HomeMy WebLinkAboutFull ElectricalELECTRICAL SYMBOL LIST ANDSTANDARD NOTESKSOE0.01ELECTRICAL SYMBOL LISTEXISTING EQUIPMENT/WORK.NEW EQUIPMENT/WORK.3REFERENCE TO DRAWING NOTEEWCELECTRIC WATER COOLERACABOVE COUNTERAFFABOVE FINISHED FLOORGFI GFCIGROUND FAULT CIRCUIT INTERRUPTER TYPE RECEPTACLEWGWIRE GUARDWPWATERPROOF (OR) WEATHERPROOFCCONDUITBRANCH CIRCUIT TO PANELBOARD, WHEN SHOWN,LETTERING INDICATES PANELBOARD DESIGNATIONS.QUANTITY OF ARROWHEADS INDICATE QUANTITY OFBRANCH CIRCUITS. PROTECT EACH BRANCH CIRCUIT WITHA 20 AMPERE, 1-POLE OVERCURRENT DEVICE UNLESSOTHER SIZE INDICATED. TYPICAL DESIGNATION,(2#12,1#12G-1/2"C,20A-1P.)3LLPB5ON BRANCH CIRCUITRY WHERE ONLY THE CIRCUIT NUMBERIS SHOWN, CIRCUIT RECEPTACLES WITH THE SAMENUMBER TO THE CIRCUIT INDICATED WITH A HOMERUN TOEACH NUMBERED GROUP. CONNECT TO A 20A-1P CIRCUITBREAKER, OR AS NOTED FOR SPECIAL PURPOSERECEPTACLES.32B8114 ON BRANCH CIRCUITRY WHERE ONLY THE CIRCUIT NUMBERIS SHOWN, CIRCUIT LUMINAIRES WITH THE SAME NUMBERTO THE CIRCUIT INDICATED WITH A HOMERUN TO EACHNUMBERED GROUP. CONNECT TO A 20A-1P CIRCUITBREAKER, OR AS NOTED.11422DIAGRAM CIRCUIT DESIGNATION. REFER TO SCHEDULE ONDIAGRAM.2BRANCH CIRCUIT PANELBOARD. REFER TO PANEL BOARDSCHEDULE.JJUNCTION BOX3LIGHTING CONTROL SWITCH. LIGHTING WALL SWITCHES,1 POLE IF NO NOTATION. 3=3 WAY, 4=4 WAY, K=KEY TYPELOWER CASE LETTER INDICATES CONTROL DESIGNATION.OSOCCUPANCY SENSOR, CEILING MOUNTED.OSOCCUPANCY SENSOR, WALL MOUNTED.DUPLEX RECEPTACLEDOUBLE DUPLEX RECEPTACLESPECIAL PURPOSE RECEPTACLE.3INDICATION OF GANGED DEVICESLIGHTING FIXTURELIGHTING FIXTURE, WALLxxEMLIGHTING FIXTURE WITH DESIGNATION ENDING "EM "CONTAINS INTEGRAL FLUORESCENT EMERGENCY POWERUNITLIGHTING FIXTURE, FLUORESCENT STRIPEMERGENCY LIGHTING FIXTURE, INTEGRAL BATTERYEXIT LIGHT FIXTUREEXIT LIGHT FIXTURE, WALL MOUNTEDMF1EQUIPMENT CONNECTION, WITH DESIGNATION FROMELECTRIC EQUIPMENT AND CONTROL SCHEDULEF1LOCATION OF ONE OR MORE EQUIPMENT CONTROLDEVICES AS SCHEDULED ON ELECTRIC EQUIPMENT ANDCONTROL SCHEDULE. DESIGNATION REFERS TOEQUIPMENT CONTROLLEDDISCONNECT SWITCH, VOLTAGE AND AMPERE RATING TOMATCH EQUIPMENT SERVED. REFER TO ELECTRICEQUIPMENT AND CONTROL SCHEDULE.FFIRE ALARM SYSTEM, MANUAL PULL STATIONFIRE ALARM SYSTEM, THERMODETECTOR, COMBINATIONFIXED TEMPERATURE/RATE-OF-RISE, FIXED TEMPERATURERATING 135°F, UNLESS INDICATED OTHERWISE.HFIRE ALARM SYSTEM SMOKE DETECTOR. "DT" INDICATESDUCT MOUNTED TYPE WITH REMOTE TEST STATION.DTSELECTRICAL SYMBOL LISTFFFIRE ALARM SYSTEM, MAGNETIC DOOR HOLDER,INDIVIDUAL,WALL MOUNTED. SUBSCRIPT "F" INDICATESFLOOR MOUNTED.SHFIRE ALARM SYSTEM, CONNECTION TO SMOKE HATCHFSFIRE ALARM SYSTEM, CONNECTION TO SPRINKLER FLOWSWITCH. NUMBER INDICATES QUANTITYTS1-FIRE ALARM SYSTEM, CONNECTION TO SPRINKLER SYSTEMTAMPER SWITCH. NUMBER INDICATES QUANTITYPIVFIRE ALARM SYSTEM, CONNECTION TO SPRINKLER/STANDPIPE SYSTEM PIV VALVE TAMPER SWITCHTELEVISION OUTLET W/RECEPTACLE. LETTER INDICATESTYPE, NUMBER INDICATES BRANCH CIRCUIT NUMBERREFER TO DETAIL.1aTVFUSED DISCONNECT SWITCH, RATINGS AS INDICATEDSTANDARD THERMAL MAGNETIC MOLDED CASE CIRCUITBREAKER, RATINGS AS INDICATEDCTCURRENT TRANSFORMER, RATING AS INDICATEDLIGHTNING ARRESTOR, RATINGS AS INDICATEDGENERAL NOTES - ALL DRAWINGS:A.BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS,DINING ROOMS, LIVING ROOMS, BEDROOMS, CLOSETS, AND HALLWAYS SHALL BEPROTECTED BY LISTED ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION TYPECIRCUIT BREAKERS DESIGNED TO PROTECT THE BRANCH CIRCUIT PER NEC ARTICLE210.12.B.RECEPTACLES SHALL BE GFCI TYPE WHERE INSTALLED IN BATHROOMS, KITCHENSWHERE THE RECEPTACLE SERVES COUNTERTOP SURFACES, OUTDOORS, ROOFTOPS,AND WHERE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF THE OUTSIDE EDGE OF ASINK.C.UNLESS NOTED OTHERWISE, PROVIDE 15 AND 20 AMP SINGLE PHASE 120 VOLT CIRCUITCONDUCTORS AS FOLLOWS: #12 AWG FOR CIRCUITS UP TO 100 FEET LONG, #10 AWGFOR CIRCUITS 101 TO 150 FEET LONG, #8 AWG FOR CIRCUITS 151 TO 250 FEET LONG.D.PROVIDE BRANCH CIRCUITS AS FOLLOWS:* BRANCH CIRCUITS IN DWELLING UNITS OF BUILDINGS 3.2 AND 3.3 SHALL BE MC CABLE.* BRANCH CIRCUITS FOR INTERIOR HOUSE LOADS OUTSIDE OF MECHANICAL ROOMS SHALL BE MC CABLE.* BRANCH CIRCUITS IN MECHANICAL ROOMS SHALL BE IN CONDUIT.E.CIRCUIT EXIT SIGNS TOGETHER FROM 20A-1P CIRCUIT BREAKER IN PANELBOARD THATSERVES AREA LIGHTING. PROVIDE CIRCUIT BREAKER HANDLE LOCK.F.DUPLEX RECEPTACLES SHOWN IN DWELLING UNITS REPRESENT CODE REQUIREDQUANTITIES AND GENERAL SPACING PER NEC ARTICLE 210. DO NOT SCALE PLANS.VERIFY RECEPTACLE SPACING AND ADJUST LOCATIONS AS NECESSARY TO MEET NECARTICLE 210. WHERE STUD SPACING DOES NOT PERMIT NEC SPACING REQUIREMENTS,PROVIDE BRACKETS, STUDS, OR ADDITIONAL RECEPTACLES AS NECESSARY TOACHIEVE NEC ARTICLE 210 REQUIREMENTS.G.PROVIDE TAMPERPROOF RECEPTACLES FOR ALL 15 AND 20 AMP RECEPTACLES INDWELLING UNITS PER NEC ARTICLE 406.11. LOCATIONS INCLUDE ALL RECEPTACLESSPECIFIED IN NEC ARTICLE 210.52 (KITCHENS, DINING ROOMS, LIVING ROOMS,BEDROOMS, BATHROOMS, LAUNDRY AREA, CLOSETS, AND HALLWAYS).H.CIRCUIT EMERGENCY LIGHTING FIXTURES TO LOCAL AREA LIGHTING BRANCH CIRCUIT,AHEAD OF CONTROL DEVICES.I.PROVIDE NEMA 14-30R RECEPTACLE FOR EACH ELECTRIC CLOTHES DRYER ORCOMBINATION WASHER/DRYER. PROVIDE 2#10, #10N, #10G,J.PROVIDE NEMA 14-50R RECEPTACLE FOR EACH ELECTRIC RANGE. PROVIDE 2#8, #8N,#8G.K.PROVIDE 15A RECEPTACLES FOR CIRCUITS SERVED FROM 15A CIRCUIT BREAKERS INDWELLING UNITS.L.PROVIDE CONTROL FOR SITE LIGHTING AND BUILDING MOUNTED EXTERIOR LIGHTFIXTURES THROUGH MULTI-P0LE LIGHTING CONTACTORS, ASTRONOMICAL TIMESWITCH, AND ROOF MOUNTED PHOTOCELL FOR PHOTOCELL "ON" AND TIMER "OFF"CONTROL. COORDINATE TIME SWITCH SCHEDULE WITH OWNERS REPRESENTATIVE.M.PROVIDE FIRE ALARM SYSTEM WIRING COILED IN A JUNCTION BOX BEHIND A BLANKCOVER PLATE FOR DWELLING UNIT NOTIFICATION APPLIANCES NOTED AS FUTUREDEVICE.FIRE ALARM SYSTEM COMBINATION SMOKE DETECTOR ANDCO DETECTOR WITH SOUNDER BASESaDATA OUTLETSBTAMPERPROOF, GFCI, AC, DUPLEX RECEPTACLEFIRE ALARM SYSTEM SMOKE DETECTOR WITH SOUNDERBASESFIRE ALARM SYSTEM, FIRE ALARM CONTROL PANEL(S)FIRE ALARM SYSTEM, REMOTE ANNUNCIATORFIRE ALARM SYSTEM, ADDRESSABLE SMOKE DETECTORCOMMUNICATION ROOM/CLOSET GROUND BARTWCTIME WARNER CABLEFIRE ALARM SYSTEM, NOTIFICATION APPLIANCE, V=VISUALONLY, NUMBER = CANDELLA RATING, F = FUTURE DEVICE.(V,15,F)FA (15,F)FFIRE ALARM SYSTEM, NOTIFICATION APPLIANCE, HORNA=AUDIBLE ONLY, NUMBER = CANDELLA RATING FORFUTURE DEVICE.LAPFIRE ALARM SYSTEM, CONNECTION TO SPRINKLER LOW AIRPRESSURE SWITCHPSFIRE ALARM SYSTEM, CONNECTION TO SPRINKLERPRESSURE SWITCHFIRE ALARM SYSTEM, CONNECTION TO SPRINKLER ELECTRICWATER FLOW BELLFCO1-SBROOF MOUNTED PHOTOCELL CIRCUITED TO EXTERIORLIGHTING CONTACTOR AND TIME SWITCH.FIRE ALARM SYSTEM CONNECTION TO GARAGE LEVELTEMPERATURE SENSORLSIGxxx AFxxx ATMETER CENTER MAIN SERVICE CIRCUIT BREAKER,ELECTRONIC TRIP. TRIP FUNCTIONS, TRIP COIL ANDFRAME SIZE AS INDICATEDCIRCUIT BREAKER DEFINITION OF SUBSCRIPTS:LLONG TIME TRIPSSHORT TIME TRIPIINSTANTANEOUS TRIPGGROUND FAULT TRIPATTRIP COIL AMPERE RATINGAFFRAME SIZE AMPERE RATINGFIRE ALARM SYSTEM CONNECTION TO ADDRESSABLECARBON MONOXIDE DETECTORFIRE ALARM SYSTEM, NOTIFICATION APPLIANCE, V=VISUALONLY, NUMBER = CANDELLA RATING.75FDRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:COLLEGETOWNTERRACE APARTMENTSITHACA, NYNOVARR MACKESEYDEVELOPMENTPROFESSIONAL LICENSENUMBER:NEW YORK STATE SEAL:a r c h i t e c t sikon.5PROJECT NO.:P58.00VERSIONSNO.DATEDESCRIPTIONCIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICALENGINEER:LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:12923NORTHPROJECT 08'16'32'AUGUST 24, 2012107-31-2012CONSTRUCTION DOCUMENTSKEY PLANBUILDING 3BUILDING 5BUILDING 7NORTHPROJECT BUILDING 6208-24-2012SEQUENCE 2B - ISSUE FOR PERMIT FRONTAPPROXIMATE LOCATIONOF METER CENTER MC6BON LEVEL BAPPROXIMATE LOCATIONOF METER CENTER MC6AON LEVEL AAPPROXIMATE LOCATIONOF BUILDING 6 MAINCOMMUNICATION ROOMON LEVEL BTRANSFORMERT6BTRANSFORMERT6AFRONTHH-60BUILDING 6 - SITE UTILITY PLANKSOE2.011" = 20'-0"SITE UTILITY PLAN1DRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:COLLEGETOWNTERRACE APARTMENTSITHACA, NYNOVARR MACKESEYDEVELOPMENTPROFESSIONAL LICENSENUMBER:NEW YORK STATE SEAL:a r c h i t e c t sikon.5PROJECT NO.:P58.00VERSIONSNO.DATEDESCRIPTIONCIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICALENGINEER:LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:12923NORTHPROJECT AUGUST 24, 2012107-31-2012CONSTRUCTION DOCUMENTSKEY PLANBUILDING 3BUILDING 5BUILDING 7NORTHPROJECT BUILDING 6208-24-2012SEQUENCE 2B - ISSUE FOR PERMITE2.011SPP = 4" ACTIVE POWER CONDUITS = 4" SPARE CONDUITNO SCALEDUCTBANK SECTIONSPE2.013NO SCALEDUCTBANK SECTIONSSS = 4" SPARE COMMUNICATION CONDUITNOTE:A.REFER TO DUCTBANK NOTES ON THIS PLAN AND DETAILS FORDUCTBANK CONSTRUCTION REQUIREMENTS.NOTE:A.REFER TO DUCTBANK NOTES ON THIS PLAN AND DETAILS FORDUCTBANK CONSTRUCTION REQUIREMENTS.GENERAL NOTES:A.UNLESS NOTED OTHERWISE, BRANCH CIRCUITS ANDCOMMUNICATION DUCTBANK CONSTRUCTION SHALL BE DIRECTBURIED IN SAND BED.B.ELECTRIC SERVICE DUCTBANKS FROM TRANSFORMERSECONDARIES TO SERVICE ENTRANCE EQUIPMENT SHALL BEREINFORCED CONCRETE ENCASED.C.EXISTING SITE UTILITIES ARE NOT SHOWN ON THIS PLAN. REFERTO CIVIL PLANS FOR ALL SITE UTILITIES. OTHER UTILITIES MAY BEPRESENT OR PLACED IN DIFFERENT LOCATIONS. VERIFY EXACTLOCATIONS OF EXISTING UTILITIES BY TEST HOLES OR SITEINVESTIGATION BEFORE EXCAVATING. NOTIFY THEUNDERGROUND FACILITIES PROTECTION ORGANIZATION (UFPO)TO LOCATE UTILITIES BEFORE WORK COMMENCES. COORDINATEWITH CIVIL DRAWINGS.D.HAND EXCAVATE WHERE CROSSING EXISTING UTILITIES.E.PROVIDE GALVANIZED RIGID STEEL CONDUIT STUB-UPS FROM ALLPVC CONDUIT.F.CONDUIT AND DUCTBANK ROUTING IS DIAGRAMMATIC. ACTUALROUTING SHALL BE DETERMINED IN THE FIELD. PITCHDUCTBANKS AND CONDUIT AWAY FROM BUILDINGS, TOWARD PULLBOXES AND HAND HOLES.G.LOCATIONS OF PULLBOXES AND HAND HOLES ARE APPROXIMATE,FIELD VERIFY WITH CONSTRUCTION MANAGER BEFORE WORKCOMMENCES. COORDINATE WITH SITE LANDSCAPE WORK ANDOTHER UTILITY WORK.H.PROVIDE CONCRETE DUCTBANK UNDER ROADS, DRIVE LANES,PAVED SURFACES AND CONCRETE WALKS.I.PROVIDE #10 AWG CONDUCTORS FOR ALL SITE LIGHTING UNLESSNOTED OTHERWISE.KEYED NOTES:PROVIDE FIRE ALARM SYSTEM CONNECTION TO PIV TAMPERSWITCH VIA 1" CONDUIT. PROVIDE ADDRESSABLE MONITORMODULE AT LOCATION WHERE CONDUIT ENTERS THE BUILDING.PROVIDE ADDRESSABLE MONITOR MODULE FOR SITE PIV SWITCHAT CONDUIT ENTRANCE INTO BUILDING.TIME WARNERS SERVICE DUCTBANK IS PROVIDED BY TIMEWARNER AND IS CO-LOCATED IN THE NYSEG PRIMARY DUCTBANK.THE ELECTRICAL CONTRACTOR SHALL EXTEND THE TIMEWARNER DUCTS FROM APPROXIMATELY 5 FEET AHEAD OF THETRANSFORMER PRIMARY TO THE INTERIOR OF THE BUILDING,TERMINATING ADJACENT TO THE METER CENTER. MAINTAIN 48INCH CLEARANCE ABOUT THE TRANSFORMER PAD AND 12 INCHESFROM ELECTRICAL SERVICE DUCTS. TIME WARNER USES 4" PVCBUT ALSO USES 2" PVC. PROVIDE DUCT SIZE AND TYPE TO MATCHTIME WARNER DUCTS. COORDINATE ENTIRE INSTALLATION WITHTIME WARNER PRIOR TO COMMENCEMENT OF WORK. PROVIDEPULL ROPE IN ALL CONDUITS. REFER TO CIVIL PLANS FORPROPOSED NYSEG PRIMARY ROUTING.12E2.012PPP = 4" ACTIVE POWER CONDUITS = 4" SPARE CONDUITC = 4" TIME WARNER SERVICE CONDUITNO SCALEDUCTBANK SECTIONSPNOTE:A.REFER TO DUCTBANK NOTES ON THIS PLAN AND DETAILS FORDUCTBANK CONSTRUCTION REQUIREMENTS.C33 UP23456781.611.9D.11.30.AA.39.4876543211.31.5M-2M-3M-6M-7M-8M-9M-5M-4M-1M-2M-3M-6M-7M-8M-9M-5M-4M-1B.11.9B.2B.88.78.7A.99.299M-10M-10B.9BAC.1B.4C.5UP0.11.530WP75WP75WP75WP75WP75WP75WP75WP1575WP75WP75WP75WP75WP75WP75WP30WP15WP15WPTA1264METER CENTERMC6AFL2FL2FL2FL2FL2FLEM2FL2FL2FL3FL3FL3FL3FL3FLEM3FL3FL3FL3FL3FL3FLEM3FL3FL3FL3FL3FL3FL3FLEM3FL3FL3FLEM3FLEM3FL2FL2FL2FL2FL2FLEM2FL2FLEM2FL1FL2FL1FLEM2FL1FL2FL1FL2FL1FL1FL1FL1FLEM1FL1FL1FLEM1FL1FL1FLEM1FL1FLEM1FL1FZ8EM1X1E1X1X1X1X1FFEMH6B2,29FFEMFFEM14FFEM14LOADINGAREAAREAWAYAREAWAYVESTIBULEMECH RAMPUPDN234567811.9D.11.30.AA.39.4876543211.31.5M-2M-3M-6M-7M-8M-9M-5M-4M-1M-2M-3M-6M-7M-8M-9M-5M-4M-1B.11.9B.2B.2B.88.78.79.299M-10M-10B.9DCBAC.11.6B.4C.5UPDN1.50.1A.9FCP8'-5 23456781.611.39.4876543211.31.5M-2M-3M-6M-7M-8M-9M-5M-4M-1M-2M-3M-6M-7M-8M-9M-5M-4M-1DCBA9.2C.199M-10M-10D.10.AA.3B.2B.8UPDNB.4C.5UPDN8.78.7X1X1X1X1X1X1LOADCENTER T6C1LOADCENTER T6C2LOADCENTER T6C3LOADCENTER T6C4LOADCENTER T6C5LOADCENTER T6C6LOADCENTER T6C7LOADCENTER T6C8LOADCENTER T6C9LOADCENTER T6C18LOADCENTER T6C17LOADCENTER T6C16LOADCENTER T6C15LOADCENTERT6C14LOADCENTER T6C13LOADCENTER T6C12LOADCENTER T6C11LOADCENTERT6C10FEFEGFEFEFEFEGFEFEFEFEGFEFEFEFEGFEFEFEGFEFEGFEFEGFEFEGFEFEFEFEGFEELEVATORâ„– 23567811.39.487653211.3M-2M-3M-6M-7M-8M-9M-1M-2M-3M-6M-7M-8M-9M-1DCBA9.2C.199M-10M-10D.10.AA.3B.2B.8UPDN41.641.5M-5M-4M-5M-4B.4C.5UPDN8.78.7X1X1X1X1X1X1ITCLOSETD2ITCLOSETD1LOADCENTER T6D1LOADCENTER T6D2LOADCENTER T6D3LOADCENTER T6D4LOADCENTER T6D5LOADCENTER T6D6LOADCENTER T6D7LOADCENTER T6D8LOADCENTER T6D9LOADCENTER T6D18LOADCENTER T6D17LOADCENTER T6D16LOADCENTER T6D15LOADCENTERT6D14LOADCENTER T6D13LOADCENTER T6D12LOADCENTER T6D11LOADCENTERT6D10FEFEGFEFEFEFEGFEFEFEFEGFEFEFEFEGFEFEFEGFEFEGFEFEGFEFEGFEFEFEFEGFEDDDDDRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:COLLEGETOWNTERRACE APARTMENTSITHACA, NYNOVARR MACKESEYDEVELOPMENTPROFESSIONAL LICENSENUMBER:NEW YORK STATE SEAL:a r c h i t e c t sikon.5PROJECT NO.:P58.00VERSIONSNO.DATEDESCRIPTIONCIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICALENGINEER:LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:12923NORTHPROJECT 08'16'32'AUGUST 24, 2012107-31-2012CONSTRUCTION DOCUMENTSKEY PLANBUILDING 3BUILDING 5BUILDING 7NORTHPROJECT BUILDING 6208-24-2012SEQUENCE 2B - ISSUE FOR PERMITBUILDING 6 FLOOR PLAN - LEVEL DKSOE2.62D1/8"=1'-0"BUILDING 6.2 - LEVEL D112KEYED NOTES:FIRE ALARM EVACUATION SIGNAL ZONE 2.FIRE ALARM EVACUATION SIGNAL ZONE 3.CIRCUIT DESIGNATIONS REFER TO PANEL H6B2 ON LEVEL B,UNLESS NOTED OTHERWISE.CIRCUIT DESIGNATIONS REFER TO PANEL H6A1 ON LEVEL B,UNLESS NOTED OTHERWISE.CIRCUIT EXIT SIGNS ON LEVELS C AND D TOGETHER WITH #10AWG CONDUCTORS FROM A 20A-1P CIRCUIT BREAKER IN PANELH6B2. PROVIDE CIRCUIT BREAKER HANDLE LOCK.CIRCUIT EXIT SIGNS ON LEVELS C AND D TOGETHER WITH #10AWG CONDUCTORS FROM A 20A-1P CIRCUIT BREAKER IN PANELH6A1. PROVIDE CIRCUIT BREAKER HANDLE LOCK.HOMERUN TIME WARNER AND VERIZON CONDUCTORSCOMMUNICATION CLOSET D1.HOMERUN TIME WARNER AND VERIZON CONDUCTORSCOMMUNICATION CLOSET D2.VISUAL ONLY NOTIFICATION APPLIANCE CIRCUITED FROM FIREALARM EVACUATION ZONE 3.VISUAL ONLY NOTIFICATION APPLIANCE CIRCUITED FROM FIREALARM EVACUATION ZONE 2.PROVIDE THREE 4" SLEEVES THROUGH FLOOR FOR LIGHT LINK,TIME WARNER AND VERIZON CABLING.34567891011GENERAL NOTES:A.FEEDER ROUTING IS DIAGRAMMATIC. COORDINATE ROUTINGWITH OTHER TRADES AND ACTUAL FIELD CONDITIONS.B.COORDINATE IT CLOSET LAYOUTS WITH TIME WARNER CABLE ANDVERIZON. PROVIDE PLYWOOD BACKBOARD ALONG ENTIRE WALLIN EACH IT CLOSET. CORE DRILL TWO 4-INCH HOLES IN EACH ITCLOSET. 23567811.39.487653211.3M-2M-3M-6M-7M-8M-9M-1M-2M-3M-6M-7M-8M-9M-1DCBA9.2C.199M-10M-10D.10.AA.3B.2B.8UPDN41.5M-5M-441.6M-5M-48.78.7B.4C.5UPDNX1X1X1X1X1X1ITCLOSETE2ITCLOSETE1LOADCENTER T6E1LOADCENTER T6E2LOADCENTER T6E3LOADCENTER T6E4LOADCENTER T6E5LOADCENTER T6E6LOADCENTER T6E7LOADCENTER T6E8LOADCENTER T6E9LOADCENTER T6E18LOADCENTER T6E17LOADCENTER T6E16LOADCENTER T6E15LOADCENTERT6E14LOADCENTER T6E13LOADCENTER T6E12LOADCENTER T6E11LOADCENTERT6E10FEFEGFEFEFEFEGFEFEFEFEGFEFEFEFEGFEFEFEGFEFEGFEFEGFEFEGFEFEFEFEGFEELEVATORâ„– 23567811.39.487653211.3M-2M-3M-6M-7M-8M-9M-1M-2M-3M-6M-7M-8M-9M-1DCBA9.2C.199M-10M-10DND.10.AA.3B.2B.841.641.5M-5M-4M-5M-48.78.7B.4C.5DNX1X1X1X1X1X1LOADCENTER T6F1LOADCENTER T6F2LOADCENTER T6F3LOADCENTER T6F4LOADCENTER T6F5LOADCENTER T6F6LOADCENTER T6F7LOADCENTER T6F8LOADCENTER T6F9LOADCENTER T6F17LOADCENTER T6F16LOADCENTER T6F15LOADCENTERT6F14LOADCENTER T6F13LOADCENTER T6F12LOADCENTER T6F11LOADCENTERT6F10PANELH6B3PANELH6A2FEFEGFEFEFEFEGFEFEFEFEGFEFEFEFEGFEFEFEGFEFEGFEFEGFEFEGFEFEFEFEGFEELEVATORâ„– 234567811.9D.11.30.AA.3B.49.4876543211.31.5M-2M-3M-6M-7M-8M-9M-5M-4M-1M-2M-3M-6M-7M-8M-9M-5M-4M-1B.11.9B.2B.28.78.79.2C.599M-10M-10DCBAB.81.6234567811.9D.11.30.AA.3B.49.4876543211.31.5M-2M-3M-6M-7M-8M-9M-5M-4M-1M-2M-3M-6M-7M-8M-9M-5M-4M-1B.11.9B.2B.28.78.79.2C.599M-10M-10DCBAB.81.6234567811.9D.11.30.AA.3B.49.4876543211.31.5M-2M-3M-6M-7M-8M-9M-5M-4M-1M-2M-3M-6M-7M-8M-9M-5M-4M-1B.11.9B.2B.28.78.79.2C.599M-10M-10DCBAB.81.6DRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:COLLEGETOWNTERRACE APARTMENTSITHACA, NYNOVARR MACKESEYDEVELOPMENTPROFESSIONAL LICENSENUMBER:NEW YORK STATE SEAL:a r c h i t e c t sikon.5PROJECT NO.:P58.00VERSIONSNO.DATEDESCRIPTIONCIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICALENGINEER:LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:12923NORTHPROJECT 08'16'32'AUGUST 24, 2012107-31-2012CONSTRUCTION DOCUMENTSKEY PLANBUILDING 3BUILDING 5BUILDING 7NORTHPROJECT BUILDING 6208-24-2012SEQUENCE 2B - ISSUE FOR PERMITBUILDING 6 ROOF PLAN - LEVEL GKSOE2.62G1/8"=1'-0"BUILDING 6.2 - LEVEL G11KEYED NOTES:PROVIDE PHOTOCELL ON ROOF FOR CONTROL OF BUILDINGMOUNTED EXTERIOR LIGHTING AND POLE MOUNTED SITELIGHTING. CIRCUIT THROUGH TIME CLOCK AND CONTACTORS. CORRIDOR1-BED UNIT1-BED UNITCORRIDORCORRIDOR2-BED UNIT2-BED UNITCORRIDOR11313111311355559119119911911999555555555555TYPICALPANELBOARDLOCATIONRANGEDISPOSALDISHWASHERBAAA31WASHER/DRYER 17:19WASHER/DRYER 17:19WASHER/DRYER 17:19WASHER/DRYER 17:19RANGEDISPOSALDISHWASHERRANGEDISPOSALRANGEDISPOSAL111AA3AAAA33BAABBAABBA13,15DRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:COLLEGETOWNTERRACE APARTMENTSITHACA, NYNOVARR MACKESEYDEVELOPMENTPROFESSIONAL LICENSENUMBER:NEW YORK STATE SEAL:a r c h i t e c t sikon.5PROJECT NO.:P58.00VERSIONSNO.DATEDESCRIPTIONCIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICALENGINEER:LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:12923NORTHPROJECT 08'16'32'AUGUST 24, 2012107-31-2012CONSTRUCTION DOCUMENTS208-24-2012SEQUENCE 2B - ISSUE FOR PERMITENLARGED UNIT PLANSKSOE2.961/4" = 1'-0"ENLARGED UNIT PLAN 'B1'41/4" = 1'-0"ENLARGED UNIT PLAN 'B'31/4" = 1'-0"ENLARGED UNIT PLAN 'A1'21/4" = 1'-0"ENLARGED UNIT PLAN 'A'11KEYED NOTES:REFER TO FLOOR PLANS FOR EACH APARTMENT PTACDESIGNATION.PROVIDE OUTLET IN CABINET FOR KITCHEN MICROWAVE/EXHAUSTHOOD.PROVIDE AUDIBLE ONLY FIRE ALARM SYSTEM NOTIFICATIONAPPLIANCE. DEVICE LOCATION SHALL ACCOMMODATE FUTUREAUDIBLE/VISUAL DEVICE.23GENERAL NOTES:A.PROVIDE TAMPERPROOF RECEPTACLES FOR ALL 15 AND 20 AMPRECEPTACLES IN DWELLING UNITS PER NEC ARTICLE 406.11.LOCATIONS INCLUDE ALL RECEPTACLES SPECIFIED IN NECARTICLE 210.52 (KITCHENS, DINING ROOMS, LIVING ROOMS,BEDROOMS, BATHROOMS, LAUNDRY AREA, CLOSETS, ANDHALLWAYS).B.INSTALL DISPOSAL CORD AND PLUG FURNISHED BY MECHANICALCONTRACTOR. DRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:COLLEGETOWNTERRACE APARTMENTSITHACA, NYNOVARR MACKESEYDEVELOPMENTPROFESSIONAL LICENSENUMBER:NEW YORK STATE SEAL:a r c h i t e c t sikon.5PROJECT NO.:P58.00VERSIONSNO.DATEDESCRIPTIONCIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICALENGINEER:LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:12923AUGUST 24, 2012107-31-2012CONSTRUCTION DOCUMENTS208-24-2012SEQUENCE 2B - ISSUE FOR PERMITDETAILSKSOE5.01NO SACLEELEVATOR SHUTDOWN DETAIL1GENERAL NOTES:A. SHUNT TRIP WITH COIL CLEARING CONTACT RATED 24V DC.B. PROVIDE SEPARATE 20A FUSED CIRCUIT FROM FIRE ALARM PANEL FOR EACHSHUNT TRIP.C. BREAKER SIZE PER DRAWINGS - PROVIDE ACCORDING TO QUANTITY AND SIZE ORELEVATOR CIRCUITS.HOUSE PANELTO ELEVATOR HOISTWAY EQUIPMENT.REFER TO ELEVATOR DETAIL.TYPICAL FOR HEATDETECTORS LOCATED INTHE ELEVATOR PIT ANDHOISTWAY, EACHELEVATOR. WIRECONTACTS IN PARALLEL.TO MAIN FIRE ALARMPANEL (INITIATING)TO MAIN FIRE ALARMPANEL (24VDC)2#12, 1/2"COUTLET/SUPPORT BRACKET- ERICO/CADDY FASTENERSTANDARD 1 GANG, RAISEDOUTLET BOX COVERS - FORDUPLEX RECEPTACLE.GENERAL NOTES:A.FOR BACK-TO-BACK OUTLET LOCATIONS IN ADJOINING ROOMS, STAGGER BOXES LOCATION TOADJACENT CAVITIES IN WALL TO MINIMIZE SOUND TRANSMISSION.B.FROM EACH VOICE, DATA, AND TV OUTLET LOCATION, PROVIDE 3/4" MIN. SIZE EMT RACEWAY,LARGER IF REQUIRED FOR CABLE/CONNECTOR, CONCEALED IN WALL CONSTRUCTION, TO NEARESTACCESSIBLE CEILING SPACE.C.PROVIDE ALL PROVISIONS AS REQUIRED FOR A COMPLETE SYSTEM.STANDARD 1 GANG, RAISED OUTLET BOXCOVERS - FOR VOICE/DATA/TV OUTLETS.BEHIND BRACKET.STANDARD 4''SQ. x1-1\2"D. ELECTRICALBOX. TYPICAL FORVOICE, DATA, TV ANDDUPLEX RECEPTACLES.METAL STUDS-TYPICALLY 16'' o.c.LCNOMINAL 8 FOOTCEILING PLANEFA SYSTEMA/V DEVICEILLUMINATEDEXIT SIGNTOP OFPANELBOARDBACKBOXFA SYSTEMPULLSTATIONDOOR OPENINGWALL MOUNTEDINTERCOMLIGHTINGCONTROLWITHIN 6"FINISHEDFLOORELEVATIONSTANDARD COUNTER POWER,DATA, TVOR VOICE72"EQUALEQUALCOUNTERTOP80" TO BOTTOM 48"STRIKESIDE45" FOR POWER,DATA ORVOICE60"DISCONNECTSWITCH ORSTARTER1FO911AT TOP OFHOISTWAYH3548H6B1,16GFCI1KEYED NOTES:PROVIDE TWO TYPE FO LIGHT FIXTURES IN ELEVATOR SHAFT. LOCATE ONE ATBOTTOM OF SHAFT AND ONE AT LEVEL B. COORDINATE EXACT LOCATIONS WITHELEVATOR CONTRACTOR. DO NOT WIRE LIGHTS ON LOAD SIDE OF RECEPTACLE.CIRCUITRY PROVIDED BY ELEVATOR CONTRACTORHEAVY-DUTY, FUSED DISCONNECT SWITCH, COORDINATE VOLTAGE, PHASE, AND FUSESIZE WITH ELEVATOR SUPPLIER. WIRE COMPLETE TO ELEVATOR CONTROLLER.DISCONNECT SWITCH SHALL BE SHUNT TRIP TYPE. UPON ACTIVATION OF HEATDETECTOR IN HOISTWAY, SHUNT TRIP DISCONNECT SHALL OPERATE/OPEN IN ORDERTO SHUT DOWN ELEVATOR BEFORE SPRINKLERS ACTIVATE. 24V SHUNT TRIP COIL.HEAVY-DUTY, FUSED DISCONNECT SWITCH, 240 VOLT, 30 AMP (WITH 20 AMP FUSE,VERIFY WITH ELEVATOR SUPPLIER), SINGLE PHASE WITH SOLID NEUTRAL FORELEVATOR CAR LIGHTS AND VENTILATION FAN. WIRE COMPLETE TO ELEVATORCONTROLLER.HEAVY DUTY, FUSED DISCONNECT SWITCH, 240 VOLTS, 30 AMPS (WITH 20 AMP FUSE,VERIFY WITH ELEVATOR SUPPLIER), SINGLE PHASE WITH SOLID NEUTRAL FOR CARHEATING AND AIR CONDITIONING. WIRE COMPLETE TO ELEVATOR CONTROLLER.PROVIDE A 3/4" CONDUIT WITH CAT5E CABLE FROM THE MAIN TELEPHONE TERMINALBOARD TO ELEVATOR CONTROLLER.ELEVATOR FEEDER. REFER TO ELECTRIC EQUIPMENT AND CONTROL SCHEDULE.SMOKE DETECTOR LOCATED IN ELEVATOR LOBBY, ON EACH FLOOR. CONNECT TOFIRE ALARM SYSTEM AND ELEVATOR RECALL SYSTEM.SMOKE DETECTOR LOCATED AT TOP OF ELEVATOR HOISTWAY. CONNECT TO SMOKEHATCH (IF PRESENT), FIRE ALARM SYSTEM AND ELEVATOR RECALL SYSTEM.DUPLEX RECEPTACLE FOR SUMP PUMP CONTROL PANEL AND ALARM PANEL.COORDINATE LOCATION WITH PLUMBING CONTRACTOR.FIXED TEMPERATURE HEAT DETECTOR, 135°F, AT TOP OF ELEVATOR HOISTWAY.LOCATE WITHIN TWO FEET OF SPRINKLER HEAD. CONNECT TO FIRE ALARM SYSTEMAND ELEVATOR SHUTDOWN. PROVIDE CONTROL MODULES FOR SHUTDOWN.PROVIDE CONTROL MODULE, PROGRAMMING AND CONNECTION TO ELEVATOR TOFACILITATE ILLUMINATION OF ELEVATOR CAB HIGH HAT ALARM WHEN ANY FIREDETECTION DEVICE IN MACHINE ROOM OR HOISTWAY GOES INTO ALARM.PROVIDE MONITOR MODULE TO MONITOR PRESENCE OF SHUNT TRIP CONTROLPOWER. CONNECT TO FIRE ALARM SYSTEM.PROVIDE NEMA 1 CABINET WITH RELAYS FOR DESIGNATED LEVEL RECALL,ALTERNATE LEVEL RECALL, VISUAL WARNING (HIGH HAT ALARM) AND ELEVATORSHUTDOWN. LOCATE WITHIN 3 FEET OF ELEVATOR CONTROLLER. PROVIDE WIRINGCOMPLETE TO ELEVATOR CONTROLLER.1023456789GENERAL NOTES:A.LAYOUT IS GENERAL AND IS INTENDED TO SHOW ITEMS OF WORK AND NOTLOCATIONS OR SPACE CONFIGURATION. ACTUAL LOCATION OF ITEMS TO BECOORDINATED WITH ACTUAL LAYOUT OF ELEVATOR EQUIPMENT, SPACES, ANDWITH CODE ENFORCEMENT AUTHORITY HAVING JURISDICTION.B.ELEVATOR MACHINE IS LOCATED IN HOISTWAY. THERE IS NO ELEVATORMACHINE ROOM.111212H6B1,301361314ELEVATORCONTROLLER14NO SCALERECEPTACLE & VOICE/DATA/TV OUTLETSINSTALLATION @ SIDE-BY-SIDE2NO SACLEELEVATOR DETAIL (WITH BUILDING SPRINKLER SYSTEM)6NO SCALEPIT PLANCNO SCALELOBBY PLANBNO SCALESHAFT PLANANO SACLETYPICAL ROUGHING HEIGHTS FOR ELECTRIC WORK5CONDUITS TO STUB UPWITHIN LUMINAIRE BASED12" PEA GRAVEL WELLCOMPACTED. ADJUST TOALLOW PROPER BASEELEVATIONDIMENSION SCHEDULELUMINAIRETYPEDESIGNATIONUNDISTURBED EARTHABCDPER MANUFACTURERHOT DIPPED GALVANIZEDRIGID STEEL CONDUITWITH THREADEDCOUPLING. SIZE ASSHOWN ON PLANSTIE REBARS TOGETHERPROVIDE VERTICAL 4-#4REBARS AND #3HORIZONTAL REBARS 6"ON CENTERSBA1" X 45° CHAMFER ALLAROUNDCOORDINATE LUMINAIREPLATE SIZE. PROVIDE LARGERBASE IF REQUIREDWEEP SLOTREBARSC3/4" PVC GROUNDCONDUCTOR SLEEVEGROUNDING BUSHINGFINISH GRADEANCHOR BOLT CIRCLE,ORIENTATION AND PROJECTIONINSTALLED ACCORDING TOMANUFACTURER'S TEMPLATECOMPACTBACKFILL3/4" X 10'-0"GROUND RODCOMPACTBACKFILL18"COMPACTBACKFILL#2 BARECOPPERGROUNDWIRENO SCALEROUND BASEFOUNDATION DETAIL - SITE LUMINAIRES51"30"3"18"45"30"3"16"HAHBHOISTWAYBUILDINGTAJHLDUTOPOFHOISTWAYSAFETYCOMPONENTSTASJH1VFDFUSEBOXTSUABBREVIATION LIST:JH = MAIN ELEVATOR SERVICE DISCONNECT SWITCH WITH SHUNT TRIP PROVIDED BY ELECTRICALCONTRACTOR.JH1 = HOISTWAY AUXILIARY DISCONNECT SWITCH PROVIDED BY ELECTRICAL CONTRACTOR.JHS = INSPECTION AND TEST PANEL SWITCH PROVIDED BY ELEVATOR CONTRACTOR.LDU = INSPECTION AND TEST PANEL PROVIDED BY ELEVATOR CONTRACTOR.TA = 3-PHASE AUTOTRANSFORMER (208V:480V) PROVIDED BY ELEVATOR CONTRACTOR.TSU = MOTOR CONTROLLER PROVIDED BY ELEVATOR CONTRACTOR.TAS = TEST AND INSPECTION PANEL AUTOTRANSFORMER PROVIDED BY ELEVATOR CONTRACTOR.VFD = VARIABLE FREQUENCY DRIVE PROVIDED BY ELEVATOR CONTRACTOR.PDB = POWER DISTRIBUTION BLOCK PROVIDED BY ELEVATOR CONTRACTOR.M = MOTOR PROVIDED BY ELEVATOR CONTRACTOR.FUSE BOX PROVIDED BY ELEVATOR CONTRACTOR.MTOELECTRICALPANEL32227777JHJH17TOTRANSFORMERTAELEVATORFEEDERMAIN SHUNT TRIPCAR HVACCAR LIGHTS & FANSUMP PUMP CONTROLPANEL RECEPTELEV1H6B1; 20,22,24H6B1, 28H6B1, 26H6B1, 16ELEVATOR FEEDER SOURCE SCHEDULE70A3PTAJHWALL MOUNTEDSMOKE/CODETECTOR10"ELEV PIT RECEPT & LIGHTH6B1, 3010FONO SCALETYPICAL TIME WARNER SERVICE DISTRIBUTION DIAGRAMCATV SERVICEENTRANCE CABLE BYSERVICE PROVIDERTVTIMEWARNERBACKBOARDCATV SERVICEENTRANCEEQUIPMENT BYTIME WARNERTELECOMMUNICATIONS BACKBOARDGENERAL NOTES:A.PROVIDE GROUNDING PER SPECIFICATIONS AND DETAILS.B.COORDINATE ENTIRE INSTALLATION WITH TIME WARNER.C.PROVIDE ALL CABLING FROM END USER OUTLET TO TIME WARNER SERVICEEQUIPMENT. PROVIDE ALL TERMINATIONS.REFER TO FLOOR PLANSFOR QUANTITY/LOCATIONS7SKID RESISTANTSURFACEHANDHOLETYPE12" CRUSHED STONEBELOW HANDHOLE.EXTEND 6" (MIN.)AROUND OUTSIDE EDGEON HANDHOLEHHLSLOPE FINISH GRADEAWAY FROM COVER.E18"DDIMENSIONCB12"10"20"A12"DIMENSION SCHEDULEBCAEDSTAINLESS STEEL HEXHEAD BOLT WITHWASHER AND GROMMETPULL SLOTCUSTOM COVERDESIGNATION: POWER,COMMUNICATIONS, CATV,ETC.GENERAL NOTE:A.DO NOT LOCATE IN VEHICULAR TRAFFIC OR SIDEWALK AREAS.CAST POLYMERCONCRETE COVERCAST POLYMERCONCRETE BOXCAST POLYMERCONCRETE HANDHOLENO SCALEHANDHOLE DETAIL4HH34"26"23"38"40"NOTE1NOTES:1.LIGHTING HANDHOLESHHL ARE NOT SHOWN ONSITE PLANS.4-PR CAT6 UTPRG6U COAX DRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:COLLEGETOWNTERRACE APARTMENTSITHACA, NYNOVARR MACKESEYDEVELOPMENTPROFESSIONAL LICENSENUMBER:NEW YORK STATE SEAL:a r c h i t e c t sikon.5PROJECT NO.:P58.00VERSIONSNO.DATEDESCRIPTIONCIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICALENGINEER:LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:12923AUGUST 24, 2012107-31-2012CONSTRUCTION DOCUMENTS208-24-2012SEQUENCE 2B - ISSUE FOR PERMITDETAILSKSOE5.02GENERAL NOTES:A.REINFORCE WITH GRADE 60, #4 BARS @ 6" O. C. E. W.B.3/4" CHAMFER STRIP, ALL TOP EDGES INCLUDING OPENING.C.TOP AND BOTTOM TO BE SMOOTH FINISH.D.4000 PSI CONCRETE AT 28 DAYS.E.VERIFY ACTUAL REQUIRED ANCHOR BOLTS, CABLE OPENING AND OVERALL DIMENSIONSAND CONFIGURE ACCORDINGLY. COORDINATE WITH NYSEG.F.PROVIDE PAD AND INSTALLATION PER NYSEG REQUIREMENTS. SUBMIT TO NYSEG FORAPPROVAL PRIOR TO ORDERING.DIMENSIONS IN INCHES10DIMENSIONS OF POURED OR PRECAST CONCRETE PADS75-500kVA15KV3PH78A487218CBDEMIN. 1/2" COVER FORREINFORCING BARSX-FORMER RATINGFFRONTACGELIFTING LOOP,TYP.DB6"6"3"2700WEIGHTS(lbs)F1713G4 BARS @ 18" TOPONLY(TYP)TYPTYP3"NO SCALEPRECAST CONCRETE FLAT PAD8NO SACLETYPICAL SAND BED DUCTBANK DETAIL3TRENCH WIDTHCOMPACT BACKFILL TOMATCH SURROUNDINGCONDITIONSNO ROCKS, DEBRIS INBACKFILLUNLESS OTHERWISE NOTED RESTORESURFACE TO MATCH SITE CONDITIONSPROVIDE MIN. 3"CONCRETE ON ALLSIDES OF CONDUITCONDUIT: SIZE, MATERIALAND IDENTIFICATION, ASSPECIFIEDMIN. 3" BETWEEN CONDUITSTYPICAL CONDUITSPACER MAXIMUM10'-0" O.C.PROVIDE PRECAST BASEAT CONDUIT SPACERBASE, WHERE BOTTOM OFTRENCH IS NOT LEVELAND UNIFORM#4 REBARS SPIKES FORHOLD DOWN BAR. MINIMUM24" GROUND PENETRATION,DRIVEN AT AN APPROXIMATE25° ANGLE TO CONDUIT RUNHOLD DOWN BAR.PROVIDE QUANTITY TOPREVENT FLOUT-OUT,MAXIMUM 15'-0" O.C.MIN. 3" BETWEENCONDUITSCONTINUOUSMARKER TAPEGENERAL NOTES:A.REFER TO DUCTBANK SECTION AND/OR ONE-LINE DIAGRAM FOR ACTUAL QUANTITY AND SIZE OF CONDUITSREQUIRED.B.LEAVE PULL ROPE IN ALL SPARES.C.EXCAVATED MATERIAL MEETING SPECIFICATIONS MAY BE USED FOR BACKFILL IN TRENCHES. IN THE EVENTEXCAVATED MATERIAL DOES NOT MEET SPECIFICATIONS, PROVIDE GRANULAR BACKFILL AS SPECIFIED FORBACKFILL. REMOVE UNSUITABLE MATERIAL FROM SITE.D.UNLESS OTHERWISE NOTED, TOP OF CONDUIT SHALL BE 30" BELOW FINISHED GRADE.FINISH GRADENO SACLECONCRETE ENCASED DUCTBANK DETAILTYPICAL1GENERAL NOTES:A.ALLOW SUFFICIENT SLACK CABLE SO SPLICES CAN BE MADE ABOVE GRADE, OUTSIDE OFHANDHOLE. COIL SPLICE AND SLACK CABLE NEATLY INTO HANDHOLE.B.DO NOT LOCATE HANDHOLES IN VEHICULAR TRAFFIC AREAS.C.INSIDE DIMENSIONS: HT. 48 IN., WIDTH 48 IN., LENGTH 48 IN.12" OF #2 CRUSHEDSTONE; EXTENDMINIMUM OF 6" BEYONDOUTSIDE EDGE.MIN. TWO (2) COURSES BRICK.PLACE ADDITIONAL BRICK ASREQUIRED TO BRING FRAME UPTO FINISHED GRADEGROUT FRAME4" X 10" KNOCKOUTS,TWO (2) ON EACHSIDESLOPE FINISHED GRADEAWAY FROM COVERFRAME AND COVERUNDISTURBEDEARTHGRAVELREPAIR PAVING ORPLANTING TO MATCHSURROUNDINGCONDITIONSHANDHOLEFRAMEPOWERMANHOLE/PULLBOXTYPE ATYPECBBASEA33-1/2"ROUND43"32"FEG6-1/2"32"COVERXEFDCCOVERDESIGNATIONGBD30"NO SCALEPULLBOX FRAME AND COVER2NO SCALEPULL BOX DETAIL4TRENCH WIDTHCOMPACT BACKFILL TOMATCH SURROUNDINGCONDITIONSNO ROCKS, DEBRIS INBACKFILLCONDUIT: SIZE, MATERIALAND IDENTIFICATION, ASSPECIFIEDMIN. 3" BETWEEN CONDUITSTYPICAL CONDUITSPACER MAXIMUM10'-0" O.C.PROVIDE PRECAST BASEAT CONDUIT SPACERBASE, WHERE BOTTOM OFTRENCH IS NOT LEVELAND UNIFORMMIN. 3" BETWEENCONDUITSCONTINUOUSMARKER TAPEGENERAL NOTES:A.REFER TO DUCTBANK SECTION AND/OR ONE-LINE DIAGRAM FOR ACTUAL QUANTITY AND SIZE OF CONDUITSREQUIRED.B.LEAVE PULL ROPE IN ALL SPARES.C.EXCAVATED MATERIAL MEETING SPECIFICATIONS MAY BE USED FOR BACKFILL IN TRENCHES. IN THE EVENTEXCAVATED MATERIAL DOES NOT MEET SPECIFICATIONS, PROVIDE GRANULAR BACKFILL AS SPECIFIED FORBACKFILL. REMOVE UNSUITABLE MATERIAL FROM SITE.D.UNLESS OTHERWISE NOTED, TOP OF CONDUIT SHALL BE 30" BELOW FINISHED GRADE.E.SPACERS AND PRECAST BASE MAY BE DELETED FOR SINGLE TIER DUCTBANK SECTIONS.FINISH GRADEPROVIDE MIN. 3"SAND BED ON ALLSIDES OF CONDUITUNLESS OTHERWISE NOTED RESTORESURFACE TO MATCH SITE CONDITIONSTO TELCO. GROUND(IF AVAILABLE)DETAIL AGROUND GRID 2/0 CuBARE SOFT DRAWN - 19STRANDCONCRETEFOUNDATIONPRIMARYSECONDARY36"18"18"18"2/0 Cu BARE SOFTDRAWN - 19STRAND'C' TYPECOMPRESSIONCONNECTORGROUNDCLAMP8' GROUND ROD2/0 Cu BARE SOFTDRAWN - 19 STRANDGRADE12"GROUNDCLAMP8' GROUND RODPLAN VIEWSECTION VIEWDETAIL ADETAIL BNO SACLETHREE PHASE PADMOUNTED TRANSFORMERNYSEG - GROUNDING PLAN6DETAIL BGROUND RODDETAIL BDETAIL BDETAIL B18"GROUND RODGROUND RODGROUND ROD18"AX1-1/2"GENERAL NOTES:A.REPAIR ALL SETTLEMENT.B.MINIMUM TOP SOIL - 6".C.PROVIDE DIRECT BURIED INSTALLATION FOR COMMUNICATION DUCTBANKS AND POWER BRANCH CIRCUITS.D.WHERE ADDITIONAL CABLES ARE CALLED FOR, INCREASE TRENCH WIDTH AND INSTALL CABLES WITH 3"MINIMUM SPACING.E. EXCAVATED MATERIAL MEETING SPECIFICATIONS MAY BE USED FOR BACKFILL IN TRENCHES. IN THE EVENTEXCAVATED MATERIAL DOES NOT MEET SPECIFICATIONS, PROVIDE GRANULAR BACKFILL AS SPECIFIED FORBACKFILL. REMOVE UNSUITABLE MATERIAL FROM SITE.30" MINIMUM3" MINIMUM SPACINGFINISH GRADE3" SAND BEDAROUND CONDUITCOMPACT BACKFILL TOMATCH SURROUNDINGCONDITIONSNO ROCKS, DEBRIS INBACKFILLSCHEDULE 80 PVCCONDUIT UNLESSOTHERWISE SHOWNNO SACLEMULTIPLE CONDUIT DETAILTYPICAL DIRECT BURIED IN SANDBED 5PAVING OR TOPSOIL TOMATCH SITE CONDITIONSMARKING TAPEINSULATEDMOUNTINGBRACKET1/4" COPPER GROUND BARNO SCALEGROUND BAR DETAILGENERAL NOTES:A.PROVIDE #4 GREEN INSULATED GROUND WIRE TO MAIN SERVICEGROUND.B.PROVIDE GROUND BAR IN EACH COMMUNICATION ROOM/CLOSET.REFER TO FLOOR PLANS FOR LOCATIONS AND QUANTITIES.C.PROVIDE LONG BARREL, INDENT TYPE LUGS FOR GROUND CONNECTION.9SERVICEENTRANCEEQUIPMENTSTRUCTURALSTEEL#2/0 CUSERVICE ENTRANCEGROUND BUS#2/0 CUCONCRETEENCASEDELECTRODE INFLOOR SLABTYPICAL 3/4"x10'COPPERCLADGROUND RODGROUNDGRIDTYPICAL - EACHBUILDINGWATER SERVICEEXOTHERMICWELDLISTED PIPE CLAMP(WITHIN 5' OF POINT OFENTRANCE INTOBUILDING)LISTED CLAMPTYPICAL - TWOHOLECOMPRESSIONFITTING BOLTEDTO BUSTYPICAL -EXOTHERMIC WELDGENERAL NOTES:A.TYPICAL FOR ALL SERVICE ENTRANCE EQUIPMENT.B.PROVIDE SCHEDULE 80 PVC SLEEVES FOR GROUND CONDUCTORS.GROUND CLAMP HUBAND CABLE CLAMP.GROUNDING METER JUMPERAROUND WATER METER ANDINSULATING JOINTS.#4 CU#2/0 CU#4 CUCOMM ROOMGROUND BARNO SCALE BUILDINGS 6ELECTRODE SYSTEM DETAIL -7SERVICE ENTRANCE GROUNDING DRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:COLLEGETOWNTERRACE APARTMENTSITHACA, NYNOVARR MACKESEYDEVELOPMENTPROFESSIONAL LICENSENUMBER:NEW YORK STATE SEAL:a r c h i t e c t sikon.5PROJECT NO.:P58.00VERSIONSNO.DATEDESCRIPTIONCIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICALENGINEER:LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:12923AUGUST 24, 2012107-31-2012CONSTRUCTION DOCUMENTS208-24-2012SEQUENCE 2B - ISSUE FOR PERMITSCHEDULESKSOE6.01P A N E L B O A R D T Y P E A A N D A 1 S C H E D U L EA.I.C. RATING: 10,000VOLTS: 208/120VMAINS: 100ALOCATION: TYPE A AND A1BRKR SPACE: 20PHASE: 1MCB:SOURCE: METER CENTERMTG./NEMA #: 1WIRE: 3MLO: 100AFEEDER: REFER TO ONE-LINE DIAGRAM#LOADBREAKERBREAKERLOAD#TYPEDESCRIPTIONAMPPOLEPOLEAMPDESCRIPTIONTYPE1BEDROOM 1 POWER AND LIGHTING15A1120AKITCHEN POWER23120AKITCHEN POWER45LIVING ROOM LIGHTING15A1120ADISHWASHER67LIVING ROOM POWER15A1120ADISPOSAL89BATHROOM 1 POWER AND LIGHTING20A1120ARANGE HOOD/MICROWAVE1011240ARANGE1213APARTMENT PTAC UNIT15A21415SPACE1617WASHER/DRYER30A2SPACE1819SPACE20NOTE:P A N E L B O A R D T Y P E B A N D B 1 S C H E D U L EA.I.C. RATING: 10,000VOLTS: 208/120VMAINS: 100ALOCATION: TYPE B AND B1BRKR SPACE: 20PHASE: 1MCB:SOURCE: METER CENTERMTG./NEMA #: 1WIRE: 3MLO: 100AFEEDER: REFER TO ONE-LINE DIAGRAM#LOADBREAKERBREAKERLOAD#TYPEDESCRIPTIONAMPPOLEPOLEAMPDESCRIPTIONTYPE1BEDROOM 1 POWER AND LIGHTING15A1120AKITCHEN POWER23BEDROOM 2 POWER AND LIGHTING15A1120AKITCHEN POWER45LIVING ROOM LIGHTING15A1120ADISHWASHER67LIVING ROOM POWER15A1120ADISPOSAL89BATHROOM 1 POWER AND LIGHTING20A1120ARANGE HOOD/MICROWAVE1011BATHROOM 2 POWER AND LIGHTING20A1240ARANGE1213APARTMENT PTAC UNIT20A21415SPACE1617WASHER/DRYER30A2SPACE1819SPACE20NOTE: DRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:COLLEGETOWNTERRACE APARTMENTSITHACA, NYNOVARR MACKESEYDEVELOPMENTPROFESSIONAL LICENSENUMBER:NEW YORK STATE SEAL:a r c h i t e c t sikon.5PROJECT NO.:P58.00VERSIONSNO.DATEDESCRIPTIONCIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICALENGINEER:LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:12923AUGUST 24, 2012107-31-2012CONSTRUCTION DOCUMENTS208-24-2012SEQUENCE 2B - ISSUE FOR PERMITSCHEDULESKSOE6.02 DRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:COLLEGETOWNTERRACE APARTMENTSITHACA, NYNOVARR MACKESEYDEVELOPMENTPROFESSIONAL LICENSENUMBER:NEW YORK STATE SEAL:a r c h i t e c t sikon.5PROJECT NO.:P58.00VERSIONSNO.DATEDESCRIPTIONCIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICALENGINEER:LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:12923AUGUST 24, 2012107-31-2012CONSTRUCTION DOCUMENTS208-24-2012SEQUENCE 2B - ISSUE FOR PERMITSCHEDULESKSOE6.03DATA OUTLET SCHEDULETYPEMOUNTING HEIGHTNOTEA18" AFF1B18" AFF2DABOVE CEILING31TIME WARNER CABLE DATA SYSTEM. 2TIME WARNER CABLE DATA SYSTEM. COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL ELEVATION.3TIME WARNER CABLE DATA SYSTEM WIRELESS ACCESS POINT. TV OUTLET SCHEDULETV TYPEMOUNTING HEIGHTNOTEA18" AFF1NOTES:1TIME WARNER CABLE TV SYSTEM. DRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:COLLEGETOWNTERRACE APARTMENTSITHACA, NYNOVARR MACKESEYDEVELOPMENTPROFESSIONAL LICENSENUMBER:NEW YORK STATE SEAL:a r c h i t e c t sikon.5PROJECT NO.:P58.00VERSIONSNO.DATEDESCRIPTIONCIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICALENGINEER:LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:12923AUGUST 24, 2012107-31-2012CONSTRUCTION DOCUMENTS208-24-2012SEQUENCE 2B - ISSUE FOR PERMITPOWER ONE-LINE DIAGRAMKSOE7.01NO SCALEBUILDING 6 - METER CENTER MC6B - POWER ONE-LINE DIAGRAM1PAD-MOUNT TRANSFORMERBY UTILITY COMPANY.TRANSFORMER PAD BYELECTRICAL CONTRACTOR.REFER TO PAD-MOUNTEDTRANSFORMER DETAIL.REFER TO CIVILDRAWINGS FOR PRIMARYSERVICE REQUIREMENTS.7MC6A - 800A, 208/120V, 3 PHASE, 4 WIRE, 65K AIC300A3P3P3P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2PBUILDING STEELINCOMING WATER MAINGROUND BUSCONCRETE ENCASED ELECTRODE#2/0 COPPER PER NECTABLE 250.66TO ELECTRODE GROUND GRID. SEE ELECTRODEGROUND GRID DETAIL.22222222222222333344222222232233333GENERAL NOTES:A.PHASE BALANCE TENANT BREAKERS SO PHASES AB, BC, ANDCA ARE EQUALLY LOADED.B.VERIFY EXACT METER SOCKET TYPE WITH UTILITY BEFOREPROCURING EQUIPMENT.C.SCHEDULED CONDUCTORS ARE COPPER UNLESS DESIGNATEDWITH "AL" FOR ALUMINUM. REFER TO SPECIFICATIONS FORPERMITTED SUBSTITUTION OF ALUMINUM FOR COPPER .D.PROVIDE LUGS IN DISTRIBUTION EQUIPMENT TOACCOMMODATE FEEDER SIZES SHOWN. ALTERNATIVEMETHOD IS PROVIDE CABLE REDUCING PINS, OR PROVIDEJUNCTION BOX NEAR EQUIPMENT, REDUCE FEEDERS VIACOMPRESSION SPLICE TO LARGEST SIZE EQUIPMENT LUGSWILL ACCEPT.100A2P100A2P100A2P100A2P100A2P444441816100A 3P50A 3PFEEDER SCHEDULECIRCUITCONDUCTOR AND CONDUIT NOTESDESIGNATIONSIZE AND QUANTITY14#2, #8G, 1-1/4"C23#1/0, #4G, MC AL33#2/0, #4G, MC AL43#3/0, #4G, MC AL53#4/0, #2G, MC AL64#8, #10G, 3/4"C72 SETS (4#500, 4"C)84#1/0, #6G, 2"C93 SETS (4#500, 4"C)102 SETS (4"C WITH PULL ROPE)114#500, #2G, 4"C124 #3/0, #6G, 2"C134#1, #6G,1 1/2"C144#4/0, #4G, 2 1/2"C154#4/0, #2G, 2 1/2"C164#2/0, #4G, 2"C174#1/0, #4G, 2"C1819204#350, #4G, 3"C3P800ALSI DRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:COLLEGETOWNTERRACE APARTMENTSITHACA, NYNOVARR MACKESEYDEVELOPMENTPROFESSIONAL LICENSENUMBER:NEW YORK STATE SEAL:a r c h i t e c t sikon.5PROJECT NO.:P58.00VERSIONSNO.DATEDESCRIPTIONCIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICALENGINEER:LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:12923AUGUST 24, 2012107-31-2012CONSTRUCTION DOCUMENTS208-24-2012SEQUENCE 2B - ISSUE FOR PERMITPOWER ONE-LINE DIAGRAMKSOE7.02NO SCALEBUILDING 6 - METER CENTER MC6A - POWER ONE-LINE DIAGRAM1PAD-MOUNT TRANSFORMERBY UTILITY COMPANY.TRANSFORMER PAD BYELECTRICAL CONTRACTOR.REFER TO PAD-MOUNTEDTRANSFORMER DETAIL.REFER TO CIVILDRAWINGS FOR PRIMARYSERVICE REQUIREMENTS.9MC6B - 800A, 208/120V, 3 PHASE, 4 WIRE, 65K AIC225A3P3P3PSPARE2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2P100A2PBUILDING STEELINCOMING WATER MAINGROUND BUSCONCRETE ENCASED ELECTRODE#4/0 COPPER PER NECTABLE 250.66TO ELECTRODE GROUND GRID. SEE ELECTRODEGROUND GRID DETAIL.44443344222322224444334422332223P800ALSIGENERAL NOTES:A.PHASE BALANCE TENANT BREAKERS SO PHASES AB, BC, ANDCA ARE EQUALLY LOADED.B.VERIFY EXACT METER SOCKET TYPE WITH UTILITY BEFOREPROCURING EQUIPMENT.C.SCHEDULED CONDUCTORS ARE COPPER UNLESS DESIGNATEDWITH "AL" FOR ALUMINUM. REFER TO SPECIFICATIONS FORPERMITTED SUBSTITUTION OF ALUMINUM FOR COPPER .D.PROVIDE LUGS IN DISTRIBUTION EQUIPMENT TOACCOMMODATE FEEDER SIZES SHOWN. ALTERNATIVEMETHOD IS PROVIDE CABLE REDUCING PINS, OR PROVIDEJUNCTION BOX NEAR EQUIPMENT, REDUCE FEEDERS VIACOMPRESSION SPLICE TO LARGEST SIZE EQUIPMENT LUGSWILL ACCEPT.SPARE2P141100A 3PFEEDER SCHEDULECIRCUITCONDUCTOR AND CONDUIT NOTESDESIGNATIONSIZE AND QUANTITY14#2, #8G, 1-1/4"C23#1/0, #4G, MC AL33#2/0, #4G, MC AL43#3/0, #4G, MC AL53#4/0, #2G, MC AL64#8, #10G, 3/4"C72 SETS (4#500, 4"C)84#1/0, #6G, 2"C93 SETS (4#500, 4"C)102 SETS (4"C WITH PULL ROPE)114#500, #2G, 4"C124 #3/0, #6G, 2"C134#1, #6G,1 1/2"C144#4/0, #4G, 2 1/2"C154#4/0, #2G, 2 1/2"C164#2/0, #4G, 2"C174#1/0, #4G, 2"C1819204#350, #4G, 3"C DRAWING NO.:DRAWN BY:DATE:SHEET TITLE:PROJECT TITLE:COLLEGETOWNTERRACE APARTMENTSITHACA, NYNOVARR MACKESEYDEVELOPMENTPROFESSIONAL LICENSENUMBER:NEW YORK STATE SEAL:a r c h i t e c t sikon.5PROJECT NO.:P58.00VERSIONSNO.DATEDESCRIPTIONCIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICALENGINEER:LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER:12923AUGUST 24, 2012107-31-2012CONSTRUCTION DOCUMENTS208-24-2012SEQUENCE 2B - ISSUE FOR PERMITFIRE ALARM RISER DIAGRAMKSOE7.03FIRE ALARM RISER GENERAL NOTES:A.THE FIRE ALARM RISER DIAGRAM IS DIAGRAMMATIC ONLY AND IS NOTINTENDED TO SHOW EACH DEVICE, QUANTITY OF NOTIFICATIONAPPLIANCE CIRCUITS OR SIGNAL LINE CIRCUIT LOOPS, OR EXACTCONNECTIONS. OBTAIN WIRING DIAGRAM FROM SYSTEM VENDOR FORALL DEVICES AND COMPONENTS REQUIRED TO MEET SPECIFICATIONS.THE ACTUAL FIELD INSTALLATION WILL REQUIRE PULL BOXES,OFFSETS, OUTLET BOXES & OTHER RELATED ELECTRIC WORK TOPROVIDE THE PROPER INSTALLATION.B.ALL CONDUCTOR WIRING SHALL BE PERMANENTLY IDENTIFIED ANDLABELED IN ACCORDANCE WITH THE SPECIFICATIONS.C.SLC CIRCUITS: #18 TP (SHIELDED) FPL CABLE STROBE CIRCUITS (NAC): 2-#12 FPL CABLE 24VDC AUX. POWER: 2-#12 FPL CABLED.NOT ALL FIRE ALARM DEVICES ARE SHOWN OR INDICATED. DEVICESARE REPRESENTATIVE ONLY. REFER TO APPLICABLE FLOOR PLANSFOR DEVICE LOCATIONS, TYPES AND QUANTITIES.E.MAIN FIRE ALARM SIGNAL LINE CIRCUITS (SLC) WILL RUN IN HALLWAYAND IS PERMISSIBLE TO T-TAP BRANCH CIRCUITS TO EACH APARTMENTFROM MAIN CIRCUIT.KEYED NOTES:PROVIDE TWO 4-PR CAT6 TELEPHONE LINES FROM VERIZONTELEPHONE SYSTEM BACKBOARD TO FIRE ALARM CONTROL PANEL.FIRE ALARM EVACUATION SIGNAL ZONE 1FIRE ALARM EVACUATION SIGNAL ZONE 2FIRE ALARM EVACUATION SIGNAL ZONE 3PROVIDE SIGN AND VISUAL ONLY NOTIFICATION APPLIANCE AT EACHSIDE OF THE FIRE ALARM EVACUATION SIGNAL ZONE INDICATING "DONOT ENTER IF FIRE ALARM IS ACTIVATED". LOCATE SIGN ADJACENT TOTHE VISUAL ONLY NOTIFICATION APPLIANCE THAT IS ON THE ADJACENTSIGNAL LINE CIRCUIT. COORDINATE EXACT WORDING AND SIGN ANDNOTIFICATION APPLIANCE LOCATIONS WITH THE FIRE CHIEF.123FACP120V20A-1P124VDC AUX POWER24VDC AUX POWER24VDC AUX POWER24VDC AUX POWERLEVEL ALEVEL BLEVEL CLEVEL DLEVEL ELEVEL FLEVEL G24VDC AUX POWER24VDC AUX POWER24VDC AUX POWER24VDC AUX POWER4523FIRE ALARM RISER GENERAL NOTES:F. PROVIDE NAC PANELS AND TERMINAL EQUIPMENT CABINETS ASREQUIRED.G. PROVIDE FIRE ALARM SYSTEM CONNECTION TO ELEVATOR SHUNT TRIPDISCONNECT SWITCHES.H. PROVIDE ISOLATION MODULES ON SLC CLASS A CIRCUITS AT EVERYFLOOR LEVEL.5555FIRE ALARM INPUT/OUTPUT MATRIXOUTPUT ALARMFIRE ALARM3 CODE 3 CODE DOORS HOLD-TEMPORALTEMPORAL OPEN RELEASE, SUPERVISORY BUILDING WIDE SOUNDER OFF PREMISE OFF PREMISE ELEVATOR ALARM A/V'S AND ALL BASES SUPERVISORY FIRE ALARM RECALL, FANS SOUNDER WITHIN SAME ALARM SHUT DOWN, BASES DWELLING UNIT ETC.INITIATINGDEVICESMANUAL PULLXXXXSTATIONSMOKE DETECTOR/ XXXX SENSORONE (1) SOUNDER BASE MULTI-SENSOR XXX SMOKE ALGORITHMTWO (2) OR MORE SOUNDER BASE MULTI-XXXXSENSOR SMOKE ALGORITHMHEAT DETECTOR/ XXXXSENSORTAMPER SWITCHXXFLOW SWITCHXXXXLOW AIR PRESSURE XXSWITCHCARBON MONOXIDE XX (STEADY X SENSOR SOUNDER4