Loading...
HomeMy WebLinkAboutBCU 2021-Package B-Myron Taylor1REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 PACKAGE B TITLE SHEET & DRAWING LIST T-000B 190306 RFG BMA 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor HallBUILDING CONTROLS UPGRADE 2021 PACKAGE B -BUILDING 2021 MYRON TAYLOR HALL HVAC DRAWINGS H-000B GENERAL NOTES, SYMBOLS LIST - HVAC H-100B PARTIAL BASEMENT FLOOR PLAN - DEMOLITION - HVAC H-101B PARTIAL GROUND FLOOR PLAN - DEMOLITION - HVAC H-102B PARTIAL FIRST FLOOR PLAN - DEMOLITION - HVAC H-103B PARTIAL SECOND FLOOR PLAN - DEMOLITION - HVAC H-104B PARTIAL THIRD FLOOR PLAN - DEMOLITION - HVAC H-105B PARTIAL FOURTH FLOOR PLAN - DEMOLITION - HVAC H-106B PARTIAL ROOF FLOOR PLAN - DEMOLITION - HVAC H-200B PARTIAL BASEMENT FLOOR PLAN - NEW WORK - HVAC H-201B PARTIAL GROUND FLOOR PLAN - NEW WORK - HVAC H-202B PARTIAL FIRST FLOOR PLAN - NEW WORK - HVAC H-203B PARTIAL SECOND FLOOR PLAN - NEW WORK - HVAC H-204B PARTIAL THIRD FLOOR PLAN - NEW WORK - HVAC H-205B PARTIAL FOURTH FLOOR PLAN - NEW WORK - HVAC H-206B PARTIAL ROOF FLOOR PLAN - NEW WORK - HVAC H-300B SECTIONS - NEW WORK - HVAC H-400B AIRFLOW DIAGRAM - HVAC H-500B CONTROL SCHEMATIC & SYSTEM SUMMARY H-501B CONTROL SCHEMATIC & SYSTEM SUMMARY H-502B CONTROL SCHEMATIC & SYSTEM SUMMARY H-503B CONTROL SCHEMATIC & SYSTEM SUMMARY H-504B CONTROL SCHEMATIC & SYSTEM SUMMARY H-505B CONTROL SCHEMATIC & SYSTEM SUMMARY TITLESHEET T-000B PACKAGE B TITLE SHEET & DRAWING LIST ELEC DRAWINGS E-000B GENERAL NOTES, SYMBOLS LIST - ELEC E-100B PARTIAL FOURTH FLOOR PLAN - DEMOLITION - ELECTRICAL E-200B PARTIAL THIRD FLOOR PLAN - NEW WORK - ELECTRICAL E-201B PARTIAL FOURTH FLOOR PLAN - NEW WORK - ELECTRICAL Cornell University ---COURT YARD ---OPEN TO BELOW ---OPEN TO BELOW ---OPEN TO BELOW 1854182 15010022 72180 53182A6210059 2210076 18111868510058 13110057 15110029 114186A 26710066 42991842303181 2910023 28184A 28184B 3110028 12410010 2610074 2210061 710069 3051000717610035 3510037 13719011610012 2210042 UP DN DN UP UP UP DN UP DN UP UP UP UP DN UP UP DN DN UP UP UP UP DN DN DN DN DSD MBH THOUSAND BTU/HOUR (E)EXISTING DOUBLE LINE RECTANGULAR DUCT CONTINUED FPM FEET PER MINUTE AIR FLOW AFF ABOVE FINISHED FLOOR PIPE ANCHOR G.C.GENERAL CONTRACTOR PIPE GUIDE E.C.ELECTRICAL CONTRACTOR EXPANSION COMPENSATOR WITH GUIDES N.C.NORMALLY CLOSED PRE-FAB EXPANSION LOOP TEMPERATURE SENSOR STRAINER PRESSURE GAUGE THERMOMETER UNION 24x12DN UP AIR VENTV24x1214x8 6" BOOT TAP TT THERMOSTATIC TRAP 14"18"LATERAL FT FLOAT & THERMOSTATIC TRAP SUPPLY DIFFUSER, REGISTER OR GRILLE TD THERMODYNAMIC TRAP FLEXIBLE DUCTWORK BT BUCKET TRAP COMPRESSED AIRA DIRECTION OF FLOW BBD BOILER BLOW DOWN CONDENSER WATER SUPPLYCS CR CONDENSER WATER RETURN CWS CHILLED WATER SUPPLY CWR CHILLED WATER RETURN D DRAIN FUEL OIL FILLFOF FUEL OIL GAUGEFOG FOS FUEL OIL SUPPLY FOR FUEL OIL RETURN FOV FUEL OIL TANK VENT G GAS GLYCOL SUPPLYGS GLYCOL RETURNGR HPWS HEAT PUMP WATER SUPPLY HPWR HEAT PUMP WATER RETURN HWS HOT WATER SUPPLY HWR HOT WATER RETURN HG HOT GAS LPS LOW PRESSURE STEAM LPC LOW PRESSURE CONDENSATE MPS MEDIUM PRESSURE STEAM MPC MEDIUM PRESSURE CONDENSATE HPS HIGH PRESSURE STEAM HPC HIGH PRESSURE CONDENSATE PC PUMPED CONDENSATE RD REFRIGERANT DISCHARGE RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION VAC VACUUM CW DOMESTIC COLD WATER EXISTING WORK TO BE REMOVED DOUBLE LINE PIPE OR ROUND DUCT CONTINUED E PNEUMATIC THERMOSTAT NTS NOT TO SCALE (DBL)DOUBLE WALL LINED DUCT CFM CUBIC FEET PER MINUTE AD ACCESS DOOR P.C.PLUMBING CONTRACTOR N.O. NORMALLY OPEN DUCT SMOKE DETECTOR HUMIDISTAT ROUND DUCT - IN INCHES12" 24x12DN UP 14" CONICAL TEE18"VOLUME DAMPER CAP OR PLUG ELBOW DOWN ELBOW UP AAD AUTOMATIC AIR DAMPER FD FIRE DAMPER SD SMOKE DAMPER BDD BACK DRAFT DAMPER M MOTORIZED DAMPER BALL VALVE GATE VALVE CHECK VALVE BALANCING VALVE BUTTERFLY VALVE PRESSURE REDUCING VALVEPRV CONTROL VALVE PRESSURE/TEMPERATURE TEST PLUG (L) (2L)ACOUSTIC THERMAL LINING - 2" THICK M.C.MECHANICAL CONTRACTOR W/W WALL TO WALL G THERMOSTAT/SENSOR WITH GUARDG DUCT SECTION - SUPPLY DUCT SECTION - RETURN WIDTH A x DEPTH B A B R D 24x1214" 6" BOOT TAP BG BLAST GATE FIN TUBE RADIATION VALANCE A B C REGISTER, GRILLE OR DIFFUSER TAG A = TYPE B = NECK SIZE C = CFM B C D FIN TUBE RADIATION TAG FT-A = TYPE B = FIN TUBE LENGTH C = ENCLOSURE LENGTH D = GPM FT-A A B C D VALANCE TAG A = TYPE B = COIL SIZE C = COOLING GPM D = HEATING GPM POINT OF CONNECTION POINT OF DISCONNECTION BOTTOM TAP TRIPLE DUTY VALVETD GLOBE VALVE THREE WAY CONTROL VALVE SUCTION DIFFUSERSD DRAIN VALVE WITH HOSE CONNECTION, CAP AND CHAIN FC FLEX CONNECTOR - DUCTWORK FLEXIBLE CONNECTOR - PIPING AIR TERMINAL UNIT AND TAG (OPTION 1) A B C AIR TERMINAL UNIT TAG (OPTION 2) A = UNIT NO. B = MAXIMUM CFM C = MINIMUM CFM AxB FO DUCT SECTION - FLAT OVAL (FO) V VENT REDUCER S H S ACOUSTIC THERMAL LINING - 1-1/2" THICK EXHAUST GRILLE RETURN REGISTER SINGLE LINE PIPE CONTINUED TRANSITION SQUARE TO ROUND RISE IN DUCT - IN DIRECTION OF AIRFLOW DROP IN DUCT - IN DIRECTION OF AIRFLOW SUPPLY DUCT TURNING UP OR DOWN RETURN DUCT TURNING UP OR DOWN SUPPLY/RETURN RECTANGULAR MAIN RECTANGULAR BRANCH SUPPLY/RETURN RECTANGULAR MAIN ROUND BRANCH SUPPLY/RETURN ROUND MAIN ROUND BRANCH SUPPLY/RETURN ROUND MAIN ROUND BRANCH MITERED ELBOW WITH TURNING VANES DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL T RELIEF VALVE T HVAC SYMBOL LIST X X DRAWING KEYNOTE DEMOLITION KEYNOTE A B C RADIANT CEILING PANEL TAG A = TYPE B = LENGTH C = GPM CARBON DIOXIDE SENSORC CARBON MONOXIDE SENSORCO GAS SENSORG SYMBOL DESCRIPTION SYMBOL DESCRIPTION AVERAGING SENSOR SS START/STOP OC OPEN/CLOSE ED ENABLE/DISABLE T TEMPERATURE SENSOR (DUCT OR PIPE MOUNTED) H HUMIDITY SENSOR (DUCT MOUNTED) I P ELECTRICAL INTERFACE AUTOMATIC AIR DAMPER (PARALLEL BLADE) AUTOMATIC AIR DAMPER (OPPOSED BLADE) E ELECTRIC/ELECTRONIC CONTROL VALVE (3-WAY) E ES END SWITCH EA EXHAUST AIR MOISTURE SENSOR OCCUPANCY SENSOR FLOW METER SUPPLY FANSF BTU ENERGY METERBTU P DIFFERENTIAL STATIC PRESSURE SWITCH ALARM STATUS PROBE SENSOR RELAY FREEZE-STATFZ E ELECTRIC ACTUATOR CURRENT TRANSDUCER FLOW SENSOR AIR FLOW MEASURING STATION HARD WIRE INTERFACE S SOLENOID VALVE S M MANUAL SWITCH THERMOSTATIC EXPANSION VALVE CARBON DIOXIDE SENSOR (DUCT MOUNTED) CO 2 BINARY POINT ANALOG POINT THERMOWELL P DIFFERENTIAL STATIC PRESSURE TRANSMITTER CONTROLS SCHEMATIC SYMBOL LIST ASD ADJUSTABLE SPEED DRIVE R134a REFRIGERANT R134a SENSOR (WALL MOUNTED) C C COOLING COIL BASE MOUNTED PUMP FILTER BANK RETURN AIR FANRF EF EXHAUST AIR FAN H C HEATING COIL SMOKE CONTROL FANSC HUMIDIFIER DISPERSION GRID EP ELECTRIC/PNEUMATIC SWITCH OR RELAY PE PNEUMATIC/ELECTRIC SWITCH OR RELAY F FLOW TRANSMITTER P PRESSURE TRANSMITTER ELECTRIC/PNEUMATIC TRANSDUCER I E ELECTRONIC/ELECTRIC TRANSDUCER PNEUMATIC CONTROL VALVE (3-WAY) PNEUMATIC CONTROL VALVE (2-WAY) ELECTRIC/ELECTRONIC CONTROL VALVE (2-WAY) PNEUMATIC ACTUATOR MAIN TEMPERATURE CONTROL AIR SOURCEA IN LINE PUMP HR C HEAT RECOVERY COIL AIR TERMINAL UNIT WITH FACTORY ATTENUATOR (OPTION 1) VAV-X-XX VAV-X-XX LAB AIR VALVE RADIANT CEILING PANEL FLOW SWITCH VARIABLE FREQUENCY DRIVE G B GAS BURNER P PRESSURE SWITCH HUMIDIFIERH A R S OS M FS F BUTTERFLY CONTROL DAMPER VFD OA OUTSIDE AIR RA RETURN AIR SA SUPPLY AIR CARBON MONOXIDE SENSOR (DUCT MOUNTED) CO F.L. FAIL LAST DEWPOINT SENSOR (DUCT MOUNTED) DP C CONDENSATE SENSOR STATIC PRESSURE SENSOR (DUCT MOUNTED) SP CT BI BINARY INPUT BO BINARY OUTPUT AI ANALOG INPUT AO ANALOG OUTPUT BV BINARY VALUE AV ANALOG VALUE HIGH LEVEL SWITCHHI LOW LOW LEVEL SWITCH VENTURI AIRFLOW CONTROL VALVE TRANSFORMER MOTOR STARTERMS ROTATION DETECTORRD SMOKE DETECTORSD MOD MODULATING ELECTRIC TO PNEUMATIC TRANSDUCEREP SPEED COMMANDSC AOM ADDRESSABLE OUTPUT MODULE (FIRE ALARM INTERFACE) COM NETWORK COMMUNICATION INTERFACE POINT SIGNAL OUT CURRENT SENSORCS SIGNAL OUT A SIGNAL IN AIR IN A SIGNAL IN ELECTRIC TO PNEUMATIC SWITCH LINE VOLTAGE THERMOSTAT T NITROGEN DIOXIDE SENSORN MOTOR S SPACE SENSOR WITH SETPOINT ADJUSTMENT SA S SPACE SENSOR WITH OCCUPANCY OVERRIDE S SPACE SENSOR WITH VISUAL DISPLAY S SPACE SENSOR WITH FAN ON/OFF SWITCH T ROOM TEMPERATURE SENSOR WITH SETPOINT ADJUSTMENT T T T ROOM TEMPERATURE SENSOR WITH OCCUPANCY OVERRIDE ROOM TEMPERATURE SENSOR WITH VISUAL DISPLAY ROOM TEMPERATURE SENSOR WITH FAN ON/OFF SWITCH DIGITAL INPUT (GENERAL)DI DO DIGITAL OUTPUT (GENERAL) ANALOG INPUT (GENERAL) ANALOG OUTPUT (GENERAL) AI AO LIQUID IMMERSION TEMPERATURE SENSOR T SINGLE POINT SENSOR M M OV D F SA OV D F F.O.FAIL OPEN RELATIVE HUMIDITY SENSORRH LOW LIMIT TEMPERATURE SWITCH FZ GENERAL NOTES: IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DISPOSE OF ALL DEMOLITION DEBRIS AND MATERIALS OFF SITE IN A PROPER LEGAL MANNER. THE CONTROL SYSTEM INDICATED TO BE REMOVED, SHALL BE ENTIRELY REMOVED AND REPLACED, INCLUDING THE CONTROL SYSTEM, CONTROL WIRING, PNEUMATIC TUBING AND ALL ASSOCIATED ACCESSORIES. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE ALL SHUTDOWNS OF AIR HANDLING, CHILLED WATER, HOT WATER, STEAM, ECT. SYSTEMS WITH CORNELL UNIVERSITY FACILITY PERSONNEL FOR TIE-IN CONNECTIONS. ALL SHUT DOWNS WILL OCCUR DURING NIGHTS OR WEEKENDS. THE CONTRACTOR SHALL ASSIST THE UNIVERSITY PERSONNEL IN SHUTTING DOWN, DRAINING, VENTING, ECT. OF SYSTEM TO FACILITATE THE INTENDED WORK. IT IS THE REQUIREMENT OF THE PROJECT THE CONSTRUCTION WORK BE PHASED TO FACILITATE MINIMUM IMPACT TO THE NORMAL OPERATION OF THE FACILITY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO THOROUGHLY REVIEW THE GENERAL CONDITIONS FOR THE PHASING REQUIREMENTS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE FOR ALL TEMPORARY SERVICES (SUPPLY AIR, RETURN AIR, EXHAUST AIR, CHILLED WATER, HOT WATER, STEAM, CONDENSATE, AND CONTROL SYSTEMS) TO FACILITY PHASING REQUIREMENTS WITHOUT INTERRUPTION OF THE HVAC SYSTEMS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE THE LOCATIONS OF ALL ROOM TEMPERATURE SENSORS AND OCCUPANCY WITH THE OWNER/ENGINEER. THE CONTRACTOR SHALL SCHEDULE A WALK THROUGH WITH THE OWNER/ENGINEER TO LOCATE SENSOR LOCATIONS PRIOR TO INSTALLATION. THE TEMPERATURE SENSORS SHALL BE INSTALLED IN ALIGNMENT WITH ELECTRICAL, FIRE, AND OTHER DEVICES WHEN LOCATED ON COMMON WALLS. THE OCCUPANCY SENSORS SHALL BE INSTALLED IN ORDER TO PROVIDE COMPLETE COVERAGE OF THE WORK AREAS. THE MOUNTING HEIGHT FOR ALL ROOM THERMOSTATS OR SENSORS SHALL BE 48 IN. TO TOP OF THE COVER. CONTRACT DOCUMENTS INDICATE REPLACEMENT OF ALL SENSORS, RELAYS, SAFETIES, ETC. IN ORDER TO ALIGN THE EXISTING SYSTEMS WITH CORNELL STANDARDS. CONTROL CONTRACTOR INSTALLING THE NEW CONTROL SYSTEMS SHALL INDICATE/REFLECT ANY EXISTING SENSORS WORKING CORRECTLY TO BE REUSED ON THE AS-BUILT DOCUMENTS. A. B. C. D. E. F. G. BLDG. 2021 BLDG. 2021ABLDG. 3028 NORTH REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 GENERAL NOTES, SYMBOLS LIST - HVAC H-000B 190306 RFG BMA 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor HallNTS A KEYPLAN UP UP ---COURT YARD ---OPEN TO BELOW ---OPEN TO BELOW ---OPEN TO BELOW 1854182 15010022 72180 53182A6210059 2210076 18111868510058 13110057 15110029 114186A 26710066 42991842303181 2910023 28184A 28184B 3110028 124100102610074 2210061 710069 3051000717610035 3510037 13719011610012 2210042 UP DN DN UP UP UPDN UP DN UP UP UP UP DN UP UP DN DN UP UP UP UP DN DN DN DN BLDG. 2021ABLDG. 3028BLDG. 3028 BLDG. 2021 BLDG. 2021A BLDG. 2021 B20 6,670 B20A 37 B20B 37 B0041 46 B0001 133 B0050 418 UTILITY TUNNEL --- B0006 70 B0067 26 B0025 119 B50 594 B0046 126B0064 41 B0065 39 B0045 168 B0066 34 B0021 166 B0020 163 B0063 610 B0060 478 B0042 349 (E)RHC-15 SS S TO (E)RHC-14 11 1 (E)28x7 (E)24x7 (E)18x7 (E)12x7 (E)6x7 (E)6x4 (E)6x4 TO (E)RHC-15(E)28x7TO (E)RHC-13 (E)20x7(E)20x7(E)16x7(E)16x7(E)10x7 (E)10x7 (E)26x7 (E)18x7(E)12x7 2 AHU-2/RHC-14 AHU-2/RHC-13 RAF-2 RAF-2 AHU-2/RHC-15 (E)10x6 (E)20x6 (E)12x6 (E)8x20 UP (E)12x6 (E)8x5 NORTH REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 PARTIAL BASEMENT FLOOR PLAN - DEMOLITION - HVAC H-100B 190306 RFG BMA 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor Hall1/8" = 1'-0" 1 PARTIAL BASEMENT FLOOR PLAN - SOUTH - DEMOLITION - HVAC DEMOLITION NOTES 1 DISCONNECT AND REMOVE EXISTING TEMPERATURE SENSOR, ASSOCIATED CONTROLS AND CONTROL ACCESSORIES. 2 DISCONNECT AND REMOVE EXISTING REHEAT COIL CONTROL VALVE. GENERAL NOTES A. CONTRACTOR SHALL DISCONNECT AND REMOVE 120V CONNECTION FROM EXISTING CONTROL PANELS AND EXTEND & REWORK AS REQUIRED TO NEW CONTROL PANELS. WIRING SHALL BE (2)#12AWG & (1)*12EG IN 3/4" CONDUIT. B. DISCONNECT AND REMOVE ALL PNEUMATIC (COMPRESSED AIR) TUBING/PIPING AND ACCESSORIES BACK TO MAIN AND CAP AIR TIGHT. IF MATERIAL IS POLY, PROVIDE BRASS PLUG. TERMINATING BY BENDING END OF TUBING OR TERMINATING WITH A SHEETMETAL SCREW IS NOT ACCEPTABLE. THERE SHALL BE NO DEAD END BRANCH COMPRESSED AIR TUBING/PIPING. NTS A KEYPLAN - H-100B UP DN UP UP UP DN UP UP ---COURT YARD ---OPEN TO BELOW ---OPEN TO BELOW ---OPEN TO BELOW 1854182 15010022 72180 53182A6210059 2210076 18111868510058 13110057 15110029 114186A 26710066 42991842303181 2910023 28184A 28184B 3110028 124100102610074 2210061 710069 3051000717610035 3510037 137190116100122210042 UP DN DN UP UP UP DN UP DN UP UP UP UP DN UP UP DN DN UP UP UP UP DN DN DN DN BLDG. 2021ABLDG. 3028BLDG. 3028 BLDG. 2021 BLDG. 2021A BLDG. 2021 G70A 2779 S S TO (E)RHC-11TO (E)RHC-10 S TO (E)RHC-9 S TO (E)RHC-12 1 1 1 (E)RHC-14 (E)RHC-13TO ROOM B20 (E)SENSOR TO ROOM B20 (E)SENSOR 2 2 (E)20x7 1 AHU-2/RHC-10 AHU-2/RHC-11 RAF-2 AHU-2/RHC-12 AHU-2/RHC-11 RAF-2AHU-2/RHC-9 (E)32x7(E)24x7 (E)20x7(E)12x7 (E)20x7(E)16x7(E)12x7 (E)12x7 (E)26x7(E)12x7 (E)20x7 (E)12x7 (E)12x7 (E)26x7 (E)20x7 (E)12x7 G0015 34G71 54 B0006 --- G0054 103 OPEN TO BELOW --- G0069 27 G0046 119 G0066 34 G0065 39 G30 --- G0051 --- G0063 --- G0003 --- G0045 168 G0020 163G0021 166 G0062 64 G0061 55 G25A 14 G25 358 G20 7,841 G0041 29 G0001 145 G0057 26 G0016 24 G70 4080 G0058 29 G60A 121 G60 245 G62 264 G62A 13 G0051 117 G0056 152 LOADING DOCK --- G65 1510 G0006 70 G0014 73 G0055 99 G80 435 G70B 435 G70C 6 G0072 15 G0068 24 (E)34x30 UP (E)8x12 UP (E)8x12 UP (E)6x16 UP(E)6x16 UP (E)16x5 (E)14x20 UP & (E)8x20 DN (E)8x8 (E)20x8 (E)12x6 (E)6x6 (E)12x6(E)12x6 (E)12x6 (E)6x8 (E)12x5 (E)12x5(E)12x5 (E)12x5 (E)12x5 (E)12x5 (E)12x5 (E)7x5 (E)7x5(E)7x5(E)7x5 NORTH REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 PARTIAL GROUND FLOOR PLAN - DEMOLITION - HVAC H-101B 190306 RFG BMA 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor Hall1/8" = 1'-0" 1 PARTIAL GROUND FLOOR PLAN - DEMOLITION - HVAC DEMOLITION NOTES 1 DISCONNECT AND REMOVE EXISTING TEMPERATURE SENSOR, ASSOCIATED CONTROLS AND CONTROL ACCESSORIES. 2 DISCONNECT AND REMOVE EXISTING REHEAT COIL CONTROL VALVE. GENERAL NOTES A. CONTRACTOR SHALL DISCONNECT AND REMOVE 120V CONNECTION FROM EXISTING CONTROL PANELS AND EXTEND & REWORK AS REQUIRED TO NEW CONTROL PANELS. WIRING SHALL BE (2)#12AWG & (1)*12EG IN 3/4" CONDUIT. B. DISCONNECT AND REMOVE ALL PNEUMATIC (COMPRESSED AIR) TUBING/PIPING AND ACCESSORIES BACK TO MAIN AND CAP AIR TIGHT. IF MATERIAL IS POLY, PROVIDE BRASS PLUG. TERMINATING BY BENDING END OF TUBING OR TERMINATING WITH A SHEETMETAL SCREW IS NOT ACCEPTABLE. THERE SHALL BE NO DEAD END BRANCH COMPRESSED AIR TUBING/PIPING. NTS A KEYPLAN - H-101B UP DN UP UP UP UP DN UP UP DN DN UP UP ---COURT YARD ---OPEN TO BELOW ---OPEN TO BELOW ---OPEN TO BELOW 1854182 15010022 72180 53182A6210059 2210076 18111868510058 13110057 15110029 114186A 26710066 42991842303181 2910023 28184A 28184B 3110028 124100102610074 2210061 710069 3051000717610035 3510037 13719011610012 2210042 UP DN DN UP UP UPDN UP DN UP UP UP UP DN UP UP DN DN UP UP UP UP DN DN DN DN BLDG. 2021ABLDG. 3028BLDG. 3028 BLDG. 2021 BLDG. 2021A BLDG. 2021 S TO (E)RHC-2 1 (E)RHC-10 (E)RHC-9 TO ROOM G20 (E)SENSOR TO ROOM G20 (E)SENSOR TO ROOM G20 (E)SENSOR TO ROOM G20 (E)SENSOR (E)RHC-12 (E)RHC-11 2 2 2 2 S S TO (E)RHC-5 S TO (E)RHC-7 S TO (E)RHC-4 1 1 1 1 TO (E)AHU-1 (E)FIN TUBE RADIATION (TYPICAL) 195 132 10067 113 197 98 194 2467 193 171 175 172 10055 19 10044 58 10051 219 S (E)36x12 (E)AHU-5 1 3 66 6 2S 1 S (E)20x10 (E)28x10 (E)36x10 (E)12x10 10032 1237 10026 279 10064 44 10011 237 179 60 10027 18610063 26 10065 16 170A 96 10079 41 10016 25 10040 512 10001 138 104 283103 176 107 158 109 104115 692 105 101 106 292 108A 8 104A 8 10043 1942 PLANTER ---10002 81 117 98 119 110121 121 123 33 120 233 122 232 124 277 130 --- 130C --- 130B --- 130A --- 132 --- 134 --- 136 --- 138 --- 140 --- 142 --- 133 --- 135 --- 137 --- 139 --- 141 --- 135A ---10048 --- 10047 --- 128 --- 130D --- 126 --- 129 --- 131 --- 127 --- 10003 --- 10065 ---125 --- 10039 --- 10021 166 10020 163 10045 169 10046 119 10066 34 10065 39 10062 62 10061 54 115A 68 118 232 116 233 114 232 112 251 110 229 108 252 10042 981 10049 439 162 209 161 134 160 320 165 386 FIREPLACE --- 10041 43 167 26 10052 6 10053 6 10006 278 10050 1269 EXTERIOR ROOF TERRACE --- 10014 64 10017 24 170 8439 10072 15 10015 34 10009 84 10056 6 122A 10 124A 10 118A 10 120A 10 114A 10 116A 10 112A 7 110A 7 (E)34x30 UP&DN (E)16x36 UP & (E)14x20 DN TO (E)RHC-17 (E)EF-6 7 (E)18x6 (E)16x6 66666 (E)14x6 (E)6x4 (E)6x4 (E)6x4(E)8x6(E)10x6 (E)12x6 (E)12x6 (E)8x6 (E)8x4 (E)16x6(E)20x6 (E)17x10 UP (E)17x10 UP (E)17x10 UP (E)17x10 UP (E)17x10 UP (E)17x10 UP (E)17x10 UP (E)17x10 UP (E)16x5 (E)12x5 (E)7x5 (E)12x5 (E)12x5 (E)16x5 (E)12x5 (E)7x5(E)7x5(E)7x5 (E)12x5 (E)12x5 (E)7x5 (E)7x5(E)7x5 (E)12x5(E)12x5 (E)7x5 (E)12x6(E)12x6 (E)6x4(E)6x4(E)6x4 (E)8x6 (E)20x10 (E)14x10 (E)7x10 (E)26x10 (E)36x12 (E)36x12 UP (E)36x10 (E)16x6 (E)12x6 (E)10x6 (E)10x6 (E)6x4(E)6x4 (E)6x4(E)6x4 (E)8x6 (E)6x6 (E)RHC-16 4 52 (E)RHC-17 1 AHU-4 AHU-4 124 277 124 277 (E)24x8 & (E)8x8 UP 8 NORTH REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 PARTIAL FIRST FLOOR PLAN - DEMOLITION - HVAC H-102B 190306 RFG BMA 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor Hall1/8" = 1'-0" 1 PARTIAL FIRST FLOOR PLAN - DEMOLITION - HVAC DEMOLITION NOTES 1 DISCONNECT AND REMOVE EXISTING TEMPERATURE SENSOR, ASSOCIATED CONTROLS AND CONTROL ACCESSORIES. 2 DISCONNECT AND REMOVE EXISTING REHEAT COIL CONTROL VALVE. 3 DISCONNECT AND REMOVE EXISTING CONTROLS AND CONTROL ACCESSORES ASSOCIATED WITH EXISTING AIR HANDLING UNIT. 4 DISCONNECT AND REMOVE EXISTING CHILLED WATER COIL CONTROL VALVE. 5 DISCONNECT AND REMOVE EXISTING GLYCOL PREHEAT COIL CONTROL VALVE. 6 DISCONNECT AND REMOVE EXISTING CONTROLS, CONTROL VALVE AND CONTROL ACCESSORIES ASSOCIATED WITH EXISTING FIN TUBE RADIATION. 7 DISCONNECT AND REMOVE EXISTING CONTROLS AND CONTROL ACCESSORIES ASSOCIATED WITH EXISTING TRANSFER AIR FAN. 8 DISCONNECT AND REMOVE EXISTING DAMPER ACTUATORS ASSOCIATED WITH THE EXISTING AIR HANDLING UNIT SYSTEM. GENERAL NOTES A. CONTRACTOR SHALL DISCONNECT AND REMOVE 120V CONNECTION FROM EXISTING CONTROL PANELS AND EXTEND & REWORK AS REQUIRED TO NEW CONTROL PANELS. WIRING SHALL BE (2)#12AWG & (1)*12EG IN 3/4" CONDUIT. B. DISCONNECT AND REMOVE ALL PNEUMATIC (COMPRESSED AIR) TUBING/PIPING AND ACCESSORIES BACK TO MAIN AND CAP AIR TIGHT. IF MATERIAL IS POLY, PROVIDE BRASS PLUG. TERMINATING BY BENDING END OF TUBING OR TERMINATING WITH A SHEETMETAL SCREW IS NOT ACCEPTABLE. THERE SHALL BE NO DEAD END BRANCH COMPRESSED AIR TUBING/PIPING. NTS A KEYPLAN - H-102B DN UP UP DN DN DN UP DN DN UP ---COURT YARD ---OPEN TO BELOW ---OPEN TO BELOW ---OPEN TO BELOW 1854182 15010022 72180 53182A6210059 2210076 18111868510058 13110057 15110029 114186A 26710066 42991842303181 2910023 28184A 28184B 3110028 124100102610074 2210061 710069 3051000717610035 3510037 13719011610012 2210042 UP DN DN UP UP UPDN UP DN UP UP UP UP DN UP UP DN DN UP UP UP UP DN DN DN DN BLDG. 2021ABLDG. 3028BLDG. 3028 BLDG. 2021 BLDG. 2021A BLDG. 2021 (E)8x8 DN (E)24x8 DN S 1 3 (E)FIN TUBE RADIATION (TYPICAL) (E)FAN COIL UNIT (TYPICAL) 2 1 S SS 279 598 278 210 277 787 276 780 20040 694 270A 7532 20015 34 20017 25 260A 119 260B 119 260 205 20049 307 261 189 262 153 263A 221 263 294 20006 253 263B 33 263C 33 265 340 OPEN TO BELOW --- 20050 1663 20051 121 20011 215 20079 41 FIREPLACE --- 272 208 271 257 20072 15 OPEN TO BELOW --- 20002 93 20049 258 20046 114 20066 34 20065 39 20045 167 20021 166 20020 163 227 --- 225 ---20049 --- 20067 --- 20066 --- 230A --- 230 --- 20048 --- 229 --- 20003 --- 228 --- 232 --- 234A --- 232A --- 234A --- 236 --- 235 --- 20068 --- 226 --- 226D --- 226C --- 226B --- 226A --- 224 250 222 229 220 230 218 230 216 230 214 230 212 216 210 227 208 262 206 289 208A 7 206A 8 204 276 204A 8 202A 5 202 307 20001 135 20040 235 221C 119 221 791 221B 30 223 44 20062 62 20061 54 222A 10 224A 10 217 122 213A 83 213 435 203 180 20042 997 220A 10 218A 9 216A 10 214A 10 210A 7 212A 7 (E)34x30 UP&DN (E)EF-5 4 222 2 2 2 2 (E)16x8(E)10x8(E)10x8 (E)24x8 (E)20x8 (E)24x12 (E)44x12 (E)66x12 (E)36x10(E)36x12 DN (E)8x20 DN (E)20x4(E)20x4(E)20x4(E)20x4(E)EF-115 (E)8x20 DN (E)12x20 UP(E)12x20 UP (E)12x20 UP & (E)8x20 DN (E)14x5(E)14x5 (E)20x7 (E)32x6(E)20x6(E)16x6(E)14x6(E)10x5(E)10x6 (E)14x6 (E)12x6 (E)10x611 (E)14x18 UP & (E)10x18 DN (E)14x5(E)8x5 (E)20x7 (E)20x7 (E)20x7(E)8x5 (E)8x5 (E)8x5 (E)7x5 (E)7x5 (E)7x5 (E)7x5 (E)12x5(E)16x5(E)16x5(E)12x5(E)12x5 (E)16x5 (E)16x5(E)12x5 (E)6x6 (E)24x6 (E)16x6 (E)6x6 (E)6x4(E)6x4 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN (E)6x4 (E)4x10 UP (E)16x36 UP&DN (E)16x6 (E)12x6(E)12x6 (E)6x6 (E)12x6 (E)10x3 (E)10x3 (E)6x4 (E)8x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)26x6 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)10x6 (E)10x6 AHU-4 AHU-4 (E)18x6 (E)72x10 UP (E)SUPPLY AIR DIFFUSER (TYPICAL) NORTH REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 PARTIAL SECOND FLOOR PLAN - DEMOLITION - HVAC H-103B 190306 RFG BMA 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor Hall1/8" = 1'-0" 1 PARTIAL SECOND FLOOR PLAN - DEMOLITION - HVAC DEMOLITION NOTES 1 DISCONNECT AND REMOVE EXISTING TEMPERATURE SENSOR, ASSOCIATED CONTROLS AND CONTROL ACCESSORIES. 2 DISCONNECT AND REMOVE EXISTING CONTROLS, CONTROL VALVE(S) AND CONTROL ACCESSORIES ASSOCIATED WITH EXISTING FAN COIL UNIT. 3 DISCONNECT AND REMOVE EXISTING CONTROLS, CONTROL VALVE AND CONTROL ACCESSORIES ASSOCIATED WITH EXISTING FIN TUBE RADIATION. 4 DISCONNECT AND REMOVE EXISTING CONTROLS AND CONTROL ACCESSORIES ASSOCIATED WITH EXISTING TRANSFER AIR FAN. 5 DISCONNECT AND REMOVE EXISTING CONTROLS AND CONTROL ACCESSORIES ASSOCIATED WITH EXISTING EXHAUST AIR FAN. GENERAL NOTES A. CONTRACTOR SHALL DISCONNECT AND REMOVE 120V CONNECTION FROM EXISTING CONTROL PANELS AND EXTEND & REWORK AS REQUIRED TO NEW CONTROL PANELS. WIRING SHALL BE (2)#12AWG & (1)*12EG IN 3/4" CONDUIT. B. DISCONNECT AND REMOVE ALL PNEUMATIC (COMPRESSED AIR) TUBING/PIPING AND ACCESSORIES BACK TO MAIN AND CAP AIR TIGHT. IF MATERIAL IS POLY, PROVIDE BRASS PLUG. TERMINATING BY BENDING END OF TUBING OR TERMINATING WITH A SHEETMETAL SCREW IS NOT ACCEPTABLE. THERE SHALL BE NO DEAD END BRANCH COMPRESSED AIR TUBING/PIPING. NTS A KEYPLAN - H-103B DN UP DN UP DN UP DN ---COURT YARD ---OPEN TO BELOW ---OPEN TO BELOW ---OPEN TO BELOW 1854182 15010022 72180 53182A6210059 2210076 18111868510058 13110057 15110029 114186A 26710066 42991842303181 2910023 28184A 28184B 3110028 124100102610074 2210061 710069 3051000717610035 3510037 137190116100122210042 UP DN DN UP UP UPDN UP DN UP UP UP UP DN UP UP DN DN UP UP UP UP DN DN DN DN BLDG. 2021A BLDG. 2021 BLDG. 2021A BLDG. 2021 17x10 UP&DN 2 S 2 (E)FAN COIL UNIT TYPICAL S 2222222 11 2 2 S S 1 S TO (E)AHU-3 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 1 1 2 2 (E)72x10 UP&DN 381 156 380 194 378A 811 378 6894 30041 255 30009 84 30079 41 376A 188 30048 288 375 140 375A 277 374 971 376 691 377 633 30063 89 30015 32 373 185 372 268 370 2302 30017 25 370A 162 370B 133 30040 220 30001 129 302 308 302A 9 304 290 304A 8 306A 8 306 310 308A 7 308 275 310 246 312 283 314 251 316 252 318 250 320 251 322 251 324 244 340A 140 340B 123 340C 226 310A 7 312A 7 314A 7 316A 6 318A 6 320A 6 322A 6 324A 6 30042 1015 315A 68 323 31 30062 6130061 54 30020 163 30021 166 321 131 319 119 317 106 315 715 309 112 307 167 303 184 302 102 OPEN TO BELOW --- 30002 87 30049 25930045 164 30066 34 30065 40 30046 132 349 101 30044 75 340E 213 30003 166 353 192 355 184 359 214 30049 448 350 203 352 126 30078 8 360 282 363 125 365 201 360A 43 30050 94 30006 47 340D 174 340 1538 30011 200 (E)36x12 UP (E)8x6 UP (E)EF-7 (E)28x6(E)22x6(E)18x6 (E)14x6 (E)18x6 (E)14x6 (E)12x6 (E)34x30 UP&DN AHU-4 (E)4x10 UP&DN (E)16x36 UP&DN AHU-4 (E)12x20 UP (E)12x20 DN (E)14x20 UP & (E)12x20 DN (E)14x22 UP & (E)14x18 DN (E)8x8 (E)6" (E)26x42 (E)40x34 UP (E)12x42 (E)20x42 (E)30x42 (E)34x42 (E)36x42 (E)36x42 (E)12x20 DN (E)36x12 UP (E)36x12 UP (E)36x12 DN(E)36x12 DN(E)36x12 DN(E)36x12 DN(E)36x12 DN(E)36x12 DN (E)14x20 UP (E)8x5 (E)24x5 (E)18x5(E)6x4 (E)10x4 (E)12x5(E)10x5(E)6x5 (E)10x5 (E)8x5 (E)14x5 (E)14x5 (E)8x5 (E)10x4 3 (E)14x5 (E)9x5 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)12x6 (E)10x6 (E)6x4 (E)6x4 (E)6x4(E)6x4 (E)6x6(E)8x6 (E)12x6 (E)6x4 (E)6x4 (E)6x4(E)6x4(E)6x4 (E)6x4 (E)6x4(E)6x4 (E)8x6 (E)6x4(E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)8x6 (E)12x6 (E)12x6(E)12x6 (E)6x4(E)14x6 (E)16x6 (E)6x4 (E)6x4 (E)6x4 (E)8x6 (E)26x5 (E)14x5 30072 15 NORTH REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 PARTIAL THIRD FLOOR PLAN - DEMOLITION - HVAC H-104B 190306 RFG BMA 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor Hall1/8" = 1'-0" 1 PARTIAL THIRD FLOOR PLAN - DEMOLITION - HVAC DEMOLITION NOTES 1 DISCONNECT AND REMOVE EXISTING TEMPERATURE SENSOR, ASSOCIATED CONTROLS AND CONTROL ACCESSORIES. 2 DISCONNECT AND REMOVE EXISTING CONTROLS, CONTROL VALVE(S) AND CONTROL ACCESSORIES ASSOCIATED WITH EXISTING FAN COIL UNIT. 3 DISCONNECT AND REMOVE EXISTING CONTROLS AND CONTROL ACCESSORIES ASSOCIATED WITH EXISTING TRANSFER AIR FAN. GENERAL NOTES A. CONTRACTOR SHALL DISCONNECT AND REMOVE 120V CONNECTION FROM EXISTING CONTROL PANELS AND EXTEND & REWORK AS REQUIRED TO NEW CONTROL PANELS. WIRING SHALL BE (2)#12AWG & (1)*12EG IN 3/4" CONDUIT. B. DISCONNECT AND REMOVE ALL PNEUMATIC (COMPRESSED AIR) TUBING/PIPING AND ACCESSORIES BACK TO MAIN AND CAP AIR TIGHT. IF MATERIAL IS POLY, PROVIDE BRASS PLUG. TERMINATING BY BENDING END OF TUBING OR TERMINATING WITH A SHEETMETAL SCREW IS NOT ACCEPTABLE. THERE SHALL BE NO DEAD END BRANCH COMPRESSED AIR TUBING/PIPING. NTS A KEYPLAN - H-104B UP DN DN DN ---COURT YARD ---OPEN TO BELOW ---OPEN TO BELOW ---OPEN TO BELOW 1854182 15010022 72180 53182A6210059 2210076 18111868510058 13110057 15110029 114186A 26710066 42991842303181 2910023 28184A 28184B 3110028 124100102610074 2210061 710069 3051000717610035 3510037 13719011610012 2210042 UP DN DN UP UP UP DN UP DN UP UP UP UP DN UP UP DN DN UP UP UP UP DN DN DN DN (E)60x16 (E)17x10 DN (E)52x16 (E)6'-0"x10'-0" OUTSIDE AIR INTAKE LOUVER (E)AHU-3 40001 130 40040 112 476 239 477 220 478 176 470 6,238 40015 17 40072 15 (E)46x16 (E)34x16 (E)26x16 (E)18x16 (E)17x10 (E)17x10 DN (E)17x10 DN (E)17x10 DN (E)17x10 DN (E)17x10 DN (E)17x10 DN (E)17x10 DN (E)24x20 DN (AHU-2) (E)24x20 DN (AHU-2) (E)20x18 DN (AHU-4) (E)24x20 DN (AHU-2) (E)24x20 DN (AHU-2) (E)20x18 DN (AHU-4) OPEN TO BELOW --- 3 H-300B (E)16x36 DN (E)16x3640045 186 40046 127 40066 36 40049 94 40044 15940003 69 474 87 40069 2,514 ROOF --- 40068 3,857 473 84 472 85 471 79 40076 10 OPEN TO BELOW --- 479 497 40009 23 (E)AHU-1 (E)AAD3 2 2 6 (E)OUTSIDE AIR LOUVER (E)20x80(E)RAF-1 S S SS TO (E)RHC-1 1 TO (E)RHC-3 1 (E)14x22 UP&DN(E)14x20 UP&DN (E)14x20 UP&DN (E)RAF-2 (E)48x30(E)RELIEF AIR LOUVER(E)36x24(E)34x30(E)34x30 (E)34x30 (E)36x24(E)24x36 (E)24x30(E)36x16(E)24x20(E)24x20(E)20x18(E)24x20(E)24x20(E)20x18(E)20x18 (E)10x20 UP (E)12x20 UP&DN TO (E)RHC-6 TO (E)RHC-8 (E)10x20 UP (E)72x10 UP&DN (E)34x30 UP&DN (E)EF-B5 (E)EF-A (E)EF-C 5 5 (E)EF-105 (E)EF-25 (E)EF-3 5 (E)EF-4 5 (E)EF-12 5 (E)8X6 UP&DN (E)60x16 (E)36x16 (E)OUTSIDE AIR INTAKE LOUVER (E)18x30 UP TO RETURN AIR PLENUM (E)18x30 UP TO RETURN AIR PLENUM (E)30x30x30 TRIANGULAR DUCT (E)36x30x60 TRIANGULAR DUCT (E)20x6(E)20x6 (E)17x46(E)12x46 (E)21x46 (E)21x46 (E)25x46 (E)25x46 (E)28x46 (E)31x46 (E)34x46 (E)46x34 UP (E)40x34 UP&DN (E)20x6(E)20x6 (E)14x6(E)14x6(E)14x6(E)14x6 (E)26x6 (E)14x6 (E)20x6 (E)14x6(E)14x6 (E)20x6(E)26x6 (E)20x6(E)14x6 (E)34x30(E)36x24 (E)AAD (E)AAD 3 (E)AHU-4 2 2 (E)AHU-22 2 (E)24x36 (E)34x30(E)24x20 (E)36x18 (E)36x16 (E)8x20 DN (E)8x20 (E)EF-1 5 3 (E)30x30(E)36x40(E)36x40(E)20x20(E)36x40 (E)24x20 (E)24x30 (E)24x30 (E)24x30 SUPPLY ABOVE & BELOW (E)24x30 RETURN ABOVE & BELOW 1 H-300B 2 H-300B 3(E)AAD3 (E)AAD 4 1 1 3 7 6 3 (E)AAD (E)AAD 3 3 (E)48x30(E)24x30(E)34x30(E)AAD3 4 H-300B 5 H-300B 8 (E)UH-4-5 (E)UH-4-48 S S TO (E)EF-4 1 (E)UH-4-3 (E)UH-4-2 8 8 8 (E)UH-4-1 S 1 S 1 S S 1 1 S NORTH REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 PARTIAL FOURTH FLOOR PLAN - DEMOLITION - HVAC H-105B 190306 RFG BMA 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor Hall1/8" = 1'-0" 1 PARTIAL FOURTH FLOOR PLAN - DEMOLITION - HVAC DEMOLITION NOTES 1 DISCONNECT AND REMOVE EXISTING TEMPERATURE SENSOR, ASSOCIATED CONTROLS AND CONTROL ACCESSORIES. 2 DISCONNECT AND REMOVE EXISTING CONTROLS AND CONTROL ACCESSORIES ASSOCIATED WITH EXISTING AIR HANDLING UNIT SYSTEM. 3 DISCONNECT AND REMOVE EXISTING DAMPER ACTUATORS ASSOCIATED WITH THE EXISTING AIR HANDLING UNIT SYSTEM. 4 DISCONNECT AND REMOVE EXISTING DAMPER ACTUATOR. 5 DISCONNECT AND REMOVE EXISTING CONTROLS AND CONTROL ACCESSORIES ASSOCIATED WITH EXISTING EXHAUST AIR FAN. 6 DISCONNECT AND REMOVE EXISTING HOT WATER REHEAT COIL CONTROL VALVE, ASSOCIATED CONTROLS AND CONTROL ACCESSORIES. 7 DISCONNECT AND REMOVE EXISTING GLYCOL PREHEAT COIL CONTROL VALVE, ASSOCIATED CONTROLS AND CONTROL ACCESSORIES. 8 DISCONNECT AND REMOVE EXISTING CONTROLS, CONTROL VALVE AND CONTROL ACCESSORIES ASSOCIATED WITH EXISTING UNIT HEATER. GENERAL NOTES A. CONTRACTOR SHALL DISCONNECT AND REMOVE 120V CONNECTION FROM EXISTING CONTROL PANELS AND EXTEND & REWORK AS REQUIRED TO NEW CONTROL PANELS. WIRING SHALL BE (2)#12AWG & (1)*12EG IN 3/4" CONDUIT. B. DISCONNECT AND REMOVE ALL PNEUMATIC (COMPRESSED AIR) TUBING/PIPING AND ACCESSORIES BACK TO MAIN AND CAP AIR TIGHT. IF MATERIAL IS POLY, PROVIDE BRASS PLUG. TERMINATING BY BENDING END OF TUBING OR TERMINATING WITH A SHEETMETAL SCREW IS NOT ACCEPTABLE. THERE SHALL BE NO DEAD END BRANCH COMPRESSED AIR TUBING/PIPING. NTS A KEYPLAN - H-105B DN DNUP UP ---COURT YARD ---OPEN TO BELOW ---OPEN TO BELOW ---OPEN TO BELOW 1854182 15010022 72180 53182A6210059 2210076 18111868510058 13110057 15110029 114186A 26710066 42991842303181 2910023 28184A 28184B 3110028 124100102610074 2210061 710069 3051000717610035 3510037 13719011610012 2210042 UP DN DN UP UP UPDN UP DN UP UP UP UP DN UP UP DN DN UP UP UP UP DN DN DN DN 514W 342 514 30 514E 341 514B 30 50010 111 50074 26 50036 79 ROOF --- ROOF --- ROOF --- 4P071 146 4P070 637 4P072 2800 40015 --- (E)40x34 DN (E)46x36 DN (E)34x30 DN (RAF-2)(E)34x30(E)72x10 DN (E)20x80 (E)RAF-3(E)40x36(E)46x36(E)48x18(E)20x80(E)20x80(E)30x30x30 TRIANGULAR DUCT (E)36x30x60 TRIANGULAR DUCT (E)34x30(E)34x30(E)20x10 DN (E)20x14 DN (E)RHC-8 (E)12x20 DN (E)10x20 DN (E)14x20 DN (E)10x20 DN (E)RHC-1 (E)34x30 ABOVE (E)RHC-2 1 1 (E)30x20 (E)24x20 (E)RHC-6 (E)RHC-3 (E)RHC-4 (E)30x20 1 1 1 1 1 1 (E)RHC-7 (E)22x14 DN (E)20x10 DN (E)RHC-5 (E)EF-1 COPIER EXHAUST FAN2 3 (E)UH-4-6 (E)UH-4-9 (E)UH-4-10 (E)UH-4-8 (E)UH-4-7 S S S S S 5 4 4 4 4 4 5 5 5 NORTH REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 PARTIAL ROOF FLOOR PLAN - DEMOLITION - HVAC H-106B 190306 RFG BMA 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor Hall1/8" = 1'-0" 1 PARTIAL FIFTH FLOOR ROOF PLAN - DEMOLITION - HVAC DEMOLITION NOTES 1 DISCONNECT AND REMOVE EXISTING REHEAT COIL CONTROL VALVE. 2 DISCONNECT AND REMOVE EXISTING CONTROLS AND CONTROL ACCESSORIES ASSOCIATED WITH EXISTING EXHAUST FAN. 3 DISCONNECT AND REMOVE EXISTING CONTROLS AND CONTROL ACCESSORIES ASSOCIATED WITH EXISTING AIR HANDLING UNIT SYSTEM. 4 DISCONNECT AND REMOVE EXISTING CONTROLS, CONTROL VALVE AND CONTROL ACCESSORIES ASSOCIATED WITH EXISTING UNIT HEATER. 5 DISCONNECT AND REMOVE EXISTING TEMPERATURE SENSOR, ASSOCIATED CONTROLS AND CONTROL ACCESSORIES. GENERAL NOTES A. CONTRACTOR SHALL DISCONNECT AND REMOVE 120V CONNECTION FROM EXISTING CONTROL PANELS AND EXTEND & REWORK AS REQUIRED TO NEW CONTROL PANELS. WIRING SHALL BE (2)#12AWG & (1)*12EG IN 3/4" CONDUIT. B. DISCONNECT AND REMOVE ALL PNEUMATIC (COMPRESSED AIR) TUBING/PIPING AND ACCESSORIES BACK TO MAIN AND CAP AIR TIGHT. IF MATERIAL IS POLY, PROVIDE BRASS PLUG. TERMINATING BY BENDING END OF TUBING OR TERMINATING WITH A SHEETMETAL SCREW IS NOT ACCEPTABLE. THERE SHALL BE NO DEAD END BRANCH COMPRESSED AIR TUBING/PIPING. NTS A KEYPLAN - H-106B UP UP ---COURT YARD ---OPEN TO BELOW ---OPEN TO BELOW ---OPEN TO BELOW 1854182 15010022 72180 53182A6210059 2210076 18111868510058 13110057 15110029 114186A 26710066 42991842303181 2910023 28184A 28184B 3110028 124100102610074 2210061 710069 3051000717610035 3510037 13719011610012 2210042 UP DN DN UP UP UPDN UP DN UP UP UP UP DN UP UP DN DN UP UP UP UP DN DN DN DN BLDG. 2021ABLDG. 3028BLDG. 3028 BLDG. 2021 BLDG. 2021A BLDG. 2021 B20 6,670 B20A 37 B20B 37 B0041 46 B0001 133 B0050 418 UTILITY TUNNEL --- B0006 70 B0067 26 B0025 119 B50 594 B0046 126 B0064 41 B0065 39 B0045 168 B0066 34 B0021 166 B0020 163 B0063 610 B0060 478 B0042 349 SS S TO (E)RHC-14 CH H C CHS S 1 1 (E)28x7 (E)24x7 (E)18x7 (E)12x7 (E)6x7 (E)6x4 (E)6x4 (E)28x7(E)20x7(E)20x7(E)16x7(E)16x7(E)10x7 (E)10x7 (E)26x7 (E)18x7(E)12x7 (E)RHC-15 2 RAF-2 AHU-2/RHC-15 S 1 TO (E)RHC-13 AHU-2/RHC-14 AHU-2/RHC-13 RAF-2 (E)10x6 (E)20x6 (E)12x6 (E)12x6 (E)8x5 (E)8x20 UP OS OS OS OS OSOS OS OS OS OS OS OS OS 3 3 3333 3 3 3 333 3 100 --- (E) TYP=4 50 --- (E) TYP=2 4 100 --- (E) TYP=4 4 4 275 --- (E) 4 275 --- (E) 275 --- (E) 4 4 1040 --- (E) 4 1035 --- (E) 190 --- (E) TO (E)RHC-154 4 190 --- (E) 190 --- (E) 190 --- (E) 4 44 190 --- (E) 190 --- (E) 44 NORTH EXISTING REHEAT COIL SCHEDULE TAG NO.GPM RHC-15 4.3 REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 PARTIAL BASEMENT FLOOR PLAN -NEW WORK -HVAC H-200B 190306 RFG BMA 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor Hall1/8" = 1'-0" 1 PARTIAL BASEMENT FLOOR PLAN - SOUTH - NEW WORK - HVAC DRAWING NOTES 1 PROVIDE NEW COMBINATION TEMPERATURE/HUMIDITY/CARBON DIOXIDE SENSOR. 2 PROVIDE NEW REHEAT COIL CONTROL VALVE. 3 PROVIDE WATTSTOPPER OCCUPANCY SENSOR TO CONTROL THE OPERATION OF THE ZONE. ALL OCCUPANCY SENSORS IN THE ZONE SHALL BE LINKED TOGETHER SUCH THAT IF ANY OF THE SENSORS INDICATE AN OCCUPIED CONDITION, THE ZONE WILL BE IN AN OCCUPIED MODE. 4 REBALANCE EXISTING DIFFUSER TO SCHEDULED AIRFLOW. GENERAL NOTES A. CONTRACTOR SHALL DISCONNECT AND REMOVE 120V CONNECTION FROM EXISTING CONTROL PANELS AND EXTEND & REWORK AS REQUIRED TO NEW CONTROL PANELS. WIRING SHALL BE (2)#12AWG & (1)*12EG IN 3/4" CONDUIT. B. DISCONNECT AND REMOVE ALL PNEUMATIC (COMPRESSED AIR) TUBING/PIPING AND ACCESSORIES BACK TO MAIN AND CAP AIR TIGHT. IF MATERIAL IS POLY, PROVIDE BRASS PLUG. TERMINATING BY BENDING END OF TUBING OR TERMINATING WITH A SHEETMETAL SCREW IS NOT ACCEPTABLE. THERE SHALL BE NO DEAD END BRANCH COMPRESSED AIR TUBING/PIPING. NTS A KEYPLAN - H-200B UP DN UP UP UP DN UP UP ---COURT YARD ---OPEN TO BELOW ---OPEN TO BELOW ---OPEN TO BELOW 1854182 15010022 72180 53182A6210059 2210076 18111868510058 13110057 15110029 114186A 26710066 42991842303181 2910023 28184A 28184B 3110028 124100102610074 2210061 710069 3051000717610035 3510037 13719011610012 2210042 UP DN DN UP UP UP DN UP DN UP UP UP UP DN UP UP DN DN UP UP UP UP DN DN DN DN BLDG. 2021ABLDG. 3028BLDG. 3028 BLDG. 2021 BLDG. 2021A BLDG. 2021 G70A 2779 G0015 34G71 54 B0006 --- G0054 103 OPEN TO BELOW --- G0069 27 G0046 119 G0066 34 G0065 39 G30 --- G0051 --- G0063 --- G0003 --- G0045 168 G0020 163G0021 166 G0062 64 G0061 55 G25A 14 G25 358 G20 7,841 G0041 29 G0001 145 G0016 24 G70 4080 G0058 29 G60A 121 G60 245 G62 264 G62A 13 G0056 152 G65 1510 G0006 70 G0014 73 G0055 99 G80 435 G70B 435 G70C 6 G0072 15 G0068 24 (E)20x7 (E)32x7(E)24x7 (E)20x7(E)12x7 (E)20x7(E)16x7(E)12x7 (E)12x7 (E)26x7(E)12x7 (E)20x7 (E)12x7 (E)12x7 (E)26x7 (E)20x7 (E)12x7 (E)16x5 (E)8x8 (E)20x8 (E)12x6 (E)6x6 (E)12x6(E)12x6 (E)12x6 (E)6x8 (E)12x5 (E)12x5(E)12x5 (E)12x5 (E)12x5 (E)12x5 (E)12x5 (E)7x5 (E)7x5 (E)7x5 (E)7x5 (E)RHC-14 (E)RHC-13 S S TO (E)RHC-11TO (E)RHC-10 S TO (E)RHC-9 S TO (E)RHC-12 1 1 1 TO ROOM B20 (E)SENSOR TO ROOM B20 (E)SENSOR 2 2 1 AHU-2/RHC-10 AHU-2/RHC-11 RAF-2 AHU-2/RHC-12 AHU-2/RHC-11 RAF-2AHU-2/RHC-9 90 --- (E) TYP=2 4 90 --- (E) TYP=4 4 90 --- (E) 4 90 --- (E) 4 90 --- (E) TYP=3 4 90 --- (E) TYP=4 4 90 --- (E) 4 280 --- (E) 4 280 --- (E) TYP=3 4 275 --- (E) 4 275 --- (E) 4 275 --- (E) 4 1445 --- (E) 4 1445 --- (E) 4 OS OS OSOS 3 33 OS OS 3 OS OS 3 OS OS 3 OS OS CH 3 3 3 3 3 3 CH HCCH 290 --- (E) 4 290 --- (E) 4 90 --- (E) 4 290 --- (E) 4 95 --- (E) 4 290 --- (E) 4 290 --- (E) 4 OS OS 3 OS OS 3 OS OS 3 OS OS 3 720 --- (E) 4 720 --- (E) 4 3 3 3 3 OS OS OS OS OS 3 3 3 3 3 G0057 26 G0051 117 LOADING DOCK --- (E)34x30 UPTO ROOM 170 SENSORS (RHC-2,4,5&7) NORTH EXISTING REHEAT COIL SCHEDULE TAG NO.GPM RHC-13 2.7 RHC-14 2.9 REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 PARTIAL GROUND FLOOR PLAN - NEW WORK -HVAC H-201B 190306 RFG BMA 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor Hall1/8" = 1'-0" 1 PARTIAL GROUND FLOOR PLAN - NEW WORK - HVAC DRAWING NOTES 1 PROVIDE NEW COMBINATION TEMPERATURE/HUMIDITY/CARBON DIOXIDE SENSOR. 2 PROVIDE NEW REHEAT COIL CONTROL VALVE. 3 PROVIDE WATTSTOPPER OCCUPANCY SENSOR TO CONTROL THE OPERATION OF THE ZONE. ALL OCCUPANCY SENSORS IN THE ZONE SHALL BE LINKED TOGETHER SUCH THAT IF ANY OF THE SENSORS INDICATE AN OCCUPIED CONDITION, THE ZONE WILL BE IN AN OCCUPIED MODE. 4 REBALANCE EXISTING DIFFUSER TO SCHEDULED AIRFLOW. GENERAL NOTES A. CONTRACTOR SHALL DISCONNECT AND REMOVE 120V CONNECTION FROM EXISTING CONTROL PANELS AND EXTEND & REWORK AS REQUIRED TO NEW CONTROL PANELS. WIRING SHALL BE (2)#12AWG & (1)*12EG IN 3/4" CONDUIT. B. DISCONNECT AND REMOVE ALL PNEUMATIC (COMPRESSED AIR) TUBING/PIPING AND ACCESSORIES BACK TO MAIN AND CAP AIR TIGHT. IF MATERIAL IS POLY, PROVIDE BRASS PLUG. TERMINATING BY BENDING END OF TUBING OR TERMINATING WITH A SHEETMETAL SCREW IS NOT ACCEPTABLE. THERE SHALL BE NO DEAD END BRANCH COMPRESSED AIR TUBING/PIPING. NTS A KEYPLAN - H-201B UP DN UP UP UP UP DN UP UP DN DN UP UP ---COURT YARD ---OPEN TO BELOW ---OPEN TO BELOW ---OPEN TO BELOW 1854182 15010022 72180 53182A6210059 2210076 18111868510058 13110057 15110029 114186A 26710066 42991842303181 2910023 28184A 28184B 3110028 124100102610074 2210061 710069 3051000717610035 3510037 13719011610012 2210042 UP DN DN UP UP UP DN UP DN UP UP UP UP DN UP UP DN DN UP UP UP UP DN DN DN DN BLDG. 2021ABLDG. 3028BLDG. 3028 BLDG. 2021 BLDG. 2021A BLDG. 2021 195 132 10067 113 197 98 194 2467 193 171 175 172 10055 19 10044 58 10051 219 10032 1237 10026 279 10064 44 10011 237 179 60 10027 18610063 26 10065 16 170A 96 10079 41 10016 25 10040 512 10001 138 104 283103 176 107 158 109 104115 692 105 101 106 292 108A 8 104A 8 10043 1942 PLANTER ---10002 81 117 98 119 110121 121 123 33 120 233 122 232 124 277 130 --- 130C --- 130B --- 130A --- 132 --- 134 --- 136 --- 138 --- 140 --- 142 --- 133 --- 135 --- 137 --- 139 --- 141 --- 135A ---10048 --- 10047 --- 128 --- 130D --- 126 --- 129 --- 131 --- 127 --- 10003 --- 10065 ---125 --- 10039 --- 10021 166 10020 163 10045 169 10046 119 10066 34 10065 39 10062 62 10061 54 115A 68 118 232 116 233 114 232 112 251 110 229 108 252 10042 981 10049 439 162 209 161 134 160 320 165 386 FIREPLACE --- 10041 43 167 26 10052 6 10053 6 10006 278 10050 1269 EXTERIOR ROOF TERRACE --- 10014 64 10017 24 170 8439 10072 15 10015 34 10009 84 10056 6 122A 10 124A 10 118A 10 120A 10 114A 10 116A 10 112A 7 110A 7 (E)36x12(E)20x10 (E)28x10 (E)36x10 (E)12x10 (E)18x6 (E)16x6(E)14x6 (E)6x4 (E)6x4 (E)6x4(E)8x6(E)10x6 (E)12x6 (E)12x6 (E)8x6 (E)8x4 (E)16x6(E)20x6 (E)12x5 (E)7x5 (E)12x5 (E)12x5 (E)16x5 (E)12x5 (E)7x5(E)7x5(E)7x5 (E)12x5 (E)7x5 (E)12x5(E)12x5 (E)12x6(E)12x6 (E)6x4(E)6x4(E)6x4 (E)8x6 (E)20x10 (E)14x10 (E)7x10 (E)26x10 (E)36x12(E)36x10 (E)16x6 (E)12x6 (E)10x6 (E)10x6 (E)6x4(E)6x4 (E)6x4(E)6x4 (E)8x6 (E)6x6 BLDG. 2021ABLDG. 3028BLDG. 3028 BLDG. 2021 BLDG. 2021A BLDG. 2021 S TO (E)RHC-2 2 TO ROOM G20 (E)SENSOR TO ROOM G20 (E)SENSOR TO ROOM G20 (E)SENSOR TO ROOM G20 (E)SENSOR 3 3 3 3 S S S S TO (E)RHC-4 2 2 2 2 TO (E)AHU-1 (E)FIN TUBE RADIATION (TYPICAL) S 2 4 77 7 3S (E)34x30 UP&DN (E)16x36 UP & (E)14x20 DN TO (E)RHC-17 8 7 7777 (E)17x10 UP (E)17x10 UP (E)17x10 UP (E)17x10 UP (E)17x10 UP (E)36x12 UP 5 63 (E)RHC-10 (E)RHC-9 (E)RHC-12 (E)RHC-11 (E)AHU-5 (E)EF-6 (E)RHC-16 (E)RHC-17 H 1 AHU-4 AHU-4 C H CHCH CH CH CV-1-01 CV-1-02 CV-1-03 CV-1-04 CV-1-05 CV-1-06 CV-1-08 CV-1-07 OS OSOS 9 99 OS OS 9 9 OS OS 9 9 OS 9 OS OS 9 9 OS 9 OS9 OS9 OS 9 TO (E)RHC-7 TO (E)RHC-5 11 11 11 11 11 85 - (E) TYP=2 85 - (E) TYP=3 775 --- (E) 780 --- (E) 85 - (E) TYP=2 85 - (E) TYP=2 11 85 - (E) TYP=3 90 - (E) TYP=-4 11 11 85 - (E) 90 - (E) 11 11 OS OS OS 10 10 10 (E)17x10 UP (E)17x10 UP (E)17x10 UP (E)24x8 & (E)8x8 UP H TO ROOM 194 SENSOR TO ROOM 276,277&279 SENSORS 12 C 13 13 14 EXISTING PERIMETER CONTROL VALVE SCHEDULE TAG NO.GPM CV-1-01 0.8 CV-1-02 0.9 CV-1-03 0.9 CV-1-04 0.9 CV-1-05 0.9 CV-1-06 0.9 CV-1-07 0.9 CV-1-08 0.9 NORTH EXISTING AHU CONTROL VALVE SCHEDULE TAG NO.SERVICE GPM AHU-5-PHC GLYCOL PREHEAT COIL 17.4 AHU-5-CC CHILLED WATER COOLING COIL 29.0 EXISTING REHEAT COIL SCHEDULE TAG NO.GPM RHC-9 3.5 RHC-10 1.9 RHC-11 2.8 RHC-12 2.3 RHC-16 2.5 RHC-17 7.1 REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 PARTIAL FIRST FLOOR PLAN - NEW WORK -HVAC H-202B 190306 RFG BMA 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor Hall1/8" = 1'-0" 1 PARTIAL FIRST FLOOR PLAN - NEW WORK - HVAC NTS A KEYPLAN - H-202B DRAWING NOTES GENERAL NOTES A. CONTRACTOR SHALL DISCONNECT AND REMOVE 120V CONNECTION FROM EXISTING CONTROL PANELS AND EXTEND & REWORK AS REQUIRED TO NEW CONTROL PANELS. WIRING SHALL BE (2)#12AWG & (1)*12EG IN 3/4" CONDUIT. B. DISCONNECT AND REMOVE ALL PNEUMATIC (COMPRESSED AIR) TUBING/PIPING AND ACCESSORIES BACK TO MAIN AND CAP AIR TIGHT. IF MATERIAL IS POLY, PROVIDE BRASS PLUG. TERMINATING BY BENDING END OF TUBING OR TERMINATING WITH A SHEETMETAL SCREW IS NOT ACCEPTABLE. THERE SHALL BE NO DEAD END BRANCH COMPRESSED AIR TUBING/PIPING. 1 PROVIDE NEW COMBINATION TEMPERATURE/HUMIDITY SENSOR. 2 PROVIDE NEW COMBINATION TEMPERATURE/HUMIDITY/CARBON DIOXIDE SENSOR. 3 PROVIDE NEW REHEAT COIL CONTROL VALVE. 4 EXISTING AIR HANDLING UNIT SHALL BE RECOMMISSIONED AND RECALIBRATED. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 5 PROVIDE NEW CHILLED WATER COIL CONTROL VALVE. 6 PROVIDE NEW GYLCOL PREHEAT COIL CONTROL VALVE. 7 PROVIDE NEW CONTROLS AND CONTROL VALVE FOR EXISTING FIN TUBE RADIATION. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 8 PROVIDE NEW CONTROLS AND CONTROL ACCESSORIES FOR EXISTING TRANSFER AIR FAN. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 9 PROVIDE WATTSTOPPER OCCUPANCY SENSOR TO CONTROL THE OPERATION OF THE ZONE. ALL OCCUPANCY SENSORS IN THE ZONE SHALL BE LINKED TOGETHER SUCH THAT IF ANY OF THE SENSORS INDICATE AN OCCUPIED CONDITION, THE ZONE WILL BE IN AN OCCUPIED MODE. 10 PROVIDE HUBBELL ATD1600WRP WALL MOUNTED OCCUPANCY SENSOR OR EQUAL TO CONTROL THE OPERATION OF THE ZONE. MOUNT AT MANUFACTURERS RECOMMENDED HEIGHT. ALL OCCUPANCY SENSORS IN THE ZONE SHALL BE LINKED TOGETHER SUCH THAT IF ANY OF THE SENSORS INDICATE AN OCCUPIED CONDITION, THE ZONE WILL BE IN AN OCCUPIED MODE. 11 REBALANCE EXISTING DIFFUSER TO SCHEDULED AIRFLOW. 12 PROVIDE NEW ELECTRONIC DAMPER ACTUATORS ASSOCIATED WITH EXISTING AIR HANDLING UNIT SYSTEM. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 13 PROVIDE REHEAT COIL TEMPERATURE CONTROL PANEL IN THE FOLLOWING LOCATION. 14 PROVIDE AHU-5 TEMPERATURE CONTROL PANEL IN THE FOLLOWING LOCATION. DN UP UP DN DN DN UP DN DN UP ---COURT YARD ---OPEN TO BELOW ---OPEN TO BELOW ---OPEN TO BELOW 1854182 15010022 72180 53182A6210059 2210076 18111868510058 13110057 15110029 114186A 26710066 42991842303181 2910023 28184A 28184B 3110028 124100102610074 2210061 710069 3051000717610035 3510037 13719011610012 2210042 UP DN DN UP UP UPDN UP DN UP UP UP UP DN UP UP DN DN UP UP UP UP DN DN DN DN BLDG. 2021ABLDG. 3028BLDG. 3028 BLDG. 2021 BLDG. 2021A BLDG. 2021 (E)16x8(E)10x8(E)10x8 (E)24x8 (E)20x8 (E)24x12 (E)44x12 (E)66x12 (E)36x10(E)20x4(E)20x4(E)20x4(E)20x4(E)20x7 (E)32x6(E)20x6(E)16x6(E)14x6(E)10x5(E)10x6 (E)14x6 (E)12x6 (E)10x6(E)14x5(E)8x5 (E)20x7 (E)20x7 (E)20x7(E)8x5 (E)8x5 (E)8x5 (E)7x5 (E)7x5 (E)12x5(E)12x5(E)12x5 (E)16x5 (E)12x5 (E)6x6 (E)24x6 (E)16x6 (E)6x6 (E)6x4(E)6x4 (E)6x4 (E)16x6 (E)12x6(E)12x6 (E)6x6 (E)12x6 (E)10x3 (E)10x3 (E)6x4 (E)8x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)26x6 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)10x6 (E)10x6 (E)18x6 279 598 278 210 277 787 276 780 20040 694 270A 7532 20015 34 20017 25 260A 119 260B 119260 205 20049 307 261 189 262 153 263A 221 263 294 20006 253 263B 33 263C 33 265 340 OPEN TO BELOW --- 20050 1663 20051 121 20011 215 20079 41 FIREPLACE --- 272 208 20072 15 OPEN TO BELOW --- 20002 93 20049 258 20046 114 20066 34 20065 39 20045 167 20021 166 20020 163 227 --- 225 ---20049 --- 20067 --- 20066 --- 230A --- 230 --- 20048 --- 229 --- 20003 --- 228 --- 232 --- 234A --- 232A --- 234A --- 236 --- 235 --- 20068 --- 226 --- 226D --- 226C --- 226B --- 226A --- 224 250 222 229 220 230 218 230 216 230 214 230 212 216 210 227 208 262 206 289 208A 7 206A 8 204 276 204A 8 202A 5 202 307 20001 135 20040 235 221C 119 221 791 221B 30 223 44 20062 62 20061 54 222A 10 224A 10 217 122 213A 83 213 435 203 180 20042 997 220A 10 218A 9 216A 10 214A 10 210A 7 212A 7 (E)8x8 DN (E)24x8 DN S 1 4 (E)FIN TUBE RADIATION (TYPICAL) (E)FAN COIL UNIT (TYPICAL) 3 1 S SS (E)34x30 UP&DN 5 333 3 3 3 3 (E)16x8(E)10x8 (E)36x12 DN (E)8x20 DN 6 (E)8x20 DN (E)12x20 UP(E)12x20 UP (E)12x20 UP & (E)8x20 DN 11 (E)14x18 UP & (E)10x18 DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN (E)4x10 UP (E)16x36 UP&DN AHU-4 AHU-4 (E)EF-5 (E)EF-11 980 --- (E) 985 --- (E) 22 HH H H CV-2-01FCU-2-02FCU-2-01 FCU-2-03 FCU-2-04 FCU-2-05 FCU-2-06 FCU-2-07 FCU-2-08 OS OS OSOS 77 OSOS 77 OS 7 OS7 OS OS 7 OS 7 OS OS OS OS 7 7 77 777 90 --- (E) TYP=3 2 115 --- (E) 2 110 --- (E) 2 110 --- (E) 2110 --- (E) TYP=4 2 110 --- (E) 2 2 2 90 --- (E) TYP=6 271 257 (E)72x10 UP TO ROOM 170 SENSORS (RHC-2,4,5&7) 90 --- (E) TYP=3 TO (E)RHC-16 TO (E)RHC-16 TO (E)RHC-16 (E)SUPPLY AIR DIFFUSER(TYPICAL) NORTHEXISTING FAN COIL UNIT SCHEDULE TAG NO.UNIT TYPE CFM CHILLED WATER HOT WATER AREA(S) SERVEDFLOW (GPM) FLOW (GPM) FCU-2-01 FOUR PIPE FAN COIL UNIT 730 2.1 1.0 ROOM 279 FCU-2-02 FOUR PIPE FAN COIL UNIT 730 2.1 1.0 ROOM 279 FCU-2-03 FOUR PIPE FAN COIL UNIT 730 2.1 1.0 ROOM 277 FCU-2-04 FOUR PIPE FAN COIL UNIT 730 2.1 1.0 ROOM 277 FCU-2-05 FOUR PIPE FAN COIL UNIT 730 2.1 1.0 ROOM 277 FCU-2-06 FOUR PIPE FAN COIL UNIT 730 2.1 1.0 ROOM 276 FCU-2-07 FOUR PIPE FAN COIL UNIT 730 2.1 1.0 ROOM 276 FCU-2-08 FOUR PIPE FAN COIL UNIT 730 2.1 1.0 ROOM 276 EXISTING PERIMETER CONTROL VALVE SCHEDULE TAG NO.GPM CV-2-01 0.85 REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 PARTIAL SECOND FLOOR PLAN - NEW WORK -HVAC H-203B 190306 RFG BMA 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor Hall1/8" = 1'-0" 1 PARTIAL SECOND FLOOR PLAN - NEW WORK - HVAC NTS A KEYPLAN - H-203B DRAWING NOTES 1 PROVIDE NEW COMBINATION TEMPERATURE/HUMIDITY SENSOR. 2 REBALANCE EXISTING DIFFUSER TO SCHEDULED AIRFLOW. 3 PROVIDE NEW CONTROLS, CONTROL VALVE AND CONTROL ACCESSORIES FOR EXISTING FAN COIL UNIT. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 4 PROVIDE NEW CONTROLS, CONTROL VALVE AND CONTROL ACCESSORIES FOR EXISTING FIN TUBE RADIATION. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 5 PROVIDE NEW CONTROLS AND CONTROL ACCESSORIES FOR EXISTING TRANSFER AIR FAN. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 6 PROVIDE NEW CONTROLS AND CONTROL ACCESSORIES FOR EXISTING EXHAUST AIR FAN. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 7 PROVIDE WATTSTOPPER OCCUPANCY SENSOR TO CONTROL THE OPERATION OF THE ZONE. ALL OCCUPANCY SENSORS IN THE ZONE SHALL BE LINKED TOGETHER SUCH THAT IF ANY OF THE SENSORS INDICATE AN OCCUPIED CONDITION, THE ZONE WILL BE IN AN OCCUPIED MODE. GENERAL NOTES A. CONTRACTOR SHALL DISCONNECT AND REMOVE 120V CONNECTION FROM EXISTING CONTROL PANELS AND EXTEND & REWORK AS REQUIRED TO NEW CONTROL PANELS. WIRING SHALL BE (2)#12AWG & (1)*12EG IN 3/4" CONDUIT. B. DISCONNECT AND REMOVE ALL PNEUMATIC (COMPRESSED AIR) TUBING/PIPING AND ACCESSORIES BACK TO MAIN AND CAP AIR TIGHT. IF MATERIAL IS POLY, PROVIDE BRASS PLUG. TERMINATING BY BENDING END OF TUBING OR TERMINATING WITH A SHEETMETAL SCREW IS NOT ACCEPTABLE. THERE SHALL BE NO DEAD END BRANCH COMPRESSED AIR TUBING/PIPING. DN UP DN UP DN UP DN ---COURT YARD ---OPEN TO BELOW ---OPEN TO BELOW ---OPEN TO BELOW 1854182 15010022 72180 53182A6210059 2210076 18111868510058 13110057 15110029 114186A 26710066 42991842303181 2910023 28184A 28184B 3110028 124100102610074 2210061 710069 3051000717610035 3510037 137190116100122210042 UP DN DN UP UP UPDN UP DN UP UP UP UP DN UP UP DN DN UP UP UP UP DN DN DN DN BLDG. 2021A BLDG. 2021 BLDG. 2021A BLDG. 2021 2 S 2 (E)FAN COIL UNIT TYPICAL S 2222222 11 2 2 S S 1 S TO (E)AHU-3 HC 1 1 2 2 H H H H FCU-3-01 FCU-3-02 FCU-3-03 FCU-3-04 FCU-3-05 FCU-3-06 FCU-3-07 FCU-3-08 FCU-3-09 FCU-3-10 FCU-3-11 FCU-3-12 FCU-3-13 (E)28x6(E)22x6(E)18x6 (E)14x6 (E)18x6 (E)14x6 (E)12x6 (E)6" (E)8x5 (E)24x5 (E)18x5(E)6x4 (E)10x4 (E)12x5(E)10x5(E)6x5 (E)10x5 (E)14x5 (E)8x5 (E)10x4 (E)14x5 (E)9x5 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)12x6 (E)10x6 (E)6x4 (E)6x4 (E)6x4(E)6x4 (E)6x6(E)8x6 (E)12x6 (E)6x4 (E)6x4 (E)6x4(E)6x4(E)6x4 (E)6x4 (E)6x4(E)6x4 (E)8x6 (E)6x4(E)6x4 (E)6x4 (E)6x4 (E)6x4 (E)8x6 (E)12x6 (E)12x6(E)12x6 (E)6x4(E)14x6 (E)16x6 (E)6x4 (E)6x4 (E)6x4 (E)8x6 BLDG. 2021A BLDG. 2021 BLDG. 2021A BLDG. 2021 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN 17x10 UP&DN (E)72x10 UP&DN 381 156 380 194 378A 811 378 6894 30041 255 30009 84 30079 41 30048 288 375A 277 376 691 377 633 30063 89 30015 32 30040 220 30001 129 302 308 302A 9 304 290 304A 8 306A 8 306 310 308A 7 308 275 310 246 312 283 314 251 316 252 318 250 320 251 322 251 324 244 340A 140 340B 123 340C 226 310A 7 312A 7 314A 7 316A 6 318A 6 320A 6 322A 6 324A 6 30042 1015 315A 68 323 31 30062 6130061 54 30020 163 30021 166 321 131 319 119 317 106 315 715 309 112 307 167 303 184 302 102 OPEN TO BELOW --- 30002 87 30049 25930045 164 30066 34 30065 40 30046 132 349 101 30044 75 340E 213 30003 166 353 192 355 184 359 214 30049 448 352 126 30078 8 360 282 363 125 365 201 360A 43 30050 94 30006 47 340D 174 340 1538 30011 200 (E)36x12 UP (E)34x30 UP&DN AHU-4 (E)4x10 UP&DN (E)16x36 UP&DN AHU-4 (E)12x20 UP (E)12x20 DN (E)14x20 UP & (E)12x20 DN (E)14x22 UP & (E)14x18 DN (E)26x42 (E)40x34 UP (E)12x42 (E)20x42 (E)30x42 (E)34x42 (E)36x42 (E)36x42 (E)12x20 DN (E)36x12 UP (E)36x12 DN(E)36x12 DN(E)36x12 DN(E)36x12 DN(E)36x12 DN(E)36x12 DN (E)14x20 UP 3(E)EF-7 105 --- (E) TYP=2 5 381 156 380 194 381 156 380 194 375 140 30072 15 370A 162 370B 133 1370 --- (E) (E)26x5 (E)14x5 100 --- (E) 5 50 --- (E) 5 60 --- (E) TYP=3 5 110 --- (E) TYP=2 100 --- (E) 5 OS OS OS OS OS 4 OS 4 OS 4 OS 4 TO ROOM 170 SENSORS (RHC-2,4,5&7) 70 --- (E) 5 OS OS 44 OS OS OS OS OS 4 OS 4 OS (E)14x5 OS 4 OS 4 OS5 OS 4 4 4 4 4 110 --- (E) 4 4 4 4 376A 188 44 25 --- (E) 25 --- (E) 85 --- (E) 555 95 --- (E) 5 5 5 (E)8x6 UP 100 --- (E) 5 C C CC (E)BOOKSHELF (TYPICAL) TO(E)AHU-3 TO(E)AHU-3 TO(E)AHU-3 TO(E)AHU-3 EXISTING FAN COIL UNIT SCHEDULE TAG NO.UNIT TYPE CFM CHILLED WATER HOT WATER AREA(S) SERVEDFLOW (GPM) FLOW (GPM) FCU-3-01 FOUR PIPE FAN COIL UNIT 1130 2.9 3.5 ROOM 378 FCU-3-02 FOUR PIPE FAN COIL UNIT 1130 2.9 3.5 ROOM 378 FCU-3-03 FOUR PIPE FAN COIL UNIT 475 1.3 2.0 ROOM 378 FCU-3-04 FOUR PIPE FAN COIL UNIT 475 1.3 2.0 ROOM 378 FCU-3-05 FOUR PIPE FAN COIL UNIT 475 1.3 2.0 ROOM 378 FCU-3-06 FOUR PIPE FAN COIL UNIT 475 1.3 2.0 ROOM 378 FCU-3-07 FOUR PIPE FAN COIL UNIT 475 1.3 2.0 ROOM 378 FCU-3-08 FOUR PIPE FAN COIL UNIT 475 1.3 2.0 ROOM 378 FCU-3-09 FOUR PIPE FAN COIL UNIT 475 1.3 2.0 ROOM 378 FCU-3-10 FOUR PIPE FAN COIL UNIT 475 1.3 2.0 ROOM 378 FCU-3-11 FOUR PIPE FAN COIL UNIT 475 1.3 2.0 ROOM 378 FCU-3-12 FOUR PIPE FAN COIL UNIT 1130 2.9 3.5 ROOM 378 FCU-3-13 FOUR PIPE FAN COIL UNIT 1130 2.9 3.5 ROOM 378 NORTH REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 PARTIAL THIRD FLOOR PLAN - NEW WORK -HVAC H-204B 190306 RFG BMA 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor Hall1/8" = 1'-0" 1 PARTIAL THIRD FLOOR PLAN - NEW WORK - HVAC DRAWING NOTES 1 PROVIDE NEW COMBINATION TEMPERATURE/HUMIDITY/CARBON DIOXIDE SENSOR. 2 PROVIDE NEW CONTROLS, CONTROL VALVE AND CONTROL ACCESSORIES FOR EXISTING FAN COIL UNIT. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 3 PROVIDE NEW CONTROLS AND CONTROL ACCESSORIES FOR EXISTING TRANSFER AIR FAN. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 4 PROVIDE WATTSTOPPER OCCUPANCY SENSOR TO CONTROL THE OPERATION OF THE ZONE. ALL OCCUPANCY SENSORS IN THE ZONE SHALL BE LINKED TOGETHER SUCH THAT IF ANY OF THE SENSORS INDICATE AN OCCUPIED CONDITION, THE ZONE WILL BE IN AN OCCUPIED MODE. 5 REBALANCE EXISTING DIFFUSER TO SCHEDULED AIRFLOW. GENERAL NOTES A. CONTRACTOR SHALL DISCONNECT AND REMOVE 120V CONNECTION FROM EXISTING CONTROL PANELS AND EXTEND & REWORK AS REQUIRED TO NEW CONTROL PANELS. WIRING SHALL BE (2)#12AWG & (1)*12EG IN 3/4" CONDUIT. B. DISCONNECT AND REMOVE ALL PNEUMATIC (COMPRESSED AIR) TUBING/PIPING AND ACCESSORIES BACK TO MAIN AND CAP AIR TIGHT. IF MATERIAL IS POLY, PROVIDE BRASS PLUG. TERMINATING BY BENDING END OF TUBING OR TERMINATING WITH A SHEETMETAL SCREW IS NOT ACCEPTABLE. THERE SHALL BE NO DEAD END BRANCH COMPRESSED AIR TUBING/PIPING. NTS A KEYPLAN - H-204B UP DN DN DN ---COURT YARD ---OPEN TO BELOW ---OPEN TO BELOW ---OPEN TO BELOW 1854182 15010022 72180 53182A6210059 2210076 18111868510058 13110057 15110029 114186A 26710066 42991842303181 2910023 28184A 28184B 3110028 124100102610074 2210061 710069 3051000717610035 3510037 13719011610012 2210042 UP DN DN UP UP UPDN UP DN UP UP UP UP DN UP UP DN DN UP UP UP UP DN DN DN DN 6 H-300B 3 H-300B 1 H-300B 2 H-300B 40001 130 40040 112 476 239 477 220 478 176 40015 17 OPEN TO BELOW --- 40045 186 40046 127 40066 36 40049 94 40044 15940003 69 474 87 40069 2,514 ROOF --- 40068 3,857 473 84 472 85 471 79 40076 10 OPEN TO BELOW --- 479 497 40009 23 (E)AAD S S SS (E)60x16(E)52x16 (E)46x16 (E)34x16 (E)26x16 (E)18x16 (E)17x10 (E)16x36(E)20x80(E)48x30(E)36x24(E)34x30(E)34x30 (E)34x30 (E)36x24(E)24x36 (E)24x30(E)36x16(E)24x20(E)24x20(E)20x18(E)24x20(E)24x20(E)20x18(E)20x18 (E)60x16 (E)36x16 (E)17x46(E)12x46 (E)21x46 (E)21x46 (E)25x46 (E)25x46 (E)28x46 (E)31x46 (E)34x46 (E)14x6(E)14x6(E)14x6(E)14x6 (E)14x6 (E)20x6 (E)14x6(E)14x6(E)20x6(E)14x6 (E)34x30(E)36x24 (E)24x36 (E)34x30(E)24x20 (E)36x18 (E)36x16 (E)8x20 (E)30x30(E)36x40(E)36x40(E)20x20(E)36x40 (E)24x20 (E)24x30 (E)24x30 (E)17x10 DN (E)6'-0"x10'-0" OUTSIDE AIR INTAKE LOUVER (E)17x10 DN (E)17x10 DN (E)17x10 DN (E)17x10 DN (E)17x10 DN (E)17x10 DN (E)17x10 DN (E)24x20 DN (AHU-2) (E)24x20 DN (AHU-2) (E)20x18 DN (AHU-4) (E)24x20 DN (AHU-2) (E)24x20 DN (AHU-2) (E)20x18 DN (AHU-4) (E)16x36 DN (E)OUTSIDE AIR LOUVER TO (E)RHC-1 TO (E)RHC-3 (E)14x22 UP&DN(E)14x20 UP&DN (E)RELIEF AIR LOUVER (E)10x20 UP TO (E)RHC-6 TO (E)RHC-8 (E)10x20 UP (E)72x10 UP&DN (E)34x30 UP&DN (E)8X6 UP&DN (E)18x30 UP TO RETURN AIR PLENUM (E)18x30 UP TO RETURN AIR PLENUM (E)30x30x30 TRIANGULAR DUCT (E)36x30x60 TRIANGULAR DUCT (E)46x34 UP (E)40x34 UP&DN (E)AAD (E)AAD (E)8x20 DN (E)24x30 RETURN ABOVE & BELOW (E)AAD (E)AAD 3 2 6 1 1 5 5 5 5 5 5 5 3 2 2 2 5 3 3 1 1 3 7 6 3 3 3 (E)AHU-1 (E)RAF-1 (E)RAF-2 (E)EF-B (E)EF-A (E)EF-C (E)EF-10 (E)EF-2 (E)EF-3 (E)EF-4 (E)EF-12 (E)AHU-2 (E)EF-1 (E)AAD 4 (E)AAD 5 CH H C CHCH (E)48x30(E)34x30(E)24x3010x10 BELOW 14x14 BELOW (E)AAD3 7 H-300B 12x12 BELOW 470 6,238 40072 15 OS OSOS 8 8 8 OS 8 OS 8 OS 8 OS 8 OS 8 OS OS 8 8 (E)10x20 UP 2115 --- (E) 2110 --- (E) 9 9 165 --- (E) TYP=2 9 (E)10x6 165 --- (E) 9 165 --- (E) 9 9 165 --- (E) TYP=4 165 --- (E) TYP=2 9 165 --- (E) TYP=3 9 160 --- (E) TYP=3 99 9 160 --- (E) TYP=6160 --- (E) TYP=3 160 --- (E) 9 (E)AHU-3 2 3 (E)EF-4 10 (E)UH-4-5 S TO (E)EF-4 11 S 11 (E)OUTSIDE AIR INTAKE LOUVER (E)AHU-4 2 (E)UH-4-410 (E)24x30 SUPPLY ABOVE & BELOW (E)UH-4-3 (E)UH-4-2 10 10 10 (E)UH-4-1 S 11 S 11 11 S 1213 13 13 (E)12x20 UP&DN(E)14x20 UP&DN (E)10x20 UP NORTH EXISTING AHU CONTROL VALVE SCHEDULE TAG NO.SERVICE GPM AHU-1-RHC HOT WATER REHEAT COIL 18.2 AHU-2-CC CHILLED WATER COOLING COIL 74.0 AHU-4-PHC GLYCOL PREHEAT COIL 18.9 AHU-4-RHC HOT WATER REHEAT COIL 6.4 EXISTING UNIT HEATER SCHEDULE TAG NO.GPM UH-4-1 3.8 UH-4-2 3.8 UH-4-3 3.8 UH-4-4 3.8 UH-4-5 3.8 REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 PARTIAL FOURTH FLOOR PLAN - NEW WORK -HVAC H-205B 190306 RFG BMA 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor Hall1/8" = 1'-0" 1 PARTIAL FOURTH FLOOR PLAN - NEW WORK - HVAC NTS A KEYPLAN - H-205B DRAWING NOTES 1 PROVIDE NEW COMBINATION TEMPERATURE/HUMIDITY/CARBON DIOXIDE SENSOR. 2 EXISTING AIR HANDLING UNIT SYSTEM SHALL BE RECOMMISSIONED AND ALL EXISTING CONTROLS SHALL BE REPLACED. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 3 PROVIDE NEW ELECTRONIC DAMPER ACTUATORS ASSOCIATED WITH EXISTING AIR HANDLING UNIT SYSTEM. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 4 PROVIDE NEW ELECTRONIC DAMPER ACTUATOR. 5 PROVIDE NEW CONTROLS AND CONTROL ACCESSORIES FOR EXISTING EXHAUST AIR FAN. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 6 PROVIDE NEW HOT WATER REHEAT COIL CONTROL VALVE. 7 PROVIDE NEW GLYCOL PREHEAT COIL CONTROL VALVE. 8 PROVIDE WATTSTOPPER OCCUPANCY SENSOR TO CONTROL THE OPERATION OF THE ZONE. ALL OCCUPANCY SENSORS IN THE ZONE SHALL BE LINKED TOGETHER SUCH THAT IF ANY OF THE SENSORS INDICATE AN OCCUPIED CONDITION, THE ZONE WILL BE IN AN OCCUPIED MODE. 9 REBALANCE EXISTING DIFFUSER TO SCHEDULED AIRFLOW. 10 PROVIDE NEW CONTROLS, CONTROL VALVE AND CONTROL ACCESSORIES FOR EXISTING UNIT HEATER. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 11 PROVIDE NEW TEMPERATURE SENSOR. 12 EXISTING AIR HANDLING UNIT COILS SHALL BE THOROUGHLY CLEANED. 13 PROVIDE TEMPERATURE CONTROL PANEL IN THE FOLLOWING LOCATION. GENERAL NOTES A. CONTRACTOR SHALL DISCONNECT AND REMOVE 120V CONNECTION FROM EXISTING CONTROL PANELS AND EXTEND & REWORK AS REQUIRED TO NEW CONTROL PANELS. WIRING SHALL BE (2)#12AWG & (1)*12EG IN 3/4" CONDUIT. B. DISCONNECT AND REMOVE ALL PNEUMATIC (COMPRESSED AIR) TUBING/PIPING AND ACCESSORIES BACK TO MAIN AND CAP AIR TIGHT. IF MATERIAL IS POLY, PROVIDE BRASS PLUG. TERMINATING BY BENDING END OF TUBING OR TERMINATING WITH A SHEETMETAL SCREW IS NOT ACCEPTABLE. THERE SHALL BE NO DEAD END BRANCH COMPRESSED AIR TUBING/PIPING. DN DNUP UP ---COURT YARD ---OPEN TO BELOW ---OPEN TO BELOW ---OPEN TO BELOW 1854182 15010022 72180 53182A6210059 2210076 18111868510058 13110057 15110029 114186A 26710066 42991842303181 2910023 28184A 28184B 3110028 124100102610074 2210061 710069 3051000717610035 3510037 13719011610012 2210042 UP DN DN UP UP UPDN UP DN UP UP UP UP DN UP UP DN DN UP UP UP UP DN DN DN DN (E)40x36 DN (E)46x36 DN (E)34x30 DN (RAF-2) (E)72x10 DN (E)20x80 (E)30x30x30 TRIANGULAR DUCT (E)36x30x60 TRIANGULAR DUCT (E)20x10 DN (E)20x14 DN (E)12x20 DN (E)10x20 DN (E)14x20 DN (E)10x20 DN (E)34x30 ABOVE 1 1 1 1 1 1 1 1 514W 342 514 30 514E 341 514B 30 50010 111 50074 26 50036 79 ROOF --- ROOF --- ROOF --- 4P071 146 4P070 637 4P072 2800 40015 ---(E)34x30(E)RAF-3(E)40x36(E)46x36(E)48x18(E)20x80(E)20x80(E)34x30(E)34x30(E)RHC-8 (E)RHC-1 (E)RHC-2 (E)30x20 (E)24x20 (E)RHC-5 (E)RHC-6 (E)RHC-3 (E)RHC-4 (E)30x20 (E)RHC-7 (E)22x14 DN (E)20x10 DN 3 (E)EF-1 COPIER EXHAUST FAN2 (E)UH-4-6 (E)UH-4-9 (E)UH-4-10 (E)UH-4-8 (E)UH-4-7 S S S S S 5 4 4 4 4 4 5 5 5 EXISTING UNIT HEATER SCHEDULE TAG NO.GPM UH-4-1 3.8 UH-4-2 3.8 UH-4-3 3.8 UH-4-4 3.8 UH-4-5 3.8 NORTH EXISTING UNIT HEATER SCHEDULE TAG NO.GPM UH-4-1 3.8 UH-4-2 3.8 UH-4-3 3.8 UH-4-4 3.8 UH-4-5 3.8 REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 PARTIAL ROOF FLOOR PLAN - NEW WORK -HVAC H-206B 190306 RFG BMA 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor Hall1/8" = 1'-0" 1 PARTIAL FIFTH FLOOR ROOF PLAN - NEW WORK - HVAC DRAWING NOTES 1 PROVIDE NEW REHEAT COIL CONTROL VALVE. 2 PROVIDE NEW CONTROLS AND CONTROL ACCESSORIES FOR EXISTING EXHAUST AIR FAN. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 3 EXISTING AIR HANDLING UNIT SYSTEM SHALL BE RECOMISSIONED AND ALL EXISTING CONTROLS SHALL BE REPLACED. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 4 PROVIDE NEW CONTROLS, CONTROL VALVE AND CONTROL ACCESSORIES FOR EXISTING UNIT HEATER. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 5 PROVIDE NEW TEMPERATURE SENSOR. GENERAL NOTES A. CONTRACTOR SHALL DISCONNECT AND REMOVE 120V CONNECTION FROM EXISTING CONTROL PANELS AND EXTEND & REWORK AS REQUIRED TO NEW CONTROL PANELS. WIRING SHALL BE (2)#12AWG & (1)*12EG IN 3/4" CONDUIT. B. DISCONNECT AND REMOVE ALL PNEUMATIC (COMPRESSED AIR) TUBING/PIPING AND ACCESSORIES BACK TO MAIN AND CAP AIR TIGHT. IF MATERIAL IS POLY, PROVIDE BRASS PLUG. TERMINATING BY BENDING END OF TUBING OR TERMINATING WITH A SHEETMETAL SCREW IS NOT ACCEPTABLE. THERE SHALL BE NO DEAD END BRANCH COMPRESSED AIR TUBING/PIPING. NTS A KEYPLAN - H-206B FOURTH FLOOR 60' -0" 3 H-300B (E)AHU-1 (E)24x36 (E)34x30 RETURN TO (E)RAF-2 (E)36x24 RETURN FROM (E)RAF-1 EXISTING OUTSIDE AIR INTAKE LOUVER (E)AAD AAD (E)36x24(E)18x48 (E)AAD (E)85x65 OUTSIDE AIR INTAKE PLENUM 1 1 10x10 2 F FOURTH FLOOR 60' -0" 1 H-300B 2 H-300B (E)24x36 (E)30x48 (E)36x24 (E)28x28 ECONOMIZER OUTSIDE AIR (E)AAD AAD (E)AAD AAD (E)74x22 ECONOMIZER OUTSIDE AIR 10x10 MINIMUM OUTSIDE AIR14x14 MINIMUM OUTSIDE AIR (E)85x65 OUTSIDE AIR INTAKE PLENUM (E)118x75 OUTSIDE AIR INTAKE PLENUM (E)AAD (E)AAD 1 1 1 1 (E)PLENUM SEAM (TYPICAL) (E)24x24 ACCESS DOOR (E)24x24 ACCESS DOOR FOURTH FLOOR 60' -0" 3 H-300B EXISTING OUTSIDE AIR INTAKE LOUVER(E)30x50 (E)36x24 RELIEF FROM (E)RAF-1 (E)AHU-2 (E)34x30 RETURN TO (E)RAF-2 (E)48x30 RETURN FROM (E)RAF-2 AAD (E)118x75 OUTSIDE AIR INTAKE PLENUM 3F14x14 (E)AAD 1 (E)AAD1 FOURTH FLOOR 60' -0" EXISTING OUTSIDE AIR INTAKE LOUVER (E)AAD 1 EXISTING OUTSIDE AIR INTAKE PLENUM (E)28x64 EXISTING COLUMN EXISTING STRUCTURAL STEEL AAD 12x12 (E)AHU-3 (E)64x28 6 H-300B (E)28x64 F (E)64x28 AAD 4 EXISTING STRUCTURAL STEEL EXISTING COLUMN (E)AHU-3 (E)AAD 5 4 H-300B EXISTING OUTSIDE AIR INTAKE PLENUM 12x12 6 H-300B 4 H-300B (E)28x64 (E)64x28 EXISTING STRUCTURAL STEEL EXISTING COLUMN (E)AHU-3 (E)AAD 2 EXISTING OUTSIDE AIR INTAKE PLENUM 1 FOURTH FLOOR 60' -0" EXISTING OUTSIDE AIR INTAKE LOUVER (E)AAD 1 EXISTING OUTSIDE AIR INTAKE PLENUM (E)28x64 EXISTING COLUMN EXISTING STRUCTURAL STEEL (E)AHU-3 (E)64x28 (E)AAD21 REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 SECTIONS -NEW WORK -HVAC H-300B 190306 Checker Author 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor Hall1/4" = 1'-0" 1 AHU-1 SECTION - NEW WORK - HVAC 1/4" = 1'-0" 3 AHU-1&2 SECTION - NEW WORK - HVAC 1/4" = 1'-0" 2 AHU-2 SECTION - NEW WORK - HVAC DRAWING NOTES 1 PROVIDE NEW ELECTRONIC DAMPER ACTUATORS ASSOCIATED WITH EXISTING AIR HANDLING UNIT SYSTEM. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 2 PROVIDE MINIMUM OUTSIDE AIRFLOW STATION FOR (E)AHU-1. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 3 PROVIDE MINIMUM OUTSIDE AIRFLOW STATION FOR (E)AHU-2. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 4 PROVIDE MINIMUM OUTSIDE AIRFLOW STATION FOR (E)AHU-3. REFER TO CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR FURTHER REQUIREMENTS. 5 RELOCATE AND REINSTALL EXISTING OUTSIDE AIR INTAKE DAMPER. GENERAL NOTES A. CONTRACTOR SHALL DISCONNECT AND REMOVE 120V CONNECTION FROM EXISTING CONTROL PANELS AND EXTEND & REWORK AS REQUIRED TO NEW CONTROL PANELS. WIRING SHALL BE (2)#12AWG & (1)*12EG IN 3/4" CONDUIT. B. DISCONNECT AND REMOVE ALL PNEUMATIC (COMPRESSED AIR) TUBING/PIPING AND ACCESSORIES BACK TO MAIN AND CAP AIR TIGHT. IF MATERIAL IS POLY, PROVIDE BRASS PLUG. TERMINATING BY BENDING END OF TUBING OR TERMINATING WITH A SHEETMETAL SCREW IS NOT ACCEPTABLE. THERE SHALL BE NO DEAD END BRANCH COMPRESSED AIR TUBING/PIPING. 1/4" = 1'-0" 6 AHU-3 SECTION 01 - NEW WORK - HVAC 1/4" = 1'-0" 7 AHU-3 SECTION 02 - NEW WORK - HVAC 1/4" = 1'-0" 5 AHU-3 SECTION 02 - DEMOLITION - HVAC 1/4" = 1'-0" 4 AHU-3 SECTION 01 - DEMOLITION - HVAC DEMOLITION NOTES 1 DISCONNECT AND REMOVE EXISTING DAMPER ACTUATOR. 2 DISCONNECT AND RELOCATE EXISTING OUTSIDE AIR INTAKE DAMPER. THIRD FLOOR SECOND FLOOR FIRST FLOOR GROUND FLOOR BASEMENT G70 --- BUILDING 2021A - MYRON TAYLOR HALL ADDITION 170 --- BUILDING 2021 - MYRON TAYLOR HALL G20 --- B20 --- B20A --- B20B --- B0021 --- B0020 --- B0042 --- B0064 --- B0045 --- G0021 --- G0020 --- G0061 --- G0062 --- (E)RHC-14 (E)RHC-13 (E)RHC-15 EAST RISERS (E)RHC-10 (E)RHC-9 (E)RHC-12 (E)RHC-11 (E)AHU-4 (E)AHU-5 (E)EF-1 (E)Q-DOT HEAT RECOVERYWEST RISERS TO HUGHES HALL 194 --- 279 --- 277 --- 276 --- 10055 --- 193 --- 10067 --- (E)RHC-17 (E)RHC-16 (E)RHC-1 (E)RHC-2 (E)RHC-3 (E)RHC-4 (E)RHC-5 (E)RHC-6 (E)RHC-8 (E)RHC-7 370 --- G70A --- G70B --- THIRD FLOOR (E)AHU-2 (E)RAF-2 FOURTH FLOORFOURTH FLOOR MECH PENTHOUSE SECOND FLOOR FIRST FLOOR GROUND FLOOR 470 --- 270A --- 260 --- 260A --- 260B --- 377 --- 352 --- 370B --- 370A --- (E)EF-1 COPIER EXHAUST 373 --- 372 --- 350 --- 374 --- 376 --- 375 --- 376A --- TO HUGHES HALL REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 AIRFLOW DIAGRAM -HVAC H-400B 190306 RFG BMA 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor HallNTS 1 AHU-2, AHU-4, AHU-5 & EF-1 AIRFLOW DIAGRAM AHU-1 SYSTEM DESCRIPTION EXISTING VARIABLE VOLUME SINGLE ZONE AIR HANDLING UNIT (AHU-1) EXISTING ZONE RETURN FAN (RAF-1) (EXISTING CONTROL POINTS ARE SHOWN DASHED AND NEW CONTROL POINTS ARE SHOWN SOLID ON THE CONTROL DIAGRAM) GENERAL EXISTING SYSTEM SHALL BE PROVIDED WITH NEW CONTROL POINTS. ALL EXISTING CONTROL POINTS SHALL BE REMOVED AND REPLACED. SYSTEM SHALL BE CONTROLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). ALL SETPOINTS SHALL BE ADJUSTABLE. DURING HEATING MODE, THE HEATING CONTROL VALVES SHALL CONTINUE TO CONTROL WHEN THE FAN IS OFF FOR CONTINUED FREEZE PROTECTION. SETPOINTS SPACE COOLING TEMPERATURE SETPOINTS: OCCUPIED: 75 °F OCCUPIED SETBACK: 78 °F UNOCCUPIED: 81 °F SPACE HEATING TEMPERATURE SETPOINTS: OCCUPIED: 70 °F OCCUPIED SETBACK: 67 °F UNOCCUPIED: 64 °F SUPPLY AIRFLOW RATE: 2,500 CFM MIN / 7,500 CFM MAX RETURN AIRFLOW RATE: 2,300 CFM MIN / 7,300 CFM MAX MIN OUTSIDE AIRFLOW RATE: 200 CFM MIN / 1,125 CFM MAX RETURN CARBON DIOXIDE: 900 PPM DEHUMIDIFICATION SETPOINT: 60% RH FILTER DIFFERENTIAL PRESSURE HIGH LIMIT: 1.0" W.C. RETURN FAN STATIC PRESSURE SENSOR IS FOR MONITORING PURPOSES ONLY, TO ENSURE THE RELIEF AIR CHAMBER REMAINS POSITIVELY PRESSURIZED. ZONE OCCUPANCY SCHEDULE: 6 AM TO 8 PM, MON-FRI (COORDINATE WITH OWNER) SPACE OCCUPANCY ZONE OCCUPANCY SHALL BE DETERMINED BASED ON A COMBINATION OF A TIME OF DAY SCHEDULE AND A SPACE OCCUPANCY SENSOR. DURING THE SCHEDULED OCCUPANCY PERIOD, THE ZONE SHALL BE INITIALLY INDEXED TO OCCUPIED AND OPERATE FOR A MINIMUM OF 30 MINUTES, AT WHICH TIME THE SPACE OCCUPANCY SENSOR SHALL INDEX THE SPACE BETWEEN OCCUPIED AND OCCUPIED SETBACK MODE. IF THE ZONE BECOMES OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, AS DETERMINED BY THE SPACE OCCUPANCY SENSOR, THE ZONE SHALL BE INDEXED TO OCCUPIED FOR THE DURATION OF OCCUPANCY, THE ZONE SHALL INDEX BACK TO UNOCCUPIED WHEN OCCUPANCY IS NOT SENSED FOR A PERIOD OF 30 MINUTES. ZONE TEMPERATURE & FAN SPEED CONTROL TEMPERATURE SETPOINTS SHALL BE DETERMINED BASED ON A COMBINATION OF PROGRAMMED SCHEDULE AND SPACE OCCUPANCY SENSORS. OCCUPIED HEATING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD AND THE ZONE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING TEMPERATURE SETPOINT, THE UNIT FANS SHALL INDEX TO MINIMUM POSITION, THE REHEAT COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. IF THE SPACE TEMPERATURE SETPOINT IS STILL NOT MET AT MINIMUM SPEED AND REHEAT CONTROL VALVE FULLY OPEN, THEN THE UNIT FANS SHALL MODULATE BETWEEN MINIMUM AND MAXIMUM SPEED TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. OCCUPIED COOLING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD AND THE ZONE TEMPERATURE RISES ABOVE THE OCCUPIED COOLING TEMPERATURE SETPOINT, THE CHILLED WATER COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE DISCHARGE AIR TEMPERATURE OF 55°F. THE UNIT FANS SHALL MODULATE BETWEEN MINIMUM AND MAXIMUM POSITIONS AS NEEDED TO MAINTAIN THE SPACE TEMPERATURE AT SETPOINT. OCCUPIED HEATING SETBACK: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD AND THE ZONE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING SETBACK TEMPERATURE SETPOINT, THE UNIT FANS SHALL START AND INDEX TO MINIMUM POSITION, THE REHEAT COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. IF THE SPACE TEMPERATURE SETPOINT IS STILL NOT MET AT MINIMUM SPEED AND REHEAT CONTROL VALVE FULLY OPEN, THEN THE UNIT FANS SHALL MODULATE BETWEEN MINIMUM AND MAXIMUM SPEED TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. OCCUPIED COOLING SETBACK: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD AND THE ZONE TEMPERATURE RISES ABOVE THE OCCUPIED COOLING SETBACK TEMPERATURE SETPOINT, THE CHILLED WATER COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE DISCHARGE AIR TEMPERATURE OF 55°F, THE UNIT FANS SHALL START AND MODULATE BETWEEN MINIMUM AND MAXIMUM POSITIONS AS NEEDED TO MAINTAIN THE SPACE TEMPERATURE AT SETPOINT. UNOCCUPIED HEATING: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD AND THE ZONE TEMPERATURE FALLS BELOW THE UNOCCUPIED HEATING TEMPERATURE SETPOINT, THE UNIT FANS SHALL START AND INDEX TO MINIMUM POSITION AND THE UNIT REHEAT COIL CONTROL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN SETPOINT. IF THE SPACE TEMPERATURE SETPOINT IS STILL NOT MET AT MINIMUM SPEED AND REHEAT CONTROL VALVE FULLY OPEN, THEN THE UNIT FANS SHALL MODULATE BETWEEN MINIMUM AND MAXIMUM SPEED TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. ZONE TEMPERATURE & FAN SPEED CONTROL UNOCCUPIED COOLING: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD AND THE ZONE TEMPERATURE RISES ABOVE THE UNOCCUPIED COOLING TEMPERATURE SETPOINT, THE CHILLED WATER COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE DISCHARGE AIR TEMPERATURE OF 55°F, THE UNIT FANS SHALL START AND MODULATE BETWEEN MINIMUM AND MAXIMUM POSITIONS AS NEEDED TO MAINTAIN THE SPACE TEMPERATURE AT SETPOINT. IF THE ZONE BECOMES OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED MODE FOR THE DURATION OF OCCUPANCY. WHEN THE ZONE BECOMES UNOCCUPIED AGAIN DURING THE SCHEDULED UNOCCUPIED PERIOD, THE ZONE SHALL INDEX BACK TO UNOCCUPIED MODE. THE COOLING COIL CONTROL VALVE SHALL BE CLOSED WHEN THE SYSTEM FANS ARE OFF. START/STOP DURING THE SCHEDULED OCCUPANCY PERIOD, THE SYSTEM SHALL START BASED ON A TIME OF DAY SCHEDULE AND AN OPTIMUM START CONTROL ALGORITHM. THE ALGORITHM SHALL, AS A MINIMUM, BE A FUNCTION OF THE DIFFERENCE BETWEEN SPACE TEMPERATURE AND THE OCCUPIED SETPOINT AND THE AMOUNT OF TIME PRIOR TO THE SCHEDULED OCCUPANCY. WHEN THE SYSTEM STARTS, IT SHALL INITIALLY OPERATE FOR A MINIMUM OF 30 MINUTES. THE SYSTEM SHALL BE OFF WHEN THE SPACE IS IN OCCUPIED SETBACK OR UNOCCUPIED MODE, UNLESS THE SYSTEM IS NEEDED TO MAINTAIN THE OCCUPIED SETBACK OR UNOCCUPIED TEMPERATURE SETPOINTS. VENTILATION DAMPER CONTROL WHEN THE SPACE IS UNOCCUPIED, THE MINIMUM OUTSIDE AIR DAMPER, OUTSIDE AIR DAMPER AND RELIEF AIR DAMPER SHALL BE CLOSED, THE RETURN AIR DAMPER SHALL BE OPEN. WHEN THE SPACE IS OCCUPIED THE MINIMUM OUTSIDE AIR DAMPER SHALL OPEN TO MINIMUM POSITION AND THEN MODULATE AS NEEDED TO MAINTAIN THE CARBON DIOXIDE LEVEL AT SETPOINT. WHEN THE MINIMUM OUTSIDE AIR DAMPER IS FULLY OPEN AND THE VENTILATION AIRFLOW IS BELOW SETPOINT, THE RETURN AIR DAMPER SHALL MODULATE CLOSED AS NEEDED TO MAINTAIN SETPOINT. WHEN THE RETURN AIR DAMPER IS FULLY OPEN AND THE VENTILATION AIRFLOW IS ABOVE SETPOINT, THE MINIMUM OUTSIDE AIR DAMPER SHALL MODULATE CLOSED AS NEEDED TO MAINTAIN SETPOINT. RETURN FAN CONTROL THE RETURN AIR FAN SHALL MODULATE AS NEEDED TO MATCH THE SUPPLY AIRFLOW MINUS 200 CFM. ECONOMIZER CONTROL THE SYSTEM SHALL BE EQUIPED WITH BOTH MODULATED AND DIFFERENTIAL DRY BULB INTEGRATED ECONOMIZER CONTROL SEQUENCES. MODULATED ECONOMIZER MODE (MAT CONTROL): WHEN THE RETURN AIR TEMPERATURE RISES ABOVE THE COOLING SETPOINT, AND THE OUTSIDE AIR TEMPERATURE IS LESS THAN 55°F, MODULATED ECONOMIZER MODE (MAT CONTROL) SHALL BE INITITATED. THE OUTSIDE AIR DAMPER, RETURN AND RELIEF AIR DAMPERS SHALL MODULATE TO MAINTAIN THE MIXED AIR TEMPERATURE SETPOINT OF 55°F. LOW LIMIT: WHEN THE MIXED AIR TEMPERATURE FALLS BELOW SETPOINT, THE OUTSIDE AIR, RELIEF AIR DAMPER SHALL MODULATE TO MINIMUM POSITION AND THE RETURN AIR DAMPER SHALL INDEX TO MAXIMUM AND THE SYSTEM HEATING MODE SHALL BE INITITATED. HIGH LIMIT: WHEN THE MIXED AIR TEMPERATURE RISES ABOVE SETPOINT, THE OUTSIDE AIR AND RELIEF AIR DAMPERS SHALL INDEX TO FULL OPEN, THE RETURN AIR DAMPER SHALL CLOSE AND INTEGRATED EONOMIZER MODE SHALL BE INITITATED. INTEGRATED ECONOMIZER MODE: WHEN THE RETURN AIR TEMPERATURE IS ABOVE THE OUTDOOR AIR TEMPERATURE AND THE OUTDOOR AIR DEWPOINT TEMPERATURE IS BELOW 60°F, INTEGRATED ECONOMIZER MODE SHALL BE INITITATED. THE OUTSIDE AND RELIEF DAMPERS SHALL OPEN AND THE RETURN AIR DAMPER SHALL BE CLOSED, THE CHILLED WATER CONTROL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SETPOINT. LOW LIMIT SHUTOFF: INTEGRATED ECONOMIZER CONTROL SHALL BE DISABLED AND MODULATED ECONOMIZER SHALL BE INITITIATED WHEN THE OUTSIDE AIR TEMPERATURE FALLS BELOW 55°F. HIGH LIMIT SHUTOFF: INTEGRATED ECONOMIZER CONTROL SHALL BE DISABLED WHEN THE OUTDOOR AIR TEMPERATURE EXCEEDS THE RETURN AIR TEMPERATURE. THE OUTSIDE AIR, RELIEF AIR AND RETURN AIR DAMPERS SHALL INDEX TO CO2 CONTROL AND COOLING MODE SHALL BE INITITIATED. DEHUMIDIFICATION CONTROL WHEN THE SPACE HUMIDITY EXCEEDS SETPOINT, AS SENSED BY THE SPACE HUMIDITY SENSOR, DEHUMIDIFICATION CONTROL SHALL BE ENABLED. THE CHILLED WATER CONTROL VALVE SHALL MODULATE OPEN AS REQUIRED TO MAINTAIN THE SPACE HUMIDITY SETPOINT. IF THE SPACE TEMPERATURE DROPS BELOW THE SPACE TEMPERATURE SETPOINT, THE REHEAT COIL CONTROL VAVLE SHALL MODULATE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE SETPOINT. SAFETIES FREEZE PROTECTION: THE SUPPLY AND RETURN AIR FANS SHALL SHUT DOWN, THE OUTSIDE AIR AND EXHAUST AIR DAMPERS SHALL CLOSE, AND THE CONTROL VALVES SHALL OPEN UPON ACTIVATION OF THE LOW LIMIT TEMPERATURE SWITCH. TYPICAL ASD CONTROL / MONITORING POINTS ASDSS R SC M AOM OCCUPANCY SENSOR OS BO BACnet / MSTP: - AV: POWER (KW) - AV: SPEED (RPM) R COM COMBO TEMP/RH/ CARBON DIOXIDE SENSOR AV SETPOINT(E)WIRE TO FIRE ALARM SYSTEM AO BI (E)OUTSIDE AIR CONDITIONS REFER TO PLANS T AI AI H co2 AI SAI AV SETPOINT AV SETPOINT BI AV DEWPOINTAI HT AI SF T AIAV SETPOINTAI F M ASD H C REHEAT COIL C C T AI FZ BI (E)AHU-1 N.O. E AO REHEAT COIL CONTROL VALVE N.C. E AO COOLING COIL CONTROL VALVE CWR CWS HWR HWS (E)TO FAN CIRCUIT MOD MOD AO AI F AO N.C. MINIMUM OUTSIDE AIR OUTSIDE AIR RA RETURN AIR MOD AO RA OA MA MOD AO EARELIEF AIR N.C. RA RF MONITORING POINT ONLY RETURN AIR T AI P (E)FILTER BANK COOLING COIL INDICATES EXISTING AI F NEW FAN INLET AIRFLOW STATION AISP AI AV SETPOINT N.O. T AI RA SD BI (E)RAF-1 AOM (E)WIRE TO FIRE ALARM SYSTEM SUPPLY AIRSA NEW FAN INLET AIRFLOW STATION SEQUENCE OF OPERATION M ASD D POINT SCHEDULE EXISTING AIR HANDLING UNIT AHU-1 HARDWARE POINTS SOFTWARE POINTS SHOWN ON GRAPHIC NOTESBIBOAIAOAV BV SCH TREND ALARM BACS EMCS DESCRIPTION STEAM LOAD SHED X (6)BINARY NETWORK INPUTS FROM EMCS CHILLED WATER LOAD SHED X (4)BINARY NETWORK INPUTS FROM EMCS OUTSIDE AIR TEMPERATURE X X X IF NOT PROVIDED GLOBALLY OUTSIDE AIR RELATIVE HUMIDITY X X IF NOT PROVIDED GLOBALLY OUTSIDE AIR DEWPOINT X X X IF NOT PROVIDED GLOBALLY OUTSIDE AIR DAMPER POSITION COMMAND X X MINIMUM OUTSIDE AIR DAMPER POSITION COMMAND X X MINIMUM OUTSIDE AIR FLOW X X X RETURN AIR DAMPER POSITION COMMAND X X RETURN FAN DISCHARGE AIR STATIC PRESSURE X X X MONITORING POINT ONLY RELIEF AIR DAMPER POSITION COMMAND X X FILTER DIFFERENTIAL PRESSURE X X X X HIGH LIMIT X MIXED AIR TEMPERATURE X X X AVERAGING SENSOR MIXED AIR TEMPERATURE SETPOINT X X X LOW LIMIT TEMPERATURE STATUS X X X LOW LIMIT X COOLING COIL VALVE POSITION COMMAND X X X X 5o DELTA T ACROSS COIL WITH VALVE COMMANDED CLOSED X COOLING COIL DISCHARGE AIR TEMPERATURE X X X X + / - 4 DEG F FROM SETPOINT X AVERAGING SENSOR PREHEAT COIL VALVE POSITION COMMAND X X X X 5o DELTA T ACROSS COIL WITH VALVE COMMANDED CLOSED X SUPPLY FAN MOTOR START/STOP X X X X INTERLOCK WITH FA SYSTEM SUPPLY FAN SPEED COMMAND X X X SUPPLY FAN STATUS X X X FAILURE X VIA CONTACT ON DRIVE SUPPLY FAN POWER (kW)X X X BACnet MSTP NETWORK POINT SUPPLY FAN SPEED (RPM)X X X BACnet MSTP NETWORK POINT SUPPLY FAN AIRFLOW X X X INSTALL IN INLET CONE AHU DISCHARGE AIR TEMPERATURE X X X X + / - 4 DEG F FROM SETPOINT X AHU DISCHARGE AIR TEMPERATURE SETPOINT X X X RETURN DUCT SMOKE DETECTOR STATUS X X RETURN AIR TEMPERATURE X X X RETURN FAN MOTOR START/STOP X X X X INTERLOCK WITH FA SYSTEM RETURN FAN SPEED COMMAND X X X RETURN FAN STATUS X X X FAILURE X VIA CONTACT ON DRIVE RETURN FAN POWER (kW)X X X BACnet MSTP NETWORK POINT RETURN FAN SPEED (RPM)X X X BACnet MSTP NETWORK POINT RETURN FAN AIRFLOW X X X INSTALL IN INLET CONE ZONE TEMPERATURE SETPOINT X X X ZONE TEMPERATURE X X X +/- 4 DEG F FROM SETPOINT X REFER TO PLANS ZONE RELATIVE HUMIDITY X X X REFER TO PLANS ZONE RELATIVE HUMIDITY SETPOINT X X X ZONE CARBON DIOXIDE SETPOINT X X X ZONE CARBON DIOXIDE X X X +/- 4 DEG F FROM SETPOINT X REFER TO PLANS ZONE OCCUPANCY X X X REFER TO PLANS INDICATES EXISTING POINT SCHEDULE FIN TUBE RADIATION HARDWARE POINTS SOFTWARE POINTS SHOWN ON GRAPHIC NOTESBIBOAIAOAV BV SCH TREND ALARM BACS EMCS DESCRIPTION BASEBOARD RADIATION CONTROL VALVE POSITION COMMAND X X X FAIL LAST ZONE TEMPERATURE SETPOINT X X X ZONE TEMPERATURE X X X +/- 4 DEG F FROM SETPOINT X REFER TO PLANS ZONE RELATIVE HUMIDITY SETPOINT X X X ZONE RELATIVE HUMIDITY X X X MONITORING POINT ONLY SA D T AI AI H AV SETPOINT REFER TO PLANS HWR F.L. E FTR CONTROL VALVE AO HWS COMBO TEMP/RH SENSOR SYSTEM DESCRIPTION BASEBOARD RADIATION HEATING GENERAL EXISTING ZONE SHALL BE PROVIDED WITH NEW CONTROL POINTS. ALL EXISTING CONTROL POINTS SHALL BE REMOVED AND REPLACED. SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). ALL SETPOINTS SHALL BE ADJUSTABLE. SETPOINTS SPACE HEATING TEMPERATURE SETPOINTS: OCCUPIED: 70 °F OCCUPIED SETBACK: 67 °F UNOCCUPIED: 64 °F ZONE TEMPERATURE CONTROL IF THE ZONE TEMPERATURE FALLS BELOW THE HEATING TEMPERATURE SETPOINT, THE BASEBOARD RADIATION CONTROL VALVE SHALL MODULATE TO MAINTAIN TEMPERATURE SETPOINT. SEQUENCE OF OPERATION REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 CONTROL SCHEMATIC & SYSTEM SUMMARY H-500B 190306 RFG RFG 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor HallNTS 1 EXISTING AIR HANDLING UNIT AHU-1 & EXISTING RETURN AIR FAN RAF-1 CONTROL SCHEMATIC AND SYSTEM SUMMARY NTS 2 BASEBOARD FIN TUBE RADIATION CONTROL SCHEMATIC & SYSTEM SUMMARY AHU-2 SYSTEM DESCRIPTION EXISTING VARIABLE VOLUME AIR HANDLING UNIT (AHU-2) EXISTING ZONE RETURN FAN (RAF-2) (EXISTING CONTROL POINTS ARE SHOWN DASHED AND NEW CONTROL POINTS ARE SHOWN SOLID ON THE CONTROL DIAGRAM) GENERAL EXISTING SYSTEM SHALL BE PROVIDED WITH NEW CONTROL POINTS. ALL EXISTING CONTROL POINTS SHALL BE REMOVED AND REPLACED. SYSTEM SHALL BE CONTROLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). ALL SETPOINTS SHALL BE ADJUSTABLE. DURING HEATING MODE, THE HEATING CONTROL VALVES SHALL CONTINUE TO CONTROL WHEN THE FAN IS OFF FOR CONTINUED FREEZE PROTECTION. SETPOINTS SPACE COOLING TEMPERATURE SETPOINTS: OCCUPIED: 75 °F OCCUPIED SETBACK: 78 °F UNOCCUPIED: 81 °F SPACE HEATING TEMPERATURE SETPOINTS: OCCUPIED: 70 °F OCCUPIED SETBACK: 67 °F UNOCCUPIED: 64 °F AIR HANDLING DISCHARGE AIR TEMPERATURE SETPOINT: 57 °F SUPPLY AIRFLOW RATE: 6,000 CFM MIN / 18,075 CFM MAX RETURN AIRFLOW RATE: 4,320 CFM MIN / 16,395 CFM MAX MIN OUTSIDE AIRFLOW RATE: 1,680 CFM MIN / 2,550 CFM MAX RETURN CARBON DIOXIDE: 900 PPM DEHUMIDIFICATION SETPOINT: 55% RH FILTER DIFFERENTIAL PRESSURE HIGH LIMIT: 1.0" W.C. RETURN FAN STATIC PRESSURE SENSOR IS FOR MONITORING PURPOSES ONLY, TO ENSURE THE RELIEF AIR CHAMBER REMAINS POSITIVELY PRESSURIZED. ZONE OCCUPANCY SCHEDULE: 6 AM TO 8 PM, MON-FRI (COORDINATE WITH OWNER) SPACE OCCUPANCY ZONE OCCUPANCY SHALL BE DETERMINED BASED ON A COMBINATION OF A TIME OF DAY SCHEDULE AND A SPACE OCCUPANCY SENSOR. DURING THE SCHEDULED OCCUPANCY PERIOD, THE ZONE SHALL BE INITIALLY INDEXED TO OCCUPIED AND OPERATE FOR A MINIMUM OF 30 MINUTES, AT WHICH TIME THE SPACE OCCUPANCY SENSOR SHALL INDEX THE SPACE BETWEEN OCCUPIED AND OCCUPIED SETBACK MODE. IF THE ZONE BECOMES OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, AS DETERMINED BY THE SPACE OCCUPANCY SENSOR, THE ZONE SHALL BE INDEXED TO OCCUPIED FOR THE DURATION OF OCCUPANCY, THE ZONE SHALL INDEX BACK TO UNOCCUPIED WHEN OCCUPANCY IS NOT SENSED FOR A PERIOD OF 30 MINUTES. ZONE OCCUPANCY SHALL BE BASED ON OCCUPANCY INPUTS FROM ANY SPACE OCCUPANCY SENSOR ASSOCIATED WITH ALL ZONES BEING SERVED FROM THE AIR HANDLING UNIT SYSTEM. ZONE TEMPERATURE & FAN SPEED CONTROL TEMPERATURE SETPOINTS SHALL BE DETERMINED BASED ON A COMBINATION OF PROGRAMMED SCHEDULE AND ZONE OCCUPANCY. ZONE TEMPERATURE SHALL BE DETERMINED BASED ON THE SPACE TEMPERATURE ASSOCIATED WITH THAT ZONE. THE AIR HANDLING UNIT FAN SPEEDS SHALL BE DETERMINED BASED ON THE WORSE CASE ZONE TEMPERATURE SENSOR. OCCUPIED HEATING: IF THE ZONE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD AND ALL OF THE ZONE TEMPERATURES FALL BELOW THE OCCUPIED HEATING TEMPERATURE SETPOINT, THE UNIT FANS SHALL INDEX TO MINIMUM POSITION, THE REHEAT COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE SETPOINTS. OCCUPIED COOLING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD AND ANY OF THE ZONE TEMPERATURES RISE ABOVE THE OCCUPIED COOLING TEMPERATURE SETPOINT, THE CHILLED WATER COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SETPOINT. THE UNIT FANS SHALL MODULATE BETWEEN MINIMUM AND MAXIMUM POSITIONS AS NEEDED TO MAINTAIN THE SPACE TEMPERATURE AT SETPOINTS. OCCUPIED HEATING SETBACK: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD AND ALL OF THE ZONE TEMPERATURES FALL BELOW THE OCCUPIED HEATING SETBACK TEMPERATURE SETPOINT, THE UNIT FANS SHALL INDEX TO MINIMUM POSITION, THE REHEAT COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE SETPOINTS. OCCUPIED COOLING SETBACK: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD AND ANY OF THE ZONE TEMPERATURES RISE ABOVE THE OCCUPIED COOLING SETBACK TEMPERATURE SETPOINT, THE CHILLED WATER COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SETPOINT, THE UNIT FANS SHALL MODULATE BETWEEN MINIMUM AND MAXIMUM POSITIONS AS NEEDED TO MAINTAIN THE SPACE TEMPERATURE AT SETPOINTS. UNOCCUPIED HEATING: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD AND ANY OF THE ZONE TEMPERATURES FALL BELOW THE UNOCCUPIED HEATING TEMPERATURE SETPOINT, THE UNIT FANS SHALL START AND INDEX TO MINIMUM POSITION AND THE REHEAT COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE SETPOINTS. TYPICAL ASD CONTROL / MONITORING POINTS ASDSS R SC M AOM OCCUPANCY SENSOR OS BO BACnet / MSTP: - AV: POWER (KW) - AV: SPEED (RPM) R COM COMBO TEMP/RH SENSOR (E)WIRE TO FIRE ALARM SYSTEM AO BI (E)OUTSIDE AIR CONDITIONS REFER TO PLANS T AI AI H AV SETPOINT AV SETPOINT BI AV DEWPOINTAI HT AI SF T AIAV SETPOINTAI F M ASD C C T AI FZ BI (E)AHU-2 N.C. E AO COOLING COIL CONTROL VALVE CWR CWS (E)TO FAN CIRCUIT MOD MOD AO AI F AO N.C. MINIMUM OUTSIDE AIR OUTSIDE AIR RA RETURN AIR MOD AO RA OA MA MOD AO EARELIEF AIR N.C. RA RF MONITORING POINT ONLY RETURN AIR T AI P (E)FILTER BANK COOLING COIL INDICATES EXISTING AI F NEW FAN INLET AIRFLOW STATION AI SP AI AV SETPOINT N.O. T AI co2 AI SAI RA SD BI (E)RAF-2 AOM (E)WIRE TO FIRE ALARM SYSTEM SA NEW FAN INLET AIRFLOW STATION ZONE TEMPERATURE & FAN SPEED CONTROL UNOCCUPIED COOLING: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD AND ANY OF THE ZONE TEMPERATURES RISE ABOVE THE UNOCCUPIED COOLING TEMPERATURE SETPOINT, THE CHILLED WATER COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SETPOINT, THE UNIT FANS SHALL START AND MODULATE BETWEEN MINIMUM AND MAXIMUM POSITIONS AS NEEDED TO MAINTAIN THE SPACE TEMPERATURE SETPOINTS. IF ANY OF THE ZONES BECOME OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SYSTEM SHALL INDEX TO OCCUPIED MODE FOR THE DURATION OF OCCUPANCY. WHEN ALL OF THE ZONES BECOME UNOCCUPIED AGAIN DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SYSTEM SHALL INDEX BACK TO UNOCCUPIED MODE. THE COOLING COIL CONTROL VALVE SHALL BE CLOSED WHEN THE SYSTEM FANS ARE OFF. START/STOP DURING THE SCHEDULED OCCUPANCY PERIOD, THE SYSTEM SHALL START BASED ON A TIME OF DAY SCHEDULE AND AN OPTIMUM START CONTROL ALGORITHM. THE ALGORITHM SHALL, AS A MINIMUM, BE A FUNCTION OF THE DIFFERENCE BETWEEN SPACE TEMPERATURE AND THE OCCUPIED SETPOINT AND THE AMOUNT OF TIME PRIOR TO THE SCHEDULED OCCUPANCY. THE SYSTEM SHALL BE OFF WHEN THE SPACE IS IN UNOCCUPIED MODE, UNLESS THE SYSTEM IS NEEDED TO MAINTAIN THE UNOCCUPIED TEMPERATURE SETPOINTS. VENTILATION DAMPER CONTROL WHEN THE SPACE IS UNOCCUPIED, THE MINIMUM OUTSIDE AIR DAMPER, OUTSIDE AIR DAMPER AND RELIEF AIR DAMPER SHALL BE CLOSED, THE RETURN AIR DAMPER SHALL BE OPEN. WHEN THE SPACE IS OCCUPIED THE MINIMUM OUTSIDE AIR DAMPER SHALL OPEN TO MINIMUM POSITION AND THEN MODULATE AS NEEDED TO MAINTAIN THE CARBON DIOXIDE LEVEL AT SETPOINT. WHEN THE MINIMUM OUTSIDE AIR DAMPER IS FULLY OPEN AND THE VENTILATION AIRFLOW IS BELOW SETPOINT, THE RETURN AIR DAMPER SHALL MODULATE CLOSED AS NEEDED TO MAINTAIN SETPOINT. WHEN THE RETURN AIR DAMPER IS FULLY OPEN AND THE VENTILATION AIRFLOW IS ABOVE SETPOINT, THE MINIMUM OUTSIDE AIR DAMPER SHALL MODULATE CLOSED AS NEEDED TO MAINTAIN SETPOINT. RETURN FAN CONTROL THE RETURN AIR FAN SHALL MODULATE AS NEEDED TO MATCH THE SUPPLY AIRFLOW MINUS 1,680 CFM (HEAT RECOVERY EXHAUST FAN EF-1 = 1480 + COPIER EXHAUST EF-1 = 200). ECONOMIZER CONTROL THE SYSTEM SHALL BE EQUIPED WITH BOTH MODULATED AND DIFFERENTIAL DRY BULB INTEGRATED ECONOMIZER CONTROL SEQUENCES. MODULATED ECONOMIZER MODE (MAT CONTROL): WHEN THE RETURN AIR TEMPERATURE RISES ABOVE THE COOLING SETPOINT, AND THE OUTSIDE AIR TEMPERATURE IS LESS THAN 55°F, MODULATED ECONOMIZER MODE (MAT CONTROL) SHALL BE INITITATED. THE OUTSIDE AIR DAMPER, RETURN AND RELIEF AIR DAMPERS SHALL MODULATE TO MAINTAIN THE MIXED AIR TEMPERATURE SETPOINT OF 55°F. LOW LIMIT: WHEN THE MIXED AIR TEMPERATURE FALLS BELOW SETPOINT, THE OUTSIDE AIR, RELIEF AIR DAMPER SHALL MODULATE TO MINIMUM POSITION AND THE RETURN AIR DAMPER SHALL INDEX TO MAXIMUM AND THE SYSTEM HEATING MODE SHALL BE INITITATED. HIGH LIMIT: WHEN THE MIXED AIR TEMPERATURE RISES ABOVE SETPOINT, THE OUTSIDE AIR AND RELIEF AIR DAMPERS SHALL INDEX TO FULL OPEN, THE RETURN AIR DAMPER SHALL CLOSE AND INTEGRATED EONOMIZER MODE SHALL BE INITITATED. INTEGRATED ECONOMIZER MODE: WHEN THE RETURN AIR TEMPERATURE IS ABOVE THE OUTDOOR AIR TEMPERATURE AND THE OUTDOOR AIR DEWPOINT TEMPERATURE IS BELOW 60°F, INTEGRATED ECONOMIZER MODE SHALL BE INITITATED. THE OUTSIDE AND RELIEF DAMPERS SHALL OPEN AND THE RETURN AIR DAMPER SHALL BE CLOSED, THE CHILLED WATER CONTROL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SETPOINT. LOW LIMIT SHUTOFF: INTEGRATED ECONOMIZER CONTROL SHALL BE DISABLED AND MODULATED ECONOMIZER SHALL BE INITITIATED WHEN THE OUTSIDE AIR TEMPERATURE FALLS BELOW 55°F. HIGH LIMIT SHUTOFF: INTEGRATED ECONOMIZER CONTROL SHALL BE DISABLED WHEN THE OUTDOOR AIR TEMPERATURE EXCEEDS THE RETURN AIR TEMPERATURE. THE OUTSIDE AIR, RELIEF AIR AND RETURN AIR DAMPERS SHALL INDEX TO CO2 CONTROL AND COOLING MODE SHALL BE INITITIATED. DEHUMIDIFICATION CONTROL WHEN THE SPACE HUMIDITY EXCEEDS SETPOINT, AS SENSED BY THE SPACE HUMIDITY SENSOR, DEHUMIDIFCATION CONTROL SHALL BE ENABLED. THE CHILLED WATER CONTROL VALVE SHALL MODULATE OPEN AS REQUIRED TO MAINTAIN THE SPACE HUMIDITY SETPOINT. IF THE SPACE TEMPERATURE DROPS BELOW THE SPACE TEMPERATURE SETPOINT, THE REHEAT COIL CONTROL VAVLE SHALL MODULATE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE SETPOINT. SAFETIES FREEZE PROTECTION: THE SUPPLY AND RETURN AIR FANS SHALL SHUT DOWN, THE OUTSIDE AIR AND EXHAUST AIR DAMPERS SHALL CLOSE, AND THE CONTROL VALVES SHALL OPEN UPON ACTIVATION OF THE LOW LIMIT TEMPERATURE SWITCH. SEQUENCE OF OPERATION H C N.O. E REHEAT COIL CONTROL VALVE HWR HWS AO H C (E)RHC-10 N.O. E REHEAT COIL CONTROL VALVE HWR HWS AO H C N.O. E REHEAT COIL CONTROL VALVE HWR HWS AO H C (E)RHC-2 N.O. E REHEAT COIL CONTROL VALVE HWR HWS AO (E)RHC-9 (E)RHC-1 TO (E)RHC-11,12,13,14,15 TO (E)RHC-3,4,5,6,7,8 SA SA SA SD BI AOM (E)WIRE TO FIRE ALARM SYSTEM M ASD POINT SCHEDULE EXISTING AIR HANDLING UNIT AHU-2 HARDWARE POINTS SOFTWARE POINTS SHOWN ON GRAPHIC NOTESBIBOAIAOAV BV SCH TREND ALARM BACS EMCS DESCRIPTION STEAM LOAD SHED X (6)BINARY NETWORK INPUTS FROM EMCS CHILLED WATER LOAD SHED X (4)BINARY NETWORK INPUTS FROM EMCS OUTSIDE AIR TEMPERATURE X X X IF NOT PROVIDED GLOBALLY OUTSIDE AIR RELATIVE HUMIDITY X X IF NOT PROVIDED GLOBALLY OUTSIDE AIR DEWPOINT X X X IF NOT PROVIDED GLOBALLY OUTSIDE AIR DAMPER POSITION COMMAND X X MINIMUM OUTSIDE AIR DAMPER POSITION COMMAND X X MINIMUM OUTSIDE AIR FLOW X X X RETURN AIR DAMPER POSITION COMMAND X X RETURN FAN DISCHARGE AIR STATIC PRESSURE X X X MONITORING POINT ONLY RELIEF AIR DAMPER POSITION COMMAND X X FILTER DIFFERENTIAL PRESSURE X X X X HIGH LIMIT X MIXED AIR TEMPERATURE X X X AVERAGING SENSOR MIXED AIR TEMPERATURE SETPOINT X X X LOW LIMIT TEMPERATURE STATUS X X X LOW LIMIT X COOLING COIL VALVE POSITION COMMAND X X X X 5o DELTA T ACROSS COIL WITH VALVE COMMANDED CLOSED X COOLING COIL DISCHARGE AIR TEMPERATURE X X X X + / - 4 DEG F FROM SETPOINT X AVERAGING SENSOR SUPPLY FAN MOTOR START/STOP X X X X INTERLOCK WITH FA SYSTEM SUPPLY FAN SPEED COMMAND X X X SUPPLY FAN STATUS X X X FAILURE X VIA CONTACT ON DRIVE SUPPLY FAN POWER (kW)X X X BACnet MSTP NETWORK POINT SUPPLY FAN SPEED (RPM)X X X BACnet MSTP NETWORK POINT SUPPLY FAN AIRFLOW X X X INSTALL IN INLET CONE AHU DISCHARGE AIR TEMPERATURE X X X X + / - 4 DEG F FROM SETPOINT X AHU DISCHARGE AIR TEMPERATURE SETPOINT X X X SUPPLY DUCT SMOKE DETECTOR STATUS X X RETURN DUCT SMOKE DETECTOR STATUS X X RETURN AIR TEMPERATURE X X X RETURN AIR RELATIVE HUMIDITY X X X RETURN FAN MOTOR START/STOP X X X X INTERLOCK WITH FA SYSTEM RETURN FAN SPEED COMMAND X X X RETURN FAN STATUS X X X FAILURE X VIA CONTACT ON DRIVE RETURN FAN POWER (kW)X X X BACnet MSTP NETWORK POINT RETURN FAN SPEED (RPM)X X X BACnet MSTP NETWORK POINT RETURN FAN AIRFLOW X X X INSTALL IN INLET CONE RETURN RELATIVE HUMIDITY X X X RETURN RELATIVE HUMIDITY SETPOINT X X X REHEAT COIL VALVE POSITION COMMAND X X X X 5o DELTA T ACROSS COIL WITH VALVE COMMANDED CLOSED X TYPICAL OF 15 ZONE TEMPERATURE SETPOINT X X X ZONE TEMPERATURE X X X +/- 4 DEG F FROM SETPOINT X REFER TO PLANS ZONE CARBON DIOXIDE SETPOINT X X X ZONE CARBON DIOXIDE X X X +/- 4 DEG F FROM SETPOINT X REFER TO PLANS ZONE OCCUPANCY X X X REFER TO PLANS SYSTEM DESCRIPTION HOT WATER REHEAT COIL GENERAL EXISTING ZONE SHALL BE PROVIDED WITH NEW CONTROL POINTS. ALL EXISTING CONTROL POINTS SHALL BE REMOVED AND REPLACED. SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). ALL SETPOINTS SHALL BE ADJUSTABLE. SETPOINTS SPACE HEATING TEMPERATURE SETPOINTS: OCCUPIED: 70 0F OCCUPIED SETBACK: 670F UNOCCUPIED: 640F MINIMUM SPACE OCCUPANCY INDEX TIME: 30 MINUTES ZONE OCCUPANCY SCHEDULE: 6 AM TO 9 PM - MON-FRI, 8 AM TO 7:00 PM SAT- SUN (COORDINATE WITH OWNER) ZONE OCCUPANCY OCCUPANCY SHALL BE DETERMINED BASED ON A COMBINATION OF A TIME OF DAY SCHEDULE AND A SPACE OCCUPANCY SENSOR. DURING THE SCHEDULED OCCUPANCY PERIOD, THE ZONE SHALL BE INTITIALLY INDEXED TO OCCUPIED AND OPERATE FOR A MINIMUM OF 30 MINUTES. AT WHICH TIME, THE SPACE OCCUPANCY SENSOR SHALL INDEX THE SPACE BETWEEN OCCUPIED AND OCCUPIED SETBACK MODE. SEQUENCE OF OPERATION POINT SCHEDULE REHEAT COIL HARDWARE POINTS SOFTWARE POINTS SHOWN ON GRAPHIC NOTESBIBOAIAOAV BV SCH TREND ALARM BACS EMCS DESCRIPTION REHEAT COIL CONTROL VALVE POSITION COMMAND X X X 5 DEG F DT ACROSS COIL W/ VALVE COMMANDED CLOSED X FAIL LAST REHEAT COIL LEAVING AIR TEMPERATURE X X X ZONE TEMPERATURE SETPOINT X X X ZONE TEMPERATURE X X X +/- 4 DEG F FROM SETPOINT X REFER TO PLANS ZONE RELATIVE HUMIDITY SETPOINT X X X ZONE RELATIVE HUMIDITY X X X MONITORING POINT ONLY ZONE OCCUPANCY X X X ZONE H C REHEAT COIL T AI N.O. E AO REHEAT COIL CONTROL VALVE HWR HWS SUPPLY AIR FROM AHU-5 SA SA D T AI AI H AV SETPOINT COMBO TEMP/RH SENSOR (REFER TO PLANS) OSOCCUPANCY OR VACANCY SENSOR (ONLY WHERE INDICATED ON PLANS) BI ZONE OCCUPANCY CONT'D IF THE SPACE BECOMES OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, AS DETERMINED VIA THE OCCUPANCY SENSOR, THE ZONE SHALL BE INDEXED TO OCCUPIED FOR THE DURATION OF OCCUPANCY. THE ZONE SHALL INDEX BACK TO UNOCCUPIED WHEN OCCUPANCY IS NOT SENSED FOR A PERIOD OF 30 MINUTES. FOR ZONES WITH MULTIPLE SPACES, AND OCCUPANCY SENSOR SHALL BE PROVIDED IN EACH SPACE AND ZONE OCCUPANCY SHALL BE BASED ON OCCUPANCY INPUTS FROM ANY OF THE SPACE OCCUPANCY SENSORS ASSOCIATED WITH THAT ZONE. ZONE TEMPERATURE CONTROL TEMPERATURE SETPOINTS SHALL BE DETERMINED BASED ON A COMBINATION OF PROGRAMMED SCHEDULE AND ZONE OCCUPANCY. FOR ZONES WITH MULTIPLE SPACES, ZONE TEMPERATURE SHALL BE DETERMINED BASED ON AN AVERAGE OF ALL SPACE TEMPERATURES ASSOCIATED WITH THAT ZONE. OCCUPIED HEATING: IF THE ZONE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING TEMPERATURE SETPOINT DURING THE SCHEDULED OCCUPIED PERIOD, THE REHEAT COIL CONTROL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN SETPOINT. UNOCCUPIED HEATING: IF THE ZONE TEMPERATURE FALLS BELOW THE UNOCCUPIED HEATING TEMPERATURE SETPOINT DURING THE SCHEDULED UNOCCUPIED PERIOD, THE REHEAT COIL CONTROL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN SETPOINT. IF THE ZONE BECOMES OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE OCCUPIED HEATING SEQUENCE SHALL APPLY FOR THE DURATION OF OCCUPANCY. THE ZONE SHALL BE MAINTAINED AT THE OCCUPIED TEMPERATURE SETPOINTS. WHEN THE ZONE BECOMES UNOCCUPIED AGAIN DURING THE SCHEDULED UNOCCUPIED PERIOD, THE ZONE SHALL INDEX BACK TO UNOCCUPIED MODE. INDICATES EXISTING REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 CONTROL SCHEMATIC & SYSTEM SUMMARY H-501B 190306 RFG RFG 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor HallNTS 1 EXISTING AIR HANDLING UNIT AHU-2 & EXISTING RETURN AIR FAN RAF-2 CONTROL SCHEMATIC AND SYSTEM SUMMARY NTS 2 TYPICAL REHEAT COIL CONTROL SCHEMATIC & SYSTEM SUMMARY AHU-3 SYSTEM DESCRIPTION EXISTING VARIABLE VOLUME SINGLE ZONE AIR HANDLING UNIT (AHU-3) EXISTING ZONE RETURN FAN (RAF-3) (EXISTING CONTROL POINTS ARE SHOWN DASHED AND NEW CONTROL POINTS ARE SHOWN SOLID ON THE CONTROL DIAGRAM) GENERAL EXISTING SYSTEM SHALL BE PROVIDED WITH NEW CONTROL POINTS. ALL EXISTING CONTROL POINTS SHALL BE REMOVED AND REPLACED. SYSTEM SHALL BE CONTROLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). ALL SETPOINTS SHALL BE ADJUSTABLE. DURING HEATING MODE, THE HEATING CONTROL VALVES SHALL CONTINUE TO CONTROL WHEN THE FAN IS OFF FOR CONTINUED FREEZE PROTECTION. SETPOINTS SPACE COOLING TEMPERATURE SETPOINTS: OCCUPIED: 75 °F UNOCCUPIED: 81 °F SPACE HEATING TEMPERATURE SETPOINTS: OCCUPIED: 70 °F UNOCCUPIED: 64 °F SUPPLY AIRFLOW RATE: 5,200 CFM MIN / 14,000 CFM MAX RETURN AIRFLOW RATE: 4,900 CFM MIN / 13,700 CFM MAX MIN OUTSIDE AIRFLOW RATE: 950 CFM MIN / 2,100 CFM MAX RETURN CARBON DIOXIDE: 900 PPM DEHUMIDIFICATION SETPOINT: 60% RH FILTER DIFFERENTIAL PRESSURE HIGH LIMIT: 1.0" W.C. RETURN FAN STATIC PRESSURE SENSOR IS FOR MONITORING PURPOSES ONLY, TO ENSURE THE RELIEF AIR CHAMBER REMAINS POSITIVELY PRESSURIZED. ZONE OCCUPANCY SCHEDULE: 6 AM TO 11 PM, MON-SUN (COORDINATE WITH OWNER) SPACE OCCUPANCY ZONE OCCUPANCY SHALL BE DETERMINED BASED ON A TIME OF DAY SCHEDULE AND MANUAL OVERRIDE SWITCHES INTEGRAL TO THE SPACE TEMPERATURE SENSOR. IF THE SPACE BECOMES OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, AS DETERMINED BY THE TEMPERATURE SENSOR MANUAL OVERRIDE SWITCH; IN WHICH CASE THE SYSTEM SHALL OPERATE FOR UP TO 2 HOURS. ZONE TEMPERATURE & FAN SPEED CONTROL TEMPERATURE SETPOINTS SHALL BE DETERMINED BASED ON A PROGRAMMED SCHEDULE. OCCUPIED HEATING: IF THE ZONE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING TEMPERATURE SETPOINT, THE AIR HANDLING UNIT FAN SHALL INDEX TO MINIMUM POSITION, THE REHEAT COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. IF THE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING TEMPERATURE SETPOINT WITH THE REHEAT COIL CONTROL VALVE FULLY OPEN, THE BACS SHALL INDEX THE FAN COIL UNIT TO AUTOMATIC MODE, THE UNIT FAN SHALL START AND THE HEATING COIL CONTROL VALVE SHALL MODULATE AS NEEDED TO MAINTAIN SETPOINT. OCCUPIED COOLING: IF THE ZONE TEMPERATURE RISES ABOVE THE OCCUPIED COOLING TEMPERATURE SETPOINT, THE AIR HANDLING UNIT CHILLED WATER COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE DISCHARGE AIR TEMPERATURE OF 55°F. THE AIR HANDLING UNIT FAN SHALL MODULATE BETWEEN MINIMUM AND MAXIMUM POSITIONS AS NEEDED TO MAINTAIN THE SPACE TEMPERATURE AT SETPOINT. IF THE AIR HANDLING UNIT FAN IS AT MAXIMUM SETPOINT AND THE SPACE TEMPERATURE CONTINUES TO RISE ABOVE THE OCCUPIED COOLING TEMPERATURE SETPOINT, THE BACS SHALL INDEX THE FAN COIL TO AUTOMATIC MODE, THE UNIT FAN SHALL START AND THE COOLING COIL CONTROL VALVE SHALL MODULATE AS NEEDED TO MAINTAIN SETPOINT. UNOCCUPIED HEATING: IF THE TEMPERATURE FALLS BELOW THE UNOCCUPIED HEATING TEMPERATURE SETPOINT, THE BACS SHALL INDEX THE FAN COIL UNIT TO AUTOMATIC MODE, THE UNIT FAN SHALL START AND THE HEATING COIL CONTROL VALVE SHALL MODULATE AS NEEDED TO MAINTAIN SETPOINT. UNOCCUPIED COOLING: IF THE ZONE TEMPERATURE RISES ABOVE THE UNOCCUPIED COOLING TEMPERATURE SETPOINT, THE BACS SHALL INDEX THE FAN COIL TO AUTOMATIC MODE, THE UNIT FAN SHALL START AND THE COOLING COIL CONTROL VALVE SHALL MODULATE AS NEEDED TO MAINTAIN SETPOINT. UNDER NORMAL OPERATION, THE FAN COIL UNIT COOLING COIL CONTROL VALVE SHALL BE CLOSED WHENEVER THE HEATING COIL CONTROL VALVE IS OPEN. THE COOLING COIL CONTROL VALVES SHALL BE CLOSED WHEN THE SYSTEM FANS ARE OFF. TYPICAL ASD CONTROL / MONITORING POINTS ASDSS R SC M AOMBO BACnet / MSTP: - AV: POWER (KW) - AV: SPEED (RPM) R COM COMBO TEMP/RH/ CARBON DIOXIDE SENSOR AV SETPOINT(E)WIRE TO FIRE ALARM SYSTEM AO BI (E)OUTSIDE AIR CONDITIONSREFER TO PLANS T AI AI H co2 AI SAI AV SETPOINT AV SETPOINT AV DEWPOINTAI HT AI SF T AIAV SETPOINTAI F M ASD H C REHEAT COIL C C T AI FZ BI (E)AHU-3 N.O. E AO REHEAT COIL CONTROL VALVE N.C. E AO COOLING COIL CONTROL VALVE CWR CWS HWR HWS (E)TO FAN CIRCUIT MOD MOD AO AI F AO N.C. MINIMUM OUTSIDE AIR OUTSIDE AIR RA RETURN AIR MOD AO RA OA MA MOD AO EARELIEF AIR N.C. RA RF MONITORING POINT ONLY RETURN AIR T AI P (E)FILTER BANK COOLING COIL INDICATES EXISTING AI F NEW FAN INLET AIRFLOW STATION AISP AI AV SETPOINT N.O. T AI RA SD BI (E)RAF-3 AOM (E)WIRE TO FIRE ALARM SYSTEM SUPPLY AIRSA NEW FAN INLET AIRFLOW STATION SEQUENCE OF OPERATION START/STOP DURING THE SCHEDULED OCCUPANCY PERIOD, THE SYSTEM SHALL START BASED ON A TIME OF DAY SCHEDULE AND AN OPTIMUM START CONTROL ALGORITHM. THE ALGORITHM SHALL, AS A MINIMUM, BE A FUNCTION OF THE DIFFERENCE BETWEEN SPACE TEMPERATURE AND THE OCCUPIED SETPOINT AND THE AMOUNT OF TIME PRIOR TO THE SCHEDULED OCCUPANCY. THE SYSTEM SHALL BE OFF WHEN THE SPACE IS IN UNOCCUPIED MODE, UNLESS THE SYSTEM IS NEEDED TO MAINTAIN THE OCCUPIED SETBACK OR UNOCCUPIED TEMPERATURE SETPOINTS. VENTILATION DAMPER CONTROL WHEN THE SPACE IS UNOCCUPIED, THE MINIMUM OUTSIDE AIR DAMPER, OUTSIDE AIR DAMPER AND RELIEF AIR DAMPER SHALL BE CLOSED, THE RETURN AIR DAMPER SHALL BE OPEN. WHEN THE SPACE IS OCCUPIED THE MINIMUM OUTSIDE AIR DAMPER SHALL OPEN TO MINIMUM POSITION AND THEN MODULATE AS NEEDED TO MAINTAIN THE CARBON DIOXIDE LEVEL AT SETPOINT. WHEN THE MINIMUM OUTSIDE AIR DAMPER IS FULLY OPEN AND THE VENTILATION AIRFLOW IS BELOW SETPOINT, THE RETURN AIR DAMPER SHALL MODULATE CLOSED AS NEEDED TO MAINTAIN SETPOINT. WHEN THE RETURN AIR DAMPER IS FULLY OPEN AND THE VENTILATION AIRFLOW IS ABOVE SETPOINT, THE MINIMUM OUTSIDE AIR DAMPER SHALL MODULATE CLOSED AS NEEDED TO MAINTAIN SETPOINT. RETURN FAN CONTROL THE RETURN AIR FAN SHALL MODULATE AS NEEDED TO MATCH THE SUPPLY AIRFLOW MINUS 300 CFM. ECONOMIZER CONTROL THE SYSTEM SHALL BE EQUIPED WITH BOTH MODULATED AND DIFFERENTIAL DRY BULB INTEGRATED ECONOMIZER CONTROL SEQUENCES. MODULATED ECONOMIZER MODE (MAT CONTROL): WHEN THE RETURN AIR TEMPERATURE RISES ABOVE THE COOLING SETPOINT, AND THE OUTSIDE AIR TEMPERATURE IS LESS THAN 55°F, MODULATED ECONOMIZER MODE (MAT CONTROL) SHALL BE INITITATED. THE OUTSIDE AIR DAMPER, RETURN AND RELIEF AIR DAMPERS SHALL MODULATE TO MAINTAIN THE MIXED AIR TEMPERATURE SETPOINT OF 55°F. LOW LIMIT: WHEN THE MIXED AIR TEMPERATURE FALLS BELOW SETPOINT, THE OUTSIDE AIR, RELIEF AIR DAMPER SHALL MODULATE TO MINIMUM POSITION AND THE RETURN AIR DAMPER SHALL INDEX TO MAXIMUM AND THE SYSTEM HEATING MODE SHALL BE INITITATED. HIGH LIMIT: WHEN THE MIXED AIR TEMPERATURE RISES ABOVE SETPOINT, THE OUTSIDE AIR AND RELIEF AIR DAMPERS SHALL INDEX TO FULL OPEN, THE RETURN AIR DAMPER SHALL CLOSE AND INTEGRATED EONOMIZER MODE SHALL BE INITITATED. INTEGRATED ECONOMIZER MODE: WHEN THE RETURN AIR TEMPERATURE IS ABOVE THE OUTDOOR AIR TEMPERATURE AND THE OUTDOOR AIR DEWPOINT TEMPERATURE IS BELOW 60°F, INTEGRATED ECONOMIZER MODE SHALL BE INITITATED. THE OUTSIDE AND RELIEF DAMPERS SHALL OPEN AND THE RETURN AIR DAMPER SHALL BE CLOSED, THE CHILLED WATER CONTROL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SETPOINT. LOW LIMIT SHUTOFF: INTEGRATED ECONOMIZER CONTROL SHALL BE DISABLED AND MODULATED ECONOMIZER SHALL BE INITITIATED WHEN THE OUTSIDE AIR TEMPERATURE FALLS BELOW 55°F. HIGH LIMIT SHUTOFF: INTEGRATED ECONOMIZER CONTROL SHALL BE DISABLED WHEN THE OUTDOOR AIR TEMPERATURE EXCEEDS THE RETURN AIR TEMPERATURE. THE OUTSIDE AIR, RELIEF AIR AND RETURN AIR DAMPERS SHALL INDEX TO CO2 CONTROL AND COOLING MODE SHALL BE INITITIATED. DEHUMIDIFICATION CONTROL WHEN THE SPACE HUMIDITY EXCEEDS SETPOINT, AS SENSED BY THE SPACE HUMIDITY SENSOR, DEHUMIDIFCATION CONTROL SHALL BE ENABLED. THE CHILLED WATER CONTROL VALVE SHALL MODULATE OPEN AS REQUIRED TO MAINTAIN THE SPACE HUMIDITY SETPOINT. IF THE SPACE TEMPERATURE DROPS BELOW THE SPACE TEMPERATURE SETPOINT, THE REHEAT COIL CONTROL VAVLE SHALL MODULATE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE SETPOINT. SAFETIES FREEZE PROTECTION: THE SUPPLY AND RETURN AIR FANS SHALL SHUT DOWN, THE OUTSIDE AIR AND EXHAUST AIR DAMPERS SHALL CLOSE, AND THE CONTROL VALVES SHALL OPEN UPON ACTIVATION OF THE LOW LIMIT TEMPERATURE SWITCH. M ASD SD BI AOM (E)WIRE TO FIRE ALARM SYSTEM OA N.C. SA D F OV POINT SCHEDULE EXISTING AIR HANDLING UNIT AHU-3 HARDWARE POINTS SOFTWARE POINTS SHOWN ON GRAPHIC NOTESBIBOAIAOAV BV SCH TREND ALARM BACS EMCS DESCRIPTION STEAM LOAD SHED X (6)BINARY NETWORK INPUTS FROM EMCS CHILLED WATER LOAD SHED X (4)BINARY NETWORK INPUTS FROM EMCS OUTSIDE AIR TEMPERATURE X X X IF NOT PROVIDED GLOBALLY OUTSIDE AIR RELATIVE HUMIDITY X X IF NOT PROVIDED GLOBALLY OUTSIDE AIR DEWPOINT X X X IF NOT PROVIDED GLOBALLY OUTSIDE AIR DAMPER POSITION COMMAND X X MINIMUM OUTSIDE AIR DAMPER POSITION COMMAND X X MINIMUM OUTSIDE AIR FLOW X X X RETURN AIR DAMPER POSITION COMMAND X X RETURN FAN DISCHARGE AIR STATIC PRESSURE X X X MONITORING POINT ONLY RELIEF AIR DAMPER POSITION COMMAND X X FILTER DIFFERENTIAL PRESSURE X X X X HIGH LIMIT X MIXED AIR TEMPERATURE X X X AVERAGING SENSOR MIXED AIR TEMPERATURE SETPOINT X X X LOW LIMIT TEMPERATURE STATUS X X X LOW LIMIT X COOLING COIL VALVE POSITION COMMAND X X X X 5o DELTA T ACROSS COIL WITH VALVE COMMANDED CLOSED X COOLING COIL DISCHARGE AIR TEMPERATURE X X X X + / - 4 DEG F FROM SETPOINT X AVERAGING SENSOR REHEAT COIL VALVE POSITION COMMAND X X X X 5o DELTA T ACROSS COIL WITH VALVE COMMANDED CLOSED X SUPPLY FAN MOTOR START/STOP X X X X INTERLOCK WITH FA SYSTEM SUPPLY FAN SPEED COMMAND X X X SUPPLY FAN STATUS X X X FAILURE X VIA CONTACT ON DRIVE SUPPLY FAN POWER (kW)X X X BACnet MSTP NETWORK POINT SUPPLY FAN SPEED (RPM)X X X BACnet MSTP NETWORK POINT SUPPLY FAN AIRFLOW X X X INSTALL IN INLET CONE AHU DISCHARGE AIR TEMPERATURE X X X X + / - 4 DEG F FROM SETPOINT X AHU DISCHARGE AIR TEMPERATURE SETPOINT X X X SUPPLY DUCT SMOKE DETECTOR STATUS X X RETURN DUCT SMOKE DETECTOR STATUS X X RETURN AIR TEMPERATURE X X X RETURN FAN MOTOR START/STOP X X X X INTERLOCK WITH FA SYSTEM RETURN FAN SPEED COMMAND X X X RETURN FAN STATUS X X X FAILURE X VIA CONTACT ON DRIVE RETURN FAN POWER (kW)X X X BACnet MSTP NETWORK POINT RETURN FAN SPEED (RPM)X X X BACnet MSTP NETWORK POINT RETURN FAN AIRFLOW X X X INSTALL IN INLET CONE ZONE TEMPERATURE SETPOINT X X X ZONE TEMPERATURE X X X +/- 4 DEG F FROM SETPOINT X REFER TO PLANS ZONE RELATIVE HUMIDITY X X X REFER TO PLANS ZONE RELATIVE HUMIDITY SETPOINT X X X ZONE CARBON DIOXIDE SETPOINT X X X ZONE CARBON DIOXIDE X X X +/- 4 DEG F FROM SETPOINT X REFER TO PLANS ZONE OCCUPANCY X X X REFER TO PLANS FCU HEATING COIL CONTROL VALVE POSITION COMMAND X X X FAIL LAST FCU COOLING COIL CONTROL VALVE POSITION COMMAND X X X NORMALLY CLOSED FAN MOTOR START/STOP X X X FAN STATUS X X X FAILURE X VIA CURRENT SENSOR FCU LEAVING AIR TEMPERATURE X X X SINGLE POINT SENSOR COOLING COIL N.C. C C H CFANFAN HEATING COIL E E AO AI F.L. CS M BI SS BO SARA MS T AI REFER TO PLANS NOTE: THIS TEMPERATURE CONTROL DRAWING IS SUITABLE FOR BOTH FLOOR MOUNTED AND CEILING MOUNTED FOUR PIPE FAN COIL UNITS. COOLING COIL N.C. C C H CFANFAN HEATING COIL E E AO AI F.L. CS M BI SS BO INDICATES EXISTING SA D T AI AI H AV SETPOINT REFER TO PLANS COMBO TEMP/RH SENSOR SARA F REFER TO PLANS OCCUPANCY SENSOR (ONLY WHERE INDICATED ON PLANS) OS BI MS T AI POINT SCHEDULE FAN COIL UNIT HARDWARE POINTS SOFTWARE POINTS SHOWN ON GRAPHIC NOTESBIBOAIAOAV BV SCH TREND ALARM BACS EMCS DESCRIPTION STEAM LOAD SHED X (6)BINARY NETWORK INPUTS FROM EMCS CHILLED WATER LOAD SHED X (4)BINARY NETWORK INPUTS FROM EMCS HEATING COIL CONTROL VALVE POSITION COMMAND X X X FAIL LAST COOLING COIL CONTROL VALVE POSITION COMMAND X X X NORMALLY CLOSED ZONE TEMPERATURE SETPOINT X X X ZONE TEMPERATURE X X X +/- 4 DEG F FROM SETPOINT X REFER TO PLANS ZONE RELATIVE HUMIDITY X X X MONITORING POINT ONLY ZONE RELATIVE HUMIDITY SETPOINT X X X ZONE OCCUPANCY X X X REFER TO PLANS FAN MOTOR START/STOP X X X FAN STATUS X X X FAILURE X VIA CURRENT SENSOR FCU LEAVING AIR TEMPERATURE X X X SINGLE POINT SENSOR SYSTEM DESCRIPTION FOUR PIPE FAN COIL UNIT GENERAL EXISTING ZONE SHALL BE PROVIDED WITH NEW CONTROL POINTS. ALL EXISTING CONTROL POINTS SHALL BE REMOVED AND REPLACED. SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). ALL SETPOINTS SHALL BE ADJUSTABLE. SETPOINTS SPACE COOLING TEMPERATURE SETPOINTS: OCCUPIED: 75 0F OCCUPIED SETBACK: 78 0F UNOCCUPIED: 81 0F SPACE HEATING TEMPERATURE SETPOINTS: OCCUPIED: 70 0F OCCUPIED SETBACK: 67 0F UNOCCUPIED: 640F MINIMUM SPACE OCCUPANCY INDEX TIME: 30 MINUTES ZONE OCCUPANCY SCHEDULE: COORDINATE WITH OWNER ZONE OCCUPANCY OCCUPANCY SHALL BE DETERMINED BASED ON A COMBINATION OF A TIME OF DAY SCHEDULE AND A SPACE OCCUPANCY SENSOR. DURING THE SCHEDULED OCCUPANCY PERIOD, THE ZONE SHALL BE INITIALLY INDEXED TO OCCUPIED AND OPERATE FOR A MINIMUM OF 30 MINUTES, AT WHICH TIME THE SPACE OCCUPANCY SENSOR SHALL INDEX THE SPACE BETWEEN OCCUPIED AND OCCUPIED SETBACK MODE. IF THE SPACE BECOMES OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, AS DETERMINED VIA THE OCCUPANCY SENSOR, THE ZONE SHALL BE INDEXED TO OCCUPIED FOR THE DURATION OF OCCUPANCY. THE ZONE SHALL INDEX BACK TO UNOCCUPIED WHEN OCCUPANCY IS NOT SENSED FOR A PERIOD OF 30 MINUTES. FOR ZONES WITH MULTIPLE SPACES, AN OCCUPANCY SENSOR SHALL BE PROVIDED IN EACH SPACE, AND ZONE OCCUPANCY SHALL BE BASED ON OCCUPANCY INPUTS FROM ANY OF THE SPACE OCCUPANCY SENSORS ASSOCIATED WITH THAT ZONE. FAN COIL START/STOP THE FAN COIL UNIT SHALL OPERATE WHENEVER THE SPACE IS IN OCCUPIED OR OCCUPIED SETBACK MODE. SEQUENCE OF OPERATION FAN SPEED CONTROL THE FAN SPEED SHALL BE SELECTED VIA THE NEW COMBINATION TEMPERATURE SENSOR FAN SPEED CONTROL. ZONE TEMPERATURE CONTROL TEMPERATURE SETPOINTS SHALL BE DETERMINED BASED ON A COMBINATION OF PROGRAMMED SCHEDULE AND ZONE OCCUPANCY. OCCUPIED HEATING: IF THE ZONE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD AND THE ZONE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING TEMPERATURE SETPOINT, THE FAN SHALL BE INDEXED TO START AND THE HEATING COIL CONTROL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN SETPOINT. THE COOLING COIL CONTROL VALVE SHALL BE CLOSED. OCCUPIED COOLING: IF THE ZONE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD AND THE ZONE TEMPERATURE RISES ABOVE THE OCCUPIED COOLING TEMPERATURE SETPOINT, THE FAN COIL UNIT SHALL BE INDEXED TO START AND THE COOLING COIL CONTROL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN SETPOINT. THE HEATING COIL CONTROL VALVE SHALL BE CLOSED. OCCUPIED SETBACK: IF THE ZONE IS UNOCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, THE ABOVE OCCUPIED HEATING/COOLING SEQUENCES SHALL APPLY. THE SPACE SHALL BE MAINTAINED AT THE OCCUPIED SETBACK TEMPERATURE SETPOINTS. UNOCCUPIED HEATING: IF THE ZONE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, AND THE ZONE TEMPERATURE FALLS BELOW THE UNOCCUPIED HEATING TEMPERATURE SETPOINT, THE FAN COIL UNIT SHALL BE INDEXED TO START AND THE HEATING COIL CONTROL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN SETPOINT. THE COOLING COIL CONTROL VALVE SHALL BE CLOSED. UNOCCUPIED COOLING: IF THE ZONE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, AND THE ZONE TEMPERATURE RISES ABOVE THE UNOCCUPIED COOLING TEMPERATURE SETPOINT, THE FAN COIL UNIT SHALL BE INDEXED TO START AND THE COOLING COIL CONTROL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN SETPOINT. THE HEATING COIL CONTROL VALVE SHALL BE CLOSED. IF THE SPACE BECOMES OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX TO OCCUPIED FOR THE DURATION OF OCCUPANCY. WHEN THE SPACE BECOMES UNOCCUPIED AGAIN DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL INDEX BACK TO UNOCCUPIED MODE. ZONES WITHOUT OCCUPANCY SENSORS: SEQUENCE SHALL NOT INCLUDE OCCUPIED SETBACK AND OCCUPANCY SHALL BE DETERMINED BASED UPON A TIME OF DAY SCHEDULE. OV REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 CONTROL SCHEMATIC & SYSTEM SUMMARY H-502B 190306 RFG RFG 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor HallNTS 1 EXISTING AIR HANDLING UNIT AHU-3 & EXISTING RETURN AIR FAN RAF-3 CONTROL SCHEMATIC AND SYSTEM SUMMARY NTS 2 FOUR PIPE FAN COIL UNIT CONTROL SCHEMATIC & SYSTEM SUMMARY AHU-4 SYSTEM DESCRIPTION EXISTING 100% OUTSIDE AIR HANDLING UNIT (AHU-4) EXISITNG EXHAUST AIR FAN (EF-1) (EXISTING CONTROL POINTS ARE SHOWN DASHED AND NEW CONTROL POINTS ARE SHOWN SOLID ON THE CONTROL DIAGRAM) GENERAL EXISTING SYSTEM SHALL BE PROVIDED WITH NEW CONTROL POINTS. ALL EXISTING CONTROL POINTS SHALL BE REMOVED AND REPLACED. SYSTEM SHALL BE CONTROLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). ALL SETPOINTS SHALL BE ADJUSTABLE. DURING HEATING MODE, THE HEATING CONTROL VALVES SHALL CONTINUE TO CONTROL WHEN THE FAN IS OFF FOR CONTINUED FREEZE PROTECTION. SETPOINTS AHU DISCHARGE AIR TEMPERATURE: SEE RESET SCHEDULE HR DISCHARGE AIR TEMPERATURE: SAME AS AHU DAT SETPOINT DEHUMIDIFICATION SETPOINT: 60% RH FREEZESTAT LOW LIMIT TEMPERATURE: 380F SUPPLY AIRFLOW RATE: 3,470 CFM EXHAUST AIRFLOW RATE = SUPPLY AIR FAN AIRFLOW RATE OF AHU-4 (3,740 CFM) + THE SUPPLY AIRFLOW RATE OF AHU-5 (3,600 CFM / 1,100 CFM) + 1480 CFM FROM AHU-2 + 590 CFM FROM HUGHES HALL AHU. FILTER DIFFERENTIAL PRESSURE HIGH LIMIT: 1.0" W.C. ZONE OCCUPANCY SCHEDULE: 6 AM TO 9 PM - MON-FRI, 8 AM TO 7:00 PM SAT- SUN (COORDINATE WITH OWNER) FAN START/STOP AIR HANDLING UNIT SUPPLY FAN SHALL BE INTERLOCKED WITH THE ASSOCIATED HEAT RECOVERY EXHAUST FAN EF-1. HEAT RECOVERY EXHAUST FAN EF-1 SHALL BE INTERLOCKED WITH AHU-2, AHU-4 AND AHU-5. OCCUPIED: THE SUPPLY AIR FAN SHALL START AND OPERATE CONTINUOUSLY BASED ON A TIME OF DAY SCHEDULE. THE EXHAUST AIR FAN AND SHALL START WHEN ANY OF THE AHU'S, ASSOCIATED WITH THE EXHAUST FAN, ARE INDEXED TO START. UNOCCUPIED: THE SUPPLY AIR FAN SHALL BE OFF WHEN THE SYSTEM IS IN UNOCCUPIED MODE. THE EXHAUST AIR FAN SHALL BE OFF AND SHALL BE INDEXED TO START WHEN ANY OF THE AHU'S, ASSOCIATED WITH THE EXHAUST FAN, ARE INDEXED TO START. SHUTOFF DAMPER CONTROL WHEN THE SYSTEM FANS ARE OFF, THE ASSOCAITED OUTSIDE AIR AND EXHAUST AIR DAMPERS SHALL BE CLOSED. WHEN THE SYSTEM FANS ARE INDEXED TO START, THE ASSOCIATED OUTSIDE AIR AND EXHAUST AIR DAMPERS SHALL PROVE OPEN, VIA END SWITCH, PRIOR TO STARTING THE SYSTEM FANS. TYPICAL ASD CONTROL / MONITORING POINTS ASDSS R SC M AOMBO BACnet / MSTP: - AV: POWER (KW) - AV: SPEED (RPM) R COM (E)WIRE TO FIRE ALARM SYSTEM AO BI (E)OUTSIDE AIR CONDITIONS AV DEWPOINTAI HT AI SF T AIAV SETPOINTAI F M ASD C C COOLING COIL PH C T AI FZ BI (E)AHU-4 N.C. E AO COOLING COIL CONTROL VALVE N.O. E AO PREHEAT COIL CONTROL VALVE GR GS CWR CWS (E)TO FAN CIRCUIT MOD AO OUTSIDE AIR OA EF AI P (E)FILTER BANK GYLCOL PREHEAT COIL INDICATES EXISTING NEW FAN INLET AIRFLOW STATION EA (E)EF-1 SUPPLY AIRSA NEW FAN INLET AIRFLOW STATION SEQUENCE OF OPERATION M ASD SD BI AOM (E)WIRE TO FIRE ALARM SYSTEM H C REHEAT COIL N.O. E AO REHEAT COIL CONTROL VALVE HWR HWS T AI (E)Q-DOT HEAT RECOVERYT AI AI F AI P (E)FILTER BANK EXHAUST AIR FROM AHU-5 ZONES EXHAUST AIR FROM AHU-4 ZONES AI H EXHAUST AIR MOD AO N.C. N.C. T AI EA EA EA T AI FILTER STATUS THE DDC CONTROL SYSTEM SHALL MONITOR THE DIFFERENTIAL PRESSURE ACROSS THE SYSTEM FILTER BANKS. AIRFLOW MONITORING THE DDC CONTROL SYSTEM SHALL MONITOR THE SUPPLY AIRFLOW AND EXHAUST AIRFLOW RATES AS MEASURED BY THEIR RESPECTIVE AIRFLOW MEASURING STATIONS. FAN SPEED CONTROL THE SUPPLY AIR FAN SHALL MODULATE VIA VARIABLE FREQUENCY DRIVE AS REQUIRED TO MAINTAIN THE SUPPLY FAN AIRFLOW SETPOINT. THE EXHAUST AIR FAN SHALL MODULATE VIA VARIABLE FREQUENCY DRIVE AS REQUIRED TO MAINTAIN THE EXHAUST FAN AIRFLOW SETPOINT. SUPPLY AIR TEMPERATURE CONTROL DISCHARGE AIR TEMPERATURE RESET: THE DISCHARGE AIR TEMPERATURE SHALL BE ALLOWED TO RESET BASED ON THE FOLLOWING SCHEDULE: OAT = 75°F & ABOVE --- DAT = 55°F OAT = 55°F & BELOW --- DAT = 65°F WHEN DISCHARGE AIR TEMPERATURE DROPS BELOW SETPOINT, THE CHILLED WATER CONTROL VALVE SHALL BE CLOSED, AND THE PREHEAT COIL CONTROL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SETPOINT. WHEN DISCHARGE AIR TEMPERATURE RISES ABOVE SETPOINT, THE PREHEAT COIL CONTROL VALVE SHALL BE CLOSED, AND THE CHILLED WATER CONTROL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SETPOINT. HUMIDITY CONTROL WHEN THE EXHAUST AIR HUMIDITY EXCEEDS 60% RH AS SENSED BY THE EXHAUST AIR RELATIVE HUMIDITY SENSOR, DEHUMIDIFICATION CONTROL SHALL BE ENABLED. THE CHILLED WATER CONTROL VALVE SHALL MODULATE OPEN AS REQUIRED TO MAINTAIN THE EXHAUST AIR HUMIDITY SETPOINT AND THE REHEAT COIL CONTROL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN THE AHU DISCHARGE AIR TEMPERATURE SETPOINT. SAFETIES FREEZE PROTECTION: THE SUPPLY AIR FAN SHALL SHUT DOWN, THE OUTSIDE AIR DAMPER SHALL CLOSE AND THE CONTROL VALVES SHALL OPEN UPON ACTIVATION OF THE LOW LIMIT TEMPERATURE SWITCH. EA EXHAUST AIR FROM AHU-2 ZONES POINT SCHEDULE EXISTING AIR HANDLING UNIT AHU-4 HARDWARE POINTS SOFTWARE POINTS SHOWN ON GRAPHIC NOTESBIBOAIAOAV BV SCH TREND ALARM BACS EMCS DESCRIPTION STEAM LOAD SHED X (6)BINARY NETWORK INPUTS FROM EMCS CHILLED WATER LOAD SHED X (4)BINARY NETWORK INPUTS FROM EMCS OUTSIDE AIR TEMPERATURE X X X IF NOT PROVIDED GLOBALLY OUTSIDE AIR RELATIVE HUMIDITY X X IF NOT PROVIDED GLOBALLY OUTSIDE AIR DEWPOINT X X X IF NOT PROVIDED GLOBALLY OUTSIDE AIR DAMPER POSITION COMMAND X X OUTSIDE AIR FILTER RACK DIFFERENTIAL PRESSURE X X X X HIGH LIMIT X HP HEAT RECOVERY SUPPLY LEAVING AIR TEMPERATURE X X X PREHEAT COIL VALVE POSITION COMMAND X X X X 5o DELTA T ACROSS COIL WITH VALVE COMMANDED CLOSED X PREHEAT COIL DISCHARGE AIR TEMPERATURE X X X X + / - 4 DEG F FROM SETPOINT X AVERAGING SENSOR LOW LIMIT TEMPERATURE STATUS X X X LOW LIMIT X COOLING COIL VALVE POSITION COMMAND X X X X 5o DELTA T ACROSS COIL WITH VALVE COMMANDED CLOSED X COOLING COIL DISCHARGE AIR TEMPERATURE X X X X + / - 4 DEG F FROM SETPOINT X AVERAGING SENSOR REHEAT COIL VALVE POSITION COMMAND X X X X 5o DELTA T ACROSS COIL WITH VALVE COMMANDED CLOSED X SUPPLY FAN MOTOR START/STOP X X X X INTERLOCK WITH FA SYSTEM SUPPLY FAN SPEED COMMAND X X X SUPPLY FAN STATUS X X X FAILURE X VIA CONTACT ON DRIVE SUPPLY FAN POWER (kW)X X X BACnet MSTP NETWORK POINT SUPPLY FAN SPEED (RPM)X X X BACnet MSTP NETWORK POINT SUPPLY FAN AIRFLOW X X X INSTALL IN INLET CONE AHU DISCHARGE AIR TEMPERATURE X X X X + / - 4 DEG F FROM SETPOINT X AHU DISCHARGE AIR TEMPERATURE SETPOINT X X X SUPPLY DUCT SMOKE DETECTOR STATUS X X EXHAUST AIR FILTER RACK DIFFERENTIAL PRESSURE X X X X HIGH LIMIT X EXHAUST AIR RELATIVE HUMIDITY X X X HP HEAT RECOVERY EXHAUST ENTERING AIR TEMPERATURE X X X HP HEAT RECOVERY EXHAUST LEAVING AIR TEMPERATURE X X X EXHAUST FAN MOTOR START/STOP X X X X INTERLOCK WITH FA SYSTEM EXHAUST FAN SPEED COMMAND X X X EXHAUST FAN STATUS X X X FAILURE X VIA CONTACT ON DRIVE EXHAUST FAN POWER (kW)X X X BACnet MSTP NETWORK POINT EXHAUST FAN SPEED (RPM)X X X BACnet MSTP NETWORK POINT EXHAUST FAN AIRFLOW X X X INSTALL IN INLET CONE EXHAUST AIR DAMPER POSITION COMMAND X X HEAT PIPE HEAT RECOVERY EFFECTIVENESS X X X CALCULATED BASED ON TEMPERATURE HEAT PIPE HEAT RECOVERY RECOVERED ENERGY (BTUH)X X X CALCULATED BASED ON TEMPERATURE HEAT PIPE HEAT RECOVERY TOTALIZED RECOVERED ENERGY (BTU/YR)X X X CALCULATED BASED ON TEMPERATURE SYSTEM DESCRIPTION EXISTING 100% OUTSIDE AIR HANDLING UNIT (AHU-5) (EXISTING CONTROL POINTS ARE SHOWN DASHED AND NEW CONTROL POINTS ARE SHOWN SOLID ON THE CONTROL DIAGRAM) GENERAL EXISTING SYSTEM SHALL BE PROVIDED WITH NEW CONTROL POINTS. ALL EXISTING CONTROL POINTS SHALL BE REMOVED AND REPLACED. SYSTEM SHALL BE CONTROLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). ALL SETPOINTS SHALL BE ADJUSTABLE. DURING HEATING MODE, THE HEATING CONTROL VALVES SHALL CONTINUE TO CONTROL WHEN THE FAN IS OFF FOR CONTINUED FREEZE PROTECTION. SETPOINTS SPACE COOLING TEMPERATURE SETPOINTS: OCCUPIED: 75 °F UNOCCUPIED: 81 °F SPACE HEATING TEMPERATURE SETPOINTS: OCCUPIED: 70 °F UNOCCUPIED: 64 °F FREEZESTAT LOW LIMIT TEMPERATURE: 380F SUPPLY AIRFLOW RATE: 1,100 CFM MIN / 3,600 CFM MAX SPACE CARBON DIOXIDE: 900 PPM FILTER DIFFERENTIAL PRESSURE HIGH LIMIT: 1.0" W.C. ZONE OCCUPANCY SCHEDULE: 6 AM TO 9 PM - MON-FRI, 8 AM TO 7:00 PM SAT- SUN (COORDINATE WITH OWNER) START/STOP AIR HANDLING UNIT SUPPLY FAN SHALL BE INTERLOCKED WITH THE ASSOCIATED HEAT RECOVERY EXHAUST FAN EF-1. EF-1 SHALL BE INTERLOCKED WITH AHU-2, AHU-4 AND AHU-5. (REFER TO AHU-4 CONTROL SCHEMATIC AND SYSTEM SUMMARY FOR EXHAUST FAN OPERATION) OCCUPIED: SUPPLY AIR FAN SHALL START AND OPERATE CONTINUOUSLY BASED ON A TIME OF DAY SCHEDULE. UNOCCUPIED: DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SYSTEM SHALL BE INDEXED TO START WHENEVER ANY SPACE ASSOCIATED WITH THE SYSTEM IS OCCUPIED, AS DETERMINED VIA SPACE OCCUPANCY/VACCANCY SENSOR. THE SYSTEM SHALL STOP AND INDEX BACK TO UNOCCUPIED MODE WHEN OCCUPANCY IS NOT SENSED FOR A PERIOD OF 30 MINUTES. IF OVERRIDE SWITCHES ARE PROVIDED IN LIEU OF OCCUPANCY SENSORS, THE SYSTEM SHALL BE INDEXED TO START WHENEVER ANY OF THE MANUAL OVERRIDE SWITCHES INDICATE OCCUPANCY; IN WHICH CASE THE SYSTEM SHALL OPERATE FOR UP TO 2 HOURS. SEQUENCE OF OPERATION TYPICAL ASD CONTROL / MONITORING POINTS ASDSS R SC M AOMBO BACnet / MSTP: - AV: POWER (KW) - AV: SPEED (RPM) R COM (E)WIRE TO FIRE ALARM SYSTEM AO BI (E)OUTSIDE AIR CONDITIONS AV DEWPOINTAI HT AI SF T AIAV SETPOINT M ASD C C COOLING COIL PH C T AI FZ BI (E)AHU-4 N.C. E AO COOLING COIL CONTROL VALVE N.O. E AO PREHEAT COIL CONTROL VALVE GR GS CWR CWS (E)TO FAN CIRCUIT MOD AO OUTSIDE AIR OA AI P (E)FILTER BANK GYLCOL PREHEAT COIL INDICATES EXISTING EA SUPPLY AIRSA SD BI AOM (E)WIRE TO FIRE ALARM SYSTEM EXHAUST AIR FROM AHU-5 ZONES N.C. TO (E)EF-1 SHUTOFF DAMPER CONTROL WHEN THE SYSTEM SUPPLY FAN IS OFF, THE OUTSIDE AIR DAMPER SHALL BE CLOSED. WHEN THE SYSTEM SUPPLY FAN IS INDEXED TO START, THE OUTSIDE AIR DAMPER SHALL PROVE OPEN, VIA END SWITCH, PRIOR TO STARTING THE SYSTEM FAN. FILTER STATUS THE DDC CONTROL SYSTEM SHALL MONITOR THE DIFFERENTIAL PRESSURE ACROSS THE SYSTEM FILTER BANKS. FAN SPEED/VENTILATION CONTROL WHEN THE ZONES ARE OCCUPIED, THE SUPPLY AIR FAN SHALL MODULATE BETWEEN MINIMUM AND MAXIMUM SPEED, VIA VARIABLE FREQUENCY DRIVE, AS REQUIRED TO MAINTAIN THE SPACE CARBON DIOXIDE LEVELS AT SETPOINT. THE EXHAUST AIR FAN SHALL TRACK THE SUPPLY AIR FAN AS NEEDED TO MAINTAIN PROPER PRESSURIZATION. SUPPLY AIR TEMPERATURE CONTROL TEMPERATURE SETPOINTS SHALL BE DETERMINED BASED ON A COMBINATION OF PROGRAMMED SCHEDULE AND SPACE OCCUPANCE SENSOR. THE AIR HANDLING UNIT DISCHARGE AIR TEMPERATURE WILL BE DETERMINED UPON THE TEMPERATURE SETPOINT OF THE LOUNGE. THE CLASSROOM TEMPERATURE SETPOINTS WILL OPERATE INDEPENDANTLY/INDIVIDUALLY AND BE CONDITIONED BY THEIR RESPECTIVE FAN COIL UNITS. OCCUPIED HEATING: IF THE LOUNGE ZONE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING TEMPERATURE SETPOINT, THE REHEAT COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. IF THE LOUNGE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING TEMPERATURE SETPOINT, WITH THE REHEAT COIL CONTROL VALVE FULLY OPEN, THEN THE LOUNGE FIN TUBE RADIATION CONTROL VALVE SHALL MODULATE AS NEEDED TO MAINTAIN THE LOUNGE TEMPERATURE SETPOINT. OCCUPIED COOLING: IF THE LOUNGE ZONE TEMPERATURE RISES ABOVE THE OCCUPIED COOLING TEMPERATURE SETPOINT, THE AIR HANDLING UNIT FAN SHALL MODULATE TO MAXIMUM SPEED AND THE CHILLED WATER COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE SPACE TEMPERATURE SETPOINT. UNOCCUPIED HEATING: IF THE ZONE TEMPERATURE FALLS BELOW THE UNOCCUPIED HEATING TEMPERATURE SETPOINT, THE UNIT FAN SHALL START AND RUN AT MINIMUM SPEED AND THE UNIT REHEAT COIL CONTROL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN SETPOINT. IF THE SPACE TEMPERATURE SETPOINT IS STILL NOT MET AND THE REHEAT CONTROL VALVE IS FULLY OPEN, THEN THE FIN TUBE RADIATION CONTROL VALVE SHALL MODULATE TO MAINTAIN THE LOUNGE SPACE TEMPERATURE SETPOINT. UNOCCUPIED COOLING: IF THE ZONE TEMPERATURE RISES ABOVE THE UNOCCUPIED COOLING TEMPERATURE SETPOINT, THE UNIT FAN SHALL START AND RUN AT MAXIMUM SPEED AND THE CHILLED WATER COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN THE LOUNGE SPACE TEMPERATURE AT SETPOINT. SAFETIES FREEZE PROTECTION: THE SUPPLY AND EXHAUST AIR FANS SHALL SHUT DOWN, THE OUTSIDE AIR AND EXHAUST AIR DAMPERS SHALL CLOSE AND THE CONTROL VALVES SHALL OPEN UPON ACTIVATION OF THE LOW LIMIT TEMPERATURE SWITCH. HWR F.L. E FTR CONTROL VALVE AO HWS REFER TO PLANS COMBO TEMP/RH/ CARBON DIOXIDE SENSOR AV SETPOINT REFER TO PLANS T AI AI H co2 AI SAI AV SETPOINT AV SETPOINT SA D F OV POINT SCHEDULE EXISTING AIR HANDLING UNIT AHU-5 HARDWARE POINTS SOFTWARE POINTS SHOWN ON GRAPHIC NOTESBIBOAIAOAV BV SCH TREND ALARM BACS EMCS DESCRIPTION STEAM LOAD SHED X (6)BINARY NETWORK INPUTS FROM EMCS CHILLED WATER LOAD SHED X (4)BINARY NETWORK INPUTS FROM EMCS OUTSIDE AIR TEMPERATURE X X X IF NOT PROVIDED GLOBALLY OUTSIDE AIR RELATIVE HUMIDITY X X IF NOT PROVIDED GLOBALLY OUTSIDE AIR DEWPOINT X X X IF NOT PROVIDED GLOBALLY OUTSIDE AIR DAMPER POSITION COMMAND X X FILTER DIFFERENTIAL PRESSURE X X X X HIGH LIMIT X PREHEAT COIL VALVE POSITION COMMAND X X X X 5o DELTA T ACROSS COIL WITH VALVE COMMANDED CLOSED X PREHEAT COIL DISCHARGE AIR TEMPERATURE X X X X + / - 4 DEG F FROM SETPOINT X AVERAGING SENSOR LOW LIMIT TEMPERATURE STATUS X X X LOW LIMIT X COOLING COIL VALVE POSITION COMMAND X X X X 5o DELTA T ACROSS COIL WITH VALVE COMMANDED CLOSED X SUPPLY FAN MOTOR START/STOP X X X X INTERLOCK WITH FA SYSTEM SUPPLY FAN SPEED COMMAND X X X SUPPLY FAN STATUS X X X FAILURE X VIA CONTACT ON DRIVE SUPPLY FAN POWER (kW)X X X BACnet MSTP NETWORK POINT SUPPLY FAN SPEED (RPM)X X X BACnet MSTP NETWORK POINT AHU DISCHARGE AIR TEMPERATURE X X X X + / - 4 DEG F FROM SETPOINT X AHU DISCHARGE AIR TEMPERATURE SETPOINT X X X SUPPLY DUCT SMOKE DETECTOR STATUS X X REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 CONTROL SCHEMATIC & SYSTEM SUMMARY H-503B 190306 RFG RFG 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor HallNTS 1 EXISTING AIR HANDLING UNIT AHU-4 & EXISTING EXHAUST AIR FAN EF-1 CONTROL SCHEMATIC AND SYSTEM SUMMARY NTS 2 EXISTING AIR HANDLING UNIT AHU-5 CONTROL SCHEMATIC AND SYSTEM SUMMARY EF M INDICATES EXISTING EXHAUST AIR EA CS BI SS BO MS EA POINT SCHEDULE TYPICAL EXHAUST AIR FAN / TRANSFER AIR FAN HARDWARE POINTS SOFTWARE POINTS SHOWN ON GRAPHIC NOTESBIBOAIAOAV BV SCH TREND ALARM BACS EMCS DESCRIPTION FAN MOTOR START/STOP X X X FAN STATUS X X X FAILURE X VIA CURRENT SENSOR SYSTEM DESCRIPTION EXHAUST FAN GENERAL EXISTING SYSTEM SHALL BE PROVIDED WITH NEW CONTROL POINTS. ALL EXISTING CONTROL POINTS SHALL BE REMOVED AND REPLACED. SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). ALL SETPOINTS SHALL BE ADJUSTABLE. START/STOP THE FAN SHALL BE ENERGIZED AND RUN CONTINUOUSLY UPON A START COMMAND. FAN SPEED CONTROL THE FAN SHALL OPERATE AT CONSTANT SPEED WHENEVER THE SYSTEM IS INDEXED TO OPERATE. SEQUENCE OF OPERATION UNIT HEATER E AO F.O. CS AV SETPOINT REFER TO PLANS SA D T AISS BO BI EF M (E)EF EXHAUST AIR CS BI SS BO MS (E)BDD INDICATES EXISTING REFER TO PLANS SYSTEM DESCRIPTION MECHANICAL ROOM VENTILATION SYSTEM MECHANICAL ROOM EXHAUST FANS EF-2, EF-3 & EF-4 UNIT HEATERS (QUANTITY: 5) (EXISTING CONTROL POINTS ARE SHOWN DASHED AND NEW CONTROL POINTS ARE SHOWN SOLID ON THE CONTROL DIAGRAM) GENERAL EXISTING SYSTEM SHALL BE PROVIDED WITH NEW CONTROL POINTS. ALL EXISTING CONTROL POINTS SHALL BE REMOVED AND REPLACED. SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). ALL SETPOINTS SHALL BE ADJUSTABLE. SETPOINTS COOLING: 800F HEATING: 600F EXHAUST FAN CONTROL WHEN THE SPACE TEMPERATURE RISES ABOVE THE COOLING TEMPERATURE SETPOINT, THE EXHAUST FAN SHALL START AND RUN AT CONSTANT SPEED. UNIT HEATER CONTROL WHEN THE SPACE TEMPERATURE FALLS BELOW THE HEATING TEMPERATURE SETPOINT, THE UNIT HEATER SHALL BE ENERGIZED AND THE CONTROL VALVE SHALL MODULATE TO MAINTAIN THE HEATING TEMPERATURE SETPOINT. THE CONTROL VALVE SHALL BE CLOSED WHEN THE UNIT HEATER FAN IS OFF. SEQUENCE OF OPERATION POINT SCHEDULE SYSTEM CONTROL POINTS HARDWARE POINTS SOFTWARE POINTS SHOWN ON GRAPHIC NOTESBIBOAIAOAV BV SCH TREND BACS EMCS DESCRIPTION EXHAUST FAN MOTOR START/STOP X X X EXHAUST FAN STATUS X X X FAILURE X VIA CURRENT SENSOR UNIT HEATER CONTROL VALVE POSITION COMMAND X X X FAIL LAST UNIT HEATER START/STOP X X X UNIT HEATER STATUS X X X FAILURE X VIA CURRENT SENSOR SPACE TEMPERATURE X X X TEMPERATURE +/- 4 DEG F FROM SETPOINT X SPACE TEMPERATURE SETPOINT X X X OV UNIT HEATER E AO F.O. CS SS BO BI AV SETPOINT REFER TO PLANS SA D T AI INDICATES EXISTING REFER TO PLANS OV SYSTEM DESCRIPTION HORIZONTAL UNIT HEATER (EXISTING CONTROL POINTS ARE SHOWN DASHED AND NEW CONTROL POINTS ARE SHOWN SOLID ON THE CONTROL DIAGRAM) GENERAL EXISTING SYSTEM SHALL BE PROVIDED WITH NEW CONTROL POINTS. ALL EXISTING CONTROL POINTS SHALL BE REMOVED AND REPLACED. SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). ALL SETPOINTS SHALL BE ADJUSTABLE. SETPOINTS SPACE HEATING TEMPERATURE SETPOINTS: HEATING: 60 °F START/STOP THE UNIT HEATER SHALL OPERATE WHENEVER THE SPACE IS IN OCCUPIED OR UNOCCUPIED MODE TO MAINTAIN THE SPACE HEATING TEMPERATURE SETPOINT. ZONE TEMPERATURE CONTROL IF THE ZONE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING TEMPERATURE SETPOINT, THE FAN SHALL START AND THE HEATING COIL CONTROL VALVE SHALL MODULATE AS NEEDED TO MAINTAIN TEMPERATURE SETPOINT. SEQUENCE OF OPERATION POINT SCHEDULE SYSTEM CONTROL POINTS HARDWARE POINTS SOFTWARE POINTS SHOWN ON GRAPHIC NOTESBIBOAIAOAV BV SCH TREND BACS EMCS DESCRIPTION UNIT HEATER CONTROL VALVE POSITION COMMAND X X X FAIL LAST UNIT HEATER START/STOP X X X UNIT HEATER STATUS X X X FAILURE X VIA CURRENT SENSOR SPACE TEMPERATURE X X X TEMPERATURE +/- 4 DEG F FROM SETPOINT X SPACE TEMPERATURE SETPOINT X X X REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 CONTROL SCHEMATIC & SYSTEM SUMMARY H-504B 190306 RFG RFG 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor HallNTS 1 TYPICAL EXHAUST/TRANSFER AIR FAN CONTROL SCHEMATIC & SYSTEM SUMMARY NTS 2 MECHANICAL ROOM HEATING & VENTILATION CONTROL SCHEMATIC & SYSTEM SUMMARY NTS 3 TYPICAL UNIT HEATER CONTROL SCHEMATIC & SYSTEM SUMMARY CHILLED WATER LOAD SHED MATRIX CONTROL POINT LOAD SHED 1 - CHILLED WATER DAYTIME (DEFCON 3) LOAD SHED 2 - CHILLED WATER NIGHT (DEFCON 2) LOAD SHED 3 - CHILLED WATER EMERGENCY (DEFCON 1) LOAD SHED 4 - CHILLED WATER LCS EMERGENCY (DEFCON) ZONE CONTROL NON-RESEARCH SPACES INDEX SPACE TO UNOCCUPIED MODE CHILLED WATER COIL CONTROL VALVE UNDER CONTROL INDEX CHILLED WATER COIL CONTROL VALVE CLOSED CRITICAL SPACES (2)UNDER CONTROL AIR HANDLING SYSTEM CONTROL MIXED AIR FAN SYSTEMS - ATRIUM / HALLWAY INDEX DISCHARGE AIR TEMPERATURE SET POINT TO 70 DEG F (1) INDEX DISCHARGE AIR TEMPERATURE SET POINT TO 75 DEG F (1)INDEX CHILLED WATER CONTROL VALVE CLOSED INDEX TO 100% RECIRCULATION MIXED AIR FAN SYSTEMS - OFFICE/CLASSROOM/AUDITORIUM INDEX DISCHARGE AIR TEMPERATURE SET POINT TO 65 DEG F (1) INDEX DISCHARGE AIR TEMPERATURE SET POINT TO 70 DEG F (1) INDEX CHILLED WATER CONTROL VALVE CLOSED INDEX CHILLED WATER CONTROL VALVE CLOSED INDEX TO 100% RECIRCULATION MIXED AIR FAN SYSTEMS - CRITICAL (2)UNDER CONTROL 100% OUTSIDE AIR SYSTEMS - NON CRITICAL INDEX DISCHARGE AIR TEMPERATURE SET POINT TO 65 DEG F (1) INDEX DISCHARGE AIR TEMPERATURE SET POINT TO 70 DEG F (1) INDEX DISCHARGE AIR TEMPERATURE SET POINT TO 75 DEG F (1) INDEX CHILLED WATER CONTROL VALVE CLOSED 100% OUTSIDE AIR SYSTEMS - CRITICAL (2)UNDER CONTROL GENERAL EXHAUST SYSTEMS UNDER CONTROL INDEX "OFF" HYDRONIC SYSTEM CONTROL BUILDING RECIRCULATION LOOP - NON CRITICAL INDEX CHILLED WATER TEMPERATURE TO 53 DEG F INDEX PUMPS "OFF" AND OPEN RECICULATING LOOP VALVE TO 100% BUILDING RECIRCULATION LOOP - CRITICAL (2)UNDER CONTROL NOTES: (1)RETAIN FREE COOLING IF REQUIRED AND AVAILABLE (2)THE DETERMINATION OF WHETHER A SYSTEM OR ZONE IS CONSIDERED "CRITICAL" SHALL BE DETERMINED ON A CASE-BY-CASE BASIS. GENERALLY ANIMAL ROOMS, SERVER ROOMS AND LIBRARIES ARE THE ONLY SPACES THAT ARE PREQUALIFIED AS "CRITICAL" EACH PROJECT SHALL CONDUCT AN INDEPENDENT MEETING WITH THE PRIMARY PURPOSE OF MAKING LOAD SHED DECISIONS STEAM LOAD SHED MATRIX CONTROL POINT LOAD SHED-1 STEAM LOAD SHED-2 STEAM LOAD SHED-3 STEAM LOAD SHED-4 STEAM LOAD SHED-5 STEAM LOAD SHED-6 STEAM ZONE CONTROL NON-RESEARCH SPACES INDEX SPACE TO UNOCCUPIED MODE INDEX TEMPERATURE SET POINT TO 60 DEG F CRITICAL SPACES (2)UNDER CONTROL AIR HANDLING SYSTEM CONTROL MIXED AIR FAN SYSTEMS - ATRIUM / HALLWAY UNDER CONTROL INDEX TO 100% RECIRCULATION INDEX UNIT "OFF" MIXED AIR FAN SYSTEMS - OFFICE/CLASSROOM/AUDITORIUM UNDER CONTROL INDEX OUTDOOR AIR DAMPER TO MIN POSITION INDEX TO 100% RECIRCULATION INDEX UNIT "OFF" MIXED AIR FAN SYSTEMS - CRITICAL (2)UNDER CONTROL 100% OUTSIDE AIR SYSTEMS - NON CRITICAL UNDER CONTROL INDEX DISCHARGE AIR TEMPERATURE TO 55 DEG F INDEX UNIT "OFF" 100% OUTSIDE AIR SYSTEMS - CRITICAL (2)UNDER CONTROL INDEX DISCHARGE AIR TEMPERATURE TO 55 DEG F (1) GENERAL EXHAUST SYSTEMS UNDER CONTROL INDEX "OFF" HYDRONIC SYSTEM CONTROL REHEAT LOOP SYSTEM - NON CRITICAL UNDER CONTROL INDEX LOOP TEMPERATURE TO 140 DEG F OR MAINTAIN RESET SCHEDULE, WHICHEVER IS LOWER CLOSE STEAM VALVE, PUMPS "ON" REHEAT LOOP SYSTEMS - CRITICAL (2)UNDER CONTROL PERIMETER HEATING LOOP SYSTEM UNDER CONTROL INDEX LOOP TEMPERATURE TO 140 DEG F OR MAINTAIN RESET SCHEDULE, WHICHEVER IS LOWER GLYCOL HEATING LOOP SYSTEM UNDER CONTROL RADIANT HEATING LOOP SYSTEM UNDER CONTROL NOTES: (1)RETAIN ORIGINAL SET POINT IF LOWER THAN 55 DEG F. (2)THE DETERMINATION OF WHETHER A SYSTEM OR ZONE IS CONSIDERED "CRITICAL" SHALL BE DETERMINED ON A CASE-BY-CASE BASIS. GENERALLY ANIMAL ROOMS, SERVER ROOMS AND LIBRARIES ARE THE ONLY SPACES THAT ARE PREQUALIFIED AS "CRITICAL" EACH PROJECT SHALL CONDUCT AN INDEPENDENT MEETING WITH THE PRIMARY PURPOSE OF MAKING LOAD SHED DECISIONS REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 CONTROL SCHEMATIC & SYSTEM SUMMARY H-505B 190306 RFG BMA 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor HallNTS 1 CHILLED WATER LOAD SHED MATRIX NTS 2 STEAM LOAD SHED MATRIX J LP-404 HOME RUN TO PANELBOARD. LETTERS/ NUMBERS INDICATE PANEL. NUMBERS INDICATE CIRCUITS. NUMBER OF ARROWS EQUALS NUMBER OF CIRCUITS. CIRCUIT SHALL BE 20 AMP, 120 VOLT, 2-#12, 1-#12 EG., IN ƒ" C, UNLESS NOTED OTHERWISE. BRANCH CIRCUIT WIRING SIZE AND NUMBER TO MATCH HOMERUN. REFER TO SPEC'S FOR RACEWAY TYPE. , (E) (ER) COMBINATION FUSED DISCONNECT SWITCH AND MAGNETIC STARTER AMP RATING AS INDICATED ON ELECTRICAL EQUIPMENT AND CONTROL SCHEDULE M MOTOR CONNECTION. REFER TO ELECTRIC EQUIPMENT AND CONTROL SCHEDULE FOR SIZE. DISCONNECT SWITCH AMP RATING AS INDICATED ON ELECTRICAL EQUIPMENT AND CONTROL SCHEDULE VFD VARIABLE FREQUENCY DRIVE ATS SOLID HALF ARROW(S) INDICATES 120 VOLT CIRCUIT TO SINGLE POLE CIRCUIT BREAKER(S), UNLESS NOTED OTHERWISE. SOLID FULL ARROW INDICATES 208 VOLT CIRCUIT TO MULTI-POLE CIRCUIT BREAKER, UNLESS NOTED OTHERWISE. OPEN HALF ARROW(S) INDICATES 277 VOLT CIRCUIT TO SINGLE POLE CIRCUIT BREAKER(S), UNLESS NOTED OTHERWISE. OPEN FULL ARROW INDICATES 480 VOLT CIRCUIT TO MULTI-POLE CIRCUIT BREAKER, UNLESS NOTED OTHERWISE. PUSH BUTTON TV 3a,b,c TC 3-#12 & 1-#12EG IN ƒ" C. 2-#6 & 1-#10EG IN 1" C. 2-#6 & 1-#10EG IN 1" C. 3-#10 & 1-#10EG IN ƒ" C. 3-#8 & 1-#10EG IN ƒ" C. 3-#12 & 1-#12EG IN ƒ" C. 3-#10 & 1-#10EG IN ƒ" C. 208/120 VOLT PANELBOARD BL BLUE LIGHT EMERGENCY TELEPHONE. PROVIDE DEDICATED 120V EMERGENCY POWER CIRCUIT AND DEDICATED CAT6A VOICE LINE TO EACH PHONE. REFER TO CAMPUS STANDARDS. ASD D ECB , EXISTING ELECTRICAL OR EQUIPMENT OR DEVICE, DASHED LIGHT IS EXISTING TO BE REMOVED. ,HEAVY SOLID IS NEW SYMBOL DESCRIPTION POWER DISTRIBUTION AND CONTROL SYMBOL SIZE BRANCH CIRCUIT WIRE SIZES BRANCH CIRCUITING IDENTIFICATION 3 3 GENERAL DEMOLITION NOTES: WHEN EXISTING CONSTRUCTION, WHICH IS TO REMAIN, IS DAMAGED DURING THE COURSE OF DEMOLITION AS A RESULT OF THE CONTRACTOR'S WORK, IT SHALL BE REPAIRED AND/OR REPLACED WITH SIMILAR OR LIKE MATERIALS, AS MUCH AS POSSIBLE, SUBJECT TO THE OWNERS APPROVAL. THE CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND REPLACEMENT OF EXISTING CONSTRUCTION IN THE WAY OF NEW WORK. PROTECT BUILDING AND FURNISHINGS FROM DAMAGE. COORDINATE PHASING OF WORK WITH OWNER'S REPRESENTATIVE. COORDINATE ALL SHUTDOWNS WITH UNIVERSITY PRIOR TO DEMOLITION. PROVIDE A MINIMUM OF 14 DAYS NOTICE. EXISTING CONDITIONS ARE TAKEN FROM FIELD OBSERVATIONS AND PRIOR CONSTRUCTION DOCUMENTS WHEN AVAILABLE AND ARE NOT GUARANTEED. PARTICULAR CARE SHALL BE TAKEN TO AVOID CREATING HAZARD OR CAUSING DISRUPTION IN ADJOINING AREAS. NOT ALL DEVICES TERMINATIONS, JUNCTION BOXES AND WIRING HAVE BEEN SHOWN. REFER TO PLUMBING CONTRACT DRAWINGS AND SPECIFICATIONS FOR EXACT QUANTITIES AND LOCATIONS OF ALL PLUMBING EQUIPMENT BEING ABANDONED OR REMOVED, WHICH WILL REQUIRE DE-ENERGIZATION, REMOVAL AND BLANK- OFF BY THE ELECTRICAL CONTRACTOR. THE EXISTING ELECTRICAL EQUIPMENT AND DEVICES WITHIN DEMOLITION AREA SHALL BE DEMOLISHED ALONG WITH ALL FEEDERS AND CONDUITS BACK TO POINT OF SOURCE UNLESS OTHERWISE NOTED. ALL ITEMS SHOWN ON THE DEMOLITION DRAWINGS SHALL BE DISCONNECTED AND REMOVED UNLESS NOTED OTHERWISE. WALLBOXES, BACKBOXES AND CONDUIT SHALL BE REUSED AS DETERMINED BY CONTRACTOR. ALL UNUSED CONDUITS SHALL BE REMOVED. DISCONNECT AND MAKE SAFE ANY EQUIPMENT TO BE REMOVED BY OTHERS. COORDINATE REMOVAL OF EQUIPMENT WITH OTHER TRADES PRIOR TO DEMOLITION. MAINTAIN AND RESTORE, IF INTERRUPTED BY REMOVALS OR IN PATH OF NEW CONSTRUCTION, ALL CIRCUITS, CONDUITS AND FEEDERS PASSING THROUGH AND SERVING UNDISTRUBED AREAS (SHOWN OR NOT SHOWN). ALL EXISTING CONDUITS STUBBED THROUGH FLOOR SERVING ITEMS TO BE REMOVED AND NOT SHOWN OR REQUIRED TO BE REUSED, SHALL BE CUT OFF FLUSH WITH SLAB LEVEL WITH CONCRETE. IN ANY AREA REQUIRING THE PERFORMANCE OF ANY TRADE'S WORK, THIS CONTRACTOR SHALL CAREFULLY REMOVE AND STORE ANY OR ALL ECETRICAL ITEMS IN PATH OF WORK, REINSTALLING AND RECONNECTING SAME AS REQUIRED, IN ACCORDANCE WITH THE PLANS AND/OR AS DIRECTED AFTER COMPLETION O OTHER TRADE'S WORK IN THAT AREA. INVENTORY MAJOR ELECTRICAL ITEMS THAT ARE REMOVED AND PROVIDE A LIST TO THE OWNER FOR THEIR SELECTION OF ITEMS TO BE RETAINED. TURN OVER TO OWNER THE EXISTING ZONED "FACP" AND EXISTING FIRE ALARM DEVICES INDICATED TO BE REMOVED UNLESS OTHERWISE INDICATED. ALL ITEMS REJECTED BY THE OWNER SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE SITE. DISCONNECT, MAKE SAFE AND REMOVE ALL TEMPORARY AND ABANDONED WIRE WITHIN THE SPACE. BRANCH CIRCUIT WIRING TO DEVICES IN AREAS OF DEMOLITION SHALL BE DISCONNECTED, MADE SAFE AND REMOVED COMPLETELY BACK TO THE PANELBOARD. THE CONTRACTOR SHALL NOT ABANDON BRANCH CIRCUIT WIRING IN EXISTING WALLS AND CEILINGS. MAINTAIN THE CONTINUITY OF BRANCH CIRCUIT WIRING TO ANY AREAS WHICH ARE TO REMAIN BUT ARE AFFECTED BY THE DEMOLITION OR NEW CONSTRUCTION. DISCONNECT AND REMOVE PANEL, FEEDERS AND BRANCH CIRCUITS BACK TO POINT OF SOURCE PRIOR TO THE START OF DEMOLITION, CONTRACTOR SHALL FIELD VERIFY ALL BRANCH CIRCUITS AND MAINTAIN THOSE CIRCUITS THAT EXTEND OUSTIDE OF THE SCOPE OF WORK. AFTER RENOVATING EXISTING ELECTRICAL WORK, THE CONTRACTOR SHALL INSURE THAT ALL REMAINING AND NEW EQUIPMENT WILL OPERATE PROPERLY. A. B. C. D. E. F. G. H. I. J. K. L. M. N. O. ELECTRICAL SYMBOLS LIST BASIC MATERIALS AND METHODS GENERAL CONSTRUCTION SYMBOLS ELECTRICAL SYMBOLS LIST BASIC MATERIALS AND METHODS SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION 3 a,b,c JUNCTION BOX EXISTING DEVICE TO REMAIN EXISTING DEVICE TO BE RELOCATEDDUPLEX RECEPTACLE, 20 AMP, 125 VOLT CONNECT TO AN EMERGENCY CIRCUIT MOTOR STARTER. REFER TO ELECTRIC EQUIPMENT AND CONTROL SCHEDULE FOR SIZE AND TYPE. 480 VOLT PANELBOARD AUTOMATIC TRANSFER SWITCH GENERAL NOTES: MOUNTING HEIGHT & MISC. INFO. SWITCH LEG FIXTURE TYPE a B DISTRIBUTION (I-LINE TYPE) PANELBOARD EPO EMERGENCY POWER OFF PUSH BUTTON WALL PHONE FINISHED FLOOR FINISHED CEILING TEL/COMM RECEPTACLE 1'-6" PULL STATION HORN/LIGHT EXIT WARNING &SIGNAL FIXTURE/SIGNS CENTERED ABOVE DOOR LIGHT SWITCH MIN 80" AFF TO BOTTOM OF DEVICE AND MAXIMUM OF 96" AFF TO TOP OF DEVICE OPERABLE PART OF DEVICE 4'-0" 1 NLGP-B SINGLE RECEPTACLE 20 AMP, 125 VOLT SPECIAL PURPOSE RECEPTACLE. PROVIDE PROPER VOLTAGE, CLASS, CURRENT RATING AND NEMA CONFIGURATION AS REQUIRED BY BRNAHC CIRCUIT AND/OR MATCH CAP ON EQUIPMENTBEING FURNISHED BY OTHERS. PROVIDE CORD AND CAP. TELEVISION OUTLET. PROVIDE CUSTOM RECESSED BOX WITH FACEPLATE WITH 1" CONDUIT TO CABLE TRAY WITH 1 CAT 6A CABLE TO BDF AND (2) 1-1-1/4" CONDUITS TO ABOVE FINISHED CEILING FOR FUTURE USE. TORK TIME CLOCK 2-#10 & 1-#10EG IN ƒ" C. 30A, 1P 50A, 1P 60A, 1P 20A, 2P 30A, 2P 40A, 2P 20A, 3P 30A, 3P PROVIDE NEMA RECEPTACLE CONFIGURATION TO MATCH EQUIPMENT. 3' FROM EDGE OF BASE MAX. 2.THE ABOVE MOUNTING HEIGHTS SHALL BE ADHERED TO UNLESS SPECIFICALLY NOTED OR DETAILED OTHERWISE ON THE DRAWINGS OR SPECIFICATIONS. MOUNTING HEIGHTS TO CENTER OF OUTLETS UNLESS OTHERWISE NOTED. IN MASONRY CONSTRUCTION THE ABOVE MOUNTING HEIGHTS SHALL BE USED FOR REFERENCE TO NEAREST BLOCK OR BRICK COURSING. 1. DETAIL NOTES: COMPLETE CONNECTION TO EQUIPMENT. SHALL INCLUDE ALL FEEDER CONNECTIONS AND POWER FROM SOURCE AS NOTED ON DRAWINGS. ADJUSTABLE SPEED DRIVE SWITCH(DIMMING, MOMENTARY, DIGITAL, ETC.), VOLTAGE AS INDICATED ON FIXTURE SCHEDULE, SUBSCRIPTS INDICATE QUANTITY AND/OR TYPE: 3 - THREE WAY SWITCH 4 - FOUR WAY SWITCH OS - OCCUPANCY SENSOR a,b,c - SWITCHING DESIGNATIONS NUMBER OF LETTERS EQUALS NO. OF GANGED SWITCHES REFER TO SPECIFICATIONS FOR ADDITIONAL LIGHT SWITCH DESCRIPTIONS. DIMMER SWITCH, VOLTAGE AS INDICATED ON FIXTURE SCHEDULE. DIMMER SHALL BE COMPATIBLE WITH PROVIDED LIGHT FIXTURE BEING CONTROLLED BY DIMMER. IF DIMMER PROVIDED DOES NOT OPERATE WITH A VACANCY SENSOR A DECORA STYLE ON/OFF SWITCH SHALL BE PROVIDED IN SAME SWITCH BOX. SUBSCRIPTS INDICATE TYPE: 3 - THREE WAY DIMMER SWITCH 4 - FOUR WAY SWITCH a,b,c - SWITCHING DESIGNATIONS NUMBER OF LETTERS EQUALS NO. OF GANGED SWITCHES DUPLEX RECEPTACLE, 20 AMP, 125 VOLT SUBSCRIPTS INDICATE TYPE: OC - OVER COUNTER WP - WEATHER PROOF GFI - GROUND FAULT INTERUPT UC - UNDER THE COUNTER TV - TV RECEPTACLE, COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL AND A/V DRAWINGS AV - AV RECEPTACLE, COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL AND A/V DRAWINGS. ENCLOSED CIRCUIT BREAKER SEE ARCHITECTURAL ELEVATIONS SEE ARCHITECTURAL ELEVATIONS SEE ARCHITECTURAL ELEVATIONS SLEEVE AND SEAL ALL WALL AND FLOOR PENETRATIONS. PROVIDE FIRESTOPPING FOR ALL FIRE-RATED PENETRATIONS. UTILIZE REMOVABLE FIRESTOPPING MATERIAL AT CABLE TRAY PENETRATIONS. PROVIDE ACOUSTICAL SEALANT FOR ALL NON RATED PENETRATIONS. ALL FIRE RATINGS SHALL BE MAINTAINED. MAINTAIN SERVICE CLEARANCES OF ALL EQUIPMENT. COORDINATE EXACT LOCATION OF ALL CONDUIT ROUTES, EQUIPMENT AND DEVICES WITH EXISTING CONDITIONS PRIOR TO CONSTRUCTION. MINIMUM CONDUIT SIZE SHALL BE ƒ" FOR POWER CIRCUITS UNLESS OTHERWISE NOTED. PROVIDE NYLON PULLSTRING IN ALL EMPTY CONDUITS. FIRE ALARM SIGNALING APPLIANCES SHALL BE MOUNTED SUCH THAT THE ENTIRE LENS IS NOT LESS THAN 80 INCHES AND NOT GREATER THAN 96 INCHES ABOVE THE FINISHED FLOOR. CIRCUITING TO DEVICES/EQUIPMENT SHALL BE 2-#12AWG & 1-#12EG (MULTIPLE HOME RUNS IN SAME CONDUIT MAY SHARE SAME EQUIPMENT GROUND) FOR EACH 20 AMPERE CIRCUIT UNLESS OTHERWISE NOTED. ALL CIRCUITS SHALL HAVE SEPARATE NEUTRALS (CIRCUITS SHALL NOT SHARE NEUTRALS). PROVIDE CONDUIT/WIRING (CIRCUITING) AND REQUIRED EQUIPMENT CONNECTIONS TO ALL DEVICES/EQUIPMENT. CONNECT TO CIRCUIT(S) AS INDICATED. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF NFPA CODES, FIRE CODE OF NEW YORK STATE, BUILDING CODE OF NEW YORK STATE AND SUNY FREDONIA DESIGN STANDARDS. A. B. C. D. E. F. G. H. I. REFERENCE TO DRAWING NOTE REFERENCE TO DEMOLITION NOTE EXISTING WIRING OR EQUIPMENT, SOLID LIGHT IS EXISTING TO REMAIN OR EXISTING TO BE RELOCATED. 1 PANEL DESIGNATIO N TYPICAL FOR ALL DEVICES AND HOMERUNS GFI NUMBER INDICATES CIRCUIT NUMBER CIRCUIT NUMBER NUMBER INDICATES CIRCUIT2 NOTE: CIRCUIT BREAKER GROUND FAULT INTERRUPTING MLO MAIN LUG ONLY MICRO AFF CB GFI MCB EG EQUIPMENT GROUND FCU FAN COIL UNIT AFG AWG AMERICAN WIRE GAGE ABOVE FINISHED GRADE ABBREVIATIONS UOI OFCI WP TSP UC OC TWISTED SHIELDED PAIR UNLESS OTHERWISE INDICATED OWNER FURNISHED, CONTRACTOR INSTALLED CLG.CEILING A.AMPERE EXIST.EXISTING MAIN CIRCUIT BREAKER GND. KW. GROUND KILOWATT ABBREV. C. HP. CONDUIT ABOVE FINISHED FLOOR PH.PHASE PNL.PANEL REFRIG. TYP. SP.SPACE POLE SW. 4 W.WIRE 3P.15A. ABBREV. P. PP REFRIGERATOR POWER PANEL SWITCH TYPICAL WEATHERPROOF MOUNTED UNDER COUNTER HEIGHT MOUNTED OVER COUNTER HEIGHT P = POLE A = AMPERE DESCRIPTION NIC NOT IN CONTRACT LS LIFE SAFETY BRANCH CR EQ CRITICAL BRANCH EQUIPMENT BRANCH HORSEPOWER MICROWAVE DESCRIPTION VOLTV. VAV VARIABLE AIR VOLUME EQUIPMENT: "INSERT DESIGNATION" FEEDER: "INSERT FEEDER DESIGNATION" TYPE SUPPLY: "INSERT-NORMAL, EQUIPMENT EMEREGENCY, LIFE SAFETY EMERGENCY AS APPLICABLE" VOLTAGE: "INSERT APPLICABLE VOLTAGE - 208/120V OR 480/277V, ETC." COLOR CODING: PHASE A - "BLACK OR BROWN" PHASE B - "RED OR ORANGE" PHASE C - "BLUE OR YELLOW" NEUTRAL - "WHITE OR GRAY" GROUND - GREEN PROVIDE CUSTOM NAMEPLATE AS INDICATED FOR ALL PANELBOARDS, MCC'S, SWITCHBOARDS, SWITCHGEAR, TRANSFER SWITCHES, GENERATORS ETC. NAMEPLATE SHALL BE ENGRAVED (WHITE LETTERING, BLACK BACKGROUND) AND ATTACHED TO THE EQUIPMENT WITH BRASS SCREWS. LETTERING SHALL BE 1/4" HIGH EXCEPT WARNING LINE TO BE 3/8". SPACE BETWEEN LINES SHALL BE 1/8" MINIMUM. MINIMUM SHALL BE 14"H x 8"W. PROVIDE SAMPLE NAMEPLATE FOR REVIEW. B. A. NOTES: C. REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 GENERAL NOTES, SYMBOLS LIST - ELEC E-000B 190306 MRG JFR 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor HallNTS 1 EQUIPMENT NAMEPLATE DETAIL UP DN DN DN M M M M M M M M M M M M M M M M M M M M ---COURT YARD ---OPEN TO BELOW ---OPEN TO BELOW ---OPEN TO BELOW 1854182 15010022 72180 53182A6210059 2210076 18111868510058 13110057 15110029 114186A 26710066 42991842303181 2910023 28184A 28184B 3110028 124100102610074 2210061 710069 3051000717610035 3510037 13719011610012 2210042 UP DN DN UP UP UP DN UP DN UP UP UP UP DN UP UP DN DN UP UP UP UP DN DN DN DN 40001 130 40040 112 476 239 477 220 478 176 470 6,238 40015 17 40072 15 OPEN TO BELOW --- 40045 186 40046 127 40066 36 40049 94 40044 15940003 69 474 87 40069 2,514 ROOF --- 40068 3,857 473 84 472 85 471 79 40076 10 OPEN TO BELOW --- 479 497 40009 23 MCC-1(E) EF-2(E) UH-4-2(E) RAF-2(E) EF-10(E) EF-C(E) EF-A(E) EF-B(E) UH-4-1(E) AHU-1(E) AHU-2(E) RAF-1(E) EF-12(E) EF-3(E) UH-4-3(E) EF-4(E) UH-4-4(E) EF-1(E) AHU-4(E) AHU-3(E) UH-4-5(E) NORTH REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 PARTIAL FOURTH FLOOR PLAN - DEMOLITION - ELECTRICAL E-100B 190306 MRG JFR 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor Hall1/8" = 1'-0" 1 PARTIAL FOURTH FLOOR PLAN - DEMOLITION - ELECTRICAL DEMOLITION NOTES 1 REWORK AND SALVAGE 120V CONNECTION TO AAD FOR REUSE IN NEW CONSTRUCTION. GENERAL NOTES A. CONTRACTOR SHALL DISCONNECT AND REMOVE 120V CONNECTION FROM EXISTING CONTROL PANELS TO EXISTING PNEUMATIC AAD DEVICES. NTS A KEYPLAN - E-100B DN UP DN UP DN UP DN ---COURT YARD ---OPEN TO BELOW ---OPEN TO BELOW ---OPEN TO BELOW 1854182 15010022 72180 53182A6210059 2210076 18111868510058 13110057 15110029 114186A 26710066 42991842303181 2910023 28184A 28184B 3110028 124100102610074 2210061 710069 3051000717610035 3510037 13719011610012 2210042 UP DN DN UP UP UPDN UP DN UP UP UP UP DN UP UP DN DN UP UP UP UP DN DN DN DN 381 156 380 194 378A 811 378 6894 30041 255 30009 84 30079 41 376A 188 30048 288 375 140 375A 277 374 971 376 691 377 633 30063 89 30072 15 30015 32 373 185 372 268 370 2302 30017 25 370A 162 370B 133 30040 220 30001 129 302 308 302A 9 304 290 304A 8 306A 8 306 310 308A 7 308 275 310 246 312 283 314 251 316 252 318 250 320 251 322 251 324 244 340A 140 340B 123 340C 226 310A 7 312A 7 314A 7 316A 6 318A 6 320A 6 322A 6 324A 6 30042 1015 315A 68 323 31 30061 54 30020 163 30021 166 321 131 319 119 317 106 315 715 309 112 307 167 303 184 302 102 OPEN TO BELOW --- 30002 87 30049 25930045 164 30066 34 30065 40 30046 132 349 101 30044 75 340E 213 30003 166 353 192 355 184 359 214 30049 448 350 203 352 126 30078 8 360 282 363 125 365 201 360A 43 30050 94 30006 47 340D 174 340 1538 30011 200 381 156 380 194 378A 811 378 6894 30041 255 30009 84 30079 41 376A 188 30048 288 375 140 375A 277 374 971 376 691 377 633 30063 89 30072 15 30015 32 373 185 372 268 370 2302 30017 25 370A 162 370B 133 30040 220 30001 129 302 308 302A 9 304 290 304A 8 306A 8 306 310 308A 7 308 275 310 246 312 283 314 251 316 252 318 250 320 251 322 251 324 244 340A 140 340B 123 340C 226 310A 7 312A 7 314A 7 316A 6 318A 6 320A 6 322A 6 324A 6 30042 1015 315A 68 323 31 30062 6130061 54 30020 163 30021 166 321 131 319 119 317 106 315 715 309 112 307 167 303 184 302 102 OPEN TO BELOW --- 30002 87 30049 25930045 164 30066 34 30065 40 30046 132 349 101 30044 75 340E 213 30003 166 353 192 355 184 359 214 30049 448 350 203 352 126 30078 8 360 282 363 125 365 201 360A 43 30050 94 30006 47 340D 174 340 1538 30011 200 381 156 380 194 378A 811 378 6894 30041 255 30009 84 30079 41 376A 188 30048 288 375 140 375A 277 374 971 376 691 377 633 30063 89 30072 15 30015 32 373 185 372 268 370 2302 30017 25 370A 162 370B 133 30040 220 30001 129 302 308 302A 9 304 290 304A 8 306A 8 306 310 308A 7 308 275 310 246 312 283 314 251 316 252 318 250 320 251 322 251 324 244 340A 140 340B 123 340C 226 310A 7 312A 7 314A 7 316A 6 318A 6 320A 6 322A 6 324A 6 30042 1015 315A 68 323 31 30061 54 30020 163 30021 166 321 131 319 119 317 106 315 715 309 112 307 167 303 184 302 102 OPEN TO BELOW --- 30002 87 30049 25930045 164 30066 34 30065 40 30046 132 349 101 30044 75 340E 213 30003 166 353 192 355 184 359 214 30049 448 350 203 352 126 30078 8 360 282 363 125 365 201 360A 43 30050 94 30006 47 340D 174 340 1538 30011 200 H3(E) L3(E)EH3(E) L3C(E) NORTH REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 PARTIAL THIRD FLOOR PLAN - NEW WORK - ELECTRICAL E-200B 190306 MRG JFR 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor Hall1/8" = 1'-0" 1 PARTIAL THIRD FLOOR PLAN - NEW WORK - ELECTRICAL NTS A KEYPLAN - E-200B UP DN DN DN M M M M M M M M M M M M M M M M M M M M ---COURT YARD ---OPEN TO BELOW ---OPEN TO BELOW ---OPEN TO BELOW 1854182 15010022 72180 53182A6210059 2210076 18111868510058 13110057 15110029 114186A 26710066 42991842303181 2910023 28184A 28184B 3110028 124100102610074 2210061 710069 3051000717610035 3510037 13719011610012 2210042 UP DN DN UP UP UPDN UP DN UP UP UP UP DN UP UP DN DN UP UP UP UP DN DN DN DN 40001 130 40040 112 476 239 477 220 478 176 470 6,238 40015 17 40072 15 OPEN TO BELOW --- 40045 186 40046 127 40066 36 40049 94 40044 15940003 69 474 87 40069 2,514 ROOF --- 40068 3,857 473 84 472 85 471 79 40076 10 OPEN TO BELOW --- 479 497 40009 23 MCC-1(E) RELIEF AAD RETURN AAD OUTSIDE AADMIN OUTSIDE AAD RELIEF AAD RETURN AAD OUTSIDE AAD MIN OUTSIDE AAD RELIEF AAD RETURN AAD MIN OUTSIDE AAD OUTSIDE AAD AAD AAD 4 3 4 3 3 3 1 1 11 2 2 2 2 EF-B(E) EF-A(E) EF-C(E) EF-10(E) RAF-2(E) AHU-2(E) AHU-1(E) UH-4-1(E) RAF-1(E) EF-12(E) EF-3(E) UH-4-3(E) UH-4-2(E) EF-2(E) EF-4(E) UH-4-4(E) EF-1(E) AHU-4(E) UH-4-5(E) AHU-3(E) NORTH REVISIONS No.Date By Description DRAWING TITLE DRAWING NO. ISSUE DATE Drawn By: Checked By: Project Mgr: Project No: THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS AND PLANS INDICATED THEREON OR REPRESENTED THEREBY ARE OWNED BY AND REMAIN THE PROPERT OF M/E ENGINEERING AND NO PART THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT W/ THE SPECIFIC WRITTEN PERMISSION 2020 M/E ENGINEERING, P.C.c NEER NGENG Mechanical/Electrical Engineering Consultants www.meengineering.com SchenectadySyracuseRochester 585.288.5590 Buffalo 300 TROLLEY BLVD. ROCHESTER, NY 14606 PARTIAL FOURTH FLOOR PLAN - NEW WORK - ELECTRICAL E-201B 190306 MRG JFR 01/29/2021 RFGCORNELL UNIVERSITY BUILDINGCONTROLS UPGRADE 2021ITHACA, NEW YORKBID DOCUMENTSPACKAGE B -BUILDING 2021Myron Taylor Hall1/8" = 1'-0" 1 PARTIAL FOURTH FLOOR PLAN - NEW WORK - ELECTRICAL DRAWING NOTES 1 AAD IS TO BE POWERED BY PANEL L3C, SPARE 20A-1P BREAKER, CIRCUIT NUMBER 2. UTILIZE EXISTING SPARE BREAKER LOCATED IN PANEL, WIRING SHALL BE (2)#12AWG & (1) #12EG IN 3/4" CONDUIT. . 2 AAD IS TO BE POWERED BY PANEL L3C, SPARE 20A-1P BREAKER, CIRCUIT NUMBER 4. UTILIZE EXISTING SPARE BREAKER LOCATED IN PANEL, WIRING SHALL BE (2)#12AWG & (1) #12EG IN 3/4" CONDUIT 3 AAD IS TO BE POWERED BY PANEL L3C, SPARE 20A-1P BREAKER, CIRCUIT NUMBER 6. UTILIZE EXISTING SPARE BREAKER LOCATED IN PANEL, WIRING SHALL BE (2)#10AWG & (1) #12EG IN 3/4" CONDUIT. 4 AAD IS TO BE POWERED BY PANEL L3C, SPARE 20A-1P BREAKER, CIRCUIT NUMBER 8. UTILIZE EXISTING SPARE BREAKER LOCATED IN PANEL, WIRING SHALL BE (2)#10AWG & (1) #12EG IN 3/4" CONDUIT. GENERAL NOTES A. CONTRACTOR SHALL DISCONNECT AND REMOVE 120V CONNECTION FROM EXISTING CONTROL PANELS AND EXTEND & REWORK AS REQUIRED TO NEW CONTROL PANELS. WIRING SHALL BE (2)#12AWG & (1)*12EG IN 3/4" CONDUIT, UNLESS OTHERWISE NOTED. B. COORDINATE FINAL LOCATION OF ALL AAD DEVICES IN FIELD WITH MECHANICAL CONTRACTOR. NTS A KEYPLAN - E-201B