"
TYPICAL ANCHOR ROD DETAIL2
1 1/2" = 1'-0"
HSS COLUMN TO CFMF CONNECTION3 1 1/2" = 1'-0"
SECTION AT WIND COLLECTOR BEAM4
HSS
SEE PLAN
CL
COLUMN
NOTE:
1. CONTRACTOR'S CALCULATIONS SHALL VERIFY HSS WALL
THICKNESS IS ADEQUATE FOR CONNECTION TYPE CHOSEN PER AISC
AISC SIMPLE SHEAR
CONNECTION DOUBLE ANGLE,
SINGLE ANGLE,
SHEAR END PLATE, WT, OR
SINGLE PLATE CONNECTION
(SINGLE PLATE SHOWN)
COLUMN CAP 1 1/2" TYP UON5/8 X SINGLE-PLATE
THICKNESS
CONCRETE WALL
HORIZONTAL SLOTTED HOLES
IN CONNECTION, STANDARD
HOLES IN BEAM (PLATE
WASHER NOT SHOWN)
EMBED PLATE WITH HEADED STUDS
SEE SCHEDULE
DESIGN CONNECTION AS AISC
SINGLE-PLATE CONNECTION WITH
SNUG TIGHT (NOT PRETENSIONED)
BEARING BOLTS
HORIZONTAL SPACES
EQUAL VERTICAL SPACES EQUAL2 1/2" NOMINAL, 3 1/2" MAXIMUM
ECCENTRICITY OF BOLT
GROUP, UNLESS OTHERWISE
NOTED
PROVIDE NAIL HOLE
TO NAIL PLATE TO
FORM AS
REQUIRED
SECTIONELEVATIONSTUD ROWSSTUD
COLUMNS
B Dt
CENTER PLATE
ON MEMBER
.1 1/2" TYP UON0" @ T/WALLEQ EQ EQ EQ
2" TYPICAL EQ EQ
..T/STEEL BEAM
EL SEE PLAN
BLOCK BEAM BOTTOM FLANGE AS
REQUIRED TO ACHIEVE MINIMUM
CONNECTION DEPTHDEPTH (SEE SCHEDULE)MINIMUM CONNECTION .
NOTES:
1. CONTRACTOR SHALL DESIGN SINGLE-PLATE GRADE, THICKNESS, BOLT
QUANTITY AND TYPE (A325, A490, N OR X) TO RESIST THE SHEAR
FORCE SHOWN IN TABLES OR PLANS WHILE SATISFYING GEOMETRIC
REQUIREMENTS OF THE TYPICAL EMBED PLATE DETAIL AND
SCHEDULE. SEE GENERAL NOTES FOR ADDITIONAL INFORMATION
REGARDING THE DESIGN OF STRUCTURAL STEEL CONNECTIONS
2. EMBED PLATES SHALL CONFORM TO ASTM A572, Fy=50 ksi
3. STUDS SHALL BE 3/4" DIAMETER X 8" LONG NOMINAL (MINIMUM)
4. SEE TYPICAL EMBED DETAIL FOR ASSUMED CONNECTION LOCATION
RELATIVE TO EMBED PLATE. REPORT ANY AS-BUILT DEVIATION FROM
THE ASSUMED CONDITION TO THE SER AS FOLLOWS:
HORIZONTAL DEVIATION GREATER THAN 2"
VERTICAL DEVIATION GREATER THAN 1"
30 6
REMARKS
EMBED PLATE SCHEDULE
MAXIMUM FACTORED
VERTICAL BEAM
SHEAR REACTION
(KIPS)
EMBED PLATE
SIZE No STUD
COLUMNS
2
MINIMUM
CONNECTION
DEPTH
(IN)t (in) X B (in) X D (in)
3/4 X 10 X 10
No STUD
ROWS
2
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
TYPICAL STEEL BEAM DETAILS
S5.02
TT
01.17.2018
1" = 1'-0"
TYPICAL BEAM TO HSS COLUMN SHEAR CONNECTION1 3/4" = 1'-0"
TYPICAL EMBED PLATE CONNECTION (SHEAR ONLY)2
1" = 1'-0"
EMBED PLATE SCHEDULE (SHEAR ONLY)3
2.5
2.6
F
2
S5.11
1/4" SS PLATE
SLOPED SEE
ARCH DWG 4' - 11 7/8"1' - 4"3' - 3"
3/8" SS PL OUTRIGGERS
DEPTH VARIES PER
ARCH DWG TYP.
NOTES: ECLOSURE AND MISC PLATES
NOTE SHOWN FOR CLARITY. REFER TO
ARCH DWG FOR ADD'L INFORMATION
F
SECOND FLOOR
754' - 3"
PROVIDE TIGHT FIT BLOCKING AT
16"(MAX) OC BY 2 BAYS ALIGN WITH
CANOPY OUT RIGGER
CFMF SEE ARCH DWG
3' - 3"
1/4"
(1/4")
1/4"3 1/2"1/4" SS PLATE SEE PLAN
3/8" SS OUTRIGGER PLATE 1/4"TYP
L3X3X5/16XCONT
1/4"
HSS10X6 SEE PLAN
1/2" SS ENCLOSURE
PLATE TYP
18GA X2" PLATE WITH (4) .157"Ø P.D.F TO
HSS AND (5) #12 SCREWS AT 1" OC IN 2
ROWS (10 TOTAL) IN BLOCKING
18GA X2" PLATE WITH (4) #12 CREWS TO C
STUD AND (5) #12 SCREWS AT 1" OC IN 2
ROWS (10 TOTAL) IN BLOCKING
T/MD - ROOF
783' - 3 3/4"6' - 0"6" 6"
HSS 4X4 WIND SCREEN POST
SEE PLAN FOR LOCATIONS
AND SIZES WITH 1/4" CAP
PLATE GROOVE WELD ALL
AROUND
HSS 4X4X5/16 HORIZONTAL
BTWN POST TYP
CFMF SEE PLAN WITH
ADD'L JOIST/BLOCKING/TOP
PLATE AS REQUIRED
1/4"TYP
1/4"TYP
1/2"X12"X12" GRADE
50 BASE PLATE
WITH (4) 1/2"Ø 9" OC
EACH WAY 5' - 0"SCREEN WALL
SEE ARCH DWG
1.10KIPS
(ASD)
3.70 K-FT
(ASD)
NOTES: THE WIND LOADS IMPOSED ON CORNER POST CAN BE
REDUCED BASED ON TRIBUTARY WIDTH BUT LOADS SHALL BE
APPLIED IN BOTH DIRECTIONS (NOT SIMULTANEOUSLY).
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
STEEL SECTIONS AND DETAILS I
S5.11
TT
01.17.2018
1" = 1'-0"
PLAN VIEW OF EAST ENTRY CANOPY1 3" = 1'-0"
CANOPY SECTION2
1 1/2" = 1'-0"
SECTION AT WIND SCREEN POST3
3
4
3.2
3.5
F
2
S5.12
HSS4X4X3/8
HSS4X4X3/8
HSS4X4X1/4 SS L4X3X1/4(LLV) SLOPED SEE ARCH DWG TYP UON HSS4X4X1/4HSS10X4 (HI) SEE FLOOR PLAN HSS10X4(HI) SEE FLOOR PLAN CANOPY SEE ARCH DWG
FOR GEOMETRY 1' - 2 5/16"3/8" SS EDGE
PLATE TYP4' - 4"11"2' - 0"
1/4" SS PLATE
SLOPED SEE
ARCH DWG TYP
5' - 3 1/4"5' - 7 1/16"NOTES: ENCLOSURE PLATE
AND MISC STEEL NOT
SHOWN FOR CLARITY REFER
TO ARCH DWG FOR ADD'L
INFORMATION
F
THIRD FLOOR
764' - 0"
1/4"TYP
2' - 0"
1/4" SS PLATE SLOPED
SEE PLAN
SS L4X3 SLOPED
1/4"TYP
1/4"TYP
1/4" 2 1/2"
TYP
MIN
SS 3/8" EDGE PLATE
SEE PLAN
1/4"TYP
ENCLOSURE PLATE SEE
ARCH DWG
HSS SEE PLAN CFMF FRAMING
SEE PLAN
L3 1/2X3 1/2X 0'-4" BS
WITH 7/8"Ø AS 325 SC
THRU. BOLT TYP
1/4"TYP
1/4"TYP
DOOR HEAD SEE PLAN
CFMF WALL SEE PLAN
BY OTHERS
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
STEEL SECTIONS AND DETAILS II
S5.12
TT
01.17.2018
1/2" = 1'-0"
PLAN VIEW AT LEVEL 3 CANOPY1
3" = 1'-0"
SECTION AT LEVEL 3 CANOPY2
NOTES:
1.PROVIDE THE GREATER QUANTITY OF TYPICAL MINIMUM VERTICAL
REINFORCEMENT AS SHOWN IN THE VERTICAL REINFORCEMENT SCHEDULE
OR THE SEISMIC SCHEDULE AS FOLLOWS FOR THE FOLLOWING WALL
TYPE AND DESIGN PRESSURE, UON
- TYPICAL INTERIOR WALLS 5 PSF
- INTERIOR ELEVATOR SHAFT WALLS 10 PSF
- EXTERIOR WALLS 26 PSF (ASD)
- SEISMIC
SEE MINIMUM SEISMIC REINFORCEMENT SCHEDULE
2.PROVIDE THE FOLLOWING TYPICAL MINIMUM HORIZONTAL REINFORCEMENT:
- INTERIOR WALLS:2 - 9 GAGE WIRES AT EVERY OTHER COURSE
- EXTERIOR WALLS:2 - 3/16" DIA WIRES AT EVERY OTHER COURSE
- SEISMIC DESIGN CATEGORY D, E, AND F PROVIDE HORIZONTAL
REINFORCEMENT USING BOND BEAMS AS FOLLOWS:
- 1# 4 @ 48" OC FOR 6" THICK WALL
- 2# 4 @ 48" OC FOR WALLS > 6" THICK
3.FOR LOCATION AND THICKNESS OF MASONRY WALLS SEE ARCHITECTURAL
DRAWINGS
4.VERTICAL REINFORCEMENT SCHEDULE IS BASED ON DESIGN SERVICE LOAD
PRESSURE AS NOTED
5.'H' INDICATES HEIGHT OF WALL BETWEEN LATERAL SUPPORT POINTS
6. DESIGN OF MASONRY WALL IS BASED ON PARTIALLY GROUTED WALLS WITH
REINFORCEMENT AS SCHEDULED
7.DESIGN IS BASED ON A MINIMUM COMPRESSIVE STRENGTH f'm = 1500 PSI MINIMUM
FOR PROJECT SPECIFIC f'm REFER TO GENERAL NOTES ON S0 SERIES
DRAWINGS
8. VERTICAL REINFORCEMENT SHALL BE SECURED WITH WIRE POSITIONERS ETC.,
AT INTERVALS NOT TO EXCEED 48," AND BE LOCATED AT THE CENTER OF THE
WALL UON
9.SEE ELEVATIONS AND DETAILS FOR ADDITIONAL REINFORCEMENT AT
OPENINGS AND JOINTS
VERTICAL REINFORCEMENT (SEE NOTE 1)
WALL
THICKNESS
t
MAXIMUM
WALL
HEIGHT
H 5 PSF 10 PSF
12'-0"#4@120"#4@96"
6"
30 PSF
#4@32"
14'-0"#4@120"#4@64"#5@32"
12'-0"#4@120"#4@120"#4@48"
14'-6"#4@120"#4@96"#4@32"
17'-0"#4@120"#4@72"#5@32"
19'-0"#4@96"#4@56"#6@32"
8"
13'-6"#4@120"#4@120"#4@48"
16'-0"#4@120"#4@112"#4@32"
20'-0"#4@120"#4@64"#5@32"
23'-6"#4 @ 88"#4@48"2#6@48"
10"
14'-0"#4@120"#4@120"#4@48"
18'-0"#4@120"#4@112"#4@32"
22'-6"#4@120"#4@72"#5@32"
26'-0"#4@104"#4@48"#6@32"
12"
29'-0"#4@72"#4@32"2#6@40"
MASONRY UNIT
ONE BAR
PER CELL LAYOUT
TWO BAR
PER CELL LAYOUT
TYPICAL REINFORCEMENT LAYOUT
BAR AT OUTSIDE
FACES OF CELL
[NOTED AS: 2#4]
BAR
CENTERED
ON CELL
DESIGN PRESSURE (PSF)
OR REINFORCEMENTSEISMIC
DESIGN
CATEGORY
S
6" WALL
ALLA OR B
[A ONLY]
<0.25
<0.33
<0.50
B [OR C]
<1.0 [<0.67]D, E, OR F
DS
5
8" WALL 10" WALL 12" WALL
5 5 5
5 6[10]5 [10]10
5 [10]10 10 10 [30]
10 10 [30]10 [30]30
#5@32"#5@32"#6@32"#6@24"
MINIMUM SEISMIC REINFORCEMENT SCHEDULE
SEISMIC TABLE NOTES:
A.REFER TO GENERAL NOTES ON S0 SERIES DRAWINGS FOR APPLICABLE
SEISMIC DESIGN CATEGORY
B.FOR SEISMIC USE GROUP IV FACILITIES AND FOR WALLS WITH
COMPONENT IMPORTANCE FACTOR, Ip=1.5, VALUES INDICATED IN [ ]
SHALL BE USED
C.REINFORCEMENT IS BASED ON THE FOLLOWING CRITERIA, UON:
FULL HEIGHT WALLS WITHIN LIMITS OF VERTICAL REINFORCEMENT
SCHEDULE
ap=1.0
Rp=2.5
z/H=1 (WALL AT TOP OF STRUCTURE)
D. FOR WALL TYPES NOT INDICATED IN THE SCHEDULE SER SHALL BE
IMMEDIATELY NOTIFIED
E.SEISMIC MASS IS BASED ON PARTIALLY GROUTED WALLS
F.CONNECTION TO DIAPHRAGM IS TO BE 3 TIMES WALL PRESSURE.
VERTICAL REINFORCEMENT SCHEDULE
HORIZONTAL BAR(S)
WHERE SCHEDULED
IN BOND BEAM
(NOT SHOWN)
HORIZONTAL BAR(S)
WHERE SCHEDULED
IN BOND BEAM
(NOT SHOWN)
3/4" CLEAR
26 PSF
23'-0"#5@16"---
-
-
-
-
-
-
-
-
-
-
-
-
-
MAXIMUM
MASONRY
OPENING
'L'
6" WALL 8" WALL 10" WALL 12" WALL
LINTEL LINTEL LINTEL LINTEL
(2)L2.5x2.5x1/4
WALL THICKNESS
(2)L3.5X3X1/4 LLV (2)L4X4X1/4 (2)L5X5X5/164'-0"
(2)L3X2.5X1/4 LLV (2)L3.5X3X1/4 LLV (2)L4X4X1/4 (2)L5X5X5/165'-0"
(2)L3X2.5X1/4 LLV (2)L3.5X3X1/4 LLV (2)L4X4X1/4 (2)L5X5X5/166'-0"
(2)L3.5X2.5X5/16 LLV (2)L5X3X1/4 LLV (2)L4X4X5/16 (2)L5X5X5/167'-0"
(2)L5X3X5/16 LLV (2)L6X4X3/8 LLV8'-0"
W8X10 (2)L5X3X3/8 LLV (2)L6X4X3/8 LLV W8X24 + 1/4"x10" PLATE10'-0"
W8X10 (2)L6X3.5X3/8 LLV (2)L7X4X3/8 LLV12'-0"
NOTES:
1.LINTEL ANGLES AND W-SHAPE LINTELS SHALL BE ASTM A36 STEEL MINIMUM
2. NO MORE THAN SIX COURSES OF CMU MAY BE PLACED, REINFORCED,
GROUTED AND CURED AT ONE TIME ABOVE LINTEL BEFORE PROCEEDING
FURTHER
3. PROVIDE MINIMUM 8" BEARING EACH END
4.2L LINTELS SHALL BE WELDED OR BOLTED TOGETHER AT INTERVALS NOT
EXCEEDING 2'-0" OC, WITH A MINIMUM OF TWO CONNECTIONS BETWEEN
ENDS
5.AT EXTERIOR WALL SYSTEMS AND AT HUMID LOCATIONS LINTELS SHALL BE
GALVANIZED, REFER TO SPECIFICATIONS FOR FURTHER INFORMATION
6.SEE ARCHITECTURAL DRAWINGS FOR FIREPROOFING REQUIREMENTS
7.SEE TYPICAL CMU NON-BEARING WALL ELEVATION WITH STEEL OR
PRECAST LINTELS FOR DETAILS OF REINFORCEMENT AROUND OPENINGS
STEEL LINTEL WITH PLATE
(2)L5X5X5/16
W8X24 + 1/4"x10" PLATE
0"
VERTICAL WALL REINFORCMENT
SEE SCHEDULE
W-SHAPE LINTEL
SEE SCHEDULE
PLATE PER SCHEDULE
1/2" DIA x 6" LONG HEADED
STUD AT 4'-0" OC CENTERED ON
BEAM
IN GROUTED CELL
MINIMUM 2 PER LINTEL
3/16 4@12
3/16 4@12
(2)L3.5X2.5X3/8 LLV
SEE TYPICAL CMU SILL AND LINTEL
SCHEDULE (NON-BEARING WALL)
FOR REINFORCEMENT
SCHEDULED REINFORCEMENT
CONDITION
CMU LAP SPLICE AND TENSION EMBEDMENT LENGTH
(f'm = 1500 psi & fy = 60 ksi)
ONE BAR IN CELL
OR COURSE (NOTE 1)
#4
24"
36"
#5
26"
45"
#6
NOTES:
1.FOR 6" AND 8" WALLS WITH ONE HORIZONTAL BAR IN COURSE, USE SPLICE LENGTHS FOR TWO BARS IN CELL OR COURSE
2. WHERE EPOXY-COATED REINFORCEMENT IS USED, INCREASE LAP SPLICE LENGTH BY 50%
3.SPLICES OF HORIZONTAL REINFORCEMENT IN WALLS CONTAINING TWO BARS PER COURSE
SHALL BE STAGGERED
4.TYPE 1 OR TYPE 2 MECHANICAL SPLICES MAY BE SUBSTITUTED UON, PROVIDED THEY
DEVELOP 125% OF THE YIELD STRENGTH OF THE BAR AND ARE APPROVED BY THE EOR
5.WHERE BARS OF DIFFERENT SIZES ARE TO BE SPLICED, THE SPLICE LENGTH SHALL BE THAT
REQUIRED FOR THE LARGEST
6.SEE TYPICAL REINFORCEMENT LAYOUT DETAIL FOR MINIMUM CLEAR COVER TO INSIDE OF FACESHELL
7.SPLICES OF HORIZONTAL REINFORCEMENT SHOULD BE PLACED VERTICALLY OVER MAIN BAR
40"
54"
CMU
REINFORCEMENT CONDITIONS
TWO HORIZONTAL
BARS IN COURSE
BAR SIZE
TWO BARS IN CELL
OR COURSE
ONE HORIZONTAL
BAR IN CELL
CMU
ONE HORIZONTAL
BAR IN CELL
TWO VERTICAL
BARS IN CELL
ONE VERTICAL
BAR IN COURSE
TWO HORIZONTAL
BARS IN COURSE
CLEAR
COVER
CLEAR BAR
SPACING2 3/4"6 1/4"
CLEAR
COVER
CLEAR BAR
SPACING3 1/4"3 1/4"
SPLICE BAR LOCATION
TYPICAL FOR
HORIZONTAL BARS
SEE NOTE 7
EQ EQ
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
MASONRY TYPICAL DETAILS I
S6.01
TT
01.17.2018
NOT TO SCALE
TYPICAL CMU NON-BEARING WALL REINFORCEMENT SCHEDULE1 NOT TO SCALE
TYPICAL STEEL LINTEL SCHEDULE (NON-BEARING WALL)2
NOT TO SCALE
CMU LAP SPLICE AND TENSION EMBEDMENT LENGTH SCHEDULE3
MAXIMUM
MASONRY
OPENING
'L'
6" WALL (NOTE 5)
LINTEL
OR SILL
DEPTH
WALL THICKNESS
FULLY GROUT ALL CELLS FOR FULL
HEIGHT OF LINTEL DEPTH SCHEDULED
BOND BEAM AT SECOND COURSE WITH
REINFORCEMENT PER SCHEDULE. WHERE
REINFORCEMENT IS NOT REQUIRED FULLY
GROUT CELLS
DESIGN
PRESSURE 1ST
COURSE
REINF
2ND
COURSE
REINF
8" WALL
LINTEL
OR SILL
DEPTH
12" WALL
LINTEL
OR SILL
DEPTH
BOND BEAM WITH REINFORCEMENT
SEE SCHEDULE AT FIRST COURSE
3" MAXIMUM TO CL
VERTICAL REINFORCEMENT
SEE SCHEDULE
10" WALL
LINTEL
OR SILL
DEPTH
NOTES:
1.SEE NOTE 1 OF TYPICAL CMU NON-BEARING WALL REINFORCEMENT SCHEDULE FOR DESIGN
PRESSURE TO BE USED. FOR SEISMIC DESIGN CATEGORY D, E AND F UP TO Sds VALUE
SCHEDULED, USE 30 PSF DESIGN PRESSURE
2. MASONRY LINTELS SHALL BE SHORED DURING CONSTRUCTION AND SHALL REMAIN SHORED
UNTIL MASONRY HAS GAINED 100% OF FULL SPECIFIED STRENGTH (f'm)
3. DESIGN BASED ON DESIGN SERVICE LOAD PRESSURE NOTED
4. SEE TYPICAL CMU NON-BEARING WALL ELEVATIONS FOR ADDITIONAL INFORMATION INCLUDING
HORIZONTAL REINFORCEMENT. PROVIDE #5 (VERT.) AT 16" OC WITHIN LINTEL AND ABOVE.
5. FOR 6" WALLS WITH 30 PSF DESIGN PRESSURE, PROVIDE 3 BOND BEAM COURSES WITH 2-#5
IN EACH COURSE
6. PROVIDE LEVEL B SPECIAL INSPECTION CONFORMNG TO TABLE 1.19.2 OF ACI-530-11.
7. PROVIDE ADDITIONAL 2#6X26'-0" LONG AS SECOND LAYER IN FIRST COURSE OF LINTEL BEAM.
8. REFER TO S-611 FOR TYPICAL CMU JAMB AND PIER SCHEDULE. FOR STORE FRONT, USE THIS
TABLE FOR JAMB ZONE WIDTH WITH #5 (VERT.) IN EACH CELL AND FULLY GROUTED. REFER TO
FOUNDATION PLAN FOR PIERS TO BE FULLY GROUTED.
9. EXTEND LINTEL BEAM REBARS 54" BEYOND OPENING OR HOOK AT CMU WALL CONTROL JOINT.
10. THE IRST COURSE IS PLACE ABOVE BOTTOM HSS 8X8. LINTEL SCHEDULE1ST
COURSE
REINF
2ND
COURSE
REINF
1ST
COURSE
REINF
2ND
COURSE
REINF
1ST
COURSE
REINF
2ND
COURSE
REINF
SILLSCHEDULEBOND BEAM WITH REINFORCEMENT
SEE SCHEDULE AT FIRST COURSE
BOND BEAM AT SECOND COURSE WITH
REINFORCEMENT. SEE SCHEDULE
(SIMILAR WHERE 3RD COURSE IS
REQUIRED)
TYPICAL MASONRY SECTION AT OPENING
84'-0"
167'-0"
2412'-0"
10 PSF
2-#4
2-#4
2-#5
-
-
2-#4
8
16
24
2-#5
2-#4
2-#6
-
-
2-#4
16
16
32
2-#4
2-#6
2-#6
-
-
2-#4
8
16
32
2-#6
2-#5
2-#6
-
-
2-#4
84'-0"
167'-0"
4012'-0"
30 PSF
2-#4
2-#5
2-#6
-
2-#4
2-#6
8
16
40
2-#5
2-#6
2-#6
-
-
2-#6
16
24
48
2-#4
2-#6
2-#6
-
-
2-#6
8
16
40
2-#6
2-#6
2-#6
-
-
2-#6
812'-0"10 PSF 2-#4 -8 2-#4 -8 2-#4 -8 2-#4 -
87'-0"
2412'-0"
30 PSF
2-#5
2-#5
-
2-#5 (NOTE 5)
8
16
2-#5
2-#6
-
2-#6
8
16
2-#5
2-#5
-
2-#5
8
16
2-#5
2-#5
-
2-#5
BOTTOM SHELL3/4" CLEAR TO3 1/8"SEE SCHEDULELINTEL DEPTHOPENINGSEE SCHEDULESILL DEPTHGRAVITY
LOADED
LINTEL AT
STORE
FRONT
27'-8"64
2-#6 2-#6---------26'-4"56
2-#6 2-#6---------
REMARKS
FULLY GROUTED
AND SEE NOTE 6
LINTEL
MARK
L-1
L-2
36'-7 3/8"80 2-#6 2-#6---------L-3 FULLY GROUTED AND
SEE NOTE 6 AND 7
ADDITIONAL REINF.
PER NOTE 7.
JAMB ZONE
WIDTH (8)
24"
40"
40'-0"64 2-#6 2-#6---------L-4 FULLY GROUTED AND
SEE NOTE 6 AND 10 -
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
MASONRY TYPICAL DETAILS II
S6.02
TT
01.17.2018
NOT TO SCALE
TYPICAL CMU SILL AND LINTEL SCHEDULE (NON-BEARING WALL)1
A B
WALL
THICKNESS
t
MAXIMUM
WALL HEIGHT
'H'
5 PSF 10 PSF 30 PSF
12'-0"
14'-6"
17'-0"
19'-0"
8"
MAX CLEAR
MASONRY
OPENING
(SEE NOTE 4)
PIER ZONE
LENGTH
(NOTE 2)
WALL REINF
EACH CELL
16"4'-0"
7'-0"
12'-0"
16"
16"
#4
#4
#4
16"4'-0"
7'-0"
12'-0"
16"
16"/24"
#4
#4
#4
16"4'-0"
7'-0"
12'-0"
16"
16"/24"
#4
#4
#4
16"4'-0"
7'-0"
12'-0"
16"
16"/24"
#4
#4
#4
WALL REINF
EACH CELL
16"
16"
16"
#4
#4
#4
16"
16"
16"/24"
#4
#4
#4
16"
16"
24"
#4
#4
#4
16"
24"
40"
#4
#4
#4
WALL REINF
EACH CELL
16"
24"
40"
#4
#4
#4
24"
40"
56"
#4
#4
#4
32"
40"
64"
# 5
# 5
# 5
32"
40"
64"
# 6
# 6
# 6
NOTES:
1.SEE NOTE 1 OF TYPICAL CMU NON-BEARING WALL REINFORCEMENT SCHEDULE FOR DESIGN
PRESSURE TO BE USED. FOR SEISMIC DESIGN CATEGORY D, E, AND F UP TO Sds VALUE
SCHEDULED, USE 30 PSF DESIGN PRESSURE
2.SINGLE NUMBER FOR PIER REFERS TO PIER ZONE LENGTH. WHEN PIER WIDTH IS DENOTED
AS ##/##, PROVIDE PIER AS FOLLOWS:
EX 16"/24"
3. PROVIDE FULLY GROUTED JAMB AND PIER WITH VERTICAL BARS(S) IN EACH CELL OVER FULL
WIDTH AS SCHEDULED. SEE TYPICAL CMU NON-BEARING WALL REINFORCEMENT SCHEDULE
FOR REINFORCEMENT LAYOUT
4.FOR PIER ZONE SCHEDULE USE MAXIMUM CLEAR MASONRY OPENING AT LEAST EQUAL TO
AVERAGE WIDTH OF ADJACENT OPENINGS
5.SEE TYPICAL CMU NON-BEARING WALL PLAN DETAIL AT ADJACENT WALL OPENINGS
FOR ADDITIONAL INFORMATION
6.NOTIFY ENGINEER OF RECORD IF JAMB AND/OR PIER WIDTH NOTED CANNOT BE SATISFIED
7.AT PIERS WIDER THAN REQUIRED PER SCHEDULE, IT IS ACCEPTABLE TO REINFORCE EDGES
AS JAMB ZONES
JAMB ZONE
WIDTH
W1 OR W2
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
8"
16"
JAMB ZONE
WIDTH
W1 OR W2
8"
8"
8"
8"
8"
16"
8"
16"
16"
16"
16"
24"
PIER ZONE
LENGTH
(NOTE 2)
JAMB ZONE
WIDTH
W1 OR W2
16"
16"
24"
16"
24"
32"
16"
24"
40"
16"
24"
40"
PIER ZONE
LENGTH
(NOTE 2)
MINIMUM TOTAL PIER WIDTH, PW, INCLUDING ANY NON-CONTINUOUS CELLS
INTERRUPTED BY LINTELS
MINIMUM PIER ZONE WIDTH WITH CONTINUOUS VERTICAL BARS FULL HEIGHT
OF WALL
NOTE:
1. AT CONTINUOUS WALL INTERSECTIONS, SEE TYPICAL PLAN DETAIL
AT MASONRY WALL WITH INTERLOCKED INTERSECTIONS FOR BRACE
SPACING REQUIREMENTS
SEISMIC
DESIGN
CATEGORY
IMPORTANCE
FACTOR
WALL
HEIGHT
(FT)
CONNECTION
TYPE
A 1.0/1.5 ALL 1
B, C 1.5 ≤ 14.5 1
B, C 1.5 > 14.5 2
D, E, F 1.0 / 1.5 ≤ 14.5 1
D, E, F 1.0 / 1.5 > 14.5 2
Ip
CONNECTION LEGEND
B, C 1.0 ALL 1
SEE TYPICAL CMU NON-BEARING
WALL ELEVATIONS FOR INFORMATION
PARTIAL HEIGHT COURSE
WHERE REQUIRED
WALL BRACING BEAM
BETWEEN ROOF
BEAMS SEE PLAN
ROOF DECK
SEE PLAN
BENT PLATE 3/8" X 4" X 1'-0" LONG
EACH SIDE STAGGERED
3/16
3/163" EACH
END OF
ANGLE
2' - 0" 2' - 0"
4' - 0"
TYPICAL
1' - 0"BOTTOM
FLANGE OF
BEAM
BENT PLATE
ALTERNATE SIDE WITH
VERTICAL LEG
FLAT PLATE
L4X4X3/8 X 1'-0" LONG AT 4'-0" OC
SEE NOTE 1
SEE TYPICAL CMU NON-BEARING
WALL ELEVATIONS FOR INFORMATION1"1" MINIMUM CLEAR
(-0", +1/2")
1/8 4"
1/8 4"
1/4" DIA HILTI KWIK-PRO
SELF DRILLING SCREWS
ROOF DECK
20 GAGE MINIMUM
SEE PLAN
PLATE 3/16" X 2'-10" X 2'-2"
L4X4
WALL NOT
SHOWN FOR
CLARITY
CL LOW DECK FLUTE
TYPICAL
(6) SCREWS PER FLUTE
MINIMUM FIVE FLUTES.
EQUALLY SPACED SCREWS
ON EACH SIDE OF ANGLES AT
CONFLICT1"5 EQUAL SPACES2' - 10"
CMU TO ROOF DECK CONNECTION - TYPE 2CMU TO ROOF DECK CONNECTION - TYPE 1
PARTIAL HEIGHT COURSE
WHERE REQUIRED
A DETAIL B DETAIL
VERTICAL
REINFORCEMENT
SEE SCHEDULE
JAMB OR PIER WIDTH
SEE SCHEDULE
FILL SOLID WITH GROUT
VERTICAL REINFORCEMENT
TO BE PROVIDED IN EACH CELL
PROVIDE X"
ISOLATION JOINT
FIRST TOP BRACE TO BE
LOCATED AT ENDS OF WALL
TYPICAL
1' - 3 5/8"
VERTICAL REINFORCEMENT
AT EACH WALL END,
TYPICAL
SEE SCHEDULE
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
MASONRY TYPICAL DETAILS III
S6.03
TT
01.17.2018
NOT TO SCALE
TYPICAL CMU NON-BEARING WALL JAMB AND PIER ZONE SCHEDULE1
NOT TO SCALE
TYPICAL TOP BRACE DETAIL AT INTERIOR CMU WALL TO UNDERSIDE OF ROOF DECK - FLUTES PARALLEL2
1" = 1'-0"
TYPICAL PLAN DETAIL AT FULL HEIGHT MASONRY WALL
JOINT INTERSECTION3
3
4
3
4
2
1
DUCT OPENING
SEE MECHANICAL DRAWINGS
SIZE NEAREST TO BLOCK
MODULE
NO CONTROL JOINTS ARE TO BE
LOCATED AT OPENING CORNERS
TYPICAL
STEEL OR
PRECAST LINTEL
VERTICAL IN FIRST CELL AT
ALL OPENINGS TO
UNDERSIDE OF LINTEL
VERTICAL IN SECOND CELL AT
ALL OPENINGS FULL HEIGHT
VERTICAL IN FIRST CELL
OF LINTEL AT OPENING
TYPICAL
VERTICAL REINFORCEMENT IN FIRST
CELL AT ALL ENDS, INTERSECTIONS,
CONTROL JOINTS OR CORNERS
SEE SCHEDULE
TYPICAL WALL REINFORCEMENT
SEE TYPICAL CMU NON-BEARING WALL
REINFORCEMENT SCHEDULE
SEE CMU SILL AND
LINTEL SCHEDULE
FOR
REINFORCEMENT
DOWELS
SEE BASE OF WALL
DETAILS
3" MAXIMUM
(3/4" CLEAR
MINIMUM TO
BOTTOM SHELL)
SEE TYPICAL CMU SILL AND
LINTEL SCHEDULE (NON-BEARING
WALL) FOR REINFORCEMENT
SEE TYPICAL CMU NON-BEARING
WALL JAMB AND PIER ZONE
SCHEDULE FOR REINFORCEMENT
IN JAMB AND PIER ZONES
NOTES:
1. FOR WALL OPENING LIMITATIONS SEE TYPICAL CMU
NON-BEARING WALL PLAN DETAIL AT ADJACENT WALL
OPENINGS
2. FOR JAMB AND PIER ZONE CRITERIA SEE TYPICAL
CMU NON-BEARING WALL PLAN DETAIL AT ADJACENT
WALL OPENINGS
DISTANCE TO 1ST TYPICAL WALL BAR
SHALL NOT EXCEED 1/2 SCHEDULED
BAR SPACING AWAY FROM JAMB
ZONE
DISTANCE TO 1ST TYPICAL WALL BAR
SHALL NOT EXCEED 1/2 SCHEDULED
BAR SPACING AWAY FROM JAMB ZONE
T/WALL
T/SLAB
STEEL OR
PRECAST
LINTEL
SEE LINTEL SCHEDULE AND NOTE 1
OPENING LENGTH L1
SEE TYPICAL TOP BRACE DETAILS
FOR TOP OF WALL CONNECTIONS
END OF
WALL
3. MAXIMUM PIER HEIGHT SHALL NOT EXCEED 5 TIMES PIER WIDTH.
FOR PIER HEIGHTS EXCEEDING THIS CRITERIA PIER WIDTH SHALL
BE INCREASED SUCH THAT PIER WIDTH ≥ PIER HEIGHT/5WALL HEIGHTJOINT
CONTROL 2'-0" MINIMUM
.PIER HEIGHT (NOTE 3)TYPICAL
8" LINTEL BEARING
SEE LINTEL SCHED & NOTE 1
OPENING LENGTH L2
TYPICAL, 2'-0" MINIMUM
TENSION EMBED
MAXIMUM
1/2 TYPICAL SPACING
8"
SEE NOTE 2
JAMB ZONEMAXIMUM
1/2 TYPICAL
SPACING
SEE NOTE 2
JAMB ZONE 8"
8"
SEE NOTE 2
PIER ZONE 8"
PIER WIDTH
TYPICAL
2'-0" MIN BETWEEN OPENINGS
2'-0" MINIMUMTENSION EMBEDSILL REINFORCEMENT
PER TYPICAL CMU SILL
AND LINTEL SCHEDULE
(NON-BEARING WALL)
2#4 AT T/WALL
BOND BEAM
TYPICAL, UON
NO CONTROL JOINTS
ARE TO BE LOCATED
AT OPENING CORNERS,
TYPICAL
VERTICAL IN FIRST CELL AT
ALL OPENINGS FULL
HEIGHT
SEE SCHEDULE
VERTICAL IN FIRST CELL
OF LINTEL AT OPENING
TYPICAL
NOTES:
1. FOR WALL INFORMATION NOT SHOWN, SEE TYPICAL CMU NON-
BEARING WALL ELEVATION WITH STEEL OR PRECAST LINTELS
2. SEE TYPICAL CMU SILL AND LINTEL SCHEDULE (NON-BEARING
WALL)FOR ADDITIONAL INFORMATION
DOWELS
SEE BASE OF WALL DETAILS
3" MAXIMUM AT CMU
LINTEL
(3/4" CLEAR MINIMUM TO
BOTTOM SHELL)
LINTEL
UNITS
SEE TYPICAL CMU NON-BEARING
WALL PLAN DETAIL AT ADJACENT
WALL OPENINGS FOR JAMB AND
PIER ZONE CRITERIA
SEE TYPICAL CMU SILL
AND LINTEL SCHEDULE
(NON-BEARING WALL)
FOR REINFORCEMENT
T/WALL
T/SLABPIER HEIGHTWALL HEIGHT "H".OPENING LENGTH L1 OPENING LENGTH L2
JAMB ZONE PIER ZONE
PIER WIDTH
PW
NOTES:
1.SEE ARCHITECTURAL DRAWINGS FOR THE EXACT LOCATION OF MASONRY WALL OPENINGS
2.SUM OF OPENING WIDTHS L1 PLUS L2 ON EITHER SIDE OF PIER SHALL NOT EXCEED 24'-0", AND ANY
INDIVIDUAL OPENING SHALL NOT EXCEED 12'-0" IN WIDTH. FOR CONDITIONS EXCEEDING THIS CRITERIA,
ENGINEER OF RECORD SHALL BE NOTIFIED PRIOR TO CONSTRUCTION
3.W1 AND W2 REFERS TO WIDTH OF JAMB ZONE BASED ON ADJACENT CLEAR OPENING L1 AND L2,
RESPECTIVELY AS PER TYPICAL CMU NON-BEARING WALL JAMB AND PIER ZONE SCHEDULE
4. PIER ZONE REFERS TO MINIMUM WIDTH OF PIER AS SCHEDULED ON TYPICAL CMU NON-BEARING
WALL JAMB AND PIER ZONE SCHEDULE
5.SEE TYPICAL CMU NON-BEARING WALL JAMB AND PIER ZONE SCHEDULE FOR REINFORCEMENT
BARS AT EACH CELL
IN JAMB ZONE
BARS AT EACH CELL
IN PIER ZONE
BARS AT EACH CELL
IN JAMB ZONE
SEE NOTE 3
JAMB ZONE W1
CLEAR OPENING
L1
SEE NOTE 4
PIER ZONE = PIER WIDTH
CLEAR OPENING
L2
CMU WALL WITH CMU LINTEL
CMU WALL WITH STEEL OR PRECAST LINTEL
SEE NOTE 3
JAMB ZONE W2
BAR AT LINTEL
BEARING CELL
BARS AT EACH CELL
IN PIER ZONE
BARS AT EACH CELL
IN JAMB ZONE
BAR AT LINTEL
BEARING CELL
BAR AT LINTEL
BEARING CELL
SEE NOTE 3
JAMB ZONE W1
CLEAR OPENING
L1
SEE NOTE 4
PIER ZONE
PIER WIDTH
CLEAR OPENING
L2
SEE NOTE 3
JAMB ZONE W2
NOTE:
1. SEE TYPICAL CMU SILL AND LINTEL SCHEDULE (NON-BEARING WALL)
AND/OR TYPICAL STEEL LINTEL SCHEDULE (NON-BEARING WALL) FOR
ADDITIONAL INFORMATION
T/SLAB
T/WALL
OPENINGPROVIDE
HORIZONTAL
REINFORCEMENT
IN TOP JOINT
BOND BEAM
PREMOLDED EXPANSION JOINT
MATERIAL 1"
TYPICAL
TYPICAL VERTICAL
REINFORCEMENT
SEE SCHEDULE
SEE TYPICAL WALL
ELEVATIONS FOR
CRITERIA
SEE PLAN AND TYPICAL
DETAILS FOR SLAB
REINFORCEMENT
SEE TYPICAL
TOP BRACE DETAILS
BOTTOM OF SUPPORT
SEE PLAN
GROUT TOP COURSE SOLID
PROVIDE
HORIZONTAL
REINFORCEMENT
IN FIRST COURSE
TYPICAL HORIZONTAL
REINFORCEMENT
SEE SCHEDULE
SEE NOTE 1
SEE TYPICAL BASE
OF WALL DETAILS
SEE NOTE 1
OPENINGWALL WITH
CMU LINTEL
NEW YORK CITY WASHINGTON, DC PRINCETON DURHAM TORONTO
WWW.LORINGENGINEERS.COM
LORING NO. 9906
300 ALEXANDER PARK, STE 310PRINCETON, NJ 08540
TEL (609) 716-6160
FAX (609) 716-6162
ikon.5
864 Mapleton Road
Princeton, NJ 08540
609.919.0099
fax 609.919.0088
a r c h i t e c t s
www.ikon5architects.com
T.G. MILLER, P.C.
ENGINEERS AND SURVEYORS
203 NORTH AURORA STREET
ITHACA, NEW YORK 14850
WWW.TGMILLERPC.COM
607-272-6477
DRAWING NO.:
DRAWN BY:
DATE:
SHEET TITLE:
PROJECT TITLE:
PROFESSIONAL LICENSE
NUMBER
VERSIONS
NO.DATE DESCRIPTION
238 LINDEN
AVENUE
ITHACA, NY
LANDSCAPE ARCHITECT:
FIRE PROTECTION, PLUMBING,
MECHANICAL, ELECTRICAL
ENGINEER:
STRUCTURAL ENGINEER:
CIVIL ENGINEER:
ARCHITECT:
1 01.17.2018
CONSTRUCTION
DOCUMENTS
MASONRY TYPICAL DETAILS IV
S6.04
TT
01.17.2018
NOT TO SCALE
TYPICAL CMU NON-BEARING WALL ELEVATION WITH STEEL OR PRECAST LINTELS1 NOT TO SCALE
TYPICAL CMU NON-BEARING WALL ELEVATION WITH CMU LINTELS2
1" = 1'-0"
TYPICAL CMU NON-BEARING WALL PLAN DETAIL AT ADJACENT WALL OPENINGS3 NOT TO SCALE
TYPICAL CMU NON-BEARING WALL SECTION4