HomeMy WebLinkAboutFull FPDRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:COLLEGETOWNTERRACE APARTMENTSITHACA, NYNOVARR MACKESEYDEVELOPMENTPROFESSIONAL LICENSENUMBER:NEW YORK STATE SEAL:a r c h i t e c t sikon.5PROJECT NO.:P58.00VERSIONSNO.DATEDESCRIPTIONCIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICALENGINEER:LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:12923JULY 1, 2011107.01.2011SEQUENCE 1 - CONSTRUCTION DOCUMENTSKEY PLAN208.10.2011SEQUENCE 1 - CONSTRUCTION DOCUMENTSFIRE PROTECTION SYMBOL LIST ANDSTANDARD NOTESBRDFP0.01FIRE PROTECTION SYMBOL LISTFFIRE PROTECTION SERVICE OR MAIN (F)SSPRINKLER MAIN/BRANCH (SPR)DFIRE PROTECTION DRAIN (DR)DRY PIPE VALVE WITH TRIMRISER CHECK VALVECHECK VALVEDOUBLE CHECK VALVE ASSEMBLYSUPERVISED CONTROL VALVEPENDENT SPRINKLER, (DP) = DRY PENDENTRESIDENTIAL PENDENT SPRINKLERUPRIGHT SPRINKLERSIDE WALL SPRINKLER, (DS) = DRY SIDEWALLRESIDENTIAL SIDEWALL SPRINKLERSPRINKLER WITH GUARDELECTRIC WATERFLOW ALARM BELLELBOW DOWNDROP CONNECTION, RISE CONNECTIONCAP OR PLUGGENERAL NOTES - ALL DRAWINGS:A.PROVIDE A COMPLETE AUTOMATIC WET AND DRY PIPE SPRINKLER SYSTEM FORAREAS INDICATED IN ACCORDANCE WITH NFPA 13-2007. REFER TO FIRE PROTECTIONSPECIFICATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. DRY PIPESYSTEM SHALL BE PROVIDED FOR ATTIC. ALL OTHER SPACES SHALL BE PROVIDEDWITH WET PIPE SYSTEMS.B.PIPING AS SHOWN IS DIAGRAMMATIC, NOT ALL PIPING IS INDICATED. CONTRACTOR ISRESPONSIBLE FOR FINAL SPRINKLER SYSTEM PIPE SIZING/LAYOUT, SPRINKLERHYDRAULIC CALCULATIONS, AND COORDINATION WITH LIGHTS FIXTURES/FIRE ALARMDEVICES, DUCTWORK AND DIFFUSERS.C.MAINTAIN SPRINKLER LAYOUT AND PIPE SIZES AS INDICATED. FINAL PIPE SIZINGSHALL BE DETERMINED BY CONTRACTOR HYDRAULIC CALCULATIONS SUBJECT TOAPPROVAL BY ENGINEERD.SPRINKLER DESIGN CRITERIA; WET PIPE NFPA 13-2007 EDITION AND AS FOLLOWS:1.RESIDENTIAL ROOMS (DWELLING UNITS): 0.10 GPM/SQ.FT. OVER HYDRAULICALLYMOST REMOTE 4 SPRINKLERS. 100 GPM HOSE STREAM DEMAND.2.AREAS OUTSIDE DWELLING UNITS (LOUNGES, STORAGE, CORRIDOR, MUTLI-PURPOSEROOMS, ETC.): 0.10 GPM/SQ.FT. OVER 1500 SQ.FT., 100 GPM HOSE STREAM DEMAND,MAX. SPRINKLER SPACING OF 196 SQ. FT.3.MECH SPACES (STORAGE, ETC): 0.15 GPM/SQ.FT. OVER 1500 SQ.FT., 250 GPM HOSESTREAM DEMAND, MAX. SPRINKLER OF 130 SQ. FT.4.ATTIC SPACES (DRY SYSTEM): 0.15 GPM/SQ.FT. OVER 2535 SQ. FT., 100 GPM HOSESTREAM DEMAND, MAX. SPRINKLER SPACING OF 120 SQ.FT.E.FIRE STOP EACH WALL, CEILING, OR FLOOR PENETRATION BETWEEN SLEEPINGROOMS AND OTHER SPACES. FIRE STOP ALL PENETRATIONS THROUGH RATEDWALLS, FLOORS, CEILINGS AND PENETRATIONS THROUGH WOOD I-JOISTS.F.PIPING SHALL BE INSTALLED CONCEALED ABOVE FINISHED CEILINGS, I.E. GYP, ACT.G.PIPING SHALL BE INSTALLED EXPOSED ONLY IN UNFINISHED CEILING SPACES, I.E.MECH/ELEC/STORAGE ROOMS, STAIRWELLS, ETC.H.ALL EXPOSED PIPING SHALL BE BLACK STEEL. CPVC PIPING PERMITTED FORCONCEALED PIPING ONLY.I.SPRINKLERS SHALL BE LOCATED A MINIMUM OF 24 INCHES FROM SIDE OF DIFFUSER.COORDINATE FINAL LOCATIONS OF SPRINKLERS WITH MECHANICAL CONTRACTORPRIOR TO INSTALLATION.J.PROVIDE SPRINKLERS FOR ALL CLOSETS REGARDLESS OF NFPA CLASSIFICATION.FDCFIRE DEPARTMENT CONNECTION PIPING (FDC)AIR COMPRESSOR FOR DRY SYSTEMAC5" STORZ FIRE DEPARTMENT CONNECTIONDSDRY SPRINKLER MAIN/BRANCH (DS)1.0 - LEVEL ANFPA 13 - DRYNFPA 14 - WET1.1 - LEVEL B,C, & DNFPA 13 - WETNFPA 14 - WETNO ATTICBUILDING 1BUILDING 22.0 - LEVEL BNFPA 13 - DRY2.1 - LEVEL C,D,ENFPA 13 - WETNO ATTIC2.2 - LEVEL C,D,ENFPA 13 - WETNO ATTIC2.3 - LEVEL C,D,ENFPA 13 - WET2.3 - LEVEL FNFPA 13 - DRY2.4 - LEVEL ANFPA 13 - WET & DRYNFPA 14 - WET2.4 - LEVEL B,C,DNFPA 13R - WETNFPA 14 - WETATTIC SPRINKLERS NOTREQUIREDBUILDING 44.0 - LEVEL ANFPA 13 - DRY4.1 - LEVEL B,C,DNFPA 13R - WETATTIC SPRINKLERS NOTREQUIRED4.2 - LEVEL B,C,DNFPA 13R - WETATTIC SPRINKLERS NOTREQUIRED4.3 - LEVEL B,C,DNFPA 13R - WETATTIC SPRINKLERS NOTREQUIREDFIRE PROTECTION NFPA CLASSIFICATIONS AND SYSTEM TYPES4.4, 901 - LEVEL A, B,C,DNFPA 13 - WET, DRY ATTICSHUT OFF VALVE/TEST & DRAINGAUGE3308.17.2012SEQUENCE 2C - CONSTRUCTION DOCUMENTS
DSDSDS212"S DN1"S UP1"S UP1"S UP1"S UP4"DS UP & DN1"S UP4"DS DN4"DS UP1"S UP2"S212"S212"S2"S2"S212"S DN212"S212"S212"S212"S UPUP2 12"S UP3"S2"S1" DRAIN TOEXTERIOR4"FDC6" CONT. TO SITEUNDERGROUND4" DOUBLE CHECKBACKFLOW PREVENTER4" RISER CHECK VALVE3"S4"DS UP4"DS4"DS4"DS3"S212"SAC4" DRY PIPE VALVE WITH TRIM1" DRAIN TOEXTERIOR1"D2"S2"SPROVIDE VERTICAL SOFFITWITH LOCKABLE ACCESSPANEL FOR ENCLOSUREOF PIPING AND ACCESS TOVALVEPROVIDE VERTICAL SOFFITWITH LOCKABLE ACCESSPANEL FOR ENCLOSUREOF PIPING AND ACCESS TOVALVE1"D4"DS UP4"DS212"S UP212"S4" CONT. TO FREESTANDING FDC4"S4"SDRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:COLLEGETOWNTERRACE APARTMENTSITHACA, NYNOVARR MACKESEYDEVELOPMENTPROFESSIONAL LICENSENUMBER:NEW YORK STATE SEAL:a r c h i t e c t sikon.5PROJECT NO.:P58.00VERSIONSNO.DATEDESCRIPTIONCIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICALENGINEER:LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:12923NORTHPROJECT
08'16'32'KEY PLANBUILDING 4.4 FLOOR PLAN - LEVEL A AND BBRDFP2.44A1/4"=1'0"BUILDING 4.4 FLOOR PLAN - LEVEL A11/4"=1'0"BUILDING 4.4 FLOOR PLAN - LEVEL B2GENERAL NOTES:A.REFER TO FP0.01 FOR GENERAL NOTES ANDREQUIREMENTS.B.PROVIDE SPRINKLER PROTECTION FOR ALLCOMBUSTIBLE CONCEALED SPACES INACCORDANCE WITH NFPA 13.1" FEEDS3 SPRINKLER114" FEEDS6 SPRINKLERS112" FEEDS8 SPRINKLERS2" FEEDS12 SPRINKLERSSPRINKLER BRANCH PIPE SIZING TABLEFOR USE IN HYDRAULIC CALCULATIONS(UNLESS NOTED OTHERWISE)WATER SUPPLY INFORMATIONSTATIC PRESSURE: 80 PSIRESIDUAL PRESSURE: 73 PSIFLOW: 1131 GPMDATE: 2011LOCATION: HYDRANTS M-133 &M-75 ADJACENT TO EAST STATESTREETJANUARY 9, 201201.09.2012SEQUENCE 1 - CONSTRUCTION CHANGEDIRECTIVE 1314"FDC208.17.2012SEQUENCE 2C - CONSTRUCTION DOCUMENTS2222222222222222
DN4"DS UP& DN4"DS DN4" CONT. TO DRY SYSTEMFOR COMBUSTIBLECONCEALED SPACES INATTIC1"S DN (TYP.)2"S DN1"S DNPROVIDEWINDOWSPRINKLERSDNDNUP212"SDN2"S UP1"S UP1"S UP1"S UP1"SUP1"S UP1"S UP2"S4"DS UP & DN4" DS UP & DN212" CONT. TO DRY SYSTEMFOR COMBUSTIBLECONCEALED SPACES ONLEVEL C1"S DN (TYP.)4"DSDN4"DSUP1"S UPDRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:COLLEGETOWNTERRACE APARTMENTSITHACA, NYNOVARR MACKESEYDEVELOPMENTPROFESSIONAL LICENSENUMBER:NEW YORK STATE SEAL:a r c h i t e c t sikon.5PROJECT NO.:P58.00VERSIONSNO.DATEDESCRIPTIONCIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICALENGINEER:LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:12923NORTHPROJECT
08'16'32'KEY PLANBUILDING 4.4 FLOOR PLAN - LEVEL C AND D BRDFP2.44B1/4"=1'0"BUILDING 4.4 FLOOR PLAN - LEVEL C11/4"=1'0"BUILDING 4.4 FLOOR PLAN - LEVEL D21KEYED NOTES:PROVIDE DRY PIPE SYSTEM FOR COMBUSTIBLECONCEALED ATTIC SPACES WITHIN OUTLINEDAREA.INSTALL PIPING EXPOSED BELOW CEILING.212" CONT. TO DRY SYSTEM FOR COMBUSTIBLECONCEALED SPACES ON LEVEL D.GENERAL NOTES:A.REFER TO FP0.01 FOR GENERAL NOTES ANDREQUIREMENTS.B.PROVIDE SPRINKLER PROTECTION FOR ALLCOMBUSTIBLE CONCEALED SPACES INACCORDANCE WITH NFPA 13.1" FEEDS3 SPRINKLER114" FEEDS6 SPRINKLERS112" FEEDS8 SPRINKLERS2" FEEDS12 SPRINKLERSSPRINKLER BRANCH PIPE SIZING TABLEFOR USE IN HYDRAULIC CALCULATIONS(UNLESS NOTED OTHERWISE)KEYED NOTES:PROVIDE DRY PIPE SYSTEM FOR COMBUSTIBLECONCEALED ATTIC SPACES WITHIN OUTLINEDAREA.INSTALL PIPING EXPOSED BELOW CEILING.1223JANUARY 9, 201201.09.2012SEQUENCE 1 - CONSTRUCTION CHANGEDIRECTIVE 131208.17.2012SEQUENCE 2C - CONSTRUCTION DOCUMENTS2222
EXIST. RIDGEEXIST. RIDGE EXIST. RIDGE
EXIST. RIDGE4"DS DN4" CONT. TO DRY SYSTEMFOR COMBUSTIBLECONCEALED SPACES INATTICDRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:COLLEGETOWNTERRACE APARTMENTSITHACA, NYNOVARR MACKESEYDEVELOPMENTPROFESSIONAL LICENSENUMBER:NEW YORK STATE SEAL:a r c h i t e c t sikon.5PROJECT NO.:P58.00VERSIONSNO.DATEDESCRIPTIONCIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICALENGINEER:LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:12923NORTHPROJECT
08'16'32'KEY PLANBUILDING 4.4 FLOOR PLAN - LEVEL EBRDFP2.44C1/8"=1'0"BUILDING 4.4 FLOOR PLAN - LEVEL E11KEYED NOTES:PROVIDE DRY PIPE SYSTEM IN COMBUSTIBLECONCEALED ATTIC SPACES WITHIN OUTLINEDAREA.GENERAL NOTES:A.REFER TO FP0.01 FOR GENERAL NOTES ANDREQUIREMENTS.1" FEEDS3 SPRINKLER114" FEEDS6 SPRINKLERS112" FEEDS8 SPRINKLERS2" FEEDS12 SPRINKLERSSPRINKLER BRANCH PIPE SIZING TABLEFOR USE IN HYDRAULIC CALCULATIONS(UNLESS NOTED OTHERWISE)JANUARY 9, 201201.09.2012SEQUENCE 1 - CONSTRUCTION CHANGEDIRECTIVE 131208.17.2012SEQUENCE 2C - CONSTRUCTION DOCUMENTS
DRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:COLLEGETOWNTERRACE APARTMENTSITHACA, NYNOVARR MACKESEYDEVELOPMENTPROFESSIONAL LICENSENUMBER:NEW YORK STATE SEAL:a r c h i t e c t sikon.5PROJECT NO.:P58.00VERSIONSNO.DATEDESCRIPTIONCIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICALENGINEER:LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:12923JULY 1, 2011107.01.2011SEQUENCE 1 - CONSTRUCTION DOCUMENTSKEY PLAN208.10.2011SEQUENCE 1 - CONSTRUCTION DOCUMENTSFIRE PROTECTION DETAILSBRDFP5.01GENERAL NOTES:A.ABOVE DETAIL IS FOR GENERAL ARRANGEMENT OF VALVES AND ASSOCIATED EQUIPMENT. REFER TO FLOOR PLANS FORQUANTITY OF VALVES AND LOCATIONS OF INCOMING SERVICES.B.ALL POWER SUPPLIES AND CONNECTIONS FOR TAMPER SWITCHES, FLOW SWITCH AND ELECTRIC ALARM BELLS TO FIRE ALARMSYSTEM SHALL BE BY ELECTRICAL CONTRACTOR.TERMINATE 2" MAIN DRAIN AT FLOOR DRAIN ORTO EXTERIOR2" MAIN DRAIN (TYPICAL)RISER CHECK VALVEWATER PRESS. GAUGES(TYPICAL)CONTROL VALVE WITHTAMPER SWITCH, LOCK ANDCHAIN (TYPICAL)DRY PIPE VALVE WITHTRIM3/4"AIRFIRE PROTECTION AIR COMPRESSORAIR PRESSURE GAUGELOW AIR PRESSURE SUPERVISORYSWITCHAUTO AIR MAINTENANCEDEVICEWATERPRESSUREGAUGEWATERFLOWPRESSURESWITCHFLOWSWITCH(TYPICAL)6" CONTINUEDTO SITE WATERSUPPLY4" DOUBLE CHECK VALVEBACKFLOW PREVENTERASSEMBLYSTEEL BRAIDEDCONNECTIONFINISHEDGRADETO WET SPRINKLERSYSTEMTO DRY SPRINKLERSYSTEMDATE:3/4" BALL DRIP VALVEWITH 3/4" COPPERDRAIN TO EXTERIOR ORFLOOR DRAINFINISHED GRADESTORZ CONNECTIONAPPROXIMATELY 3 FT.ABOVE FINISHED GRADECAULK AROUND WALLESCUTCHEONFIRE DEPARTMENTCONNECTION GRAPHIC SIGNCAULK SEALANTFIRE PROTECTIONFEED MAINANCHOR PIPE TO WALLEXTERIOR WALLCHECK VALVEELECTRIC WATERFLOWALARM BELL APPROXIMATELY10' ABOVE FINISHED GRADE1/2" CONDUIT BYELECTRICAL CONTRACTORPIPE STAND MIN. 2" SCH 40 PIPING (TYPICAL)NO SCALEWET AND DRY SPRINKLER RISER DETAIL2NO SCALEFIRE DEPARTMENT CONNECTION-GENERAL54" MIN.12" MAX.CEILINGPACK MINERAL-WOOL TO CENTERAND SUPPORT SPRINKLER FROMMOVEMENT AND PROVIDE BACKINGFOR FIRE CAULKWALLFIRE CAULK AT APPROPRIATE RATINGCEILINGNO SCALESIDEWALL SPRINKLER INSTALLTION3GENERAL NOTES:A.ALL POWER SUPPLIES AND CONNECTIONS FOR ELECTRIC WATERFLOW ALARM BELL TO FIRE ALARMSYSTEM SHALL BE BY ELECTRICAL CONTRACTOR.UPRIGHT PENDENT DETAILGENERAL NOTES:A.WHERE PENDENT STYLE HEADS ARE INDICATED AND AN ACOUSTICAL TILE CEILING IS TO BE INSTALLED,INSTALL PENDENT HEADS CENTERED IN BOTH DIRECTIONS WITH A MAXIMUM DEVIATION OF 1/2" FROMCENTER OF TILE.NO SCALETYPICAL SPRINKLER DETAILSEMI-RECESSED DETAILTO FIREDEPARTMENTCONNECTIONSCAPPED TEECONNECTION1NO SCALEFREE STANDING FIRE DEPARTMENT CONNECTION4308.17.2012SEQUENCE 2C - CONSTRUCTION DOCUMENTS