Loading...
HomeMy WebLinkAbout10-E7-09DRAWING NO.: DRAWN BY: DATE: SHEET TITLE: PROJECT TITLE: COLLEGETOWN TERRACE APARTMENTS ITHACA, NY NOVARR MACKESEY DEVELOPMENTPROFESSIONAL LICENSE NUMBER: NEW YORK STATE SEAL: a r c h i t e c t s ikon.5 PROJECT NO.:P58.00 VERSIONS NO. DATE DESCRIPTION CIVIL ENGINEER:STRUCTURAL ENGINEER:MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL ENGINEER: LANDSCAPE ARCHITECT:HAZARDOUS MATERIAL ENGINEER: 12923 JULY 1, 2011 1 07.01.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS KEY PLAN 2 08.10.2011 SEQUENCE 1 - CONSTRUCTION DOCUMENTS ADDENDUM - 1 NO SCALE TELEPHONE SYSTEM CABLING DIAGRAM (VERIZON)2 ELECTRICAL TELEPHONE SYSTEM DIAGRAMS FOR VERIZON SERVICE KSO E7.09 CPB-5 BUILDING 2.0 VERIZON BACKBOARD BUILDING 1 VERIZON BACKBOARD HH-1 BUILDING 4.2 VERIZON BACKBOARD BUILDING 4.1 VERIZON BACKBOARD HH-4 BUILDING 2.4 VERIZON BACKBOARD BUILDING 4.3 VERIZON BACKBOARD 1 KEYED NOTES: CAT5E TO RJ-45 OUTLET, TYPICAL. PROVIDE ONE 4-PR CAT5E TO EACH ELEVATOR AND TWO 4-PR CAT5E TO EACH FIRE ALARM CONTROL PANEL. REFER TO PLANS FOR QUANTITY AND LOCATIONS. INDICATES QUANTITY OF ELEVATORS AND FIRE ALARM PANELS IN BUILDING REFER TO VERIZON SERVICE BACKBOARD DIAGRAMS FOR GENERAL LAYOUT REQUIREMENTS. DUCTBANK AND HAND HOLES SHOWN FOR REFERENCE AND NOT USED FOR ACTIVE VERIZON SERVICE. 1 1 1 111 CPB-1 HH-5 1-FACP 0-ELEV 1-FACP 0-ELEV 1-FACP 0-ELEV 1-FACP 0-ELEV 1-FACP 0-ELEV 1-FACP 1-ELEV 2 222 2 2 2 HH-7HH-6 CPB-2CPB-3 CPB-4 HH-2 TELEPHONE CABLE SCHEDULE CIRCUIT DESIGNATION CABLE TYPE NOTES CAT5E 4-PR UTP 6 PAIR RUS PE-89 12 PAIR RUS PE-89 25 PAIR RUS PE-89 25 PAIR RUS PE-89 + 2 SETS 6 PAIR RUS PE-89 GENERAL NOTES: A. PROVIDE A MINIMUM SPARE CAPACITY OF 10 PERCENT IN THE INSTALLED PATCH PANELS. B. PROVIDE QUANTITY OF PATCH PANELS TO ACCOMMODATE ALL BUILDING FIRE ALARM CONTROL PANELS AND ELEVATOR CONTROLLERS. C. PROVIDE CABLE MANAGEMENT AND GROUNDING PER TIA/EIA STANDARDS. D. PROVIDE GROUNDING PER SPECIFICATIONS, NOT ALL GROUNDING REQUIREMENTS ARE INDICATED. VOICE PATCH 110 BLOCKS, TYPICAL CROSSOVER PROTECTED ENTRANCE TERMINAL PE-89 COPPER CABLE PER THE TELEPHONE SYSTEM CABLING DIAGRAM (VERIZON) 1 BUILDING 4.3 110 BLOCKS, TYPICAL BUILDING 4.2 110 BLOCKS, TYPICAL BUILDING 4.1 110 BLOCKS, TYPICAL BUILDING 3.3 110 BLOCKS, TYPICAL BUILDING 2.0 110 BLOCKS, TYPICAL VOICE PATCH 110 BLOCKS, TYPICAL CROSSOVER PROTECTED ENTRANCE TERMINAL 1 BUILDING 110 BLOCKS VOICE PATCH 110 BLOCKS, TYPICAL CROSSOVER PROTECTED ENTRANCE TERMINAL 1 BUILDING 2.0 110 BLOCKS, TYPICAL BUILDING 2.4 110 BLOCKS, TYPICAL BUILDING 1.0 110 BLOCKS, TYPICAL BUILDING 4.4 110 BLOCKS, TYPICAL 1 KEYED NOTES: CAT3 HORIZONTAL CABLING PROVIDE 2-PAIR FOR EACH WIRED VOICE OUTLET. NO SCALE TYPICAL FOR BUILDINGS 1.0, 2.4, 4.1 & 4.2 NO SCALE BUILDING 2.0 NO SCALE BUILDING 4.3 3 333 3 3 3 4 4 PE-89 COPPER CABLE PER THE TELEPHONE SYSTEM CABLING DIAGRAM (VERIZON) PE-89 COPPER CABLE PER THE TELEPHONE SYSTEM CABLING DIAGRAM (VERIZON) 2 2 2 2 2 2 NO SCALE VERIZON SERVICE BACKBOARD DIAGRAMS1